ENS 47339
ENS Event | |
---|---|
12:00 Oct 10, 2011 | |
Title | Agreement State Report - Misalignment in the Crankout Device |
Event Description | The following was received via fax:
On October 11, 2011, the Agency [state] was notified by the licensee that on October 10, 2011 while performing radiography operations in one of their shooting bays, they were unable to retract an 89 Curie Iridium - 192 source into a SPEC model 150 camera. The licensee used their video surveillance cameras to verify that nothing had fallen on the guide tube to prevent movement of the source. No obstructions were observed. A technician approved for source retrieval inspected the camera and associate equipment and determined that the crankout being used was not working correctly. The crankout was disassembled and the drive cable was pulled by hand until the source returned to the fully shielded and locked position. The licensee inspected the crankout device and found that there was a slight misalignment between the drive cable and the gear. The device was adjusted, tested and operates smoothly. The crankout device will be sent to the manufacturer for further evaluation. No additional exposure was received by any individual during this event. Texas Incident No. I-8890 |
Where | |
---|---|
Metco Houston, Texas (NRC Region 4) | |
License number: | 03018 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+44.5 h1.854 days <br />0.265 weeks <br />0.061 months <br />) | |
Opened: | Art Tucker 08:30 Oct 12, 2011 |
NRC Officer: | Joe O'Hara |
Last Updated: | Oct 12, 2011 |
47339 - NRC Website | |
Metco with Agreement State | |
WEEKMONTHYEARENS 500942014-05-07T03:00:0007 May 2014 03:00:00
[Table view]Agreement State Radiography Source Tube Crimped Preventing Source Retraction ENS 489672013-04-23T05:00:00023 April 2013 05:00:00 Agreement State Agreement State Report - Failure of Radiography Source to Fully Retract ENS 484202012-10-17T05:00:00017 October 2012 05:00:00 Agreement State Agreement State Report- Unable to Retract Radiography Camera Source ENS 476762012-02-17T06:00:00017 February 2012 06:00:00 Agreement State Agreement State Report Involving Potential Radiographer Overexposure ENS 473392011-10-10T12:00:00010 October 2011 12:00:00 Agreement State Agreement State Report - Misalignment in the Crankout Device ENS 468342011-04-19T05:00:00019 April 2011 05:00:00 Agreement State Agreement State Report - Stuck Radiography Camera Source ENS 451442009-06-10T07:35:00010 June 2009 07:35:00 Agreement State Agreement State Report - Unable to Retract Radiography Source ENS 445352008-09-29T18:00:00029 September 2008 18:00:00 Agreement State Agreement State Report - Potential Overexposure to Extremities ENS 449592008-01-28T05:00:00028 January 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfuntion ENS 449632008-01-05T05:00:0005 January 2008 05:00:00 Agreement State Agreement State Report- Radiography Camera Malfunction ENS 449612007-10-18T05:00:00018 October 2007 05:00:00 Agreement State Agreement State Report - Inability to Retract Radiography Source ENS 436442007-09-15T03:00:00015 September 2007 03:00:00 Agreement State Agreement State Report Involving Potential Overexposures During Industrial Radiography ENS 434112007-05-08T05:00:0008 May 2007 05:00:00 Agreement State Agreement State Report Involving Equipment Failure of Radiography Camera 2014-05-07T03:00:00 | |