{{#Wiki_filter:Entergy Nuclear Operations, Inc.
{{#Wiki_filter:Entergy Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant Entergy                                                    27780 Blue Star Memorial Highway Covert, MI 49043-9530 Tel 269 764 2000 Jeffery A. Hardy Regulatory Assurance Manager PNP 2015-010 March 04, 2015 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530 Tel 269 764 2000 Jeffery A. Hardy Regulatory Assurance Manager PNP 2015-010 March 04, 2015 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001


==SUBJECT:==
==SUBJECT:==
Line 30: Line 30:


==Dear Sir or Madam:==
==Dear Sir or Madam:==
Entergy Nuclear Operations, Inc. (ENO) submitted Reference 1 to the Nuclear Regulatory Commission (NRC) providing the results of steam generator tube inspections conducted during the 2014 Palisades Nuclear Plant (PNP) refueling outage.
Entergy Nuclear Operations, Inc. (ENO) submitted Reference 1 to the Nuclear Regulatory Commission (NRC) providing the results of steam generator tube inspections conducted during the 2014 Palisades Nuclear Plant (PNP) refueling outage.
ENO received an electronic request for additional information (RAI) from the NRC in Reference 2. ENO and the NRC held a conference call on December 16, 2014 to clarify the RAI.
ENO received an electronic request for additional information (RAI) from the NRC in Reference 2. ENO and the NRC held a conference call on December 16, 2014 to clarify the RAI.
Line 37: Line 36:
Sincerely, jah/jpm
Sincerely, jah/jpm


PNP 2015-010 Page 2 of 2 : Response to "Request for Additional Information Regarding the January-February 2014 Steam Generator Tube Inspections" : Errata Information, "Replacement Information for the Palisades Nuclear Plant Steam Generator Tube Inspection Report for the 2014 Refueling Outage, 1R23" cc:   Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC
PNP 2015-010 Page 2 of 2 : Response to "Request for Additional Information Regarding the January-February 2014 Steam Generator Tube Inspections" : Errata Information, "Replacement Information for the Palisades Nuclear Plant Steam Generator Tube Inspection Report for the 2014 Refueling Outage, 1 R23" cc:
Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC


ATTACHMENT 1 RESPONSE TO "REQUEST FOR ADDITIONAL INFORMATION REGARDING THE JANUARY-FEBRUARY 2014 STEAM GENERATOR TUBE INSPECTIONS" A request for additional information (RAI) regarding the January-February 2014 Steam Generator Tube Inspections Palisades Nuclear Plant Docket No. 50-255 was received by electronic mail on December 16, 2014.
ATTACHMENT 1 RESPONSE TO "REQUEST FOR ADDITIONAL INFORMATION REGARDING THE JANUARY-FEBRUARY 2014 STEAM GENERATOR TUBE INSPECTIONS" A request for additional information (RAI) regarding the January-February 2014 Steam Generator Tube Inspections Palisades Nuclear Plant Docket No. 50-255 was received by electronic mail on December 16, 2014.
By letter dated August 5, 2014 (Agency wide Documents Access and Management System (ADAMS) Accession No. ML14218A548), Entergy Nuclear Operations, Inc. (the licensee) submitted information summarizing the results of the 2014 steam generator tube inspections performed at Palisades Nuclear Plant. These inspections were performed during refueling outage 23 in January-February, 2014. In a letter dated April 30, 2014 (ADAMS Accession No. ML14093A243), the U.S. Nuclear Regulatory Commission (NRC) staff summarized a conference call with the licensee regarding the January-February 2014 steam generator tube inspections. The NRC staff reviewed the information provided and determined that additional information is required in order to complete its review.
By {{letter dated|date=August 5, 2014|text=letter dated August 5, 2014}} (Agency wide Documents Access and Management System (ADAMS) Accession No. ML14218A548), Entergy Nuclear Operations, Inc. (the licensee) submitted information summarizing the results of the 2014 steam generator tube inspections performed at Palisades Nuclear Plant. These inspections were performed during refueling outage 23 in January-February, 2014. In a {{letter dated|date=April 30, 2014|text=letter dated April 30, 2014}} (ADAMS Accession No. ML14093A243), the U.S. Nuclear Regulatory Commission (NRC) staff summarized a conference call with the licensee regarding the January-February 2014 steam generator tube inspections. The NRC staff reviewed the information provided and determined that additional information is required in order to complete its review.
Nuclear Regulatory Commission (NRC) Request
Nuclear Regulatory Commission (NRC) Request
: 1. There are several instances in the report where it does not appearthe results were properly communicated and/or the technical details were not fully understood. Please clarify the following:
: 1. There are several instances in the report where it does not appear the results were properly communicated and/or the technical details were not fully understood. Please clarify the following:
: a. Item "g"on page 3 of 156 indicates, in part, that the results of the condition monitoring are provided in Table 6. Table 6 does not have the indicatedinformation; however, it appearsthe results are provided further down on the page.
: a. Item "g" on page 3 of 156 indicates, in part, that the results of the condition monitoring are provided in Table 6. Table 6 does not have the indicated information; however, it appears the results are provided further down on the page.
ENO Response
ENO Response
: a. Items "a" through "h" listed in page 3 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" are quoted from Palisades Technical Specification Section 5.6.8, "Steam Generator Tube Inspection Report," with the addition of report table references in parenthesis. Entergy Nuclear Operations, Inc. (ENO) revised Item "g" to clarify that table 6 includes the as found condition of tubes that were plugged and that the remaining condition monitoring results are provided in the body of the report. The revised wording is provided below and in Attachment 2 to this RAI response.
: a. Items "a" through "h" listed in page 3 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" are quoted from Palisades Technical Specification Section 5.6.8, "Steam Generator Tube Inspection Report," with the addition of report table references in parenthesis. Entergy Nuclear Operations, Inc. (ENO) revised Item "g" to clarify that table 6 includes the as found condition of tubes that were plugged and that the remaining condition monitoring results are provided in the body of the report. The revised wording is provided below and in Attachment 2 to this RAI response.
Page 1 of 6
Page 1 of 6


      "g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6- as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below),
"g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6-as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below),
and" NRC Request In addition, on page 3 of 156 there is a discussion about the accident induced leakage performance criteria. The following statements were made:
and" NRC Request In addition, on page 3 of 156 there is a discussion about the accident induced leakage performance criteria. The following statements were made:
Leakage did not exceed the 0.3 gallon per minute (gpm) accident induced leakage limit. Primary-to-secondaryleak rate measured using condenser off-gas (Xenon-135) was measured at 0.0003 gpm for the start of operating cycle 23, finished at <0.0001 gpm and had a decreasingtrend over the cycle.
Leakage did not exceed the 0.3 gallon per minute (gpm) accident induced leakage limit. Primary-to-secondary leak rate measured using condenser off-gas (Xenon-135) was measured at 0.0003 gpm for the start of operating cycle 23, finished at <0.0001 gpm and had a decreasing trend over the cycle.
No leakage was predictedfor either operatingor accident conditions for the 2012 to 2014 operatingcycle due to observed SG tube degradationin the 2014 refueling outage. All plugs installed were Alloy 690 in the PalisadesSGs post-operationand are either Westinghouse ribbed mechanicalplugs or Areva mechanically rolled plugs. The Westinghouse plugs are leak-tight for all plant conditions.
No leakage was predicted for either operating or accident conditions for the 2012 to 2014 operating cycle due to observed SG tube degradation in the 2014 refueling outage. All plugs installed were Alloy 690 in the Palisades SGs post-operation and are either Westinghouse ribbed mechanical plugs or Areva mechanically rolled plugs. The Westinghouse plugs are leak-tight for all plant conditions.
The Areva roll expansion provides a leak-limiting seal between the plug and tube wall.
The Areva roll expansion provides a leak-limiting seal between the plug and tube wall.
Accident induced leakage is the primary-to-secondaryleakage that occurs during a design basis accident. As a result, this value is calculatedbased, in part, on inspection results. Other sources of accident induced primary-to-secondaryleakage are leakage past plugs and other repairs. In addition, implementation of alternate repaircriteria may also be a source of accident induced leakage particularlywhen the criteria eliminates the need to inspect certain locations of the tube.
Accident induced leakage is the primary-to-secondary leakage that occurs during a design basis accident. As a result, this value is calculated based, in part, on inspection results. Other sources of accident induced primary-to-secondary leakage are leakage past plugs and other repairs. In addition, implementation of alternate repair criteria may also be a source of accident induced leakage particularly when the criteria eliminates the need to inspect certain locations of the tube.
: 1)   Therefore, please clarify whether or not the first sentence in the above quote was intended to indicate that the calculatedleakage from all potentialsources of accident induced leakage did not exceed the 0.3 gpm accident induced leakage limit.
: 1)
: 2)   Please confirm that the second sentence in the above quote was simply a statement regardingoperationalleakage.
Therefore, please clarify whether or not the first sentence in the above quote was intended to indicate that the calculated leakage from all potential sources of accident induced leakage did not exceed the 0.3 gpm accident induced leakage limit.
: 3)   Please clarify that the third sentence in the above quote only includes the contribution to the accidentinduced leakage associated with the observed degradationmechanisms.
: 2)
Please confirm that the second sentence in the above quote was simply a statement regarding operational leakage.
: 3)
Please clarify that the third sentence in the above quote only includes the contribution to the accident induced leakage associated with the observed degradation mechanisms.
Page 2 of 6
Page 2 of 6
: 4)   Please confirm that the accidentinduced leakage associated with the Areva roll expanded plugs (i.e., leak limiting plugs) was combined with the accident induced leakage associated with implementation of the C* alternate repaircriteriaand the accident induced leakage from all other sources (presumablyzero for the observed degradationmechanisms based on the third sentence in the above quote) for comparison againstthe 0.3 gpm accident induced leakage limit.
: 4)
Please confirm that the accident induced leakage associated with the Areva roll expanded plugs (i.e., leak limiting plugs) was combined with the accident induced leakage associated with implementation of the C* alternate repair criteria and the accident induced leakage from all other sources (presumably zero for the observed degradation mechanisms based on the third sentence in the above quote) for comparison against the 0.3 gpm accident induced leakage limit.
ENO Response
ENO Response
: 1)   Yes, the first sentence was intended, in summary, to indicate that leakage from all potential sources was included in the calculation of accident induced leakage and the resultant value did not exceed the 0.3 gpm accident induced leakage limit.
: 1)
: 2)   Yes, the second sentence is a statement of operational leakage over the 2012 to 2014 operating cycle.
Yes, the first sentence was intended, in summary, to indicate that leakage from all potential sources was included in the calculation of accident induced leakage and the resultant value did not exceed the 0.3 gpm accident induced leakage limit.
: 3)   Yes, the third sentence was intended to state the accident induced leakage contribution associated with the 2014 refueling outage inspection's observed steam generator (SG) tube degradation mechanisms only.
: 2)
: 4)   Yes, the accident induced leakage calculation did include predicted leakage from Areva roll expanded plugs (i.e., leak limiting plugs),
Yes, the second sentence is a statement of operational leakage over the 2012 to 2014 operating cycle.
: 3)
Yes, the third sentence was intended to state the accident induced leakage contribution associated with the 2014 refueling outage inspection's observed steam generator (SG) tube degradation mechanisms only.
: 4)
Yes, the accident induced leakage calculation did include predicted leakage from Areva roll expanded plugs (i.e., leak limiting plugs),
implementation of C* alternative repair criteria, and all other potential sources for comparison against the 0.3 gpm accident induced leakage limit.
implementation of C* alternative repair criteria, and all other potential sources for comparison against the 0.3 gpm accident induced leakage limit.
NRC Request
NRC Request
: b. Please clarify that Tables 4A, 4B, and 4C provide all of the service induced indications. If not, please provide any service induced indicationsnot included in those tables (e.g., the wear indications associatedwith possible loose parts). Please ensure the location, orientation (if linear), and measured sizes (if available)of all service induced indicationsare provided (since it does not appearthat such information was provided for some of the indicationssuch as wear associatedwith possible loose parts). The staff notes that the statements that "Table 4A provides the location and measured sizes of service induced indications"and the majority "area result of axial and circumferentialoutside diameter stress corrosioncracking"indicationsis misleading since Table 4A only provides a subset of service induced indicationsand only includes axial and circumferentialoutside diameter stress corrosion cracking indications.
: b.
Please clarify that Tables 4A, 4B, and 4C provide all of the service induced indications. If not, please provide any service induced indications not included in those tables (e.g., the wear indications associated with possible loose parts). Please ensure the location, orientation (if linear), and measured sizes (if available) of all service induced indications are provided (since it does not appear that such information was provided for some of the indications such as wear associated with possible loose parts). The staff notes that the statements that "Table 4A provides the location and measured sizes of service induced indications" and the majority "are a result of axial and circumferential outside diameter stress corrosion cracking" indications is misleading since Table 4A only provides a subset of service induced indications and only includes axial and circumferential outside diameter stress corrosion cracking indications.
Page 3 of 6
Page 3 of 6


ENO Response
ENO Response
: b. Additional information was added to Table 4A to include volumetric indications with loose parts present. Page 4 and 16 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised. The revised wording is provided below and in Attachment 2 of this RAI response.
: b.
Additional information was added to Table 4A to include volumetric indications with loose parts present. Page 4 and 16 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised. The revised wording is provided below and in Attachment 2 of this RAI response.
Page 4, "Service Induced Indications,"
Page 4, "Service Induced Indications,"
There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes were affected by this part.
There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes were affected by this part.
Page 16, "Table 4A,"
Page 16, "Table 4A,"
Volumetric Indications with Loose Part Present NDE Sizing Maximum   Circumferential NDE Axial SG   Row   Col. Location   ETSS     (%Dp)   Length (deg.) Length (in.)
Volumetric Indications with Loose Part Present NDE Sizing Maximum Circumferential NDE Axial SG Row Col.
Location ETSS
(%Dp)
Length (deg.)
Length (in.)
(Note 1)
(Note 1)
SG                 TSH A   133     74   400     27901.1       37         58 A                 +0.0i                                         0.33 SG                   TSH A
SG TSH A
rT SC 134   75   +00     27901.1       51         70 A                 +0.00                                         0.30 SG B
133 74 400 27901.1 37 58 0.33 A  
I 108     35   +0.00 t111 10908.4       11         54           0.23 Nuclear Regulatory Commission (NRC) Request
+0.0i SG TSH A
: c. Please confirm that the tubes in SG A row 134, column 75 and SG A row 133, column 74 had wear attributed to a loose part since the last sentence indicates that "these tubes had no wear indicationsfrom the loose part." It was not clear which tubes were being referred to by the reference to "these tubes."
134 75  
+00 27901.1 51 70 0.30 A  
+0.00 SG I rT SC t111 B
108 35  
+0.00 10908.4 11 54 0.23 Nuclear Regulatory Commission (NRC) Request
: c.
Please confirm that the tubes in SG A row 134, column 75 and SG A row 133, column 74 had wear attributed to a loose part since the last sentence indicates that "these tubes had no wear indications from the loose part." It was not clear which tubes were being referred to by the reference to "these tubes."
ENO Response
ENO Response
: c. Page 4 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised to clarify that "these tubes" is referring to SG A Row 134 Column 75 and SG A Row 133 Column 74. The revised wording is provided below and in Attachment 2 to this RAI response.
: c.
Page 4 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised to clarify that "these tubes" is referring to SG A Row 134 Column 75 and SG A Row 133 Column 74. The revised wording is provided below and in to this RAI response.
Page 4 of 6
Page 4 of 6


        "There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future."
"There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future."
NRC Request
NRC Request
: d. The headings for the tables on pages 152 through 156 reference the 2012 refueling outage. Please clarify.
: d.
The headings for the tables on pages 152 through 156 reference the 2012 refueling outage. Please clarify.
ENO Response
ENO Response
: d. The headings for the tables on pages 153 through 156 have been revised in "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1R23" to reference 2014 rather than 2012. The revised wording is provided in Attachment 2 to this RAI response.
: d.
The headings for the tables on pages 153 through 156 have been revised in "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" to reference 2014 rather than 2012. The revised wording is provided in Attachment 2 to this RAI response.
Note that due to other document revisions and formatting the above referenced page numbers have been revised to pages 153 through 156.
Note that due to other document revisions and formatting the above referenced page numbers have been revised to pages 153 through 156.
NRC Request
NRC Request
: 2. Please discuss the nature of the restriction in the tube in row 3, column 112 in steam generatorE-50B. For example, has the condition changed with time?
: 2. Please discuss the nature of the restriction in the tube in row 3, column 112 in steam generator E-50B. For example, has the condition changed with time?
ENO Response
ENO Response
: 2. Page 4 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised better describe the nature of the restriction in row 3, column 112. The revised wording is provided below and in Attachment 2 to this RAI response.
: 2.
  "Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of Page 5 of 6
Page 4 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised better describe the nature of the restriction in row 3, column 112. The revised wording is provided below and in Attachment 2 to this RAI response.
"Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of Page 5 of 6


SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1R21, 1 R22, and 1R23 inspections."
SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1 R21, 1 R22, and 1 R23 inspections."
NRC Request
NRC Request
: 3. Please summarize the number of indicationsof wear detected and how many tubes are affected (e.g., 10 indications of wear at the eggcrate supports in 8 tubes, 35 indicationsof wear at the diagonalbars in 22 tubes, etc.).
: 3. Please summarize the number of indications of wear detected and how many tubes are affected (e.g., 10 indications of wear at the eggcrate supports in 8 tubes, 35 indications of wear at the diagonal bars in 22 tubes, etc.).
ENO Response
ENO Response
: 3. Table 4D "Wear Indication Summary" was added to page 152 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1R23". The new table is provided below and in Attachment 2 to this RAI response.
: 3. Table 4D "Wear Indication Summary" was added to page 152 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23". The new table is provided below and in to this RAI response.
Table 4D Wear Indication Summary Diagonal Bar Wear   Vertical Strap Wear   Eggcrate Wear     Foreign Object Wear Tubes   Indications Tubes   Indications Tubes   Indications Tubes   Indications SGA       175       184       473         787     1387     1949       3           3 SGB       131       137       515         842     1085     1372       2           3 NRC Request
Table 4D Wear Indication Summary Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear Foreign Object Wear Tubes Indications Tubes Indications Tubes Indications Tubes Indications SGA 175 184 473 787 1387 1949 3
: 4. Please discuss whether an inspection of the plugs was performed. If so, please discuss the results of the inspection (e.g., all plugs were present in the properlocation and no degradationwas observed).
3 SGB 131 137 515 842 1085 1372 2
3 NRC Request
: 4. Please discuss whether an inspection of the plugs was performed. If so, please discuss the results of the inspection (e.g., all plugs were present in the proper location and no degradation was observed).
ENO Response
ENO Response
: 4. Page 4 paragraph 1 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1R23" was revised discuss the visual inspection that was performed on the tube plugs. The revised wording is provided below and in Attachment 2 to this RAI response.
: 4.
    "A 100% visual inspection of the previously installed plugs was performed with no anomalies identified. Plug location was also verified."
Page 4 paragraph 1 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised discuss the visual inspection that was performed on the tube plugs. The revised wording is provided below and in Attachment 2 to this RAI response.
"A 100% visual inspection of the previously installed plugs was performed with no anomalies identified. Plug location was also verified."
Page 6 of 6
Page 6 of 6


Line 115: Line 142:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE INSPECTION REPORT for the 2014 REFUELING OUTAGE, 1R23 EC 54968 1 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE INSPECTION REPORT for the 2014 REFUELING OUTAGE, 1R23 EC 54968 1 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage TABLE OF CONTENTS Inspection Summary                                                     3 Table A Refueling Outage (RFO) Information since Steam Generator Replacement                                                           6 Table 1   Scope and Extent of Tubes Inspected                         7 Table 2   Active Damage Mechanisms                                     7 Table 3   Eddy Current Techniques                                     8 Table 4A Location and Measured Sizes of Service Induced Indications   14 Table 4B Steam Generator E-50A Indications                             17 Table 4C Steam Generator E-50B Indications                             92 Table 4D Wear Indication Summary                                       152 Table 5   Tube Plugging Summary by Damage Mechanism                   153 Table 6   Condition Monitoring Results Identification of Tubes Plugged 154 Table 7A Steam Generator Support Structure Nomenclature               155 Table 7B Acronyms and Abbreviations                                   156 2 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage TABLE OF CONTENTS Inspection Summary 3
Table A Refueling Outage (RFO) Information since Steam Generator Replacement 6
Table 1 Scope and Extent of Tubes Inspected 7
Table 2 Active Damage Mechanisms 7
Table 3 Eddy Current Techniques 8
Table 4A Location and Measured Sizes of Service Induced Indications 14 Table 4B Steam Generator E-50A Indications 17 Table 4C Steam Generator E-50B Indications 92 Table 4D Wear Indication Summary 152 Table 5 Tube Plugging Summary by Damage Mechanism 153 Table 6 Condition Monitoring Results Identification of Tubes Plugged 154 Table 7A Steam Generator Support Structure Nomenclature 155 Table 7B Acronyms and Abbreviations 156 2 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Inspection Summary Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports, requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report shall include:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Inspection Summary Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports, requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report shall include:
Line 124: Line 156:
: e. Number of tubes plugged during the inspection outage for each active degradation mechanism (Table 5),
: e. Number of tubes plugged during the inspection outage for each active degradation mechanism (Table 5),
: f. Total number and percentage of tubes plugged to date (Table 5),
: f. Total number and percentage of tubes plugged to date (Table 5),
: g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6- as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below), and
: g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6-as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below), and
: h. The effective tube plugging percentage for all plugging in each SG (Table 5).
: h. The effective tube plugging percentage for all plugging in each SG (Table 5).
ENO performed an inspection of its two Combustion Engineering (CE) SGs in January-February 2014 during refueling outage 1R23. This inspection was the 1 5 th in-service inspection (ISI) following SG installation in 1990 and the 2 nd of 4 scheduled inspections in the 4th sequential inspection period. The unit initially entered mode 4 following this inspection on March 13, 2014.
ENO performed an inspection of its two Combustion Engineering (CE) SGs in January-February 2014 during refueling outage 1R23. This inspection was the 1 5 th in-service inspection (ISI) following SG installation in 1990 and the 2 nd of 4 scheduled inspections in the 4th sequential inspection period. The unit initially entered mode 4 following this inspection on March 13, 2014.
Line 139: Line 171:
There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future.
There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future.
There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes are affected by this part.
There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes are affected by this part.
Tube Row 3 Column 112 in SG E-50B was preventatively plugged due to being restrictive and difficult to acquire eddy current data. Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1 R21, 1R22, and 1R23 inspections.
Tube Row 3 Column 112 in SG E-50B was preventatively plugged due to being restrictive and difficult to acquire eddy current data. Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1 R21, 1 R22, and 1 R23 inspections.
4 of 156
4 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Tables 4B & 4C provide listings of service induced indications with their location, orientation (if linear), and measured sizes. These two tables list all the wear indications for SG E-50A and SG E-50B identified in eddy current testing including those removed from service by tube plugging.
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Tables 4B & 4C provide listings of service induced indications with their location, orientation (if linear), and measured sizes. These two tables list all the wear indications for SG E-50A and SG E-50B identified in eddy current testing including those removed from service by tube plugging.
Tube Plugging Summary Table 5 provides a summary of the tubes plugged during 1R23 for each active degradation mechanism in each steam generator. This table also includes the total number and percentage of tubes plugged to date along with the effective percentage for all plugging in each SG. No repairs other than plugging (e.g.
Tube Plugging Summary Table 5 provides a summary of the tubes plugged during 1 R23 for each active degradation mechanism in each steam generator. This table also includes the total number and percentage of tubes plugged to date along with the effective percentage for all plugging in each SG. No repairs other than plugging (e.g.
sleeving) have been performed in the Palisades SGs so the effective plugging is equal to the total plugging. Table 6 provides a list of the individual tubes plugged during 1R23.
sleeving) have been performed in the Palisades SGs so the effective plugging is equal to the total plugging. Table 6 provides a list of the individual tubes plugged during 1 R23.
Tube Pulls and In-Situ Pressure Testing No tubes were pulled in either SG. No tubes required in-situ pressure testing per eddy current inspection results in the 2014 refueling outage.
Tube Pulls and In-Situ Pressure Testing No tubes were pulled in either SG. No tubes required in-situ pressure testing per eddy current inspection results in the 2014 refueling outage.
5 of 156
5 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table A Refueling Outage (RFO) Information since Steam Generator Replacement First   Second       Third     Fourth Outage       Cycle   Cumulative Inspection Inspection Inspection Inspection Outage     Year       EFPD       EFPY     Period     Period     Period     Period (EFPMs)   (EFPMs)   (EFPMs)   (EFPMs) 1 R9     1992       298.5     0.82       9.84 1R10       1993       356.8       1.79     11.72 1R11       1995       430.5     2.97       25.87 1R12       1996       407.4     4.09       39.25 1R13       1998       419.6     5.24       53.04 1R14       1999       449.3       6.47                 7.80 1R15     2001       401.3       7.57                 20.98 1R16       2003       444.3     8.78                 35.58 1R17       2004       493.1     10.13                 51.78 1R18       2006       487.9       11.47                             7.81 1R19     2007       459.3       12.73                           22.90 1R20     2009       499.8       14.09                           39.32 1R21     2010         507.7     15.48                           56.00 1R22       2012       504.0     16.84                                       12.54 1R23       2014       513.3     18.25                                       29.14 EFPD = effective full power days EFPM = effective full power months EFPY = effective full power years 6 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table A Refueling Outage (RFO) Information since Steam Generator Replacement First Second Third Fourth Outage Cycle Cumulative Inspection Inspection Inspection Inspection Outage Year EFPD EFPY Period Period Period Period (EFPMs)
(EFPMs)
(EFPMs)
(EFPMs) 1 R9 1992 298.5 0.82 9.84 1R10 1993 356.8 1.79 11.72 1R11 1995 430.5 2.97 25.87 1R12 1996 407.4 4.09 39.25 1R13 1998 419.6 5.24 53.04 1R14 1999 449.3 6.47 7.80 1R15 2001 401.3 7.57 20.98 1R16 2003 444.3 8.78 35.58 1R17 2004 493.1 10.13 51.78 1R18 2006 487.9 11.47 7.81 1R19 2007 459.3 12.73 22.90 1R20 2009 499.8 14.09 39.32 1R21 2010 507.7 15.48 56.00 1R22 2012 504.0 16.84 12.54 1R23 2014 513.3 18.25 29.14 EFPD = effective full power days EFPM = effective full power months EFPY = effective full power years 6 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 1 Scope and Extent of Tubes Inspected Scope                                         Probe Type   SG E-50A     SG E-50B Full LengthO                                     Bobbin         100%         100%
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 1 Scope and Extent of Tubes Inspected Scope Probe Type SG E-50A SG E-50B Full LengthO Bobbin 100%
Row 1 through 3 U-bends                         MRPC           100%         100%
100%
Hot Leg Tubesheets TTS+3"/-1 3.5"               MRPC           100%         100%
Row 1 through 3 U-bends MRPC 100%
Cold Leg Outer Three Periphery Tubes TTS+3"/-2" for detection of               MRPC         12.0%         12.1%
100%
possible loose parts or wear signals Freespan Dings > 5.0 Volts between               MRPC           100%         100%
Hot Leg Tubesheets TTS+3"/-1 3.5" MRPC 100%
TSH and TSC in both SGs Vertical Strap, Diagonal Bar Dents &             MRPC           100%         100%
100%
Eggcrate Dents > 2.0 Volts Historical Wear at Eggcrates                     MRPC           100%         100%
Cold Leg Outer Three Periphery Tubes TTS+3"/-2" for detection of MRPC 12.0%
Historical Wear at Diagonal Bars                 MRPC           25%           25%
12.1%
and Vertical Straps SupplementalO                                   MRPC           100%         100%
possible loose parts or wear signals Freespan Dings > 5.0 Volts between MRPC 100%
Plug Visual                                       N/A         100%         100%
100%
D Except the bend portion of rows 1 through 3 0 All DDI, DSI, NQI, PLP (Bound MRPC           PLPs), PVN and new wear indications.
TSH and TSC in both SGs Vertical Strap, Diagonal Bar Dents &
Table 2 Active Damage Mechanisms SG                           Location                     Damage Mechanism E-50A&B             Diagonal bar (DB) support wear                     Wear E-50A&B             Vertical strap (VS) support wear                   Wear E-50A&B               Eggcrate (EC) support wear                       Wear E-50A&B                 Foreign object (FO) wear                       Wear Axial outer diameter stress corrosion E-50A&B           cracking (ODSCC) at hot leg EC                   Axial ODSCC intersections E-50A&B       Axial ODSCC at hot leg top-of-tubesheet             Axial ODSCC (TTS) locations E-5OA&B       Circumferential ODSCC at hot leg top-of-       Circumferential ODSCC tubesheet (TTS) locations Nondestructive Examination Techniques Beginning on the next page, Table 3 lists the nondestructive examination techniques utilized for each degradation mechanism.
MRPC 100%
100%
Eggcrate Dents > 2.0 Volts Historical Wear at Eggcrates MRPC 100%
100%
Historical Wear at Diagonal Bars MRPC 25%
25%
and Vertical Straps SupplementalO MRPC 100%
100%
Plug Visual N/A 100%
100%
D Except the bend portion of rows 1 through 3 0 All DDI, DSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications.
Table 2 Active Damage Mechanisms SG Location Damage Mechanism E-50A&B Diagonal bar (DB) support wear Wear E-50A&B Vertical strap (VS) support wear Wear E-50A&B Eggcrate (EC) support wear Wear E-50A&B Foreign object (FO) wear Wear Axial outer diameter stress corrosion E-50A&B cracking (ODSCC) at hot leg EC Axial ODSCC intersections E-50A&B Axial ODSCC at hot leg top-of-tubesheet Axial ODSCC (TTS) locations E-5OA&B Circumferential ODSCC at hot leg top-of-Circumferential ODSCC tubesheet (TTS) locations Nondestructive Examination Techniques Beginning on the next page, Table 3 lists the nondestructive examination techniques utilized for each degradation mechanism.
7 of 156
7 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy   Current Technique Palisades 1R23 Degradation P     T                   Demonstrated         Extended Mechanism   PbTe_     _____        [Applicability     Applicability Detection Sizing BOBBIN Tube to Tube               13091.1     Freespan tube-Wear      Bobbin                   to-tube wear Rev. 0at10kz_____                 None        Yes    CMOA at 190 kHz Freespan (excluding u-128413     bend), eggcrate, Axial ODSCC   Bobbin       Rev. 3     sludge pile, &         None       Yes       No broached TSPs with or without dents <2Vpp 24013.1         Freespan Axial ODSCC   Bobbin       Rev. 2     including dings         None       Yes       No R25v Foreign object For r     Bobbin     27091.2             wearnot (part         Extended  for 1-600 tubing   Yes     CMOA Frei                   Rev. 1     present); 1-690 tubing 96004.1       AVBs, TSPs, Support Wear   Bobbin     Rev. 13       vertical and         None       Yes     CMOA diagonal straps 8 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation P
T Demonstrated Extended Mechanism PbTe_
[Applicability Applicability Detection Sizing BOBBIN Tube to Tube 13091.1 Freespan tube-Bobbin to-tube wear None Yes CMOA Wear Rev. 0at10kz_____
at 190 kHz Freespan (excluding u-128413 bend), eggcrate, Axial ODSCC Bobbin Rev. 3 sludge pile, &
None Yes No broached TSPs with or without dents <2Vpp 24013.1 Freespan Axial ODSCC Bobbin Rev. 2 including dings None Yes No R 25v Foreign object wear Extended for Fo r
Bobbin 27091.2 (part not 1-600 tubing Yes CMOA Frei r Rev. 1 present); 1-690 tubing 96004.1 AVBs, TSPs, Support Wear Bobbin Rev. 13 vertical and None Yes CMOA diagonal straps 8 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Degradation Probe Type EPRIEdvCurrntDemonstate ETSS Demonstrated Plsde    1xt23e Extended   Detection   Sizing Mechanism                           Applicability   Applicability 96005.2     Freespan in the Pitting   Bobbin       Rev. 9     presence of     Sludge Pile     Yes       CMOA copper Axial ODSCC 128424 Rev. 3     TSP (with or                                 BED:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 EdvCurrntDemonstate Plsde 1xt23e Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability 96005.2 Freespan in the Pitting Bobbin Rev. 9 presence of Sludge Pile Yes CMOA copper Axial ODSCC 128424 Rev. 3 TSP (with or BED:
without dents whotdnsNone                      Yes      CMOA CO Axial ODSCC +PointTM   (ect; 128431     <=2vpp) and Rev. 2     sludge pile                             BEL: CMOA (sizing) 128425       Freespan Rev. 3     (excluding u-                               BED:
without dents CMOA Axial ODSCC  
(detect) bend), eggcrate,                             CMOA Axial ODSCC +PointTM                 & broached         None         Yes 128432     TSPs with or                             BEL: CMOA Rev.2     without dents (sizing)       <2Vpp Axial ODSCC +Point TM   10411.1     Low Row U-       Higher Row     Yes       CMOA Rev. 0         bends           U-bends 9 of 156
+PointTM (ect; whotdnsNone Yes CO 128431  
<=2vpp) and Rev. 2 sludge pile BEL: CMOA (sizing) 128425 Freespan Rev. 3 (excluding u-BED:
(detect) bend), eggcrate, CMOA Axial ODSCC  
+PointTM  
& broached None Yes 128432 TSPs with or BEL: CMOA Rev.2 without dents (sizing)  
<2Vpp Axial ODSCC  
+Point TM 10411.1 Low Row U-Higher Row Yes CMOA Rev. 0 bends U-bends 9 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1 R23 Degradation Probe Type EPRI ETSS   Demonstrated       Extended   Detection     Sizing Mechanism                           Applicability   Applicability Support                                   PDA:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1 R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Support PDA:
structures,                             Information Axial ODSCC +Point TM   21409.1       freespan,       U-bends       Yes Rev. 7     sludge pile, &
structures, Information Axial ODSCC  
tubesheet                                 Length:
+Point TM 21409.1
crevice                               Information Depth:
: freespan, U-bends Yes Rev. 7 sludge pile, &
22401.1                       Freespan               Information Axial ODSCC +PointTM     Rev. 4     Dented TSPs         dings &       Yes dented AVBs                 Length:
tubesheet Length:
crevice Information Depth:
22401.1 Freespan Information Axial ODSCC  
+PointTM Rev. 4 Dented TSPs dings &
Yes dented AVBs Length:
CMOA PDA:
CMOA PDA:
Expansion     Tubesheet &               Information Axial PWSCC +PointTM     20511.1 Rev. 8         pansion Transitions     non-dented spot           Yes          egh supports                 Length:
Expansion Tubesheet &
Information Axial PWSCC  
+PointTM 20511.1 pansion non-dented Yes Rev. 8 Transitions spot egh supports Length:
CMOA Depth:
CMOA Depth:
96703.1                     Tubesheet &                 CMOA M
96703.1 Tubesheet &
Axial PWSCC +Point      960.1           Dents       non-dented     Yes Rev. 17                       supports                 Length:
CMOA Axial PWSCC  
CMOA Axial PWSCC +Point TM   96511.2     Low Row U-       Higher Row     Yes         CMOA Rev. 16         bends         U-bends Axial PWSCC +Point TM   99997.2       Low Row U-       Higher Row     Yes         CMOA Rev. 10         bends         U-bends 10 of 156
+PointM 960.1 Dents non-dented Yes Rev. 17 supports Length:
CMOA Axial PWSCC  
+Point TM 96511.2 Low Row U-Higher Row Yes CMOA Rev. 16 bends U-bends Axial PWSCC  
+Point TM 99997.2 Low Row U-Higher Row Yes CMOA Rev. 10 bends U-bends 10 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated           Extended     Detection     Sizing Mechanism                             Applicability   Applicability Circ ODSCC Depth:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Circ ODSCC Depth:
Information Circ ODSCC   +Point TM   21410.1       Expansion         None         Yes         PDA:
Information Circ ODSCC  
Rev. 6     Transitions                                 CMOA Length:
+Point TM 21410.1 Expansion None Yes PDA:
CMOA Circ ODSCC   +Point TM   22842.1         Dented         Freespan     Yes         CMOA Rev. 4       Supports         dings EPI     Expansion         NnSing                   PDA:
Rev. 6 Transitions CMOA Length:
CMOA EPRI Circ ODSCC   +Point TM TR-1 07197-   Transitions         None       Sizing       Depth:
CMOA Circ ODSCC  
P1                                                   CMOA Circ PWSCC Circ PWSCC   +PointTM     111524       Expansion         None       Yes           No Rev. 0     Transitions Circ PWSCC   +PointTM   20510.1       Expansion       U-bends       Yes         CMOA Rev. 7     Transitions Low Row U-       Higher Row                   For S96511.2 Circ PWSCC   +PointTM     Rev. 16     Lowbends R   U     H U-bends er o     Yes     information ol only Circ PWSCC   +PointTM     96701.1       Expansion       Dents and     Yes         CMOA Rev. 12     Transitions     tubesheet 11 of 156
+Point TM 22842.1 Dented Freespan Yes CMOA Rev. 4 Supports dings EPRI PDA:
EPI Expansion NnSing CMOA Circ ODSCC  
+Point TM TR-1 07197-Transitions None Sizing Depth:
P1 CMOA Circ PWSCC Circ PWSCC  
+PointTM 111524 Expansion None Yes No Rev. 0 Transitions Circ PWSCC  
+PointTM 20510.1 Expansion U-bends Yes CMOA Rev. 7 Transitions S96511.2 Low Row U-Higher Row For Circ PWSCC  
+PointTM 16 Low R U
H er o
Yes information Rev. 16 bends U-bends olonly Circ PWSCC  
+PointTM 96701.1 Expansion Dents and Yes CMOA Rev. 12 Transitions tubesheet 11 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated             Extended   Detection     Sizing Mechanism                             Applicability   Applicability Detection     Sizing S99997.2     Low Row U-       Higher Row                   For Circ PWSCC   +PointTM   Rev. 10           Row U bends         Hier U-bendso    Yes      information ol only Wear Pitting tTM   21998.1       Volumetric in Pitting +Poin         Rev. 4       freespan       Sludge Pile   Yes         CMOA Specialty Probes Both:
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Detection Sizing S99997.2 Low Row U-Higher Row For Circ PWSCC  
CMOA 20407.1         Support Axial ODSCC   Ghent**     Rev. 7     structures &         None       Yes     Avg. Depth/
+PointTM Rev. 10 Row U Hier o Yes information Rev. 10 bends U-bends ol only Wear Pitting tTM 21998.1 Volumetric in Pitting  
freespan                                   Length applies to technique 12 of 156
+Poin Rev. 4 freespan Sludge Pile Yes CMOA Specialty Probes Both:
CMOA 20407.1 Support Axial ODSCC Ghent**
Rev. 7 structures &
None Yes Avg. Depth/
freespan Length applies to technique 12 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 ddy Current Technique Palisades 1R23 Degradation       Probe Type   EPRI ETSS Demonstrated             Extended Probe                         Applicability     Applicability   Detection       Sizing Mechanism CMOA Axial PWSCC         Ghent**       20508.1         Expansion           None           Yes           Length Rev. 6         Transitions                                     applies to technique Axial PWSCC         Ghent**       20509.1       Dented support         None           Yes           Not Rev. 5         structures                                       qualified CMOA Top of Circ ODSCC         Ghent**       20406.1       tubesheet &           None           Yes           Depth/
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 ddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Mechanism Probe Applicability Applicability Detection Sizing CMOA Axial PWSCC Ghent**
Rev. 7         expansion                                         Length/
20508.1 Expansion None Yes Length Rev. 6 Transitions applies to technique Axial PWSCC Ghent**
transitions                                   PDA apply to technique Circ PWSCC         Ghent**       20507.1         Expansion           None           Yes           CMOA Rev. 6         Transitions
20509.1 Dented support None Yes Not Rev. 5 structures qualified CMOA Top of Circ ODSCC Ghent**
* There are multiple ETSSs available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used. If foreign object wear (with no part present) is reported, an appropriate +Point TM or pancake coil technique will be selected for performing CMOA. The associated NDE uncertainties and CMOA limits will be documented in the CMOA report.
20406.1 tubesheet &
**The Ghent probe will only be used if needed for clarification of the eddy current response or for additional sizing information associated with unusual or unexpected indications.
None Yes Depth/
Rev. 7 expansion Length/
transitions PDA apply to technique Circ PWSCC Ghent**
20507.1 Expansion None Yes CMOA Rev. 6 Transitions
* There are multiple ETSSs available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used. If foreign object wear (with no part present) is reported, an appropriate +Point TM or pancake coil technique will be selected for performing CMOA. The associated NDE uncertainties and CMOA limits will be documented in the CMOA report.
** The Ghent probe will only be used if needed for clarification of the eddy current response or for additional sizing information associated with unusual or unexpected indications.
13 of 156
13 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Axial ODSCC Indications
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Axial ODSCC Indications
                                      +Point 300     NDE Maximum                                               Structural kHz         NDEEMaximumSStructura SG     Row   Col. Location       +on             Depth (%TW)       NDE Axial         Structural       Depth (%TW)
+Point 300 NDE Maximum Structural kHz NDEEMaximumSStructura SG Row Col.
Amplitude           (Note 1)       Length (in.)     Length (in.)         (Note 1)
Location  
(Vpp)                   1)                                             (Note_1)
+on Depth (%TW)
SGA     23     118   01H -0.81         0.30             42.81           0.27                 -                  -
NDE Axial Structural Depth (%TW)
SGA     33     52   TSH +0.35         0.225*             42.21           0.24               0.19               35.3 SGA     33     52   TSH +0.63           0.73*             61.69           0.28               0.19               53.9 SGB     23     46   TSH +0.43         0.615*             58.85           0.20               0.14               52.0 SGB     23     110   01H -0.23         0.27             40.61           0.96                 -                  -
Amplitude (Note 1)
SGB     29     106   01H -0.28         0.35*             46.03           1.51               0.6               41.0 SGB     76     95   TSH +1.40           0.41             52.14           0.39 SGB     82     115   01H -0.97         0.38             47.75           0.14 Note 1) The NDE maximum depth values were calculated using the Appendix I regression techniques (%TW as function of NDE voltage) and then reduced by 11 %TW as identified in the Entergy Appendix I deviation. Both the NDE Maximum Depth and Structural Depth values, shown in this table, reflect the 11 %TW reduction.
Length (in.)
Length (in.)
(Note 1)
(Vpp)
: 1)
(Note_1)
SGA 23 118 01H -0.81 0.30 42.81 0.27 SGA 33 52 TSH +0.35 0.225*
42.21 0.24 0.19 35.3 SGA 33 52 TSH +0.63 0.73*
61.69 0.28 0.19 53.9 SGB 23 46 TSH +0.43 0.615*
58.85 0.20 0.14 52.0 SGB 23 110 01H -0.23 0.27 40.61 0.96 SGB 29 106 01H -0.28 0.35*
46.03 1.51 0.6 41.0 SGB 76 95 TSH +1.40 0.41 52.14 0.39 SGB 82 115 01H -0.97 0.38 47.75 0.14 Note 1) The NDE maximum depth values were calculated using the Appendix I regression techniques (%TW as function of NDE voltage) and then reduced by 11 %TW as identified in the Entergy Appendix I deviation. Both the NDE Maximum Depth and Structural Depth values, shown in this table, reflect the 11 %TW reduction.
* The average voltage (average of lead-in and lead-out) was used for the indications that received line by line sizing; hence, these voltages are not be found in FDMS and can result in three digits.
* The average voltage (average of lead-in and lead-out) was used for the indications that received line by line sizing; hence, these voltages are not be found in FDMS and can result in three digits.
14 of 156
14 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location   and Measured   Sizes of Service Induced Indications Circumferential ODSCC Indications NDE Percent
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Circumferential ODSCC Indications NDE Percent
                                                        +Point 300 kHz         Degraded Area     Circumferential Amplitude (Vpp)             (PDA)           Length (deg.)
+Point 300 kHz Degraded Area Circumferential Amplitude (Vpp)
(PDA)
Length (deg.)
(Note 1)
(Note 1)
SGA       24       49           TSH +0.24                 0.43                   4.90                 54 SGA       40       51           TSH +0.12                 0.39                   6.38                 101 SGA       40       51             TSH -0.08                 0.30                   4.90                 50 SGA       56       59             TSH -0.15                 0.30                   9.33                 77 SGA       76       79           TSH +0.13                 0.29                   9.38                 70 SGA       105     104           TSH -0.03                 0.25                   2.92                 54 SGB       28       51           TSH +0.07                 0.40                   11.7                 77 SGB       74       75           TSH -0.05                 0.35                   2.2                   50 Note 1) All Circumferential indications were sized using the EPRI Draw Program which measured depths circumferentially from which a Percent Degraded Area (PDA) was calculated.
SGA 24 49 TSH +0.24 0.43 4.90 54 SGA 40 51 TSH +0.12 0.39 6.38 101 SGA 40 51 TSH -0.08 0.30 4.90 50 SGA 56 59 TSH -0.15 0.30 9.33 77 SGA 76 79 TSH +0.13 0.29 9.38 70 SGA 105 104 TSH -0.03 0.25 2.92 54 SGB 28 51 TSH +0.07 0.40 11.7 77 SGB 74 75 TSH -0.05 0.35 2.2 50 Note 1) All Circumferential indications were sized using the EPRI Draw Program which measured depths circumferentially from which a Percent Degraded Area (PDA) was calculated.
15 of 156
15 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Volumetric Indications with Loose Part Present Sizing                       Circumferential NDE Axial SG Row   Col. Location       ETSS         Depth (%TW)   Length (deg.)   Length (in.)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Volumetric Indications with Loose Part Present Sizing Circumferential NDE Axial SG Row Col.
Location ETSS Depth (%TW)
Length (deg.)
Length (in.)
