WORK ABSTRACT The Site Modifications Group is responsible for preparing Work Orders (work packages) for fabrication and installation of design changes in accordance with ASME Section XI and the National Board Inspection Code. This work is documented on NIS-2 Forms, or on R-1 Forms, which are submitted herewith.
WORK ABSTRACT The Site Modifications Group is responsible for preparing Work Orders (work packages) for fabrication and installation of design changes in accordance with ASME Section XI and the National Board Inspection Code. This work is documented on NIS-2 Forms, or on R-1 Forms, which are submitted herewith.
MODIFICATION INSTALLATION GROUP Design Change Packages for ASME Section Xl ( Class 1, 2 and 3), and the National Board Inspection Code, installed in Unit 1 since the completion of the Eleventh Refueling Outage through completion of theTwelfth Refueling Outage are summarized below:
MODIFICATION INSTALLATION GROUP Design Change Packages for ASME Section Xl ( Class 1, 2 and 3), and the National Board Inspection Code, installed in Unit 1 since the completion of the Eleventh Refueling Outage through completion of theTwelfth Refueling Outage are summarized below:
DESIGN CHANGE             SYSTEM / CLASS PACKAGE                                           DESCRIPTION NUMBER 97-9100D, F and G               024A III         Replaced Fuel Oil Day Tank level transmitters 179458                           145AI           Permanent Removal of Snubber Supports SPDBA1 03 H2000 and SPDBA1 07-H2000 310917
DESIGN CHANGE SYSTEM / CLASS PACKAGE DESCRIPTION NUMBER 97-9100D, F and G 024A III Replaced Fuel Oil Day Tank level transmitters 179458 145AI Permanent Removal of Snubber Supports SPDBA1 03 H2000 and SPDBA1 07-H2000 310917
* 147           Welded repairs to nozzle base metal damage on replacement Feedwater Heaters 94-3023B and C                   149A III         Replacement and Repair of RHR Motor Oil Coolers 179459                           149C I           Permanent Removal of Snubber Support SPDCA1 17 H14 352940                           151A II         Relocation of Instrument Rack 1C057 318280                           153A II         Replace SBLC Pump Discharge Flange and Re-rate SBLC Pump and Discharge Piping, 224005                         161B III         Replace RWCU Pump Proximity Probes with Pipe Plugs.
* 147 Welded repairs to nozzle base metal damage on replacement Feedwater Heaters 94-3023B and C 149A III Replacement and Repair of RHR Motor Oil Coolers 179459 149C I Permanent Removal of Snubber Support SPDCA1 17 H14 352940 151A II Relocation of Instrument Rack 1 C057 318280 153A II Replace SBLC Pump Discharge Flange and Re-rate SBLC Pump and Discharge Piping, 224005 161B III Replace RWCU Pump Proximity Probes with Pipe Plugs.
316329, 316330,                 162AI           Modified inboard MSIVs, HV141F022A, B, C, and D to 316331,316332                                     improve seating characteristics.
316329, 316330, 162AI Modified inboard MSIVs, HV141F022A, B, C, and D to 316331,316332 improve seating characteristics.
179460                           162A II           Permanent Removal of Snubber Supports SPDCB112 H2003 and SPDCB1 12-H2014 179459                           164A I           Permanent Removal of Snubber Support SPDCA120 H2006 179459                           164A II           Permanent Removal of Snubber Support SPDCB112 H2094 179459                         164D II           Permanent removal of snubber support SPDCB106 391402                                           H2002 and Replaced piping SPDCB106-6, 391467                                           SPDCB106-8, and SPDCB121-4, do to socket weld UT Exam failures.
179460 162A II Permanent Removal of Snubber Supports SPDCB112 H2003 and SPDCB1 12-H2014 179459 164A I Permanent Removal of Snubber Support SPDCA120 H2006 179459 164A II Permanent Removal of Snubber Support SPDCB112 H2094 179459 164D II Permanent removal of snubber support SPDCB106 391402 H2002 and Replaced piping SPDCB106-6, 391467 SPDCB106-8, and SPDCB121-4, do to socket weld UT Exam failures.


316333,316334,                 183A I           Modified outboard MSIVs, HV1 41 F028A, B, C, and D 316335,316336                                  to improve seating characteristics.
316333,316334, 316335,316336 183A I Modified outboard MSIVs, HV1 41 F028A, B, C, and D to improve seating characteristics.
* National Board Inspection Code repair of an ASME Section VIII vessel in a non-nuclear system.
* National Board Inspection Code repair of an ASME Section VIII vessel in a non-nuclear system.


024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603
: 1. Owner                        PPL Susquehanna, LLC                                   Date                          5-JUNE-2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet              1          of Address
: 3. Work Performed by Address PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet Unit 5-JUNE-2002 1
: 2. Plant              Susquehanna Steam Electric Station                              Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                       SEE PAGE 4 AND 5 Address                                                          Repair OrganizatK)n P.O. No., Job No.. etc.
of ONE SEE PAGE 4 AND 5 Repair OrganizatK)n P.O. No., Job No.. etc.
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                             None Name 769 Salem Blvd, Berwick, PA 18603                                    Authorization No.                             N/A Address Expiration Date                               N/A
Type Code Symbol Stamp None Authorization No.
: 4. Identification of System                       DIESEL GENERATOR and AUXILIARY SYSTEM                                         024A-III
N/A Expiration Date
: 5. (a) Applicable Construction Code           SEE PAGE 4 & 5     19         Edition,                         Addenda,                            Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
: 4. Identification of System DIESEL GENERATOR and AUXILIARY SYSTEM
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,             Code Board               Other             Year           Replaced, or         Stamped Name of                  Name of          Manufacturer No.           Identification         Built         Replacement           (Yes or Component              Manufacturer          Serial No.
: 5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
No)
: Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
(1) SMALL PIPE                 BECHTEL                 N/A             N/A           SPHBC94-1               1982           REPLACED               YES ASSEMBLY (2) SMALL PIPE                     PPL                 N/A             N/A           SPHBC94-1               2000       REPLACEMENT                 NO ASSEMBLY (3) 1 PLUG VALVE               TUFLINE             89267L-3           N/A             034072B             1979           REPLACED                 YES XOMOX (4) 1" PLUG VALVE               TUFLINE               89267L-5           N/A             034073B             1979           REPLACED                 YES XOMOX (5) 1" BALLVALVE                   BNL             A981004-1-2         N/A             034073B             1999       REPLACEMENT                 YES INDUSTRIES (6) SMALL PIPE                 BECHTEL                 N/A             N/A             SPHBC94-             1982           REPLACED                 NO SUPPORT                                                                             H2000
: 6. Identification of Components Repaired or Replaced and Replacement Components
: 7. Description of Work                                                    SEE PAGE 4 AND 5
: Addenda, Code Case
: 8. Tests Conducted:      Hydrostatic    F        Pne =umatic  FE      Nominal Operating Pressure              I-D Other    E        Pressure          N/A      psi    Test Temp.              N/A          °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 7. Description of Work SEE PAGE 4 AND 5
(12/82)                         This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 8. Tests Conducted:
Hydrostatic F Pne Other E Pressure
=umatic FE N/A Nominal Operating Pressure psi Test Temp.
N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant N/A 024A-III ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
(1) SMALL PIPE BECHTEL N/A N/A SPHBC94-1 1982 REPLACED YES ASSEMBLY (2)
SMALL PIPE PPL N/A N/A SPHBC94-1 2000 REPLACEMENT NO ASSEMBLY (3) 1 PLUG VALVE TUFLINE 89267L-3 N/A 034072B 1979 REPLACED YES XOMOX (4) 1" PLUG VALVE TUFLINE 89267L-5 N/A 034073B 1979 REPLACED YES XOMOX (5) 1" BALLVALVE BNL A981004-1-2 N/A 034073B 1999 REPLACEMENT YES INDUSTRIES (6) SMALL PIPE BECHTEL N/A N/A SPHBC94-1982 REPLACED NO SUPPORT H2000 I-D
°F (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks       CODE DATA REPORT(S) ATTACHED Applicable Manufacturer's Data Renors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               REPLACEMENT               conforms to the rules of the ASME Code, Section Xl.                                                                       repair or replacement Type Code Symbol Stamp                                                                     N/A Certificate of Authorization No.                     N/A                     Expiration                                   N/A Signed                   .                                                        Date                   ,<      2/-           20 e Owner(& Owner's     ee, Title   Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by                 FACTORY MUTUAL INSURANCE CO.
: 9. Remarks CODE DATA REPORT(S) ATTACHED Applicable Manufacturer's Data Renors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.
JOHNSTON, RHODE ISLAND                                                                                                                         of have inspected the components described in this Owner's Report during the period                 /,-/10 9-                         to               !T- A- 0/             -      and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed Date 2/-
20 e Owner(& Owner's ee, Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period  
/10
/,-
9-to  
!T-A-0/
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
2??'Commissions A113 7 980 1L~4~i, Inspector's *Vnature A. N. 1; 9?- AU         P4 ~Z-       C&#xfd;0J National Board, State, Province, and Endorsements Date     ,J.iN     ZL I             2002 r'h
1L~4~i, 2??'Commissions A113 7 980 A. N. 1; 9?- AU P4 ~Z-C&#xfd;0J Inspector's *Vnature National Board, State, Province, and Endorsements Date  
,J.iN ZL I 2002 r'h


024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Date Sheet Add Unit SEE PAGE 4 AND 5
: 1. Owner                          PPL Susquehanna, LLC                                   Date                        5-JUNE-2002 Name 769 Salem Blvd, Berwick, PA 18603                                     Sheet            2          of                      2 Address                                     Add
: 3. Work Performed by 769 Salem Address PPL Sus Blvd, Berwic Address
: 2. Plant                Susquehanna Steam Electric Station                               Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                         SEE PAGE 4 AND 5 Address                                     Adcre                 Repair OrganIzation P.O. No., Job No., etc
: 4. Indentification of System Adcre Repair OrganIzation P.O. No., Job No., etc squehanna, LLC Type Code Symbol Stamp None ck, PA 18603 Authorization No.
: 3. Work Performed by                  PPL Sussquehanna, LLC                             Type Code Symbol Stamp                             None 769 Salem Blvd, Berwicck, PA 18603                                     Authorization No.                               N/A Address Expiration Date                               N/A
N/A Expiration Date N/A DIESEL GENERATOR and AUXILIARY SYSTEM 024A-III
: 4. Indentification of System                      DIESEL GENERATOR and AUXILIARY SYSTEM                                           024A-III
: 5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
: 5. (a) Applicable Construction Code         SEE PAGE 4 & 5       19           Edition,                         Addenda,                          Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
: Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,           Code Name of                 Name of         Manufacturer         Board               Other             Year           Replaced, or         Stamped Component             Manufacturer         Serial No.         No.             Identification         Built         Replacement           (Yes No) or (7)   SMALL PIPE                 BECHTEL                 N/A             N/A             SPHBC94-               1982           REPLACED               NO SUPPORT                                                                               H2001 (8)   SMALL PIPE                 BECHTEL                 N/A             N/A             SPHBC96-1               1982           REPLACED               YES ASSEMBLY (9)   SMALL PIPE                   PPL                 N/A             N/A             SPHBC96-1             2000         REPLACEMENT               NO ASSEMBLY (10)   1" PLUG VALVE           TUFLINE             89267L-1           N/A               034072D             1979           REPLACED               YES XOMOX (11)   1"PLUG VALVE             TUFLINE             89267L-7           N/A               034073D             1979           REPLACED               YES XOMOX (12)   1" BALL VALVE               BNL           A981004-1-4           N/A               034073D             1999         REPLACEMENT               YES INDUSTRIES (13)   SMALL PIPE               BECHTEL               N/A             N/A             SPHBC96-             1982           REPLACED               NO SUPPORT                                                                               H2000 (14)   SMALL PIPE               BECHTEL               N/A             N/A             SPHBC96-             1982           REPLACED               NO SUPPORT                                                                               H2001 (15)   LEVEL                   MORRISON               SA-613           N/A               SA-613             1985           REPLACED               YES TRANSMITTER               KNUDSEN PIPE ASSEMBLY
: 6. Identification of Components Repaired or Replaced and Replacement Components
: Addenda,
: 1. Owner
: 2. Plant 5-JUNE-2002 2
of 2
ONE Code Case ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
(7)
SMALL PIPE BECHTEL N/A N/A SPHBC94-1982 REPLACED NO SUPPORT H2001 (8)
SMALL PIPE BECHTEL N/A N/A SPHBC96-1 1982 REPLACED YES ASSEMBLY (9)
SMALL PIPE PPL N/A N/A SPHBC96-1 2000 REPLACEMENT NO ASSEMBLY (10) 1" PLUG VALVE TUFLINE 89267L-1 N/A 034072D 1979 REPLACED YES XOMOX (11) 1"PLUG VALVE TUFLINE 89267L-7 N/A 034073D 1979 REPLACED YES XOMOX (12) 1" BALL VALVE BNL A981004-1-4 N/A 034073D 1999 REPLACEMENT YES INDUSTRIES (13)
SMALL PIPE BECHTEL N/A N/A SPHBC96-1982 REPLACED NO SUPPORT H2000 (14)
SMALL PIPE BECHTEL N/A N/A SPHBC96-1982 REPLACED NO SUPPORT H2001 (15)
LEVEL MORRISON SA-613 N/A SA-613 1985 REPLACED YES TRANSMITTER KNUDSEN PIPE ASSEMBLY


024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                         PPL Susquehanna, LLC                                   Date                        5-JUNE-2002 Name 769 Salem BIvd, Berwick, PA 18603                                     Sheet            3            of                      3 Address                                     Add
: 1. Owner
: 2. Plant              Susquehanna Steam Electric Station                               Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                         SEE PAGE 4 AND 5 Address                                      Addre                 Repair Organization P.O. No., Job No., etc.
: 2. Plant PPL Susquehanna, LLC Name 769 Salem BIvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 3. Work Performed by                  PPL Sus squehanna, LLC                           Type Code Symbol Stamp                             None 769 Salem Blvd, Berwic:k, PA 18603                                     Authorization No.                             N/A Address Expiration Date                               N/A
: 3. Work Performed by PPL Sus 769 Salem Blvd, Berwic Address
: 4. Indentification of System                      DIESEL GENERATOR and AUXILIARY SYSTEM                                           024A-III
: 4. Indentification of System Date Sheet Add Unit 5-JUNE-2002 3
: 5. (a) Applicable Construction Code         SEE PAGE 4 & 5       19         Edition,                         Addenda,                            Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
of 3
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,             Code Board               Other               Year         Replaced, or         Stamped Name of                Name of          Manufacturer Component             Manufacturer         Serial No.         No.           Identification         Built         Replacement           (Yes or (16)   BLIND FLANGE               PPL                 N/A             N/A               SA-613             2000         REPLACEMENT               NO (17)   SMALL PIPE                 PPL                 N/A             N/A         SPHBC3304-14             2000         REPLACEMENT               NO ASSEMBLY (18)   1" BALL VALVE               BNL             A990801-2-2           N/A             034829E             2000         REPLACEMENT               YES INDUSTRIES (19)   PIPE PLUG               APPLIED             NC-4164-05         2742             OT-528E               1984           REPLACED               NO NOZZLE H             ENGINEERING
ONE SEE PAGE 4 AND 5 Addre Repair Organization P.O. No., Job No., etc.
squehanna, LLC Type Code Symbol Stamp None
:k, PA 18603 Authorization No.
N/A Expiration Date N/A DIESEL GENERATOR and AUXILIARY SYSTEM 024A-III
: 5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
: Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components
: Addenda, Code Case ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or (16) BLIND FLANGE PPL N/A N/A SA-613 2000 REPLACEMENT NO (17)
SMALL PIPE PPL N/A N/A SPHBC3304-14 2000 REPLACEMENT NO ASSEMBLY (18) 1 " BALL VALVE BNL A990801-2-2 N/A 034829E 2000 REPLACEMENT YES INDUSTRIES (19)
PIPE PLUG APPLIED NC-4164-05 2742 OT-528E 1984 REPLACED NO NOZZLE H ENGINEERING


024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner                          PPL Susquehanna, LLC                                   Date                          5-JUNE-2002 Name 769 Salem Blvd, Berwick, PA 18603                                     Sheet             4           of                     4 Address                                    Add
024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet 5-JUNE-2002 4
: 2. Plant              Susquehanna Steam Electric Station                               Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                       SEE PAGE 4 AND 5 Address                                    Addre                  Repair Organization P.O. No, Job No., etc
of Add Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603
: 3. Work Performed by                  PPL Susquehanna, LLC                              Type Code Symbol Stamp                           None 769 Salem Blvd, Berwick, PA 18603                                     Authorization No.                            N/A Address Expiration Date                              N/A
: 3. Work Performed by Unit Addre Address PPL Susquehanna, LLC ONE SEE PAGE 4 AND 5 Repair Organization P.O. No, Job No., etc Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address
: 4. Indentification of System                     DIESEL GENERATOR and AUXILIARY SYSTEM                                           024A-III
: 4. Indentification of System Authorization No.
: 5. (a) Applicable Construction Code         SEE PAGE 4 & 5       19         Edition,                         Addenda,                          Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
Expiration Date DIESEL GENERATOR and AUXILIARY SYSTEM
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,           Code Manufacturer         Board               Other             Year           Replaced, or       Stamped Name of                Name of No.           Identification         Built         Replacement         (Yes or Component            Manufacturer          Serial No.
: 5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
No)
: Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
ITEM     WORK ORDER I JOB NUMBER                         CONSTRUCTION CODE                                   DESCRIPTION OF WORK 1 -2     PCWO 99998 / DCP 97-9100D                           ASME SECTION III                       REPLACEMENT OF BRAVO DIESEL DAY CRF G99-023-010                     1971 EDITION, WINTER 72 ADD.                     TANK LEVEL TRANSMITTER PIPING 3 -4     PCWO 99998 / DCP 97-9100D                           ASME SECTION III                           BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010                     1977 EDITION, SUMMER 78 ADD.                       TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE 5       PCWO 99998 / DCP 97-9100D                           ASME SECTION III                           BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010                       1974 EDITION, NO ADDENDA.                           TRANSMITTER REPLACEMENT ISOLATION VALVE 6 -7     PCWO 99998 / DCP 97-9100D                           ASME SECTION III                           BRAVO DIESEL DAY TANK LEVEL CRF G99-023-015                     1971 EDITION, WINTER 72 ADD.                         TRANSMITTER DELETED PIPE SUPPORTS 8-9       PCWO 100221 / DCP 97-9100F                         ASME SECTION III                       REPLACEMENT OF DELTA DIESEL DAY CRF G99-024-012                     1971 EDITION, WINTER 72 ADD.                     TANK LEVEL TRANSMITTER PIPING 10- 11     PCWO 100221 / DCP 97-9100F                         ASME SECTION III                           DELTA DIESEL DAY TANK LEVEL CRF G99-024-012                     1977 EDITION, SUMMER 78 ADD.                       TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
ITEM WORK ORDER I JOB NUMBER CONSTRUCTION CODE DESCRIPTION OF WORK 1 -2 PCWO 99998 / DCP 97-9100D ASME SECTION III REPLACEMENT OF BRAVO DIESEL DAY CRF G99-023-010 1971 EDITION, WINTER 72 ADD.
TANK LEVEL TRANSMITTER PIPING 3 -4 PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010 1977 EDITION, SUMMER 78 ADD.
TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE 5
PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010 1974 EDITION, NO ADDENDA.
TRANSMITTER REPLACEMENT ISOLATION VALVE 6 -7 PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-015 1971 EDITION, WINTER 72 ADD.
TRANSMITTER DELETED PIPE SUPPORTS 8-9 PCWO 100221 / DCP 97-9100F ASME SECTION III REPLACEMENT OF DELTA DIESEL DAY CRF G99-024-012 1971 EDITION, WINTER 72 ADD.
TANK LEVEL TRANSMITTER PIPING 10- 11 PCWO 100221 / DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-012 1977 EDITION, SUMMER 78 ADD.
TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE 1 Owner
: 2. Plant 4
N/A N/A 024A-III
: Addenda, Code Case


024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner                        PPL Susquehanna, LLC                                   Date                        5-JUNE-2002 Name 769 Salem Blvd, Berwick, PA 18603                                     Sheet           5            of                      5 Address                                      Add ONE
024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet Add Susquehanna Steam Electric Station Name Unit 5-JUNE-2002 5
: 2. Plant              Susquehanna Steam Electric Station                               Unit Name 769 Salem Blvd, Berwick, PA 18603                                       SEE PAGE 4 AND 5 Repair Organization P.O. No., Job No.. etc.
of 5
Addre PP      ussare PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None
ONE 769 Salem Blvd, Berwick, PA 18603
: 3. Work Performed by 769 Salem Blvd, Berwick, PA 18603                                   Authorization No.                             N/A Address Expiration Date                               N/A rltFS'FI (*FNFRATOR and AUXILIARY SYSSTEM                                      024A-1II
: 3. Work Performed by Addre PP sare us PPL Susquehanna, LLC SEE PAGE 4 AND 5 Repair Organization P.O. No., Job No.. etc.
: 4. Indentification of System DIESEL GENERATOR and AUXILIARY SY 19        Edition,                        Addenda,                            Code Case
Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address
: 5. (a) Applicable Construction Code         SEE PAGE 4 & 5             __
: 4. Indentification of System Authorization No.
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
Expiration Date rltFS'FI (*FNFRATOR and AUXILIARY SYS N/A N/A STEM 024A-1II
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Other             Year           Replaced, or         Stamped Name of            Manufacturer      Board Name of Component             Manufacturer           Serial No.         No.           Identification         Built         Replacement             No) or (Yes 12       PCWO 100221 / DCP 97-9100F                         ASME SECTION III                         DELTA DIESEL DAY TANK LEVEL CRF G99-024-012                       1974 EDITION, NO ADDENDA.                         TRANSMITTER REPLACEMENT ISOLATION VALVE 13-14       PCWO 100221 1 DCP 97-9100F                         ASME SECTION III                         DELTA DIESEL DAY TANK LEVEL CRF G99-024-017                     1971 EDITION, WINTER 72 ADD.                         TRANSMITTER DELETED PIPE SUPPORTS 15- 16     PCWO 100222 / DCP 97-9100G                         ASME SECTION III                           ECHO DIESEL DAY TANK LEVEL CRF G99-023-013                     1980 EDITION, SUMMER 81 ADD                     TRANSMITTER REPLACEMERNT OF CODE CASE N-316.                             EXISTING WITH BLIND FLANGE 17       PCWO 100222 / DCP 97-9100G                         ASME SECTION III                       ECHO DIESEL DAY TANK NEW LEVEL CRF G99-023-013                     1971 EDITION, WINTER 72 ADD                     TRANSMITTER SMALL BORE PIPE INSTALLATION 18       PCWO 100222 / DCP 97-910OG                         ASME SECTION III                           ECHO DIESEL DAY TANK LEVEL CRF G99-023-013                       1974 EDITION, NO ADDENDA                   TRANSMITTER NEW ISOLATION VALVE 19       PCWO 100222/ DCP 97-91 OOG                         ASME SECTION III                           ECHO DIESEL DAY TANK LEVEL CRF G99-023-013                     1980 EDITION, SUMMER 81 ADD                   TRANSMITTER RELOCATION TO TANK SPARE NOZZLE LOCATION H.
: 5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
: Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: Addenda, Code Case
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No) 12 PCWO 100221 / DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-012 1974 EDITION, NO ADDENDA.
TRANSMITTER REPLACEMENT ISOLATION VALVE 13-14 PCWO 100221 1 DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-017 1971 EDITION, WINTER 72 ADD.
TRANSMITTER DELETED PIPE SUPPORTS 15-16 PCWO 100222 / DCP 97-9100G ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1980 EDITION, SUMMER 81 ADD TRANSMITTER REPLACEMERNT OF CODE CASE N-316.
EXISTING WITH BLIND FLANGE 17 PCWO 100222 / DCP 97-9100G ASME SECTION III ECHO DIESEL DAY TANK NEW LEVEL CRF G99-023-013 1971 EDITION, WINTER 72 ADD TRANSMITTER SMALL BORE PIPE INSTALLATION 18 PCWO 100222 / DCP 97-910OG ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1974 EDITION, NO ADDENDA TRANSMITTER NEW ISOLATION VALVE 19 PCWO 100222/ DCP 97-91 OOG ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1980 EDITION, SUMMER 81 ADD TRANSMITTER RELOCATION TO TANK SPARE NOZZLE LOCATION H.
1 Owner
: 2. Plant DIESEL GENERATOR and AUXILIARY SY


For Information Only PUMPS OR VALVES*
For Information Only FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR by the   Provisions     of the ASME     Code,     Section       Ill. Division 1 Pg. l of_           2 As Required VERNON,      CT, 06066 CIcertified by         NL INDUSTRIES,             INC.,       30 INDUkTRIAL PARK ROAD,
As Required by the Provisions of the ASME Code, Section Ill. Division 1 2
: 1. ManufactureSd                                                        (rwre ". edd       o N Cetflslft
Pg. l of_
                                                                                                          .*I.               . 4016w)
: 1. ManufactureSd CI certified by NL INDUSTRIES, INC.,
PEN*(SYLVANIA             POWER & LIGHT CO,                 TwO NORTH NINTH ST,ALLENTOWN,PA 18101
30 INDUkTRIAL PARK ROAD,
: 2. Manufactured for                                                                         of Prchaseed imam* w4odadd.e.
: VERNON, CT, 06066 (rwre ". edd  
SUSQUEHANNA,             5 MI NE OF BERWICK,                   PA,       18603
.*I.
: 3. Locationl of inatbllatgofl (nrwne end addreIai/
o N Cetflslft
HBV-A2-06-00 58                         0 VALVE              Drawig                              Rev.                        CRN
. 4016w)
: 4. Model No., Series No., or T"ype
PEN*(SYLVANIA POWER & LIGHT CO, TwO NORTH NINTH ST,ALLENTOWN,PA 18101
                                                                                  /                -                          3      /
: 2. Manufactured for imam* w4od add.e.
Code. Seciion IN, Division 1:           -1974
of Prchaseed SUSQUEHANNA, 5 MI NE OF BERWICK, PA, 18603
: 5. AS&                                                  ledoDlon)             laddenda d.tea                   Icl*a/             (Code Came no.1             O 3/4"                             .          3/4 VALVE                                                                    O utlet                    lip)
: 3.
: 6. Pump or vhs*v                                 Nominal inlet in--
Locationl of inatbllatgofl (nrwne end addreIai/
SA- 105                       SA-479 Ty316                         SA-193 GrB7/SA-194 Gr2H SA-105                                                                                          Bolting "7.Material:   Body       -onnt                             _                        Disk 1c)                                                            f*)
VALVE HBV-A2-06-00 58 0
(a)                             1b)                                                                                           Disk Nt'l                           Do*y Conl.                                                                                          serial                          Serial Board Holder's                                                         No.                             No.                           No.     /
: 4. Model No., Series No., or T"ype Drawig Rev.
Serial No.         /               No.
CRN
: 5. AS&
Code. Seciion IN, Division 1:  
-1974  
/
3
/
ledoDlon) laddenda d.tea Icl*a/
(Code Came no.1 VALVE 3/4" 3/4
: 6. Pump or vhs*v Nominal inlet in--
O utlet lip)
SA-105 SA-105 SA-479 Ty316 SA-193 GrB7/SA-194 Gr2H "7.
Material:
Body  
-onnt Disk Bolting (a) 1b)
Conl.
Nt'l Holder's Board Serial No.  
/
No.
A981004-I- (1THRU4) 1c)
Do*y No.
N62 serial No.
O f*)
Disk Serial No.  
/
L95/
L95/
N62 A981004-I- (1THRU4)
-S*ppjsslal inOflt,,*don in fo oiu e6lM. l O
              - S*ppjsslal inOflt,,*donin fo       oiu     e6lM.l an a.mdrowt, gs may ba, used pr'ovded1) @!z Is N18 O                                                        0               21 hf Mmqinnheams I t1rough 4 1K. ill on twh Del. Aeport is ircudad on eoch       ~hi, 131 eat   doth is rwjvnbed e"d the nmamrbr of ,eOft is rwrded 01 the too f Unla tfom.
an a.m drowt, gs may ba, used pr'ovded1) @! z Is N18 0
E000371 may be 0 ta-       ism dw COnswDept.. AhW.       22 Law OuSDr*.       ba2300, FoaId, NJ 07007-2300.
1K. ill 21 hf Mmqinn heams I t1rough 4 on twh Del. Aeport is ircudad on eoch  
(121")                      Thi fog..
~hi, 131 eat doth is rwjvnbed e"d the nmamrbr of,eOft is rwrded 01 the too f Unla tfom.
(121")
Thi fog..
E000371 may be 0 ta-ism dw COnsw Dept.. AhW. 22 Law OuSDr*. ba2300, FoaId, NJ 07007-2300.


,or Information Only FORM NPV- 1(B ack- P g.2of               .f.2-   Z- )
,or Information Only FORM NPV-1 (B ack -
I ~       Certificats Holder's Sedial No.
P g.2of 2-Z- )  
.f.
I ~
Certificats Holder's Sedial No.
ANSI 600#
ANSI 600#
psi                           IF or vshve presaure las1                                   It)
S. Design conditlons psi IF or vshve presaure las1 It) 1presstuereltw~
S. Design conditlons            1presstuereltw~
: 9. Cold workig pressure 10 palatIOOF
: 9. Cold workig pressure             10                       palatIOOF                                         /
/
2225                                                                     1630
2225 1630
: 10. H*vdroetstic teat                           psi. Disk dMiereniai test pressure
: 10. H*vdroetstic teat psi.
Disk dMiereniai test pressure
: 11. Remarrks:
: 11. Remarrks:
CEwRTIFCATION OF DESIGN J.G.         SHELLENBERGER                                   PA                           19551-E P.E. State                       Pftg. no.
CEwRTIFCATION OF DESIGN J.G.
Design Specification certified by PA. Stat.                       Reg. no.
SHELLENBERGER PA 19551-E Design Specification certified by P.E. State Pftg. no.
Desigy Report certified by CERTIFICATE OF COMPLIANCE constuction We cegrty het the statements made in his report wre correct and that this pump or valve conforms to the rnles for Divlsion      1.        )-2882                                                      11/10/01 of the ASME Code, Section IN, Explree h4Certificate of Authorlzatlon No INC.                Signed    _
Desigy Report certified by PA. Stat.
Dite    06/17/99        -N          BNL INDUSTRIES, (N Cardfrate  ai.e.)
Reg. no.
CERTIFICATS OF INSPECT)ON BOaOd Of 00lggV                                            d T* aner
: 1. the unidetsigned. hokling a vaid commnssirn Issued by the National            and employed by Province  of        CONNECTI            CUT the State or                                                                                                                                    on of          BOSTON,      M4AS S                                      have Inspected the pump. or valve, descrkmd in this Date Report hea co*
06/17/9                        .nd    state that to the best of my knowledge and belief, the Certificate Holder Section 111,Diviasion 1.
atructed this pump, or valve, In eccotdamn1 with the ASME Code.
miesi eny, warranty, expressed or Implied. coricrnilg the Sy signing this certificate. neither the inspectot nor his employer Data  Report.      Furthermore. neither the Inspector not his employer shall be liable in ars mannw tfr component described In this from or cornected with ths inspection.
                "ary  perseeal inp.Wy or property damage or a loss of any kind arising
* CommisslonseJ r4        /3      9cM4      4    l        c7 fq-        d Data                Signed LAuth*Oz*        WO M1        ~fol.                1n1coe Be. (irnS. endorsernerval and state or prey, end n9J
: 11) For manually operated valV*s Only.
: 11) For manually operated valV*s Only.
CERTIFICATE OF COMPLIANCE We cegrty het the statements made in his report wre correct and that this pump or valve conforms to the rnles for constuction of the ASME Code, Section IN, Divlsion 1.
)-2882 11/10/01 h4 Certificate of Authorlzatlon No Explree Dite 06/17/99
-N BNL INDUSTRIES, INC.
Signed (N Cardfrate ai.e.)
CERTIFICATS OF INSPECT)ON
: 1. the unidetsigned. hokling a vaid commnssirn Issued by the National BOaOd Of 00lggV aner T*
d the State or Province of CONNECTI CUT and employed by of
: BOSTON, M4AS S have Inspected the pump. or valve, descrkmd in this Date Report on 06/17/9
.nd state that to the best of my knowledge and belief, the Certificate Holder hea co*
atructed this pump, or valve, In eccotdamn1 with the ASME Code. Section 111, Diviasion 1.
Sy signing this certificate. neither the inspectot nor his employer miesi eny, warranty, expressed or Implied. coricrnilg the component described In this Data Report. Furthermore. neither the Inspector not his employer shall be liable in ars mannw tfr "ary perseeal inp.Wy or property damage or a loss of any kind arising from or cornected with ths inspection.
Data Signed Commisslons r4
/3 9cM4 l
4 eJ c7 fq-d LAuth*Oz*
WO M1 1n1coe
~fol.
Be. (irnS. endorsernerval and state or prey, end n9J


rTnf ormation Only PUMPS OR VALVES*
rTnf ormation Only FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR As Required by the Provisions of the ASME Cods, Section 111,Division I p.Io PARK ROAD, VERNON,                    CT, 06066 BNL INDUSTRIES,              INC.,    30    INDUSTRIAL
As Required by the Provisions of the ASME Cods, Section 111, Division I p.Io
: 1. Manufacured an otfied           'by iname end aM... of N Cart~fica       Hoidmi)
: 1. Manufacured an otfied  
PENNSYLVANIA POWER & LIGHT CO,                               TWO NORTH NINTH ST,ALLENTOWN,PA 18101 Z. MaWVCIUTId                                             amAaiddr rnae             of Puechaaar 3.Loatonof"WstonSUSQUEHANNA,                         5 MI NE OF BERWICK, PA, 18603 Inam.rand .ddresal 9
'by BNL INDUSTRIES, INC., 30 INDUSTRIAL PARK ROAD, VERNON, CT, 06066 iname end aM... of N Cart~fica Hoidmi)
HBV-A2-40-00S                       A VALVE Drowing                            PAY.              -          CR14 A4.Model No-, Serie No., or Type
PENNSYLVANIA POWER & LIGHT CO, TWO NORTH NINTH ST,ALLENTOWN,PA 18101 Z. MaWVCIUTId rnae amA aiddr of Puechaaar 3.Loatonof"WstonSUSQUEHANNA, 5 MI NE OF BERWICK, PA, 18603 Inam.r and.ddresal VALVE HBV-A2-40-00S 9
A A4. Model No-, Serie No., or Type Drowing PAY.
CR14
: 5. ASIAE Code. Section III, Division 1:
: 5. ASIAE Code. Section III, Division 1:
1974_______3 (Code Cowar-.
1974_______3 VAVEidsoanl 1 addends ate 41icisasi (Code Cowa r-.
1            41icisasi addends ate VAVEidsoanl Nominal inlet al~                  .-                  is            1*,
: 6. Pum~p or valve VA Nominal inlet al~
: 6. Pum~p or valve             VA SA-105                       SA-479 Ty3165                         SA-193 GrB7/SA-194 Gx2E SA-1O5                  onnet _________
1*,
S______                            Disk                                aohing
is SA-1O5 SA-105 SA-479 Ty3165 SA-193 GrB7/SA-194 Gx2E
: 7. Maiarial:       Body-as)                               ID]                           cc)                                                            Disk Cart.                             Nat'l                       So"y                                                            Solial Seilal Holder's           /               Board No.                           No.1/
: 7. Maiarial:
Sedal No..                            No.
Body-S______
2                                                        Ml 60 A,9810_4_-         - (1THRU2) oSuppt~ms   r ntm W mlova i~e inm t o     fnlimo., sk that",ear dtaw kg May 'a imaadPmvoda 11) ae IaoCV K 11~.Ili hI c,..udat             h n banamI titr o og4 on sael   cheam.131each  ehat it nunbard and     iwbar thea        of Omar   is reor~ded   at thatoP Of d"e 1100%.
onnet _________
on chis Dole ftaaor is ircluded Drive. Sos 2300, Fajrfiald N.J07007-2300-1121601                         ThW& form, JE000371 Inal be 06016a fromt va Order Dapv,.ASMI, 22 Low
Disk aohing as)
ID]
Cart.
Nat'l Holder's  
/
Board Sedal No..
No.
A,9810_4_-
2 - (1THRU2) cc)
So"y No.
Ml 60 Seilal No.1/
Disk Solial o
Suppt~ms r W ntm mlo va i~e inm t o fn limo., sk that ",e ar dtaw kg M ay 'a imaad Pmvo da
: 11) ae Iao CV K 11~. Ili hI c,..udat h n ba nam I titr o og 4 on chis Dole ftaaor is ircluded on sael cheam.
131 each ehat it nunbard and thea iwbar of Omar is reor~ded at thatoP Of d"e 1100%.
1121601 ThW&
form, JE000371 Inal be 06016a fromt va Order Dapv,.ASMI, 22 Low Drive. Sos 2300, Fajrfiald N.J 07007-2300-


