| #REDIRECT [[05000281/LER-1992-001, Forwards Corrected Page 3 to LER 92-001-00,correcting Date from 910128 to 920228]]
| | {{Adams |
| | | number = ML20094M733 |
| | | issue date = 03/26/1992 |
| | | title = Corrected Page 3 to LER 92-001-00 Re 920130 Mechanical Failure Due to Oil Leak from Charging Pump a Bearing & Damper Remaining Closed on Charging Pump B |
| | | author name = |
| | | author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| | | addressee name = |
| | | addressee affiliation = |
| | | docket = 05000281 |
| | | license number = |
| | | contact person = |
| | | document report number = LER-92-001-04, LER-92-1-4, NUDOCS 9204010320 |
| | | package number = ML18153C951 |
| | | document type = LICENSEE EVENT REPORT (SEE ALSO AO RO), TEXT-SAFETY REPORT |
| | | page count = 1 |
| | }} |
| | {{LER |
| | | Title = Corrected Page 3 to LER 92-001-00 Re 920130 Mechanical Failure Due to Oil Leak from Charging Pump a Bearing & Damper Remaining Closed on Charging Pump B |
| | | Plant = |
| | | Reporting criterion = |
| | | Power level = |
| | | Mode = |
| | | Docket = 05000281 |
| | | LER year = 1992 |
| | | LER number = 1 |
| | | LER revision = 0 |
| | | Event date = |
| | | Report date = |
| | | ENS = |
| | | abstract = |
| | }} |
| | |
| | =text= |
| | {{#Wiki_filter:2 NIC FDAM 3enA U S NUC4 tan ALGULATDJIY COhmultiON APPRovlD OWS NO 3160 0104 p |
| | i RFlht $ 4!30'92 LICENSEE EVENT REPOPT (LEFI) |
| | "'s, ^4',tl Aug,p,"nt'225',,,'%f '",y,*n'," 1",a TEXT CONTINUATlON f4%",t,';.'a',T'A,MiZi'Ait'J"'/!d 'u",'"',8f"fA "la"l&9"'s?","AWGA*Mnn%2 D?,'a DF MANAGEME NT AND puDLET, W A&HiNG TON DC Av!gi) |
| | W' KIT Y N AMt til DOCA t t NUMet R 421 ggg gggggggg, p,,gg g31 vtan sa cwt % v.a t at s mio% |
| | Sarry Nwor Stat f on, Unit. 2 ol5l0l0l0[2l8l1 9l 2 ol0 l 1 |
| | :- 0l0 0l3 or 0l4 rw w - em. e o.e,-.< a, ea me nn. ww.nn, 2.0 SIGNIFICANT SAFETY CONSEOUENCES AND IMPLICATIONS The charging pumps provide makeup and seal water injection flow to the Reactor Coolant :'ystem during normal operation and also serve a: |
| | high head safety it.)c W pumps in a design bar.5 accident. |
| | Three charging pumps are pm n&d. |
| | Each pump can provhie 100% of normal j |
| | charging or design high ht ad safety injection flow. |
| | The pumps were not fully operable in accordance with the definition in Technical y |
| | Specification 1.0.D. |
| | Ilowever, either the "A" or "B" chr 4 ng pump was 3 |
| | capable of performing its high head safety injec' ion function during a design basis accident until the "C" charging pump could be placed in service. |
| | Engineering calculations performed previously for Station Blackout indicate that a charging pump could nn while its associated damper was cined for up to four hours. |
| | Thrrefore, the accident design basis assumptions would have been satisfied and no actual or potential consequences to public health and safety were created by the event. |
| | ? |
| | 2 3.0 CAUSE OF TIIE EVENT The January 30, 1992 evem was caused by mechanical failure due to an oil leak from the "A" |
| | .;harging pump bearing and th. |
| | damper remaining closed on the "B" |
| | charging pump. |
| | The failure cf the dsmper resulted from human error due to a procedural deficiency and weakness in training on the manual operation of the damper. |
| | On January 28, 1992 testing had been performed on the Emergency Ventiation System. |
| | This testing required the charging pump ventilation damper (2-VS-MOD-201B) for the "B" charging pump to be de cnergized and the handwheel manually depressed. |
| | The charging pump ventilation dampers are equipped with a manual cut off switch which is actuated when the handwheel is depressed for manual operation. |
| | The cut-off switch prevents injury due to unexpected restoration of power and is automatically reset when the handwheel is returned to the raised position. |