(Note 1)
(Note 1)
SGA   133   74   TSH +0.01     27901.1             37             58           0.33 SGA   134   75   TSH +0.00     27901.1             51             70           0.30 SGB 1 108   35   TSC+0.00       10908.4             11             54           0.23 16 of 156
SGA 133 74 TSH +0.01 27901.1 37 58 0.33 SGA 134 75 TSH +0.00 27901.1 51 70 0.30 SGB 1 108 35 TSC+0.00 10908.4 11 54 0.23 16 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1     A       1         2         12       04C       -1.04   <TS 2     A       1         2         9       02H       0.87   <TS 3     A       1       128         11       02C       0.92   <TS 4     A       1       136         13       02H       -0.95   <TS 5     A       1       140         6       DBH       -0.99   <TS 6     A       1       150         18       02C       0.87   <TS 7     A       1       150         12       01C       -0.15   <TS 8     A       1       162         10       01C       0.88   <TS 9     A       2         7         9       02H       0.76   <TS 10     A       2         9         11       02C       -0.98   <TS 11     A       2       31         11       03H       0.85   <TS 12     A       2       127         19       05C       0.44   <TS 13     A       2       127         10       DBH       1.19   <TS 14     A       2       159         11       03C       -0.13   <TS 15     A       3       14         10       04C       0.86   <TS 16     A       3       128         15       02C       0.85   <TS 17     A       3       144         10       04H       0.81   <TS 18     A       3       164         10       03H       -0.89   <TS 19     A       3       164         12       02C       0.83   <TS 20     A       4       55         14       DBC       0.38   <TS 21     A       4       115         13       04C       0.87   <TS 22     A       4       137         13       02C       0.87   <TS 23     A       4       157         13       02C       0.89   <TS 24     A       4       157         10       02C       -0.17   <TS 25     A       5       38         11       03H       0.92   <TS 26     A       5       130         13       02C       0.91   <TS 27     A       5       132         9       03C       -0.91   <TS 28     A       6       131         6       02H       -0.06   <TS 29     A       6       147         12       04H       -0.91   <TS 30     A       8       161         11       02C       -0.91   <TS 31     A       9         2         17       02C       0.19   <TS 32     A       9         4           9       02C       -0.17   <TS 33     A       9       32         14       DBC       1.42   <TS 34     A       9       36         13       02H       -0.86   <TS 35     A       10         7         12       02C       0.83   <TS 36     A       10       21         12       04H       0.9   <TS 37     A       10       29         9       02H       0.87   <TS 38     A       10       39         12       05H       -0.06   <TS 39     A       10       165         13       DBH       1.59   <TS 17 of 156
Percent No SG Row Column in Depth Location Elevation TS 1
A 1
2 12 04C  
-1.04  
<TS 2
A 1
2 9
02H 0.87  
<TS 3
A 1
128 11 02C 0.92  
<TS 4
A 1
136 13 02H  
-0.95  
<TS 5
A 1
140 6
DBH  
-0.99  
<TS 6
A 1
150 18 02C 0.87  
<TS 7
A 1
150 12 01C  
-0.15  
<TS 8
A 1
162 10 01C 0.88  
<TS 9
A 2
7 9
02H 0.76  
<TS 10 A
2 9
11 02C  
-0.98  
<TS 11 A
2 31 11 03H 0.85  
<TS 12 A
2 127 19 05C 0.44  
<TS 13 A
2 127 10 DBH 1.19  
<TS 14 A
2 159 11 03C  
-0.13  
<TS 15 A
3 14 10 04C 0.86  
<TS 16 A
3 128 15 02C 0.85  
<TS 17 A
3 144 10 04H 0.81  
<TS 18 A
3 164 10 03H  
-0.89  
<TS 19 A
3 164 12 02C 0.83  
<TS 20 A
4 55 14 DBC 0.38  
<TS 21 A
4 115 13 04C 0.87  
<TS 22 A
4 137 13 02C 0.87  
<TS 23 A
4 157 13 02C 0.89  
<TS 24 A
4 157 10 02C  
-0.17  
<TS 25 A
5 38 11 03H 0.92  
<TS 26 A
5 130 13 02C 0.91  
<TS 27 A
5 132 9
03C  
-0.91  
<TS 28 A
6 131 6
02H  
-0.06  
<TS 29 A
6 147 12 04H  
-0.91  
<TS 30 A
8 161 11 02C  
-0.91  
<TS 31 A
9 2
17 02C 0.19  
<TS 32 A
9 4
9 02C  
-0.17  
<TS 33 A
9 32 14 DBC 1.42  
<TS 34 A
9 36 13 02H  
-0.86  
<TS 35 A
10 7
12 02C 0.83  
<TS 36 A
10 21 12 04H 0.9  
<TS 37 A
10 29 9
02H 0.87  
<TS 38 A
10 39 12 05H  
-0.06  
<TS 39 A
10 165 13 DBH 1.59  
<TS 17 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 40     A       11         4           8     02C       -0.19   <TS 41     A       11       146         13       03C       0.92   <TS 42     A       12         3         15       02C       0.82   <TS 43     A       12         7           8     02C       -0.9   <TS 44     A       12       123         15       DBH       0.96   <TS 45     A       12       133         10       03C       0.17   <TS 46     A       12       137         10       02H       -0.8   <TS 47     A       12       159         10       05H       0.94   <TS 48     A       13         2         20       02H       0.89   <TS 49     A       13         2         13       02H       -0.86   <TS 50     A       13         4         16       02C       0.81   <TS 51     A       13         8           7     03C       0.79   <TS 52     A       13         8           8     02C       -0.25   <TS 53     A       13       32         24       05C       -0.26   <TS 54     A       13       34         17       03C       -0.98   <TS 55     A       13       36         13       05C       0.78   <TS 56     A       13       146         15       DBC       -1.17   <TS 57     A       13       158         10     03H       0.88   <TS 58     A       14         3         26       02C       0.96   <TS 59     A       14       59         19       05H       0.83   <TS 60     A       14       59         10       02H       0.92   <TS 61     A       15         2           9     03C       -0.15   <TS 62     A       15       14         10       05C       0.84   <TS 63     A       15       28         11       05H         1   <TS 64     A       15       36           8     02C       -0.87   <TS 65     A       15       62         11       04C       -0.13   <TS 66     A       15       154         13     DBC         1.5   <TS 67     A       15       156           8     03H       -0.13   <TS 68     A       16         9           9     03C       0.84   <TS 69     A       16       11         10       02H       -0.77   <TS 70     A       17         2         12       04H       0.85   <TS 71     A       17       58         14     02C       0.83   <TS 72     A       17       60         11     02C       -0.81   <TS 73     A       18         3         12     02H       0.83   <TS 74     A       18         3         11       02H       -0.86   <TS 75     A       18       23         10       VS4       -0.87   <TS 76     A       18       25         13     VS4       -0.92   <TS 77     A       18       49         11     VS4       -1.01   <TS 78     A       18       51         16     VS4       -0.94   <TS 18 of 156
Percent No SG Row Column in Depth Location Elevation TS 40 A
11 4
8 02C  
-0.19  
<TS 41 A
11 146 13 03C 0.92  
<TS 42 A
12 3
15 02C 0.82  
<TS 43 A
12 7
8 02C  
-0.9  
<TS 44 A
12 123 15 DBH 0.96  
<TS 45 A
12 133 10 03C 0.17  
<TS 46 A
12 137 10 02H  
-0.8  
<TS 47 A
12 159 10 05H 0.94  
<TS 48 A
13 2
20 02H 0.89  
<TS 49 A
13 2
13 02H  
-0.86  
<TS 50 A
13 4
16 02C 0.81  
<TS 51 A
13 8
7 03C 0.79  
<TS 52 A
13 8
8 02C  
-0.25  
<TS 53 A
13 32 24 05C  
-0.26  
<TS 54 A
13 34 17 03C  
-0.98  
<TS 55 A
13 36 13 05C 0.78  
<TS 56 A
13 146 15 DBC  
-1.17  
<TS 57 A
13 158 10 03H 0.88  
<TS 58 A
14 3
26 02C 0.96  
<TS 59 A
14 59 19 05H 0.83  
<TS 60 A
14 59 10 02H 0.92  
<TS 61 A
15 2
9 03C  
-0.15  
<TS 62 A
15 14 10 05C 0.84  
<TS 63 A
15 28 11 05H 1  
<TS 64 A
15 36 8
02C  
-0.87  
<TS 65 A
15 62 11 04C  
-0.13  
<TS 66 A
15 154 13 DBC 1.5  
<TS 67 A
15 156 8
03H  
-0.13  
<TS 68 A
16 9
9 03C 0.84  
<TS 69 A
16 11 10 02H  
-0.77  
<TS 70 A
17 2
12 04H 0.85  
<TS 71 A
17 58 14 02C 0.83  
<TS 72 A
17 60 11 02C  
-0.81  
<TS 73 A
18 3
12 02H 0.83  
<TS 74 A
18 3
11 02H  
-0.86  
<TS 75 A
18 23 10 VS4  
-0.87  
<TS 76 A
18 25 13 VS4  
-0.92  
<TS 77 A
18 49 11 VS4  
-1.01  
<TS 78 A
18 51 16 VS4  
-0.94  
<TS 18 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 79     A       18       53       14       DBH       -0.72   <TS 80     A       18       59         9       02H         0.9   <TS 81     A       19       56       17       DBC       0.98   <TS 82     A       19       64       20       DBC       -1.58   <TS 83     A       19       64       17       DBH       -1.58   <TS 84     A       19       64         7       DBH       1.72   <TS 85     A       19       112       13       04C       0.83   <TS 86     A       19       144       11       04C         0.9   <TS 87     A       20         3       10       02C       -0.85   <TS 88     A       20       57       10       02H       0.89   <TS 89     A       20       59         7       03C       -0.98   <TS 90     A       20       103         9       04H       -0.11   <TS 91     A       20       163       11       02C       0.13   <TS 92     A       20       163       10       02C       0.88   <TS 93     A       21       2         11       04H       0.83   <TS 94     A       21       60       11       04C       -0.9   <TS 95     A       21       64       13       DBH       -1.68   <TS 96     A       21       114         9       02H       0.11   <TS 97     A       22       3         14       02C       -0.92   <TS 98     A       22       9         11       02C       -0.9   <TS 99     A       22       53       14       DBH       0.42   <TS 100     A       22       159       12       02H       0.91   <TS 101     A       22       161         9       02H         0.9   <TS 102     A       22       163       13       02H       -0.8   <TS 103     A       23       4         12       02C       -0.87   <TS 104     A       23       40         12       VS4       0.91   <TS 105     A       23       40         21       VS4       -1.12   <TS 106     A       23       58         6       04C       0.94   <TS 107     A       23       60         7       02H       -0.87   <TS 108     A       23       62         13       02C       0.84   <TS 109     A       23       104         6       03C       0.18   <TS 110     A       23       104         9       03C       -0.9   <TS 111     A       23       122       13       VS4       0.83   <TS 112     A       24       33       11       01H       0.85   <TS 113     A       24       41         12       VS4       -0.94   <TS 114     A       24       61         15       03C       -0.88   <TS 115     A       24       161       15       02C       0.84   <TS 116     A       24       161       12       02C       -0.81   <TS 117     A       24       163       18       02C         0.8   <TS 19 of 156
Percent No SG Row Column in Depth Location Elevation TS 79 A
18 53 14 DBH  
-0.72  
<TS 80 A
18 59 9
02H 0.9  
<TS 81 A
19 56 17 DBC 0.98  
<TS 82 A
19 64 20 DBC  
-1.58  
<TS 83 A
19 64 17 DBH  
-1.58  
<TS 84 A
19 64 7
DBH 1.72  
<TS 85 A
19 112 13 04C 0.83  
<TS 86 A
19 144 11 04C 0.9  
<TS 87 A
20 3
10 02C  
-0.85  
<TS 88 A
20 57 10 02H 0.89  
<TS 89 A
20 59 7
03C  
-0.98  
<TS 90 A
20 103 9
04H  
-0.11  
<TS 91 A
20 163 11 02C 0.13  
<TS 92 A
20 163 10 02C 0.88  
<TS 93 A
21 2
11 04H 0.83  
<TS 94 A
21 60 11 04C  
-0.9  
<TS 95 A
21 64 13 DBH  
-1.68  
<TS 96 A
21 114 9
02H 0.11  
<TS 97 A
22 3
14 02C  
-0.92  
<TS 98 A
22 9
11 02C  
-0.9  
<TS 99 A
22 53 14 DBH 0.42  
<TS 100 A
22 159 12 02H 0.91  
<TS 101 A
22 161 9
02H 0.9  
<TS 102 A
22 163 13 02H  
-0.8  
<TS 103 A
23 4
12 02C  
-0.87  
<TS 104 A
23 40 12 VS4 0.91  
<TS 105 A
23 40 21 VS4  
-1.12  
<TS 106 A
23 58 6
04C 0.94  
<TS 107 A
23 60 7
02H  
-0.87  
<TS 108 A
23 62 13 02C 0.84  
<TS 109 A
23 104 6
03C 0.18  
<TS 110 A
23 104 9
03C  
-0.9  
<TS 111 A
23 122 13 VS4 0.83  
<TS 112 A
24 33 11 01H 0.85  
<TS 113 A
24 41 12 VS4  
-0.94  
<TS 114 A
24 61 15 03C  
-0.88  
<TS 115 A
24 161 15 02C 0.84  
<TS 116 A
24 161 12 02C  
-0.81  
<TS 117 A
24 163 18 02C 0.8  
<TS 19 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 118     A       25       56         11       03C       -0.94   <TS 119     A       25       60         13       03C       0.93   <TS 120     A       25       110         16       04C       0.75   <TS 121     A       26         3         17       02C       -0.85   <TS 122     A       26         5         13       02H       -0.15   <TS 123     A       26         5         13       02H       -0.8   <TS 124     A       26       51         10       02H       0.93   <TS 125     A       26       121         13       VS4       -0.73   <TS 126     A       26       121         16       VS4       -0.18   <TS 127     A       26       125         13       VS4       -0.05   <TS 128   A       26       161         15       03H       0.74   <TS 129     A       26       163         15       01H       0.95   <TS 130     A       27         6         10       02H       -0.84   <TS 131     A       27         8         14       02C       -0.92   <TS 132     A       27       10         7       05H       -0.13   <TS 133     A       27       10         8       05H       0.92   <TS 134   A       27       58         11       02H       0.93   <TS 135   A       28         3         13       02C       -0.92   <TS 136     A       28         5         14       DBC       1.51   <TS 137     A       28       19         21       VS4       -1.01   <TS 138     A       28       31         22       VS4       -0.93   <TS 139   A       28       35         13       DBH       0.86   <TS 140     A       28       43         10       VS4       -1.12   <TS 141     A       28       63         12       05H       0.99   <TS 142     A       28       63         18       VS4       -1.08   <TS 143     A       28       105         10       03C       0.15   <TS 144     A       28       161         9       01H       -0.91   <TS 145     A       29       64         13       05H       0.95   <TS 146     A       29       122         9       02H       0.91   <TS 147     A       29       162         14       01H       -0.76   <TS 148     A       30       35         9       02H       0.9   <TS 149     A       30       55         8       03H       0.9   <TS 150     A       30       57         8       04H       0.91   <TS 151     A       30       59         11       02C       -0.85   <TS 152     A       30       59         12       04C       0.87   <TS 153     A       31         4         12       02H       -0.84   <TS 154     A       31       42         8       02C       0.86   <TS 155     A       31       44         12       02C       0.92   <TS 156     A       31       60         8       02H       0.82   <TS 20 of 156
Percent No SG Row Column in Depth Location Elevation TS 118 A
25 56 11 03C  
-0.94  
<TS 119 A
25 60 13 03C 0.93  
<TS 120 A
25 110 16 04C 0.75  
<TS 121 A
26 3
17 02C  
-0.85  
<TS 122 A
26 5
13 02H  
-0.15  
<TS 123 A
26 5
13 02H  
-0.8  
<TS 124 A
26 51 10 02H 0.93  
<TS 125 A
26 121 13 VS4  
-0.73  
<TS 126 A
26 121 16 VS4  
-0.18  
<TS 127 A
26 125 13 VS4  
-0.05  
<TS 128 A
26 161 15 03H 0.74  
<TS 129 A
26 163 15 01H 0.95  
<TS 130 A
27 6
10 02H  
-0.84  
<TS 131 A
27 8
14 02C  
-0.92  
<TS 132 A
27 10 7
05H  
-0.13  
<TS 133 A
27 10 8
05H 0.92  
<TS 134 A
27 58 11 02H 0.93  
<TS 135 A
28 3
13 02C  
-0.92  
<TS 136 A
28 5
14 DBC 1.51  
<TS 137 A
28 19 21 VS4  
-1.01  
<TS 138 A
28 31 22 VS4  
-0.93  
<TS 139 A
28 35 13 DBH 0.86  
<TS 140 A
28 43 10 VS4  
-1.12  
<TS 141 A
28 63 12 05H 0.99  
<TS 142 A
28 63 18 VS4  
-1.08  
<TS 143 A
28 105 10 03C 0.15  
<TS 144 A
28 161 9
01H  
-0.91  
<TS 145 A
29 64 13 05H 0.95  
<TS 146 A
29 122 9
02H 0.91  
<TS 147 A
29 162 14 01H  
-0.76  
<TS 148 A
30 35 9
02H 0.9  
<TS 149 A
30 55 8
03H 0.9  
<TS 150 A
30 57 8
04H 0.91  
<TS 151 A
30 59 11 02C  
-0.85  
<TS 152 A
30 59 12 04C 0.87  
<TS 153 A
31 4
12 02H  
-0.84  
<TS 154 A
31 42 8
02C 0.86  
<TS 155 A
31 44 12 02C 0.92  
<TS 156 A
31 60 8
02H 0.82  
<TS 20 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 157   A       31       126         18       VS4       -0.77   <TS 158   A       31       126         11       VS4       0.29   <TS 159   A       31       128         20       VS4       -0.76   <TS 160   A       31       128         20       VS4       0.94   <TS 161   A       32         7         22       02C       -0.9   <TS 162   A       32       37         17       03H       0.92   <TS 163   A       32       37         10       03H       0.06   <TS 164   A       32       59         18       DBH       0.39   <TS 165   A       32       109         10       VS4       -0.24   <TS 166   A       32       145         20       VS4       -0.98   <TS 167   A       32       161         13       03H       -0.19   <TS 168   A       33       22         14       DBH       1.99   <TS 169   A       33       38         14       03H       -0.83   <TS 170   A       33       46         14       02H       0.83   <TS 171   A       33       48         12       02H         0.9   <TS 172   A       33       58         8       04H       0.91   <TS 173   A       33       62         12       04C       -0.78   <TS 174   A       33       116         10       02H       -0.78   <TS 175   A       33       116         9       03H       0.87   <TS 176   A       33       124         13       VS4       0.66   <TS 177   A       33       124         13       03C       0.92   <TS 178   A       34       15         14       VS4       -0.69   <TS 179   A       34       39         7       02H       0.85   <TS 180   A       34       57         11       04C       0.86   <TS 181   A       34       57         10       04H       0.97   <TS 182   A       34       59         10       04H       0.88   <TS 183   A       34       59         10       04H       -0.13   <TS 184   A       34       63         15       04C       0.88   <TS 185   A       34       63         15       DBC         1.3   <TS 186   A       34       109         16       04H       0.97   <TS 187   A       34       117         11       03C       -0.9   <TS 188   A       34       119         13       03H       0.92   <TS 189   A       34       121         12       03C       0.94   <TS 190   A       34       131         10       05C       -0.15   <TS 191   A       35       48         13       03C       -0.91   <TS 192   A       35       48         6       02C       -0.83   <TS 193   A       35       114         15       DBC       1.95   <TS 194   A       36       47         12       DBH       -1.5   <TS 195   A       36       49         16       02C       -0.89   <TS 21 of 156
Percent No SG Row Column in Depth Location Elevation TS 157 A
31 126 18 VS4  
-0.77  
<TS 158 A
31 126 11 VS4 0.29  
<TS 159 A
31 128 20 VS4  
-0.76  
<TS 160 A
31 128 20 VS4 0.94  
<TS 161 A
32 7
22 02C  
-0.9  
<TS 162 A
32 37 17 03H 0.92  
<TS 163 A
32 37 10 03H 0.06  
<TS 164 A
32 59 18 DBH 0.39  
<TS 165 A
32 109 10 VS4  
-0.24  
<TS 166 A
32 145 20 VS4  
-0.98  
<TS 167 A
32 161 13 03H  
-0.19  
<TS 168 A
33 22 14 DBH 1.99  
<TS 169 A
33 38 14 03H  
-0.83  
<TS 170 A
33 46 14 02H 0.83  
<TS 171 A
33 48 12 02H 0.9  
<TS 172 A
33 58 8
04H 0.91  
<TS 173 A
33 62 12 04C  
-0.78  
<TS 174 A
33 116 10 02H  
-0.78  
<TS 175 A
33 116 9
03H 0.87  
<TS 176 A
33 124 13 VS4 0.66  
<TS 177 A
33 124 13 03C 0.92  
<TS 178 A
34 15 14 VS4  
-0.69  
<TS 179 A
34 39 7
02H 0.85  
<TS 180 A
34 57 11 04C 0.86  
<TS 181 A
34 57 10 04H 0.97  
<TS 182 A
34 59 10 04H 0.88  
<TS 183 A
34 59 10 04H  
-0.13  
<TS 184 A
34 63 15 04C 0.88  
<TS 185 A
34 63 15 DBC 1.3  
<TS 186 A
34 109 16 04H 0.97  
<TS 187 A
34 117 11 03C  
-0.9  
<TS 188 A
34 119 13 03H 0.92  
<TS 189 A
34 121 12 03C 0.94  
<TS 190 A
34 131 10 05C  
-0.15  
<TS 191 A
35 48 13 03C  
-0.91  
<TS 192 A
35 48 6
02C  
-0.83  
<TS 193 A
35 114 15 DBC 1.95  
<TS 194 A
36 47 12 DBH  
-1.5  
<TS 195 A
36 49 16 02C  
-0.89  
<TS 21 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 196   A       36       59         10       03H       0.86   <TS 197   A       36       61         15       04H       -0.22   <TS 198   A       36       61         12       DBH       1.69   <TS 199   A       36       105         12       02C       0.85   <TS 200     A       36       109         11       VS4       0.09   <TS 201     A       36       117         11       03C       0.11   <TS 202     A       36       117         16       02H       0.83   <TS 203     A       37         6         12       02C       -0.9   <TS 204     A       37         6         9       02C       0.88   <TS 205     A       37       24         14       05C       0.93   <TS 206     A       37       30         8       05H       -0.88   <TS 207     A       37       30         9       05H       0.93   <TS 208     A       37       34         20       DBC         1.6   <TS 209     A       37       34         12       04H       0.91   <TS 210     A       37       36         12       04H       -0.09   <TS 211     A       37       36         10       04H       -0.81   <TS 212     A       37       38         19       03C         1   <TS 213     A       37       42         12       02H       0.84   <TS 214     A       37       48         13       04H       -0.84   <TS 215     A       37       50         10       04C       0.2   <TS 216     A       37       50         10       04H       -0.9   <TS 217     A       37       50         14       04H       0.92   <TS 218     A       37       52         16       04C       -0.88   <TS 219     A       37       56         12       04C       -0.99   <TS 220     A       37       56         13       05C       -0.13   <TS 221     A       37       56         12       05H       0.94   <TS 222     A       37       56         22       04H       1.03   <TS 223     A       37       60         14       03H       -0.9   <TS 224     A       37       62         18       04H       0.94   <TS 225     A       37       62         16       05H       -0.81   <TS 226     A       37       106         18       03C       -0.79   <TS 227     A       37       116         15       03C       0.87   <TS 228     A       37       128         15       VS4       -0.86   <TS 229     A       37       128         20       VS4       0.82   <TS 230     A       37       134         11       05H       0.88   <TS 231     A       38       11         11       05H       0.87   <TS 232     A       38       13         9       05C       0.89   <TS 233     A       38       17         16       05H       -0.15   <TS 234     A       38       35         18       03H       0.88   <TS 22 of 156
Percent No SG Row Column in Depth Location Elevation TS 196 A
36 59 10 03H 0.86  
<TS 197 A
36 61 15 04H  
-0.22  
<TS 198 A
36 61 12 DBH 1.69  
<TS 199 A
36 105 12 02C 0.85  
<TS 200 A
36 109 11 VS4 0.09  
<TS 201 A
36 117 11 03C 0.11  
<TS 202 A
36 117 16 02H 0.83  
<TS 203 A
37 6
12 02C  
-0.9  
<TS 204 A
37 6
9 02C 0.88  
<TS 205 A
37 24 14 05C 0.93  
<TS 206 A
37 30 8
05H  
-0.88  
<TS 207 A
37 30 9
05H 0.93  
<TS 208 A
37 34 20 DBC 1.6  
<TS 209 A
37 34 12 04H 0.91  
<TS 210 A
37 36 12 04H  
-0.09  
<TS 211 A
37 36 10 04H  
-0.81  
<TS 212 A
37 38 19 03C 1  
<TS 213 A
37 42 12 02H 0.84  
<TS 214 A
37 48 13 04H  
-0.84  
<TS 215 A
37 50 10 04C 0.2  
<TS 216 A
37 50 10 04H  
-0.9  
<TS 217 A
37 50 14 04H 0.92  
<TS 218 A
37 52 16 04C  
-0.88  
<TS 219 A
37 56 12 04C  
-0.99  
<TS 220 A
37 56 13 05C  
-0.13  
<TS 221 A
37 56 12 05H 0.94  
<TS 222 A
37 56 22 04H 1.03  
<TS 223 A
37 60 14 03H  
-0.9  
<TS 224 A
37 62 18 04H 0.94  
<TS 225 A
37 62 16 05H  
-0.81  
<TS 226 A
37 106 18 03C  
-0.79  
<TS 227 A
37 116 15 03C 0.87  
<TS 228 A
37 128 15 VS4  
-0.86  
<TS 229 A
37 128 20 VS4 0.82  
<TS 230 A
37 134 11 05H 0.88  
<TS 231 A
38 11 11 05H 0.87  
<TS 232 A
38 13 9
05C 0.89  
<TS 233 A
38 17 16 05H  
-0.15  
<TS 234 A
38 35 18 03H 0.88  
<TS 22 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 235     A       38       35       23       04H       0.86   <TS 236     A       38       35       20       05H       0.96   <TS 237     A       38       39       12       02C       0.82   <TS 238     A       38       45         12       03C       -0.94   <TS 239     A       38       47         9       03C       -0.2   <TS 240     A       38       47         12       02H       0.87   <TS 241     A       38       49         11       04C       0.88   <TS 242     A       38       49         13       DBC       1.49   <TS 243     A       38       51       30       04C       0.83   <TS 244     A       38       53       10       04H       0.89   <TS 245     A       38       53         9       05C       -0.97   <TS 246     A       38       59       13       05H       -0.17   <TS 247     A       38       59       15       04H       0.88   <TS 248     A       38       61         9       04H       -0.07   <TS 249     A       38       115       11       02C       0.87   <TS 250     A       38       115         5       02C       -0.9   <TS 251     A       38       119       13       02C       0.85   <TS 252     A       38       123       10       02C       -0.86   <TS 253     A       38       127       16       03H       0.92   <TS 254     A       39       10       14       DBH       1.94   <TS 255     A       39       14       13       05H       -0.19   <TS 256     A       39       26         6       04H         1   <TS 257     A       39       36         9       05H       -0.79   <TS 258     A       39       40         7       02H       0.96   <TS 259     A       39       42         11       04H       -0.77   <TS 260     A       39       42         12       03C       -0.99   <TS 261     A       39       46         12       04H       -0.79   <TS 262     A       39       58       12       04H       -0.91   <TS 263     A       39       62         9       05H       0.18   <TS 264     A       39       62         14       05H         1   <TS 265     A       39       104       12       04H       0.83   <TS 266     A       39       104       14       03C       -0.85   <TS 267     A       39       104       12       02C       -0.22   <TS 268     A       39       106         8       03C       -0.24   <TS 269     A       39       112       15       02C       0.94   <TS 270     A       39       120       19       04H       0.85   <TS 271     A       39       126       18       03C         0.9   <TS 272     A       39       130       11       DBC       -1.56   <TS 273     A       40         5       11       01C       -0.93   <TS 23 of 156
Percent No SG Row Column in Depth Location Elevation TS 235 A
38 35 23 04H 0.86  
<TS 236 A
38 35 20 05H 0.96  
<TS 237 A
38 39 12 02C 0.82  
<TS 238 A
38 45 12 03C  
-0.94  
<TS 239 A
38 47 9
03C  
-0.2  
<TS 240 A
38 47 12 02H 0.87  
<TS 241 A
38 49 11 04C 0.88  
<TS 242 A
38 49 13 DBC 1.49  
<TS 243 A
38 51 30 04C 0.83  
<TS 244 A
38 53 10 04H 0.89  
<TS 245 A
38 53 9
05C  
-0.97  
<TS 246 A
38 59 13 05H  
-0.17  
<TS 247 A
38 59 15 04H 0.88  
<TS 248 A
38 61 9
04H  
-0.07  
<TS 249 A
38 115 11 02C 0.87  
<TS 250 A
38 115 5
02C  
-0.9  
<TS 251 A
38 119 13 02C 0.85  
<TS 252 A
38 123 10 02C  
-0.86  
<TS 253 A
38 127 16 03H 0.92  
<TS 254 A
39 10 14 DBH 1.94  
<TS 255 A
39 14 13 05H  
-0.19  
<TS 256 A
39 26 6
04H 1  
<TS 257 A
39 36 9
05H  
-0.79  
<TS 258 A
39 40 7
02H 0.96  
<TS 259 A
39 42 11 04H  
-0.77  
<TS 260 A
39 42 12 03C  
-0.99  
<TS 261 A
39 46 12 04H  
-0.79  
<TS 262 A
39 58 12 04H  
-0.91  
<TS 263 A
39 62 9
05H 0.18  
<TS 264 A
39 62 14 05H 1  
<TS 265 A
39 104 12 04H 0.83  
<TS 266 A
39 104 14 03C  
-0.85  
<TS 267 A
39 104 12 02C  
-0.22  
<TS 268 A
39 106 8
03C  
-0.24  
<TS 269 A
39 112 15 02C 0.94  
<TS 270 A
39 120 19 04H 0.85  
<TS 271 A
39 126 18 03C 0.9  
<TS 272 A
39 130 11 DBC  
-1.56  
<TS 273 A
40 5
11 01C  
-0.93  
<TS 23 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Percent No   SG     Row   Column     in Depth Location Elevation TS 274     A       40         7         11       02C       0.91   <TS 275     A       40       35         12       02C       0.15   <TS 276     A       40       35         12       04H       0.87   <TS 277     A       40       49         12       04H       0.92   <TS 278     A       40       51         10       03H       -0.86   <TS 279     A       40       51         9       04H       0.84   <TS 280     A       40       51         8       03C       0.86   <TS 281     A       40       55         10       VS4       0.88   <TS 282     A       40       57         7       03H       0.95   <TS 283     A       40       59         15     05H         1.1   <TS 284     A       40       115         12     02C       0.83   <TS 285     A       40       117         10       03C       -0.24   <TS 286     A       40       125         15       02C       0.87   <TS 287     A       40       147         23       VS4       -0.15   <TS 288     A       40       147         28       VS4       -0.81   <TS 289     A       40       161         10       01H       0.84   <TS 290     A       41         6         13     02C       -0.11   <TS 291     A       41         8         12     02C       -0.17   <TS 292     A       41       16         12     05H       -0.85   <TS 293     A       41       20         11       05H       1.11   <TS 294     A       41       22         9       05H       -0.87   <TS 295     A       41       34         12       03H       -0.88   <TS 296     A       41       40         9       05C       -0.15   <TS 297     A       41       44         14       03C       -0.92   <TS 298     A       41       44         15       05C       -0.88   <TS 299     A       41       50         13       02C       -0.85   <TS 300     A       41       52         28       VS4       -0.9   <TS 301     A       41       52         11       03H         0.9   <TS 302     A       41       54         14       04C       -0.86   <TS 303     A       41       60         26       05H       0.92   <TS 304     A       41       60         9       04H       0.99   <TS 305     A       41       64         12       04H       0.89   <TS 306     A       41       108         15       03C       0.85   <TS 307     A       41       120         8       03C       0.94   <TS 308     A       41       126         14       02C       -0.85   <TS 309     A       41       160         12       03C       -0.15   <TS 310     A       41       160         9       03C       0.69   <TS 311     A       41       160         18       01H       0.88   <TS 312     A       42         5         12     02H       0.87   <TS 24 of 156
Percent No SG Row Column in Depth Location Elevation TS 274 A
40 7
11 02C 0.91  
<TS 275 A
40 35 12 02C 0.15  
<TS 276 A
40 35 12 04H 0.87  
<TS 277 A
40 49 12 04H 0.92  
<TS 278 A
40 51 10 03H  
-0.86  
<TS 279 A
40 51 9
04H 0.84  
<TS 280 A
40 51 8
03C 0.86  
<TS 281 A
40 55 10 VS4 0.88  
<TS 282 A
40 57 7
03H 0.95  
<TS 283 A
40 59 15 05H 1.1  
<TS 284 A
40 115 12 02C 0.83  
<TS 285 A
40 117 10 03C  
-0.24  
<TS 286 A
40 125 15 02C 0.87  
<TS 287 A
40 147 23 VS4  
-0.15  
<TS 288 A
40 147 28 VS4  
-0.81  
<TS 289 A
40 161 10 01H 0.84  
<TS 290 A
41 6
13 02C  
-0.11  
<TS 291 A
41 8
12 02C  
-0.17  
<TS 292 A
41 16 12 05H  
-0.85  
<TS 293 A
41 20 11 05H 1.11  
<TS 294 A
41 22 9
05H  
-0.87  
<TS 295 A
41 34 12 03H  
-0.88  
<TS 296 A
41 40 9
05C  
-0.15  
<TS 297 A
41 44 14 03C  
-0.92  
<TS 298 A
41 44 15 05C  
-0.88  
<TS 299 A
41 50 13 02C  
-0.85  
<TS 300 A
41 52 28 VS4  
-0.9  
<TS 301 A
41 52 11 03H 0.9  
<TS 302 A
41 54 14 04C  
-0.86  
<TS 303 A
41 60 26 05H 0.92  
<TS 304 A
41 60 9
04H 0.99  
<TS 305 A
41 64 12 04H 0.89  
<TS 306 A
41 108 15 03C 0.85  
<TS 307 A
41 120 8
03C 0.94  
<TS 308 A
41 126 14 02C  
-0.85  
<TS 309 A
41 160 12 03C  
-0.15  
<TS 310 A
41 160 9
03C 0.69  
<TS 311 A
41 160 18 01H 0.88  
<TS 312 A
42 5
12 02H 0.87  
<TS 24 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 313     A       42         5         12       VS4       -0.89   <TS 314     A       42         5         8       VS4       -0.16   <TS 315     A       42         7         21       02C       0.91   <TS 316     A       42         7         9       02C       0.11   <TS 317     A       42       33         8       DBH       -1.54   <TS 318     A       42       33         13       DBC       -1.43   <TS 319     A       42       35         11       05C       0.99   <TS 320     A       42       41         29       VS4       0.81   <TS 321     A       42       41         35       VS4         -1   <TS 322     A       42       43         9       03C       0.92   <TS 323     A       42       43         11       VS4       -0.97   <TS 324     A       42       43         19       04H       0.85   <TS 325     A       42       45         10       04H       0.85   <TS 326     A       42       45         14       02H       0.83   <TS 327     A       42       55         8       03H       -0.91   <TS 328     A       42       57         13       03H       0.92   <TS 329     A       42       59         16       04H       0.88   <TS 330     A       42       59         11       VS4       0.88   <TS 331     A       42       63         11       02H       0.83   <TS 332     A       42       117         15       02C       0.88   <TS 333     A       42       123         19       DBH       -0.11   <TS 334     A       43       36         11       VS4       1.09   <TS 335     A       43       44         11       04C       0.89   <TS 336     A       43       46         17       DBH       2.12   <TS 337     A       43       46         10       VS4       -0.09   <TS 338     A       43       46         10       03H       -0.86   <TS 339     A       43       46         28       VS4       -0.79   <TS 340     A       43       46         14       VS4       1.03   <TS 341     A       43       52         8       03H       -0.91   <TS 342     A       43       60         12       VS4       0.57   <TS 343     A       43       106         13       03C       0.74   <TS 344     A       43       126         31       VS4       0.98   <TS 345     A       43       126         11       DBC       1.58   <TS 346     A       44       15         12       DBH       -1.63   <TS 347     A       44       21         27       VS4       -0.79   <TS 348     A       44       21         23       VS4       -0.14   <TS 349     A       44       21         26       VS4       0.72   <TS 350     A       44       37         12       05C       -0.88   <TS 351     A       44       41         20       VS4       -0.36   <TS 25 of 156
Percent No SG Row Column in Depth Location Elevation TS 313 A
42 5
12 VS4  
-0.89  
<TS 314 A
42 5
8 VS4  
-0.16  
<TS 315 A
42 7
21 02C 0.91  
<TS 316 A
42 7
9 02C 0.11  
<TS 317 A
42 33 8
DBH  
-1.54  
<TS 318 A
42 33 13 DBC  
-1.43  
<TS 319 A
42 35 11 05C 0.99  
<TS 320 A
42 41 29 VS4 0.81  
<TS 321 A
42 41 35 VS4  
-1  
<TS 322 A
42 43 9
03C 0.92  
<TS 323 A
42 43 11 VS4  
-0.97  
<TS 324 A
42 43 19 04H 0.85  
<TS 325 A
42 45 10 04H 0.85  
<TS 326 A
42 45 14 02H 0.83  
<TS 327 A
42 55 8
03H  
-0.91  
<TS 328 A
42 57 13 03H 0.92  
<TS 329 A
42 59 16 04H 0.88  
<TS 330 A
42 59 11 VS4 0.88  
<TS 331 A
42 63 11 02H 0.83  
<TS 332 A
42 117 15 02C 0.88  
<TS 333 A
42 123 19 DBH  
-0.11  
<TS 334 A
43 36 11 VS4 1.09  
<TS 335 A
43 44 11 04C 0.89  
<TS 336 A
43 46 17 DBH 2.12  
<TS 337 A
43 46 10 VS4  
-0.09  
<TS 338 A
43 46 10 03H  
-0.86  
<TS 339 A
43 46 28 VS4  
-0.79  
<TS 340 A
43 46 14 VS4 1.03  
<TS 341 A
43 52 8
03H  
-0.91  
<TS 342 A
43 60 12 VS4 0.57  
<TS 343 A
43 106 13 03C 0.74  
<TS 344 A
43 126 31 VS4 0.98  
<TS 345 A
43 126 11 DBC 1.58  
<TS 346 A
44 15 12 DBH  
-1.63  
<TS 347 A
44 21 27 VS4  
-0.79  
<TS 348 A
44 21 23 VS4  
-0.14  
<TS 349 A
44 21 26 VS4 0.72  
<TS 350 A
44 37 12 05C  
-0.88  
<TS 351 A
44 41 20 VS4  
-0.36  
<TS 25 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 352     A       44       47         11         VS4     -0.69   <TS 353     A       44       49         23         05C     -0.88   <TS 354     A       44       49       30         VS4       -0.7   <TS 355     A       44       49       27         VS4     -0.15   <TS 356     A       44       49       19         04H       0.79   <TS 357     A       44       59         9         03H       0.84   <TS 358     A       44       109       15         03C       0.11   <TS 359     A       44       123       19         VS4     -0.72   <TS 360     A       44       123       21         VS4     -0.11   <TS 361     A       44       123       13         VS4       0.79   <TS 362     A       44       123       15         06H     -0.07   <TS 363     A       44       125       12         VS4     -0.57   <TS 364     A       44       127       13         03C     -0.22   <TS 365     A       44       127       10         03C     -1.05   <TS 366     A       44       129       12         03C       0.81   <TS 367     A       44       131       13         05C       0.87   <TS 368     A       44       143       14         05C       0.82   <TS 369     A       45         6       13         DBH         2   <TS 370     A       45       12       17         DBH         2   <TS 371     A       45       30       13         04H     -0.92   <TS 372     A       45       30       10         04H     -0.02   <TS 373     A       45       42       13         VS4       0.59   <TS 374     A       45       52       15         03H       0.88   <TS 375     A       45       60       13         06H       0.53   <TS 376     A       45       60       14         04H       0.92   <TS 377     A       45       62         9         05H       0.95   <TS 378     A       45       104       13     . 03C       0.83   <TS 379     A       45       104         9         02C       0.79   <TS 380     A       45       108       21         03C       0.83   <TS 381     A       45       122       15         03C     -0.85   <TS 382     A       45       124       10         02C     -0.83   <TS 383     A       45       124       15         VS4       0.88   <TS 384     A       45       128         9         03H     -0.17   <TS 385     A       45       132       12         03C     -0.88   <TS 386     A       45       134       17         03C       0.85   <TS 387     A       46         7       13         VS4       0.9   <TS 388     A       46       17       12         VS4     -0.22   <TS 389     A       46       37         8         03H       0.9   <TS 390     A       46       41         8         04H       0.92   <TS 26 of 156
Percent No SG Row Column in Depth Location Elevation TS 352 A
44 47 11 VS4  
-0.69  
<TS 353 A
44 49 23 05C  
-0.88  
<TS 354 A
44 49 30 VS4  
-0.7  
<TS 355 A
44 49 27 VS4  
-0.15  
<TS 356 A
44 49 19 04H 0.79  
<TS 357 A
44 59 9
03H 0.84  
<TS 358 A
44 109 15 03C 0.11  
<TS 359 A
44 123 19 VS4  
-0.72  
<TS 360 A
44 123 21 VS4  
-0.11  
<TS 361 A
44 123 13 VS4 0.79  
<TS 362 A
44 123 15 06H  
-0.07  
<TS 363 A
44 125 12 VS4  
-0.57  
<TS 364 A
44 127 13 03C  
-0.22  
<TS 365 A
44 127 10 03C  
-1.05  
<TS 366 A
44 129 12 03C 0.81  
<TS 367 A
44 131 13 05C 0.87  
<TS 368 A
44 143 14 05C 0.82  
<TS 369 A
45 6
13 DBH 2  
<TS 370 A
45 12 17 DBH 2  
<TS 371 A
45 30 13 04H  
-0.92  
<TS 372 A
45 30 10 04H  
-0.02  
<TS 373 A
45 42 13 VS4 0.59  
<TS 374 A
45 52 15 03H 0.88  
<TS 375 A
45 60 13 06H 0.53  
<TS 376 A
45 60 14 04H 0.92  
<TS 377 A
45 62 9
05H 0.95  
<TS 378 A
45 104 13 03C 0.83  
<TS 379 A
45 104 9
02C 0.79  
<TS 380 A
45 108 21 03C 0.83  
<TS 381 A
45 122 15 03C  
-0.85  
<TS 382 A
45 124 10 02C  
-0.83  
<TS 383 A
45 124 15 VS4 0.88  
<TS 384 A
45 128 9
03H  
-0.17  
<TS 385 A
45 132 12 03C  
-0.88  
<TS 386 A
45 134 17 03C 0.85  
<TS 387 A
46 7
13 VS4 0.9  
<TS 388 A
46 17 12 VS4  
-0.22  
<TS 389 A
46 37 8
03H 0.9  
<TS 390 A
46 41 8
04H 0.92  
<TS 26 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 391     A       46       47         15       02H         0.9   <TS 392     A       46       51         15       03H       0.86   <TS 393     A       46       53         27       VS4       -0.83   <TS 394     A       46       53         21       VS4       0.85   <TS 395     A       46       55         13     VS4       -0.9   <TS 396     A       46       55         18       VS4       0.88   <TS 397     A       46       57         12       VS4       0.92   <TS 398     A       46       65         26       VS4         0.9   <TS 399     A       46       69         15       VS4       -0.48   <TS 400     A       46       111         11       02C         0.9   <TS 401     A       46       111         7       02C       -0.9   <TS 402     A       46       125         13     VS4       -0.13   <TS 403     A       46       125         10       VS4       0.17   <TS 404     A       46       125         9       VS4       0.83   <TS 405     A       46       127         11       02C       0.88   <TS 406     A       46       141         15       04C       0.87   <TS 407     A       47         8         15       01H       -0.86   <TS 408     A       47       12         11       DBC       1.88   <TS 409     A       47       24         11       04H       -0.85   <TS 410     A       47       24         10       VS4         0.5   <TS 411     A       47       24         6       DBC       -1.55   <TS 412     A       47       34         13       03C       0.99   <TS 413     A       47       50         14       VS4       0.94   <TS 414     A       47       68         12       06H       0.75   <TS 415     A       47       70         17       04H       0.91   <TS 416     A       47       112         17       02C         0.9   <TS 417     A       47       122         33       VS4       0.79   <TS 418     A       47       122         27       VS4       0.17   <TS 419     A       47       124         23       VS4         0   <TS 420     A       47       124         26       VS4       0.79   <TS 421     A       47       124         10       VS4       -0.64   <TS 422     A       47       126         25       VS4       -0.8   <TS 423     A       47       126         26       VS4       -0.02   <TS 424     A       47       126         11       04C       0.09   <TS 425     A       48         7         24       01C       0.87   <TS 426     A       48       19         12       05H       -0.82   <TS 427     A       48       19         39       VS4       -0.9   <TS 428     A       48       19         29       VS4       0.81   <TS 429     A       48       21         27       VS4       -0.94   <TS 27 of 156
Percent No SG Row Column in Depth Location Elevation TS 391 A
46 47 15 02H 0.9  
<TS 392 A
46 51 15 03H 0.86  
<TS 393 A
46 53 27 VS4  
-0.83  
<TS 394 A
46 53 21 VS4 0.85  
<TS 395 A
46 55 13 VS4  
-0.9  
<TS 396 A
46 55 18 VS4 0.88  
<TS 397 A
46 57 12 VS4 0.92  
<TS 398 A
46 65 26 VS4 0.9  
<TS 399 A
46 69 15 VS4  
-0.48  
<TS 400 A
46 111 11 02C 0.9  
<TS 401 A
46 111 7
02C  
-0.9  
<TS 402 A
46 125 13 VS4  
-0.13  
<TS 403 A
46 125 10 VS4 0.17  
<TS 404 A
46 125 9
VS4 0.83  
<TS 405 A
46 127 11 02C 0.88  
<TS 406 A
46 141 15 04C 0.87  
<TS 407 A
47 8
15 01H  
-0.86  
<TS 408 A
47 12 11 DBC 1.88  
<TS 409 A
47 24 11 04H  
-0.85  
<TS 410 A
47 24 10 VS4 0.5  
<TS 411 A
47 24 6
DBC  
-1.55  
<TS 412 A
47 34 13 03C 0.99  
<TS 413 A
47 50 14 VS4 0.94  
<TS 414 A
47 68 12 06H 0.75  
<TS 415 A
47 70 17 04H 0.91  
<TS 416 A
47 112 17 02C 0.9  
<TS 417 A
47 122 33 VS4 0.79  
<TS 418 A
47 122 27 VS4 0.17  
<TS 419 A
47 124 23 VS4 0  
<TS 420 A
47 124 26 VS4 0.79  
<TS 421 A
47 124 10 VS4  
-0.64  
<TS 422 A
47 126 25 VS4  
-0.8  
<TS 423 A
47 126 26 VS4  
-0.02  
<TS 424 A
47 126 11 04C 0.09  
<TS 425 A
48 7
24 01C 0.87  
<TS 426 A
48 19 12 05H  
-0.82  
<TS 427 A
48 19 39 VS4  
-0.9  
<TS 428 A
48 19 29 VS4 0.81  
<TS 429 A
48 21 27 VS4  
-0.94  
<TS 27 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 430     A       48       29       14       04H       0.83   <TS 431     A       48       29       18       03C       0.91   <TS 432     A       48       37       16       06H       0.84   <TS 433     A       48       41         36       VS4       -0.92   <TS 434     A       48       41         15       VS4       0.92   <TS 435     A       48       43         35       VS4       -0.85   <TS 436     A       48       43         10       VS4       0.15   <TS 437     A       48       43       19       VS4       0.83   <TS 438     A       48       43         9       02H       0.86   <TS 439     A       48       45         9       06H       0.79   <TS 440     A       48       53       10       VS4       -0.92   <TS 441     A       48       55       11       04H       0.88   <TS 442     A       48       69         15       VS4       -0.81   <TS 443     A       48       69         35       VS4       0.92   <TS 444     A       48       97       30       VS4       0.88   <TS 445     A       48       111       13       02C       0.85   <TS 446     A       48       123       11       04C       0.76   <TS 447     A       48       125       17       02C       0.77   <TS 448     A       48       125       18       02C       0.13   <TS 449     A       48       133       10       02C       0.85   <TS 450     A       48       159         8       01H       0.9   <TS 451     A       48       159       12       01H       -0.04   <TS 452     A       48       159         6       01H       -0.83   <TS 453     A       49       10       19       VS4       0.9   <TS 454     A       49       16       17       02C       -1.05   <TS 455     A       49       20       30       VS4       -0.83   <TS 456     A       49       20       24       VS4       0.94   <TS 457     A       49       24       14       VS4       -0.86   <TS 458     A       49       28       11       03C       0.99   <TS 459     A       49       32         7       DBC       1.46   <TS 460     A       49       36       15       03C       0.93   <TS 461     A       49       66         10       VS4       -0.66   <TS 462     A       49       66         15       VS4       0.04   <TS 463     A       49       66         18       VS4       0.81   <TS 464     A       49       68         9       04H       -0.15   <TS 465     A       49       70       18       VS4       0.92   <TS 466     A       49       70       11       DBC       1.89   <TS 467     A       49       74       19       VS4       -0.88   <TS 468     A       49       74       14       DBC       1.78   <TS 28 of 156
Percent No SG Row Column in Depth Location Elevation TS 430 A
48 29 14 04H 0.83  
<TS 431 A
48 29 18 03C 0.91  
<TS 432 A
48 37 16 06H 0.84  
<TS 433 A
48 41 36 VS4  
-0.92  
<TS 434 A
48 41 15 VS4 0.92  
<TS 435 A
48 43 35 VS4  
-0.85  
<TS 436 A
48 43 10 VS4 0.15  
<TS 437 A
48 43 19 VS4 0.83  
<TS 438 A
48 43 9
02H 0.86  
<TS 439 A
48 45 9
06H 0.79  
<TS 440 A
48 53 10 VS4  
-0.92  
<TS 441 A
48 55 11 04H 0.88  
<TS 442 A
48 69 15 VS4  
-0.81  
<TS 443 A
48 69 35 VS4 0.92  
<TS 444 A
48 97 30 VS4 0.88  
<TS 445 A
48 111 13 02C 0.85  
<TS 446 A
48 123 11 04C 0.76  
<TS 447 A
48 125 17 02C 0.77  
<TS 448 A
48 125 18 02C 0.13  
<TS 449 A
48 133 10 02C 0.85  
<TS 450 A
48 159 8
01H 0.9  
<TS 451 A
48 159 12 01H  
-0.04  
<TS 452 A
48 159 6
01H  
-0.83  
<TS 453 A
49 10 19 VS4 0.9  
<TS 454 A
49 16 17 02C  
-1.05  
<TS 455 A
49 20 30 VS4  
-0.83  
<TS 456 A
49 20 24 VS4 0.94  
<TS 457 A
49 24 14 VS4  
-0.86  
<TS 458 A
49 28 11 03C 0.99  
<TS 459 A
49 32 7
DBC 1.46  
<TS 460 A
49 36 15 03C 0.93  
<TS 461 A
49 66 10 VS4  
-0.66  
<TS 462 A
49 66 15 VS4 0.04  
<TS 463 A
49 66 18 VS4 0.81  
<TS 464 A
49 68 9
04H  
-0.15  
<TS 465 A
49 70 18 VS4 0.92  
<TS 466 A
49 70 11 DBC 1.89  
<TS 467 A
49 74 19 VS4  
-0.88  
<TS 468 A
49 74 14 DBC 1.78  
<TS 28 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 469     A       49       92       16       DBC       1.79   <TS 470     A       49       92       13       03C       -0.96   <TS 471     A       49       94         7       VS4         0.9   <TS 472     A       49       94       11       03C       0.18   <TS 473     A       49       94       10       02C       0.86   <TS 474     A       49       96       14       03C       0.83   <TS 475     A       49       96       10       02C       -0.94   <TS 476     A       49       98         6       03C       0.86   <TS 477     A       49       98         7       02C       0.83   <TS 478     A       49       112       11       VS4       -0.61   <TS 479     A       49       112       17       VS4       -0.2   <TS 480     A       49       122         8       04C       0.81   <TS 481     A       49       122       10       04C       -0.99   <TS 482     A       49       130       10       02C       -0.98   <TS 483     A       49       132       15       02C       0.88   <TS 484     A       49       134       12       03C       -0.68   <TS 485     A       49       138         9       04H         -1   <TS 486     A       49       138         8       04H       -0.19   <TS 487     A       49       158       10       01H         0.8   <TS 488     A       50       17       13       VS4       -0.93   <TS 489     A       50       19       13       VS4       0.68   <TS 490     A       50       19         8       DBC       1.41   <TS 491     A       50       21       18       DBH       1.66   <TS 492     A       50       21         9       DBC       1.61   <TS 493     A       50       29       11       04C       0.81   <TS 494     A       50       29         7       05H       0.99   <TS 495     A       50       39       10       04H       0.89   <TS 496     A       50       45       11       03H       0.89   <TS 497     A       50       45       12       VS5       -0.86   <TS 498     A       50       49         6       05H       -0.78   <TS 499     A       50       51       12       03H         0.9   <TS 500     A       50       55       10       05H       0.95   <TS 501     A       50       57       16       04H       0.58   <TS 502     A       50       57       10       05H       0.99   <TS 503     A       50       65       13       02H       -0.89   <TS 504     A       50       71       10       03H       0.82   <TS 505     A       50       91       12       VS4       0.94   <TS 506     A       50       97       13       02C       0.86   <TS 507     A       50       105       12       04C       -0.93   <TS 29 of 156