er Ijformation        Only FOaRM NPV-1 (Back - Pg.2of                       2- -)
er Ijformation Only FOaRM NPV-1 (Back - Pg.2of 2- -)
98        _(ITHRU2)
Certifcsta Hokla's Sial No..A 9 8 1004
Certifcsta Hokla's Sial No..A               1004                                                                                                                                         ANSI     600#
_(ITHRU2)
psi                 ra'F             of volvo Presaroe                                       ill
ANSI 600#
: a. Oesign condilionl
: a. Oesign condilionl psi ra'F of volvo Presaroe ill
: 9. Col working pasae                 10                 psl atlOO0F 2225     /                                                           1630       /
: 9. Col working pasae 10 psl atlOO0F 2225  
163 2ps.               Disk afferantial lest prsau-
/
: 10. Hydrostatic test
1630  
/
: 10. Hydrostatic test 2ps.
Disk afferantial lest prsau-163
: 11. Remork3:
: 11. Remork3:
CERTIFICATION OF DESIGN J.G. SHELLENBERGER                                         PA                             19551-E P.1. State                         Reg. no.
CERTIFICATION OF DESIGN J.G. SHELLENBERGER PA 19551-E Design Specification certified by P.1. State Reg. no.
Design Specification certified by P.. State                         PM. no.
Design Repor certified by P.. State PM. no.
Design Repor certified by CERTIRCATE oF COMPUANCE We certift   "   the statamenus made In this report are correct ar*d that this pump or valve conforms to the rubs for ConstnictiOn of the ASME Code. Section 11I.Dvision 1.               N-2882                                                         11/10/01 N Certificate of Authwaortioin No.                                                                   Expires 06/17/99                   BNL INDUSTRIES,                 INC.                                         6td Onto                             ~~~IN Cu~wtifet HPdw                         igw CENWICATIE OF INSPECTION noctSed 1, the undersigned. holting a valid comrngealofl Issued by the National board ofDlarndPereVoe the Siate or Province of         CONNECTICUT                               and employed             OU SBOSTON, MASS                                                     hove Insected the pump. or valve. described in this Dots AePort on 06/17/99                       n   elate that to the beet of my knowledge athd belief, the Certifcte Holder has con atnictod this pump, or valve, I accordance with the ASME Code, Section 10, Div                   n 1.
CERTIRCATE oF COMPUANCE We certift  
conceinng the By aignirn this certificate, neither the inspector not lie employer mikes any warranty, expreased or Implied, in this Data Report. Furthermore.     neilhee the inspector nor   his amployer shall be liabie in env manner few compontfll deacrlbed any personel knpry or properts"     mage ora loss of any kind arising from or connected with this inspection.
" the statamenus made In this report are correct ar*d that this pump or valve conforms to the rubs for ConstnictiOn of the ASME Code. Section 11I. Dvision 1.
Dale                 Siqndz                                 :>    ComIuslona           .        ?,. 4. Ad r-7-. / 4(4 L~uthorlsed Inspectorl                         ihati. lsr. 1Und.endorernaestl andstate or prow. end no.1 I1) Far manually operated     v1Vea only.
N-2882 11/10/01 N Certificate of Authwaortioin No.
Expires 06/17/99 BNL INDUSTRIES, INC.
6td Onto  
~~~IN Cu~wtifet HPdw igw CENWICATIE OF INSPECTION 1, the undersigned. holting a valid comrngealofl Issued by the National board ofDlarndPereVoe noctSed the Siate or Province of CONNECTICUT and employed OU SBOSTON, MASS hove Insected the pump. or valve. described in this Dots AePort on 06/17/99 n
elate that to the beet of my knowledge athd belief, the Certifcte Holder has con atnictod this pump, or valve, I accordance with the ASME Code, Section 10, Div n 1.
By aignirn this certificate, neither the inspector not lie employer mikes any warranty, expreased or Implied, conceinng the compontfll deacrlbed in this Data Report. Furthermore. neilhee the inspector nor his amployer shall be liabie in env manner few any personel knpry or properts" mage ora loss of any kind arising from or connected with this inspection.
Dale Siqndz ComIuslona  
?,. 4. Ad r-7-. /
4 (4 L~uthorlsed Inspectorl ihati. lsr. 1Und. endorernaestl andstate or prow. end no.1 I1) Far manually operated v1Vea only.


n-r FORM NPV-1 CERTIFICATE HOLOERS'DATA REPORT FOR NUCLEAR PUMPS OR VALVES' As Required by the Provisions of the ASME Co",.Section 1II, DivWon 1 P.Io 5liL INDUSTRIES,             INC.,     30   INDUSTRIAL         PARK ROAD,         VERNON,     CT, 06066
FORM NPV-1 CERTIFICATE HOLOERS'DATA REPORT FOR NUCLEAR PUMPS OR VALVES' As Required by the Provisions of the ASME Co",. Section 1II, DivWon 1 P.Io
: 1. Manufacturend Acarti~fidby (namei and addrawmof N CariffieatoHolder?
: 1. Manufacturend Acarti~fidby 5liL INDUSTRIES, INC., 30 INDUSTRIAL PARK ROAD, VERNON, CT, 06066 (namei and addrawm of N Cariffieato Holder?
PENNSYLVANIA         POWER       & LIC;H-T CO,       TWO NORTH NINTH             ST,ALLENTrOWN,PA             18101
PENNSYLVANIA POWER  
: 2. MantrfactUund for
& LIC;H-T CO, TWO NORTH NINTH ST,ALLENTrOWN,PA 18101
                                                                        -mam Sn addrss ofprc1     r SUSQUEHANNA,             5 MI FE OF BERWICK,                 PA,   18603
: 2. MantrfactUund for  
: 3. Location of kwuat~eion VALVE                     HBV-Z 10-           0%Th         A
-mam Sn addrss ofprc1 r
: 4. Model No.. Serins No., of Type                             Drawing                       Pav. ______             CRN_____
SUSQUEHANNA, 5 MI FE OF BERWICK, PA, 18603
: 5. ASME Code. Section 111oj.iuiaon 1;-           1974/..                                           3 geditwnrl             touddndo ""1               11:9111             (Cede Came no.1 Otrdri-!,          .
: 3. Location of kwuat~eion VALVE HBV-Z 10-0%Th A
VA   E                 nik   Inleto.
: 4. Model No.. Serins No., of Type Drawing Pav. ______
: a. Pumnpor aiv                                                                                                  0h.1 SA-10, 5             one       SA-1{5                     SA-479 Ty316,,,4               SA-293GrB7/SA-I94Gz2H /
CRN_____
: 7. Mart&"a:   Body                           ont_______                   -  Disk                         Bow"M
: 5. ASME Code. Section 111 oj.iuiaon 1;-
: 10)                        id)                            (01 18)
1974/..
Carl                                                       body                      bonn~l Holder'$                       Board No.                        me.                          No.                          No.
3 geditwnrl touddndo ""1 11:9111 (Cede Came no.1
: a. Pumnp or aiv VA E
nik Inleto.
Otrdri-!,
0h.1 SA-10, 5 one SA-1{5 SA-479 Ty316,,,4 SA-293GrB7/SA-I94Gz2H /
: 7. Mart&"a:
Body ont_______
Disk Bow"M
: 18)
Carl Holder'$
Serilel No.
Serilel No.
L73                        N218 A.990801       (1)~                                           N56                                                         N218
A.990801 (1)~
    *Suppiwenwtal intoraw4.A In       & lism, smah.ee or dre Igsao rwbe waed p6avld-d 11) *its 1* S% x 11, f2s bkfnlonitlon in heme I through~ 4
Board No.
                                      .9-on "taData pepoet is,           .addea.
: 10) body me.
on~eeach        J) gecohwnwt Is nwyueranie~end tha my.b, of ~mat ie "Cacrded at Ont to of 6"e torm.
N56 id) bonn~l No.
112151)Thitl           leswa(1000371 may Ia. ob~dtrw         t.e crew. Do"_ ASM*. 22 Low Dri.,.. 111" 2300, F.irfaeil. NJ 07007-22M0.
L73 (01 No.
N218 N218
*Suppiwenwtal intoraw4.A In  
.9-
& lism, smah.ee or dre Ig sao rwbe waed p6avld-d 11) *its 1* S% x 11, f2s bkfnlonitlon in heme I through~ 4 on "ta Data pepoet is, on~e each
.addea.
J) gecoh wnwt Is nwyueranie~end tha my.b, o f
~mat ie "Cacrded at Ont to of 6"e torm.
112151)Thitl lesw a(1000371 may Ia. ob~dtrw t.e crew. Do"_ ASM*. 22 Low Dri.,.. 111" 2300, F.irfaeil. NJ 07007-22M0.
n-r


or rfrnrm,-Itinn           Onl';
or rfrnrm,-Itinn Onl';
FORM NPV-1 (Back           -   Pg. 2 of       2   1 A990801 (142)
FORM NPV-1 (Back -
Pg. 2 of 2
1 A990801 (142)
Cartlite-ste Holder's Serial No.
Cartlite-ste Holder's Serial No.
ANSI 600#
ANSI 600#
: 8. Design conditlos                                   PSI                           IF or vale     pressure ciass
: 8. Design conditlos PSI IF or vale pressure ciass
: 9. Cold working pressure               10                 psi at 10001 2225                                                               1630
: 9. Cold working pressure 10 psi at 10001 2225
: 10. Hydrosateic test                           pai. Disk dlflerntial lail DraSKKw is. I&#xb6;atT.ary.a; CERTWWATUO         OF O~ENM D.M. GROVES                                         PA                             24926-E Designi Spectlration cartified     by                                           P.1E.State                       Flag. no.
: 10. Hydrosateic test pai. Disk dlflerntial 1630 lail DraSKKw I&#xb6;atT.ary.a; CERTWWATUO OF O~ENM D.M. GROVES PA 24926-E Designi Spectlration cartified by P.1E. State Flag. no.
Oseegn Report certified     by                                                   P.E.State                       Reg. no.
Oseegn Report certified by P.
CENT111ICATE OF CO&OLAMI(M We ceratiy   "ia the saoitteinerf made In this faplor   are correct a" that this pumnp or vaive conloirri, 10 th. ue for consiruetion ofthe ASh Code,     SectionIIIOM~vloE'1.               N-2882                                                     11/10/01 N Cmnjifitat   at Authodriationi No                                                               Expires Signmed          C7--          &#xfd;      &#xfd; Daa06/01/00           Nr-BNL             INDUSTRIES,         ]:NC._
E. State Reg. no.
INlQw#a~dstv Haldenl                                   60orifed QWas00Entath CEOlRICATE Of 94SPICTION I. the undersigned, holding a valid commission lssued by ihs National Board at 501Wf arid N and emloe by            OMR1 5i-V9 "q1t~
CENT111ICATE OF CO&OLAMI(M We ceratiy "ia the saoitteinerf made In this faplor are correct a" that this pumnp or vaive conloirri, 10 th. ue for consiruetion ofthe ASh Code, Section IIIOM~vloE'1.
O&#xb6;-5       ~n the Stae" or Province of           CONNECTICUr of BOSTON, M4ASS                                             haev inspescted the pump. or valve, described in this Data Report on 06/01/00                       adstate that to the beat of my knrowledge arnd belief. the Ceniart.fe               Holder has can aurucue   this pumnp, or valve, Inaccordancea with the ASME Code. Section Mll.Division 1.
N-2882 11/10/01 N Cmnjifitat at Authodriationi No Expires Daa06/01/00 Nr-BNL INDUSTRIES,  
Byalgnkig 0110 Certificate. nartherf the hiaSpect nar NO. employer makes any warranty, *Kpremeed or Imnplied. concerning the component deecribed In this Dais Report. Nnhannamioe. neither the Inspector no' hMsemployer shall be liable In any manner for any personal k*Nay at propm t Ammae awoa loam of any kind arising from or connected with this inspection.
]:NC._
Saeigned             -            l-       Coenmieslons       N A             q&#xfd;c                 jC,4             i lA-.Voii.Ad   actorl o                              14nl.likeL . Ond. enderemen-lel and stale or psray. and nel Ill For mar&Aa&sect;V aperate valves only.
INl Qw#a~dstv Haldenl Signmed C7--
&#xfd;
&#xfd; 60orifed QWas00Entath CEOlRICATE Of 94SPICTION I. the undersigned, holding a valid commission lssued by ihs National Board at 501Wf arid N 5i-V9 O&#xb6;-5  
~
the Stae" or Province of CONNECTICUr and emloe by OMR1 "q1t~
n of
: BOSTON, M4ASS haev inspescted the pump. or valve, described in this Data Report on 06/01/00 adstate that to the beat of my knrowledge arnd belief. the Ceniart.fe Holder has can aurucue this pumnp, or valve, In accordancea with the ASME Code. Section Mll. Division 1.
By algnkig 0110 Certificate. nartherf the hiaSpect nar NO. employer makes any warranty, *Kpremeed or Imnplied. concerning the component deecribed In this Dais Report. Nnhannamioe.
neither the Inspector no' hMs employer shall be liable In any manner for any personal k*Nay at propm t Ammae awo a loam of any kind arising from or connected with this inspection.
Saeigned l-Coenmieslons N A q&#xfd;c jC,4 i
lA-.Voii.Ad o actorl 14nl.likeL. Ond. enderemen-lel and stale or psray. and nel Ill For mar&Aa&sect;V aperate valves only.
is.


145AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
145AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                          PPL Susquehanna, LLC                                       Date                            04/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                         Sheet            1            of Address Susquehanna Steam Electric Station                                   Unit                                ONE
: 3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address ECO 179458, PCWO 344339 Repair Organization PO. No., Job No., etc.
: 2. Plant Name ECO 179458, PCWO                I  344339 769 Salem Blvd, Berwick, PA 18603 Address                                                             Repair Organization PO. No., Job No., etc.
Type Code Symbol Stamp None Aiuthorizatinn Nn N/A Expiration Date N/A
: 3. Work Performed by                    PPL Susquehanna, LLC                                Type Code Symbol Stamp         ;b              None Name 769 Salem Blvd, Berwick, PA 18603                                        Aiuthorizatinn Nn                             N/A Address Expiration Date                           N/A Li'Mb
: 4. Identification of System I-I-U W - I I-SYS I EI-M -I 14
: 4. Identification of System                                             I-I-U W - I I- SYS I EI-M -I     14     ULtAZDO I t..,
: 5. (a) Applicable Construction Code ASME Section III 19 71
71    Edition,    Winter 72        Addenda,        N-411            Code Case
: Edition, Winter 72 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 5. (a) Applicable Construction Code           ASME Section III 19 Utilized for Repairs  or Replacements    19    89                  NO ADDENDA (b) Applicable   Edition of Section XI
: 6. Identification of Components Repaired or Replaced and Replacement Components
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                Repaired,            Code Other                Year        Replaced, or        Stamped Name of                    Name of          Manufacturer          Board Identification          Built      Replacement          (Yes or Manufacturer            Serial No.          No.
: Addenda, N-411 NO ADDENDA
Component                                                                                                                                        No)
: 7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
PIPE SUPPORT                  BECHTEL                  N/A              N/A            SPDBA103-               1982        REPLACED              NO H2000 PACIFIC                6668              N/A            SPDBA103-              1979        REPLACED              N/A MECH SNUBBER                SCIENTIFIC                                                      H2000 PIPE SUPPORT                  BECHTEL                  N/A              N/A            SPDBA107-H2000                1982        REPLACED              NO SNUBBER MECH SNSCIENTIFIC              PACIFIC                13970              N/A            SPDBA107-H2000                1981        REPLACED              N/A
: 8. Tests Conducted:
: 7. Description of Work                                           REMOVE SNUBBER / NO REPLACEMENT
Hydrostatic Pneumatic F
: 8. Tests Conducted:         Hydrostatic             Pneumatic       F       Nominal Operating Pressure               D Other   El     Pressure             N/A       psi     Test Temp.           N/A             &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Nominal Operating Pressure D
(12182)                          This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
Other El Pressure N/A psi Test Temp.
N/A  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant Date Sheet 1
of Unit 04/25/2002 ONE Code Case ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
PIPE SUPPORT BECHTEL N/A N/A SPDBA103-1982 REPLACED NO H2000 PACIFIC 6668 N/A SPDBA103-1979 REPLACED N/A MECH SNUBBER SCIENTIFIC H2000 PIPE SUPPORT BECHTEL N/A N/A SPDBA107-1982 REPLACED NO H2000 SNUBBER PACIFIC 13970 N/A SPDBA107-1981 REPLACED N/A MECH SNSCIENTIFIC H2000 (12182)
ULtAZDO I t..,
Li'Mb
;b I


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.
: 9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.
1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 piping per ASME 111,1974 Edition, Summer 1975 Addenda, paragraph NB-3630.                                             CODE CASE N-41 1 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               REPLACEMENT             conforms to the rules of the ASME Code, Section XI.                                                                       repair or replacement Type Code Symbol Stamp                                                                     N/A Certificate of Authorization No.                   N/A                       Expiration                                 N/A Signed                                                                           Date             .        / --            , 20     ..-.
1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 piping per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.
Own     s       T       Seror upv. - Site Modifications Group                                                                         (in>
CODE CASE N-41 1 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by               FACTORY MUTUAL INSURANCE CO.                                       of JOHNSTON, RHODE ISLAND                                                                       have inspected the components described in this Owner's Report during the period                 -31       - (_/                   to to                        -and           --      state that to the best of my knowledge and belief, the Owner has performed examinations and taken codre"'ive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed Date  
/  
, 20 Seror Own s
T upv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period to
-31  
- (_/
to  
-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken codre"'ive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_______________                              Commissions           NFU 7 98             A. N,     ?.3;F s       P,4 z o 4 Inspecto r-ignature                                                   National Board, State, Province, and Endorsements Date.       V -"a 17                 20 2 1q-
Commissions NFU 7 98 A. N,  
?.3;F s P,4 z o 4 Inspecto r-ignature National Board, State, Province, and Endorsements Date.
V -"a 17 20 2 (in>
1q-


FORM R-1 REPORT OF WELDED REPAIR in accordance wsith provisions of the National Board Inspection Code PPL Susquehanna, LLC                                                              G02-147-002, 003, 004
FORM R-1 REPORT OF WELDED REPAIR in accordance wsith provisions of the National Board Inspection Code
: 1. Work performed b NV                                                                                                                                             (Form R No )
: 1. Work performed b NV PPL Susquehanna, LLC (name of repair organization) 707 Salem Blvd. Berwick, PA 18603 (address)
(name of repair organization) 707 Salem Blvd. Berwick, PA 18603                                                                             318013,318033,390136 (P 0 No       Job No etc)
G02-147-002, 003, 004 (Form R No )
318013,318033,390136 (P 0 No Job No etc)
: 3. Location of installation PPL Susquehanna, LLC (ad. ressr PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)
(address)
(address)
: 2. Owner                                                                        PPL Susquehanna, LLC (ad. ressr PPL Susquehanna, LLC
: 4. Unit identification Feedwater Heater Name of original manufacturer (boiler, pressure vessel)
: 3. Location of installation (name) 707 Salem Blvd. Berwick, PA 18603 (address)
: 5. Identifying nos.:
(address)
01-06-54356-1 6362 570250 (mfg serial no)
Feedwater Heater                     Name of original manufacturer                                     Struthers Industries, Inc.
(National Board No (
: 4. Unit identification (boiler, pressure vessel)
(jurisdiction no N BRIC Edition/Addenda:
: 5. Identifying nos.:           01-06-54356-1                           6362                             570250                           1E103A                                2002 (year built)
2001 Original Code of C Construction Code
(other)
: 7. Repair Type:
(mfg serial no)               (National Board No (                 (jurisdiction no 2001 N BRIC Edition/Addenda:                                           2001 (edition)                                                                     (addenda)
Struthers Industries, Inc.
Original Code of Construction for Item:                             ASME Sec. VIII Div. 1                                     1998 Edition w/ 2000 Addenda (name/section/iciision;                                             (edition/addenda)
1E103A (other) 2001 2002 (year built)
Construction Code Used for Repair Performed:                                       ASME Sec. VIII Div. 1                                     1998 Ed. w/ 2000 Add.
(edition)
(name/sectiontdivisron)                                       (edition/acdenda)
(addenda) onstruction for Item:
: 7. Repair Type:              *' Welded                 El Graphite Pressure Equipment                                         El FRP Pressure Equipment
ASME Sec. VIII Div. 1 1998 Edition w/ 2000 Addenda (name/section/iciision; (edition/addenda)
: 8. Description of work:             Welded repair of base metal damage on nozzles N2, N4, and N6.
Used for Repair Performed:
(use supplemental sheet, Form R-4,       rfnecessary)
ASME Sec. VIII Div. 1 1998 Ed. w/ 2000 Add.
Pressure Test, if applied                     N/A                   psi           MAWP               75 int./       15 ext.         psi
(name/sectiontdivisron)
: 9. Replacement Parts:         Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:
(edition/acdenda)  
*' Welded El Graphite Pressure Equipment El FRP Pressure Equipment
: 8. Description of work:
Welded repair of base metal damage on nozzles N2, N4, and N6.
(use supplemental sheet, Form R-4, rf necessary)
Pressure Test, if applied N/A psi MAWP 75 int./
15 ext.
psi
: 9. Replacement Parts: Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:
None (name of part, item number. data report type, mfr's name and identifying stamp)
None (name of part, item number. data report type, mfr's name and identifying stamp)
: 10. Remarks:       Surface examination performed on weld preparation and final weld surfaces.
: 10. Remarks:
CERTIFICATE OF COMPLIANCE I,     --      E         CAh-- ', /           .* certify that to the best of my kno\,.ledge and belief the statements in this report are correct Code.
Surface examination performed on weld preparation and final weld surfaces.
and that all material, construction, and %%orkmanshipon this Repair conforms to the National Board Inspection of Authorization         No.                     5449                       expires on     Novemb         r 3     . 200 National Board "R" Certificate Date 3* /*a       , .?       Z--         PPL     Susquehanna,         LLC         Signed     __.____                             /____             -_--      __---_
I, i*kp),-
(name of repair organization)                                                   ()uthtrizedApre~entative)
/;/e-y
, holding a valid Commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of _
Pennsylvania and employed by Factory Mutual Insurance Company of Johnston. Rhode Island have inspected the work described in this report on
.OO and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board Inspection Code.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
Date C Signed Commissions
*Ikl~landl iaridrtion, and no~m t)
: 2. Owner CERTIFICATE OF COMPLIANCE I,
E CAh-- ', /  
.* certify that to the best of my kno\\,.ledge and belief the statements in this report are correct and that all material, construction, and %%orkmanship on this Repair conforms to the National Board Inspection Code.
National Board "R" Certificate of Authorization No.
5449 expires on Novemb r 3 200 Date 3* /*a  
,.?
Z--
PPL Susquehanna, LLC Signed __.____  
/____
(name of repair organization)
()uthtrized Apre~entative)
CERTIFICATE OF INSPECTION
CERTIFICATE OF INSPECTION
                                                    ,holding a valid Commission issued by The National Board of Boiler and Pressure Vessel I, i*kp),-      *.    /;/e-y of _              Pennsylvania                                and    employed      by Inspectors and certificate of competency issued by the jurisdiction of            Johnston.        Rhode        Island                                                  have Factory Mutual Insurance Company inspected the work described in this report on                                  , .OO                and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board                                Inspection        Code.
'National* Board fic endorsements)...
By signing this certificate, neither the undersigned nor my employer makes                                  any    warranty,    expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor                                  my    employer    shall  be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected                                      with  this  inspection.
p and jurisdiction, and no)
Date                  ,        C Signed                                                                  Commissions
(inspector)  
                                                                                            ,.    *      *Ikl~landl                                  iaridrtion,    andno~m  t)
--&#xfd;
                                                                                                                                          'National*
and Board   fic endorsements)...
jurisdiction, and no)     p (inspector)   --&#xfd;


FORM R-1 REPORT OF WELDED REPAIR in accordance wxith provisions of the National Board Inspection Code
FORM R-1 REPORT OF WELDED REPAIR in accordance wxith provisions of the National Board Inspection Code
: 1. Work performed by'                                          PPL Susquehanna, LLC                                                                       G02-147-005 (Form R No)
: 1. Work performed "2. Owner
(name of repair organization) 318490 707 Salem Blvd. Berwick, PA 18603 (address)                                                    LLC Susquehanna,                            (PO0 No, Job No. etc )
: 3. Location of installation PPL Susquehanna, LLC (name of repair organization) 707 Salem Blvd. Berwick, PA 18603 (address)
PPL "2.Owner                                                                      PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)
PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)
: 3. Location of installation                                                                PPL Susquehanna, LLC (address)                                                  (name) 707 Salem Blvd. Berwick, PA 18603 (address)
G02-147-005 (Form R No) 318490 PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)
: 4. Unit identification       Feedwater Heater                   Name of original manufacturer                                     Struthers Industries, Inc.
: 4. Unit identification Feedwater Heater Name of original manufacturer (boiler pressure vessel)
(boiler pressure vessel) 01-06-54356-3                           6364                         570252                             1E103C                              2002
: 5. Identifying nos.:
: 5. Identifying nos.:                                                                                                                    (olher)                        (year built)
01-06-54356-3 6364 570252 (mfg serial no )
(mfg serial no )             (National Board No               oJurisdiction no) 2001
(National Board No oJurisdiction no)
: 6. NBIC Edition/Addenda:                                           2001                                                                         )adderrda)
: 6. NBIC Edition/Addenda:
(ediliion)                                                                  (addenda)
2001 (edilii Original Code of Construction for Item:
A SME Sec. VIII Div. 1                               1998 Edition w/ 2000 Addenda Original Code of Construction for Item:                                (namelsectionidivision,                                         (editio92addenda)
A Construction Code Used for Repair Performed:
ASME Sec. VIII Div. 1                                     1998 Ed. w/ 2000 Add.
on)
Construction Code Used for Repair Performed:                                                                                                        (edition/addenda)
SME Sec. VIII Div. 1 (namelsectionidivision, ASME Sec. VIII Div. 1 (nametsection/dsvison)
(nametsection/dsvison)
: 7. Repair Type:
El Graphite Pressure Equipment                                    EZ FRP Pressure Equipment
Welded El Graphite Pressure Equipment
: 7. Repair Type:           , Welded
: 8. Description of work:
: 8. Description of work:           Welded repair of base metal damage on nozzle N1 (use supplementai sheet, Form R-4,     i necessary)
Welded repair of base metal damage on nozzle N1 Struthers Industries, Inc.
Pressure Test, if applied                   N/A                   psi           MAWP                 75 int. / 15 ext.               psi
1E103C (olher) 2001 2002 (year built)
: 9. Replacement Parts:       Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:
)adderrda)
(addenda) 1998 Edition w/ 2000 Addenda (editio92addenda) 1998 Ed. w/ 2000 Add.
(edition/addenda)
EZ FRP Pressure Equipment (use supplementai sheet, Form R-4, i necessary)
Pressure Test, if applied N/A psi MAWP 75 int. / 15 ext.
psi
: 9. Replacement Parts: Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:
None (name of par, item number, data repon type, mfr's name and identifying stamp)
None (name of par, item number, data repon type, mfr's name and identifying stamp)
: 10. Remarks:     Surface examination performed on weld preparation and final weld surfaces.
: 10. Remarks:
CERTIFICATE OF COMPLIANCE
Surface examination performed on weld preparation and final weld surfaces.
    --                                  /.   ,certify' that to the best of my knowledge and belief the statements in this report are correct and that all material, construction, and workmanship on this Repair conforms to the National Board Inspection Code.
CERTIFICATE OF COMPLIANCE  
National Board "R" Certificate of Authorization No.                                 5449                     expires on November 3 ,1_200 Date 3/1Z e . ,o.0 72                 PPL Susquehanna. LLC                     Signed (name of repair orwanizalron)                                             (!u   rrize,,   presentatise)
/.,certify' that to the best of my knowledge and belief the statements in this report are correct and that all material, construction, and workmanship on this Repair conforms to the National Board Inspection Code.
CERTIFICATE OF INSPECTION 1_,..--                                 .      holding a valid Commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of co~ipetency issued by the jurisdiction of                                 Pennsylvania                                 and employed by Factor' Mutual Insurance Company                             of           Johnston, Rhode Island                                                             have inspected the work described in this report on '.Y -                 -3     , 2- 04.           and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board Inspection Code.
National Board "R" Certificate of Authorization No.
5449 expires on November 3  
,1_200 Date 3/1Z e  
.,o.0 72 PPL Susquehanna. LLC Signed (name of repair orwanizalron)
( !u rri ze,,
presentatise)
CERTIFICATE OF INSPECTION 1_,..--
holding a valid Commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of co~ipetency issued by the jurisdiction of Pennsylvania and employed by Factor' Mutual Insurance Company of Johnston, Rhode Island have inspected the work described in this report on '.Y -
-3  
, 2- 0 4.
and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board Inspection Code.
By signing this certificate, neither the undersigned nor my employer makes an), warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my' employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes an), warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my' employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
Date         3,   ,d . 0 .Signed                                                                 Commissions                 /,..-         '5       /
Date 3,  
(inspect                                                       (National Board (incl endorse nents),
,d.
0.Signed Commissions  
/,..-
5  
/
(inspect (National Board (incl endorse nents),
and jurisdiction, and no)
and jurisdiction, and no)
PPL Susquehanna, LLC (address) by' (PO0 No, Job No. etc )


149A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 04-Jan-2001
149A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                         PPL Susquehanna, LLC                                         Date                          04-Jan-2001 Name Two North Ninth St., Allentown, PA 18101                                       Sheet              1        Of                    1 Address
: 1. Owner
: 2. Plant                Susquehanna Steam Electric Station                                    Unit                                 One Name WO's: C60007 & C60008 DCP's: 94-3023B & C Service Order: 140747-C PO Box 467 / 707 Salem Blvd., Berwick, PA 18603                                                      Repair Organization P.O No- Job No, etc.
: 2. Plant PO PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Box 467 / 707 Salem Blvd., Berwick, PA 18603 Address
Address Type Code Symbol Stamp                           None
: 3. Work Performed by PPL Susquehanna, LLC.
: 3. Work Performed by                    PPL Susquehanna, LLC.
Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 04-Jan-2001 1
Name Authorization No.                             N/A Two North Ninth St., Allentown, PA 18101 Address Expiration Date                           N/A
Of 1
: 4. Identification of System                                             1t49A-.II,   'NeiUUdl       I tCdL r*,XlI iuV0 III           19     71     Edition,       thru W'72         Addenda,         N/A             Code Case
One WO's: C60007 & C60008 DCP's: 94-3023B & C Service Order: 140747-C Repair Organization P.O No-Job No, etc.
: 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19               89 Ed. No Ad.
Type Code Symbol Stamp None Authorization No.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME Repaired,             Code National Other             Year           Replaced, or         Stamped Name of          Manufacturer           Board Name of                                                            No.               Identification         Built         Replacement           (Yes or Component              Manufacturer            Serial No.                                                    Bul                                   No)
N/A Expiration Date N/A
Componentdetiiaton General Electric       D90450-001D             N/A                 1E217B             1990           Replaced               No RHR Motor Oil Cooler 94G620-001-05             N/A                 1E217B             1994           Replacement             No RHR Motor Oil Cooler       General Electric General Electric       D90451-001D             N/A                 1E217C               1990           Replaced               No RHR Motor Oil Cooler General Electric     94G620-001-07             N/A                 1E217C               1994         Replacement             No RHR Motor Oil Cooler 94G620-001-06             N/A                 1E217D               2000           Repaired               No RHR Motor Oil Cooler      General Electric
: 4. Identification of System 1t49A-.II,  
: 7. Description of Work                   Replacement & Repair of RHR Motor Oil Coolers made of AL6XN materials.
'NeiUUdl I tCdL r*,XlI iuV0
: 8. Tests Conducted:       Hydrostatic     E     Pneumatic         R]     Nominal Operating Pressure                 -1 Other     E-     Pressure             300       psi       Test Temp.         Ambient           &deg;F (2) informa NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/ in. x 11 in.,
: 5. (a) Applicable Construction Code III 19 71
of sheets is tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number recorded at the top of this form.
: Edition, thru W'72
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 Ed. No Ad.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or Componentdetiiaton Bul No)
RHR Motor Oil Cooler General Electric D90450-001D N/A 1E217B 1990 Replaced No RHR Motor Oil Cooler General Electric 94G620-001-05 N/A 1E217B 1994 Replacement No RHR Motor Oil Cooler General Electric D90451-001D N/A 1E217C 1990 Replaced No RHR Motor Oil Cooler General Electric 94G620-001-07 N/A 1E217C 1994 Replacement No RHR Motor Oil Cooler General Electric 94G620-001-06 N/A 1E217D 2000 Repaired No
: 7. Description of Work Replacement & Repair of RHR Motor Oil Coolers made of AL6XN materials.
: 8. Tests Conducted:
Hydrostatic E Pneumatic R]
Nominal Operating Pressure  
-1 Other E-Pressure 300 psi Test Temp.
Ambient  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/
in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 04-Jan-2001 (12/82)


I--
I--
FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         Motor Oil Coolers were replaced during Unit 1, Cycle 9, and should have been included in the Unit I, 91h Outage Summary Report. The repair 1E217D Motor Oil was completed during the Unit I, 12'h RIO, and should have been included in the Unit I, 12 Outage Summary Report.
: 9. Remarks Motor Oil Coolers were replaced during Unit 1, Cycle 9, and should have been included in the Unit I, 91h Outage Summary Report. The repair 1E217D Motor Oil was completed during the Unit I, 12'h RIO, and should have been included in the Unit I, 12 Outage Summary Report.
This condition is documented on Deficiency Report CR-266792.
This condition is documented on Deficiency Report CR-266792.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this             repairtreplacement       conforms to the rules of the ASME Code, Section Xl.                                                                       repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                               N/A Signed1 J$         ... _,            .,                                      Date         Z         *,2001
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this repairtreplacement conforms to the rules of the ASME Code, Section Xl.
                &iOwnep6rOwneisJDe/aneTide         Supv. . Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by               FACTORY MUTUAL INSURANCE CO.                                 of JOHNSTON, RHODE ISLAND                                                                       have inspected the components described in this Owners Report during the period Aug. 2-3 4                     l/pP6               to         ',V-. 9*7"   2.0.: ,/     , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this
N/A Expiration N/A Signed1 J$
            ,                                                          Commissions NVS A7-2.,                 &#xa3;-rg/VA'     A     24,*
Date Z  
Inspector's Signot1'e                                               National Board, State, Province, and Endorsements Date             A/.)je'     ,        200/
*,2001  
&iOwnep6r OwneisJDe/aneTide Supv.. Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owners Report during the period Aug. 2-3 4 l/pP6 to  
',V-. 9*7" 2.0.:  
,/  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions NVS A7-2.,  
&#xa3;-rg/VA' A
24,*
Inspector's Signot1'e National Board, State, Province, and Endorsements Date A/.)je' 200/


149CI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Date Sheet Address Susquehanna Steam Electric Station Name Unit 04/25/2002 1
: 1. Owner                        PPL Susquehanna, LLC                                     Date                           04/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                      Sheet            1           of                     1ON Address
of ONE 769 Salem Blvd, Berwick, PA 18603
: 2. Plant                Susquehanna Steam Electric Station                                Unit                                ONE Name ECO 179459, PCWO 345105 769 Salem Blvd, Berwick, PA 18603 Address                                                            Repair Organization P.O No., Job No., etc
: 3. Work Performed by Address PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.
: 3. Work Performed by                   PPL Susquehanna, LLC                               Type Code Symbol Stamp                          None Name 769 Salem Blvd, Berwick, PA 18603                                     Authorization No.                           N/A Address Expiration Date                             N/A
Expiration Date
: 4. Identification of System                               RESIDUAL HEAT REMOVAL SYSTEM 149C CLASS I
: 4. Identification of System RESIDUAL HEAT REMOVAL SYSTEM 149C CLASS I
: 5. (a) Applicable Construction Code         Asme Section III     19   71     Edition,     Winter 72         Addenda,         N-411             Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19         89                   NO ADDENDA
: 5. (a) Applicable Construction Code Asme Section III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                  Repaired,              Code Board                Other            Year          Replaced, or            Stamped Name of                  Name of            Manufacturer Component              Manufacturer            Serial No.          No.            Identification        Built        Replacement              (Yes No) or PIPE SUPPORT                BECHTEL                  N/A            N/A          SPDCA117-H14            1982            REPLACED                  NO PACIFIC MECH SNUBBER                SCIENTIFIC                13470            N/A          SPDCA117-H14            1981          REPLACED                  N/A 4                      4                  I              I                      -I-          1                        1 4                      4                                                        -            1                        1-I                      I                                                          -r          i                        1
: Edition, Winter 72
: 7. Description of Work                                         REMOVE SNUBBER / NO REPLACEMENT
: Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
: 8. Tests Conducted:       Hydrostatic     E         Pneumatic     E       Nominal Operating Pressure             1 Other       l     Pressure           N/A       psi     Test Temp.             N/A           'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 6. Identification of Components Repaired or Replaced and Replacement Components Code Case
(12182)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 7. Description of Work
: 8. Tests Conducted:
REMOVE SNUBBER / NO REPLACEMENT Hydrostatic E Pneumatic E
Nominal Operating Pressure 1
Other l
Pressure N/A psi Test Temp.
N/A  
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant Name 769 Salem Blvd, Berwick, PA 18603 149CI 1ON ECO 179459, PCWO 345105 Repair Organization P.O No., Job No., etc Type Code Symbol Stamp None N/A N/A ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
PIPE SUPPORT BECHTEL N/A N/A SPDCA117-H14 1982 REPLACED NO PACIFIC MECH SNUBBER SCIENTIFIC 13470 N/A SPDCA117-H14 1981 REPLACED N/A 4
4 I
I
-I-1 1
4 4
-
1 1-I I
-r i
1
(12182)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.
: 9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.
1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 pipincl per ASME 111,1974 Edition, Summer 1975 Addenda, paragraph NB-3630.
1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 pipincl per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this             REPLACEMENT               conforms to the rules of the ASME Code, Section XI.                                                                     repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                                   N/A Signed                                                                         Date         ~       -<~                       20o2-
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
                -owner o =wnr's Desig)   Title   Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by               FACTORY MUTUAL INSURANCE CO.                                       of JOHNSTON, RHODE ISLAND                                 ...                                  have inspected the components described in this Owner's Report during the period                   C.-                           to            _ .7._   - _- O 2-,         , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed Date  
~  
-<~
20o2-
-owner o =wnr's Desig)
Title Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period C.-
_.7 _
to O 2-,  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
L--
L--
  **Z           ,
1
4 1 V:a   V       )A   .27                             Commissions N 9'79 80 A. N T. .3                     NS     P4 -Lo4 Inspector'0Signature                                                 National Board, State, Province, and Endorsements Date                                   20
**Z 4
                                                                                                                                                        )
V:a  
, V  
)A  
.27 Commissions N 9'79 80 A. N T..3 NS P4 -Lo4 Inspector'0Signature National Board, State, Province, and Endorsements Date 20
)


151A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner                          PPL Susquehanna, LLC                                   Date                          06/05/2002 Name Sheet            1            of                      1 769 Salem Blvd.; Berwick, PA 18603 Address Unit                                One
151A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 06/05/2002 1
: 2. Plant              Susquehanna Steam Electric Station Name 769 Salem Blvd.; Berwick, PA 18603                                     DCP: 352940         PCWO 357240 Repair Organization P.O. No., Job No., etc.
of 1
Address
One 769 Salem Blvd.; Berwick, PA 18603 Address DCP: 352940 PCWO 357240 Repair Organization P.O. No., Job No., etc.
: 3. Work Performed by                   PPL Susquehanna, LLC                           Type Code Symbol Stamp                            None Name 769 Salem Blvd.; Berwick, PA 18603                                   Authorization No.                             N/A Address Expiration Date                             N/A
: 3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Type Code Symbol Stamp Authorization No.
: 4. Identification of System                                       CORE SPRAY SYSTEM, 151A --GClass 11 Winter 72        Addenda,        NONE                Code Case
Expiration Date
: 5. (a) Applicable Construction Code         ASME Section III     19 71     Edition, 89 NO ADD.
: 4. Identification of System CORE SPRAY SYSTEM, 151A --GClass 11
(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19
: 5. (a) Applicable Construction Code ASME Section III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                Repaired,            Code Name of                Name of          Manufacturer        Board              Other              Year          Replaced, or          Stamped Component              Manufacturer          Serial No.        No.            Identification        Built        Replacement            (YesNor BECHTEL                N/A            N/A            JD-28-6-1A            1982          REPLACED                YES 318" STAINLESS STEEL TUBING RUN PPL                N/A            N/A            JD-28-6-1A            2002        REPLACEMENT                NO 3/8" STAINLESS STEEL TUBING RUN BECHTEL                N/A            N/A            JD-28-6-1B            1982            REPLACED                YES 3/8" STAINLESS STEEL TUBING RUN PPL                N/A            N/A            JD-28-6-1B            2002        REPLACEMENT                  NO 3/8" STAINLESS STEEL TUBING RUN
: Edition, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 Winter 72
: 7. Description of Work                           Installation of new tubing to relocated instrument rack 1C057
: Addenda, NONE Code Case 89 NO ADD.
: 8. Tests Conducted:      Hydrostatic     0       Pneumatic       D&#xfd;     Nominal Operating Pressure psi     Test Temp.           N/A D-1  &deg;F Other    F      Pressure            N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 6. Identification of Components Repaired or Replaced and Replacement Components
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 7. Description of Work
: 8. Tests Conducted:
Installation of new tubing to relocated instrument rack 1C057 Hydrostatic 0
Pneumatic D&#xfd; Other F
Pressure N/A Nominal Operating Pressure D-1 psi Test Temp.
N/A  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 1 Owner
: 2. Plant None N/A N/A ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (YesN or 318" STAINLESS BECHTEL N/A N/A JD-28-6-1A 1982 REPLACED YES STEEL TUBING RUN 3/8" STAINLESS PPL N/A N/A JD-28-6-1A 2002 REPLACEMENT NO STEEL TUBING RUN 3/8" STAINLESS BECHTEL N/A N/A JD-28-6-1B 1982 REPLACED YES STEEL TUBING RUN 3/8" STAINLESS PPL N/A N/A JD-28-6-1B 2002 REPLACEMENT NO STEEL TUBING RUN (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         NONE Aol.icable Manufacturers Data Reoorts to be attacted C
: 9. Remarks NONE Aol.icable Manufacturers Data Reoorts to be attacted CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               REPLACEMENT             conforms to the rules of the ASME Code, Section XI.                                                                         repair or replacement Type Code Symbol Stamp                                                                     N/A Certificate of Authorization No.                   N/A                     Expiration                                     N/A Signed             ,"--                                                          Date                           -              , 20c, "--
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
owno n Oeesilee,74le       Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
N/A Expiration N/A Signed Date  
, 20c, "--
owno n Oeesilee,74le Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period I-Z-
to 4-7/-71-Z
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
C commissions N 1379 SO A.
1&#xfd; Ig-S f
4 zo4-.
Inspectoe ignature National Board, State, Province, and Endorsements DateJT
,'wE 21 200Z C
(
(
or Province of PENNSYLVANIA                        and employed by              FACTORY MUTUAL INSURANCE CO.                                        of JOHNSTON, RHODE ISLAND                                                                        have inspected the components described in this Owner's Report during the period          .    ,'-
Q>
I-      Z-                          to            4-7/-71-Z                    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________"__________                                      C          commissions N 1379 SO A.                            1&#xfd; Ig-S,    f 4 zo4-.
Inspectoe    ignature                                                National Board, State, Province, and Endorsements DateJT        ,'wE 21                200Z Q>


153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                          PPL Susquehanna, LLC                                 Date                          04/30/2002 Name 769 Salem Blvd, Berwick, PA 18603                                     Sheet            1          of                    3 Address
: 3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, Address DCP 318280; PCWO 319462, 319466, 319468, 319558. 346328 Repair Organization P.O. No, Job No, etc Type Code Symbol Stamp None DA 18603 Authorization No.
: 2. Plant                Susquehanna Steam Electric Station                                Unit                                  1 Name DCP 318280; PCWO 319462, 319466, 319468, 769 Salem Blvd, Berwick, PA 18603                                        319558. 346328 Address                                                        Repair Organization P.O. No, Job No, etc
N/A Expiration Date N/A
: 3. Work Performed by                    PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name 769 Salem Blvd, Berwick, DA 18603                                     Authorization No.                           N/A Address Expiration Date                           N/A
: 4. Identification of System 153A - STANDBY LIUUIU  
: 4. Identification of System                               153A - STANDBY LIUUIU           ;UNTI RUL         Y> I t-M LL/AZ           II
;UNTI RUL Y> I t-M LL/AZ II
: 5. (a) Applicable Construction Code                   III         19 71     Edition,     thru W'72       Addenda,         See Remark       Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19       89                   Code Case N416-1 6- Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,           Code Board               Other             Year         Replaced, or         Stamped Name of                  Name of          Manufacturer                                                                                 (Yes or Serial No.       No.           Identification         Built         Replacement Component              Manufacturer                                                                                                        No)
: 5. (a) Applicable Construction Code III 19 71
Small Pipe Flanges             Bechtel                 N/A           N/A           SPDCB101-1             1982           REPLACED               Yes HT# C5257         N/A           SPDCB101-1             2002       REPLACEMENT               No Small Pipe Flanges                  PPL LONERGAN             VALVE S/N         N/A           PSV148029A             1979           REPLACED               Yes Spring and Spring Step                                     510138-1-14-1 LONERGAN             VALVE S/N         N/A           PSV148029A             2002       REPLACEMENT               No Spring and Spring Step                                     510138-1-14-1 Bechtel                 N/A           N/A           SPDCB101-2             1982           REPLACED               Yes Small Pipe Flanges PPL             HT# HN051         N/A           SPDCB101-2             2002       REPLACEMENT               No Small Pipe Flanges LONERGAN             VALVE S/N         N/A           PSV148FO29B             1979           REPLACED               Yes Spring and Spring Step                                     510138-1-14-2
: Edition, thru W'72
: Addenda, See Remark Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Code Case N416-1 6-Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Small Pipe Flanges Bechtel N/A N/A SPDCB101-1 1982 REPLACED Yes Small Pipe Flanges PPL HT# C5257 N/A SPDCB101-1 2002 REPLACEMENT No Spring and Spring LONERGAN VALVE S/N N/A PSV148029A 1979 REPLACED Yes Step 510138-1-14-1 Spring and Spring LONERGAN VALVE S/N N/A PSV148029A 2002 REPLACEMENT No Step 510138-1-14-1 Small Pipe Flanges Bechtel N/A N/A SPDCB101-2 1982 REPLACED Yes Small Pipe Flanges PPL HT# HN051 N/A SPDCB101-2 2002 REPLACEMENT No Spring and Spring LONERGAN VALVE S/N N/A PSV148FO29B 1979 REPLACED Yes Step 510138-1-14-2
* SEE REMARKS
: 7. Description of Work
: 7. Description of Work
* SEE REMARKS
: 8. Teests Conducted:
: 8. Teests Conducted:     Hydrostatic     E       Pneumatic     D     Nominal Operating Pressure           t^
Hydrostatic E Pneumatic D
Other       l     Pressure         1400     psi     Test Temp.             72           &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Nominal Operating Pressure t^
(12/82)                          This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
Other l
Pressure 1400 psi Test Temp.
72  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant 04/30/2002 Date Sheet Unit 1
of 3
1 (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         Rerated the piping (SPDCB101-1, 2, 3, 4, 5, 6, 7, 8) pumps (1P208A/B) and valves (PSV148FO29A/B). Replace spring and step spring in PSV's. Replace the pump discharge flanges from 600# to 1500#. Install new (rerate nameplates) with new design pressure of 1500PSI on components.
: 9. Remarks Rerated the piping (SPDCB101-1, 2, 3, 4, 5, 6, 7, 8) pumps (1P208A/B) and valves (PSV148FO29A/B). Replace spring and step spring in PSV's. Replace the pump discharge flanges from 600# to 1500#. Install new (rerate nameplates) with new design pressure of 1500PSI on components.
Piping DCB-101; Valve PSV148FO29A/B. Replaced plunger in 1P208B.
Piping DCB-101; Valve PSV148FO29A/B. Replaced plunger in 1P208B.
Construction Code for LONERGAN:ASME Section III, 1974 Edition thru Winter 1974; Code Case N-1 555 Construction Code for SLC Pumps: ASME Section III, 1968 Edition.
Construction Code for LONERGAN:ASME Section III, 1974 Edition thru Winter 1974; Code Case N-1 555 Construction Code for SLC Pumps: ASME Section III, 1968 Edition.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                       Repair Replacement           conforms to the rules of the ASME Code, Section XI.                                                                        repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.                     N/A                     Expiration                                 N/A Signed                                                                             Date      '\-Z          _ /I.-              .20  O6 Owner orfwner's DesikF,6. Ttle   Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by               FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON, RHODE ISLAND                         .        ..                                  ha~e inspted      the.omponents described in this Owners Report during the period             * -     &J5-         1                 to       S.     _T-   0-. .-            and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code, Section XI.
Type Code Symbol Stamp Repair Replacement conforms to the rules of the repair or replacement N/A Certificate of Authorization No.
N/A Expiration Signed Owner orfwner's DesikF,6. Ttle Supv. - Site Modifications Group Date
'\\-Z
_ /I.-
N/A
.20 O6 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND ha~e ins pted the.omponents described in this Owners Report during the period  
- &J5-1 to S.
_T-0-.
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
( 1 ,&#xfd;4'                     Z           z7                         Commissions       NO79 80 A. N, r. 13-. iNi                   PA C     Ot.
(1,&#xfd;4' Z
lnspectoCoSignature                                                   National Board, State, Province, and Endorsements Date. J'uNv,       I 7               200 Z.
z7 Commissions NO79 80 A. N, r. 13 -. iNi PA C Ot.
                                                                                                                                                          /0q,
lnspectoCoSignature National Board, State, Province, and Endorsements Date. J'uNv, I 7 200 Z.
/0q,


153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
: 1. Owner                         PPL Susquehanna, LLC.                                   Date                          04/30/2002 Name 769 Salem Blvd, Berwick, PA 18603                                       Sheet            2            of                    2 Address Unit 1
: 1. Owner
: 2. Plant                Susquehanna Steam Electric Station Name DCP 318280; PCWO 319462, 319466, 319468, 769 Salem Blvd, Berwick, PA 18603                                        319558, 346328 Address                                                            Repair Organization P.0 No, Job No., etc.
: 2. Plant PPL Susquehanna, LLC.
: 3. Work Performed by                  PPL Susque hanna, LLC.                             Type Code Symbol Stamp                         None Na me 769 Salem Blvd, Berwick, FPA 18603                                     Authorization No.                           N/A Address Expiration Date                             N/A
Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 4. Indentification of System                              153A - STANDBY LIQUID CONTROL SYSTEM CLASS II
: 3. Work Performed by PPL Susque Na 769 Salem Blvd, Berwick, F Address
: 5. (a) Applicable Construction Code                   III           19   71   Edition,   thru W'72         Addenda,         See Remark       Code Case (b) Applicable Edition of Section XI   Utilized for Repairs or Replacements   19   89                   Code Case N416-1
: 4. Indentification of System Date Sheet Unit 04/30/2002 2
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME Repaired,         Code National Other             Year         Replaced, or       Stamped Name of            Manufacturer         Board Name of                                                                          Identification         Built         Replacement         (Yes or Manufacturer            Serial No.          No.
of 2
Component                                                                                                                                    No)
1 DCP 318280; PCWO 319462, 319466, 319468, 319558, 346328 Repair Organization P.0 No, Job No., etc.
VALVE S/N           N/A         PSV148F029B             2002       REPLACEMENT             No Spring and Spring            LONERGAN Step                                       510138-1-14-2 N/A             N/A         SPDCB101-1             1982           REPLACED             Yes Stud Bolt/Nut               Bechtel Stud Bolt         N/A         SPDCB101-1             2002       REPLACEMENT               No Stud Bolt/Nut                  PPL HT#04617; Nut HT#HDF N/A             N/A         SPDCB101-2             1982           REPLACE             Yes Stud Bolt/Nut               Bechtel Stud Bolt         N/A         SPDCB101-2             2002       REPLACEMENT               No Stud Bolt/Nut                  PPL HT#04617; Nut HT#HDF S/N 284222           N/A             1P-208A             1973           REPLACED             Yes SLC Pump "A"                   Union S/N 284222           N/A             1P-208A             2002       REPLACEMENT               No SLC Pump "A"                   Union S/N 284223           N/A             1P-208B             1973           REPLACED             Yes SLC Pump "B"                   Union S/N 284223           N/A             1P-208B             2002       REPLACEMENT               No SLC Pump "B"                    Union N/A             N/A               N/A               1982           REPLACED             Yes Piping Isometrics              Bechtel SPDCB 101-3, 4, 5,
hanna, LLC.
: 6. 7 and 8
Type Code Symbol Stamp None me PA 18603 Authorization No.
N/A Expiration Date N/A 153A - STANDBY LIQUID CONTROL SYSTEM CLASS II (a) Applicable Construction Code III 19 71
: Edition, thru W'72
: Addenda, See Remark Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 Code Case N416-1
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Spring and Spring LONERGAN VALVE S/N N/A PSV148F029B 2002 REPLACEMENT No Step 510138-1-14-2 Stud Bolt/Nut Bechtel N/A N/A SPDCB101-1 1982 REPLACED Yes Stud Bolt/Nut PPL Stud Bolt N/A SPDCB101-1 2002 REPLACEMENT No HT#04617; Nut HT#HDF Stud Bolt/Nut Bechtel N/A N/A SPDCB101-2 1982 REPLACE Yes Stud Bolt/Nut PPL Stud Bolt N/A SPDCB101-2 2002 REPLACEMENT No HT#04617; Nut HT#HDF SLC Pump "A" Union S/N 284222 N/A 1P-208A 1973 REPLACED Yes SLC Pump "A" Union S/N 284222 N/A 1 P-208A 2002 REPLACEMENT No SLC Pump "B" Union S/N 284223 N/A 1 P-208B 1973 REPLACED Yes SLC Pump "B" Union S/N 284223 N/A 1P-208B 2002 REPLACEMENT No Piping Isometrics Bechtel N/A N/A N/A 1982 REPLACED Yes SPDCB 101-3, 4, 5,
: 6. 7 and 8 5.


153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC.
: 1. Owner                        PPL Susquehanna, LLC.                                   Date                          04/30/2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet            3            of                      3 Address
Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address 3, Work Performed by PPL Susquehanna, LLC.
: 2. Plant                Susquehanna Steam Electric Station                             Unit                                   1 Name DCP 318280; PCWO 319462, 319466, 319468, 769 Salem Blvd, Berwick, PA 18603                                      319558, 346328 Address                                                          Repair Organization P.O. No., Job No., etc 3, Work Performed by                  PPL Susquehanna, LLC.                            Type Code Symbol Stamp                           None Name 769 Salem BlVd, Berwlck, DA 1 8bU3                                   Authorization No.                             NIA Address Expiration Date                             N/A
Name 769 Salem BlVd, Berwlck, Address Date Sheet Unit 04/30/2002 3
: 4. Indentification of System                           153A - STANDBY LIQUILD CONTROL SYS I EM CLASS II
of 3
: 5. (a) Applicable Construction Code                 III         19   71     Edition,     thru W'72       Addenda,         See Remark           Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19       89                   Code Case N416-1
1 DCP 318280; PCWO 319462, 319466, 319468, 319558, 346328 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp None DA 1 8bU3 Authorization No.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Manufacturer         Board               Other             Year           Replaced, or           Stamped Name of                Name of Serial No.         No.           Identification         Built         Replacement             (Yes or Component            Manufacturer No)
NIA Expiration Date N/A
Piping Isometrics               PPL                   N/A           N/A                 N/A             2002       REPLACEMENT                 No SPDCB10I-3, 4, 5, 6, 7 and 8 PLUNGER                     Union             SIN 284223           N/A             1P-208B             1971           REPLACED                 Yes PLUNGER                     Union             SIN 284223           N/A             1P-208B             2002       REPLACEMENT                 No SPDCBIOI-H37                 Bechtel                 N/A           N/A         SPDCB101-H37           1982           REPAIRED                 No
: 4. Indentification of System 153A - STANDBY LIQUILD CONTROL SYS I EM CLASS II
: 5. (a) Applicable Construction Code III 19 71
: Edition, thru W'72
: Addenda, See Remark Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Code Case N416-1
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Piping Isometrics PPL N/A N/A N/A 2002 REPLACEMENT No SPDCB10I-3, 4, 5, 6, 7 and 8 PLUNGER Union SIN 284223 N/A 1P-208B 1971 REPLACED Yes PLUNGER Union SIN 284223 N/A 1 P-208B 2002 REPLACEMENT No SPDCBIOI-H37 Bechtel N/A N/A SPDCB101-H37 1982 REPAIRED No
: 1. Owner
: 2. Plant


161 B-Ill FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
161 B-Ill FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 06/05/2002 1
: 1. Owner                          PPL Susquehanna, LLC                                   Date                           06/05/2002 Name 769 Salem Blvd.; Berwick, PA 18603                                     Sheet            1          of Address
of One 769 Salem Blvd.; Berwick, PA 18603 Address
: 2. Plant                Susquehanna Steam Electric Station                                Unit                                One Name 769 Salem Blvd.; Berwick, PA 18603                                       PCWO 267546 & 189828 Address                                                            Repair Organization P.0 No., Job No., etc
: 3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address PCWO 267546 & 189828 Repair Organization P.0 No., Job No., etc Type Code Symbol Stamp None Authorization No.
: 3. Work Performed by                  PPL Susquehanna, LLC                              Type Code Symbol Stamp                           None Name 769 Salem Blvd.; Berwick, PA 18603                                    Authorization No.                             N/A Address Expiration Date                            N/A
Expiration Date N/A N/A
: 4. Identification of System                                   REACTOR WATER CLEANUP, 161B -- Class III
: 4. Identification of System REACTOR WATER CLEANUP, 161B -- Class III
: 5. (a) Applicable Construction Code             Draft ASME       19   68   Edition,                       Addenda,        NONE                Code Case Pump & Valve (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19       89,NO ADD.
: 5. (a) Applicable Construction Code Draft ASME 19 68
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,               Code Name of                 Name of           Manufacturer       Board               Other             Year           Replaced, or           Stamped Component             Manufacturer           Serial No.         No.           Identification         Built         Replacement             (Yes or No)
: Edition, Pump & Valve (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89,NO ADD.
PROXIMITY PROBE                 HAYWARD             U12H91823           N/A         SPARE(PUMP)             1991           REPLACED                 NO (4 EA.)                           TYLER               (PUMP MOTOR)
: 6. Identification of Components Repaired or Replaced and Replacement Components
PLUG (4 EA) -1/2"                 BONNEY                 N/A             N/A         (1)--HT. # 9162         1998       REPLACEMENT                 NO (3) - HT. # 9204         1999 1/4"PROXIMITY                 HAYWARD             U12H91823           N/A         SPARE (PUMP)             1991           REPLACED                 NO PROBE -(2 EA.)                     TYLER               (PUMP MOTOR)
: Addenda, NONE
PLUG (2EA) - 1/4"                 BONNEY                                 N/A           HEAT #CK43             1984       REPLACEMENT                 NO 1                     t                 1-             1                                     1                         t
: 7. Description of Work
: 7. Description of Work          REPLACED PROXIMITY PROBES WITH PIPE PLUGS ON PUMP MOTOR U12H91823
: 8. Tests Conducted:
: 8. Tests Conducted:      Hydrostatic    E        Pneumatic      D      Nominal Operating Pressure              Dl.F Other    El      Pressure    _        _    psi      Test Temp.                                        NONE CONDUCTED NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/ in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
REPLACED PROXIMITY PROBES WITH PIPE PLUGS ON PUMP MOTOR U12H91823 Hydrostatic E Pneumatic D
(12/82)                         This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
Nominal Operating Pressure Other El Pressure psi Test Temp.
Dl
.F NONE CONDUCTED NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/
in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant Code Case ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
PROXIMITY PROBE HAYWARD U12H91823 N/A SPARE(PUMP) 1991 REPLACED NO (4 EA.)
TYLER (PUMP MOTOR)
PLUG (4 EA) -1/2" BONNEY N/A N/A (1)--HT. # 9162 1998 REPLACEMENT NO (3) - HT. # 9204 1999 1/4"PROXIMITY HAYWARD U12H91823 N/A SPARE (PUMP) 1991 REPLACED NO PROBE -(2 EA.)
TYLER (PUMP MOTOR)
PLUG (2EA) - 1/4" BONNEY N/A HEAT #CK43 1984 REPLACEMENT NO
1
t 1-1 1
t (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks NO CODE DATA REPORTS ARE APPLICABLE TO THE PIPE PLUGS USED TO REPLACE THE PROXIMITY PROBES IN ACCORDANCE WITH PCWO's 189828 & 267546, AND DCP 224005 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               REPLACEMENT           conforms to the rules of the ASME Code, Section XI.                                                                     repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                               N/A Signed           ,,,                                                            Date                                       200-L.
: 9. Remarks NO CODE DATA REPORTS ARE APPLICABLE TO THE PIPE PLUGS USED TO REPLACE THE PROXIMITY PROBES IN ACCORDANCE WITH PCWO's 189828 & 267546, AND DCP 224005 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
0Oter or Owner's D Ir   Title   Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
                                                                                                                                                      )
N/A Expiration N/A Signed Date 200- L.
or Province of PENNSYLVANIA                     and employed by               FACTORY MUTUAL INSURANCE CO.                                   of JOHNSTON, RHODE ISLAND                                                                     have insp ct d the components described in this Owner's Report during the period                 -      -I         )               to                 II  (              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
0Oter or Owner's D Ir Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have insp ct d the components described in this Owner's Report during the period II
-I
(
)
to  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
CJD7?-i                                                 Commissions       Nk? 7'700 A.                         F.4 ZZt    o0 Inspector's 11fgfature                                               National Board, State, Province, and Endorsements Date U'U" a       Z1                20 0 '2.
C JD7?-i Commissions Nk? 7'700 A.
F.4 Z Zt o0 Inspector's 11fgfature National Board, State, Province, and Endorsements Date U'U" a Z 1 20 0 '2.
)
9
9


162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                        PPL Susquehanna, LLC                                     Date                            4/25/2002 Name Two North Ninth St., Allentown, PA 18101                                 Sheet                        of                      3 Address
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
: 2. Plant                Susquehanna Steam Electric Station                                Unit                                 One Name PCWO 345780, 345876, 345886, 345891 769 Salem Blvd, Berwick, PA 18603                                        DCP 316329, 316330, 316331, 316332 Address                                                            Repair Organization P.O. No., Job No.. etc.
: 4. Identification of System 162A, F Date Sheet Unit 4/25/2002 of 3
: 3. Work Performed by                    PPL Susquehanna, LLC                              Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                                  Authorization No.                             N/A Address Expiration Date                             N/A
One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No., Job No.. etc.
: 4. Identification of System                                            162A, FReactor Vessel; Class 1
Type Code Symbol Stamp None Authorization No.
: 5. (a) Applicable Construction Code                 I11           19 71     Edition,     thru S' 71       Addenda,            1535-2          Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
N/A Expiration Date N/A Reactor Vessel; Class 1
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                Repaired,            Code Name of                  Name of          Manufacturer        Board              Other              Year          Replaced, or          Stamped Component              Manufacturer          Serial No.          No.          Identification          Built        Replacement            (Yes or No) 26" MSIV            Atwood & Morrill            1-221            NA          HV141FO22A              1974            Replaced              Yes 26" MSIV            Atwood & Morrill            1-221            NA            HV141F022A              1974            Repaired              Yes Super Bolts ( torque      Atwood & Morrill            N/A            NA            HV141FO22A              2001          Replacement              No nut assemblies)
: 5. (a) Applicable Construction Code I11 19 71
Poppet                  Welding            245951-5            NA            HV141FO22A              2001          Replacement              Yes Services, Inc Bonnet Cover          Atwood & Morrill          H3391-3            NA            HV141F022A              2001          Replacement              Yes Pilot Poppet          Atwood & Morrill          54682-5            NA            HV141F022A            2001          Replacement              Yes Body/Bonnet Stud        Atwood & Morrill              NA            NA            HV141FO22A            2001          Replacement              No
: Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 7. Description of Work                               Improve seating characteritics and maintainability of MSIVs
: 6. Identification of Components Repaired or Replaced and Replacement Components
: 8. Tests Conducted:         Hydrostatic   ElJ     Pneumatic       1     Nominal Operating Pressure             F-                 SE-100-002 Other 0           Pressure           1037     psi     Test Temp.             147         'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 7. Description of Work
(12/82)                          This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: Addenda, 1535-2 Code Case Improve seating characteritics and maintainability of MSIVs
: 8. Tests Conducted:
Hydrostatic ElJ Pneumatic 1
Nominal Operating Pressure F-SE-100-002 Other 0
Pressure 1037 psi Test Temp.
147  
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner Name Two North Ninth St., Allentown, PA 18101
: 2. Plant ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 1-221 NA HV141FO22A 1974 Replaced Yes 26" MSIV Atwood & Morrill 1-221 NA HV141F022A 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141FO22A 2001 Replacement No nut assemblies)
Poppet Welding 245951-5 NA HV141FO22A 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-3 NA HV141F022A 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-5 NA HV141F022A 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO22A 2001 Replacement No (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.
: 9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.
National Board Forms NR-1 and ASME Forms N-2 are attached.
National Board Forms NR-1 and ASME Forms N-2 are attached.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               Repair/Replacement       conforms to the rules of the ASME Code, Section X1.                                                                       repair or replacement Type Code Symbol Stamp                                                                     N/A Certificate of Authorization No.                     N/A                     Expiration                                   N/A Sigd                                                                          Date                       &;             20' V 2
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair/Replacement conforms to the rules of the ASME Code, Section X1.
                  ,Owne(r Owper's Des )e, Ttle Supv. - Site Modifications Group r(N>
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by               FACTORY MUTUAL INSURANCE CO.                                       of JOHNSTON, RHODE ISLAND                                                                       have inspected the components described in this Owner's Report during the period         Z, - Z 8- 0Z                               to     6 - *4- 0 7.                         , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
N/A Expiration N/A Sig d Date &;
20' V 2  
,Owne(r Owper's Des )e, Ttle Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period Z, - Z 8- 0Z to 6 -
*4-0 7.  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(9J?               ""z     's                                       Commissions NS 7980                 A,.,r. UAI"             PA *Z.-0+
(9J?  
InspectcK Signature                                                 National Board, State, P'rovince, and Endorsements Date           t-   Z*                   2002-
""z  
's Commissions NS 7980 A,.,r. UAI" PA *Z.-0+
InspectcK Signature National Board, State, P'rovince, and Endorsements Date t-Z*
2002-r(N>


162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                       PPL Susquehanna, LLC                                   Date                          4/25/2002 Name Two North Ninth St., Allentown, PA 18101                               Sheet            2          of                      3 Address
: 1. Owner
: 2. Plant              Susquehanna Steam Electric Station                              Unit                               One Name PCWO 345780, 345876, 345886, 345891 769 Salem Blvd, Berwick, PA 18603                                      DCP 316329, 316330, 316331, 316332 Address                                                          Repair Organization P.O. No.. Job No., etc.
: 2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 3. Work Performed by                PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                              Authorization No.                             N/A Address Expiration Date                             N/A
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 4/25/2002 2
: 4. Identification of System                                           162A, Reactor Vessel; Class 1
of 3
: 5. (a) Applicable Construction Code               III         19   71   Edition,     thru S' 71       Addenda,           1535-2           Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19     89
One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No.. Job No., etc.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Name of                 Name of           Manufacturer       Board               Other             Year           Replaced, or         Stamped Component             Manufacturer           Serial No.         No.         Identification         Built         Replacement             (Yes or No) 26" MSIV             Atwood & Morrill           2-221           NA         HV141F022B             1974             Replaced               Yes 26" MSIV           Atwood & Morrill           2-221           NA         HV141F022B             1974             Repaired               Yes Super Bolts ( torque     Atwood & Morrill             N/A             NA         HV141FO22B             2001         Replacement               No nut assemblies)
Type Code Symbol Stamp None Authorization No.
Poppet                 Welding             245951-4           NA         HV141F022B             2001         Replacement               Yes Services, Inc Bonnet Cover         Atwood & Morrill         H3391-5           NA         HV141FO22B             2001         Replacement               Yes Pilot Poppet         Atwood & Morrill         54682-7           NA         HV141FO22B             2002           Replacement               Yes Body/Bonnet Stud         Atwood & Morrill             NA             NA         HV141F022B             2001           Replacement               No 26" MSIV           Atwood & Morrill           3-221           NA         HV141FO22C             1974             Replaced               Yes 26" MSIV           Atwood & Morrill           3-221           NA         HV141FO22C             1974             Repaired               Yes Super Bolts ( torque     Atwood & Morrill             N/A             NA         HV141 F022C           2001           Replacement               No nut assemblies)
N/A Expiration Date N/A
Poppet                 Welding             245951-8             NA         HV141FO22C             2001           Replacement               Yes Services, Inc
: 4. Identification of System 162A, Reactor Vessel; Class 1
: 5. (a) Applicable Construction Code III 19 71
: Edition, thru S' 71
: Addenda, 1535-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 2-221 NA HV141F022B 1974 Replaced Yes 26" MSIV Atwood & Morrill 2-221 NA HV141F022B 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141FO22B 2001 Replacement No nut assemblies)
Poppet Welding 245951-4 NA HV141F022B 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-5 NA HV141FO22B 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-7 NA HV141FO22B 2002 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141F022B 2001 Replacement No 26" MSIV Atwood & Morrill 3-221 NA HV141FO22C 1974 Replaced Yes 26" MSIV Atwood & Morrill 3-221 NA HV141FO22C 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141 F022C 2001 Replacement No nut assemblies)
Poppet Welding 245951-8 NA HV141FO22C 2001 Replacement Yes Services, Inc


162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station 769 Salem Name Blvd, Berwick, PA 18603 Address
: 1. Owner                        PPL Susquehanna, LLC                                   Date                            4/25/2002 Name Two North Ninth St., Allentown, PA 18101                               Sheet            3            of                      3 Address Susquehanna Steam Electric Station                             Unit                                One
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 4/25/2002 3
: 2. Plant Name PCWO 345780, 345876, 345886, 345891 769 Salem Blvd, Berwick, PA 18603                                      DCP 316329, 316330, 316331, 316332 Address                                                          Repair Organization P.O. No., Job No., etc.
of 3
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                             None Name Two North Ninth St., Allentown, PA 18101                              Authorization No.                               N/A Address Expiration Date                               N/A
One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No., Job No., etc.
: 4. Identification of System                                             ioLMk, Reactor vessel;         ,Clas I
Type Code Symbol Stamp None Authorization No.
: 5. (a) Applicable Construction Code                 III         19   71   Edition,   thru S' 71       Addenda,           1535-2           Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19     89
N/A Expiration Date N/A
: 6. Identification of Components Repaired or Replaced and Replacement Components T                     r           1 ASME Code National                                               Repaired,           Stamped Board                                              Replaced, or Name of                Name of          Manufacturer                            Other              Year          Replacement           (Yes or Serial No.          No.          Identification          Built                                  No)
: 4. Identification of System ioLMk, Reactor vessel;,Clas I
Component            Manufacturer Bonnet Cover           Atwood & Morrill         H3391-8             NA         HV141FO22C             2001           Replacement             Yes Pilot Poppet         Atwood & Morrill           54682-8           NA         HV141FO22C             2001           Replacement             Yes Body/Bonnet Stud         Atwood & Morrill             NA               NA         HV141 F022C             2001         Replacement               No 26" MSIV           Atwood & Morrill           4-221             NA         HV141FO22D               1974           Replaced               Yes 26" MSIV           Atwood & Morrill           4-221             NA         HV141F022D               1974             Repaired             Yes Super Bolts ( torque       Atwood & Morrill             N/A             NA         HV141F022D               2001         Replacement               No nut assemblies)
: 5. (a) Applicable Construction Code III 19 71
Poppet                 Welding             245951-9             NA         HV141FO22D               2001         Replacement             Yes Services, Inc Bonnet Cover           Atwood & Morrill         H3391-9             NA         HV141F022D               2001         Replacement             Yes Pilot Poppet         Atwood & Morrill           54682-9           NA         HV141F022D               2001         Replacement             Yes Body/Bonnet Stud         Atwood & Morrill             NA               NA         HV141FO22D             2001         Replacement               No
: Edition, thru S' 71
: Addenda, 1535-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.
T r
1 National Board No.
Other Identification Year Built
: Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)
Bonnet Cover Atwood & Morrill H3391-8 NA HV141FO22C 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-8 NA HV141FO22C 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141 F022C 2001 Replacement No 26" MSIV Atwood & Morrill 4-221 NA HV141FO22D 1974 Replaced Yes 26" MSIV Atwood & Morrill 4-221 NA HV141F022D 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F022D 2001 Replacement No nut assemblies)
Poppet Welding 245951-9 NA HV141FO22D 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-9 NA HV141F022D 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-9 NA HV141F022D 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO22D 2001 Replacement No
: 1. Owner
: 2. Plant


FORM NR-1               REPORT OF REPAIR A                     MODIFICATION El                   OR REPLACEMENT                       ]
FORM NR-1 REPORT OF REPAIR A MODIFICATION El OR REPLACEMENT  
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS 1.Work performed by               Continental           Field Systems,                   Inc                               3218 (name of NR certificate holder)                                           (P.O. no., job no., etc.)
]
23 Westgate Blvd.                       Savannah,           GA 31405 (address)
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 2. Owner           PPL       LLC (name) 2 North Ninth Street,                       Allentown,               PA 18101 (address)
: 1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
: 3. Name, address and identification of nuclear power plant                     Susquehanna Steam Electric 5 Niles North of Berwick,                             PA                     Salem Twp,             PA
(P.O. no., job no., etc.)
: 4. System           1-62A         HV141F022A                                           Main Steam
23 Westgate Blvd.
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification                                                     Construction Code                             Activity Type of         Mfg.           Mfg. Nat'l Bd. Jurisd.       Other       Year       Name/           Edition/       Code         Code         Repair/
: Savannah, GA 31405 (address)
No     Item         Name       Serial No. No.       No.                   Built     Section/       Addenda       Case(s)         Class         Mod/
: 2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
Division                                                   Replace 2
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Niles North of Berwick, PA Salem Twp, PA
: 4. System 1-62A HV141F022A Main Steam
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
9 10 11 12
9 10 11 12
: 5. b: Items Intstalled During Replacement Activities                     See Attached Identification                                                             Construction Code Type of         Installed or. Mfg.       Mfg         Nat'l Bd.       Jurisd     Other       Year       Name/       Edition/           Code)       Code Item             Replaced       Name     Serial No.       No.           No                 Built     Section/     Addenda         Case(s)       Class 5a Item No.                                                                                 Division
: 5. b: Items Intstalled During Replacement Activities See Attached Identification Construction Code Type of Installed or.
: 6. ASME Code Section )GIapplicable for inservice inspection:                       1989                     N/A                         N/A (edition)                   (addenda)                   (Code Caess))
Mfg.
: 7. ASME Code Section XI used for repairs, modifications, or replacements:                           19q89q             N/A                     N/A (edition)         (addenda)               (Code Cases(s))
Mfg Nat'l Bd.
: 8. Construction Cdusdfrrepairs,           modifications, orreplacements:                 191S7                                       N/
Jurisd Other Year Name/
C(edition)                                                                                                 (addenda)               (Code Cases(s))
Edition/
: 9. Design responsibilities:         Atwood & Morrill Co.
Code)
: 10. Tests conducted: hydrostatic D]           pneumatic []       design pressure ID           pressure N /A         psi   Code Case(s)
Code Item Replaced Name Serial No.
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                               Rev. 8
No.
: 11. Description of work:          See Attarhpdl ue.pDescriptioneofrework:ed (use of properly identified additional sheetqs) or sketch(es) is acceptable)
No Built Section/
: 12. Remarks:-       See Attached CERTIFICATE OF COMPLIANCE I,     David McCathie               certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
Addenda Case(s)
National Board Certificate of Authorization No.             NR-86                     to use the "NR" stamp expires 5/25                         2003 NR Certificate Holder Continental Field Systems,                                     Inc Date 6 11         2002 Signed L 4                     71"' 6M J                                     Quality Control Manager (authorized representative)                                               (tite)
Class 5a Item No.
CERTIFICATE OF INSPECTION I,   ,/j,"a.AM r, 0o96C.J" 1U7, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of P                       N/& Y. Vq-4N-4                         and employed by 9CTO.Y MuTuA.L :rNs4Avrc&h                             <:,tlPANy                         of JOHP4 ,o                     .roN                           have inspected the repair, modification or replacement described in this report on                         .            ,    0     .-    and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.
Division
: 6. ASME Code Section )GI applicable for inservice inspection:
1989 N/A N/A (edition)
(addenda)
(Code Caess))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:
19q89q N/A N/A (edition)
(addenda)
(Code Cases(s))
: 8. Construction Cdusdfrrepairs, modifications, orreplacements:
191S7 N/
C(edition)
(addenda)
(Code Cases(s))
: 9. Design responsibilities:
Atwood & Morrill Co.
: 10. Tests conducted: hydrostatic D]
pneumatic [] design pressure ID pressure N /A psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
 
ue.pDescriptioneofrework:ed (use of properly identified additional sheetqs) or sketch(es) is acceptable)
: 12. Remarks:-
See Attached CERTIFICATE OF COMPLIANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-86 to use the "NR" stamp expires 5/25 2003 NR Certificate Holder Continental Field Systems, Inc Date 6 11 2002 Signed L 4 71"' 6M J Quality Control Manager (authorized representative)
(tite)
CERTIFICATE OF INSPECTION I,  
,/j,"a.AM r, 0o96C.J" 1U7, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of P N/& Y. Vq-4N-4 and employed by 9CTO.Y MuTuA.L :rNs4Avrc&h  
<:,tlPANy of JOHP4,o  
.roN have inspected the repair, modification or replacement described in this report on 0
and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
DateTW( +" reO,                 Signed A.,/g               0.                 n -,-           CommissionsAJ798OAIJT. TAS /*4 Zo4 (mspetora                             (National Board (incl. ecdorsernents), jurisdiction, and no.)
DateTW(  
+" re O, Signed A.,/g
: 0.
n -,-
CommissionsAJ798OAIJT. TAS /*4 Zo4 (mspetora (National Board (incl. ecdorsernents), jurisdiction, and no.)
See Attarhpdl work:
: 11. Description of


Form NR-1 Attachment                                    Report of Repair / Replacement Worked Performed by Continental Field Systems                                           Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9"' St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A Items Which Required Repair, Modification, or Replacement Activities Identification Type of Item           Mfg Name   Mfg Serial     Nat'l F H#       I   No Items Installed During Replacement Activities IU   c 1 l_Ldtl                                                                          _tl_
Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9"' St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A Items Which Required Repair, Modification, or Replacement Activities Identification Job Number 3218 Type of Item Mfg Name Mfg Serial Nat'l F H#
Construction Code_ _
I No Items Installed During Replacement Activities Construction Code IU c
Item           Installed/       MFG.       Mfg. Serial       Nat'l Jurisd. No. Other Year Built Name/       Edition/     Code   Code Replaced         Name             No.         Bd. No.                               Section/   Addenda       Case(s) Class Division Poppet           Replaced         WSI             5           N/A       N/A       N/A   2001     I11NB  71 Ed. S71 A     N/A     I Bonnet           Replaced         A&M               3           N/A       N/A       N/A   2001     111 NB 71 Ed. $71 A     N/A     l Pilot Poppet       Replaced         A&M               5           N/A       N/A       N/A   2001     III NB 71 Ed. S71 A     N/A Super Nuts         Replaced         A&M         NU-01017         N/A       N/A       N/A   2002     I11NB  71 Ed. S71 A     N/A     I I of 2
Ldtl 1 l_
_tl_
Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced WSI 5
N/A N/A N/A 2001 I11 NB 71 Ed. S71 A N/A I
Bonnet Replaced A&M 3
N/A N/A N/A 2001 111 NB 71 Ed. $71 A N/A l
Pilot Poppet Replaced A&M 5
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 I11 NB 71 Ed. S71 A N/A I
I of 2 Form NR-1 Attachment


Form NR-1 Attachment                                         Report of Repair / Replacement W orked Performed by Continental Field Systems                                           Job Number 3218 2' Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 "hSt. , Allentown. Penmsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A
Form NR-1 Attachment Report of Repair / Replacement W orked Performed by Continental Field Systems Job Number 3218 2' Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 "h St., Allentown. Penmsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A
: 6. ASME Code Section XI applicable for inservice inspection: 1989                   N/A               N/A (edition)           (addenda)         (Code Case(s))
: 6. ASME Code Section XI applicable for inservice inspection: 1989 N/A N/A (edition)
: 7. ASME Code Section XI used for repairs, modifications, or replacements:1989               N/A               N/A (edition)         (addenda)         (Code Case(s))
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:   1971               Summer 71         1 (edition)         (addenda)         Code Case
(Code Case(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:1989 N/A N/A (edition)
(addenda)
(Code Case(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 Summer 71 1
(edition)
(addenda)
Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A parts, and
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
2 of 2
2 of 2


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production r                                                                                                                                                               Pg. 1of            2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production r
: 1.     Manufactured and certified by                                   Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificate Holder)
Pg. 1 of 2
: 2.     Manufactured for                                             Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address or Purchaser)
: 1.
: 3.     Location of installation                                     PPL Susauehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificate Holder)
: 4.     Type:         A &MDwg D-                 SA 105 Gr.II                       70.0 Ksi                                   N/A                               2001 32467-622 R17                                                                                                                             (year buiLl)
: 2.
(matl. spec. no.)                 (tensile strength)                           (CRN)
Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address or Purchaser)
(drawing no.)
: 3.
S 1971                                  1                            N/A
Location of installation PPL Susauehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
: 5.     ASME Code, Section III, Division 1:                   1971                                                                                         (Code Case no.)
: 4.
(edition)                 (addenda date)                         (class)
Type:
N/A              Revision                  N/A            Date              N/A
A & M Dwg D-SA 105 Gr.II 70.0 Ksi N/A 2001 32467-622 R17 (drawing no.)
: 6.       Fabricated in accordance with Const. Spec. (Div. 2 only)                           (no.)
(matl. spec. no.)
Hardsurfacing. Heat#245951 forSA 105 Gr. II
(tensile strength)
: 7.     Remarks:       21" MSIV Valve Poppet SA 105 Gr.I with SFA 5.13 Alloy 21 Stellite 21 for Stellite 21 "Heat#s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 Dia. ID (ft & in.)    21"Noma      Length overall (ft & in.)     31' N/A           Min. design thickness (in.)       N/A                                                                                       _    _
(CRN)
: 8.       Nom. Thickness (in.)                                                                                               00                                       _
(year buiLl)
for each Item of this report:
: 5.
: 9.       When applicable. Certificate Holder's Data Reports are attached Part or Appurtenance                             National Part or Appurtenance                     National                                                                                     Board No.
ASME Code, Section III, Division 1:
Board No.                                           Seral Number Serial Number                                                                                                                  In Numerical Order In Numerical Order (26)
1971 S 1971 1
(1)   245951-1 (27)
N/A (edition)
(2)   245951-2 (28)
(addenda date)
(3)   245951--4 (29)
(class)
:-    (4)   245951-5 (30)
(Code Case no.)
(5)   245951-7 (31)
: 6.
(6)   245951-8 (32)
Fabricated in accordance with Const. Spec. (Div. 2 only)
(7)   245951-9 (33)
N/A Revision N/A Date N/A (no.)
(8)                                                                                   (34)
: 7.
(9)                                                                                   (35)
Remarks:
(10)                                                                                   (36)
21" MSIV Valve Poppet SA 105 Gr.I with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat#245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21
: 8.
Nom. Thickness (in.)
N/A Min. design thickness (in.)
N/A Dia. ID (ft & in.)
21"Noma Length overall (ft & in.)
31' 00
: 9.
When applicable. Certificate Holder's Data Reports are attached for each Item of this report:
Part or Appurtenance National Part or Appurtenance National Serial Number Board No.
Seral Number Board No.
In Numerical Order In Numerical Order (1) 245951-1 (26)
(2) 245951-2 (27)
(3) 245951--4 (28)
(4) 245951-5 (29)
(5) 245951-7 (30)
(6) 245951-8 (31)
(7) 245951-9 (32)
(8)
(33)
(9)
(34)
(10)
(35)
(36)
(12)
(37)
(37)
(38)
(3 (38)
(12)
(14)  
(3
-- 39 (15)
                                                                                              -- 39 (14)
(15)                                                                                  (41)
(0 (16)
(0 (16)
(41)
(17)
(42)
(42)
(17)
(18)
(43)
(43)
(19)
(44)
(44)
(18)
(20)
(19)
(45)
(45)
(20)                                                                                   (46)
(21)
(21)                                                                                   (47)
(46)
(22)                                                                                  (48)
(22)
(47)
(23)
(23)
(24)                               -(49)
(48)
(24)  
-(49)
(25)
(50)
(50)
(25)
: 10.
N/A           *F       Hydro. test pressure             N/A               at temp. 'F Design pressure                      N/A                    psi      Temp.
Design pressure N/A psi Temp.
10.
N/A  
Design~~~~(we~       prsueNAl            ep                                                                   applicable) x 11, (2) information in items 2 and 3 on this or drawings may be used provided (1) size is 8'A/
*F Hydro. test pressure N/A at temp. 'F Design~~~~(we prsueNA
      - Supplemental information in the form of lists, sketches,                                        sheets is  recorded  at the top of this form.
~
is numbered and the number of Data Report is included orn each sheet, (3) each sheet NJ 07007-2300.
l ep applicable)  
Dept., ASME 22 Law Drive, Box 2300, Fairrield, (12/88)                                   This form (E00040) may be obtained from the Order Reprint (7/91) 1140 )Oct 200 1)W2-31 140. doc 1V.Jbrary~svr~quafly..a Project Files lAtwood & MorriIt20011i3
- Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8'A/ x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/88)
This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairrield, NJ 07007-2300.
Reprint (7/91) 1V.Jbrary~svr~quafly..a Project Files lAtwood & MorriIt20011i3 1140 )Oct 200 1)W2-31 140. doc


FORM N-2 (Back - Page 2 of                           2 Ht # 245951             through       1.2,4.5,7,8,9 Certificate Holder's Serial Nos.
FORM N-2 (Back - Page 2 of 2
CERTIFICATION OF DESIGN CA            Reg. No.J          13655 Boyd P. Brooks                             P.E. State Design Specifications certified by'                        (when applicable)
Certificate Holder's Serial Nos.
MA            Reg. No.            10981 Herbert Cook                                 P.E. State Design Report* certified by                              (when applicable)
Ht # 245951 through 1.2,4.5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by' Boyd P. Brooks P.E. State (when applicable)
CERTIFICATE OF COMPLIANCE 21' MSIV SValve Poppets We certify that the statements made in this report are correct and that this (these) 1.
Design Report* certified by Herbert Cook P.E. State (when applicable)
conform(s) to the rules for construction of the ASME Code, Section III, Division NPT Certificate of Authorization No.       N-2873 x irs        Noe      LO, r 13,2W04 Name      Welding Services Inc.                                SigneC Date       12-10-01                                                                                                                                   - , .&deg;  *
CA Reg. No.J 13655 MA Reg. No.
(NPT Cerlificate Holder)                                       j. ~i       (auhoize reoresentaSIN)
10981 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
NPT Certificate of Authorization No.
N-2873 Date 12-10-01 Name Welding Services Inc.
SigneC (NPT Cerlificate Holder)
: j. ~i (auhoize reoresentaSIN)
CERTIFICATE OF INSPECTION.
CERTIFICATE OF INSPECTION.
of Boiler and Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board and employed by             The Hartford Steam Boiler Inspection and Insurance Co.
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
Georgia                                                                                                                December 10, 2001                and state that to the of     Hartford. CT                     have inspected these items described in this Data Report on parts  or  appurtenances    in  accordance    with  ASME    Code, Section Ill.
of Hartford. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section Ill.
best of my knowledge and belief, the Certificate Holder has fabricated these part listed has been authorized for stamping   on the date shown   above.
Division 1. Each part listed has been authorized for stamping on the date shown above.
J  Division 1. Each any warranty, expressed or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes I
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspecto s employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this inspion.
liable in any manner for any personal injury or property damage or loss in this Data Report. Furthermore, neither the inspecto of any kind arising from or connected wi this inspion.
Comsin NB'
s  employer    shall be
-H
                                                                                                                                                                                  .1
-AAAtN UW Date 122-10-01 Signed Commissions NB # 11465 ABN, GA b
                                                              -AAAtN                         Comsin-H              NB'                      UW Signed                                                     Commissions
3
                                                                                                      *-            NB # 8d.
[Natl. 8d. (incl. Endorsements) and state or proy, and no.]
[Natl.     (incl.ABN, 11465        GA    3 Endorsements)                         b and state or proy, and no.]
%VUibrary svr~quality a Project FiestAtwood & MorrimU2001 31140 )Oct 2001)W2-31140.doc I
Date      122-10-01
J SValve Poppets x irs Noe r 13,2W04 LO,
      %VUibrarysvr~quality aProject FiestAtwood & MorrimU2001 31140 )Oct 2001)W2-31140.doc
,.&deg;
.1


FOR IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA REPORT NUCLEAR PARTS                       AND       APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
III As Required by the Provisions of the ASME Code, Section                                                                 Pg. 1 of 2 Not     to   Exceed         One     Day's       Production
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by               Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 2. Manufactured for           Pennsylvania Power& Light                           Berwick, PA 18603 (name and address of Purchaser)
: 2. Manufactured for Pennsylvania Power& Light Berwick, PA 18603 (name and address of Purchaser)
: 3. Location of installation           Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
SA 105 GR II                          81,600 PSI                            N/A                        2001
: 4. Type:  
: 4. Type:             *32162-409-D Rev. 1                                                                                                     (CRN)                    (year buiM (drawing no.)                       (marl. spec. no.)                   (tensile strength) 1971                            S71                          1                                N/A
*32162-409-D Rev. 1 SA 105 GR II 81,600 PSI N/A 2001 (drawing no.)
: 5. ASME Code, Section III, Division 1:                                                                                       (class)                         (Code Case no.)
(marl. spec. no.)
(idibon)                    (addenda date)
(tensile strength)
N/A              Revision          N/A            Date                  N/A
(CRN)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                               (no.)
(year buiM
: 7. Remarks:           Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA meets the required information of ASME (A&M S.0. 90168) *Dwg. prepared by A&M. This certification Section III 1971 Edition summer 1971 addenda 5.094         Dia. ID (ft & in,)   N/A       Length overall (ft& In.)             N/A
: 5. ASME Code, Section III, Division 1:
: 8. Nom. Thickness (in.)          5.312        Min. design thickness (in.)
1971 S71 1
for each item of this report:
N/A (idibon)
: 9. When applicable, Certificate Holders' Data Reports are attached Part or Appurtenance                          National National                                                                                    Board No.
(addenda date)
Part or Appurtenance                                                                              Serial Number Board No.
(class)
Serial Number                      In Numerical Order                                                                          in Numerical Order N/A                                (26)
(Code Case no.)
(1)    HT: H3391 SIN 1                                                                  (27)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(2)                                                  N/A HT: H3391 SIN 2                                                                  (28)
N/A Revision N/A Date N/A (no.)
P,(3)      HT: H3391 S/N 3 N/A (29)
: 7. Remarks:
(4)                                                                                      (30)
Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.0. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
: 8. Nom. Thickness (in.)
5.312 Min. design thickness (in.)
5.094 Dia. ID (ft & in,)
N/A Length overall (ft& In.)
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
(1)
(2)
P, (3)
(4)
(5)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
-(*3 (14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
Part or Appurtenance Serial Number HT: H3391 SIN 1 HT: H3391 SIN 2 HT: H3391 S/N 3
: 10. Design pressure National Board No.
In Numerical Order N/A N/A N/A Part or Appurtenance Serial Number (26)
(27)
(28)
(29)
(30)
(31)
(31)
(6)
(32)
(32)
(7)                                                                                      (33)
(33)
(8)
(34)
(34)
(9)                                                                                      (35)
(35)
(10)                                                                                      (36)
(36)
(11)                                                                                      (37)
(37) 1381 National Board No.
(12)                                                                                      1381
j4iLiL
        -(*3                                                                            j4iLiL    (39)                                 4.
: 4.
(14)                                                                                      (39)
(39) 1250 psi.
Temp.
(39)
(40)
(40)
(15)                                                                                      (41)
(41)
(16)                                                                                      (42)
(42)
(17)
(43)
(43)
(18)
(44)
(44)
(19)
(45)
(45)
(20)
(46)
(46)
(21)
(47)
(47)
(22)                                                                                      (48)
(48)
(23)
(49)
(49)
(24)                                                                                        (50)
(50) 575
(25) 575            *F. Hydro. test pressure                 N/A             At temp. "F
*F. Hydro. test pressure N/A (whoen applicable)
: 10. Design pressure                  1250            psi. Temp.                                                                      (whoen applicable)
-Supplemental Information in the form of lists, sketches. or drawings may be used provided (1) size is a %x i 1. (2) Information If items 2 and 3 on this Data Report Is Included on each sheet is numbered and the number of sheets is recorded at the top of this form.
    -SupplementalInformation in the form of lists, sketches. or drawings may be used provided (1) size is a%x i 1.(2) Information If items 2 and 3 on this Data Report Is at the top of this form.
(12188)
Included on each sheet is numbered and the number of sheets is recorded 2300, Fairfield, NJ 07D07.2300.       Reprint (7IS1)
This lorm (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07D07.2300.
(12188)                               This lorm (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box
Reprint (7IS1) in Numerical Order At temp. "F


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
HT: H3391 S/N 1               through       S/N 3 Certificate Holders' Serial Nos.
Certificate Holders' Serial Nos.
CERTIFICATION OF DESIGN P.E. State        N/A            Reg. no.                      N/A Design specifications certified by                             N/A (when apphicable)
HT: H3391 S/N 1 through S/N 3 CERTIFICATION OF DESIGN Design specifications certified by N/A (when apphicable)
P.E. State         N/A             Reg. no.                     N/A Design report
Design report
* certified by                              N/A (whfle applicable)
* certified by N/A (whfle applicable)
CERTIFICATE OF COMI and that this (these)                                          Cover We certify that the statements made in this report are correct of the ASME       Code,   Section   III, Division 1.
P.E. State N/A P.E. State N/A Reg. no.
conforms to the rules of construction N2607                            Expires                                6-13-04 NPT Certificate of Authorization No.
N/A Reg. no.
Atwood & Morrill Co., Inc.                       Signed    A2~.~'~
N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
Date                                    Name (NPT Certificate Hold*,)                                             (a tnzedl repro"  tiv)
NPT Certificate of Authorization No.
CERTIFICATE OF INSPECTION of Board of Boiler and Pressure Vessel Inspectors and the State or Province I, the undersigned, holding a valid commission issued by the National S=
Date N2607 Expires Name Atwood & Morrill Co., Inc.
* I L-.                                                U.C*IZIJIL.I      r.n New York                     And employed oy __._._.                                                      ......                        and state that to the of               Hartford, CT                   have inspected these items described in this Data Report on /,                           /       ,
(NPT Certificate Hold*,)
with  the ASME  Code, Section these parts or appurtenances in accordance Best of my knowledge and belief, the Certificate Holder has fabricated                         shown  above.
6-13-04 Signed A2~.~'~
on  the date 1, Division 1. Each part listed has been authorized for stamping                                                                                               described makes any warranty, expressed or implied, conceming the equipment damage or y signing this certificate, neither the inspector nor his employer                                     In any manner for any   personal   Injury or property his employer shall be liable in this Data Report. Furthermore, neither the Inspector nor loss of any kind arising from or connected with this inspect 2              A* AJ Signed         1       *&#xfd;
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed oy of
:XZ                                     L         Commissions         ,AJ .7-,,J Date                                                                                                                          [Narl Bd. (ind. Ea*kmneints) and state or pmv. and no.]
: Hartford, CT have inspected these items described in this Data Report on  
(autx)zaed inmpector
/,  
/
and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section 1, Division 1. Each part listed has been authorized for stamping on the date shown above.
y signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspect Date Signed 1  
*&#xfd;
:XZ L
Commissions  
,AJ 2.7-,,J A* AJ (autx)zaed inmpector
[Narl Bd. (ind. Ea*kmneints) and state or pmv. and no.]
Cover (a tnzedl repro" tiv)
U.C*IZIJIL.I r.n S=
I L-.


IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR             PARTS           AND       APPURTENANCES' III As Required by the Provisions of the ASME Code, Section                                                                         Pg. 1 of 2 Not to Exceed One Day's Production Atwood & Morrill Co., Inc. 285 Canal Street                                       Salem, MA 01970
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by (name and address of NPT C1rtiflcate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT C1rtiflcate Holder)
: 2. Manufactured for           Pennsylvania Power & Light                       Berwick, PA 18603 (name and address of Purchaser)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
: 3. Location of     installation       Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address) 85,700 PSI                                      N/A                        2001
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 4. Type:           *32462-613-C Rev.0                           SA 479-304                                                                           (CRN)                    (yew built)
: 4. Type:  
(marl. spec. no.)                   (tensile strength)
*32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)
(drawing no.)
(marl. spec. no.)
1971                            S71                                    1                              N/A
(tensile strength)
: 5. ASME Code, Section I11,Division 1:                                                                                                 (class)                       (Code Case no.)
(CRN)
(edition)                    (addenda date)
(yew built)
: 6. Fabricated in accordlance with Const, Spec. (Div. 2 only)                             N/A'           Revision                   N/A             Date                 N/A
: 5. ASME Code, Section I11, Division 1:
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121_QLA meets the required information of ASME (A&M S.O. 90168) *Dwg. prepared by A&M. This certification Section I1l 1971 Edition Summer 1971 addenda 1.36          Dia. ID (ft & in.)              N/A    . Length overall (ft& in.)          N/A
1971 S71 1
: 8. Nom. Thickness (in.)           1.50       Min. design thickness (in.)
N/A (edition)
for each Item of this report:
(addenda date)
: 9. When applicable, Certificate Holders' Data Reports are attached National                                      Part or Appurtenance                                    National Board  No.
(class)
Part or Appurtenance                                                                              Serial Number Board No.                                                                                       In Numerical Order Serial Number                        In Numerical Order (26)
(Code Case no.)
N/A (1)      HT:  54682 S/N 1                                                                (27) 54682 S/N 2                            N/A (2)      HT:                                                                            ,(28)
: 6. Fabricated in accordlance with Const, Spec. (Div. 2 only)
N/A (3)    HT:  54682 S/N 3                                                                (29)
N/A' Revision N/A Date N/A
N/A (4)    HT:    54682 S/N 4                                                                (30)
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121_QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section I1l 1971 Edition Summer 1971 addenda
: 8. Nom. Thickness (in.)
1.50 Min. design thickness (in.)
1.36 Dia. ID (ft & in.)
N/A  
. Length overall (ft& in.)
N/A
N/A
: 5)     HT:   54682 S/N 5                                                                (31)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:
N/A (6)     HT:   54682 S/N 6                                                               (32)
Part or Appurtenance Serial Number (1)
N/A (7). HT:   54682 S/N 8                                                               (33)
HT: 54682 S/N 1 (2)
HT: 54682 S/N 9                               N/A (8)                                                                                        (34)
HT: 54682 S/N 2 (3)
(9)                                                                                        (35)
HT: 54682 S/N 3 (4)
(10)                                                                                        (36)
HT: 54682 S/N 4
: 5)
HT: 54682 S/N 5 (6)
HT: 54682 S/N 6 (7).
HT: 54682 S/N 8 (8)
HT: 54682 S/N 9 (9)
(10)
(11)
(11)
(12)
(14)
(15")
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
: 10. Design pressure National Board No.
In Numerical Order N/A N/A N/A N/A N/A N/A N/A N/A 1250 psi.
Temp.
Part or Appurtenance Serial Number (26)
(27)
,(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(37)
(12)
(39)
(39)
(14)                                                                                      (40)
(40)
(15")
(41)
(41)
(16)                                                                                      (42)
(42)
(17)                                                                                        (43)
(43)
(18)                                                                                        (44)
(44)
(19)                                                                                        (45)
(45)
(20)                                                                                        (46)
(46)
(21)                                                                                        (47)
(47)
(22)                                                                                        (48)
(48)
(23)
(49)
(49)
(24)                                                                                      (50)
(50)
(25)
National Board No.
NI/A             At temp. "F C.   (iJUIS,.           r'-
In Numerical Order NI/A At temp. "F C.
: 10. Design pressure                  1250            psi. Temp.                                Vr. Fly 10.       .. F.,   .
(iJUIS,. 
(when applicable) 1i, j21 Information In Items 2 end 3 on this Data Report Is
r'-
    'Supplemental Information in the form of lists, sketches, or drawings may be used provided [1) size Is 8 'A x each sheet Is numbered   and the number of sheets Is recorded   at the top of this form.
Vr. Fly 10.
Included on Box 2300, Fairfield. NJ 07007-2300.      Reprnt (71911 (12188)                               This form (EOOO40) may be obtained from the Order Dept. ASME, 22 Law Drive.
F.,
(when applicable)
'Supplemental Information in the form of lists, sketches, or drawings may be used provided [1) size Is 8 'A x 1i, j21 Information In Items 2 end 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12188)
This form (EOOO40) may be obtained from the Order Dept. ASME, 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300.
Reprnt (71911


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.             HT: 54682 S/N 1               through       S/N 6, 8 & 9 CERTIFICATION OF DESIGN N/A P.E. State        N/A              Reg. no.
Certificate Holders' Serial Nos.
Design specifications certified by                           N/A (when applicable)
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by N/A (when applicable)
P.E. State         N/A             Reg. no.                       N/A Design report
Design report
* certified by                              N/A (when applicable)
* certified by N/A (when applicable)
CERTIFICATE OF COMPLIANCE (these)                                  Pilot Poppet We certify that the statements made in this report are correct and that this rules of construction   of the ASME     Code,   Section   III. Division   1.
P.E. State P.E. State N/A N/A Reg. no.
conforms to the NPT Certificate of Authorization No.                           N2607                             Expires                                 6-13-04          ,t Date                                    Name             Atwood & Morrill Co., Inc.                                                       (audwrttifld  pis  at
N/A Reg. no.
          -4                                                        (NPT Car.ificat Hoalor)
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III. Division 1.
L CERTIFICATE OF INSPECTION of Boiler and'Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board
NPT Certificate of Authorization No.
* 1 90I      e-I.U New York                       And employed by                                                     17. . D. I     ,. U.
Date
and state that to the Hartford, CT                     have inspected   these items   described in this Data Report on               ,*2,,l7 of parts or  appurtenances in  accorddncefwith        the   ASME  Code, Section st of my knowledge and belief, the Certificate Holder has fabricated these has   been   authorized   for stamping     on the date   shown   above.
-4 L
  ,,Division 1. Each part listed any warranty, expressed or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes                                                                                                        or shall be liable in any manner for any personal injury or property damage in this Data Report. Furthermore, neither the inspector nor his employer loss of any kind arising from or connected with this inspection.
Pilot Poppet N2607 Expires Name Atwood & Morrill Co., Inc.
Signed                                                                     Commissions Date                                                                                                                                                                oro pt v. and no]
(NPT Car.ificat Hoalor)
                                                                                                                                -Narl0d. (wmx.Endowsmnerts} and sta
(audwrttifld pis at CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and'Pressure Vessel Inspectors and the State or Province of I. U 1 9 I 0
[,oriz~d
e-New York And employed by
                                      .!-                                     inspector)
: 17.. D. I U.
of Hartford, CT have inspected these items described in this Data Report on  
,*2,,l7 and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accorddncefwith the ASME Code, Section
,,Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date Signed Commissions
[,oriz~d inspector)
-Narl 0d. (wmx. Endowsmnerts} and sta or pt o
: v. and no]
6-13-04
,t


FORM NR-1           REPORT OF REPAIR []                   MODIFICATION ]                       OR REPLACEMENT NI TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
FORM NR-1 REPORT OF REPAIR []
: 1. Work performed by       Continental Field Systems,                             Inc                                           3218 (name of NR certificate holder)                                             (P.O. no., job no., etc.)
MODIFICATION ]
23 Westgate Blvd.                 Savannah,         GA 31405 (address) 2.0wner     PPL       LLC (name) 2 North Ninth Street,                     Allentown,             PA 18101 (address)
OR REPLACEMENT NI TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 3. Name, address and identification of nuclear power plant                     Susquehanna Steam Electric 5 Miles North of Berwick, PA                                             Salem Twp,                 PA 4.System 1-62A                   HIV4!F0 9 9B                          Main Steam
: 1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                             See     Attached Identification                                                       Construction Code                             Activity Type of     Mfg.       Mfg.     Nat'l Bd. Jurisd.     Other       Year         Name!           Edition/       Code         Code         Repair/
(P.O. no., job no., etc.)
No   Item     Name       Serial No. No.       No.                   Built       Section/         Addenda       Case(s)       Class         Mod/
23 Westgate Blvd.
Division                                                     Replace 2
: Savannah, GA 31405 (address) 2.0wner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA Salem Twp, PA 4.System 1-62A HIV4!F0 99B Main Steam
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name!
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
9 10 11 12
9 10 11 12
: 5. b: Items Installed During Replacement Activities                 See Attached Identification                                                                 Construction Code Type of   Installed or. Mfg.       Mfg       Nat'l Bd.       Jurisd     Other         Year       Name/       Edition/         Code         Code Item       Replaced       Name     Serial No.       No.           No                     Built     Section/     Addenda         Case(s)       Class 5a Item No.                                                                                 Division
: 5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.
: 6. ASME Code Section XI applfcable for inservice inspection:               1989                         N/A                               NIA (edition)                     (addenda)                   (Code Cases(s))
Mfg.
: 7. ASME Code Section Xl used for repairs, modifications, or replacements:                   1J89...                 N1 A       -,        -Al     /     -
Mfg Nat'l Bd.
(edition)         (addenda)               (Cod; Caess))
Jurisd Other Year Name/
: 8. Construction Code used for repairs, modifications, or replacements:                       19 71                 S 71]                     N/A (edition)           (addenda)               (Code Cases s))
Edition/
: 9. Design responsibilities:         Atwood & Morrill Co.
Code Code Item Replaced Name Serial No.
: 10. Tests conducted: hydrostatic E] pneumatic ] design pressure [I                         pressureN4A._         psi Code Case(s)
No.
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                           Rev. 8
No Built Section/
: 11. Description of wnrk:          See Attached wueDesrrption SeAt ofyidrk:               ed additional (use of properly identified         sheet(s) or sketch(es) is acceptable)
Addenda Case(s) Class 5a Item No.
: 12. Remarks:_     See Attached Manufacturer's                               Data Report CERTIFICATE OF COMPLIANCE I,     David McCathie                 certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XGof the ASME Code and the National Board Inspection Code "NR" rules.
Division
National Board Certificate of Authorization No.               NR-86                   to use the "NR" stamp expires 5/25,                         2003 NR Certificate Holder       Cont*[ntntal             Fit-ld Slvaopq_ T3i Date 6/18.       2002 Signed                             e)                                         Qualitv         Control Mnnacpr (authorzed representative)                                              (title)
: 6. ASME Code Section XI applfcable for inservice inspection:
CERTIFICATE OF INSPECTION I, a/ i.. iAM F'. Zo 4; CK = holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of 1'7-NA                           tV,4 L            ,1A           and employed by
1989 N/A NIA (edition)
    ",,scfor      u4. EAV,,= uR, kca- C-'-,w, O                                         of 7 H'NS5toN4 9i1                                           have inspected the repair, modification or replacement described in this report on 4 - I                               ZOO               and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codv and the National Board Inspection Code "NR" rules.
(addenda)
(Code Cases(s))
: 7. ASME Code Section Xl used for repairs, modifications, or replacements:
1J89...
N1 A  
-Al /
(edition)
(addenda)
(Cod; Caess))
: 8. Construction Code used for repairs, modifications, or replacements:
19 71 S
71]
N/A (edition)
(addenda)
(Code Cases s))
: 9. Design responsibilities:
Atwood & Morrill Co.
: 10. Tests conducted: hydrostatic E] pneumatic ]
design pressure [I pressureN4A._
psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
 
wueDesrrption ofyidrk:
SeAt ed (use of properly identified additional sheet(s) or sketch(es) is acceptable)
: 12. Remarks:_
See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XG of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-86 to use the "NR" stamp expires 5/25, 2003 NR Certificate Holder Cont*[ntntal Fit-ld Slvaopq_ T3i Date 6/18.
2002 Signed e)
Qualitv Control Mnnacpr CERTIFICATE OF INSPECTION I,
a/ i.. iAM F'. Zo 4; CK =
holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of 1'7-NA L tV,4  
,1A and employed by  
",,sc for u4.
EAV,,= uR, kca-C-'-,w, O
of 7 H'NS5toN4 9i1 have inspected the repair, modification or replacement described in this report on 4 - I ZOO and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codv and the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
Date &H           oZZOOZ. Signed&L f                   ik'r"/.Th?,zS.*A2i"                   CommissionsLJW799OA."*,                             M.
Date &H oZ ZOOZ.
                                                                                                                                                    ,4gZ   4 (inspector) e                       (National Board (incl. endorsements), jurisdiction, and no.)
Signed&L f ik'r"/.Th?,zS.*A2i" CommissionsLJW799OA."*,
M.  
,4gZ 4
(inspector) e (National Board (incl. endorsements), jurisdiction, and no.)
(title)
See Attached wnrk:
: 11. Description of (authorzed representative)


Form NR-1 Attachment                                 Report of Repair / Replacement Worked Performed by Continental Field Systems                                   Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B Items Which Required Repair, Modification, or Replacement Activities Identification Items Installed During Replacement Activities Identification                                                                              Construction Code Item        Installed/    MFG.       Mfg. Serial   Nat'l     Jurisd. No. Other Year Built Name/       Edition/      Code  Code Replaced      Name          No.      Bd. No.                                   Section/    Addenda      Case(s) Class Division Poppet        Replaced      WSI          4        N/A           N/A     N/A    2001      III NB 71 Ed. S71 A             l Bonnet       Replaced     A&M             5       N/A           N/A     N/A     2001     Ill NB 71 Ed. S71 A     N/A     I Pilot Poppet     Replaced     A&M             7       N/A           N/A     N/A     2001     III NB   71 Ed. S71 A     N/A     I Super Nuts      Replaced      A&M       NU-01017     N/A           N/A     N/A     2002     III NB 71 Ed. S71 A     N/A 0                                                                                                                                    o f2
Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B Items Which Required Repair, Modification, or Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Items Installed During Replacement Activities MFG.
Name WSI Mfg. Serial No.
4 Nat'l Bd. No.
N/A Jurisd. No.
N/A Other N/A Year Built 2001 Name/
Section/
Division III NB Construction Code Edition/
Addenda 71 Ed. S71 A Code Case(s)
Bonnet Replaced A&M 5
N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I
Pilot Poppet Replaced A&M 7
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Code Class A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A o f2 Identification Item Poppet Installed/
Replaced Replaced Super Nuts Replaced 0
l


Form NR-1 Attachment                                         Report of Repair / Replacement Worked Performed by Continental Field Systems                                           Job Number 3218
Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems Job Number 3218
(
(
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9t1 St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9t1 St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B
: 6. ASME Code Section Xl applicable for inservice inspection: 1989                   N/A               N/A (edition)           (addenda)         (Code Case(s))
: 6. ASME Code Section Xl applicable for inservice inspection: 1989 N/A N/A (edition)
: 7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989               N/A               N/A (edition)         (addenda)         (Code Case(s))
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:   1971               Summer 71         1 (edition)         (addenda)         Code Case
(Code Case(s))
: 7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989 N/A N/A (edition)
(addenda)
(Code Case(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 Summer 71 1
(edition)
(addenda)
Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Sreplace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Sreplace with new components from OEM as part of valve enhancement.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
2 of 2
2 of 2


REPORT FOR IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
Code, Section III As Required by the Provisions of the ASME Not to Exceed One Day's Production                                                                         Pg.l1of           2 Norcross GA 30071 Welding Services, Inc. 2225 Skyland Court, Holder)
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg.l1of 2
Manufactured and certified by                                                          (name and address       of NPT   Certificate MA 01970 Atwood & Morril Co. 285 Canal Street. Salem,
Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA 30071 (name and address of NPT Certificate Holder)
: 2. Manufactured for                                                                      (name and address of Purchaser)
: 2.
PPL Susquehanna Nuclear               Power     Plant. Berwick, PA. 18603 and address)
Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
( n*TKam
: 3.
: 3. Location of installation N/A                               2001 bl)
Location of installation PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603
SA 105 Gr.11                       70.0 Ksi
( n*TKam and address)
: 4.      Type:        32467-622   D-A&MDw R17(RN(y (CRN)                           (year buill)
: 4.
(matl. spec. no.)                 (tensile slrenglh)
Type:
(drawing no.)                                                                                                                                     N/A S 1971                                  1 1971
A&MDw D-SA 105 Gr.11 70.0 Ksi N/A 2001 32467-622 R17(RN(y bl)
: 5.     ASME Code, Section III, Division 1:                                                 (addenda dale)                            (class)                      (Code Case no.)
(drawing no.)
(matl. spec. no.)
(tensile slrenglh)
(CRN)
(year buill)
: 5.
ASME Code, Section III, Division 1:
1971 S 1971 1
N/A
("dilion)
("dilion)
N/A              Date            N/A (Div. 2 only)             N/A                Revision
(addenda dale)
: 6. Fabricated in accordance with Const. Spec.                                             (no.)
(class)
5 for SA 105 Gr. II 1
(Code Case no.)
Alloy 21 Stellite 21 Hardsurfacing. Heat# 2459
: 6.
: 7.     Remarks:         21     MSIV Valve poppet SA 105 Gr.ll with SFA 5.13 21 01-0876 and 1210-NO832R125 for Stellite "Heat#s   00-21-01, 00_21-05,00-21-06,101001836, 21'Nom.       Length overall (Ift in.)       31 NIA                 Dia. ID (ft & in.)
Fabricated in accordance with Const. Spec. (Div. 2 only)
Nom. Thickness (in.)          N/A            Min. design thickness (in.)
N/A Revision N/A Date N/A (no.)
8, report:
: 7.
Reports are attached for each item of this
Remarks:
: 9. When applicable, Certificate Holder's Data Part or Appurtenance                             National Part or Appurtenance                           National                                                                                         Board No.
21 MSIV Valve poppet SA 105 Gr.ll with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 2459 5 1 for SA 105 Gr. II "Heat #s 00-21-01, 00_21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21 8,
Serial Number Serial Number                            Board No.                                                                                   In Numerical Order
Nom. Thickness (in.)
(                                                              In Numerical Order (26)
N/A Min. design thickness (in.)
(1)   245951-1                                                                           (27)
NIA Dia. ID (ft & in.)
(2)   245951-2 (28)
21'Nom.
    --.J13) 245951-4                                                                                 (29)
Length overall (Ift in.)
(4) 245951-5                                                                               (30)
31
(5)   245951-7                                                                             (31)
: 9.
(6)   245951-8                                                                             (32)
When applicable, Certificate Holder's Data Reports are attached for each item of this report:
(7)   245951-9 (33)
Part or Appurtenance National Part or Appurtenance National Serial Number Board No.
(8)                                                                                       (34)
Serial Number Board No.
(9)                                                                                       (35)
(
In Numerical Order In Numerical Order (1) 245951-1 (26)
(2) 245951-2 (27)  
--.J13) 245951-4 (28)
(4) 245951-5 (29)
(5) 245951-7 (30)
(6) 245951-8 (31)
(7) 245951-9 (32)
(8)
(33)
(9)
(34)
(10)
(10)
(11)       .                                                                                (36)
(35)
(11)
(36)
(12)
(37)
(37)
(12)                                                                                         (38)                       _________
(38)
                                "                                                                      (40)
(14)
(14)                                                                                         (40)
(40)
(15)                                                                                         (41)
(15)
(16)                                                                                         (42)
(40)
(17)                                                                                         (43)
(16)
(18)                       --.------
(41)
(19)                                                                                         (44)
(17)
(42)
(18)
(43)
(19)
(44)
(20)
(45)
(45)
(20)                                                                                         (46)
(21)
(21)                                                                                         (47)
(46)
(22)                                                                                         (8 (23)                                                                                         (49)
(22)
(24)                                                                                        (50)
(47)
(23)
(8 (24)
(49)
(25)
(25)
N/A              at temp. 'F
(50)
: 10. Design pressure NIA                     psi. Temp.
: 10.
(______(when NIA             F     Hydro. test pressure applicable) in items 2 and 3 on this (1) size is 8'A x 11, (2) information in the form of lists, sketches,    or drawings may be used provided                              the top of this form.
Design pressure NIA psi.
        'Supplemental information                                                                number of sheets is recorded at (3) each sheet is numbered and the Data Report is included orn each sheet, Drive, Box 2300, Fairfield, NJ 07007-2300.
Temp.
from the Order Dept., ASME 22 Law                                                Reprint (7191)
NIA F
This form (EO0040) may be obtained (12/88) 0
Hydro. test pressure N/A at temp. 'F
                                                              & MornhI20 1131U"40 )Oct 2001)W2-31140.doc 1\UJbrary_svr(quafiy_a fProject FilesoAtwood
(______(when applicable)  
'Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8'A x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/88)
This form (EO0040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
Reprint (7191) 1\\UJbrary_svr(quafiy_ a fProject FilesoAtwood & MornhI20 0 1131U"40 )Oct 2001)W2-31140.doc


FORM N-2 (Back - Page 2 of                               2   )
FORM N-2 (Back - Page 2 of 2 )
Ht # 245951                 through       1,2,4,5,7,8,9 Certificate Holder's Serial Nos.
Certificate Holder's Serial Nos.
CERTIFICATE OF COMPLIANCE and that this (these)                 21' MSIV Valve Poppets We certify that the statements made in this report are correct Section III, Division 1.
Ht # 245951 through 1,2,4,5,7,8,9 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
conform(s) to the rules for construction of the ASME Code,                                                               x ires        Nove      r 13, 2004 NPT Certificate or Authorization No.       N-2873 Welding Services Inc.                                         Sign             ,.                    Lui.-
NPT Certificate or Authorization No.
o k Date        12-10-01              Name                                                                                                                  representative (NPT Certificate Holder)authorized CERTIFICATE OF INSPECTION.                                                                                         "
N-2873 x ires Nove r 13, 2004 Date 12-10-01 Name Welding Services Inc.
and the State or Province  of Board of Boiler and Pressure Vessel Inspectors 1,the undersigned, holding a valid commission issued by theandNational  employed by             The Hartford Steam Boiler Inspection and Insurance Co.
Sign Lui.-
Georgia                                                                                                                        December 10, 2001                    and state that to the of       Hartford,. CT                   have inspected these items described in this Data Report on these parts or appurtenances           in   accordance   with ASME     Code, Section III, best of my knowledge and belief, the Certificate Holder has fabricated                shown    above.
o k (NPT Certificate Holder)authorized representative CERTIFICATE OF INSPECTION.
for stamping    on  the  date "livision 1. Each part listed has been authorized
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
                                                    ""..    .  . ... r Nhis ernnlnver makes         any warranty. expressed or Implied, concerning the equipment described damage or loss mployer- shall be liable in any manner for any personal injury or property By signing this certinlc te, neither th   ns,.,.p   ,,v,..       .. -,z   . ....            *.
of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section III, "livision 1. Each part listed has been authorized for stamping on the date shown above.
in this Data Report. Furthermore, neither the insp                       hi of any kind arising from or connected wi this insp ion.                               ______
.... r Nhis ernnlnver makes any warranty. expressed or Implied, concerning the equipment described By signing this certinlc te, neither th ns,.,.p  
r%f.         12-10-0l1         Signed                                                             Commissions       NB #11465 ABN. GAW 393                                 edn
,,v,..  
                                                                                                ,...   "          I~~~Natl.Bd. (incl.l E:ndorsements) arm state, or ro-.-,   ..
-,z in this Data Report. Furthermore, neither the insp hi mployer-shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this insp ion.
                                                                                )Oct 2001)W2-31140.doc
r% f.
    \jbrary.svrlquaity.aProject Flies lAtwood & MorriMll200131140
12-10-0l1 Signed Commissions NB #11465 ABN.
GAW 393 edn
\\jbrary.svrlquaity.a Project Flies lAtwood & MorriMll200 131140 )Oct 2001)W2-31140.doc I~~~Natl.
Bd. (incl.l E:ndorsements) arm state, or ro-.-,  


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III                                                             Pg. 1 of 2 Not to Exceed One Day's Production
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by               Atwood & Morrill Co., Inc. 285 Canal Street                                   Salem, MA 01970 (name and addresS of NPT CerUtflcat Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and addresS of NPT CerUtflcat Holder)
: 2. Manufactured for         Pennsylvania Power & Light                           Berwick, PA 18603 (name and address of Purchaser)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
: 3. Location of installation           Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
SA 105 GR II                         77,900 . .. ... PSI N/A
: 4. Type:
                                                                                                                                          ~~~~1                           2001
*32162-409-D Rev. 1 SA 105 GR II 77,900 PSI N/A 2001
: 4. Type:            *32162-409-D Rev. 1                                                                                .,t-t                                             y ar W inl (draw.ng no.)                         (Marl. Spec. no.)                 (tensile      ength)                  %-1 a 0"'1                       .q71 N/A 1
~~~~1  
: 5. ASME Code, Section III, Division 1:                            II=                          *-'
.,t-t y ar W inl (draw.ng no.)
                                                                "(edibon)                 (addenda date)                       (Class)                   t a       .  ,,a.,9 N/A              Revision              N/A          Date                  N/A
: 5. ASME Code, Section III, Division 1:
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                             (no.)
(Marl. Spec. no.)
: 7. Remarks:           Gust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA information of ASME (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required Section III 1971 Edition summer 1971 addenda Min. design thickness (in.)             5.094         Dia. ID (ft & in.)         N/A     Length overall (rt& in.)             N/A
a 0"'1 (tensile ength)
: 8. Nom. Thickness (in.)          5.312 item of this report:
.q71 1
: 9. When applicable, Certificate Holders' Data Reports are attached for each Part or Appurtenance                           National Part or Appurtenance                           National Serial Number                           Board No.
N/A
Serial Number                             Board No:
"(edibon)
In Numerical Order In Numerical Order NJA                              (26)
(addenda date)
(1)    HT: H3391 S/N 4                                                                 (27)                                                                              I
(Class) t a 9
      ,-(2)      HT: H3391 S/N 5                               N/A (28)
,,a.,
(3)    HT: H3391 S/N 6                               N/A                               (29)
Fabricated in accordance with Const. Spec. (Div. 2 only)
(4)                                                                                   (30)
N/A Revision N/A Date N/A (no.)
(5)                                                                                     (31)
Remarks:
(6)                                                                                     (32)
Gust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda Nom. Thickness (in.)
(7)                                                                                    (33)
5.312 Min. design thickness (in.)
(8)                                                                                    (34)
5.094 Dia. ID (ft & in.)
(9)                                                                                  .(35)
N/A Length overall (rt& in.)
(10)                                                                                    (36)
N/A When applicable, Certificate Holders' Data Reports are attached for each item of this report:
(11)                                                                                      (37)
Part or Appurtenance National Part or Appurtenance National Serial Number Board No:
(12)                                                                                      (38)
Serial Number Board No.
In Numerical Order In Numerical Order HT: H3391 S/N 4 NJA HT: H3391 S/N 5 N/A HT: H3391 S/N 6 N/A (26)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)  
.(35)
(36)
(37)
(38)
(39)
(39)
(14)                                                                                     (40)
(40)
(15)                                                                                     (41)
(41)
(16)                                                                                     (42)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
: 10. Design pressure 1250 psi.
Temp.
575
'F. Hydro. test pressure
"-Supplemental Information In the form of lists, sketches, or drawings may be used provided (I) size is B 'V x 11, 12) Information In items 2 and 3 on this Data Report is included an each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12)88)
This lorm (E00040) may be obtained from the Order Dept., ASME. 22 Low Drive. Box 2300, Fairfield. NJ 07007-2300.
Reprint (7191)
: 6.
: 7.
: 8.
9.
(1)
,-(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(14)
(15)
(16)
(17)
(17)
(18)                                                                                      (43)
(18)
(19)                                                                                      (44)
(19)
                      --  -----                                                                    (45)
(20)
(20)
(46)
(21)
(21)
(47)
(22)
(22)                                                                                    (48)
(23)
(23)
(49)
(24)
(24)
(50)
(25)
(25)
                                                                                                    'F. Hydro. test pressure                    N/A               At temp. F
N/A (when applicable)
: 10. Design pressure                  1250            psi. Temp.              575                                                  (when applicable)
At temp. F II =
In items 2 and 3 on this Data  Report is
I
  "-Supplemental Information In the form of lists, sketches, or drawings may be used provided (I) size is B 'V x 11, 12) Information included an each sheet Is numbered and    the number of sheets is recorded at the top of this form.
-1
Reprint (7191)
(12)88)                              This lorm (E00040) may be obtained from the Order Dept., ASME. 22 Low Drive. Box 2300, Fairfield. NJ 07007-2300.


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.       HT: H3391         SIN 4           through           S/N 6 CERTIFICATION OF DESIGN N/A                          P.E, State      N/A            Reg. no.                          N/A Design specifications certified by (when applicable)
Certificate Holders' Serial Nos.
N/A                               P.E. State       N/A           Reg. no.                           N/A Design report
HT: H3391 SIN 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by Design report
* certified by 1when applicable)
* certified by N/A (when applicable)
CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these)                                           Cover conforms to the rules of construction of the ASME Code, Section III, Division 1.
N/A 1when applicable)
NPT Certificate of Authorization No.                       N2607                         Expires                              6-13-04_              ,,,.
P.E, State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
Signed  -      -r Date                                    Name          Atwood & Morrill Co., Inc.
NPT Certificate of Authorization No.
(NPT Certficate Hold"er                         S(a=lonzed                 foprosonitat.ne)
N2607 Reg. no.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Npew York                    And employed by                                               H.S.B.I & I. Co.           ,
Reg. no.
Hartford, CT                 have inspected these items described in this Data Report on           Z,.,,/,,$'                 , and state that to the
Cover Expires Atwood & Morrill Co., Inc.
  -st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord'ance'with the ASME Code, Section il, Division 1. Each part listed has been authorized for stamping on the date shown above.
(NPT Certficate Hold"er Signed
described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment or in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage loss of any kind arising from or connected with this inspection.
-r S(a=lonzed foprosonitat.ne)
Date         ,V                 Signed   ___                                            _Commissions               ,.V>'r7e,                   .,,q J
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.
            "//I                                            (authorized inspector)                             [Narl 8d. (incl, Endorsernetil'J and s;tate or prey. and: no.I
Hartford, CT have inspected these items described in this Data Report on Z,.,,/,,$'  
, and state that to the  
-st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord'ance'with the ASME Code, Section il, Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date  
,V Signed
_Commissions  
,.V>'r7e,  
.,,q J N/A N/A Date Name Npew York 6-13-04_
(authorized inspector)
"//I
[Narl 8d. (incl, Endorsernetil'J and s;tate or prey. and: no.I


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                   Pc. 1 of.2 Pg. 1 of .2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
'. Manufactured and certified by               Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 4fidmt aIiU aDorn. vi flrl tCitiflCIt* rroiosr i
'. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 4fidmt aIiU aDorn. vi flrl tCitiflCIt* rroiosr
2name and aturess ofeNfe    PAertfcate 1l860er)
2name and aturess ofe Nfe i
: 2. Manufactured for         Pennsylvania Power & Light                         Berwick, PA 18603 nam..nu.our.ssoi         rurcnaser, Stre aeress 3name        A         ntwnPaser) fe
PAertfcate 1l860er)
: 3. Location of installation         Susquehanna 11 2 North Ninth Street Allentown, PA 18101-1179 (name and eaddress)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603
: 4. Type:           "32462-613-C Rev.0                         SA 479-304                         85.7008570PIN/A PSI                           N/A 2002fl rawnrg no.)                        (marl. spec. no.)                (tensile strength)                        (CRN)                      (year built)
nam..nu.our.ssoi rurcnaser, 3name Stre aeress A
: 5. ASME Code, Section III,Division 1:
fe ntwnPaser)
1971                          S71                              1                                N/A jaooenoa oate)                        1 (class)
: 3. Location of installation Susquehanna 11 2 North Ninth Street Allentown, PA 18101-1179 (name and eaddress)
N/A (Code Case no.)
: 4. Type:
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                                         Revision                              Date N/A                                   N/A                                     N/A (no.)
"32462-613-C Rev.0 SA 479-304 85.700 PSI 8570PIN/A 2002fl rawnrg no.)
: 7. Remarks:           Cust. Item 01 A&M Item 11 Qty. 1 Pilot Poppet A&M P/N 32462-613-4226-121_QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addend*
: 5. ASME Code, Section III, Division 1:
: 8. Nom. Thickness (in.)           1.50       Min. design thickness (in.)           1.36         Dia. ID (ft & in.)       N/A         Length overall (ft& in.)             N/A
(marl. spec. no.)
1971
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(tensile strength)
S71 jaooenoa oate)
N/A (no.)
Revision (CRN) 1 N/A (class)
N/A (year built)
(Code Case no.)
Date N/A
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 1 Pilot Poppet A&M P/N 32462-613-4226-121_QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addend*
: 8. Nom. Thickness (in.)
1.50 Min. design thickness (in.)
1.36 Dia. ID (ft & in.)
N/A Length overall (ft& in.)
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
Part or Appurtenance                           National                                Part or Appurtenance                                National Serial Number                             Board No.                                    Serial Number                                  Board No.
Part or Appurtenance Serial Number HT: 54682 S/N 7 National Board No.
In Numerical Order                                                                           In Numerical Order
In Numerical Order N/A 4.
      .(1)      HT: 54682 S/N 7                              N/A                             (26)
4-4.
(2)                                                                                  (27) 4.
Part or Appurtenance Serial Number (26)
(3)                                                                                  (28)                                     +
(27)
4-(4)                                                                                  (29)                                     4-4.
(28)
(5)                                                                                  (30)                                     +
(29)
(6)                                                                                  (31)                                     4-(7)                                                                                  (32)
(30)
(8)                                                                                (33)                                     .4.
(31)
(9)                                                                                (34)                                     .4.
(32)
(10)                                                                                  (35)                                     +
(33)
(11)                                                                                                                            .4.
(34)
(35)
(36)
(36)
(12)                                                                                  (37)                                     -I.
(37)
(13)                                                                                  (38)                                     +
(38)
(14)                                                                                                                            4.
(39)
(39)
(15)                                                                                  (40)
(40)
(16)                                                                                  (41)                                     +
(41)
(17)                                                                                  (42)                                     4-(18)                                                                                  (43)                                     1-(19)                                                                                                                          -4.
(42)
(43)
(44)
(44)
                                                                                                                                      .4.
(4S)
(20)                                                                                  (4S)
(46)
(21)                                                                                  (46)                                     1-(22)                                                                                  (47)                                     4.
(47)
I (23)                                                                                  (48)
(48)
(24)                                                                                  (49)
(49)
(25)                                                                                  (50)
(50)
    ). Design pressure               1250             psi. Temp.                                                                                               At temp. "F 575         'F. Hydro. test pressure                       N/A (w'hen epplicable)
National Board No.
"Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size Is 8 'A x 11, (2) information In Items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
In Numerical Order
(121`11)                            This form (E0O0040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
+
4-
+
4-
.4.
.4.
+
.4.
-I.
+
4.
+
4-1-
-4.
.4.
1-4.
I
). Design pressure 1250 psi.
Temp.
575  
'F.
Hydro. test pressure "Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size Is 8 'A x 11, (2) information In Items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
This form (E0O0040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
.(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
N/A (w'hen epplicable)
At temp. "F Pg. 1 of.2 Pc. 1 of.2 N/A 1
N/A (121`11)


Reprint (71 91)
Reprint (71 91)
FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.         HT: 54682 S/N 7           through       N/A CERTIFICATION OF DESIGN Design specifications certified by                           N/A                            P.E. State      N/A        Reg. no.                          N/A (wh~enapplicable)
Certificate Holders' Serial Nos.
Design report
HT: 54682 S/N 7 through N/A CERTIFICATION OF DESIGN Design specifications certified by Design report
* certified by                            N/A                                 P.E. State     N/A       Reg. no.                           N/A (when applicable)
* certified by N/A (wh~en applicable)
CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
N/A (when applicable)
P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
Pilot Poppet NPT Certificate of Authorization No.
Pilot Poppet NPT Certificate of Authorization No.
N2607                           Expires                           6-13-04 Date                                      Name           Atwood & Morrill Co., Inc.                     Signed (NPT Certificate Holder)                                       (aufo~hzed-representative)
Date N2607 Expires Name Atwood & Morrill Co., Inc.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York                      And employed by                                                   HSBCT of                 Hartford, CT                 have inspected these items described in this Data Report on                   i               , and state that to the 11'st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in acco(dande with the ASME Code, Section
(NPT Certificate Holder) 6-13-04 Signed (aufo~hzed-representative)
        )ivision 1. Each part listed has been authorized for stamping on the date shown above.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by HSBCT of Hartford, CT have inspected these items described in this Data Report on i  
, and state that to the 11'st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in acco(dande with the ASME Code, Section  
)ivision 1. Each part listed has been authorized for stamping on the date shown above.
signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date               1             Signed7..-.                                                           C    s Commissions                 70..
Date 1
En-oran"
C s
[NatI lad. (incl. Endorsennents) A~d stte or.
Signed7..-.
w or prov. and no.)
Commissions 70..
En-oran" w or.
[NatI lad. (incl. Endorsennents) A~d stte or prov. and no.)
Reg. no.
Reg. no.
N/A N/A New York


FORM NR-1           REPORT OF REPAIR [k                   MODIFICATION L]                   OR REPLACEMENT                 [X]
FORM NR-1 REPORT OF REPAIR [k MODIFICATION L]
OR REPLACEMENT [X]
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 1. Work performed by         Continental Field Systems,                             Inc                               3218 (name of NR certificate holder)                                           (P.O. no., job no., etc.)
: 1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
23 Westgate Blvd.                 Savannah.           GA 31405 (address)
(P.O. no., job no., etc.)
: 2. Owner           PPL     LLC (name) 2 North Ninth Street,                     Allentown,               PA 18101 (address)
23 Westgate Blvd.
: 3. Name, address and identification of nuclear power plant                 Susquehanna Steam Electric 5 Milp* North of Rprwirt-k, PA                                             Ralem Twp, PA 4.System 1-62A                 HV141FO22C                                   MainSteam
Savannah.
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                               See Attached Identification                                                       Construction Code                             Activity Type of     Mfg.       Mfg.     Nat'l Bd. Jurisd.       Other       Year       Name/           Edition/         Code         Code         Repair/
GA 31405 (address)
No     Item       Name     Serial No. No.       No.                   Built     Section/       Addenda         Case(s)       Class         Mod/
: 2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
Division                                                   Replace 2
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Milp* North of Rprwirt-k, PA Ralem Twp, PA 4.System 1-62A HV141FO22C MainSteam
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
9 10 11 12
9 10 11 12
: 5. b: Items Installed During Replacement Activities               See Attached Identification                                                               Construction Code Type of   Installed or. M~fg.       Mfg         Nat'l Bd. Jurisd Other                 Year       Name/         Edition/         Code       Code Item       Replaced     Name Serial No.             No.             No                 Built     Section/     Addenda         Case(s) Class 5a Item No.                                                                                 Division
: 5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.
M~fg.
Mfg Nat'l Bd.
Jurisd Other Year Name/
Edition/
Code Code Item Replaced Name Serial No.
No.
No Built Section/
Addenda Case(s) Class 5a Item No.
Division
: 6. ASME Code Section XI applfcable for inservice inspection:
: 6. ASME Code Section XI applfcable for inservice inspection:
19.8 9 N/A I _____
19.8 9 N/A N/A (edition)
N/A (edition)                   (addenda)                   (Code Cases(s))
(addenda)
: 7. ASME Code Section XGused for repairs, modifications, or replacements:                       1o9               N/A                         N/A (ediion)         (addenda)               (Code Cases(s))
(Code Cases(s))
rl           8. Construction Code used for repairs, modifications, or replacements:                         19g 71               S-71]                   N/A (edition)           (addenda)               (Code Cases(s))
: 7. ASME Code Section XG used for repairs, modifications, or replacements:
: 9. Design responsibilities:     Atwood & Morrill Co.
1o9 N/A N/A (ediion)
: 10. Tests conducted: hydrostatic E]       pneumatic El         design pressure []         pressureN/.L           psi Code Case(s)
(addenda)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                         Rev. 8
(Code Cases(s))
rl
: 8. Construction Code used for repairs, modifications, or replacements:
19g 71 S-71]
N/A (edition)
(addenda)
(Code Cases(s))
: 9. Design responsibilities:
Atwood & Morrill Co.
: 10. Tests conducted: hydrostatic E] pneumatic El design pressure []
pressureN/.L psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
_____ I


I--
I--
11 Descrrintinnofwnrk:       See Attarpchl (use of properly identified additional sheet(s) or sketch(es) is acceptable)
11 Descrrintinnofwnrk:
: 12. Remarks:           See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I, David McCathie                     certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
See Attarpchl (use of properly identified additional sheet(s) or sketch(es) is acceptable)
National Board Certificate of Authorization No.                 NR-8 6                   to use the "NR" stamp expires                     255    2003 NR Certificate Holder     _  an /--t             I FIM1           RXr             T-. nc Date 6Qsrfy                                                                                                             Cnt--l           M/1a2r0 (authorized representative)                                                 (ttle)
: 12. Remarks:
CERTIFICATE OF INSPECTION I, W(It-Y"AAi'* - ?6O6{'     77.     holding a valid commission issued bjyThe National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of b"A'YNIY. YVAV/,4                                             and employed by
See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I, David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
  &7bThY M       rUuA     -LAJSLJRAA,rLcC/;               m~                             -of     U0T     MSH AIb lS         X               _    have inspected the repair, modification or replacement described in this report on A4tI..                                 0-,         .. and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-8 6 to use the "NR" stamp expires 25 5
2003 NR Certificate Holder an /--t I FIM1 RXr T-. nc Date 6Qsrfy Cnt--l M/1a2r0 (authorized representative)
(ttle)
CERTIFICATE OF INSPECTION I, W(It-Y"AAi'*  
?6O6{'
: 77.
holding a valid commission issued bjy The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of b"A'YNIY. YVAV/,4 and employed by  
&7bThY M
rUuA  
-L AJSLJRAA,rLcC/;
m~  
-of U0T MSH A
lS Ib X
have inspected the repair, modification or replacement described in this report on A4tI..
0-,
and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
Date(yWc) 2Z           OO       Signed   6idao.1)?                                           ComriissiiosM?
Date(yWc) 2Z OO ti2 Signed 6idao.1)?
ti2                    O4&r8,WS             PAZn O+
ComriissiiosM?
(inspector),//                       (National Board (icl-endorsements), jarisciction,and no.)
O4&r8,WS PAZn O+
(inspector),//
(National Board (icl-endorsements), jarisciction, and no.)