| | It was concluded that the handwheel was left in the manual position upon completion of the testing. |
| | The manual operation of the damper is infrequently performed and not covered by a procedure, in addition, the operator training program does not provide training on this feature. |
| | 4.0 IMMEDI ATE CORRECI1YLACTION(S) |
| | Troubicshooting by on shift Operations and Maintenance personnel determined that the handwheel on the operator for damper 2 VS-MOD-20 lf! |
| | was aepressed for manual operation which prevented the 9204010320 920326 PDR ADOCK 05000281 S |
| | PDR NMC Penn 344A (6491 x- |
| | }} |
| | |
| | {{LER-Nav}} |
Similar Documents at Surry |
|---|
|
LER-1992-001, Corrected Page 3 to LER 92-001-00 Re 920130 Mechanical Failure Due to Oil Leak from Charging Pump a Bearing & Damper Remaining Closed on Charging Pump B |
| Event date: |
|
|---|
| Report date: |
|
|---|
| 2811992001R00 - NRC Website |
|
text
2 NIC FDAM 3enA U S NUC4 tan ALGULATDJIY COhmultiON APPRovlD OWS NO 3160 0104 p
i RFlht $ 4!30'92 LICENSEE EVENT REPOPT (LEFI)
"'s, ^4',tl Aug,p,"nt'225',,,'%f '",y,*n'," 1",a TEXT CONTINUATlON f4%",t,';.'a',T'A,MiZi'Ait'J"'/!d 'u",'"',8f"fA "la"l&9"'s?","AWGA*Mnn%2 D?,'a DF MANAGEME NT AND puDLET, W A&HiNG TON DC Av!gi)
W' KIT Y N AMt til DOCA t t NUMet R 421 ggg gggggggg, p,,gg g31 vtan sa cwt % v.a t at s mio%
Sarry Nwor Stat f on, Unit. 2 ol5l0l0l0[2l8l1 9l 2 ol0 l 1
- - 0l0 0l3 or 0l4 rw w - em. e o.e,-.< a, ea me nn. ww.nn, 2.0 SIGNIFICANT SAFETY CONSEOUENCES AND IMPLICATIONS The charging pumps provide makeup and seal water injection flow to the Reactor Coolant :'ystem during normal operation and also serve a:
high head safety it.)c W pumps in a design bar.5 accident.
Three charging pumps are pm n&d.
Each pump can provhie 100% of normal j
charging or design high ht ad safety injection flow.
The pumps were not fully operable in accordance with the definition in Technical y
Specification 1.0.D.
Ilowever, either the "A" or "B" chr 4 ng pump was 3
capable of performing its high head safety injec' ion function during a design basis accident until the "C" charging pump could be placed in service.
Engineering calculations performed previously for Station Blackout indicate that a charging pump could nn while its associated damper was cined for up to four hours.
Thrrefore, the accident design basis assumptions would have been satisfied and no actual or potential consequences to public health and safety were created by the event.
?
2 3.0 CAUSE OF TIIE EVENT The January 30, 1992 evem was caused by mechanical failure due to an oil leak from the "A"
.;harging pump bearing and th.
damper remaining closed on the "B"
charging pump.
The failure cf the dsmper resulted from human error due to a procedural deficiency and weakness in training on the manual operation of the damper.
On January 28, 1992 testing had been performed on the Emergency Ventiation System.
This testing required the charging pump ventilation damper (2-VS-MOD-201B) for the "B" charging pump to be de cnergized and the handwheel manually depressed.
The charging pump ventilation dampers are equipped with a manual cut off switch which is actuated when the handwheel is depressed for manual operation.
The cut-off switch prevents injury due to unexpected restoration of power and is automatically reset when the handwheel is returned to the raised position.
It was concluded that the handwheel was left in the manual position upon completion of the testing.
The manual operation of the damper is infrequently performed and not covered by a procedure, in addition, the operator training program does not provide training on this feature.
4.0 IMMEDI ATE CORRECI1YLACTION(S)
Troubicshooting by on shift Operations and Maintenance personnel determined that the handwheel on the operator for damper 2 VS-MOD-20 lf!