Percent No SG Row Column in Depth Location Elevation TS 469 A
49 92 16 DBC 1.79  
<TS 470 A
49 92 13 03C  
-0.96  
<TS 471 A
49 94 7
VS4 0.9  
<TS 472 A
49 94 11 03C 0.18  
<TS 473 A
49 94 10 02C 0.86  
<TS 474 A
49 96 14 03C 0.83  
<TS 475 A
49 96 10 02C  
-0.94  
<TS 476 A
49 98 6
03C 0.86  
<TS 477 A
49 98 7
02C 0.83  
<TS 478 A
49 112 11 VS4  
-0.61  
<TS 479 A
49 112 17 VS4  
-0.2  
<TS 480 A
49 122 8
04C 0.81  
<TS 481 A
49 122 10 04C  
-0.99  
<TS 482 A
49 130 10 02C  
-0.98  
<TS 483 A
49 132 15 02C 0.88  
<TS 484 A
49 134 12 03C  
-0.68  
<TS 485 A
49 138 9
04H  
-1  
<TS 486 A
49 138 8
04H  
-0.19  
<TS 487 A
49 158 10 01H 0.8  
<TS 488 A
50 17 13 VS4  
-0.93  
<TS 489 A
50 19 13 VS4 0.68  
<TS 490 A
50 19 8
DBC 1.41  
<TS 491 A
50 21 18 DBH 1.66  
<TS 492 A
50 21 9
DBC 1.61  
<TS 493 A
50 29 11 04C 0.81  
<TS 494 A
50 29 7
05H 0.99  
<TS 495 A
50 39 10 04H 0.89  
<TS 496 A
50 45 11 03H 0.89  
<TS 497 A
50 45 12 VS5  
-0.86  
<TS 498 A
50 49 6
05H  
-0.78  
<TS 499 A
50 51 12 03H 0.9  
<TS 500 A
50 55 10 05H 0.95  
<TS 501 A
50 57 16 04H 0.58  
<TS 502 A
50 57 10 05H 0.99  
<TS 503 A
50 65 13 02H  
-0.89  
<TS 504 A
50 71 10 03H 0.82  
<TS 505 A
50 91 12 VS4 0.94  
<TS 506 A
50 97 13 02C 0.86  
<TS 507 A
50 105 12 04C  
-0.93  
<TS 29 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 508     A       50       115         9       03C       -0.85   <TS 509     A       50       123         16       04C       0.09   <TS 510     A       50       127         12       03C       -0.88   <TS 511     A       50       127         8       03C       0.17   <TS 512     A       50       153         17       VS5       0.83   <TS 513     A       50       157         21       VS3         0.7   <TS 514     A       50       157         35       VS3       -0.72   <TS 515     A       51       16         19       VS4       -0.84   <TS 516     A       51       18         6       DBC       -1.74   <TS 517     A       51       18         6       DBC       1.57   <TS 518     A       51       20         28       VS3       -0.8   <TS 519     A       51       20         12       VS5       -0.07   <TS 520     A       51       24         7       02C       -0.93   <TS 521     A       51       30         10       06H       -0.95   <TS 522     A       51       38         8       04H       -0.79   <TS 523     A       51       40         19       DBH       1.86   <TS 524     A       51       54         10       04H       0.92   <TS 525     A       51       60         7       04H       0.88   <TS 526     A       51       64         12       05H       0.88   <TS 527     A       51       66         12       04H       -0.89   <TS 528     A       51       66         11       05H       0.95   <TS 529     A       51       70         14       05H         0.9   <TS 530     A       51       90         15       04C       -0.18   <TS 531     A       51       92         14       02C       0.88   <TS 532     A       51       102         14       03C         0.9   <TS 533     A       51       104         10       04C       -0.88   <TS 534     A       51       108         10       03C       -0.99   <TS 535     A       51       116         8       04C       -0.17   <TS 536     A       51       116         7       05H       0.92   <TS 537     A       51       118         17       02C       -0.88   <TS 538     A       51       122         14       02C       -0.2   <TS 539     A       51       124         14       04C       -0.87   <TS 540     A       51       126         13       03C       -0.88   <TS 541     A       51       126         17       02C       0.09   <TS 542     A       51       126         12       02C       0.81   <TS 543     A       51       126         6       03C       0.96   <TS 544     A       51       134         12       VS3       -0.72   <TS 545     A       51       134         7       04C       0.11   <TS 546     A       51       134         7       04C       0.85   <TS 30 of 156
Percent No SG Row Column in Depth Location Elevation TS 508 A
50 115 9
03C  
-0.85  
<TS 509 A
50 123 16 04C 0.09  
<TS 510 A
50 127 12 03C  
-0.88  
<TS 511 A
50 127 8
03C 0.17  
<TS 512 A
50 153 17 VS5 0.83  
<TS 513 A
50 157 21 VS3 0.7  
<TS 514 A
50 157 35 VS3  
-0.72  
<TS 515 A
51 16 19 VS4  
-0.84  
<TS 516 A
51 18 6
DBC  
-1.74  
<TS 517 A
51 18 6
DBC 1.57  
<TS 518 A
51 20 28 VS3  
-0.8  
<TS 519 A
51 20 12 VS5  
-0.07  
<TS 520 A
51 24 7
02C  
-0.93  
<TS 521 A
51 30 10 06H  
-0.95  
<TS 522 A
51 38 8
04H  
-0.79  
<TS 523 A
51 40 19 DBH 1.86  
<TS 524 A
51 54 10 04H 0.92  
<TS 525 A
51 60 7
04H 0.88  
<TS 526 A
51 64 12 05H 0.88  
<TS 527 A
51 66 12 04H  
-0.89  
<TS 528 A
51 66 11 05H 0.95  
<TS 529 A
51 70 14 05H 0.9  
<TS 530 A
51 90 15 04C  
-0.18  
<TS 531 A
51 92 14 02C 0.88  
<TS 532 A
51 102 14 03C 0.9  
<TS 533 A
51 104 10 04C  
-0.88  
<TS 534 A
51 108 10 03C  
-0.99  
<TS 535 A
51 116 8
04C  
-0.17  
<TS 536 A
51 116 7
05H 0.92  
<TS 537 A
51 118 17 02C  
-0.88  
<TS 538 A
51 122 14 02C  
-0.2  
<TS 539 A
51 124 14 04C  
-0.87  
<TS 540 A
51 126 13 03C  
-0.88  
<TS 541 A
51 126 17 02C 0.09  
<TS 542 A
51 126 12 02C 0.81  
<TS 543 A
51 126 6
03C 0.96  
<TS 544 A
51 134 12 VS3  
-0.72  
<TS 545 A
51 134 7
04C 0.11  
<TS 546 A
51 134 7
04C 0.85  
<TS 30 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 547     A       51       154         11       VS5       -0.79   <TS 548     A       51       154         11       VS3       -1.05   <TS 549     A       52         9         9       01C       -0.97   <TS 550     A       52       19         8       06H       -0.22   <TS 551     A       52       23         11       02C       0.81   <TS 552     A       52       25         10       04H       0.98   <TS 553     A       52       31         16       03C       0.93   <TS 554     A       52       33         10       06H       0.88   <TS 555     A       52       53         11       03H       0.81   <TS 556     A       52       55         12       03H       -0.85   <TS 557     A       52       89         10     06C       0.88   <TS 558     A       52       89         8       03C       0.86   <TS 559     A       52       91         9       05H       -0.81   <TS 560     A       52       97         15       02C       -0.92   <TS 561     A       52       97         12       VS5       -0.73   <TS 562     A       52       109         9       04C       -0.98   <TS 563     A       52       111         20       02C       0.87   <TS 564     A       52       115         9       04C       -0.81   <TS 565     A       52       117         21       02C         0.9   <TS 566     A       52       125         12     VS5       -0.68   <TS 567     A       52       127         9       VS5       -0.7   <TS 568     A       52       149         14     VS4       -0.87   <TS 569     A       52       149         18       VS3       0.87   <TS 570     A       53       10         13       01H       -0.78   <TS 571     A       53       10         10       VS4       -0.84   <TS 572     A       53       10         9       01C       -0.2   <TS 573     A       53       10         15       01C       -0.97   <TS 574     A       53       24         7       DBH       -1.67   <TS 575     A       53       52         11       04H       -0.85   <TS 576     A       53       56         16       03H       0.85   <TS 577     A       53       80         7       02H       -0.91   <TS 578     A       53       80         8       03H       -0.97   <TS 579     A       53       80         9       03H       0.78   <TS 580     A       53       88         10       03C       -0.9   <TS 581     A       53       90         11       03C       0.53   <TS 582     A       53       92         16       03C       0.81   <TS 583     A       53       94         9       04C       0.83   <TS 584     A       53       94         8       03C       0.88   <TS 585     A       53       94         11       03C       0.15   <TS 31 of 156
Percent No SG Row Column in Depth Location Elevation TS 547 A
51 154 11 VS5  
-0.79  
<TS 548 A
51 154 11 VS3  
-1.05  
<TS 549 A
52 9
9 01C  
-0.97  
<TS 550 A
52 19 8
06H  
-0.22  
<TS 551 A
52 23 11 02C 0.81  
<TS 552 A
52 25 10 04H 0.98  
<TS 553 A
52 31 16 03C 0.93  
<TS 554 A
52 33 10 06H 0.88  
<TS 555 A
52 53 11 03H 0.81  
<TS 556 A
52 55 12 03H  
-0.85  
<TS 557 A
52 89 10 06C 0.88  
<TS 558 A
52 89 8
03C 0.86  
<TS 559 A
52 91 9
05H  
-0.81  
<TS 560 A
52 97 15 02C  
-0.92  
<TS 561 A
52 97 12 VS5  
-0.73  
<TS 562 A
52 109 9
04C  
-0.98  
<TS 563 A
52 111 20 02C 0.87  
<TS 564 A
52 115 9
04C  
-0.81  
<TS 565 A
52 117 21 02C 0.9  
<TS 566 A
52 125 12 VS5  
-0.68  
<TS 567 A
52 127 9
VS5  
-0.7  
<TS 568 A
52 149 14 VS4  
-0.87  
<TS 569 A
52 149 18 VS3 0.87  
<TS 570 A
53 10 13 01H  
-0.78  
<TS 571 A
53 10 10 VS4  
-0.84  
<TS 572 A
53 10 9
01C  
-0.2  
<TS 573 A
53 10 15 01C  
-0.97  
<TS 574 A
53 24 7
DBH  
-1.67  
<TS 575 A
53 52 11 04H  
-0.85  
<TS 576 A
53 56 16 03H 0.85  
<TS 577 A
53 80 7
02H  
-0.91  
<TS 578 A
53 80 8
03H  
-0.97  
<TS 579 A
53 80 9
03H 0.78  
<TS 580 A
53 88 10 03C  
-0.9  
<TS 581 A
53 90 11 03C 0.53  
<TS 582 A
53 92 16 03C 0.81  
<TS 583 A
53 94 9
04C 0.83  
<TS 584 A
53 94 8
03C 0.88  
<TS 585 A
53 94 11 03C 0.15  
<TS 31 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth Location Elevation TS 586     A       53       100         10       02C       -0.92   <TS 587     A       53       104         12       03C       0.85   <TS 588     A       53       112         9       04C       -0.9   <TS 589     A       53       118         15       02C       0.85   <TS 590     A       53       122         10       04C       0.87   <TS 591     A       53       122         19       02C       -0.13   <TS 592     A       53       122         5       04C       -0.92   <TS 593     A       53       136         6       DBC       1.77   <TS 594     A       53       142         13       03C       0.46   <TS 595     A       54         9         11       01C       -0.15   <TS 596     A       54       21           8       DBC       1.43   <TS 597     A       54       21           7       06H       -0.22   <TS 598     A       54       23           9       03H       0.83   <TS 599     A       54       29         16       02C       0.73   <TS 600     A       54       33         12       03H       0.85   <TS 601     A       54       39           9       05H       0.88   <TS 602     A       54       39           9       03H         0.9   <TS 603     A       54       63           9       02H       0.84   <TS 604     A       54       81         20       DBH       1.48   <TS 605     A       54       83           9       02H         0.9   <TS 606     A       54       83         15       03H       0.98   <TS 607     A       54       83         11       04H       -0.06   <TS 608     A       54       83         17       DBH       -0.35   <TS 609     A       54       93           8       04C       -0.9   <TS 610     A       54       93           8       03C       0.88   <TS 611     A       54       93         13       02C         0.9   <TS 612     A       54       95         10       02C       -0.9   <TS 613     A       54       99         11       VS4       0.86   <TS 614     A       54       105         15       02C       0.85   <TS 615     A       54       109         11       04C       0.92   <TS 616     A       54       119         14       02C       0.89   <TS 617     A       54       139         8       DBC       1.75   <TS 618     A       54       143         12       04C         0.9   <TS 619     A       55         8         15       01C       -0.22   <TS 620     A       55       38           6       05C       -0.09   <TS 621     A       55       46         13       04H       -0.93   <TS 622     A       55       78           9       04H       0.91   <TS 623     A       55       80           9       02H       0.89   <TS 624     A       55       82         12       02H       -0.89   <TS 32 of 156
Percent No SG Row Column in Depth Location Elevation TS 586 A
53 100 10 02C  
-0.92  
<TS 587 A
53 104 12 03C 0.85  
<TS 588 A
53 112 9
04C  
-0.9  
<TS 589 A
53 118 15 02C 0.85  
<TS 590 A
53 122 10 04C 0.87  
<TS 591 A
53 122 19 02C  
-0.13  
<TS 592 A
53 122 5
04C  
-0.92  
<TS 593 A
53 136 6
DBC 1.77  
<TS 594 A
53 142 13 03C 0.46  
<TS 595 A
54 9
11 01C  
-0.15  
<TS 596 A
54 21 8
DBC 1.43  
<TS 597 A
54 21 7
06H  
-0.22  
<TS 598 A
54 23 9
03H 0.83  
<TS 599 A
54 29 16 02C 0.73  
<TS 600 A
54 33 12 03H 0.85  
<TS 601 A
54 39 9
05H 0.88  
<TS 602 A
54 39 9
03H 0.9  
<TS 603 A
54 63 9
02H 0.84  
<TS 604 A
54 81 20 DBH 1.48  
<TS 605 A
54 83 9
02H 0.9  
<TS 606 A
54 83 15 03H 0.98  
<TS 607 A
54 83 11 04H  
-0.06  
<TS 608 A
54 83 17 DBH  
-0.35  
<TS 609 A
54 93 8
04C  
-0.9  
<TS 610 A
54 93 8
03C 0.88  
<TS 611 A
54 93 13 02C 0.9  
<TS 612 A
54 95 10 02C  
-0.9  
<TS 613 A
54 99 11 VS4 0.86  
<TS 614 A
54 105 15 02C 0.85  
<TS 615 A
54 109 11 04C 0.92  
<TS 616 A
54 119 14 02C 0.89  
<TS 617 A
54 139 8
DBC 1.75  
<TS 618 A
54 143 12 04C 0.9  
<TS 619 A
55 8
15 01C  
-0.22  
<TS 620 A
55 38 6
05C  
-0.09  
<TS 621 A
55 46 13 04H  
-0.93  
<TS 622 A
55 78 9
04H 0.91  
<TS 623 A
55 80 9
02H 0.89  
<TS 624 A
55 82 12 02H  
-0.89  
<TS 32 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 625     A       55       84         9       02C       0.11   <TS 626     A       55       86         10       DBH       1.98   <TS 627     A       55       88         13       02C       -0.9   <TS 628     A       55       96         10       03C       -0.92   <TS 629     A       55       96         11       02C       -0.22   <TS 630     A       55       106         12       06H       0.88   <TS 631     A       55       112         9       03C       -0.13   <TS 632     A       55       112         10       04C       -0.94   <TS 633     A       55       114         14       02C       0.83   <TS 634     A       55       114         10       03C       0.77   <TS 635     A       55       114         7       03C       -0.96   <TS 636     A       55       120         12       02C       -0.23   <TS 637     A       55       122         14       02C       -0.15   <TS 638     A       55       140         19       06C       -0.09   <TS 639     A       56       27         11       03H       -0.89   <TS 640     A       56       29         9       06H       -0.81   <TS 641     A       56       33         9       03H       -0.89   <TS 642     A       56       39         11       04H       -0.09   <TS 643     A       56       41         11       02H       -0.13   <TS 644     A       56       59         10       03H       0.86   <TS 645     A       56       59         10       04H       0.88   <TS 646     A       56       81         17       DBH       1.79   <TS 647     A       56       83         7       04C       0.86   <TS 648     A       56       115         13       03C       -0.92   <TS 649     A       56       115         18       02C       0.83   <TS 650     A       56       137         17       03C       0.13   <TS 651     A       56       141         13       04C       0.94   <TS 652     A       57       10         12       01C       -0.18   <TS 653     A       57       18         13       VS3       -0.92   <TS 654     A       57       32         10       06H       -0.09   <TS 655     A       57       64         12       02H       0.95   <TS 656     A       57       90         9       03C       -0.2   <TS 657     A       57       90         10       04C       -0.2   <TS 658     A       57       110         13       02C       0.86   <TS 659     A       57       110         8       02C       -0.18   <TS 660     A       57       114         12       03C       -0.9   <TS 661     A       57       136         9       03C       -0.81   <TS 662     A       57       138         11       02C       0.88   <TS 663     A       57       142         14       04C       -0.94   <TS 33 of 156
Percent No SG Row Column in Depth Location Elevation TS 625 A
55 84 9
02C 0.11  
<TS 626 A
55 86 10 DBH 1.98  
<TS 627 A
55 88 13 02C  
-0.9  
<TS 628 A
55 96 10 03C  
-0.92  
<TS 629 A
55 96 11 02C  
-0.22  
<TS 630 A
55 106 12 06H 0.88  
<TS 631 A
55 112 9
03C  
-0.13  
<TS 632 A
55 112 10 04C  
-0.94  
<TS 633 A
55 114 14 02C 0.83  
<TS 634 A
55 114 10 03C 0.77  
<TS 635 A
55 114 7
03C  
-0.96  
<TS 636 A
55 120 12 02C  
-0.23  
<TS 637 A
55 122 14 02C  
-0.15  
<TS 638 A
55 140 19 06C  
-0.09  
<TS 639 A
56 27 11 03H  
-0.89  
<TS 640 A
56 29 9
06H  
-0.81  
<TS 641 A
56 33 9
03H  
-0.89  
<TS 642 A
56 39 11 04H  
-0.09  
<TS 643 A
56 41 11 02H  
-0.13  
<TS 644 A
56 59 10 03H 0.86  
<TS 645 A
56 59 10 04H 0.88  
<TS 646 A
56 81 17 DBH 1.79  
<TS 647 A
56 83 7
04C 0.86  
<TS 648 A
56 115 13 03C  
-0.92  
<TS 649 A
56 115 18 02C 0.83  
<TS 650 A
56 137 17 03C 0.13  
<TS 651 A
56 141 13 04C 0.94  
<TS 652 A
57 10 12 01C  
-0.18  
<TS 653 A
57 18 13 VS3  
-0.92  
<TS 654 A
57 32 10 06H  
-0.09  
<TS 655 A
57 64 12 02H 0.95  
<TS 656 A
57 90 9
03C  
-0.2  
<TS 657 A
57 90 10 04C  
-0.2  
<TS 658 A
57 110 13 02C 0.86  
<TS 659 A
57 110 8
02C  
-0.18  
<TS 660 A
57 114 12 03C  
-0.9  
<TS 661 A
57 136 9
03C  
-0.81  
<TS 662 A
57 138 11 02C 0.88  
<TS 663 A
57 142 14 04C  
-0.94  
<TS 33 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 664     A       57       142         13       04C       -0.13   <TS 665     A       57       142         16       03C       0.87   <TS 666     A       58       33         15       DBH       1.62   <TS 667     A       58       33         11       04H       -0.87   <TS 668     A       58       57         7       04H         0.9   <TS 669     A       58       57         7       03H       1.03   <TS 670     A       58       81         10       03H         0   <TS 671     A       58       81         10       02H       -0.15   <TS 672     A       58       85         12       03H       0.91   <TS 673     A       58       85         8       02H       -0.89   <TS 674     A       58       87         15       02C       -0.77   <TS 675     A       58       105         8       05H         0   <TS 676     A       58       113         10       04C         0.9   <TS 677     A       58       115         10       04C       0.88   <TS 678     A       58       121         10       03C       0.78   <TS 679     A       58       121         13       02C       0.83   <TS 680     A       58       123         10       03C         0   <TS 681     A       58       127         22       04C       0.83   <TS 682     A       58       127         8       04C         0   <TS 683     A       58       143         11       03C       0.82   <TS 684     A       59       30         15       03C       0.78   <TS 685     A       59       30         6       03H       0.94   <TS 686     A       59       30         10       03H       -0.89   <TS 687     A       59       38         11       03H       0.81   <TS 688     A       59       50         13       06H       0.87   <TS 689     A       59       56         14       DBH       -0.92   <TS 690     A       59       56         10       VS4       0.83   <TS 691     A       59       60           7       04H       0.85   <TS 692     A       59       66         14       06C       0.86   <TS 693     A       59       70         7       03H       -0.82   <TS 694     A       59       70         9       03H       0.95   <TS 695     A       59       82         15       03H       0.79   <TS 696     A       59       90         13       02C       -0.92   <TS 697     A       59       106         14       02C       0.81   <TS 698     A       59       114         11       03C       -1.03   <TS 699     A       59       114         15       03C       0.77   <TS 700     A       59       118         10       02C       -0.24   <TS 701     A       59       118         11       02C       0.83   <TS 702     A       59       120         11       02C       -0.88   <TS 34 of 156
Percent No SG Row Column in Depth Location Elevation TS 664 A
57 142 13 04C  
-0.13  
<TS 665 A
57 142 16 03C 0.87  
<TS 666 A
58 33 15 DBH 1.62  
<TS 667 A
58 33 11 04H  
-0.87  
<TS 668 A
58 57 7
04H 0.9  
<TS 669 A
58 57 7
03H 1.03  
<TS 670 A
58 81 10 03H 0  
<TS 671 A
58 81 10 02H  
-0.15  
<TS 672 A
58 85 12 03H 0.91  
<TS 673 A
58 85 8
02H  
-0.89  
<TS 674 A
58 87 15 02C  
-0.77  
<TS 675 A
58 105 8
05H 0  
<TS 676 A
58 113 10 04C 0.9  
<TS 677 A
58 115 10 04C 0.88  
<TS 678 A
58 121 10 03C 0.78  
<TS 679 A
58 121 13 02C 0.83  
<TS 680 A
58 123 10 03C 0  
<TS 681 A
58 127 22 04C 0.83  
<TS 682 A
58 127 8
04C 0  
<TS 683 A
58 143 11 03C 0.82  
<TS 684 A
59 30 15 03C 0.78  
<TS 685 A
59 30 6
03H 0.94  
<TS 686 A
59 30 10 03H  
-0.89  
<TS 687 A
59 38 11 03H 0.81  
<TS 688 A
59 50 13 06H 0.87  
<TS 689 A
59 56 14 DBH  
-0.92  
<TS 690 A
59 56 10 VS4 0.83  
<TS 691 A
59 60 7
04H 0.85  
<TS 692 A
59 66 14 06C 0.86  
<TS 693 A
59 70 7
03H  
-0.82  
<TS 694 A
59 70 9
03H 0.95  
<TS 695 A
59 82 15 03H 0.79  
<TS 696 A
59 90 13 02C  
-0.92  
<TS 697 A
59 106 14 02C 0.81  
<TS 698 A
59 114 11 03C  
-1.03  
<TS 699 A
59 114 15 03C 0.77  
<TS 700 A
59 118 10 02C  
-0.24  
<TS 701 A
59 118 11 02C 0.83  
<TS 702 A
59 120 11 02C  
-0.88  
<TS 34 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 703     A       59       126         11       06H       0.85   <TS 704     A       59       144         13       04C       0.89   <TS 705     A       60       11         11       01C       0.13   <TS 706     A       60       25         14       04H       0.86   <TS 707     A       60       27         10       03C       0.85   <TS 708     A       60       29         18       04H       0.94   <TS 709     A       60       31         10       03H       0.87   <TS 710     A       60       33         16       DBC       1.49   <TS 711     A       60       39         12       04H       0.92   <TS 712     A       60       39         9       05H       -0.06   <TS 713     A       60       39         14       06H       0.94   <TS 714     A       60       83         10       DBH       -1.89   <TS 715     A       60       85         11       02C         0.9   <TS 716     A       60       103         11       05H       0.93   <TS 717     A       60       119         21       02C       0.88   <TS 718     A       60       121         20       02C         0.9   <TS 719     A       61       20         11       DBC       1.43   <TS 720     A       61       34         13       03H       0.87   <TS 721     A       61       34         8       04H       0.91   <TS 722     A       61       36         9       03H       -0.78   <TS 723     A       61       40         10       04H       0.85   <TS 724     A       61       44         12       04H       -0.13   <TS 725     A       61       48         13       06H       0.86   <TS 726     A       61       54         10       03H       -0.85   <TS 727     A       61       56         10       03H       -0.98   <TS 728     A       61       86         12       03C       -0.13   <TS 729     A       61       104         7       02C       -0.9   <TS 730     A       61       108         10       03H       -0.88   <TS 731     A       61       112         15       04C       -0.97   <TS 732     A       61       120         11       VS4       -0.92   <TS 733     A       61       120         11       04C       -0.91   <TS 734     A       61       120         10       03C       0.95   <TS 735     A       61       138         14       DBC       1.45   <TS 736     A       61       138         13       04C       0.94   <TS 737     A       61       144         10       DBH         1.8   <TS 738     A       61       150         13       DBC       1.16   <TS 739     A       62       11         14       01C       -0.95   <TS 740     A       62       15         10       06C       0.79   <TS 741     A       62       19         12       06H       1.04   <TS 35 of 156
Percent No SG Row Column in Depth Location Elevation TS 703 A
59 126 11 06H 0.85  
<TS 704 A
59 144 13 04C 0.89  
<TS 705 A
60 11 11 01C 0.13  
<TS 706 A
60 25 14 04H 0.86  
<TS 707 A
60 27 10 03C 0.85  
<TS 708 A
60 29 18 04H 0.94  
<TS 709 A
60 31 10 03H 0.87  
<TS 710 A
60 33 16 DBC 1.49  
<TS 711 A
60 39 12 04H 0.92  
<TS 712 A
60 39 9
05H  
-0.06  
<TS 713 A
60 39 14 06H 0.94  
<TS 714 A
60 83 10 DBH  
-1.89  
<TS 715 A
60 85 11 02C 0.9  
<TS 716 A
60 103 11 05H 0.93  
<TS 717 A
60 119 21 02C 0.88  
<TS 718 A
60 121 20 02C 0.9  
<TS 719 A
61 20 11 DBC 1.43  
<TS 720 A
61 34 13 03H 0.87  
<TS 721 A
61 34 8
04H 0.91  
<TS 722 A
61 36 9
03H  
-0.78  
<TS 723 A
61 40 10 04H 0.85  
<TS 724 A
61 44 12 04H  
-0.13  
<TS 725 A
61 48 13 06H 0.86  
<TS 726 A
61 54 10 03H  
-0.85  
<TS 727 A
61 56 10 03H  
-0.98  
<TS 728 A
61 86 12 03C  
-0.13  
<TS 729 A
61 104 7
02C  
-0.9  
<TS 730 A
61 108 10 03H  
-0.88  
<TS 731 A
61 112 15 04C  
-0.97  
<TS 732 A
61 120 11 VS4  
-0.92  
<TS 733 A
61 120 11 04C  
-0.91  
<TS 734 A
61 120 10 03C 0.95  
<TS 735 A
61 138 14 DBC 1.45  
<TS 736 A
61 138 13 04C 0.94  
<TS 737 A
61 144 10 DBH 1.8  
<TS 738 A
61 150 13 DBC 1.16  
<TS 739 A
62 11 14 01C  
-0.95  
<TS 740 A
62 15 10 06C 0.79  
<TS 741 A
62 19 12 06H 1.04  
<TS 35 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 742     A       62       33       19       03H       0.92   <TS 743     A       62       35       13       03H         0.9   <TS 744     A       62       49         15       05H       0.91   <TS 745     A       62       59         9       04H       0.85   <TS 746     A       62       73       11       04H       -0.09   <TS 747     A       62       89         10       03C       -1.04   <TS 748     A       62       95         9       04C       -0.94   <TS 749     A       62       109       11       04H       -0.79   <TS 750     A       62       111       10       03H       0.19   <TS 751     A       62       121       13       02C       0.88   <TS 752     A       63       12       13       o1C       -0.93   <TS 753     A       63       40         7       DBC       -1.5   <TS 754     A       63       44       12       06C       -0.88   <TS 755     A       63       52       16       06C       0.88   <TS 756     A       63       58       11       03H       0.91   <TS 757     A       63       60         11       03H       0.97   <TS 758     A       63       62       12       04C       0.81   <TS 759     A       63       66       12       04H       -0.95   <TS 760     A       63       80       11       03H       0.93   <TS 761     A       63       82       10       06H       0.83   <TS 762     A       63       82       22       03H       0.89   <TS 763     A       63       82         8       02H       -0.92   <TS 764     A       63       84       10       DBH       -1.82   <TS 765     A       63       86       14       03C       -0.92   <TS 766     A       63       86       10       05C       0.86   <TS 767     A       63       86         15       02C       -0.88   <TS 768     A       63       102       14       04H       0.86   <TS 769     A       63       104       16       03C       0.85   <TS 770     A       63       104       12       04C       -0.22   <TS 771     A       63       104       11       05C       -0.9   <TS 772     A       63       106       15       03H       0.94   <TS 773     A       63       118       18       03C         0.9   <TS 774     A       63       122       20       03C       0.85   <TS 775     A       63       124       15       04C       0.87   <TS 776     A       63       124         8       04C       -0.15   <TS 777     A       63       126       16       04C       0.85   <TS 778     A       63       134       10       05C       0.92   <TS 779     A       63       134       13       03C         0.9   <TS 780     A       63       136       14       03C       -0.89   <TS 36 of 156
Percent No SG Row Column in Depth Location Elevation TS 742 A
62 33 19 03H 0.92  
<TS 743 A
62 35 13 03H 0.9  
<TS 744 A
62 49 15 05H 0.91  
<TS 745 A
62 59 9
04H 0.85  
<TS 746 A
62 73 11 04H  
-0.09  
<TS 747 A
62 89 10 03C  
-1.04  
<TS 748 A
62 95 9
04C  
-0.94  
<TS 749 A
62 109 11 04H  
-0.79  
<TS 750 A
62 111 10 03H 0.19  
<TS 751 A
62 121 13 02C 0.88  
<TS 752 A
63 12 13 o1C  
-0.93  
<TS 753 A
63 40 7
DBC  
-1.5  
<TS 754 A
63 44 12 06C  
-0.88  
<TS 755 A
63 52 16 06C 0.88  
<TS 756 A
63 58 11 03H 0.91  
<TS 757 A
63 60 11 03H 0.97  
<TS 758 A
63 62 12 04C 0.81  
<TS 759 A
63 66 12 04H  
-0.95  
<TS 760 A
63 80 11 03H 0.93  
<TS 761 A
63 82 10 06H 0.83  
<TS 762 A
63 82 22 03H 0.89  
<TS 763 A
63 82 8
02H  
-0.92  
<TS 764 A
63 84 10 DBH  
-1.82  
<TS 765 A
63 86 14 03C  
-0.92  
<TS 766 A
63 86 10 05C 0.86  
<TS 767 A
63 86 15 02C  
-0.88  
<TS 768 A
63 102 14 04H 0.86  
<TS 769 A
63 104 16 03C 0.85  
<TS 770 A
63 104 12 04C  
-0.22  
<TS 771 A
63 104 11 05C  
-0.9  
<TS 772 A
63 106 15 03H 0.94  
<TS 773 A
63 118 18 03C 0.9  
<TS 774 A
63 122 20 03C 0.85  
<TS 775 A
63 124 15 04C 0.87  
<TS 776 A
63 124 8
04C  
-0.15  
<TS 777 A
63 126 16 04C 0.85  
<TS 778 A
63 134 10 05C 0.92  
<TS 779 A
63 134 13 03C 0.9  
<TS 780 A
63 136 14 03C  
-0.89  
<TS 36 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 781     A       63       136         15       06H       -0.61   <TS 782     A       63       140         17       DBC       1.91   <TS 783     A       63       142         15       04C       0.88   <TS 784     A       64       11         30       VS4       -0.95   <TS 785     A       64       11         8       VS4       0.62   <TS 786     A       64       11         12       06H       0.84   <TS 787     A       64       11         18       VS5       0.71   <TS 788     A       64       13         15       04H       0.96   <TS 789     A       64       13         20       VS4       -0.93   <TS 790     A       64       19         7       06H         0   <TS 791     A       64       25         12       06C       0.84   <TS 792     A       64       29         10       DBC       1.74   <TS 793     A       64       37         12       VS3       0.24   <TS 794     A       64       37         10       VS4       -0.88   <TS 795     A       64       37         17       VS5         0.8   <TS 796     A       64       57         10       05H       0.89   <TS 797     A       64       57         14       06C       0.85   <TS 798     A       64       59         11       05C       0.92   <TS 799     A       64       59         6       04C       0.86   <TS 800     A       64       67         9       06C       -0.18   <TS 801     A       64       71         14       VS5       0.86   <TS 802     A       64       71         14       VS5       -0.9   <TS 803     A       64       83         13       03H       0.97   <TS 804     A       64       111         11       02H       0.92   <TS 805     A       64       123         16       04C       0.87   <TS 806     A       64       139         12       03C       0.96   <TS 807     A       64       153         11       01C       -0.93   <TS 808     A       65       12         20       06H       0.84   <TS 809     A       65       14         10       06H       0.81   <TS 810     A       65       16         12       05H       0.85   <TS 811     A       65       24         14       VS5       0.64   <TS 812     A       65       24         7       VS5       -0.82   <TS 813     A       65       32         8       DBC       -1.55   <TS 814     A       65       32         9       DBC       1.66   <TS 815     A       65       32         10       04H       0.87   <TS 816     A       65       40         12       03H       0.91   <TS 817     A       65       56         14       06C       0.86   <TS 818     A       65       56         10       03C       -0.92   <TS 819     A       65       60         10       02H       -0.91   <TS 37 of 156
Percent No SG Row Column in Depth Location Elevation TS 781 A
63 136 15 06H  
-0.61  
<TS 782 A
63 140 17 DBC 1.91  
<TS 783 A
63 142 15 04C 0.88  
<TS 784 A
64 11 30 VS4  
-0.95  
<TS 785 A
64 11 8
VS4 0.62  
<TS 786 A
64 11 12 06H 0.84  
<TS 787 A
64 11 18 VS5 0.71  
<TS 788 A
64 13 15 04H 0.96  
<TS 789 A
64 13 20 VS4  
-0.93  
<TS 790 A
64 19 7
06H 0  
<TS 791 A
64 25 12 06C 0.84  
<TS 792 A
64 29 10 DBC 1.74  
<TS 793 A
64 37 12 VS3 0.24  
<TS 794 A
64 37 10 VS4  
-0.88  
<TS 795 A
64 37 17 VS5 0.8  
<TS 796 A
64 57 10 05H 0.89  
<TS 797 A
64 57 14 06C 0.85  
<TS 798 A
64 59 11 05C 0.92  
<TS 799 A
64 59 6
04C 0.86  
<TS 800 A
64 67 9
06C  
-0.18  
<TS 801 A
64 71 14 VS5 0.86  
<TS 802 A
64 71 14 VS5  
-0.9  
<TS 803 A
64 83 13 03H 0.97  
<TS 804 A
64 111 11 02H 0.92  
<TS 805 A
64 123 16 04C 0.87  
<TS 806 A
64 139 12 03C 0.96  
<TS 807 A
64 153 11 01C  
-0.93  
<TS 808 A
65 12 20 06H 0.84  
<TS 809 A
65 14 10 06H 0.81  
<TS 810 A
65 16 12 05H 0.85  
<TS 811 A
65 24 14 VS5 0.64  
<TS 812 A
65 24 7
VS5  
-0.82  
<TS 813 A
65 32 8
DBC  
-1.55  
<TS 814 A
65 32 9
DBC 1.66  
<TS 815 A
65 32 10 04H 0.87  
<TS 816 A
65 40 12 03H 0.91  
<TS 817 A
65 56 14 06C 0.86  
<TS 818 A
65 56 10 03C  
-0.92  
<TS 819 A
65 60 10 02H  
-0.91  
<TS 37 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 820     A       65       60         7       04H       -0.86   <TS 821     A       65       60       10       03C       0.88   <TS 822     A       65       62       12       05C       -0.92   <TS 823     A       65       66       13       06H         0.9   <TS 824     A       65       76       11       02H       -0.19   <TS 825     A       65       88       10       02C       -0.9   <TS 826     A       65       90       13       02C       0.88   <TS 827     A       65       92       11       03C       0.81   <TS 828     A       65       92         8       02C       1.01   <TS 829     A       65       104       10       03H       0.48   <TS 830     A       65       104         6       04H       0.84   <TS 831     A       65       106       12       06C       0.88   <TS 832     A       65       106       18       04C       0.83   <TS 833     A       65       106       13       03C       0.85   <TS 834     A       65       106       17       02C       0.87   <TS 835     A       65       106         8       01C       0.13   <TS 836     A       65       108       17       03H       -0.9   <TS 837     A       65       110       13       03H       -0.86   <TS 838     A       65       116       14       VS3       0.85   <TS 839     A       65       120       11       03C       0.88   <TS 840     A       65       120       10       03C       -0.98   <TS 841     A       65       124         7       03C         1   <TS 842     A       65       126       17       06C       -0.9   <TS 843     A       65       138       26       04C       -0.13   <TS 844     A       65       152       20       VS3       0.98   <TS 845     A       66       13       10       VS4       -0.86   <TS 846     A       66       13       10       01C       -0.88   <TS 847     A       66       25       12       04H       0.87   <TS 848     A       66       27       15       06C       0.82   <TS 849     A       66       31       10       05H       -0.91   <TS 850     A       66       31       18       04H       0.93   <TS 851     A       66       35       13       04H       0.86   <TS 852     A       66       35       12       03H         0.9   <TS 853     A       66       37         9       06H       -0.09   <TS 854     A       66       39         7       05H       0.92   <TS 855     A       66       45       10       05H       0.99   <TS 856     A       66       49         9       05H         1   <TS 857     A       66       55       12       02H       0.88   <TS 858     A       66       59       14       06C       0.77   <TS 38 of 156
Percent No SG Row Column in Depth Location Elevation TS 820 A
65 60 7
04H  
-0.86  
<TS 821 A
65 60 10 03C 0.88  
<TS 822 A
65 62 12 05C  
-0.92  
<TS 823 A
65 66 13 06H 0.9  
<TS 824 A
65 76 11 02H  
-0.19  
<TS 825 A
65 88 10 02C  
-0.9  
<TS 826 A
65 90 13 02C 0.88  
<TS 827 A
65 92 11 03C 0.81  
<TS 828 A
65 92 8
02C 1.01  
<TS 829 A
65 104 10 03H 0.48  
<TS 830 A
65 104 6
04H 0.84  
<TS 831 A
65 106 12 06C 0.88  
<TS 832 A
65 106 18 04C 0.83  
<TS 833 A
65 106 13 03C 0.85  
<TS 834 A
65 106 17 02C 0.87  
<TS 835 A
65 106 8
01C 0.13  
<TS 836 A
65 108 17 03H  
-0.9  
<TS 837 A
65 110 13 03H  
-0.86  
<TS 838 A
65 116 14 VS3 0.85  
<TS 839 A
65 120 11 03C 0.88  
<TS 840 A
65 120 10 03C  
-0.98  
<TS 841 A
65 124 7
03C 1  
<TS 842 A
65 126 17 06C  
-0.9  
<TS 843 A
65 138 26 04C  
-0.13  
<TS 844 A
65 152 20 VS3 0.98  
<TS 845 A
66 13 10 VS4  
-0.86  
<TS 846 A
66 13 10 01C  
-0.88  
<TS 847 A
66 25 12 04H 0.87  
<TS 848 A
66 27 15 06C 0.82  
<TS 849 A
66 31 10 05H  
-0.91  
<TS 850 A
66 31 18 04H 0.93  
<TS 851 A
66 35 13 04H 0.86  
<TS 852 A
66 35 12 03H 0.9  
<TS 853 A
66 37 9
06H  
-0.09  
<TS 854 A
66 39 7
05H 0.92  
<TS 855 A
66 45 10 05H 0.99  
<TS 856 A
66 49 9
05H 1  
<TS 857 A
66 55 12 02H 0.88  
<TS 858 A
66 59 14 06C 0.77  
<TS 38 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 859     A       66       61       12       04H       0.87   <TS 860     A       66       63         7       02H       -0.84   <TS 861     A       66       63         10       06C       0.84   <TS 862     A       66       75       11       05H       0.89   <TS 863     A       66       77       10       06C       0.81   <TS 864     A       66       77         5       DBC       -1.94   <TS 865     A       66       79         8       03H       -0.83   <TS 866     A       66       79       10       01H       -0.17   <TS 867     A       66       83       12       06C       0.86   <TS 868     A       66       89       13       04C       -0.92   <TS 869     A       66       89         9       03C       0.02   <TS 870     A       66       107       15       03H       0.11   <TS 871     A       66       107       14       02C       -0.96   <TS 872     A       66       109       15       03H       -0.79   <TS 873     A       66       109       15       04C       0.92   <TS 874     A       66       109       14       04C       0.11   <TS 875     A       66       109       20       02C       0.87   <TS 876     A       66       111       10       02H       -0.9   <TS 877     A       66       111       13       02H       0.91   <TS 878     A       66       113       17       03H       0.92   <TS 879     A       66       113       15       02C       0.85   <TS 880     A       66       123       10       06C       -0.88   <TS 881     A       66       123         9       03C       0.92   <TS 882     A       66       129         8       DBH       -1.63   <TS 883     A       66       137       12       06C       -0.85   <TS 884     A       66       147       11       03C       -0.2   <TS 885     A       66       153       14       02C       0.88   <TS 886     A       66       153       10       02C       -0.87   <TS 887     A       67       12       11       03H       0.89   <TS 888     A       67       14       25       05H       0.74   <TS 889     A       67       20       16       VS5       0.71   <TS 890     A       67       24       22       06H       0.82   <TS 891     A       67       24       10       06C       0.84   <TS 892     A       67       24         8       06H       0.18   <TS 893     A       67       30       14       06C       -0.97   <TS 894     A       67       32       10       06H       0.88   <TS 895     A       67       34       10       06C       0.75   <TS 896     A       67       38       11       06H       0.92   <TS 897     A       67       38         6       06H       -0.15   <TS 39 of 156
Percent No SG Row Column in Depth Location Elevation TS 859 A
66 61 12 04H 0.87  
<TS 860 A
66 63 7
02H  
-0.84  
<TS 861 A
66 63 10 06C 0.84  
<TS 862 A
66 75 11 05H 0.89  
<TS 863 A
66 77 10 06C 0.81  
<TS 864 A
66 77 5
DBC  
-1.94  
<TS 865 A
66 79 8
03H  
-0.83  
<TS 866 A
66 79 10 01H  
-0.17  
<TS 867 A
66 83 12 06C 0.86  
<TS 868 A
66 89 13 04C  
-0.92  
<TS 869 A
66 89 9
03C 0.02  
<TS 870 A
66 107 15 03H 0.11  
<TS 871 A
66 107 14 02C  
-0.96  
<TS 872 A
66 109 15 03H  
-0.79  
<TS 873 A
66 109 15 04C 0.92  
<TS 874 A
66 109 14 04C 0.11  
<TS 875 A
66 109 20 02C 0.87  
<TS 876 A
66 111 10 02H  
-0.9  
<TS 877 A
66 111 13 02H 0.91  
<TS 878 A
66 113 17 03H 0.92  
<TS 879 A
66 113 15 02C 0.85  
<TS 880 A
66 123 10 06C  
-0.88  
<TS 881 A
66 123 9
03C 0.92  
<TS 882 A
66 129 8
DBH  
-1.63  
<TS 883 A
66 137 12 06C  
-0.85  
<TS 884 A
66 147 11 03C  
-0.2  
<TS 885 A
66 153 14 02C 0.88  
<TS 886 A
66 153 10 02C  
-0.87  
<TS 887 A
67 12 11 03H 0.89  
<TS 888 A
67 14 25 05H 0.74  
<TS 889 A
67 20 16 VS5 0.71  
<TS 890 A
67 24 22 06H 0.82  
<TS 891 A
67 24 10 06C 0.84  
<TS 892 A
67 24 8
06H 0.18  
<TS 893 A
67 30 14 06C  
-0.97  
<TS 894 A
67 32 10 06H 0.88  
<TS 895 A
67 34 10 06C 0.75  
<TS 896 A
67 38 11 06H 0.92  
<TS 897 A
67 38 6
06H  
-0.15  
<TS 39 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 898     A       67       50         13       03C         0.9   <TS 899     A       67       50         9       03C       0.11   <TS 900     A       67       56         11       VS3       0.97   <TS 901     A       67       58         12       04C       0.92   <TS 902     A       67       58         15       03C       0.09   <TS 903     A       67       58         15       02C       0.94   <TS 904     A       67       106         13       03H       0.88   <TS 905     A       67       106         10       02H       0.93   <TS 906     A       67       106         10       05C       0.79   <TS 907     A       67       106         8       03C       0.86   <TS 908     A       67       110         10       04H       -0.84   <TS 909     A       67       110         8       03C       0.88   <TS 910     A       67       112         12       VS3       0.85   <TS 911     A       67       112         12       04C       -0.85   <TS 912     A       67       114         12       03C       -0.92   <TS 913     A       67       114         24       02C       0.92   <TS 914     A       67       118         17       03C       0.92   <TS 915     A       67       120         11       06H       -0.09   <TS 916     A       67       120         11       06H       0.87   <TS 917     A       67       120         15       VS5       0.85   <TS 918     A       67       130         14       DBH         2.1   <TS 919     A       67       136         20       VS3       0.95   <TS 920     A       67       136         13       04C       0.92   <TS 921     A       67       138         14       03C       0.85   <TS 922     A       67       154         15       04C       0.86   <TS 923     A       67       154         17       02C       0.84   <TS 924     A       67       154         18       01C       -0.61   <TS 925     A       68       15         8       05H       -0.2   <TS 926     A       68       17         16       VS3       -0.75   <TS 927     A       68       17         7       VS4       -0.97   <TS 928     A       68       17         13       VS4         0.8   <TS 929     A       68       21         12       VS3       -0.83   <TS 930     A       68       21         22       VS4       -0.9   <TS 931     A       68       21         22       VS4       0.88   <TS 932     A       68       21         18       VS5       0.76   <TS 933     A       68       27         7       VS3       -0.93   <TS 934     A       68       39         6       VS3       0.92   <TS 935     A       68       41         14       04H       0.91   <TS 936     A       68       45         15       06H       0.94   <TS 40 of 156
Percent No SG Row Column in Depth Location Elevation TS 898 A
67 50 13 03C 0.9  
<TS 899 A
67 50 9
03C 0.11  
<TS 900 A
67 56 11 VS3 0.97  
<TS 901 A
67 58 12 04C 0.92  
<TS 902 A
67 58 15 03C 0.09  
<TS 903 A
67 58 15 02C 0.94  
<TS 904 A
67 106 13 03H 0.88  
<TS 905 A
67 106 10 02H 0.93  
<TS 906 A
67 106 10 05C 0.79  
<TS 907 A
67 106 8
03C 0.86  
<TS 908 A
67 110 10 04H  
-0.84  
<TS 909 A
67 110 8
03C 0.88  
<TS 910 A
67 112 12 VS3 0.85  
<TS 911 A
67 112 12 04C  
-0.85  
<TS 912 A
67 114 12 03C  
-0.92  
<TS 913 A
67 114 24 02C 0.92  
<TS 914 A
67 118 17 03C 0.92  
<TS 915 A
67 120 11 06H  
-0.09  
<TS 916 A
67 120 11 06H 0.87  
<TS 917 A
67 120 15 VS5 0.85  
<TS 918 A
67 130 14 DBH 2.1  
<TS 919 A
67 136 20 VS3 0.95  
<TS 920 A
67 136 13 04C 0.92  
<TS 921 A
67 138 14 03C 0.85  
<TS 922 A
67 154 15 04C 0.86  
<TS 923 A
67 154 17 02C 0.84  
<TS 924 A
67 154 18 01C  
-0.61  
<TS 925 A
68 15 8
05H  
-0.2  
<TS 926 A
68 17 16 VS3  
-0.75  
<TS 927 A
68 17 7
VS4  
-0.97  
<TS 928 A
68 17 13 VS4 0.8  
<TS 929 A
68 21 12 VS3  
-0.83  
<TS 930 A
68 21 22 VS4  
-0.9  
<TS 931 A
68 21 22 VS4 0.88  
<TS 932 A
68 21 18 VS5 0.76  
<TS 933 A
68 27 7
VS3  
-0.93  
<TS 934 A
68 39 6
VS3 0.92  
<TS 935 A
68 41 14 04H 0.91  
<TS 936 A
68 45 15 06H 0.94  
<TS 40 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 937     A       68         53       12       04H       -0.22   <TS 938     A       68       61         10       03C       -0.88   <TS 939     A       68       61         12       06H       0.83   <TS 940     A       68       81         19       03H       0.88   <TS 941     A       68       87         10       03C       -0.86   <TS 942     A       68       103       10       02H       -0.9   <TS 943     A       68       105         9       04H       0.07   <TS 944     A       68       107         9       03H       -0.11   <TS 945     A       68       111       12       03H       -0.86   <TS 946     A       68       111       11       04H       -0.85   <TS 947     A       68       139       32       VS3       -0.85   <TS 948     A       68       139       16       VS5       -0.85   <TS 949     A       68       139       38       VS5       0.72   <TS 950     A       68       141       22       DBH       1.77   <TS 951     A       69         22       17       VS3       0.8   <TS 952     A       69         22       26       VS4       -0.93   <TS 953     A       69         22       27       VS4       0.8   <TS 954     A       69         22         9       VS4       -0.24   <TS 955     A       69         22       27       VS5       0.76   <TS 956     A       69         30       13       DBC       1.48   <TS 957     A       69         34       14       DBH       1.92   <TS 958     A       69         34       12       06C       0.84   <TS 959     A       69       40         12       04H       0.89   <TS 960     A       69       40         8       DBH       1.96   <TS 961     A       69         50       11       DBH       1.54   <TS 962     A       69         54       15       03C       -0.87   <TS 963     A       69         56         8       06H       0.88   <TS 964     A       69         56       10       03C       0.86   <TS 965     A       69         58         8       02C       0.86   <TS 966     A       69         60         6       06H       -0.95   <TS 967     A       69       60         12       06H       0.88   <TS 968     A       69         68       12       05C       -0.88   <TS 969     A       69         76       11       04H       -0.89   <TS 970     A       69         76         6       04H       0.33   <TS 971     A       69         80         6       03H       -0.84   <TS 972     A       69         86       15       06C       0.86   <TS 973     A       69       90         10       03C       -0.84   <TS 974     A       69       102         7       04H       0.93   <TS 975     A       69       106       14       VS5       0.83   <TS 41 of 156
Percent No SG Row Column in Depth Location Elevation TS 937 A
68 53 12 04H  
-0.22  
<TS 938 A
68 61 10 03C  
-0.88  
<TS 939 A
68 61 12 06H 0.83  
<TS 940 A
68 81 19 03H 0.88  
<TS 941 A
68 87 10 03C  
-0.86  
<TS 942 A
68 103 10 02H  
-0.9  
<TS 943 A
68 105 9
04H 0.07  
<TS 944 A
68 107 9
03H  
-0.11  
<TS 945 A
68 111 12 03H  
-0.86  
<TS 946 A
68 111 11 04H  
-0.85  
<TS 947 A
68 139 32 VS3  
-0.85  
<TS 948 A
68 139 16 VS5  
-0.85  
<TS 949 A
68 139 38 VS5 0.72  
<TS 950 A
68 141 22 DBH 1.77  
<TS 951 A
69 22 17 VS3 0.8  
<TS 952 A
69 22 26 VS4  
-0.93  
<TS 953 A
69 22 27 VS4 0.8  
<TS 954 A
69 22 9
VS4  
-0.24  
<TS 955 A
69 22 27 VS5 0.76  
<TS 956 A
69 30 13 DBC 1.48  
<TS 957 A
69 34 14 DBH 1.92  
<TS 958 A
69 34 12 06C 0.84  
<TS 959 A
69 40 12 04H 0.89  
<TS 960 A
69 40 8
DBH 1.96  
<TS 961 A
69 50 11 DBH 1.54  
<TS 962 A
69 54 15 03C  
-0.87  
<TS 963 A
69 56 8
06H 0.88  
<TS 964 A
69 56 10 03C 0.86  
<TS 965 A
69 58 8
02C 0.86  
<TS 966 A
69 60 6
06H  
-0.95  
<TS 967 A
69 60 12 06H 0.88  
<TS 968 A
69 68 12 05C  
-0.88  
<TS 969 A
69 76 11 04H  
-0.89  
<TS 970 A
69 76 6
04H 0.33  
<TS 971 A
69 80 6
03H  
-0.84  
<TS 972 A
69 86 15 06C 0.86  
<TS 973 A
69 90 10 03C  
-0.84  
<TS 974 A
69 102 7
04H 0.93  
<TS 975 A
69 106 14 VS5 0.83  