Form NR-1 Attachment                                              Report of Repair / Replacement Worked Performed by Continental Field Systems                                                   Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C Items Which Required Repair, Modification, or Replacement Activities Identification                                                                                                         Construction Code No       Type of Item         Mfg. Name   Mfg. Serial     Nat'l Bd. Jurisdiction     Other     Year     Name/ Section/     Edition /       Code     Code Class     Repair/
Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C Items Which Required Repair, Modification, or Replacement Activities Identification Job Number 3218 Construction Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.
                                                #            No.             No.                     Built       Division       Addenda         Case(s)                 Replace I         MSIV               A&M         3-221         N/A             N/A           N/A       1974     ASME lII/NB       1971/S71       1535-2       I         Repair 2
Jurisdiction Other Year Name/ Section/
Items Installed During Replacement Activities Identification                                                                                                         Construction Code Item           Installed/     MFG.       Mfg. Serial         Nat'l       Jurisd. No. Other     Year Built     Name/           Edition/     Code       Code Replaced       Name             No.           Bd. No.                                               Section/         Addenda     Case(s)     Class Division Poppet         Replaced         WSI             8             N/A             N/A         N/A       2001         III NB       71 Ed. S71 A   N/A           I Bonnet         Replaced       A&M               8             N/A             N/A         N/A       2001         Ill NB       71 Ed. S71 A   N/A           I Pilot Poppet       Replaced       A&M               8             N/A             N/A         N/A       2001         III NB       71 Ed. 871 A   N/A           I Super Nuts       Replaced       A&M         NU-01017           N/A             N/A         N/A       2002         III NB       71 Ed. S71 A   N/A           I f2
Edition /
Code Code Class Repair/
No.
No.
Built Division Addenda Case(s)
Replace I
MSIV A&M 3-221 N/A N/A N/A 1974 ASME lII/NB 1971/S71 1535-2 I
Repair 2
Items Installed During Replacement Activities Identification Construction Code Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced WSI 8
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Bonnet Replaced A&M 8
N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I
Pilot Poppet Replaced A&M 8
N/A N/A N/A 2001 III NB 71 Ed. 871 A N/A I
Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I
f2 Form NR-1 Attachment


Form NR-1 Attachment                                         Report of Repair / Replacement Worked Performed by Continental Field Systems                                           Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C
Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Report of Repair / Replacement Job Number 3218 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C
: 6. ASME Code Section XI applicable for inservice inspection: 1989                   N/A             NI A (edition)           (addenda)       (C ode Case(s))
: 6. ASME Code Section XI applicable for inservice inspection: 1989 N/A NI (edition)
: 7. ASME Code Section XI used for repairs, modifications, or replacements:]1989             N/A              N/A (edition)         (addenda)        (Code Case(s))
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:   1971             Summer 71         I (edition)         (addenda)         Code Case
(C
: 7. ASME Code Section XI used for repairs, modifications, or replacements:]1989 N/A (edition)
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:
1971 Summer 71 (edition)
(addenda)
A ode Case(s))
N/A (Code Case(s))
I Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A 1I. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and C replace with new components from OEM as part of valve enhancement.
: 10. Test Conducted N/A 1I. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and C
replace with new components from OEM as part of valve enhancement.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
2 of 2
2 of 2


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                 Pg. I of           2
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of 2
: 1. Manufactured and certified by                                 Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificale Holder)
: 1.
: 2. Manufactured for                                           Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser) 18603
: 2.
: 3. Location of installation                                     PPL Susquehanna Nuclear Power Plant. Berwick, PA.
: 3.
(name and address)
: 4.
Type:       A&MDwg       -            SA 10 Gr.fl                       70.0 Ksi                                 N/A                               2001 4.
: 5.
32467-622 Rf7                                                                                       (CRN)                            (year built)
: 6.
(drawing no.)           (mail. spec. no.)               (tensile strength)
7.
ASME Code,       Section III, Division 1:           1971                         S 1971                             1                               N/A
: 10.
: 5.                                                                                    (addenda date)                     (class)                     (Code Case no.)
Design pressure NIA psi.
(edition)
Temp.
N/A              Revision                N/A              Date            N/A
NIA
: 6. Fabricated'in accordance with Const. Spec. (Div. 2 only)                         (no.)
*F Hydro. test pressure N/A at temp. F (when applicable)
Hardsurfacing. Heat# 245951 forSA 105 Gr. II
* Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8%A x 11, (2) information in items 2 and 3 on this Data Report is included ori each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 7. Remarks:       21" MSIV Valve Poppet SA 105 Gr.Il with SFA 5.13Alloy21 Stellite2l 1210-NO832R125 for Stellite 21 "Heat#s   00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and Dia. ID (ft & in.)    21 No.       Length overall (ft & in.)     31' NIA       Min. design thickness (in.)       N/A                                   0o
(12/88)
: 8. Nom. Thickness (in.)
This form (EO0040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 Reprint (7/91:
each Item of this report:
V~jbrary svrquafit~y aProject FiestAtwood & Mornlr200 1U31140 )Oct 200 1)W2-31140.doc Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificale Holder)
: 9. When applicable, Certificate Holder's Data Reports are attached for Part or Appurtenance                           National Part or Appurtenance                     National                                                                                 Board No.
Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
Board No.                                         Serial Number Serial Number                                                                                                              In Numerical Order In Numerical Order N/A              at temp. F psi. Temp.          NIA          *F      Hydro. test pressure
Location of installation PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
: 10. Design pressure                    NIA                                                                                              (when applicable) x 11, (2) information in items 2 and 3 on this or drawings may be used provided (1) size is 8%A
Type:
    *Supplemental information in the form of lists, sketches,                                                            the top of this form.
A&MDwg SA 10 Gr.fl 70.0 Ksi N/A 2001 32467-622 Rf7 (drawing no.)
is numbered and the number of sheets is recorded at Data Report is included ori each sheet, (3) each sheet 07007-2300 Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ Reprint (7/91:
(mail. spec. no.)
(12/88)                                  This form (EO0040) may be obtained from the Order 1U31140 )Oct 200 1)W2-31140.doc V~jbrary svrquafit~y aProjectFiestAtwood & Mornlr200
(tensile strength)
(CRN)
(year built)
ASME Code, Section III, Division 1:
1971 S 1971 1
N/A (edition)
(addenda date)
(class)
(Code Case no.)
Fabricated'in accordance with Const. Spec. (Div. 2 only)
N/A Revision N/A Date N/A (no.)
Remarks:
21" MSIV Valve Poppet SA 105 Gr.Il with SFA 5.13Alloy21 Stellite2l Hardsurfacing. Heat# 245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21 Nom. Thickness (in.)
NIA Min. design thickness (in.)
N/A Dia. ID (ft & in.)
21 No.
Length overall (ft & in.)
31' 0o When applicable, Certificate Holder's Data Reports are attached for each Item of this report:
Part or Appurtenance National Part or Appurtenance National Serial Number Board No.
Serial Number Board No.
In Numerical Order In Numerical Order
: 8.
9.


FORM N-2 (Back - Page 2 of                           2 Certificate Holders Serial Nos.         Ht # 245951               through     1,2,4.5.7,8,9 CERTIFICATION OF DESIGN P.E. State                 CA             Reg. No_         13655 Design Specifications certified by'                          Boyd P. Brooks (when applicable)
FORM N-2 (Back - Page 2 of 2
P.E. State                 MA             Reg. No..         10981 Design Report* certified by                                Herbert Cook (when applicable)
Certificate Holders Serial Nos.
CERTIFICATE OF COMPLIANCE 21' MSIV Valve Poppets We certify that the statements made in this report are correct and that this (these) conform(s) to the rules for construction of the ASME Code, Section Il1,Division 1.                                 xpiresr                13, 2004 NPT Certificate of Authorization No.         N-2873 12-10-01             Name       Welding Services Inc.                                 Signe4 N I                 .&#xfd;         L. 3 I Date                                                                                                            \        "          authorized reprerentalive)
Ht # 245951 through 1,2,4.5.7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by' Boyd P. Brooks P.E. State CA Reg. No_
(NPT Cerlificate Holder)
13655 (when applicable)
                                                                                                        --- --- .U...
Design Report* certified by Herbert Cook P.E. State MA Reg. No..
CERTIFICAT             -.
10981 (when applicable)
uI     INbFrIL, I IIJJn and Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board of Boiler and employed     by       The Hartford Steam Boiler Inspection and Insurance Co.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section Il1, Division 1.
Georgia                                                                                                                                                    and state that to the have inspected these   items described in this Data Report on         December 10, 2001 of      Hartford,. CT                                                                                                                          with  ASME    Code, Section III.
NPT Certificate of Authorization No.
parts  or  appurtenances    in  accordance best of my knowledge and belief, the Certificate Holder has fabricated these has been authorized for stamping   on the date shown   above.
N-2873 xpiresr 13, 2004 Date 12-10-01 Name Welding Services Inc.
D'ivision 1. Each part listed described "By signing this certificate, neither the inspector nor hishisemployer    makes any warranty, expressed or implied, concerning the equipment be liable in any manner   for any   personal   injury or property damage     or loss in this Data Report. Furthermore, neither the inspectoror                employer, shall of any kind arising from or connected wi this insp*             ,rtion.
Signe4 N I  
Signed                                                       Commissions           NB # 11465 ABN, GA # 393 Date      12-10-01                                                                                                    Bd. (incl. Endorsements) and stale or prov. and no.]
.&#xfd; L.
S(Authi                            .Nati.
3 I (NPT Cerlificate Holder)  
F 1V.ibrary_ssvr~quaity.a Project FilestAtwood & MornZlO1t3 1140 )Oct 200 I)W2-31140.doc
\\
authorized reprerentalive)
--- ---.U...
CERTIFICAT uI INbFrIL, I IIJJn I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section III.
D'ivision 1. Each part listed has been authorized for stamping on the date shown above.  
"By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspectoror his employer, shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this insp*  
,rtion.
Date 12-10-01 Signed Commissions NB # 11465 ABN, GA # 393 S(Authi
.Nati.
Bd. (incl. Endorsements) and stale or prov. and no.]
1V.ibrary_ssvr~quaity.a Project FilestAtwood & MornZlO1 t3 1140 )Oct 200 I)W2-31140.doc F


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                   Pg. 1 of 2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by               Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 2. Manufactured for           Pennsylvania Power & Light                       Berwick, PA             18603 (name and address Or Purchaser)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address Or Purchaser)
: 3. Location of installation           Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 4. Type:           *32162-409-D Rev. 1                       SA 105 GR II                        80.000 PSI                                  N/A                        2001 2001 (dr-avwg no.)                   SA   105 (marl.       no,) 11 spe, GR                    (tensile strength)                        IGRN)                    (year buil)
: 4. Type:  
S. ASME Code, Section III, Division 1:                          1971                          S71                               1                                N/A (eSOM)                    (Oadends Oats)                      Icissal l*ass?                        !Code Case no.)
*32162-409-D Rev. 1 (dr-avwg no.)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                           N/A             Revision               N/A             Date                 N/A (no.)
S. ASME Code, Section III, Division 1:
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 2 Cover A&M P/N 32162-409-2974-000 QLA' (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
SA 105 GR II (marl. spe, no,)
: 8. Nom. Thickness (in.)           5.312       Min. design thickness (in.)             5.094       Dia. ID (ft & in.)           N/A         Length overall (Rt&In.)           N/A
1971 80.000 PSI (tensile strength)
S71 (eSOM)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(Oadends Oats)
N/A (no.)
Icissal Revision N/A Date
!Code Case no.)
N/A
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 2 Cover A&M P/N 32162-409-2974-000 QLA' (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
: 8. Nom. Thickness (in.)
5.312 Min. design thickness (in.)
5.094 Dia. ID (ft & in.)
N/A Length overall (Rt& In.)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:
Part or Appurtenance                           National                                  Part or Appurtenance                                National Serial Number                             Board No.                                        Serial Number                                Board No.
N/A Part or Appurtenance Serial Number (1)
In Numerical Order                                                                            In Numerical Order (1)   HT: H3391 SIN 7                               N/A                              (25)
HT: H3391 SIN 7  
    -. (2)   HT: H3391 S/N 8                               NIA                              (27)
-. (2)
(3)                                                                                   (28)
HT: H3391 S/N 8 (3)
(4)                                                                                   (29)
(4)
(5)                                                                                   (30)
(5)
(6)                                                                                   (31)
(6)
(7)                                                                                   (32)
(7)
(8)                                                                                   (33)
(8)
(9)                                                                                   (34)
(9)
(10)                                                                                   (3S)
(10)
(11)                                                                                   (36)
(11)
(12)                                                                                   (37)
(12)
(13)                                                                                   (38)
(13)
                                            +                               --              1                                           'I                                      4 (14)                                                                                   (39) 4 (15)                                                                                   (40) 4 (16)                                                                                   (41)
(14)
(17)                                                                                   (42) 1-(18)                                                                                   (43)
(15)
                                            +
(16)
(19)                                                                                   (44)
(17)
(20)                                                                                   (45) 1 (21)                                                                                   (46) 4.
(18)
(22)                                                                                   (47) 4    -
(19)
(23)                                                                                     (48)
(20)
(24)                                                                                     (49)
(21)
(25)                                                                                     (50)
(22)
: 10. Design pressure                 1250           psi. Temp.                 575           IF. Hydro. test pressure                         N/A                At temp. "F (whan appiacable)
(23)
"Supplemental Information numbered in the form of lists sketches, or drawIngs may be used provided (1) size Is       %. x 11, 12) Information In items 2 and 3 on this Data Report is Included on each sheet Is           and the number of sheets Is recorded at the top of this form.
(24)
(112191)                              This form (EO0040) may be obtained from the Order Dept.. ASME, 22 Law Drive, Box 2300, Fairfield, N.J07007-2300.
(25)
National Board No.
In Numerical Order N/A NIA
+
1 4
4 1-
+
1
4.
4 Part or Appurtenance Serial Number (25)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)
(3S)
(36)
(37)
(38)
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
National Board No.
In Numerical Order
'I 4
: 10. Design pressure 1250 psi.
Temp.
575 IF. Hydro. test pressure "Supplemental Information in the form of lists sketches, or drawIngs may be used provided (1) size Is  
.% x 11, 12) Information In items 2 and 3 on this Data Report is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
This form (EO0040) may be obtained from the Order Dept.. ASME, 22 Law Drive, Box 2300, Fairfield, N.J 07007-2300.
Reprint (7I 31)
Reprint (7I 31)
N/A IGRN) 1 2001 (year buil)
N/A N/A (whan appiacable)
At temp. "F SA 105 GR 11 2001 l*ass?
(112191)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.             HT: H3391 S/N 7                     through         S/N 8 CERTIFICATION OF DESIGN P.E. State              N/A            Reg. no.                          N/A Design specifications certified by                         N/A (when applicable)
Certificate Holders' Serial Nos.
P.E. State             N/A            Reg. no.                           N/A Design report    certified by                          N/A (when appiIklbIle CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these)                                                     Cover conforms to the rules of construction of the ASME Code, Section III, Division 1.
HT: H3391 S/N 7 through S/N 8 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A (when applicable)
NPT Certificate of Authorization No.                          N2607                          Expires                                        6-13-04          .
N/A (when appiIklbIle P.E. State P.E. State CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
Signed Date           /zi4                   Name             Atwood & Morrill Co., Inc.
NPT Certificate of Authorization No.
(NPT Certifcate Holder)                                                   "(S~uth~ozed represetat")
Date  
CERTIFICATE OF INSPECTION Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure New York                  And employed by                                                         H.S.B.I & I. Co.
/zi4 Name N2607 Expires Atwood & Morrill Co., Inc.
-f               Hartford, CT                 have inspected these items described in this Data Report on                         ,/             .          , and state that to the Holder   has   fabricated   these   parts or appurtenances     in accordance       with the ASME     Code, Section
(NPT Certifcate Holder) 6-13-04 Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.
    ,st of my knowledge and belief, the Certificate
-f Hartford, CT have inspected these items described in this Data Report on  
,,I, Division 1. Each part listed has been authorized for stamping         on the date   shown   above.
,/  
or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed neither the inspector   nor   his employer   shall be liable in any   manner     for any personal injury or property damage or in this Data Report. Furthermore, loss of any kind arising from   or connected   with this inspection.
, and state that to the  
Date       A.1                 Signed                                                       _        _Commissions               _4-. X-_-         7e (authorized inslpeto*                                           (Narl 8d:. (inc. Endorsements) end state of prov. ari rno.i
,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section  
,,I, Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date A.1 Signed
_Commissions
_4-. X-_-
7e N/A N/A Reg. no.
Reg. no.
N/A N/A Cover New York (authorized inslpeto*
"(S~uth~ozed represetat")
(Narl 8d:. (inc. Endorsements) end state of prov. ari rno.i


FOR IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA REPORT NUCLEAR PARTS AND                             APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
Section III As Required by the Provisions of the ASME Code,                                                                             Pg. 1 of 2 Not to Exceed               One     Day's       Production Atwood & Morrill Co., Inc. 285 CanalHolder)                      Street Salem, MA 01970
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by (name and address of NPI' Ce*tificate Pennsylvania Power & Light
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPI' Ce*tificate Holder)
* Berwick,                               PA .18603
: 2. Manufactured for Pennsylvania Power & Light
: 2. Manufactured for                                                                        (name and address of Purchaser) 18101-1179
* Berwick, PA.18603 (name and address of Purchaser)
: 3. Location of installation           Susquehanna 11 2 North Ninth Street Allentown, PA (name and address) 85,700 PSI                                  N/A                        2001
: 3. Location of installation Susquehanna 11 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 4. Type:           *32462-613-C Rev.0                           SA 479-304                                                                       (CRN)                      (year built)
: 4. Type:  
(marl. spec. no.)                   (tensile stren-th)
*32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)
(drawing no.)
(marl. spec. no.)
S71                                1                              N/A
(tensile stren-th)
: 5. ASME Code, Section III, Division 1:                         .1971                                                             (class)                       (Code Cate no.)
(CRN)
(edibon)                    (addenda date)
(year built)
N/A            Revision              N/A            Date                  N/A
: 5. ASME Code, Section III, Division 1:  
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only) 32462-613-4226-121 QLA
.1971 S71 1
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N prepared by A&M.               This     certification         meets     the required information of ASME
N/A (edibon)
          &M S.. 90168 Section III 1971 Edition Summer 1971 addenda 1.36         Dia. ID (ft & in.)         N/A . Length overall (ft& in.)                 N/A
(addenda date)
: 8. Nom. Thickness (in.)            1.50        Min. design thickness (in.)
(class)
are attached for each Item of this report
(Code Cate no.)
: 9. When applicable, Certificate Holders' Data Reports I %-I C    10. Design pressure                   1250           psi,     Temp.               575           'F. Hydro. test pressure                         N/A (when applicable)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
At temp. F Is 11, (2) Information In Items 2 and 3 an this Data Report or drawings may be used provided (1) size Is a % x
N/A Revision N/A Date N/A
    *Supplemental information In the form of lists, sketches,        Is recorded   at the top of this form.
: 7. Remarks:
and the number  of sheets Included on each sheet Is numbered Reprint (TI S1)
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA
ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007.2300.
&M S..
(12188)                              This lorm (E00040) may be obtained from the Order DepL.
90168 prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
: 8. Nom. Thickness (in.)
1.50 Min. design thickness (in.)
1.36 Dia. ID (ft & in.)
N/A  
. Length overall (ft& in.)
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report C
I %-I
: 10. Design pressure 1250
: psi, Temp.
575  
'F. Hydro. test pressure N/A At temp. F (when applicable)  
*Supplemental information In the form of lists, sketches, or drawings may be used provided (1) size Is a % x 11, (2) Information In Items 2 and 3 an this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(12188)
This lorm (E00040) may be obtained from the Order DepL. ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007.2300.
Reprint (TI S1)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.           HT: 54682 S/N 1               through           S/N 6, 8 & 9 CERTIFICATION OF DESIGN P.E. State        N/A            Reg. no.                            N/A Design specifications certified by                         N/A (when sppica ble)
Certificate Holders' Serial Nos.
P.E. State         N/A             Reg. no.                           N/A Design report* certified by                            N/A (when applicable)
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by N/A (when sppica ble)
CERTIFICATE OF COMPLIANCE (these)                                Pilot Poppet We certify that the statements made in this report are c6rrect and that this of the ASME   Code,   Section   III, Division 1.
Design report* certified by N/A (when applicable)
conforms to the rules of construction N2607                          Expires                                6-13-04              a NPT Certificate of Authorization No.
P.E. State N/A P.E. State N/A Reg. no.
Name            Atwood & Morrill Co., Inc.                     Signed     A           7
N/A Reg. no.
                                                                                                                                        .tn-d&#xfd; ,,,t/
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are c6rrect and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
a~ol~       t-rwtbI Date                                                                                                             J   =
NPT Certificate of Authorization No.
N2607 Pilot Poppet Expires Atwood & Morrill Co., Inc.
(NPT~ Certficate Holder)
Signed A  
.tn-d&#xfd; 7
a~ol~
t-rwtbI CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.
"Hartford, CT have inspected these items described in this Data Report on g,".7, /
, and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord rncerwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions
.fJX?"76 A
1 /
Date Name
,,ole
!poizdinpecor
-/7
./
*'Narl Bd. Cindl. en:kmroms) wnd sata or prow. and no.]
6-13-04 a
6-13-04
,,,t/
J  
=
(auth~orzed rapfesetab")
(auth~orzed rapfesetab")
(NPT~Certficate Holder)                                            6-13-04 CERTIFICATE OF INSPECTION of Board of Boiler and Pressure Vessel Inspectors and the State or Province I. the undersigned, holding a valid commission Issued by the National And employed by                                                  H.S.B.I &      I.Co.
New York                                                                                                                                  ,and state that to the items  described  in this Data Report  on        g,".7, /
                "Hartford, CT                  have inspected these parts or appurtenances in accord      rncerwith      the  ASME      Code, Section st of my knowledge and belief, the Certificate Holder has fabricated these Division 1. Each part listed has been authorized for stamping on the date shown above.
any warranty, expressed or implied, concerning the equipment described By signing this certificate, neither the Inspector nor his employer makes                                                                                                        or neither the  inspector  nor  his  employer    shall be liable in any manner for any personal injury or property damage in this Data Report. Furthermore, loss of any kind arising from or connected with this inspection.
          -/7  ./
                                    ,,ole                      !poizdinpecor                          Commissions        .fJX?"76
                                                                                                                        *'Narl Bd. Cindl. en:kmroms)
A  1
                                                                                                                                                              /
wnd sata or prow. and no.]


FORM NR-1           REPORT OF REPAIRX]                   MODIFICATION ED                   OR REPLACEMENT                 1]
FORM NR-1 REPORT OF REPAIRX]
MODIFICATION ED OR REPLACEMENT 1]
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 1. Work performed by       Continental             Field       Systems,             TNc                           3218 (name of NR certifcate holder)                                           (P.O. no., job no., etc.)
: 1. Work performed by Continental Field Systems, TNc 3218 (name of NR certifcate holder)
23 Westgate           Blvd,       .Savannah,         GA 31405 (address)
(P.O. no., job no., etc.)
: 2. Owner       PPL       LLC (name) 2 North Nintb Strept,                     Allentnurn             PA 1Rl01 (address)
23 Westgate Blvd,  
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 M1-i       N-rth nf Rprwirk                   PA                           Snlm Twp: PA
.Savannah, GA 31405 (address)
: 4. System   1-62A                   HV141FO22D                           Main       Steam
: 2. Owner PPL LLC (name) 2 North Nintb Strept, Allentnurn PA 1Rl01 (address)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                       See Attached Identification                                                       Construction Code                             Activity Type of     Mfg.       Mfg.     Nat'l Bd. Jurisd.       Other       Year         Name/         Edition/         Code         Code         Repair/
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 M1-i N-rth nf Rprwirk PA Snlm Twp: PA
No   Item     Name       Serial No. No.           No.                   Built       Section/       Addenda         Case(s)       Class         Mod/
: 4. System 1-62A HV141FO22D Main Steam
Division                                                   Replace 2
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
11 12
11 12
: 5. b: Items Installed During Replacement Activities                     ,See Ar~tnnhed Identification                                                               Construction Code Type of   Installed or. Mfg.         Mfg         Nat'l Bd.       Jurisd     Other       Year       Name/       Edition/         Code       Code Item       Replaced       Name       Serial No.       No.           No                 Built       Section/     Addenda Case(s)               Class 5a Item No.                                                                                 Division
: 5. b: Items Installed During Replacement Activities  
: 6. ASME Code Section )a applicable for inservice inspection:               1989                         N/                         N/A
,See Ar~tnnhed Identification Construction Code Type of Installed or.
                                                                                            -(edition)               N ' "(addenda)               ""(Code Cas       $~))
Mfg.
: 7. ASME Code Section MI used for repairs, modifications, or replacements:                 19 A                   N. A-                   N/A (edition)         (addenda)               (Code Cases(s))
Mfg Nat'l Bd.
: 8. Construction Code used .for repairs, modifications, or replacements:                   19 71                   S 71                 N/A (edition)           (addenda)               (Code Casess))
Jurisd Other Year Name/
: 9. Design responsibilities:       Atwoodl & Morrill Co.
Edition/
10, Tests conducted: hydrostatic El     pneumatic El       design pressure D]           pressureNJA__         psi Code Case(s)
Code Code Item Replaced Name Serial No.
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                       Rev. 8
No.
 
No Built Section/
I--
Addenda Case(s) Class 5a Item No.
I
Division
: 6. ASME Code Section )a applicable for inservice inspection:
1989 N/
N/A  
-(edition)
N  
"(addenda)  
""(Code Cas  
$~))
: 7. ASME Code Section MI used for repairs, modifications, or replacements:
19 A N.
A-N/A (edition)
(addenda)
(Code Cases(s))
: 8. Construction Code used.for repairs, modifications, or replacements:
19 71 S 71 N/A (edition)
(addenda)
(Code Casess))
: 9. Design responsibilities:
Atwoodl & Morrill Co.
10, Tests conducted: hydrostatic El pneumatic El design pressure D]
pressureNJA__
psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
: 11. Description of work:
: 11. Description of work:
A Sea Attairlprl (use of properly identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks:     See Attached Manufacturer's                               Data Report CERTIFICATE OF COMPLIANCE I,   David McCathie                 certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
Sea Attairlprl (use of properly identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks: See Attached Manufacturer's Data Report I--
National Board Certificate of Authorization No.             NR-86                     to use the "NR" stamp expires 525.j/2                     2003 NR Certificate Holder       rrnn       pntal           Jeld       Sytrws               Inc Date   6.L1B. 2.0DI1L Signed                                     ~ )Qual1ity                      -a~d           Conf~   V*-.. Maae
CERTIFICATE OF COMPLIANCE I,
                                                                                                                            .. Ti]e:      aac
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
                                                  --(authohzed re-presentative)
National Board Certificate of Authorization No.
CERTIFICATE OF INSPECTION I, Ws o. tA. e- 1?. r -i         Br, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of F;eN N SYLV -                               Ai4        --- and employed by i.4cTgRy MUTrUA             LVJLVC           C-2 COMP',4/v'                               of Z'JOtrA,                 "*r                             have inspected the repair, modification or replacement described in this report on                       4
NR-86 to use the "NR" stamp expires 525.j/2 2003 NR Certificate Holder rrnn pntal Jeld Sytrws Inc Date 6.L1B.
* I           Z0 0 ?         and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codeand the National Board Inspection Code "NR" rules.
2.0DI1L Signed  
-a~d  
~
)Qual1ity Conf~ aac  
--(authohzed re-presentative)
V*-..
Ti]e: Maae CERTIFICATE OF INSPECTION I, Ws o. tA.
e-1?. r -i Br, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of F;eN N SYLV -
Ai 4
and employed by i.4cTgRy MUTrUA LVJLVC C-2 COMP',4/v' of Z'JOtrA,  
"*r have inspected the repair, modification or replacement described in this report on 4
* I Z 0 0 ?
and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codeand the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
5
(inspec
              &#xfd;Z   ZOOZ Signed                           (inspec ?                          CommissionsA,87982A&Z or?(       nd0-s,         urd-DNS PAdZZo4 (inspector~'                         (National Board (cin. endorsements), jurisdiction, and no.)
&#xfd;Z ZOOZ Signed or?(
5 ?
nd0-s, urd-CommissionsA,87982A&Z DNS PAdZZo4 (inspector~'
(National Board (cin. endorsements), jurisdiction, and no.)
I A


Form NR-1 Attachment                                               Report of Repair / Replacement Worked Performed by Continental Field Systems                                                       Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D Items Which Required Repair, Modification, or Replacement Activities Identification                                                                                                           Construction Code No         Type of Item         Mfg. Name   Mfg. Serial     Nat'l Bd. Jurisdiction       Other       Year     Name/ Section/     Edition /       Code     Code Class       Repair/
Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D Items Which Required Repair, Modification, or Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Construction Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.
                                                  #            No.           No.                       Built       Division         Addenda         Case(s)                     Replace I           MSIV               A&M         4-221           N/A           N/A           N/A         1974     ASME 11 fNB       1971/S71       1535-2       I             Repair 2
Jurisdiction Other Year Name/ Section/
Items Installed During Replacement Activities Identification                                                                                                           Construction Code Item           Installed/     MFG.       Mfg. Serial         Nat'l       Jurisd. No. Other     Year Built       Name/           Edition/     Code           Code Replaced       Name             No.         Bd. No.                                                 Section/         Addenda       Case(s)         Class Division Poppet           Replaced         WSI             9           N/A             N/A         N/A         2001           111 NB       71 Ed. S71 A     N/A].
Edition /
flnnnot         P anl grpd       A 1kM           q           N/A             N/A         N/A         2001           III NB       71 Ed. S/1 A     N/A             I Pilot Poppet       Replaced~ A&M                     9           NA{             N/A         N/A~       2001           111INB       71 Ed. S71 A     N/A       ___
Code Code Class Repair/
Super Nuts         ~Replaced~ A&M               NU-0 10 17         N/A             N/A___       N/A         2002           111INB       71lEd. S71 A     N/Aj             I j0f     2
No.
No.
Built Division Addenda Case(s)
Replace I
MSIV A&M 4-221 N/A N/A N/A 1974 ASME 11 fNB 1971/S71 1535-2 I
Repair 2
Items Installed During Replacement Activities Identification Construction Code Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced WSI 9
N/A N/A N/A 2001 111 NB 71 Ed. S71 A N/A].
flnnnot P anl grpd A
1kM q
N/A N/A N/A 2001 III NB 71 Ed. S/1 A N/A Pilot Poppet Replaced~ A&M 9
NA{
N/A N/A~
2001 111INB 71 Ed. S71 A N/A Super Nuts  
~Replaced~ A&M NU-0 10 17 N/A N/A___
N/A 2002 111INB 71lEd. S71 A N/Aj I
j0f 2
I


Form NR-1 Attachment                                         Report of Repair / Replacement
Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems Job Number 3218
(
(
Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Job Number 3218 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D
: 6. ASME Code Section X1 applicable for inservice inspection: 1989                   N/A             N/A (edition)           (addenda)       (Code Case(s))
: 6. ASME Code Section X1 applicable for inservice inspection: 1989 N/A N/A (edition)
: 7. ASME Code Section XI used for repairs, modifications, or replacements: 1989             N/A               N/A (edition)         (addenda)         (Code Case(s))
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:   1971             Summer 71         I (edition)         (addenda)         Code Case
(Code Case(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements: 1989 N/A N/A (edition)
(addenda)
(Code Case(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 Summer 71 I
(edition)
(addenda)
Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
: 12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.
Line 1,194: Line 2,376:


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of         2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by                                     Welding Services, Inc. 2225 Skyland Court, Norcross GA. 30071 (name and address of NPT Certificate Holder)
: 1.
: 2. Manufactured for                                              Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
Manufactured and certified by
: 3. Location of installation                                        PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
: 2.
: 4. Type:         A&M       D-               SA 105 Gr.U                       70.0 Ksl                                   N/A                               2001 32467-622 R/7 (drawing no.)             (mall. spec. no.)               (tensile strength)                           (CRN)                           (year built)
Manufactured for
: 5. ASME Code, Section III, Division 1:                     1971                       S 1971                                 1                             N/A (edition)               (addenda dale)                         (class)                     (Code Case no.)
: 3.
: 6.     Fabricated'in accordance with Const. Spec. (Div. 2 only)                           N/A               Revision                   N/A           Date             N/A (no.)
Location of installation Welding Services, Inc. 2225 Skyland Court, Norcross GA. 30071 (name and address of NPT Certificate Holder)
: 7.     Remarks:       21" MSIV Valve Poppet SA 105 Gr.ll with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat # 245951 for SA 105 Gr. I1 21 "Heat #s   00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite Nom. Thickness (in.)       N/A           Min. design thickness (in.)       N/A               Dia. ID (ft &in.)    o21' ODNor.        Length overall (ft & In.)    31" 8.
Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
: 9.     When applicable, Certificate Holder's Data Reports are attached for each It National                                    Part or Appurtenance                           National Part or Appurtenance                                                                          Serial Number                             Board No.
PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
Serial Number                          Board No.
: 4.
In Numerical Order In Numerical Order (1)  94,.S 1-1                                                                      (26)                                           4.
Type:
2ArQ1 -,
A&M D-SA 105 Gr.U 70.0 Ksl N/A 2001 32467-622 R/7 (drawing no.)
245951-1                                                              (27)
(mall. spec. no.)
(2)                                                                                         _________________________________       4.
(tensile strength)
245951-
(CRN)
              )AlQvi,.A                                                                     (28)
(year built)
(3)                                   I                                                                                            I1
: 5.
            ')ArGXZiA                                                                      (29)
ASME Code, Section III, Division 1:
(4)   245951-5 245951-5                                                                        (30)
1971 S 1971 1
(5)   245951-7 245951-7 245951-8                                                                       (31)
N/A (edition)
(6) 245951-8 245951 -g                                                                      (32) 245951-9                                                                        (33)
(addenda dale)
(class)
(Code Case no.)
: 6.
Fabricated'in accordance with Const. Spec. (Div. 2 only)
N/A Revision N/A Date N/A (no.)
: 7.
Remarks:
21" MSIV Valve Poppet SA 105 Gr.ll with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat # 245951 for SA 105 Gr. I1 "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21
: 8.
Nom. Thickness (in.)
N/A Min. design thickness (in.)
N/A
: 9.
When applicable, Certificate Holder's Data Reports are attached for each It Part or Appurtenance Serial Number
: 10.
* Design pressure National Board No.
In Numerical Order
1 NIA psi.
Temp.
245951-1 245951-4.
4.
4.
4.
+
Dia. ID (ft & in.)
21' Nor.
Length overall (ft & In.)
31" o OD Part or Appurtenance Serial Number (26)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37) 4.
_________________________________ 4.
I1 i
National Board No.
In Numerical Order (40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
N/A "F
Hydro. test pressure N/A at temp. 'F (when applicable)
"Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8% x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/88)
This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
Reprint (7/91 )
ttLjbrarysvrtquality aP*froject FiestArwood & MorrIIA2001%31140 )Oct 2001)W2-31140.doc 94,.S 1-1 2ArQ1
)AlQvi,.A 245951-5 245951-7 245951-8 245951 -g (1)
(2)
(3)
(4)
(5)
(6)
(8)
(8)
(9)                                    I                                            (34)
(9)
(10)                                                                                    (35)
(10)
(36)
(11)
(11)
(12)                                                                                  (37) 1 )4               ""                                                                          ______          _________            i (15)                                                                                    (40)
(12) 1 )4 (15)
: 4.                                            (41)
(16)
(16)                                    4.                                              (42)
(17)
(17)                                   4.
(18)
(18)                                                                                    (43)
(19)
: 4.                                              (44)
(20)
(19)                                    +                                              (45)
(20) 1 (46)
(21)
(21)
(22)                                                                                    (47)
(22)
(48)
(23)
(23)
(49)
(24)
(24)
(25)                                       _____________
(25)
(50)
')ArGXZiA I
N/A          "F    Hydro. test pressure              N/A              at temp. 'F
245951-5 245951-7 245951-8 245951-9 I
: 10.
* Design pressure                      NIA                      psi. Temp.
(when applicable) x 11, (2) information in items 2 and 3 on this "Supplemental    information in the form of lists, sketches, or drawings may be used provided (1) size is 8%
sheets is  recorded  at the top of this form.
Data Report is included orn each sheet, (3) each sheet is numbered and the number of Box 2300, Fairfield, NJ 07007-2300.
(12/88)                                    This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive,                                              Reprint (7/91 )
ttLjbrarysvrtquality aP*froject FiestArwood & MorrIIA2001%31140)Oct 2001)W2-31140.doc


FORM N-2 (Back - Page 2 of                         2   )
FORM N-2 (Back - Page 2 of 2 )
Certificate Holder's Serial Nos. Ht # 245951             through       1,2,4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by-                       Boyd P. Brooks                         P.E. State                 CA             Reg. No.           13655 (when applicable)
Certificate Holder's Serial Nos.
Design Report* certified by                             Herbert Cook                               P.E. State                 MA             Reg. No..           10981 (when applicable)
Ht # 245951 through 1,2,4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by-Boyd P. Brooks P.E. State CA Reg. No.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)           21" MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III. Division 1.
13655 (when applicable)
NPT Certificate of Authorization No.       N-2873                                                           x res(J               r 13, 2004 Date     12-10-01               Name       Welding Services Inc.                             Signe       NI    i     ,    "    Lo t5.Q _
Design Report* certified by Herbert Cook P.E. State MA Reg. No..
(NPT   Cerlificate Holder)                                             (authorized representativ*)
10981 (when applicable)
CERTIFICATE OF INSPECTION I              I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia                                                                     and employed by       The Hartford Steam Boiler Inspection and Insurance Co.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21" MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III. Division 1.
of     Hartford,. CT                   have inspected these items described in this Data Report on           December 10, 2001                 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code. Section III.
NPT Certificate of Authorization No.
N-2873 x res(J r 13, 2004 Date 12-10-01 Name Welding Services Inc.
Signe N I i
Lo t5.Q (NPT Cerlificate Holder)
(authorized representativ*)
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code. Section III.
Division 1. Each part listed. has been authorized for stamping on the date shown above.
Division 1. Each part listed. has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected w11 this ins     ion.         I               ,
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected w11 this ins ion.
Date     12-10-01           Signed                                                     Commissions       NB # i1465 ABN, GA# 393 S(Aut i                   I       .[Nall.                     Bd. (incl. Endorsements) and state or prov. and no.]
I Date 12-10-01 Signed Commissions NB # i1465 ABN, GA# 393 S(Aut i
I  
.[Nall.
Bd. (incl. Endorsements) and state or prov. and no.]
%ibrarysvriquaity_a
%Project FilestAtwood & Morrl#l2001131140 )Oct 2001)W2-31140.doc I
i
i
  %ibrarysvriquaity_a    %ProjectFilestAtwood & Morrl#l2001131140 )Oct 2001)W2-31140.doc


FOR IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA REPORT NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
III As   Required         by the Provisions of the ASME Code, Section Day's       Production                                           Pg. 1 of 2 Not to Exceed One Atwood & Morrill Co., Inc. 285 Canal Street                                     Salem, MA 01970
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by (name and address of NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 2. Manufactured for         Pennsylvania Power & Light                         Berwick, PA 18603 (name and address of Purchaser)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
: 3. Location of installation         Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address) 81,500PSI                                  N/A                        2001
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 4. Type:           *32162-409-D Rev. 1                         SA 105 GR II                                                                                               (year "M isnaile strengthi)                      (CRNM (drawing no.)                         (marl spec- no.)
: 4. Type:  
S71                                1                              N/A
*32162-409-D Rev. 1 SA 105 GR II 81,500PSI N/A 2001 (drawing no.)
: 5. ASME Code, Section III, Division 1:                           1971                                                                                           (Coda Case no.)
(marl spec-no.)
(addenda data)                       (class)
isnaile strengthi)
(odibon)
(CRNM (year "M
N/A              Revision              N/A            Date                  N/A
: 5. ASME Code, Section III, Division 1:
1971 S71 1
N/A (odibon)
(addenda data)
(class)
(Coda Case no.)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(no.)
N/A Revision N/A Date N/A (no.)
QLA
: 7. Remarks:
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 1 Cover A&M P/N 32162-409-2974-000                                                                             of ASME certification meets the                required      information (A&M S.O. 90168) -Dw. Repared by A&M. This Section III 1971 Edition summer 1971 addenda 5.094.         DIa. ID (ft & In.)         N/A         Length overall (ft& in.)         N/A B. Noa. Thickness (in.)          5.312        Min. design thickness (in.)
Cust. Item 01 A&M Item 11 Qty. 1 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) -Dw.
are attached for each item of this report:
Repared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda B. Noa. Thickness (in.)
: 9. When applicable. Certificate Holders' Data Reports Part or Appurtenance                               National Part or Appurtenance                           National                                                                                       Board No.
5.312 Min. design thickness (in.)
Board No.                                           Serial Number Serial Number                                                                                                                        In Numerical Order In Numerical Order N/A                                (26)
5.094.
(1)    HT: H3391 SIN 9 (27)
DIa. ID (ft & In.)
N/A Length overall (ft& in.)
N/A
: 9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:
Part or Appurtenance National Part or Appurtenance National Serial Number Board No.
Serial Number Board No.
In Numerical Order In Numerical Order (1)
HT: H3391 SIN 9 N/A (26)
(2)
(2)
(27)
(3)
(28)
(28)
(3)
(4)
(29)
(29)
(4)
(5)
(30)
(30)
(5)                                                                                      (31)
(6)
(6)
(31)
(7)
(32)
(32)
(7)
(8)
(33)
(33)
(8)
(9)
(34)
(34)
(9)
(10)
(35)
(35)
(10)
(11)
(36)
(36)
(11)
(12)
(37)
(37)
(12)                                                                                        "3)
(13) --
(13) --
"3)
(14)
(39)
(39)
(14)
(15)
(40)
(40)
(15)
(16)
(41)
(41)
(16)
(17)
(42)
(42)
(17)
(18)
(43)
(43)
(18)
(19)
(44)
(44)
(19)
(20)
(45)
(45)
(20)
(21)
(46)
(46)
(21)
(22)
(47)
(47)
(22)
(23)
(48)
(48)
(23)
(24)
(49)
(49)
(24)
(25)
(50)
(50)
(25)
: 10. Design pressure 1250 psi.
Hydro. test pressure                     N/A                Attemp.
Temp.
1250             psi. Temp.               575           'F.                                     _F
575  
: 10. Design pressure                                                                                                                         (when applcable)
'F.
IS x i. (2) Information In items 2 and 3 on this Data Report or drawings may be used provided (1) size is S Y.
Hydro. test pressure N/A Attemp.
    *Supplemental Information In the form of lists, sketches,                          the top of this form.
_F (when applcable)  
and the number  of sheots  Is recorded  at Included on each sheet Is numbered Reprnt (71 51)
*Supplemental Information In the form of lists, sketches, or drawings may be used provided (1) size is S Y. x i. (2) Information In items 2 and 3 on this Data Report IS Included on each sheet Is numbered and the number of sheots Is recorded at the top of this form.
ASME. 22 Low Drive, sox 2300, Fairfield. NJ 07007-2300.
(121881 This form (E00040) may be dibtained from the order Dept.. ASME. 22 Low Drive, sox 2300, Fairfield. NJ 07007-2300.
(121881                            This form (E00040) may be dibtained from the order Dept..
Reprnt (71 51)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
HT: H3391 S/N 9             through         SIN N/A Certificate Holders' Serial Nos.
Certificate Holders' Serial Nos.
CERTIFICATION OF DESIGN P.E. State         N/A         Reg. no.                       N/A
HT: H3391 S/N 9 through SIN N/A CERTIFICATION OF DESIGN ions certified bv N/A P.E. State N/A Reg. no.
          -.      .-      ions  certified bv                      N/A Design    spec      -  -      -  -                    (- =
N/A Design report certified by N/A (whein applicable)
tw      pplicable)
P.E. State N/A Reg. no.
P.E. State         N/A         Reg. no.                       N/A Design report certified by                                  N/A (wheinapplicable)
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
CERTIFICATE OF COMPLIANCE Cover are correct and that this (these)
NPT Certificate of Authorization No.
We certify that the statements made In this report Section III, Division 1.
Date N2607 Name Atwood & Morrill Co., I (NPT Cartifate H-ker)
conforms to the rules of construction of the ASME Code, Expires                              6-13-04 N2607 NPT Certificate of Authorization No.
Expires 6-13-04 ri.
Name           Atwood & MorrillH-ker)  Co., I       ri. Signed Date                                                                    (NPT Cartifate CERTIFICATE OF INSPECTION Vessel inspectors and the State or Province of issued by the National Board of Boiler and Pressure I
Signed CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New York And employed by H.S.B.I & 1. Co.
I. the undersigned, holding a valid commission H.S.B.I & 1. Co.
Hartford, CrT have inspected these iters described in this Data Report on
New York                      And employed by                                                                                  , and state that to the in this Data Report on Hartford,     CrT             have inspected these iters described                                                 the ASME    Code, Section in accordance *ith Holder has fabricated these parts or appurtenances
, and state that to the  
  .. est of my knowledge and belief, the Certificate for stamping on the date shown above.
.. est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance *ith the ASME Code, Section III, Division 1. Each part listed has been authorized for stamping on the date shown above.
III, Division 1. Each part listed has been authorizedhis employer makes any warranty, expressed or implied, concerning the equipment described the inspector nor                                                                                                 damage or By signing      this certificate, neither                                                              any manner for any personal Injury or property inspector nor his employer shall be liable in in this Data Report. Furthermore, neither the this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.
loss of any kind arising from or connected with Commissons     ~ )SZ7                 ~
Date
Signed                                                                                                                        and mi.
~
(NaV ad. (wic.lEndarerneaml) amda~ta- w prow.
~/
Date      ~            ~/
Signed Commissons  
j     w i
~ )SZ7  
~
(NaV ad. (wic. lEndarerneaml) amd a~ta-w prow.
and mi.
Design spec Cover i
(- =
tw pplicable)
I j
w


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Pg. I of 2 Not to Exceed One Day's Production
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of 2
: 1. Manufactured and certified by               Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cerficate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cerficate Holder)
: 2. Manufactured for           Pennsylvania Power & Light                           Berwick, PA                 18603 (name and aodress of r-urchnaerj
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and aodress of r-urchnaerj
: 3. Location of installation           Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 I
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 iname and address) 5.700 PSI N/A I
iname and address) 5.700 PSI                             N/A                       2001
UV.f  
: 4. lype:                                    UV.f               .      . .. Lmar.spec
. --.. l (C R N I (y-s b uil t Lmar.spec og*
                                                                                . . .. I                og*  .  . --.. l                       (CRNI                    (y-s b uil t (drawing nr)                       (marl. spec. no.)
(drawing nr) 5 AMEM Code. Section III. Division 1:
                                                                                                    *'71                                                             N/A 5  AMEM Code. Section III. Division 1:                            .
(marl. spec. no.)
4'4 1,    V__________________f_______
4 '4
1' (addenda date)                    (class)                      (Code Case no.;
*'71 1'
N/A 1,
V__________________f_______
(edition)
(edition)
N/A              Revision            N/A            Date                  N/A
(addenda date)
(class)
(Code Case no.;
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA information of ASME (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required Section III 1971 Edition Summer 1971 addenda 1.50        Min. design thickness (in.)                1.36            Dia. ID (ft & in.)      N/A      . Length overall (ft& In.)          N/A
N/A Revision N/A Date N/A
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
: 8. Nom. Thickness (in.)
: 8. Nom. Thickness (in.)
Item of this report
1.50 Min. design thickness (in.)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Part or Appurtenance                             National Part or Appurtenance                          National                                           Serial Number                               Board No.
1.36 Dia. ID (ft & in.)
Serial Number                            Board No.                                                                                    In Numerical Order In Numerical Order (21).
N/A
(1)    HT:   54682     S/N   1                     N/A                                   (27)
. Length overall (ft& In.)
(2)    HT:   54682     S/N   2                     N/A
N/A
                                                                                                    .(28)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance National Serial Number Board No.
(3)    HT:   54682     S/N   3                     N/A                                     (29)
In Numerical Order (1)
(4)      HT:   54682     S/N   4                     N/A 130)
HT: 54682 S/N 1 N/A (2)
(5)     HT:   54682     S/N   5                     N/A                                     (31)
HT: 54682 S/N 2 N/A (3)
(6)      HT:   54682     SIN   6                     N/A (32)
HT: 54682 S/N 3 N/A (4)
(7). HT:   54682     S/N   8                   N/A (33)
HT: 54682 S/N 4 N/A (5)
(8)      HT:   54682     S/N   9                   N/A (34)
HT: 54682 S/N 5 N/A (6)
(9)
HT: 54682 SIN 6 N/A (7).
HT: 54682 S/N 8 N/A (8)
HT: 54682 S/N 9 N/A (9)
(10)
(11)
(12)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
: 10. Design pressure 1250 psi.
Temp.
575 Part or Appurtenance National Serial Number Board No.
In Numerical Order (21).
(27)
.(28)
(29) 130)
(31)
(32)
(33)
(34)
(35)
(35)
(10)                                                                                          (36)
(36)
(11)
(37)
(37)
(12)                                                                                          (38)
(38)
(39)
(39)
(14)                                                                                          (40)
(40)
(15)
(41)
(41)
(16)
(42)
(42)
(17)
(43)
(43)
(18)
(44)
(44)
(19)
(45)
(45)
(20)
(46)
(46)
(21)
(47)
(47)
(22)
(48)
(48)
(23)
(49)
(49)
(24)
(50)  
(50)
"*F. Hydro. test pressure N/A At temp. "F (when appi.cable)
(25)
"Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size s11 'A x 1, (2) Information In Items 2 and 3 on this Data Report Is Included an each sheet Is numbered and the number of sheets Is recorded at the top of this form.
                                                                                                        "*F.Hydro. test pressure                       N/A               At temp. "F
(12MH)
: 10. Design pressure                1250            psi. Temp.                575                                                      (when appi.cable) s11'A x 1, (2) Information In Items 2 and 3 on this Data Report Is "Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size of this form.
This $orm (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.
Included an each sheet Is numbered and the number of sheets Is recorded at the top Reiprnt (71 t)
Reiprnt (71 t)
(12MH)                               This $orm (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.
: 4. l ype:
2001 I


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Sedal Nos.           HT: 54682 S/N 1               through         SIN 6, 8 & 9 CERTIFICATION OF DESIGN N/A                        P.E. State          N/A            Reg. no.                        N/A Design specifications certified by (when applicable)
Certificate Holders' Sedal Nos.
P.E. State         N/A             Reg. no.                         N/A Design report* certified by N/A (when applicablel CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)
HT: 54682 S/N 1 through SIN 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)
Pilot Poppet conforms to the rules of construction of the ASME Code, Section III, Division 1.
N/A (when applicablel P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
NPT Certificate of Authorization No.                         N2607                         Expires                                   6-13-04          a Name            Atwood & Morrill Co., Inc.                     Signed      9o Date        1'l&#xfd;e                                                                                                                                    ,//
NPT Certificate of Authorization No.
(NPT Carohcat. Hakiew                                             (authoried repreenta=v) 6-13-04 CERTIFICATE OF INSPECTION Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure U 4- 0 1 9I 1e 1- ^
N2607 Pilot Poppet Expires Atwood & Morrill Co., Inc.
New York                   Arnd employea oy                                                     . .      .
(NPT Carohcat. Hakiew Signed 9o CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York Arnd employea oy Hartford, CT have inspected these Items described in this Data Report on  
                                                                                                                                    /            , and state that to the have inspected these Items described in this Data Report on                     .-
/
Hartford, CT                                                                                                                            Code, Section fabricated these parts or appurtenances   In accord   &#xfd;nc   %with   the ASME st of my knowledge and belief, the Certificate Holder has Division 1. Each part listed has been authorized for stamping on the date shown above.
, and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accord &#xfd;nc %with the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed the inspector   nor his employer   shall be liable in any manner   for any personal injury or property damage or in this Data Report. Furthermore, neither loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Signed                                                               Commissions         At)'J"?j1-V 7*9,             ,,0 Date                                                                                                                    (Nn d          Enoame*
Date (Nn d
                                                                                                                                        -in        s an st    o      adn.1 iAnse Upector)                                    -N*afl Bd. (mlec.Endersermnft*) *Rd Stte -r P-. and -1.
-in Enoame*
s an st o
.adn.1 Signed iAnse Upector)
Reg. no.
Reg. no.
N/A N/A Date 1'l&#xfd;e Name 6-13-04 a
6-13-04
,//
(authoried repreenta=v)
U 4- 0 1 9I 1e 1- ^
Commissions At)'J"?j1-V 7*9,  
,,0
-N*afl Bd. (mlec. Endersermnft*) *Rd Stte -r P-. and -1.


162AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
162AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                        PPL Susquehanna, LLC                                 Date                          04/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet                        of Address
: 3. Work Performed by PPL Susquehanna, LLC Name 76A9 Salem Blvd, Berwi Address Date Sheet Unit 04/25/2002 of ONE ECO 179460, PCWO 345125 Repair Organization P.O. No., Job No., etc.
: 2. Plant                Susquehanna Steam Electric Station                             Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                     ECO 179460, PCWO 345125 Address                                                          Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp None ck, PA 18603 Authorization No.
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name 76A9 Salem Blvd, Berwi ck, PA 18603                                 Authorization No.                             N/A Address Expiration Date                             N/A
N/A Expiration Date N/A
: 4. Identification of System                     REACTOR VESSEL AND AUXILIARIES SYSTEM 162A CLASS 2
: 4. Identification of System REACTOR VESSEL AND AUXILIARIES SYSTEM 162A CLASS 2
: 5. (a) Applicable Construction Code         ASME Section III   19   71   Edition,     Winter 72       Addenda,         N-411             Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19     89                 NO ADDENDA
: 5. (a) Applicable Construction Code ASME Section III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Name of                 Name of         Manufacturer         Board             Other             Year           Replaced, or         Stamped Component             Manufacturer           Serial No.         No.         Identification         Built         Replacement           (Yes or No)
: Edition, Winter 72
PIPE SUPPORT               BECHTEL                 N/A             N/A           SPDCB112-             1982           REPLACED                 NO H2003 PACIFIC               299NA                           SPDCB112 MECH SNUBBER               SCIFIC23599                               N/A                                 1981           REPLACED                 N/A SCIENTIFIC                                                 H2003 PIPE SUPPORT               BECHTEL                 N/A             N/A           SPDCB112-             1982           REPLACED                 NO H2014 PACIFIC                                             SPDCB112 MECH SNUBBER               SCIFIC                 13942             N/A             H201               1981           REPLACED                 N/A SCIENTIFIC                                                 H2014
: Addenda, N-411 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADDENDA
: 7. Description of Work                                       REMOVE SNUBBER / NO REPLACEMENT
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: 8. Tests Conducted:       Hydrostatic   E         Pneumatic     El     Nominal Operating Pressure           El Other   E       Pressure         N/A       psi     Test Temp.           N/A           &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/ in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
No.
Identification Built Replacement (Yes or No)
PIPE SUPPORT BECHTEL N/A N/A SPDCB112-1982 REPLACED NO H2003 PACIFIC 299NA SPDCB112 MECH SNUBBER SCIFIC23599 N/A 1981 REPLACED N/A SCIENTIFIC H2003 PIPE SUPPORT BECHTEL N/A N/A SPDCB112-1982 REPLACED NO H2014 PACIFIC SPDCB112 MECH SNUBBER SCIFIC 13942 N/A H201 1981 REPLACED N/A SCIENTIFIC H2014
: 7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
: 8. Tests Conducted:
Hydrostatic E
Pneumatic El Nominal Operating Pressure El Other E Pressure N/A psi Test Temp.
N/A  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/ in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this             REPLACEMENT                 conforms to the rules of the ASME Code, Section XI.                                                                     repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                                   N/A Signed                 --  /A,, -//,a-                                       Date                       /2.-               ,20 2.-0._    __-L-Owner rowners Desine   Tide   Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                     and employed by               FACTORY MUTUAL INSURANCE CO.                                         of JOHNSTON, RHODE ISLAND                                                                     have nspected the comiginents described in this Owner's Report during the period                 -0                 I             to       2-      -      /'3-   n:<-         _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
: 9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed  
/A,, -//,a-Date 2.-0._
/2.-  
,20
__-L-Owner rowners Desine Tide Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have nspected the comiginents described in this Owner's Report during the period  
-0 2-I to  
/'3-n:<-
_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___________________C                                     mmissions NIF7c/80                   A.NB:&#xfd;'.14.S           04 Z W4 lnspectorifSignature                                                 National Board, State, Province, and Endorsements Date J1EA'       107               20O2.
___________________C mmissions NIF7c/80 A.NB:&#xfd;'.14.S 04 Z W4 lnspectorifSignature National Board, State, Province, and Endorsements Date J1EA' 107 20O2.


164AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
164AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                        PPL Susquehanna, LLC                                   Date                          04/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet            1          of                      1 Address
: 3. Work Performed by PPL Susquehanna, LLC Name Unit ONE ECO 179459, PCWO 345105 Repair Orgarization P.O. No., Job No., etc.
: 2. Plant                Susquehanna Steam Electric Station                             Unit                              ONE Name 769 Salem Blvd, Berwick, PA 18603                                     ECO 179459, PCWO 345105 Address                                                        Repair Orgarization P.O. No., Job No., etc.
Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name 769 Salem Blvd, Berwick, PA 18603                                   Authorization No.                           N/A Address Expiration Date                             N/A
Expiration Date
: 4. Identification of System                             REACTOR RECIRCULATION SYSTEM 164A CLASS I
: 4. Identification of System REACTOR RECIRCULATION SYSTEM 164A CLASS I
: 5. (a) Applicable Construction Code         ASME Section III   19   71   Edition,     Winter 72       Addenda,         N-411             Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89                 NO ADDENDA
: 5. (a) Applicable Construction Code ASME Section III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                              Repaired,            Code Manufacturer        Board              Other            Year          Replaced, or          Stamped Name of                  Name of Serial No.        No.          Identification        Built        Replacement            (Yes or Component              Manufacturer No)
: Edition, Winter 72
PIPE SUPPORT                BECHTEL                N/A            N/A            SPDCA120-            1982          REPLACED                NO H2006 PACIFIC              23573            N/A            SPDCA120-            1981          REPLACED                N/A MECH SNUBBER                SCIENTIFIC                                                H2006
: Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
: 7. Description of Work                                       REMOVE SNUBBER / NO REPLACEMENT
: 6. Identification of Components Repaired or Replaced and Replacement Components Code Case
: 8. Tests Conducted:       Hydrostatic     F       Pneumatic     F       Nominal Operating Pressure           1:]
: 7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
Other   E       Pressure         N/A     psi     Test Temp.           N/A         &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 8. Tests Conducted:
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
Hydrostatic F
Pneumatic F
Nominal Operating Pressure 1:]
Other E Pressure N/A psi Test Temp.
N/A  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant Date Sheet 04/25/2002 1
of 1
N/A N/A ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
PIPE SUPPORT BECHTEL N/A N/A SPDCA120-1982 REPLACED NO H2006 PACIFIC 23573 N/A SPDCA120-1981 REPLACED N/A MECH SNUBBER SCIENTIFIC H2006 (12/82)


II-FORM NIS-2 (Back)
II-FORM NIS-2 (Back)
: 9. Remarks         Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda 1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 DiDina per ASME 111,1974 Edition, Summer 1975 Addenda, paragraph NB-3630.
: 9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda 1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 DiDina per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this             REPLACEMENT               conforms to the rules of the ASME Code, Section Xl.                                                                     repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                                     N/A Signed                             ,                                            Date           -      &#xfd;   / 2--,             20 ) L-Sid Ownr     io Dsi wer's       . Title   Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by               FACTORY MUTUAL INSURANCE CO.                                         of JOHNSTON, RHODE ISLAND                                                                       have inspected the co*ponents described in this Owner's Report during the period           I - Z         - /) 0 / 1               to            ---        -      ."        ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed Date  
&#xfd;  
/ 2--,
20 ) L-Sid Ownr io wer's Dsi
. Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND have inspected the co*ponents described in this Owner's Report during the period I  
- Z  
- /)  
/
to 0
1  
,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____ __      _  _      _    _  _            ommissions NZ? 77 90AN                                   NS       J P?  Z-0 4 Inspector'VIignature                                               National Board, State, Province, and Endorsements Date       "TvtvL17                  2002,
ommissions NZ? 77 90AN P?
NS J
Z-0 4 Inspector'VIignature National Board, State, Province, and Endorsements Date "TvtvL 17
: 2002,


164AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 769 Salem Blvd, Berwick, PA 18603
164AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 769 Salem Blvd, Berwick, PA 18603 Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603
: 1. Owner                                                                              Date                          04/25/2002 Name Two North Ninth St., Allentown, PA 18101                               Sheet            1          of                      1 Address
: 3. Work Performed by Address PPL Susquehanna, LLC Name ECO 179459, PCWO 345109 Repair Organization P.O. No., Job No., etc.
: 2. Plant                Susquehanna Steam Electric Station                             Unit                                ONE Name 769 Salem Blvd, Berwick, PA 18603                                     ECO 179459, PCWO 345109 Address                                                        Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.
: 3. Work Performed by                    PPL Susquehanna, LLC                          Type Code Symbol Stamp                           None Name 769 Salem Blvd, Berwick, PA 18603                                   Authorization No.                             N/A Address Expiration Date                             N/A
Expiration Date
: 4. Identification of System                             REACTOR RECIRCULATION SYSTEM 164A CLASS II
: 4. Identification of System REACTOR RECIRCULATION SYSTEM 164A CLASS II
: 5. (a) Applicable Construction Code           ASME Section III   19 71   Edition,     Winter 72       Addenda,         N-411             Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19     89                 NO ADDENDA
: 5. (a) Applicable Construction Code ASME Section III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                              Repaired,            Code Name of                Name of            Manufacturer      Board            Other              Year          Replaced, or          Stamped Component              Manufacturer            Serial No.        No.          Identification        Built          Replacement            (Yes No)or PIPE SUPPORT                BECHTEL                  N/A            N/A          SPDCB1 12-            1982          REPLACED                NO H2094 MECH SNUBBER                  PACIFIC                                            SPDCB112-              1981          REPLACED                N/A SCIENTIFIC              22861            N/A              H2094
: Edition, Winter 72
: 7. Description of Work                                         REMOVE SNUBBER / NO REPLACEMENT
: Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
: 8. Tests Conducted:       Hydrostatic     E         Pneumatic     0     Nominal Operating Pressure           E Other     E         Pressure         N/A     psi     Test Temp.           N/A           &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 6. Identification of Components Repaired or Replaced and Replacement Components Code Case
(12/82)                          This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
: 8. Tests Conducted:
Hydrostatic E Pneumatic 0
Nominal Operating Pressure E
Other E Pressure N/A psi Test Temp.
N/A  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant 04/25/2002 Date Sheet Unit 1
of 1
ONE N/A N/A ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
PIPE SUPPORT BECHTEL N/A N/A SPDCB1 12-1982 REPLACED NO H2094 MECH SNUBBER PACIFIC SPDCB112-1981 REPLACED N/A SCIENTIFIC 22861 N/A H2094 (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Ad. Code Case N-411 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this               REPLACEMENT                 conforms to the rules of the ASME Code, Section Xl.                                                                       repair or replacement Type Code Symbol Stamp                                                                     N/A Certificate of Authorization No.                     N/A                     Expiration                                   N/A Signed                                                                           Date                         /2Z-2-            ,20 UL Owtr or, Owner's           oTite Siiv. - Site Modifications Group 1Th CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by               FACTORY MUTUAL INSURANCE CO.                                       of JOHNSTON, RHODE ISLAND                                                   -                  hav Jnsped the components described in this Owner's Report during the period                   --  ?* -. (21     7              to           -V->--             t.S       , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
: 9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Ad. Code Case N-411 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Signed Date 2-
/2Z-  
,20 UL Owtr or Owner's oTite Siiv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND hav Jnsped the components described in this Owner's Report during the period 7
?* -. (21 to  
-V ->--
t.S  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____________  _____________Commissions                             N8879*O8 A,...       & ,          /:
_____________Commissions N8879*O8 A,...  
1S       PA ZZO nspe         Signature                                               National Board, State, Province, and Endorsements Date   Jlui 17                         2002.
/:
1S PA ZZO nspe Signature National Board, State, Province, and Endorsements Date Jlui 17 2002.
1Th


164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 1. Owner                        PPL Susquehanna, LLC                                   Date                          05/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet            1          of Address
: 3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, P Address Date Sheet 05/25/2002 1
: 2. Plant                Susquehanna Steam Electric Station                              Unit                               ONE Name MODIFICATIONS: 179459, 391402, & 391467 769 Salem Blvd, Berwick, PA 18603                                      WORK ORDERS: 345105, 391433, & 391471 Address                                                          Repair Organization P.O. No. Job No., etc.
of Unit ONE MODIFICATIONS: 179459, 391402, & 391467 WORK ORDERS: 345105, 391433, & 391471 Repair Organization P.O. No. Job No., etc.
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name 769 Salem Blvd, Berwick, P A 18603                                   Authorization No.                             I/A N_
Type Code Symbol Stamp None A 18603 Authorization No.
Address Expiration Date                             N /A
N_
: 4. Identification of System                             REACTI OR RECIRCULA I ION SYSTEM 164D CLASS 2
Expiration Date N
: 5. (a) Applicable Construction Code         ASME Section III     19 71   Edition,     Winter 72       Addenda,         N-411             Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19       89                   NO ADDENDA
I/A
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,           Code Name of           Manufacturer       Board               Other             Year           Replaced, or         Stamped Name of Manufacturer           Serial No.       No.           Identification         Built         Replacement           (Yes or Component No)
/A
: 1) PIPE SUPPORT                 BECHTEL                 N/A           N/A           SPDCB106-             1982           REPLACED               NO H2022 PACIFIC                                             SPDCB106
: 4. Identification of System REACT I OR RECIRCULA I ION SYSTEM 164D CLASS 2
: 2) MECH SNUBBER               SCIENTIFIC               24388           N/A             H2022               1982           REPLACED               N/A
: 5. (a) Applicable Construction Code ASME Section III 19 71
: 3) SMALL PIPE                   BECHTEL                 N/A           N/A           SPDCB106-6             1982           REPLACED               YES
: Edition, Winter 72
: 4)   SMALL PIPE                     PPL                   N/A           N/A           SPDCB106-6             2002         REPLACEMENT               NO
: Addenda, N-411 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADDENDA
: 5) SMALL PIPE                   BECHTEL                 N/A           N/A           SPDCB108-3             1982           REPLACED               YES
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: 6)   SMALL PIPE                     PPL                   N/A           N/A           SPDCB108-3             2002         REPLACEMENT               NO
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
: 7) SMALL PIPE                   BECHTEL                   N/A           N/A           SPDCB121-4             1982           REPLACED               YES
No.
: 7. Description of Work     Permanent removal of snubber support, and replaced piping do to socket weld UT exam failures.
Identification Built Replacement (Yes or No)
: 8. Tests Conducted:      Hydrostatic     F]       Pneumatic     E-     Nominal Operating Pressure             E-Other    E        Pressure          N/A     psi     Test Temp.           N/A           'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 1) PIPE SUPPORT BECHTEL N/A N/A SPDCB106-1982 REPLACED NO H2022 PACIFIC SPDCB106
(12/82)                        This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 2) MECH SNUBBER SCIENTIFIC 24388 N/A H2022 1982 REPLACED N/A
: 3) SMALL PIPE BECHTEL N/A N/A SPDCB106-6 1982 REPLACED YES
: 4)
SMALL PIPE PPL N/A N/A SPDCB106-6 2002 REPLACEMENT NO
: 5) SMALL PIPE BECHTEL N/A N/A SPDCB108-3 1982 REPLACED YES
: 6)
SMALL PIPE PPL N/A N/A SPDCB108-3 2002 REPLACEMENT NO
: 7) SMALL PIPE BECHTEL N/A N/A SPDCB121-4 1982 REPLACED YES
: 7. Description of Work
: 8. Tests Conducted:
Permanent removal of snubber support, and replaced piping do to socket weld UT exam failures.
Hydrostatic F]
Pneumatic Other E Pressure E-Nominal Operating Pressure N/A psi Test Temp.
N/A  
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant E-(12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this             REPLACEMENT             conforms to the rules of the ASME Code, Section XI.                                                                     repair or replacement Type Code Symbol Stamp                                                                   N/A Certificate of Authorization No.                   N/A                     Expiration                                 N/A Signed                                                                         Date                                       ,2001 O Owner'sOsig/4e, Title "upv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by             FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON, RHODE ISLAND                                               -have                         inspected the gomponents described in this Owner's Report during the period               -  - () -- U I           _        to     "* --      7-
: 9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI.
                                                                                                                -. 0--               , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
N/A Expiration N/A Signed Date  
    &#xa3;,4)A, &#xfd;         '/?* L__*,1/4?                                   Commissions Ve'7280 A &.r.                         AIS     PA ZZO4 Inspector',ig nature                                               National Board, State, Province, and Endorsements Date       Up       Z"               2.2-2 0
,2001 O Owner's Osig/4e, Title "upv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON, RHODE ISLAND  
-have inspected the gomponents described in this Owner's Report during the period U
- () --
I to  
-.7- 0--  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.  
&#xa3;,4)A, &#xfd;  
'/?* L__*,1/4?
Commissions Ve'7280 A &.r.
AIS PA ZZO4 Inspector',ig nature National Board, State, Province, and Endorsements Date Up Z"
2 0 2.2-


164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 05/25/2002 2
: 1. Owner                        PPL Susquehanna, LLC                                 Date                           05/25/2002 Name 769 Salem Blvd, Berwick, PA 18603                                   Sheet            2            of                    2 Address
of 2
: 2. Plant                Susquehanna Steam Electric Station                            Unit                                ONE Name MODIFICATIONS: 179459, 391402, & 391467 769 Salem Blvd, Berwick, PA 18603                                    WORK ORDERS: 345105, 391433, & 391471 Address                                                          Repair Organization P.O. No., Job No, etc.
ONE 769 Salem Blvd, Berwick, PA 18603 Address
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                             None Name 769 Salem Blvd, Berwick, PA 18603                                 Authorization No.                             N/A Address Expiration Date                             N/A
: 3. Work Performed by PPL Susquehanna, LLC Name MODIFICATIONS: 179459, 391402, & 391467 WORK ORDERS: 345105, 391433, & 391471 Repair Organization P.O. No., Job No, etc.
Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.
Expiration Date
: 4. Indentification of System
: 4. Indentification of System
: 5. (a) Applicable Construction Code                 III         19   71   Edition,   thru W'72         Addenda,        N-411              Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19     89
: 5. (a) Applicable Construction Code III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,           Code Name of                 Name of           Manufacturer         Board             Other             Year           Replaced, or         Stamped Component             Manufacturer           Serial No.         No.         Identification         Built         Replacement           (Yes or No)
: Edition, thru W'72 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 8)   SMALL PIPE                   PPL                   N/A             N/A         SPDCB121-4             2002       REPLACEMENT               NO
: 6. Identification of Components Repaired or Replaced and Replacement Components
: Addenda, N-411 Code Case
: 1. Owner
: 2. Plant N/A N/A ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
: 8)
SMALL PIPE PPL N/A N/A SPDCB121-4 2002 REPLACEMENT NO


183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
: 1. Owner                       PPL Susquehanna, LLC                                   Date                          4/25/2002 Name Two North Ninth St., Allentown, PA 18101                               Sheet            1          of                      3 Address
: 1. Owner
: 2. Plant              Susquehanna Steam Electric Station                              Unit                               One Name PCWO 345898, 345911, 345920, 345927 769 Salem Blvd, Berwick, PA 18603                                      DCP 316333, 316334, 316335, 316336 Address                                                          Repair Organization P.O. No., Job No.. etc.
: 2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                                Authorization No.                           N/A Address Expiration Date                             N/A
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
: 4. Identification of System                                              183A, Main Steam; Class 1
: 4. Identification of System Date Sheet Unit 4/25/2002 1
: 5. (a) Applicable Construction Code                 III         19   71     Edition,     thru S' 71     Addenda,          1535-2            Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89
of 3
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                Repaired,             Code Name of                Name of            Manufacturer        Board              Other              Year          Replaced, or          Stamped Component              Manufacturer          Serial No.          No.          Identification        Built        Replacement            (Yes or No) 26" MSIV            Atwood & Morrill            5-221            NA          HV141FO28A            1974            Replaced              Yes 26" MSIV            Atwood & Morrill            5-221            NA          HV141F028A            1974            Repaired              Yes Super Bolts ( torque      Atwood & Morrill            N/A            NA          HV141F028A            2001          Replacement              No nut assemblies)
One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.O. No., Job No.. etc.
Poppet            Atwood & Morrill        245951-3          NA            HV141F028A            2001          Replacement              Yes Bonnet Cover          Atwood & Morrill        H3391-1            NA            HV141F028A            2001          Replacement              Yes Pilot Poppet        Atwood & Morrill          54682-1          NA            HV141FO28A            2001          Replacement              Yes Body/Bonnet Stud        Atwood & Morrill              NA            NA            HV141FO28A            2001          Replacement              No
Type Code Symbol Stamp None Authorization No.
: 7. Description of Work                             Improve seating characteritics and maintainability of MSIVs
N/A Expiration Date N/A 183A, Main Steam; Class 1
: 8. Tiests Conducted:     Hydrostatic     El       Pneumatic     E]     Nominal Operating Pressure           nX         SE-100-002/SE-000-017 Other n           Pressure           975     psi     Test Temp.             521         &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/22 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 5. (a) Applicable Construction Code III 19 71
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components
: Addenda, 1535-2 Code Case
: 7. Description of Work
: 8. Ti Improve seating characteritics and maintainability of MSIVs ests Conducted:
Hydrostatic El Pneumatic E]
Nominal Operating Pressure nX SE-100-002/SE-000-017 Other n
Pressure 975 psi Test Temp.
521  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/22 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 5-221 NA HV141FO28A 1974 Replaced Yes 26" MSIV Atwood & Morrill 5-221 NA HV141F028A 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028A 2001 Replacement No nut assemblies)
Poppet Atwood & Morrill 245951-3 NA HV141F028A 2001 Replacement Yes Bonnet Cover Atwood & Morrill H3391-1 NA HV141F028A 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-1 NA HV141FO28A 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28A 2001 Replacement No (12/82)


1t-~.
1t -~
FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.
: 9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.
National Board Forms NR-1 and ASME Forms N-2 are attached.
National Board Forms NR-1 and ASME Forms N-2 are attached.
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                 Repair/Replacement       conforms to the rules of the ASME Code, Section XI.                                                                         repair or repiacement Type Code Symbol Stamp                                                                       N/A Certificate of Authorization No.                       N/A                     Expiration                                 N/A Signed                                                                             Date                           26
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair/Replacement conforms to the rules of the ASME Code, Section XI.
                                                                                                                        -20               02-er w     gnee. TitUe     Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                           and employed by               FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON, RHODE ISLAND                                                                         have inspected the components described in this Owner's Report during the perod             Z - z Is- o       .                      to         (.o -. 4 - ) Z         _      , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.
repair or repiacement Type Code Symbol Stamp N/A Certificate of Authorization No.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
N/A Expiration N/A Signed Date 26  
.&XZ1       4 S     .I
-20 02-er w gnee. TitUe Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
                    -/-                     =--'J=*#.W               Commissions NI?798OA                         T.Z_..,NS     PA0 Z-0.4 Inspector's S/   ature                                                 National Board, Slate, Province, and Endorsements Date     u Nh tC     Z'               200_
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the perod Z - z Is-o to
(.o -.
4 - ) Z  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.  
.&XZ1 4 S  
.I  
-/-  
=--'J=*#.W Commissions NI?798OA T.Z_..,NS PA0 Z-0.4 Inspector's S/
ature National Board, Slate, Province, and Endorsements Date u Nh tC Z'
200_


183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner                         PPL Susquehanna, LLC                                 Date                            4/25/2002 Namre Two North Ninth St., Allentown, PA 18101                               Sheet            2            of                      3 Address
183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner PPL Susquehanna, LLC Namre Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Namre 769 Salem Blvd, Berwick, PA 18603 Address
: 2. Plant                Susquehanna Steam Electric Station                            Unit                               One Namre PCWO 345898, 345911, 345920, 345927 769 Salem Blvd, Berwick, PA 18603                                      DCP 316333, 316334, 316335, 316336 Address                                                          Repair Organization P.0- No., Job No., etc.
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                              Authorization No.                             N/A Address Expiration Date                             N/A
: 4. Identification of System Date Sheet Unit 4/25/2002 2
: 4. Identification of System                                              183A, Main Steam; Class 1
of 3
: 5. (a) Applicable Construction Code                 i11         19   71     Edition,   thru S' 71       Addenda,        1535-2              Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19     89
One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.0- No., Job No., etc.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                              Repaired,             Code Board                                              Replaced, or          Stamped Name of                 Name of           Manufacturer                           Other            Year                                  (Yes or Manufacturer           Serial No.         No.         Identification         Built         Replacement Component                                                                                                                                    No) 26" MSIV           Atwood & Morrill           6-221             NA         HV141FO28B             1974             Replaced               Yes 26" MSIV           Atwood & Morrill           6-221             NA         HV141FO28B             1974             Repaired               Yes Super Bolts ( torque     Atwood & Morrill             N/A             NA         HV141F028B             2001           Replacement             No nut assemblies)
Type Code Symbol Stamp None Authorization No.
Poppet                 Welding             245951-1             NA         HV141FO28B             2001           Replacement             Yes Services Inc.
N/A Expiration Date N/A 183A, Main Steam; Class 1
Bonnet Cover         Atwood & Morrill         H3391-4             NA         HV141FO28B             2001           Replacement             Yes Pilot Poppet         Atwood & Morrill         54682-4             NA         HV141F028B             2001           Replacement             Yes Body/Bonnet Stud         Atwood & Morrill             NA             NA           HV141FO28B             2001           Replacement             No 26" MSIV           Atwood & Morrill           7-221             NA           HV141F028C             1974             Replaced               Yes 26" MSIV           Atwood & Morrill           7-221             NA           HV141F028C             1974             Repaired               Yes Super Bolts ( torque     Atwood & Morrill           N/A             NA           HV141 F028C           2001           Replacement             No nut assemblies)
: 5. (a) Applicable Construction Code i11 19 71
Poppet               Welding             245951-2           NA           HV141 F028C           2001           Replacement             Yes Services Inc.
: Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components
: Addenda, 1535-2 Name of Component Name of Manufacturer Manufacturer Serial No.
National Board No.
Other Identification Year Built
: Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No) 26" MSIV Atwood & Morrill 6-221 NA HV141FO28B 1974 Replaced Yes 26" MSIV Atwood & Morrill 6-221 NA HV141FO28B 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028B 2001 Replacement No nut assemblies)
Poppet Welding 245951-1 NA HV141FO28B 2001 Replacement Yes Services Inc.
Bonnet Cover Atwood & Morrill H3391-4 NA HV141FO28B 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-4 NA HV141F028B 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28B 2001 Replacement No 26" MSIV Atwood & Morrill 7-221 NA HV141F028C 1974 Replaced Yes 26" MSIV Atwood & Morrill 7-221 NA HV141F028C 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141 F028C 2001 Replacement No nut assemblies)
Poppet Welding 245951-2 NA HV141 F028C 2001 Replacement Yes Services Inc.
: 2. Plant Code Case


183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner                         PPL Susquehanna, LLC                                 Date                            4/25/2002 Name Two North Ninth St., Allentown, PA 18101                               Sheet            3          of                      3 Address
183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101
: 2. Plant               Susquehanna Steam Electric Station                             Unit                               One Name PCWO 345898, 345911, 345920, 345927 769 Salem Blvd, Berwick, PA 18603                                    DCP 316333, 316334, 316335, 316336 Address                                                          Repair Organization P.O. No., Job No.. etc.
: 2. Plant Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                              Authorization No.                             N/A Address Expiration Date                             N/A
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date 4/25/2002 Sheet 3
: 4. Identification of System                                             183A, Main Steam; Class 1
of 3
: 5. (a) Applicable Construction Code                 III         19   71   Edition,     thru S' 71       Addenda,         1535-2             Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19     89
Unit One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.O. No., Job No.. etc.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Name of                 Name of           Manufacturer         Board             Other             Year           Replaced, or         Stamped Component             Manufacturer           Serial No.         No.         Identification         Built         Replacement           (Yes or No)
Type Code Symbol Stamp None Authorization No.
Bonnet Cover         Atwood & Morrill           H3391-6           NA         HV141FO28C             2001           Replacement             Yes Pilot Poppet         Atwood & Morrill           54682-6         NA         HV141FO28C             2001         Replacement               Yes Body/Bonnet Stud         Atwood & Morrill             NA             NA         HV141F028C             2001         Replacement               No 26" MSIV           Atwood & Morrill             8-221           NA         HV141FO28D             1974             Replaced               Yes 26" MSIV           Atwood & Morrill             8-221           NA         HV141FO28D             1974             Repaired               Yes Super Bolts ( torque     Atwood & Morrill             N/A           NA         HV141F028D             2001         Replacement               No nut assemblies)
N/A Expiration Date N/A
Poppet           Atwood & Morrill         245951-6           NA         HV141F028D             2001         Replacement               Yes Bonnet Cover           Atwood & Morrill         H3391-2           NA         HV141FO28D             2001         Replacement               Yes Pilot Poppet         Atwood & Morrill         54682-2           NA         HV141FO28D             2001         Replacement               Yes Body/Bonnet Stud         Atwood & Morrill             NA             NA         HV141FO28D             2001         Replacement               No
: 4. Identification of System 183A, Main Steam; Class 1
: 5. (a) Applicable Construction Code III 19 71
: Edition, thru S' 71
: Addenda, 1535-2 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Bonnet Cover Atwood & Morrill H3391-6 NA HV141FO28C 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-6 NA HV141FO28C 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141F028C 2001 Replacement No 26" MSIV Atwood & Morrill 8-221 NA HV141FO28D 1974 Replaced Yes 26" MSIV Atwood & Morrill 8-221 NA HV141FO28D 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028D 2001 Replacement No nut assemblies)
Poppet Atwood & Morrill 245951-6 NA HV141F028D 2001 Replacement Yes Bonnet Cover Atwood & Morrill H3391-2 NA HV141FO28D 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-2 NA HV141FO28D 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28D 2001 Replacement No


FORM NR-1           REPORT OF REPAIR [&#xfd;                   MODIFICATION 0]                 OR REPLACEMENT               []
FORM NR-1 REPORT OF REPAIR [&#xfd; MODIFICATION 0]
OR REPLACEMENT []
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 1. Work performed by         Continental Field Systems,                               Inc                               3218 (name of NR certificate holder)                                       (P.O. no., job no., etc.)
: 1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
23 Westgate Blvd.                 Savannah,           GA 31405 (address)
(P.O. no., job no., etc.)
: 2. Owner           PPL LLC (name) 2 North Ninth Street,                     Allentown,               PA 18101 (address)
23 Westgate Blvd.
: 3. Name, address and identification of nuclear power plant                   Susquehanna Steam Electric 5 Miles North of Berwick, PA                                                   Salem Twp, PA
: Savannah, GA 31405 (address)
: 4. System       1-83           HV141FO28A                             Main Steam
: 2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                           See Attached Identification                                                       Construction Code                         Activity Type of     Mfg.         Mfg. Nat'l Bd. Jurisd.           Other         Year       Name/         Edition/       Code         Code         Repair/
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA Salem Twp, PA
No     Item     Name     Serial No. No.       No.                     Built       Section/     Addenda     Case(s)       Class         Mod/
: 4. System 1-83 HV141FO28A Main Steam
Division                                               Replace 2
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
9 10 11 12_
9 10 11 12_
: 5. b: Items Installed During Replacement Activities                     . e Attache         d Identification                                                             Construction Code Type of     Installed or. Mfg.       Mfg         Nat'l Bd.         Jurisd     Other       Year     Name/       Edition/         Code Code Item         Replaced     Name Serial No.           No.             No                 Built     Section/   Addenda Case(s) Class 5a Item No.                                                                               Division
: 5. b: Items Installed During Replacement Activities e Attache d Identification Construction Code Type of Installed or.
: 6. ASME Code Section XI applicable for inservice inspection:                   1989                       N/A                           N/A (edition)                 (addenda)                 (Code Cases(s))
Mfg.
: 7. ASME Code Section XI used for repairs, modifications, or replacements:                       19.8&9               NIA                 N4 A/
Mfg Nat'l Bd.
(edition)       (addenda)             (Code Cases(s))
Jurisd Other Year Name/
: 8. Construction Code used for repairs, modifications, or replacements:                       1971               S 71                     N/A (edition)         (addenda)             (Code Cases(s))
Edition/
: 9. Designresponsibilities:           Atwood & Mnrril fn
Code Code Item Replaced Name Serial No.
: 10. Tests conducted: hydrostatic [E pneumatic El design pressure                     El     pressurejNLA. psi Code Case(s)
No.
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                         Rev. 8
No Built Section/
: 11. Description of v *ork:    See Attached Se (e.pDescniptionlofsoseork:
Addenda Case(s) Class 5a Item No.
Ata (use       h didentified additional sheet(s) or sketch(es) of property                                          is acceptable) 12.Remarks:     See attached manufacturer's                               data report CERTIFICATE OF COMPUANCE I,   David McCathie                 certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
Division
National Board Certificate of Authorization No.             NR-R6                   to use the "NR" stamp expires 5/2i                         2001 NR Certificate Holder       Continental Field Systems. Inc Date 641&       9002       Signed __Iliin1)                     .I             0                     U         tv (',-inirrl MnlnnaPr (authorized representative)                              *-        - - (title.) . .  . ..
: 6. ASME Code Section XI applicable for inservice inspection:
CERTIFICATE OF INSPECTION I, WIL.IAM       'i22' 60* i r_ holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of                               Yt. V4,M/4
1989 N/A N/A (edition)
                                                                                                    ?NN                            and employed by h-Actvgy Mu           9L r   I4XyR. #tyCE- Commm'                                     of CFoH,'IroAI                 IZ E                           have inspected the repair, modification or replacement described in this report on 4
(addenda)
* 1                             ,    00Z.         and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
(Code Cases(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:
19.8&9 NIA N4 A/
(edition)
(addenda)
(Code Cases(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 S 71 N/A (edition)
(addenda)
(Code Cases(s))
: 9. Designresponsibilities:
Atwood & Mnrril fn
: 10. Tests conducted: hydrostatic [E pneumatic El design pressure El pressurejNLA. psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
 
