==Dear Mr. von Suskil:==
==Dear Mr. von Suskil:==
 
We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our {{letter dated|date=March 22, 2002|text=March 22, 2002, letter}}, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.
We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our March 22, 2002, letter, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.
However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.
However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.
Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.
Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.
Sincerely,
Sincerely,
                                              /RA/
/RA/
Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page
Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page


Line 35: Line 34:


==Dear Mr. von Suskil:==
==Dear Mr. von Suskil:==
 
We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our {{letter dated|date=March 22, 2002|text=March 22, 2002, letter}}, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.
We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our March 22, 2002, letter, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.
However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.
However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.
Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.
Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.
Sincerely,
Sincerely,
                                                                    /RA/
/RA/
Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page
Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page
                      *See previous concurrence                           **No legal objection ADAMS Accession Number:ML030370752 To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosures "E" = Copy with attachments/enclosures "N =
* See previous concurrence
No copy OFFICE         INFOSEC             INFOSEC                   ADM/SB               OGC**                 OGC**
**No legal objection ADAMS Accession Number:ML030370752 To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosures "E" = Copy with attachments/enclosures "N =
NAME           JKEverly             ALSilvious*               CMStone*             DFHassell*             JRGoldberg*
No copy OFFICE INFOSEC INFOSEC ADM/SB OGC**
DATE           01/ 30/03           01/02/03                   01/02/03             12/16/02               12/16/02 OFFICE         DLPM/PM           DLPM/LA               D/DLPM           D/DFS             D/NSIR               D/ADM NAME           BMoroney         CRosenberg           JAZwolinski* TOMartin*             RPZimmerman* MLSpringer DATE           01/29/03         01/29/03             01/13/03         01/13/03         01/14/03             01/ 31/03 OFFICIAL RECORD COPY
OGC**
NAME JKEverly ALSilvious*
CMStone*
DFHassell*
JRGoldberg*
DATE 01/ 30/03 01/02/03 01/02/03 12/16/02 12/16/02 OFFICE DLPM/PM DLPM/LA D/DLPM D/DFS D/NSIR D/ADM NAME BMoroney CRosenberg JAZwolinski* TOMartin*
RPZimmerman*
MLSpringer DATE 01/29/03 01/29/03 01/13/03 01/13/03 01/14/03 01/ 31/03 OFFICIAL RECORD COPY


DISTRIBUTION (Letter to licensees regarding submittal of FOCI information)
DISTRIBUTION (Letter to licensees regarding submittal of FOCI information)
Line 51: Line 56:


Braidwood Station Units 1 and 2 cc:
Braidwood Station Units 1 and 2 cc:
Regional Administrator, Region III   Illinois Emergency Management U.S. Nuclear Regulatory Commission     Agency 801 Warrenville Road                 Division of Disaster Assistance &
Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, IL 62704 Document Control Desk-Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Ms. C. Sue Hauser, Project Manager Westinghouse Electric Corporation Energy Systems Business Unit Post Office Box 355 Pittsburgh, PA 15230 Joseph Gallo Gallo & Ross 1025 Connecticut Ave., NW, Suite 1014 Washington, DC 20036 Ms. Bridget Little Rorem Appleseed Coordinator 117 N. Linden Street Essex, IL 60935 Howard A. Learner Environmental Law and Policy Center of the Midwest 35 East Wacker Dr., Suite 1300 Chicago, IL 60601-2110 U.S. Nuclear Regulatory Commission Braidwood Resident Inspectors Office 35100 S. Rt. 53, Suite 79 Braceville, IL 60407 Ms. Lorraine Creek RR 1, Box 182 Manteno, IL 60950 Illinois Emergency Management Agency Division of Disaster Assistance &
Lisle, IL 60532-4351                   Preparedness 110 East Adams Street Illinois Department of Nuclear Safety Springfield, IL 62701-1109 Office of Nuclear Facility Safety 1035 Outer Park Drive                 Chairman Springfield, IL 62704                 Will County Board of Supervisors Will County Board Courthouse Document Control Desk-Licensing       Joliet, IL 60434 Exelon Generation Company, LLC 4300 Winfield Road                   Attorney General Warrenville, IL 60555                 500 S. Second Street Springfield, IL 62701 Ms. C. Sue Hauser, Project Manager Westinghouse Electric Corporation     George L. Edgar Energy Systems Business Unit         Morgan, Lewis and Bockius Post Office Box 355                   1800 M Street, NW Pittsburgh, PA 15230                 Washington, DC 20036-5869 Joseph Gallo                         Braidwood Station Manager Gallo & Ross                         Exelon Generation Company, LLC 1025 Connecticut Ave., NW, Suite 1014 35100 S. Rt. 53, Suite 84 Washington, DC 20036                 Braceville, IL 60407-9619 Ms. Bridget Little Rorem             Senior Vice President, Nuclear Services Appleseed Coordinator                 Exelon Generation Company, LLC 117 N. Linden Street                 4300 Winfield Road Essex, IL 60935                       Warrenville, IL 60555 Howard A. Learner                     Vice President Environmental Law and Policy         Mid-West Operations Support Center of the Midwest               Exelon Generation Company, LLC 35 East Wacker Dr., Suite 1300       4300 Winfield Road Chicago, IL 60601-2110               Warrenville, IL 60555 U.S. Nuclear Regulatory Commission   Chairman, Ogle County Board Braidwood Resident Inspectors Office Post Office Box 357 35100 S. Rt. 53, Suite 79             Oregon, IL 61061 Braceville, IL 60407 Ms. Lorraine Creek RR 1, Box 182 Manteno, IL 60950
Preparedness 110 East Adams Street Springfield, IL 62701-1109 Chairman Will County Board of Supervisors Will County Board Courthouse Joliet, IL 60434 Attorney General 500 S. Second Street Springfield, IL 62701 George L. Edgar Morgan, Lewis and Bockius 1800 M Street, NW Washington, DC 20036-5869 Braidwood Station Manager Exelon Generation Company, LLC 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Senior Vice President, Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President Mid-West Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Chairman, Ogle County Board Post Office Box 357 Oregon, IL 61061


Braidwood Station Units 1 and 2             Exelon Generation Company, LLC                   Mr. John L. Skolds, President Regulatory Assurance Manager - Braidwood         Exelon Nuclear 35100 S. Rt. 53, Suite 84                         Exelon Generation Company, LLC Braceville, IL 60407-9619                         4300 Winfield Road Warrenville, IL 60555 Senior Vice President Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Counsel, Nuclear Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing Braidwood and Byron Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555}}
Braidwood Station Units 1 and 2 Exelon Generation Company, LLC Regulatory Assurance Manager - Braidwood 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Senior Vice President Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Counsel, Nuclear Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing Braidwood and Byron Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555}}

Latest revision as of 12:34, 16 January 2025

Foreign Ownership, Control, or Influence Information
ML030370752
Person / Time
Site: Braidwood  
Issue date: 01/31/2003
From: Springer M
Office of Administration
To: Vonsuskil J
Exelon Generation Co
Moroney B, NRR/DLPM, 415-3974
References
Download: ML030370752 (6)


Text

January 31, 2003 Mr. James D. von Suskil, Site Vice President Braidwood Station, Units 1 & 2 Exelon Generation Company, LLC 35100 S. Rt. 53, Suite 84 Braceville, Il 60407

SUBJECT:

BRAIDWOOD STATION, UNITS 1& 2 - FOREIGN OWNERSHIP, CONTROL, OR INFLUENCE INFORMATION

Dear Mr. von Suskil:

We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our March 22, 2002, letter, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.

However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.

Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.

Sincerely,

/RA/

Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page

January 31, 2003 Mr. James D. von Suskil, Site Vice President Braidwood Station, Units 1 & 2 Exelon Generation Company, LLC 35100 S. Rt. 53, Suite 84 Braceville, Il 60407

SUBJECT:

BRAIDWOOD STATION, UNITS 1& 2 - FOREIGN OWNERSHIP, CONTROL, OR INFLUENCE INFORMATION

Dear Mr. von Suskil:

We are writing to advise you that your company has not yet submitted its Foreign Ownership, Control, or Influence (FOCI) information that was outlined in our letter of March 22, 2002. As you may recall, the Nuclear Regulatory Commission (NRC) is taking steps to enhance its licensees ability to respond to the continuing heightened security environment by processing personnel security clearances for licensees. In order for the NRC to grant the personnel security clearances that your company requested subsequent to our March 22, 2002, letter, we must first make a Facility Security Clearance determination based on the FOCI information you submit. Currently, the NRC is authorized to disseminate classified information to uncleared persons only under special circumstances when timeliness is critical to mitigating an emergency situation. Under our new clearance program, licensees may have access to classified information under more routine circumstances once personnel security clearances are granted.