<TS 41 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 976   A       69       106         14       05C       0.9   <TS 977   A       69       108         15     04H       0.86   <TS 978   A       69       110         12     03C       0.94   <TS 979   A       69       112         14     06C       0.88   <TS 980   A       69       112         14       02C       0.94   <TS 981   A       69       116         10     03H       0.11   <TS 982   A       69       122         12     04C       0.85   <TS 983   A       69       126         10     DBC       1.75   <TS 984   A       69       132         15     03C       0.87   <TS 985   A       69       134         19     06C       -0.85   <TS 986   A       69       136         12     VS3       -0.96   <TS 987   A       69       136         13     VS5       0.76   <TS 988   A       69       152         24       VS3       0.94   <TS 989   A       69       152         23       VS3       -0.86   <TS 990   A       70       15         12     VS4       -0.9   <TS 991   A       70       19         10     05H       1.11   <TS 992   A       70       29           6     DBC       1.94   <TS 993   A       70       53         11     04H       0.81   <TS 994   A       70       53           9     05H       -0.17   <TS 995   A       70       53         19     03C       0.11   <TS 996   A       70       53         13     02C       -0.84   <TS 997   A       70       55         21       03C       -0.98   <TS 998   A       70       57           6     DBH       -1.82   <TS 999   A       70       59         11     DBC       1.75   <TS 1000   A       70       61         11     04C       0.86   <TS 1001   A       70       65           8     04C       1.01   <TS 1002   A       70       69         10     05H       -0.17   <TS 1003   A       70       81         10       03H       0.92   <TS 1004   A       70       81         12     VS5       -0.72   <TS 1005   A       70       81         17     DBC       1.77   <TS 1006   A       70       85         13     03H       0.87   <TS 1007   A       70       107         16     04C       -0.85   <TS 1008   A       70       107           9     04H       0.13   <TS 1009   A       70       109         15     03C       0.88   <TS 1010   A       70       115         13     DBH       1.62   <TS 1011   A       70       115         13     03H       0.95   <TS 1012   A       70       119         16     04C       0.85   <TS 1013   A       70       123         13     03C       -0.85   <TS 1014   A       70       129         12     DBC       1.75   <TS 42 of 156
Percent No SG Row Column in Depth Location Elevation TS 976 A
69 106 14 05C 0.9  
<TS 977 A
69 108 15 04H 0.86  
<TS 978 A
69 110 12 03C 0.94  
<TS 979 A
69 112 14 06C 0.88  
<TS 980 A
69 112 14 02C 0.94  
<TS 981 A
69 116 10 03H 0.11  
<TS 982 A
69 122 12 04C 0.85  
<TS 983 A
69 126 10 DBC 1.75  
<TS 984 A
69 132 15 03C 0.87  
<TS 985 A
69 134 19 06C  
-0.85  
<TS 986 A
69 136 12 VS3  
-0.96  
<TS 987 A
69 136 13 VS5 0.76  
<TS 988 A
69 152 24 VS3 0.94  
<TS 989 A
69 152 23 VS3  
-0.86  
<TS 990 A
70 15 12 VS4  
-0.9  
<TS 991 A
70 19 10 05H 1.11  
<TS 992 A
70 29 6
DBC 1.94  
<TS 993 A
70 53 11 04H 0.81  
<TS 994 A
70 53 9
05H  
-0.17  
<TS 995 A
70 53 19 03C 0.11  
<TS 996 A
70 53 13 02C  
-0.84  
<TS 997 A
70 55 21 03C  
-0.98  
<TS 998 A
70 57 6
DBH  
-1.82  
<TS 999 A
70 59 11 DBC 1.75  
<TS 1000 A
70 61 11 04C 0.86  
<TS 1001 A
70 65 8
04C 1.01  
<TS 1002 A
70 69 10 05H  
-0.17  
<TS 1003 A
70 81 10 03H 0.92  
<TS 1004 A
70 81 12 VS5  
-0.72  
<TS 1005 A
70 81 17 DBC 1.77  
<TS 1006 A
70 85 13 03H 0.87  
<TS 1007 A
70 107 16 04C  
-0.85  
<TS 1008 A
70 107 9
04H 0.13  
<TS 1009 A
70 109 15 03C 0.88  
<TS 1010 A
70 115 13 DBH 1.62  
<TS 1011 A
70 115 13 03H 0.95  
<TS 1012 A
70 119 16 04C 0.85  
<TS 1013 A
70 123 13 03C  
-0.85  
<TS 1014 A
70 129 12 DBC 1.75  
<TS 42 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1015   A       70       137         17       06H       0.85   <TS 1016   A       70       143         14       DBH       1.95   <TS 1017   A       70       145         13       DBC       -1.91   <TS 1018   A       70       145         13       VS3       0.81   <TS 1019   A       70       153         24       VS3       -0.91   <TS 1020   A       70       153         15       VS3       0.91   <TS 1021   A       70       153         11       02C       -0.82   <TS 1022   A       70       153         13       DBH       -1.64   <TS 1023   A       71       34         9       03H       -0.84   <TS 1024   A       71       40         9       06C       0.86   <TS 1025   A       71       54         15       03C       0.83   <TS 1026   A       71       54         13       04H       1.04   <TS 1027   A       71       58         13       04C       -0.99   <TS 1028   A       71       78         17       06C       -0.9   <TS 1029   A       71       82         11       03H       0.86   <TS 1030   A       71       90         6       05C         0.9   <TS 1031   A       71       104         11       VS3       0.9   <TS 1032   A       71       108         11       06C       0.86   <TS 1033   A       71       108         12       05C       0.88   <TS 1034   A       71       108         11       04C       0.13   <TS 1035   A       71       108         11       03C       -0.94   <TS 1036   A       71       108         13       02C       -0.15   <TS 1037   A       71       110         12       03H       -0.17   <TS 1038   A       71       110         15       04H       0.81   <TS 1039   A       71       116         10       03C       0.86   <TS 1040   A       71       122         13       03C       0.79   <TS 1041   A       71       126         22       05C       0.88   <TS 1042   A       71       126         8       05C       0.13   <TS 1043   A       71       126         11       VS5       -0.85   <TS 1044   A       71       126         9       VS5       0.83   <TS 1045   A       71       134         18       VS3       -0.77   <TS 1046   A       71       150         14       06H       0.91   <TS 1047   A       72       29         7       DBC       1.98   <TS 1048   A       72       47         9       04C       -0.22   <TS 1049   A       72       53         8       04C       0.91   <TS 1050   A       72       53         13       04C       -0.94   <TS 1051   A       72       53         16       02C       0.86   <TS 1052   A       72       55         13       04C       -0.18   <TS 1053   A       72       55         15       03C       -0.92   <TS 43 of 156
Percent No SG Row Column in Depth Location Elevation TS 1015 A
70 137 17 06H 0.85  
<TS 1016 A
70 143 14 DBH 1.95  
<TS 1017 A
70 145 13 DBC  
-1.91  
<TS 1018 A
70 145 13 VS3 0.81  
<TS 1019 A
70 153 24 VS3  
-0.91  
<TS 1020 A
70 153 15 VS3 0.91  
<TS 1021 A
70 153 11 02C  
-0.82  
<TS 1022 A
70 153 13 DBH  
-1.64  
<TS 1023 A
71 34 9
03H  
-0.84  
<TS 1024 A
71 40 9
06C 0.86  
<TS 1025 A
71 54 15 03C 0.83  
<TS 1026 A
71 54 13 04H 1.04  
<TS 1027 A
71 58 13 04C  
-0.99  
<TS 1028 A
71 78 17 06C  
-0.9  
<TS 1029 A
71 82 11 03H 0.86  
<TS 1030 A
71 90 6
05C 0.9  
<TS 1031 A
71 104 11 VS3 0.9  
<TS 1032 A
71 108 11 06C 0.86  
<TS 1033 A
71 108 12 05C 0.88  
<TS 1034 A
71 108 11 04C 0.13  
<TS 1035 A
71 108 11 03C  
-0.94  
<TS 1036 A
71 108 13 02C  
-0.15  
<TS 1037 A
71 110 12 03H  
-0.17  
<TS 1038 A
71 110 15 04H 0.81  
<TS 1039 A
71 116 10 03C 0.86  
<TS 1040 A
71 122 13 03C 0.79  
<TS 1041 A
71 126 22 05C 0.88  
<TS 1042 A
71 126 8
05C 0.13  
<TS 1043 A
71 126 11 VS5  
-0.85  
<TS 1044 A
71 126 9
VS5 0.83  
<TS 1045 A
71 134 18 VS3  
-0.77  
<TS 1046 A
71 150 14 06H 0.91  
<TS 1047 A
72 29 7
DBC 1.98  
<TS 1048 A
72 47 9
04C  
-0.22  
<TS 1049 A
72 53 8
04C 0.91  
<TS 1050 A
72 53 13 04C  
-0.94  
<TS 1051 A
72 53 16 02C 0.86  
<TS 1052 A
72 55 13 04C  
-0.18  
<TS 1053 A
72 55 15 03C  
-0.92  
<TS 43 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1054   A       72       61       15       04C       -0.88   <TS 1055   A       72       85       10       05C       0.13   <TS 1056   A       72       89       10       02C       0.88   <TS 1057   A       72       109       10       04H       0.15   <TS 1058   A       72       111       10       04H       0.92   <TS 1059   A       72       127       16       VS4       -0.07   <TS 1060   A       72       127       18       04C       0.88   <TS 1061   A       72       131       12       DBH       1.93   <TS 1062   A       72       143       20       DBC       1.99   <TS 1063   A       72       149       17       DBH       1.97   <TS 1064   A       72       151       11       01H       -0.11   <TS 1065   A       73       14       14       05H       -0.98   <TS 1066   A       73       14       18       VS4         -1   <TS 1067   A       73       14       15       VS4       0.89   <TS 1068   A       73       44       20       06C       -0.96   <TS 1069   A       73       44       16       04H       0.91   <TS 1070   A       73       46       10       04H       0.94   <TS 1071   A       73       56       13       05C       -0.9   <TS 1072   A       73       66       17       04C       0.79   <TS 1073   A       73       110       11       03H       -0.86   <TS 1074   A       73       112       12       03C         0.9   <TS 1075   A       73       124       13       06C       0.92   <TS 1076   A       73       134       17       06C       -0.83   <TS 1077   A       73       152       15       VS3       -0.83   <TS 1078   A       73       152       15       VS3       0.98   <TS 1079   A       74       15       19       VS4         1.1   <TS 1080   A       74       15       11       01C       -0.95   <TS 1081   A       74       19       12       DBC       1.43   <TS 1082   A       74       33       12       DBC       1.48   <TS 1083   A       74       59         7       02C         0.9   <TS 1084   A       74       79       13       05C       -0.88   <TS 1085   A       74       121       13       03H       -0.86   <TS 1086   A       74       123         9       04H       -0.84   <TS 1087   A       74       123       11       05C       -0.92   <TS 1088   A       74       123       15       04C       0.94   <TS 1089   A       74       125       14       03H       -0.9   <TS 1090   A       74       127       12       03C         1   <TS 1091   A       74       129       10       VS5       -0.86   <TS 1092   A       74       145       14       DBC         1.8   <TS 44 of 156
Percent No SG Row Column in Depth Location Elevation TS 1054 A
72 61 15 04C  
-0.88  
<TS 1055 A
72 85 10 05C 0.13  
<TS 1056 A
72 89 10 02C 0.88  
<TS 1057 A
72 109 10 04H 0.15  
<TS 1058 A
72 111 10 04H 0.92  
<TS 1059 A
72 127 16 VS4  
-0.07  
<TS 1060 A
72 127 18 04C 0.88  
<TS 1061 A
72 131 12 DBH 1.93  
<TS 1062 A
72 143 20 DBC 1.99  
<TS 1063 A
72 149 17 DBH 1.97  
<TS 1064 A
72 151 11 01H  
-0.11  
<TS 1065 A
73 14 14 05H  
-0.98  
<TS 1066 A
73 14 18 VS4  
-1  
<TS 1067 A
73 14 15 VS4 0.89  
<TS 1068 A
73 44 20 06C  
-0.96  
<TS 1069 A
73 44 16 04H 0.91  
<TS 1070 A
73 46 10 04H 0.94  
<TS 1071 A
73 56 13 05C  
-0.9  
<TS 1072 A
73 66 17 04C 0.79  
<TS 1073 A
73 110 11 03H  
-0.86  
<TS 1074 A
73 112 12 03C 0.9  
<TS 1075 A
73 124 13 06C 0.92  
<TS 1076 A
73 134 17 06C  
-0.83  
<TS 1077 A
73 152 15 VS3  
-0.83  
<TS 1078 A
73 152 15 VS3 0.98  
<TS 1079 A
74 15 19 VS4 1.1  
<TS 1080 A
74 15 11 01C  
-0.95  
<TS 1081 A
74 19 12 DBC 1.43  
<TS 1082 A
74 33 12 DBC 1.48  
<TS 1083 A
74 59 7
02C 0.9  
<TS 1084 A
74 79 13 05C  
-0.88  
<TS 1085 A
74 121 13 03H  
-0.86  
<TS 1086 A
74 123 9
04H  
-0.84  
<TS 1087 A
74 123 11 05C  
-0.92  
<TS 1088 A
74 123 15 04C 0.94  
<TS 1089 A
74 125 14 03H  
-0.9  
<TS 1090 A
74 127 12 03C 1  
<TS 1091 A
74 129 10 VS5  
-0.86  
<TS 1092 A
74 145 14 DBC 1.8  
<TS 44 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1093   A       74       149       11       DBC       1.51   <TS 1094   A       75       16       17       03H       0.43   <TS 1095   A       75       16       29       VS5         -1   <TS 1096   A       75       16       15       06C       0.02   <TS 1097   A       75       20         14       03H       0.87   <TS 1098   A       75       20         14       04H       -0.81   <TS 1099   A       75       28       15       DBH       1.81   <TS 1100   A       75       32       12       DBH       1.76   <TS 1101   A       75       40         12       06C       0.85   <TS 1102   A       75       44         37       VS3       -1.01   <TS 1103   A       75       44         22       VS3       0.99   <TS 1104   A       75       48         10       DBH       -1.59   <TS 1105   A       75       48         14       01C       -0.84   <TS 1106   A       75       50       24       VS3       -0.86   <TS 1107   A       75       50       18       VS3       0.86   <TS 1108   A       75       56       14       03C       0.84   <TS 1109   A       75       58       14       VS3       1.01   <TS 1110   A       75       68       15       02C       0.85   <TS 1111   A       75       76       13       02H         0.9   <TS 1112   A       75       76       12       02H       -0.91   <TS 1113   A       75       82       11       03H       0.89   <TS 1114   A       75       92       11       06H       -0.78   <TS 1115   A       75       104       14       02C       -0.85   <TS 1116   A       75       110       12       DBC       -1.48   <TS 1117   A       75       114       15       VS3       -0.83   <TS 1118   A       75       120       15       03C       0.81   <TS 1119   A       75       126       12       DBH         1.8   <TS 1120   A       75       128       14       VS5         0.9   <TS 1121   A       75       136       15       04C         0.9   <TS 1122   A       75       136         8       04C       -0.11   <TS 1123   A       75       148       12       06C       0.88   <TS 1124   A       75       150       17       02C       0.81   <TS 1125   A       75       150       13       04C       0.84   <TS 1126   A       76       15       34       DBC       -1.76   <TS 1127   A       76       15       11       DBC       1.98   <TS 1128   A       76       15       11       06C       0.85   <TS 1129   A       76       15       12       01C         0.2   <TS 1130   A       76       15       11       03H       -0.2   <TS 1131   A       76       15       10       04H       -0.8   <TS 45 of 156
Percent No SG Row Column in Depth Location Elevation TS 1093 A
74 149 11 DBC 1.51  
<TS 1094 A
75 16 17 03H 0.43  
<TS 1095 A
75 16 29 VS5  
-1  
<TS 1096 A
75 16 15 06C 0.02  
<TS 1097 A
75 20 14 03H 0.87  
<TS 1098 A
75 20 14 04H  
-0.81  
<TS 1099 A
75 28 15 DBH 1.81  
<TS 1100 A
75 32 12 DBH 1.76  
<TS 1101 A
75 40 12 06C 0.85  
<TS 1102 A
75 44 37 VS3  
-1.01  
<TS 1103 A
75 44 22 VS3 0.99  
<TS 1104 A
75 48 10 DBH  
-1.59  
<TS 1105 A
75 48 14 01C  
-0.84  
<TS 1106 A
75 50 24 VS3  
-0.86  
<TS 1107 A
75 50 18 VS3 0.86  
<TS 1108 A
75 56 14 03C 0.84  
<TS 1109 A
75 58 14 VS3 1.01  
<TS 1110 A
75 68 15 02C 0.85  
<TS 1111 A
75 76 13 02H 0.9  
<TS 1112 A
75 76 12 02H  
-0.91  
<TS 1113 A
75 82 11 03H 0.89  
<TS 1114 A
75 92 11 06H  
-0.78  
<TS 1115 A
75 104 14 02C  
-0.85  
<TS 1116 A
75 110 12 DBC  
-1.48  
<TS 1117 A
75 114 15 VS3  
-0.83  
<TS 1118 A
75 120 15 03C 0.81  
<TS 1119 A
75 126 12 DBH 1.8  
<TS 1120 A
75 128 14 VS5 0.9  
<TS 1121 A
75 136 15 04C 0.9  
<TS 1122 A
75 136 8
04C  
-0.11  
<TS 1123 A
75 148 12 06C 0.88  
<TS 1124 A
75 150 17 02C 0.81  
<TS 1125 A
75 150 13 04C 0.84  
<TS 1126 A
76 15 34 DBC  
-1.76  
<TS 1127 A
76 15 11 DBC 1.98  
<TS 1128 A
76 15 11 06C 0.85  
<TS 1129 A
76 15 12 01C 0.2  
<TS 1130 A
76 15 11 03H  
-0.2  
<TS 1131 A
76 15 10 04H  
-0.8  
<TS 45 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1132   A       76       17         14       DBC       1.66   <TS 1133   A       76       19         11       DBC         1.7   <TS 1134   A       76       21         12       03H       0.87   <TS 1135   A       76       21         13       04H       0.84   <TS 1136   A       76       37         9       06H       -0.13   <TS 1137   A       76       51         14       VS4       0.95   <TS 1138   A       76       51         6       VS3       0.95   <TS 1139   A       76       51         8       VS3       -0.9   <TS 1140   A       76       51         11       04C       0.11   <TS 1141   A       76       53         14       03C         0.9   <TS 1142   A       76       55         21       03C         0.9   <TS 1143   A       76       57         11       05C       -0.9   <TS 1144   A       76       57         14       02C       0.79   <TS 1145   A       76       65         10       04C       -0.11   <TS 1146   A       76       69         14       04H       -0.21   <TS 1147   A       76       79         11       03H       0.92   <TS 1148   A       76       91         16       02C       0.83   <TS 1149   A       76       97         8       04C       -0.92   <TS 1150   A       76       97         11       04C         0.9   <TS 1151   A       76       101         15       02H       -0.88   <TS 1152   A       76       101         13       03H       0.88   <TS 1153   A       76       103         10       03H       -0.04   <TS 1154   A       76       107         9       05C       0.92   <TS 1155   A       76       111         14       05C       0.81   <TS 1156   A       76       111         18       04C         0.9   <TS 1157   A       76       131         15       VS4       0.99   <TS 1158   A       76       151         12       VS4       0.89   <TS 1159   A       77       16         29       VS4       -0.97   <TS 1160   A       77       16         14       DBC       1.63   <TS 1161   A       77       18         16       05H       -0.99   <TS 1162   A       77       18         10       07C       -0.02   <TS 1163   A       77       18         12       06H       -0.55   <TS 1164   A       77       20         10       06H       -0.24   <TS 1165   A       77       20         11       DBC       -1.28   <TS 1166   A       77       22         14       06H       0.93   <TS 1167   A       77       22         10       03H         0.9   <TS 1168   A       77       24         16       06H         1   <TS 1169   A       77       24         9       03H         0.9   <TS 1170   A       77       24         9       04H       -0.15   <TS 46 of 156
Percent No SG Row Column in Depth Location Elevation TS 1132 A
76 17 14 DBC 1.66  
<TS 1133 A
76 19 11 DBC 1.7  
<TS 1134 A
76 21 12 03H 0.87  
<TS 1135 A
76 21 13 04H 0.84  
<TS 1136 A
76 37 9
06H  
-0.13  
<TS 1137 A
76 51 14 VS4 0.95  
<TS 1138 A
76 51 6
VS3 0.95  
<TS 1139 A
76 51 8
VS3  
-0.9  
<TS 1140 A
76 51 11 04C 0.11  
<TS 1141 A
76 53 14 03C 0.9  
<TS 1142 A
76 55 21 03C 0.9  
<TS 1143 A
76 57 11 05C  
-0.9  
<TS 1144 A
76 57 14 02C 0.79  
<TS 1145 A
76 65 10 04C  
-0.11  
<TS 1146 A
76 69 14 04H  
-0.21  
<TS 1147 A
76 79 11 03H 0.92  
<TS 1148 A
76 91 16 02C 0.83  
<TS 1149 A
76 97 8
04C  
-0.92  
<TS 1150 A
76 97 11 04C 0.9  
<TS 1151 A
76 101 15 02H  
-0.88  
<TS 1152 A
76 101 13 03H 0.88  
<TS 1153 A
76 103 10 03H  
-0.04  
<TS 1154 A
76 107 9
05C 0.92  
<TS 1155 A
76 111 14 05C 0.81  
<TS 1156 A
76 111 18 04C 0.9  
<TS 1157 A
76 131 15 VS4 0.99  
<TS 1158 A
76 151 12 VS4 0.89  
<TS 1159 A
77 16 29 VS4  
-0.97  
<TS 1160 A
77 16 14 DBC 1.63  
<TS 1161 A
77 18 16 05H  
-0.99  
<TS 1162 A
77 18 10 07C  
-0.02  
<TS 1163 A
77 18 12 06H  
-0.55  
<TS 1164 A
77 20 10 06H  
-0.24  
<TS 1165 A
77 20 11 DBC  
-1.28  
<TS 1166 A
77 22 14 06H 0.93  
<TS 1167 A
77 22 10 03H 0.9  
<TS 1168 A
77 24 16 06H 1  
<TS 1169 A
77 24 9
03H 0.9  
<TS 1170 A
77 24 9
04H  
-0.15  
<TS 46 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1171   A       77       28         9       06H       0.93   <TS 1172   A       77       44       23       VS5       0.97   <TS 1173   A       77       44         12       VS4       0.15   <TS 1174   A       77       44         13       VS4       -0.22   <TS 1175   A       77       44         19       VS3       0.79   <TS 1176   A       77       50       13       07C         0.4   <TS 1177   A       77       52       12       02C       1.01   <TS 1178   A       77       52         9       03C       -0.87   <TS 1179   A       77       52       10       06C       -0.86   <TS 1180   A       77       62       16       03C       0.88   <TS 1181   A       77       68       12       02H       0.92   <TS 1182   A       77       76       10       VS5       0.95   <TS 1183   A       77       82       14       05C         0.9   <TS 1184   A       77       92       15       02C       -0.92   <TS 1185   A       77       98         7       03H       -0.06   <TS 1186   A       77       98         6       03H       -0.91   <TS 1187   A       77       102       12       03H       0.89   <TS 1188   A       77       116       10       04H       -0.92   <TS 1189   A       77       122       18       06C       0.79   <TS 1190   A       77       124       16       03C       0.88   <TS 1191   A       77       124       12       03C       -0.9   <TS 1192   A       77       126       14       06H         0.9   <TS 1193   A       77       138       17       07C       -1.23   <TS 1194   A       77       144       10       04C       0.81   <TS 1195   A       77       148       24       03C       0.81   <TS 1196   A       77       148       16       07H       -0.99   <TS 1197   A       77       150       17       02C       0.88   <TS 1198   A       78       17       15       DBH       -1.57   <TS 1199   A       78       19       11       DBC       -1.78   <TS 1200   A       78       25         13       05C       -0.9   <TS 1201   A       78       25       11       DBC       -1.62   <TS 1202   A       78       75       13       02H       0.19   <TS 1203   A       78       87       12       01C       0.81   <TS 1204   A       78       101       14       03H         0.9   <TS 1205   A       78       105       14       VS3       0.83   <TS 1206   A       78       105       12       02H       -0.88   <TS 1207   A       78       109         9       04H       -0.09   <TS 1208   A       78       113       21       02C       0.85   <TS 1209   A       78       119       14       03H       0.88   <TS 47 of 156
Percent No SG Row Column in Depth Location Elevation TS 1171 A
77 28 9
06H 0.93  
<TS 1172 A
77 44 23 VS5 0.97  
<TS 1173 A
77 44 12 VS4 0.15  
<TS 1174 A
77 44 13 VS4  
-0.22  
<TS 1175 A
77 44 19 VS3 0.79  
<TS 1176 A
77 50 13 07C 0.4  
<TS 1177 A
77 52 12 02C 1.01  
<TS 1178 A
77 52 9
03C  
-0.87  
<TS 1179 A
77 52 10 06C  
-0.86  
<TS 1180 A
77 62 16 03C 0.88  
<TS 1181 A
77 68 12 02H 0.92  
<TS 1182 A
77 76 10 VS5 0.95  
<TS 1183 A
77 82 14 05C 0.9  
<TS 1184 A
77 92 15 02C  
-0.92  
<TS 1185 A
77 98 7
03H  
-0.06  
<TS 1186 A
77 98 6
03H  
-0.91  
<TS 1187 A
77 102 12 03H 0.89  
<TS 1188 A
77 116 10 04H  
-0.92  
<TS 1189 A
77 122 18 06C 0.79  
<TS 1190 A
77 124 16 03C 0.88  
<TS 1191 A
77 124 12 03C  
-0.9  
<TS 1192 A
77 126 14 06H 0.9  
<TS 1193 A
77 138 17 07C  
-1.23  
<TS 1194 A
77 144 10 04C 0.81  
<TS 1195 A
77 148 24 03C 0.81  
<TS 1196 A
77 148 16 07H  
-0.99  
<TS 1197 A
77 150 17 02C 0.88  
<TS 1198 A
78 17 15 DBH  
-1.57  
<TS 1199 A
78 19 11 DBC  
-1.78  
<TS 1200 A
78 25 13 05C  
-0.9  
<TS 1201 A
78 25 11 DBC  
-1.62  
<TS 1202 A
78 75 13 02H 0.19  
<TS 1203 A
78 87 12 01C 0.81  
<TS 1204 A
78 101 14 03H 0.9  
<TS 1205 A
78 105 14 VS3 0.83  
<TS 1206 A
78 105 12 02H  
-0.88  
<TS 1207 A
78 109 9
04H  
-0.09  
<TS 1208 A
78 113 21 02C 0.85  
<TS 1209 A
78 119 14 03H 0.88  
<TS 47 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1210   A       78       119         13       02C       0.91   <TS 1211   A       78       127         11       03C       0.85   <TS 1212   A       78       147         15       02C       -0.18   <TS 1213   A       78       149         11       DBC       -1.66   <TS 1214   A       79       18         17       VS4       -0.97   <TS 1215   A       79       18         10     VS4       0.99   <TS 1216   A       79       18         13       DBC         1.7   <TS 1217   A       79       20         12       05H       0.87   <TS 1218   A       79       22         11     07C       0.93   <TS 1219   A       79       30         10     DBH       -1.7   <TS 1220   A       79       48         13     04C       -0.18   <TS 1221   A       79       68         14       07H       0.92   <TS 1222   A       79       68         13     04C       -0.9   <TS 1223   A       79       72         15     04H       0.87   <TS 1224   A       79       72         17     VS3       -0.09   <TS 1225   A       79       72         6       05H       -0.87   <TS 1226   A       79       74         11     05C       -0.9   <TS 1227   A       79       78         10     05C       0.84   <TS 1228   A       79       82         15     03H       0.86   <TS 1229   A       79       82         8       05C       0.88   <TS 1230   A       79       86         11     01C       0.86   <TS 1231   A       79       90         15     04C       -0.13   <TS 1232   A       79       94         12     03C       -0.92   <TS 1233   A       79       100         8       02H       0.86   <TS 1234   A       79       100         13     03H       0.88   <TS 1235   A       79       100         9       05H       0.87   <TS 1236   A       79       104         13       05H       0.91   <TS 1237   A       79       104         7       05H       -0.04   <TS 1238   A       79       114         11     02H       -0.8   <TS 1239   A       79       114         10       05C       -0.87   <TS 1240   A       79       116         11       03H       -0.86   <TS 1241   A       79       116         15     03C       -0.92   <TS 1242   A       79       120         11     04H       0.82   <TS 1243   A       79       128         22       04C         0.9   <TS 1244   A       79       144         15     VS5       -0.86   <TS 1245   A       79       144         24       VS5       0.89   <TS 1246   A       79       148         12     02C       0.86   <TS 1247   A       79       150         21       VS4       0.87   <TS 1248   A       79       150         14     02C         0.9   <TS 48 of 156
Percent No SG Row Column in Depth Location Elevation TS 1210 A
78 119 13 02C 0.91  
<TS 1211 A
78 127 11 03C 0.85  
<TS 1212 A
78 147 15 02C  
-0.18  
<TS 1213 A
78 149 11 DBC  
-1.66  
<TS 1214 A
79 18 17 VS4  
-0.97  
<TS 1215 A
79 18 10 VS4 0.99  
<TS 1216 A
79 18 13 DBC 1.7  
<TS 1217 A
79 20 12 05H 0.87  
<TS 1218 A
79 22 11 07C 0.93  
<TS 1219 A
79 30 10 DBH  
-1.7  
<TS 1220 A
79 48 13 04C  
-0.18  
<TS 1221 A
79 68 14 07H 0.92  
<TS 1222 A
79 68 13 04C  
-0.9  
<TS 1223 A
79 72 15 04H 0.87  
<TS 1224 A
79 72 17 VS3  
-0.09  
<TS 1225 A
79 72 6
05H  
-0.87  
<TS 1226 A
79 74 11 05C  
-0.9  
<TS 1227 A
79 78 10 05C 0.84  
<TS 1228 A
79 82 15 03H 0.86  
<TS 1229 A
79 82 8
05C 0.88  
<TS 1230 A
79 86 11 01C 0.86  
<TS 1231 A
79 90 15 04C  
-0.13  
<TS 1232 A
79 94 12 03C  
-0.92  
<TS 1233 A
79 100 8
02H 0.86  
<TS 1234 A
79 100 13 03H 0.88  
<TS 1235 A
79 100 9
05H 0.87  
<TS 1236 A
79 104 13 05H 0.91  
<TS 1237 A
79 104 7
05H  
-0.04  
<TS 1238 A
79 114 11 02H  
-0.8  
<TS 1239 A
79 114 10 05C  
-0.87  
<TS 1240 A
79 116 11 03H  
-0.86  
<TS 1241 A
79 116 15 03C  
-0.92  
<TS 1242 A
79 120 11 04H 0.82  
<TS 1243 A
79 128 22 04C 0.9  
<TS 1244 A
79 144 15 VS5  
-0.86  
<TS 1245 A
79 144 24 VS5 0.89  
<TS 1246 A
79 148 12 02C 0.86  
<TS 1247 A
79 150 21 VS4 0.87  
<TS 1248 A
79 150 14 02C 0.9  
<TS 48 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1249   A       79       150       17       02C       0.09   <TS 1250   A       80       17       10       VS4       0.62   <TS 1251   A       80       27         13       VS3       0.95   <TS 1252   A       80       57       11       04H       0.11   <TS 1253   A       80       57       16       04H       0.93   <TS 1254   A       80       59         9       04C       0.83   <TS 1255   A       80       65       12       04C       0.81   <TS 1256   A       80       71       10       04H       -0.8   <TS 1257   A       80       77       18       04H       0.84   <TS 1258   A       80       77       10       02H       -0.91   <TS 1259   A       80       77       11       02H       0.89   <TS 1260   A       80       99       10       07C         0.9   <TS 1261   A       80       107       18       DBH       1.73   <TS 1262   A       80       119       10       03C       0.79   <TS 1263   A       80       125       13       05H       0.15   <TS 1264   A       80       133         9       04H       -0.9   <TS 1265   A       80       133       11       04H       0.88   <TS 1266   A       80       143       13       05C       0.85   <TS 1267   A       80       145       10       02C       -0.2   <TS 1268   A       80       147       17       07H       0.81   <TS 1269   A       80       149       18       VS4       -0.85   <TS 1270   A       81       18       12       01H       0.95   <TS 1271   A       81       18       12       VS4       -0.73   <TS 1272   A       81       18         9       DBC       -1.9   <TS 1273   A       81       20       11       04H       0.87   <TS 1274   A       81       20         9       04H       -0.21   <TS 1275   A       81       22         9       DBC       -1.32   <TS 1276   A       81       24         10       DBC       -1.06   <TS 1277   A       81       46         15       VS3       0.02   <TS 1278   A       81       46         14       VS3       0.88   <TS 1279   A       81       46         11       VS4       -0.88   <TS 1280   A       81       46         20       VS5       0.88   <TS 1281   A       81       54       14       05C       -0.9   <TS 1282   A       81       56         9       05C       -0.92   <TS 1283   A       81       70       13       VS4       -0.77   <TS 1284   A       81       84       28       VS4       0.86   <TS 1285   A       81       84       19       07C       -0.11   <TS 1286   A       81       84       12       05C       -0.9   <TS 1287   A       81       84       11       04C       -0.88   <TS 49 of 156
Percent No SG Row Column in Depth Location Elevation TS 1249 A
79 150 17 02C 0.09  
<TS 1250 A
80 17 10 VS4 0.62  
<TS 1251 A
80 27 13 VS3 0.95  
<TS 1252 A
80 57 11 04H 0.11  
<TS 1253 A
80 57 16 04H 0.93  
<TS 1254 A
80 59 9
04C 0.83  
<TS 1255 A
80 65 12 04C 0.81  
<TS 1256 A
80 71 10 04H  
-0.8  
<TS 1257 A
80 77 18 04H 0.84  
<TS 1258 A
80 77 10 02H  
-0.91  
<TS 1259 A
80 77 11 02H 0.89  
<TS 1260 A
80 99 10 07C 0.9  
<TS 1261 A
80 107 18 DBH 1.73  
<TS 1262 A
80 119 10 03C 0.79  
<TS 1263 A
80 125 13 05H 0.15  
<TS 1264 A
80 133 9
04H  
-0.9  
<TS 1265 A
80 133 11 04H 0.88  
<TS 1266 A
80 143 13 05C 0.85  
<TS 1267 A
80 145 10 02C  
-0.2  
<TS 1268 A
80 147 17 07H 0.81  
<TS 1269 A
80 149 18 VS4  
-0.85  
<TS 1270 A
81 18 12 01H 0.95  
<TS 1271 A
81 18 12 VS4  
-0.73  
<TS 1272 A
81 18 9
DBC  
-1.9  
<TS 1273 A
81 20 11 04H 0.87  
<TS 1274 A
81 20 9
04H  
-0.21  
<TS 1275 A
81 22 9
DBC  
-1.32  
<TS 1276 A
81 24 10 DBC  
-1.06  
<TS 1277 A
81 46 15 VS3 0.02  
<TS 1278 A
81 46 14 VS3 0.88  
<TS 1279 A
81 46 11 VS4  
-0.88  
<TS 1280 A
81 46 20 VS5 0.88  
<TS 1281 A
81 54 14 05C  
-0.9  
<TS 1282 A
81 56 9
05C  
-0.92  
<TS 1283 A
81 70 13 VS4  
-0.77  
<TS 1284 A
81 84 28 VS4 0.86  
<TS 1285 A
81 84 19 07C  
-0.11  
<TS 1286 A
81 84 12 05C  
-0.9  
<TS 1287 A
81 84 11 04C  
-0.88  
<TS 49 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1288   A       81       94       11       DBH       1.86   <TS 1289   A       81       94       11       02C       -0.9   <TS 1290   A       81       94         8       02C       -0.2   <TS 1291   A       81       94         10       VS4       0.88   <TS 1292   A       81       100       11       05H       0.89   <TS 1293   A       81       102         9       07C       -0.13   <TS 1294   A       81       102       13       07C       -0.9   <TS 1295   A       81       106       13       05C       0.86   <TS 1296   A       81       118         9       VS3       -0.99   <TS 1297   A       81       118       11       04C       -0.92   <TS 1298   A       81       118         9       03C       -0.83   <TS 1299   A       81       118         6       04C       0.96   <TS 1300   A       81       118       10       03C       0.79   <TS 1301   A       81       130       20       VS3       -0.72   <TS 1302   A       81       130       18       VS3       -0.13   <TS 1303   A       81       148       20       02C         0.8   <TS 1304   A       81       148       21       05C       0.07   <TS 1305   A       82       19         7       VS4       -0.97   <TS 1306   A       82       19       12       VS4       0.62   <TS 1307   A       82       33         17       VS3         0.9   <TS 1308   A       82       35         7       VS3       0.22   <TS 1309   A       82       61         12       VS3       -0.83   <TS 1310   A       82       71         10       VS3         0.9   <TS 1311   A       82       79         14       07C       0.79   <TS 1312   A       82       83         13       03C       -0.92   <TS 1313   A       82       89         18       05C         0.9   <TS 1314   A       82       91         11       07C       0.84   <TS 1315   A       82       101       10       DBH       -1.99   <TS 1316   A       82       101         9       05H       -0.11   <TS 1317   A       82       107       14       04H       0.87   <TS 1318   A       82       121       12       05H       0.91   <TS 1319   A       82       121         9       07C         0.9   <TS 1320   A       82       123       11       03C       -0.87   <TS 1321   A       82       135       17       VS3       -0.92   <TS 1322   A       82       141       19       VS3       -0.79   <TS 1323   A       83       50         13       05C       0.86   <TS 1324   A       83       54         12       07C       -0.9   <TS 1325   A       83       74         12       05H       0.91   <TS 1326   A       83       76         16       02H       0.96   <TS 50 of 156
Percent No SG Row Column in Depth Location Elevation TS 1288 A
81 94 11 DBH 1.86  
<TS 1289 A
81 94 11 02C  
-0.9  
<TS 1290 A
81 94 8
02C  
-0.2  
<TS 1291 A
81 94 10 VS4 0.88  
<TS 1292 A
81 100 11 05H 0.89  
<TS 1293 A
81 102 9
07C  
-0.13  
<TS 1294 A
81 102 13 07C  
-0.9  
<TS 1295 A
81 106 13 05C 0.86  
<TS 1296 A
81 118 9
VS3  
-0.99  
<TS 1297 A
81 118 11 04C  
-0.92  
<TS 1298 A
81 118 9
03C  
-0.83  
<TS 1299 A
81 118 6
04C 0.96  
<TS 1300 A
81 118 10 03C 0.79  
<TS 1301 A
81 130 20 VS3  
-0.72  
<TS 1302 A
81 130 18 VS3  
-0.13  
<TS 1303 A
81 148 20 02C 0.8  
<TS 1304 A
81 148 21 05C 0.07  
<TS 1305 A
82 19 7
VS4  
-0.97  
<TS 1306 A
82 19 12 VS4 0.62  
<TS 1307 A
82 33 17 VS3 0.9  
<TS 1308 A
82 35 7
VS3 0.22  
<TS 1309 A
82 61 12 VS3  
-0.83  
<TS 1310 A
82 71 10 VS3 0.9  
<TS 1311 A
82 79 14 07C 0.79  
<TS 1312 A
82 83 13 03C  
-0.92  
<TS 1313 A
82 89 18 05C 0.9  
<TS 1314 A
82 91 11 07C 0.84  
<TS 1315 A
82 101 10 DBH  
-1.99  
<TS 1316 A
82 101 9
05H  
-0.11  
<TS 1317 A
82 107 14 04H 0.87  
<TS 1318 A
82 121 12 05H 0.91  
<TS 1319 A
82 121 9
07C 0.9  
<TS 1320 A
82 123 11 03C  
-0.87  
<TS 1321 A
82 135 17 VS3  
-0.92  
<TS 1322 A
82 141 19 VS3  
-0.79  
<TS 1323 A
83 50 13 05C 0.86  
<TS 1324 A
83 54 12 07C  
-0.9  
<TS 1325 A
83 74 12 05H 0.91  
<TS 1326 A
83 76 16 02H 0.96  
<TS 50 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1327   A       83       84         10       04H       -0.8   <TS 1328   A       83       84         11       05H       0.93   <TS 1329   A       83       84         13       02C       0.83   <TS 1330   A       83       86         13       04H       0.89   <TS 1331   A       83       88         18       04C         0.9   <TS 1332   A       83       88         8       04C       -0.83   <TS 1333   A       83       90         17       07H       0.92   <TS 1334   A       83       90         10       05H       -0.13   <TS 1335   A       83       100         7       03H       -0.9   <TS 1336   A       83       100         17       04H       0.88   <TS 1337   A       83       100         9       05H       0.91   <TS 1338   A       83       102         13       05C       -0.87   <TS 1339   A       83       102         15       05C       -0.15   <TS 1340   A       83       108         10       04H       1.07   <TS 1341   A       83       112         16     02C       -0.15   <TS 1342   A       83       114         16       VS2       -0.79   <TS 1343   A       83       116         11       VS2       -0.24   <TS 1344   A       83       116         10       VS2       0.92   <TS 1345   A       83       118         13     03H       0.94   <TS 1346   A       83       120         9       04C       0.81   <TS 1347   A       83       122         18       VS2       0.83   <TS 1348   A       83       128         11       DBH       1.73   <TS 1349   A       83       136         11       DBH       1.58   <TS 1350   A       83       146         15       04C       -0.87   <TS 1351   A       83       148         15       VS4       -1.14   <TS 1352   A       83       148         15       VS4       -0.74   <TS 1353   A       83       148         14       07C       0.81   <TS 1354   A       83       148         20       03C       -0.9   <TS 1355   A       84       19         18       01H       -0.45   <TS 1356   A       84       19         12       VS3       0.31   <TS 1357   A       84       19         24       VS4       -0.95   <TS 1358   A       84       19         23       VS4       0.73   <TS 1359   A       84       19         18       VS5       0.95   <TS 1360   A       84       19         16       VS2       0.71   <TS 1361   A       84       25         9       VS2       0.64   <TS 1362   A       84       29         16       VS2       0.69   <TS 1363   A       84       29         12       05C       -0.97   <TS 1364   A       84       33         19       VS2       -0.82   <TS 1365   A       84       37         18     VS2       -0.8   <TS 51 of 156
Percent No SG Row Column in Depth Location Elevation TS 1327 A
83 84 10 04H  
-0.8  
<TS 1328 A
83 84 11 05H 0.93  
<TS 1329 A
83 84 13 02C 0.83  
<TS 1330 A
83 86 13 04H 0.89  
<TS 1331 A
83 88 18 04C 0.9  
<TS 1332 A
83 88 8
04C  
-0.83  
<TS 1333 A
83 90 17 07H 0.92  
<TS 1334 A
83 90 10 05H  
-0.13  
<TS 1335 A
83 100 7
03H  
-0.9  
<TS 1336 A
83 100 17 04H 0.88  
<TS 1337 A
83 100 9
05H 0.91  
<TS 1338 A
83 102 13 05C  
-0.87  
<TS 1339 A
83 102 15 05C  
-0.15  
<TS 1340 A
83 108 10 04H 1.07  
<TS 1341 A
83 112 16 02C  
-0.15  
<TS 1342 A
83 114 16 VS2  
-0.79  
<TS 1343 A
83 116 11 VS2  
-0.24  
<TS 1344 A
83 116 10 VS2 0.92  
<TS 1345 A
83 118 13 03H 0.94  
<TS 1346 A
83 120 9
04C 0.81  
<TS 1347 A
83 122 18 VS2 0.83  
<TS 1348 A
83 128 11 DBH 1.73  
<TS 1349 A
83 136 11 DBH 1.58  
<TS 1350 A
83 146 15 04C  
-0.87  
<TS 1351 A
83 148 15 VS4  
-1.14  
<TS 1352 A
83 148 15 VS4  
-0.74  
<TS 1353 A
83 148 14 07C 0.81  
<TS 1354 A
83 148 20 03C  
-0.9  
<TS 1355 A
84 19 18 01H  
-0.45  
<TS 1356 A
84 19 12 VS3 0.31  
<TS 1357 A
84 19 24 VS4  
-0.95  
<TS 1358 A
84 19 23 VS4 0.73  
<TS 1359 A
84 19 18 VS5 0.95  
<TS 1360 A
84 19 16 VS2 0.71  
<TS 1361 A
84 25 9
VS2 0.64  
<TS 1362 A
84 29 16 VS2 0.69  
<TS 1363 A
84 29 12 05C  
-0.97  
<TS 1364 A
84 33 19 VS2  
-0.82  
<TS 1365 A
84 37 18 VS2  
-0.8  
<TS 51 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1366   A       84       39         10       VS2       -0.81   <TS 1367   A       84       39         18       VS3       -0.77   <TS 1368   A       84       41         13       07H       0.84   <TS 1369   A       84       45         13       VS6       -0.81   <TS 1370   A       84       47         10       06H       0.88   <TS 1371   A       84       51         11       VS2       0.62   <TS 1372   A       84       51         12       VS5         0.9   <TS 1373   A       84       53         24       VS2       -0.73   <TS 1374   A       84       61         11       03C       0.13   <TS 1375   A       84       61         29       03C       0.94   <TS 1376   A       84       73         14       05C       0.88   <TS 1377   A       84       73         7       05C       0.11   <TS 1378   A       84       73         11       04H       0.86   <TS 1379   A       84       73         9       02H       0.13   <TS 1380   A       84       75         9       06C       -0.9   <TS 1381   A       84       81         10       04H       0.87   <TS 1382   A       84       85         11       02H       0.89   <TS 1383   A       84       85         10       02H       -0.86   <TS 1384   A       84       85         11       04H       -0.87   <TS 1385   A       84       85         18       04H       0.87   <TS 1386   A       84       93         12       05C       -0.92   <TS 1387   A       84       93         11       04C       -0.88   <TS 1388   A       84       97         8       05H       0.22   <TS 1389   A       84       99         16       VS2       -0.88   <TS 1390   A       84       119         10       04C       0.98   <TS 1391   A       84       125         13       04C       -0.94   <TS 1392   A       84       141         23       04C       0.85   <TS 1393   A       84       143         13       03C       0.87   <TS 1394   A       84       147         25       VS3       0.77   <TS 1395   A       84       147         14       VS5       0.92   <TS 1396   A       85       20         25       VS4       -0.93   <TS 1397   A       85       20         23       VS4       0.62   <TS 1398   A       85       26         19       03H         0.8   <TS 1399   A       85       28         10       VS3       -0.78   <TS 1400   A       85       30         12       VS3       -0.89   <TS 1401   A       85       32         12       03C       -0.95   <TS 1402   A       85       32         14       VS5       0.84   <TS 1403   A       85       40         7       VS5       -0.99   <TS 1404   A       85       62         20       04C         0.5   <TS 52 of 156
Percent No SG Row Column in Depth Location Elevation TS 1366 A
84 39 10 VS2  
-0.81  
<TS 1367 A
84 39 18 VS3  
-0.77  
<TS 1368 A
84 41 13 07H 0.84  
<TS 1369 A
84 45 13 VS6  
-0.81  
<TS 1370 A
84 47 10 06H 0.88  
<TS 1371 A
84 51 11 VS2 0.62  
<TS 1372 A
84 51 12 VS5 0.9  
<TS 1373 A
84 53 24 VS2  
-0.73  
<TS 1374 A
84 61 11 03C 0.13  
<TS 1375 A
84 61 29 03C 0.94  
<TS 1376 A
84 73 14 05C 0.88  
<TS 1377 A
84 73 7
05C 0.11  
<TS 1378 A
84 73 11 04H 0.86  
<TS 1379 A
84 73 9
02H 0.13  
<TS 1380 A
84 75 9
06C  
-0.9  
<TS 1381 A
84 81 10 04H 0.87  
<TS 1382 A
84 85 11 02H 0.89  
<TS 1383 A
84 85 10 02H  
-0.86  
<TS 1384 A
84 85 11 04H  
-0.87  
<TS 1385 A
84 85 18 04H 0.87  
<TS 1386 A
84 93 12 05C  
-0.92  
<TS 1387 A
84 93 11 04C  
-0.88  
<TS 1388 A
84 97 8
05H 0.22  
<TS 1389 A
84 99 16 VS2  
-0.88  
<TS 1390 A
84 119 10 04C 0.98  
<TS 1391 A
84 125 13 04C  
-0.94  
<TS 1392 A
84 141 23 04C 0.85  
<TS 1393 A
84 143 13 03C 0.87  
<TS 1394 A
84 147 25 VS3 0.77  
<TS 1395 A
84 147 14 VS5 0.92  
<TS 1396 A
85 20 25 VS4  
-0.93  
<TS 1397 A
85 20 23 VS4 0.62  
<TS 1398 A
85 26 19 03H 0.8  
<TS 1399 A
85 28 10 VS3  
-0.78  
<TS 1400 A
85 30 12 VS3  
-0.89  
<TS 1401 A
85 32 12 03C  
-0.95  
<TS 1402 A
85 32 14 VS5 0.84  
<TS 1403 A
85 40 7
VS5  
-0.99  
<TS 1404 A
85 62 20 04C 0.5  
<TS 52 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1405   A       85       84       12       05H       0.85   <TS 1406   A       85       92       16       02C       0.88   <TS 1407   A       85       94       10       02C       0.09   <TS 1408   A       85       104       13       03C       0.92   <TS 1409   A       85       116       16       03C       0.39   <TS 1410   A       85       124       11       03C         0.9   <TS 1411   A       85       130       12       04C       -0.94   <TS 1412   A       85       146       17       02C       0.79   <TS 1413   A       85       146       22       03C       -0.94   <TS 1414   A       86       21       14       VS4       -0.93   <TS 1415   A       86       35       13       VS6       -0.75   <TS 1416   A       86       35       13       VS6       -0.73   <TS 1417   A       86       51       10       VS2       0.88   <TS 1418   A       86       55       16       06C         0.9   <TS 1419   A       86       57         8       05C       0.88   <TS 1420   A       86       59       11       03C       0.87   <TS 1421   A       86       59         8       02C       0.92   <TS 1422   A       86       63       13       06C         0.9   <TS 1423   A       86       65       12       05H       0.89   <TS 1424   A       86       67         10       04C       -0.89   <TS 1425   A       86       67         8       02C         0.9   <TS 1426   A       86       69       10       06C       -0.9   <TS 1427   A       86       81         8       02H       -0.84   <TS 1428   A       86       85         7       05H       -0.13   <TS 1429   A       86       97       16       03H       0.88   <TS 1430   A       86       99       12       VS6       -0.35   <TS 1431   A       86       101       11       05C       -0.87   <TS 1432   A       86       101       15       04H       -0.92   <TS 1433   A       86       107       13       04H       0.85   <TS 1434   A       86       111       10       03H       -0.9   <TS 1435   A       86       111       12       04H       0.02   <TS 1436   A       86       111       17       05C       0.85   <TS 1437   A       86       115       12       02C       -0.99   <TS 1438   A       86       117       10       03H       0.85   <TS 1439   A       86       117       13       06C       0.89   <TS 1440   A       86       143       15       03C       -0.87   <TS 1441   A       86       145       13       03C       -0.87   <TS 1442   A       86       145         8       03C       0.92   <TS 1443   A       86       145       17       04C       0.86   <TS 53 of 156
Percent No SG Row Column in Depth Location Elevation TS 1405 A
85 84 12 05H 0.85  
<TS 1406 A
85 92 16 02C 0.88  
<TS 1407 A
85 94 10 02C 0.09  
<TS 1408 A
85 104 13 03C 0.92  
<TS 1409 A
85 116 16 03C 0.39  
<TS 1410 A
85 124 11 03C 0.9  
<TS 1411 A
85 130 12 04C  
-0.94  
<TS 1412 A
85 146 17 02C 0.79  
<TS 1413 A
85 146 22 03C  
-0.94  
<TS 1414 A
86 21 14 VS4  
-0.93  
<TS 1415 A
86 35 13 VS6  
-0.75  
<TS 1416 A
86 35 13 VS6  
-0.73  
<TS 1417 A
86 51 10 VS2 0.88  
<TS 1418 A
86 55 16 06C 0.9  
<TS 1419 A
86 57 8
05C 0.88  
<TS 1420 A
86 59 11 03C 0.87  
<TS 1421 A
86 59 8
02C 0.92  
<TS 1422 A
86 63 13 06C 0.9  
<TS 1423 A
86 65 12 05H 0.89  
<TS 1424 A
86 67 10 04C  
-0.89  
<TS 1425 A
86 67 8
02C 0.9  
<TS 1426 A
86 69 10 06C  
-0.9  
<TS 1427 A
86 81 8
02H  
-0.84  
<TS 1428 A
86 85 7
05H  
-0.13  
<TS 1429 A
86 97 16 03H 0.88  
<TS 1430 A
86 99 12 VS6  
-0.35  
<TS 1431 A
86 101 11 05C  
-0.87  
<TS 1432 A
86 101 15 04H  
-0.92  
<TS 1433 A
86 107 13 04H 0.85  
<TS 1434 A
86 111 10 03H  
-0.9  
<TS 1435 A
86 111 12 04H 0.02  
<TS 1436 A
86 111 17 05C 0.85  
<TS 1437 A
86 115 12 02C  
-0.99  
<TS 1438 A
86 117 10 03H 0.85  
<TS 1439 A
86 117 13 06C 0.89  
<TS 1440 A
86 143 15 03C  
-0.87  
<TS 1441 A
86 145 13 03C  
-0.87  
<TS 1442 A
86 145 8
03C 0.92  
<TS 1443 A
86 145 17 04C 0.86  
<TS 53 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1444   A       86       145         10       02C       0.65   <TS 1445   A       87       20         15       VS4       -0.22   <TS 1446   A       87       20         23       VS4       0.64   <TS 1447   A       87       20         12       VS4       -0.91   <TS 1448   A       87       22         11       01H         0.9   <TS 1449   A       87       22         12       04H       0.83   <TS 1450   A       87       22         18       VS4       -0.93   <TS 1451   A       87       36         9       07C       0.82   <TS 1452   A       87       36         11       DBH       1.99   <TS 1453   A       87       40         16       07H       -0.95   <TS 1454   A       87       40         7       07H       -0.22   <TS 1455   A       87       40         9       VS2       -0.93   <TS 1456   A       87       40         16       07C       0.79   <TS 1457   A       87       40         8       VS4         0.6   <TS 1458   A       87       56         11       05H       0.91   <TS 1459   A       87       56         14       04C       0.92   <TS 1460   A       87       58         15       VS2       -0.9   <TS 1461   A       87       60         17       VS2       -0.84   <TS 1462   A       87       60         10       03C       0.88   <TS 1463   A       87       60         12       02C       0.84   <TS 1464   A       87       82         13       05H       0.95   <TS 1465   A       87       82         8       05C         0.9   <TS 1466   A       87       88         9       04H       0.31   <TS 1467   A       87       90         9       02C       -0.2   <TS 1468   A       87       90         10       04H       0.93   <TS 1469   A       87       92         10       02C       0.88   <TS 1470   A       87       92         18       04C       0.83   <TS 1471   A       87       92         15       05C       0.85   <TS 1472   A       87       92         10       04H       0.95   <TS 1473   A       87       92         11       04H       -0.74   <TS 1474   A       87       100         13       04H       0.84   <TS 1475   A       87       100         9       05C       -0.88   <TS 1476   A       87       102         20       05H       0.88   <TS 1477   A       87       102         10       04H       -0.09   <TS 1478   A       87       102         9       03H       0.83   <TS 1479   A       87       104         11       06H       0.94   <TS 1480   A       87       106         12       03H       0.85   <TS 1481   A       87       106         12       06H       0.24   <TS 1482   A       87       108         12       VS2       0.74   <TS 54 of 156
Percent No SG Row Column in Depth Location Elevation TS 1444 A
86 145 10 02C 0.65  
