ML14196A419

From kanterella
Revision as of 12:24, 1 July 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
TSTF Handout from 7/10/14 Meeting Draft Secondary Containment TS Markup
ML14196A419
Person / Time
Site: Technical Specifications Task Force
Issue date: 07/07/2014
From: Mann A
- No Known Affiliation
To:
Shared Package
ML14196A409 List:
References
Download: ML14196A419 (4)


Text


NOTE-------------------------------------------- Momentary transients above the [secondary] containment pressure limit are permitted.


, except when the access opening is being used for entry and exit