was aepressed for manual operation which prevented the 9204010320 920326 PDR ADOCK 05000281 S
PDR NMC Penn 344A (6491 x-
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000281/LER-1992-001-03, :on 920130,charging Pump 2-CH-P-1A Declared Inoperable Due to Oil Leak & Ventilation Damper for Charging Pump B Cubicle Failed to Open.Caused by Mechanical Failure/Personnel Error.Pump Repaired |
- on 920130,charging Pump 2-CH-P-1A Declared Inoperable Due to Oil Leak & Ventilation Damper for Charging Pump B Cubicle Failed to Open.Caused by Mechanical Failure/Personnel Error.Pump Repaired
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000281/LER-1992-001, Corrected Page 3 to LER 92-001-00 Re 920130 Mechanical Failure Due to Oil Leak from Charging Pump a Bearing & Damper Remaining Closed on Charging Pump B | Corrected Page 3 to LER 92-001-00 Re 920130 Mechanical Failure Due to Oil Leak from Charging Pump a Bearing & Damper Remaining Closed on Charging Pump B | | | 05000280/LER-1992-001, :on 920102,during Control Rod Freedom of Movement Test,Rod H-2 Dropped Due to Personnel Error.Control Rod H-2 Verified to Be in Core by Observing Skewed Core Power Distribution |
- on 920102,during Control Rod Freedom of Movement Test,Rod H-2 Dropped Due to Personnel Error.Control Rod H-2 Verified to Be in Core by Observing Skewed Core Power Distribution
| 10 CFR 50.73(a)(2)(i) | | 05000280/LER-1992-002, On 920106,4160 Volt Transfer Buses D,E & F UV Relay Trip Setpoints Set Below TS Limits.Caused by Calibr Process Error.Relays Recalibr & Set to More Conservative Values than Required | On 920106,4160 Volt Transfer Buses D,E & F UV Relay Trip Setpoints Set Below TS Limits.Caused by Calibr Process Error.Relays Recalibr & Set to More Conservative Values than Required | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000281/LER-1992-002-03, :on 920227,two Charging Pumps & One Charging Pump Svc Water Pump Removed from Svc Simultaneously.Caused by Congnitive Personnel Error.Senior Reactor Operator Disciplined & Pump Returned to Svc |
- on 920227,two Charging Pumps & One Charging Pump Svc Water Pump Removed from Svc Simultaneously.Caused by Congnitive Personnel Error.Senior Reactor Operator Disciplined & Pump Returned to Svc
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000280/LER-1992-003, :on 920214,determined That Certain ESF Sys Logic Acutation Relays Not Fully Tested Per Ts.Caused by Inadequate Testing Methodology.Surveillance Procedures for Channel Functional Test Changed |
- on 920214,determined That Certain ESF Sys Logic Acutation Relays Not Fully Tested Per Ts.Caused by Inadequate Testing Methodology.Surveillance Procedures for Channel Functional Test Changed
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2) | | 05000281/LER-1992-003-03, :on 920325,main Cr/Emergency Switchgear Room Chiller Was Declared Inoperable Due to High Svc Water Differential Pressure & Inoperable Emergency Power Source. Svc Water Differential Pressure Restored |
- on 920325,main Cr/Emergency Switchgear Room Chiller Was Declared Inoperable Due to High Svc Water Differential Pressure & Inoperable Emergency Power Source. Svc Water Differential Pressure Restored
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000280/LER-1992-003-01, :on 920214,incomplete Engineered Safety Features Testing Due to Procedure Deficiency.Testing Procedures Were Changed & Actuation Testing of Low RCS Average Temp Relays Performed Satisfactorily |
- on 920214,incomplete Engineered Safety Features Testing Due to Procedure Deficiency.Testing Procedures Were Changed & Actuation Testing of Low RCS Average Temp Relays Performed Satisfactorily
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000281/LER-1992-004-02, :on 920326,B Chiller Became Inoperable Due to Hand Operated Rocker Switch Inadvertently Being Placed in Off Position.Chiller Returned to Svc.Upgrade to Sys Will Include Installation of Two Chillers |
- on 920326,B Chiller Became Inoperable Due to Hand Operated Rocker Switch Inadvertently Being Placed in Off Position.Chiller Returned to Svc.Upgrade to Sys Will Include Installation of Two Chillers
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(o)(2) | | 05000280/LER-1992-004-03, :on 920318,EDG 3 Automatically Started Upon Receipt of Unit 1 Volt Emergency Bus Undervoltage Signal. Caused by Personnel Error.Human Performance Enhancement Sys Evaluation Being Conducted |
- on 920318,EDG 3 Automatically Started Upon Receipt of Unit 1 Volt Emergency Bus Undervoltage Signal. Caused by Personnel Error.Human Performance Enhancement Sys Evaluation Being Conducted
| 10 CFR 50.73(a)(2)(iv), System Actuation | | 05000281/LER-1992-005-03, :on 920410,one Train of Intake Canal Level Sensing Channel 1 Discovered Out of Trip Position After Isolation Screenwell.Cause Not Determined.No Corrective Actions Necessary |
- on 920410,one Train of Intake Canal Level Sensing Channel 1 Discovered Out of Trip Position After Isolation Screenwell.Cause Not Determined.No Corrective Actions Necessary