<TS 1445 A
87 20 15 VS4  
-0.22  
<TS 1446 A
87 20 23 VS4 0.64  
<TS 1447 A
87 20 12 VS4  
-0.91  
<TS 1448 A
87 22 11 01H 0.9  
<TS 1449 A
87 22 12 04H 0.83  
<TS 1450 A
87 22 18 VS4  
-0.93  
<TS 1451 A
87 36 9
07C 0.82  
<TS 1452 A
87 36 11 DBH 1.99  
<TS 1453 A
87 40 16 07H  
-0.95  
<TS 1454 A
87 40 7
07H  
-0.22  
<TS 1455 A
87 40 9
VS2  
-0.93  
<TS 1456 A
87 40 16 07C 0.79  
<TS 1457 A
87 40 8
VS4 0.6  
<TS 1458 A
87 56 11 05H 0.91  
<TS 1459 A
87 56 14 04C 0.92  
<TS 1460 A
87 58 15 VS2  
-0.9  
<TS 1461 A
87 60 17 VS2  
-0.84  
<TS 1462 A
87 60 10 03C 0.88  
<TS 1463 A
87 60 12 02C 0.84  
<TS 1464 A
87 82 13 05H 0.95  
<TS 1465 A
87 82 8
05C 0.9  
<TS 1466 A
87 88 9
04H 0.31  
<TS 1467 A
87 90 9
02C  
-0.2  
<TS 1468 A
87 90 10 04H 0.93  
<TS 1469 A
87 92 10 02C 0.88  
<TS 1470 A
87 92 18 04C 0.83  
<TS 1471 A
87 92 15 05C 0.85  
<TS 1472 A
87 92 10 04H 0.95  
<TS 1473 A
87 92 11 04H  
-0.74  
<TS 1474 A
87 100 13 04H 0.84  
<TS 1475 A
87 100 9
05C  
-0.88  
<TS 1476 A
87 102 20 05H 0.88  
<TS 1477 A
87 102 10 04H  
-0.09  
<TS 1478 A
87 102 9
03H 0.83  
<TS 1479 A
87 104 11 06H 0.94  
<TS 1480 A
87 106 12 03H 0.85  
<TS 1481 A
87 106 12 06H 0.24  
<TS 1482 A
87 108 12 VS2 0.74  
<TS 54 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1483   A       87       110         14       03H       0.77   <TS 1484   A       87       112         14       04H       0.88   <TS 1485   A       87       114         11       06H       0.15   <TS 1486   A       87       116         19       04C       0.83   <TS 1487   A       87       116         14       03C       -0.11   <TS 1488   A       87       120         12       VS2       0.17   <TS 1489   A       87       120         18       VS2       0.72   <TS 1490   A       87       120         11       05H       -0.15   <TS 1491   A       87       124         12       04C       -0.99   <TS 1492   A       87       136         10       03C       -0.97   <TS 1493   A       87       138         13       03H       0.87   <TS 1494   A       87       142         9       03C       -0.96   <TS 1495   A       87       144         22       03C       -0.86   <TS 1496   A       87       144         17       04C       0.88   <TS 1497   A       87       146         18       VS4       -0.96   <TS 1498   A       87       146         22       VS4       0.57   <TS 1499   A       87       146         14       02C       0.77   <TS 1500   A       88       21         25       VS4         -1   <TS 1501   A       88       21         8       VS4         0.2   <TS 1502   A       88       25         10       VS4       -0.68   <TS 1503   A       88       33         10       04H       0.84   <TS 1504   A       88       53         18       VS4         0.9   <TS 1505   A       88       53         22       07C       0.92   <TS 1506   A       88       57         13       06H       0.88   <TS 1507   A       88       57         15       VS6       0.72   <TS 1508   A       88       57         20       07C       0.94   <TS 1509   A       88       59         16       05C       0.86   <TS 1510   A       88       59         15       05C       0.15   <TS 1511   A       88       59         10       04C       0.84   <TS 1512   A       88       59         8       03C       0.93   <TS 1513   A       88       61         23       02C         0.9   <TS 1514   A       88       61         24       03C       0.46   <TS 1515   A       88       61         13       06C         0.9   <TS 1516   A       88       73         20       02H       -0.15   <TS 1517   A       88       81         13       02C         0.9   <TS 1518   A       88       83         15       04H       -0.76   <TS 1519   A       88       83         14       05H       -0.74   <TS 1520   A       88       89         16       06H       0.88   <TS 1521   A       88       89         9       05H       0.11   <TS 55 of 156
Percent No SG Row Column in Depth Location Elevation TS 1483 A
87 110 14 03H 0.77  
<TS 1484 A
87 112 14 04H 0.88  
<TS 1485 A
87 114 11 06H 0.15  
<TS 1486 A
87 116 19 04C 0.83  
<TS 1487 A
87 116 14 03C  
-0.11  
<TS 1488 A
87 120 12 VS2 0.17  
<TS 1489 A
87 120 18 VS2 0.72  
<TS 1490 A
87 120 11 05H  
-0.15  
<TS 1491 A
87 124 12 04C  
-0.99  
<TS 1492 A
87 136 10 03C  
-0.97  
<TS 1493 A
87 138 13 03H 0.87  
<TS 1494 A
87 142 9
03C  
-0.96  
<TS 1495 A
87 144 22 03C  
-0.86  
<TS 1496 A
87 144 17 04C 0.88  
<TS 1497 A
87 146 18 VS4  
-0.96  
<TS 1498 A
87 146 22 VS4 0.57  
<TS 1499 A
87 146 14 02C 0.77  
<TS 1500 A
88 21 25 VS4  
-1  
<TS 1501 A
88 21 8
VS4 0.2  
<TS 1502 A
88 25 10 VS4  
-0.68  
<TS 1503 A
88 33 10 04H 0.84  
<TS 1504 A
88 53 18 VS4 0.9  
<TS 1505 A
88 53 22 07C 0.92  
<TS 1506 A
88 57 13 06H 0.88  
<TS 1507 A
88 57 15 VS6 0.72  
<TS 1508 A
88 57 20 07C 0.94  
<TS 1509 A
88 59 16 05C 0.86  
<TS 1510 A
88 59 15 05C 0.15  
<TS 1511 A
88 59 10 04C 0.84  
<TS 1512 A
88 59 8
03C 0.93  
<TS 1513 A
88 61 23 02C 0.9  
<TS 1514 A
88 61 24 03C 0.46  
<TS 1515 A
88 61 13 06C 0.9  
<TS 1516 A
88 73 20 02H  
-0.15  
<TS 1517 A
88 81 13 02C 0.9  
<TS 1518 A
88 83 15 04H  
-0.76  
<TS 1519 A
88 83 14 05H  
-0.74  
<TS 1520 A
88 89 16 06H 0.88  
<TS 1521 A
88 89 9
05H 0.11  
<TS 55 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1522   A       88       91         14       05C       0.13   <TS 1523   A       88       91         12       04H       0.94   <TS 1524   A       88       93         9       04H       0.89   <TS 1525   A       88       99         10       06H       -0.95   <TS 1526   A       88       107         9       04C       0.15   <TS 1527   A       88       117         13       06H       0.83   <TS 1528   A       88       125         12       03C       -0.89   <TS 1529   A       88       125         14       04C       -0.85   <TS 1530   A       88       145         22       VS4       0.77   <TS 1531   A       88       145         22       04C       -0.98   <TS 1532   A       88       145         33       02C       0.18   <TS 1533   A       89       26         16       VS6       0.84   <TS 1534   A       89       28         9       VS6       0.88   <TS 1535   A       89       34         11       04H       -0.92   <TS 1536   A       89       38         8       04H       -0.92   <TS 1537   A       89       42         9       07H       -1.06   <TS 1538   A       89       42         9       07H       0.86   <TS 1539   A       89       60         7       04H       -0.84   <TS 1540   A       89       70         12       05C       -0.9   <TS 1541   A       89       70         7       05C       0.18   <TS 1542   A       89       70         16       06C       0.88   <TS 1543   A       89       72         15       01C       0.83   <TS 1544   A       89       78         16       07H       0.98   <TS 1545   A       89       78         8       07H       -0.83   <TS 1546   A       89       84         11       04H       -0.85   <TS 1547   A       89       84         6       03H       0.91   <TS 1548   A       89       108         11       04H         1   <TS 1549   A       89       108         15       05H       0.92   <TS 1550   A       89       108         22       06H       0.86   <TS 1551   A       89       112         13       05H       -0.91   <TS 1552   A       89       112         14       05H       0.15   <TS 1553   A       89       112         16       05H       0.89   <TS 1554   A       89       114         11       03H       -0.89   <TS 1555   A       89       128         15       03H       0.86   <TS 1556   A       89       128         13       05H       0.91   <TS 1557   A       89       136         15       03H       0.92   <TS 1558   A       90       23         13       VS4       -0.9   <TS 1559   A       90       25         13       VS4       0.95   <TS 1560   A       90       25         6       VS4       -0.93   <TS 56 of 156
Percent No SG Row Column in Depth Location Elevation TS 1522 A
88 91 14 05C 0.13  
<TS 1523 A
88 91 12 04H 0.94  
<TS 1524 A
88 93 9
04H 0.89  
<TS 1525 A
88 99 10 06H  
-0.95  
<TS 1526 A
88 107 9
04C 0.15  
<TS 1527 A
88 117 13 06H 0.83  
<TS 1528 A
88 125 12 03C  
-0.89  
<TS 1529 A
88 125 14 04C  
-0.85  
<TS 1530 A
88 145 22 VS4 0.77  
<TS 1531 A
88 145 22 04C  
-0.98  
<TS 1532 A
88 145 33 02C 0.18  
<TS 1533 A
89 26 16 VS6 0.84  
<TS 1534 A
89 28 9
VS6 0.88  
<TS 1535 A
89 34 11 04H  
-0.92  
<TS 1536 A
89 38 8
04H  
-0.92  
<TS 1537 A
89 42 9
07H  
-1.06  
<TS 1538 A
89 42 9
07H 0.86  
<TS 1539 A
89 60 7
04H  
-0.84  
<TS 1540 A
89 70 12 05C  
-0.9  
<TS 1541 A
89 70 7
05C 0.18  
<TS 1542 A
89 70 16 06C 0.88  
<TS 1543 A
89 72 15 01C 0.83  
<TS 1544 A
89 78 16 07H 0.98  
<TS 1545 A
89 78 8
07H  
-0.83  
<TS 1546 A
89 84 11 04H  
-0.85  
<TS 1547 A
89 84 6
03H 0.91  
<TS 1548 A
89 108 11 04H 1  
<TS 1549 A
89 108 15 05H 0.92  
<TS 1550 A
89 108 22 06H 0.86  
<TS 1551 A
89 112 13 05H  
-0.91  
<TS 1552 A
89 112 14 05H 0.15  
<TS 1553 A
89 112 16 05H 0.89  
<TS 1554 A
89 114 11 03H  
-0.89  
<TS 1555 A
89 128 15 03H 0.86  
<TS 1556 A
89 128 13 05H 0.91  
<TS 1557 A
89 136 15 03H 0.92  
<TS 1558 A
90 23 13 VS4  
-0.9  
<TS 1559 A
90 25 13 VS4 0.95  
<TS 1560 A
90 25 6
VS4  
-0.93  
<TS 56 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1561   A       90       31         10       04H       0.87   <TS 1562   A       90       35           9     05H       0.92   <TS 1563   A       90       55         13       04C       -0.92   <TS 1564   A       90       59           7     04H       -0.15   <TS 1565   A       90       59           9     04H       0.88   <TS 1566   A       90       79           8     05H       1.01   <TS 1567   A       90       79         10       06C       0.83   <TS 1568   A       90       81         11       06H         0.9   <TS 1569   A       90       87         15     03H       0.95   <TS 1570   A       90       87         19       06H       0.55   <TS 1571   A       90       87         15       02C       0.88   <TS 1572   A       90       87         11       04C       0.33   <TS 1573   A       90       91         12       03C       0.94   <TS 1574   A       90       93         12     04C         0.9   <TS 1575   A       90       93         19     03C       0.75   <TS 1576   A       90       95         10       02C       -0.94   <TS 1577   A       90       95         18       04C       0.88   <TS 1578   A       90       95         18       06C       0.88   <TS 1579   A       90       95         11     07C       0.13   <TS 1580   A       90       99         10     07H       -0.9   <TS 1581   A       90       101         10     03H       -0.88   <TS 1582   A       90       101         16       02C       0.46   <TS 1583   A       90       103           7     04H       0.86   <TS 1584   A       90       105         21       05C       0.85   <TS 1585   A       90       107         13       04H       0.91   <TS 1586   A       90       107         15       05C       0.86   <TS 1587   A       90       109         12       05H       -0.85   <TS 1588   A       90       115         16       VS6       -0.77   <TS 1589   A       90       115         12       VS6       -0.22   <TS 1590   A       90       115         11       07C       0.83   <TS 1591   A       90       115         10       03C       -0.9   <TS 1592   A       90       115         18       VS2       -0.88   <TS 1593   A       90       115           9     VS2       0.92   <TS 1594   A       90       133         11     03C       -0.99   <TS 1595   A       90       135         13       04H       0.92   <TS 1596   A       90       135         15       04C         0.9   <TS 1597   A       90       137         16       06C       0.83   <TS 1598   A       90       137           9     04C       0.07   <TS 1599   A       90       143         21       02C       -0.88   <TS 57 of 156
Percent No SG Row Column in Depth Location Elevation TS 1561 A
90 31 10 04H 0.87  
<TS 1562 A
90 35 9
05H 0.92  
<TS 1563 A
90 55 13 04C  
-0.92  
<TS 1564 A
90 59 7
04H  
-0.15  
<TS 1565 A
90 59 9
04H 0.88  
<TS 1566 A
90 79 8
05H 1.01  
<TS 1567 A
90 79 10 06C 0.83  
<TS 1568 A
90 81 11 06H 0.9  
<TS 1569 A
90 87 15 03H 0.95  
<TS 1570 A
90 87 19 06H 0.55  
<TS 1571 A
90 87 15 02C 0.88  
<TS 1572 A
90 87 11 04C 0.33  
<TS 1573 A
90 91 12 03C 0.94  
<TS 1574 A
90 93 12 04C 0.9  
<TS 1575 A
90 93 19 03C 0.75  
<TS 1576 A
90 95 10 02C  
-0.94  
<TS 1577 A
90 95 18 04C 0.88  
<TS 1578 A
90 95 18 06C 0.88  
<TS 1579 A
90 95 11 07C 0.13  
<TS 1580 A
90 99 10 07H  
-0.9  
<TS 1581 A
90 101 10 03H  
-0.88  
<TS 1582 A
90 101 16 02C 0.46  
<TS 1583 A
90 103 7
04H 0.86  
<TS 1584 A
90 105 21 05C 0.85  
<TS 1585 A
90 107 13 04H 0.91  
<TS 1586 A
90 107 15 05C 0.86  
<TS 1587 A
90 109 12 05H  
-0.85  
<TS 1588 A
90 115 16 VS6  
-0.77  
<TS 1589 A
90 115 12 VS6  
-0.22  
<TS 1590 A
90 115 11 07C 0.83  
<TS 1591 A
90 115 10 03C  
-0.9  
<TS 1592 A
90 115 18 VS2  
-0.88  
<TS 1593 A
90 115 9
VS2 0.92  
<TS 1594 A
90 133 11 03C  
-0.99  
<TS 1595 A
90 135 13 04H 0.92  
<TS 1596 A
90 135 15 04C 0.9  
<TS 1597 A
90 137 16 06C 0.83  
<TS 1598 A
90 137 9
04C 0.07  
<TS 1599 A
90 143 21 02C  
-0.88  
<TS 57 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1600   A       90       143       18       02C       0.13   <TS 1601   A       90       143       18       03C       -0.81   <TS 1602   A       90       143       11       03C       0.02   <TS 1603   A       91       22       33       VS4       0.64   <TS 1604   A       91       22       13       VS6       -0.93   <TS 1605   A       91       26         8       03H       0.91   <TS 1606   A       91       36       10       06H       -0.89   <TS 1607   A       91       40         7       DBH       1.86   <TS 1608   A       91       48       16       07C       0.11   <TS 1609   A       91       48       13       05C       -0.9   <TS 1610   A       91       54       11       03C       -0.92   <TS 1611   A       91       60       10       03C       -0.95   <TS 1612   A       91       60       11       02C       -0.18   <TS 1613   A       91       66       17       05C       0.88   <TS 1614   A       91       70       12       VS6       1.01   <TS 1615   A       91       70         7       06H       -0.09   <TS 1616   A       91       80       12       07C       0.87   <TS 1617   A       91       80       14       05C       0.87   <TS 1618   A       91       86       12       05H       0.17   <TS 1619   A       91       90       19       03C       0.83   <TS 1620   A       91       90         9       04C       0.86   <TS 1621   A       91       90       15       05H       0.54   <TS 1622   A       91       92       10       05H       0.93   <TS 1623   A       91       94       11       05C       0.13   <TS 1624   A       91       94         7       06H       0.15   <TS 1625   A       91       94       12       05H       0.19   <TS 1626   A       91       96       11       02C       0.75   <TS 1627   A       91       106       14       03C       0.77   <TS 1628   A       91       110       11       04C       -0.9   <TS 1629   A       91       114       17       VS2       -0.87   <TS 1630   A       91       116       28       VS2       -0.72   <TS 1631   A       91       128       12       04H       -0.91   <TS 1632   A       91       134       12       04H       -1.03   <TS 1633   A       91       134       10       06C       0.48   <TS 1634   A       91       136       12       04C       0.79   <TS 1635   A       91       138       12       05C       -0.93   <TS 1636   A       91       138       13       04C       0.84   <TS 1637   A       91       138       14       VS2       -0.82   <TS 1638   A       91       138         7       04C       -0.94   <TS 58 of 156
Percent No SG Row Column in Depth Location Elevation TS 1600 A
90 143 18 02C 0.13  
<TS 1601 A
90 143 18 03C  
-0.81  
<TS 1602 A
90 143 11 03C 0.02  
<TS 1603 A
91 22 33 VS4 0.64  
<TS 1604 A
91 22 13 VS6  
-0.93  
<TS 1605 A
91 26 8
03H 0.91  
<TS 1606 A
91 36 10 06H  
-0.89  
<TS 1607 A
91 40 7
DBH 1.86  
<TS 1608 A
91 48 16 07C 0.11  
<TS 1609 A
91 48 13 05C  
-0.9  
<TS 1610 A
91 54 11 03C  
-0.92  
<TS 1611 A
91 60 10 03C  
-0.95  
<TS 1612 A
91 60 11 02C  
-0.18  
<TS 1613 A
91 66 17 05C 0.88  
<TS 1614 A
91 70 12 VS6 1.01  
<TS 1615 A
91 70 7
06H  
-0.09  
<TS 1616 A
91 80 12 07C 0.87  
<TS 1617 A
91 80 14 05C 0.87  
<TS 1618 A
91 86 12 05H 0.17  
<TS 1619 A
91 90 19 03C 0.83  
<TS 1620 A
91 90 9
04C 0.86  
<TS 1621 A
91 90 15 05H 0.54  
<TS 1622 A
91 92 10 05H 0.93  
<TS 1623 A
91 94 11 05C 0.13  
<TS 1624 A
91 94 7
06H 0.15  
<TS 1625 A
91 94 12 05H 0.19  
<TS 1626 A
91 96 11 02C 0.75  
<TS 1627 A
91 106 14 03C 0.77  
<TS 1628 A
91 110 11 04C  
-0.9  
<TS 1629 A
91 114 17 VS2  
-0.87  
<TS 1630 A
91 116 28 VS2  
-0.72  
<TS 1631 A
91 128 12 04H  
-0.91  
<TS 1632 A
91 134 12 04H  
-1.03  
<TS 1633 A
91 134 10 06C 0.48  
<TS 1634 A
91 136 12 04C 0.79  
<TS 1635 A
91 138 12 05C  
-0.93  
<TS 1636 A
91 138 13 04C 0.84  
<TS 1637 A
91 138 14 VS2  
-0.82  
<TS 1638 A
91 138 7
04C  
-0.94  
<TS 58 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1639   A       91       144         13       VS4       0.66   <TS 1640   A       91       144         10       03C       -0.85   <TS 1641   A       92       23         11       04H       0.87   <TS 1642   A       92       23         19       VS2       0.55   <TS 1643   A       92       23         17       VS2       0.91   <TS 1644   A       92       23         24       VS6       1.09   <TS 1645   A       92       23           7     VS6       0.66   <TS 1646   A       92       25         12       VS4       0.93   <TS 1647   A       92       25           9     VS4       -0.99   <TS 1648   A       92       29         12     03H       0.87   <TS 1649   A       92       33         10       04H       0.87   <TS 1650   A       92       35         14       06H       0.97   <TS 1651   A       92       37         11     04H       0.89   <TS 1652   A       92       51         11     05C       0.07   <TS 1653   A       92       59         12       VS4         0.9   <TS 1654   A       92       59         11       VS6         1.1   <TS 1655   A       92       59         12     VS4       -0.9   <TS 1656   A       92       59           7     VS4       0.22   <TS 1657   A       92       69         14       05C       0.13   <TS 1658   A       92       69         12     05C       0.88   <TS 1659   A       92       77         12     06C       -0.96   <TS 1660   A       92       77         16     05C       -0.81   <TS 1661   A       92       81         12     05H         0.9   <TS 1662   A       92       81         13       06H       -0.8   <TS 1663   A       92       85         15       VS6       0.99   <TS 1664   A       92       87         13       05C       0.84   <TS 1665   A       92       87         11       03H       0.98   <TS 1666   A       92       89         17       04C       0.86   <TS 1667   A       92       89         15       05C       0.92   <TS 1668   A       92       89         15       06H       0.88   <TS 1669   A       92       93         16       04H       0.95   <TS 1670   A       92       93         12     02C       0.92   <TS 1671   A       92       97           9     05C       -0.02   <TS 1672   A       92       101         15       VS2       0.94   <TS 1673   A       92       101         16     VS2       -0.77   <TS 1674   A       92       105         11     04C       0.88   <TS 1675   A       92       107         11     04H       -0.13   <TS 1676   A       92       109         12       05C       -0.92   <TS 1677   A       92       111         12     04H       0.89   <TS 59 of 156
Percent No SG Row Column in Depth Location Elevation TS 1639 A
91 144 13 VS4 0.66  
<TS 1640 A
91 144 10 03C  
-0.85  
<TS 1641 A
92 23 11 04H 0.87  
<TS 1642 A
92 23 19 VS2 0.55  
<TS 1643 A
92 23 17 VS2 0.91  
<TS 1644 A
92 23 24 VS6 1.09  
<TS 1645 A
92 23 7
VS6 0.66  
<TS 1646 A
92 25 12 VS4 0.93  
<TS 1647 A
92 25 9
VS4  
-0.99  
<TS 1648 A
92 29 12 03H 0.87  
<TS 1649 A
92 33 10 04H 0.87  
<TS 1650 A
92 35 14 06H 0.97  
<TS 1651 A
92 37 11 04H 0.89  
<TS 1652 A
92 51 11 05C 0.07  
<TS 1653 A
92 59 12 VS4 0.9  
<TS 1654 A
92 59 11 VS6 1.1  
<TS 1655 A
92 59 12 VS4  
-0.9  
<TS 1656 A
92 59 7
VS4 0.22  
<TS 1657 A
92 69 14 05C 0.13  
<TS 1658 A
92 69 12 05C 0.88  
<TS 1659 A
92 77 12 06C  
-0.96  
<TS 1660 A
92 77 16 05C  
-0.81  
<TS 1661 A
92 81 12 05H 0.9  
<TS 1662 A
92 81 13 06H  
-0.8  
<TS 1663 A
92 85 15 VS6 0.99  
<TS 1664 A
92 87 13 05C 0.84  
<TS 1665 A
92 87 11 03H 0.98  
<TS 1666 A
92 89 17 04C 0.86  
<TS 1667 A
92 89 15 05C 0.92  
<TS 1668 A
92 89 15 06H 0.88  
<TS 1669 A
92 93 16 04H 0.95  
<TS 1670 A
92 93 12 02C 0.92  
<TS 1671 A
92 97 9
05C  
-0.02  
<TS 1672 A
92 101 15 VS2 0.94  
<TS 1673 A
92 101 16 VS2  
-0.77  
<TS 1674 A
92 105 11 04C 0.88  
<TS 1675 A
92 107 11 04H  
-0.13  
<TS 1676 A
92 109 12 05C  
-0.92  
<TS 1677 A
92 111 12 04H 0.89  
<TS 59 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1678   A       92       115       14       04C       0.79   <TS 1679   A       92       117       14       VS4       -0.81   <TS 1680   A       92       117       12       VS4       0.85   <TS 1681   A       92       125       11       03H       0.85   <TS 1682   A       92       127       10       04H         0   <TS 1683   A       92       129       11       07H       -0.83   <TS 1684   A       92       131       14       04H       0.93   <TS 1685   A       92       133       18       07H       0.87   <TS 1686   A       92       133       16       05C       -0.87   <TS 1687   A       92       133       20       04C         0.9   <TS 1688   A       92       133       14       03C       -0.92   <TS 1689   A       92       135       18       04C       0.81   <TS 1690   A       92       137       11       04C       0.85   <TS 1691   A       92       141       15       04C       0.88   <TS 1692   A       92       141       14       02C       -0.11   <TS 1693   A       93       26       13       VS4       -0.86   <TS 1694   A       93       26       11       VS4       0.86   <TS 1695   A       93       26       10       DBC       0.95   <TS 1696   A       93       52       18       04C       0.42   <TS 1697   A       93       60       12       VS6       1.01   <TS 1698   A       93       60       15       VS6       -0.98   <TS 1699   A       93       60       18       VS2       1.03   <TS 1700   A       93       60       16       VS2       -0.87   <TS 1701   A       93       70       12       04H       0.92   <TS 1702   A       93       70       14       02H       -0.83   <TS 1703   A       93       76       19       VS4       0.09   <TS 1704   A       93       76       17       VS4       0.76   <TS 1705   A       93       76       11       07C       -0.87   <TS 1706   A       93       82         9       VS2       0.92   <TS 1707   A       93       82         9       05C       -0.9   <TS 1708   A       93       84         9       03H       -0.78   <TS 1709   A       93       84       12       04H       -0.85   <TS 1710   A       93       88       14       03H       0.04   <TS 1711   A       93       94       11       04C       -0.66   <TS 1712   A       93       94         10       04C       0.84   <TS 1713   A       93       96         10       04C       -0.13   <TS 1714   A       93       100       13       VS2       -0.7   <TS 1715   A       93       104       35       VS4       -0.74   <TS 1716   A       93       104       13       DBH       1.67   <TS 60 of 156
Percent No SG Row Column in Depth Location Elevation TS 1678 A
92 115 14 04C 0.79  
<TS 1679 A
92 117 14 VS4  
-0.81  
<TS 1680 A
92 117 12 VS4 0.85  
<TS 1681 A
92 125 11 03H 0.85  
<TS 1682 A
92 127 10 04H 0  
<TS 1683 A
92 129 11 07H  
-0.83  
<TS 1684 A
92 131 14 04H 0.93  
<TS 1685 A
92 133 18 07H 0.87  
<TS 1686 A
92 133 16 05C  
-0.87  
<TS 1687 A
92 133 20 04C 0.9  
<TS 1688 A
92 133 14 03C  
-0.92  
<TS 1689 A
92 135 18 04C 0.81  
<TS 1690 A
92 137 11 04C 0.85  
<TS 1691 A
92 141 15 04C 0.88  
<TS 1692 A
92 141 14 02C  
-0.11  
<TS 1693 A
93 26 13 VS4  
-0.86  
<TS 1694 A
93 26 11 VS4 0.86  
<TS 1695 A
93 26 10 DBC 0.95  
<TS 1696 A
93 52 18 04C 0.42  
<TS 1697 A
93 60 12 VS6 1.01  
<TS 1698 A
93 60 15 VS6  
-0.98  
<TS 1699 A
93 60 18 VS2 1.03  
<TS 1700 A
93 60 16 VS2  
-0.87  
<TS 1701 A
93 70 12 04H 0.92  
<TS 1702 A
93 70 14 02H  
-0.83  
<TS 1703 A
93 76 19 VS4 0.09  
<TS 1704 A
93 76 17 VS4 0.76  
<TS 1705 A
93 76 11 07C  
-0.87  
<TS 1706 A
93 82 9
VS2 0.92  
<TS 1707 A
93 82 9
05C  
-0.9  
<TS 1708 A
93 84 9
03H  
-0.78  
<TS 1709 A
93 84 12 04H  
-0.85  
<TS 1710 A
93 88 14 03H 0.04  
<TS 1711 A
93 94 11 04C  
-0.66  
<TS 1712 A
93 94 10 04C 0.84  
<TS 1713 A
93 96 10 04C  
-0.13  
<TS 1714 A
93 100 13 VS2  
-0.7  
<TS 1715 A
93 104 35 VS4  
-0.74  
<TS 1716 A
93 104 13 DBH 1.67  
<TS 60 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1717   A       93       104       27       VS6       0.94   <TS 1718   A       93       104       13       VS6       -0.94   <TS 1719   A       93       104       13       02C       -0.88   <TS 1720   A       93       106       21       VS2       -0.72   <TS 1721   A       93       106         8       VS2       0.07   <TS 1722   A       93       114       21       VS6         0.9   <TS 1723   A       93       114       16       03C       -0.81   <TS 1724   A       93       114       12       VS6       -0.9   <TS 1725   A       93       116       11       DBH       1.53   <TS 1726   A       93       118         7       DBH       1.73   <TS 1727   A       93       130       15       03H       -0.86   <TS 1728   A       93       130       12       04H       -0.81   <TS 1729   A       93       130       21       VS2       -0.76   <TS 1730   A       93       130       16       VS2         0.9   <TS 1731   A       93       130       20       VS4       -0.87   <TS 1732   A       93       130       38       VS4       0.98   <TS 1733   A       93       132       11       04H       -0.9   <TS 1734   A       93       134       11       04H       -0.83   <TS 1735   A       93       136       15       03C       0.82   <TS 1736   A       93       136       19       03C       -0.86   <TS 1737   A       93       138       17       05C       0.83   <TS 1738   A       94       25         15       VS4       -0.95   <TS 1739   A       94       25         6       VS4       0.15   <TS 1740   A       94       25         11       03H       -0.54   <TS 1741   A       94       27         14       03H       0.84   <TS 1742   A       94       31         21       VS4       -0.94   <TS 1743   A       94       51       16       04C       0.46   <TS 1744   A       94       57       12       VS6       -0.92   <TS 1745   A       94       57       12       05C         0.9   <TS 1746   A       94       61         11       04H       0.95   <TS 1747   A       94       67         20       VS6       -0.97   <TS 1748   A       94       67         14       VS6       0.75   <TS 1749   A       94       71         9       05C       -0.9   <TS 1750   A       94       77       16       VS2       -0.85   <TS 1751   A       94       77         28       VS2       0.92   <TS 1752   A       94       77         12       VS6       -0.9   <TS 1753   A       94       85         12       02C       0.84   <TS 1754   A       94       89         12       05C       0.64   <TS 1755   A       94       91         12       05H       -0.84   <TS 61 of 156
Percent No SG Row Column in Depth Location Elevation TS 1717 A
93 104 27 VS6 0.94  
<TS 1718 A
93 104 13 VS6  
-0.94  
<TS 1719 A
93 104 13 02C  
-0.88  
<TS 1720 A
93 106 21 VS2  
-0.72  
<TS 1721 A
93 106 8
VS2 0.07  
<TS 1722 A
93 114 21 VS6 0.9  
<TS 1723 A
93 114 16 03C  
-0.81  
<TS 1724 A
93 114 12 VS6  
-0.9  
<TS 1725 A
93 116 11 DBH 1.53  
<TS 1726 A
93 118 7
DBH 1.73  
<TS 1727 A
93 130 15 03H  
-0.86  
<TS 1728 A
93 130 12 04H  
-0.81  
<TS 1729 A
93 130 21 VS2  
-0.76  
<TS 1730 A
93 130 16 VS2 0.9  
<TS 1731 A
93 130 20 VS4  
-0.87  
<TS 1732 A
93 130 38 VS4 0.98  
<TS 1733 A
93 132 11 04H  
-0.9  
<TS 1734 A
93 134 11 04H  
-0.83  
<TS 1735 A
93 136 15 03C 0.82  
<TS 1736 A
93 136 19 03C  
-0.86  
<TS 1737 A
93 138 17 05C 0.83  
<TS 1738 A
94 25 15 VS4  
-0.95  
<TS 1739 A
94 25 6
VS4 0.15  
<TS 1740 A
94 25 11 03H  
-0.54  
<TS 1741 A
94 27 14 03H 0.84  
<TS 1742 A
94 31 21 VS4  
-0.94  
<TS 1743 A
94 51 16 04C 0.46  
<TS 1744 A
94 57 12 VS6  
-0.92  
<TS 1745 A
94 57 12 05C 0.9  
<TS 1746 A
94 61 11 04H 0.95  
<TS 1747 A
94 67 20 VS6  
-0.97  
<TS 1748 A
94 67 14 VS6 0.75  
<TS 1749 A
94 71 9
05C  
-0.9  
<TS 1750 A
94 77 16 VS2  
-0.85  
<TS 1751 A
94 77 28 VS2 0.92  
<TS 1752 A
94 77 12 VS6  
-0.9  
<TS 1753 A
94 85 12 02C 0.84  
<TS 1754 A
94 89 12 05C 0.64  
<TS 1755 A
94 91 12 05H  
-0.84  
<TS 61 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1756   A       94       95       19       07C       -0.88   <TS 1757   A       94       101       20       04C       -0.94   <TS 1758   A       94       107         8       03H       -0.87   <TS 1759   A       94       109       14       04C       -0.9   <TS 1760   A       94       111       10       04H       -0.97   <TS 1761   A       94       129       10       03H       -0.88   <TS 1762   A       94       135       14       04C       0.85   <TS 1763   A       94       139       12       03C       -0.88   <TS 1764   A       94       141       16       03C       0.75   <TS 1765   A       95       24       28       VS4       -1.02   <TS 1766   A       95       24       18       VS4       0.31   <TS 1767   A       95       26         8       VS4       0.91   <TS 1768   A       95       30       34       VS4       -0.93   <TS 1769   A       95       30       29       VS4       0.86   <TS 1770   A       95       30       10       VS6       -0.07   <TS 1771   A       95       32         9       04H       -0.11   <TS 1772   A       95       48         8       07C       0.13   <TS 1773   A       95       48       19       06C       0.92   <TS 1774   A       95       48       11       07H         0.9   <TS 1775   A       95       48         7       06H       0.92   <TS 1776   A       95       48         8       07H       -0.86   <TS 1777   A       95       48         8       06C       0.11   <TS 1778   A       95       54       11       05C       0.09   <TS 1779   A       95       56       13       06C       0.86   <TS 1780   A       95       58         9       04H       1.16   <TS 1781   A       95       58       11       VS2       -0.92   <TS 1782   A       95       58         8       05C       -0.86   <TS 1783   A       95       60       12       06H       0.93   <TS 1784   A       95       72       14       07C       0.11   <TS 1785   A       95       72       11       07C       0.88   <TS 1786   A       95       74       12       06C       -0.91   <TS 1787   A       95       84       19       05C       0.88   <TS 1788   A       95       94       10       DBC       1.64   <TS 1789   A       95       94       13       04C         0   <TS 1790   A       95       104       13       02C       0.09   <TS 1791   A       95       104       10       04C       0.11   <TS 1792   A       95       110       12       04C       0.88   <TS 1793   A       95       110       14       02C       -0.94   <TS 1794   A       95       110         9       04H       0.91   <TS 62 of 156
Percent No SG Row Column in Depth Location Elevation TS 1756 A
94 95 19 07C  
-0.88  
<TS 1757 A
94 101 20 04C  
-0.94  
<TS 1758 A
94 107 8
03H  
-0.87  
<TS 1759 A
94 109 14 04C  
-0.9  
<TS 1760 A
94 111 10 04H  
-0.97  
<TS 1761 A
94 129 10 03H  
-0.88  
<TS 1762 A
94 135 14 04C 0.85  
<TS 1763 A
94 139 12 03C  
-0.88  
<TS 1764 A
94 141 16 03C 0.75  
<TS 1765 A
95 24 28 VS4  
-1.02  
<TS 1766 A
95 24 18 VS4 0.31  
<TS 1767 A
95 26 8
VS4 0.91  
<TS 1768 A
95 30 34 VS4  
-0.93  
<TS 1769 A
95 30 29 VS4 0.86  
<TS 1770 A
95 30 10 VS6  
-0.07  
<TS 1771 A
95 32 9
04H  
-0.11  
<TS 1772 A
95 48 8
07C 0.13  
<TS 1773 A
95 48 19 06C 0.92  
<TS 1774 A
95 48 11 07H 0.9  
<TS 1775 A
95 48 7
06H 0.92  
<TS 1776 A
95 48 8
07H  
-0.86  
<TS 1777 A
95 48 8
06C 0.11  
<TS 1778 A
95 54 11 05C 0.09  
<TS 1779 A
95 56 13 06C 0.86  
<TS 1780 A
95 58 9
04H 1.16  
<TS 1781 A
95 58 11 VS2  
-0.92  
<TS 1782 A
95 58 8
05C  
-0.86  
<TS 1783 A
95 60 12 06H 0.93  
<TS 1784 A
95 72 14 07C 0.11  
<TS 1785 A
95 72 11 07C 0.88  
<TS 1786 A
95 74 12 06C  
-0.91  
<TS 1787 A
95 84 19 05C 0.88  
<TS 1788 A
95 94 10 DBC 1.64  
<TS 1789 A
95 94 13 04C 0  
<TS 1790 A
95 104 13 02C 0.09  
<TS 1791 A
95 104 10 04C 0.11  
<TS 1792 A
95 110 12 04C 0.88  
<TS 1793 A
95 110 14 02C  
-0.94  
<TS 1794 A
95 110 9
04H 0.91  
<TS 62 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1795   A       95       118       13       VS2       -0.09   <TS 1796   A       95       124       19       VS2       -0.83   <TS 1797   A       95       124       23       VS2       0.92   <TS 1798   A       95       126       16       VS2       0.98   <TS 1799   A       95       130       11       04H       0.99   <TS 1800   A       95       130       11       VS2       0.02   <TS 1801   A       95       130       20       VS2       0.77   <TS 1802   A       95       130         6       VS2       -0.59   <TS 1803   A       95       132       11       VS4       0.98   <TS 1804   A       95       132       16       07C       -0.92   <TS 1805   A       95       132       13       06C       -0.85   <TS 1806   A       95       132       13       03C       -0.86   <TS 1807   A       95       132       19       VS2       0.96   <TS 1808   A       95       134       24       04C       -0.94   <TS 1809   A       95       134       13       03C       -0.98   <TS 1810   A       95       136       18       VS2       -0.89   <TS 1811   A       95       136       23       VS2       0.89   <TS 1812   A       95       140       21       04C       0.88   <TS 1813   A       95       142       15       02C       0.11   <TS 1814   A       95       142       16       02C       1.03   <TS 1815   A       96       25         16       02H         0.8   <TS 1816   A       96       25       12       04H       0.83   <TS 1817   A       96       25         35       VS4       0.77   <TS 1818   A       96       27         11       VS4         1.1   <TS 1819   A       96       31       14       VS6       -0.69   <TS 1820   A       96       31         10       VS4       0.82   <TS 1821   A       96       33         9       VS4       -0.92   <TS 1822   A       96       33         10       06H       -0.96   <TS 1823   A       96       37         16       VS6       -0.73   <TS 1824   A       96       39         10       VS6         0.2   <TS 1825   A       96       41         14       04C       0.86   <TS 1826   A       96       41         16       VS6       0.95   <TS 1827   A       96       41         11       VS6       -0.26   <TS 1828   A       96       59         12       07C       -0.72   <TS 1829   A       96       59         8       06C       -0.92   <TS 1830   A       96       59         16       04C       -0.94   <TS 1831   A       96       61         20       06C       0.09   <TS 1832   A       96       61         14       06H       0.9   <TS 1833   A       96       61         12       04H       0.09   <TS 63 of 156
Percent No SG Row Column in Depth Location Elevation TS 1795 A
95 118 13 VS2  
-0.09  
<TS 1796 A
95 124 19 VS2  
-0.83  
<TS 1797 A
95 124 23 VS2 0.92  
<TS 1798 A
95 126 16 VS2 0.98  
<TS 1799 A
95 130 11 04H 0.99  
<TS 1800 A
95 130 11 VS2 0.02  
<TS 1801 A
95 130 20 VS2 0.77  
<TS 1802 A
95 130 6
VS2  
-0.59  
<TS 1803 A
95 132 11 VS4 0.98  
<TS 1804 A
95 132 16 07C  
-0.92  
<TS 1805 A
95 132 13 06C  
-0.85  
<TS 1806 A
95 132 13 03C  
-0.86  
<TS 1807 A
95 132 19 VS2 0.96  
<TS 1808 A
95 134 24 04C  
-0.94  
<TS 1809 A
95 134 13 03C  
-0.98  
<TS 1810 A
95 136 18 VS2  
-0.89  
<TS 1811 A
95 136 23 VS2 0.89  
<TS 1812 A
95 140 21 04C 0.88  
<TS 1813 A
95 142 15 02C 0.11  
<TS 1814 A
95 142 16 02C 1.03  
<TS 1815 A
96 25 16 02H 0.8  
<TS 1816 A
96 25 12 04H 0.83  
<TS 1817 A
96 25 35 VS4 0.77  
<TS 1818 A
96 27 11 VS4 1.1  
<TS 1819 A
96 31 14 VS6  
-0.69  
<TS 1820 A
96 31 10 VS4 0.82  
<TS 1821 A
96 33 9
VS4  
-0.92  
<TS 1822 A
96 33 10 06H  
-0.96  
<TS 1823 A
96 37 16 VS6  
-0.73  
<TS 1824 A
96 39 10 VS6 0.2  
<TS 1825 A
96 41 14 04C 0.86  
<TS 1826 A
96 41 16 VS6 0.95  
<TS 1827 A
96 41 11 VS6  
-0.26  
<TS 1828 A
96 59 12 07C  
-0.72  
<TS 1829 A
96 59 8
06C  
-0.92  
<TS 1830 A
96 59 16 04C  
-0.94  
<TS 1831 A
96 61 20 06C 0.09  
<TS 1832 A
96 61 14 06H 0.9  
<TS 1833 A
96 61 12 04H 0.09  
<TS 63 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1834   A       96       63         23       04C       0.83   <TS 1835   A       96       65         13       05H       -0.92   <TS 1836   A       96       69         11       04H       0.92   <TS 1837   A       96       73         7       05H       0.91   <TS 1838   A       96       87         13       05H       0.91   <TS 1839   A       96       87         17       05C       0.86   <TS 1840   A       96       89         12       05H       -0.89   <TS 1841   A       96       89         10       04H       0.89   <TS 1842   A       96       91         7       04H       -0.81   <TS 1843   A       96       91         10       06H       -0.85   <TS 1844   A       96       91         10       04H       -0.13   <TS 1845   A       96       93         10       01C       0.09   <TS 1846   A       96       97         9       06C       0.87   <TS 1847   A       96       97         10       06C       -0.85   <TS 1848   A       96       99         11       04H       -0.13   <TS 1849   A       96       99         10       04H       -0.92   <TS 1850   A       96       103         13       05C         0.9   <TS 1851   A       96       105         8       07H       0.97   <TS 1852   A       96       105         17       VS6       -0.75   <TS 1853   A       96       109         18       04C       0.88   <TS 1854   A       96       111         20       05C       0.81   <TS 1855   A       96       111         17       04C       0.81   <TS 1856   A       96       111         12       04C       0.07   <TS 1857   A       96       113         8       VS6       -0.77   <TS 1858   A       96       117         13       VS6       -0.72   <TS 1859   A       96       117         9       VS6       -0.22   <TS 1860   A       96       119         11       05H       0.87   <TS 1861   A       96       121         20       VS6       1.07   <TS 1862   A       96       131         9       05C       0.85   <TS 1863   A       96       131         20       04C       -1.08   <TS 1864   A       96       131         10       03C       0.79   <TS 1865   A       96       141         15       VS4       1.02   <TS 1866   A       96       141         14       VS4       -0.9   <TS 1867   A       97       26         17       VS4       0.55   <TS 1868   A       97       26         15       VS4       -0.84   <TS 1869   A       97       28         10       VS4       -0.6   <TS 1870   A       97       28         12       VS4       0.93   <TS 1871   A       97       46         13       VS6       -0.77   <TS 1872   A       97       46         13       VS6       -0.22   <TS 64 of 156
Percent No SG Row Column in Depth Location Elevation TS 1834 A
96 63 23 04C 0.83  
<TS 1835 A
96 65 13 05H  
-0.92  
<TS 1836 A
96 69 11 04H 0.92  
<TS 1837 A
96 73 7
05H 0.91  
<TS 1838 A
96 87 13 05H 0.91  
<TS 1839 A
96 87 17 05C 0.86  
<TS 1840 A
96 89 12 05H  
-0.89  
<TS 1841 A
96 89 10 04H 0.89  
<TS 1842 A
96 91 7
04H  
-0.81  
<TS 1843 A
96 91 10 06H  
-0.85  
<TS 1844 A
96 91 10 04H  
-0.13  
<TS 1845 A
96 93 10 01C 0.09  
<TS 1846 A
96 97 9
06C 0.87  
<TS 1847 A
96 97 10 06C  
-0.85  
<TS 1848 A
96 99 11 04H  
-0.13  
<TS 1849 A
96 99 10 04H  
-0.92  
<TS 1850 A
96 103 13 05C 0.9  
<TS 1851 A
96 105 8
07H 0.97  
<TS 1852 A
96 105 17 VS6  
-0.75  
<TS 1853 A
96 109 18 04C 0.88  
<TS 1854 A
96 111 20 05C 0.81  
<TS 1855 A
96 111 17 04C 0.81  
<TS 1856 A
96 111 12 04C 0.07  
<TS 1857 A
96 113 8
VS6  
-0.77  
<TS 1858 A
96 117 13 VS6  
-0.72  
<TS 1859 A
96 117 9
VS6  
-0.22  
<TS 1860 A
96 119 11 05H 0.87  
<TS 1861 A
96 121 20 VS6 1.07  
<TS 1862 A
96 131 9
05C 0.85  
<TS 1863 A
96 131 20 04C  
-1.08  
<TS 1864 A
96 131 10 03C 0.79  
<TS 1865 A
96 141 15 VS4 1.02  
<TS 1866 A
96 141 14 VS4  
-0.9  
<TS 1867 A
97 26 17 VS4 0.55  
<TS 1868 A
97 26 15 VS4  
-0.84  
<TS 1869 A
97 28 10 VS4  
-0.6  
<TS 1870 A
97 28 12 VS4 0.93  
<TS 1871 A
97 46 13 VS6  
-0.77  
<TS 1872 A
97 46 13 VS6  
-0.22  
<TS 64 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1873   A       97       46           9       VS4       0.9   <TS 1874   A       97       48           9       DBC         2   <TS 1875   A       97       48         16       VS6       0.81   <TS 1876   A       97       48         14       VS6       -0.86   <TS 1877   A       97       48         16       VS4       0.92   <TS 1878   A       97       48         14       VS4       -0.97   <TS 1879   A       97       50         27       VS2       -0.9   <TS 1880   A       97       50         19       VS4       -0.86   <TS 1881   A       97       50         19       VS4       0.86   <TS 1882   A       97       50         19       VS6       0.77   <TS 1883   A       97       50         12       VS2         0.9   <TS 1884   A       97       52         18       VS2       0.88   <TS 1885   A       97       52           9       VS2       -0.84   <TS 1886   A       97       52         28       VS4       -0.81   <TS 1887   A       97       52         25       VS6       0.79   <TS 1888   A       97       54         13       05C       0.9   <TS 1889   A       97       54         16       05C       -0.51   <TS 1890   A       97       58         17       07C       0.94   <TS 1891   A       97       62         18       05C       -0.96   <TS 1892   A       97       62         20       06C       0.81   <TS 1893   A       97       64         19       06C       -0.88   <TS 1894   A       97       64         10       05H       0.99   <TS 1895   A       97       68         10       05H       0.95   <TS 1896   A       97       70         12       07H       0.88   <TS 1897   A       97       80         10       01C       0.83   <TS 1898   A       97       82         13       05C       0.88   <TS 1899   A       97       90         15       VS2       0.79   <TS 1900   A       97       90         10       VS4       0.85   <TS 1901   A       97       90         13       VS2       0.02   <TS 1902   A       97       90         14       05C       0.75   <TS 1903   A       97       90         22       VS6       -0.73   <TS 1904   A       97       90           8       VS4       -0.86   <TS 1905   A       97       90         12       VS4       -0.11   <TS 1906   A       97       96           9       VS2       0.77   <TS 1907   A       97       96         11       VS2       0.18   <TS 1908   A       97       96         12       04C       -0.86   <TS 1909   A       97       100         11       VS2       0.15   <TS 1910   A       97       106         25       VS4       -0.92   <TS 1911   A       97       106         18       VS4         0.9   <TS 65 of 156
Percent No SG Row Column in Depth Location Elevation TS 1873 A
97 46 9
VS4 0.9  
<TS 1874 A
97 48 9
DBC 2  
<TS 1875 A
97 48 16 VS6 0.81  
<TS 1876 A
97 48 14 VS6  
-0.86  
<TS 1877 A
97 48 16 VS4 0.92  
<TS 1878 A
97 48 14 VS4  
-0.97  
<TS 1879 A
97 50 27 VS2  
-0.9  
<TS 1880 A
97 50 19 VS4  
-0.86  
<TS 1881 A
97 50 19 VS4 0.86  
<TS 1882 A
97 50 19 VS6 0.77  
<TS 1883 A
97 50 12 VS2 0.9  
<TS 1884 A
97 52 18 VS2 0.88  
<TS 1885 A
97 52 9
VS2  
-0.84  
<TS 1886 A
97 52 28 VS4  
-0.81  
<TS 1887 A
97 52 25 VS6 0.79  
<TS 1888 A
97 54 13 05C 0.9  
<TS 1889 A
97 54 16 05C  
-0.51  
<TS 1890 A
97 58 17 07C 0.94  
<TS 1891 A
97 62 18 05C  
-0.96  
<TS 1892 A
97 62 20 06C 0.81  
<TS 1893 A
97 64 19 06C  
-0.88  
<TS 1894 A
97 64 10 05H 0.99  
<TS 1895 A
97 68 10 05H 0.95  
<TS 1896 A
97 70 12 07H 0.88  
<TS 1897 A
97 80 10 01C 0.83  
<TS 1898 A
97 82 13 05C 0.88  
<TS 1899 A
97 90 15 VS2 0.79  
<TS 1900 A
97 90 10 VS4 0.85  
<TS 1901 A
97 90 13 VS2 0.02  
<TS 1902 A
97 90 14 05C 0.75  
<TS 1903 A
97 90 22 VS6  
-0.73  
<TS 1904 A
97 90 8
VS4  
-0.86  
<TS 1905 A
97 90 12 VS4  
-0.11  
<TS 1906 A
97 96 9
VS2 0.77  
<TS 1907 A
97 96 11 VS2 0.18  
<TS 1908 A
97 96 12 04C  
-0.86  
<TS 1909 A
97 100 11 VS2 0.15  
<TS 1910 A
97 106 25 VS4  
-0.92  
<TS 1911 A
97 106 18 VS4 0.9  
<TS 65 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1912   A       97       112       12       VS2       0.88   <TS 1913   A       97       112       14       VS4       -0.88   <TS 1914   A       97       112       13       VS4       0.95   <TS 1915   A       97       112       10       05C         0.9   <TS 1916   A       97       114       17       VS4       -0.9   <TS 1917   A       97       116       17       VS4       -0.89   <TS 1918   A       97       116       18       05C       0.83   <TS 1919   A       97       118       23       VS4       0.66   <TS 1920   A       97       120       15       VS2       -0.9   <TS 1921   A       97       120       29       VS2       0.94   <TS 1922   A       97       120       13       VS4         0.7   <TS 1923   A       97       124       13       VS2       -0.87   <TS 1924   A       97       124       11       VS2         0.9   <TS 1925   A       97       126       15       VS4       0.13   <TS 1926   A       97       132       11       DBH       1.88   <TS 1927   A       97       132       16       VS4       0.85   <TS 1928   A       97       132       14       04C       -0.94   <TS 1929   A       97       134       21       VS4       0.92   <TS 1930   A       97       134       12       VS4       -0.88   <TS 1931   A       97       136       14       04C       -0.97   <TS 1932   A       97       138       18       02C       0.86   <TS 1933   A       97       140       13       03C       -0.95   <TS 1934   A       98       27       20       VS2       0.69   <TS 1935   A       98       27       10       VS6       -0.82   <TS 1936   A       98       27         17       VS6       0.89   <TS 1937   A       98       35       12       05H       0.83   <TS 1938   A       98       39       11       05H       0.85   <TS 1939   A       98       45         9       05H       -0.22   <TS 1940   A       98       49       11       07C       0.86   <TS 1941   A       98       51       17       05C       0.73   <TS 1942   A       98       55       18       05H       0.93   <TS 1943   A       98       55       13       DBC       -1.75   <TS 1944   A       98       59       13       05C       -0.95   <TS 1945   A       98       63       13       05C       -0.94   <TS 1946   A       98       65       20       VS2       -0.75   <TS 1947   A       98       71         8       07C       0.09   <TS 1948   A       98       75       17       06C       0.88   <TS 1949   A       98       85       10       VS6       -0.86   <TS 1950   A       98       85       10       DBC       1.63   <TS 66 of 156
Percent No SG Row Column in Depth Location Elevation TS 1912 A
97 112 12 VS2 0.88  
<TS 1913 A
97 112 14 VS4  
-0.88  
<TS 1914 A
97 112 13 VS4 0.95  
<TS 1915 A
97 112 10 05C 0.9  
<TS 1916 A
97 114 17 VS4  
-0.9  
<TS 1917 A
97 116 17 VS4  
-0.89  
<TS 1918 A
97 116 18 05C 0.83  
<TS 1919 A
97 118 23 VS4 0.66  
<TS 1920 A
97 120 15 VS2  
-0.9  
<TS 1921 A
97 120 29 VS2 0.94  
<TS 1922 A
97 120 13 VS4 0.7  
<TS 1923 A
97 124 13 VS2  
-0.87  
<TS 1924 A
97 124 11 VS2 0.9  
<TS 1925 A
97 126 15 VS4 0.13  
<TS 1926 A
97 132 11 DBH 1.88  
<TS 1927 A
97 132 16 VS4 0.85  
<TS 1928 A
97 132 14 04C  
-0.94  
<TS 1929 A
97 134 21 VS4 0.92  
<TS 1930 A
97 134 12 VS4  
-0.88  
<TS 1931 A
97 136 14 04C  
-0.97  
<TS 1932 A
97 138 18 02C 0.86  
<TS 1933 A
97 140 13 03C  
-0.95  
<TS 1934 A
98 27 20 VS2 0.69  
<TS 1935 A
98 27 10 VS6  
-0.82  
<TS 1936 A
98 27 17 VS6 0.89  
<TS 1937 A
98 35 12 05H 0.83  
<TS 1938 A
98 39 11 05H 0.85  
<TS 1939 A
98 45 9
05H  
-0.22  
<TS 1940 A
98 49 11 07C 0.86  
<TS 1941 A
98 51 17 05C 0.73  
<TS 1942 A
98 55 18 05H 0.93  
<TS 1943 A
98 55 13 DBC  
-1.75  
<TS 1944 A
98 59 13 05C  
-0.95  
<TS 1945 A
98 63 13 05C  
-0.94  
<TS 1946 A
98 65 20 VS2  
-0.75  
<TS 1947 A
98 71 8
07C 0.09  
<TS 1948 A
98 75 17 06C 0.88  
<TS 1949 A
98 85 10 VS6  
-0.86  
<TS 1950 A
98 85 10 DBC 1.63  