(e.pDescniptionlofsoseork:
Se Ata h d
(use of property identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks: See attached manufacturer's data report V
CERTIFICATE OF COMPUANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-R6 to use the "NR" stamp expires 5/2i 2001 NR Certificate Holder Continental Field Systems.
Inc Date 641&
9002 Signed __Iliin1)  
.I 0
U tv (',-inirrl MnlnnaPr CERTIFICATE OF INSPECTION I, WIL.IAM 2'  
'i2 60* r_
i holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of  
?NN Yt. V4,M/4 and employed by h-Actvgy Mu 9L r
I4XyR. #tyCE-Commm' of CFoH,'IroAI IZ E have inspected the repair, modification or replacement described in this report on 4
* 1 00Z.
and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
z+.ZA LUOZ Signed 4                   4 DateTNek                                              .a?,'7?
DateTNek z+.ZA LUOZ Signed 4
V 07.iZ                         CommissionsN8R7             OA3A.",/1Nr PA 2..04 (inspector),1                       (National Board (ind. endorsements), jurisdiction, and no.)
4.a?,'7?
V
V 07.iZ CommissionsN8R7 OA3 A.",/1Nr PA 2..04 (inspector),1 (National Board (ind. endorsements), jurisdiction, and no.)
See Attached
*ork:
: 11. Description of v (title.)..
(authorized representative)


Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.                             Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A Items Which Required Repair, Modification, or Replacement Activities Identification Items Installed During Replacement Activities Identification Item         Installed/   MFG.       Mfg. Serial   Nat'l     Jurisd. No. Other Year Built Name/     Edition/   Code   Code Replaced     Name         No.     Bd. No.                                   Section/   Addenda   Case(s) Class Division Poppet       Replaced     A&M           3         N/A           N/A       N/A     2001     III NB 71 Ed. S71 A N/A       I Bonnet       Replaced     A&M             I       N/A           N/A       N/A     2001     III NB 71 Ed. S71 A N/A       I Pilot Poppet     Replaced     A&M             I       N/A           N/A       N/A     2001     III NB 71 Ed. S71 A N/A       I Super Nuts     Replaced     A&M       NU-01017     N/A           N/A       N/A     2002     III NB 71 Ed. S71 A N/A       I I of 2
Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A Items Which Required Repair, Modification, or Replacement Activities Identification Items Installed During Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced A&M 3
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Bonnet Replaced A&M I
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Pilot Poppet Replaced A&M I
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I
I of 2


Form NR-1 Attachment                                         Report cff Repair / Replacement C Worked Performed by Continental Field Systems, Inc.
Form NR-1 Attachment Report c Worked Performed by Continental Field Systems, Inc.
23 Westgate Blvd., Savannah, Georgia 31405 Job Number 3218 Owner: PPL LLC 2 North 9h St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A
C 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A
: 6. ASME Code Section XI applicable for inservice inspection: 1989                   N/A            NI A (edition)          (addenda)      (C ode Case(s))
: 6. ASME Code Section XI applicable for inservice inspection: 1989 (edition)
: 7. ASME Code Section X] used for repairs, modifications, or replacements:1989               N/A              N/A (edition)        (addenda)        (Code Case(s))
: 7. ASME Code Section X] used for repairs, modifications, or replacements:1989 (edition)
: 8. Construction Code used for repairs, modifications, or replacements: 1971                 Summer 71       I (edition)         (addenda)       Code Case
: 8. Construction Code used for repairs, modifications, or replacements: 1971 (edition) ff Repair / Replacement Job Number 3218 N/A NI (addenda)
(C N/A (addenda)
Summer 71 (addenda)
A ode Case(s))
N/A (Code Case(s))
I Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
2 of 2
2 of 2


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Pg. 1 of 2 Not to Exceed One Day's Production
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by                   Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 2. Manufactured for         Pennsylvania Power & Light                           Berwick, PA 18603 (iname and address of Purchaserl
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (iname and address of Purchaserl
: 3. Location of installation           Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
SA 105 GR II                        81,600 PSI                                    N/A                        2001
: 4. Type:  
: 4. Type:             *32162-409-D Rev. 1                                                                                                                                         (year built (mati. spec. no.)                 (tensile strength)                           (CRN)
*32162-409-D Rev. 1 SA 105 GR II 81,600 PSI N/A 2001 (dra'wig no.)
(dra'wig no.)
(mati. spec. no.)
1971                            S71                                1                                  N/A
(tensile strength)
(CRN)
(year built
: 5. ASME Code, Section III, Division 1:
: 5. ASME Code, Section III, Division 1:
(edition)                 (addenda datas)C0                                                           " so no.--,
1971 S71 1
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                               N/A             Revision                 N/A               Date                   N/A (no.)
N/A (edition)
: 7. Remarks:           Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA the required information of ASME (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets Section III 1971 Edition summer 1971 addenda 5.312            Min. design thickness (in.)          5.094          Dia. I1 (ft & in.)          N/A        Length overall (ft& In.)            N/A
(addenda datas)C0 so no.--,
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
N/A Revision N/A Date N/A (no.)
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
: 8. Nom. Thickness (in.)
: 8. Nom. Thickness (in.)
report:
5.312 Min. design thickness (in.)
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this National                                  Part or Appurtenance                                 National Part or Appurtenance                                                                                                                             Board No.
5.094 Dia. I1 (ft & in.)
Board No.                                       Serial Number Serial Number In Numerical Order                                                                              nI  umgll;leu        1 N/A                              (26)
N/A Length overall (ft& In.)
      -(1)       HT: H3391 S/N 1                                                                   (27)
N/A
(2)      HT: H3391 S/N 2                                 N/A                              ,(28)
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
(3)      HT: H3391 S/N 3                                 N/A                              (29)
Part or Appurtenance National Part or Appurtenance National Serial Number Board No.
(4)                                                                                        (30)
Serial Number Board No.
(5)                                                                                      (31)
-(1)
(6)                                                                                       (32)                                        +
HT: H3391 S/N 1 (2)
(7)                                                                                               _________________________
HT: H3391 S/N 2 (3)
(8)                                                                                      (33)
HT: H3391 S/N 3 (4)
(34)
(5)
(9)                                                                                              _________________________          4 (35)
(6)
(10)                                                                                                                                    I.
(7)
I                                                    (36)
(8)
(9)
(10)
(11)
(11)
(37)
(12)
(12)                                                                                       (381 t1-                                      1.4ffi2.
I I        I I                                                                -
(14)
(14)
I          -                                      (39)                                                                                    I I                                                  (40)
(41) i                                                  (42)
(17)
(17)
(18)                                  i                                                  (43)
(1 8)
(19)                                  i                                                  (44)
(19)
(45)
(20)
(20) i                                                  (46)
(21)
(21)
I1                                                  (47)
(22)
(22)
                                                .4.                                                 (48)
(23)
(23) 4                                                    (49)
(24)
(24)                                   I      -                                            (50)
(25)
(25)                                                                                                                                                                               F At temp.
: 10. Design pressure In Numerical Order N/A N/A N/A (26)
                                                                                                      "F. Hydro.       test pressure N/A                 At temp. "F
(27)
: 10. Design pressure                  1250                psi. Temp.              575                                                          (when applicable) i Is 8 'A x Il. 12) Information in items 2 and 3 an this Data Report is
,(28)
  "*Supplemental information In the formandof lists, sketches, or drawings may be used provided (1) size the number of sheets is recorded at the top of this form.
(29)
included on each sheet is numbered 07007-2300.        Reprint (711)
(30)
(12188)                              This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300. Fairfield, NJ
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(381
+
_________________________ 4 I.
1-1.4ffi2.
I t
I i
I1
.4.
4 1250 psi. Temp.
575 (39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)  
"F. Hydro. test pressure N/A (when applicable)
At temp. F
"*Supplemental information In the form of lists, sketches, or drawings may be used provided (1) size Is 8 'A x Il. 12) Information in items 2 and 3 an this Data Report is included on each sheet is numbered and the number of sheets is recorded at the top of this form.
(12188)
This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300. Fairfield, NJ 07007-2300.
Reprint (711)
I I
I I
I I
i i
i I
nI umgll;leu 1
At temp. "F i


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
HT: H3391 S/N 1                 through       S/N 3 Certificate Holders' Serial Nos.
Certificate Holders' Serial Nos.
CERTIFICATION OF DESIGN P.E. State          N/A              Reg. no.                        N/A Design specifications certified by                           N/A (when applicable)
HT: H3391 S/N 1 through S/N 3 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A (when applicable)
N/A             Reg. no.                       N/A P.E. State certified by N/A Design report                                    (when applicable)
N/A (when applicable)
CERTIFICATE OF COMW that this (these)                                        Cover We certify that the statements made in this report are correct and 1.
P.E. State N/A P.E. State N/A CERTIFICATE OF COMW We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
conforms to the rules of construction of the ASME Code, Section III, Division N2607                            Expires                                    6-13-04            P NPT Certificate of Authorization No.
NPT Certificate of Authorization No.
Atwood & Morrill Co., Inc.                         Signed Date                                    Name                                                                            ---- _- -
Date N2607 Expires Name Atwood & Morrill Co., Inc.
(NPT Cenificat, Holder)                                                 (waud;zed mrelsmertab-)
(NPT Cenificat, Holder) 6-13-04 P
CERTIFICATE OF INSPECTION of Boiler and Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board New York                     And employed by                                                     H.S.B.I & I. Co.
Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.
items described   in this Data Report on       ,                      , and state that to the of               Hartford, CT                  have  inspected      these these parts or appurtenances       in accodance       with the ASME   Code, Section R~est of my knowledge and belief, the Certificate Holder has fabricated                              above.
of Hartford, CT have inspected these items described in this Data Report on  
authorized   for stamping       on the date   shown Divisibn 1. Each part listed has been any warranty, expressed or implied, concerning the equipment described i signing this certificate, neither the inspector nor his employer makes                                                                                                      or shall be liable in any manner for any personal Injury or property damage in this Data Report. Furthermore, neither the Inspector nor his employer tioC                                          io loss of any kind arising from or connected with this insRp Commissionst=                                   end Date                            Signedal                                                                                                              idE and state of prow.and no.]
, and state that to the R~est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accodance with the ASME Code, Section Divisibn 1. Each part listed has been authorized for stamping on the date shown above.
nmalh)
i signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this insRp tioC io Date Signedal Commissionst=
(Narl S&. (inci E (aWoflzed imaput)
end (aWoflzed imaput)
L
(Narl S&. (inci E idE nmalh) and state of prow. and no.]
Reg. no.
Reg. no.
N/A N/A Cover L
(waud;zed mrelsmertab-)


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Pg. 1 of 2 Not to Exceed One Day's Production
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by                 Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address or NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address or NPT Certificate Holder)
: 2. Manufactured for             Pennsylvania Power & Light - Berwick, PA                                     18603 (name and address of Purcnasaerj
: 2. Manufactured for Pennsylvania Power & Light - Berwick, PA 18603 (name and address of Purcnasaerj
: 3. Location of installation               Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and Bursess}
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179
                                                                      *^A'/(Q     120A                   d  S7nn PRI                           N/A                       2001
: 4. Type:
: 4. Type:              "&#xb6;jZ4I*L-oi3,-1 (drawing n., ). ev               o&#xb6;t'VA4. I=,lp%,,
Iname and Bursess}  
                                                                                -                      '..i-Is . stne-rh.
*^A'/(Q 120A dS7nn PRI N/A 2001
                                                                                                                    .    ...                  (CCRN)                   (year built)
"&#xb6;jZ4I*L-oi3,-1,
(dr-aving no.)                     lmari spec. no.)
ev o&#xb6;t'VA4. I=,lp%,,
S'71                                                              N/A
(drawing n. ).
                      .a                i                        -110-7"1                                                           1-S. ASM. Code,               on iec                                  (edibon)                   (addenda data)                       (class)                     (Code Case no.)
'..i-Is stne-rh.
N/A              Revision            N/A            Date                  N/A
(CCRN)
(year built)
(dr-aving no.)  
.a i
lmari spec. no.)  
-110-7"1 S'71 1-N/A S. ASM. Code, iec on (edibon)
(addenda data)
(class)
(Code Case no.)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 7. Remarks:           Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA the required information of ASME (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets Section III 1971 Edition Summer 1971 addenda Min. design thickness (in.)         1.36           Dia. ID (ft & in.)       N/A   . Length overall (ft& in.)           N/A
N/A Revision N/A Date N/A
: 8. Nom. Thickness (in.)              1.50 for each item of this report
: 7. Remarks:
: 9. When applicable, Certiricate Holders' Data Reports are attached Part or Appurtenance                             National Board  No.
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
Part or Appurtenance                            National                                        Serial Number Serial Number                               Board No.                                                                              In Numerical Order In Numerical Order N/A                              (26).
: 8. Nom. Thickness (in.)
      - (1)     HT:     54682 ESIN 1                                                            (27)
1.50 Min. design thickness (in.)
(2)      HT:     54682," S/N 2                          N/A N/A                              -(28)
1.36 Dia. ID (ft & in.)
(3)     HT:     54682 S/N 3                                                              (29)
N/A  
(4)    HT:     54682 E IN 4                          N/A (30)
. Length overall (ft& in.)
(5)    HT: 54682 3/N            5                    N/A (31)
N/A
(6)    HT: 54682 , S/N          6                    N/A (32)
: 9. When applicable, Certiricate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number
(7). HT:54682, 3/N            8                   N/A (33)
- (1)
(8)    HT: 54682 S/N            9                    N/A (34)
HT: 54682 E (2)
(9)
HT: 54682,"
(35)
(3)
HT: 54682 (4)
HT: 54682 E (5)
HT: 54682 (6)
HT: 54682,
(7).
HT:54682, (8)
HT: 54682 (9)
(10)
(10)
(36)
(11)
(11)
(37)
(12)
(12)                                    i (39)
(14)
(14)                                                                                      (40)
(15)
(15)
(41)
(16)
(16)
(42)
(17)
(17)
(43)
(18)
(18)
(44)
(19)
(19)
(45)
(20)
(20)
(46)
(21)
(21)
(47)
(22)
(22)
(48)
(23)
(23)                                    I                                                  (49)
(24)
(24)
(50)
(25)
(25)
I "F.     Hydro. test pressure                 N/A               At temp. "F
: 10. Design pressure SIN 1 National Board No.
: 10. Design pressure                    1250            psi. Temp.                575 (when applicble)
In Numerical Order N/A S/N 2 N/A S/N 3 N/A IN 4 N/A 3/N 5 N/A S/N 6 N/A 3/N 8 N/A S/N 9 N/A 1250 psi. Temp.
Data Report is be used provided (1) size is 8 'A x 11, (2) Information in items 2 and 3 on this
575 Part or Appurtenance Serial Number (26).
  -Supplemental information in the form of lists, sketches, or drawings may of this form.
(27)
included on each sheet Is numbered and the number of sheets is recorded at the top
-(28)
* Reprint (71 Sl)
(29)
NJ 07007-2300.
(30)
(12J88)                                 This form (EO0040) may be obtained from th. Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield,
(31)
(32)
(33)
(34)
(35)
(36)
(37)
National Board No.
In Numerical Order (39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
"F.
Hydro. test pressure N/A At temp. "F
-Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 'A x 11, (2) Information in items 2 and 3 on this Data Report is included on each sheet Is numbered and the number of sheets is recorded at the top of this form.
(12J88)
This form (EO0040) may be obtained from th. Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007-2300.
Reprint (71 Sl)
(when applicble) i I
I


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.       HT: 54682 S/N 1               through         S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by                         N/A                         P.E. State       N/A            Reg. no.                          N/A (when applicable)
Certificate Holders' Serial Nos.
P.E. State       N/A           Reg. no.                         N/A Design report* certified by                          N/A (when applicable)
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)                                       Pilot Poppet conforms to the rules of construction of the ASME Code, Section I1l, Division 1.
N/A (when applicable)
NPT Certificate of Authorization No.                         N2607                         Expires                                 6-13-04         -a Name            Atwood & Morrill Co., Inc.                   Signed Date             Ll&#xfd;0 (NPT Cerbtlcate HoNder)                                          (authorized rerewbabmt)
P.E. State N/A P.E. State N/A Reg. no.
N/A Reg. no.
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section I1l, Division 1.
NPT Certificate of Authorization No.
N2607 Expires Pilot Poppet 6-13-04  
-a Atwood & Morrill Co., Inc.
(NPT Cerbtlcate HoNder)
Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.l & 1. Co..
of Hartford, CT have inspected these items described in this Data Report on
, and state that to the
,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordd ncefwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date Sge Commissions
"!pd.nn--
=d iseM
-(Nafl Bd. (fnd. Endomemants) and out@ or pm.,. and n.
Date Ll&#xfd;0 Name New York (authorized rerewbabmt)
H.S.B.I I.
Co.
Co.
I.
CERTIFICATE OF INSPECTION                            &
State or Province of I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the H.S.B.I New York                    And employed by                                                H.S.B.l & 1.Co..
have inspected these items described in this Data Report on                                        , and state that to the of                Hartford, CT In  accordd    ncefwith  the  ASME      Code, Section
  ,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances Division 1. Each part listed has been  authorized  for stamping    on  the  date  shown  above.
equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the or property damage or in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury loss of any kind arising from or connected with this inspection.
Date                            Sge                                                                Commissions
                                                              "!pd.nn--
                                                                      =d iseM                                        -(Nafl Bd. (fnd.Endomemants) and out@ or pm.,. and n.


&#xfd;&#xfd;wqlfwu Lu. r , I -                                                            u-U.r INt-UtIIIVI. I lUlV UnIL Y                                                             Expires On: V??
u-U.r INt-UtIIIVI.
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
I lUlV UnIL Y FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                           Pq. 1 of 22 P9. 1 of
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
: 1. Manufactured and certified by             Atwood & Morri? Co., Inc. 285 Canal Street Salem, MA 01970 (name and adoress o NPT Certfkcate Holder)
: 1. Manufactured and certified by Atwood & Morri? Co., Inc. 285 Canal Street Salem, MA 01970 (name and adoress o NPT Certfkcate Holder)
: 2. Manufactured for         Pennsylvania Power & Light                     Berwick, PA 18603 (name an addMres of PurChaser)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name an addMres of PurChaser)
: 3. Location of installation         Susquehanna II 2 North Ninth Street Allentown. PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown. PA 18101-1179 (name and address)
: 4. Type:           *32467-622-D Rev.7                       *SA 105 GR II                      77+100 PSI                          N/A                          *3nl I                           t%0m"nq no.I                       (malnrapc nS.p.
: 4. Type:  
                                                                                              - SA105  T7 00  R 1 SI                      NA t*CfI 2041
*32467-622-D Rev.7 I
: 5. ASME Code, Section III,Division 1:                         1971                                                       1 S71                                                         N/A (addena. "toj                 . -400")                      !oidecam,a&)  58.1
t%0m"nq no.I
: 5. ASME Code, Section III, Division 1:
* SA 105 GR II (malnr apc nS.p.
1971 77+100 PSI S71 (addena. "toj
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
N/A             Revision           N/A           Data                   N/A (no.)
N/A (no.)
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section I11   1971 Edition summer 1971 addenda
Revision N/A Data N/A
: 8. Nom. Thickness (in.)         7.312         Min. design thickness (in.)       5.49         . Ola. ID (ft & in.)     N/A   'Length overall (Rt&in.)             N/A
: 7. Remarks:
: 9. When applicable, Certificate Holders' Data Reports we attached for each item of this report Pad or Appurtenance                           National                                Part or Appurtenance                        National Serial Number                            Board No.                                    Serial Number.                          Board No.
Cust. Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section I11 1971 Edition summer 1971 addenda
In Numerical Order                                                                    In Numerical Order (1)  HT: 245951 S/N 3                              N/A                          (25)
: 8. Nom. Thickness (in.)
7.312 Min. design thickness (in.)
5.49  
. Ola. ID (ft & in.)
N/A  
'Length overall (Rt& in.)
N/A
: 9. When applicable, Certificate Holders' Data Reports we attached for each item of this report Pad or Appurtenance Serial Number (1)
(2)
(2)
C (27)
(3)
(3)                                                                                (28)
(4)
(4)                                                                                (29)
(5)
(5)                                                                                (30)
(6)
(6)                                                                                (31)
(7)
(7)                                                                                (32)
(a)
(a)                                                                                (33)
(Q)
(Q)
(10)
(10)
(11)                                                                                (36)
(11)
(12)
(12)
(38)
(13)
(13)
J(14)                                                                                (36)
J(14)
(IS)                                                                                (40)
(IS)
(16)                                                                                (41)
(16)
(17)                                                                                (42)
(17)
(18)
(18)
(19)
(20)
(21)
(22)
(P)
(24)
(25)
HT: 245951 S/N 3
: 10. Design pressure National Board No.
In Numerical Order N/A 1250 paL Temp.
Part or Appurtenance National Serial Number.
Board No.
In Numerical Order (25)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(36)
(38)
(36)
(40)
(41)
(42)
(43)
(43)
(19)
(44)
(44)
(20)                                                                                (45)     _
(45)
(21)                                                                                (48),_________
(48),_________
(22)                                                                                (47)
(47)
(P)                                                                                (48)
(48)
(24)                                                                                (49)       _      _      _      _              _      _      _        _
(49)
(25)                                                                                (50)
(50) 575
: 10. Design pressure                1250            paL    Temp.            575          'F.     Hydra. test pressure               N/A               At temp. &deg;F towhen        me)
'F.
        "SupplementlW information in the form of Isle. sketches, of drawkngs m*a be used provided (II sie Is I Ya 11. (2 information In hItms 2 and 3 on dtis Data ReporitIs Included as each shoot is numbsen and MIenumber of shouta Is racorded at t. top of MWIfasr;.
Hydra. test pressure N/A towhen me)
11211111                            Thisform iE0O40) may be obtalned from the Orcer Dept.. ASME. 22 Law Drlve. 8= Z=. FaMold. KJ 07007-2=
At temp. &deg;F "SupplementlW information in the form of Isle. sketches, of drawkngs m*a be used provided (II sie Is I Ya 11. (2 information In hItms 2 and 3 on dtis Data ReporitIs Included as each shoot is numbsen and MIe number of shouta Is racorded at t. top of MWI fasr;.
Thisform iE0O40) may be obtalned from the Orcer Dept.. ASME. 22 Law Drlve. 8= Z=. FaMold. KJ 07007-2=
P9. 1 of 2 N/A 1
- SA105 R 1 T7 00 SI NA 2041 N/A
!oidecam
,a&) 58.1 C
Pq. 1 of 2
&#xfd;&#xfd;wqlfwu Lu. r, I -
Expires On: V??
*3nl t*CfI
. -400")
11211111


-&#xfd;wwl ICU &U. : -.,                                                          rtjn* llvrurl&#xa5;1v* I IUIv UIrLT                                                           tLxpires On: 1??
rtjn* llvrurl&#xa5;1v* I IUIv UIrLT Repuint 17191)
Repuint 17191)
FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos. HT: 245951 S/N 3             through     N/A CERTIFICATION OF DESIGN Design specifications certified by         'N/A                                         P.E.      N(A              Reg. no.              N/A State (when~ apocabie)
Certificate Holders' Serial Nos.
Design report
HT: 245951 S/N 3 through N/A CERTIFICATION OF DESIGN Design specifications certified by Design report
* certified by              N/A                                           P.E.     N/A               Reg. no.              N/A State (Whel applicable)
* certified by
CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these)
'N/A (when~ apocabie)
                                                                                                                                .Poppet conforms to the rules of construction of the ASME Code, Section 1II,Division 1.
N/A (Whel applicable)
NPT Certificate of Authorization No.                         N2607                       Expires                           6-13-04 Date                                  Name            Atwood & Morrill Co.. Inc.
P.E.
(NPT Cev~fuit HOWe)
State P.E.
Signed           .:                            ii*
State N(A N/A CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section 1II, Division 1.
CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and th State or Province of New York                      And employed by                                             H.S.B.I & I. Co.
Reg. no.
of             Hartford, CT                 have inspected these items described in this Data Report on         47/     ,/0/         and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code. Section 111,ODvision 1. Each part listed has been authorized for stamping on the date shown above.
Reg. no.
N/A N/A
.Poppet NPT Certificate of Authorization No.
Date N2607 Name Expires Atwood & Morrill Co.. Inc.
(NPT Cev~fuit HOWe) 6-13-04 Signed CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and th State or Province of And employed by H.S.B.I & I. Co.
of Hartford, CT have inspected these items described in this Data Report on 47/  
,/0/
and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code. Section
: 111, ODvision 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shill be liable In any manner for any personal Injury or property damage or loss of any kdnd arising from or connected with this Inspection.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shill be liable In any manner for any personal Injury or property damage or loss of any kdnd arising from or connected with this Inspection.
Date                            Signed                                                            Commissions     4j)>'&#xfd;               g   Ai.1
Commissions 4j)>'&#xfd; g
(~n at d. Pnd. Endrsfmvnf) and $af   at pm. sad ro.)
Ai.1
(~n at d. P nd. Endrsfmvnf) and $af at pm. sad ro.)
I.
I.
New York Date Signed ii*
-&#xfd;wwl ICU &U. : -.,
tLxpires On: 1??


FORM NR-1             REPORT OF REPAIR I                   MODIFICATION ED                   OR REPLACEMENT [X]
FORM NR-1 REPORT OF REPAIR I MODIFICATION ED OR REPLACEMENT [X]
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 1. Work performed by           Continental           Field       Sqystems,           Tnc                               3218 (name of NR certificate holder)                                           (P.O. no., job no., etc.)
: 1. Work performed by Continental Field Sqystems, Tnc 3218 (name of NR certificate holder)
23 Westgate Blvd.                     Savannah,           GA 31405 (address)
(P.O. no., job no., etc.)
: 2. Owner           PPT. T.I.C (name) 2 North Ninth Street.                       Allentown,               PA 18101 (address)
23 Westgate Blvd.
: 3. Name, address and identification of nuclear power plant                   Susquehanna Steam Electric 5 Miles North of Berwick, PA                                                 Salem,         Twp,     PA 4.System         1-83     HV141FO28B                         Main Steam
: Savannah, GA 31405 (address)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                       See Attached Identification                                                       Construction Code                           Activity Type of         Mfg.         Mfg. Nat'l Bd. Jurisd.       Other       Year       Name/         Edition/       Code           Code         Repair/
: 2. Owner PPT.
No   Item         Name       Serial No. No.       No.                   Built       Section/       Addenda       Case(s)         Class         Mod/
T.I.C (name) 2 North Ninth Street.
Division                                                   Replace 2
Allentown, PA 18101 (address)
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA
: Salem, Twp, PA 4.System 1-83 HV141FO28B Main Steam
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 8
7 8
: 5. b: Items Installed During Replacement Activities               q*       Ar t nrhPd Identification                                                             Construction Code Type of       Installed or. Mfg.       Mfg       Nat'l Bd.       Jurisd     Other       Year     Name/       Edition/ rCode                 Code Item           Replaced       Name     Serial No.       No.           No                   Built   Section/     Addenda Case(s)               Class 5a Item No.                                                                               Division
: 5. b: Items Installed During Replacement Activities q*
: 6. ASME Code Section )G applicable for inservice inspection:                 1989                           N/A                         N/A (edition)                 (addenda)                   (Code Cases(s))
A r t nrh Pd Identification Construction Code Type of Installed or.
: 7. ASME Code Section )a used for repairs, modifications, or replacements:                         19 89             N1iA                  N/A S(edition)                                                                                               (addenda)               (Code Cases(s))
Mfg.
: 8. Construction Code used for repairs, modifications, or replacements:                         1971                   S 71                     N/A (edition)         (addenda)               (Code Ca~ses(s))
Mfg Nat'l Bd.
: 9. Design responsibilities:       Atwood & MorrIl                   Co.
Jurisd Other Year Name/
: 10. Tests conducted: hydrostatic D]         pneumatic []       design pressure D]             pressureNA.__       psi Code Case(s)
Edition/ rCode Code Item Replaced Name Serial No.
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                           Rev. 8
No.
No Built Section/
Addenda Case(s) Class 5a Item No.
Division
: 6. ASME Code Section )G applicable for inservice inspection: 1989 N/A N/A (edition)
(addenda)
(Code Cases(s))
: 7. ASME Code Section )a used for repairs, modifications, or replacements:
19 89 N1 iA N/A S(edition)
(addenda)
(Code Cases(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 S 71 N/A (edition)
(addenda)
(Code Ca~ses(s))
: 9. Design responsibilities:
Atwood & MorrIl Co.
: 10. Tests conducted: hydrostatic D] pneumatic []
design pressure D]
pressureNA.__ psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
: 11. Descriotion of work:
5 i c At- -
I-, A (use of properly identified additional sheet(s) or sketch(es) is acceptable)
: 12. Remarks:_
See attached manufacturer's data report i--
CERTIFICATE OF COMPLIANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-86 to use the "NR" stamp expires 5/25 2003 NRCertificate Holder Continental Field Systejs, Inc Date 6/18 2002 Signed Quality Control Manager CERTIFICATE OF INSPECTION I,
$ilA,&.
17
'-i 0
, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of PENN S Yo.
V4 N14 and employed by C~crory MuruAL tMsur4mce" Cea"*,w jy
-of JoN70W oS
"*?q have inspected the repair, modification or replacement described in this report on Z00, 2OO-and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XG of the ASME Code and the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of kind arising from or connected with this inspection Date obuNer Z +
4 2P-,
SigneM *
.*-4/*,P r
Commissions A/8798DA.*.Z 5PA4ZO (inspect (National Board (inc. endorsements), t-risdition, and no.)
(title) l-.......
(a-uthorized representative)


i--
I Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.
: 11. Descriotion l- .......
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B Report of Repair / Replacement Job Number 3218 Items Installed During Replacement Activities Identification Installed/
of work:
MFG.
5 ic    At- -      I-, A (use of properly identified additional sheet(s) or sketch(es) is acceptable)
Mfg. Serial Replaced Name No.
: 12. Remarks:_                    See attached manufacturer's                              data report CERTIFICATE OF COMPLIANCE I,    David McCathie                        certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
Replaced WSI I
National Board Certificate of Authorization No.                       NR-86                  to use the "NR" stamp expires              5/25          2003 NRCertificate Holder Continental                          Field Systejs,                    Inc Date      6/18              2002 Signed ___                    _________                                        Quality Control Manager
Replaced A&M 4
                                                %.-          (a-uthorized representative)                                            (title)
Replaced A&M 4
CERTIFICATE OF INSPECTION I,      '-i .
Replaced A&M NU-01017 Nat'l Bd. No.
      $ilA,&            17    0          , holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of PENN S Yo.                               V4 N14                      and employed by C~crory MuruAL tMsur4mce" Cea"*,w                                    jy                      -of     JoN70W          oS      "*?q                          have inspected the repair, modification or replacement described in this report on                                              Z00,2OO- and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XGof the ASME Code and the National Board Inspection Code "NR" rules.
N/A N/A N/A N/A Jurisd. No.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of                        kind arising from or connected with this inspection Date obuNer Z +          4    2P-,
N/A N/A N/A N/A Other Year Built Name/
* SigneM *                          *-4/*,P
Section/
                                                                        .              r            Commissions A/8798DA.*.Z                        5PA4ZO (inspect                            (National Board (inc. endorsements), t-risdition, and no.)
Division N/A 2001 III NB N/A 1
2001 111 NB N/A 201IIN N/A N/A 2001 2002 III NB Ill NB Construction Code Edition/
Code Code Addenda Case(s)
Class 71 Ed. S71 A N/A I
71E.S71 A 71 Ed. S71 A N/A N/A I
L _____
.1 _______
L ____
I ______
I ______
: 1.
I.
I ______
1 of 2 "I
Item Poppet Bonnet Pilot Poppet Super Nuts 71 Ed. S71 A N/A I


I                    Form NR-1 Attachment                                       Report of Repair / Replacement                                           "I Worked Performed by Continental Field Systems, Inc.
Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.
Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B Items Installed During Replacement Activities Identification Item                                                                                                                        Construction Code Installed/    MFG.      Mfg. Serial      Nat'l      Jurisd. No. Other    Year Built      Name/            Edition/      Code          Code Replaced      Name          No.          Bd. No.                                              Section/        Addenda        Case(s)        Class Division Poppet        Replaced      WSI            I            N/A            N/A        N/A          2001        III NB      71 Ed. S71 A        N/A            I Bonnet      Replaced      A&M            4            N/A            N/A        N/A  1      2001        111 NB      71 Ed. S71 A        N/A            I Pilot Poppet    Replaced      A&M            4                            N/A                      N/A              201IIN N/A                        N/A          2001                          71E.S71 A    N/A Super Nuts    Replaced      A&M        NU-01017          N/A            N/A        N/A          2002        III NB      71 Ed. S71 A Ill NB                          N/A            I L _____    .1_______        L____    I ______      I ______      1.________        I.
Job Number 3218
____      I______
(
1 of 2
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 'h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B
 
: 6. ASME Code Section X1 applicable for inservice inspection: 1989 N/A N/A (edition)
Form NR-1 Attachment                                          Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.                                      Job Number 3218
(addenda)
( 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 'h St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B
(Code Case(s))
: 6. ASME Code Section X1 applicable for inservice inspection: 1989                   N/A             N/A (edition)           (addenda)       (Code Case(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:]1989 N/A N/A (edition)
: 7. ASME Code Section XI used for repairs, modifications, or replacements:]1989             N/A           N/A (edition)         (addenda)       (Code Case(s))
(addenda)
: 8. Construction Code used for repairs, modifications, or replacements:   1971             Summer 71       1 (edition)         (addenda)       Code Case
(Code Case(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 Summer 71 1
(edition)
(addenda)
Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
Line 1,862: Line 3,614:


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of         2 Weldina Services. Inc. 2225 Skyland Court, Norcross GA, 30071
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of 2
: 1.     Manufactured and certified by                                                                                       Court, Norcross       GA, 30071 Welding Services, (nameInc. addressSkyland and 2225      of NPT Certificale Holder)
: 1.
Atwood & Morril Co. 285 Canal Street. Salem, MA 01970
Manufactured and certified by
: 2.      Manufactured for                                                                  (name and address of Purchaser)
: 2.
PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603
Manufactured for
: 3.      Location of installation (name anadri(oess) 70.0 Ksi"                                N/A                                2001
: 3.
: 4.     Type:         A& M DO -                    SA 105 Gr.
Location of installation Weldina Services. Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificale Holder)
32467-622 R/7 (mat'l. spec. no.)               (tensile strength)                           (CRN)                           (year built)
Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
(drawing no.)
PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name anadri (oess)
: 5.     ASME Code, Section III, Division 1:                     1971                       S 1971                                 1                               N/A (edition)                 (addenda date)                         (class)                     (Code Case no.)
: 4.
N/A              Revision                  N/A              Date            N/A
Type:
: 6.     Fabricated in accordance with Const. Spec. (Div. 2 only)
A& M DO SA 105 Gr.
(no.)
70.0 Ksi" N/A 2001 32467-622 R/7 (drawing no.)
: 7.       Remarks:           21" MSIV Valve Poppet SA 105 Gr.lI with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 forSA 105 Gr. II for Stellite 21 "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 Min. design thickness (in.)     NIA               Dia. ID (f   &      0in.)
(mat'l. spec. no.)
21"0 ,.        Length overall (ft& in.)    31'
(tensile strength)
: 8.       Nom. Thickness (in.)        NIA                                                                                    SO
(CRN)
: 9.      When applicable, Certificate Holder's Data Reports are attached for each Item of this report:
(year built)
National                                      Part or Appurtenance                            National Part or Appurtenance                         National                                          Serial Number                             Board  No.
: 5.
Serial Number                          Board No.                                                                              In Numerical Order In Numerical Order 1(1)      9'951--1-1                                                                       (26)                                            4 24595                                                                         (27)
ASME Code, Section III, Division 1:
(2)  94dSq1I-2 24595-2.
1971 S 1971 1
I (28) _________________________________ 4.
N/A (edition)
              '*ac.(:* 1 ..4 (3)   24595114                                                                        (29)
(addenda date)
              ')AO1 (4)   245951-5 (30)
(class)
(5)  24*5951-7                                                                        (31) 245951-7
(Code Case no.)
              ')AO4      .A (6)        45951                                                                    (32)
: 6.
(7)  *4595ts -9 245951-                                                              (33)
Fabricated in accordance with Const. Spec. (Div. 2 only)
(8)                                    1                                              (34)
N/A Revision N/A Date N/A (no.)
(9)                                    .4.
: 7.
Remarks:
21" MSIV Valve Poppet SA 105 Gr.lI with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21
: 8.
Nom. Thickness (in.)
NIA Min. design thickness (in.)
NIA Dia. ID (f
: 9.
When applicable, Certificate Holder's Data Reports are attached for each Item of this report:
Part or Appurtenance Serial Number 9'951-- 1-1 24595 94dSq1I-2 24595-2.
')AO1
-
24*5951-7
')AO4  
.A
*4595ts -9 45951 245951-
1
.4.
+
+
4
'I
: 10.
Design pressure N/A National National Board No.
In Numerical Order psi.
: Temp, (26)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(35)
(10)                                                                                     (36)
(36)
                                                +
(37)
(11)                                     +                                              (37)
(38) 0in.)
(12)                                     4                                              (38)
21"0,.
I (13)                                                                                                                       -
SO Part or Appurtenance Serial Number 4
(14)                                                                                     (40)
I
(15)                                                                                     (41)
_________________________________ 4.
(16)                                                                                     (42)
National Board No.
(17)                                                                                     (43)
In Numerical Order (40)
(18)                                                                                     (44)
(41)
(19)                                                                                     (45)
(42)
(20)                                                                                     (46)
(43)
(21)                                                                                     (47)
(44)
(22)                                                                                     (48)
(45)
(46)
(47)
(48)
(49)
(50)
N/A
*F Hydro. test pressure NIA at temp. 'F (when applicable)
*Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 81 x 11, (2) information in items 2 and 3 on this Data Report is included or each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/88)
This form (E00040) may be obtained from the Order Dept.. ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
Reprint (7191) 1VJbrarysvr~quahity_a %Project FiestAtwood & MornA2001031140 )Oct 2001)W2-31140.doc 1(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(23)
(49)
(24)
(24)                                                                                    (50)
(25)
(25)                                 'I N/A          *F      Hydro. test pressure              NIA              at temp. 'F N/A                    psi. Temp,                                                              (when applicable)
Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 24595114 245951-5 245951-7 I
: 10. Design pressure 2 and 3 on this may be used provided (1) size is 81 x 11, (2) information in items
Length overall (ft& in.)
  *Supplemental information in the form of lists, sketches, or drawings                                          recorded  at the  top of this form.
31'
and the  number    of sheets  is Data Report is included or each sheet, (3) each sheet is numbered 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
'*ac.(:* 1..4
(12/88)                                       This form (E00040) may be obtained from the Order Dept.. ASME                                                          Reprint (7191) 1VJbrarysvr~quahity_a%Project      FiestAtwood & MornA2001031140 )Oct 2001)W2-31140.doc


FORM N-2 (Back               - Page 2 of 2             )
FORM N-2 (Back - Page 2 of 2 )
Certificate Holders Serial Nos.       Ht # 245951               through     1,2.4.5,7,8,9 CERTIFICATION OF DESIGN P.E. State                   CA             Reg. NoA         13655 Boyd P. Brooks Design Specifications certified by (when applicable)
Certificate Holders Serial Nos.
P.E. State                   MA             Reg. No..         10981 Herbert Cook Design Report" certified by                            (when applicable)
Ht # 245951 through 1,2.4.5,7,8,9 CERTIFICATION OF DE Design Specifications certified by Design Report" certified by Boyd P. Brooks (when applicable)
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)               21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
Herbert Cook (when applicable)
N-2873                                                               x ires       Nove       13,2004 NPT Certificate of Authorization No.
SIGN P.E. State CA Reg. NoA 13655 P.E. State MA Reg. No..
Date     12-10-01               Name     -Welding Services Inc.                                 Sig                                                     eP G:7u.
10981 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
                                                                                                                        -          authorized represenlalive)
NPT Certificate of Authorization No.
(NPT Certificate Holder)
N-2873 x ires Nove 13,2004 Date 12-10-01 Name  
                                                                                                          //U CERTIFICATE OF INSPECTION.
-Welding Services Inc.
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and                 the State or Province of and employed   by       The Hartford   Steam   Boiler Inspection and Insurance Co.
Sig G:7u.
Georgia have inspected these items described in this Data Report on                 December 10, 2001                 and state that to the of      Hartford,. CT best of my knowledge and belief, the Certificate Holder has fabricated               these   parts or appurtenances     in accordance     with ASME     Code, Section III.
eP (NPT Certificate Holder) authorized represenlalive)  
//U CERTIFICATE OF INSPECTION.
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section III.
Division 1. Each part listed has been authorized for stamping on the date shown above.
Division 1. Each part listed has been authorized for stamping on the date shown above.
equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerningor the                 property  damage or loss his employeE     shall be liable in any manner     for any   personal   injury in this Data Report. Furthermore, neither the inspectorIor of any kind arising from or connected wi this ins         ion.               _____
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspectorIor his employeE shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this ins ion.
Date     12-10-01           Signed                                                       Commissions         NB # 11465 ABN, GA # 393 (Auth i                   or)                               [ Nall. Bd. (inc. Endorsements) and state or pray. and no.)
Date 12-10-01 Signed Commissions NB # 11465 ABN, GA # 393 (Auth i or)
F Wibrary_svrquaity_a VProjecf FieslAtwood & Morrillt2001l31140)Oct 2001)W2-31140.doc
[ Nall. Bd. (inc. Endorsements) and state or pray. and no.)
Wibrary_svrquaity_a VProjecf FieslAtwood & Morrillt2001l31140 )Oct 2001)W2-31140.doc F


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                 Pg.1 of 2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
: 1. Manufactured and certified by                   Atwood & Morrill Co., Inc. 285 Canal Street                           Salem, MA 01970 (name and address of NPT Certificate Molder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970
: 2. Manufactured for             Pennsylvania.Power & Light                     Berwick, tnc. -
: 2. Manufactured for Pennsylvania.Power & Light Berwick, PA 18603 tnc.
PA- ,,* 18603
l l Iname anu au wress v**=*
                                                                                                        - , - l l --
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and addressl A
Iname anu au     wress     v**=*
Ttnm  
: 3. Location of installation             Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and addressl A     Ttnm                                     Rv    I         SA a.105   GR Rev.

II             77.900 PSI                                  N/A                      2001
Rv I
  . Typ
SA 105 GR II
* 1ec.6                               _1n
: a.
                                                                                                              *1,mt-~r
* 1ec.6 Rev.
(
_1n  
                                                                                                                                                                          *mi (drawing no.)                    (m7ar1 ec. no.)
*1,mt-~r  
(71                                                            N/A
*mi (m7ar1 ec. no.)
(drawing no.)
: 5. ASME Code, Section III, Division 1:
: 5. ASME Code, Section III, Division 1:
1 1971na                S71      a                      1iai'-
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(addenda date)                      (class)
(71 1971na S71 a
Date                  N/A
1iai'-
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                         'N/A               Revision             N/A
'N/A 1
: 7. Remarks:             Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
Revision N/A N/A Date N/A
: 8. Noa. Thickness           (in.)   5.312         Min. design thickness (in.)       5.094         Dia. ID (ft & In.)       N/A          Length overall (ft& In.)          N/A
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
: 8. Noa. Thickness (in.)
5.312 Min. design thickness (in.)
5.094 Dia. ID (ft & In.)
N/A
: 9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:
: 9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:
National                                Part or Appurtenance                                  National P=art or Appurtenance                                                                     Serial Number                                   Board No.
=art or Appurtenance Serial Number I-T" H*Q1 S*/N 4 National Board No; In Numerical Order N/A HT: H3391 S/N 5 N/A HT: H3391 S/N 6 N/A I;
Serial Number                            Board No; In Numerical Order In Numerical Order I-T" H*Q1 S*/N 4                             N/A                           (26)
*I.
J    (1)                                                                                          __________________________        4-(27)
.1.
(2)      HT: H3391 S/N 65                            N/A                                   __________________________        +
Part or Appurtenance Serial Number (26)
(27)
(28)
(28)
        .(3)                                                                                          __________________________        +
(29)
(29)
(4)                                                                                                                            1 (30)   __________________________
(30)
(5)                                                                                          _________________________        +
(31)
(31)
(6)                                                                                         _________________________         4 (32)
(32)
(33)
(34)
-(35)
(36)
(37)
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
__________________________ 4-
__________________________ +
__________________________ +
__________________________ 1
_________________________ +
_________________________ 4 t
4 I
Length overall (ft& In.)
N/A National Board No.
In Numerical Order
: 10. Design pressure 1250 psi.
Temp.
575 "F. Hydro. test pressure "Supplemental Information In the form of lists, sketches, or drawings may be used provided (1) size is 8 V. x 11.12) Information In items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
This form 1E00040) may be obtained from the Order Dept., ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300.
Pg.1 of 2 77.900 PSI N/A 2001 J
P (1)
(2)
.(3)
(4)
(5)
(6)
(7)
(7)
(8)                                                                                  (33)
(8)
(34)
(9)
(9)
                                                                                                -(35) _____________________________________________________
(10)
t (10)
(1)
(1)                                                                                  (36)
(12)
(12)                                                                                  (37)
(14)
(14)                                                                                  (39)
(40)
(15)
(15)
(41)
(16)
(16)
(42)
(17)
(17)
(18)                                                                                  (43)
(18)
I; (19)                                                                                  (44)
(19)
(20)                                                                                  (45)
(20)
(21)                                                                                  (46)
(21)
(22)                                                                                  (47)
(22)
(48)
(23)
(23)
                                                *I.                                            (49)
(24)
(24)                                                                                                                              4
(25)
                                                .1.                                            (50)
N/A (when appliicable)
(25)                                                                                                                             I L-At temp. "F
At temp. "F (name and address of NPT Certificate Molder)
: 10. Design pressure                  1250            psi. Temp.            575          "F. Hydro.        test pressure                  N/A (when appliicable)
L-
In items 2 and 3 on this Data Report Is "Supplemental Information In the form of lists, sketches, or drawings may be used provided (1) size is 8 V. x 11.12) Information Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
. Typ
NJ 07007-2300.
(
(1211118)                             This form 1E00040) may be obtained from the Order Dept., ASME. 22 Law Drive. Box 2300, Fairfield.                            Reprint ('7191)
(class)
(addenda date)
(1211118)
Reprint ('71 91)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.         HT: H3391         S/N 4           through         S/N 6 CERTIFICATION OF DESIGN P.E. State          N/A          Reg. no.                          N/A Design specifications certified by                         N/A (when applicable)
Certificate Holders' Serial Nos.
P.E. State         N/A           Reg. no.                           N/A Design report' certified by                            N/A (when applicable)
HT: H3391 S/N 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by N/A (when applicable)
CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these)
Design report' certified by N/A (when applicable)
Cover conforms to the rules of construction of the ASME Code, Section III, Division 1.
P.E. State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
N2607                        Expires                                  6-13-04            ,,.
NPT Certificate of Authorization No.
NPT Certificate of Authorization No.
Signed Date                                  Name             Atwood & Morrill Co., Inc.                                                 (au-vooze.l representative)
Name N2607 Expires Atwood & Morrill Co., Inc.
                                                                          ,akld)
(NPT Crtfcate
(NPT Crtfcate CERTIFICATE OF INSPECTION Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure kM    Vrnrle                And employed by                                                   H.S.B.I & I. Co.
,akld)
of my   Hartford, CT               have inspcted these items described in this Data Report on                   _,                      and state that to the ASME Code, Section
Signed (au-vooze.l representative)
  .,st of my knowledge and belief, the Certificate'Holder has fabricated these parts or appurtenances in accordance-with the
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.
of my Hartford, CT have inspcted these items described in this Data Report on and state that to the  
.,st of my knowledge and belief, the Certificate'Holder has fabricated these parts or appurtenances in accordance-with the ASME Code, Section
,n, Division 1. Each part listed has been authorized for stamping on the date shown above.
,n, Division 1. Each part listed has been authorized for stamping on the date shown above.
expressed or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, Report. Furthermore,   neither the inspector   nor his employer   shall be liable In any manner for any personal Injury or property damage or in this Data loss of any kind arising from or connected     with this Inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection.
Signed                                                                                                                           .Commissions Date       47
Date 47 Signed  
                                                    =         (audkorizd         I*s*tr                             [NaVl Bd. (incl. EndiosrseentS} =NWstar- or prov. and ne.I
.Commissions Reg. no.
Reg. no.
N/A N/A Date Cover kM Vrnrle 6-13-04
.. =
(audkorizd I*s*tr
[NaVl Bd. (incl. EndiosrseentS} =NW star-or prov. and ne.I


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                       Pg. I of 2 Manufactured and certified by                     Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cartficate Holder)
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cartficate Holder)
: 2. Manufactured for                 Pennsylvania Power & Light - Berwick, PA .18603 (name and address or Purchaser)
: 2. Manufactured for Pennsylvania Power & Light - Berwick, PA.18603 (name and address or Purchaser)
: 3. Location of installation                   Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name. and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name. and address)
A   -r,.,.           'A1'&J               ~-              fl0,           RA 47Q-:*f'4.                       85.700 PSI                                     N/A                         2001
A  
-.    ,yi.
-r,.,.  
  . Tjp        e:    *3246261.--3l j                      C/I R . v.
'A1'&J  
                                                                      .  .      S..

                                                                            ,---,  ..    . *i,*             85i  ,700
fl
                                                                                                                        ;J. . PSI-t   h),t,                     (C,RN)                     iywar built)
,yi.
(drawing no.)                          1Mrl7. Spec. no.)                  (ten iltng 1                                N/A
(drawing no.)
: 5. ASME Code, Section III, Division 1:                                            1971nd                         dS71(les (edition)                  (addenda date)                        (class)
: 5. ASME Code, Section III, Division 1:
Date                  N/A
RA 47Q-:*f'4.
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                                      N/A               Revision                N/A (no.)
1Mrl7. Spec. no.)
: 7. Remarks:             Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
(edition)
: 8. Nom. Thickness (In.)                   1.50         Min. design thickness (in.)               1.36           Dia. ID (ft & in.)           N/A         Length overall (ft& in.)           N/A
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only) 85.700 PSI N/A 2001 e:
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report National                                  Part or Appurtenance                                   National Part or Appurtenance                                                                                      Serial Number                                 Board No.
j
Serial Number                                      Board No.                                                                                    In Numerical Order In Numerical Order (28)
*3246261.--3l  
(1)    HT: 54682 S/N 1                                        N/A                                                                           1-(2)                                                                                              (27)          ______________________________________
~- C/I R
HT:     54682         SIN     2                       N/A                                                                           I (28)
: v. 0, 85i
(3)    HT:     54682         SIN     3                       N/A (29)
,700 PSI-S..  
      -0)        HT:     54682         S/N     4                       N/A                                                                           *1 HT:     54682         S/N     91/                                                     (30)          _________________________________________________
. *i,*  
(5)    HT:     54682         S/N   5                        N/A (31)
;J.
(6)    HT:     54682         S/N    6                      N/A                                                                           *1 (32)          _________________________________________________
t h),t, (C, RN) iywar built)
(7). HT:     54682         S/ON  8                        N/A                                              _______________________      '1*
(t iltng en 1971nd dS71(les N/A (no.)
(8)                                                                                             (33)
1 Revision N/A Date N/A N/A
(9)                                                                                             (34)
: 7. Remarks:
(10)                                                                                               (35)
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
(11)                                                                                               (36)   _________________________          4 (12)                                                                                               (37)
: 8. Nom. Thickness (In.)
I.
1.50 Min. design thickness (in.)
t*R\   ______________________________________________________
1.36 Dia. ID (ft & in.)
                                                                                                  --    I-(14)                                                                                              (39)                                         I (15)                                                                                              (40)
N/A Length overall (ft& in.)
I (16)                                                                                              (41)
N/A
_________________                    I (17)                                                                                              (42)
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number HT: 54682 S/N 1 National Board No.
I (18)                                                                                              (43)                                         4 (19)                                                                                              (44)
In Numerical Order N/A HT: 54682 SIN 2 N/A HT: 54682 SIN 3 N/A HT: 54682 S/N 4 N/A HT: 54682 S/N 5 N/A HT: 54682 S/N 6 N/A HT: 54682 S/ON 8 N/A HT: 54682 S/N 91/
__________________________          4.
I-Part or Appurtenance Serial Number (28)
(20)                                                                                              (45) 4.
(27)
(21)                                                                                              (46)     __________________________
(28)
__________________________          +
(29)
(22)                                                                                              (47)
(30)
(23)                                                                                              (48)
(31)
(24)                                                                                              (49)
(32)
(25)                                                                                              (50)
(33)
: 10. Design pressure                         1250               psi. Temp.               575
(34)
                                                                                                            "*F. Hydro. test pressure                         N/A                At temp. *F
(35)
                                                                                                                                                            *when applicable) 2 and 3 on this Data Report 1s
(36)
  -Supplemental   Information In the form of lists, sketches, or drawings may be used provided Ill size Is 0 'A x 11. (2) Information In Items Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(37) t*R\\
(1218)                                      This form (EO0040) may be obtained from the. Order Oept., ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.                       Reprin~t (TOII1I
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50) 1-I
*1
*1
_______________________ '1*
_________________________ 4 I.
I I
I I
4
__________________________ 4.
__________________________ 4.
__________________________ +
National Board No.
In Numerical Order
: 10. Design pressure 1250 psi.
Temp.
575
"*F. Hydro. test pressure
-Supplemental Information In the form of lists, sketches, or drawings may be used provided Ill size Is 0 'A x 11. (2) Information In Items 2 and 3 on this Data Report 1s Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
This form (EO0040) may be obtained from the. Order Oept., ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.
Pg. I of 2 (1)
(2)
(3)
-0)
(5)
(6)
(7).
(8)
(9)
(10)
(11)
(12)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
N/A
*when applicable)
At temp. *F
. Tjp (addenda date)
( class)
(1218)
Reprin~t (TO II1I


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.         HT: 54682 S/N 1           through         S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by                         N/A                         P.E. State        N/A          Reg. no.                        N/A (when applicable)
Certificate Holders' Serial Nos.
P.E. State       N/A           Reg. no.                         N/A Design report* certified by                            N/A (when appllcablel CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are cdrrect and that this (these)                                     Pilot Poppet conforms to the rules of construction of the ASME Code, Section I11,Division 1.
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)
NPT Certificate of Authorization No.                         N2607                         Expires                               6-13-04           a Date                                  Name              Atwood & Morrill Co., Inc.                   Signed                    /p14zt&
N/A (when appllcablel P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are cdrrect and that this (these) conforms to the rules of construction of the ASME Code, Section I11, Division 1.
(NPT Crtbfcate Holder)                                         (authorized representaibve)
NPT Certificate of Authorization No.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and'Pressure Vessel Inspectors and the State or Province of New York                    And employed by                                                 H.S.B.I & I. Co.
N2607 Expires Pilot Poppet 6-13-04 a
of               Hartford, CT                 have Inspected these Items described in this Data Report on                   ,7,     /       . and state that to the
Atwood & Morrill Co., Inc.
    ,st of my knowledge and belief, the Certificate   Holder has   fabricated these   parts or appurtenances in accord   rnce with   the ASME     Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
(NPT Crtbfcate Holder)
Signed
/p14zt&
(authorized representaibve)
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and'Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.
of Hartford, CT have Inspected these Items described in this Data Report on  
,7,  
/  
. and state that to the  
,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord rnce with the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions                                 1 Date                            Signed 11.11w - -- &#xfd;&#xfd;&d
Date Commissions  
                                                                                                                            */)&#x17d;,7e E               )-'n'
*/)&#x17d;,7e E 1)-'n'
                                                                          ;rspec"                                    [Nafn 6d. (mot.Enclosenemfft) and tautoOr pic. andn.
[Nafn 6d. (mot. Enclosenemfft) and tauto Or pic. and n.
Reg. no.
Reg. no.
N/A N/A Date Name New York
- 11.11 - --
w Signed
&#xfd;&#xfd;&d
;rspec"


FORM NR-1           REPORT OF REPAIR fl                   MODIFICATION El                     OR REPLACEMENT                     []
FORM NR-1 REPORT OF REPAIR fl MODIFICATION El OR REPLACEMENT []
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS 1.Work performed by       Continental Field Systems,                                 Inc                                     3218 (name of NR certificate holder)                                               (P.O. no., job no., etc.)
TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
93   West'gatP     Blvd-         Savannah, GA 31405 (address) 2.Owner       PPL LLC (name) 2 North Ninth Street,                     Allentown,               PA 18101 (address)
: 1.
: 3. Name, address and identification of nuclear power plant                 Susquehanna Steam Electric 5 Miles North of Berwick. PA                                         Salem.Twp, PA
Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
: 4. System 1-83                   HV141F028C                             Main Steam
(P.O. no., job no., etc.)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                           See Attached Identification                                                         Construction Code                               Activity Type of     Mfg.         Mfg. Nat'l Bd. Jurisd.           Other       Year         Name/           Edition/         Code         Code         Repair/
93 West'gatP Blvd-Savannah, GA 31405 (address) 2.Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
No     Item     Name       Serial No.     No.       No.                   Built       Section/         Addenda           Case(s)       Class           Mod/
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick. PA Salem.Twp, PA
Division                                                       Replace 2
: 4. System 1-83 HV141F028C Main Steam
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
Mfg.
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3 4
3 4
5 6
5 6
7 9
7 9
10
10
: 5. b: Items Installed During Replacement Activities               See At taizhed Identification                                                                 Construction Code Type of   Installed or. Mfg.       Mfg         Natl Bd.         Jurisd     Other         Year       Name/         Edition/               CodeCd Item       Replaced         Name     Serial No.       No.             No                     Built     Section/       Addenda                         ls Iaes 5a Item No.                                                                                   Division I              T        1              1                1          1          1            1            -t                              4 I                        1              1                4          4          4            4              +                +            4 I                4-      1              4                4          4-4                      4              +                +            I 4              4        4              4                4          4          4            4              4.              4-            L 4              1        1              4                4  -+                  4            4              +/-                +            4 t              I        t              4                4          4          4            4              +                +            4 4              4        +              4                4          4          4            4              4-              4-            4 4              4        4              4                4          1          4            4              4-              4-            4 I              T        4              4                4          4          4            4              4                4--          4 4              t        4              4                4          4          4            4              +              +              4
: 5. b: Items Installed During Replacement Activities See At taizhed Identification Construction Code Type of Installed or.
: 6. ASME Code Section XI applicable for inservice inspection:                 1989                           L.N/A                     N/A (edition)                     (addenda)                     (Code Cases(s))
Mfg.
: 7. ASME Code Section XI used for repairs, modifications, or replacements:                         1989                 N/A                       N/A (edition)         (addenda)                 (Code CaseS(s))
Mfg Natl Bd.
: 8. Construction Code used for repairs, modifications, or replacements:                                           A{L.N/A                         N/A (cditio             (addenda)                 (Code Cases(s))
Jurisd Other Year Name/
: 9. Design responsibilities: Atwood & Morrill Co.
Edition/
: 10. Tests conducted: hydrostatic lI pneumatic L] design pressure                   []       pressureN4A_           psi Code Case(s)
Code Cd Item Replaced Name Serial No.
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1"055 Crupper Ave., Columbus, OH 43229                                             Rev. 8
No.
: 11. Description of work:         RPP    AttnohPA (use of properly identified additional sheet(s)or sketch(es) is acceptable) 12.Remarks:     See attached manufacturer's                                 data report CERTIFICATE OF COMPLIANCE I, David McCathie                     certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section X) of the ASME Code and the National Board Inspection Code "NR" rules.
No Built Section/
National Board Certificate of Authorization No. NR-82                                 to use the "NR" stamp expires 5 /25                       2003 NR Certificate Holder Continenta Ield                           Syst P                 nc.
Addenda Iaes ls 5a Item No.
Date 61           90n       Signed       .C-e)                         Wm-                               lniyrat.                           A2ae (authorized representative)                                           (title)
Division
CERTIFICATE OF INSPECTION I, WILLIAM 'e '906CTS                holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of N*NSYL VAN4V/4                                               and employed by R~cmprj MuTLm.IA rsum                     Heir COA               ,t74V                   of Z-0$ImcON. leI                                           have inspected the repair, modification or replacement described in this report on 4, I                                 , Z 00 Z and state that to the best of my knowledge and belief, this repair, modification or r'eplacement activity has been completed in accordance with Section XI of the ASME Codg&#xfd; and the National Board Inspection Code "NR" rules.
: 6. ASME Code Section XI applicable for inservice inspection:
1989 L.N/A N/A (edition)
(addenda)
(Code Cases(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:
1989 N/A N/A (edition)
(addenda)
(Code CaseS(s))
: 8. Construction Code used for repairs, modifications, or replacements:
A{L.N/A N/A (cditio (addenda)
(Code Cases(s))
: 9. Design responsibilities:
Atwood & Morrill Co.
: 10. Tests conducted: hydrostatic lI pneumatic L] design pressure []
pressureN4A_
psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1"055 Crupper Ave., Columbus, OH 43229 Rev. 8 I
T 1
1 1
1 1
1
-t 4
I 1
1 4
4 4
4
+
+
4 I
4-1 4
4 4-4 4
+
+
I 4
4 4
4 4
4 4
4
: 4.
4-L 4
1 1
4 4
-+
4 4
+/-
+
4 t
I t
4 4
4 4
4
+
+
4 4
4
+
4 4
4 4
4 4-4-
4 4
4 4
4 4
1 4
4 4-4-
4 I
T 4
4 4
4 4
4 4
4--
4 4
t 4
4 4
4 4
4
+
+
4
: 11. Description of work:
(use of properly identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks:
See attached manufacturer's data report CERTIFICATE OF COMPLIANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section X) of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
NR-82 to use the "NR" stamp expires 5 /25 2003 NR Certificate Holder Continenta Ield Syst P nc.
Date 61 90n Signed  
.C-e)
Wm-lniyrat.
A2ae (authorized representative)
(title)
CERTIFICATE OF INSPECTION I, WILLIAM 'e '906 CTS holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of N*NSYL VAN4V/4 and employed by R~cmprj MuTLm.IA rsum Heir COA  
,t74V of Z-0$ImcON.
leI have inspected the repair, modification or replacement described in this report on 4,
I  
, Z 00 Z and state that to the best of my knowledge and belief, this repair, modification or r'eplacement activity has been completed in accordance with Section XI of the ASME Codg&#xfd; and the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury property damage or loss of any kind arising from or connected with this inspection.
DateJ'V"'( Z4         O*O_1 Signed4,,J                 i 7el,r"           -- 7Tr-           CommissionsUB79BOA.-t, JAM P*,                           o4 (Inspector)*         -              (National Board (ind.endorsements), jur"idiction, and no.)
DateJ'V"'( Z4 O*O_ 1 Signed4,,J i
7el, r"  
-- 7Tr-CommissionsUB79BOA.-t, JAM P*,
o4 (Inspector)*
(National Board (ind. endorsements), jur"idiction, and no.)
RPP AttnohPA


Form NR-I Attachment                                              Report of Repair / Replacement Worked Performed by Continental Field Systems                                                   Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C Items Which Required Repair, Modification, or Replacement Activities Identification                                                                                                                       Code No         Type of Item       Mfg. Name   Mfg   Serial   Nat'l Bd. Jurisdiction                                                           Construction Code tAner     Year     Name/ Section/     Edition / Construction Code     Code Class       Repair/
Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C Items Which Required Repair, Modification, or Replacement Activities Identification No Type of Item Mfg. Name Mfg Serial Nat'l Bd.
                                              #            No.            No.                      Built        Division        Addenda          Case(s)                     Replace 1           MSIV               A&M       7-221           N/A           N/A           N/A       1974     ASME III/NB       1971/S71         1535-2       1           Repair 2
Jurisdiction No.
Items Installed During Replacement Activities Identification Item           Installed/     MFG.       Mfg. Serial         Nat'l       Jurisd. No. Other     Year Built     Name/             Edition/       Code         Code Replaced       Name             No.         Bd. No.                                                 Section/           Addenda       Case(s)       Class Poppet         Replaced         WSI                                                                                 Division 2           N/A             N/A         N/A         2001           III NB         71 Ed. $71 A   N/A             I Bonnet           Replaced       A&M               6           N/A             N/A         N/A         2001           III NB         71 Ed. S71 A   N/A             I Pilot Poppet         Replaced       A&M               6           N/A             N/A         N/A         2001           III NB       71   Ed. S71 A   N/A             I Super Nuts         Replaced       A&M         NU-01017           N/A             N/A         N/A         2002           Ill NB       71   Ed. S71 A   N/A             I
No.
                                                                                                                                                                          '      f2
Job Number 3218 tAner Year Built Name/ Section/
Division Edition /
Addenda Construction Code Code Code Class Case(s)
Repair/
Replace 1
MSIV A&M 7-221 N/A N/A N/A 1974 ASME III/NB 1971/S71 1535-2 1
Repair 2
Items Installed During Replacement Activities Identification f 2 Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced WSI 2
N/A N/A N/A 2001 III NB 71 Ed. $71 A N/A I
Bonnet Replaced A&M 6
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Pilot Poppet Replaced A&M 6
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 Ill NB 71 Ed. S71 A N/A I
Construction Code Form NR-I Attachment


Form NR-1 Attachment                                         Report of Repair / Replacement Worked Performed by Continental Field Systems                                           Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 1h St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C
Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 1h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C
: 6. ASME Code Section Xl applicable for inservice inspection: 1989                   N/A            N/ A (edition)          (addenda)      (C ode Case(s))
: 6. ASME Code Section Xl applicable for inservice inspection: 1989 (edition)
: 7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989             N/A              N/A (edition)        (addenda)        (Code Case(s))
: 7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989 (edition)
: 8. Construction Code used for repairs, modifications, or replacements:     1971             Summer 71       I (edition)         (addenda)       Code Case
: 8. Construction Code used for repairs, modifications, or replacements:
1971 (edition)
Report of Repair / Replacement Job Number 3218 N/A N/
(addenda)
(C N/A (addenda)
Summer 71 (addenda)
A ode Case(s))
N/A (Code Case(s))
I Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted       N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
Line 2,116: Line 4,200:


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of         2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. I of 2
: 1.     Manufactured and certified by                               Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and (name          address or and address      NPT Caflitsolu Holder) of NPT CereitScale HoMAer)
: 1.
Atwood & Morril Co. 285 Canal Street. Salem, MA 01970
Manufactured and certified by
: 2.      Manufactured for                                                            (name and address of Purchaser)
: 2.
: 3.      Location of installation                                    PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
Manufactured for
SA 105 Gr.11                     70.0 Ksi                                     N/A                                     2001
: 3.
: 4.      Type:      A &MDwg D-32467-622 R/7 (drawing no.)           (mall. spec. no.)             (tensile strength)                               (CRN)                                 (year buill)
Location of installation Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address or NPT Caflitsolu Holder)
: 5.     ASME Code, Section III, Division 1:                 1971                       S 1971                                   1                                   N/A (edition)               (addenda dale)                             (class)                         (Code Case no.)
(name and address of NPT CereitScale HoMAer)
: 6.     Fabricated'in accordance with Const. Spec. (Div. 2 only)                       N/A                 Revision                   N/A                 Date               NIA (no.)
Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)
II
PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)
: 7.     Remarks:       21" MSIV Valve Poppet SA 105 Gr.II with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 for SA 105 Gr.
: 4.
21 Heat #s 00-21-01, 00-21-05.00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite Min. design thickness (in.)    NIA                Dia. ID (ft &in.)      21-Nom.
Type:
00              Length overall (ft & in.)            31"
A & M Dwg D-SA 105 Gr.11 70.0 Ksi N/A 2001 32467-622 R/7 (drawing no.)
: 8.     Nom. Thickness (in.)       N/A
(mall. spec. no.)
: 9.     When applicable, Certificate Holder's Data Reports are attached for each item of t" National                                      Pad or Appurtenance                                    National Part or Appurtenance                                                                       Serial Number                                     Board   No.
(tensile strength)
Serial Number                       Board No.                                                                                       In Numerical Order In Numerical Order (1)   245951-1                                                                  (28)                                                 4.
(CRN)
1-                                         (27)
(year buill)
  &#xfd;,2)         245951-2                                                                                                                      +
: 5.
245951-245951.-4                                                                  (28)    _________________________________ +
ASME Code, Section III, Division 1:
(3) 245951-5                                                                  (29)                                                +
1971 S 1971 1
N/A (edition)
(addenda dale)
(class)
(Code Case no.)
: 6.
Fabricated'in accordance with Const. Spec. (Div. 2 only)
N/A Revision N/A Date NIA (no.)
: 7.
Remarks:
21" MSIV Valve Poppet SA 105 Gr.II with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 for SA 105 Gr. II Heat #s 00-21-01, 00-21-05.00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21
: 8.
Nom. Thickness (in.)
N/A Min. design thickness (in.)
NIA
: 9.
When applicable, Certificate Holder's Data Reports are attached for each item of t" Dia. ID (ft &in.)
21-Nom.
Length overall (ft & in.)
31" 00 Part or Appurtenance Serial Number 245951-1 1-245951-2 245951-245951.-4 245951-5 245951-7 245951-8 245951-9 National Board No.
In Numerical Order Pad or Appurtenance Serial Number (28)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(38)
_________________________________ 4.
+
_________________________________ +
+
_________________________________ 4
_________________________________ 4 4
I 4
_________________________________ 4 1.
National Board No.
In Numerical Order I
t.)
: 10. - Design pressure N/A psi.
Temp.
N/A (40)
(41)____________
(42)
(43)
(44)
(45)
(46)_______________
(47)
(48)
(49)
(50)
*F Hydro. test pressure N/A (when applicable)
*Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 1A x 11, (2) information in items 2 and 3 on this Data Report is included ori each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form, (12/88)
This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300.
Reprint (7/91) lVibrary svrV.ualitya Ptroject FlestAtwood & MornlA2001L31140 )Oct 2001)W2-31140.doc (1)  
&#xfd;,2)
(3)
(4)
(4)
(5)   245951-7                                                                  (30)    _________________________________ 4 (6)   245951-8                                                                  (31) _________________________________ 4            4 (7)  245951-9                                                                  (32) _________________________________
(5)
(33)
(6)
(7)
(8)
(8)
(34)
(9)
(9)
(10)                                                                               (35) _______________________________________________________________________
(10)
I (11)                                                                               (36) ______________________________________________________
(11)
4 (12)                                                                               (37) _________________________________ 1.            4
(12)  
      *1'13'l                                                                             (38)
*1'13'l (14)
-  I I    (13)"w~                                I                                          t.)      _____________________________                  ____________________________
(14)
(40)
(15)
(15)
(41)____________                                _
(16)
(16)
(42)
(17)
(17)
(43)    _______________
(18)
(18)
(44)    _    _      _    _      _      _    _
(19)
(19)
(20)
(20)
(45)
(46)_______________                              _
(21)
(21)
(22)                                                                              (47)
(22)
(48)
(23)
(23)
(49)
(24)
(24)
(50)
(25) at temp. 'F (13)"w~
(25)
I I
                                                                                                              *F      Hydro. test pressure                    N/A              at temp. 'F N/A                    psi. Temp.          N/A                                                      (when applicable)
: 10. - Design pressure 1
used provided (1) size is 8 A x 11, (2) information in items 2 and 3 on this
    *Supplemental information in the form of lists, sketches, or drawings may be sheets is recorded at the top of this form, Data Report is included ori each sheet, (3) each sheet is numbered and the number of Drive, Box 2300. Fairfield. NJ 07007-2300.
(12/88)                                  This form (E00040) may be obtained from the Order Dept., ASME 22 Law                                                              Reprint (7/91) lVibrary svrV.ualityaPtroject FlestAtwood & MornlA2001L31140 )Oct 2001)W2-31140.doc


FORM N-2 (Back - Page 2 of 2 Certificate Holder's Serial Nos. HI # 245951           through       1,2.4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by                         Boyd P. Brooks                         P.E. State               CA           Reg. No.1           13655 (when applicable)
FORM N-2 (Back - Page 2 of 2 Certificate Holder's Serial Nos.
Design Report* certified by                             Herbert Cook                             P.E. State               MA           Reg. No.,           10981 (when applicable)
HI # 245951 through 1,2.4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by Boyd P. Brooks P.E. State CA Reg. No.1 13655 (when applicable)
CERTIFICATE OF COMPLIANCE                                         .
Design Report* certified by Herbert Cook P.E. State MA Reg. No.,
We certify that the statements made in this report are correct and that this (these)           21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
10981 (when applicable)
NPT Certificate of Authorization No.       N-2873                                                           x ires     Nave     r 13,2004 Date     12-10-01               Name       Welding Services Inc.                             Sig net-                           Lu (NPT Certificate Holder)                                             (authorized representative)
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section III, Division 1.
CERTIFICATE OF INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia                                                                   and employed by         The Hartford Steam Boiler Inspection and Insurance Co.
NPT Certificate of Authorization No.
of     Hartford. CT                     have inspected these items described in this Data Report on             December 10, 2001               and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section III, Division 1. Each part listed. has been authorized for stamping on the-date shown above.
N-2873 x ires Nave r 13,2004 Date 12-10-01 Name Welding Services Inc.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected i is ins :ifon.
Sig net-Lu (NPT Certificate Holder)
wo .IV -\
(authorized representative)
* IA*
CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.
Date     12-10-01           Signed and slate or prov. and no.]
of Hartford. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section III, Division 1. Each part listed. has been authorized for stamping on the-date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected i
is ins :ifon.
wo.I V
* -\\
IA*
Date 12-10-01 Signed and slate or prov. and no.]
WLJbrary_svrlquality_alProjecf FiesrAtwood & Mor7*l200 131140 )Oct 2001)W2-31140.doc
WLJbrary_svrlquality_alProjecf FiesrAtwood & Mor7*l200 131140 )Oct 2001)W2-31140.doc


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                               Pg. 1 of 2
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
: 1. Manufactured and certified by             Atwood & Morrill Co., Inc. 285 Canal Street                             Salem, MA 01970 (name and address or mri Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address or mri Certificate Holder)
: 2. Manufactured for         Pennsylvania Power & Light                     Berwick, PA 18603 iname and aootres of PurCnaser'
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 iname and aootres of PurCnaser'
: 3. Location of installation           Suscuehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and mddress)
: 3. Location of installation Suscuehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and mddress)
: 4. Type:           *32162-409-D Rev. 1                       SA 105 GR II                    77.900 PSI                                N/A                          2001 (drawing no.)                         105 SA(marL      GR 11
: 4. Type:  
                                                                      .eape no.)                Pens"l stength)                                                      (y-a Wtl
*32162-409-D Rev. 1 (drawing no.)
: 5. ASME Code, Section III, Division 1:                         1971                        S71                              1                                N/A
: 5. ASME Code, Section III, Division 1:
                                                                                                                                                                      -. 9 vaee Case no.A SOC (edmon)               (aodenaa oate)                     tclass,                        (Code N/A            Revision              N/A              Date                  N/A
SA 105 GR II (marL.eape no.)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only) 7 Rno.4
1971 (edmon) 77.900 PSI Pens"l stength)
: 7. Remarks:       Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M PIN 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME
S71 (aodenaa oate)
        *pr*inn III 1.(:71 Frlitinn imtmmpr 1971 addenda
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 8. Nom. Thickness (in.)           5.312       Min. design thickness (tn.)         5.094       Dia. ID (ft & in.)         N/A         Length overall (ft& In.)           N/A
N/A Revision N/A Date 7 Rno.4
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M PIN 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME
*pr*inn III 1.(:71 Frlitinn imtmmpr 1971 addenda
: 8. Nom. Thickness (in.)
5.312 Min. design thickness (tn.)
5.094 Dia. ID (ft & in.)
N/A Length overall (ft& In.)
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:
Part or Appurtenance                         National                              Part or Appurtenance                                National Serial Number                           Board No:                                   Serial Number                                  Board No.
Part or Appurtenance National Serial Number Board No:
In Numerical Order                                                                        In Numerical Order (1)   HT: H3391 SIN 4                               N/A                           (25)
In Numerical Order (1)
(2)    HT: H3391 S/N 5                               N/A                           (27) l(3)     HT: H3391 S/N 6                               N/A                           (28)
HT: H3391 SIN 4 N/A (2)
                                                                                                                                    *i.
HT: H3391 S/N 5 N/A l(3)
(4)                                                                               (29) 4 (5)                                                                               (30) 4 (6)                                                                               (31)
HT: H3391 S/N 6 N/A (4)
M                                                                                  (32)
(5)
(8)                                                                               (33)
(6)
(1)                                                                               (34)
M (8)
                                                                                          .(35)
(1)
(11)  ____________________________                                                  (36)
(11)
(12)                                                                                (37)
(12)
                                                                                        -(38Y (14)                                                                                (39)
(14)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
Part or Appurtenance Serial Number (25)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
(34)  
.(35)
(36)
(37)  
-(38Y (39)
(40)
(40)
(16)                                                                                (41)
(41)
(17)                                                                                (42)
(42)
(18)                                                                                (43)
(43)
(19)                                                                                (44)
(44)
(20)                                                                                (45)
(45)
(21)                                                                                (46)
(46)
(22)                                                                                (47)
(47)
(23)                                                                                (48)
(48)
(24)                                                                                (49)
(49)
(25)                                                                                (50)
(50)
I
*i.
: 0. Design pressure                                                         575         *F. Hydro. test pressure                         N/A                At temp. *F 1250          psi. Temp.
4 4
(when applicable)
I National Board No.
"Supplemental Information In the form of lits, sketches, or drawings may be used provided (1) size Is 8 V, x 11, (2) Information In items 2 and 3 on this Data Report is Included on each sheet Is numbered and the number of sheets is recorded at the top of this form.
In Numerical Order
(Ives)                              This form (E00040) may be obtained from the Order DepL. ASME. 22 Low Drive,. Box 2300. Fairfield, NJ 07007.2300.
: 0. Design pressure 1250 psi.
Temp.
575
*F. Hydro. test pressure "Supplemental Information In the form of lits, sketches, or drawings may be used provided (1) size Is 8 V, x 11, (2) Information In items 2 and 3 on this Data Report is Included on each sheet Is numbered and the number of sheets is recorded at the top of this form.
This form (E00040) may be obtained from the Order DepL. ASME. 22 Low Drive,. Box 2300. Fairfield, NJ 07007.2300.
Reprint (71 91)
Reprint (71 91)
Pg. 1 of 2 N/A 1
2001
: tclass, (y-a Wtl N/A vaee SOC -. 9 (Code Case no.A N/A N/A (when applicable)
At temp. *F SA 105 GR 11 (Ives)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.             HT: H3391         SIN 4           through         S/N 6 CERTIFICATION OF DESIGN N/A                           P.E. State          N/A            Reg. no.                          N/A Design specifications certified by (when applicable)
Certificate Holders' Serial Nos.
P.E. State           N/A           Reg. no.                           N/A Design report
HT: H3391 SIN 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by Design report
* certified by                          N/A (when applicable)
* certified by N/A (when applicable)
CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these)                                                 Cover conforms to the rules of construction of the ASME Code, Section II1,Division 1.
N/A (when applicable)
NPT Certificate of Authorization No.                         N2607                           Expires                                   6-13-04              ,1)
P.E. State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section II1, Division 1.
Name              Atwood & Morrill Co., Inc.                       Signed   ./:
NPT Certificate of Authorization No.
Date                                                                                                                                    (a-P       represntative (NPT Cef0lmiat Holder)
Date Name N2607 Expires Atwood & Morrill Co., Inc.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York                    And employed by                                                     H.S.B.I& I. Co.
(NPT Cef0lmiat Holder)
bf                   Hartford, CT               have inspected these items described in this Data Report on                   /.1                       , and state that to the these   parts or appurtenances   in accordance-with       the ASME     Code, Section rst of my knowledge and belief, the Certificate Holder has fabricated
Signed  
    .. Division 1. Each part listed has been authorized for stamping on the date shown above.
./:
(a-P represntative CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I& I. Co.
bf Hartford, CT have inspected these items described in this Data Report on  
/.1  
, and state that to the rst of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance-with the ASME Code, Section  
.. Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date           //     &#xfd;7l      Signed   _    _    _          _      _    _    _      _    __Commissions               VyJ&#xfd;5         ,Ze.
Date  
II  /I.                        ,  --          (authorized map="t                                       [Natl ad. ('icl. Endo~rsernard   and state or pmov.and no.l
//  
&#xfd;7 l Signed
__Commissions VyJ&#xfd;5  
,Ze.
Reg. no.
Reg. no.
N/A N/A Cover New York (authorized map="t 6-13-04
,1)
I I
/I.
[Natl ad. ('icl. Endo~rsernard and state or pmov. and no.l


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                             Pg. 1 of 2 Manufactured and certified by                 Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 inaame   and address of NPT Certificate Holder)
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2 Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 inaame and address of NPT Certificate Holder)
: 2. Manufactured for             Pennsylvania Power & Light
: 2. Manufactured for Pennsylvania Power & Light
* Berwick, PA 18603 (name and address of Purchaser)
* Berwick, PA 18603 (name and address of Purchaser)
: 3. Location of installation                 Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 iname and address)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 iname and address) 5.700 PSI N/A 2001
A      'r,*.              *13Aa    _C1'2 r            " ('I                                              5.700 PSI                             N/A                       2001
-ma v
-.   ,)p,=.                        -.        .
I.Ss v
                                        *f.HqA   -ma                        , v I.Ss A7930     Wv              . 5q. 70
W
                                                                                                              .    . PSIV'*
*f.HqA A7930 5q. 70 PSIV'*
(drawing no.)                         (marl Spec7. no.)                                                        * .... W
(drawing no.)
                                                                    -1074                        A71                                                              N/A
: 5. ASME Code, Section III, Division 1:
: 5. ASME Code, Section III, Division 1:
: 1.   ,0.
(marl Spec7. no.)
se 1ICoeI (edition)                 (addenda date)                   (class)                       (Code Catso no.)
-1074 A71 1.
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                                 N/A           Revision           N/A             Date                   N/A (no)
N/A 1 ICoeI se
: 7. Remarks:                 Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA ASME (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of Section III 1971 Edition Summer 1971 addenda
,0.
: 8. Nom. Thickness (in.)                 1.50         Min. design thickness (in.)           1.36         Dia. ID (ft & in.)       N/A       . Length overall (ft& in.)         N/A
(edition)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report National                                Part or Appurtenance                              National Board  No.
(addenda date)
Part or Appurtenance                                                                           Serial Number Serial Number                              Board No.                                                                              In Numerical Order In Numerical Order (261 (1)      HT:   54682     S/N     1                   N/A (27)
(class)
(2)      HT:   54682     S/N     2                   N/A
(Code Catso no.)
                                                                                                  .(28)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(3)      HT:   54682     S/N     3                   N/A (29)
N/A Revision N/A Date N/A (no)
(4)      HT:   54682     S/N     4                   N/A N/A                             (30)
: 7. Remarks:
(5)      HT:   54682     S/N     5 (31) 11(6)        HT:   54682     S/N     6                   N/A (32)
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
(7). HT:
: 8. Nom. Thickness (in.)
HT:   54682 54682     S/N S/N     89                  N/A N/A                            (33)
1.50 Min. design thickness (in.)
(8)
1.36 Dia. ID (ft & in.)
N/A  
. Length overall (ft& in.)
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance Serial Number HT: 54682 S/N 1 National Board No.
In Numerical Order N/A HT: 54682 S/N 2 N/A HT: 54682 S/N 3 N/A HT: 54682 S/N 4 N/A HT: 54682 S/N 5 N/A HT: 54682 S/N 6 N/A HT: 54682 S/N 8 N/A HT: 54682 S/N 9 N/A Part or Appurtenance Serial Number (261 (27)
.(28)
(29)
(30)
(31)
(32)
(33)
(34)
(34)
(9)
(35)
(35)
(10)
(36)
(36)
(37)                               -4 (12)
(37)
(14)                                                                                    (39)
-4 (39)
(40)
(40)
(16)                                                                                   (41) i (42)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
National Board No.
In Numerical Order
: 0. Design pressure 1250 psi.
Temp.
575 "F. Hydro. test pressure "Supplemental Information In the form of lists, sketches. or drawings maybe used provided (I) size Is 111A x 11, (2) Information In itsms 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(I21i/)
This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive. Box 2300, Fairfield, NJ. 07007.2300.
Reprint (7!91)
A
'r,*.
*13Aa
_C1'2 r
" ('I (1)
(2)
(3)
(4)
(5) 11(6)
(7).
(8)
(9)
(10)
(12)
(14)
(16)
(17)
(17)
(18)                                                                                      (43)
(18)
(19)                                                                                    (44)
(19)
(20)                                                                                    (45)
(20)
(21)                                                                                    (46)
(21)
(22)                                                                                    (47)
(22)
(23)                                                                                    (48)
(23)
(24)                                                                                    (49)
(24)
(50)
(25)
(25)
                                                                                                      "F. Hydro.      test pressure                    N/A           At temp. "F
N/A (when applicable)
: 0. Design pressure                      1250            psi. Temp.                575                                                  (when applicable)
At temp. "F i
Information In itsms 2 and 3 on this Data Report Is "Supplemental Information In the form of lists, sketches. or drawings maybe used provided (I) size Is 111Ax 11, (2)
,)p,=.
Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
W
This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive. Box 2300, Fairfield, NJ. 07007.2300.             Reprint (7!91)
(I21i/)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.       HT: 54682 S/N 1           through       S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by                         N/A                         P.E. State     N/A         Reg. no.                         N/A when appicabe)
Certificate Holders' Serial Nos.
Design report certified by                            N/A                              P.E. State      N/A         Reg. no.                         N/A (when applicable)
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A when appicabe)
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)                                 Pilot Poppet conforms to the rules of construction of the ASME Code, Section III, Division 1.
N/A (when applicable)
NPT Certificate of Authorization No.                       N2607                        Expires                            6-13-04          ,
P.E. State N/A P.E. State N/A Reg. no.
Date             /Name                 Name            Atwood & Morrill Co.. Inc.                 Signed   A~a-(NPT Cartficate Heldwo                                      (audtnized repreasenb.)
N/A Reg. no.
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York                    And employed by                                             H.S.B.I & I. Co.
N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
of               Hartford, CT                 have inspected these Items described in this Data Report on           4;7,,V7,, /           , and state that to the est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordincerwith the ASME Code, Section
Pilot Poppet NPT Certificate of Authorization No.
  . Division 1. Each part listed has been authorized for stamping on the date shown above.
Date  
/Name N2607 Expires Atwood & Morrill Co.. Inc.
(NPT Cartficate Heldwo 6-13-04 Signed A~a-(audtnized repreasenb.)
CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.
of Hartford, CT have inspected these Items described in this Data Report on 4;7,,V7,,  
/  
, and state that to the est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordincerwith the ASME Code, Section  
. Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date     4/47ige 74-           Signed f
Date 4/47ige
K1                        Comm issions   ,1X-5 70       e        e-'
&#xfd;Pttonzed inpeot'
74-K1 Comm issions  
,1X-5 e
70 e-'
(Nail Bd. rind. Endorazmerne) and slte or prov. and no.)
(Nail Bd. rind. Endorazmerne) and slte or prov. and no.)
                                                              &#xfd;Pttonzed inpeot'
New York Name f
Signed