| 10 CFR 50.73(a)(2)(i) | | 05000280/LER-1992-005-02, :on 920402,determined That Refueling Containment Integrity Did Not Exist Since Secondary Side of SG B Open for Sludge Lancing.Caused by Inadequate Procedures.Bonnet Reinstalled on Check Valve |
- on 920402,determined That Refueling Containment Integrity Did Not Exist Since Secondary Side of SG B Open for Sludge Lancing.Caused by Inadequate Procedures.Bonnet Reinstalled on Check Valve
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) | | 05000280/LER-1992-006-03, :on 920419,filter Exhaust Fan 1-VS-F-58B Tripped Due to Excessive Vacuum.Caused by Auxiliary Ventilation Exhaust Filter Sys Train B Filters Being Near End of Svc Life.Fan Was Restarted |
- on 920419,filter Exhaust Fan 1-VS-F-58B Tripped Due to Excessive Vacuum.Caused by Auxiliary Ventilation Exhaust Filter Sys Train B Filters Being Near End of Svc Life.Fan Was Restarted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000280/LER-1992-006-02, :on 920424,determined That Three Snubbers Did Not Satisfy One Acceptance Criteria of TS 4.17.E.1a. Caused by Personnel Error.No Immediate Action Necessary |
- on 920424,determined That Three Snubbers Did Not Satisfy One Acceptance Criteria of TS 4.17.E.1a. Caused by Personnel Error.No Immediate Action Necessary
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000280/LER-1992-007-01, :on 920507,reactor Tripped Due to Contract Personnel Performing Unauthorized Turbine Maint.Unit Stabilized Following Trip.Contract Personnel Debriefed & Asked to Leave Site |
- on 920507,reactor Tripped Due to Contract Personnel Performing Unauthorized Turbine Maint.Unit Stabilized Following Trip.Contract Personnel Debriefed & Asked to Leave Site
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) | | 05000281/LER-1992-007-02, :on 920615,portion of AFW Sys Full Flow Recirculation Line Was Uncovered During Excavation Work. Caused by Personnel Error.Soil Promptly Replaced Restoring Missile Protection Qualification of Line |
- on 920615,portion of AFW Sys Full Flow Recirculation Line Was Uncovered During Excavation Work. Caused by Personnel Error.Soil Promptly Replaced Restoring Missile Protection Qualification of Line
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000280/LER-1992-008-02, :on 920511,noted That Unit 1 HHSI Pump Configuration Plant Design Basis Inadequate Due to Procedure Change Implementation.Unit 1 HHSI Pumps Realigned |
- on 920511,noted That Unit 1 HHSI Pump Configuration Plant Design Basis Inadequate Due to Procedure Change Implementation.Unit 1 HHSI Pumps Realigned
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000281/LER-1992-008-03, :on 921215,RCS Leak Identified Near Low Pressure Letdown Flow Transmitter.Caused by Failure of Swagelock Fitting on Flow Transmitter.Root Cause Evaluation in Progress & Fitting & Tube Replaced |
- on 921215,RCS Leak Identified Near Low Pressure Letdown Flow Transmitter.Caused by Failure of Swagelock Fitting on Flow Transmitter.Root Cause Evaluation in Progress & Fitting & Tube Replaced
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000280/LER-1992-009-01, :on 920712 & 27,two of Three Mcr/Esgr Chillers Became Inoperable.Caused by Insufficient Svc Water Flow to Chiller Condensers Due to Fouling of Y-type Strainers. Suction Strainer Cleaned,Per GL 89-13 |
- on 920712 & 27,two of Three Mcr/Esgr Chillers Became Inoperable.Caused by Insufficient Svc Water Flow to Chiller Condensers Due to Fouling of Y-type Strainers. Suction Strainer Cleaned,Per GL 89-13
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2) | | 05000281/LER-1992-009-02, :on 920713,automatic ESF Actuation Signal Occurred,Causing Auxiliary Feedwater Sys motor-operated Valves to Receive Open Signal.Caused by Failure of 25A9 Breaker to Trip.Svc Water Leak Isolated |
- on 920713,automatic ESF Actuation Signal Occurred,Causing Auxiliary Feedwater Sys motor-operated Valves to Receive Open Signal.Caused by Failure of 25A9 Breaker to Trip.Svc Water Leak Isolated
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) | | 05000281/LER-1992-010-02, :on 920917,TDAFWA Pump Automatically Started Due to Relay Failure in Station Svc UV Portion of AFW Start Circuit.Failed Agastat Relay Being Analyzed to Determine Cause.Relay Replaced & Satisfactorily Tested |
- on 920917,TDAFWA Pump Automatically Started Due to Relay Failure in Station Svc UV Portion of AFW Start Circuit.Failed Agastat Relay Being Analyzed to Determine Cause.Relay Replaced & Satisfactorily Tested
| 10 CFR 50.73(a)(2)(iv), System Actuation | | 05000280/LER-1992-011-02, :on 920921,discovered That TS Requirements for Low Pressure Carbon Dioxide Fire Protection Sys Nozzles Not Correctly Performed.Caused by Procedure Deficiency & Lack of Continuous Fire Watch.Watch Reestablished |
- on 920921,discovered That TS Requirements for Low Pressure Carbon Dioxide Fire Protection Sys Nozzles Not Correctly Performed.Caused by Procedure Deficiency & Lack of Continuous Fire Watch.Watch Reestablished
| |
|