<TS 66 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1951   A       98       85         15       06C       0.79   <TS 1952   A       98       87         24       06C       0.85   <TS 1953   A       98       87         11     06C       -0.9   <TS 1954   A       98       95         12       03C       0.83   <TS 1955   A       98       105         22       04C       0.83   <TS 1956   A       98       105         18       05C       -0.96   <TS 1957   A       98       109         13       04H       0.91   <TS 1958   A       98       109         18     05H       -1.02   <TS 1959   A       98       109         15     07H       -0.9   <TS 1960   A       98       109         16     05C       0.86   <TS 1961   A       98       111         15       07H       0.13   <TS 1962   A       98       111         11     VS2       -0.18   <TS 1963   A       98       111         16     VS2       0.61   <TS 1964   A       98       113         12     VS2       0.61   <TS 1965   A       98       119         12     VS6         0.7   <TS 1966   A       98       125         14       VS4       0.81   <TS 1967   A       98       127         20       07H       0.81   <TS 1968   A       98       133         16     04C       0.87   <TS 1969   A       98       135         12     03C       0.11   <TS 1970   A       98       139         16     02C       -0.22   <TS 1971   A       99       26         17     VS4       -0.84   <TS 1972   A       99       26         18     VS4       -0.51   <TS 1973   A       99       28         11     VS4       0.86   <TS 1974   A       99       28         10     VS4       -0.53   <TS 1975   A       99       30         11     VS4       -0.9   <TS 1976   A       99       30           9     VS4       0.75   <TS 1977   A       99       36         13     VS4       0.86   <TS 1978   A       99       60         12       03H       -0.84   <TS 1979   A       99       70           9     06H       -0.17   <TS 1980   A       99       84         16     VS6       -0.92   <TS 1981   A       99       84         10     VS6       0.92   <TS 1982   A       99       94         16     03C       0.88   <TS 1983   A       99       96         11     07C       0.09   <TS 1984   A       99       104         16       02C       -0.92   <TS 1985   A       99       104         11     02C       0.13   <TS 1986   A       99       104         11     05C       -0.9   <TS 1987   A       99       106         13     02C       -0.94   <TS 1988   A       99       112         18     04C         0.9   <TS 1989   A       99       116         13     VS4       -0.9   <TS 67 of 156
Percent No SG Row Column in Depth Location Elevation TS 1951 A
98 85 15 06C 0.79  
<TS 1952 A
98 87 24 06C 0.85  
<TS 1953 A
98 87 11 06C  
-0.9  
<TS 1954 A
98 95 12 03C 0.83  
<TS 1955 A
98 105 22 04C 0.83  
<TS 1956 A
98 105 18 05C  
-0.96  
<TS 1957 A
98 109 13 04H 0.91  
<TS 1958 A
98 109 18 05H  
-1.02  
<TS 1959 A
98 109 15 07H  
-0.9  
<TS 1960 A
98 109 16 05C 0.86  
<TS 1961 A
98 111 15 07H 0.13  
<TS 1962 A
98 111 11 VS2  
-0.18  
<TS 1963 A
98 111 16 VS2 0.61  
<TS 1964 A
98 113 12 VS2 0.61  
<TS 1965 A
98 119 12 VS6 0.7  
<TS 1966 A
98 125 14 VS4 0.81  
<TS 1967 A
98 127 20 07H 0.81  
<TS 1968 A
98 133 16 04C 0.87  
<TS 1969 A
98 135 12 03C 0.11  
<TS 1970 A
98 139 16 02C  
-0.22  
<TS 1971 A
99 26 17 VS4  
-0.84  
<TS 1972 A
99 26 18 VS4  
-0.51  
<TS 1973 A
99 28 11 VS4 0.86  
<TS 1974 A
99 28 10 VS4  
-0.53  
<TS 1975 A
99 30 11 VS4  
-0.9  
<TS 1976 A
99 30 9
VS4 0.75  
<TS 1977 A
99 36 13 VS4 0.86  
<TS 1978 A
99 60 12 03H  
-0.84  
<TS 1979 A
99 70 9
06H  
-0.17  
<TS 1980 A
99 84 16 VS6  
-0.92  
<TS 1981 A
99 84 10 VS6 0.92  
<TS 1982 A
99 94 16 03C 0.88  
<TS 1983 A
99 96 11 07C 0.09  
<TS 1984 A
99 104 16 02C  
-0.92  
<TS 1985 A
99 104 11 02C 0.13  
<TS 1986 A
99 104 11 05C  
-0.9  
<TS 1987 A
99 106 13 02C  
-0.94  
<TS 1988 A
99 112 18 04C 0.9  
<TS 1989 A
99 116 13 VS4  
-0.9  
<TS 67 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 1990   A       99       118         9       04H       0.15   <TS 1991   A       99       136       12       VS4       -0.9   <TS 1992   A       99       136         8       VS4       0.72   <TS 1993   A       99       138       13       03H       0.86   <TS 1994   A       99       138       16       VS4       0.09   <TS 1995   A       99       138       19       VS4       0.76   <TS 1996   A       99       138       14       02C       0.07   <TS 1997   A       99       138       15       02C       -0.96   <TS 1998   A       99       138       17       03C       -0.44   <TS 1999   A       99       140       28       VS4       -0.83   <TS 2000   A       99       140       17       03C       -0.15   <TS 2001   A       99       140       16       03C       -0.97   <TS 2002   A       100       27         23       VS4       -0.88   <TS 2003   A       100       27         14       VS4       -0.2   <TS 2004   A       100       27         12       VS4       0.99   <TS 2005   A       100       29       12       04H       0.87   <TS 2006   A       100       29       14       05H       0.85   <TS 2007   A       100       29         15       06H       0.91   <TS 2008   A       100       29       11       VS2       -0.86   <TS 2009   A       100       29       19       VS2       0.91   <TS 2010   A       100       29         15       VS4       0.93   <TS 2011   A       100       29         11       VS4       0.07   <TS 2012   A       100       31       14       VS2       -0.89   <TS 2013   A       100       31         13       06H       -0.09   <TS 2014   A       100       31         10       06H       -0.89   <TS 2015   A       100       31       12       04H       0.84   <TS 2016   A       100       33       10       VS2       -0.86   <TS 2017   A       100       35       12       03H       -0.8   <TS 2018   A       100       35         8       05C       0.15   <TS 2019   A       100       41         12       06C       0.75   <TS 2020   A       100       49         12       05C       0.88   <TS 2021   A       100       51         9       06H       -0.06   <TS 2022   A       100       61         12       03H       -0.86   <TS 2023   A       100       65       11       06H       -0.91   <TS 2024   A       100       67         28       VS6       -0.95   <TS 2025   A       100       75       10       06C         0.9   <TS 2026   A       100       87       10       05C       0.86   <TS 2027   A       100       87       10       04H       -0.74   <TS 2028   A       100       89       14       03C       0.85   <TS 68 of 156
Percent No SG Row Column in Depth Location Elevation TS 1990 A
99 118 9
04H 0.15  
<TS 1991 A
99 136 12 VS4  
-0.9  
<TS 1992 A
99 136 8
VS4 0.72  
<TS 1993 A
99 138 13 03H 0.86  
<TS 1994 A
99 138 16 VS4 0.09  
<TS 1995 A
99 138 19 VS4 0.76  
<TS 1996 A
99 138 14 02C 0.07  
<TS 1997 A
99 138 15 02C  
-0.96  
<TS 1998 A
99 138 17 03C  
-0.44  
<TS 1999 A
99 140 28 VS4  
-0.83  
<TS 2000 A
99 140 17 03C  
-0.15  
<TS 2001 A
99 140 16 03C  
-0.97  
<TS 2002 A
100 27 23 VS4  
-0.88  
<TS 2003 A
100 27 14 VS4  
-0.2  
<TS 2004 A
100 27 12 VS4 0.99  
<TS 2005 A
100 29 12 04H 0.87  
<TS 2006 A
100 29 14 05H 0.85  
<TS 2007 A
100 29 15 06H 0.91  
<TS 2008 A
100 29 11 VS2  
-0.86  
<TS 2009 A
100 29 19 VS2 0.91  
<TS 2010 A
100 29 15 VS4 0.93  
<TS 2011 A
100 29 11 VS4 0.07  
<TS 2012 A
100 31 14 VS2  
-0.89  
<TS 2013 A
100 31 13 06H  
-0.09  
<TS 2014 A
100 31 10 06H  
-0.89  
<TS 2015 A
100 31 12 04H 0.84  
<TS 2016 A
100 33 10 VS2  
-0.86  
<TS 2017 A
100 35 12 03H  
-0.8  
<TS 2018 A
100 35 8
05C 0.15  
<TS 2019 A
100 41 12 06C 0.75  
<TS 2020 A
100 49 12 05C 0.88  
<TS 2021 A
100 51 9
06H  
-0.06  
<TS 2022 A
100 61 12 03H  
-0.86  
<TS 2023 A
100 65 11 06H  
-0.91  
<TS 2024 A
100 67 28 VS6  
-0.95  
<TS 2025 A
100 75 10 06C 0.9  
<TS 2026 A
100 87 10 05C 0.86  
<TS 2027 A
100 87 10 04H  
-0.74  
<TS 2028 A
100 89 14 03C 0.85  
<TS 68 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2029   A       100       89         10       04C       -0.94   <TS 2030   A       100       89         17       VS2       -0.79   <TS 2031   A       100       99         14       05C       0.87   <TS 2032   A       100     103         14       05C       -0.97   <TS 2033   A       100     103         18       02C       0.88   <TS 2034   A       100     107         21       VS4       -0.9   <TS 2035   A       100     107         12       04C         0.9   <TS 2036   A       100     113         15       DBH       1.92   <TS 2037   A       100     115         17       05H       -0.87   <TS 2038   A       100     115         12       03C       0.83   <TS 2039   A       100     119         23       VS2       -0.79   <TS 2040   A       100     119         25       VS2         0   <TS 2041   A       100     119         14       VS4       -0.9   <TS 2042   A       100     119         15       VS6       0.94   <TS 2043   A       100     119         10       VS2       0.75   <TS 2044   A       100     131         10       05C       0.83   <TS 2045   A       100     133         14       DBH       1.99   <TS 2046   A       100     137         13       VS4       -0.9   <TS 2047   A       100     137         12       VS4       0.83   <TS 2048   A       100     137         18       05C       -0.92   <TS 2049   A       100     137         13       04C       0.83   <TS 2050   A       100     137         34       03C       -0.6   <TS 2051   A       100     139         19       VS4       -0.9   <TS 2052   A       100     139         15       03C       -0.13   <TS 2053   A       101       28         10       03H       0.93   <TS 2054   A       101       28         17       VS4       -0.83   <TS 2055   A       101       28         20       VS4         0.7   <TS 2056   A       101       30         17       04H       -0.17   <TS 2057   A       101       30         13       VS4       -0.92   <TS 2058   A       101       30         10       VS4       0.73   <TS 2059   A       101       36         10       03H       0.86   <TS 2060   A       101       40         9       05H       0.11   <TS 2061   A       101       44         13       VS2       0.81   <TS 2062   A       101       48         14       DBC       1.78   <TS 2063   A       101       56         13       06C       -0.99   <TS 2064   A       101       68         12       06H       0.83   <TS 2065   A       101       70         12       07C       -0.22   <TS 2066   A       101       70         14       05H       0.87   <TS 2067   A       101       78         8       07H       -0.83   <TS 69 of 156
Percent No SG Row Column in Depth Location Elevation TS 2029 A
100 89 10 04C  
-0.94  
<TS 2030 A
100 89 17 VS2  
-0.79  
<TS 2031 A
100 99 14 05C 0.87  
<TS 2032 A
100 103 14 05C  
-0.97  
<TS 2033 A
100 103 18 02C 0.88  
<TS 2034 A
100 107 21 VS4  
-0.9  
<TS 2035 A
100 107 12 04C 0.9  
<TS 2036 A
100 113 15 DBH 1.92  
<TS 2037 A
100 115 17 05H  
-0.87  
<TS 2038 A
100 115 12 03C 0.83  
<TS 2039 A
100 119 23 VS2  
-0.79  
<TS 2040 A
100 119 25 VS2 0  
<TS 2041 A
100 119 14 VS4  
-0.9  
<TS 2042 A
100 119 15 VS6 0.94  
<TS 2043 A
100 119 10 VS2 0.75  
<TS 2044 A
100 131 10 05C 0.83  
<TS 2045 A
100 133 14 DBH 1.99  
<TS 2046 A
100 137 13 VS4  
-0.9  
<TS 2047 A
100 137 12 VS4 0.83  
<TS 2048 A
100 137 18 05C  
-0.92  
<TS 2049 A
100 137 13 04C 0.83  
<TS 2050 A
100 137 34 03C  
-0.6  
<TS 2051 A
100 139 19 VS4  
-0.9  
<TS 2052 A
100 139 15 03C  
-0.13  
<TS 2053 A
101 28 10 03H 0.93  
<TS 2054 A
101 28 17 VS4  
-0.83  
<TS 2055 A
101 28 20 VS4 0.7  
<TS 2056 A
101 30 17 04H  
-0.17  
<TS 2057 A
101 30 13 VS4  
-0.92  
<TS 2058 A
101 30 10 VS4 0.73  
<TS 2059 A
101 36 10 03H 0.86  
<TS 2060 A
101 40 9
05H 0.11  
<TS 2061 A
101 44 13 VS2 0.81  
<TS 2062 A
101 48 14 DBC 1.78  
<TS 2063 A
101 56 13 06C  
-0.99  
<TS 2064 A
101 68 12 06H 0.83  
<TS 2065 A
101 70 12 07C  
-0.22  
<TS 2066 A
101 70 14 05H 0.87  
<TS 2067 A
101 78 8
07H  
-0.83  
<TS 69 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2068   A       101       78         7       07H         0.2   <TS 2069   A       101       86         10       07C       0.77   <TS 2070   A       101     102         12       04C       0.09   <TS 2071   A       101     104         9       05C       -0.11   <TS 2072   A       101     106         13       04C       0.86   <TS 2073   A       101     108         12       VS2       0.77   <TS 2074   A       101     110         8       VS2       0.18   <TS 2075   A       101     110         13       VS2       0.79   <TS 2076   A       101     112         13       06H       0.86   <TS 2077   A       101     114         10       VS2       -0.92   <TS 2078   A       101     114         14       07C       -0.9   <TS 2079   A       101     114         14       03C       -0.83   <TS 2080   A       101     118         15       DBH       1.64   <TS 2081   A       101     120         11       03C       0.87   <TS 2082   A       101     124         16       07C       0.85   <TS 2083   A       101     128         13       04H       -0.9   <TS 2084   A       101     132         10       03C       0.88   <TS 2085   A       101     136         13       03C       -0.87   <TS 2086   A       101     136         14       02C         0   <TS 2087   A       101     138         20       VS4       0.85   <TS 2088   A       101     138         9       07C       0.79   <TS 2089   A       102       29         20       VS4       -0.95   <TS 2090   A       102       29         12       VS4       -0.11   <TS 2091   A       102       29         13       04C       -0.9   <TS 2092   A       102       31         8       02C       0.86   <TS 2093   A       102       31         10       07C       0.75   <TS 2094   A       102       31         9       03H       0.88   <TS 2095   A       102       49         9       06H       0.88   <TS 2096   A       102       55         12       03C       -0.9   <TS 2097   A       102       67         10       07C       0.04   <TS 2098   A       102       67         13       07H         0.9   <TS 2099   A       102       73         13       07C       -0.9   <TS 2100   A       102       75         11       VS2       -0.94   <TS 2101   A       102       83         10       01C       0.81   <TS 2102   A       102       85         8       05C       0.77   <TS 2103   A       102       89         8       03H       0.91   <TS 2104   A       102       89         17       04C       0.81   <TS 2105   A       102       91         11       04C       -0.88   <TS 2106   A       102       95         14       02C       -0.85   <TS 70 of 156
Percent No SG Row Column in Depth Location Elevation TS 2068 A
101 78 7
07H 0.2  
<TS 2069 A
101 86 10 07C 0.77  
<TS 2070 A
101 102 12 04C 0.09  
<TS 2071 A
101 104 9
05C  
-0.11  
<TS 2072 A
101 106 13 04C 0.86  
<TS 2073 A
101 108 12 VS2 0.77  
<TS 2074 A
101 110 8
VS2 0.18  
<TS 2075 A
101 110 13 VS2 0.79  
<TS 2076 A
101 112 13 06H 0.86  
<TS 2077 A
101 114 10 VS2  
-0.92  
<TS 2078 A
101 114 14 07C  
-0.9  
<TS 2079 A
101 114 14 03C  
-0.83  
<TS 2080 A
101 118 15 DBH 1.64  
<TS 2081 A
101 120 11 03C 0.87  
<TS 2082 A
101 124 16 07C 0.85  
<TS 2083 A
101 128 13 04H  
-0.9  
<TS 2084 A
101 132 10 03C 0.88  
<TS 2085 A
101 136 13 03C  
-0.87  
<TS 2086 A
101 136 14 02C 0  
<TS 2087 A
101 138 20 VS4 0.85  
<TS 2088 A
101 138 9
07C 0.79  
<TS 2089 A
102 29 20 VS4  
-0.95  
<TS 2090 A
102 29 12 VS4  
-0.11  
<TS 2091 A
102 29 13 04C  
-0.9  
<TS 2092 A
102 31 8
02C 0.86  
<TS 2093 A
102 31 10 07C 0.75  
<TS 2094 A
102 31 9
03H 0.88  
<TS 2095 A
102 49 9
06H 0.88  
<TS 2096 A
102 55 12 03C  
-0.9  
<TS 2097 A
102 67 10 07C 0.04  
<TS 2098 A
102 67 13 07H 0.9  
<TS 2099 A
102 73 13 07C  
-0.9  
<TS 2100 A
102 75 11 VS2  
-0.94  
<TS 2101 A
102 83 10 01C 0.81  
<TS 2102 A
102 85 8
05C 0.77  
<TS 2103 A
102 89 8
03H 0.91  
<TS 2104 A
102 89 17 04C 0.81  
<TS 2105 A
102 91 11 04C  
-0.88  
<TS 2106 A
102 95 14 02C  
-0.85  
<TS 70 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2107   A       102       95         14       05C       -0.15   <TS 2108   A       102     105         9       02C       0.09   <TS 2109   A       102     105         8       03C       0.07   <TS 2110   A       102     105         13       03C       -0.9   <TS 2111   A       102     105         16       05C       0.81   <TS 2112   A       102     107         12       VS2       0.66   <TS 2113   A       102     113         12       05C       0.83   <TS 2114   A       102     115         14       VS2       -0.81   <TS 2115   A       102     115         20       VS2       -0.07   <TS 2116   A       102     117         24       03H       0.88   <TS 2117   A       102     121         25       VS4       -0.92   <TS 2118   A       102     133         13       03C       -0.93   <TS 2119   A       102     135         15       04C       0.81   <TS 2120   A       102     135         15       03C       -0.2   <TS 2121   A       102     135         7       02C       0.74   <TS 2122   A       102     137         14       04C       -0.94   <TS 2123   A       103       30         11       05H       -0.89   <TS 2124   A       103       30         10       07H       -0.93   <TS 2125   A       103       30         17       VS4       0.62   <TS 2126   A       103       30         7       05C       0.84   <TS 2127   A       103       30         8       06H       -1.03   <TS 2128   A       103       30         10       VS4       -0.11   <TS 2129   A       103       32         12       02C       -0.18   <TS 2130   A       103       32         9       03C       0.07   <TS 2131   A       103       32         18       VS4       -0.91   <TS 2132   A       103       32         7       VS4       0.58   <TS 2133   A       103       36         7       VS2       -0.91   <TS 2134   A       103       36         9       VS2       0.95   <TS 2135   A       103       36         10       05C       -0.91   <TS 2136   A       103       54         13       05H       0.95   <TS 2137   A       103       54         10       04H       -0.97   <TS 2138   A       103       82         15       06H       0.92   <TS 2139   A       103       82         8       06H       -0.11   <TS 2140   A       103       82         17       05H       -0.06   <TS 2141   A       103       82         11       05H       -0.85   <TS 2142   A       103       84         10       07H       0.92   <TS 2143   A       103       86         19       VS2       0.15   <TS 2144   A       103       86         15       VS2       0.66   <TS 2145   A       103       92         9       04C       -0.88   <TS 71 of 156
Percent No SG Row Column in Depth Location Elevation TS 2107 A
102 95 14 05C  
-0.15  
<TS 2108 A
102 105 9
02C 0.09  
<TS 2109 A
102 105 8
03C 0.07  
<TS 2110 A
102 105 13 03C  
-0.9  
<TS 2111 A
102 105 16 05C 0.81  
<TS 2112 A
102 107 12 VS2 0.66  
<TS 2113 A
102 113 12 05C 0.83  
<TS 2114 A
102 115 14 VS2  
-0.81  
<TS 2115 A
102 115 20 VS2  
-0.07  
<TS 2116 A
102 117 24 03H 0.88  
<TS 2117 A
102 121 25 VS4  
-0.92  
<TS 2118 A
102 133 13 03C  
-0.93  
<TS 2119 A
102 135 15 04C 0.81  
<TS 2120 A
102 135 15 03C  
-0.2  
<TS 2121 A
102 135 7
02C 0.74  
<TS 2122 A
102 137 14 04C  
-0.94  
<TS 2123 A
103 30 11 05H  
-0.89  
<TS 2124 A
103 30 10 07H  
-0.93  
<TS 2125 A
103 30 17 VS4 0.62  
<TS 2126 A
103 30 7
05C 0.84  
<TS 2127 A
103 30 8
06H  
-1.03  
<TS 2128 A
103 30 10 VS4  
-0.11  
<TS 2129 A
103 32 12 02C  
-0.18  
<TS 2130 A
103 32 9
03C 0.07  
<TS 2131 A
103 32 18 VS4  
-0.91  
<TS 2132 A
103 32 7
VS4 0.58  
<TS 2133 A
103 36 7
VS2  
-0.91  
<TS 2134 A
103 36 9
VS2 0.95  
<TS 2135 A
103 36 10 05C  
-0.91  
<TS 2136 A
103 54 13 05H 0.95  
<TS 2137 A
103 54 10 04H  
-0.97  
<TS 2138 A
103 82 15 06H 0.92  
<TS 2139 A
103 82 8
06H  
-0.11  
<TS 2140 A
103 82 17 05H  
-0.06  
<TS 2141 A
103 82 11 05H  
-0.85  
<TS 2142 A
103 84 10 07H 0.92  
<TS 2143 A
103 86 19 VS2 0.15  
<TS 2144 A
103 86 15 VS2 0.66  
<TS 2145 A
103 92 9
04C  
-0.88  
<TS 71 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2146   A       103     92         11       04C       0.85   <TS 2147   A       103     92         16       05C       0.85   <TS 2148   A       103     96         13       05C         0.9   <TS 2149   A       103     100         9       05C       -0.86   <TS 2150   A       103     102         11       03C       -0.15   <TS 2151   A       103     108         17       07C       -0.15   <TS 2152   A       103     118         13       04C       -0.99   <TS 2153   A       103     122         10       07C         0.9   <TS 2154   A       103     122         18       DBC       1.69   <TS 2155   A       103     134         12       04C       0.92   <TS 2156   A       103     134         14       04C       0.07   <TS 2157   A       103     136         13       02C       0.87   <TS 2158   A       104       31         20       VS4       -0.93   <TS 2159   A       104       31         21       VS4       0.84   <TS 2160   A       104       33         12       03C       -0.86   <TS 2161   A       104       33         11       04C       -0.83   <TS 2162   A       104     61         14       06C         0.9   <TS 2163   A       104       63         12       05C       -0.9   <TS 2164   A       104     63         14       07C       -0.92   <TS 2165   A       104     69         11       07H       -0.94   <TS 2166   A       104       71         12       DBH       1.99   <TS 2167   A       104       77         11       06C       0.88   <TS 2168   A       104     85         13       VS2       -0.88   <TS 2169   A       104     85         18       04C       -0.94   <TS 2170   A       104     85         12       04C       0.79   <TS 2171   A       104     87         11       04C       -0.2   <TS 2172   A       104     87         22       04C       -0.9   <TS 2173   A       104     89         15       02C       -0.9   <TS 2174   A       104     93         12       06H         0.9   <TS 2175   A       104     95         17       VS2       -0.77   <TS 2176   A       104     97         10       03C         0   <TS 2177   A       104     97         12       03C       0.89   <TS 2178   A       104     97         20       04C       -0.94   <TS 2179   A       104     99         15       06C       0.88   <TS 2180   A       104     103         13       05C       0.92   <TS 2181   A       104     103         7       DBC       -1.77   <TS 2182   A       104     109         16       VS6       -0.66   <TS 2183   A       104     121         13       07C       0.85   <TS 2184   A       104     121         16       06C       0.85   <TS 72 of 156
Percent No SG Row Column in Depth Location Elevation TS 2146 A
103 92 11 04C 0.85  
<TS 2147 A
103 92 16 05C 0.85  
<TS 2148 A
103 96 13 05C 0.9  
<TS 2149 A
103 100 9
05C  
-0.86  
<TS 2150 A
103 102 11 03C  
-0.15  
<TS 2151 A
103 108 17 07C  
-0.15  
<TS 2152 A
103 118 13 04C  
-0.99  
<TS 2153 A
103 122 10 07C 0.9  
<TS 2154 A
103 122 18 DBC 1.69  
<TS 2155 A
103 134 12 04C 0.92  
<TS 2156 A
103 134 14 04C 0.07  
<TS 2157 A
103 136 13 02C 0.87  
<TS 2158 A
104 31 20 VS4  
-0.93  
<TS 2159 A
104 31 21 VS4 0.84  
<TS 2160 A
104 33 12 03C  
-0.86  
<TS 2161 A
104 33 11 04C  
-0.83  
<TS 2162 A
104 61 14 06C 0.9  
<TS 2163 A
104 63 12 05C  
-0.9  
<TS 2164 A
104 63 14 07C  
-0.92  
<TS 2165 A
104 69 11 07H  
-0.94  
<TS 2166 A
104 71 12 DBH 1.99  
<TS 2167 A
104 77 11 06C 0.88  
<TS 2168 A
104 85 13 VS2  
-0.88  
<TS 2169 A
104 85 18 04C  
-0.94  
<TS 2170 A
104 85 12 04C 0.79  
<TS 2171 A
104 87 11 04C  
-0.2  
<TS 2172 A
104 87 22 04C  
-0.9  
<TS 2173 A
104 89 15 02C  
-0.9  
<TS 2174 A
104 93 12 06H 0.9  
<TS 2175 A
104 95 17 VS2  
-0.77  
<TS 2176 A
104 97 10 03C 0  
<TS 2177 A
104 97 12 03C 0.89  
<TS 2178 A
104 97 20 04C  
-0.94  
<TS 2179 A
104 99 15 06C 0.88  
<TS 2180 A
104 103 13 05C 0.92  
<TS 2181 A
104 103 7
DBC  
-1.77  
<TS 2182 A
104 109 16 VS6  
-0.66  
<TS 2183 A
104 121 13 07C 0.85  
<TS 2184 A
104 121 16 06C 0.85  
<TS 72 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2185   A       104     123       11       03C       -0.83   <TS 2186   A       104     123       14       04C       0.94   <TS 2187   A       104     133       13       05C       -0.15   <TS 2188   A       104     135       27       03C       0.88   <TS 2189   A       105       30       23       VS4       -0.58   <TS 2190   A       105       32       14       01C       0.09   <TS 2191   A       105     32         12       04H       -0.86   <TS 2192   A       105       90       15       05C       0.84   <TS 2193   A       105       92       12       07C       -0.9   <TS 2194   A       105     112       16       05H       0.95   <TS 2195   A       105     112         8       06H       -0.04   <TS 2196   A       105     120       11       04C         0.9   <TS 2197   A       105     120       12       03C       -0.96   <TS 2198   A       105     122       13       06C       0.85   <TS 2199   A       105     132       20       03C       0.85   <TS 2200   A       105     136       15       VS4       -0.9   <TS 2201   A       105     136       13       VS4       0.96   <TS 2202   A       106       31       12       01C       -0.9   <TS 2203   A       106       31       13       03C       0.87   <TS 2204   A       106       31       19       04C       0.77   <TS 2205   A       106       31       28       VS6       0.84   <TS 2206   A       106       31       14       VS6       0.29   <TS 2207   A       106       31       32       VS6       -0.86   <TS 2208   A       106       31       12       VS4       0.95   <TS 2209   A       106       31         8       VS2       0.11   <TS 2210   A       106       33       13       VS4       -1.06   <TS 2211   A       106       33       18       VS4       -0.75   <TS 2212   A       106       33       12       04C       -0.94   <TS 2213   A       106     35         18       03C       0.95   <TS 2214   A       106       35       15       03C       0.09   <TS 2215   A       106     43         10       07H       -0.95   <TS 2216   A       106     45         9       05H       -0.15   <TS 2217   A       106     47         11       DBC       1.63   <TS 2218   A       106     47         11       04C       0.09   <TS 2219   A       106     47         15       04C       0.84   <TS 2220   A       106       57       18       07H       0.92   <TS 2221   A       106       59       24       VS4       -1.15   <TS 2222   A       106       59       35       VS4       0.84   <TS 2223   A       106       59       18       VS6       -0.71   <TS 73 of 156
Percent No SG Row Column in Depth Location Elevation TS 2185 A
104 123 11 03C  
-0.83  
<TS 2186 A
104 123 14 04C 0.94  
<TS 2187 A
104 133 13 05C  
-0.15  
<TS 2188 A
104 135 27 03C 0.88  
<TS 2189 A
105 30 23 VS4  
-0.58  
<TS 2190 A
105 32 14 01C 0.09  
<TS 2191 A
105 32 12 04H  
-0.86  
<TS 2192 A
105 90 15 05C 0.84  
<TS 2193 A
105 92 12 07C  
-0.9  
<TS 2194 A
105 112 16 05H 0.95  
<TS 2195 A
105 112 8
06H  
-0.04  
<TS 2196 A
105 120 11 04C 0.9  
<TS 2197 A
105 120 12 03C  
-0.96  
<TS 2198 A
105 122 13 06C 0.85  
<TS 2199 A
105 132 20 03C 0.85  
<TS 2200 A
105 136 15 VS4  
-0.9  
<TS 2201 A
105 136 13 VS4 0.96  
<TS 2202 A
106 31 12 01C  
-0.9  
<TS 2203 A
106 31 13 03C 0.87  
<TS 2204 A
106 31 19 04C 0.77  
<TS 2205 A
106 31 28 VS6 0.84  
<TS 2206 A
106 31 14 VS6 0.29  
<TS 2207 A
106 31 32 VS6  
-0.86  
<TS 2208 A
106 31 12 VS4 0.95  
<TS 2209 A
106 31 8
VS2 0.11  
<TS 2210 A
106 33 13 VS4  
-1.06  
<TS 2211 A
106 33 18 VS4  
-0.75  
<TS 2212 A
106 33 12 04C  
-0.94  
<TS 2213 A
106 35 18 03C 0.95  
<TS 2214 A
106 35 15 03C 0.09  
<TS 2215 A
106 43 10 07H  
-0.95  
<TS 2216 A
106 45 9
05H  
-0.15  
<TS 2217 A
106 47 11 DBC 1.63  
<TS 2218 A
106 47 11 04C 0.09  
<TS 2219 A
106 47 15 04C 0.84  
<TS 2220 A
106 57 18 07H 0.92  
<TS 2221 A
106 59 24 VS4  
-1.15  
<TS 2222 A
106 59 35 VS4 0.84  
<TS 2223 A
106 59 18 VS6  
-0.71  
<TS 73 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2224   A       106       59         13       VS2       -0.88   <TS 2225   A       106       59         10       DBH       1.61   <TS 2226   A       106       63         13       VS4       -1.03   <TS 2227   A       106       63         14       VS4       0.33   <TS 2228   A       106       67         20       VS6       0.39   <TS 2229   A       106       67         12       VS4       -0.7   <TS 2230   A       106       69         12       07C       -0.13   <TS 2231   A       106       69         15       VS2       0.24   <TS 2232   A       106       69         11       VS6       0.94   <TS 2233   A       106       69         12       VS4       -1.19   <TS 2234   A       106       95         12       DBH       -1.69   <TS 2235   A       106     101         17       04H       0.91   <TS 2236   A       106     101           9     06C       0.09   <TS 2237   A       106     111         15       DBC         1.6   <TS 2238   A       106     117         14     VS2       -0.26   <TS 2239   A       106     117         17     06C       -0.92   <TS 2240   A       106     117           8     04H       0.64   <TS 2241   A       106     119         14     VS4       1.03   <TS 2242   A       106     119           9     04C       -0.88   <TS 2243   A       106     119           8     VS4       -1.09   <TS 2244   A       106     121         17       04C       0.88   <TS 2245   A       106     121           9     04C       0.13   <TS 2246   A       106     121         15     05C       0.11   <TS 2247   A       106     125           9     06C       0.86   <TS 2248   A       106     131         11     04H       -0.88   <TS 2249   A       106     131         20       03C       -0.53   <TS 2250   A       106     133         20       DBC       1.64   <TS 2251   A       106     133         12       03C       0.85   <TS 2252   A       106     135           9     01H       0.08   <TS 2253   A       106     135         24       VS4       -0.81   <TS 2254   A       106     135         13       03C       -0.83   <TS 2255   A       107       32         13       03C       0.98   <TS 2256   A       107       32         13       04C       -0.24   <TS 2257   A       107       32           5     04C         -1   <TS 2258   A       107       32         11       VS4       -0.29   <TS 2259   A       107       32         33       VS4       -0.8   <TS 2260   A       107       34           9     VS4       0.88   <TS 2261   A       107       34         10     01H       0.86   <TS 2262   A       107       36         10     03C       0.84   <TS 74 of 156
Percent No SG Row Column in Depth Location Elevation TS 2224 A
106 59 13 VS2  
-0.88  
<TS 2225 A
106 59 10 DBH 1.61  
<TS 2226 A
106 63 13 VS4  
-1.03  
<TS 2227 A
106 63 14 VS4 0.33  
<TS 2228 A
106 67 20 VS6 0.39  
<TS 2229 A
106 67 12 VS4  
-0.7  
<TS 2230 A
106 69 12 07C  
-0.13  
<TS 2231 A
106 69 15 VS2 0.24  
<TS 2232 A
106 69 11 VS6 0.94  
<TS 2233 A
106 69 12 VS4  
-1.19  
<TS 2234 A
106 95 12 DBH  
-1.69  
<TS 2235 A
106 101 17 04H 0.91  
<TS 2236 A
106 101 9
06C 0.09  
<TS 2237 A
106 111 15 DBC 1.6  
<TS 2238 A
106 117 14 VS2  
-0.26  
<TS 2239 A
106 117 17 06C  
-0.92  
<TS 2240 A
106 117 8
04H 0.64  
<TS 2241 A
106 119 14 VS4 1.03  
<TS 2242 A
106 119 9
04C  
-0.88  
<TS 2243 A
106 119 8
VS4  
-1.09  
<TS 2244 A
106 121 17 04C 0.88  
<TS 2245 A
106 121 9
04C 0.13  
<TS 2246 A
106 121 15 05C 0.11  
<TS 2247 A
106 125 9
06C 0.86  
<TS 2248 A
106 131 11 04H  
-0.88  
<TS 2249 A
106 131 20 03C  
-0.53  
<TS 2250 A
106 133 20 DBC 1.64  
<TS 2251 A
106 133 12 03C 0.85  
<TS 2252 A
106 135 9
01H 0.08  
<TS 2253 A
106 135 24 VS4  
-0.81  
<TS 2254 A
106 135 13 03C  
-0.83  
<TS 2255 A
107 32 13 03C 0.98  
<TS 2256 A
107 32 13 04C  
-0.24  
<TS 2257 A
107 32 5
04C  
-1  
<TS 2258 A
107 32 11 VS4  
-0.29  
<TS 2259 A
107 32 33 VS4  
-0.8  
<TS 2260 A
107 34 9
VS4 0.88  
<TS 2261 A
107 34 10 01H 0.86  
<TS 2262 A
107 36 10 03C 0.84  
<TS 74 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Percent No   SG     Row   Column     in Depth Location Elevation TS 2263   A       107       40           9     VS2       -0.92   <TS 2264   A       107       44         13     05H       -0.95   <TS 2265   A       107       44         14     05H       -0.17   <TS 2266   A       107       44         13     VS2       0.79   <TS 2267   A       107       44           8     VS4       0.88   <TS 2268   A       107       62         13     VS4       0.77   <TS 2269   A       107       84         11     05C       -0.87   <TS 2270   A       107       92         14     05C       0.83   <TS 2271   A       107       94         10     04C       -0.94   <TS 2272   A       107       98           9     04C       -0.11   <TS 2273   A       107       98           8     03C       -0.07   <TS 2274   A       107     114           9     03C       0.11   <TS 2275   A       107     118         10     04C       -0.92   <TS 2276   A       107     120         13     DBH       1.89   <TS 2277   A       107     122         11       03C       -0.15   <TS 2278   A       107     124         15       03C       -0.9   <TS 2279   A       107     124           9     VS2       -0.84   <TS 2280   A       107     124         15     VS2       -0.09   <TS 2281   A       107     124         11     VS2       0.66   <TS 2282   A       107     128         15     04C       -1.01   <TS 2283   A       107     130         21       VS2       -0.72   <TS 2284   A       107     130         11     VS2       0.9   <TS 2285   A       107     130         11     03C       -0.88   <TS 2286   A       107     134         17     03H       0.82   <TS 2287   A       107     134         24       VS4       -0.99   <TS 2288   A       107     134         17       VS4       0.79   <TS 2289   A       107     134         24       02C       -0.94   <TS 2290   A       107     134         11       03C       -0.95   <TS 2291   A       108       33         24       VS4       0.95   <TS 2292   A       108       33         29       VS4       -0.88   <TS 2293   A       108       35         12       VS4       -0.95   <TS 2294   A       108       35         10     VS4       0.91   <TS 2295   A       108       35         18     01C       0.86   <TS 2296   A       108       35         27       01C       0.09   <TS 2297   A       108       39           9     04H       0.95   <TS 2298   A       108       41         16       VS4       0.95   <TS 2299   A       108       63         20       VS2       0.83   <TS 2300   A       108       63         11       VS2       0.2   <TS 2301   A       108       65         18     DBH       1.93   <TS 75 of 156
Percent No SG Row Column in Depth Location Elevation TS 2263 A
107 40 9
VS2  
-0.92  
<TS 2264 A
107 44 13 05H  
-0.95  
<TS 2265 A
107 44 14 05H  
-0.17  
<TS 2266 A
107 44 13 VS2 0.79  
<TS 2267 A
107 44 8
VS4 0.88  
<TS 2268 A
107 62 13 VS4 0.77  
<TS 2269 A
107 84 11 05C  
-0.87  
<TS 2270 A
107 92 14 05C 0.83  
<TS 2271 A
107 94 10 04C  
-0.94  
<TS 2272 A
107 98 9
04C  
-0.11  
<TS 2273 A
107 98 8
03C  
-0.07  
<TS 2274 A
107 114 9
03C 0.11  
<TS 2275 A
107 118 10 04C  
-0.92  
<TS 2276 A
107 120 13 DBH 1.89  
<TS 2277 A
107 122 11 03C  
-0.15  
<TS 2278 A
107 124 15 03C  
-0.9  
<TS 2279 A
107 124 9
VS2  
-0.84  
<TS 2280 A
107 124 15 VS2  
-0.09  
<TS 2281 A
107 124 11 VS2 0.66  
<TS 2282 A
107 128 15 04C  
-1.01  
<TS 2283 A
107 130 21 VS2  
-0.72  
<TS 2284 A
107 130 11 VS2 0.9  
<TS 2285 A
107 130 11 03C  
-0.88  
<TS 2286 A
107 134 17 03H 0.82  
<TS 2287 A
107 134 24 VS4  
-0.99  
<TS 2288 A
107 134 17 VS4 0.79  
<TS 2289 A
107 134 24 02C  
-0.94  
<TS 2290 A
107 134 11 03C  
-0.95  
<TS 2291 A
108 33 24 VS4 0.95  
<TS 2292 A
108 33 29 VS4  
-0.88  
<TS 2293 A
108 35 12 VS4  
-0.95  
<TS 2294 A
108 35 10 VS4 0.91  
<TS 2295 A
108 35 18 01C 0.86  
<TS 2296 A
108 35 27 01C 0.09  
<TS 2297 A
108 39 9
04H 0.95  
<TS 2298 A
108 41 16 VS4 0.95  
<TS 2299 A
108 63 20 VS2 0.83  
<TS 2300 A
108 63 11 VS2 0.2  
<TS 2301 A
108 65 18 DBH 1.93  
<TS 75 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2302   A       108     67         10       06C       -0.99   <TS 2303   A       108     69         13       07C       0.83   <TS 2304   A       108     87         11       05C       0.84   <TS 2305   A       108     89         12       06C       -0.94   <TS 2306   A       108     93         13       06C       0.37   <TS 2307   A       108     95         11       03C       0.84   <TS 2308   A       108     99         10       DBH       1.96   <TS 2309   A       108     115         15       05H       0.95   <TS 2310   A       108     117         17       05C       0.85   <TS 2311   A       108     119         12       03C       0.44   <TS 2312   A       108     123         16       VS2       -0.96   <TS 2313   A       108     131         14       02C       -0.87   <TS 2314   A       108     133         12       04C       0.82   <TS 2315   A       108     133         16       04C       -0.9   <TS 2316   A       109     34           9       01C       0.86   <TS 2317   A       109     34         31       VS4       0.64   <TS 2318   A       109     34         10       VS4       -0.91   <TS 2319   A       109     34         12       05H       -0.82   <TS 2320   A       109     34         12       04H       -0.91   <TS 2321   A       109     34         10       01H       0.94   <TS 2322   A       109     42           8       03H       0.92   <TS 2323   A       109     62         15       06C       0.89   <TS 2324   A       109     90         10       07C       -0.88   <TS 2325   A       109     90         11       07C       -0.09   <TS 2326   A       109     98         30       VS2       -0.79   <TS 2327   A       109     114         19       06C       0.83   <TS 2328   A       109     114         12       03C       0.99   <TS 2329   A       109     116         11       04H       -0.89   <TS 2330   A       109     118         15       04C       -0.94   <TS 2331   A       109     120         21       03C       -0.13   <TS 2332   A       109     124         9       02C       0.85   <TS 2333   A       109     124         11       08C       -1.12   <TS 2334   A       109     128         10       04C       0.87   <TS 2335   A       109     132         20       04C       0.85   <TS 2336   A       110     35         10       VS4         0.9   <TS 2337   A       110     35         15       01H       0.92   <TS 2338   A       110     39         15       VS2       0.86   <TS 2339   A       110     47         11       05C         0.9   <TS 2340   A       110     79         11       06C       -0.18   <TS 76 of 156
Percent No SG Row Column in Depth Location Elevation TS 2302 A
108 67 10 06C  
-0.99  
<TS 2303 A
108 69 13 07C 0.83  
<TS 2304 A
108 87 11 05C 0.84  
<TS 2305 A
108 89 12 06C  
-0.94  
<TS 2306 A
108 93 13 06C 0.37  
<TS 2307 A
108 95 11 03C 0.84  
<TS 2308 A
108 99 10 DBH 1.96  
<TS 2309 A
108 115 15 05H 0.95  
<TS 2310 A
108 117 17 05C 0.85  
<TS 2311 A
108 119 12 03C 0.44  
<TS 2312 A
108 123 16 VS2  
-0.96  
<TS 2313 A
108 131 14 02C  
-0.87  
<TS 2314 A
108 133 12 04C 0.82  
<TS 2315 A
108 133 16 04C  
-0.9  
<TS 2316 A
109 34 9
01C 0.86  
<TS 2317 A
109 34 31 VS4 0.64  
<TS 2318 A
109 34 10 VS4  
-0.91  
<TS 2319 A
109 34 12 05H  
-0.82  
<TS 2320 A
109 34 12 04H  
-0.91  
<TS 2321 A
109 34 10 01H 0.94  
<TS 2322 A
109 42 8
03H 0.92  
<TS 2323 A
109 62 15 06C 0.89  
<TS 2324 A
109 90 10 07C  
-0.88  
<TS 2325 A
109 90 11 07C  
-0.09  
<TS 2326 A
109 98 30 VS2  
-0.79  
<TS 2327 A
109 114 19 06C 0.83  
<TS 2328 A
109 114 12 03C 0.99  
<TS 2329 A
109 116 11 04H  
-0.89  
<TS 2330 A
109 118 15 04C  
-0.94  
<TS 2331 A
109 120 21 03C  
-0.13  
<TS 2332 A
109 124 9
02C 0.85  
<TS 2333 A
109 124 11 08C  
-1.12  
<TS 2334 A
109 128 10 04C 0.87  
<TS 2335 A
109 132 20 04C 0.85  
<TS 2336 A
110 35 10 VS4 0.9  
<TS 2337 A
110 35 15 01H 0.92  
<TS 2338 A
110 39 15 VS2 0.86  
<TS 2339 A
110 47 11 05C 0.9  
<TS 2340 A
110 79 11 06C  
-0.18  
<TS 76 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2341   A       110       83         16       06C         0.9   <TS 2342   A       110       91         13       04C       -0.9   <TS 2343   A       110     109         7       DBC       -0.24   <TS 2344   A       110     109         15       05C       1.16   <TS 2345   A       110     109         10       04C         0.9   <TS 2346   A       110     115         12       08H       0.92   <TS 2347   A       110     115         9       04C         0.9   <TS 2348   A       110     123         21       08H       -1.05   <TS 2349   A       110     125         22       VS2         0.9   <TS 2350   A       110     131         15       01H       0.11   <TS 2351   A       110     131         31       DBH       -1.73   <TS 2352   A       110     131         15       04C       -0.9   <TS 2353   A       110     131         19       03C       0.81   <TS 2354   A       110     131         11       05C       -0.02   <TS 2355   A       111       44         16       06C       -0.15   <TS 2356   A       111       50         9       04H       -0.87   <TS 2357   A       111       62         19       VS2       -0.82   <TS 2358   A       111       82         8       02H       0.85   <TS 2359   A       111       86         11       02C         0.9   <TS 2360   A       111     100         11       05C       0.85   <TS 2361   A       111     104         11       04C       -0.18   <TS 2362   A       111     110         17       VS4       -0.9   <TS 2363   A       111     116         14       03C       0.83   <TS 2364   A       111     116         13       03H       0.91   <TS 2365   A       111     126         14       04C       0.85   <TS 2366   A       111     126         8       04C       0.13   <TS 2367   A       111     128         11       VS4       0.96   <TS 2368   A       111     128         12       03C       0.86   <TS 2369   A       111     128         20       03C       -0.87   <TS 2370   A       111     130         19       04C       -0.2   <TS 2371   A       111     130         12       03H       -0.92   <TS 2372   A       112       37         10       DBH       -1.52   <TS 2373   A       112       37         20       02C       -0.92   <TS 2374   A       112       39         9       VS6       0.93   <TS 2375   A       112       41         12       VS6       -0.86   <TS 2376   A       112       41         20       VS4       -0.95   <TS 2377   A       112       59         21       VS4       -0.79   <TS 2378   A       112       59         24       VS4       0.02   <TS 2379   A       112       59         33       VS6       0.94   <TS 77 of 156
Percent No SG Row Column in Depth Location Elevation TS 2341 A
110 83 16 06C 0.9  
<TS 2342 A
110 91 13 04C  
-0.9  
<TS 2343 A
110 109 7
DBC  
-0.24  
<TS 2344 A
110 109 15 05C 1.16  
<TS 2345 A
110 109 10 04C 0.9  
<TS 2346 A
110 115 12 08H 0.92  
<TS 2347 A
110 115 9
04C 0.9  
<TS 2348 A
110 123 21 08H  
-1.05  
<TS 2349 A
110 125 22 VS2 0.9  
<TS 2350 A
110 131 15 01H 0.11  
<TS 2351 A
110 131 31 DBH  
-1.73  
<TS 2352 A
110 131 15 04C  
-0.9  
<TS 2353 A
110 131 19 03C 0.81  
<TS 2354 A
110 131 11 05C  
-0.02  
<TS 2355 A
111 44 16 06C  
-0.15  
<TS 2356 A
111 50 9
04H  
-0.87  
<TS 2357 A
111 62 19 VS2  
-0.82  
<TS 2358 A
111 82 8
02H 0.85  
<TS 2359 A
111 86 11 02C 0.9  
<TS 2360 A
111 100 11 05C 0.85  
<TS 2361 A
111 104 11 04C  
-0.18  
<TS 2362 A
111 110 17 VS4  
-0.9  
<TS 2363 A
111 116 14 03C 0.83  
<TS 2364 A
111 116 13 03H 0.91  
<TS 2365 A
111 126 14 04C 0.85  
<TS 2366 A
111 126 8
04C 0.13  
<TS 2367 A
111 128 11 VS4 0.96  
<TS 2368 A
111 128 12 03C 0.86  
<TS 2369 A
111 128 20 03C  
-0.87  
<TS 2370 A
111 130 19 04C  
-0.2  
<TS 2371 A
111 130 12 03H  
-0.92  
<TS 2372 A
112 37 10 DBH  
-1.52  
<TS 2373 A
112 37 20 02C  
-0.92  
<TS 2374 A
112 39 9
VS6 0.93  
<TS 2375 A
112 41 12 VS6  
-0.86  
<TS 2376 A
112 41 20 VS4  
-0.95  
<TS 2377 A
112 59 21 VS4  
-0.79  
<TS 2378 A
112 59 24 VS4 0.02  
<TS 2379 A
112 59 33 VS6 0.94  
<TS 77 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2380   A       112     65         12       VS4       0.74   <TS 2381   A       112     65         14       VS4       -0.79   <TS 2382   A       112     69         12       VS2       0.81   <TS 2383   A       112       69       16       VS2       -0.02   <TS 2384   A       112       89       10       04C       -0.9   <TS 2385   A       112     89         15       VS4       -0.87   <TS 2386   A       112     103       12       VS2         0.9   <TS 2387   A       112     103       12       04H       0.89   <TS 2388   A       112     103       14       VS2       -0.92   <TS 2389   A       112     115       13       04C       -0.89   <TS 2390   A       112     119       14       04H       0.92   <TS 2391   A       112     121       17       VS2       -0.81   <TS 2392   A       112     125       11       05C       -0.89   <TS 2393   A       112     125       12       04C       0.89   <TS 2394   A       112     127       16       05C       -0.96   <TS 2395   A       113       36       11       01H         0.9   <TS 2396   A       113       36         9       01H       -0.09   <TS 2397   A       113     36         18       VS4       -0.79   <TS 2398   A       113       38       14       02C       0.86   <TS 2399   A       113       38       12       01C       -0.95   <TS 2400   A       113     42         14       VS4       0.95   <TS 2401   A       113     42         15       VS4       -0.88   <TS 2402   A       113     64         12       07H       0.83   <TS 2403   A       113     68         15       VS2       -0.77   <TS 2404   A       113     68         13       VS6       1.05   <TS 2405   A       113     68         11       VS4       -1.05   <TS 2406   A       113     76         16       VS6       0.85   <TS 2407   A       113     90         14       03C       -0.92   <TS 2408   A       113     90         10       VS6       -0.74   <TS 2409   A       113     90         12       VS4       -0.59   <TS 2410   A       113     118       15       04C       0.13   <TS 2411   A       113     128       12       03H       0.94   <TS 2412   A       113     128       17       04H       -0.87   <TS 2413   A       113     130       22       VS4       -0.83   <TS 2414   A       113     130       22       VS4       -0.48   <TS 2415   A       114     45         8       VS2       0.53   <TS 2416   A       114     47         11       05H       0.91   <TS 2417   A       114     51         11       04C       0.88   <TS 2418   A       114       53         9       04H       0.91   <TS 78 of 156
Percent No SG Row Column in Depth Location Elevation TS 2380 A
112 65 12 VS4 0.74  
<TS 2381 A
112 65 14 VS4  
-0.79  
<TS 2382 A
112 69 12 VS2 0.81  
<TS 2383 A
112 69 16 VS2  
-0.02  
<TS 2384 A
112 89 10 04C  
-0.9  
<TS 2385 A
112 89 15 VS4  
-0.87  
<TS 2386 A
112 103 12 VS2 0.9  
<TS 2387 A
112 103 12 04H 0.89  
<TS 2388 A
112 103 14 VS2  
-0.92  
<TS 2389 A
112 115 13 04C  
-0.89  
<TS 2390 A
112 119 14 04H 0.92  
<TS 2391 A
112 121 17 VS2  
-0.81  
<TS 2392 A
112 125 11 05C  
-0.89  
<TS 2393 A
112 125 12 04C 0.89  
<TS 2394 A
112 127 16 05C  
-0.96  
<TS 2395 A
113 36 11 01H 0.9  
<TS 2396 A
113 36 9
01H  
-0.09  
<TS 2397 A
113 36 18 VS4  
-0.79  
<TS 2398 A
113 38 14 02C 0.86  
<TS 2399 A
113 38 12 01C  
-0.95  
<TS 2400 A
113 42 14 VS4 0.95  
<TS 2401 A
113 42 15 VS4  
-0.88  
<TS 2402 A
113 64 12 07H 0.83  
<TS 2403 A
113 68 15 VS2  
-0.77  
<TS 2404 A
113 68 13 VS6 1.05  
<TS 2405 A
113 68 11 VS4  
-1.05  
<TS 2406 A
113 76 16 VS6 0.85  
<TS 2407 A
113 90 14 03C  
-0.92  
<TS 2408 A
113 90 10 VS6  
-0.74  
<TS 2409 A
113 90 12 VS4  
-0.59  
<TS 2410 A
113 118 15 04C 0.13  
<TS 2411 A
113 128 12 03H 0.94  
<TS 2412 A
113 128 17 04H  
-0.87  
<TS 2413 A
113 130 22 VS4  
-0.83  
<TS 2414 A
113 130 22 VS4  
-0.48  
<TS 2415 A
114 45 8
VS2 0.53  
<TS 2416 A
114 47 11 05H 0.91  
<TS 2417 A
114 51 11 04C 0.88  
<TS 2418 A
114 53 9
04H 0.91  
<TS 78 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2419   A       114       53         9       04C       0.95   <TS 2420   A       114       65         14       VS4       0.83   <TS 2421   A       114       75         11       06H       0.97   <TS 2422   A       114       79         8       05H       0.91   <TS 2423   A       114     119         14       07C       0.76   <TS 2424   A       114     119         16       03C       0.76   <TS 2425   A       114     121         14       04C       0.81   <TS 2426   A       114     121         11       03C       -0.91   <TS 2427   A       114     123         12       04C       -0.94   <TS 2428   A       114     123         20       03C       -0.89   <TS 2429   A       114     129         8       03H       1.01   <TS 2430   A       114     129         12       08H       -0.97   <TS 2431   A       114     129         25       VS4       -0.91   <TS 2432   A       114     129         10       VS4       0.97   <TS 2433   A       115       38         15       02C       0.09   <TS 2434   A       115       38         10       02C       -0.86   <TS 2435   A       115       38         12       DBC       1.31   <TS 2436   A       115       38         11       VS4       0.51   <TS 2437   A       115       38         10       VS4       0.89   <TS 2438   A       115       46         16       VS4       -0.88   <TS 2439   A       115       50         10       VS4       -0.77   <TS 2440   A       115       78         17       06H       -0.87   <TS 2441   A       115       82         13       05H       0.82   <TS 2442   A       115       82         8       05H       -0.04   <TS 2443   A       115       90         9       VS2       -0.79   <TS 2444   A       115       90         39       VS4       -0.88   <TS 2445   A       115       92         27       VS1       0.79   <TS 2446   A       115     124         12       05C       1.01   <TS 2447   A       115     124         17       04C       -0.95   <TS 2448   A       115     124         10       03C       0.88   <TS 2449   A       115     128         11       05H         0.8   <TS 2450   A       115     128         9       VS4       -0.64   <TS 2451   A       116       39         30       02C       -0.86   <TS 2452   A       116       39         13       01C       -0.49   <TS 2453   A       116       39         15       VS6       -0.57   <TS 2454   A       116       45         12       VS7       0.75   <TS 2455   A       116       45         15       02H       0.82   <TS 2456   A       116       51         11       05H       -0.19   <TS 2457   A       116       51         17       07H       0.88   <TS 79 of 156