FORM NR-1         REPORT OF REPAIR EX                   MODIFICATION El                       OR REPLACEMENT TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
FORM NR-1 REPORT OF REPAIR EX MODIFICATION El OR REPLACEMENT TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS
: 1. Work performed by       Continental Field Systems,                               Inc                                 3218 (name of NR certificate holder)                                             (P.O. no., job no., etc.)
: 1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)
23 Westgate Blvd.                 Savannah,           GA 31405 (address)
(P.O. no., job no., etc.)
: 2. Owner           PPL LLC (name) 2 North Ninth Street,                     Allentown,               PA 18101 (address)
23 Westgate Blvd.
: 3. Name, address and identification of nuclear power plant             Susquehanna Steam Electric 5 Miles NoEth of Berwick, PA                                               SalemTwp.PA
: Savannah, GA 31405 (address)
: 4. System I -8                 HV141FO2R8D                             Mainqteamrn
: 2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
: 5. a: Items Which Required Repair, Modification, or Replacement Activities                             See Attached Identification                                                           Construction Code                           Activity Type of     Mfg.     Mfg.     Nat'l Bd. Jurisd.       Other       Year         Name/           Edition/       Code           Code         Repair/
: 3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles NoEth of Berwick, PA SalemTwp.PA
No Item           Name     Serial No. No.       No.                   Built         Section/       Addenda       Case(s)         Class         Mod/
: 4. System I -8 HV141FO2R8D Mainqteamrn
Division                                                   Replace 2
: 5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.
3
Mfg.
                '4 5
Nat'l Bd. Jurisd.
Other Year Name/
Edition/
Code Code Repair/
No Item Name Serial No.
No.
No.
Built Section/
Addenda Case(s)
Class Mod/
Division Replace 2
3  
'4 5
6 7
6 7
8 9
8 9
10 11 12
10 11 12
: 5. b: Items Installed During Replacement Activities                   See Attached Identification                                                                 Construction Code Type of     Installed or. Mfg.         Mfg       Nat) Bd.         Jurisd     Other         Year       Name/       Edition/           Code Code Item       Replaced     Name     Serial No.       No.             No                     Built     Section/   Addenda Case(s) Class 5a Item No.                                                                                 Division
: 5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.
: 6. ASME Code Section XI applfcable for inservice inspection:             I9898 (edition)
Mfg.
N /A A            .                N (addenda)                   (Code Caes(s))
Mfg Nat) Bd.
: 7. ASME Code Section XI used for repairs, modifications, or replacements:                       1989                     NXLA                       NIA (edition)       (addenda)               (Code Cas(s))
Jurisd Other Year Name/
: 8. Construction Code used for repairs, modifications, or replacements:                       1971                         71S7I                   NIA (edition)           (addenda)               (Code Cases(s))
Edition/
: 9. Design responsibilities:   Atwood & Morrill Co.
Code Code Item Replaced Name Serial No.
: 10. Tests conducted: hydrostatic L] pneumatic DI design pressure EI                         pressure*ILA_         psi Code Case(s)
No.
This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229                                             NB-81 Rev. 8
No Built Section/
: 11. Description of work:              See Attached (use Attahed Drycriptionsofowork:e (s. of properly identified additional sheet(s) or skelch(es) is acceptable)
Addenda Case(s) Class 5a Item No.
: 12. Remarks:            See Attached Manufacturer's                                       Data Report CERTIFICATE OF COMPLIANCE I,   David McCathie                       certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
Division
National Board Certificate of Authorization No.                   MR-8 6                   to use the "NR" stamp expires 5/25 ,2003 NR Certificate Holder     Continental Field                         Systems,,             Inc Dat*     .JI.       2.0_02Signed           Cag.                         (_        L                      -me)Q.
: 6. ASME Code Section XI applfcable for inservice inspection:
Quality         Control Manager (authorized representative)                                                 (title)
I 989 8
CERTIFICATE OF INSPECTION I, WU.-WM           "Z   6-C5 M. holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of [CH $SJ.                                 V4,W414                       and employed by FAcrtory Muru/L. Zv*IV                        tu,c           Cotoy',evy                     of J oI4P4.,ro                   eI                   _      have inspected the repair, modification or replacement described in this report on                             * -. IL2 ,                .p._and       state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Cod&0and the National Board Inspection Code "NR" rules.
N A
N
/A (edition)
(addenda)
(Code Caes(s))
: 7. ASME Code Section XI used for repairs, modifications, or replacements:
1989 NXLA NIA (edition)
(addenda)
(Code Cas(s))
: 8. Construction Code used for repairs, modifications, or replacements:
1971 71S7I NIA (edition)
(addenda)
(Code Cases(s))
: 9. Design responsibilities:
Atwood & Morrill Co.
: 10. Tests conducted: hydrostatic L] pneumatic DI design pressure EI pressure*ILA_
psi Code Case(s)
NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8
 
(s.
Drycriptionsofowork:e Attahed (use of properly identified additional sheet(s) or skelch(es) is acceptable)
See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I,
David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.
National Board Certificate of Authorization No.
MR-8 6 to use the "NR" stamp expires 5/25,2003 NR Certificate Holder Continental Field Systems,, Inc Dat*.JI.
2.0_02Signed Cag.  
-me)Q.
(_
L Quality Control Manager (authorized representative)
(title)
CERTIFICATE OF INSPECTION I, WU.-WM Z
6-C5 M. holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of [CH $SJ.
V4,W414 and employed by FAcrtory Muru/L. Zv*I V tu,c Cotoy',evy of J oI4P4.,ro eI have inspected the repair, modification or replacement described in this report on  
-. IL2  
.p._and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Cod&0and the National Board Inspection Code "NR" rules.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.
Date J"-W/ Z4 Z 0QZ Signed.                                   V       ,,,&.A- =                   CommissionsWU87 9 60Ar*., RV4JPFA ZC2O o.pe~                                 (Natio... .oad.(.   . edre.    . et) ju dcinadn.
Date J"-W/ Z4 Z 0QZ Signed.
(-spect*                              (National Board (incl. endorsements), Nui~ictiom and no.)
V  
,,,&.A-  
=
CommissionsWU87 9 60Ar*.,
RV4JP FA ZC2O o.pe~
(Natio....oad.(.
edre et) ju dcinadn.
: 12. Remarks:
See Attached work:
: 11. Description of (National Board (incl. endorsements), Nui~ictiom and no.)
(-spect*


Form NR-1 Attachment                                   1%        Report of Repair / Replacement 41 Worked Performed by Continental Field Systems, Inc.                                               Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D Items Which Required Repair, Modification, or Replacement Activities Identification                                                                                                         k_-onst ucton Code No       Type of Item         Mfg. Name   Mfg. Serial     Nat'l Bd. Jurisdiction       Other     Year     Name/ Section/     Edition /         Code     Code Class     Repair/
Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.
                                                #            No.           No.                       Built       Division       Addenda         Case(s)                 Replace I           MSIV               A&M         8-221           N/A           N/A           N/A       1974     ASME Ill/NB       1971/S71         1535-2       I         Repair 2
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D Items Which Required Repair, Modification, or Replacement Activities Identification 1%
Items Installed During Replacement Activities Identification                                                                                                         Construction Code Item           Installed/     MFG.       Mfg. Serial         Nat'l       Jurisd. No. Other     Year Built     Name/             Edition/       Code       Code Replaced       Name             No.         Bd. No.                                                 Section/         Addenda       Case(s)     Class Division Poppet           Replaced       A&M               6           N/A             N/A         N/A         2001         Ill NB       71 Ed. S71   A   N/A           I Bonnet           Replaced       A&M               2           N/A             N/A         N/A         2001           III NB       71 Ed. S71   A   N/A           I Pilot Poppet         Replaced       A&M               2           N/A             N/A         N/A         2001         III NB       71 Ed. S71   A   N/A           I Super Nuts         Replaced       A&M       NU-0 1017           N/A             N/A         N/A         2002         III NB       71 Ed. S71   A   N/A           I 1 of 2
41 Report of Repair / Replacement Job Number 3218 k_-onst ucton Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.
Jurisdiction Other Year Name/ Section/
Edition /
Code Code Class Repair/
No.
No.
Built Division Addenda Case(s)
Replace I
MSIV A&M 8-221 N/A N/A N/A 1974 ASME Ill/NB 1971/S71 1535-2 I
Repair 2
Items Installed During Replacement Activities Identification Construction Code Item Installed/
MFG.
Mfg. Serial Nat'l Jurisd. No.
Other Year Built Name/
Edition/
Code Code Replaced Name No.
Bd. No.
Section/
Addenda Case(s)
Class Division Poppet Replaced A&M 6
N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I
Bonnet Replaced A&M 2
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Pilot Poppet Replaced A&M 2
N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I
Super Nuts Replaced A&M NU-0 1017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I
1 of 2


Form NR-1 Attachment                                        Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.                                     Job Number 3218 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North   9 th St. , Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D
Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.
: 6. ASME Code Section XI applicable for inservice inspection: 1989                 N/A            N/ A (edition)          (addenda)      (Ciode Case(s))
23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D
: 7. ASME Code Section XI used for repairs, modifications, or replacements: 1989             N/A              N/A (edition)        (addenda)        (Code Case(s))
: 6. ASME Code Section XI applicable for inservice inspection: 1989 (edition)
: 8. Construction Code used for repairs, modifications, or replacements:     1971             Summer 71       I (edition)         (addenda)       Code Case
: 7. ASME Code Section XI used for repairs, modifications, or replacements: 1989 (edition)
: 8. Construction Code used for repairs, modifications, or replacements:
1971 (edition)
Job Number 3218 N/A N/
(addenda)
(Ci N/A (addenda)
Summer 71 (addenda)
A ode Case(s))
N/A (Code Case(s))
I Code Case
: 9. Design Responsibilities: Atwood & Morrill
: 9. Design Responsibilities: Atwood & Morrill
: 10. Test Conducted         N/A
: 10. Test Conducted N/A
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Ir replace with new components from OEM as part of valve enhancement.
: 11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Ir replace with new components from OEM as part of valve enhancement.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
: 12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.
2 of 2
2 of 2 Form NR-1 Attachment


FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                                         Pg. 1 of 2
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
: 1. Manufactured and certified by                 Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder]
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder]
: 2. Manufactured         for   Pennsylvania Power & Light                       Berwick, PA             18603
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603
                                                                                        -name and address ot Iurc aserl
-name and address ot Iurc aserl
: 3. Location of installation           Susquehanna I 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location of installation Susquehanna I 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
    *...                                r   Ds      4         *A 4nlK C*         II               R1 ,60600 PSI                                   N/A                           2001 ier

: 4. Type.              .3LlUtU         L       exv.                                                               PSI.'--.---~'r~.

spec.                           tmhl                                    j (yer ud (drawing no.)                       (Mari. &Pee,no                                                                    *....
r Ds
                                                                                                "S7t1                                                                    N/A 1
4
: 5. ASME Code, Section III, Division 1:                           197                            S71 (editon)                 islolsnoi    -~gj                        (class)
*A 4nlK C*
Date                  N/A
II R1 600 PSI N/A 2001
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)                           N/A             Revision                   N/A
.3LlUtU L
: 7. Remarks:           Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA ASME (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of Section III 1971 Edition summer 1971 addenda 5.312          Min. design thickness (in.)          5.094          Dia. ID (ft & in.)              N/A        Length overall (ft& In.)            N/A
exv.  
,60 PSI.'--.---~'r~.
ier tmhl spec.
(yer ud (drawing no.)
: 5. ASME Code, Section III, Division 1:
(Mari. &Pee, no (editon)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
"S7t1 1
N/A 197 S71 N/A Revision N/A Date N/A
: 7. Remarks:
Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
: 8. Nom. Thickness (In.)
: 8. Nom. Thickness (In.)
of this report
5.312 Min. design thickness (in.)
: 9. When applicable, Certificate Holders' Data Reports are attached for each item National                                  Part or Appurtenance                                        National Part or Appurtenance                                                                         Serial Number                                       Board No.
5.094 Dia. ID (ft & in.)
Serial Number                            Board No.                                                                                      In Numerical Order In Numerical Order (1)    HT: H3391 S/N 1                              N/A                               (26)                                          I (27)
N/A Length overall (ft& In.)
      - (2)              H3391 S/N HT: H3391       S/N 23                      N/A N/A                                                                              I
N/A
: 9. When applicable, Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number HT: H3391 S/N 1 National Board No.
In Numerical Order N/A HT: H3391 S/N 2 N/A HT: H3391 S/N 3 N/A 4-4.
.3.
+
Part or Appurtenance Serial Number (26)
(27)
_(28)
_(28)
(3)                                                                                                                                   4 (29) ______________________________________________________
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(38)
I I
4 National Board No.
In Numerical Order I
_________________________ 4-
_________________________ 4.
_________________________ 4.
_________________________ +
_________________________ +
_________________________ 4
-4 4.
.4.
L (39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
I I
4
: 0. Design pressure 1250 psi.
Temp.
575 "F. Hydro. test pressure
*Supplemental Information In the form of lists. sketches, or drawings may be used provided (1 ) size Is 8 % xI 1. (2) Information In Items 2 and 3 on this Date Report Is Included on each sheet is numbered and the number of sheets is recorded at the top of this form.
This form JE00040) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.
: 4. Type.
Pg. 1 of 2 (1)
- (2)
(3)
(4)
(4)
(5)
(5)
(6)
(6)
(7)
(7)
(30)
(8)
(31)
(9)
(32)
(10)
(33)
(11)
I
_________________________              4-(8)                                                                                           _________________________              4.
(9)                                                                                    (34)
_________________________              4.
(10) 4-                                                  (35)
_________________________              +
: 4.                                                  (36)
(11)                                                                                           _________________________              +
(12)
(12)
                                              .3.
(14)
(37)  _________________________              4
(15)
                                              +                                                  (38)
(16)
                          -.                -4                                                                                                              ---
(14)                                                                                    (39)
: 4.                                                  (40)
(15)                                                                                                                                  I
                                              .4.                                                (41)
(16)                                                                                                                                    I (42)
(17)
(17)
(18)                                                                                    (43)
(18)
(19)                                                                                     (44)                                          4 (20)                                                                                    (45)
(19)
(46)
(20)
(21)
(21)
(22)                                                                                    (47)
(22)
(48)
(23)
(23)
(49)
(24)
(24)
(50)
(25)
(25)
L L(50)
N/A
                                                                                                    "F. Hydro. test pressure                              N/A             At temp. *F
(*oen applcable)
: 0. Design pressure                  1250            psi. Temp.            575                                                            (*oen applcable)
At temp. *F L(50) j (class) islolsnoi
(2) Information In Items 2 and 3 on this Date Report Is
-~gj
  *Supplemental Information In the form of lists. sketches, or drawings may be used provided (1) size Is 8 %xI1.
{1218e)
Included on each sheet is numbered and the number of sheets is recorded at the top of this form.
Reprint (7191)
NJ 07007-2300.
{1218e)                               This form JE00040) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield,                                      Reprint (7191)


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.         HT: H3391 S/N 1                 through         SIN 3 CERTIFICATION OF DESIGN P.E. State          N/A              Reg. no.                          N/A Design specifications certified by                               N/A (when applficabe)
Certificate Holders' Serial Nos.
P.E. State           N/A             Reg. no.                           N/A N/A Design report
HT: H3391 S/N 1 through SIN 3 CERTIFICATION OF DESIGN Design specifications certified by Design report
* certified by (when applicable)
* certified by N/A (when applficabe)
CERTIFICATE OF COMI this (these)
N/A (when applicable)
Cover We certify that the statements made in this report are correct and that rules of construction of the ASME     Code, Section   III, Division 1.
P.E. State N/A P.E. State N/A Reg. no.
conforms to the N2607                            Expires                                    6-1 3-04              _0 NPT Certificate of Authorization No.
N/A Reg. no.
Signed Date                                       Name             Atwood & Morrill Co., Inc.
N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
(NPT Cordficite Ho4der)                               IV                (outgo-Azed representatiYO)
NPT Certificate of Authorization No.
CERTIFICATE OF INSPECTION Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission issued by the National Board of Boiler and tt
Date N2607 Expires Name Atwood & Morrill Co., Inc.
* I* t 0  I  dP"*A New York                       And employed by                                                       i-.fl.11.1 at I. ,U.
(NPT Cordficite Ho4der) 6-1 3-04
                                                                                                                                  /W21'/0                      and state that to the of                 Hartford, CT                     have inspected these items described in this Data Report on or appurtenances in accordance with the           ASME      Code, Section Best of my knowledge and belief,       the Certificate Holder has fabricated these parts               above.
_0 Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by i-.fl.11.1 at I.,U.
  "* Divisibn 1. Each part listed has been authorized         for stamping     on the date shown expressed or Implied, concerning the equipment described signing this certificate, neither the inspector nor his employer makes any warranty, Furthermore,   neither the inspector   nor   his employer     shall be liable in any manner for any personal Injury or property damage or
of Hartford, CT have inspected these items described in this Data Report on  
.,i this Data  Report.
/W21'/0 and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section
loss of any kind arising from or connected         with this Inspection
"* Divisibn 1. Each part listed has been authorized for stamping on the date shown above.
                                                      .                                                        Commissions        .,                            .
signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described
Date                               Signed                                                                                                                             staw or prov. and no]
.,i this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection Date Signed Commissions (authonzea Kwpec~tor (Nal 8d. (ind. Endomwments) an staw or prov. and no]
(authonzea Kwpec~tor                                         (Nal 8d. (ind. Endomwments) an
Cover IV (outgo-Azed representatiYO) tt I*
t 0 I
dP"*A


FOR IDENTICAL FORM N-2 CERTIFICATE HOLDERS' DATA REPORT NUCLEAR             PARTS           AND         APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
III As Required by the Provisions of the ASME Code, Section                                                                             Pg. 1 of 2 Not to Exceed One Day's Production
As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2
: 1. Manufactured and certified by                 Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
Pennsylvania Power & Light - Berwick, PA                                           18603
: 2. Manufactured for Pennsylvania Power & Light - Berwick, PA 18603 (name and address of Purchaser)
: 2. Manufactured for                                                                          (name     and address of Purchaser)
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 3. Location     of installation         Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
: 4. Type:  
SA 479-304                                85,700 PSI                                N/A                        2001
"32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)
: 4. Type:             "32462-613-C Rev.0                                                                                                                 (CRl)                     (yea bjiql (marl. spec. no.)                       (tensile strength)
(marl. spec. no.)
(drawing no.)
(tensile strength)
1971                                  S71                                  1                            N/A
(CRl)
: 5. ASME Code, Section III, Division 1:                           .
(yea bjiql
(class)                     (Code Case no.)
: 5. ASME Code, Section III, Division 1:  
(edition)                    (addenda date)
. 1971 S71 1
N/A'                Revision                N/A          Date                  N/A
N/A (edition)
(addenda date)
(class)
(Code Case no.)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
: 6. Fabricated in accordance with Const. Spec. (Div. 2 only)
(no.)
N/A' Revision N/A Date N/A (no.)
QLA
: 7. Remarks:
: 7. Remarks:         Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 the    required    information        of ASME This certification meets (LA&M S.O. 90168) *Dwg. prepared by A&M.
Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (LA&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda
Section III 1971 Edition Summer 1971 addenda 1.36             Dia. ID (ft & in.)             N/A . Length overall (ft& In.)             N/A
: 8. Nom. Thickness (in.)
: 8. Nom. Thickness        (in.)      1.50        Min. design thickness (in.)
1.50 Min. design thickness (in.)
are attached for each Item of this report:
1.36 Dia. ID (ft & in.)
: 9. When applicable, Certificate Holders' Data Reports Part or Appurtenance                                National National                                                                                              Board No.
N/A  
Part or Appurtenance                                                                                    Serial Number Board No.                                                                                        In Numerical Order Serial Number                        In Numerical Order (26).
. Length overall (ft& In.)
1                    N/A (1)    HT:    54682 S/N                                                                        (27) 2                      N/A (2)     HT:    54682 S/N                                                                        .(28) 3                      N/A (3)     HT:  54682 S/N                                                                        (29) 4                      N/A (4)     HT:  54682 S/N                                                                        (30) 5                    N/A (5)     HT:  54682 S/N                                                                        (31) 6                    N/A (6)     HT:  54682 S/N                                                                        (32) 8                    N/A (7). HT:  54682 S/N                                                                          (33) 9                    N/A (8)      HT:  54682 S/N                                                                          (34)
N/A
(1)                                                                                              (35)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:
(1)
(2)
(3)
(4)
(5)
(6)
(7).
(8)
(1)
(10)
(10)
(11)
(12)
Part or Appurtenance Serial Number HT: 54682 S/N 1 HT: 54682 S/N 2 HT: 54682 S/N 3 HT: 54682 S/N 4 HT: 54682 S/N 5 HT: 54682 S/N 6 HT: 54682 S/N 8 HT: 54682 S/N 9 (14)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
: 10. Design pressure National Board No.
In Numerical Order N/A N/A N/A N/A N/A N/A N/A N/A 1250 psi.
Temp.
Part or Appurtenance National Serial Number Board No.
In Numerical Order (26).
(27)
.(28)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(36)
(11)
(37)
(37)
(12)
(.38)
(.38)
(39)
(39)
(14)                                                                                              (40)
(40)
(41)
(41)
(16)
(42)
(42)
(17)                                                                                              (43)
(43)
(18)                                                                                              (44)
(44)
(19)
(45)
(45)
(20)                                                                                              (46)
(46)
(21)                                                                                              (47)
(47)
(22)
(48)
(48)
(23)
(49)  
(49)
* (50)  
(24)
*e J..J....  
(25)                                                                                              *(50)
.ree inKIIA At temp. '17ryuu ct J
                                                                                                                          *e   ct*
e~,
J..J.... J e~,
w
                                                                                                                                      .ree     inKIIA           w              At temp.   '17ryuu
*Supplemental Information In the form of lists. sketches, or drawings may be used provided (1) size Is a 'A x I 1, (2) Information In Items 2 and 3 on this Data Report 15 Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.
: 10. Design pressure                  1250            psi. Temp.                                  575. nyro.              p .(when                applicable)}
(12188)
Data Report 15 be used provided (1) size Is a 'A x I 1, (2) Information In Items 2 and 3 on this
This form (E00040) may be obtained from the.Order Dept. ASME. 22 Law Drive, Box 2300, Fairfield, NJ. 07007-2300.
    *Supplemental Information In the form of lists. sketches, or drawings may numbered   and the number of sheets   Is recorded   at the top   of this form.
ReprInt (71 911 575.
Included on each sheet Is ASME. 22 Law Drive, Box 2300, Fairfield, NJ.07007-2300.
nyro.
(12188)                                This form (E00040) may be obtained from the.Order Dept.
p.(when applicable)}
ReprInt (71911


FORM N-2 (Back - Pg. 2 of 2)
FORM N-2 (Back - Pg. 2 of 2)
Certificate Holders' Serial Nos.         HT: 54682 S/N 1               through         S/N 6, 8 & 9 CERTIFICATION OF DESIGN P.E. State        N/A            Reg. no.                          N/A Design specifications certified by                             N/A
Certificate Holders' Serial Nos.
HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A
(,he.n appficaWI.)
(,he.n appficaWI.)
N/A                               P.E. State         N/A             Reg. no.                           N/A Design report      certified by (when applicable)
N/A (when applicable)
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)                                           Pilot Poppet conforms to the rules of construction of the ASME Code, Section III, Division 1.
P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section III, Division 1.
NPT Certificate of Authorization No.                           N2607                         Expires                                 6-13-04~
NPT Certificate of Authorization No.
Name            Atwood & Morrill Co., Inc.                     Signed          701 Date                                                                                                                m  m                                  ,*
N2607 Expires Pilot Poppet 6-13-04~
(au*,otiz ed representative (NFT CatblIcate Hoid.E 6-13-04 CERTIFICATE OF INSPECTION Pressure Vessel Inspectors and the State or Province of I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Nw    Ynrk                  And employed by                                                   HSB.I & I. Co.
Atwood & Morrill Co., Inc.
HSBI&I Co.
(NFT CatblIcate Hoid.E Signed 701 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by HSB.I & I. Co.
of               Hartford, CT                   have Inspected these Items described in this Data Report on                     ,                      and state that to the and belief, the Certificate Holder   has   fabricated   these parts or appurtenances   In accordgfncefwith the ASME Code, Section st of my knowledge Division 1. Each part listed has been authorized for stamping on the date shown above.
of Hartford, CT have Inspected these Items described in this Data Report on and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordgfncefwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.
or implied, concerning the equipment described By signing this certificate, neither the inspector nor his employer makes any warranty, expressed in any manner for any personal Injury or property damage or in this Data Report. Furthermore, neither the inspector nor his employer shall be liable loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.
Signed Commissions           tJlX-$ P7 e ,0',A 1 Date                                                                                                                     l~fl             Enosmen
Commissions tJlX -$ P7 e,0',A 1 Date l~fl  
                                                                                                                                              -ed             ndaae , v an n.1
-ed Enosmen ndaae v
an n.1 Reg. no.
Reg. no.
N/A N/A Date Name Nw Ynrk 6-13-04 m
m HSBI&I Co.
(au*,otiz ed representative Signed
([Narl 8d. find. EndorserenWs) IMd sut of pray. and no.]
([Narl 8d. find. EndorserenWs) IMd sut of pray. and no.]


Assigned to: ????                                                              FOR INFORMATION ONLY                                                                         Expires On:\?
FOR INFORMATION ONLY FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*
As Required.by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production
As Required.by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production                                                       Pg. 1 of 2
: 1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (nane and &ddomeu of NPT CetSicate Molder)
: 1. Manufactured and certified by           Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (nane and &ddomeu of NPT CetSicate Molder)
: 2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and adress of PurthlINd
: 2. Manufactured for         Pennsylvania Power & Light                     Berwick, PA 18603 (name and adress of PurthlINd
: 3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and adrhss)
: 3. Location of installation       Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and adrhss)
: 4. Type:
: 4. Type:             32467-622-D Rev.7                   SA 105 GRII                      77.100 PSI                        N/A                        2001 (dra i nion1) i                        (marl spec. no.)                i$7a1 strong"
32467-622-D Rev.7 (dra i i nion1)  
        .5. ASME Code. Section III, Division 1:                     1971                         S71                       I                              N/A (odmoid                  IIOeO3 daia)                                              (cod. case no.)
.5. ASME Code. Section III, Division 1:
: 6. Fabricated In accordance with Const. Spec. (Div. 2 only)                     N/A           Revision         N/A           Date                 N/A (Re) 7, Remarks=:         Cust.Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000_OLA (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
SA 105 GRII (marl spec. no.)
: 8. Nom. Thickness (in.)       7.500       Min. design thickness (in.)         5.49         Dia. ID (ft IIn.) N/A         Length overall (ft& In.)       N/A
1971 (odmoid 77.100 PSI i$7a1 strong" S71 N/A I
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance                       National                                Part or Appurtenance
IIOeO3 daia)
                                                                                                          . Serial                                 National Serial Number                          Board No.                                          Number                        Board No.
: 6. Fabricated In accordance with Const. Spec. (Div. 2 only)
in Numerical Order                                                               In Numerical Order (1)
N/A Revision N/A Date (Re) 7, Remarks=:
HT: 245951 S/N 6                          N/A                           (26)
Cust.Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000_OLA 2001 N/A (cod. case no.)
(2)                                                                            (27)
N/A (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda
(3)                                                                            (2a)
: 8. Nom. Thickness (in.)
(4)                                                                            (29)
7.500 Min. design thickness (in.)
(5)                                                                            (30)
5.49 Dia. ID (ft I In.)
(a)                                                                            (31)
N/A Length overall (ft& In.)
(7)                                                                            (3M)
N/A
(a)                                                                            (33)
: 9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance Serial Number HT: 245951 S/N 6 National Board No.
(9)                                                                            (34)
in Numerical Order N/A 1.
(10)
Part or Appurtenance
.Serial Number (26)
(27)
(2a)
(29)
(30)
(31)
(3M)
(33)
(34)
(35)
(35)
(11)
(36)  
(36)
;P7)
(12)                                                                            ;P7)
(38)
(13)                                                                            (38)
(39)
(14)                                                                            (39)
(40)
(40)
(15)                                                                            (41)
(41)
(17)                                                                            (42)
(42)
(18)                                                                            (43)
(43)
(44)
(44)
(20)                                                                            (45)
(45)
(21)                                                                            (46)
(46)
(22)                                                                            (47)
(47)
(23)                                                                            (48)
(48)
(24)                                                                            (49)
(49)
              .j2)                                                                              (50) 1.
(50)
: 10. Design pressure             1250           psL Temp.                 575       "*F.Hydro. test pressure                 N/A              At temp. "F (When spoicabse)  .
National Board No.
          "Supplemental ldnfmtaloIn ithe form ot l*at, as hes, or drawings may be used provided I ) sins I % x 11. (2) ndormtiaon In hems 2and 3 on this Oaft Report is included 00 each shoe is lumbered and Ot number of shoet is recorded at te top of 0la form.
In Numerical Order
(12mS5)                           This form (E00040) may be obtaind from ite   Order Dept.. ASME 2 Law Ora. Box 20, Fablld. NJ 07007-2300.
: 10. Design pressure 1250 psL Temp.
575
"*F.
Hydro. test pressure "Supplemental ldnfmtaloIn ithe form ot l*at, as hes, or drawings may be used provided I ) sin s I % x 11. (2) ndormtiaon In hems 2 and 3 on this Oaft Report is included 00 each shoe is lumbered and Ot number of shoet is recorded at te top of 0la form.
(12mS5)
This form (E00040) may be obtaind from ite Order Dept.. ASME 2 Law Ora. Box 20, Fablld. NJ 07007-2300.
Pg. 1 of 2 (1)
(2)
(3)
(4)
(5)
(a)
(7)
(a)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(17)
(18)
(20)
(21)
(22)
(23)
(24)
.j2)
N/A (When spoicabse).
At temp. "F Expires On:\\?
Assigned to: ????


Assigned to: t???e                                                        FOR INFORMATION ONLY                                                                     Expires On: \??
FOR INFORMATION ONLY Reprint 71 Iti)
Reprint 71 Iti)
FORM N-2 (Back - Pg.2 of 2)
FORM N-2 (Back - Pg.2 of 2)
Certificate Holders' Serial Nos. HT: 245951 S/N 6         through       N/A CERTIFICATION OF DESIGN Design specifications certified by         N/A                                     P.E.     N/A             Reg. no.             N/A State Design report certifed by                 N/A                                       P.E.     N/A             Reg. no.             N/A State
Certificate Holders' Serial Nos.
* 0*- ,pph-bt)
HT: 245951 S/N 6 through N/A CERTIFICATION OF DESIGN Design specifications certified by N/A P.E.
CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)                               Poppet' conforms to the rules of con.truction of the ASME Code, Secdon III, Division 1.
N/A Reg. no.
NPT Certificate of Authorization No.                       N2607                     Expires.                       6-13-04 Date         /49     91                 Name           Atwood & Morrill Co., Inc.               Signed (NMr Ce.afit   Htddw)                                   (Uftwized rip,,eanwW3 CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York                     And employed by                                         H.S.B.I & I. Co.
N/A State Design report certifed by N/A P.E.
of               Hartford, CT                 have inspected these items described in this Data Report on   4; /-Z     '/       , and state that.to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Ill. Division 1. Each part listed has been authorized for stamping on the date shown above.
N/A Reg. no.
N/A State
* 0*-,pph-bt)
CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)
Poppet' conforms to the rules of con.truction of the ASME Code, Secdon III, Division 1.
NPT Certificate of Authorization No.
N2607 Expires.
6-13-04 Date  
/49 91 Name Atwood & Morrill Co., Inc.
Signed (NMr Ce.afit Htddw)
(Uftwized rip,,eanwW3 CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.
of Hartford, CT have inspected these items described in this Data Report on 4; /-Z  
' /  
, and state that.to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Ill. Division 1. Each part listed has been authorized for stamping on the date shown above.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the Inspector nor his employer shall be Hable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the Inspector nor his employer shall be Hable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.
Date Z2                         Signed
Date Z2 Signed Commissions
* Commissions    >v*,   d)7       ..X   A4J"
>v*,
                                                                    /   aUVW-
d)7  
                                                                        ./(     -S   -,                            an ad. POAL E.ndorawfruA a WA SUW       or . and n7.j i"
.. X A4J"  
r.t
/  
./(
aUVW-
-S an ad.
POAL E.ndorawfruA a WA SUW or i"
. and n7.j r.t Expires On: \\??
Assigned to: t???e


APPENDIX D.3 SNUBBER REPLACEMENT NIS-2 FORMS
APPENDIX D.3 SNUBBER REPLACEMENT NIS-2 FORMS
Line 2,582: Line 5,050:


==SUMMARY==
==SUMMARY==
 
==1.0 INTRODUCTION==
==1.0     INTRODUCTION==
 
This summary identifies the work performed on ASME Section XI Snubbers (Classes 1, 2 or 3 Safety Related Snubbers, parts for replacements and repairs for which ISI has NIS-2 responsibility). This work was performed during the Unit 1 - 12th Refueling and Inspection Outage.
This summary identifies the work performed on ASME Section XI Snubbers (Classes 1, 2 or 3 Safety Related Snubbers, parts for replacements and repairs for which ISI has NIS-2 responsibility). This work was performed during the Unit 1 - 12th Refueling and Inspection Outage.
2.0     CODE COMPLIANCE  
2.0 CODE COMPLIANCE  


==SUMMARY==
==SUMMARY==
All work on ASME Section XI items meet the requirements of IWA-7000 (Replacement) and IWA-4000 (Repair) of ASME Section XI 1989 Edition, no Addenda.
All work on ASME Section XI items meet the requirements of IWA-7000 (Replacement) and IWA-4000 (Repair) of ASME Section XI 1989 Edition, no Addenda.
3.0     REPLACEMENT AND REPAIR  
3.0 REPLACEMENT AND REPAIR  


==SUMMARY==
==SUMMARY==
Work in this area consists of Work Orders for Section XI replacements of snubbers, parts and ASME Section XI Repair.
Work in this area consists of Work Orders for Section XI replacements of snubbers, parts and ASME Section XI Repair.
3.A       Summary of replacements for snubbers, by system, Work Order Number     and Support Number (see Attachment 3.A).
3.A Summary of replacements for snubbers, by system, Work Order Number and Support Number (see Attachment 3.A).
3.B       Summary of replacement of snubber parts by system, Work Order Number, Support Number, and Replaced Parts (See Attachment 3.B).
3.B Summary of replacement of snubber parts by system, Work Order Number, Support Number, and Replaced Parts (See Attachment 3.B).
3.C       Summary of repair tack weld shim by System, Work Order Number, Support Number by System, and Repair (see Attachment 3.C).
3.C Summary of repair tack weld shim by System, Work Order Number, Support Number by System, and Repair (see Attachment 3.C).
H:\snubbers\snubrepr.doc
H:\\snubbers\\snubrepr.doc
 
.A SNUBBERS REPLACED H:\\snubbers\\snubrepr.doc N-5 SUS.
Attachment 3.A SNUBBERS REPLACED N-5 SUS.       WORK ORDER           SUPPORT IDENTIFICATION         I 183A-II         311260           DBB101H5B 183E-111       299126         SPHCC131H2019 183E-III       299126         SPHCC138H2009 I                 I I                 i H:\snubbers\snubrepr.doc
WORK ORDER SUPPORT IDENTIFICATION I
183A-II 311260 DBB101H5B 183E-111 299126 SPHCC131H2019 183E-III 299126 SPHCC138H2009 I
I I
i


ATTACHMENT 3.B REPLACEMENT OF SNUBBER PARTS N-5 SUS.             WORK ORDER       SUPPORT             REPLACED PARTS IDENTIFICATION 161 B-I             311258         DBA101H8     1 Load Stud, 2 Heavy Hex Nuts 4                 4
ATTACHMENT 3.B REPLACEMENT OF SNUBBER PARTS H:\\snubbers\\snubrepr.doc N-5 SUS.
&#xfd; i                I                I H:\snubbers\snubrepr.doc
WORK ORDER SUPPORT REPLACED PARTS IDENTIFICATION 161 B-I 311258 DBA101H8 1 Load Stud, 2 Heavy Hex Nuts 4
4 i
I I
&#xfd;


ATTACHMENT 3.C REPAIR OF SUPPORT PART N-5 SUS.             WORK ORDER       SUPPORT             REPAIR PART IDENTIFICATION                         *__
ATTACHMENT 3.C REPAIR OF SUPPORT PART H:\\snubbers\\snubrepr.doc N-5 SUS.
149A-II             390868         GBB104H8     Large Bore Pipe Support (SHIM)
WORK ORDER SUPPORT REPAIR PART IDENTIFICATION 149A-II 390868 GBB104H8 Large Bore Pipe Support (SHIM)
T               r               1 4-
T r
                                                    +
1 4-
I               h H:\snubbers\snubrepr.doc
+
I h


149A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
149A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                       PPL Susquehanna, LLC                                     Date                              5/03/02 Name Two North Ninth St., Allentown, PA 18101                                 Sheet            1            of Address
: 1. Owner
: 2. Plant                Susquehanna Steam Electric Station                               Unit                                 One Name Maint PCWO               Code Form No.
: 2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
769 Salem Blvd, Berwick, PA 18603                                        390868                     102149004 Address                                                            Repair Organization P.O. No.. Job No.. etc.
: 3. Work Performed by PPL Susc Two North Ninth St., Allentc Address
: 3. Work Performed by                  PPL Suscquehanna, LLC                             Type Code Symbol Stamp                           None Name Two North Ninth St., Allentc)wn,         PA 18101                       Authorization No.                             N/A Address Expiration Date                             N/A
: 4. Identification of System Date Sheet Unit 5/03/02 1
: 4. Identification of System                        149A, Class II, RHR System - Pool Spray, Pumps and Auxiliary
of One Maint PCWO Code Form No.
: 5. (a) Applicable Construction Code                 III         19   71     Edition,     thru W72           Addenda,         N/A               Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19       89 No Add.
390868 102149004 Repair Organization P.O. No.. Job No.. etc.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                Repaired,              Code Manufacturer        Board                Other            Year          Replaced, or          Stamped Name of                  Name of Component              Manufacturer          Serial No.          No.            Identification          Built        Replacement              No)or (Yes Large Pipe Support            Bechtel                N/A              N/A            GBB104H8              1982            Repaired                No (SHIM)
quehanna, LLC Type Code Symbol Stamp None Name  
I                      &                  4              4                      4              1                        +
)wn, PA 18101 Authorization No.
4                                          4                                                    1 4                                        I                                      t            t                        t
N/A Expiration Date N/A 149A, Class II, RHR System - Pool Spray, Pumps and Auxiliary
: 7. Description of Work                                               Repaired by tack welding of SHIM.
: 5. (a) Applicable Construction Code III 19 71
: 8. Tests Conducted:       Hydrostatic     F       Pneumatic     r-       Nominal Operating Pressure             E                     None X Other     F       Pressure                     psi     Test Temp.                           &deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: Edition, thru W72
(12/82)                        This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 No Add.
: 6. Identification of Components Repaired or Replaced and Replacement Components
: 7. Description of Work Repaired by tack welding of SHIM.
: 8. Tests Conducted:
Hydrostatic F Pneumatic r-Nominal Operating Pressure E
None X Other F
Pressure psi Test Temp.  
&deg;F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 ASME National
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Large Pipe Support Bechtel N/A N/A GBB104H8 1982 Repaired No (SHIM)
I 4
4 4
1
+
4 4
1 4
I t
t t
(12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks       N/A Aoolicable Manufacturer's Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                       Repair         conforms to the rules of the ASME Code, Section XI.                                                                         repair or replacement Type Code Symbol Stamp                                                                       N/A Certificate of Authorization No.                   N/A                       Expiration                                 N/A f-                                               Date Signed                                   4                                       Date                                       20     02
: 9. Remarks N/A Aoolicable Manufacturer's Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code, Section XI.
                                        ,Tte     Spv     ieMdfiain           ru Kaer or 0YIser's CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by               FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON. RHODE ISLAND                                                                         have inspected the components described in this Owner's Report during the period           03/01/02                               to       04/01/02                     , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A f-Date Signed 4
Date 20 02 Kaer or 0YIser's
,Tte Spv ieMdfiain ru CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(L,}/aj                   (7"*       aureCommissions                                     NB7980 I PA 2204 Inspector's                                                           National Board, State, Province, and Endorsements Date MA&?     LO                     2002
(L,}/aj (7"*
                                                                                                                                                      )
aureCommissions NB7980 I PA 2204 Inspector's National Board, State, Province, and Endorsements Date MA&? LO 2002
)


161 B-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
161 B-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner                         PPL Susquehanna, LLC                                       Date                              5/03102 Name Two North Ninth St., Allentown, PA 18101                                   Sheet            1          of Address
: 1. Owner
: 2. Plant                  Susquehanna Steam Electric Station                                 Unit                                ONE Name MAIN/PCWO                    Code Form No.
: 2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
769 Salem Blvd, Berwick, PA 18603                                         311258                         I 02 161 005 Address                                                            Repair Organization P.O. No., Job No., etc.
: 3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit MAIN/PCWO 311258 5/03102 1
: 3. Work Performed by                    PPL Susquehanna, LLC                                Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                                    Authorization No.                             N/A Address Expiration Expiration Date                             N/A
of ONE Code Form No.
: 4. Identification of System                                           161 B, Class I, Reactor Water Clean-Up
I 02 161 005 Repair Organization P.O. No., Job No., etc.
: 5. (a) Applicable Construction Code                     III         19   71     Edition,     thru W'72       Addenda,         N/A               Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19           89 NO ADD.
Type Code Symbol Stamp None Authorization No.
: 6. Identification of Components Repaired or Replaced and Replacement Components r                    rI ASME National                                                Repaired,            Code Name of                 Name of               Manufacturer       Board                                                Replaced, or        Stamped Other              Year Component              Manufacturer             Serial No.         No.                                               Replacement           (Yes or Identification        Built No) 1 Load Stud               GRINNEL               Item #13*(1)         N/A           DBA101H8               (1)             Replaced             NO 1 Load Stud               GRINNEL               Item #13"(1)         N/A           DBA101H8               (1)         Replacement             NO 2 Heavy Hex Nuts             GRINNEL               Item #14*(1)         N/A           DBA101H8             *(1)             Replaced             NO 2 Heavy Hex Nuts             GRINNEL               Item #14"(1)         N/A           DBA101H8             *(1)         Replacement             NO I10 I r-t 1Iz: Srnar/-leat iNuiber arln T ear Built Not AvailaDle.
N/A Expiration Date N/A
: 7. Description of Work                                   Replaced existing parts with sufficient replacement parts.
: 4. Identification of System 161 B, Class I, Reactor Water Clean-Up
: 8. Tests Conducted:         Hydrostatic     []         Pneumatic     El       Nominal Operating Pressure           r-1                   None X Other R           Pressure                       psi     Test Temp.                         "F S       NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: 5. (a) Applicable Construction Code III 19 71
(12/82)                          This form (EO0030) may be obtained from the Order Dept, ASME, 345 E. 47th SL, New York, N. Y. 10017
: Edition, thru W'72
: Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADD.
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component r
r I
Name of Manufacturer Manufacturer Serial No.
National Board No.
Other Identification Year Built
: Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No) 1 Load Stud GRINNEL Item #13*(1)
N/A DBA101H8 (1)
Replaced NO 1 Load Stud GRINNEL Item #13"(1)
N/A DBA101H8 (1)
Replacement NO 2 Heavy Hex Nuts GRINNEL Item #14*(1)
N/A DBA101H8  
*(1)
Replaced NO 2 Heavy Hex Nuts GRINNEL Item #14"(1)
N/A DBA101H8  
*(1)
Replacement NO I10 I r-t 1Iz: Srnar/-leat iNuiber arln T ear Built Not AvailaDle.
: 7. Description of Work Replaced existing parts with sufficient replacement parts.
: 8. Tests Conducted:
Hydrostatic []
Pneumatic El Nominal Operating Pressure r-1 None X Other R
Pressure psi Test Temp.  
"F S
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (EO0030) may be obtained from the Order Dept, ASME, 345 E. 47th SL, New York, N. Y. 10017 Expiration Date (12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         N/A Applicable Manufacturers Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                   Replacement         conforms to the rules of the ASME Code, Section XI.                                                                         repair or rep4acerneni Type Code Symbol Stamp                                                                       N/A Certificate of Authorization No.                     N/A                     Expiration                                 N/A Date Signed 6             1 ,           '                                              Date                                       ,20     02 Orn er or rer&   Destindee, Ti e' S~pv. Sit. Modificatiorns Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by               FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON. RHODE ISLAND                                                                           have inspected the components described in this Owner's Report during the period             03/01/02                               to 04/01/02                             , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
: 9. Remarks N/A Applicable Manufacturers Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI.
repair or rep4acerneni Type Code Symbol Stamp N/A Certificate of Authorization No.
N/A Expiration N/A Date Signed 6 1,
Date  
,20 02 Orn er or rer&
Destindee, Ti e '
S~pv. Sit. Modificatiorns Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___________________________7__Commissions                                                 NB7980 I PA 2204 Inspector's Si~lgature                                               National Board, State, Province, and Endorsements Date MA',/         10                     2002
___________________________7__Commissions NB7980 I PA 2204 Inspector's Si~lgature National Board, State, Province, and Endorsements Date MA',/
                                                                                                                                                        )
10 2002
)


183A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603
: 1. Owner                        PPL Susquehanna, LLC                                   Date                            5/03/02 Name Two North Ninth St., Allentown, PA 18101                               Sheet            1          of                      I Address
: 3. Work Performed by Address PPL Susquehanna, LLC Name Unit Main/PCWO 311260 ONE Code Form No.
: 2. Plant                Susquehanna Steam Electric Station                             Unit                              ONE Name Main/PCWO                  Code Form No.
I 02183001 Repair Organization P.O. No., Job No., etc.
769 Salem Blvd, Berwick, PA 18603                                     311260                     I 02183001 Address                                                        Repair Organization P.O. No., Job No., etc.
Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101
: 3. Work Performed by                  PPL Susquehanna, LLC                            Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, PA 18101                               Authorization No.                             N/A Address Expiration Date                              N/A
: 4. Identification of System Address Authorization No.
: 4. Identification of System                                            183A, Class 11,MAIN STEAM
Expiration Date N/A N/A 183A, Class 11, MAIN STEAM
: 5. (a) Applicable Construction Code                 III         19 71     Edition,   thru W'72       Addenda,         N/A                 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19     89
: 5. (a) Applicable Construction Code III 19 71
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                               Repaired,             Code Name of                 Name of           Manufacturer       Board             Other             Year           Replaced, or         Stamped Component             Manufacturer             Serial No.       No.         Identification         Built         Replacement             (Yes or No)
: Edition, thru W'72
Mechanical Shock         Pacific Scientific         00373           N/A         DBB101H5B             None             Replaced               No Arrestor Mechanical Shock         Pacific Scientific         14413           N/A         DBB101H5B             1983         Replacement               No Arrestor
: Addenda, N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
: 7. Description of Work                     Replaced existing snubber with same size, tested replacement snubber.
: 6. Identification of Components Repaired or Replaced and Replacement Components Code Case ASME National
: 8. Tests Conducted:       Hydrostatic   0         Pneumatic     E     Nominal Operating Pressure           El.F                  None X Other   0         Pressure                   psi     Test Temp.
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
No.
(12/82)                        This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
Identification Built Replacement (Yes or No)
Mechanical Shock Pacific Scientific 00373 N/A DBB101H5B None Replaced No Arrestor Mechanical Shock Pacific Scientific 14413 N/A DBB101H5B 1983 Replacement No Arrestor
: 7. Description of Work Replaced existing snubber with same size, tested replacement snubber.
: 8. Tests Conducted:
Hydrostatic 0
Pneumatic E
Nominal Operating Pressure Other 0 Pressure psi Test Temp.
El.F None X NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant 183A-II Date 5/03/02 Sheet 1
of I
(12/82)


FORM NIS-2 (Back) 1-Th
FORM NIS-2 (Back)
: 9. Remarks         N/A Aoolicable Manufacturer's Data Recorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                   Replacement           conforms to the rules of the ASME Code, Section XI.                                                                           repair or replacement Type Code Symbol Stamp                                                                         N/A Certificate of Authorization No.                     N/A                       Expiration                                   N/A Date Sign                                                                                 Date                           /             .20     02 Own           f)"gnee. Title or Owners                  Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION
: 9. Remarks N/A Aoolicable Manufacturer's Data Recorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI.
                                                                                                                                                                -)
repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                         and employed by                 FACTORY MUTUAL INSURANCE CO.                                     of JOHNSTON, RHODE ISLAND                                                                           have inspected the components described in this Owner's Report during the period                   03/01/02                               to         04/01/02                   , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
N/A Expiration N/A Date Sign Date  
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
/  
______          '/?           __ q                               Commissions           NB7980 I PA 2204 InspectorYSignature                                                     National Board, State, Province, and Endorsements
.20 02 Own or Owners f)"gnee. Title Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
  ,Date M. y           /&               2002
of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02  
        'I                                       -
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
                                                                                                                                                                )
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.  
'/?
q Commissions NB7980 I PA 2204 InspectorYSignature National Board, State, Province, and Endorsements  
,Date M. y  
/&
2002
'I 1-Th
-)
)


183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North N inth St., Allentown, PA 18 10 1 Address Susquehanna Steam Electric Station Date Sheet Unit 5/03/02 1
: 1. Owner                        PPL Susquehanna, LLC                                   Date                              5/03/02 Name Two North N inth St., Allentown, PA 18 10 1                             Sheet            1          of Address
of ONE Name 769 Salem Blvd, Berwick, PA 18603 Address
: 2. Plant                Susquehanna Steam Electric Station                               Unit                               ONE Name MAIN/PCWO                      Code Form No.
: 3. Work Performed by PPL Susquehan Name Two North Ninth St., Allentown, P.
769 Salem Blvd, Berwick, PA 18603                                       See Sheet 2 of 2 Address                                                            Kepair Organization P.O. No., Job No., etc.
Address
: 3. Work Performed by                  PPL SusquehanIna, LLC                             Type Code Symbol Stamp                           None Name Two North Ninth St., Allentown, P.A 18101                               Authorization No.                             N/A Address Expiration Date                             N/A
: 4. Identification of System MAIN/PCWO See Sheet 2 of 2 Code Form No.
: 4. Identification of System                                183E, Class Ill, Auto Pressure Blow Down System
Kepair Organization P.O. No., Job No., etc.
: 5. (a) Applicable Construction Code                 III         19   71     Edition,     thru W72         Addenda,        N/A                Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19       89 NO ADD.
Ina, LLC Type Code Symbol Stamp None A 18101 Authorization No.
: 6. Identification of Components Repaired or Replaced and Replacement Components ASME National                                                 Repaired,             Code Name of                 Name of           Manufacturer       Board               Other             Year         Replaced, or           Stamped Component             Manufacturer           Serial No.         No.           Identification         Built         Replacement             (Yes or No)
N/A Expiration Date N/A 183E, Class Ill, Auto Pressure Blow Down System
Mechanical Shock         Pacific Scientific         27972           N/A         SPHCC131H2019           1982             Replaced               NO Arrestor Mechanical Shock         Pacific Scientific         16349           N/A           SPHCC131H2019           1980         Replacement
: 5. (a) Applicable Construction Code III 19 71
[tern                                                                                                                                                          NO Arrestor Mechanical Shock         Pacific Scientific         22868           N/A           SPHCC138H2009           1981             Replaced               NO ter              Arrestor 2        Mechanical Shock         Pacific Scientific         13130           N/A           SPHCC138H2009           1980         Replacement               NO Arrestor
: Edition, thru W72 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADD.
: 7. Description of Work                   Replaced existing snubbers with same size, tested replacement snubbers.
: 6. Identification of Components Repaired or Replaced and Replacement Components
: 8. Tests Conducted:       Hydrostatic   E         Pneumatic     0       Nominal Operating Pressure             E                     None X Other   E-       Pressure                   psi     Test Temp.                         &deg;F PNOTE:                 Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
: Addenda, N/A ASME National
(12/82)                        This form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N. Y. 10017
: Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.
No.
Identification Built Replacement (Yes or No)
Mechanical Shock Pacific Scientific 27972 N/A SPHCC131H2019 1982 Replaced NO Arrestor Mechanical Shock Pacific Scientific 16349 N/A SPHCC131H2019 1980 Replacement NO Arrestor Mechanical Shock Pacific Scientific 22868 N/A SPHCC138H2009 1981 Replaced NO Arrestor Mechanical Shock Pacific Scientific 13130 N/A SPHCC138H2009 1980 Replacement NO Arrestor
: 7. Description of Work Replaced existing snubbers with same size, tested replacement snubbers.
: 8. Tests Conducted:
Hydrostatic E Pneumatic 0
Nominal Operating Pressure E
None X Other E-Pressure psi Test Temp.  
&deg;F PNOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N. Y. 10017
: 1. Owner
: 2. Plant Code Case
[tern ter 2
(12/82)


FORM NIS-2 (Back)
FORM NIS-2 (Back)
: 9. Remarks         N/A Aoolicable Manufacturer's Data Reoors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this                   Replacement         conforms to the rules of the ASME Code, Section XI.                                                                       repair or replacement Type Code Symbol Stamp                                                                      N/A Certificate of Authorization No.                    N/A                     Expiration                                 N/A Date 11
: 9. Remarks N/A Aoolicable Manufacturer's Data Reoors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section XI.
                                        'I Le, Title Supv. - bite Mocnlncations Group Date Date        "          "                ,20
repair or replacement N/A Expiration Date
                                                                                                                                  ,20 02 02
'I  
                -                              CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA                       and employed by                 FACTORY MUTUAL INSURANCE CO.                                   of JOHNSTON. RHODE ISLAND                                                                       have inspected the components described in this Owner's Report during the period           03/01/02                               to 04/01/02                           , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
,20 02 Date Le, Title Supv. - bite Mocnlncations Group N/A N/A Type Code Symbol Stamp Certificate of Authorization No.
CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.
of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02  
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___________._______-___I_-__                                     _Commissions
___________._______-___I_-__
_                        NB7980 I PA 2204 Inspector's Soature                                               National Board, State, Province, and Endorsements Date/Iof/         /0                   2002
_Commissions NB7980 I PA 2204 Inspector's Soature National Board, State, Province, and Endorsements Date/Iof/  
                                                                                                                                                      )
/0 2002
)
Date 11
,20 02


183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd. Berwick, PA 18603
: 1. Owner                        PPL Susquehanna, LLC                                               Date                              5/03/02 Name Two North Ninth St., Allentown, PA 18101                                           Sheet             2           of                     2 Address
: 3. Work Performed by Address PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 5/03/02 2
: 2. Plant                Susquehanna Steam Electric Station                                          Unit                                ONE Name Maint/PCWO                     /CodeFormNo.
of 2
769 Salem Blvd. Berwick, PA 18603                                                                SEE BELOW Address                                                                      Repair Organization P.O. No., Job No., etc.
ONE Maint/PCWO  
: 3. Work Performed by                  PPL Susquehanna, LLC                                          Type Code Symbol                                   None Name Two North Ninth St., Allentown, PA 18101                                          Authorization No.                             N/A Address Expiration Date                             N/A
/CodeFormNo.
: 4. Identification of System                                   183E, Class III, Auto Pressure Blow Down System
SEE BELOW Repair Organization P.O. No., Job No., etc.
: 5. (a) Applicable Construction Code                 III             19     71     Edition,         thru W'72         Addenda,         NA                 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19                 89
Type Code Symbol None Authorization No.
: 6. Identification of Components Repaired or Replaced and Replacement Components S-I-I                                                1 ITEM(S)                                       WORK ORDER NO.                                         CODE REPAIR FORM NO.
N/A Expiration Date N/A
1                                                   299126                                                   1 02 183 002 2                                                   299126                                                   1 02 183 003 I.                                                           4 t                                                             I 1-                                                           4 i                                                             i.
: 4. Identification of System 183E, Class III, Auto Pressure Blow Down System
i                                                             I
: 5. (a) Applicable Construction Code III 19 71
[_________________                                  ___________________________________________________________  ___________________________________________________________
: Edition, thru W'72
: Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
: 6. Identification of Components Repaired or Replaced and Replacement Components S-I 1
ITEM(S)
WORK ORDER NO.
CODE REPAIR FORM NO.
1 299126 1 02 183 002 2
299126 1 02 183 003 I.
4 t
I 1-4 i
i.
: 1. Owner
: 2. Plant
[_________________
i I
-I


APPENDIX E EROSION/CORROSION SCOPE OF EXAMINATIONS
APPENDIX E EROSION/CORROSION SCOPE OF EXAMINATIONS


Unit One - 12th - Li-     Aon/Corrosion   Exams           3 COMPONENT ID               DESCRIPTION            X NUMBER          %Ero DBB1222-El                   4" TEE              (X502)            0%
Unit One - 12th - Li-Aon/Corrosion Exams 3
DBC1011 -El                 TEE 6"x 4"              (X695)    21.9% BZ2 DBD1 01 2-E4A/B             30x24" TEE                (X51)    25.5% BZ3 DBD1043-El                 1Oxl0 TEE              (X153)      2.3% Z3 DBD1 051 -E7A/B               TEE16x4"                (X68)      60.7% Z1 DBD1 051 -E8                 ELB/1 6"              (X54)      70.5% Z3 DLA1 021 -E3A/B             TEE/20X12              (X-1 75)    27.9% BZ4 EBC1041-E2                 ORIFICE/4"              (X499)      8.0% Zi EBD1 143-E2A/B                 TEE/4xl"              (X683)      7.4% AZ1 GBD1 01 3-E2               RED/1 0"x8"             (X790)           0%
COMPONENT ID DBB1222-El DBC1011 -El DBD1 01 2-E4A/B DBD1043-El DBD1 051 -E7A/B DBD1 051 -E8 DLA1 021 -E3A/B EBC1041-E2 EBD1 143-E2A/B GBD1 01 3-E2 GBD1021-E2 GBD1022-El GBD1031-ElA/B GBD1033-ElA/B GBD1042-El GBD1074-E2 GBD1 193-El GBD1213-E2 GBD1214-E2 GBD1261-El GBD1361-ElA/B GBD1401-El GBD1401-E2 HBD1141 -El HBD1 141 -E2 HBD1212-E4ANB HBD1681-E3 SPEAD1 148-El SPEBD1 141-El SPGBD1 3311-El SPGBD13320-El SPGBD13322-El SPGBD1 337-El SPHBD1092-El SPHBD1096-E2 SPHBD10742-El 1SCVL-E12 1 SSH7-E3 1 SSH8-E25A/B DESCRIPTION 4" TEE TEE 6"x 4" 30x24" TEE 1Oxl0 TEE TEE16x4" ELB/1 6" TEE/20X12 ORIFICE/4" TEE/4xl" RED/1 0"x8" ELB/4 ELB/4" RED/8x6 RED/8x6 ELB/3" ELB/16" ELB/20" ELB/20" ELB/20" VALVE/8" RED/1 4x1 2" ELB/3" ELB/3" ELB/3" ELB/3 TEE/48x30" ELB/4 TEE/4xl" ELB/1" ELB/1" ELB/1" ELB/.75" ELB/1" ELB/2" VALVE/2" ELB/2" ELB/1.5 ELB/5" RED/8x5 X NUMBER (X502)
GBD1021-E2                    ELB/4              (X-1 55)     63.3% Z1 GBD1022-El                    ELB/4"              (X191)      56.96% Z1 GBD1031-ElA/B                  RED/8x6                (X791)          0%
(X695)
GBD1033-ElA/B                  RED/8x6              (X795)    37.4% AZ1 GBD1042-El                    ELB/3"              (X158)      31.0% Z3 GBD1074-E2                    ELB/16"                (X57)      18.7% Z3 GBD1 193-El                  ELB/20"              (X148)        .7% Z3 GBD1213-E2                    ELB/20"                (X49)      13.2% Z1 GBD1214-E2                    ELB/20"                (X60)      2.6% Z3 GBD1261-El                  VALVE/8"              (X218)      52.3% Z1 GBD1361-ElA/B                RED/1 4x1 2"            (X797)      28% AZ3 GBD1401-El                    ELB/3"              (X295)        34% Z3 GBD1401-E2                    ELB/3"                (X32)        1% Z3 HBD1141 -El                  ELB/3"                (X304)      50.0% Z1 HBD1 141 -E2                  ELB/3                (X-34)      48.6% Z3 HBD1212-E4ANB                TEE/48x30"                (X56)    22.4% BZ2A HBD1681-E3                    ELB/4                (X816)      30.0% Z3 SPEAD1 148-El                TEE/4xl"                (X190)      4.08% Z1 ELB/1"              (X-134)      25.8% Z3 SPEBD1 141-El SPGBD1 3311-El                  ELB/1"                (X208)    32.1% Z3 SPGBD13320-El                    ELB/1"                (X211)      15.7% Z3 ELB/.75"              (X213)      2.7% Z3 SPGBD13322-El ELB/1"                (X207)      36.9% Z3 SPGBD1 337-El SPHBD1092-El                    ELB/2"                (X205)      46.6% Z3 VALVE/2"                (X201)      56.4% Z3 SPHBD1096-E2 SPHBD10742-El                  ELB/2"                  (X38)    20.5% Z3 1SCVL-E12                    ELB/1.5              (X-173)      25.5% Z1 ELB/5"                (X189)      1.2% Z3 1SSH7-E3 RED/8x5                (X188)      8.1% BZ3 1SSH8-E25A/B
(X51)
(X153)
(X68)
(X54)
(X-1 75)
(X499)
(X683)
(X790)
(X-1 55)
(X191)
(X791)
(X795)
(X158)
(X57)
(X148)
(X49)
(X60)
(X218)
(X797)
(X295)
(X32)
(X304)
(X-34)
(X56)
(X816)
(X190)
(X-134)
(X208)
(X211)
(X213)
(X207)
(X205)
(X201)
(X38)
(X-173)
(X189)
(X188)
%Ero 0%
21.9% BZ2 25.5% BZ3 2.3% Z3 60.7% Z1 70.5% Z3 27.9% BZ4 8.0% Zi 7.4% AZ1 0%
63.3% Z1 56.96% Z1 0%
37.4% AZ1 31.0% Z3 18.7% Z3  
.7% Z3 13.2% Z1 2.6% Z3 52.3% Z1 28% AZ3 34% Z3 1% Z3 50.0% Z1 48.6% Z3 22.4% BZ2A 30.0% Z3 4.08% Z1 25.8% Z3 32.1% Z3 15.7% Z3 2.7% Z3 36.9% Z3 46.6% Z3 56.4% Z3 20.5% Z3 25.5% Z1 1.2% Z3 8.1% BZ3


SUnit                   One- 12th- List c hon/Corrosion Exams           ,W 2SCVL-E24               ELB/1.5           (X370)     31.3% Z1 1E101A-ElShell           FWHTR             (X888)     33.1% Z3 1E101 A-El Nozzle         24" Pipe           (X888)   45.5% AZ1 1E102A-E1 Shell           FWHTR             (X891)     30.4% Z2 1El 02A-E1 Nozzle         24" Pipe           (X891)         0%
SUnit One-12th-List c hon/Corrosion Exams  
,W 2SCVL-E24 ELB/1.5 (X370) 31.3% Z1 1E101A-ElShell FWHTR (X888) 33.1% Z3 1E101 A-El Nozzle 24" Pipe (X888) 45.5% AZ1 1 E102A-E1 Shell FWHTR (X891) 30.4% Z2 1 El 02A-E1 Nozzle 24" Pipe (X891) 0%


APPENDIX F CONTAINMENT INSPECTIONS
APPENDIX F CONTAINMENT INSPECTIONS


I)                                                                           UNITI1- 12 I    th RIO I   IIIIII                                                                                         I    III         I I                                                                                                                                                                                  I Drywel! Head 11    1        1            1            1        1          1                  1          1                1 NDE-VT Head and Flange                                 GV     794'                   2A          1            1                            001    345549 003 Rev 1 1
I)
NDE-VT Manhole Hatch                                    GV                            2A                      1                            001    345549        003 Rev 1 t                                            I ______ L _____ I ___
I IIIIII III I
I.Personnel             Access Airlock (X-2) 3A, C,                                                                          NDE-VT External Door                                   GV     724'       1340       D.) L       1          1              1              002    345565        003 Rev 1 Internal door                                                                3A, C,                                                                         NDE-VT GV     724'     1340         D, L         1           1             1               002    345565        003 Rev 1 i
I Drywel! Head Head and Flange Manhole Hatch GV GV 794' t
NDE-VT External Bulkhead                               GV                           3C, H         1           1                              002    345565        003 Rev 1 r                                                                                         .4-       4___      1_____              r-NDE-VT r
I ______
Internal Bulkhead                               GV I-3C, L         I I*4 1
L _____
I*1    _____
I ___
1 I         F-I   0023 I _____An9  I 345565         003 Rev 1
Personnel Access Airlock (X-2)
              -  . __________________________________________ L                   __________ L           .L.................L...................I
External Door GV 724' 1340 2A 2A 3A, C, D.) L 3A, C, Internal door GV 724' 1340 D, L 1
____________ 1______________ .1
1 1
_______________ L G:\ISI\IWL\outage U1-12 sched.xis                                                              Page 1 of 34
1 1
External Bulkhead GV 3C, H 1
1 r  
.4-4 ___
1 _____
Internal Bulkhead GV 3C, L I
I r
I- *4  
*1 _____
I _____
I An9 G:\\ISI\\IWL\\outage U1-12 sched.xis I
th UNITI1-12 RIO 1
001 001 002 002 1
1 345549 345549 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1
__________________________________________ L
__________ L  
.L.................L...................I
____________ 1 ______________.1
_______________ L 002 0023 I
1 1
Page 1 of 34 I.
I I
11 1
1 1
1 1
1 1
1 1
1 1
i r-F-I I


I                                                         UNIT 1 - &#xfd;2th RIO 1I I
I I
T    ~Ivi$~ ~            i~ 9XXXNDE-VT Barrel Section               GV                         3G     1 1     1     002   345565 003 Rev 1 Equipment Hatch (X-!)
G:\\ISl\\IWL\\outage U1-12 sched.xls UNIT 1 - &#xfd;2th RIO 1I T
NDE-VT Head and Flange             GV     724'   3150     4A. 4B   1 1     1     003   345565 003 Rev 1 NDE-VT Barrel Section               GV     724'   3150     4A. 4B   1 1     1     003   345565 003 Rev 1 Examination Category: E-A, Containment Surfaces EI1O1     Containment Vessel Pressure Retainting Boundary,__
~Iv
E!i. ACcessible SUrface Areas     :;    i:
~
Drywell   - Exterior 704' -   0&deg; to
i$~
__Drywell   Exterior             GV       719'   900         30         __________________
i~ 9XXXNDE-VT Barrel Section GV 3G 1
NDE-VT X-34B                       GV       704'     19&deg;         30   1 1     1     004   345565 003 Rev 1 NDE-VT X-35A                       GV       717'     5Q0         30   1 1     1     004   345565 003 Rev 1 NDE-VT~
1 1
X-35B                       GV       717'     48&deg;         30   1 1   1     004   345565 003 Rev 1 NDE-VT X-35C                       GV     717'     460         30   1 1   1     004   345565 003 Rev 1 G:\ISl\IWL\outage U1-12 sched.xls                                      Page 2 of 34
002 345565 003 Rev 1 Equipment Hatch (X-!)
NDE-VT Head and Flange GV 724' 3150 4A. 4B 1
1 1
003 345565 003 Rev 1 NDE-VT Barrel Section GV 724' 3150 4A. 4B 1
1 1
003 345565 003 Rev 1 Examination Category: E-A, Containment Surfaces EI1O1 Containment Vessel Pressure Retainting Boundary,__
E!i.
ACcessible SUrface Areas i:
Drywell - Exterior 704' -
0&deg; to
__Drywell Exterior GV 719' 900 30 NDE-VT X-34B GV 704' 19&deg; 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-35A GV 717' 5Q0 30 1
1 1
004 345565 003 Rev 1 NDE-VT~
X-35B GV 717' 48&deg; 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-35C GV 717' 460 30 1
1 1
004 345565 003 Rev 1 Page 2 of 34


I                                                 UNIT I - U    12tth RIO                                      4,
I
                                                  ~ti~i~f1Exa Exa               Dw.             PeiodRepot #Insp Ith~   _____________ ~     ie     z,     Ck           $. 12::1                   rcedu0re m9~X NDE-VT X-35D                       GV   717'   440       30     1   1   1   004     345565 003 Rev 1 NDE-VT X-35E                       GV   717'   410       30     1   1   1   004     345565 003 Revl1 NDE-VT X-35F                       GV   717'   390       30     1   1   1   004     345565 003 Rev 1 NDE-VT X-49B                       GV   705'   44'       30     1   1   1   004     345565 003 Rev 1 NDE-VT X-83B                       GV   705'   150       30     1   1   1   004     345565 003 Rev 1 NDE-VT X-93                         GV   717'   370       30     1   1   1   004     345565 003 Rev 1 NDE-VT X-100H                       GV   711'   530       30     1   1   1   004     345565 003 Revl1 NDE-VT X-104H                       GV   711'   22&deg;       30     1   1   1   004     345565 003 Revl1 NDE-VT X-104F                       GV   711'   360       30     1   1   1   004     345565 003 Revl1 704'- 90&deg;-to Drywell Exterior             GV   719'   1800       31 NDE-VT X-11                         GV   708'   1470       31     1   1       004     345565 003 Revl1 NDE-VT X-12                         GV   710'   1760       31     1   1   1   004     345565 003 Revl1 NDE-VT X-13B                       GV   710'   1610       31     1   1   1   004     345565 003 Revl1 NDE-VT X-15                         GV   709'   1240       31     1   1   1   004     345565 003 Revl1 NDE-VT X-90D                       GV   711'   1410       31     1   1   1   004     345565 003 Revl1 G:\ISI\IWL\outage U1-12 sched.xls                               Page 3 of 34
~ti~i~f1Exa Exa Dw.
PeiodRepot #Insp Ith~  
~
ie z,
Ck 12::1 m9~X rcedu0re NDE-VT X-35D GV 717' 440 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-35E GV 717' 410 30 1
1 1
004 345565 003 Revl1 NDE-VT X-35F GV 717' 390 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-49B GV 705' 44' 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-83B GV 705' 150 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-93 GV 717' 370 30 1
1 1
004 345565 003 Rev 1 NDE-VT X-100H GV 711' 530 30 1
1 1
004 345565 003 Revl1 NDE-VT X-104H GV 711' 22&deg; 30 1
1 1
004 345565 003 Revl1 NDE-VT X-104F GV 711' 360 30 1
1 1
004 345565 003 Revl1 704'-
90&deg;-to Drywell Exterior GV 719' 1800 31 NDE-VT X-11 GV 708' 1470 31 1
1 004 345565 003 Revl1 NDE-VT X-12 GV 710' 1760 31 1
1 1
004 345565 003 Revl1 NDE-VT X-13B GV 710' 1610 31 1
1 1
004 345565 003 Revl1 NDE-VT X-15 GV 709' 1240 31 1
1 1
004 345565 003 Revl1 NDE-VT X-90D GV 711' 1410 31 1
1 1
004 345565 003 Revl1 G:\\ISI\\IWL\\outage U1-12 sched.xls U th UNIT I - 12t RIO 4,
Page 3 of 34


I)
I)
UNIT 1               RIO ND-V X-18             GV 709'   127&deg;       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-19             GV 709'   1200       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-30B           GV 705'   1320       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-33B           GV 705'   1250       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-34A           GV 705'   1540       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-48A           GV 705'   1570       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-50B           GV 705'   1420       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-51B           GV 705'   1450       31       1 1 1 004 345565 '003Revl1 NDE-VT X-52B           GV 705'   1370       31       1 1 1 004 345565 003 Rev 1 NDE-VT X-83A           GV 705'   1500       31     1 1 1 004 345565 003 Rev 1 NDE-VT X-90E           GV 711'   1370       31     1 1 1 004 345565 003 Revl1 NDE-VT X-90F           GV 711'   1330       31     1 1 1 004 345565 003 Rev 1 704'- 1800 to
UNIT 1 RIO ND-V X-18 GV 709' 127&deg; 31 1
__Drywell Exterior GV 719'   2700       32                           _____
1 1
NDE-VT X-6 (CR0 Hatch) GV 718'   216&deg;       32       1 1 1 004 345565 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls                   Page 4 of 34
004 345565 003 Rev 1 NDE-VT X-19 GV 709' 1200 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-30B GV 705' 1320 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-33B GV 705' 1250 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-34A GV 705' 1540 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-48A GV 705' 1570 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-50B GV 705' 1420 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-51B GV 705' 1450 31 1
1 1
004 345565 '003Revl1 NDE-VT X-52B GV 705' 1370 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-83A GV 705' 1500 31 1
1 1
004 345565 003 Rev 1 NDE-VT X-90E GV 711' 1370 31 1
1 1
004 345565 003 Revl1 NDE-VT X-90F GV 711' 1330 31 1
1 1
004 345565 003 Rev 1 704'-
1800 to
__Drywell Exterior GV 719' 2700 32 NDE-VT X-6 (CR0 Hatch)
GV 718' 216&deg; 32 1
1 1
004 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 4 of 34


A, UNIT 1 -       12  th   RIO I II                     I             I           T I
A, UNIT 1 - 1 2 th RIO I II I
                  -X-10                               2090                                                IJUt--V I GV    714'                32        1    1        004    345565  003 Rev 1
I T
                  -X-13A              GV               199*                                               NDE-VT 710'                 32         1     1   1   004     345565 003 Rev 1
-X-10  
                  -X-17              GV    710'      2470o                                                NDE-VT 32        1     1  1    004    345565 003 Rev 1 X-23              GV    709'      186'                                                NDE-VT 32        1    1  1    004    345565 003 Rev 1 X-24              GV    709'      1830                                                NDE-VT 32        1        1    004    345565 003 Rev 1 X-25              GV    710'      2360                                                NDE-VT 32        1        1    004    345565  003 Rev 1 X-50A              GV              2150                                                NDE-VT 705'                32        1    1  1  004    345565  003 Rev 1 X-72A              GV              2290                                                NDE-VT 704'                32        1          1  004    345565  003 Rev I X-72B              GV              2310&deg;                                              NDE-VT 704'                32        1      1      004    345565  003 Rev 1 1  1 704'    270&deg; to Drywell Exterior  GV              3600 719'                33                1  1 X-30A              GV              322'&deg;                                              NDE-VT 710'                33        1      1      004    345565  003 Rev   1 X-33A              GV              327o                                004            NDE-VT 708'                33        1          1          345565  003 Rev   1 X-49A              GV              3270                                                NDE-VT 704'                33        1          1  004    345565  003 Rev   1 X-51A              GV            L3240                                                NDE-VT 1
-X-13A
I   II 704'
-X-17 X-23 X-24 X-25 X-50A X-72A X-72B Drywell Exterior X-30A X-33A X-49A X-51A GV GV GV GV GV GV GV GV GV GV GV GV GV GV 714' 710' 710' 709' 709' 710' 705' 704' 704' 704' 719' 710' 708' 704' 704' 2090 199*
                                            .- I III -- , III  33
2470o 186' 1830 2360 2150 2290 2310&deg; 270&deg; to 3600 322'&deg; 327o 3270 L3240 32 32 32 32 32 32 32 32 32 33 33 33 33 33 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 5 of 34 1
                                                                --      I-I     I   I   I 004
1 1
                                                                                          -- . II 345565  003 Rev 1(        1 003 Rev 1
1 1
                                                                            . I 345565 G:\ISI\IWL\outage U1-12 sched.xls                          Page 5 of 34
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
004 004 004 004 004 004 004 004 004 004 004 004 004 345565 003 Rev 1 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 IJUt--V I 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev I NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 1(
I I
I I
I I --,
II I-II I
I I
I I
I.- I I I


I)
I)
Al UNIT 1 - 12         RIO I
I G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO Al NDE-VT X-52A GV 708' 3230 33 1
NDE-VT X-52A           GV 708'   3230       33       1 1 1 004 345565 003 Rev 1 ND E-VT X-90A           GV 711'   3280       33       1 1 1 004 345565 003 Revl1 NDE-VT X-90B           GV 711' 3320       33       1 1 1 004 345565 003 Revl1 NDE-VT X-90C           GV 711' 336&deg;       33       1 1 1 004 345565 003 Rev 1 NDE-VT X-100G           GV 711'   3130       33       1 1 1 004 345565 003 Revl1 NDE-VT X-104E           GV 706'   3480       33       1 1 1 004 345565 003 Rev 1 NDE-VT X-104G           GV 711'   3530       33       1 1 1 004 345565 003 Revl1 719'-   O0&deg;to Drywell Exterior GV 749'   9Q0       34 NDE-VT X-8             GV 731'     00       34       1 1 1 005 345565 003 Revl1 NDE-VT X-21             GV 731'   4Q0       34       1 1 1 005 345565 003 RevI1 NDE-VT X-22             GV 734w   430       34       1 1 1 005 345565 003 Rev 1 NDE-VT X-27B           GV 726'   610       34       1 1 1 005 345565 003 Rev 1 NDE-VT X-28B           GV 729'   610       34       1 1 1 005 345565 003 Revl1 X-29B           GV 732'   61.       34       1 1               NDE-VT 1 005 345565 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls                  Page 6 of 34
1 1
004 345565 003 Rev 1 ND E-VT X-90A GV 711' 3280 33 1
1 1
004 345565 003 Revl1 NDE-VT X-90B GV 711' 3320 33 1
1 1
004 345565 003 Revl1 NDE-VT X-90C GV 711' 336&deg; 33 1
1 1
004 345565 003 Rev 1 NDE-VT X-100G GV 711' 3130 33 1
1 1
004 345565 003 Revl1 NDE-VT X-104E GV 706' 3480 33 1
1 1
004 345565 003 Rev 1 NDE-VT X-104G GV 711' 3530 33 1
1 1
004 345565 003 Revl1 719'-
O0&deg;to Drywell Exterior GV 749' 9Q0 34 NDE-VT X-8 GV 731' 00 34 1
1 1
005 345565 003 Revl1 NDE-VT X-21 GV 731' 4Q0 34 1
1 1
005 345565 003 RevI1 NDE-VT X-22 GV 734w 430 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-27B GV 726' 610 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-28B GV 729' 610 34 1
1 1
005 345565 003 Revl1 NDE-VT X-29B GV 732'
: 61.
34 1
1 1
005 345565 003 Rev 1 Page 6 of 34


I)
I)
UNIT '-12                  RIO I               III                         I       III               -I I          I  II I                                                                                                                                    I NDE-VT X-37D                           GV 1 735'             780       34       1I    1I__    1   005l     345565 1             ----------- Fi      -  -  i     - -  4     -  I           I     I   I       I I u   I           003 Rev 1 I                                           -r      -T        -t X-38D                                                                                                            NDE-VT GV           735'       780       34              1          1 005      345565  003 Rev 1 NDE-VT X-40E                          GV           729'       770        34 Ii        I
I II I
                                                                        -F--                      1 I 1-          1 005     345565  003 i-t  Rev 1
III I
                                                                        -r        iI          i
III  
                                                                                              -r    F                    I0 i
-I X-37D GV 1 735' 780 34 1
                                                                                                                          -r        I NDE-VT X-40F                          GV          729'      730        34        1   1       1   005     345565   003 Rev 1 NDE-VT X-40G                          GV          729'      690        34        1    1        1  005      345565  003 Rev 1 NDE-VT X-40H                          GV          729'      650        34        1    1        1  005      345565  003 Rev 1 NDE-VT X-44                            GV          726'      120 F -                          i          iL                    -I- 34    I      I 1 I          005      345565  003 Rev 1 NDE-VT x-46                            GV          727'      0.        34        1                 005 t                              ____-_I_-          I                                                      345565  003 Rev 1 NDE-VT X-48B                          GV          732'      650        34        1                  005      345565  003 Rev 1 1
1 1
NDE-VT X-53                            GV          736'      390        34                      1  005      345565  003 Rev 1 1
005l 1
NDE-VT X-54 58                          GV          736'      510        34        1             1  005
i i
                                              -f-                  I          -L                                        345565  003 Rev 1
4 I
              ---                                                                                      1 005              NDE-VT X-58B                          GV          735'      650        34        1              1            345565  003 Rev 1 1
I I
005              NDE-VT X-60B                          GV          735'      610        34        1              1            345565  003 Rev 1 X-61B                      [GV              726'      650        34        1 005 345565 NDE-VT 003 Rev 1 X-62B                          GV          726'      69&deg; 7-&#xfd;34   I 1 I         I     I 005 I 345565 NDE-VT 003 Rev 1 11 G:\ISI\lWL\outage U1-12 sched.xls                                                Page 7 of 34
I I__
I I
I u
I X-38D X-40E X-40F X-40G X-40H X-44 x-46 GV GV GV GV GV GV GV 735' 729' 729' 729' 729' 726' 727' t
____-_I_-
I X-48B X-53 X-54 X-58B X-60B GV GV GV GV GV 732' 736' 736' 735' 735' 780 770 730 690 650 120
: 0.
650 390 510 650 610 X-61B
[GV 726' 650 X-62B GV 726' 69&deg; 34 34 34 34 34 34 34 34 34 34 34 34 34 34 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 005 1
005 1
1 1
1 1
1 1
005 005 005 005 005 005 005 005 005 005 005 005 G:\\ISI\\lWL\\outage U1-12 sched.xls UNIT '-12 RIO 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 I
I I
7-&#xfd; Page 7 of 34
-t
-T
-r I
----------- F F
-r I
-r I
I i
i-tI I0 i
-F--
i i
I -
-r I
I I
-I-i iL F
58
-L I -f-11 I
I I
I I


41                                         UNIT 1-12t RIO t  . .m um Repo.t.
41
NDE-VT X-63B                   GV 726'   730         34     1 1 1   005   345565 003 Rev 1 X-64B                                                                       NDE-VT GV 726'   770         34     1 1 1   005   345565 003 Rev 1 X-87                                                                       NDE-VT GV 734'   460         34     1 1 1   005   345565 003 Rev 1 X-91B                                                                       NDE-VT GV 732'   570         34     1 1 1   005   345565 003 Revl1 X-92                                                                       NDE-VT GV 735w   570         34     1 1 1   005   345565 003 Rev 1 X-94                                                                       NDE-VT GV 734w   370         34     1 1 1   005   345565 003 Rev 1 X-7A                                                                       NDE-VT GV 740'   0&deg; +43       34     1 1 1   005   345565 003 Rev 1 X-7B                                                                       NDE-VT GV 740' 0&deg; +11       34     1 1 1   005   345565 003 Revl1 719'- 90&deg; to Drywell Exterior       GV 749'   180&deg;         35 X-31B                   GV 726'                                           NDE-VT 1620         35     1 1 1   005   345565 003 Rev 1 X-37B                                                                       NDE-VT GV 735'   1020         35     1 1 1   005   345565 003 IRev 1 X-38B                   GV 735'   1020         35     1 1 1   005   345565 003 IRev 1 X-80A                   GV 726'   1590         35     1 1 1   005   345565 003 Rev 1 X-80B                   GV 726'   1560         35     1 1 1   005   345565 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls                           Page 8 of 34
.m Repo.t.
t um NDE-VT X-63B GV 726' 730 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-64B GV 726' 770 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-87 GV 734' 460 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-91B GV 732' 570 34 1
1 1
005 345565 003 Revl1 NDE-VT X-92 GV 735w 570 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-94 GV 734w 370 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-7A GV 740' 0&deg; +43 34 1
1 1
005 345565 003 Rev 1 NDE-VT X-7B GV 740' 0&deg; +11 34 1
1 1
005 345565 003 Revl1 719'-
90&deg; to Drywell Exterior GV 749' 180&deg; 35 NDE-VT X-31B GV 726' 1620 35 1
1 1
005 345565 003 Rev 1 NDE-VT X-37B GV 735' 1020 35 1
1 1
005 345565 003 IRev 1 X-38B GV 735' 1020 35 1
1 1
005 345565 003 IRev 1 X-80A GV 726' 1590 35 1
1 1
005 345565 003 Rev 1 X-80B GV 726' 1560 35 1
1 1
005 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1-12t RIO Page 8 of 34


UNIT         12     RIO NDE-VT X-80C           GV 726'   1530     35       1 1 1 005 345565 003 Rev 1 NDE-VT X-86A           GV 735'   115&deg;     35       1 1 1 005 345565 003 Rev 1 ND E-V-T X-86B           GV 735'   1120     35       1 1 1 005 345565 003 Rev 1 NDE-VT X-88A           GV 721'   1140     35       1 1 1 005 345565 003 Revl1 NDE-VT X-91A           GV 726'   165&deg;     35       1 1 1 005 345565 003 Rev 1 719'- 1800 to
UNIT 12 RIO NDE-VT X-80C GV 726' 1530 35 1
___Drywell Exterior GV 749'   2700     36 I
1 1
NDE-VT X-5             GV 724'   2390     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-27A           GV 732'   2390     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-31A           GV 732'   2280     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-37A           GV 735'   2580     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-38A           GV 735'   2580     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-40A           GV 730'   2430     36       1 1 1 005 345565 003 Rev 1 NDE-VT X-40B           GV 729'   2480     36       1 1 1 005 345565 003 Rev 1 ND E-VT iX-40C         GV 735'   2430     36       1 1 1 005 345565 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xis                   Page 9 of 34
005 345565 003 Rev 1 NDE-VT X-86A GV 735' 115&deg; 35 1
1 1
005 345565 003 Rev 1 ND E-V-T X-86B GV 735' 1120 35 1
1 1
005 345565 003 Rev 1 NDE-VT X-88A GV 721' 1140 35 1
1 1
005 345565 003 Revl1 NDE-VT X-91A GV 726' 165&deg; 35 1
1 1
005 345565 003 Rev 1 719'-
1800 to
___Drywell Exterior GV 749' 2700 36 NDE-VT X-5 GV 724' 2390 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-27A GV 732' 2390 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-31A GV 732' 2280 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-37A GV 735' 2580 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-38A GV 735' 2580 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-40A GV 730' 2430 36 1
1 1
005 345565 003 Rev 1 NDE-VT X-40B GV 729' 2480 36 1
1 1
005 345565 003 Rev 1 ND E-VT iX-40C GV 735' 2430 36 1
1 1
005 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xis I
Page 9 of 34


J   th                                           10 UNIT'i -12         RIO II                    I - 7                                     III-               I I
J th UNIT'i -12 RIO I
I X-40D                  732'   2430                                             ULI-V I GV                    36       1 I 1   1     005 345565   003 Rev 1 X-55                  736'    2230                                            NDE-VT GV                    36      1        1    005  345565   003 Rev 1 X-56                  736'    219&deg;                                            NDE-VT GV                    36            1        005  345565 003 Rev 1 X-58A                  735'    2280                                          NDE-VT GV                    36                      005  345565 003 Rev 1 X-61A                  726'    2430                                          NDE-VT GV                      36                      005  345565 003 Rev 1 X-62A                  726'    2480                                          NDE-VT GV                      36      1              005  345565 003 Rev 1 X-63A            GV    726'  253'                                            NDE-VT 36          1          005 345565   003 Rev 1 X-64A            GV                              1                            NDE-VT 729'  2530 36            1        005  345565 003 Rev 1 X-28A            GV  739'    2480                                            NDE-VT 36              1      005  345565 1                          003 Rev 1 X-29A            GV  739'    2430                    1                      NDE-VT 36              1      005 1                  345565 003 Rev 1 79- 270to*                  1 Drywell Exterior  GV    749'  360'              1 37 1
I -
X-37C            GV  735'    2820                                          NDE-VT 37              1      005  345565 003 Rev 1 X-38C            GV  735'    282'                                          1NDE-VT 37              1      005  345565 003 Rev 1 726' , 294o X-60A            GV                                                          NDE-VT 37              1      005  345565 003 Rev i1 G:\ISI\IWL\outage U1-12 sched.xls Page 10 of 34
7 X-40D GV X-55 GV X-56 GV X-58A GV X-61A GV X-62A GV X-63A GV X-64A GV X-28A GV X-29A GV Drywell Exterior GV X-37C GV X-38C GV X-60A GV 732' 2430 736' 2230 736' 219&deg; 735' 2280 726' 2430 726' 2480 726' 253' 729' 2530 739' 2480 739' 2430 79-270to*
749' 360' 735' 2820 735' 282' 726', 294o 36 36 36 36 36 36 36 36 36 36 37 37 37 37 1
1 1
1 1
1 1
1 1
1 1
1 1
1 I
G:\\ISI\\IWL\\outage U1-12 sched.xls Page 10 of 34 10 1
005 1
005 005 005 005 005 005 005 1
005 1
005 1
005 1
005 1
005 III-I I
I I
ULI-V I 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 1NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev i1


