ENS 48967
ENS Event | |
---|---|
05:00 Apr 23, 2013 | |
Title | Agreement State Report - Failure of Radiography Source to Fully Retract |
Event Description | The following information was received from the State of Texas via E-mail:
On April 24, 2013, the Agency [Texas Department of State Health Services] was notified by the licensee that they were unable to fully retract an Iridium-192 source into a QSA model 660 radiography device. The radiographers attempted to retract the source several times, but were unable to get the device to lock the source in the fully shielded position. The radiographers contacted the Radiation Safety Officer who responded to the location along with the licensee's Source Retrieval Supervisor. The supervisor attempted to retract the source and on the second attempt, dose rates indicated that the source was fully shielded, but the device's locking device had not tripped. The supervisor inserted the source shipping plug into the device to secure the source in place. The source crankout device was dismantled and they discovered the connector on the end of the drive cable had separated from the drive cable. The crankout device has been shipped to the manufacturer for inspection and repair. The crankout device was placed in service by the licensee on April 11, 2013. The exposure device was inspected by the licensee and found to operate normally. No significant exposure was received by any individual involved in this event. Additional information will be provided in accordance with SA-300. Texas Incident #: I-9074 |
Where | |
---|---|
Metco Houston, Texas (NRC Region 4) | |
License number: | 03018 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+57.87 h2.411 days <br />0.344 weeks <br />0.0793 months <br />) | |
Opened: | Art Tucker 14:52 Apr 25, 2013 |
NRC Officer: | Donald Norwood |
Last Updated: | Apr 25, 2013 |
48967 - NRC Website | |
Metco with Agreement State | |
WEEKMONTHYEARENS 500942014-05-07T03:00:0007 May 2014 03:00:00
[Table view]Agreement State Radiography Source Tube Crimped Preventing Source Retraction ENS 489672013-04-23T05:00:00023 April 2013 05:00:00 Agreement State Agreement State Report - Failure of Radiography Source to Fully Retract ENS 484202012-10-17T05:00:00017 October 2012 05:00:00 Agreement State Agreement State Report- Unable to Retract Radiography Camera Source ENS 476762012-02-17T06:00:00017 February 2012 06:00:00 Agreement State Agreement State Report Involving Potential Radiographer Overexposure ENS 473392011-10-10T12:00:00010 October 2011 12:00:00 Agreement State Agreement State Report - Misalignment in the Crankout Device ENS 468342011-04-19T05:00:00019 April 2011 05:00:00 Agreement State Agreement State Report - Stuck Radiography Camera Source ENS 451442009-06-10T07:35:00010 June 2009 07:35:00 Agreement State Agreement State Report - Unable to Retract Radiography Source ENS 445352008-09-29T18:00:00029 September 2008 18:00:00 Agreement State Agreement State Report - Potential Overexposure to Extremities ENS 449592008-01-28T05:00:00028 January 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfuntion ENS 449632008-01-05T05:00:0005 January 2008 05:00:00 Agreement State Agreement State Report- Radiography Camera Malfunction ENS 449612007-10-18T05:00:00018 October 2007 05:00:00 Agreement State Agreement State Report - Inability to Retract Radiography Source ENS 436442007-09-15T03:00:00015 September 2007 03:00:00 Agreement State Agreement State Report Involving Potential Overexposures During Industrial Radiography ENS 434112007-05-08T05:00:0008 May 2007 05:00:00 Agreement State Agreement State Report Involving Equipment Failure of Radiography Camera 2014-05-07T03:00:00 | |