Percent No SG Row Column in Depth Location Elevation TS 2419 A
114 53 9
04C 0.95  
<TS 2420 A
114 65 14 VS4 0.83  
<TS 2421 A
114 75 11 06H 0.97  
<TS 2422 A
114 79 8
05H 0.91  
<TS 2423 A
114 119 14 07C 0.76  
<TS 2424 A
114 119 16 03C 0.76  
<TS 2425 A
114 121 14 04C 0.81  
<TS 2426 A
114 121 11 03C  
-0.91  
<TS 2427 A
114 123 12 04C  
-0.94  
<TS 2428 A
114 123 20 03C  
-0.89  
<TS 2429 A
114 129 8
03H 1.01  
<TS 2430 A
114 129 12 08H  
-0.97  
<TS 2431 A
114 129 25 VS4  
-0.91  
<TS 2432 A
114 129 10 VS4 0.97  
<TS 2433 A
115 38 15 02C 0.09  
<TS 2434 A
115 38 10 02C  
-0.86  
<TS 2435 A
115 38 12 DBC 1.31  
<TS 2436 A
115 38 11 VS4 0.51  
<TS 2437 A
115 38 10 VS4 0.89  
<TS 2438 A
115 46 16 VS4  
-0.88  
<TS 2439 A
115 50 10 VS4  
-0.77  
<TS 2440 A
115 78 17 06H  
-0.87  
<TS 2441 A
115 82 13 05H 0.82  
<TS 2442 A
115 82 8
05H  
-0.04  
<TS 2443 A
115 90 9
VS2  
-0.79  
<TS 2444 A
115 90 39 VS4  
-0.88  
<TS 2445 A
115 92 27 VS1 0.79  
<TS 2446 A
115 124 12 05C 1.01  
<TS 2447 A
115 124 17 04C  
-0.95  
<TS 2448 A
115 124 10 03C 0.88  
<TS 2449 A
115 128 11 05H 0.8  
<TS 2450 A
115 128 9
VS4  
-0.64  
<TS 2451 A
116 39 30 02C  
-0.86  
<TS 2452 A
116 39 13 01C  
-0.49  
<TS 2453 A
116 39 15 VS6  
-0.57  
<TS 2454 A
116 45 12 VS7 0.75  
<TS 2455 A
116 45 15 02H 0.82  
<TS 2456 A
116 51 11 05H  
-0.19  
<TS 2457 A
116 51 17 07H 0.88  
<TS 79 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2458   A       116       53         12       05C         0.9   <TS 2459   A       116       55         12       05H       -0.82   <TS 2460   A       116       61         11       VS4       0.83   <TS 2461   A       116       63         14       VS6       -0.79   <TS 2462   A       116       71         11       VS4       0.94   <TS 2463   A       116       81         12       05H       0.89   <TS 2464   A       116       81         14       VS6       -0.85   <TS 2465   A       116       81         10       06C       0.87   <TS 2466   A       116       81         11       06C       -0.92   <TS 2467   A       116       95         13       07C       -0.92   <TS 2468   A       116       95         10       06C       0.81   <TS 2469   A       116     105         23       VS4       -1.05   <TS 2470   A       116     111         15       05C       0.04   <TS 2471   A       116     119         21       03C       0.81   <TS 2472   A       116     121         11       03C       -0.88   <TS 2473   A       116     121         22       04C       0.82   <TS 2474   A       116     121         12       VS7       0.96   <TS 2475   A       116     121         7       04C       -0.09   <TS 2476   A       116     123         15       06C       0.04   <TS 2477   A       117     40         21       VS4       -0.95   <TS 2478   A       117     40         24       02C       0.88   <TS 2479   A       117     40         10       02C       -0.15   <TS 2480   A       117     42         36       01C       -0.93   <TS 2481   A       117     42         12       02C       0.81   <TS 2482   A       117     44         10       02C       0.86   <TS 2483   A       117       50         12       VS4       -0.88   <TS 2484   A       117       58         15       06C       0.83   <TS 2485   A       117       70         11       06C       0.75   <TS 2486   A       117       72         11       07H       0.46   <TS 2487   A       117       76         10       07H       0.13   <TS 2488   A       117       78         11       04H       0.88   <TS 2489   A       117     82         13       05H       -0.97   <TS 2490   A       117     90         12       VS2       0.83   <TS 2491   A       117     94           9       03C       0.88   <TS 2492   A       117     110         13       03C       0.86   <TS 2493   A       117     114         14       03C       -0.88   <TS 2494   A       117     120         12       03H       0.84   <TS 2495   A       117     120         13       02C       0.83   <TS 2496   A       117     122         14       VS4       -0.02   <TS 80 of 156
Percent No SG Row Column in Depth Location Elevation TS 2458 A
116 53 12 05C 0.9  
<TS 2459 A
116 55 12 05H  
-0.82  
<TS 2460 A
116 61 11 VS4 0.83  
<TS 2461 A
116 63 14 VS6  
-0.79  
<TS 2462 A
116 71 11 VS4 0.94  
<TS 2463 A
116 81 12 05H 0.89  
<TS 2464 A
116 81 14 VS6  
-0.85  
<TS 2465 A
116 81 10 06C 0.87  
<TS 2466 A
116 81 11 06C  
-0.92  
<TS 2467 A
116 95 13 07C  
-0.92  
<TS 2468 A
116 95 10 06C 0.81  
<TS 2469 A
116 105 23 VS4  
-1.05  
<TS 2470 A
116 111 15 05C 0.04  
<TS 2471 A
116 119 21 03C 0.81  
<TS 2472 A
116 121 11 03C  
-0.88  
<TS 2473 A
116 121 22 04C 0.82  
<TS 2474 A
116 121 12 VS7 0.96  
<TS 2475 A
116 121 7
04C  
-0.09  
<TS 2476 A
116 123 15 06C 0.04  
<TS 2477 A
117 40 21 VS4  
-0.95  
<TS 2478 A
117 40 24 02C 0.88  
<TS 2479 A
117 40 10 02C  
-0.15  
<TS 2480 A
117 42 36 01C  
-0.93  
<TS 2481 A
117 42 12 02C 0.81  
<TS 2482 A
117 44 10 02C 0.86  
<TS 2483 A
117 50 12 VS4  
-0.88  
<TS 2484 A
117 58 15 06C 0.83  
<TS 2485 A
117 70 11 06C 0.75  
<TS 2486 A
117 72 11 07H 0.46  
<TS 2487 A
117 76 10 07H 0.13  
<TS 2488 A
117 78 11 04H 0.88  
<TS 2489 A
117 82 13 05H  
-0.97  
<TS 2490 A
117 90 12 VS2 0.83  
<TS 2491 A
117 94 9
03C 0.88  
<TS 2492 A
117 110 13 03C 0.86  
<TS 2493 A
117 114 14 03C  
-0.88  
<TS 2494 A
117 120 12 03H 0.84  
<TS 2495 A
117 120 13 02C 0.83  
<TS 2496 A
117 122 14 VS4  
-0.02  
<TS 80 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2497   A       117     122       12       04C       -0.2   <TS 2498   A       118     41         9       01H       0.89   <TS 2499   A       118     41         16       VS4       -0.92   <TS 2500   A       118     41         26       02C         0   <TS 2501   A       118     43         35       01C       -0.91   <TS 2502   A       118     43         11       02C       -0.94   <TS 2503   A       118     43         8       02C       0.77   <TS 2504   A       118     43         10       06H       -0.91   <TS 2505   A       118     43         12       03H       0.88   <TS 2506   A       118     45         10       VS6       0.99   <TS 2507   A       118     47         14       02H       0.73   <TS 2508   A       118       51       13       06C       0.84   <TS 2509   A       118       53       10       VS6       -0.86   <TS 2510   A       118       63       16       VS4       -0.94   <TS 2511   A       118       63         9       VS4       0.92   <TS 2512   A       118       97       13       VS2       -0.99   <TS 2513   A       118       99       17       VS2       0.83   <TS 2514   A       118     101       11       04H       -0.13   <TS 2515   A       118     101       12       VS4       0.88   <TS 2516   A       118     105       15       04C       0.88   <TS 2517   A       118     125       21       VS7       -0.72   <TS 2518   A       119       42       12       VS4       -0.88   <TS 2519   A       119       44       11       02H         0.9   <TS 2520   A       119       52       26       06C       0.84   <TS 2521   A       119       60       15       VS4       -0.88   <TS 2522   A       119       60       15       VS4       0.93   <TS 2523   A       119       76         9       06C       0.83   <TS 2524   A       119     82         11       VS4       0.18   <TS 2525   A       119     98         6       07H         0.9   <TS 2526   A       119     110       21       04C       -0.86   <TS 2527   A       119     122       15       06H       0.92   <TS 2528   A       119     122       13       03C       0.77   <TS 2529   A       119     124       10       VS4       -0.86   <TS 2530   A       119     124         7       VS4       0.61   <TS 2531   A       120       45       11       02H       0.88   <TS 2532   A       120       75       12       VS4       0.98   <TS 2533   A       120       75       14       08C       -0.94   <TS 2534   A       120       77         8       07C       0.09   <TS 2535   A       120       81       10       VS4       1.07   <TS 81 of 156
Percent No SG Row Column in Depth Location Elevation TS 2497 A
117 122 12 04C  
-0.2  
<TS 2498 A
118 41 9
01H 0.89  
<TS 2499 A
118 41 16 VS4  
-0.92  
<TS 2500 A
118 41 26 02C 0  
<TS 2501 A
118 43 35 01C  
-0.91  
<TS 2502 A
118 43 11 02C  
-0.94  
<TS 2503 A
118 43 8
02C 0.77  
<TS 2504 A
118 43 10 06H  
-0.91  
<TS 2505 A
118 43 12 03H 0.88  
<TS 2506 A
118 45 10 VS6 0.99  
<TS 2507 A
118 47 14 02H 0.73  
<TS 2508 A
118 51 13 06C 0.84  
<TS 2509 A
118 53 10 VS6  
-0.86  
<TS 2510 A
118 63 16 VS4  
-0.94  
<TS 2511 A
118 63 9
VS4 0.92  
<TS 2512 A
118 97 13 VS2  
-0.99  
<TS 2513 A
118 99 17 VS2 0.83  
<TS 2514 A
118 101 11 04H  
-0.13  
<TS 2515 A
118 101 12 VS4 0.88  
<TS 2516 A
118 105 15 04C 0.88  
<TS 2517 A
118 125 21 VS7  
-0.72  
<TS 2518 A
119 42 12 VS4  
-0.88  
<TS 2519 A
119 44 11 02H 0.9  
<TS 2520 A
119 52 26 06C 0.84  
<TS 2521 A
119 60 15 VS4  
-0.88  
<TS 2522 A
119 60 15 VS4 0.93  
<TS 2523 A
119 76 9
06C 0.83  
<TS 2524 A
119 82 11 VS4 0.18  
<TS 2525 A
119 98 6
07H 0.9  
<TS 2526 A
119 110 21 04C  
-0.86  
<TS 2527 A
119 122 15 06H 0.92  
<TS 2528 A
119 122 13 03C 0.77  
<TS 2529 A
119 124 10 VS4  
-0.86  
<TS 2530 A
119 124 7
VS4 0.61  
<TS 2531 A
120 45 11 02H 0.88  
<TS 2532 A
120 75 12 VS4 0.98  
<TS 2533 A
120 75 14 08C  
-0.94  
<TS 2534 A
120 77 8
07C 0.09  
<TS 2535 A
120 81 10 VS4 1.07  
<TS 81 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2536   A       120       81         18       07C       0.85   <TS 2537   A       120       81         17       07C       0.07   <TS 2538   A       120       81         13       06C       0.83   <TS 2539   A       120       89         14       06C       -0.88   <TS 2540   A       120       93         14       06C       0.81   <TS 2541   A       120     111         12       04C       0.07   <TS 2542   A       120     111         11       03C       -0.94   <TS 2543   A       120     115         14       04C       0.83   <TS 2544   A       120     115         14       05C       -0.89   <TS 2545   A       120     117         9       04C       0.75   <TS 2546   A       120     119         20       03C       0.83   <TS 2547   A       120     121         21       05C       0.81   <TS 2548   A       120     123         18       01H       -0.13   <TS 2549   A       121       44         18       VS4       -0.02   <TS 2550   A       121       44         9       VS4       0.66   <TS 2551   A       121       44         16       01C       -0.95   <TS 2552   A       121       44         10       VS7       0.9   <TS 2553   A       121       50         14       06C       0.79   <TS 2554   A       121       64         11       07H       0.86   <TS 2555   A       121       76         12       VS6       0.83   <TS 2556   A       121       88         13       07C       -0.92   <TS 2557   A       121     104         9       VS4       0.61   <TS 2558   A       121     104         11       VS6       -0.85   <TS 2559   A       121     104         11       VS6       -0.07   <TS 2560   A       121     106         8       02C       0.83   <TS 2561   A       121     112         22       VS7       -0.73   <TS 2562   A       121     116         15       04C       -0.88   <TS 2563   A       121     116         23       03C       0.84   <TS 2564   A       121     118         29       VS4       -0.73   <TS 2565   A       121     118         16       VS4       0.04   <TS 2566   A       121     118         19       VS4       0.77   <TS 2567   A       121     118         9       VS6       0.94   <TS 2568   A       121     118         8       VS7       -1.05   <TS 2569   A       121     118         25       03C       0.92   <TS 2570   A       121     120         14       05H       0.82   <TS 2571   A       121     120         15       06H       0.85   <TS 2572   A       122       45         11       01C       0.91   <TS 2573   A       122       53         12       06H       0.77   <TS 2574   A       122       63         15       05H       0.95   <TS 82 of 156
Percent No SG Row Column in Depth Location Elevation TS 2536 A
120 81 18 07C 0.85  
<TS 2537 A
120 81 17 07C 0.07  
<TS 2538 A
120 81 13 06C 0.83  
<TS 2539 A
120 89 14 06C  
-0.88  
<TS 2540 A
120 93 14 06C 0.81  
<TS 2541 A
120 111 12 04C 0.07  
<TS 2542 A
120 111 11 03C  
-0.94  
<TS 2543 A
120 115 14 04C 0.83  
<TS 2544 A
120 115 14 05C  
-0.89  
<TS 2545 A
120 117 9
04C 0.75  
<TS 2546 A
120 119 20 03C 0.83  
<TS 2547 A
120 121 21 05C 0.81  
<TS 2548 A
120 123 18 01H  
-0.13  
<TS 2549 A
121 44 18 VS4  
-0.02  
<TS 2550 A
121 44 9
VS4 0.66  
<TS 2551 A
121 44 16 01C  
-0.95  
<TS 2552 A
121 44 10 VS7 0.9  
<TS 2553 A
121 50 14 06C 0.79  
<TS 2554 A
121 64 11 07H 0.86  
<TS 2555 A
121 76 12 VS6 0.83  
<TS 2556 A
121 88 13 07C  
-0.92  
<TS 2557 A
121 104 9
VS4 0.61  
<TS 2558 A
121 104 11 VS6  
-0.85  
<TS 2559 A
121 104 11 VS6  
-0.07  
<TS 2560 A
121 106 8
02C 0.83  
<TS 2561 A
121 112 22 VS7  
-0.73  
<TS 2562 A
121 116 15 04C  
-0.88  
<TS 2563 A
121 116 23 03C 0.84  
<TS 2564 A
121 118 29 VS4  
-0.73  
<TS 2565 A
121 118 16 VS4 0.04  
<TS 2566 A
121 118 19 VS4 0.77  
<TS 2567 A
121 118 9
VS6 0.94  
<TS 2568 A
121 118 8
VS7  
-1.05  
<TS 2569 A
121 118 25 03C 0.92  
<TS 2570 A
121 120 14 05H 0.82  
<TS 2571 A
121 120 15 06H 0.85  
<TS 2572 A
122 45 11 01C 0.91  
<TS 2573 A
122 53 12 06H 0.77  
<TS 2574 A
122 63 15 05H 0.95  
<TS 82 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2575   A       122       63         10       05H         0   <TS 2576   A       122       65         9       DBH       1.49   <TS 2577   A       122       65         12       VS6       0.83   <TS 2578   A       122       81         20       VS4         1.1   <TS 2579   A       122     105         8       04C       0.88   <TS 2580   A       122     105         9       04C       0.09   <TS 2581   A       122     111         14       05C       -1.01   <TS 2582   A       122     111         11       02C       -0.15   <TS 2583   A       122     117         10       VS2       0.02   <TS 2584   A       122     117         17       VS2       -0.83   <TS 2585   A       122     117         13       VS1       0.85   <TS 2586   A       123       48         9       05C       0.86   <TS 2587   A       123       52         11       06H       -0.91   <TS 2588   A       123     110         10       VS2       0.94   <TS 2589   A       123     110         7       06C       -0.07   <TS 2590   A       123     112         14       03C       0.9   <TS 2591   A       123     114         17       04C       -0.18   <TS 2592   A       123     120         15       02H       0.79   <TS 2593   A       123     120         9       04H       -0.84   <TS 2594   A       123     120         10       04H       0.88   <TS 2595   A       123     120         11       VS4       -0.79   <TS 2596   A       124       49         12       01H       0.91   <TS 2597   A       124       51         14       03H       0.86   <TS 2598   A       124       57         10       05C       0.9   <TS 2599   A       124     117         13       06C       -0.2   <TS 2600   A       124     117         13       03C         0   <TS 2601   A       124     119         9       02C       -0.9   <TS 2602   A       124     119         11       VS4       -0.9   <TS 2603   A       125       48         21       VS4       -0.93   <TS 2604   A       125       88         19       08H       0.89   <TS 2605   A       125     110         18       03C       0.83   <TS 2606   A       125     112         16       07H       -0.26   <TS 2607   A       125     112         16       VS6       -0.9   <TS 2608   A       125     112         11       04C       -0.92   <TS 2609   A       125     112         16       03C       0.13   <TS 2610   A       125     112         11       02C       0.88   <TS 2611   A       125     114         13       03H       -0.19   <TS 2612   A       125     114         11       02C       0.84   <TS 2613   A       125     118         12       VS4       -0.83   <TS 83 of 156
Percent No SG Row Column in Depth Location Elevation TS 2575 A
122 63 10 05H 0  
<TS 2576 A
122 65 9
DBH 1.49  
<TS 2577 A
122 65 12 VS6 0.83  
<TS 2578 A
122 81 20 VS4 1.1  
<TS 2579 A
122 105 8
04C 0.88  
<TS 2580 A
122 105 9
04C 0.09  
<TS 2581 A
122 111 14 05C  
-1.01  
<TS 2582 A
122 111 11 02C  
-0.15  
<TS 2583 A
122 117 10 VS2 0.02  
<TS 2584 A
122 117 17 VS2  
-0.83  
<TS 2585 A
122 117 13 VS1 0.85  
<TS 2586 A
123 48 9
05C 0.86  
<TS 2587 A
123 52 11 06H  
-0.91  
<TS 2588 A
123 110 10 VS2 0.94  
<TS 2589 A
123 110 7
06C  
-0.07  
<TS 2590 A
123 112 14 03C 0.9  
<TS 2591 A
123 114 17 04C  
-0.18  
<TS 2592 A
123 120 15 02H 0.79  
<TS 2593 A
123 120 9
04H  
-0.84  
<TS 2594 A
123 120 10 04H 0.88  
<TS 2595 A
123 120 11 VS4  
-0.79  
<TS 2596 A
124 49 12 01H 0.91  
<TS 2597 A
124 51 14 03H 0.86  
<TS 2598 A
124 57 10 05C 0.9  
<TS 2599 A
124 117 13 06C  
-0.2  
<TS 2600 A
124 117 13 03C 0  
<TS 2601 A
124 119 9
02C  
-0.9  
<TS 2602 A
124 119 11 VS4  
-0.9  
<TS 2603 A
125 48 21 VS4  
-0.93  
<TS 2604 A
125 88 19 08H 0.89  
<TS 2605 A
125 110 18 03C 0.83  
<TS 2606 A
125 112 16 07H  
-0.26  
<TS 2607 A
125 112 16 VS6  
-0.9  
<TS 2608 A
125 112 11 04C  
-0.92  
<TS 2609 A
125 112 16 03C 0.13  
<TS 2610 A
125 112 11 02C 0.88  
<TS 2611 A
125 114 13 03H  
-0.19  
<TS 2612 A
125 114 11 02C 0.84  
<TS 2613 A
125 118 12 VS4  
-0.83  
<TS 83 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*
Percent No   SG     Row   Column     in Depth Location Elevation TS 2614   A       126       51         10       01H       0.09   <TS 2615   A       126       51         20       03H       0.85   <TS 2616   A       126       51         9       VS2       0.86   <TS 2617   A       126       61         7       07H       -0.99   <TS 2618   A       126       63         11       07H       0.85   <TS 2619   A       126       69         14       VS4       -0.9   <TS 2620   A       126       69         34       VS4       0.88   <TS 2621   A       126       69         10     08H       -0.88   <TS 2622   A       126       73         12     08C       -0.9   <TS 2623   A       126       77         13       VS1       -0.89   <TS 2624   A       126       77         15       VS1       0.91   <TS 2625   A       126       83         10       07H       0.09   <TS 2626   A       126       85         12       06C       0.89   <TS 2627   A       126     103         10     VS1       0.92   <TS 2628   A       126     103         31       VS4       -0.99   <TS 2629   A       126     109         10       05C       0.79   <TS 2630   A       126     109         6       05C       0.07   <TS 2631   A       126     109         9       03C       0.9   <TS 2632   A       126     109         7       03C       0.04   <TS 2633   A       126     111         12     VS6       -0.9   <TS 2634   A       126     111         15     VS7       0.92   <TS 2635   A       126     111         10     04C       -0.15   <TS 2636   A       126     111         13     03C       -0.92   <TS 2637   A       126     111         10       02C       -0.88   <TS 2638   A       126     115         9       05H       0.91   <TS 2639   A       126     115         14       VS6       -0.92   <TS 2640   A       126     115         16       04C         0.9   <TS 2641   A       126     115         7       03C       0.86   <TS 2642   A       126     115         16       02C       -0.88   <TS 2643   A       126     115         13       02C       0.29   <TS 2644   A       127       52         9       03C       -0.13   <TS 2645   A       127       52         9       02C       -0.94   <TS 2646   A       127       52         9       01C       0.96   <TS 2647   A       127       56         11       DBH       1.58   <TS 2648   A       127       56         15       VS1       -0.72   <TS 2649   A       127       56         10       VS1       0.77   <TS 2650   A       127       56         11       VS4       0.9   <TS 2651   A       127       56         16       VS6       0.88   <TS 2652   A       127       72         18     VS6       -0.37   <TS 84 of 156
Percent No SG Row Column in Depth Location Elevation TS 2614 A
126 51 10 01H 0.09  
<TS 2615 A
126 51 20 03H 0.85  
<TS 2616 A
126 51 9
VS2 0.86  
<TS 2617 A
126 61 7
07H  
-0.99  
<TS 2618 A
126 63 11 07H 0.85  
<TS 2619 A
126 69 14 VS4  
-0.9  
<TS 2620 A
126 69 34 VS4 0.88  
<TS 2621 A
126 69 10 08H  
-0.88  
<TS 2622 A
126 73 12 08C  
-0.9  
<TS 2623 A
126 77 13 VS1  
-0.89  
<TS 2624 A
126 77 15 VS1 0.91  
<TS 2625 A
126 83 10 07H 0.09  
<TS 2626 A
126 85 12 06C 0.89  
<TS 2627 A
126 103 10 VS1 0.92  
<TS 2628 A
126 103 31 VS4  
-0.99  
<TS 2629 A
126 109 10 05C 0.79  
<TS 2630 A
126 109 6
05C 0.07  
<TS 2631 A
126 109 9
03C 0.9  
<TS 2632 A
126 109 7
03C 0.04  
<TS 2633 A
126 111 12 VS6  
-0.9  
<TS 2634 A
126 111 15 VS7 0.92  
<TS 2635 A
126 111 10 04C  
-0.15  
<TS 2636 A
126 111 13 03C  
-0.92  
<TS 2637 A
126 111 10 02C  
-0.88  
<TS 2638 A
126 115 9
05H 0.91  
<TS 2639 A
126 115 14 VS6  
-0.92  
<TS 2640 A
126 115 16 04C 0.9  
<TS 2641 A
126 115 7
03C 0.86  
<TS 2642 A
126 115 16 02C  
-0.88  
<TS 2643 A
126 115 13 02C 0.29  
<TS 2644 A
127 52 9
03C  
-0.13  
<TS 2645 A
127 52 9
02C  
-0.94  
<TS 2646 A
127 52 9
01C 0.96  
<TS 2647 A
127 56 11 DBH 1.58  
<TS 2648 A
127 56 15 VS1  
-0.72  
<TS 2649 A
127 56 10 VS1 0.77  
<TS 2650 A
127 56 11 VS4 0.9  
<TS 2651 A
127 56 16 VS6 0.88  
<TS 2652 A
127 72 18 VS6  
-0.37  
<TS 84 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear Percent No   SG     Row   Column     in Depth Location   Elevation TS 2653   A       127       76         13       VS1       -0.92   <TS 2654   A       127       76         9       VS4         1.05   <TS 2655   A       127       80         14       VS7         0.76   <TS 2656   A       127       80         17       06C         0.81   <TS 2657   A       127       90         11       08H       -0.88   <TS 2658   A       127       98         10       04C         -0.9   <TS 2659   A       127     106         13       VS4       -0.57   <TS 2660   A       127     108         21       05C         -0.9   <TS 2661   A       127     110         29       VS2       -0.88   <TS 2662   A       127     110         16       VS2         0.94   <TS 2663   A       127     110         14       VS4       -0.92   <TS 2664   A       127     110         15       VS4       -0.04   <TS 2665   A       127     112         25       03C         -0.9   <TS 2666   A       127     112         12       02C       -0.99   <TS 2667   A       127     114         18       VS4       -0.11   <TS 2668   A       127     114         16       05C       -0.09   <TS 2669   A       128       53         19       02H       -0.95   <TS 2670   A       128       55         7       VS1       -0.86   <TS 2671   A       128       55         11       VS7         1.19   <TS 2672   A       128       55         11       VS6         0.04   <TS 2673   A       128     69         15       08H         0.82   <TS 2674   A       128       71         18       VS1       -1.01   <TS 2675   A       128       71         31       VS1         0.92   <TS 2676   A       128       71         15       VS2         0.07   <TS 2677   A       128       77         16       07C         0.9   <TS 2678   A       128     85         14       DBH         1.84   <TS 2679   A       128     91         13       08C         0.85   <TS 2680   A       128     93         13       VS6       -0.73   <TS 2681   A       128     101         14       VS2       -0.85   <TS 2682   A       128     101         7       VS2         0.96   <TS 2683   A       128     103         13       VS2         0.85   <TS 2684   A       128     107         12       03C         0.83   <TS 2685   A       128     107         13       02C         0.86   <TS 2686   A       128     111         15       05C         0.83   <TS 2687   A       128     113         12       05C       -0.94   <TS 2688   A       129     54         25       02C       -0.92   <TS 2689   A       129     56         18       02H       0.99   <TS 2690   A       129     58         31       02H       0.84   <TS 2691   A       129     58         14       07H       -0.96   <TS 85 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear Percent No SG Row Column in Depth Location Elevation TS 2653 A
127 76 13 VS1  
-0.92  
<TS 2654 A
127 76 9
VS4 1.05  
<TS 2655 A
127 80 14 VS7 0.76  
<TS 2656 A
127 80 17 06C 0.81  
<TS 2657 A
127 90 11 08H  
-0.88  
<TS 2658 A
127 98 10 04C  
-0.9  
<TS 2659 A
127 106 13 VS4  
-0.57  
<TS 2660 A
127 108 21 05C  
-0.9  
<TS 2661 A
127 110 29 VS2  
-0.88  
<TS 2662 A
127 110 16 VS2 0.94  
<TS 2663 A
127 110 14 VS4  
-0.92  
<TS 2664 A
127 110 15 VS4  
-0.04  
<TS 2665 A
127 112 25 03C  
-0.9  
<TS 2666 A
127 112 12 02C  
-0.99  
<TS 2667 A
127 114 18 VS4  
-0.11  
<TS 2668 A
127 114 16 05C  
-0.09  
<TS 2669 A
128 53 19 02H  
-0.95  
<TS 2670 A
128 55 7
VS1  
-0.86  
<TS 2671 A
128 55 11 VS7 1.19  
<TS 2672 A
128 55 11 VS6 0.04  
<TS 2673 A
128 69 15 08H 0.82  
<TS 2674 A
128 71 18 VS1  
-1.01  
<TS 2675 A
128 71 31 VS1 0.92  
<TS 2676 A
128 71 15 VS2 0.07  
<TS 2677 A
128 77 16 07C 0.9  
<TS 2678 A
128 85 14 DBH 1.84  
<TS 2679 A
128 91 13 08C 0.85  
<TS 2680 A
128 93 13 VS6  
-0.73  
<TS 2681 A
128 101 14 VS2  
-0.85  
<TS 2682 A
128 101 7
VS2 0.96  
<TS 2683 A
128 103 13 VS2 0.85  
<TS 2684 A
128 107 12 03C 0.83  
<TS 2685 A
128 107 13 02C 0.86  
<TS 2686 A
128 111 15 05C 0.83  
<TS 2687 A
128 113 12 05C  
-0.94  
<TS 2688 A
129 54 25 02C  
-0.92  
<TS 2689 A
129 56 18 02H 0.99  
<TS 2690 A
129 58 31 02H 0.84  
<TS 2691 A
129 58 14 07H  
-0.96  
<TS 85 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2692   A       129     58         13       VS2       -0.79   <TS 2693   A       129       64       12       06C       0.88   <TS 2694   A       129       74       14       VS1       -0.92   <TS 2695   A       129       84       10       VS4       0.64   <TS 2696   A       129     86         10       DBH       1.89   <TS 2697   A       129     92         13       VS4       -0.88   <TS 2698   A       129     92         8       VS4       0.99   <TS 2699   A       129     94         12       VS4       0.59   <TS 2700   A       129     110       17       04C       0.09   <TS 2701   A       129     110       24       02C       0.86   <TS 2702   A       129     112       13       VS2       -0.83   <TS 2703   A       129     112       10       VS1       -0.9   <TS 2704   A       130       55       11       02H       0.92   <TS 2705   A       130       57       10       02H         0.9   <TS 2706   A       130       57       20       08H       0.77   <TS 2707   A       130       71       20       VS4       -0.92   <TS 2708   A       130       73       18       VS7       0.75   <TS 2709   A       130       73       11       VS6       0.95   <TS 2710   A       130       89       12       DBC       -1.99   <TS 2711   A       130       93       11       DBH       1.97   <TS 2712   A       130       95       23       VS4       -1.01   <TS 2713   A       130       99       24       03C       -0.18   <TS 2714   A       130     99         9       03C       -0.83   <TS 2715   A       130     107       13       03C       -0.29   <TS 2716   A       130     107       14       02C       0.92   <TS 2717   A       131       58       12       02H       0.86   <TS 2718   A       131       70       10       DBC       1.92   <TS 2719   A       131       76       12       06C       0.86   <TS 2720   A       131     86         12       08H       0.89   <TS 2721   A       131     94         11       08H       -1.01   <TS 2722   A       131     94         15       08H       0.97   <TS 2723   A       131     94         16       VS1         0.9   <TS 2724   A       131     96         19       06C       0.79   <TS 2725   A       131     98         12       03C       0.86   <TS 2726   A       131     106       12       03C       -0.83   <TS 2727   A       132       59       13       01C       0.81   <TS 2728   A       132     63         7       07H       -1.03   <TS 2729   A       132     63         9       VS6       0.88   <TS 2730   A       132       67       17       VS2       -0.92   <TS 86 of 156
Percent No SG Row Column in Depth Location Elevation TS 2692 A
129 58 13 VS2  
-0.79  
<TS 2693 A
129 64 12 06C 0.88  
<TS 2694 A
129 74 14 VS1  
-0.92  
<TS 2695 A
129 84 10 VS4 0.64  
<TS 2696 A
129 86 10 DBH 1.89  
<TS 2697 A
129 92 13 VS4  
-0.88  
<TS 2698 A
129 92 8
VS4 0.99  
<TS 2699 A
129 94 12 VS4 0.59  
<TS 2700 A
129 110 17 04C 0.09  
<TS 2701 A
129 110 24 02C 0.86  
<TS 2702 A
129 112 13 VS2  
-0.83  
<TS 2703 A
129 112 10 VS1  
-0.9  
<TS 2704 A
130 55 11 02H 0.92  
<TS 2705 A
130 57 10 02H 0.9  
<TS 2706 A
130 57 20 08H 0.77  
<TS 2707 A
130 71 20 VS4  
-0.92  
<TS 2708 A
130 73 18 VS7 0.75  
<TS 2709 A
130 73 11 VS6 0.95  
<TS 2710 A
130 89 12 DBC  
-1.99  
<TS 2711 A
130 93 11 DBH 1.97  
<TS 2712 A
130 95 23 VS4  
-1.01  
<TS 2713 A
130 99 24 03C  
-0.18  
<TS 2714 A
130 99 9
03C  
-0.83  
<TS 2715 A
130 107 13 03C  
-0.29  
<TS 2716 A
130 107 14 02C 0.92  
<TS 2717 A
131 58 12 02H 0.86  
<TS 2718 A
131 70 10 DBC 1.92  
<TS 2719 A
131 76 12 06C 0.86  
<TS 2720 A
131 86 12 08H 0.89  
<TS 2721 A
131 94 11 08H  
-1.01  
<TS 2722 A
131 94 15 08H 0.97  
<TS 2723 A
131 94 16 VS1 0.9  
<TS 2724 A
131 96 19 06C 0.79  
<TS 2725 A
131 98 12 03C 0.86  
<TS 2726 A
131 106 12 03C  
-0.83  
<TS 2727 A
132 59 13 01C 0.81  
<TS 2728 A
132 63 7
07H  
-1.03  
<TS 2729 A
132 63 9
VS6 0.88  
<TS 2730 A
132 67 17 VS2  
-0.92  
<TS 86 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2731   A       132       67       12       VS2       0.92   <TS 2732   A       132       81       12       DBC       1.74   <TS 2733   A       132     87         9       DBH       1.61   <TS 2734   A       132       91       19       DBC       -1.99   <TS 2735   A       132       93       30       VS2       0.73   <TS 2736   A       132       95       32       VS7       0.79   <TS 2737   A       132       97       19       VS7       -0.75   <TS 2738   A       132       97         8       08C         0   <TS 2739   A       132       99       12       06C       0.83   <TS 2740   A       132       99       14       DBC       1.88   <TS 2741   A       132     107       13       04C       0.15   <TS 2742   A       132     107       11       03C       0.81   <TS 2743   A       132     107       14       03C       -0.99   <TS 2744   A       133       60       13       02H       -0.88   <TS 2745   A       133       60       11       02H       0.94   <TS 2746   A       133       60       11       VS4       0.58   <TS 2747   A       133       60         8       VS7       -0.84   <TS 2748   A       133       60         8       VS2       -0.04   <TS 2749   A       133       64       15       05H       -0.09   <TS 2750   A       133       64       13       VS1       0.92   <TS 2751   A       133       64         8       VS6       0.81   <TS 2752   A       133       66       14       VS4       -0.88   <TS 2753   A       133       70       11       08C       0.88   <TS 2754   A       133       74       19       VS4       0.11   <TS 2755   A       133       74       22       VS4         0.7   <TS 2756   A       133       84       12       08H       -0.18   <TS 2757   A       133       86       15       DBC       -1.85   <TS 2758   A       133     88         17       DBC       1.89   <TS 2759   A       133       92       23       VS6       0.92   <TS 2760   A       133       92       16       VS7         0   <TS 2761   A       133       94       15       VS2       0.79   <TS 2762   A       133       94       14       VS4       -0.75   <TS 2763   A       133       94       22       VS6       -0.99   <TS 2764   A       133       94       13       VS6       0.99   <TS 2765   A       133       94       11       DBC       -1.98   <TS 2766   A       133       94       13       DBC         1.3   <TS 2767   A       133       96       16       VS4       -0.02   <TS 2768   A       133       98         8       DBC       1.86   <TS 2769   A       133     104       14       05C       0.81   <TS 87 of 156
Percent No SG Row Column in Depth Location Elevation TS 2731 A
132 67 12 VS2 0.92  
<TS 2732 A
132 81 12 DBC 1.74  
<TS 2733 A
132 87 9
DBH 1.61  
<TS 2734 A
132 91 19 DBC  
-1.99  
<TS 2735 A
132 93 30 VS2 0.73  
<TS 2736 A
132 95 32 VS7 0.79  
<TS 2737 A
132 97 19 VS7  
-0.75  
<TS 2738 A
132 97 8
08C 0  
<TS 2739 A
132 99 12 06C 0.83  
<TS 2740 A
132 99 14 DBC 1.88  
<TS 2741 A
132 107 13 04C 0.15  
<TS 2742 A
132 107 11 03C 0.81  
<TS 2743 A
132 107 14 03C  
-0.99  
<TS 2744 A
133 60 13 02H  
-0.88  
<TS 2745 A
133 60 11 02H 0.94  
<TS 2746 A
133 60 11 VS4 0.58  
<TS 2747 A
133 60 8
VS7  
-0.84  
<TS 2748 A
133 60 8
VS2  
-0.04  
<TS 2749 A
133 64 15 05H  
-0.09  
<TS 2750 A
133 64 13 VS1 0.92  
<TS 2751 A
133 64 8
VS6 0.81  
<TS 2752 A
133 66 14 VS4  
-0.88  
<TS 2753 A
133 70 11 08C 0.88  
<TS 2754 A
133 74 19 VS4 0.11  
<TS 2755 A
133 74 22 VS4 0.7  
<TS 2756 A
133 84 12 08H  
-0.18  
<TS 2757 A
133 86 15 DBC  
-1.85  
<TS 2758 A
133 88 17 DBC 1.89  
<TS 2759 A
133 92 23 VS6 0.92  
<TS 2760 A
133 92 16 VS7 0  
<TS 2761 A
133 94 15 VS2 0.79  
<TS 2762 A
133 94 14 VS4  
-0.75  
<TS 2763 A
133 94 22 VS6  
-0.99  
<TS 2764 A
133 94 13 VS6 0.99  
<TS 2765 A
133 94 11 DBC  
-1.98  
<TS 2766 A
133 94 13 DBC 1.3  
<TS 2767 A
133 96 16 VS4  
-0.02  
<TS 2768 A
133 98 8
DBC 1.86  
<TS 2769 A
133 104 14 05C 0.81  
<TS 87 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2770   A       133     104         11       05C       0.13   <TS 2771   A       133     104         10       06C       -0.29   <TS 2772   A       133     104         11       07C       0.79   <TS 2773   A       133     104         11       08C       0.79   <TS 2774   A       133     104         10       08C       -0.8   <TS 2775   A       134       65         9       05H       -0.09   <TS 2776   A       134       65         10       06H       0.86   <TS 2777   A       134       65         22       07H       -0.15   <TS 2778   A       134       65         13       08H         0.9   <TS 2779   A       134       65         13       DBH       -1.69   <TS 2780   A       134       65         12       VS1       0.95   <TS 2781   A       134       69         9       VS6       0.97   <TS 2782   A       134       69         18       VS7       0.22   <TS 2783   A       134       69         27       VS7       0.77   <TS 2784   A       134       71         20       VS1       0.77   <TS 2785   A       134       71         8       VS1       -0.9   <TS 2786   A       134       71         16       VS1       0.15   <TS 2787   A       134       73         17       VS6       0.94   <TS 2788   A       134       87         10       VS7       0.86   <TS 2789   A       134       89         9       DBC       -1.99   <TS 2790   A       134       91         33       DBC       1.94   <TS 2791   A       134       91         13       VS6       -0.11   <TS 2792   A       134       91         15       VS1       0.87   <TS 2793   A       134       91         20       VS6       -0.74   <TS 2794   A       134       91         14       VS6       0.89   <TS 2795   A       134       91         30       VS7       -0.87   <TS 2796   A       134       95         28       VS2         0   <TS 2797   A       134       95         29       VS4       -0.95   <TS 2798   A       134       95         13       VS4       0.95   <TS 2799   A       134       95         32       VS6       0.95   <TS 2800   A       134       95         38       VS7       0.84   <TS 2801   A       134       99         14       04C       -0.93   <TS 2802   A       134     103         13       DBC         -2   <TS 2803   A       134     103         14       02C       -0.88   <TS 2804   A       135       68         12       07H       0.86   <TS 2805   A       135       72         27       VS1       -0.95   <TS 2806   A       135       72         14       VS1       0.93   <TS 2807   A       135       72         14       VS7       0.77   <TS 2808   A       135       74         16       VS4       -0.64   <TS 88 of 156
Percent No SG Row Column in Depth Location Elevation TS 2770 A
133 104 11 05C 0.13  
<TS 2771 A
133 104 10 06C  
-0.29  
<TS 2772 A
133 104 11 07C 0.79  
<TS 2773 A
133 104 11 08C 0.79  
<TS 2774 A
133 104 10 08C  
-0.8  
<TS 2775 A
134 65 9
05H  
-0.09  
<TS 2776 A
134 65 10 06H 0.86  
<TS 2777 A
134 65 22 07H  
-0.15  
<TS 2778 A
134 65 13 08H 0.9  
<TS 2779 A
134 65 13 DBH  
-1.69  
<TS 2780 A
134 65 12 VS1 0.95  
<TS 2781 A
134 69 9
VS6 0.97  
<TS 2782 A
134 69 18 VS7 0.22  
<TS 2783 A
134 69 27 VS7 0.77  
<TS 2784 A
134 71 20 VS1 0.77  
<TS 2785 A
134 71 8
VS1  
-0.9  
<TS 2786 A
134 71 16 VS1 0.15  
<TS 2787 A
134 73 17 VS6 0.94  
<TS 2788 A
134 87 10 VS7 0.86  
<TS 2789 A
134 89 9
DBC  
-1.99  
<TS 2790 A
134 91 33 DBC 1.94  
<TS 2791 A
134 91 13 VS6  
-0.11  
<TS 2792 A
134 91 15 VS1 0.87  
<TS 2793 A
134 91 20 VS6  
-0.74  
<TS 2794 A
134 91 14 VS6 0.89  
<TS 2795 A
134 91 30 VS7  
-0.87  
<TS 2796 A
134 95 28 VS2 0  
<TS 2797 A
134 95 29 VS4  
-0.95  
<TS 2798 A
134 95 13 VS4 0.95  
<TS 2799 A
134 95 32 VS6 0.95  
<TS 2800 A
134 95 38 VS7 0.84  
<TS 2801 A
134 99 14 04C  
-0.93  
<TS 2802 A
134 103 13 DBC  
-2  
<TS 2803 A
134 103 14 02C  
-0.88  
<TS 2804 A
135 68 12 07H 0.86  
<TS 2805 A
135 72 27 VS1  
-0.95  
<TS 2806 A
135 72 14 VS1 0.93  
<TS 2807 A
135 72 14 VS7 0.77  
<TS 2808 A
135 74 16 VS4  
-0.64  
<TS 88 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2809   A       135       76         18       DBC       1.91   <TS 2810   A       135       78         15       VS1       0.96   <TS 2811   A       135       78         11       VS4       1.05   <TS 2812   A       135       78           9     VS4       0.07   <TS 2813   A       135       78         37       VS6       0.79   <TS 2814   A       135       78           9     VS7       0.76   <TS 2815   A       135       78         23       08C       -1.09   <TS 2816   A       135       78           7     08C       0.83   <TS 2817   A       135       82         15       08H       0.89   <TS 2818   A       135       82         14       VS4       -0.81   <TS 2819   A       135       82         11       08C       -1.05   <TS 2820   A       135       86         19       VS4       0.92   <TS 2821   A       135       86         16       DBC       -1.87   <TS 2822   A       135       90         22       08C       0.85   <TS 2823   A       135       94         11       VS4       0.93   <TS 2824   A       135       94         14       VS6       -0.79   <TS 2825   A       135       94         22       VS6         0.9   <TS 2826   A       135       94         25       VS7       -0.71   <TS 2827   A       135       94         26       DBC       -1.98   <TS 2828   A       135       98           9     03C       -0.95   <TS 2829   A       135     100         34       VS7       -0.73   <TS 2830   A       135     100         17     DBC         1.7   <TS 2831   A       135     100         17       04C       -0.92   <TS 2832   A       135     100         18       02C       0.86   <TS 2833   A       135     100         19       VS6       -0.84   <TS 2834   A       136       69         16       VS7       -0.86   <TS 2835   A       136       69         11     VS7       0.81   <TS 2836   A       136       69         13       DBC       -1.78   <TS 2837   A       136       69         11       DBC         1.8   <TS 2838   A       136       71         11       04H       0.87   <TS 2839   A       136       79         14     VS7       -0.7   <TS 2840   A       136       79         13     VS7       0.89   <TS 2841   A       136       79         12       08C       -1.07   <TS 2842   A       136       79         30       07C       -0.2   <TS 2843   A       136       79         12     07C       -1.02   <TS 2844   A       136       85         14       08H       -1.18   <TS 2845   A       136       85           8     07H       0.02   <TS 2846   A       136       89         10     DBC       1.57   <TS 2847   A       136       91         11     DBC       1.94   <TS 89 of 156
Percent No SG Row Column in Depth Location Elevation TS 2809 A
135 76 18 DBC 1.91  
<TS 2810 A
135 78 15 VS1 0.96  
<TS 2811 A
135 78 11 VS4 1.05  
<TS 2812 A
135 78 9
VS4 0.07  
<TS 2813 A
135 78 37 VS6 0.79  
<TS 2814 A
135 78 9
VS7 0.76  
<TS 2815 A
135 78 23 08C  
-1.09  
<TS 2816 A
135 78 7
08C 0.83  
<TS 2817 A
135 82 15 08H 0.89  
<TS 2818 A
135 82 14 VS4  
-0.81  
<TS 2819 A
135 82 11 08C  
-1.05  
<TS 2820 A
135 86 19 VS4 0.92  
<TS 2821 A
135 86 16 DBC  
-1.87  
<TS 2822 A
135 90 22 08C 0.85  
<TS 2823 A
135 94 11 VS4 0.93  
<TS 2824 A
135 94 14 VS6  
-0.79  
<TS 2825 A
135 94 22 VS6 0.9  
<TS 2826 A
135 94 25 VS7  
-0.71  
<TS 2827 A
135 94 26 DBC  
-1.98  
<TS 2828 A
135 98 9
03C  
-0.95  
<TS 2829 A
135 100 34 VS7  
-0.73  
<TS 2830 A
135 100 17 DBC 1.7  
<TS 2831 A
135 100 17 04C  
-0.92  
<TS 2832 A
135 100 18 02C 0.86  
<TS 2833 A
135 100 19 VS6  
-0.84  
<TS 2834 A
136 69 16 VS7  
-0.86  
<TS 2835 A
136 69 11 VS7 0.81  
<TS 2836 A
136 69 13 DBC  
-1.78  
<TS 2837 A
136 69 11 DBC 1.8  
<TS 2838 A
136 71 11 04H 0.87  
<TS 2839 A
136 79 14 VS7  
-0.7  
<TS 2840 A
136 79 13 VS7 0.89  
<TS 2841 A
136 79 12 08C  
-1.07  
<TS 2842 A
136 79 30 07C  
-0.2  
<TS 2843 A
136 79 12 07C  
-1.02  
<TS 2844 A
136 85 14 08H  
-1.18  
<TS 2845 A
136 85 8
07H 0.02  
<TS 2846 A
136 89 10 DBC 1.57  
<TS 2847 A
136 91 11 DBC 1.94  
<TS 89 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2848   A       136       91         9       04C       -0.9   <TS 2849   A       136       91         12       05C         -1   <TS 2850   A       136       91         12       05C       0.07   <TS 2851   A       136       91         18       07C       -0.94   <TS 2852   A       136       91         21       08C       -0.96   <TS 2853   A       136       91         28       08C       0.81   <TS 2854   A       136       91         10       VS1       0.85   <TS 2855   A       136       91         25       06C       -0.7   <TS 2856   A       136       93         14       VS6       0.66   <TS 2857   A       137       74         9       VS1       -0.71   <TS 2858   A       137       74         23       VS1       0.07   <TS 2859   A       137       74         18       VS1       0.86   <TS 2860   A       137       74         12       DBH       1.99   <TS 2861   A       137       74         10       03H       0.91   <TS 2862   A       137       76         26       VS4       -0.77   <TS 2863   A       137       76         25       VS4       -0.09   <TS 2864   A       137       76         8       VS2       -0.75   <TS 2865   A       137       76         14       VS2       -0.07   <TS 2866   A       137       76         12       VS6       -0.04   <TS 2867   A       137       78         10       08C       0.79   <TS 2868   A       137       78         19       VS4       -0.77   <TS 2869   A       137       78         21       VS4       0.99   <TS 2870   A       137       78         14       VS7       0.77   <TS 2871   A       137       80         26       VS7       0.86   <TS 2872   A       137       80         16       VS7         0.2   <TS 2873   A       137       80         18       VS6       -0.92   <TS 2874   A       137       82         10       08C       -1.05   <TS 2875   A       137       88         16       VS6       -0.11   <TS 2876   A       137       88         12       VS6       -0.73   <TS 2877   A       137       88         13       VS4       -0.68   <TS 2878   A       137       90         15       DBC       0.88   <TS 2879   A       137       90         14       05H       -0.8   <TS 2880   A       137       92         16       02C       0.83   <TS 2881   A       137       92         8       03C       0.79   <TS 2882   A       137       92         15       04C       0.79   <TS 2883   A       137       92         28       05C       0.02   <TS 2884   A       137       92         11       06C       -0.92   <TS 2885   A       137       92         17       07C       -0.94   <TS 2886   A       137       92         17       08C       -0.94   <TS 90 of 156
Percent No SG Row Column in Depth Location Elevation TS 2848 A
136 91 9
04C  
-0.9  
<TS 2849 A
136 91 12 05C  
-1  
<TS 2850 A
136 91 12 05C 0.07  
<TS 2851 A
136 91 18 07C  
-0.94  
<TS 2852 A
136 91 21 08C  
-0.96  
<TS 2853 A
136 91 28 08C 0.81  
<TS 2854 A
136 91 10 VS1 0.85  
<TS 2855 A
136 91 25 06C  
-0.7  
<TS 2856 A
136 93 14 VS6 0.66  
<TS 2857 A
137 74 9
VS1  
-0.71  
<TS 2858 A
137 74 23 VS1 0.07  
<TS 2859 A
137 74 18 VS1 0.86  
<TS 2860 A
137 74 12 DBH 1.99  
<TS 2861 A
137 74 10 03H 0.91  
<TS 2862 A
137 76 26 VS4  
-0.77  
<TS 2863 A
137 76 25 VS4  
-0.09  
<TS 2864 A
137 76 8
VS2  
-0.75  
<TS 2865 A
137 76 14 VS2  
-0.07  
<TS 2866 A
137 76 12 VS6  
-0.04  
<TS 2867 A
137 78 10 08C 0.79  
<TS 2868 A
137 78 19 VS4  
-0.77  
<TS 2869 A
137 78 21 VS4 0.99  
<TS 2870 A
137 78 14 VS7 0.77  
<TS 2871 A
137 80 26 VS7 0.86  
<TS 2872 A
137 80 16 VS7 0.2  
<TS 2873 A
137 80 18 VS6  
-0.92  
<TS 2874 A
137 82 10 08C  
-1.05  
<TS 2875 A
137 88 16 VS6  
-0.11  
<TS 2876 A
137 88 12 VS6  
-0.73  
<TS 2877 A
137 88 13 VS4  
-0.68  
<TS 2878 A
137 90 15 DBC 0.88  
<TS 2879 A
137 90 14 05H  
-0.8  
<TS 2880 A
137 92 16 02C 0.83  
<TS 2881 A
137 92 8
03C 0.79  
<TS 2882 A
137 92 15 04C 0.79  
<TS 2883 A
137 92 28 05C 0.02  
<TS 2884 A
137 92 11 06C  
-0.92  
<TS 2885 A
137 92 17 07C  
-0.94  
<TS 2886 A
137 92 17 08C  
-0.94  
<TS 90 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)
Percent No     SG     Row     Column     in Depth   Location   Elevation   TS 2887     A     137       92         27       08C         0.81     <TS 2888     A     137       92           16       VS6         0.92     <TS 2889     A     137       92         27       VS6         -0.07     <TS 2890     A     137       92         35       VS6         -0.81     <TS 2891     A     138       75         12       07H         0.88     <TS 2892     A     138       75         28       DBH         1.85     <TS 2893     A     138       75         15       08C         0.04     <TS 2894     A     138       75         10       07C         0.79     <TS 2895     A     138         75         10       08C         -1.03     <TS 2896     A     138       81           9       08H         -0.18     <TS 2897     A     138       81           14       08H         0.79     <TS 2898     A     138       81         29       DBH           2     <TS 2899     A     138       81         11       VS1         -0.99     <TS 2900     A     138       81           9       VS1         0.92     <TS 2901     A     138       81         10       VS2         -0.07     <TS 2902     A     138       81         15       VS4         -1.1     <TS 2903     A     138       81           19       VS4         0.96     <TS 2904     A     138       81         35       VS6         -0.94     <TS 2905     A     138       81         28       VS6         0.99     <TS 2906     A     138       81           17       VS7         -0.02     <TS 2907     A     138       81         16       VS7         0.96     <TS 2908     A     138       81         18       08C         -0.99     <TS 2909     A     138       83         13       08H         -1.08     <TS 2910     A     138       83           5       08H         -0.04     <TS 2911     A     138       83         11       VS1         -0.75     <TS 2912     A     138       83         23       DBH           2     <TS 2913     A     138       85         16       DBC         -1.67     <TS 2914     A     138       85         13       08C         -0.24     <TS 2915     A     138       85         26       VS7         0.81     <TS 2916     A     138       85         13       VS6         0.83     <TS 2917     A     138       85         13       08H         -1.08     <TS 2918     A     138       85           9       08C         0.86     <TS 2919     A     138       87         12       08C         0.77     <TS 2920     A     138       89         16       VS1         0.96     <TS I.             t           t           t         I*           +
Percent No SG Row Column in Depth Location Elevation TS 2887 A
I. I.       t           +           +         I.           +
137 92 27 08C 0.81  
I               +           +           +         I-           4 I               4           +           +         I.           4 91 of 156
<TS 2888 A
137 92 16 VS6 0.92  
<TS 2889 A
137 92 27 VS6  
-0.07  
<TS 2890 A
137 92 35 VS6  
-0.81  
<TS 2891 A
138 75 12 07H 0.88  
<TS 2892 A
138 75 28 DBH 1.85  
<TS 2893 A
138 75 15 08C 0.04  
<TS 2894 A
138 75 10 07C 0.79  
<TS 2895 A
138 75 10 08C  
-1.03  
<TS 2896 A
138 81 9
08H  
-0.18  
<TS 2897 A
138 81 14 08H 0.79  
<TS 2898 A
138 81 29 DBH 2  
<TS 2899 A
138 81 11 VS1  
-0.99  
<TS 2900 A
138 81 9
VS1 0.92  
<TS 2901 A
138 81 10 VS2  
-0.07  
<TS 2902 A
138 81 15 VS4  
-1.1  
<TS 2903 A
138 81 19 VS4 0.96  
<TS 2904 A
138 81 35 VS6  
-0.94  
<TS 2905 A
138 81 28 VS6 0.99  
<TS 2906 A
138 81 17 VS7  
-0.02  
<TS 2907 A
138 81 16 VS7 0.96  
<TS 2908 A
138 81 18 08C  
-0.99  
<TS 2909 A
138 83 13 08H  
-1.08  
<TS 2910 A
138 83 5
08H  
-0.04  
<TS 2911 A
138 83 11 VS1  
-0.75  
<TS 2912 A
138 83 23 DBH 2  
<TS 2913 A
138 85 16 DBC  
-1.67  
<TS 2914 A
138 85 13 08C  
-0.24  
<TS 2915 A
138 85 26 VS7 0.81  
<TS 2916 A
138 85 13 VS6 0.83  
<TS 2917 A
138 85 13 08H  
-1.08  
<TS 2918 A
138 85 9
08C 0.86  
<TS 2919 A
138 87 12 08C 0.77  
<TS 2920 A
138 89 16 VS1 0.96  
<TS I.