I)
I)
I, UNIT 1 - 12          RIO
-X-85A GV 736'  
                -X-85A                                                                         GV   736'   31!190                                      NDE-VT 37    1 I  1  1  005  345565  003 Rev  1
-X-85B GV 736'  
                -X-85B                                                                         GV   736'   32:220                                      NDE-VT 37    1    1  1  005  345565  003 Rev  1
-X-88B GV 721' X-7C GV 740' X-7D GV 740' 749' Drywell Exterior GV 779' X-14 GV 750' X-9B GV 753' X-16B GV 763' X-20 GV 763' X-39B GV 763' X-45 GV 763' 749' Drywell Exterior GV 779' X-3B G:\\ISI\\IWL\\outage U1-12 sched.xis 31!
                -X-88B                                                                           GV   721'                                               NDE-VT 291)50      37    1        1  005  345565  003 Rev  1 X-7C                                                                                                           1                  NDE-VT GV   740' 00
32:
                                                                                                                -10      37    1        1  005  345565  003 Rev  1 X-7D                                                                                 0oo                      1                  NDE-VT GV   740'       -3      37                005  345565  003 Rev  1 749'   00oto Drywell Exterior                                                         GV   779'                     1        1 900&deg;      38 X-14                                                                       GV   750'   57'7-                                       NDE-VT 38          1      006  345565  003 Rev 1 1        1                NDE-VT X-9B                                                                      GV 753'   0&deg;0.
291 00 0oo 00o 90 57' 0&deg;0.
                                                                                                                +3     38         1     006  345565 003 Rev 1
: 0.
: 0.                 1       1               NDE-VT X-16B                                                                      GV  763'        +3      38          1     006  345565 003 Rev 1 1       1               NDE-VT X-20                                                                        GV  763'    21' 0      38          1      006  345565 003 Rev 1 X-39B                                                                                                                1               NDE-VT GV  763'        +6      38    1    1. 006  345565 003 Rev 1 X-45                                                                                                                1               ND E-VT GV  763'  900 -3 38          1      006  345565 003 Rev 1 749'  900 to Drywell Exterior                                                                                            1 GV    779'  1800&deg;      39 X-3B                                                                                                39                              NDE-VT 116                            006  345565  003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xis Page 11 of 34
21' 900 900 180 116 190 37 220 37
)50 37
-10 37
-3 37 to 0&deg; 38 7-38
+3 38  
+3 38 0
38
+6 38
-3 38 to 0&deg; 39 39 Page 11 of 34 UNIT 1 - 12 RIO I,
1 1
1 1
1 1
1 1
1 1
I 1
1 1
1 1
1 1
1
: 1.
1 1
1 1
1 1
1 1
1 1
1 005 005 005 005 005 006 006 006 006 006 006 006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1


I                                         UNIT i -     1 2 th RIO                                      I I                                                      F--7--7            i isFlptr1 1.Exarr                                                  WQK. j   Inp*
I isFlptr1 1.Exarr II
II 756'   1120                       111 12R006          NDE-VT X-3D                GV                      39                          345565  003 Rev 1 749'- 180' to Drywell Exterior          779'   2700 GV                      40
X-3D Drywell Exterior
                  'X-36                    750'                                                     NDE-VT GV          1900 40                           345565 11  1                   003 Rev 1 006 X-42                      750'    180'                                            NDE-VT GV                      40                            345565  003 Rev 1 11  1    006 X-3A                      756'  2480                                              NDE-VT GV                      40 11  1    006          003 Rev 1 X-3C                GV  756'    256o                                    345565  NDE-VT 40 11  1                  003 Rev 1 006 X-32B                GV  757'    232'                                    345565  NDE-VT 40 11  1  006            003 Rev 1 X-39A                GV  753'    1950                                    345565  NDE-VT 40 11    1  006            003 Rev 1 X-41                      754'    1860                1      1  1   006  345565  NDE-VT GV                      40 003 Rev 1 X-47                      757'    192'                1     1  1  006  345565  NDE-VT GV                    40 003 Rev 1 X-57                      755'    1900                1 1 11  11  006 006  345565  NDE-VT GV                    40 003 Rev 1 X-66B                GV  757'    2280                1    1    1  006  345565  NDE-VT 40 003 Rev 1 X-81 B              GV  756'  2360                1    1    1  006  345565  NDE-VT 40 003 Rev 1 X-82B                                                                    345565  NDE-VT 40 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 12 of 34
'X-36 X-42 X-3A X-3C X-32B X-39A X-41 X-47 X-57 X-66B X-81 B X-82B GV GV GV GV GV GV GV GV GV GV GV GV GV I
WQK. j Inp*
756' 1120 749'-
180' to 779' 2700 750' 1900 750' 180' 756' 2480 756' 256o 757' 232' 753' 1950 754' 1860 757' 192' 755' 1900 757' 2280 756' 2360 39 40 40 40 40 40 40 40 40 40 40 40 40 40 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 12 of 34 UNIT i - 1 2 th RIO I
1 1 1
12R006 1 1 1
006 1 1 1
006 1 1 1
006 1 1 1
006 1 1 1
006 1 1 1
006 1
1 1
006 1
1 1
006 1
1 1
006 1
1 1
006 1
1 1
006 1 1 1
006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 F--7--7 i


I)
lo X-84B X-59B X-65B Drywell Exterior X-32A X-66A
UNIT -, -     1 2 th RIO
-X-81A X-82A X-84A X-26 X-59A X-65A X-9A X-16A GV GV GV GV GV GV GV GV GV GV GV GV GV GV G:\\ISI\\IWL\\outage U1-12 sched.xls Page 13 of 34 I)
                                                                                . . ..::: : * :* *;:: :*:* :*:**:* *;*` :* :
UNIT -, - 12 th RIO
* IX-84B 2440 I
:::: :::: :::: :::: : : :*:*::*: :::* *:*: ::: : * :* *;:: :*:* :*:* *:* *;* ` :* :
                                                                                                                                                                                .. *L.F-v 1 GV                    756'             40       1   1   1 006 345565  003 Rev 1 X-59B                                                                            GV                                                                        NDE-VT 775'    2280      40        1   1 1   006 345565  003 Rev 1 X-65B                                                                            GV                                                                        NDE-VT 768'    2280      40        1   1 1   006 345565 003 Rev 1 749,    2700 to Drywell Exterior                                                                GV 779'    3600      41 X-32A                                                                          GV                                                                          NDE-VT 756'    3090      41                1  006  345565  003 Rev 1 1  1                  :NDE-VT X-66A                                                                            GV                            305&deg; 756'              41                1  006  345565  003 Rev 1 1  1                    NDE-VT
* I 756' 775' 768'
                  -X-81A                                                                          GV                    756'    2930      41                1  006  345565  003 Rev 1 X-82A                                                                                                                              1   1                  N D E-VT GV                    756'    2970      41              1  006  345565  003 Rev 1 X-84A                                                                                                                              1  1                  NDE-VT GV                    756'    3010      41              1  006  345565  003 Rev 1 X-26                                                                                                                                1  1                  NDE-VT GV 772'      780      41              1  006  345565  003 Rev 1 X-59A                                                                                                                                1  1                  NDE-VT GV 775'      305 0    41              1  006  345565  003 Rev 1 X-65A                                                                                                                                1  1 GV                    768'                                                  NDE-VT 305 0    41              1  006  345565  003 Rev 1 X-9A                                                                                                                                1  1                  NDE-VT GV                    753' 00-3      41              1  006  345565  003 Rev 1 X-16A                                                                                                                                1  1                  NDE-VT lo                                                                              GV                    763' 0_-2      41              1  006  345565  003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 13 of 34
: 749, 779' 756' 756' 756' 756' 756' 772' 775' 768' 753' 763' 2440 2280 2280 2700 to 3600 3090 305&deg; 2930 2970 3010 780 3050 3050 00-3 0_-2 40 40 40 41 41 41 41 41 41 41 41 41 41 41 1
1 1
1 1
1 1
1 1
1 1
1 I
1 1
1 1
1 1
1 1
1 1
1 1
1 006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 1
006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565
*L. F-v 1
003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1
:NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N D E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N DE-VT 003 Rev 1


UNIT .4         2 th RIO Exami~i iiiiiiiiii D.         .i.........                                                      I at  12R It4       .........                                                  Dwg.              P.riod          wQ#
UNIT.4 2 th RIO D.  
wa &#xfd;I JI M
.i It4 Exami~i iiiiiiiiii wa &#xfd;I JI M  
                                                                                                                                        ....i
.R.e...
                                                                                                                                  .R.e...
Dwg.
00 to Drywell Exterior                       791'                                       no access                  NDE-VT GV        791'             900       42           1   this area   007  345565  003 Rev 1 Drywell Exterior                                      900 to no access                 NDE-VT 1800        43        1    this area   007  345565  003 Rev 1 SDrywell Exterior                                    1800 to no access                 NDE-VT 2700      44            1  this area   007  345565  003 Rev 1 Drywell Exterior                                    2700 to no access                 NDE-VT 3600      45      1    1  this area   007   345565 003 Rev 1 00  to Drywell Exterior            GV        794'                                                                  NDE-VT 900      46       1                   008   345565 003 Rev  1 900 to Drywell Exterior                                                                                            NDE-VT 1800        47     1     1       1     008   345565 003 Rev  1 1800 to Drywell Exterior                                                                                            ND E-VT 270&deg;        48     1   1       1 Drywell Exterior                    H                3600        49     1   1 008  345565 003 Rev NDE-VT 1
I at P.riod Drywell Exterior Drywell Exterior SDrywell Exterior Drywell Exterior GV Drywell Exterior GV Drywell Exterior Drywell Exterior Drywell Exterior 791' 791' 794' 00 to 900 900 to 1800 1800 to 2700 2700 to 3600 00 to 900 900 to 1800 1800 to 270&deg; 3600 Examination Category: E-A, Containment Surfaces 42 1
1      008 345565 003 Rev  1 Examination Category: E-A, Containment Surfaces 360&deg; E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas 704D-I 0'5to Drywell Interior           GV         719'           900                                                   NDE-VT 50       1   1       1     009   345566  003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 14 of 34
43 1
44 1
45 1
1 no access this area no access this area no access this area no access this area 12R
007 345565 007 345565 007 345565 007 46 1
008 345565 47 1
1 1
008 345565 48 1
1 1
008 345565 49 1
1 1
008 345565 E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas 704D-I 0'5to Drywell Interior GV 719' 900 50 1
1 1
009 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 14 of 34 wQ#
345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 345566 360&deg; H
i


I4                                       UNIT        , - 1 2 th RIO I     I                I I        I I
I4 I
NDE-VT X-34B              GV    704' I    190  I    50                  009  345566 003 Rev 1 1
I I
X-35A                                                                            NDE-VT GV   717'     500       50                       345566 1   1   009         003 Rev 1 1
X-34B X-35A X-35B X-35C X-35D X-35E X-35F X-49B X-1 04F X-83B X-93 X-100H X-104H Drywell Interior GV GV GV GV GV GV GV GV GV GV GV GV GV 719'-
X-35B                                                                          NDE-VT GV    717'    480        50                        345566 1   1     009         003 Rev 1 1
704' 717' 717' 717' 717' 717' 717' 705' 711' 705' 717' 711' 711' 704' 719' 190 500 480 460 440 410 390 440 36' 150 370 530 220 900 to 1800 51 1
X-35C                                                                          NDE-VT GV    717'    460        50                        345566 1   1     009         003 Rev 1 1
50 50 50 50 50 50 50 50 50 50 50 50 50 51 I
X-35D                                                                            4NDE-VT GV  717'      440        50                        345566 1   1     009         003 Rev 1 X-35E                                                                          NDE-VT GV  717'      410        50    1   1   1   009   345566 003 Rev 1 X-35F                                                                          NDE-VT GV  717'      390        50    1                 345566 1   1   009          003 Rev 1 X-49B                                                                          ND E-VT GV  705'      440        50    1  1  1    009  345566 003 Rev 1 X-1 04F            GV                                                          NDE-VT 711'      36'        50      1  1  1    009  345566 003 Rev 1 X-83B              GV                                                          NDE-VT 705'      150        50      1  1  1    009  345566 003 Rev 1 X-93              GV                                                          NDE-VT 717'      370        50          1  1    009  345566 003 Rev 1 1                          NDE- T X-100H            GV  711'                              1 1    009 530        50                        345566 003 Rev 1 1
G:\\ISI\\IWL\\outage U 1-12 sched.xls Page 15 of 34 UNIT, - 12 th RIO 1
X-104H            GV                                      1 1    009 711'    220        50                        345566 003 Rev 1 704'    900 to Drywell Interior        719'                51                                  ND E-VT I 719'-    1800                            009  345&#xfd;566(
1 1
51      1                          003 Rev 1 G:\ISI\IWL\outage U 1-12 sched.xls Page 15 of 34
1 1
1 1
1 1
1 1
I 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 1
1 009 009 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345&#xfd;566(
I I
I I
NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 4NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-T 003 Rev 1 003 Rev 1 ND E-VT 003 Rev 1


UNIT,12     T1 2 th RIO I
G:\\ISI\\IWL\\outage U1-12 sched.xls Page 16 of 34 T
                    .X-11         GV   708'   1470                     I                 NDE-VT 51 1  1    009   345566   003 Rev 1
1 2 th UNIT,12 RIO
                  -X-12            GV    710'  1760      51                              NDE-VT 1  1    009   345566   003 Rev 1 X-1 3B          GV    710'  1610&deg;                                      NDE-VT 51 1  1    009   345566   003 Rev 1
.X-11  
                  -X-15            GV    709'  1240      51                              NDE-VT 1        009   345566   003 Rev 1
-X-12 X-1 3B
                  -X-18            GV    709'  1270      51                              NDE-VT 1  1    009   345566   003 Rev 1
-X-15
                  -X-19            GV    709'  120&deg;      51                              NDE-VT 1  1    009   345566   003 Rev 1 X-30B          GV    705'  1320                                        NDE-VT 51 009   345566   003 Rev 1 X-33B          rGV    705'                      1                      NDE-VT 1250      51 1    009   345566   003 Rev 1 X-34A          GV    705'                      1                      NDE-VT 1540      51 009   345566   003 Rev 1 X-50B            GV                              1  1                  NDE-VT 705'  1420      51                009   345566   003 Rev 1 X-51 B          GV    705,                      1                      NDE-VT 145&deg;      51                009   345566 1                  003 Rev 1 X-52B            GV                                                      NDE-VT 705'  1370      51 1    009   345566 .003 Rev 1 X-83A            GV    705'                                              NDE-VT 150&deg;      51                009   345566 1                      003 Rev 1 X-90D                                                                    NDE-VT GV    711'  1410      51 1        009   345566   003 Rev 1 X-90E            GV                                                      NDE-VT 1711'  137&deg;      51                009 _345566 1003 Rev,,
-X-18
G:\ISI\IWL\outage U1-12 sched.xls Page 16 of 34
-X-19 X-30B X-33B X-34A X-50B X-51 B X-52B X-83A X-90D X-90E GV 708' GV 710' GV 710' GV 709' GV 709' GV 709' GV 705' rGV 705' GV 705' GV 705' GV
: 705, GV 705' GV 705' GV 711' GV 1711' 1470 51 1760 51 1610&deg; 51 1240 51 1270 51 120&deg; 51 1320 51 1250 51 1540 51 1420 51 145&deg; 51 1370 51 150&deg; 51 1410 51 137&deg; 51 I
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 I
NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566.003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009
_345566 1003 Rev,,


        )                                               UNIT 1 - 12              RIO I   I                                        I I
)
NDE-VT X-90F                GV      711'        1330      51                      009  345566  003 Rev 1 NDE-VT X-48A                GV     705'         157'       51             1   1   009  345566  003 Rev 1 1
I I
704'        1800 to                    1                       NDE-VT 1
I X-90F X-48A Drywell Interior X-6 (CRD Hatch)
Drywell Interior      GV      719'        2700      52                      009   345566 003 Rev 1 1
X-10 X-13A X-17 X-23 X-24 X-25 X-50A X-72A X-72B Drywell Interior G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO GV GV GV GV GV GV GV GV GV GV GV GV GV GV 704' 719' 711' 705' 704' 719' 718' 714' 710' 710' 709' 709' 710' 705' 704' 704' 1330 157' 1800 to 2700 2160 2090 1990 2470 1860 1830 2360 2150 2290 231&deg; 2700 to
NDE-VT X-6 (CRD Hatch)      GV      718'        2160      52            1        009  345566 003 Rev   1 1        1                   NDE-VT X-10                  GV      714'        2090      52            1        009  345566 003 Rev   1 1        1 NDE-VT X-13A                GV      710'        1990      52            1        009  345566 003 Rev   1 1        1                   NDE-VT X-17                  GV      710'        2470      52            1        009  345566 003 Rev   1 1        1 NDE-VT X-23                  GV      709'        1860      52            1        009  345566 003 Rev   1 1
.3Ri0&deg; 51 51 52 52 52 52 52 52 52 52 52 52 52 1
NDE-VT X-24                  GV      709'        1830      52        1    1        009  345566 003 Rev   1 X-25                                                                      1 NDE-VT GV      710'        2360      52        1    1        009  345566 003 Rev   1 1
1 1
NDE-VT X-50A                  GV      705'        2150      52        1    1        009  345566 003 Rev   1 1
1 1
INDE-VT X-72A                  GV      704'        2290      52        1   1        009  345566 003 Rev   1 1
1 1
704'        231&deg;                                             JNDE-VT IX-72B              -L
1 1
                                    -t GV Ii          iIi        iI 52 I
1 1
1 009  345566 003 Rev  1 704'        2700 to tNDE-VT Drywell Interior      GV      719'        .3Ri0&deg; I-                    I . .      . .. u  I   vv    1 &#xfd;53%3    I . II      I II 009 I 345566 003  Rev 1 iI                  1(
1 1
I G:\ISI\IWL\outage U1-12 sched.xls                                  Page 17 of 34
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
009 009 009 009 009 009 009 009 009 009 009 009 009 009 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 i
I.
II I.
.. u I
vv 1
%3 I -
I NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 INDE-VT 003 Rev 1 JNDE-VT 003 Rev 1 NDE-VT 003 Rev 1
&#xfd;53 Page 17 of 34 i
i I
I i
iI
-t I
-L I
I t
I I
I I
1(
I I


I4                                           UNIT,      - 12  th  RIO
I4 J X-30A
                  -T 53        1  1                                    NDNUI-T 003 Rev 1_
_X-33A X-49A X-51 A X-52A X-90A X-90B X-90C xX-100G X-104E X-104G Drywell Interior X-8 X-21 SG___V 710--
SG___V   710--   322__0_                     1        009      345566
322__0_
_X-33A              GV     708'   3270                                                         NDE -AVT J X-30A                                        53        1  1  1                              003 Rev 1 009      345566 X-49A              GV     704'     3270                                                         NDE-VT 53      1    1  1        009      345566      003 Rev 1 X-51 A            GV     704'     324&deg;                                                         NDE-VT 53      1  1  1          009      345566      003 Rev 1 X-52A              GV     708'     323'                                                         NDE-VT 53        1  1  1        009      345566      003 Rev 1 X-90A              GV     711'     3280                                                         NDE-VT 53                1        009      3455660      003 Rev 1 X-90B              GV     711'   3320       53      11                009      345566        NDE-VT 003 Rev 1 531                        009      345566      0NDE-VT X-90C              GV     711'   3360 003 Rev 1 531                009      345566    0 xX-100G          GV     711'     3130 ND-E-VT X-104E                                        53              1          010      345566    C003 Rev 1 PGV       706'   3480 KIDE-VT X-104G            GV     711'   3530                                                           003 Rev 1 53        1  1  1          010      345566    C NIDE-VT
GV 708' 3270 GV 704' 3270 GV 704' 324&deg; GV 708' 323' GV 711' 3280 GV 711' 3320 GV 711' 3360 GV 711' 3130 PGV 706' 3480 GV 711' 3530  
                                            -&#xfd; -19'- 0&deg; to                                                         003 Rev 1 Drywell Interior  GV     738'     90&deg; 54        1                                        NDE-VT 1  1        010      345566    0 X-8                GV     73 1'     00                                                           D03 Rev 1 NDE-VT X-21            FGV     7 344'   400&deg;0     541                                                )03 Rev 1
-&#xfd; -19'-
                                                                                        . 010      345566 O0 G:\ISI\IWL\outage U1-12 sched.xls Page 18 of 34
0&deg; to GV 738' 90&deg; GV 73 1' 00 FGV 7 344' 400&deg;0 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 18 of 34
: UNIT,
- 1 2 th RIO
-T 53 1
1 1
009 345566 53 1
1 1
009 345566 53 1
1 1
009 345566 53 1
1 1
009 345566 53 1
1 1
009 345566 53 1
009 3455660 53 11 009 345566 531 009 345566 0
531 009 345566 0
53 1
010 345566 C
53 1
1 1
010 345566 C
54 1
1 1
010 345566 0
541 010 345566 O0 NDNUI-T 003 Rev 1_
N DE -AVT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND-E-VT 003 Rev 1 KIDE-VT 003 Rev 1 NIDE-VT 003 Rev 1 NDE-VT D03 Rev 1 NDE-VT
)03 Rev 1


AN UNIT'i -       1 2 th RIO I
AN UNIT'i - 1 2 th RIO ili~iiiii!i i ! i NDE-VT X-22 GV 734' 430 54 1
                                                          .... ..                      .............      ili~iiiii!i i!i NDE-VT X-22                     GV     734'     430       54       1   1       1       010     345566 003 Rev 1 NDE-VT X-27B                     GV     726'     610       54       1   1         1       010     345566 003 Rev 1 NDE-VT X-28B                     GV     729'     610       54       1   1       1       010     345566 003 Rev 0 X-29B                                                                                               NDE-VT GV     732'     610       54       1 1         1       010     345566 003 Rev 1 X-40E                     GV                                                                         NDE-VT 729'     770       54       1   1       1       010     345566 003 Rev 1 X-40F                     GV                                                                         NDE-VT 729'     73       54       1   1       1       010     345566 003 Rev 1 2 6'             541           111                 0N             DE VT XV4 0 7GG        120 GGV   736'     39       54       1   1         1       010     345566   003 Rev 1 NDE-VT X-540                     GV     73'     651       54       1   1         1       010     345566   003 Rev 1 X-58B                     GV     735'                                                               NDE-VT 60       54       1   1         1       010     345566   003 Rev 1 NDE-VT X-46                     GV     727'     00       54       1   1         1       010     345566 X-4B               V   72'     65&deg;       5401 003 Rev 1 345566   003 Rev 1 X-48 GV   732'     650NDE-VT X-3G                 3'     3&deg;       54       1   1         1       010     345566   003 Rev 1 36'   390         4       1   1       1NDE-VT X-5 X-53GV G     76'     51&deg;       54       1             1       010     345566   003 Rev 1 X-8-G-35      X-54GV       36'   510NDE-VT 5       54       1   1         1       010     345566   003 Rev 1 IX-60B                     GV . 735'. 61 &deg;       541           11               010     34 5 6 NDE-V 0 e v1 G:\ISI\IWL\outage U1-12 sched.xls                               Page 19 of 34
1 1
010 345566 003 Rev 1 NDE-VT X-27B GV 726' 610 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-28B GV 729' 610 54 1
1 1
010 345566 003 Rev 0 NDE-VT X-29B GV 732' 610 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-40E GV 729' 770 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-40F GV 729' 73 54 1
1 1
010 345566 003 Rev 1 X 4 0 GG V
7 2 6' 120 541 111 0N D E VT GGV 736' 39 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-540 GV 73' 651 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-58B GV 735' 60 54 1
1 1
010 345566 003 Rev 1 NDE-VT X-46 GV 727' 00 54 1
1 1
010 345566 003 Rev 1 X-4B V
72' 65&deg; 5401 345566 003 Rev 1 X-48 GV 732' 650NDE-VT X-3G 3'
3&deg; 54 1
1 1
010 345566 003 Rev 1 X-53GV 36' 390 4
1 1
1NDE-VT X-5 G
76' 51&deg; 54 1
1 010 345566 003 Rev 1 X-54GV 36' 510NDE-VT X-8-G-35 5
54 1
1 1
010 345566 003 Rev 1 NDE-V IX-60B GV. 735'.
61 &deg; 541 11 010 34 5 6 0 e v 1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 19 of 34 I


I At UNIT '1-                   2 th               RIO                                                             I i                               I  S              *  -.-        -    -                    ...........        _
I I
1st      ..
S Elix Exam X-619 X-62B X-63B X-64B X-87 X-91 B X-92 X-94 X-37D X-38D Drywell Interior X-31B X-80A X-80B GV GV GV GV GV GV GV GV GV GV GV GV
2......
.lig 726' 726' 726' 726' 734' 732' 735' 734' 735' 735' 719' 738' 726' 726' 650 690 730 770 460 570 570 370 780 780 90&deg; to 1800 1620 1590 54 54 54 54 54 54 54 54 54 54 55 55 55 55 1st Period 1
Itr      .. . .
1 1
Elix  Exam                                  .lig                                  Im Period              WO#
1 1
U":r-                                                                       o L.-
1 1
zz=              ....... .....
1 1
T INDS.                    S.................. ..........
1 1
ii                       ,.......30 W.,&#xfd;-U . a . .. .. ... ..
1 1
                                                                                                                        &X=           1-Report #x*:        i 14 Tmmb    Mii    m 46i
UNIT ' 1-2 th RIO i
                                                                          -F                                          17 IT Irisp 1
1 1
X-619                        GV      726'      650                                                                          010      345566 54                                    1            1                        003 Rev 1 NDE-VT 1
1 1
X-62B                          GV      726'    690                                                                            010    345566    003 Rev 1 54                                    1            1 NDE-VT X-63B                          GV      726'    730                                                                            010    345566  003 Rev 1 54                        1            1 NDE-VT X-64B                          GV                                                                                              010 726'    770                54                                                                  345566  003 Rev 1 1            1          1 NDE-VT X-87                          GV                                                                                              010    345566  003 Rev 1 734'    460                54                      1            1          1 NDE-VT X-91 B                        GV                                                                                              010 732'    570                54                                                                  345566  003 Rev 1 1            1          1 NDE-VT X-92                          GV                                                                                              010 735'      570                54                                                                  345566  003 Rev 1 1            1 NDE-VT X-94                          GV                                                                                      1 734'      370                                                                          010      345566  003 Rev 1 54                        1            1 NDE-VT X-37D                        GV                                                                                              010 735'      780              54                                                                    345566  003 Rev 1 1            1 NDE-VT X-38D                        GV                                                                                              010 735'      780              54                                                                  345566    003 Rev 1 1
1 1
1 719'                                                  1                                                    NDE-VT 90&deg;  to Drywell Interior              GV                                                                                      1      010    345566    003 Rev   1 738'    1800              55                                    1 1                                                    NDE-VT X-31B                        GV                                                                                              010    345566  003 Rev   1 726'      1620              55                                    1 1                                                    NDE-VT X-80A                                                                                                                          010    345566 726'      1590                                                                                            003 Rev   1 1
1 1
55                                                                            NDE-VT 1                                  010 X-80B                                                            55                                                                    345566  003 Rev   1 G:\ISI\IWL\outage U1-12 sched.xls Page 20 of 34
1 1
1 1
1 WO#
1 1
1 1
1 1
1 1
G:\\ISI\\IWL\\outage U1-12 sched.xls Page 20 of 34 2......
Itr
zz=
I 010 010 010 010 010 010 010 010 010 010 010 010 010 010 Irisp
-F 17 IT 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 L.-
Report #x*:
i o Im INDS. U": r-T 14Tmmb Mii m
46i S.
ii  
..... 30 W.,&#xfd;- U a &X=
1-003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 At


UNIT       -  12 th RIO I
I UNIT 1
I     I                 I                                         I   I     I         I         - I I
2 th RIO X-80C X-86A X-86B X-88A X-91 A X-37B X-38B Drywell Interior X-5 X-27A X-31A X-40A X-40B
X-80C            I GV    726'      1530      55      1 I  1    1    010   345566 003 Rev 1 NDE-VT X-86A              GV    735'      1150 55      1    1    1    010    345566 003 Rev 1 X-86B              GV  735'      112'                                            ND E-VT 55      1    1    1    010    345566 003 Rev 1 NDE-VT X-88A              GV  721'      1140                                    345566 003 Rev 1 55    1    1  1    010 NDE-VT X-91 A            GV  726'      1650                                    345566 003 Rev 1 55                    010 NDE-VT X-37B              GV  735'      1020                                    345566 003 Rev 1 55                    010 NDE-VT X-38B              GV  735'      102o              1    1    1          345566 003 Rev 1 55                    010 7--&#xfd;,-19' 180&deg; -to          1    1    1                  NDE-VT Drywell Interior  GV  738'      2700                                    345566 003 Rev 1 56                    010 1    1    1                  NDE-VT X-5                GV  724'      2390                                    345566 003 Rev 1 56                    010 1                             NDE-VT X-27A              GV                                    1    1 732'      239 &deg;                                  345566 003 Rev 1 56                    010 1                            NDE-VT 7321                            1    1 X-31A              GV            228&deg;                                    345566 003 Rev 1 56                    010 1   1                        NDE-VT GV                                        1 X-40A                    730'      2430                                    345566 003 Rev 1 56                    010 1                            NDE-VT X-40B                    729,                            1    1 GV                                                    345566 003 Rev 1 56                    010 NDOE-VT
;X-400 C I
                  ;X- 400 C            GV 1735'                                              345566 003 Rev 1 56                    010 G:\ISI\lWL\outage Ul-12 sched.xls Page 21 of 34
GV 726' GV 735' GV 735' GV 721' GV 726' GV 735' GV 735' 7--&#xfd;, -19' GV 738' GV 724' GV 732' GV 7321 GV 730' GV
: 729, GV 1735' 1530 1150 112' 1140 1650 1020 102o 180&deg; -to 2700 2390 239 &deg; 228&deg; 2430 55 55 55 55 55 55 55 56 56 56 56 56 56 56 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
G:\\ISI\\lWL\\outage Ul-12 sched.xls Page 21 of 34 I
I I
I I  
- I I
I I
I 010 010 010 010 010 010 010 010 010 010 010 010 010 010 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 ND E-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDOE-VT 345566 003 Rev 1


1I                                                                 UNIT        ,    12th RIO Is I MI.                               -i.4l I.................... '..... ...
1I I
                                            ,JII 1 xm t~PIIV~       am           j   Dg.       l   &#x17d;2     Rpot I   I X-40D I 1         1 2FidInnnKY
MI.  
                                                                                                                . . ......          NDE-VT GV    732'      2430        56                                345566 003 Rev 1 010 NDE-VT X-55                                      GV    736'      2230                                          345566 56                    010                  003 Rev 1 X-56                                                                                                            NDE-VT GV    736'      2190      56                                  345566 003 Rev 1 010 X-58A                                                                                                            NDE-VT GV    735'                  56                    010 2280                                          345566 003 Rev 1 NDE-VT X-61A                                    GV    726'      243o      56                    010        345566   003 Rev 1 NDE-VT X-62A                                    GV    726'      248'        56                    010        345566   003 Rev 1 NDE-VT X-63A                                    GV  726'      253'        56          1  1      010        345566 003 Rev 1 1
-i.4l I....................  
X-64A                                                                                                            NDE-VT GV  729'      2530        56          1  1      010        345566 '003 Rev 1 1
,JII t~PIIV~
X-37A                                                                                                            NDE-VT GV  735'      2580        56          1  1      010        345566 003 Rev 1 X-38A                                    GV                                                                    NDE-VT 735'      2580        56                    010        345566 003 Rev 1 719'    2-&#xfd;70&deg; to Drywell Interior                        GV    738'      360*        57                    010        345566 003 Rev 1 X-60A                                    GV                                                                      NDE-VT 726'      2940        57                    010        345566 003 Rev 1 NDE-VT X-85A                                    GV              3190                                            345566 003 Rev 1 NDE-VT X-85B                                                                                        010 345566 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 22 of 34
1xm am j
Dg.
l  
&#x17d;2 Rpot I 1 1
2FidInnnKY I
I X-40D X-55 X-56 X-58A X-61A X-62A X-63A X-64A X-37A X-38A Drywell Interior X-60A X-85A X-85B GV GV GV GV GV GV GV GV GV GV GV GV GV 732' 736' 736' 735' 726' 726' 726' 729' 735' 735' 719' 738' 726' 2430 2230 2190 2280 243o 248' 253' 2530 2580 2580 2-&#xfd;70&deg; to 360*
2940 3190 56 56 56 56 56 56 56 56 56 56 57 57 1
1 1
1 1
1 1
1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 22 of 34 UNIT,
12th RIO Is 010 010 010 010 010 010 010 010 010 010 010 010 010 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 '003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1


UNIT       ,-     1 2 th RIO
UNIT,-
                                                                                                                              )
1 2 th RIO Itei'
Ion, Itei' X-88B X-37C sflptI GV GV 721' 735' A=
sflptI
2950 2820&deg; 57 57 1
X-88B X-37C X-38C Drywell Interior X-7A X-7B X-7D X-7C X-14 Drywell Interior Drywell Interior X-28A X-29A 1st Perloc GV 721' GV 735' GV 735' 7--38';.
1 F......
GV 752' GV 740' GV 740' GV 740' GV 740' GV 750' GV 752' 738' GV 752' GVV 7'39__*'
1st Perloc L1 1
G__V 739__'
RC 010 010 345566 345566 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 X-38C                GV    735'                                                              NDE-VT 2820                                  010  345566 57        1          1 1                          003 Rev 1 7--38'; .
A=
Drywell Interior    GV    752'        900      58          1  1                          NDE-VT 1    011  345566  C003 Rev 1 X-7A                GV    740'        00 +3      58        1    1                          NDE-VT 011  345566  C)03 Rev 1 X-7B                  GV    740'                    58                  1                    NDE-VT 00 +11                  1 1          011  345566  C)03 Rev 1 X-7D                  GV  740'                    61        1        1                      NDE-VT 00-3                      1          011  345566  NC003 Rev 1 X-7C                  GV  740'                    61                  1      011  345566  0JDE-VT 00 -10                  1                              K 1                          D03 Rev 1 X-14                  GV  750'                    58        1        1      011  345566  0JDE-VT 570
2950 2820&deg; 2820 900 00 +3 00 +11 00-3 00 -10 570 90' to 1800 180' to 2700 2480 2430 G:\\ISI\\IWL\\outage Ul-12 sched.xls Page 23 of 34
                                                                                                                    )03 Rev 1 90' to                          1                    N Drywell Interior    GV    752'                    59        1              011  345566  0IDE-VT 1800                        1 03 Rev 1 738'        180' to                          1                    N Drywell Interior    GV    752'                    60        1              011  345566  N 0iDE-VT 2700 03 Rev 1 X-28A                GVV  7'39__*'                60        1__      1      011  345566 01DE-VT 2480 N03 Rev 1 X-29A                G__V 739__'      2430 1      011  345566 0(DE-VT 03 Rev 1 i G:\ISI\IWL\outage Ul-12 sched.xls Page 23 of 34
)
: Ion, 57 1
57 1
57 1
58 1
58 1
58 1
61 1
61 1
58 1
59 1
60 1
60 1_ _
1 1
1 1
1 1
1 F.....
RC L 1 1
1 1
1 1
1 1
1 1
1 1
010 345566 010 345566 010 345566 011 345566 C 011 345566 C
011 345566 C
011 345566 C
N 011 345566 0 K 011 345566 0
N 011 345566 0
N 011 345566 0i N
011 345566 01 N
011 345566 0(
NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT  
)03 Rev 1 NDE-VT  
)03 Rev 1 NDE-VT 003 Rev 1 JDE-VT D03 Rev 1 JDE-VT  
)03 Rev 1 IDE-VT 03 Rev 1 DE-VT 03 Rev 1 DE-VT 03 Rev 1 DE-VT 03 Rev 1 i


                                                            )-   th UNIT ,12               RIO 1      7 fill" 1: W Dwg.                      ........................
X-36 GV X-42 GV Drywell Interior GV Drywell Interior GV X-9B GV X-16B GV X-20 GV X-39B GV X-45 GV Drywell Interior GV X-3B GV X-3D GV Drywell Interior GV G:\\ISI\\IWL\\outage U1-12 sched.xls
60                                                -7NDE-VT X-36              GV  750'   1900                 1  1  1    011    345566 003 Rev 1 X-42                                      60                                                  NDE-VT GV  750'   1800                 1  1  1    011    345566 003 Rev 1 738'- 2700 to Drywell Interior                          61                                                  NDE-VT GV  752'   3600                         1  011    345566                  003 Rev 1 752'-   00&deg;to                   1 Drywell Interior                          62                                                  NDE-VT GV  767'     900                1       1   012   345566                 003 Rev 1 62          1                                       NDE-VT X-9B              GV  753'    00 +3                1      1    012    345566 003 Rev                 1 62          1                                     NDE-VT X-16B              GV  763'    00 +3                      1    012    345566 003 Rev                 1 62      1                                         NDE-VT X-20              GV  763'    210                    1  1    012    345566 003 Rev                 1 62        1                                         NDE-VT X-39B            GV  763'    00 +6                    1  1    012  345566 003 Rev                   1 X-45                                      62        1                                         NDE-VT GV  763'  90  o-3                  1  1    012    345566 003 Rev                   1 752'-   90&deg;to                1 Drywell Interior  GV                      63                                                  NDE-VT 767'    1800                        1    012    345566                003 Rev 1 X-3B              GV                      63                                                  NDE-VT 757'    116'                        1    012    345566                003 Rev 1 X-3D              GV                      63                                                  NDE-VT 756'    1120                        1    012    345566                003 Rev 1 Drywell Interior J152'- 1-80 0 to GV                                            012                          NDE-VT 767'    2700_      64 345566                  003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 24 of 34
)-
th UNIT,12 RIO 750' 1900 750' 1800 738'-
2700 to 752' 3600 752'-
00&deg;to 767' 900 753' 00 +3 763' 00 +3 763' 210 763' 00 +6 763' 90 o-3 752'-
90&deg;to 767' 1800 757' 116' 756' 1120 J152'-
1-800 to 767' 2700_
Dwg.
60 60 61 62 62 62 62 62 62 63 63 63 64 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 fill" 1 : W 1
011 1
011 1
011 1
012 1
012 1
012 1
012 1
012 1
012 1
012 1
012 1
012 012 Page 24 of 34
-7 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 1
7


I)                                           UNIT 0t
I)
                                                                  -12" RIO I        I I
I I
NDE-VT X-3A              GV       756'       248       64       1 1 1 012 345566 003 Rev 1 GV                                                        NDE-VT X-3C                      756'        2560      64            012 345566 003 Rev 1 GV                                                        NDE-VT X-32B                      757'      2320        64            012 345566 003 Rev 1 GV                                                        NDE-VT X-39A                      753'        1950      64            012 345566 003 Rev 1 X-41              GV      754'                                            NDE-VT 1860      64      1 1 1 012 345566 003 Rev 1 X-47              GV                                                        NDE-VT 757'        1920      64      1 1 1 012 345566 003 Rev 1 X-57              GV      755'                                            NDE-VT 1900      64            012 345566 003 Rev 1 X-66B              GV                                                        NDE-VT 757'      2280        64            012 345566 003 Rev 1 1 1                    1 X-81 B            GV                                                        NDE-VT 756'      2360        64            012 345566 003 Rev 1 1 1                    1 X-82B              GV                                                        NDE-VT 756'      2400        64            012 1 1    345566 003 Rev 1 X-84B              GV      756'                            1                NDE-VT 2440        64            012 345566 003 Rev 1 7-5-2'      2700 to                                NDE-VT Drywell Interior  GV      767' 3600      65                345566 012        003 Rev 1 X-32A              GV                                                        NDE-VT 309 0      65            012 345566 003 Rev 1 IX-66A            GV                  3050                                  NDE-VT I   II .  - - I II 3Q50 II      II      012 345566 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 25 of 34
X-3A X-3C X-32B X-39A X-41 X-47 X-57 X-66B X-81 B X-82B X-84B Drywell Interior X-32A IX-66A GV GV GV GV GV GV GV GV GV GV GV GV GV GV 756' 756' 757' 753' 754' 757' 755' 757' 756' 756' 756' 7-5-2' 767' 3Q5 0
248 2560 2320 1950 1860 1920 1900 2280 2360 2400 2440 2700 to 3600 3090 3050 64 64 64 64 64 64 64 64 64 64 64 65 65 65 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 25 of 34 0t UNIT
-12" RIO 012 012 012 012 012 012 012 012 012 012 012 012 012 012 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 I
I II I
I I
II I
I


UNIT,       - 1 2 thRIO
X-81A GV X-82A GV X-84A GV X-9A GV X-16A GV Drywell Interior GV Drywell Interior GV Drywell Interior GV X-59B GV X-65B GV Drywell Interior GV X-26 GV X-59A(I
                                                                                                                                    . .. .i
: UNIT,  
                                                                                                                                            .p......
- 1 2 thRIO
:IN=       low :                                 .12RIO...
:IN=
limvit     A       ~~       :...* *,,'*:*,':U-1                  !Reports i 4i&#xfd;&#xfd;      +6&#xfd;&#xfd;      " 1" I4Q          io*,b,.,,..,*.,.
low :
I.                       Iaiii"6i6&#xfd;  ....................
limvit A  
I - --
~~
1n~          -r-r                      -1aI..-
756' 756' 756' 753' 763' 767' 779' 767' 779' 767' 779' 775' 768' 767' 779' 772' 2930 2970 3010 00-2 0&deg; to 900 900 to 1800 1800 to 2700 228o 2280 270' to 3600 780 65 65 65 65 65 66 67 68 68 68 69 69 69, -
NDE-VT X-81A            GV  756'    2930                                                        012        345566 65          1                    1                                  003 Rev 1 1                                          N D E--VT X-82A            GV  756'    2970                                                        012      345566 65          1                    1                                  003 Rev 1 1                                            ND E -VT X-84A            GV  756'    3010                                                        012      345566 65          1                    1                                  003 Rev 1 1                                            N-qD-E-VT X-9A              GV  753'                                                                012      345566 65        1                                                        003 Rev I 1                                          ND-E-VT X-16A            GV  763'                                                                012      345566 00-2        65        1                                                        003 Rev I 767'      0&deg; to 779'                                                                                      N-D-E-VT Drywell Interior GV                                                                      013 900      66                                                        345566    003 Rev 1 767' 779'    900 to                                                                            N-D-E-VT Drywell Interior GV            1800      67          1                                  013      345566    003 Rev 1 767'                                                    1 779'  1800 to                                                                                =NDE-VT Drywell Interior  GV                      68        1 2700                                        1            013      345566    003 Rev 1 NDE-VT X-59B            GV  775'                68 228o                                                        013      345566    003 Rev 1 NDE-VT X-65B            GV  768'                68 2280                                                        013      345566    003 Rev 1 767' Drywell Interior            270' to                                                                          NDE-VT GV  779'    3600      69                                1            013      345566  003 Rev 1 1
G:\\ISI\\IWL\\outage U1-12 sched.xls Page 26 of 34 1"
X-26              GV                                                                                          NDE-VT 772'    780        69                                            L013 345566 X-59A(I                                                                                                        N-DE-V&#xfd;T 69, -                                          013    L345566    1003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls Page 26 of 34
1 1
1 1
1 1
1 1
..i
.p......
1n~
1 1
1 1
1 1
1 1
1 1
I.
012 012 012 012 012 013 013 013 013 013 013 L013 013
.12RIO...
Reports 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 L345566 NDE-VT 003 Rev 1 N D E--VT 003 Rev 1 N D E  
-VT 003 Rev 1 N-qD-E-VT 003 Rev I ND-E-VT 003 Rev I N-D-E-VT 003 Rev 1 N-D-E-VT 003 Rev 1  
=NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N DE-VT 003 Rev 1 NDE-VT N-DE-V&#xfd;T 1003 Rev 1 io*,b,.,,..,*.,.
-r I..- - - -
-r
-1Ia....................
I i
4i&#xfd;&#xfd; aiii"6i6&#xfd; 4Q
+6&#xfd;&#xfd;
:...* *,,'*:*,':I U-1


I                                                      UNIT . 1 2 th RIO 4,
UNIT.
I                                                                                                        I X. XI~       ...S
1 2 th RIO I
                                                  ...                                    IgR........1u NDE-VT X-65A                       GV     768'     3050       69     1 1     1   013 345566 003 Rev 1 779'--   0&deg;to NDE-VT Drywell Interior           GV     791'     900       70     1 1     1   014 345566 003 Rev 1 779'-     0 9 ' to                                       NDE-VT Drywell Interior           GV     791'     1800       71     1 1     1   014 345566 003 Rev 1 779'-   1800 to                                       NDE-VT Drywell Interior           GV     791'     2700       72     1 1     1   014 345566 003 Rev 1 779'-   270&deg; to                                       NDE-VT Drywell Interior           GV     791'     3600       73     1 1     1   014 345566 003 Rev 1 D791-     900       74     1 11to1 150NDE-VT Drywell Interior           GV     794'     900       74     1 1     1   015 345566 003 Rev 1 791'-   900 to                                       NDE73T Drywell Interior           GV     794'   1800       75     1 1     1   015 345566 791'-                                                 003 Rev 1 1800 to                                       NDE-VT Drywell Interior           GV     794'     2700       76     1 1     1   015 345566 003 Rev 1 791'-   270' to                                       NDE-VT Drywell Interior           GV     794'     360&deg;       77     1 1     1   015 345566 003 Rev 1 Examination Category: E-A, Containment Surfaces E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas G:\ISI\IWL\outage U1-12 sched.xls                                    Page 27 of 34
G:\\ISI\\IWL\\outage U1-12 sched.xls I
4, X. XI~  
...S IgR........1u NDE-VT X-65A GV 768' 3050 69 1
1 1
013 345566 003 Rev 1 779'--
0&deg;to NDE-VT Drywell Interior GV 791' 900 70 1
1 1
014 345566 003 Rev 1 779'-
90' to NDE-VT Drywell Interior GV 791' 1800 71 1
1 1
014 345566 003 Rev 1 779'-
1800 to NDE-VT Drywell Interior GV 791' 2700 72 1
1 1
014 345566 003 Rev 1 779'-
270&deg; to NDE-VT Drywell Interior GV 791' 3600 73 1
1 1
014 345566 003 Rev 1 D791-900 74 1
11to1 150NDE-VT Drywell Interior GV 794' 900 74 1
1 1
015 345566 003 Rev 1 791'- 900 to NDE73T Drywell Interior GV 794' 1800 75 1
1 1
015 345566 003 Rev 1 791'-
1800 to NDE-VT Drywell Interior GV 794' 2700 76 1
1 1
015 345566 003 Rev 1 791'-
270' to NDE-VT Drywell Interior GV 794' 360&deg; 77 1
1 1
015 345566 003 Rev 1 Examination Category: E-A, Containment Surfaces E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas I
Page 27 of 34


I)
I)
UNIT'i -        2thRIO II                      I          I            F I
Note: GV Examinations are not required below the water line (672')
Note: GV Examinations are not required below the water line (672')
Suppression Chamber                   0&deg; to                                     ND -VT Interior Floor       VT-3 648'       900             1   1   1 UcC    345325  008 Rev 0 Suppression Chamber                 90&deg; to ND -VT Interior Floor       VT-3 648'     1800             1   1   1 Ucc    345325  008 Rev 0 Suppression Chamber                 180&deg; to Interior Floor                                                                   NDE-VT VT-3 648'     2700             1   1   1 Ucc    345325 008 Rev  0 Suppression Chamber                 270&deg; to N DE-VT Interior Floor       VT-3 648'     3600             1   1   1 Ucc    345325 008 Rev  0 Suppression Chamber         648'-     0Dto                                      NDE-VT Interior             VT-3 672'       900     104       1   1   Ucc    345325  008 Rev 0 NDE-VT X-206B               VT-3 659'     620       104     1   1     UcC    345325 008 Rev  0 NDE-VT X-234B               VT-3 666'     700       104     1   1     Ucc    345325 008 Rev  0 X-235B                                                                           NDE-VT VT-3 653'     440       104     1   1   1 Ucc    345325 008 Rev  0 N DE-VT X-236                 VT-3 659'     490       104     1   1   1 UcC    345325 008 Rev  0 Suppression Chamber         648-     90&deg; to Interior                                                                           D-V VT-3 672'     1800     105       1   1   Ucc    345325 008 Rev 0 X-203B                                                                         NOEV-VT-3 659'     1610     105     1   1   1 Ucc    345325 008 Rev 0 NDE-VT X-203D               VT-3 659'     1390     105     1   1   1 Ucc    345325 008 Rev 0 ND-VT-X-209                 VT-3 659'     1010     105     1   1  1 UCC  [3453275.008 Rev 0 I        1(
Suppression Chamber 0&deg; to Interior Floor VT-3 648' 900 1
Ucc    345325 008 Rev 0 G:\ISI\IWL\outage U1-12 sched.xls                           Page 28 of 34
1 1
Suppression Chamber 90&deg; to Interior Floor VT-3 648' 1800 1
1 1
Suppression Chamber 180&deg; to Interior Floor VT-3 648' 2700 1
1 1
Suppression Chamber 270&deg; to Interior Floor VT-3 648' 3600 1
1 1
Suppression Chamber 648'-
0D to Interior VT-3 672' 900 104 1
1 X-206B VT-3 659' 620 104 1
1 X-234B VT-3 666' 700 104 1
1 X-235B VT-3 653' 440 104 1
1 1
X-236 VT-3 659' 490 104 1
1 1
Suppression Chamber 648-90&deg; to Interior VT-3 672' 1800 105 1
1 X-203B VT-3 659' 1610 105 1
1 1
X-203D VT-3 659' 1390 105 1
1 1
X-209 VT-3 659' 1010 105 1
1 1
G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT'i -
2thRIO II I
I F
UcC Ucc Ucc Ucc Ucc UcC Ucc Ucc UcC Ucc Ucc Ucc UCC Ucc 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325
[3453275 345325 008 Rev 0 ND -VT 008 Rev 0 ND -VT 008 Rev 0 NDE-VT 008 Rev 0 N DE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 N DE-VT 008 Rev 0 D-V 008 Rev 0 NOEV-008 Rev 0 NDE-VT 008 Rev 0 ND-VT-
.008 Rev 0 Page 28 of 34 1(
I I


I)
I)
UNIT 1 - 12           RIO I
G:\\ISl\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO X-214 VT-3 659' 129&deg; 105 1
X-214               VT-3 659'     129&deg;       105     1 1 1 UCC 345325 008 RevO0 Suppression Chamber     648-   1     to                               NDE-VT Interior           VT-3 672'     2700       106     1 1 1 UCC 345325 008 Rev 0 ND E-VT X-203A               VT-3 659'     2210&deg;     106     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-203C             VT-3 659'     1990       106     1 1 1 UCC 345325 008 Rev 0 Suppression Chamber     648'-   270&deg; to                                 NDE-VT Interior           VT-3 672'     3600       107     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-206A               VT-3 659'   2970       107     1 1 1 UCC 345325 008 Rev 0 N D E-VT X-219B               VT-3 666'   2860       107     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-222               VT-3 657'     3Q07       107     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-232B               VT-3 653'   2800       107     1 1 1 UCC 345325 008 Rev 0 X-237               VT-3 659'     311 &deg;     107     1 1 1 UCC 345325 008 RevO0 IX-243               VT-3 646'   2760       107     1 1 1 UCC 345325 008 Rev 0 Suppression Chamber       672' -   00 to:NEV Interior             GV   683'     9Q0       108     1 1 1 UCC 345325 008 Rev 0 INDE-VT
1 1
                  !X-208B               GV   673'     490       108     1 1 1 UCC 345325 008 Rev 0
UCC 345325 008 RevO0 Suppression Chamber 648-1 to NDE-VT Interior VT-3 672' 2700 106 1
                                                                                            *NDE-VT X-212                 GV   673'     560       108     1 1 1 UCC 345325 008 Rev 0 G:\ISl\IWL\outage U1-12 sched.xls                          Page 29 of 34
1 1
UCC 345325 008 Rev 0 ND E-VT X-203A VT-3 659' 2210&deg; 106 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-203C VT-3 659' 1990 106 1
1 1
UCC 345325 008 Rev 0 Suppression Chamber 648'- 270&deg; to NDE-VT Interior VT-3 672' 3600 107 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-206A VT-3 659' 2970 107 1
1 1
UCC 345325 008 Rev 0 N D E-VT X-219B VT-3 666' 2860 107 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-222 VT-3 657' 3Q07 107 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-232B VT-3 653' 2800 107 1
1 1
UCC 345325 008 Rev 0 X-237 VT-3 659' 311 &deg; 107 1
1 1
UCC 345325 008 RevO0 IX-243 VT-3 646' 2760 107 1
1 1
UCC 345325 008 Rev 0 Suppression Chamber 672' -
00 to:NEV Interior GV 683' 9Q0 108 1
1 1
UCC 345325 008 Rev 0 INDE-VT  
!X-208B GV 673' 490 108 1
1 1
UCC 345325 008 Rev 0  
*NDE-VT X-212 GV 673' 560 108 1
1 1
UCC 345325 008 Rev 0 I
Page 29 of 34


I)
I)
UNIT '. 12t RIO S............
S............
ii'': .........
ii'':.............
i i~
i i~ i ii............
                          ....i ii............ *:  : iii       *iii~~~iiiiiiiii X.      iii ii ii     i !     iiiii*:..,:
X.
:,.,:::...*:...:::. iii~               iii il NDE-VT X-220B                     GV     674'       440             108     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-224                       GV     677'       770             108     1 1           1                 UCC 345325   008 Rev 0 NDE-VT iX-229B                     GV     673'       630             108     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-234A                     GV     674'       710             108     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-238B                     GV     674'       52&deg;             108     1 1           1                 UCC 345325   008 Rev 0 Suppression Chamber             672'-     900 to                                                                   NDE-VT Interior                   GV       683'     1800             109     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-210                     GV     674'     1090             109     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-211                       GV     677'       940             109     1 1           1                 UCC 345325   008 RevO0 NDE-VT X-213                     GV     673'       990           109     1 1           1                 UCC 345325   008 RevO0 NDE-VT X-215                     GV     674'       1290           109     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-216                     GV       677'     1240           109     1 1           1                 UCC 345325   008 Rev 0 NDE-VT X-217                     GV       673'     1220           109     1 1           1                 UCC 345325 1008RevO0 NDE-VT X-225                     GV       677'     1390           109     1 1           1                   UCC 345325   008 Rev 0 NDE-VT X-226B                     GV       673'     153&deg;           109     1 1           1                 UCC 345325   008 Rev 0 G:\ISI\IWL\outage U1-12 sched.xls                                       Page 30 of 34
: iii  
*iii~~~iiiiiiiii iii ii ii i !
iiiii*:..,:
:,.,:::...*:...:::. iii~
iii il NDE-VT X-220B GV 674' 440 108 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-224 GV 677' 770 108 1
1 1
UCC 345325 008 Rev 0 NDE-VT iX-229B GV 673' 630 108 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-234A GV 674' 710 108 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-238B GV 674' 52&deg; 108 1
1 1
UCC 345325 008 Rev 0 Suppression Chamber 672'-
900 to NDE-VT Interior GV 683' 1800 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-210 GV 674' 1090 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-211 GV 677' 940 109 1
1 1
UCC 345325 008 RevO0 NDE-VT X-213 GV 673' 990 109 1
1 1
UCC 345325 008 RevO0 NDE-VT X-215 GV 674' 1290 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-216 GV 677' 1240 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-217 GV 673' 1220 109 1
1 1
UCC 345325 1008RevO0 NDE-VT X-225 GV 677' 1390 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-226B GV 673' 153&deg; 109 1
1 1
UCC 345325 008 Rev 0 G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT '. 12t RIO Page 30 of 34


I4                                                 I   th UNITi-12           RIO I
I4 I
NDE-VT X-228D             GV 673'   1020     109     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-244               GV 677'   112&deg;     109     1 1 1 UCC 345325 008 RevO0 NDE-VT X-245               GV 673'   120&deg;     109     1 1 1 UCC 345325 008 RevO0 NDE-VT X-246B             GV 674'   167&deg;     109     1 1 1 UCC 345325 008 Rev 0 Suppression Chamber   672'- 1800&deg;-                               NDE-VT Interior           GV 683'   2700     110     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-246A             GV 674'   1940     110     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-226A             GV 673'   2060     110     1 1 1 UCC 345325 008 Rev 0 ND E-VT X-228C             GV 673'   2350     110     1 1 1 UCC 345325 008 Rev 0 Suppression Chamber   672'- 270&deg;-                                 ND E-VTI Interior           GV 683'   3600     111     1 1 1 UCC 345325 008 Rev 0 N DE-VT X-231A             GV 673'   276&deg;     111     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-231B             GV 673'   2820     111     1 1 1 UCC 345325 008 RevO0 N DE-VT X-230A             GV 673'   2910&deg;     111     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-229A             GV 673'   2940     111     1 1 1 UCC 345325 008 Rev 0 NDE-VT X-208A             CV 673'   3110&deg;     111     1 1 1 UCC 345325 008 RevO0 NDE-VT X-238A             GV 674'   3370     111     1 1 1 UCC 345325 008 Rev 0 G:\ISI\IWL\outage U1-12 sched.xls                    Page 31 of 34
G:\\ISI\\IWL\\outage U1-12 sched.xls I
th UNITi-12 RIO NDE-VT X-228D GV 673' 1020 109 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-244 GV 677' 112&deg; 109 1
1 1
UCC 345325 008 RevO0 NDE-VT X-245 GV 673' 120&deg; 109 1
1 1
UCC 345325 008 RevO0 NDE-VT X-246B GV 674' 167&deg; 109 1
1 1
UCC 345325 008 Rev 0 Suppression Chamber 672'-
1800&deg;-
NDE-VT Interior GV 683' 2700 110 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-246A GV 674' 1940 110 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-226A GV 673' 2060 110 1
1 1
UCC 345325 008 Rev 0 ND E-VT X-228C GV 673' 2350 110 1
1 1
UCC 345325 008 Rev 0 Suppression Chamber 672'-
270&deg;-
ND E-VTI Interior GV 683' 3600 111 1
1 1
UCC 345325 008 Rev 0 N DE-VT X-231A GV 673' 276&deg; 111 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-231B GV 673' 2820 111 1
1 1
UCC 345325 008 RevO0 N DE-VT X-230A GV 673' 2910&deg; 111 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-229A GV 673' 2940 111 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-208A CV 673' 3110&deg; 111 1
1 1
UCC 345325 008 RevO0 NDE-VT X-238A GV 674' 3370 111 1
1 1
UCC 345325 008 Rev 0 Page 31 of 34


UNIT.           2thRIO I
UNIT.
                                !ii!!i~i~ii~iiiiiii'                                       ................
2thRIO I
                                                                                                        ..y.............
G:\\ISl\\IWL\\outage U1-12 sched.xls
                                                                                                                      .....::            iii! iiiiiiiiiiii NDE-VT X-220A                           GV 674'     326&deg;       111     1 1       1             UCC           345325 008 Rev 0 NDE-VT X-219A                           GV 674'     2860       111     1 1       1             UCC           345325 008 RevO0 Examination Category: E-A, Containment Surfaces EIA10iContainment Vessel Pressure Retaining Boundary El .20 Vent System Accessible Surface Areas Suppression Chamber Interior 660'-                                                                         NDE-VT VT-3 672'   0&deg;-900   020/021A   1 1       1             UCC           345325 008 Rev 0 900-                                                                 NDE-VT 1800   020/021A   1 1         1           UCC           345325 008 Rev0 1800-                                                                 NDE-VT 2700     020/021A   1 1         1             UCC           345325 008 Rev 0 2700-                                                                 NDE-VT 3600     020/021A   1   1       1             UCC           345325   008 Rev 0 672'-                                                                         NIDE-VT VT-3   683'   00-900   020/021A   1   1       1             UCC           345325   008 Rev 0 900                                                                 NDE-VT 1800   020/021A   1   1       1             UCC           345325 008 Rev 0 1800-                                                                 NDE-VT 1 2700     020/021A   1 1       1             UCC           345325 008 Rev 0 2700-                                                                 NDE-VT 3600   020/021A   1 1       1             UCC           345325 008 Rev 0 G:\ISl\IWL\outage U1-12 sched.xls                                      Page 32 of 34
!ii!!i~i~ii~iiiiiii'  
.. y.............
iii!
iiiiiiiiiiii NDE-VT X-220A GV 674' 326&deg; 111 1
1 1
UCC 345325 008 Rev 0 NDE-VT X-219A GV 674' 2860 111 1
1 1
UCC 345325 008 RevO0 Examination Category: E-A, Containment Surfaces EIA10iContainment Vessel Pressure Retaining Boundary El.20 Vent System Accessible Surface Areas Suppression Chamber Interior 660'-
NDE-VT VT-3 672' 0&deg;-900 020/021A 1
1 1
UCC 345325 008 Rev 0 900-NDE-VT 1800 020/021A 1
1 1
UCC 345325 008 Rev0 1800-NDE-VT 2700 020/021A 1
1 1
UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1
1 1
UCC 345325 008 Rev 0 672'-
NIDE-VT VT-3 683' 00-900 020/021A 1
1 1
UCC 345325 008 Rev 0 900 NDE-VT 1800 020/021A 1
1 1
UCC 345325 008 Rev 0 1800-NDE-VT 1 2700 020/021A 1
1 1
UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1
1 1
UCC 345325 008 Rev 0 Page 32 of 34


I                                                   UNIT I     - f 2 th RIO I
I I
683'-                                                   NDE-VT VT-3     700' 0o-900   020/021A       1 1     1 UCC 345325 008 Rev 0 900-                                           NDE-VT 1800   020/021A       1 1     1 UCC 345325 008 RevO0 1800-                                           NDE-VT 2700   020/021A       1 1     1 UCC 345325 008 Rev 0 2700-                                           NDE-VT 3600   020/021A       1 1       1 UCC 345325 008 RevO0 Examination Category: E-G, Pressure Retaining Bolting E8.20 Bolted Connections____________
G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT I - f 2 th RIO 683'-
NDE-VT Personnel Hatch (X-2) VT-1     724'     1340     003A-L       1   1         016 345572 001 Rev 1 NDE-VT Equipment Hatch(X-1       VT-1   724'   3150     004-A-B       1   1         022 345572 001 Rev 1 Examination Category: L-A, Containment Surfaces L1.i10 Concrete Surfaces                                           ____ ___ ______
NDE-VT VT-3 700' 0o-900 020/021A 1
L1i-1. Accessible Concrete Surfaces and Coated Areas Drywell - Extekr G:\ISI\IWL\outage U1-12 sched.xls                                Page 33 of 34
1 1
UCC 345325 008 Rev 0 900-NDE-VT 1800 020/021A 1
1 1
UCC 345325 008 RevO0 1800-NDE-VT 2700 020/021A 1
1 1
UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1
1 1
UCC 345325 008 RevO0 Examination Category: E-G, Pressure Retaining Bolting E8.20 Bolted Connections____________
NDE-VT Personnel Hatch (X-2) VT-1 724' 1340 003A-L 1
1 016 345572 001 Rev 1 NDE-VT Equipment Hatch(X-1 VT-1 724' 3150 004-A-B 1
1 022 345572 001 Rev 1 Examination Category: L-A, Containment Surfaces L1.i10 Concrete Surfaces L1i-1. Accessible Concrete Surfaces and Coated Areas Drywell - Extekr Page 33 of 34


UNITi-12 P    th RIO
)
                                                                                                            )
P th UNITi-12 RIO I
I 704' -NDE-VT Concrete Surface     VT-30 719'   00   90&deg;     30     1 1   1 017 345565 003 Rev 1 90o&deg;                                         NDE-VT 180&deg;         31     1 1   1 017 345565 003 Revl1 180&deg; -                                     NDE-VT 2700           32     1 1   1 017 345565 003 Rev 1
G:\\ISI\\IWL\\outage U1-12 sched.xls 704' -NDE-VT Concrete Surface VT-30 719' 00 90&deg; 30 1
___              270&deg; -         35      1  1TOO3Rv            NDE.-VT 3600           33     1 1   1 017 345565 003 Rev 1 1
1 1
719' -                                             NDE-VT VT-3C 749'   Q0- 90&deg;     34     1 1   1 018 345565 003 Rev 1 90&deg; -                                       NDE-VT
017 345565 003 Rev 1 90o&deg; N DE-VT 180&deg; 31 1
__18O0&deg;                                   3       1 1   1 018 34556503Re1 1807-                                       NDE-VT 2709           36     1 1   1 018 345565 003 Revl1 2700   -                                    NDE-VT 3600           37     1 1   1 018 345565 003 Revl1 749'-                                               NDE-VT VT-3C 779g   20 - 90&deg;     38     1 1   1 019 345565 003 Rev 1 900"                                       NDE-VT 1800         39     1 1   1 019 345565 003 Revl1 1800 -NDE-VT 270         340      1 1   1 019 345565 003 Rev 1 2700-                                       NDE-VT 3600         41     1 1   1 019 345565 003 Rev 1 G:\ISI\IWL\outage U1-12 sched.xls                          Page 34 of 34
1 1
017 345565 003 Revl1 180&deg; -
NDE-VT 2700 32 1
1 1
017 345565 003 Rev 1 270&deg; -
NDE.-VT 3600 33 1
1 1
017 345565 003 Rev 1 1
719' -
NDE-VT VT-3C 749' Q0- 90&deg; 34 1
1 1
018 345565 003 Rev 1 90&deg; -
NDE-VT
__18O0&deg; 3
1 1
1 018 34556503Re1 35 1
1TOO3Rv 1807 -
NDE-VT 2709 36 1
1 1
018 345565 003 Revl1 2700 NDE-VT 3600 37 1
1 1
018 345565 003 Revl1 749'-
NDE-VT VT-3C 779g 20 - 90&deg; 38 1
1 1
019 345565 003 Rev 1 900" NDE-VT 1800 39 1
1 1
019 345565 003 Revl1 1800 -NDE-VT 270 3 40 1
1 1
019 345565 003 Rev 1 2700-NDE-VT 3600 41 1
1 1
019 345565 003 Rev 1 Page 34 of 34


APPENDIX G CORRECTIONS
APPENDIX G CORRECTIONS


Page 1 of 1 No corrections to previous ISI Outage Summary Reports were made.}}
Page 1 of 1 No corrections to previous ISI Outage Summary Reports were made.}}

Latest revision as of 16:28, 16 January 2025

Twelfth Refueling & Inspection Outage ISI Summary Report, Appendix D.2, Modification Group NIS-2 Forms
ML022120396
Person / Time
Site: Susquehanna 
Issue date: 07/19/2002
From: Shriver B
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-5503
Download: ML022120396 (190)


Text

APPENDIX D.2 MODIFICATION GROUP NIS-2 FORMS

WORK ABSTRACT The Site Modifications Group is responsible for preparing Work Orders (work packages) for fabrication and installation of design changes in accordance with ASME Section XI and the National Board Inspection Code. This work is documented on NIS-2 Forms, or on R-1 Forms, which are submitted herewith.

MODIFICATION INSTALLATION GROUP Design Change Packages for ASME Section Xl ( Class 1, 2 and 3), and the National Board Inspection Code, installed in Unit 1 since the completion of the Eleventh Refueling Outage through completion of theTwelfth Refueling Outage are summarized below:

DESIGN CHANGE SYSTEM / CLASS PACKAGE DESCRIPTION NUMBER 97-9100D, F and G 024A III Replaced Fuel Oil Day Tank level transmitters 179458 145AI Permanent Removal of Snubber Supports SPDBA1 03 H2000 and SPDBA1 07-H2000 310917

  • 147 Welded repairs to nozzle base metal damage on replacement Feedwater Heaters 94-3023B and C 149A III Replacement and Repair of RHR Motor Oil Coolers 179459 149C I Permanent Removal of Snubber Support SPDCA1 17 H14 352940 151A II Relocation of Instrument Rack 1 C057 318280 153A II Replace SBLC Pump Discharge Flange and Re-rate SBLC Pump and Discharge Piping, 224005 161B III Replace RWCU Pump Proximity Probes with Pipe Plugs.

316329, 316330, 162AI Modified inboard MSIVs, HV141F022A, B, C, and D to 316331,316332 improve seating characteristics.

179460 162A II Permanent Removal of Snubber Supports SPDCB112 H2003 and SPDCB1 12-H2014 179459 164A I Permanent Removal of Snubber Support SPDCA120 H2006 179459 164A II Permanent Removal of Snubber Support SPDCB112 H2094 179459 164D II Permanent removal of snubber support SPDCB106 391402 H2002 and Replaced piping SPDCB106-6, 391467 SPDCB106-8, and SPDCB121-4, do to socket weld UT Exam failures.

316333,316334, 316335,316336 183A I Modified outboard MSIVs, HV1 41 F028A, B, C, and D to improve seating characteristics.

  • National Board Inspection Code repair of an ASME Section VIII vessel in a non-nuclear system.

024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Address PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet Unit 5-JUNE-2002 1

of ONE SEE PAGE 4 AND 5 Repair OrganizatK)n P.O. No., Job No.. etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date

4. Identification of System DIESEL GENERATOR and AUXILIARY SYSTEM
5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, Code Case
7. Description of Work SEE PAGE 4 AND 5
8. Tests Conducted:

Hydrostatic F Pne Other E Pressure

=umatic FE N/A Nominal Operating Pressure psi Test Temp.

N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant N/A 024A-III ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

(1) SMALL PIPE BECHTEL N/A N/A SPHBC94-1 1982 REPLACED YES ASSEMBLY (2)

SMALL PIPE PPL N/A N/A SPHBC94-1 2000 REPLACEMENT NO ASSEMBLY (3) 1 PLUG VALVE TUFLINE 89267L-3 N/A 034072B 1979 REPLACED YES XOMOX (4) 1" PLUG VALVE TUFLINE 89267L-5 N/A 034073B 1979 REPLACED YES XOMOX (5) 1" BALLVALVE BNL A981004-1-2 N/A 034073B 1999 REPLACEMENT YES INDUSTRIES (6) SMALL PIPE BECHTEL N/A N/A SPHBC94-1982 REPLACED NO SUPPORT H2000 I-D

°F (12/82)

FORM NIS-2 (Back)

9. Remarks CODE DATA REPORT(S) ATTACHED Applicable Manufacturer's Data Renors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date 2/-

20 e Owner(& Owner's ee, Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period

/10

/,-

9-to

!T-A-0/

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1L~4~i, 2??'Commissions A113 7 980 A. N. 1; 9?- AU P4 ~Z-Cý0J Inspector's *Vnature National Board, State, Province, and Endorsements Date

,J.iN ZL I 2002 r'h

024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Date Sheet Add Unit SEE PAGE 4 AND 5

3. Work Performed by 769 Salem Address PPL Sus Blvd, Berwic Address
4. Indentification of System Adcre Repair OrganIzation P.O. No., Job No., etc squehanna, LLC Type Code Symbol Stamp None ck, PA 18603 Authorization No.

N/A Expiration Date N/A DIESEL GENERATOR and AUXILIARY SYSTEM 024A-III

5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda,
1. Owner
2. Plant 5-JUNE-2002 2

of 2

ONE Code Case ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

(7)

SMALL PIPE BECHTEL N/A N/A SPHBC94-1982 REPLACED NO SUPPORT H2001 (8)

SMALL PIPE BECHTEL N/A N/A SPHBC96-1 1982 REPLACED YES ASSEMBLY (9)

SMALL PIPE PPL N/A N/A SPHBC96-1 2000 REPLACEMENT NO ASSEMBLY (10) 1" PLUG VALVE TUFLINE 89267L-1 N/A 034072D 1979 REPLACED YES XOMOX (11) 1"PLUG VALVE TUFLINE 89267L-7 N/A 034073D 1979 REPLACED YES XOMOX (12) 1" BALL VALVE BNL A981004-1-4 N/A 034073D 1999 REPLACEMENT YES INDUSTRIES (13)

SMALL PIPE BECHTEL N/A N/A SPHBC96-1982 REPLACED NO SUPPORT H2000 (14)

SMALL PIPE BECHTEL N/A N/A SPHBC96-1982 REPLACED NO SUPPORT H2001 (15)

LEVEL MORRISON SA-613 N/A SA-613 1985 REPLACED YES TRANSMITTER KNUDSEN PIPE ASSEMBLY

024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant PPL Susquehanna, LLC Name 769 Salem BIvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Sus 769 Salem Blvd, Berwic Address
4. Indentification of System Date Sheet Add Unit 5-JUNE-2002 3

of 3

ONE SEE PAGE 4 AND 5 Addre Repair Organization P.O. No., Job No., etc.

squehanna, LLC Type Code Symbol Stamp None

k, PA 18603 Authorization No.

N/A Expiration Date N/A DIESEL GENERATOR and AUXILIARY SYSTEM 024A-III

5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, Code Case ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or (16) BLIND FLANGE PPL N/A N/A SA-613 2000 REPLACEMENT NO (17)

SMALL PIPE PPL N/A N/A SPHBC3304-14 2000 REPLACEMENT NO ASSEMBLY (18) 1 " BALL VALVE BNL A990801-2-2 N/A 034829E 2000 REPLACEMENT YES INDUSTRIES (19)

PIPE PLUG APPLIED NC-4164-05 2742 OT-528E 1984 REPLACED NO NOZZLE H ENGINEERING

024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet 5-JUNE-2002 4

of Add Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Unit Addre Address PPL Susquehanna, LLC ONE SEE PAGE 4 AND 5 Repair Organization P.O. No, Job No., etc Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address
4. Indentification of System Authorization No.

Expiration Date DIESEL GENERATOR and AUXILIARY SYSTEM

5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

ITEM WORK ORDER I JOB NUMBER CONSTRUCTION CODE DESCRIPTION OF WORK 1 -2 PCWO 99998 / DCP 97-9100D ASME SECTION III REPLACEMENT OF BRAVO DIESEL DAY CRF G99-023-010 1971 EDITION, WINTER 72 ADD.

TANK LEVEL TRANSMITTER PIPING 3 -4 PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010 1977 EDITION, SUMMER 78 ADD.

TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE 5

PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-010 1974 EDITION, NO ADDENDA.

TRANSMITTER REPLACEMENT ISOLATION VALVE 6 -7 PCWO 99998 / DCP 97-9100D ASME SECTION III BRAVO DIESEL DAY TANK LEVEL CRF G99-023-015 1971 EDITION, WINTER 72 ADD.

TRANSMITTER DELETED PIPE SUPPORTS 8-9 PCWO 100221 / DCP 97-9100F ASME SECTION III REPLACEMENT OF DELTA DIESEL DAY CRF G99-024-012 1971 EDITION, WINTER 72 ADD.

TANK LEVEL TRANSMITTER PIPING 10- 11 PCWO 100221 / DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-012 1977 EDITION, SUMMER 78 ADD.

TRANSMITTER ISOLATION VALVE REPLACED AND DELETED DRAIN VALVE 1 Owner

2. Plant 4

N/A N/A 024A-III

Addenda, Code Case

024A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Date Sheet Add Susquehanna Steam Electric Station Name Unit 5-JUNE-2002 5

of 5

ONE 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Addre PP sare us PPL Susquehanna, LLC SEE PAGE 4 AND 5 Repair Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address

4. Indentification of System Authorization No.

Expiration Date rltFS'FI (*FNFRATOR and AUXILIARY SYS N/A N/A STEM 024A-1II

5. (a) Applicable Construction Code SEE PAGE 4 & 5 19
Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
Addenda, Code Case
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No) 12 PCWO 100221 / DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-012 1974 EDITION, NO ADDENDA.

TRANSMITTER REPLACEMENT ISOLATION VALVE 13-14 PCWO 100221 1 DCP 97-9100F ASME SECTION III DELTA DIESEL DAY TANK LEVEL CRF G99-024-017 1971 EDITION, WINTER 72 ADD.

TRANSMITTER DELETED PIPE SUPPORTS 15-16 PCWO 100222 / DCP 97-9100G ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1980 EDITION, SUMMER 81 ADD TRANSMITTER REPLACEMERNT OF CODE CASE N-316.

EXISTING WITH BLIND FLANGE 17 PCWO 100222 / DCP 97-9100G ASME SECTION III ECHO DIESEL DAY TANK NEW LEVEL CRF G99-023-013 1971 EDITION, WINTER 72 ADD TRANSMITTER SMALL BORE PIPE INSTALLATION 18 PCWO 100222 / DCP 97-910OG ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1974 EDITION, NO ADDENDA TRANSMITTER NEW ISOLATION VALVE 19 PCWO 100222/ DCP 97-91 OOG ASME SECTION III ECHO DIESEL DAY TANK LEVEL CRF G99-023-013 1980 EDITION, SUMMER 81 ADD TRANSMITTER RELOCATION TO TANK SPARE NOZZLE LOCATION H.

1 Owner

2. Plant DIESEL GENERATOR and AUXILIARY SY

For Information Only FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section Ill. Division 1 2

Pg. l of_

1. ManufactureSd CI certified by NL INDUSTRIES, INC.,

30 INDUkTRIAL PARK ROAD,

VERNON, CT, 06066 (rwre ". edd

.*I.

o N Cetflslft

. 4016w)

PEN*(SYLVANIA POWER & LIGHT CO, TwO NORTH NINTH ST,ALLENTOWN,PA 18101

2. Manufactured for imam* w4od add.e.

of Prchaseed SUSQUEHANNA, 5 MI NE OF BERWICK, PA, 18603

3.

Locationl of inatbllatgofl (nrwne end addreIai/

VALVE HBV-A2-06-00 58 0

4. Model No., Series No., or T"ype Drawig Rev.

CRN

5. AS&

Code. Seciion IN, Division 1:

-1974

/

3

/

ledoDlon) laddenda d.tea Icl*a/

(Code Came no.1 VALVE 3/4" 3/4

6. Pump or vhs*v Nominal inlet in--

O utlet lip)

SA-105 SA-105 SA-479 Ty316 SA-193 GrB7/SA-194 Gr2H "7.

Material:

Body

-onnt Disk Bolting (a) 1b)

Conl.

Nt'l Holder's Board Serial No.

/

No.

A981004-I- (1THRU4) 1c)

Do*y No.

N62 serial No.

O f*)

Disk Serial No.

/

L95/

-S*ppjsslal inOflt,,*don in fo oiu e6lM. l O

an a.m drowt, gs may ba, used pr'ovded1) @! z Is N18 0

1K. ill 21 hf Mmqinn heams I t1rough 4 on twh Del. Aeport is ircudad on eoch

~hi, 131 eat doth is rwjvnbed e"d the nmamrbr of,eOft is rwrded 01 the too f Unla tfom.

(121")

Thi fog..

E000371 may be 0 ta-ism dw COnsw Dept.. AhW. 22 Law OuSDr*. ba2300, FoaId, NJ 07007-2300.

,or Information Only FORM NPV-1 (B ack -

P g.2of 2-Z- )

.f.

I ~

Certificats Holder's Sedial No.

ANSI 600#

S. Design conditlons psi IF or vshve presaure las1 It) 1presstuereltw~

9. Cold workig pressure 10 palatIOOF

/

2225 1630

10. H*vdroetstic teat psi.

Disk dMiereniai test pressure

11. Remarrks:

CEwRTIFCATION OF DESIGN J.G.

SHELLENBERGER PA 19551-E Design Specification certified by P.E. State Pftg. no.

Desigy Report certified by PA. Stat.

Reg. no.

11) For manually operated valV*s Only.

CERTIFICATE OF COMPLIANCE We cegrty het the statements made in his report wre correct and that this pump or valve conforms to the rnles for constuction of the ASME Code, Section IN, Divlsion 1.

)-2882 11/10/01 h4 Certificate of Authorlzatlon No Explree Dite 06/17/99

-N BNL INDUSTRIES, INC.

Signed (N Cardfrate ai.e.)

CERTIFICATS OF INSPECT)ON

1. the unidetsigned. hokling a vaid commnssirn Issued by the National BOaOd Of 00lggV aner T*

d the State or Province of CONNECTI CUT and employed by of

BOSTON, M4AS S have Inspected the pump. or valve, descrkmd in this Date Report on 06/17/9

.nd state that to the best of my knowledge and belief, the Certificate Holder hea co*

atructed this pump, or valve, In eccotdamn1 with the ASME Code. Section 111, Diviasion 1.

Sy signing this certificate. neither the inspectot nor his employer miesi eny, warranty, expressed or Implied. coricrnilg the component described In this Data Report. Furthermore. neither the Inspector not his employer shall be liable in ars mannw tfr "ary perseeal inp.Wy or property damage or a loss of any kind arising from or cornected with ths inspection.

Data Signed Commisslons r4

/3 9cM4 l

4 eJ c7 fq-d LAuth*Oz*

WO M1 1n1coe

~fol.

Be. (irnS. endorsernerval and state or prey, end n9J

rTnf ormation Only FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Cods, Section 111, Division I p.Io

1. Manufacured an otfied

'by BNL INDUSTRIES, INC., 30 INDUSTRIAL PARK ROAD, VERNON, CT, 06066 iname end aM... of N Cart~fica Hoidmi)

PENNSYLVANIA POWER & LIGHT CO, TWO NORTH NINTH ST,ALLENTOWN,PA 18101 Z. MaWVCIUTId rnae amA aiddr of Puechaaar 3.Loatonof"WstonSUSQUEHANNA, 5 MI NE OF BERWICK, PA, 18603 Inam.r and.ddresal VALVE HBV-A2-40-00S 9

A A4. Model No-, Serie No., or Type Drowing PAY.

CR14

5. ASIAE Code.Section III, Division 1:

1974_______3 VAVEidsoanl 1 addends ate 41icisasi (Code Cowa r-.

6. Pum~p or valve VA Nominal inlet al~

1*,

is SA-1O5 SA-105 SA-479 Ty3165 SA-193 GrB7/SA-194 Gx2E

7. Maiarial:

Body-S______

onnet _________

Disk aohing as)

ID]

Cart.

Nat'l Holder's

/

Board Sedal No..

No.

A,9810_4_-

2 - (1THRU2) cc)

So"y No.

Ml 60 Seilal No.1/

Disk Solial o

Suppt~ms r W ntm mlo va i~e inm t o fn limo., sk that ",e ar dtaw kg M ay 'a imaad Pmvo da

11) ae Iao CV K 11~. Ili hI c,..udat h n ba nam I titr o og 4 on chis Dole ftaaor is ircluded on sael cheam.

131 each ehat it nunbard and thea iwbar of Omar is reor~ded at thatoP Of d"e 1100%.

1121601 ThW&

form, JE000371 Inal be 06016a fromt va Order Dapv,.ASMI, 22 Low Drive. Sos 2300, Fajrfiald N.J 07007-2300-

er Ijformation Only FOaRM NPV-1 (Back - Pg.2of 2- -)

Certifcsta Hokla's Sial No..A 9 8 1004

_(ITHRU2)

ANSI 600#

a. Oesign condilionl psi ra'F of volvo Presaroe ill
9. Col working pasae 10 psl atlOO0F 2225

/

1630

/

10. Hydrostatic test 2ps.

Disk afferantial lest prsau-163

11. Remork3:

CERTIFICATION OF DESIGN J.G. SHELLENBERGER PA 19551-E Design Specification certified by P.1. State Reg. no.

Design Repor certified by P.. State PM. no.

CERTIRCATE oF COMPUANCE We certift

" the statamenus made In this report are correct ar*d that this pump or valve conforms to the rubs for ConstnictiOn of the ASME Code. Section 11I. Dvision 1.

N-2882 11/10/01 N Certificate of Authwaortioin No.

Expires 06/17/99 BNL INDUSTRIES, INC.

