ML042080249: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 2: | Line 2: | ||
| number = ML042080249 | | number = ML042080249 | ||
| issue date = 07/22/2004 | | issue date = 07/22/2004 | ||
| title = Transmittal of Interim Report Concerning an Evaluation of a Deviation Pursuant to 10CFR21.21 (a)(2) | | title = Transmittal of Interim Report Concerning an Evaluation of a Deviation Pursuant to 10CFR21.21 (a)(2) | ||
| author name = Mallay J | | author name = Mallay J | ||
| author affiliation = Framatome ANP, Inc | | author affiliation = Framatome ANP, Inc | ||
| Line 16: | Line 16: | ||
=Text= | =Text= | ||
{{#Wiki_filter:A FRAMATOME ANP | {{#Wiki_filter:A FRAMATOME ANP An AREVA and Siemens Company FRAMATOME ANP, Inc. | ||
July 22, 2004 NRC:04:036 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Interim Report Concerning an Evaluation of a Deviation Pursuant to I OCFR21.21 (a)(2) | July 22, 2004 NRC:04:036 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Interim Report Concerning an Evaluation of a Deviation Pursuant to I OCFR21.21 (a)(2) | ||
Ref.: 1. Letter, James F. Mallay (Framatome ANP) to Document Control Desk (NRC), | Ref.: 1. Letter, James F. Mallay (Framatome ANP) to Document Control Desk (NRC), | ||
"Deviation Associated with Swelling in Certain Control Rods," NRC:04:026, May 25, 2004. | |||
Enclosed is an interim report concerning an evaluation of a deviation under the provisions of Part 21. | Enclosed is an interim report concerning an evaluation of a deviation under the provisions of Part 21. | ||
Framatome ANP previously reported in Reference 1 that an evaluation had been initiated to determine the adequacy of its model to predict the swelling behavior of absorber material in certain control assemblies. Specifically, the purpose of the evaluation is to establish a conservative, safe, service lifetime of the extended life control rod assemblies used in B&W-designed plants. | Framatome ANP previously reported in Reference 1 that an evaluation had been initiated to determine the adequacy of its model to predict the swelling behavior of absorber material in certain control assemblies. Specifically, the purpose of the evaluation is to establish a conservative, safe, service lifetime of the extended life control rod assemblies used in B&W-designed plants. | ||
| Line 25: | Line 25: | ||
The enclosed report summarizes the actions being taken to assess the behavior of the silver-indium-cadmium absorber and whether swelling could be a concern over the next several years. | The enclosed report summarizes the actions being taken to assess the behavior of the silver-indium-cadmium absorber and whether swelling could be a concern over the next several years. | ||
No customer has observed or reported any adverse experience with the control assemblies supplied by Framatome ANP. Since none of the control assemblies are approaching their original design lifetime, there is no reason to believe a substantial safety hazard exists. | No customer has observed or reported any adverse experience with the control assemblies supplied by Framatome ANP. Since none of the control assemblies are approaching their original design lifetime, there is no reason to believe a substantial safety hazard exists. | ||
Very truly yours, ames . allay, Director Regulatory Affairs Enclosure cc: | Very truly yours, ames. | ||
3315 Old Forest Road, P.O. Box 10935 - Lynchburg, VA 24506-0935 Tel.: 434-832-3000 Fax: 434-832-0622 www.us.framatome-anp.com | allay, Director Regulatory Affairs Enclosure cc: | ||
M. C. Honcharik Project 728 FRAMATOME ANP, Inc. | |||
3315 Old Forest Road, P.O. Box 10935 - Lynchburg, VA 24506-0935 Tel.: 434-832-3000 Fax: 434-832-0622 www.us.framatome-anp.com Te-2'}} | |||
Latest revision as of 02:12, 16 January 2025
| ML042080249 | |
| Person / Time | |
|---|---|
| Site: | Oconee, PROJ0728 |
| Issue date: | 07/22/2004 |
| From: | Mallay J Framatome ANP |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NRC-04-036 | |
| Download: ML042080249 (1) | |
Text
A FRAMATOME ANP An AREVA and Siemens Company FRAMATOME ANP, Inc.
July 22, 2004 NRC:04:036 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Interim Report Concerning an Evaluation of a Deviation Pursuant to I OCFR21.21 (a)(2)
Ref.: 1. Letter, James F. Mallay (Framatome ANP) to Document Control Desk (NRC),
"Deviation Associated with Swelling in Certain Control Rods," NRC:04:026, May 25, 2004.
Enclosed is an interim report concerning an evaluation of a deviation under the provisions of Part 21.
Framatome ANP previously reported in Reference 1 that an evaluation had been initiated to determine the adequacy of its model to predict the swelling behavior of absorber material in certain control assemblies. Specifically, the purpose of the evaluation is to establish a conservative, safe, service lifetime of the extended life control rod assemblies used in B&W-designed plants.
This same model will also be used to assess the useful life of the rod cluster control assemblies provided by Framatome ANP to Westinghouse-designed plants as replacements for the original control assemblies. Since the current exposure of these RCCAs is much less than the ELCRAs, they will not be affected by any model change for a number of years.
The enclosed report summarizes the actions being taken to assess the behavior of the silver-indium-cadmium absorber and whether swelling could be a concern over the next several years.
No customer has observed or reported any adverse experience with the control assemblies supplied by Framatome ANP. Since none of the control assemblies are approaching their original design lifetime, there is no reason to believe a substantial safety hazard exists.
Very truly yours, ames.
allay, Director Regulatory Affairs Enclosure cc:
M. C. Honcharik Project 728 FRAMATOME ANP, Inc.
3315 Old Forest Road, P.O. Box 10935 - Lynchburg, VA 24506-0935 Tel.: 434-832-3000 Fax: 434-832-0622 www.us.framatome-anp.com Te-2'