ML15205A318
ML15205A318 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 07/16/2015 |
From: | Harding T Exelon Generation Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
WPLNRC-10002985 | |
Download: ML15205A318 (4) | |
Text
wf-Exelon Generation..R.E. Ginna Nuclear Power Plant1503 Lake Rd.Ontario, NY 14519www.exeloncorp.comJuly 16, 201510 CFR 50 Appendix EU.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 2055-0001R.E. Ginna Nuclear Power PlantFacility Operating License No. DPR- 18NRC Docket No. 50-244
Subject:
ERDS Data Point Library UpdateIn accordance with 10 CFR 50 Appendix E, Emergency Planning and Preparedness for Productionand Utilization Facilities,Section VI, Emergency Response Data System, paragraph 3.a, andNUREG-1394, Emergency Response Data System (ERDS) Implementation, revision 1 Section 3.6,Administrative Implementation Requirements, the R.E. Ginna Nuclear Power Plant is providing anupdate to the ERDS Data Point Library (DPL). The changes are included in Attachment 1.There are no regulatory commitments contained in this letter.Should you have any questions regarding this submittal, please contact Thomas Harding at 315-791-5219.Respectfully,Thomas HardingManager, Regulatory AssuranceR.E. Ginna Nuclear Power Plant, LLCTH/kc
Attachment:
(1) ERDS Data Point Library Updatecc:NRC Regional Administrator, Region INRC Project Manager, GinnaNRC Resident Inspector, GinnaA "~'~(~JPLN~(-~/ ~Cc9q8 Attachment (1)ERDS Data Point Library Update 1)2)3)4)5)6)7)8)9)10)11)12)13)14)15)16)17)18)19)20)21)22)23)24)25)Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Plant Point ID:Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:Engineering Units or Digital States:Engineering Units Conversion:Minimum Instrument Range:Maximum Instrument Range:Zero Point
Reference:
Reference Point Notes:Process or Sensor:Number of Sensors:How Processed:Sensor Locations:Alarm/Trip Setpoints:NI Detector Power Supply Cut-Off PoNI Detector Power Supply Turn-On PInstrument Failure Mode:Temperature Compensation for DP TLevel Reference Leg:Unique System
Description:
EP-20150709-00002ERDS DATA POINT LIBRARY Da6/19/15GIl (Ginna)N/ASTAB CLASSWT150150 FOOT LEVEL TEMPERATUREAIR STABILITY AT REACTOR SITEANALOGDEGFN/A-20 F120 FN/AN/ASENSOR1N/AMET TOWER NORTHWEST OF PLANTN/A3wer Level: N/Asower Level: N/AN/A*ransmitters: N/AN/AN/Atapoint 63 of 64 1)2)3)4)5)6)7)8)9)10)11)12)13)14)15)16)17)18)19)20)21)22)23)24)25)Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Plant Point ID:Plant Specific Point
Description:
Generic/Condensed
Description:
Analog/Digital:Engineering Units or Digital States:Engineering Units Conversion:Minimum Instrument Range:Maximum Instrument Range:Zero Point
Reference:
Reference Point Notes:Process or Sensor:Number of Sensors:How Processed:Sensor Locations:Alarm/Trip Setpoints:NI Detector Power Supply Cut-Off PoNI Detector Power Supply Turn-On PInstrument Failure Mode:Temperature Compensation for DP TLevel Reference Leg:Unique System
Description:
EP-20150709-00003ERDS DATA POINT LIBRARY Da6/19/15Gil (Ginna)N/ASTAB CLASSWDT1150 TO 33 FOOT LEVEL DELTA TEMPAIR STABILITY AT REACTOR SITEANALOGDEGFN/A-10 F10FN/AN/APROCESS2D/FMET TOWER NORTHWEST OF PLANTN/Awer Level: N/Aower Level: N/AN/Aransmitters: N/AN/AA: <-1.17FB: > -1.17F and < -1.05FC: > -1.05F and < -0.94FD: > -0.94F and < -0.35FE: > -0.35F and < +0.94FF: > +0.94F and < +2.57FG: > +2.57Ftapoint 64 of 64