6td Onto

~~~IN Cu~wtifet HPdw igw CENWICATIE OF INSPECTION 1, the undersigned. holting a valid comrngealofl Issued by the National board ofDlarndPereVoe noctSed the Siate or Province of CONNECTICUT and employed OU SBOSTON, MASS hove Insected the pump. or valve. described in this Dots AePort on 06/17/99 n

elate that to the beet of my knowledge athd belief, the Certifcte Holder has con atnictod this pump, or valve, I accordance with the ASME Code, Section 10, Div n 1.

By aignirn this certificate, neither the inspector not lie employer mikes any warranty, expreased or Implied, conceinng the compontfll deacrlbed in this Data Report. Furthermore. neilhee the inspector nor his amployer shall be liabie in env manner few any personel knpry or properts" mage ora loss of any kind arising from or connected with this inspection.

Dale Siqndz ComIuslona

?,. 4. Ad r-7-. /

4 (4 L~uthorlsed Inspectorl ihati. lsr. 1Und. endorernaestl andstate or prow. end no.1 I1) Far manually operated v1Vea only.

FORM NPV-1 CERTIFICATE HOLOERS'DATA REPORT FOR NUCLEAR PUMPS OR VALVES' As Required by the Provisions of the ASME Co",. Section 1II, DivWon 1 P.Io

1. Manufacturend Acarti~fidby 5liL INDUSTRIES, INC., 30 INDUSTRIAL PARK ROAD, VERNON, CT, 06066 (namei and addrawm of N Cariffieato Holder?

PENNSYLVANIA POWER

& LIC;H-T CO, TWO NORTH NINTH ST,ALLENTrOWN,PA 18101

2. MantrfactUund for

-mam Sn addrss ofprc1 r

SUSQUEHANNA, 5 MI FE OF BERWICK, PA, 18603

3. Location of kwuat~eion VALVE HBV-Z 10-0%Th A
4. Model No.. Serins No., of Type Drawing Pav. ______

CRN_____

5. ASME Code. Section 111 oj.iuiaon 1;-

1974/..

3 geditwnrl touddndo ""1 11:9111 (Cede Came no.1

a. Pumnp or aiv VA E

nik Inleto.

Otrdri-!,

0h.1 SA-10, 5 one SA-1{5 SA-479 Ty316,,,4 SA-293GrB7/SA-I94Gz2H /

7. Mart&"a:

Body ont_______

Disk Bow"M

18)

Carl Holder'$

Serilel No.

A.990801 (1)~

Board No.

10) body me.

N56 id) bonn~l No.

L73 (01 No.

N218 N218

  • Suppiwenwtal intoraw4.A In

.9-

& lism, smah.ee or dre Ig sao rwbe waed p6avld-d 11) *its 1* S% x 11, f2s bkfnlonitlon in heme I through~ 4 on "ta Data pepoet is, on~e each

.addea.

J) gecoh wnwt Is nwyueranie~end tha my.b, o f

~mat ie "Cacrded at Ont to of 6"e torm.

112151)Thitl lesw a(1000371 may Ia. ob~dtrw t.e crew. Do"_ ASM*. 22 Low Dri.,.. 111" 2300, F.irfaeil. NJ 07007-22M0.

n-r

or rfrnrm,-Itinn Onl';

FORM NPV-1 (Back -

Pg. 2 of 2

1 A990801 (142)

Cartlite-ste Holder's Serial No.

ANSI 600#

8. Design conditlos PSI IF or vale pressure ciass
9. Cold working pressure 10 psi at 10001 2225
10. Hydrosateic test pai. Disk dlflerntial 1630 lail DraSKKw I¶atT.ary.a; CERTWWATUO OF O~ENM D.M. GROVES PA 24926-E Designi Spectlration cartified by P.1E. State Flag. no.

Oseegn Report certified by P.

E. State Reg. no.

CENT111ICATE OF CO&OLAMI(M We ceratiy "ia the saoitteinerf made In this faplor are correct a" that this pumnp or vaive conloirri, 10 th. ue for consiruetion ofthe ASh Code, Section IIIOM~vloE'1.

N-2882 11/10/01 N Cmnjifitat at Authodriationi No Expires Daa06/01/00 Nr-BNL INDUSTRIES,

]:NC._

INl Qw#a~dstv Haldenl Signmed C7--

ý

ý 60orifed QWas00Entath CEOlRICATE Of 94SPICTION I. the undersigned, holding a valid commission lssued by ihs National Board at 501Wf arid N 5i-V9 O¶-5

~

the Stae" or Province of CONNECTICUr and emloe by OMR1 "q1t~

n of

BOSTON, M4ASS haev inspescted the pump. or valve, described in this Data Report on 06/01/00 adstate that to the beat of my knrowledge arnd belief. the Ceniart.fe Holder has can aurucue this pumnp, or valve, In accordancea with the ASME Code. Section Mll. Division 1.

By algnkig 0110 Certificate. nartherf the hiaSpect nar NO. employer makes any warranty, *Kpremeed or Imnplied. concerning the component deecribed In this Dais Report. Nnhannamioe.

neither the Inspector no' hMs employer shall be liable In any manner for any personal k*Nay at propm t Ammae awo a loam of any kind arising from or connected with this inspection.

Saeigned l-Coenmieslons N A qýc jC,4 i

lA-.Voii.Ad o actorl 14nl.likeL. Ond. enderemen-lel and stale or psray. and nel Ill For mar&Aa§V aperate valves only.

is.

145AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address ECO 179458, PCWO 344339 Repair Organization PO. No., Job No., etc.

Type Code Symbol Stamp None Aiuthorizatinn Nn N/A Expiration Date N/A

4. Identification of System I-I-U W - I I-SYS I EI-M -I 14
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, Winter 72 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, N-411 NO ADDENDA
7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
8. Tests Conducted:

Hydrostatic Pneumatic F

Nominal Operating Pressure D

Other El Pressure N/A psi Test Temp.

N/A

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant Date Sheet 1

of Unit 04/25/2002 ONE Code Case ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PIPE SUPPORT BECHTEL N/A N/A SPDBA103-1982 REPLACED NO H2000 PACIFIC 6668 N/A SPDBA103-1979 REPLACED N/A MECH SNUBBER SCIENTIFIC H2000 PIPE SUPPORT BECHTEL N/A N/A SPDBA107-1982 REPLACED NO H2000 SNUBBER PACIFIC 13970 N/A SPDBA107-1981 REPLACED N/A MECH SNSCIENTIFIC H2000 (12182)

ULtAZDO I t..,

Li'Mb

b I

FORM NIS-2 (Back)

9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.

1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 piping per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.

CODE CASE N-41 1 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date

/

, 20 Seror Own s

T upv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period to

-31

- (_/

to

-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken codre"'ive measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NFU 7 98 A. N,

?.3;F s P,4 z o 4 Inspecto r-ignature National Board, State, Province, and Endorsements Date.

V -"a 17 20 2 (in>

1q-

FORM R-1 REPORT OF WELDED REPAIR in accordance wsith provisions of the National Board Inspection Code

1. Work performed b NV PPL Susquehanna, LLC (name of repair organization) 707 Salem Blvd. Berwick, PA 18603 (address)

G02-147-002, 003, 004 (Form R No )

318013,318033,390136 (P 0 No Job No etc)

3. Location of installation PPL Susquehanna, LLC (ad. ressr PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)

(address)

4. Unit identification Feedwater Heater Name of original manufacturer (boiler, pressure vessel)
5. Identifying nos.:

01-06-54356-1 6362 570250 (mfg serial no)

(National Board No (

(jurisdiction no N BRIC Edition/Addenda:

2001 Original Code of C Construction Code

7. Repair Type:

Struthers Industries, Inc.

1E103A (other) 2001 2002 (year built)

(edition)

(addenda) onstruction for Item:

ASME Sec. VIII Div. 1 1998 Edition w/ 2000 Addenda (name/section/iciision; (edition/addenda)

Used for Repair Performed:

ASME Sec. VIII Div. 1 1998 Ed. w/ 2000 Add.

(name/sectiontdivisron)

(edition/acdenda)

  • ' Welded El Graphite Pressure Equipment El FRP Pressure Equipment
8. Description of work:

Welded repair of base metal damage on nozzles N2, N4, and N6.

(use supplemental sheet, Form R-4, rf necessary)

Pressure Test, if applied N/A psi MAWP 75 int./

15 ext.

psi

9. Replacement Parts: Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:

None (name of part, item number. data report type, mfr's name and identifying stamp)

10. Remarks:

Surface examination performed on weld preparation and final weld surfaces.

I, i*kp),-

/;/e-y

, holding a valid Commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of _

Pennsylvania and employed by Factory Mutual Insurance Company of Johnston. Rhode Island have inspected the work described in this report on

.OO and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board Inspection Code.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

Date C Signed Commissions

  • Ikl~landl iaridrtion, and no~m t)
2. Owner CERTIFICATE OF COMPLIANCE I,

E CAh-- ', /

.* certify that to the best of my kno\\,.ledge and belief the statements in this report are correct and that all material, construction, and %%orkmanship on this Repair conforms to the National Board Inspection Code.

National Board "R" Certificate of Authorization No.

5449 expires on Novemb r 3 200 Date 3* /*a

,.?

Z--

PPL Susquehanna, LLC Signed __.____

/____

(name of repair organization)

()uthtrized Apre~entative)

CERTIFICATE OF INSPECTION

'National* Board fic endorsements)...

p and jurisdiction, and no)

(inspector)

--ý

FORM R-1 REPORT OF WELDED REPAIR in accordance wxith provisions of the National Board Inspection Code

1. Work performed "2. Owner
3. Location of installation PPL Susquehanna, LLC (name of repair organization) 707 Salem Blvd. Berwick, PA 18603 (address)

PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)

G02-147-005 (Form R No) 318490 PPL Susquehanna, LLC (name) 707 Salem Blvd. Berwick, PA 18603 (address)

4. Unit identification Feedwater Heater Name of original manufacturer (boiler pressure vessel)
5. Identifying nos.:

01-06-54356-3 6364 570252 (mfg serial no )

(National Board No oJurisdiction no)

6. NBIC Edition/Addenda:

2001 (edilii Original Code of Construction for Item:

A Construction Code Used for Repair Performed:

on)

SME Sec. VIII Div. 1 (namelsectionidivision, ASME Sec. VIII Div. 1 (nametsection/dsvison)

7. Repair Type:

Welded El Graphite Pressure Equipment

8. Description of work:

Welded repair of base metal damage on nozzle N1 Struthers Industries, Inc.

1E103C (olher) 2001 2002 (year built)

)adderrda)

(addenda) 1998 Edition w/ 2000 Addenda (editio92addenda) 1998 Ed. w/ 2000 Add.

(edition/addenda)

EZ FRP Pressure Equipment (use supplementai sheet, Form R-4, i necessary)

Pressure Test, if applied N/A psi MAWP 75 int. / 15 ext.

psi

9. Replacement Parts: Attached are Manufacturer's Partial Data Reports or Form R-3s properly completed for the following items of this report:

None (name of par, item number, data repon type, mfr's name and identifying stamp)

10. Remarks:

Surface examination performed on weld preparation and final weld surfaces.

CERTIFICATE OF COMPLIANCE

/.,certify' that to the best of my knowledge and belief the statements in this report are correct and that all material, construction, and workmanship on this Repair conforms to the National Board Inspection Code.

National Board "R" Certificate of Authorization No.

5449 expires on November 3

,1_200 Date 3/1Z e

.,o.0 72 PPL Susquehanna. LLC Signed (name of repair orwanizalron)

( !u rri ze,,

presentatise)

CERTIFICATE OF INSPECTION 1_,..--

holding a valid Commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of co~ipetency issued by the jurisdiction of Pennsylvania and employed by Factor' Mutual Insurance Company of Johnston, Rhode Island have inspected the work described in this report on '.Y -

-3

, 2- 0 4.

and state that to the best of my knowledge and belief this work complies with the applicable requirements of the National Board Inspection Code.

By signing this certificate, neither the undersigned nor my employer makes an), warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my' employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

Date 3,

,d.

0.Signed Commissions

/,..-

5

/

(inspect (National Board (incl endorse nents),

and jurisdiction, and no)

PPL Susquehanna, LLC (address) by' (PO0 No, Job No. etc )

149A-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant PO PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name Box 467 / 707 Salem Blvd., Berwick, PA 18603 Address
3. Work Performed by PPL Susquehanna, LLC.

Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 04-Jan-2001 1

Of 1

One WO's: C60007 & C60008 DCP's: 94-3023B & C Service Order: 140747-C Repair Organization P.O No-Job No, etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A

4. Identification of System 1t49A-.II,

'NeiUUdl I tCdL r*,XlI iuV0

5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 Ed. No Ad.
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or Componentdetiiaton Bul No)

RHR Motor Oil Cooler General Electric D90450-001D N/A 1E217B 1990 Replaced No RHR Motor Oil Cooler General Electric 94G620-001-05 N/A 1E217B 1994 Replacement No RHR Motor Oil Cooler General Electric D90451-001D N/A 1E217C 1990 Replaced No RHR Motor Oil Cooler General Electric 94G620-001-07 N/A 1E217C 1994 Replacement No RHR Motor Oil Cooler General Electric 94G620-001-06 N/A 1E217D 2000 Repaired No

7. Description of Work Replacement & Repair of RHR Motor Oil Coolers made of AL6XN materials.
8. Tests Conducted:

Hydrostatic E Pneumatic R]

Nominal Operating Pressure

-1 Other E-Pressure 300 psi Test Temp.

Ambient

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/

in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 04-Jan-2001 (12/82)

I--

FORM NIS-2 (Back)

9. Remarks Motor Oil Coolers were replaced during Unit 1, Cycle 9, and should have been included in the Unit I, 91h Outage Summary Report. The repair 1E217D Motor Oil was completed during the Unit I, 12'h RIO, and should have been included in the Unit I, 12 Outage Summary Report.

This condition is documented on Deficiency Report CR-266792.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this repairtreplacement conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed1 J$

Date Z

  • ,2001

&iOwnep6r OwneisJDe/aneTide Supv.. Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owners Report during the period Aug. 2-3 4 l/pP6 to

',V-. 9*7" 2.0.:

,/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions NVS A7-2.,

£-rg/VA' A

24,*

Inspector's Signot1'e National Board, State, Province, and Endorsements Date A/.)je' 200/

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Date Sheet Address Susquehanna Steam Electric Station Name Unit 04/25/2002 1

of ONE 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Address PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.

Expiration Date

4. Identification of System RESIDUAL HEAT REMOVAL SYSTEM 149C CLASS I
5. (a) Applicable Construction Code Asme Section III 19 71
Edition, Winter 72
Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Code Case
7. Description of Work
8. Tests Conducted:

REMOVE SNUBBER / NO REPLACEMENT Hydrostatic E Pneumatic E

Nominal Operating Pressure 1

Other l

Pressure N/A psi Test Temp.

N/A

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant Name 769 Salem Blvd, Berwick, PA 18603 149CI 1ON ECO 179459, PCWO 345105 Repair Organization P.O No., Job No., etc Type Code Symbol Stamp None N/A N/A ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PIPE SUPPORT BECHTEL N/A N/A SPDCA117-H14 1982 REPLACED NO PACIFIC MECH SNUBBER SCIENTIFIC 13470 N/A SPDCA117-H14 1981 REPLACED N/A 4

4 I

I

-I-1 1

4 4

-

1 1-I I

-r i

1

(12182)

FORM NIS-2 (Back)

9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda.

1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 pipincl per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date

~

-<~

20o2-

-owner o =wnr's Desig)

Title Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period C.-

_.7 _

to O 2-,

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

L--

1

    • Z 4

V:a

, V

)A

.27 Commissions N 9'79 80 A. N T..3 NS P4 -Lo4 Inspector'0Signature National Board, State, Province, and Endorsements Date 20

)

151A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 06/05/2002 1

of 1

One 769 Salem Blvd.; Berwick, PA 18603 Address DCP: 352940 PCWO 357240 Repair Organization P.O. No., Job No., etc.

3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Type Code Symbol Stamp Authorization No.

Expiration Date

4. Identification of System CORE SPRAY SYSTEM, 151A --GClass 11
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 Winter 72
Addenda, NONE Code Case 89 NO ADD.
6. Identification of Components Repaired or Replaced and Replacement Components
7. Description of Work
8. Tests Conducted:

Installation of new tubing to relocated instrument rack 1C057 Hydrostatic 0

Pneumatic Dý Other F

Pressure N/A Nominal Operating Pressure D-1 psi Test Temp.

N/A

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 1 Owner

2. Plant None N/A N/A ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (YesN or 318" STAINLESS BECHTEL N/A N/A JD-28-6-1A 1982 REPLACED YES STEEL TUBING RUN 3/8" STAINLESS PPL N/A N/A JD-28-6-1A 2002 REPLACEMENT NO STEEL TUBING RUN 3/8" STAINLESS BECHTEL N/A N/A JD-28-6-1B 1982 REPLACED YES STEEL TUBING RUN 3/8" STAINLESS PPL N/A N/A JD-28-6-1B 2002 REPLACEMENT NO STEEL TUBING RUN (12/82)

FORM NIS-2 (Back)

9. Remarks NONE Aol.icable Manufacturers Data Reoorts to be attacted CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date

, 20c, "--

owno n Oeesilee,74le Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period I-Z-

to 4-7/-71-Z

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C commissions N 1379 SO A.

1ý Ig-S f

4 zo4-.

Inspectoe ignature National Board, State, Province, and Endorsements DateJT

,'wE 21 200Z C

(

Q>

153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, Address DCP 318280; PCWO 319462, 319466, 319468, 319558. 346328 Repair Organization P.O. No, Job No, etc Type Code Symbol Stamp None DA 18603 Authorization No.

N/A Expiration Date N/A

4. Identification of System 153A - STANDBY LIUUIU
UNTI RUL Y> I t-M LL/AZ II
5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, See Remark Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Code Case N416-1 6-Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Small Pipe Flanges Bechtel N/A N/A SPDCB101-1 1982 REPLACED Yes Small Pipe Flanges PPL HT# C5257 N/A SPDCB101-1 2002 REPLACEMENT No Spring and Spring LONERGAN VALVE S/N N/A PSV148029A 1979 REPLACED Yes Step 510138-1-14-1 Spring and Spring LONERGAN VALVE S/N N/A PSV148029A 2002 REPLACEMENT No Step 510138-1-14-1 Small Pipe Flanges Bechtel N/A N/A SPDCB101-2 1982 REPLACED Yes Small Pipe Flanges PPL HT# HN051 N/A SPDCB101-2 2002 REPLACEMENT No Spring and Spring LONERGAN VALVE S/N N/A PSV148FO29B 1979 REPLACED Yes Step 510138-1-14-2

  • SEE REMARKS
7. Description of Work
8. Teests Conducted:

Hydrostatic E Pneumatic D

Nominal Operating Pressure t^

Other l

Pressure 1400 psi Test Temp.

72

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant 04/30/2002 Date Sheet Unit 1

of 3

1 (12/82)

FORM NIS-2 (Back)

9. Remarks Rerated the piping (SPDCB101-1, 2, 3, 4, 5, 6, 7, 8) pumps (1P208A/B) and valves (PSV148FO29A/B). Replace spring and step spring in PSV's. Replace the pump discharge flanges from 600# to 1500#. Install new (rerate nameplates) with new design pressure of 1500PSI on components.

Piping DCB-101; Valve PSV148FO29A/B. Replaced plunger in 1P208B.

Construction Code for LONERGAN:ASME Section III, 1974 Edition thru Winter 1974; Code Case N-1 555 Construction Code for SLC Pumps: ASME Section III, 1968 Edition.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code,Section XI.

Type Code Symbol Stamp Repair Replacement conforms to the rules of the repair or replacement N/A Certificate of Authorization No.

N/A Expiration Signed Owner orfwner's DesikF,6. Ttle Supv. - Site Modifications Group Date

'\\-Z

_ /I.-

N/A

.20 O6 CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND ha~e ins pted the.omponents described in this Owners Report during the period

- &J5-1 to S.

_T-0-.

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

(1,ý4' Z

z7 Commissions NO79 80 A. N, r. 13 -. iNi PA C Ot.

lnspectoCoSignature National Board, State, Province, and Endorsements Date. J'uNv, I 7 200 Z.

/0q,

153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant PPL Susquehanna, LLC.

Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susque Na 769 Salem Blvd, Berwick, F Address
4. Indentification of System Date Sheet Unit 04/30/2002 2

of 2

1 DCP 318280; PCWO 319462, 319466, 319468, 319558, 346328 Repair Organization P.0 No, Job No., etc.

hanna, LLC.

Type Code Symbol Stamp None me PA 18603 Authorization No.

N/A Expiration Date N/A 153A - STANDBY LIQUID CONTROL SYSTEM CLASS II (a) Applicable Construction Code III 19 71

Edition, thru W'72
Addenda, See Remark Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 Code Case N416-1
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Spring and Spring LONERGAN VALVE S/N N/A PSV148F029B 2002 REPLACEMENT No Step 510138-1-14-2 Stud Bolt/Nut Bechtel N/A N/A SPDCB101-1 1982 REPLACED Yes Stud Bolt/Nut PPL Stud Bolt N/A SPDCB101-1 2002 REPLACEMENT No HT#04617; Nut HT#HDF Stud Bolt/Nut Bechtel N/A N/A SPDCB101-2 1982 REPLACE Yes Stud Bolt/Nut PPL Stud Bolt N/A SPDCB101-2 2002 REPLACEMENT No HT#04617; Nut HT#HDF SLC Pump "A" Union S/N 284222 N/A 1P-208A 1973 REPLACED Yes SLC Pump "A" Union S/N 284222 N/A 1 P-208A 2002 REPLACEMENT No SLC Pump "B" Union S/N 284223 N/A 1 P-208B 1973 REPLACED Yes SLC Pump "B" Union S/N 284223 N/A 1P-208B 2002 REPLACEMENT No Piping Isometrics Bechtel N/A N/A N/A 1982 REPLACED Yes SPDCB 101-3, 4, 5,

6. 7 and 8 5.

153AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC.

Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address 3, Work Performed by PPL Susquehanna, LLC.

Name 769 Salem BlVd, Berwlck, Address Date Sheet Unit 04/30/2002 3

of 3

1 DCP 318280; PCWO 319462, 319466, 319468, 319558, 346328 Repair Organization P.O. No., Job No., etc Type Code Symbol Stamp None DA 1 8bU3 Authorization No.

NIA Expiration Date N/A

4. Indentification of System 153A - STANDBY LIQUILD CONTROL SYS I EM CLASS II
5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, See Remark Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Code Case N416-1
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Piping Isometrics PPL N/A N/A N/A 2002 REPLACEMENT No SPDCB10I-3, 4, 5, 6, 7 and 8 PLUNGER Union SIN 284223 N/A 1P-208B 1971 REPLACED Yes PLUNGER Union SIN 284223 N/A 1 P-208B 2002 REPLACEMENT No SPDCBIOI-H37 Bechtel N/A N/A SPDCB101-H37 1982 REPAIRED No

1. Owner
2. Plant

161 B-Ill FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 06/05/2002 1

of One 769 Salem Blvd.; Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd.; Berwick, PA 18603 Address PCWO 267546 & 189828 Repair Organization P.0 No., Job No., etc Type Code Symbol Stamp None Authorization No.

Expiration Date N/A N/A

4. Identification of System REACTOR WATER CLEANUP, 161B -- Class III
5. (a) Applicable Construction Code Draft ASME 19 68
Edition, Pump & Valve (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89,NO ADD.
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, NONE
7. Description of Work
8. Tests Conducted:

REPLACED PROXIMITY PROBES WITH PIPE PLUGS ON PUMP MOTOR U12H91823 Hydrostatic E Pneumatic D

Nominal Operating Pressure Other El Pressure psi Test Temp.

Dl

.F NONE CONDUCTED NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/

in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant Code Case ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PROXIMITY PROBE HAYWARD U12H91823 N/A SPARE(PUMP) 1991 REPLACED NO (4 EA.)

TYLER (PUMP MOTOR)

PLUG (4 EA) -1/2" BONNEY N/A N/A (1)--HT. # 9162 1998 REPLACEMENT NO (3) - HT. # 9204 1999 1/4"PROXIMITY HAYWARD U12H91823 N/A SPARE (PUMP) 1991 REPLACED NO PROBE -(2 EA.)

TYLER (PUMP MOTOR)

PLUG (2EA) - 1/4" BONNEY N/A HEAT #CK43 1984 REPLACEMENT NO

1

t 1-1 1

t (12/82)

FORM NIS-2 (Back)

9. Remarks NO CODE DATA REPORTS ARE APPLICABLE TO THE PIPE PLUGS USED TO REPLACE THE PROXIMITY PROBES IN ACCORDANCE WITH PCWO's 189828 & 267546, AND DCP 224005 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date 200- L.

0Oter or Owner's D Ir Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have insp ct d the components described in this Owner's Report during the period II

-I

(

)

to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C JD7?-i Commissions Nk? 7'700 A.

F.4 Z Zt o0 Inspector's 11fgfature National Board, State, Province, and Endorsements Date U'U" a Z 1 20 0 '2.

)

9

162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
4. Identification of System 162A, F Date Sheet Unit 4/25/2002 of 3

One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A Reactor Vessel; Class 1

5. (a) Applicable Construction Code I11 19 71
Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
7. Description of Work
Addenda, 1535-2 Code Case Improve seating characteritics and maintainability of MSIVs
8. Tests Conducted:

Hydrostatic ElJ Pneumatic 1

Nominal Operating Pressure F-SE-100-002 Other 0

Pressure 1037 psi Test Temp.

147

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner Name Two North Ninth St., Allentown, PA 18101
2. Plant ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 1-221 NA HV141FO22A 1974 Replaced Yes 26" MSIV Atwood & Morrill 1-221 NA HV141F022A 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141FO22A 2001 Replacement No nut assemblies)

Poppet Welding 245951-5 NA HV141FO22A 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-3 NA HV141F022A 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-5 NA HV141F022A 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO22A 2001 Replacement No (12/82)

FORM NIS-2 (Back)

9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.

National Board Forms NR-1 and ASME Forms N-2 are attached.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair/Replacement conforms to the rules of the ASME Code, Section X1.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Sig d Date &;

20' V 2

,Owne(r Owper's Des )e, Ttle Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period Z, - Z 8- 0Z to 6 -

  • 4-0 7.

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

(9J?

""z

's Commissions NS 7980 A,.,r. UAI" PA *Z.-0+

InspectcK Signature National Board, State, P'rovince, and Endorsements Date t-Z*

2002-r(N>

162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 4/25/2002 2

of 3

One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A

4. Identification of System 162A, Reactor Vessel; Class 1
5. (a) Applicable Construction Code III 19 71
Edition, thru S' 71
Addenda, 1535-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 2-221 NA HV141F022B 1974 Replaced Yes 26" MSIV Atwood & Morrill 2-221 NA HV141F022B 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141FO22B 2001 Replacement No nut assemblies)

Poppet Welding 245951-4 NA HV141F022B 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-5 NA HV141FO22B 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-7 NA HV141FO22B 2002 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141F022B 2001 Replacement No 26" MSIV Atwood & Morrill 3-221 NA HV141FO22C 1974 Replaced Yes 26" MSIV Atwood & Morrill 3-221 NA HV141FO22C 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141 F022C 2001 Replacement No nut assemblies)

Poppet Welding 245951-8 NA HV141FO22C 2001 Replacement Yes Services, Inc

162A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station 769 Salem Name Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 4/25/2002 3

of 3

One PCWO 345780, 345876, 345886, 345891 DCP 316329, 316330, 316331, 316332 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A

4. Identification of System ioLMk, Reactor vessel;,Clas I
5. (a) Applicable Construction Code III 19 71
Edition, thru S' 71
Addenda, 1535-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.

T r

1 National Board No.

Other Identification Year Built

Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No)

Bonnet Cover Atwood & Morrill H3391-8 NA HV141FO22C 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-8 NA HV141FO22C 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141 F022C 2001 Replacement No 26" MSIV Atwood & Morrill 4-221 NA HV141FO22D 1974 Replaced Yes 26" MSIV Atwood & Morrill 4-221 NA HV141F022D 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F022D 2001 Replacement No nut assemblies)

Poppet Welding 245951-9 NA HV141FO22D 2001 Replacement Yes Services, Inc Bonnet Cover Atwood & Morrill H3391-9 NA HV141F022D 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-9 NA HV141F022D 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO22D 2001 Replacement No

1. Owner
2. Plant

FORM NR-1 REPORT OF REPAIR A MODIFICATION El OR REPLACEMENT

]

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah, GA 31405 (address)
2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Niles North of Berwick, PA Salem Twp, PA
4. System 1-62A HV141F022A Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

9 10 11 12

5. b: Items Intstalled During Replacement Activities See Attached Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/

Code)

Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s)

Class 5a Item No.

Division

6. ASME Code Section )GI applicable for inservice inspection:

1989 N/A N/A (edition)

(addenda)

(Code Caess))

7. ASME Code Section XI used for repairs, modifications, or replacements:

19q89q N/A N/A (edition)

(addenda)

(Code Cases(s))

8. Construction Cdusdfrrepairs, modifications, orreplacements:

191S7 N/

C(edition)

(addenda)

(Code Cases(s))

9. Design responsibilities:

Atwood & Morrill Co.

10. Tests conducted: hydrostatic D]

pneumatic [] design pressure ID pressure N /A psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

ue.pDescriptioneofrework:ed (use of properly identified additional sheetqs) or sketch(es) is acceptable)

12. Remarks:-

See Attached CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-86 to use the "NR" stamp expires 5/25 2003 NR Certificate Holder Continental Field Systems, Inc Date 6 11 2002 Signed L 4 71"' 6M J Quality Control Manager (authorized representative)

(tite)

CERTIFICATE OF INSPECTION I,

,/j,"a.AM r, 0o96C.J" 1U7, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of P N/& Y. Vq-4N-4 and employed by 9CTO.Y MuTuA.L :rNs4Avrc&h

<:,tlPANy of JOHP4,o

.roN have inspected the repair, modification or replacement described in this report on 0

and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

DateTW(

+" re O, Signed A.,/g

0.

n -,-

CommissionsAJ798OAIJT. TAS /*4 Zo4 (mspetora (National Board (incl. ecdorsernents), jurisdiction, and no.)

See Attarhpdl work:

11. Description of

Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9"' St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A Items Which Required Repair, Modification, or Replacement Activities Identification Job Number 3218 Type of Item Mfg Name Mfg Serial Nat'l F H#

I No Items Installed During Replacement Activities Construction Code IU c

Ldtl 1 l_

_tl_

Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced WSI 5

N/A N/A N/A 2001 I11 NB 71 Ed. S71 A N/A I

Bonnet Replaced A&M 3

N/A N/A N/A 2001 111 NB 71 Ed. $71 A N/A l

Pilot Poppet Replaced A&M 5

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 I11 NB 71 Ed. S71 A N/A I

I of 2 Form NR-1 Attachment

Form NR-1 Attachment Report of Repair / Replacement W orked Performed by Continental Field Systems Job Number 3218 2' Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 "h St., Allentown. Penmsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022A

6. ASME Code Section XI applicable for inservice inspection: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

7. ASME Code Section XI used for repairs, modifications, or replacements:1989 N/A N/A (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 Summer 71 1

(edition)

(addenda)

Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production r

Pg. 1 of 2

1.

Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificate Holder)

2.

Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address or Purchaser)

3.

Location of installation PPL Susauehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)

4.

Type:

A & M Dwg D-SA 105 Gr.II 70.0 Ksi N/A 2001 32467-622 R17 (drawing no.)

(matl. spec. no.)

(tensile strength)

(CRN)

(year buiLl)

5.

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6.

Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7.

Remarks:

21" MSIV Valve Poppet SA 105 Gr.I with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat#245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21

8.

Nom. Thickness (in.)

N/A Min. design thickness (in.)

N/A Dia. ID (ft & in.)

21"Noma Length overall (ft & in.)

31' 00

9.

When applicable. Certificate Holder's Data Reports are attached for each Item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Seral Number Board No.

In Numerical Order In Numerical Order (1) 245951-1 (26)

(2) 245951-2 (27)

(3) 245951--4 (28)

(4) 245951-5 (29)

(5) 245951-7 (30)

(6) 245951-8 (31)

(7) 245951-9 (32)

(8)

(33)

(9)

(34)

(10)

(35)

(36)

(12)

(37)

(3 (38)

(14)

-- 39 (15)

(0 (16)

(41)

(17)

(42)

(18)

(43)

(19)

(44)

(20)

(45)

(21)

(46)

(22)

(47)

(23)

(48)

(24)

-(49)

(25)

(50)

10.

Design pressure N/A psi Temp.

N/A

  • F Hydro. test pressure N/A at temp. 'F Design~~~~(we prsueNA

~

l ep applicable)

- Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8'A/ x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairrield, NJ 07007-2300.

Reprint (7/91) 1V.Jbrary~svr~quafly..a Project Files lAtwood & MorriIt20011i3 1140 )Oct 200 1)W2-31 140. doc

FORM N-2 (Back - Page 2 of 2

Certificate Holder's Serial Nos.

Ht # 245951 through 1.2,4.5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by' Boyd P. Brooks P.E. State (when applicable)

Design Report* certified by Herbert Cook P.E. State (when applicable)

CA Reg. No.J 13655 MA Reg. No.

10981 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV conform(s) to the rules for construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N-2873 Date 12-10-01 Name Welding Services Inc.

SigneC (NPT Cerlificate Holder)

j. ~i (auhoize reoresentaSIN)

CERTIFICATE OF INSPECTION.

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code, Section Ill.

Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspecto s employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this inspion.

Comsin NB'

-H

-AAAtN UW Date 122-10-01 Signed Commissions NB # 11465 ABN, GA b

3

[Natl. 8d. (incl. Endorsements) and state or proy, and no.]

%VUibrary svr~quality a Project FiestAtwood & MorrimU2001 31140 )Oct 2001)W2-31140.doc I

J SValve Poppets x irs Noe r 13,2W04 LO,

,.°

.1

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
2. Manufactured for Pennsylvania Power& Light Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32162-409-D Rev. 1 SA 105 GR II 81,600 PSI N/A 2001 (drawing no.)

(marl. spec. no.)

(tensile strength)

(CRN)

(year buiM

5. ASME Code,Section III, Division 1:

1971 S71 1

N/A (idibon)

(addenda date)

(class)

(Code Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.0. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Nom. Thickness (in.)

5.312 Min. design thickness (in.)

5.094 Dia. ID (ft & in,)

N/A Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

(1)

(2)

P, (3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

-(*3 (14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Part or Appurtenance Serial Number HT: H3391 SIN 1 HT: H3391 SIN 2 HT: H3391 S/N 3

10. Design pressure National Board No.

In Numerical Order N/A N/A N/A Part or Appurtenance Serial Number (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37) 1381 National Board No.

j4iLiL

4.

(39) 1250 psi.

Temp.

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50) 575

  • F. Hydro. test pressure N/A (whoen applicable)

-Supplemental Information in the form of lists, sketches. or drawings may be used provided (1) size is a %x i 1. (2) Information If items 2 and 3 on this Data Report Is Included on each sheet is numbered and the number of sheets is recorded at the top of this form.

(12188)

This lorm (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07D07.2300.

Reprint (7IS1) in Numerical Order At temp. "F

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 1 through S/N 3 CERTIFICATION OF DESIGN Design specifications certified by N/A (when apphicable)

Design report

  • certified by N/A (whfle applicable)

P.E. State N/A P.E. State N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Date N2607 Expires Name Atwood & Morrill Co., Inc.

(NPT Certificate Hold*,)

6-13-04 Signed A2~.~'~

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed oy of

Hartford, CT have inspected these items described in this Data Report on

/,

/

and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section 1, Division 1. Each part listed has been authorized for stamping on the date shown above.

y signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspect Date Signed 1

  • ý
XZ L

Commissions

,AJ 2.7-,,J A* AJ (autx)zaed inmpector

[Narl Bd. (ind. Ea*kmneints) and state or pmv. and no.]

Cover (a tnzedl repro" tiv)

U.C*IZIJIL.I r.n S=

I L-.

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT C1rtiflcate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)

(marl. spec. no.)

(tensile strength)

(CRN)

(yew built)

5. ASME Code, Section I11, Division 1:

1971 S71 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Fabricated in accordlance with Const, Spec. (Div. 2 only)

N/A' Revision N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121_QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section I1l 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& in.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:

Part or Appurtenance Serial Number (1)

HT: 54682 S/N 1 (2)

HT: 54682 S/N 2 (3)

HT: 54682 S/N 3 (4)

HT: 54682 S/N 4

5)

HT: 54682 S/N 5 (6)

HT: 54682 S/N 6 (7).

HT: 54682 S/N 8 (8)

HT: 54682 S/N 9 (9)

(10)

(11)

(12)

(14)

(15")

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

10. Design pressure National Board No.

In Numerical Order N/A N/A N/A N/A N/A N/A N/A N/A 1250 psi.

Temp.

Part or Appurtenance Serial Number (26)

(27)

,(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

National Board No.

In Numerical Order NI/A At temp. "F C.

(iJUIS,. 

r'-

Vr. Fly 10.

F.,

(when applicable)

'Supplemental Information in the form of lists, sketches, or drawings may be used provided [1) size Is 8 'A x 1i, j21 Information In Items 2 end 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(12188)

This form (EOOO40) may be obtained from the Order Dept. ASME, 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300.

Reprnt (71911

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by N/A (when applicable)

Design report

  • certified by N/A (when applicable)

P.E. State P.E. State N/A N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III. Division 1.

NPT Certificate of Authorization No.

Date

-4 L

Pilot Poppet N2607 Expires Name Atwood & Morrill Co., Inc.

(NPT Car.ificat Hoalor)

(audwrttifld pis at CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and'Pressure Vessel Inspectors and the State or Province of I. U 1 9 I 0

e-New York And employed by

17.. D. I U.

of Hartford, CT have inspected these items described in this Data Report on

,*2,,l7 and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accorddncefwith the ASME Code, Section

,,Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Signed Commissions

[,oriz~d inspector)

-Narl 0d. (wmx. Endowsmnerts} and sta or pt o

v. and no]

6-13-04

,t

FORM NR-1 REPORT OF REPAIR []

MODIFICATION ]

OR REPLACEMENT NI TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah, GA 31405 (address) 2.0wner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA Salem Twp, PA 4.System 1-62A HIV4!F0 99B Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name!

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

9 10 11 12

5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/

Code Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section XI applfcable for inservice inspection:

1989 N/A NIA (edition)

(addenda)

(Code Cases(s))

7. ASME Code Section Xl used for repairs, modifications, or replacements:

1J89...

N1 A

-Al /

(edition)

(addenda)

(Cod; Caess))

8. Construction Code used for repairs, modifications, or replacements:

19 71 S

71]

N/A (edition)

(addenda)

(Code Cases s))

9. Design responsibilities:

Atwood & Morrill Co.

10. Tests conducted: hydrostatic E] pneumatic ]

design pressure [I pressureN4A._

psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

wueDesrrption ofyidrk:

SeAt ed (use of properly identified additional sheet(s) or sketch(es) is acceptable)

12. Remarks:_

See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XG of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-86 to use the "NR" stamp expires 5/25, 2003 NR Certificate Holder Cont*[ntntal Fit-ld Slvaopq_ T3i Date 6/18.

2002 Signed e)

Qualitv Control Mnnacpr CERTIFICATE OF INSPECTION I,

a/ i.. iAM F'. Zo 4; CK =

holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of 1'7-NA L tV,4

,1A and employed by

",,sc for u4.

EAV,,= uR, kca-C-'-,w, O

of 7 H'NS5toN4 9i1 have inspected the repair, modification or replacement described in this report on 4 - I ZOO and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codv and the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

Date &H oZ ZOOZ.

Signed&L f ik'r"/.Th?,zS.*A2i" CommissionsLJW799OA."*,

M.

,4gZ 4

(inspector) e (National Board (incl. endorsements), jurisdiction, and no.)

(title)

See Attached wnrk:

11. Description of (authorzed representative)

Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B Items Which Required Repair, Modification, or Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Items Installed During Replacement Activities MFG.

Name WSI Mfg. Serial No.

4 Nat'l Bd. No.

N/A Jurisd. No.

N/A Other N/A Year Built 2001 Name/

Section/

Division III NB Construction Code Edition/

Addenda 71 Ed. S71 A Code Case(s)

Bonnet Replaced A&M 5

N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I

Pilot Poppet Replaced A&M 7

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Code Class A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A o f2 Identification Item Poppet Installed/

Replaced Replaced Super Nuts Replaced 0

l

Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems Job Number 3218

(

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9t1 St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022B

6. ASME Code Section Xl applicable for inservice inspection: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 Summer 71 1

(edition)

(addenda)

Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Sreplace with new components from OEM as part of valve enhancement.
12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg.l1of 2

Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA 30071 (name and address of NPT Certificate Holder)

2.

Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)

3.

Location of installation PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603

( n*TKam and address)

4.

Type:

A&MDw D-SA 105 Gr.11 70.0 Ksi N/A 2001 32467-622 R17(RN(y bl)

(drawing no.)

(matl. spec. no.)

(tensile slrenglh)

(CRN)

(year buill)

5.

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A

("dilion)

(addenda dale)

(class)

(Code Case no.)

6.

Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7.

Remarks:

21 MSIV Valve poppet SA 105 Gr.ll with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 2459 5 1 for SA 105 Gr. II "Heat #s 00-21-01, 00_21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21 8,

Nom. Thickness (in.)

N/A Min. design thickness (in.)

NIA Dia. ID (ft & in.)

21'Nom.

Length overall (Ift in.)

31

9.

When applicable, Certificate Holder's Data Reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

(

In Numerical Order In Numerical Order (1) 245951-1 (26)

(2) 245951-2 (27)

--.J13) 245951-4 (28)

(4) 245951-5 (29)

(5) 245951-7 (30)

(6) 245951-8 (31)

(7) 245951-9 (32)

(8)

(33)

(9)

(34)

(10)

(35)

(11)

(36)

(12)

(37)

(38)

(14)

(40)

(15)

(40)

(16)

(41)

(17)

(42)

(18)

(43)

(19)

(44)

(20)

(45)

(21)

(46)

(22)

(47)

(23)

(8 (24)

(49)

(25)

(50)

10.

Design pressure NIA psi.

Temp.

NIA F

Hydro. test pressure N/A at temp. 'F

(______(when applicable)

'Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8'A x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (EO0040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

Reprint (7191) 1\\UJbrary_svr(quafiy_ a fProject FilesoAtwood & MornhI20 0 1131U"40 )Oct 2001)W2-31140.doc

FORM N-2 (Back - Page 2 of 2 )

Certificate Holder's Serial Nos.

Ht # 245951 through 1,2,4,5,7,8,9 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code,Section III, Division 1.

NPT Certificate or Authorization No.

N-2873 x ires Nove r 13, 2004 Date 12-10-01 Name Welding Services Inc.

Sign Lui.-

o k (NPT Certificate Holder)authorized representative CERTIFICATE OF INSPECTION.

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code,Section III, "livision 1. Each part listed has been authorized for stamping on the date shown above.

.... r Nhis ernnlnver makes any warranty. expressed or Implied, concerning the equipment described By signing this certinlc te, neither th ns,.,.p

,,v,..

-,z in this Data Report. Furthermore, neither the insp hi mployer-shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this insp ion.

r% f.

12-10-0l1 Signed Commissions NB #11465 ABN.

GAW 393 edn

\\jbrary.svrlquaity.a Project Flies lAtwood & MorriMll200 131140 )Oct 2001)W2-31140.doc I~~~Natl.

Bd. (incl.l E:ndorsements) arm state, or ro-.-,

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and addresS of NPT CerUtflcat Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32162-409-D Rev. 1 SA 105 GR II 77,900 PSI N/A 2001

~~~~1

.,t-t y ar W inl (draw.ng no.)

5. ASME Code,Section III, Division 1:

(Marl. Spec. no.)

a 0"'1 (tensile ength)

.q71 1

N/A

"(edibon)

(addenda date)

(Class) t a 9

,,a.,

Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

Remarks:

Gust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda Nom. Thickness (in.)

5.312 Min. design thickness (in.)

5.094 Dia. ID (ft & in.)

N/A Length overall (rt& in.)

N/A When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No:

Serial Number Board No.

In Numerical Order In Numerical Order HT: H3391 S/N 4 NJA HT: H3391 S/N 5 N/A HT: H3391 S/N 6 N/A (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

.(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

10. Design pressure 1250 psi.

Temp.

575

'F. Hydro. test pressure

"-Supplemental Information In the form of lists, sketches, or drawings may be used provided (I) size is B 'V x 11, 12) Information In items 2 and 3 on this Data Report is included an each sheet Is numbered and the number of sheets is recorded at the top of this form.

(12)88)

This lorm (E00040) may be obtained from the Order Dept., ASME. 22 Low Drive. Box 2300, Fairfield. NJ 07007-2300.

Reprint (7191)

6.
7.
8.

9.

(1)

,-(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A (when applicable)

At temp. F II =

I

-1

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 SIN 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by Design report

  • certified by N/A (when applicable)

N/A 1when applicable)

P.E, State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N2607 Reg. no.

Reg. no.

Cover Expires Atwood & Morrill Co., Inc.

(NPT Certficate Hold"er Signed

-r S(a=lonzed foprosonitat.ne)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.

Hartford, CT have inspected these items described in this Data Report on Z,.,,/,,$'

, and state that to the

-st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord'ance'with the ASME Code, Section il, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date

,V Signed

_Commissions

,.V>'r7e,

.,,q J N/A N/A Date Name Npew York 6-13-04_

(authorized inspector)

"//I

[Narl 8d. (incl, Endorsernetil'J and s;tate or prey. and: no.I

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

'. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 4fidmt aIiU aDorn. vi flrl tCitiflCIt* rroiosr

2name and aturess ofe Nfe i

PAertfcate 1l860er)

2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603

nam..nu.our.ssoi rurcnaser, 3name Stre aeress A

fe ntwnPaser)

3. Location of installation Susquehanna 11 2 North Ninth Street Allentown, PA 18101-1179 (name and eaddress)
4. Type:

"32462-613-C Rev.0 SA 479-304 85.700 PSI 8570PIN/A 2002fl rawnrg no.)

5. ASME Code,Section III, Division 1:

(marl. spec. no.)

1971

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

(tensile strength)

S71 jaooenoa oate)

N/A (no.)

Revision (CRN) 1 N/A (class)

N/A (year built)

(Code Case no.)

Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 1 Pilot Poppet A&M P/N 32462-613-4226-121_QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addend*

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A Length overall (ft& in.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance Serial Number HT: 54682 S/N 7 National Board No.

In Numerical Order N/A 4.

4-4.

Part or Appurtenance Serial Number (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(4S)

(46)

(47)

(48)

(49)

(50)

National Board No.

In Numerical Order

+

4-

+

4-

.4.

.4.

+

.4.

-I.

+

4.

+

4-1-

-4.

.4.

1-4.

I

). Design pressure 1250 psi.

Temp.

575

'F.

Hydro. test pressure "Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size Is 8 'A x 11, (2) information In Items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

This form (E0O0040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

.(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A (w'hen epplicable)

At temp. "F Pg. 1 of.2 Pc. 1 of.2 N/A 1

N/A (121`11)

Reprint (71 91)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 7 through N/A CERTIFICATION OF DESIGN Design specifications certified by Design report

  • certified by N/A (wh~en applicable)

N/A (when applicable)

P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

Pilot Poppet NPT Certificate of Authorization No.

Date N2607 Expires Name Atwood & Morrill Co., Inc.

(NPT Certificate Holder) 6-13-04 Signed (aufo~hzed-representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by HSBCT of Hartford, CT have inspected these items described in this Data Report on i

, and state that to the 11'st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in acco(dande with the ASME Code, Section

)ivision 1. Each part listed has been authorized for stamping on the date shown above.

signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, conceming the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date 1

C s

Signed7..-.

Commissions 70..

En-oran" w or.

[NatI lad. (incl. Endorsennents) A~d stte or prov. and no.)

Reg. no.

Reg. no.

N/A N/A New York

FORM NR-1 REPORT OF REPAIR [k MODIFICATION L]

OR REPLACEMENT [X]

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah.

GA 31405 (address)

2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Milp* North of Rprwirt-k, PA Ralem Twp, PA 4.System 1-62A HV141FO22C MainSteam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

9 10 11 12

5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.

M~fg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/

Code Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section XI applfcable for inservice inspection:

19.8 9 N/A N/A (edition)

(addenda)

(Code Cases(s))

7. ASME Code Section XG used for repairs, modifications, or replacements:

1o9 N/A N/A (ediion)

(addenda)

(Code Cases(s))

rl

8. Construction Code used for repairs, modifications, or replacements:

19g 71 S-71]

N/A (edition)

(addenda)

(Code Cases(s))

9. Design responsibilities:

Atwood & Morrill Co.

10. Tests conducted: hydrostatic E] pneumatic El design pressure []

pressureN/.L psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

_____ I

I--

11 Descrrintinnofwnrk:

See Attarpchl (use of properly identified additional sheet(s) or sketch(es) is acceptable)

12. Remarks:

See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I, David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-8 6 to use the "NR" stamp expires 25 5

2003 NR Certificate Holder an /--t I FIM1 RXr T-. nc Date 6Qsrfy Cnt--l M/1a2r0 (authorized representative)

(ttle)

CERTIFICATE OF INSPECTION I, W(It-Y"AAi'*

?6O6{'

77.

holding a valid commission issued bjy The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of b"A'YNIY. YVAV/,4 and employed by

&7bThY M

rUuA

-L AJSLJRAA,rLcC/;

m~

-of U0T MSH A

lS Ib X

have inspected the repair, modification or replacement described in this report on A4tI..

0-,

and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codwand the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

Date(yWc) 2Z OO ti2 Signed 6idao.1)?

ComriissiiosM?

O4&r8,WS PAZn O+

(inspector),//

(National Board (icl-endorsements), jarisciction, and no.)

Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C Items Which Required Repair, Modification, or Replacement Activities Identification Job Number 3218 Construction Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.

Jurisdiction Other Year Name/ Section/

Edition /

Code Code Class Repair/

No.

No.

Built Division Addenda Case(s)

Replace I

MSIV A&M 3-221 N/A N/A N/A 1974 ASME lII/NB 1971/S71 1535-2 I

Repair 2

Items Installed During Replacement Activities Identification Construction Code Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced WSI 8

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Bonnet Replaced A&M 8

N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I

Pilot Poppet Replaced A&M 8

N/A N/A N/A 2001 III NB 71 Ed. 871 A N/A I

Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I

f2 Form NR-1 Attachment

Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Report of Repair / Replacement Job Number 3218 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022C

6. ASME Code Section XI applicable for inservice inspection: 1989 N/A NI (edition)

(addenda)

(C

7. ASME Code Section XI used for repairs, modifications, or replacements:]1989 N/A (edition)

(addenda)

8. Construction Code used for repairs, modifications, or replacements:

1971 Summer 71 (edition)

(addenda)

A ode Case(s))

N/A (Code Case(s))

I Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A 1I. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and C

replace with new components from OEM as part of valve enhancement.

12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2

1.
2.
3.
4.
5.
6.

7.

10.

Design pressure NIA psi.

Temp.

NIA

  • F Hydro. test pressure N/A at temp. F (when applicable)
  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8%A x 11, (2) information in items 2 and 3 on this Data Report is included ori each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (EO0040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 Reprint (7/91:

V~jbrary svrquafit~y aProject FiestAtwood & Mornlr200 1U31140 )Oct 200 1)W2-31140.doc Manufactured and certified by Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificale Holder)

Manufactured for Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)

Location of installation PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)

Type:

A&MDwg SA 10 Gr.fl 70.0 Ksi N/A 2001 32467-622 Rf7 (drawing no.)

(mail. spec. no.)

(tensile strength)

(CRN)

(year built)

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

Fabricated'in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

Remarks:

21" MSIV Valve Poppet SA 105 Gr.Il with SFA 5.13Alloy21 Stellite2l Hardsurfacing. Heat# 245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21 Nom. Thickness (in.)

NIA Min. design thickness (in.)

N/A Dia. ID (ft & in.)

21 No.

Length overall (ft & in.)

31' 0o When applicable, Certificate Holder's Data Reports are attached for each Item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

In Numerical Order In Numerical Order

8.

9.

FORM N-2 (Back - Page 2 of 2

Certificate Holders Serial Nos.

Ht # 245951 through 1,2,4.5.7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by' Boyd P. Brooks P.E. State CA Reg. No_

13655 (when applicable)

Design Report* certified by Herbert Cook P.E. State MA Reg. No..

10981 (when applicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code, Section Il1, Division 1.

NPT Certificate of Authorization No.

N-2873 xpiresr 13, 2004 Date 12-10-01 Name Welding Services Inc.

Signe4 N I

.ý L.

3 I (NPT Cerlificate Holder)

\\

authorized reprerentalive)

--- ---.U...

CERTIFICAT uI INbFrIL, I IIJJn I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code,Section III.

D'ivision 1. Each part listed has been authorized for stamping on the date shown above.

"By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspectoror his employer, shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this insp*

,rtion.

Date 12-10-01 Signed Commissions NB # 11465 ABN, GA # 393 S(Authi

.Nati.

Bd. (incl. Endorsements) and stale or prov. and no.]

1V.ibrary_ssvr~quaity.a Project FilestAtwood & MornZlO1 t3 1140 )Oct 200 I)W2-31140.doc F

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address Or Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32162-409-D Rev. 1 (dr-avwg no.)

S. ASME Code,Section III, Division 1:

SA 105 GR II (marl. spe, no,)

1971 80.000 PSI (tensile strength)

S71 (eSOM)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

(Oadends Oats)

N/A (no.)

Icissal Revision N/A Date

!Code Case no.)

N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 2 Cover A&M P/N 32162-409-2974-000 QLA' (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Nom. Thickness (in.)

5.312 Min. design thickness (in.)

5.094 Dia. ID (ft & in.)

N/A Length overall (Rt& In.)

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:

N/A Part or Appurtenance Serial Number (1)

HT: H3391 SIN 7

-. (2)

HT: H3391 S/N 8 (3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

National Board No.

In Numerical Order N/A NIA

+

1 4

4 1-

+

1

4.

4 Part or Appurtenance Serial Number (25)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(3S)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

National Board No.

In Numerical Order

'I 4

10. Design pressure 1250 psi.

Temp.

575 IF. Hydro. test pressure "Supplemental Information in the form of lists sketches, or drawIngs may be used provided (1) size Is

.% x 11, 12) Information In items 2 and 3 on this Data Report is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

This form (EO0040) may be obtained from the Order Dept.. ASME, 22 Law Drive, Box 2300, Fairfield, N.J 07007-2300.

Reprint (7I 31)

N/A IGRN) 1 2001 (year buil)

N/A N/A (whan appiacable)

At temp. "F SA 105 GR 11 2001 l*ass?

(112191)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 7 through S/N 8 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A (when applicable)

N/A (when appiIklbIle P.E. State P.E. State CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Date

/zi4 Name N2607 Expires Atwood & Morrill Co., Inc.

(NPT Certifcate Holder) 6-13-04 Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.

-f Hartford, CT have inspected these items described in this Data Report on

,/

, and state that to the

,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section

,,I, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date A.1 Signed

_Commissions

_4-. X-_-

7e N/A N/A Reg. no.

Reg. no.

N/A N/A Cover New York (authorized inslpeto*

"(S~uth~ozed represetat")

(Narl 8d:. (inc. Endorsements) end state of prov. ari rno.i

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPI' Ce*tificate Holder)
2. Manufactured for Pennsylvania Power & Light
  • Berwick, PA.18603 (name and address of Purchaser)
3. Location of installation Susquehanna 11 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)

(marl. spec. no.)

(tensile stren-th)

(CRN)

(year built)

5. ASME Code,Section III, Division 1:

.1971 S71 1

N/A (edibon)

(addenda date)

(class)

(Code Cate no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA

&M S..

90168 prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& in.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report C

I %-I

10. Design pressure 1250
psi, Temp.

575

'F. Hydro. test pressure N/A At temp. F (when applicable)

  • Supplemental information In the form of lists, sketches, or drawings may be used provided (1) size Is a % x 11, (2) Information In Items 2 and 3 an this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(12188)

This lorm (E00040) may be obtained from the Order DepL. ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007.2300.

Reprint (TI S1)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by N/A (when sppica ble)

Design report* certified by N/A (when applicable)

P.E. State N/A P.E. State N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are c6rrect and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N2607 Pilot Poppet Expires Atwood & Morrill Co., Inc.

(NPT~ Certficate Holder)

Signed A

.tn-dý 7

a~ol~

t-rwtbI CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.

"Hartford, CT have inspected these items described in this Data Report on g,".7, /

, and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord rncerwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions

.fJX?"76 A

1 /

Date Name

,,ole

!poizdinpecor

-/7

./

  • 'Narl Bd. Cindl. en:kmroms) wnd sata or prow. and no.]

6-13-04 a

6-13-04

,,,t/

J

=

(auth~orzed rapfesetab")

FORM NR-1 REPORT OF REPAIRX]

MODIFICATION ED OR REPLACEMENT 1]

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, TNc 3218 (name of NR certifcate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd,

.Savannah, GA 31405 (address)

2. Owner PPL LLC (name) 2 North Nintb Strept, Allentnurn PA 1Rl01 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 M1-i N-rth nf Rprwirk PA Snlm Twp: PA
4. System 1-62A HV141FO22D Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

11 12

5. b: Items Installed During Replacement Activities

,See Ar~tnnhed Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/

Code Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section )a applicable for inservice inspection:

1989 N/

N/A

-(edition)

N

"(addenda)

""(Code Cas

$~))

7. ASME Code Section MI used for repairs, modifications, or replacements:

19 A N.

A-N/A (edition)

(addenda)

(Code Cases(s))

8. Construction Code used.for repairs, modifications, or replacements:

19 71 S 71 N/A (edition)

(addenda)

(Code Casess))

9. Design responsibilities:

Atwoodl & Morrill Co.

10, Tests conducted: hydrostatic El pneumatic El design pressure D]

pressureNJA__

psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

11. Description of work:

Sea Attairlprl (use of properly identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks: See Attached Manufacturer's Data Report I--

CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-86 to use the "NR" stamp expires 525.j/2 2003 NR Certificate Holder rrnn pntal Jeld Sytrws Inc Date 6.L1B.

2.0DI1L Signed

-a~d

~

)Qual1ity Conf~ aac

--(authohzed re-presentative)

V*-..

Ti]e: Maae CERTIFICATE OF INSPECTION I, Ws o. tA.

e-1?. r -i Br, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of F;eN N SYLV -

Ai 4

and employed by i.4cTgRy MUTrUA LVJLVC C-2 COMP',4/v' of Z'JOtrA,

"*r have inspected the repair, modification or replacement described in this report on 4

  • I Z 0 0 ?

and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Codeand the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

(inspec

ýZ ZOOZ Signed or?(

5 ?

nd0-s, urd-CommissionsA,87982A&Z DNS PAdZZo4 (inspector~'

(National Board (cin. endorsements), jurisdiction, and no.)

I A

Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D Items Which Required Repair, Modification, or Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Construction Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.

Jurisdiction Other Year Name/ Section/

Edition /

Code Code Class Repair/

No.

No.

Built Division Addenda Case(s)

Replace I

MSIV A&M 4-221 N/A N/A N/A 1974 ASME 11 fNB 1971/S71 1535-2 I

Repair 2

Items Installed During Replacement Activities Identification Construction Code Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced WSI 9

N/A N/A N/A 2001 111 NB 71 Ed. S71 A N/A].

flnnnot P anl grpd A

1kM q

N/A N/A N/A 2001 III NB 71 Ed. S/1 A N/A Pilot Poppet Replaced~ A&M 9

NA{

N/A N/A~

2001 111INB 71 Ed. S71 A N/A Super Nuts

~Replaced~ A&M NU-0 10 17 N/A N/A___

N/A 2002 111INB 71lEd. S71 A N/Aj I

j0f 2

I

Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems Job Number 3218

(

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 162A Valve HV 141 F022D

6. ASME Code Section X1 applicable for inservice inspection: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

7. ASME Code Section XI used for repairs, modifications, or replacements: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 Summer 71 I

(edition)

(addenda)

Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
12. Remarks: (3) appendages were attached to the poppet to facilitate installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1.

Manufactured and certified by

2.

Manufactured for

3.

Location of installation Welding Services, Inc. 2225 Skyland Court, Norcross GA. 30071 (name and address of NPT Certificate Holder)

Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)

PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)

4.

Type:

A&M D-SA 105 Gr.U 70.0 Ksl N/A 2001 32467-622 R/7 (drawing no.)

(mall. spec. no.)

(tensile strength)

(CRN)

(year built)

5.

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A (edition)

(addenda dale)

(class)

(Code Case no.)

6.

Fabricated'in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7.

Remarks:

21" MSIV Valve Poppet SA 105 Gr.ll with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat # 245951 for SA 105 Gr. I1 "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-NO832R125 for Stellite 21

8.

Nom. Thickness (in.)

N/A Min. design thickness (in.)

N/A

9.

When applicable, Certificate Holder's Data Reports are attached for each It Part or Appurtenance Serial Number

10.
  • Design pressure National Board No.

In Numerical Order

1 NIA psi.

Temp.

245951-1 245951-4.

4.

4.

4.

+

Dia. ID (ft & in.)

21' Nor.

Length overall (ft & In.)

31" o OD Part or Appurtenance Serial Number (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37) 4.

_________________________________ 4.

I1 i

National Board No.

In Numerical Order (40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

N/A "F

Hydro. test pressure N/A at temp. 'F (when applicable)

"Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8% x 11, (2) information in items 2 and 3 on this Data Report is included orn each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

Reprint (7/91 )

ttLjbrarysvrtquality aP*froject FiestArwood & MorrIIA2001%31140 )Oct 2001)W2-31140.doc 94,.S 1-1 2ArQ1

)AlQvi,.A 245951-5 245951-7 245951-8 245951 -g (1)

(2)

(3)

(4)

(5)

(6)

(8)

(9)

(10)

(11)

(12) 1 )4 (15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

')ArGXZiA I

245951-5 245951-7 245951-8 245951-9 I

FORM N-2 (Back - Page 2 of 2 )

Certificate Holder's Serial Nos.

Ht # 245951 through 1,2,4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by-Boyd P. Brooks P.E. State CA Reg. No.

13655 (when applicable)

Design Report* certified by Herbert Cook P.E. State MA Reg. No..

10981 (when applicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21" MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code,Section III. Division 1.

NPT Certificate of Authorization No.

N-2873 x res(J r 13, 2004 Date 12-10-01 Name Welding Services Inc.

Signe N I i

Lo t5.Q (NPT Cerlificate Holder)

(authorized representativ*)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code.Section III.

Division 1. Each part listed. has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected w11 this ins ion.

I Date 12-10-01 Signed Commissions NB # i1465 ABN, GA# 393 S(Aut i

I

.[Nall.

Bd. (incl. Endorsements) and state or prov. and no.]

%ibrarysvriquaity_a

%Project FilestAtwood & Morrl#l2001131140 )Oct 2001)W2-31140.doc I

i

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32162-409-D Rev. 1 SA 105 GR II 81,500PSI N/A 2001 (drawing no.)

(marl spec-no.)

isnaile strengthi)

(CRNM (year "M

5. ASME Code,Section III, Division 1:

1971 S71 1

N/A (odibon)

(addenda data)

(class)

(Coda Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 1 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) -Dw.

Repared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda B. Noa. Thickness (in.)

5.312 Min. design thickness (in.)

5.094.

DIa. ID (ft & In.)

N/A Length overall (ft& in.)

N/A

9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

In Numerical Order In Numerical Order (1)

HT: H3391 SIN 9 N/A (26)

(2)

(27)

(3)

(28)

(4)

(29)

(5)

(30)

(6)

(31)

(7)

(32)

(8)

(33)

(9)

(34)

(10)

(35)

(11)

(36)

(12)

(37)

(13) --

"3)

(14)

(39)

(15)

(40)

(16)

(41)

(17)

(42)

(18)

(43)

(19)

(44)

(20)

(45)

(21)

(46)

(22)

(47)

(23)

(48)

(24)

(49)

(25)

(50)

10. Design pressure 1250 psi.

Temp.

575

'F.

Hydro. test pressure N/A Attemp.

_F (when applcable)

  • Supplemental Information In the form of lists, sketches, or drawings may be used provided (1) size is S Y. x i. (2) Information In items 2 and 3 on this Data Report IS Included on each sheet Is numbered and the number of sheots Is recorded at the top of this form.

(121881 This form (E00040) may be dibtained from the order Dept.. ASME. 22 Low Drive, sox 2300, Fairfield. NJ 07007-2300.

Reprnt (71 51)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 9 through SIN N/A CERTIFICATION OF DESIGN ions certified bv N/A P.E. State N/A Reg. no.

N/A Design report certified by N/A (whein applicable)

P.E. State N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Date N2607 Name Atwood & Morrill Co., I (NPT Cartifate H-ker)

Expires 6-13-04 ri.

Signed CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New York And employed by H.S.B.I & 1. Co.

Hartford, CrT have inspected these iters described in this Data Report on

, and state that to the

.. est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance *ith the ASME Code,Section III, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.

Date

~

~/

Signed Commissons

~ )SZ7

~

(NaV ad. (wic. lEndarerneaml) amd a~ta-w prow.

and mi.

Design spec Cover i

(- =

tw pplicable)

I j

w

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cerficate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and aodress of r-urchnaerj
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 iname and address) 5.700 PSI N/A I

UV.f

. --.. l (C R N I (y-s b uil t Lmar.spec og*

(drawing nr) 5 AMEM Code.Section III. Division 1:

(marl. spec. no.)

4 '4

  • '71 1'

N/A 1,

V__________________f_______

(edition)

(addenda date)

(class)

(Code Case no.;

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance National Serial Number Board No.

In Numerical Order (1)

HT: 54682 S/N 1 N/A (2)

HT: 54682 S/N 2 N/A (3)

HT: 54682 S/N 3 N/A (4)

HT: 54682 S/N 4 N/A (5)

HT: 54682 S/N 5 N/A (6)

HT: 54682 SIN 6 N/A (7).

HT: 54682 S/N 8 N/A (8)

HT: 54682 S/N 9 N/A (9)

(10)

(11)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

10. Design pressure 1250 psi.

Temp.

575 Part or Appurtenance National Serial Number Board No.

In Numerical Order (21).

(27)

.(28)

(29) 130)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

"*F. Hydro. test pressure N/A At temp. "F (when appi.cable)

"Supplemental Information in the form of lists, sketches, or drawings may be used provided (1) size s11 'A x 1, (2) Information In Items 2 and 3 on this Data Report Is Included an each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(12MH)

This $orm (E00040) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.

Reiprnt (71 t)

4. l ype:

2001 I

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Sedal Nos.

HT: 54682 S/N 1 through SIN 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)

N/A (when applicablel P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N2607 Pilot Poppet Expires Atwood & Morrill Co., Inc.

(NPT Carohcat. Hakiew Signed 9o CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York Arnd employea oy Hartford, CT have inspected these Items described in this Data Report on

/

, and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accord ýnc %with the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date (Nn d

-in Enoame*

s an st o

.adn.1 Signed iAnse Upector)

Reg. no.

Reg. no.

N/A N/A Date 1'lýe Name 6-13-04 a

6-13-04

,//

(authoried repreenta=v)

U 4- 0 1 9I 1e 1- ^

Commissions At)'J"?j1-V 7*9,

,,0

-N*afl Bd. (mlec. Endersermnft*) *Rd Stte -r P-. and -1.

162AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name 76A9 Salem Blvd, Berwi Address Date Sheet Unit 04/25/2002 of ONE ECO 179460, PCWO 345125 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp None ck, PA 18603 Authorization No.

N/A Expiration Date N/A

4. Identification of System REACTOR VESSEL AND AUXILIARIES SYSTEM 162A CLASS 2
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, Winter 72
Addenda, N-411 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PIPE SUPPORT BECHTEL N/A N/A SPDCB112-1982 REPLACED NO H2003 PACIFIC 299NA SPDCB112 MECH SNUBBER SCIFIC23599 N/A 1981 REPLACED N/A SCIENTIFIC H2003 PIPE SUPPORT BECHTEL N/A N/A SPDCB112-1982 REPLACED NO H2014 PACIFIC SPDCB112 MECH SNUBBER SCIFIC 13942 N/A H201 1981 REPLACED N/A SCIENTIFIC H2014

7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
8. Tests Conducted:

Hydrostatic E

Pneumatic El Nominal Operating Pressure El Other E Pressure N/A psi Test Temp.

N/A

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/ in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant (12/82)

FORM NIS-2 (Back)

9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed

/A,, -//,a-Date 2.-0._

/2.-

,20

__-L-Owner rowners Desine Tide Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have nspected the comiginents described in this Owner's Report during the period

-0 2-I to

/'3-n:<-

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________C mmissions NIF7c/80 A.NB:ý'.14.S 04 Z W4 lnspectorifSignature National Board, State, Province, and Endorsements Date J1EA' 107 20O2.

164AI FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name Unit ONE ECO 179459, PCWO 345105 Repair Orgarization P.O. No., Job No., etc.

Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.

Expiration Date

4. Identification of System REACTOR RECIRCULATION SYSTEM 164A CLASS I
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, Winter 72
Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Code Case
7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
8. Tests Conducted:

Hydrostatic F

Pneumatic F

Nominal Operating Pressure 1:]

Other E Pressure N/A psi Test Temp.

N/A

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant Date Sheet 04/25/2002 1

of 1

N/A N/A ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PIPE SUPPORT BECHTEL N/A N/A SPDCA120-1982 REPLACED NO H2006 PACIFIC 23573 N/A SPDCA120-1981 REPLACED N/A MECH SNUBBER SCIENTIFIC H2006 (12/82)

II-FORM NIS-2 (Back)

9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Addenda 1" & smaller Nuclear Class I piping designed in accordance with the rules of Nuclear Class 2 DiDina per ASME 111, 1974 Edition, Summer 1975 Addenda, paragraph NB-3630.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date

ý

/ 2--,

20 ) L-Sid Ownr io wer's Dsi

. Title Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the co*ponents described in this Owner's Report during the period I

- Z

- /)

/

to 0

1

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ommissions NZ? 77 90AN P?

NS J

Z-0 4 Inspector'VIignature National Board, State, Province, and Endorsements Date "TvtvL 17

2002,

164AII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 769 Salem Blvd, Berwick, PA 18603 Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Address PPL Susquehanna, LLC Name ECO 179459, PCWO 345109 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.

Expiration Date

4. Identification of System REACTOR RECIRCULATION SYSTEM 164A CLASS II
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, Winter 72
Addenda, N-411 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Code Case
7. Description of Work REMOVE SNUBBER / NO REPLACEMENT
8. Tests Conducted:

Hydrostatic E Pneumatic 0

Nominal Operating Pressure E

Other E Pressure N/A psi Test Temp.

N/A

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant 04/25/2002 Date Sheet Unit 1

of 1

ONE N/A N/A ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

PIPE SUPPORT BECHTEL N/A N/A SPDCB1 12-1982 REPLACED NO H2094 MECH SNUBBER PACIFIC SPDCB112-1981 REPLACED N/A SCIENTIFIC 22861 N/A H2094 (12/82)

FORM NIS-2 (Back)

9. Remarks Applicable Construction Code: ASME III 1971 Edition thru Winter 1972 Ad. Code Case N-411 CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date 2-

/2Z-

,20 UL Owtr or Owner's oTite Siiv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND hav Jnsped the components described in this Owner's Report during the period 7

?* -. (21 to

-V ->--

t.S

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____________Commissions N8879*O8 A,...

/:

1S PA ZZO nspe Signature National Board, State, Province, and Endorsements Date Jlui 17 2002.

1Th

164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, P Address Date Sheet 05/25/2002 1

of Unit ONE MODIFICATIONS: 179459, 391402, & 391467 WORK ORDERS: 345105, 391433, & 391471 Repair Organization P.O. No. Job No., etc.

Type Code Symbol Stamp None A 18603 Authorization No.

N_

Expiration Date N

I/A

/A

4. Identification of System REACT I OR RECIRCULA I ION SYSTEM 164D CLASS 2
5. (a) Applicable Construction Code ASME Section III 19 71
Edition, Winter 72
Addenda, N-411 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

1) PIPE SUPPORT BECHTEL N/A N/A SPDCB106-1982 REPLACED NO H2022 PACIFIC SPDCB106
2) MECH SNUBBER SCIENTIFIC 24388 N/A H2022 1982 REPLACED N/A
3) SMALL PIPE BECHTEL N/A N/A SPDCB106-6 1982 REPLACED YES
4)

SMALL PIPE PPL N/A N/A SPDCB106-6 2002 REPLACEMENT NO

5) SMALL PIPE BECHTEL N/A N/A SPDCB108-3 1982 REPLACED YES
6)

SMALL PIPE PPL N/A N/A SPDCB108-3 2002 REPLACEMENT NO

7) SMALL PIPE BECHTEL N/A N/A SPDCB121-4 1982 REPLACED YES
7. Description of Work
8. Tests Conducted:

Permanent removal of snubber support, and replaced piping do to socket weld UT exam failures.

Hydrostatic F]

Pneumatic Other E Pressure E-Nominal Operating Pressure N/A psi Test Temp.

N/A

'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant E-(12/82)

FORM NIS-2 (Back)

9. Remarks CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date

,2001 O Owner's Osig/4e, Title "upv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND

-have inspected the gomponents described in this Owner's Report during the period U

- () --

I to

-.7- 0--

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

£,4)A, ý

'/?* L__*,1/4?

Commissions Ve'7280 A &.r.

AIS PA ZZO4 Inspector',ig nature National Board, State, Province, and Endorsements Date Up Z"

2 0 2.2-

164DII FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name 769 Salem Blvd, Berwick, PA 18603 Address Susquehanna Steam Electric Station Name Date Sheet Unit 05/25/2002 2

of 2

ONE 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name MODIFICATIONS: 179459, 391402, & 391467 WORK ORDERS: 345105, 391433, & 391471 Repair Organization P.O. No., Job No, etc.

Type Code Symbol Stamp None 769 Salem Blvd, Berwick, PA 18603 Address Authorization No.

Expiration Date

4. Indentification of System
5. (a) Applicable Construction Code III 19 71
Edition, thru W'72 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, N-411 Code Case
1. Owner
2. Plant N/A N/A ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

8)

SMALL PIPE PPL N/A N/A SPDCB121-4 2002 REPLACEMENT NO

183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
4. Identification of System Date Sheet Unit 4/25/2002 1

of 3

One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A 183A, Main Steam; Class 1

5. (a) Applicable Construction Code III 19 71
Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, 1535-2 Code Case
7. Description of Work
8. Ti Improve seating characteritics and maintainability of MSIVs ests Conducted:

Hydrostatic El Pneumatic E]

Nominal Operating Pressure nX SE-100-002/SE-000-017 Other n

Pressure 975 psi Test Temp.

521

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/22 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No) 26" MSIV Atwood & Morrill 5-221 NA HV141FO28A 1974 Replaced Yes 26" MSIV Atwood & Morrill 5-221 NA HV141F028A 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028A 2001 Replacement No nut assemblies)

Poppet Atwood & Morrill 245951-3 NA HV141F028A 2001 Replacement Yes Bonnet Cover Atwood & Morrill H3391-1 NA HV141F028A 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-1 NA HV141FO28A 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28A 2001 Replacement No (12/82)

1t -~

FORM NIS-2 (Back)

9. Remarks Installation work performed by Continental Field Systems, Inc. under their National Board NR Program.

National Board Forms NR-1 and ASME Forms N-2 are attached.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair/Replacement conforms to the rules of the ASME Code,Section XI.

repair or repiacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Signed Date 26

-20 02-er w gnee. TitUe Supv. - Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the perod Z - z Is-o to

(.o -.

4 - ) Z

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.&XZ1 4 S

.I

-/-

=--'J=*#.W Commissions NI?798OA T.Z_..,NS PA0 Z-0.4 Inspector's S/

ature National Board, Slate, Province, and Endorsements Date u Nh tC Z'

200_

183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner PPL Susquehanna, LLC Namre Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Namre 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address
4. Identification of System Date Sheet Unit 4/25/2002 2

of 3

One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.0- No., Job No., etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A 183A, Main Steam; Class 1

5. (a) Applicable Construction Code i11 19 71
Edition, thru S' 71 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, 1535-2 Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No.

Other Identification Year Built

Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No) 26" MSIV Atwood & Morrill 6-221 NA HV141FO28B 1974 Replaced Yes 26" MSIV Atwood & Morrill 6-221 NA HV141FO28B 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028B 2001 Replacement No nut assemblies)

Poppet Welding 245951-1 NA HV141FO28B 2001 Replacement Yes Services Inc.

Bonnet Cover Atwood & Morrill H3391-4 NA HV141FO28B 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-4 NA HV141F028B 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28B 2001 Replacement No 26" MSIV Atwood & Morrill 7-221 NA HV141F028C 1974 Replaced Yes 26" MSIV Atwood & Morrill 7-221 NA HV141F028C 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141 F028C 2001 Replacement No nut assemblies)

Poppet Welding 245951-2 NA HV141 F028C 2001 Replacement Yes Services Inc.

2. Plant Code Case

183A-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Owner PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101

2. Plant Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date 4/25/2002 Sheet 3

of 3

Unit One PCWO 345898, 345911, 345920, 345927 DCP 316333, 316334, 316335, 316336 Repair Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A

4. Identification of System 183A, Main Steam; Class 1
5. (a) Applicable Construction Code III 19 71
Edition, thru S' 71
Addenda, 1535-2 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Bonnet Cover Atwood & Morrill H3391-6 NA HV141FO28C 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-6 NA HV141FO28C 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141F028C 2001 Replacement No 26" MSIV Atwood & Morrill 8-221 NA HV141FO28D 1974 Replaced Yes 26" MSIV Atwood & Morrill 8-221 NA HV141FO28D 1974 Repaired Yes Super Bolts ( torque Atwood & Morrill N/A NA HV141F028D 2001 Replacement No nut assemblies)

Poppet Atwood & Morrill 245951-6 NA HV141F028D 2001 Replacement Yes Bonnet Cover Atwood & Morrill H3391-2 NA HV141FO28D 2001 Replacement Yes Pilot Poppet Atwood & Morrill 54682-2 NA HV141FO28D 2001 Replacement Yes Body/Bonnet Stud Atwood & Morrill NA NA HV141FO28D 2001 Replacement No

FORM NR-1 REPORT OF REPAIR [ý MODIFICATION 0]

OR REPLACEMENT []

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah, GA 31405 (address)
2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA Salem Twp, PA
4. System 1-83 HV141FO28A Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

9 10 11 12_

5. b: Items Installed During Replacement Activities e Attache d Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/

Code Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section XI applicable for inservice inspection:

1989 N/A N/A (edition)

(addenda)

(Code Cases(s))

7. ASME Code Section XI used for repairs, modifications, or replacements:

19.8&9 NIA N4 A/

(edition)

(addenda)

(Code Cases(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 S 71 N/A (edition)

(addenda)

(Code Cases(s))

9. Designresponsibilities:

Atwood & Mnrril fn

10. Tests conducted: hydrostatic [E pneumatic El design pressure El pressurejNLA. psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

(e.pDescniptionlofsoseork:

Se Ata h d

(use of property identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks: See attached manufacturer's data report V

CERTIFICATE OF COMPUANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-R6 to use the "NR" stamp expires 5/2i 2001 NR Certificate Holder Continental Field Systems.

Inc Date 641&

9002 Signed __Iliin1)

.I 0

U tv (',-inirrl MnlnnaPr CERTIFICATE OF INSPECTION I, WIL.IAM 2'

'i2 60* r_

i holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of

?NN Yt. V4,M/4 and employed by h-Actvgy Mu 9L r

I4XyR. #tyCE-Commm' of CFoH,'IroAI IZ E have inspected the repair, modification or replacement described in this report on 4

  • 1 00Z.

and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

DateTNek z+.ZA LUOZ Signed 4

4.a?,'7?

V 07.iZ CommissionsN8R7 OA3 A.",/1Nr PA 2..04 (inspector),1 (National Board (ind. endorsements), jurisdiction, and no.)

See Attached

  • ork:
11. Description of v (title.)..

(authorized representative)

Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A Items Which Required Repair, Modification, or Replacement Activities Identification Items Installed During Replacement Activities Identification Report of Repair / Replacement Job Number 3218 Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced A&M 3

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Bonnet Replaced A&M I

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Pilot Poppet Replaced A&M I

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I

I of 2

Form NR-1 Attachment Report c Worked Performed by Continental Field Systems, Inc.

C 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028A

6. ASME Code Section XI applicable for inservice inspection: 1989 (edition)
7. ASME Code Section X] used for repairs, modifications, or replacements:1989 (edition)
8. Construction Code used for repairs, modifications, or replacements: 1971 (edition) ff Repair / Replacement Job Number 3218 N/A NI (addenda)

(C N/A (addenda)

Summer 71 (addenda)

A ode Case(s))

N/A (Code Case(s))

I Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (iname and address of Purchaserl
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:
  • 32162-409-D Rev. 1 SA 105 GR II 81,600 PSI N/A 2001 (dra'wig no.)

(mati. spec. no.)

(tensile strength)

(CRN)

(year built

5. ASME Code,Section III, Division 1:

1971 S71 1

N/A (edition)

(addenda datas)C0 so no.--,

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Nom. Thickness (in.)

5.312 Min. design thickness (in.)

5.094 Dia. I1 (ft & in.)

N/A Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

-(1)

HT: H3391 S/N 1 (2)

HT: H3391 S/N 2 (3)

HT: H3391 S/N 3 (4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(14)

(17)

(1 8)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

10. Design pressure In Numerical Order N/A N/A N/A (26)

(27)

,(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(381

+

_________________________ 4 I.

1-1.4ffi2.

I t

I i

I1

.4.

4 1250 psi. Temp.

575 (39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

"F. Hydro. test pressure N/A (when applicable)

At temp. F

"*Supplemental information In the form of lists, sketches, or drawings may be used provided (1) size Is 8 'A x Il. 12) Information in items 2 and 3 an this Data Report is included on each sheet is numbered and the number of sheets is recorded at the top of this form.

(12188)

This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300. Fairfield, NJ 07007-2300.

Reprint (711)

I I

I I

I I

i i

i I

nI umgll;leu 1

At temp. "F i

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 1 through S/N 3 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A (when applicable)

N/A (when applicable)

P.E. State N/A P.E. State N/A CERTIFICATE OF COMW We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Date N2607 Expires Name Atwood & Morrill Co., Inc.

(NPT Cenificat, Holder) 6-13-04 P

Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.

of Hartford, CT have inspected these items described in this Data Report on

, and state that to the R~est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accodance with the ASME Code, Section Divisibn 1. Each part listed has been authorized for stamping on the date shown above.

i signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this insRp tioC io Date Signedal Commissionst=

end (aWoflzed imaput)

(Narl S&. (inci E idE nmalh) and state of prow. and no.]

Reg. no.

Reg. no.

N/A N/A Cover L

(waud;zed mrelsmertab-)

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address or NPT Certificate Holder)
2. Manufactured for Pennsylvania Power & Light - Berwick, PA 18603 (name and address of Purcnasaerj
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179
4. Type:

Iname and Bursess}

  • ^A'/(Q 120A dS7nn PRI N/A 2001

"¶jZ4I*L-oi3,-1,

ev o¶t'VA4. I=,lp%,,

(drawing n. ).

'..i-Is stne-rh.

(CCRN)

(year built)

(dr-aving no.)

.a i

lmari spec. no.)

-110-7"1 S'71 1-N/A S. ASM. Code, iec on (edibon)

(addenda data)

(class)

(Code Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& in.)

N/A

9. When applicable, Certiricate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number

- (1)

HT: 54682 E (2)

HT: 54682,"

(3)

HT: 54682 (4)

HT: 54682 E (5)

HT: 54682 (6)

HT: 54682,

(7).

HT:54682, (8)

HT: 54682 (9)

(10)

(11)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

10. Design pressure SIN 1 National Board No.

In Numerical Order N/A S/N 2 N/A S/N 3 N/A IN 4 N/A 3/N 5 N/A S/N 6 N/A 3/N 8 N/A S/N 9 N/A 1250 psi. Temp.

575 Part or Appurtenance Serial Number (26).

(27)

-(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

National Board No.

In Numerical Order (39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

"F.

Hydro. test pressure N/A At temp. "F

-Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 'A x 11, (2) Information in items 2 and 3 on this Data Report is included on each sheet Is numbered and the number of sheets is recorded at the top of this form.

(12J88)

This form (EO0040) may be obtained from th. Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007-2300.

Reprint (71 Sl)

(when applicble) i I

I

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)

N/A (when applicable)

P.E. State N/A P.E. State N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section I1l, Division 1.

NPT Certificate of Authorization No.

N2607 Expires Pilot Poppet 6-13-04

-a Atwood & Morrill Co., Inc.

(NPT Cerbtlcate HoNder)

Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.l & 1. Co..

of Hartford, CT have inspected these items described in this Data Report on

, and state that to the

,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordd ncefwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Sge Commissions

"!pd.nn--

=d iseM

-(Nafl Bd. (fnd. Endomemants) and out@ or pm.,. and n.

Date Llý0 Name New York (authorized rerewbabmt)

H.S.B.I I.

Co.

u-U.r INt-UtIIIVI.

I lUlV UnIL Y FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

1. Manufactured and certified by Atwood & Morri? Co., Inc. 285 Canal Street Salem, MA 01970 (name and adoress o NPT Certfkcate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name an addMres of PurChaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown. PA 18101-1179 (name and address)
4. Type:
  • 32467-622-D Rev.7 I

t%0m"nq no.I

5. ASME Code,Section III, Division 1:
  • SA 105 GR II (malnr apc nS.p.

1971 77+100 PSI S71 (addena. "toj

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A (no.)

Revision N/A Data N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) "Dwg. prepared by A&M. This certification meets the required information of ASME Section I11 1971 Edition summer 1971 addenda

8. Nom. Thickness (in.)

7.312 Min. design thickness (in.)

5.49

. Ola. ID (ft & in.)

N/A

'Length overall (Rt& in.)

N/A

9. When applicable, Certificate Holders' Data Reports we attached for each item of this report Pad or Appurtenance Serial Number (1)

(2)

(3)

(4)

(5)

(6)

(7)

(a)

(Q)

(10)

(11)

(12)

(13)

J(14)

(IS)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(P)

(24)

(25)

HT: 245951 S/N 3

10. Design pressure National Board No.

In Numerical Order N/A 1250 paL Temp.

Part or Appurtenance National Serial Number.

Board No.

In Numerical Order (25)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(36)

(38)

(36)

(40)

(41)

(42)

(43)

(44)

(45)

(48),_________

(47)

(48)

(49)

(50) 575

'F.

Hydra. test pressure N/A towhen me)

At temp. °F "SupplementlW information in the form of Isle. sketches, of drawkngs m*a be used provided (II sie Is I Ya 11. (2 information In hItms 2 and 3 on dtis Data ReporitIs Included as each shoot is numbsen and MIe number of shouta Is racorded at t. top of MWI fasr;.

Thisform iE0O40) may be obtalned from the Orcer Dept.. ASME. 22 Law Drlve. 8= Z=. FaMold. KJ 07007-2=

P9. 1 of 2 N/A 1

- SA105 R 1 T7 00 SI NA 2041 N/A

!oidecam

,a&) 58.1 C

Pq. 1 of 2

ýýwqlfwu Lu. r, I -

Expires On: V??

  • 3nl t*CfI

. -400")

11211111

rtjn* llvrurl¥1v* I IUIv UIrLT Repuint 17191)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 245951 S/N 3 through N/A CERTIFICATION OF DESIGN Design specifications certified by Design report

  • certified by

'N/A (when~ apocabie)

N/A (Whel applicable)

P.E.

State P.E.

State N(A N/A CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section 1II, Division 1.

Reg. no.

Reg. no.

N/A N/A

.Poppet NPT Certificate of Authorization No.

Date N2607 Name Expires Atwood & Morrill Co.. Inc.

(NPT Cev~fuit HOWe) 6-13-04 Signed CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and th State or Province of And employed by H.S.B.I & I. Co.

of Hartford, CT have inspected these items described in this Data Report on 47/

,/0/

and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code. Section

111, ODvision 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shill be liable In any manner for any personal Injury or property damage or loss of any kdnd arising from or connected with this Inspection.

Commissions 4j)>'ý g

Ai.1

(~n at d. P nd. Endrsfmvnf) and $af at pm. sad ro.)

I.

New York Date Signed ii*

-ýwwl ICU &U. : -.,

tLxpires On: 1??

FORM NR-1 REPORT OF REPAIR I MODIFICATION ED OR REPLACEMENT [X]

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Sqystems, Tnc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah, GA 31405 (address)
2. Owner PPT.

T.I.C (name) 2 North Ninth Street.

Allentown, PA 18101 (address)

3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick, PA
Salem, Twp, PA 4.System 1-83 HV141FO28B Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 8

5. b: Items Installed During Replacement Activities q*

A r t nrh Pd Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat'l Bd.

Jurisd Other Year Name/

Edition/ rCode Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section )G applicable for inservice inspection: 1989 N/A N/A (edition)

(addenda)

(Code Cases(s))

7. ASME Code Section )a used for repairs, modifications, or replacements:

19 89 N1 iA N/A S(edition)

(addenda)

(Code Cases(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 S 71 N/A (edition)

(addenda)

(Code Ca~ses(s))

9. Design responsibilities:

Atwood & MorrIl Co.

10. Tests conducted: hydrostatic D] pneumatic []

design pressure D]

pressureNA.__ psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

11. Descriotion of work:

5 i c At- -

I-, A (use of properly identified additional sheet(s) or sketch(es) is acceptable)

12. Remarks:_

See attached manufacturer's data report i--

CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-86 to use the "NR" stamp expires 5/25 2003 NRCertificate Holder Continental Field Systejs, Inc Date 6/18 2002 Signed Quality Control Manager CERTIFICATE OF INSPECTION I,

$ilA,&.

17

'-i 0

, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of PENN S Yo.

V4 N14 and employed by C~crory MuruAL tMsur4mce" Cea"*,w jy

-of JoN70W oS

"*?q have inspected the repair, modification or replacement described in this report on Z00, 2OO-and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XG of the ASME Code and the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of kind arising from or connected with this inspection Date obuNer Z +

4 2P-,

SigneM *

.*-4/*,P r

Commissions A/8798DA.*.Z 5PA4ZO (inspect (National Board (inc. endorsements), t-risdition, and no.)

