ENS 48420
ENS Event | |
---|---|
05:00 Oct 17, 2012 | |
Title | Agreement State Report- Unable to Retract Radiography Camera Source |
Event Description | The following information was received by email:
On October 18, 2012, the Agency [Texas Radiation Branch] was notified by the licensee that on October 17, 2012, a radiographer was unable to retract a [source] into the QSA 880F exposure device. The guide tube for the device was damaged during radiography operation in the fixed facility when a part fell on it, crimping the guide tube to a point where the source could not pass through it. The licensee stated that they were able to repair the guide tube enough to retract the source and lock it in the exposure device. The licensee stated that no over exposure occurred from the event and no member of the general public received any exposure from the event. Additional information will be provided as it is received in accordance with SA 300. Texas Incident: I-8998 |
Where | |
---|---|
Metco Houston, Texas (NRC Region 4) | |
License number: | 03018 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+35.93 h1.497 days <br />0.214 weeks <br />0.0492 months <br />) | |
Opened: | Art Tucker 16:56 Oct 18, 2012 |
NRC Officer: | Vince Klco |
Last Updated: | Oct 18, 2012 |
48420 - NRC Website | |
Metco with Agreement State | |
WEEKMONTHYEARENS 500942014-05-07T03:00:0007 May 2014 03:00:00
[Table view]Agreement State Radiography Source Tube Crimped Preventing Source Retraction ENS 489672013-04-23T05:00:00023 April 2013 05:00:00 Agreement State Agreement State Report - Failure of Radiography Source to Fully Retract ENS 484202012-10-17T05:00:00017 October 2012 05:00:00 Agreement State Agreement State Report- Unable to Retract Radiography Camera Source ENS 476762012-02-17T06:00:00017 February 2012 06:00:00 Agreement State Agreement State Report Involving Potential Radiographer Overexposure ENS 473392011-10-10T12:00:00010 October 2011 12:00:00 Agreement State Agreement State Report - Misalignment in the Crankout Device ENS 468342011-04-19T05:00:00019 April 2011 05:00:00 Agreement State Agreement State Report - Stuck Radiography Camera Source ENS 451442009-06-10T07:35:00010 June 2009 07:35:00 Agreement State Agreement State Report - Unable to Retract Radiography Source ENS 445352008-09-29T18:00:00029 September 2008 18:00:00 Agreement State Agreement State Report - Potential Overexposure to Extremities ENS 449592008-01-28T05:00:00028 January 2008 05:00:00 Agreement State Agreement State Report - Radiography Camera Malfuntion ENS 449632008-01-05T05:00:0005 January 2008 05:00:00 Agreement State Agreement State Report- Radiography Camera Malfunction ENS 449612007-10-18T05:00:00018 October 2007 05:00:00 Agreement State Agreement State Report - Inability to Retract Radiography Source ENS 436442007-09-15T03:00:00015 September 2007 03:00:00 Agreement State Agreement State Report Involving Potential Overexposures During Industrial Radiography ENS 434112007-05-08T05:00:0008 May 2007 05:00:00 Agreement State Agreement State Report Involving Equipment Failure of Radiography Camera 2014-05-07T03:00:00 | |