However, before we can grant personnel security clearances, the NRC needs to make a successful FOCI determination, which may require several months to complete. Therefore, it is imperative that you provide your FOCI information to us as soon as possible. If you need to review the regulations on FOCI and Facility Security Clearance requirements, an overview can be found in Part 95 of Title 10 of the Code of Federal Regulations.

Questions regarding FOCI packages should be referred to J. Keith Everly of the Office of Nuclear Security and Incident Response at 301-415-7048 or jke@nrc.gov.

Sincerely,

/RA/

Michael L. Springer, Director Office of Administration Docket No(s): 50-456 and 50-457 cc: See next page

  • See previous concurrence
    • No legal objection ADAMS Accession Number:ML030370752 To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosures "E" = Copy with attachments/enclosures "N =

No copy OFFICE INFOSEC INFOSEC ADM/SB OGC**

OGC**

NAME JKEverly ALSilvious*

CMStone*

DFHassell*

JRGoldberg*

DATE 01/ 30/03 01/02/03 01/02/03 12/16/02 12/16/02 OFFICE DLPM/PM DLPM/LA D/DLPM D/DFS D/NSIR D/ADM NAME BMoroney CRosenberg JAZwolinski* TOMartin*

RPZimmerman*

MLSpringer DATE 01/29/03 01/29/03 01/13/03 01/13/03 01/14/03 01/ 31/03 OFFICIAL RECORD COPY

DISTRIBUTION (Letter to licensees regarding submittal of FOCI information)

PUBLIC DCF: LRD 3.00.09 LRD 7.00.09 P.G. Norry, EDO S. A. Morris, EDO S.J. Collins, NRR B.W. Sheron, NRR J.A. Zwolinski/ Tad Marsh, NRR B.A. Boger, NRR R. P. Zimmerman, NSIR M. F. Weber, NSIR G. M. Tracy, D/DNS M.L. Springer, D/ADM T.O. Martin, D/DFS J. K. Everly, NSIR ADM R/F DFS R/F INFOSEC R/F PDIII-2 R/F L. Ragavan A. Mendiola M. Chawla C. Rosenberg A. Stone, RIII ACRS OGC

Braidwood Station Units 1 and 2 cc:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, IL 62704 Document Control Desk-Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Ms. C. Sue Hauser, Project Manager Westinghouse Electric Corporation Energy Systems Business Unit Post Office Box 355 Pittsburgh, PA 15230 Joseph Gallo Gallo & Ross 1025 Connecticut Ave., NW, Suite 1014 Washington, DC 20036 Ms. Bridget Little Rorem Appleseed Coordinator 117 N. Linden Street Essex, IL 60935 Howard A. Learner Environmental Law and Policy Center of the Midwest 35 East Wacker Dr., Suite 1300 Chicago, IL 60601-2110 U.S. Nuclear Regulatory Commission Braidwood Resident Inspectors Office 35100 S. Rt. 53, Suite 79 Braceville, IL 60407 Ms. Lorraine Creek RR 1, Box 182 Manteno, IL 60950 Illinois Emergency Management Agency Division of Disaster Assistance &

Preparedness 110 East Adams Street Springfield, IL 62701-1109 Chairman Will County Board of Supervisors Will County Board Courthouse Joliet, IL 60434 Attorney General 500 S. Second Street Springfield, IL 62701 George L. Edgar Morgan, Lewis and Bockius 1800 M Street, NW Washington, DC 20036-5869 Braidwood Station Manager Exelon Generation Company, LLC 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Senior Vice President, Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President Mid-West Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Chairman, Ogle County Board Post Office Box 357 Oregon, IL 61061

Braidwood Station Units 1 and 2 Exelon Generation Company, LLC Regulatory Assurance Manager - Braidwood 35100 S. Rt. 53, Suite 84 Braceville, IL 60407-9619 Senior Vice President Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director Licensing Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Counsel, Nuclear Mid-West Regional Operating Group Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing Braidwood and Byron Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Mr. John L. Skolds, President Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555