(title) l-.......

(a-uthorized representative)

I Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B Report of Repair / Replacement Job Number 3218 Items Installed During Replacement Activities Identification Installed/

MFG.

Mfg. Serial Replaced Name No.

Replaced WSI I

Replaced A&M 4

Replaced A&M 4

Replaced A&M NU-01017 Nat'l Bd. No.

N/A N/A N/A N/A Jurisd. No.

N/A N/A N/A N/A Other Year Built Name/

Section/

Division N/A 2001 III NB N/A 1

2001 111 NB N/A 201IIN N/A N/A 2001 2002 III NB Ill NB Construction Code Edition/

Code Code Addenda Case(s)

Class 71 Ed. S71 A N/A I

71E.S71 A 71 Ed. S71 A N/A N/A I

L _____

.1 _______

L ____

I ______

I ______

1.

I.

I ______

1 of 2 "I

Item Poppet Bonnet Pilot Poppet Super Nuts 71 Ed. S71 A N/A I

Form NR-1 Attachment Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.

Job Number 3218

(

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 'h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028B

6. ASME Code Section X1 applicable for inservice inspection: 1989 N/A N/A (edition)

(addenda)

(Code Case(s))

7. ASME Code Section XI used for repairs, modifications, or replacements:]1989 N/A N/A (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 Summer 71 1

(edition)

(addenda)

Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2

1.

Manufactured and certified by

2.

Manufactured for

3.

Location of installation Weldina Services. Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address of NPT Certificale Holder)

Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)

PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name anadri (oess)

4.

Type:

A& M DO SA 105 Gr.

70.0 Ksi" N/A 2001 32467-622 R/7 (drawing no.)

(mat'l. spec. no.)

(tensile strength)

(CRN)

(year built)

5.

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6.

Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7.

Remarks:

21" MSIV Valve Poppet SA 105 Gr.lI with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 forSA 105 Gr. II "Heat #s 00-21-01, 00-21-05,00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21

8.

Nom. Thickness (in.)

NIA Min. design thickness (in.)

NIA Dia. ID (f

9.

When applicable, Certificate Holder's Data Reports are attached for each Item of this report:

Part or Appurtenance Serial Number 9'951-- 1-1 24595 94dSq1I-2 24595-2.

')AO1

-

24*5951-7

')AO4

.A

  • 4595ts -9 45951 245951-

1

.4.

+

+

4

'I

10.

Design pressure N/A National National Board No.

In Numerical Order psi.

Temp, (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38) 0in.)

21"0,.

SO Part or Appurtenance Serial Number 4

I

_________________________________ 4.

National Board No.

In Numerical Order (40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

N/A

  • F Hydro. test pressure NIA at temp. 'F (when applicable)
  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 81 x 11, (2) information in items 2 and 3 on this Data Report is included or each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00040) may be obtained from the Order Dept.. ASME 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

Reprint (7191) 1VJbrarysvr~quahity_a %Project FiestAtwood & MornA2001031140 )Oct 2001)W2-31140.doc 1(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 24595114 245951-5 245951-7 I

Length overall (ft& in.)

31'

'*ac.(:* 1..4

FORM N-2 (Back - Page 2 of 2 )

Certificate Holders Serial Nos.

Ht # 245951 through 1,2.4.5,7,8,9 CERTIFICATION OF DE Design Specifications certified by Design Report" certified by Boyd P. Brooks (when applicable)

Herbert Cook (when applicable)

SIGN P.E. State CA Reg. NoA 13655 P.E. State MA Reg. No..

10981 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N-2873 x ires Nove 13,2004 Date 12-10-01 Name

-Welding Services Inc.

Sig G:7u.

eP (NPT Certificate Holder) authorized represenlalive)

//U CERTIFICATE OF INSPECTION.

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford,. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code,Section III.

Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspectorIor his employeE shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wi this ins ion.

Date 12-10-01 Signed Commissions NB # 11465 ABN, GA # 393 (Auth i or)

[ Nall. Bd. (inc. Endorsements) and state or pray. and no.)

Wibrary_svrquaity_a VProjecf FieslAtwood & Morrillt2001l31140 )Oct 2001)W2-31140.doc F

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970
2. Manufactured for Pennsylvania.Power & Light Berwick, PA 18603 tnc.

l l Iname anu au wress v**=*

3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and addressl A

Ttnm



Rv I

SA 105 GR II

a.
  • 1ec.6 Rev.

_1n

  • 1,mt-~r
  • mi (m7ar1 ec. no.)

(drawing no.)

5. ASME Code,Section III, Division 1:
6. Fabricated in accordance with Const. Spec. (Div. 2 only)

(71 1971na S71 a

1iai'-

'N/A 1

Revision N/A N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Noa. Thickness (in.)

5.312 Min. design thickness (in.)

5.094 Dia. ID (ft & In.)

N/A

9. When applicable. Certificate Holders' Data Reports are attached for each item of this report:

=art or Appurtenance Serial Number I-T" H*Q1 S*/N 4 National Board No; In Numerical Order N/A HT: H3391 S/N 5 N/A HT: H3391 S/N 6 N/A I;

  • I.

.1.

Part or Appurtenance Serial Number (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

-(35)

(36)

(37)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

__________________________ 4-

__________________________ +

__________________________ +

__________________________ 1

_________________________ +

_________________________ 4 t

4 I

Length overall (ft& In.)

N/A National Board No.

In Numerical Order

10. Design pressure 1250 psi.

Temp.

575 "F. Hydro. test pressure "Supplemental Information In the form of lists, sketches, or drawings may be used provided (1) size is 8 V. x 11.12) Information In items 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

This form 1E00040) may be obtained from the Order Dept., ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300.

Pg.1 of 2 77.900 PSI N/A 2001 J

P (1)

(2)

.(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(1)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A (when appliicable)

At temp. "F (name and address of NPT Certificate Molder)

L-

. Typ

(

(class)

(addenda date)

(1211118)

Reprint ('71 91)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by N/A (when applicable)

Design report' certified by N/A (when applicable)

P.E. State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made In this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Name N2607 Expires Atwood & Morrill Co., Inc.

(NPT Crtfcate

,akld)

Signed (au-vooze.l representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.

of my Hartford, CT have inspcted these items described in this Data Report on and state that to the

.,st of my knowledge and belief, the Certificate'Holder has fabricated these parts or appurtenances in accordance-with the ASME Code, Section

,n, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection.

Date 47 Signed

.Commissions Reg. no.

Reg. no.

N/A N/A Date Cover kM Vrnrle 6-13-04

.. =

(audkorizd I*s*tr

[NaVl Bd. (incl. EndiosrseentS} =NW star-or prov. and ne.I

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Cartficate Holder)

2. Manufactured for Pennsylvania Power & Light - Berwick, PA.18603 (name and address or Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name. and address)

A

-r,.,.

'A1'&J



fl

,yi.

(drawing no.)

5. ASME Code,Section III, Division 1:

RA 47Q-:*f'4.

1Mrl7. Spec. no.)

(edition)

6. Fabricated in accordance with Const. Spec. (Div. 2 only) 85.700 PSI N/A 2001 e:

j

  • 3246261.--3l

~- C/I R

v. 0, 85i

,700 PSI-S..

. *i,*

J.

t h),t, (C, RN) iywar built)

(t iltng en 1971nd dS71(les N/A (no.)

1 Revision N/A Date N/A N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (In.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A Length overall (ft& in.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number HT: 54682 S/N 1 National Board No.

In Numerical Order N/A HT: 54682 SIN 2 N/A HT: 54682 SIN 3 N/A HT: 54682 S/N 4 N/A HT: 54682 S/N 5 N/A HT: 54682 S/N 6 N/A HT: 54682 S/ON 8 N/A HT: 54682 S/N 91/

I-Part or Appurtenance Serial Number (28)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37) t*R\\

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50) 1-I

  • 1
  • 1

_______________________ '1*

_________________________ 4 I.

I I

I I

4

__________________________ 4.

__________________________ 4.

__________________________ +

National Board No.

In Numerical Order

10. Design pressure 1250 psi.

Temp.

575

"*F. Hydro. test pressure

-Supplemental Information In the form of lists, sketches, or drawings may be used provided Ill size Is 0 'A x 11. (2) Information In Items 2 and 3 on this Data Report 1s Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

This form (EO0040) may be obtained from the. Order Oept., ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.

Pg. I of 2 (1)

(2)

(3)

-0)

(5)

(6)

(7).

(8)

(9)

(10)

(11)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A

  • when applicable)

At temp. *F

. Tjp (addenda date)

( class)

(1218)

Reprin~t (TO II1I

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report* certified by N/A (when applicable)

N/A (when appllcablel P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are cdrrect and that this (these) conforms to the rules of construction of the ASME Code, Section I11, Division 1.

NPT Certificate of Authorization No.

N2607 Expires Pilot Poppet 6-13-04 a

Atwood & Morrill Co., Inc.

(NPT Crtbfcate Holder)

Signed

/p14zt&

(authorized representaibve)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and'Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.

of Hartford, CT have Inspected these Items described in this Data Report on

,7,

/

. and state that to the

,st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accord rnce with the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date Commissions

  • /)Ž,7e E 1)-'n'

[Nafn 6d. (mot. Enclosenemfft) and tauto Or pic. and n.

Reg. no.

Reg. no.

N/A N/A Date Name New York

- 11.11 - --

w Signed

ýý&d

rspec"

FORM NR-1 REPORT OF REPAIR fl MODIFICATION El OR REPLACEMENT []

TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1.

Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

93 West'gatP Blvd-Savannah, GA 31405 (address) 2.Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)

3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles North of Berwick. PA Salem.Twp, PA
4. System 1-83 HV141F028C Main Steam
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3 4

5 6

7 9

10

5. b: Items Installed During Replacement Activities See At taizhed Identification Construction Code Type of Installed or.

Mfg.

Mfg Natl Bd.

Jurisd Other Year Name/

Edition/

Code Cd Item Replaced Name Serial No.

No.

No Built Section/

Addenda Iaes ls 5a Item No.

Division

6. ASME Code Section XI applicable for inservice inspection:

1989 L.N/A N/A (edition)

(addenda)

(Code Cases(s))

7. ASME Code Section XI used for repairs, modifications, or replacements:

1989 N/A N/A (edition)

(addenda)

(Code CaseS(s))

8. Construction Code used for repairs, modifications, or replacements:

A{L.N/A N/A (cditio (addenda)

(Code Cases(s))

9. Design responsibilities:

Atwood & Morrill Co.

10. Tests conducted: hydrostatic lI pneumatic L] design pressure []

pressureN4A_

psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1"055 Crupper Ave., Columbus, OH 43229 Rev. 8 I

T 1

1 1

1 1

1

-t 4

I 1

1 4

4 4

4

+

+

4 I

4-1 4

4 4-4 4

+

+

I 4

4 4

4 4

4 4

4

4.

4-L 4

1 1

4 4

-+

4 4

+/-

+

4 t

I t

4 4

4 4

4

+

+

4 4

4

+

4 4

4 4

4 4-4-

4 4

4 4

4 4

1 4

4 4-4-

4 I

T 4

4 4

4 4

4 4

4--

4 4

t 4

4 4

4 4

4

+

+

4

11. Description of work:

(use of properly identified additional sheet(s) or sketch(es) is acceptable) 12.Remarks:

See attached manufacturer's data report CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section X) of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

NR-82 to use the "NR" stamp expires 5 /25 2003 NR Certificate Holder Continenta Ield Syst P nc.

Date 61 90n Signed

.C-e)

Wm-lniyrat.

A2ae (authorized representative)

(title)

CERTIFICATE OF INSPECTION I, WILLIAM 'e '906 CTS holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of N*NSYL VAN4V/4 and employed by R~cmprj MuTLm.IA rsum Heir COA

,t74V of Z-0$ImcON.

leI have inspected the repair, modification or replacement described in this report on 4,

I

, Z 00 Z and state that to the best of my knowledge and belief, this repair, modification or r'eplacement activity has been completed in accordance with Section XI of the ASME Codgý and the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury property damage or loss of any kind arising from or connected with this inspection.

DateJ'V"'( Z4 O*O_ 1 Signed4,,J i

7el, r"

-- 7Tr-CommissionsUB79BOA.-t, JAM P*,

o4 (Inspector)*

(National Board (ind. endorsements), jur"idiction, and no.)

RPP AttnohPA

Report of Repair / Replacement Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C Items Which Required Repair, Modification, or Replacement Activities Identification No Type of Item Mfg. Name Mfg Serial Nat'l Bd.

Jurisdiction No.

No.

Job Number 3218 tAner Year Built Name/ Section/

Division Edition /

Addenda Construction Code Code Code Class Case(s)

Repair/

Replace 1

MSIV A&M 7-221 N/A N/A N/A 1974 ASME III/NB 1971/S71 1535-2 1

Repair 2

Items Installed During Replacement Activities Identification f 2 Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced WSI 2

N/A N/A N/A 2001 III NB 71 Ed. $71 A N/A I

Bonnet Replaced A&M 6

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Pilot Poppet Replaced A&M 6

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Super Nuts Replaced A&M NU-01017 N/A N/A N/A 2002 Ill NB 71 Ed. S71 A N/A I

Construction Code Form NR-I Attachment

Form NR-1 Attachment Worked Performed by Continental Field Systems 23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 1h St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028C

6. ASME Code Section Xl applicable for inservice inspection: 1989 (edition)
7. ASME Code Section X1 used for repairs, modifications, or replacements: 1989 (edition)
8. Construction Code used for repairs, modifications, or replacements:

1971 (edition)

Report of Repair / Replacement Job Number 3218 N/A N/

(addenda)

(C N/A (addenda)

Summer 71 (addenda)

A ode Case(s))

N/A (Code Case(s))

I Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and replace with new components from OEM as part of valve enhancement.
12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.

2 of 2

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2

1.

Manufactured and certified by

2.

Manufactured for

3.

Location of installation Welding Services, Inc. 2225 Skyland Court, Norcross GA, 30071 (name and address or NPT Caflitsolu Holder)

(name and address of NPT CereitScale HoMAer)

Atwood & Morril Co. 285 Canal Street. Salem, MA 01970 (name and address of Purchaser)

PPL Susquehanna Nuclear Power Plant. Berwick, PA. 18603 (name and address)

4.

Type:

A & M Dwg D-SA 105 Gr.11 70.0 Ksi N/A 2001 32467-622 R/7 (drawing no.)

(mall. spec. no.)

(tensile strength)

(CRN)

(year buill)

5.

ASME Code,Section III, Division 1:

1971 S 1971 1

N/A (edition)

(addenda dale)

(class)

(Code Case no.)

6.

Fabricated'in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date NIA (no.)

7.

Remarks:

21" MSIV Valve Poppet SA 105 Gr.II with SFA 5.13 Alloy 21 Stellite 21 Hardsurfacing. Heat# 245951 for SA 105 Gr. II Heat #s 00-21-01, 00-21-05.00-21-06,101001836, 01-0876 and 1210-N0832R125 for Stellite 21

8.

Nom. Thickness (in.)

N/A Min. design thickness (in.)

NIA

9.

When applicable, Certificate Holder's Data Reports are attached for each item of t" Dia. ID (ft &in.)

21-Nom.

Length overall (ft & in.)

31" 00 Part or Appurtenance Serial Number 245951-1 1-245951-2 245951-245951.-4 245951-5 245951-7 245951-8 245951-9 National Board No.

In Numerical Order Pad or Appurtenance Serial Number (28)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

_________________________________ 4.

+

_________________________________ +

+

_________________________________ 4

_________________________________ 4 4

I 4

_________________________________ 4 1.

National Board No.

In Numerical Order I

t.)

10. - Design pressure N/A psi.

Temp.

N/A (40)

(41)____________

(42)

(43)

(44)

(45)

(46)_______________

(47)

(48)

(49)

(50)

  • F Hydro. test pressure N/A (when applicable)
  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 1A x 11, (2) information in items 2 and 3 on this Data Report is included ori each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form, (12/88)

This form (E00040) may be obtained from the Order Dept., ASME 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300.

Reprint (7/91) lVibrary svrV.ualitya Ptroject FlestAtwood & MornlA2001L31140 )Oct 2001)W2-31140.doc (1)

ý,2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

  • 1'13'l (14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25) at temp. 'F (13)"w~

I I

FORM N-2 (Back - Page 2 of 2 Certificate Holder's Serial Nos.

HI # 245951 through 1,2.4,5,7,8,9 CERTIFICATION OF DESIGN Design Specifications certified by Boyd P. Brooks P.E. State CA Reg. No.1 13655 (when applicable)

Design Report* certified by Herbert Cook P.E. State MA Reg. No.,

10981 (when applicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) 21' MSIV Valve Poppets conform(s) to the rules for construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N-2873 x ires Nave r 13,2004 Date 12-10-01 Name Welding Services Inc.

Sig net-Lu (NPT Certificate Holder)

(authorized representative)

CERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Co.

of Hartford. CT have inspected these items described in this Data Report on December 10, 2001 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with ASME Code,Section III, Division 1. Each part listed. has been authorized for stamping on the-date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector or his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected i

is ins :ifon.

wo.I V

  • -\\

IA*

Date 12-10-01 Signed and slate or prov. and no.]

WLJbrary_svrlquality_alProjecf FiesrAtwood & Mor7*l200 131140 )Oct 2001)W2-31140.doc

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address or mri Certificate Holder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 iname and aootres of PurCnaser'
3. Location of installation Suscuehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and mddress)
4. Type:
  • 32162-409-D Rev. 1 (drawing no.)
5. ASME Code,Section III, Division 1:

SA 105 GR II (marL.eape no.)

1971 (edmon) 77.900 PSI Pens"l stength)

S71 (aodenaa oate)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date 7 Rno.4

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M PIN 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME

  • pr*inn III 1.(:71 Frlitinn imtmmpr 1971 addenda
8. Nom. Thickness (in.)

5.312 Min. design thickness (tn.)

5.094 Dia. ID (ft & in.)

N/A Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance National Serial Number Board No:

In Numerical Order (1)

HT: H3391 SIN 4 N/A (2)

HT: H3391 S/N 5 N/A l(3)

HT: H3391 S/N 6 N/A (4)

(5)

(6)

M (8)

(1)

(11)

(12)

(14)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Part or Appurtenance Serial Number (25)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

.(35)

(36)

(37)

-(38Y (39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

  • i.

4 4

I National Board No.

In Numerical Order

0. Design pressure 1250 psi.

Temp.

575

  • F. Hydro. test pressure "Supplemental Information In the form of lits, sketches, or drawings may be used provided (1) size Is 8 V, x 11, (2) Information In items 2 and 3 on this Data Report is Included on each sheet Is numbered and the number of sheets is recorded at the top of this form.

This form (E00040) may be obtained from the Order DepL. ASME. 22 Low Drive,. Box 2300. Fairfield, NJ 07007.2300.

Reprint (71 91)

Pg. 1 of 2 N/A 1

2001

tclass, (y-a Wtl N/A vaee SOC -. 9 (Code Case no.A N/A N/A (when applicable)

At temp. *F SA 105 GR 11 (Ives)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 SIN 4 through S/N 6 CERTIFICATION OF DESIGN Design specifications certified by Design report

  • certified by N/A (when applicable)

N/A (when applicable)

P.E. State N/A P.E. State N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code, Section II1, Division 1.

NPT Certificate of Authorization No.

Date Name N2607 Expires Atwood & Morrill Co., Inc.

(NPT Cef0lmiat Holder)

Signed

./:

(a-P represntative CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I& I. Co.

bf Hartford, CT have inspected these items described in this Data Report on

/.1

, and state that to the rst of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance-with the ASME Code, Section

.. Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date

//

ý7 l Signed

__Commissions VyJý5

,Ze.

Reg. no.

Reg. no.

N/A N/A Cover New York (authorized map="t 6-13-04

,1)

I I

/I.

[Natl ad. ('icl. Endo~rsernard and state or pmov. and no.l

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2 Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 inaame and address of NPT Certificate Holder)

2. Manufactured for Pennsylvania Power & Light
  • Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 iname and address) 5.700 PSI N/A 2001

-ma v

I.Ss v

W

  • f.HqA A7930 5q. 70 PSIV'*

(drawing no.)

5. ASME Code,Section III, Division 1:

(marl Spec7. no.)

-1074 A71 1.

N/A 1 ICoeI se

,0.

(edition)

(addenda date)

(class)

(Code Catso no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no)

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& in.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance Serial Number HT: 54682 S/N 1 National Board No.

In Numerical Order N/A HT: 54682 S/N 2 N/A HT: 54682 S/N 3 N/A HT: 54682 S/N 4 N/A HT: 54682 S/N 5 N/A HT: 54682 S/N 6 N/A HT: 54682 S/N 8 N/A HT: 54682 S/N 9 N/A Part or Appurtenance Serial Number (261 (27)

.(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

-4 (39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

National Board No.

In Numerical Order

0. Design pressure 1250 psi.

Temp.

575 "F. Hydro. test pressure "Supplemental Information In the form of lists, sketches. or drawings maybe used provided (I) size Is 111A x 11, (2) Information In itsms 2 and 3 on this Data Report Is Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(I21i/)

This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive. Box 2300, Fairfield, NJ. 07007.2300.

Reprint (7!91)

A

'r,*.

  • 13Aa

_C1'2 r

" ('I (1)

(2)

(3)

(4)

(5) 11(6)

(7).

(8)

(9)

(10)

(12)

(14)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A (when applicable)

At temp. "F i

,)p,=.

W

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A when appicabe)

N/A (when applicable)

P.E. State N/A P.E. State N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

Pilot Poppet NPT Certificate of Authorization No.

Date

/Name N2607 Expires Atwood & Morrill Co.. Inc.

(NPT Cartficate Heldwo 6-13-04 Signed A~a-(audtnized repreasenb.)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by H.S.B.I & I. Co.

of Hartford, CT have inspected these Items described in this Data Report on 4;7,,V7,,

/

, and state that to the est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordincerwith the ASME Code, Section

. Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date 4/47ige

ýPttonzed inpeot'

74-K1 Comm issions

,1X-5 e

70 e-'

(Nail Bd. rind. Endorazmerne) and slte or prov. and no.)

New York Name f

Signed

FORM NR-1 REPORT OF REPAIR EX MODIFICATION El OR REPLACEMENT TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by Continental Field Systems, Inc 3218 (name of NR certificate holder)

(P.O. no., job no., etc.)

23 Westgate Blvd.

Savannah, GA 31405 (address)
2. Owner PPL LLC (name) 2 North Ninth Street, Allentown, PA 18101 (address)
3. Name, address and identification of nuclear power plant Susquehanna Steam Electric 5 Miles NoEth of Berwick, PA SalemTwp.PA
4. System I -8 HV141FO2R8D Mainqteamrn
5. a: Items Which Required Repair, Modification, or Replacement Activities See Attached Identification Construction Code Activity Type of Mfg.

Mfg.

Nat'l Bd. Jurisd.

Other Year Name/

Edition/

Code Code Repair/

No Item Name Serial No.

No.

No.

Built Section/

Addenda Case(s)

Class Mod/

Division Replace 2

3

'4 5

6 7

8 9

10 11 12

5. b: Items Installed During Replacement Activities See Attached Identification Construction Code Type of Installed or.

Mfg.

Mfg Nat) Bd.

Jurisd Other Year Name/

Edition/

Code Code Item Replaced Name Serial No.

No.

No Built Section/

Addenda Case(s) Class 5a Item No.

Division

6. ASME Code Section XI applfcable for inservice inspection:

I 989 8

N A

N

/A (edition)

(addenda)

(Code Caes(s))

7. ASME Code Section XI used for repairs, modifications, or replacements:

1989 NXLA NIA (edition)

(addenda)

(Code Cas(s))

8. Construction Code used for repairs, modifications, or replacements:

1971 71S7I NIA (edition)

(addenda)

(Code Cases(s))

9. Design responsibilities:

Atwood & Morrill Co.

10. Tests conducted: hydrostatic L] pneumatic DI design pressure EI pressure*ILA_

psi Code Case(s)

NB-81 This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 Rev. 8

(s.

Drycriptionsofowork:e Attahed (use of properly identified additional sheet(s) or skelch(es) is acceptable)

See Attached Manufacturer's Data Report CERTIFICATE OF COMPLIANCE I,

David McCathie certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacement activities described above conforms to Section XI of the ASME Code and the National Board Inspection Code "NR" rules.

National Board Certificate of Authorization No.

MR-8 6 to use the "NR" stamp expires 5/25,2003 NR Certificate Holder Continental Field Systems,, Inc Dat*.JI.

2.0_02Signed Cag.

-me)Q.

(_

L Quality Control Manager (authorized representative)

(title)

CERTIFICATE OF INSPECTION I, WU.-WM Z

6-C5 M. holding a valid commission issued b The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of [CH $SJ.

V4,W414 and employed by FAcrtory Muru/L. Zv*I V tu,c Cotoy',evy of J oI4P4.,ro eI have inspected the repair, modification or replacement described in this report on

-. IL2

.p._and state that to the best of my knowledge and belief, this repair, modification or replacement activity has been completed in accordance with Section XI of the ASME Cod&0and the National Board Inspection Code "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning the work described in this report. Furthermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected with this inspection.

Date J"-W/ Z4 Z 0QZ Signed.

V

,,,&.A-

=

CommissionsWU87 9 60Ar*.,

RV4JP FA ZC2O o.pe~

(Natio....oad.(.

edre et) ju dcinadn.

12. Remarks:

See Attached work:

11. Description of (National Board (incl. endorsements), Nui~ictiom and no.)

(-spect*

Form NR-1 Attachment Worked Performed by Continental Field Systems, Inc.

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D Items Which Required Repair, Modification, or Replacement Activities Identification 1%

41 Report of Repair / Replacement Job Number 3218 k_-onst ucton Code No Type of Item Mfg. Name Mfg. Serial Nat'l Bd.

Jurisdiction Other Year Name/ Section/

Edition /

Code Code Class Repair/

No.

No.

Built Division Addenda Case(s)

Replace I

MSIV A&M 8-221 N/A N/A N/A 1974 ASME Ill/NB 1971/S71 1535-2 I

Repair 2

Items Installed During Replacement Activities Identification Construction Code Item Installed/

MFG.

Mfg. Serial Nat'l Jurisd. No.

Other Year Built Name/

Edition/

Code Code Replaced Name No.

Bd. No.

Section/

Addenda Case(s)

Class Division Poppet Replaced A&M 6

N/A N/A N/A 2001 Ill NB 71 Ed. S71 A N/A I

Bonnet Replaced A&M 2

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Pilot Poppet Replaced A&M 2

N/A N/A N/A 2001 III NB 71 Ed. S71 A N/A I

Super Nuts Replaced A&M NU-0 1017 N/A N/A N/A 2002 III NB 71 Ed. S71 A N/A I

1 of 2

Report of Repair / Replacement Worked Performed by Continental Field Systems, Inc.

23 Westgate Blvd., Savannah, Georgia 31405 Owner: PPL LLC 2 North 9 th St., Allentown, Pennsylvania Location: PPL SSES 5 Mi. N. Berwick, Pennsylvania System: Main Steam 183 Valve HV 141 F028D

6. ASME Code Section XI applicable for inservice inspection: 1989 (edition)
7. ASME Code Section XI used for repairs, modifications, or replacements: 1989 (edition)
8. Construction Code used for repairs, modifications, or replacements:

1971 (edition)

Job Number 3218 N/A N/

(addenda)

(Ci N/A (addenda)

Summer 71 (addenda)

A ode Case(s))

N/A (Code Case(s))

I Code Case

9. Design Responsibilities: Atwood & Morrill
10. Test Conducted N/A
11. Description of Work: Perform in body machining to allow clearances for modified poppet, remove OEM parts, and Ir replace with new components from OEM as part of valve enhancement.
12. Remarks: Lower guide rib was extended to compensate for the installation of the re-designed poppet.

2 of 2 Form NR-1 Attachment

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder]
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603

-name and address ot Iurc aserl

3. Location of installation Susquehanna I 2 North Ninth Street Allentown, PA 18101-1179 (name and address)





r Ds

4

  • A 4nlK C*

II R1 600 PSI N/A 2001

.3LlUtU L

exv.

,60 PSI.'--.---~'r~.

ier tmhl spec.

(yer ud (drawing no.)

5. ASME Code,Section III, Division 1:

(Mari. &Pee, no (editon)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

"S7t1 1

N/A 197 S71 N/A Revision N/A Date N/A

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 3 Cover A&M P/N 32162-409-2974-000 QLA (A&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Nom. Thickness (In.)

5.312 Min. design thickness (in.)

5.094 Dia. ID (ft & in.)

N/A Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report Part or Appurtenance Serial Number HT: H3391 S/N 1 National Board No.

In Numerical Order N/A HT: H3391 S/N 2 N/A HT: H3391 S/N 3 N/A 4-4.

.3.

+

Part or Appurtenance Serial Number (26)

(27)

_(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

I I

4 National Board No.

In Numerical Order I

_________________________ 4-

_________________________ 4.

_________________________ 4.

_________________________ +

_________________________ +

_________________________ 4

-4 4.

.4.

L (39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

I I

4

0. Design pressure 1250 psi.

Temp.

575 "F. Hydro. test pressure

  • Supplemental Information In the form of lists. sketches, or drawings may be used provided (1 ) size Is 8 % xI 1. (2) Information In Items 2 and 3 on this Date Report Is Included on each sheet is numbered and the number of sheets is recorded at the top of this form.

This form JE00040) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.

4. Type.

Pg. 1 of 2 (1)

- (2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

N/A

(*oen applcable)

At temp. *F L(50) j (class) islolsnoi

-~gj

{1218e)

Reprint (7191)

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: H3391 S/N 1 through SIN 3 CERTIFICATION OF DESIGN Design specifications certified by Design report

  • certified by N/A (when applficabe)

N/A (when applicable)

P.E. State N/A P.E. State N/A Reg. no.

N/A Reg. no.

N/A CERTIFICATE OF COMI We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

Date N2607 Expires Name Atwood & Morrill Co., Inc.

(NPT Cordficite Ho4der) 6-1 3-04

_0 Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by i-.fl.11.1 at I.,U.

of Hartford, CT have inspected these items described in this Data Report on

/W21'/0 and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section

"* Divisibn 1. Each part listed has been authorized for stamping on the date shown above.

signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the equipment described

.,i this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection Date Signed Commissions (authonzea Kwpec~tor (Nal 8d. (ind. Endomwments) an staw or prov. and no]

Cover IV (outgo-Azed representatiYO) tt I*

t 0 I

dP"*A

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (name and address of NPT Certificate Holder)
2. Manufactured for Pennsylvania Power & Light - Berwick, PA 18603 (name and address of Purchaser)
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 (name and address)
4. Type:

"32462-613-C Rev.0 SA 479-304 85,700 PSI N/A 2001 (drawing no.)

(marl. spec. no.)

(tensile strength)

(CRl)

(yea bjiql

5. ASME Code,Section III, Division 1:

. 1971 S71 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A' Revision N/A Date N/A (no.)

7. Remarks:

Cust. Item 01 A&M Item 11 Qty. 8 Pilot Poppet A&M P/N 32462-613-4226-121 QLA (LA&M S.O. 90168) *Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition Summer 1971 addenda

8. Nom. Thickness (in.)

1.50 Min. design thickness (in.)

1.36 Dia. ID (ft & in.)

N/A

. Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report:

(1)

(2)

(3)

(4)

(5)

(6)

(7).

(8)

(1)

(10)

(11)

(12)

Part or Appurtenance Serial Number HT: 54682 S/N 1 HT: 54682 S/N 2 HT: 54682 S/N 3 HT: 54682 S/N 4 HT: 54682 S/N 5 HT: 54682 S/N 6 HT: 54682 S/N 8 HT: 54682 S/N 9 (14)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

10. Design pressure National Board No.

In Numerical Order N/A N/A N/A N/A N/A N/A N/A N/A 1250 psi.

Temp.

Part or Appurtenance National Serial Number Board No.

In Numerical Order (26).

(27)

.(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(.38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

  • (50)
  • e J..J....

.ree inKIIA At temp. '17ryuu ct J

e~,

w

  • Supplemental Information In the form of lists. sketches, or drawings may be used provided (1) size Is a 'A x I 1, (2) Information In Items 2 and 3 on this Data Report 15 Included on each sheet Is numbered and the number of sheets Is recorded at the top of this form.

(12188)

This form (E00040) may be obtained from the.Order Dept. ASME. 22 Law Drive, Box 2300, Fairfield, NJ. 07007-2300.

ReprInt (71 911 575.

nyro.

p.(when applicable)}

FORM N-2 (Back - Pg. 2 of 2)

Certificate Holders' Serial Nos.

HT: 54682 S/N 1 through S/N 6, 8 & 9 CERTIFICATION OF DESIGN Design specifications certified by Design report certified by N/A

(,he.n appficaWI.)

N/A (when applicable)

P.E. State N/A P.E. State N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N2607 Expires Pilot Poppet 6-13-04~

Atwood & Morrill Co., Inc.

(NFT CatblIcate Hoid.E Signed 701 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of And employed by HSB.I & I. Co.

of Hartford, CT have Inspected these Items described in this Data Report on and state that to the st of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordgfncefwith the ASME Code, Section Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions tJlX -$ P7 e,0',A 1 Date l~fl

-ed Enosmen ndaae v

an n.1 Reg. no.

Reg. no.

N/A N/A Date Name Nw Ynrk 6-13-04 m

m HSBI&I Co.

(au*,otiz ed representative Signed

([Narl 8d. find. EndorserenWs) IMd sut of pray. and no.]

FOR INFORMATION ONLY FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required.by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production

1. Manufactured and certified by Atwood & Morrill Co., Inc. 285 Canal Street Salem, MA 01970 (nane and &ddomeu of NPT CetSicate Molder)
2. Manufactured for Pennsylvania Power & Light Berwick, PA 18603 (name and adress of PurthlINd
3. Location of installation Susquehanna II 2 North Ninth Street Allentown, PA 18101-1179 Iname and adrhss)
4. Type:

32467-622-D Rev.7 (dra i i nion1)

.5. ASME Code.Section III, Division 1:

SA 105 GRII (marl spec. no.)

1971 (odmoid 77.100 PSI i$7a1 strong" S71 N/A I

IIOeO3 daia)

6. Fabricated In accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date (Re) 7, Remarks=:

Cust.Item 01 A&M Item 11 Qty.1 Poppet A&M P/N 32162-409-2974-000_OLA 2001 N/A (cod. case no.)

N/A (A&M S.O. 90168) -Dwg. prepared by A&M. This certification meets the required information of ASME Section III 1971 Edition summer 1971 addenda

8. Nom. Thickness (in.)

7.500 Min. design thickness (in.)

5.49 Dia. ID (ft I In.)

N/A Length overall (ft& In.)

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each Item of this report Part or Appurtenance Serial Number HT: 245951 S/N 6 National Board No.

in Numerical Order N/A 1.

Part or Appurtenance

.Serial Number (26)

(27)

(2a)

(29)

(30)

(31)

(3M)

(33)

(34)

(35)

(36)

P7)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

National Board No.

In Numerical Order

10. Design pressure 1250 psL Temp.

575

"*F.

Hydro. test pressure "Supplemental ldnfmtaloIn ithe form ot l*at, as hes, or drawings may be used provided I ) sin s I % x 11. (2) ndormtiaon In hems 2 and 3 on this Oaft Report is included 00 each shoe is lumbered and Ot number of shoet is recorded at te top of 0la form.

(12mS5)

This form (E00040) may be obtaind from ite Order Dept.. ASME 2 Law Ora. Box 20, Fablld. NJ 07007-2300.

Pg. 1 of 2 (1)

(2)

(3)

(4)

(5)

(a)

(7)

(a)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(17)

(18)

(20)

(21)

(22)

(23)

(24)

.j2)

N/A (When spoicabse).

At temp. "F Expires On:\\?

Assigned to: ????

FOR INFORMATION ONLY Reprint 71 Iti)

FORM N-2 (Back - Pg.2 of 2)

Certificate Holders' Serial Nos.

HT: 245951 S/N 6 through N/A CERTIFICATION OF DESIGN Design specifications certified by N/A P.E.

N/A Reg. no.

N/A State Design report certifed by N/A P.E.

N/A Reg. no.

N/A State

  • 0*-,pph-bt)

CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this (these)

Poppet' conforms to the rules of con.truction of the ASME Code, Secdon III, Division 1.

NPT Certificate of Authorization No.

N2607 Expires.

6-13-04 Date

/49 91 Name Atwood & Morrill Co., Inc.

Signed (NMr Ce.afit Htddw)

(Uftwized rip,,eanwW3 CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York And employed by H.S.B.I & I. Co.

of Hartford, CT have inspected these items described in this Data Report on 4; /-Z

' /

, and state that.to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section Ill. Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described In this Data Report. Furthermore, neither the Inspector nor his employer shall be Hable In any manner for any personal Injury or property damage or loss of any kind arising from or connected with this inspection.

Date Z2 Signed Commissions

>v*,

d)7

.. X A4J"

/

./(

aUVW-

-S an ad.

POAL E.ndorawfruA a WA SUW or i"

. and n7.j r.t Expires On: \\??

Assigned to: t???e

APPENDIX D.3 SNUBBER REPLACEMENT NIS-2 FORMS

ISI SNUBBER REPLACEMENT AND REPAIR NIS-2

SUMMARY

1.0 INTRODUCTION

This summary identifies the work performed on ASME Section XI Snubbers (Classes 1, 2 or 3 Safety Related Snubbers, parts for replacements and repairs for which ISI has NIS-2 responsibility). This work was performed during the Unit 1 - 12th Refueling and Inspection Outage.

2.0 CODE COMPLIANCE

SUMMARY

All work on ASME Section XI items meet the requirements of IWA-7000 (Replacement) and IWA-4000 (Repair) of ASME Section XI 1989 Edition, no Addenda.

3.0 REPLACEMENT AND REPAIR

SUMMARY

Work in this area consists of Work Orders for Section XI replacements of snubbers, parts and ASME Section XI Repair.

3.A Summary of replacements for snubbers, by system, Work Order Number and Support Number (see Attachment 3.A).

3.B Summary of replacement of snubber parts by system, Work Order Number, Support Number, and Replaced Parts (See Attachment 3.B).

3.C Summary of repair tack weld shim by System, Work Order Number, Support Number by System, and Repair (see Attachment 3.C).

H:\\snubbers\\snubrepr.doc

.A SNUBBERS REPLACED H:\\snubbers\\snubrepr.doc N-5 SUS.

WORK ORDER SUPPORT IDENTIFICATION I

183A-II 311260 DBB101H5B 183E-111 299126 SPHCC131H2019 183E-III 299126 SPHCC138H2009 I

I I

i

ATTACHMENT 3.B REPLACEMENT OF SNUBBER PARTS H:\\snubbers\\snubrepr.doc N-5 SUS.

WORK ORDER SUPPORT REPLACED PARTS IDENTIFICATION 161 B-I 311258 DBA101H8 1 Load Stud, 2 Heavy Hex Nuts 4

4 i

I I

ý

ATTACHMENT 3.C REPAIR OF SUPPORT PART H:\\snubbers\\snubrepr.doc N-5 SUS.

WORK ORDER SUPPORT REPAIR PART IDENTIFICATION 149A-II 390868 GBB104H8 Large Bore Pipe Support (SHIM)

T r

1 4-

+

I h

149A-II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Susc Two North Ninth St., Allentc Address
4. Identification of System Date Sheet Unit 5/03/02 1

of One Maint PCWO Code Form No.

390868 102149004 Repair Organization P.O. No.. Job No.. etc.

quehanna, LLC Type Code Symbol Stamp None Name

)wn, PA 18101 Authorization No.

N/A Expiration Date N/A 149A, Class II, RHR System - Pool Spray, Pumps and Auxiliary

5. (a) Applicable Construction Code III 19 71
Edition, thru W72
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 No Add.
6. Identification of Components Repaired or Replaced and Replacement Components
7. Description of Work Repaired by tack welding of SHIM.
8. Tests Conducted:

Hydrostatic F Pneumatic r-Nominal Operating Pressure E

None X Other F

Pressure psi Test Temp.

°F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y2 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (EO0030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017 ASME National

Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Large Pipe Support Bechtel N/A N/A GBB104H8 1982 Repaired No (SHIM)

I 4

4 4

1

+

4 4

1 4

I t

t t

(12/82)

FORM NIS-2 (Back)

9. Remarks N/A Aoolicable Manufacturer's Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A f-Date Signed 4

Date 20 02 Kaer or 0YIser's

,Tte Spv ieMdfiain ru CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

(L,}/aj (7"*

aureCommissions NB7980 I PA 2204 Inspector's National Board, State, Province, and Endorsements Date MA&? LO 2002

)

161 B-I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603 Address
3. Work Performed by PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit MAIN/PCWO 311258 5/03102 1

of ONE Code Form No.

I 02 161 005 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp None Authorization No.

N/A Expiration Date N/A

4. Identification of System 161 B, Class I, Reactor Water Clean-Up
5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 NO ADD.
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component r

r I

Name of Manufacturer Manufacturer Serial No.

National Board No.

Other Identification Year Built

Repaired, Replaced, or Replacement ASME Code Stamped (Yes or No) 1 Load Stud GRINNEL Item #13*(1)

N/A DBA101H8 (1)

Replaced NO 1 Load Stud GRINNEL Item #13"(1)

N/A DBA101H8 (1)

Replacement NO 2 Heavy Hex Nuts GRINNEL Item #14*(1)

N/A DBA101H8

  • (1)

Replaced NO 2 Heavy Hex Nuts GRINNEL Item #14"(1)

N/A DBA101H8

  • (1)

Replacement NO I10 I r-t 1Iz: Srnar/-leat iNuiber arln T ear Built Not AvailaDle.

7. Description of Work Replaced existing parts with sufficient replacement parts.
8. Tests Conducted:

Hydrostatic []

Pneumatic El Nominal Operating Pressure r-1 None X Other R

Pressure psi Test Temp.

"F S

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (EO0030) may be obtained from the Order Dept, ASME, 345 E. 47th SL, New York, N. Y. 10017 Expiration Date (12/82)

FORM NIS-2 (Back)

9. Remarks N/A Applicable Manufacturers Data Reoorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.

repair or rep4acerneni Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Date Signed 6 1,

Date

,20 02 Orn er or rer&

Destindee, Ti e '

S~pv. Sit. Modificatiorns Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________________7__Commissions NB7980 I PA 2204 Inspector's Si~lgature National Board, State, Province, and Endorsements Date MA',/

10 2002

)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd, Berwick, PA 18603

3. Work Performed by Address PPL Susquehanna, LLC Name Unit Main/PCWO 311260 ONE Code Form No.

I 02183001 Repair Organization P.O. No., Job No., etc.

Type Code Symbol Stamp None Two North Ninth St., Allentown, PA 18101

4. Identification of System Address Authorization No.

Expiration Date N/A N/A 183A, Class 11, MAIN STEAM

5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Code Case ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Mechanical Shock Pacific Scientific 00373 N/A DBB101H5B None Replaced No Arrestor Mechanical Shock Pacific Scientific 14413 N/A DBB101H5B 1983 Replacement No Arrestor

7. Description of Work Replaced existing snubber with same size, tested replacement snubber.
8. Tests Conducted:

Hydrostatic 0

Pneumatic E

Nominal Operating Pressure Other 0 Pressure psi Test Temp.

El.F None X NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81 in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant 183A-II Date 5/03/02 Sheet 1

of I

(12/82)

FORM NIS-2 (Back)

9. Remarks N/A Aoolicable Manufacturer's Data Recorts to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration N/A Date Sign Date

/

.20 02 Own or Owners f)"gnee. Title Supv. -Site Modifications Group CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON, RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'/?

q Commissions NB7980 I PA 2204 InspectorYSignature National Board, State, Province, and Endorsements

,Date M. y

/&

2002

'I 1-Th

-)

)

183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North N inth St., Allentown, PA 18 10 1 Address Susquehanna Steam Electric Station Date Sheet Unit 5/03/02 1

of ONE Name 769 Salem Blvd, Berwick, PA 18603 Address

3. Work Performed by PPL Susquehan Name Two North Ninth St., Allentown, P.

Address

4. Identification of System MAIN/PCWO See Sheet 2 of 2 Code Form No.

Kepair Organization P.O. No., Job No., etc.

Ina, LLC Type Code Symbol Stamp None A 18101 Authorization No.

N/A Expiration Date N/A 183E, Class Ill, Auto Pressure Blow Down System

5. (a) Applicable Construction Code III 19 71
Edition, thru W72 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 NO ADD.
6. Identification of Components Repaired or Replaced and Replacement Components
Addenda, N/A ASME National
Repaired, Code Name of Name of Manufacturer Board Other Year Replaced, or Stamped Component Manufacturer Serial No.

No.

Identification Built Replacement (Yes or No)

Mechanical Shock Pacific Scientific 27972 N/A SPHCC131H2019 1982 Replaced NO Arrestor Mechanical Shock Pacific Scientific 16349 N/A SPHCC131H2019 1980 Replacement NO Arrestor Mechanical Shock Pacific Scientific 22868 N/A SPHCC138H2009 1981 Replaced NO Arrestor Mechanical Shock Pacific Scientific 13130 N/A SPHCC138H2009 1980 Replacement NO Arrestor

7. Description of Work Replaced existing snubbers with same size, tested replacement snubbers.
8. Tests Conducted:

Hydrostatic E Pneumatic 0

Nominal Operating Pressure E

None X Other E-Pressure psi Test Temp.

°F PNOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y in. x 11 in., (2) informa tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47th St., New York, N. Y. 10017

1. Owner
2. Plant Code Case

[tern ter 2

(12/82)

FORM NIS-2 (Back)

9. Remarks N/A Aoolicable Manufacturer's Data Reoors to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement N/A Expiration Date

'I

,20 02 Date Le, Title Supv. - bite Mocnlncations Group N/A N/A Type Code Symbol Stamp Certificate of Authorization No.

CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PENNSYLVANIA and employed by FACTORY MUTUAL INSURANCE CO.

of JOHNSTON. RHODE ISLAND have inspected the components described in this Owner's Report during the period 03/01/02 to 04/01/02

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________._______-___I_-__

_Commissions NB7980 I PA 2204 Inspector's Soature National Board, State, Province, and Endorsements Date/Iof/

/0 2002

)

Date 11

,20 02

183E-III FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Susquehanna Steam Electric Station Name 769 Salem Blvd. Berwick, PA 18603

3. Work Performed by Address PPL Susquehanna, LLC Name Two North Ninth St., Allentown, PA 18101 Address Date Sheet Unit 5/03/02 2

of 2

ONE Maint/PCWO

/CodeFormNo.

SEE BELOW Repair Organization P.O. No., Job No., etc.

Type Code Symbol None Authorization No.

N/A Expiration Date N/A

4. Identification of System 183E, Class III, Auto Pressure Blow Down System
5. (a) Applicable Construction Code III 19 71
Edition, thru W'72
Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components S-I 1

ITEM(S)

WORK ORDER NO.

CODE REPAIR FORM NO.

1 299126 1 02 183 002 2

299126 1 02 183 003 I.

4 t

I 1-4 i

i.

1. Owner
2. Plant

[_________________

i I

-I

APPENDIX E EROSION/CORROSION SCOPE OF EXAMINATIONS

Unit One - 12th - Li-Aon/Corrosion Exams 3

COMPONENT ID DBB1222-El DBC1011 -El DBD1 01 2-E4A/B DBD1043-El DBD1 051 -E7A/B DBD1 051 -E8 DLA1 021 -E3A/B EBC1041-E2 EBD1 143-E2A/B GBD1 01 3-E2 GBD1021-E2 GBD1022-El GBD1031-ElA/B GBD1033-ElA/B GBD1042-El GBD1074-E2 GBD1 193-El GBD1213-E2 GBD1214-E2 GBD1261-El GBD1361-ElA/B GBD1401-El GBD1401-E2 HBD1141 -El HBD1 141 -E2 HBD1212-E4ANB HBD1681-E3 SPEAD1 148-El SPEBD1 141-El SPGBD1 3311-El SPGBD13320-El SPGBD13322-El SPGBD1 337-El SPHBD1092-El SPHBD1096-E2 SPHBD10742-El 1SCVL-E12 1 SSH7-E3 1 SSH8-E25A/B DESCRIPTION 4" TEE TEE 6"x 4" 30x24" TEE 1Oxl0 TEE TEE16x4" ELB/1 6" TEE/20X12 ORIFICE/4" TEE/4xl" RED/1 0"x8" ELB/4 ELB/4" RED/8x6 RED/8x6 ELB/3" ELB/16" ELB/20" ELB/20" ELB/20" VALVE/8" RED/1 4x1 2" ELB/3" ELB/3" ELB/3" ELB/3 TEE/48x30" ELB/4 TEE/4xl" ELB/1" ELB/1" ELB/1" ELB/.75" ELB/1" ELB/2" VALVE/2" ELB/2" ELB/1.5 ELB/5" RED/8x5 X NUMBER (X502)

(X695)

(X51)

(X153)

(X68)

(X54)

(X-1 75)

(X499)

(X683)

(X790)

(X-1 55)

(X191)

(X791)

(X795)

(X158)

(X57)

(X148)

(X49)

(X60)

(X218)

(X797)

(X295)

(X32)

(X304)

(X-34)

(X56)

(X816)

(X190)

(X-134)

(X208)

(X211)

(X213)

(X207)

(X205)

(X201)

(X38)

(X-173)

(X189)

(X188)

%Ero 0%

21.9% BZ2 25.5% BZ3 2.3% Z3 60.7% Z1 70.5% Z3 27.9% BZ4 8.0% Zi 7.4% AZ1 0%

63.3% Z1 56.96% Z1 0%

37.4% AZ1 31.0% Z3 18.7% Z3

.7% Z3 13.2% Z1 2.6% Z3 52.3% Z1 28% AZ3 34% Z3 1% Z3 50.0% Z1 48.6% Z3 22.4% BZ2A 30.0% Z3 4.08% Z1 25.8% Z3 32.1% Z3 15.7% Z3 2.7% Z3 36.9% Z3 46.6% Z3 56.4% Z3 20.5% Z3 25.5% Z1 1.2% Z3 8.1% BZ3

SUnit One-12th-List c hon/Corrosion Exams

,W 2SCVL-E24 ELB/1.5 (X370) 31.3% Z1 1E101A-ElShell FWHTR (X888) 33.1% Z3 1E101 A-El Nozzle 24" Pipe (X888) 45.5% AZ1 1 E102A-E1 Shell FWHTR (X891) 30.4% Z2 1 El 02A-E1 Nozzle 24" Pipe (X891) 0%

APPENDIX F CONTAINMENT INSPECTIONS

I)

I IIIIII III I

I Drywel! Head Head and Flange Manhole Hatch GV GV 794' t

I ______

L _____

I ___

Personnel Access Airlock (X-2)

External Door GV 724' 1340 2A 2A 3A, C, D.) L 3A, C, Internal door GV 724' 1340 D, L 1

1 1

1 1

External Bulkhead GV 3C, H 1

1 r

.4-4 ___

1 _____

Internal Bulkhead GV 3C, L I

I r

I- *4

  • 1 _____

I _____

I An9 G:\\ISI\\IWL\\outage U1-12 sched.xis I

th UNITI1-12 RIO 1

001 001 002 002 1

1 345549 345549 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1

__________________________________________ L

__________ L

.L.................L...................I

____________ 1 ______________.1

_______________ L 002 0023 I

1 1

Page 1 of 34 I.

I I

11 1

1 1

1 1

1 1

1 1

1 1

i r-F-I I

I I

G:\\ISl\\IWL\\outage U1-12 sched.xls UNIT 1 - ý2th RIO 1I T

~Iv

~

i$~

i~ 9XXXNDE-VT Barrel Section GV 3G 1

1 1

002 345565 003 Rev 1 Equipment Hatch (X-!)

NDE-VT Head and Flange GV 724' 3150 4A. 4B 1

1 1

003 345565 003 Rev 1 NDE-VT Barrel Section GV 724' 3150 4A. 4B 1

1 1

003 345565 003 Rev 1 Examination Category: E-A, Containment Surfaces EI1O1 Containment Vessel Pressure Retainting Boundary,__

E!i.

ACcessible SUrface Areas i:

Drywell - Exterior 704' -

0° to

__Drywell Exterior GV 719' 900 30 NDE-VT X-34B GV 704' 19° 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-35A GV 717' 5Q0 30 1

1 1

004 345565 003 Rev 1 NDE-VT~

X-35B GV 717' 48° 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-35C GV 717' 460 30 1

1 1

004 345565 003 Rev 1 Page 2 of 34

I

~ti~i~f1Exa Exa Dw.

PeiodRepot #Insp Ith~

~

ie z,

Ck 12::1 m9~X rcedu0re NDE-VT X-35D GV 717' 440 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-35E GV 717' 410 30 1

1 1

004 345565 003 Revl1 NDE-VT X-35F GV 717' 390 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-49B GV 705' 44' 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-83B GV 705' 150 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-93 GV 717' 370 30 1

1 1

004 345565 003 Rev 1 NDE-VT X-100H GV 711' 530 30 1

1 1

004 345565 003 Revl1 NDE-VT X-104H GV 711' 22° 30 1

1 1

004 345565 003 Revl1 NDE-VT X-104F GV 711' 360 30 1

1 1

004 345565 003 Revl1 704'-

90°-to Drywell Exterior GV 719' 1800 31 NDE-VT X-11 GV 708' 1470 31 1

1 004 345565 003 Revl1 NDE-VT X-12 GV 710' 1760 31 1

1 1

004 345565 003 Revl1 NDE-VT X-13B GV 710' 1610 31 1

1 1

004 345565 003 Revl1 NDE-VT X-15 GV 709' 1240 31 1

1 1

004 345565 003 Revl1 NDE-VT X-90D GV 711' 1410 31 1

1 1

004 345565 003 Revl1 G:\\ISI\\IWL\\outage U1-12 sched.xls U th UNIT I - 12t RIO 4,

Page 3 of 34

I)

UNIT 1 RIO ND-V X-18 GV 709' 127° 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-19 GV 709' 1200 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-30B GV 705' 1320 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-33B GV 705' 1250 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-34A GV 705' 1540 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-48A GV 705' 1570 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-50B GV 705' 1420 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-51B GV 705' 1450 31 1

1 1

004 345565 '003Revl1 NDE-VT X-52B GV 705' 1370 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-83A GV 705' 1500 31 1

1 1

004 345565 003 Rev 1 NDE-VT X-90E GV 711' 1370 31 1

1 1

004 345565 003 Revl1 NDE-VT X-90F GV 711' 1330 31 1

1 1

004 345565 003 Rev 1 704'-

1800 to

__Drywell Exterior GV 719' 2700 32 NDE-VT X-6 (CR0 Hatch)

GV 718' 216° 32 1

1 1

004 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 4 of 34

A, UNIT 1 - 1 2 th RIO I II I

I T

-X-10

-X-13A

-X-17 X-23 X-24 X-25 X-50A X-72A X-72B Drywell Exterior X-30A X-33A X-49A X-51A GV GV GV GV GV GV GV GV GV GV GV GV GV GV 714' 710' 710' 709' 709' 710' 705' 704' 704' 704' 719' 710' 708' 704' 704' 2090 199*

2470o 186' 1830 2360 2150 2290 2310° 270° to 3600 322'° 327o 3270 L3240 32 32 32 32 32 32 32 32 32 33 33 33 33 33 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 5 of 34 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

004 004 004 004 004 004 004 004 004 004 004 004 004 345565 003 Rev 1 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 IJUt--V I 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev I NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 1(

I I

I I

I I --,

II I-II I

I I

I I

I.- I I I

I)

I G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO Al NDE-VT X-52A GV 708' 3230 33 1

1 1

004 345565 003 Rev 1 ND E-VT X-90A GV 711' 3280 33 1

1 1

004 345565 003 Revl1 NDE-VT X-90B GV 711' 3320 33 1

1 1

004 345565 003 Revl1 NDE-VT X-90C GV 711' 336° 33 1

1 1

004 345565 003 Rev 1 NDE-VT X-100G GV 711' 3130 33 1

1 1

004 345565 003 Revl1 NDE-VT X-104E GV 706' 3480 33 1

1 1

004 345565 003 Rev 1 NDE-VT X-104G GV 711' 3530 33 1

1 1

004 345565 003 Revl1 719'-

O0°to Drywell Exterior GV 749' 9Q0 34 NDE-VT X-8 GV 731' 00 34 1

1 1

005 345565 003 Revl1 NDE-VT X-21 GV 731' 4Q0 34 1

1 1

005 345565 003 RevI1 NDE-VT X-22 GV 734w 430 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-27B GV 726' 610 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-28B GV 729' 610 34 1

1 1

005 345565 003 Revl1 NDE-VT X-29B GV 732'

61.

34 1

1 1

005 345565 003 Rev 1 Page 6 of 34

I)

I II I

III I

III

-I X-37D GV 1 735' 780 34 1

1 1

005l 1

i i

4 I

I I

I I__

I I

I u

I X-38D X-40E X-40F X-40G X-40H X-44 x-46 GV GV GV GV GV GV GV 735' 729' 729' 729' 729' 726' 727' t

____-_I_-

I X-48B X-53 X-54 X-58B X-60B GV GV GV GV GV 732' 736' 736' 735' 735' 780 770 730 690 650 120

0.

650 390 510 650 610 X-61B

[GV 726' 650 X-62B GV 726' 69° 34 34 34 34 34 34 34 34 34 34 34 34 34 34 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 005 1

005 1

1 1

1 1

1 1

005 005 005 005 005 005 005 005 005 005 005 005 G:\\ISI\\lWL\\outage U1-12 sched.xls UNIT '-12 RIO 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 I

I I

7-ý Page 7 of 34

-t

-T

-r I


F F

-r I

-r I

I i

i-tI I0 i

-F--

i i

I -

-r I

I I

-I-i iL F

58

-L I -f-11 I

I I

I I

41

.m Repo.t.

t um NDE-VT X-63B GV 726' 730 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-64B GV 726' 770 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-87 GV 734' 460 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-91B GV 732' 570 34 1

1 1

005 345565 003 Revl1 NDE-VT X-92 GV 735w 570 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-94 GV 734w 370 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-7A GV 740' 0° +43 34 1

1 1

005 345565 003 Rev 1 NDE-VT X-7B GV 740' 0° +11 34 1

1 1

005 345565 003 Revl1 719'-

90° to Drywell Exterior GV 749' 180° 35 NDE-VT X-31B GV 726' 1620 35 1

1 1

005 345565 003 Rev 1 NDE-VT X-37B GV 735' 1020 35 1

1 1

005 345565 003 IRev 1 X-38B GV 735' 1020 35 1

1 1

005 345565 003 IRev 1 X-80A GV 726' 1590 35 1

1 1

005 345565 003 Rev 1 X-80B GV 726' 1560 35 1

1 1

005 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1-12t RIO Page 8 of 34

UNIT 12 RIO NDE-VT X-80C GV 726' 1530 35 1

1 1

005 345565 003 Rev 1 NDE-VT X-86A GV 735' 115° 35 1

1 1

005 345565 003 Rev 1 ND E-V-T X-86B GV 735' 1120 35 1

1 1

005 345565 003 Rev 1 NDE-VT X-88A GV 721' 1140 35 1

1 1

005 345565 003 Revl1 NDE-VT X-91A GV 726' 165° 35 1

1 1

005 345565 003 Rev 1 719'-

1800 to

___Drywell Exterior GV 749' 2700 36 NDE-VT X-5 GV 724' 2390 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-27A GV 732' 2390 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-31A GV 732' 2280 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-37A GV 735' 2580 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-38A GV 735' 2580 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-40A GV 730' 2430 36 1

1 1

005 345565 003 Rev 1 NDE-VT X-40B GV 729' 2480 36 1

1 1

005 345565 003 Rev 1 ND E-VT iX-40C GV 735' 2430 36 1

1 1

005 345565 003 Rev 1 G:\\ISI\\IWL\\outage U1-12 sched.xis I

Page 9 of 34

J th UNIT'i -12 RIO I

I -

7 X-40D GV X-55 GV X-56 GV X-58A GV X-61A GV X-62A GV X-63A GV X-64A GV X-28A GV X-29A GV Drywell Exterior GV X-37C GV X-38C GV X-60A GV 732' 2430 736' 2230 736' 219° 735' 2280 726' 2430 726' 2480 726' 253' 729' 2530 739' 2480 739' 2430 79-270to*

749' 360' 735' 2820 735' 282' 726', 294o 36 36 36 36 36 36 36 36 36 36 37 37 37 37 1

1 1

1 1

1 1

1 1

1 1

1 1

1 I

G:\\ISI\\IWL\\outage U1-12 sched.xls Page 10 of 34 10 1

005 1

005 005 005 005 005 005 005 1

005 1

005 1

005 1

005 1

005 III-I I

I I

ULI-V I 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev 1 1NDE-VT 345565 003 Rev 1 NDE-VT 345565 003 Rev i1

I)

-X-85A GV 736'

-X-85B GV 736'

-X-88B GV 721' X-7C GV 740' X-7D GV 740' 749' Drywell Exterior GV 779' X-14 GV 750' X-9B GV 753' X-16B GV 763' X-20 GV 763' X-39B GV 763' X-45 GV 763' 749' Drywell Exterior GV 779' X-3B G:\\ISI\\IWL\\outage U1-12 sched.xis 31!

32:

291 00 0oo 00o 90 57' 0°0.

0.

21' 900 900 180 116 190 37 220 37

)50 37

-10 37

-3 37 to 0° 38 7-38

+3 38

+3 38 0

38

+6 38

-3 38 to 0° 39 39 Page 11 of 34 UNIT 1 - 12 RIO I,

1 1

1 1

1 1

1 1

1 1

I 1

1 1

1 1

1 1

1

1.

1 1

1 1

1 1

1 1

1 1

1 005 005 005 005 005 006 006 006 006 006 006 006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1

I isFlptr1 1.Exarr II

X-3D Drywell Exterior

'X-36 X-42 X-3A X-3C X-32B X-39A X-41 X-47 X-57 X-66B X-81 B X-82B GV GV GV GV GV GV GV GV GV GV GV GV GV I

WQK. j Inp*

756' 1120 749'-

180' to 779' 2700 750' 1900 750' 180' 756' 2480 756' 256o 757' 232' 753' 1950 754' 1860 757' 192' 755' 1900 757' 2280 756' 2360 39 40 40 40 40 40 40 40 40 40 40 40 40 40 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 12 of 34 UNIT i - 1 2 th RIO I

1 1 1

12R006 1 1 1

006 1 1 1

006 1 1 1

006 1 1 1

006 1 1 1

006 1 1 1

006 1

1 1

006 1

1 1

006 1

1 1

006 1

1 1

006 1

1 1

006 1 1 1

006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 F--7--7 i

lo X-84B X-59B X-65B Drywell Exterior X-32A X-66A

-X-81A X-82A X-84A X-26 X-59A X-65A X-9A X-16A GV GV GV GV GV GV GV GV GV GV GV GV GV GV G:\\ISI\\IWL\\outage U1-12 sched.xls Page 13 of 34 I)

UNIT -, - 12 th RIO

:::: :::: :::: : : :*:*::*: :::* *:*: ::: : * :* *;:: :*:* :*:* *:* *;* ` :* :
  • I 756' 775' 768'
749, 779' 756' 756' 756' 756' 756' 772' 775' 768' 753' 763' 2440 2280 2280 2700 to 3600 3090 305° 2930 2970 3010 780 3050 3050 00-3 0_-2 40 40 40 41 41 41 41 41 41 41 41 41 41 41 1

1 1

1 1

1 1

1 1

1 1

1 I

1 1

1 1

1 1

1 1

1 1

1 1

1 006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 1

006 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565 345565

  • L. F-v 1

003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1

NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N D E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N DE-VT 003 Rev 1

UNIT.4 2 th RIO D.

.i It4 Exami~i iiiiiiiiii wa ýI JI M

.R.e...

Dwg.

I at P.riod Drywell Exterior Drywell Exterior SDrywell Exterior Drywell Exterior GV Drywell Exterior GV Drywell Exterior Drywell Exterior Drywell Exterior 791' 791' 794' 00 to 900 900 to 1800 1800 to 2700 2700 to 3600 00 to 900 900 to 1800 1800 to 270° 3600 Examination Category: E-A, Containment Surfaces 42 1

43 1

44 1

45 1

1 no access this area no access this area no access this area no access this area 12R

007 345565 007 345565 007 345565 007 46 1

008 345565 47 1

1 1

008 345565 48 1

1 1

008 345565 49 1

1 1

008 345565 E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas 704D-I 0'5to Drywell Interior GV 719' 900 50 1

1 1

009 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 14 of 34 wQ#

345565 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 345566 360° H

i

I4 I

I I

X-34B X-35A X-35B X-35C X-35D X-35E X-35F X-49B X-1 04F X-83B X-93 X-100H X-104H Drywell Interior GV GV GV GV GV GV GV GV GV GV GV GV GV 719'-

704' 717' 717' 717' 717' 717' 717' 705' 711' 705' 717' 711' 711' 704' 719' 190 500 480 460 440 410 390 440 36' 150 370 530 220 900 to 1800 51 1

50 50 50 50 50 50 50 50 50 50 50 50 50 51 I

G:\\ISI\\IWL\\outage U 1-12 sched.xls Page 15 of 34 UNIT, - 12 th RIO 1

1 1

1 1

1 1

1 1

1 1

I 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 1

1 009 009 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345ý566(

I I

I I

NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 4NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND E-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-T 003 Rev 1 003 Rev 1 ND E-VT 003 Rev 1

G:\\ISI\\IWL\\outage U1-12 sched.xls Page 16 of 34 T

1 2 th UNIT,12 RIO

.X-11

-X-12 X-1 3B

-X-15

-X-18

-X-19 X-30B X-33B X-34A X-50B X-51 B X-52B X-83A X-90D X-90E GV 708' GV 710' GV 710' GV 709' GV 709' GV 709' GV 705' rGV 705' GV 705' GV 705' GV

705, GV 705' GV 705' GV 711' GV 1711' 1470 51 1760 51 1610° 51 1240 51 1270 51 120° 51 1320 51 1250 51 1540 51 1420 51 145° 51 1370 51 150° 51 1410 51 137° 51 I

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 I

NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566.003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009 345566 003 Rev 1 NDE-VT 009

_345566 1003 Rev,,

)

I I

I X-90F X-48A Drywell Interior X-6 (CRD Hatch)

X-10 X-13A X-17 X-23 X-24 X-25 X-50A X-72A X-72B Drywell Interior G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO GV GV GV GV GV GV GV GV GV GV GV GV GV GV 704' 719' 711' 705' 704' 719' 718' 714' 710' 710' 709' 709' 710' 705' 704' 704' 1330 157' 1800 to 2700 2160 2090 1990 2470 1860 1830 2360 2150 2290 231° 2700 to

.3Ri0° 51 51 52 52 52 52 52 52 52 52 52 52 52 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

009 009 009 009 009 009 009 009 009 009 009 009 009 009 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 i

I.

II I.

.. u I

vv 1

%3 I -

I NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 INDE-VT 003 Rev 1 JNDE-VT 003 Rev 1 NDE-VT 003 Rev 1

ý53 Page 17 of 34 i

i I

I i

iI

-t I

-L I

I t

I I

I I

1(

I I

I4 J X-30A

_X-33A X-49A X-51 A X-52A X-90A X-90B X-90C xX-100G X-104E X-104G Drywell Interior X-8 X-21 SG___V 710--

322__0_

GV 708' 3270 GV 704' 3270 GV 704' 324° GV 708' 323' GV 711' 3280 GV 711' 3320 GV 711' 3360 GV 711' 3130 PGV 706' 3480 GV 711' 3530

-ý -19'-

0° to GV 738' 90° GV 73 1' 00 FGV 7 344' 400°0 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 18 of 34

UNIT,

- 1 2 th RIO

-T 53 1

1 1

009 345566 53 1

1 1

009 345566 53 1

1 1

009 345566 53 1

1 1

009 345566 53 1

1 1

009 345566 53 1

009 3455660 53 11 009 345566 531 009 345566 0

531 009 345566 0

53 1

010 345566 C

53 1

1 1

010 345566 C

54 1

1 1

010 345566 0

541 010 345566 O0 NDNUI-T 003 Rev 1_

N DE -AVT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 ND-E-VT 003 Rev 1 KIDE-VT 003 Rev 1 NIDE-VT 003 Rev 1 NDE-VT D03 Rev 1 NDE-VT

)03 Rev 1

AN UNIT'i - 1 2 th RIO ili~iiiii!i i ! i NDE-VT X-22 GV 734' 430 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-27B GV 726' 610 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-28B GV 729' 610 54 1

1 1

010 345566 003 Rev 0 NDE-VT X-29B GV 732' 610 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-40E GV 729' 770 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-40F GV 729' 73 54 1

1 1

010 345566 003 Rev 1 X 4 0 GG V

7 2 6' 120 541 111 0N D E VT GGV 736' 39 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-540 GV 73' 651 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-58B GV 735' 60 54 1

1 1

010 345566 003 Rev 1 NDE-VT X-46 GV 727' 00 54 1

1 1

010 345566 003 Rev 1 X-4B V

72' 65° 5401 345566 003 Rev 1 X-48 GV 732' 650NDE-VT X-3G 3'

3° 54 1

1 1

010 345566 003 Rev 1 X-53GV 36' 390 4

1 1

1NDE-VT X-5 G

76' 51° 54 1

1 010 345566 003 Rev 1 X-54GV 36' 510NDE-VT X-8-G-35 5

54 1

1 1

010 345566 003 Rev 1 NDE-V IX-60B GV. 735'.

61 ° 541 11 010 34 5 6 0 e v 1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 19 of 34 I

I I

S Elix Exam X-619 X-62B X-63B X-64B X-87 X-91 B X-92 X-94 X-37D X-38D Drywell Interior X-31B X-80A X-80B GV GV GV GV GV GV GV GV GV GV GV GV

.lig 726' 726' 726' 726' 734' 732' 735' 734' 735' 735' 719' 738' 726' 726' 650 690 730 770 460 570 570 370 780 780 90° to 1800 1620 1590 54 54 54 54 54 54 54 54 54 54 55 55 55 55 1st Period 1

1 1

1 1

1 1

1 1

1 1

1 1

UNIT ' 1-2 th RIO i

1 1

1 1

1 1

1 1

1 1

1 1

1 WO#

1 1

1 1

1 1

1 1

G:\\ISI\\IWL\\outage U1-12 sched.xls Page 20 of 34 2......

Itr

zz=

I 010 010 010 010 010 010 010 010 010 010 010 010 010 010 Irisp

-F 17 IT 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 L.-

Report #x*:

i o Im INDS. U": r-T 14Tmmb Mii m

46i S.

ii

..... 30 W.,ý- U a &X=

1-003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 At

I UNIT 1

2 th RIO X-80C X-86A X-86B X-88A X-91 A X-37B X-38B Drywell Interior X-5 X-27A X-31A X-40A X-40B

X-400 C I

GV 726' GV 735' GV 735' GV 721' GV 726' GV 735' GV 735' 7--ý, -19' GV 738' GV 724' GV 732' GV 7321 GV 730' GV

729, GV 1735' 1530 1150 112' 1140 1650 1020 102o 180° -to 2700 2390 239 ° 228° 2430 55 55 55 55 55 55 55 56 56 56 56 56 56 56 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

G:\\ISI\\lWL\\outage Ul-12 sched.xls Page 21 of 34 I

I I

I I

- I I

I I

I 010 010 010 010 010 010 010 010 010 010 010 010 010 010 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 ND E-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDOE-VT 345566 003 Rev 1

1I I

MI.

-i.4l I....................

,JII t~PIIV~

1xm am j

Dg.

l

Ž2 Rpot I 1 1

2FidInnnKY I

I X-40D X-55 X-56 X-58A X-61A X-62A X-63A X-64A X-37A X-38A Drywell Interior X-60A X-85A X-85B GV GV GV GV GV GV GV GV GV GV GV GV GV 732' 736' 736' 735' 726' 726' 726' 729' 735' 735' 719' 738' 726' 2430 2230 2190 2280 243o 248' 253' 2530 2580 2580 2-ý70° to 360*

2940 3190 56 56 56 56 56 56 56 56 56 56 57 57 1

1 1

1 1

1 1

1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 22 of 34 UNIT,

12th RIO Is 010 010 010 010 010 010 010 010 010 010 010 010 010 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 '003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1 NDE-VT 345566 003 Rev 1

UNIT,-

1 2 th RIO Itei'

sflptI

X-88B X-37C X-38C Drywell Interior X-7A X-7B X-7D X-7C X-14 Drywell Interior Drywell Interior X-28A X-29A 1st Perloc GV 721' GV 735' GV 735' 7--38';.

GV 752' GV 740' GV 740' GV 740' GV 740' GV 750' GV 752' 738' GV 752' GVV 7'39__*'

G__V 739__'

A=

2950 2820° 2820 900 00 +3 00 +11 00-3 00 -10 570 90' to 1800 180' to 2700 2480 2430 G:\\ISI\\IWL\\outage Ul-12 sched.xls Page 23 of 34

)

Ion, 57 1

57 1

57 1

58 1

58 1

58 1

61 1

61 1

58 1

59 1

60 1

60 1_ _

1 1

1 1

1 1

1 F.....

RC L 1 1

1 1

1 1

1 1

1 1

1 1

010 345566 010 345566 010 345566 011 345566 C 011 345566 C

011 345566 C

011 345566 C

N 011 345566 0 K 011 345566 0

N 011 345566 0

N 011 345566 0i N

011 345566 01 N

011 345566 0(

NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT

)03 Rev 1 NDE-VT

)03 Rev 1 NDE-VT 003 Rev 1 JDE-VT D03 Rev 1 JDE-VT

)03 Rev 1 IDE-VT 03 Rev 1 DE-VT 03 Rev 1 DE-VT 03 Rev 1 DE-VT 03 Rev 1 i

X-36 GV X-42 GV Drywell Interior GV Drywell Interior GV X-9B GV X-16B GV X-20 GV X-39B GV X-45 GV Drywell Interior GV X-3B GV X-3D GV Drywell Interior GV G:\\ISI\\IWL\\outage U1-12 sched.xls

)-

th UNIT,12 RIO 750' 1900 750' 1800 738'-

2700 to 752' 3600 752'-

00°to 767' 900 753' 00 +3 763' 00 +3 763' 210 763' 00 +6 763' 90 o-3 752'-

90°to 767' 1800 757' 116' 756' 1120 J152'-

1-800 to 767' 2700_

Dwg.

60 60 61 62 62 62 62 62 62 63 63 63 64 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 fill" 1 : W 1

011 1

011 1

011 1

012 1

012 1

012 1

012 1

012 1

012 1

012 1

012 1

012 012 Page 24 of 34

-7 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 1

7

I)

I I

X-3A X-3C X-32B X-39A X-41 X-47 X-57 X-66B X-81 B X-82B X-84B Drywell Interior X-32A IX-66A GV GV GV GV GV GV GV GV GV GV GV GV GV GV 756' 756' 757' 753' 754' 757' 755' 757' 756' 756' 756' 7-5-2' 767' 3Q5 0

248 2560 2320 1950 1860 1920 1900 2280 2360 2400 2440 2700 to 3600 3090 3050 64 64 64 64 64 64 64 64 64 64 64 65 65 65 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 G:\\ISI\\IWL\\outage U1-12 sched.xls Page 25 of 34 0t UNIT

-12" RIO 012 012 012 012 012 012 012 012 012 012 012 012 012 012 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 I

I II I

I I

II I

I

X-81A GV X-82A GV X-84A GV X-9A GV X-16A GV Drywell Interior GV Drywell Interior GV Drywell Interior GV X-59B GV X-65B GV Drywell Interior GV X-26 GV X-59A(I

UNIT,

- 1 2 thRIO

IN=

low :

limvit A

~~

756' 756' 756' 753' 763' 767' 779' 767' 779' 767' 779' 775' 768' 767' 779' 772' 2930 2970 3010 00-2 0° to 900 900 to 1800 1800 to 2700 228o 2280 270' to 3600 780 65 65 65 65 65 66 67 68 68 68 69 69 69, -

G:\\ISI\\IWL\\outage U1-12 sched.xls Page 26 of 34 1"

1 1

1 1

1 1

1 1

..i

.p......

1n~

1 1

1 1

1 1

1 1

1 1

I.

012 012 012 012 012 013 013 013 013 013 013 L013 013

.12RIO...

Reports 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 345566 L345566 NDE-VT 003 Rev 1 N D E--VT 003 Rev 1 N D E

-VT 003 Rev 1 N-qD-E-VT 003 Rev I ND-E-VT 003 Rev I N-D-E-VT 003 Rev 1 N-D-E-VT 003 Rev 1

=NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 NDE-VT 003 Rev 1 N DE-VT 003 Rev 1 NDE-VT N-DE-VýT 1003 Rev 1 io*,b,.,,..,*.,.

-r I..- - - -

-r

-1Ia....................

I i

4iýý aiii"6i6ý 4Q

+6ýý

...* *,,'*:*,':I U-1

UNIT.

1 2 th RIO I

G:\\ISI\\IWL\\outage U1-12 sched.xls I

4, X. XI~

...S IgR........1u NDE-VT X-65A GV 768' 3050 69 1

1 1

013 345566 003 Rev 1 779'--

0°to NDE-VT Drywell Interior GV 791' 900 70 1

1 1

014 345566 003 Rev 1 779'-

90' to NDE-VT Drywell Interior GV 791' 1800 71 1

1 1

014 345566 003 Rev 1 779'-

1800 to NDE-VT Drywell Interior GV 791' 2700 72 1

1 1

014 345566 003 Rev 1 779'-

270° to NDE-VT Drywell Interior GV 791' 3600 73 1

1 1

014 345566 003 Rev 1 D791-900 74 1

11to1 150NDE-VT Drywell Interior GV 794' 900 74 1

1 1

015 345566 003 Rev 1 791'- 900 to NDE73T Drywell Interior GV 794' 1800 75 1

1 1

015 345566 003 Rev 1 791'-

1800 to NDE-VT Drywell Interior GV 794' 2700 76 1

1 1

015 345566 003 Rev 1 791'-

270' to NDE-VT Drywell Interior GV 794' 360° 77 1

1 1

015 345566 003 Rev 1 Examination Category: E-A, Containment Surfaces E1.10 Containment Vessel Pressure Retaining Boundary E1.11 Accessible Surface Areas I

Page 27 of 34

I)

Note: GV Examinations are not required below the water line (672')

Suppression Chamber 0° to Interior Floor VT-3 648' 900 1

1 1

Suppression Chamber 90° to Interior Floor VT-3 648' 1800 1

1 1

Suppression Chamber 180° to Interior Floor VT-3 648' 2700 1

1 1

Suppression Chamber 270° to Interior Floor VT-3 648' 3600 1

1 1

Suppression Chamber 648'-

0D to Interior VT-3 672' 900 104 1

1 X-206B VT-3 659' 620 104 1

1 X-234B VT-3 666' 700 104 1

1 X-235B VT-3 653' 440 104 1

1 1

X-236 VT-3 659' 490 104 1

1 1

Suppression Chamber 648-90° to Interior VT-3 672' 1800 105 1

1 X-203B VT-3 659' 1610 105 1

1 1

X-203D VT-3 659' 1390 105 1

1 1

X-209 VT-3 659' 1010 105 1

1 1

G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT'i -

2thRIO II I

I F

UcC Ucc Ucc Ucc Ucc UcC Ucc Ucc UcC Ucc Ucc Ucc UCC Ucc 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325 345325

[3453275 345325 008 Rev 0 ND -VT 008 Rev 0 ND -VT 008 Rev 0 NDE-VT 008 Rev 0 N DE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 NDE-VT 008 Rev 0 N DE-VT 008 Rev 0 D-V 008 Rev 0 NOEV-008 Rev 0 NDE-VT 008 Rev 0 ND-VT-

.008 Rev 0 Page 28 of 34 1(

I I

I)

G:\\ISl\\IWL\\outage U1-12 sched.xls UNIT 1 - 12 RIO X-214 VT-3 659' 129° 105 1

1 1

UCC 345325 008 RevO0 Suppression Chamber 648-1 to NDE-VT Interior VT-3 672' 2700 106 1

1 1

UCC 345325 008 Rev 0 ND E-VT X-203A VT-3 659' 2210° 106 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-203C VT-3 659' 1990 106 1

1 1

UCC 345325 008 Rev 0 Suppression Chamber 648'- 270° to NDE-VT Interior VT-3 672' 3600 107 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-206A VT-3 659' 2970 107 1

1 1

UCC 345325 008 Rev 0 N D E-VT X-219B VT-3 666' 2860 107 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-222 VT-3 657' 3Q07 107 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-232B VT-3 653' 2800 107 1

1 1

UCC 345325 008 Rev 0 X-237 VT-3 659' 311 ° 107 1

1 1

UCC 345325 008 RevO0 IX-243 VT-3 646' 2760 107 1

1 1

UCC 345325 008 Rev 0 Suppression Chamber 672' -

00 to:NEV Interior GV 683' 9Q0 108 1

1 1

UCC 345325 008 Rev 0 INDE-VT

!X-208B GV 673' 490 108 1

1 1

UCC 345325 008 Rev 0

  • NDE-VT X-212 GV 673' 560 108 1

1 1

UCC 345325 008 Rev 0 I

Page 29 of 34

I)

S............

ii:.............

i i~ i ii............

X.

iii
  • iii~~~iiiiiiiii iii ii ii i !

iiiii*:..,:

,.,:::...*:...:::. iii~

iii il NDE-VT X-220B GV 674' 440 108 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-224 GV 677' 770 108 1

1 1

UCC 345325 008 Rev 0 NDE-VT iX-229B GV 673' 630 108 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-234A GV 674' 710 108 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-238B GV 674' 52° 108 1

1 1

UCC 345325 008 Rev 0 Suppression Chamber 672'-

900 to NDE-VT Interior GV 683' 1800 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-210 GV 674' 1090 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-211 GV 677' 940 109 1

1 1

UCC 345325 008 RevO0 NDE-VT X-213 GV 673' 990 109 1

1 1

UCC 345325 008 RevO0 NDE-VT X-215 GV 674' 1290 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-216 GV 677' 1240 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-217 GV 673' 1220 109 1

1 1

UCC 345325 1008RevO0 NDE-VT X-225 GV 677' 1390 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-226B GV 673' 153° 109 1

1 1

UCC 345325 008 Rev 0 G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT '. 12t RIO Page 30 of 34

I4 I

G:\\ISI\\IWL\\outage U1-12 sched.xls I

th UNITi-12 RIO NDE-VT X-228D GV 673' 1020 109 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-244 GV 677' 112° 109 1

1 1

UCC 345325 008 RevO0 NDE-VT X-245 GV 673' 120° 109 1

1 1

UCC 345325 008 RevO0 NDE-VT X-246B GV 674' 167° 109 1

1 1

UCC 345325 008 Rev 0 Suppression Chamber 672'-

1800°-

NDE-VT Interior GV 683' 2700 110 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-246A GV 674' 1940 110 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-226A GV 673' 2060 110 1

1 1

UCC 345325 008 Rev 0 ND E-VT X-228C GV 673' 2350 110 1

1 1

UCC 345325 008 Rev 0 Suppression Chamber 672'-

270°-

ND E-VTI Interior GV 683' 3600 111 1

1 1

UCC 345325 008 Rev 0 N DE-VT X-231A GV 673' 276° 111 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-231B GV 673' 2820 111 1

1 1

UCC 345325 008 RevO0 N DE-VT X-230A GV 673' 2910° 111 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-229A GV 673' 2940 111 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-208A CV 673' 3110° 111 1

1 1

UCC 345325 008 RevO0 NDE-VT X-238A GV 674' 3370 111 1

1 1

UCC 345325 008 Rev 0 Page 31 of 34

UNIT.

2thRIO I

G:\\ISl\\IWL\\outage U1-12 sched.xls

!ii!!i~i~ii~iiiiiii'

.. y.............

iii!

iiiiiiiiiiii NDE-VT X-220A GV 674' 326° 111 1

1 1

UCC 345325 008 Rev 0 NDE-VT X-219A GV 674' 2860 111 1

1 1

UCC 345325 008 RevO0 Examination Category: E-A, Containment Surfaces EIA10iContainment Vessel Pressure Retaining Boundary El.20 Vent System Accessible Surface Areas Suppression Chamber Interior 660'-

NDE-VT VT-3 672' 0°-900 020/021A 1

1 1

UCC 345325 008 Rev 0 900-NDE-VT 1800 020/021A 1

1 1

UCC 345325 008 Rev0 1800-NDE-VT 2700 020/021A 1

1 1

UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1

1 1

UCC 345325 008 Rev 0 672'-

NIDE-VT VT-3 683'00-900 020/021A 1

1 1

UCC 345325 008 Rev 0 900 NDE-VT 1800 020/021A 1

1 1

UCC 345325 008 Rev 0 1800-NDE-VT 1 2700 020/021A 1

1 1

UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1

1 1

UCC 345325 008 Rev 0 Page 32 of 34

I I

G:\\ISI\\IWL\\outage U1-12 sched.xls UNIT I - f 2 th RIO 683'-

NDE-VT VT-3 700' 0o-900 020/021A 1

1 1

UCC 345325 008 Rev 0 900-NDE-VT 1800 020/021A 1

1 1

UCC 345325 008 RevO0 1800-NDE-VT 2700 020/021A 1

1 1

UCC 345325 008 Rev 0 2700-NDE-VT 3600 020/021A 1

1 1

UCC 345325 008 RevO0 Examination Category: E-G, Pressure Retaining Bolting E8.20 Bolted Connections____________

NDE-VT Personnel Hatch (X-2) VT-1 724' 1340 003A-L 1

1 016 345572 001 Rev 1 NDE-VT Equipment Hatch(X-1 VT-1 724' 3150 004-A-B 1

1 022 345572 001 Rev 1 Examination Category: L-A, Containment Surfaces L1.i10 Concrete Surfaces L1i-1. Accessible Concrete Surfaces and Coated Areas Drywell - Extekr Page 33 of 34

)

P th UNITi-12 RIO I

G:\\ISI\\IWL\\outage U1-12 sched.xls 704' -NDE-VT Concrete Surface VT-30 719' 00 90° 30 1

1 1

017 345565 003 Rev 1 90o° N DE-VT 180° 31 1

1 1

017 345565 003 Revl1 180° -

NDE-VT 2700 32 1

1 1

017 345565 003 Rev 1 270° -

NDE.-VT 3600 33 1

1 1

017 345565 003 Rev 1 1

719' -

NDE-VT VT-3C 749' Q0- 90° 34 1

1 1

018 345565 003 Rev 1 90° -

NDE-VT

__18O0° 3

1 1

1 018 34556503Re1 35 1

1TOO3Rv 1807 -

NDE-VT 2709 36 1

1 1

018 345565 003 Revl1 2700 NDE-VT 3600 37 1

1 1

018 345565 003 Revl1 749'-

NDE-VT VT-3C 779g 20 - 90° 38 1

1 1

019 345565 003 Rev 1 900" NDE-VT 1800 39 1

1 1

019 345565 003 Revl1 1800 -NDE-VT 270 3 40 1

1 1

019 345565 003 Rev 1 2700-NDE-VT 3600 41 1

1 1

019 345565 003 Rev 1 Page 34 of 34

APPENDIX G CORRECTIONS

Page 1 of 1 No corrections to previous ISI Outage Summary Reports were made.