t t
t I*  
+
I.
I.
t  
+  
+
I.  
+
I  
+  
+  
+
I-4 I
4  
+  
+
I.
4 91 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1     B       1       10         14       03C       -0.21   <TS 2     B       1       28         18       02C       0.87   <TS 3     B       1       36         15       03C       0.86   <TS 4     B       1       124         13       02C       0.81   <TS 5     B       1       130         11       03C       0.83   <TS 6     B       1       150         23       01C       -0.7   <TS 7     B       1       158         18       02C       0.86   <TS 8     B       1       160         13       03C       -0.15   <TS 9     B       1       160         15       04H       0.86   <TS 10     B       1       160         11       04H       -0.21   <TS 11     B       1       164         18       02C       -0.87   <TS 12     B       2         11         12       02C       0.83   <TS 13     B       2       141         14       03H       -0.87   <TS 14     B       2       143         12       02C       0.84   <TS 15     B       2       163         11       02H       0.91   <TS 16     B       2       165         18       01C       0.77   <TS 17     B       3         2         11       03H       0.85   <TS 18     B       3         6         19       02C         0.8   <TS 19     B       3         6         14       02C       -0.8   <TS 20     B       3         36         17       03C       0.85   <TS 21     B       3       42         22       03C       0.83   <TS 22     B       3       162         12       02H       -0.28   <TS 23     B       4       125         12       04C       -0.87   <TS 24     B       4       133         12       04C       -0.85   <TS 25     B       4       165         16       02C       0.88   <TS 26     B       4       165         11       02C       -0.91   <TS 27     B       5       138         14       02H       -0.94   <TS 28     B       6       23         13       04C       0.89   <TS 29     B       6       137         12       04C       -0.96   <TS 30     B       6       165         21       02C       -1.12   <TS 31     B       7         2         13       05H       0.96   <TS 32     B       7       26         12       01C       -0.82   <TS 33     B       7       140         14       04C       0.93   <TS 34     B       8         3         14       03C       -0.17   <TS 35     B       8       33         11       03H       -0.91   <TS 36     B       8       129         12       04C       -0.92   <TS 37     B       8       159         11       04C         0.8   <TS 38     B       8       159         8       04C       -0.13   <TS 39     B       8       161         13       03H       0.87   <TS 92 of 156
Percent No SG Row Column in Depth Location Elevation TS 1
B 1
10 14 03C  
-0.21  
<TS 2
B 1
28 18 02C 0.87  
<TS 3
B 1
36 15 03C 0.86  
<TS 4
B 1
124 13 02C 0.81  
<TS 5
B 1
130 11 03C 0.83  
<TS 6
B 1
150 23 01C  
-0.7  
<TS 7
B 1
158 18 02C 0.86  
<TS 8
B 1
160 13 03C  
-0.15  
<TS 9
B 1
160 15 04H 0.86  
<TS 10 B
1 160 11 04H  
-0.21  
<TS 11 B
1 164 18 02C  
-0.87  
<TS 12 B
2 11 12 02C 0.83  
<TS 13 B
2 141 14 03H  
-0.87  
<TS 14 B
2 143 12 02C 0.84  
<TS 15 B
2 163 11 02H 0.91  
<TS 16 B
2 165 18 01C 0.77  
<TS 17 B
3 2
11 03H 0.85  
<TS 18 B
3 6
19 02C 0.8  
<TS 19 B
3 6
14 02C  
-0.8  
<TS 20 B
3 36 17 03C 0.85  
<TS 21 B
3 42 22 03C 0.83  
<TS 22 B
3 162 12 02H  
-0.28  
<TS 23 B
4 125 12 04C  
-0.87  
<TS 24 B
4 133 12 04C  
-0.85  
<TS 25 B
4 165 16 02C 0.88  
<TS 26 B
4 165 11 02C  
-0.91  
<TS 27 B
5 138 14 02H  
-0.94  
<TS 28 B
6 23 13 04C 0.89  
<TS 29 B
6 137 12 04C  
-0.96  
<TS 30 B
6 165 21 02C  
-1.12  
<TS 31 B
7 2
13 05H 0.96  
<TS 32 B
7 26 12 01C  
-0.82  
<TS 33 B
7 140 14 04C 0.93  
<TS 34 B
8 3
14 03C  
-0.17  
<TS 35 B
8 33 11 03H  
-0.91  
<TS 36 B
8 129 12 04C  
-0.92  
<TS 37 B
8 159 11 04C 0.8  
<TS 38 B
8 159 8
04C  
-0.13  
<TS 39 B
8 161 13 03H 0.87  
<TS 92 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 40     B       8       161         14       04H       0.88   <TS 41     B       8       165         16       02C       -1.06   <TS 42     B       9         2         10       03C       -0.13   <TS 43     B       9       46         17       DBH       0.57   <TS 44     B       9       140         14       03C       0.87   <TS 45     B       10       133         15     04C       -1.01   <TS 46     B       10       133         13     02C       0.87   <TS 47     B       10       165         16     02H       0.88   <TS 48     B       11         2         15       02H       0.88   <TS 49     B       11       32         11       04C       -0.9   <TS 50     B       11       32         11       DBH       -1.94   <TS 51     B       11       32         10     05H       0.94   <TS 52     B       11       112           9     DBC       1.61   <TS 53     B       11       136         12       02C       -0.19   <TS 54     B       11       164         25       04C       0.77   <TS 55     B       11       164         23       02C       -0.94   <TS 56     B       12         3         15       03C       -0.89   <TS 57     B       12         3         11     02C       0.83   <TS 58     B       13         2         11       04C       -0.13   <TS 59     B       13         4         16       02H       -0.84   <TS 60     B       13         6         14       03C       0.83   <TS 61     B       13         8         12       03C       -0.91   <TS 62     B       13       12         13       02C       -0.89   <TS 63     B       13       56         13       04H         0.9   <TS 64     B       13       62         16       05C       -0.96   <TS 65     B       13       140         16       02H       0.88   <TS 66     B       14       37           9     DBH       1.93   <TS 67     B       14       57         12       03H       0.89   <TS 68     B       14       57         19       DBC       -1.11   <TS 69     B       14       61         10       02H       0.87   <TS 70     B       14       121         10       05C       0.89   <TS 71     B       14       137         11       03H       0.96   <TS 72     B       14       157         14       02C       0.76   <TS 73     B       15       32         11       03H       0.12   <TS 74     B       15       130         24       05C       -0.9   <TS 75     B       15       154         19       04H       0.91   <TS 76     B       15       162           8     DBC       -1.52   <TS 77     B       15       164         16       02H       0.86   <TS 78     B       15       164         13       02C       0.84   <TS 93 of 156
Percent No SG Row Column in Depth Location Elevation TS 40 B
8 161 14 04H 0.88  
<TS 41 B
8 165 16 02C  
-1.06  
<TS 42 B
9 2
10 03C  
-0.13  
<TS 43 B
9 46 17 DBH 0.57  
<TS 44 B
9 140 14 03C 0.87  
<TS 45 B
10 133 15 04C  
-1.01  
<TS 46 B
10 133 13 02C 0.87  
<TS 47 B
10 165 16 02H 0.88  
<TS 48 B
11 2
15 02H 0.88  
<TS 49 B
11 32 11 04C  
-0.9  
<TS 50 B
11 32 11 DBH  
-1.94  
<TS 51 B
11 32 10 05H 0.94  
<TS 52 B
11 112 9
DBC 1.61  
<TS 53 B
11 136 12 02C  
-0.19  
<TS 54 B
11 164 25 04C 0.77  
<TS 55 B
11 164 23 02C  
-0.94  
<TS 56 B
12 3
15 03C  
-0.89  
<TS 57 B
12 3
11 02C 0.83  
<TS 58 B
13 2
11 04C  
-0.13  
<TS 59 B
13 4
16 02H  
-0.84  
<TS 60 B
13 6
14 03C 0.83  
<TS 61 B
13 8
12 03C  
-0.91  
<TS 62 B
13 12 13 02C  
-0.89  
<TS 63 B
13 56 13 04H 0.9  
<TS 64 B
13 62 16 05C  
-0.96  
<TS 65 B
13 140 16 02H 0.88  
<TS 66 B
14 37 9
DBH 1.93  
<TS 67 B
14 57 12 03H 0.89  
<TS 68 B
14 57 19 DBC  
-1.11  
<TS 69 B
14 61 10 02H 0.87  
<TS 70 B
14 121 10 05C 0.89  
<TS 71 B
14 137 11 03H 0.96  
<TS 72 B
14 157 14 02C 0.76  
<TS 73 B
15 32 11 03H 0.12  
<TS 74 B
15 130 24 05C  
-0.9  
<TS 75 B
15 154 19 04H 0.91  
<TS 76 B
15 162 8
DBC  
-1.52  
<TS 77 B
15 164 16 02H 0.86  
<TS 78 B
15 164 13 02C 0.84  
<TS 93 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 79     B       16         3       11       02C       0.08   <TS 80     B       16       37       11       05C       -0.22   <TS 81     B       16       55       10       DBH       -1.69   <TS 82     B       16       131       11       03C       0.87   <TS 83     B       16       145       11       04C       -0.91   <TS 84     B       17         2       12       03C       0.83   <TS 85     B       17         2         7       03C       -0.88   <TS 86     B       17       36       13       04H       -0.9   <TS 87     B       17       60         12       02C       0.89   <TS 88     B       17       62         12       01C       -0.96   <TS 89     B       17       62         8       DBH       1.34   <TS 90     B       17       144       13       03H       0.94   <TS 91     B       17       152       12       02H         0.9   <TS 92     B       18         5       11       03C       -0.13   <TS 93     B       18       137       18       VS4       0.89   <TS 94     B       18       141       13       03C       -0.96   <TS 95     B       19       60         11       03H       -0.9   <TS 96     B       19       138       15       03C       -0.9   <TS 97     B       19       156       13       04C       0.77   <TS 98     B       19       164       27       02C       0.86   <TS 99     B       20       161       17       02C       0.82   <TS 100     B       21         4       12       03C       0.85   <TS 101     B       21         8       14       03C       -0.85   <TS 102     B       21       58       16       02C       0.87   <TS 103     B       21       64         16       DBC       -1.7   <TS 104     B       21       164         8       02C       -0.17   <TS 105     B       22       11       13       02C       0.92   <TS 106     B       22       115         9       04C       -0.86   <TS 107     B       22       133       20       VS4       0.84   <TS 108     B       22       133         6       VS4       -0.78   <TS 109     B       22       163       17       02C       0.83   <TS 110     B       23       106       11       VS4       -0.9   <TS 111     B       23       160       13       03C       -0.9   <TS 112     B       23       160       12       02C       -0.18   <TS 113     B       23       160       10       02C       -0.94   <TS 114     B       24         7       15       DBH       1.66   <TS 115     B       24       53         13       02C       0.88   <TS 116     B       25         6       14       04H       0.83   <TS 117     B       25         6       12       02C       -0.81   <TS 94 of 156
Percent No SG Row Column in Depth Location Elevation TS 79 B
16 3
11 02C 0.08  
<TS 80 B
16 37 11 05C  
-0.22  
<TS 81 B
16 55 10 DBH  
-1.69  
<TS 82 B
16 131 11 03C 0.87  
<TS 83 B
16 145 11 04C  
-0.91  
<TS 84 B
17 2
12 03C 0.83  
<TS 85 B
17 2
7 03C  
-0.88  
<TS 86 B
17 36 13 04H  
-0.9  
<TS 87 B
17 60 12 02C 0.89  
<TS 88 B
17 62 12 01C  
-0.96  
<TS 89 B
17 62 8
DBH 1.34  
<TS 90 B
17 144 13 03H 0.94  
<TS 91 B
17 152 12 02H 0.9  
<TS 92 B
18 5
11 03C  
-0.13  
<TS 93 B
18 137 18 VS4 0.89  
<TS 94 B
18 141 13 03C  
-0.96  
<TS 95 B
19 60 11 03H  
-0.9  
<TS 96 B
19 138 15 03C  
-0.9  
<TS 97 B
19 156 13 04C 0.77  
<TS 98 B
19 164 27 02C 0.86  
<TS 99 B
20 161 17 02C 0.82  
<TS 100 B
21 4
12 03C 0.85  
<TS 101 B
21 8
14 03C  
-0.85  
<TS 102 B
21 58 16 02C 0.87  
<TS 103 B
21 64 16 DBC  
-1.7  
<TS 104 B
21 164 8
02C  
-0.17  
<TS 105 B
22 11 13 02C 0.92  
<TS 106 B
22 115 9
04C  
-0.86  
<TS 107 B
22 133 20 VS4 0.84  
<TS 108 B
22 133 6
VS4  
-0.78  
<TS 109 B
22 163 17 02C 0.83  
<TS 110 B
23 106 11 VS4  
-0.9  
<TS 111 B
23 160 13 03C  
-0.9  
<TS 112 B
23 160 12 02C  
-0.18  
<TS 113 B
23 160 10 02C  
-0.94  
<TS 114 B
24 7
15 DBH 1.66  
<TS 115 B
24 53 13 02C 0.88  
<TS 116 B
25 6
14 04H 0.83  
<TS 117 B
25 6
12 02C  
-0.81  
<TS 94 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 118     B       25       36         8       04H       -0.88   <TS 119     B       25       40         10       04H       -0.85   <TS 120     B       25       52         13       03H       -0.86   <TS 121     B       25       58         13       02C       -0.86   <TS 122     B       25       64         17       DBH       -1.9   <TS 123     B       25       136         13       VS4       0.83   <TS 124     B       25       148         19       02H       1.07   <TS 125     B       27       26         14       05H       0.92   <TS 126     B       27       64         17       DBH         -2   <TS 127     B       27       64         12       05H       -0.06   <TS 128     B       27       64         12       VS4       0.13   <TS 129     B       28         3         13       VS4       -0.9   <TS 130     B       28       39         21       VS4       0.97   <TS 131     B       28       63         8       VS4       0.53   <TS 132     B       29       44         7       VS4       -0.13   <TS 133     B       29       58         10       VS4       -0.11   <TS 134     B       29       120         19       03H       0.94   <TS 135     B       29       156         17       03C       -0.99   <TS 136     B       29       156         11       02H       0.94   <TS 137     B       30         5         11       02H       -0.19   <TS 138     B       30         7         12       03C       0.79   <TS 139     B       30         7         7       03C       0.06   <TS 140     B       30       9         13       02C       0.83   <TS 141     B       30       45         15       VS4       0.88   <TS 142     B       30       47         12       VS4       0.97   <TS 143     B       30       51         12       02H       0.84   <TS 144     B       30       53         14       02C       0.88   <TS 145     B       30       57         11       03C       -0.88   <TS 146     B       30       111         10       03C       -0.91   <TS 147     B       30       115         13       02H       0.84   <TS 148     B       30       127         11       05C       0.92   <TS 149     B       31       4         14       03C       -0.89   <TS 150     B       31       4         16       02C       -0.79   <TS 151     B       31       4         10       03C       0.07   <TS 152     B       31       14         13       05H       -1.06   <TS 153     B       31       46         13       03C       0.86   <TS 154     B       31       50         12       03C       0.84   <TS 155     B       31       160         12       03C       1.02   <TS 156     B       31       160         15       02C       0.88   <TS 95 of 156
Percent No SG Row Column in Depth Location Elevation TS 118 B
25 36 8
04H  
-0.88  
<TS 119 B
25 40 10 04H  
-0.85  
<TS 120 B
25 52 13 03H  
-0.86  
<TS 121 B
25 58 13 02C  
-0.86  
<TS 122 B
25 64 17 DBH  
-1.9  
<TS 123 B
25 136 13 VS4 0.83  
<TS 124 B
25 148 19 02H 1.07  
<TS 125 B
27 26 14 05H 0.92  
<TS 126 B
27 64 17 DBH  
-2  
<TS 127 B
27 64 12 05H  
-0.06  
<TS 128 B
27 64 12 VS4 0.13  
<TS 129 B
28 3
13 VS4  
-0.9  
<TS 130 B
28 39 21 VS4 0.97  
<TS 131 B
28 63 8
VS4 0.53  
<TS 132 B
29 44 7
VS4  
-0.13  
<TS 133 B
29 58 10 VS4  
-0.11  
<TS 134 B
29 120 19 03H 0.94  
<TS 135 B
29 156 17 03C  
-0.99  
<TS 136 B
29 156 11 02H 0.94  
<TS 137 B
30 5
11 02H  
-0.19  
<TS 138 B
30 7
12 03C 0.79  
<TS 139 B
30 7
7 03C 0.06  
<TS 140 B
30 9
13 02C 0.83  
<TS 141 B
30 45 15 VS4 0.88  
<TS 142 B
30 47 12 VS4 0.97  
<TS 143 B
30 51 12 02H 0.84  
<TS 144 B
30 53 14 02C 0.88  
<TS 145 B
30 57 11 03C  
-0.88  
<TS 146 B
30 111 10 03C  
-0.91  
<TS 147 B
30 115 13 02H 0.84  
<TS 148 B
30 127 11 05C 0.92  
<TS 149 B
31 4
14 03C  
-0.89  
<TS 150 B
31 4
16 02C  
-0.79  
<TS 151 B
31 4
10 03C 0.07  
<TS 152 B
31 14 13 05H  
-1.06  
<TS 153 B
31 46 13 03C 0.86  
<TS 154 B
31 50 12 03C 0.84  
<TS 155 B
31 160 12 03C 1.02  
<TS 156 B
31 160 15 02C 0.88  
<TS 95 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 157     B       32         5       13       04H       0.82   <TS 158     B       32         5       15       02C       0.77   <TS 159     B       32         7       11       02H       0.93   <TS 160     B       32       13       16       030       0.87   <TS 161     B       32       45       13       02H       0.85   <TS 162     B       32       45       13       03H       0.89   <TS 163     B       32       109       12       04C       0.85   <TS 164     B       32       151       19       VS4       0.98   <TS 165     B       32       157       17       DBH       1.41   <TS 166     B       33         4       13       010       -0.9   <TS 167     B       33       12       12       VS4       0.86   <TS 168     B       33       32       12       04H       0.96   <TS 169     B       33       52       13       03C       0.84   <TS 170     B       33       54       13       03C       -0.9   <TS 171     B       33       150       15       02H       0.72   <TS 172     B       33       158       17       020       0.81   <TS 173     B       33       160       12       02C       -0.86   <TS 174     B       33       162       16       03C       0.87   <TS 175     B       33       162       16       020       -0.92   <TS 176     B       34       11       14       DBC       -1.19   <TS 177     B       34       11       13       VS4       0.66   <TS 178     B       34       17       15       VS4       -0.4   <TS 179     B       34       31       19       VS4       0.53   <TS 180     B       34       43       11       03H       0.89   <TS 181     B       34       47       11       03H       -0.82   <TS 182     B       34       59       13       03H       -0.97   <TS 183     B       34       103       13       04H       -0.88   <TS 184     B       34       109         7       030       0.89   <TS 185     B       34       113       15       010         0.8   <TS 186     B       34       133       18       030       0.92   <TS 187     B       34       161       14       020       0.85   <TS 188     B       35       4         15       010       -0.88   <TS 189     B       35       4         11       DBC       -0.15   <TS 190     B       35       4         29       DBC         2   <TS 191     B       35       6         11       01H       -0.91   <TS 192     B       35       6         15       050       -0.44   <TS 193     B       35       6         14       030       0.85   <TS 194     B       35       36       12       03H       0.83   <TS 195     B       35       36       20       VS4         0.6   <TS 96 of 156
Percent No SG Row Column in Depth Location Elevation TS 157 B
32 5
13 04H 0.82  
<TS 158 B
32 5
15 02C 0.77  
<TS 159 B
32 7
11 02H 0.93  
<TS 160 B
32 13 16 030 0.87  
<TS 161 B
32 45 13 02H 0.85  
<TS 162 B
32 45 13 03H 0.89  
<TS 163 B
32 109 12 04C 0.85  
<TS 164 B
32 151 19 VS4 0.98  
<TS 165 B
32 157 17 DBH 1.41  
<TS 166 B
33 4
13 010  
-0.9  
<TS 167 B
33 12 12 VS4 0.86  
<TS 168 B
33 32 12 04H 0.96  
<TS 169 B
33 52 13 03C 0.84  
<TS 170 B
33 54 13 03C  
-0.9  
<TS 171 B
33 150 15 02H 0.72  
<TS 172 B
33 158 17 020 0.81  
<TS 173 B
33 160 12 02C  
-0.86  
<TS 174 B
33 162 16 03C 0.87  
<TS 175 B
33 162 16 020  
-0.92  
<TS 176 B
34 11 14 DBC  
-1.19  
<TS 177 B
34 11 13 VS4 0.66  
<TS 178 B
34 17 15 VS4  
-0.4  
<TS 179 B
34 31 19 VS4 0.53  
<TS 180 B
34 43 11 03H 0.89  
<TS 181 B
34 47 11 03H  
-0.82  
<TS 182 B
34 59 13 03H  
-0.97  
<TS 183 B
34 103 13 04H  
-0.88  
<TS 184 B
34 109 7
030 0.89  
<TS 185 B
34 113 15 010 0.8  
<TS 186 B
34 133 18 030 0.92  
<TS 187 B
34 161 14 020 0.85  
<TS 188 B
35 4
15 010  
-0.88  
<TS 189 B
35 4
11 DBC  
-0.15  
<TS 190 B
35 4
29 DBC 2  
<TS 191 B
35 6
11 01H  
-0.91  
<TS 192 B
35 6
15 050  
-0.44  
<TS 193 B
35 6
14 030 0.85  
<TS 194 B
35 36 12 03H 0.83  
<TS 195 B
35 36 20 VS4 0.6  
<TS 96 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 196     B       35       42         18       05H       0.98   <TS 197     B       35       46       12       03H       -0.8   <TS 198     B       35       46       14       03H       0.83   <TS 199     B       35       46       13       03C       0.86   <TS 200     B       35       48       10       05H       -0.85   <TS 201     B       35       52       20       DBC       1.22   <TS 202     B       35       52       19       05C       0.84   <TS 203     B       35       56       14       03H       -0.81   <TS 204     B       35       60       11       03H       -0.85   <TS 205     B       35       64       14       05H       1.01   <TS 206     B       36         5         9       03C       0.06   <TS 207     B       36         5       20       03C       0.71   <TS 208     B       36       41       14       03H       -0.85   <TS 209     B       36       45       21       VS4       -0.71   <TS 210     B       36       45       12       VS4       0.75   <TS 211     B       36       49       11       04H       0.89   <TS 212     B       36       49       16       VS4       0.22   <TS 213     B       36       51       10       VS4       -0.69   <TS 214     B       36       51       16       VS4       0.75   <TS 215     B       36       109         8       04C       0.87   <TS 216     B       36       113         9       03C       0.07   <TS 217     B       36       113       16       03C       0.83   <TS 218     B       36       119       13       03C       -0.85   <TS 219     B       36       149       20       VS4       -0.89   <TS 220     B       36       149       11       VS4       0.02   <TS 221     B       36       157       19       02C       -0.85   <TS 222     B       36       161       15       02H       0.97   <TS 223     B       36       161       13       04C       -0.15   <TS 224     B       37       6         16       01H       -0.79   <TS 225     B       37       6         17       03H       0.87   <TS 226     B       37         6       14       02C       -0.13   <TS 227     B       37       6         13       02C       -0.88   <TS 228     B       37       10         8       03C       -0.13   <TS 229     B       37       10       18       03C       -0.97   <TS 230     B       37       32       11       03H       0.94   <TS 231     B       37       36         9       03H       -0.83   <TS 232     B       37       46         10       04H       -0.87   <TS 233     B       37       48       13       02H       -0.8   <TS 234     B       37       50       13       02H       -0.89   <TS 97 of 156
Percent No SG Row Column in Depth Location Elevation TS 196 B
35 42 18 05H 0.98  
<TS 197 B
35 46 12 03H  
-0.8  
<TS 198 B
35 46 14 03H 0.83  
<TS 199 B
35 46 13 03C 0.86  
<TS 200 B
35 48 10 05H  
-0.85  
<TS 201 B
35 52 20 DBC 1.22  
<TS 202 B
35 52 19 05C 0.84  
<TS 203 B
35 56 14 03H  
-0.81  
<TS 204 B
35 60 11 03H  
-0.85  
<TS 205 B
35 64 14 05H 1.01  
<TS 206 B
36 5
9 03C 0.06  
<TS 207 B
36 5
20 03C 0.71  
<TS 208 B
36 41 14 03H  
-0.85  
<TS 209 B
36 45 21 VS4  
-0.71  
<TS 210 B
36 45 12 VS4 0.75  
<TS 211 B
36 49 11 04H 0.89  
<TS 212 B
36 49 16 VS4 0.22  
<TS 213 B
36 51 10 VS4  
-0.69  
<TS 214 B
36 51 16 VS4 0.75  
<TS 215 B
36 109 8
04C 0.87  
<TS 216 B
36 113 9
03C 0.07  
<TS 217 B
36 113 16 03C 0.83  
<TS 218 B
36 119 13 03C  
-0.85  
<TS 219 B
36 149 20 VS4  
-0.89  
<TS 220 B
36 149 11 VS4 0.02  
<TS 221 B
36 157 19 02C  
-0.85  
<TS 222 B
36 161 15 02H 0.97  
<TS 223 B
36 161 13 04C  
-0.15  
<TS 224 B
37 6
16 01H  
-0.79  
<TS 225 B
37 6
17 03H 0.87  
<TS 226 B
37 6
14 02C  
-0.13  
<TS 227 B
37 6
13 02C  
-0.88  
<TS 228 B
37 10 8
03C  
-0.13  
<TS 229 B
37 10 18 03C  
-0.97  
<TS 230 B
37 32 11 03H 0.94  
<TS 231 B
37 36 9
03H  
-0.83  
<TS 232 B
37 46 10 04H  
-0.87  
<TS 233 B
37 48 13 02H  
-0.8  
<TS 234 B
37 50 13 02H  
-0.89  
<TS 97 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 235     B       37       54         15       02H       0.86   <TS 236     B       37       54         13       04C         0.9   <TS 237     B       37       112       11       02C       -0.94   <TS 238     B       37       122       27       VS4       -0.91   <TS 239     B       37       124       22       VS4       0.76   <TS 240     B       37       124       20       VS4       -0.81   <TS 241     B       37       128       20       VS4       0.92   <TS 242     B       37       128       18       VS4       -0.84   <TS 243     B       37       148       27       VS4       -0.93   <TS 244     B       37       150       14       05H       0.92   <TS 245     B       37       156       18       VS4       0.84   <TS 246     B       37       156       16       VS4       -0.91   <TS 247     B       37       160       13       02H       0.82   <TS 248     B       37       160       23       VS4       0.86   <TS 249     B       37       160       11       VS4       -0.45   <TS 250     B       38       5         13       02C       -0.77   <TS 251     B       38       9         9       03C       -1.05   <TS 252     B       38       9         7       03C       -0.2   <TS 253     B       38       13       18       VS4       0.62   <TS 254     B       38       39         15       02H       0.94   <TS 255     B       38       45         18       02C       0.17   <TS 256     B       38       45         11       01C       0.81   <TS 257     B       38       47         11       04C       0.89   <TS 258     B       38       47         10       01C       -0.22   <TS 259     B       38       49         21       VS4       0.07   <TS 260     B       38       49         25       VS4         0.6   <TS 261     B       38       49         12       02H       -0.86   <TS 262     B       38       51         17       VS4       -0.62   <TS 263     B       38       51         11       02C       0.92   <TS 264     B       38       53         16       03H         -1   <TS 265     B       38       53         22       VS4       0.02   <TS 266     B       38       53         17       VS4       0.82   <TS 267     B       38       107       15       02C       0.82   <TS 268     B       38       109       18       VS4       -0.68   <TS 269     B       38       111         9       04C       -0.82   <TS 270     B       38       115       11       04C       0.81   <TS 271     B       38       125       34       VS4       0.92   <TS 272     B       38       125         9       VS4       0.22   <TS 273     B       38       125       12       VS4       -0.88   <TS 98 of 156
Percent No SG Row Column in Depth Location Elevation TS 235 B
37 54 15 02H 0.86  
<TS 236 B
37 54 13 04C 0.9  
<TS 237 B
37 112 11 02C  
-0.94  
<TS 238 B
37 122 27 VS4  
-0.91  
<TS 239 B
37 124 22 VS4 0.76  
<TS 240 B
37 124 20 VS4  
-0.81  
<TS 241 B
37 128 20 VS4 0.92  
<TS 242 B
37 128 18 VS4  
-0.84  
<TS 243 B
37 148 27 VS4  
-0.93  
<TS 244 B
37 150 14 05H 0.92  
<TS 245 B
37 156 18 VS4 0.84  
<TS 246 B
37 156 16 VS4  
-0.91  
<TS 247 B
37 160 13 02H 0.82  
<TS 248 B
37 160 23 VS4 0.86  
<TS 249 B
37 160 11 VS4  
-0.45  
<TS 250 B
38 5
13 02C  
-0.77  
<TS 251 B
38 9
9 03C  
-1.05  
<TS 252 B
38 9
7 03C  
-0.2  
<TS 253 B
38 13 18 VS4 0.62  
<TS 254 B
38 39 15 02H 0.94  
<TS 255 B
38 45 18 02C 0.17  
<TS 256 B
38 45 11 01C 0.81  
<TS 257 B
38 47 11 04C 0.89  
<TS 258 B
38 47 10 01C  
-0.22  
<TS 259 B
38 49 21 VS4 0.07  
<TS 260 B
38 49 25 VS4 0.6  
<TS 261 B
38 49 12 02H  
-0.86  
<TS 262 B
38 51 17 VS4  
-0.62  
<TS 263 B
38 51 11 02C 0.92  
<TS 264 B
38 53 16 03H  
-1  
<TS 265 B
38 53 22 VS4 0.02  
<TS 266 B
38 53 17 VS4 0.82  
<TS 267 B
38 107 15 02C 0.82  
<TS 268 B
38 109 18 VS4  
-0.68  
<TS 269 B
38 111 9
04C  
-0.82  
<TS 270 B
38 115 11 04C 0.81  
<TS 271 B
38 125 34 VS4 0.92  
<TS 272 B
38 125 9
VS4 0.22  
<TS 273 B
38 125 12 VS4  
-0.88  
<TS 98 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 274     B       38       127         14       02C       -0.92   <TS 275     B       38       127         7       04C       0.13   <TS 276     B       38       127         26       VS4       0.87   <TS 277     B       38       131         20       VS4       0.89   <TS 278     B       38       131         12       VS4       -0.9   <TS 279     B       38       133         14       VS4       -0.83   <TS 280     B       38       135         18       VS4       0.31   <TS 281     B       38       145         19       VS4       0.94   <TS 282     B       38       147         27       VS4       -0.84   <TS 283     B       38       147         17       VS4       0.89   <TS 284     B       38       161         22       02H       0.88   <TS 285     B       38       161         9       DBH       1.55   <TS 286     B       39       6         14       05H       0.88   <TS 287     B       39       6         15       02C       -0.57   <TS 288     B       39       6         12       02C       0.94   <TS 289     B       39       8         12       03C       0.81   <TS 290     B       39       8         15       03C       -0.99   <TS 291     B       39       10         17       03C       0.83   <TS 292     B       39       12         18       VS4       -0.57   <TS 293     B       39       22         14       DBC         1.2   <TS 294     B       39       50         11       VS4       -0.51   <TS 295     B       39       50         8       VS4       0.18   <TS 296     B       39       52         14       03H       -0.91   <TS 297     B       39       102         18       VS4       -0.68   <TS 298     B       39       108         10       DBH       -1.61   <TS 299     B       39       116         18       VS4       -0.84   <TS 300     B       39       116         33       VS4       0.83   <TS 301     B       39       120         19       VS4       0.89   <TS 302     B       39       120         10       VS4       -0.84   <TS 303     B       39       122         15       02C       -0.85   <TS 304     B       39       122         13       VS4       0.73   <TS 305     B       39       134         12       VS4       0.74   <TS 306     B       39       134         17       VS4       -0.88   <TS 307     B       39       146         12       DBC       1.79   <TS 308     B       39       150         20       VS4       0.83   <TS 309     B       39       150         17       VS4       0.07   <TS 310     B       39       160         17       02H         0.9   <TS 311     B       40       5         16       02C       -0.88   <TS 312     B       40       25           8       05H       -0.85   <TS 99 of 156
Percent No SG Row Column in Depth Location Elevation TS 274 B
38 127 14 02C  
-0.92  
<TS 275 B
38 127 7
04C 0.13  
<TS 276 B
38 127 26 VS4 0.87  
<TS 277 B
38 131 20 VS4 0.89  
<TS 278 B
38 131 12 VS4  
-0.9  
<TS 279 B
38 133 14 VS4  
-0.83  
<TS 280 B
38 135 18 VS4 0.31  
<TS 281 B
38 145 19 VS4 0.94  
<TS 282 B
38 147 27 VS4  
-0.84  
<TS 283 B
38 147 17 VS4 0.89  
<TS 284 B
38 161 22 02H 0.88  
<TS 285 B
38 161 9
DBH 1.55  
<TS 286 B
39 6
14 05H 0.88  
<TS 287 B
39 6
15 02C  
-0.57  
<TS 288 B
39 6
12 02C 0.94  
<TS 289 B
39 8
12 03C 0.81  
<TS 290 B
39 8
15 03C  
-0.99  
<TS 291 B
39 10 17 03C 0.83  
<TS 292 B
39 12 18 VS4  
-0.57  
<TS 293 B
39 22 14 DBC 1.2  
<TS 294 B
39 50 11 VS4  
-0.51  
<TS 295 B
39 50 8
VS4 0.18  
<TS 296 B
39 52 14 03H  
-0.91  
<TS 297 B
39 102 18 VS4  
-0.68  
<TS 298 B
39 108 10 DBH  
-1.61  
<TS 299 B
39 116 18 VS4  
-0.84  
<TS 300 B
39 116 33 VS4 0.83  
<TS 301 B
39 120 19 VS4 0.89  
<TS 302 B
39 120 10 VS4  
-0.84  
<TS 303 B
39 122 15 02C  
-0.85  
<TS 304 B
39 122 13 VS4 0.73  
<TS 305 B
39 134 12 VS4 0.74  
<TS 306 B
39 134 17 VS4  
-0.88  
<TS 307 B
39 146 12 DBC 1.79  
<TS 308 B
39 150 20 VS4 0.83  
<TS 309 B
39 150 17 VS4 0.07  
<TS 310 B
39 160 17 02H 0.9  
<TS 311 B
40 5
16 02C  
-0.88  
<TS 312 B
40 25 8
05H  
-0.85  
<TS 99 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 313     B       40       31       14       03H       0.85   <TS 314     B       40       31       15       VS4       0.73   <TS 315     B       40       33       12       VS4       0.24   <TS 316     B       40       35       10       04H       -0.13   <TS 317     B       40       39       14       04H       -0.94   <TS 318     B       40       41         11       04H       0.85   <TS 319     B       40       51       14       01H       0.93   <TS 320     B       40       55       10       03H       -0.85   <TS 321     B       40       115       12       03C       0.81   <TS 322     B       40       115       12       04C       0.88   <TS 323     B       40       117       19       03C       0.83   <TS 324     B       40       121       27       VS4       0.83   <TS 325     B       40       121       20       VS4       -0.74   <TS 326     B       40       123       19       VS4       0.81   <TS 327     B       40       123       12       03C       -0.9   <TS 328     B       40       125       19       02C       -0.83   <TS 329     B       40       129       14       04C       -0.91   <TS 330     B       40       143       18       05H       1.01   <TS 331     B       41       6         11       01C       0.86   <TS 332     B       41       6         9       01C       -1.08   <TS 333     B       41       8         19       04C       0.82   <TS 334     B       41       12         9       VS4       -0.87   <TS 335     B       41       12       13       VS4       -0.11   <TS 336     B       41       12       21       VS4       0.75   <TS 337     B       41       12       16       05C       0.02   <TS 338     B       41       14       21       VS4       0.26   <TS 339     B       41       14       16       VS4       0.75   <TS 340     B       41       28         13       05H       0.96   <TS 341     B       41       32         9       VS4       0.75   <TS 342     B       41       32       18       VS4       -0.07   <TS 343     B       41       34         11       04H       0.92   <TS 344     B       41       36         12       03H       -0.49   <TS 345     B       41       40         8       02C       -0.18   <TS 346     B       41       48         11       03H       0.94   <TS 347     B       41       48         12       VS4       -0.88   <TS 348     B       41       54       19       VS4       -0.77   <TS 349     B       41       54       31       VS4       0.86   <TS 350     B       41       56       14       02H       0.94   <TS 351     B       41       60         13       03H       -0.86   <TS 100 of 156
Percent No SG Row Column in Depth Location Elevation TS 313 B
40 31 14 03H 0.85  
<TS 314 B
40 31 15 VS4 0.73  
<TS 315 B
40 33 12 VS4 0.24  
<TS 316 B
40 35 10 04H  
-0.13  
<TS 317 B
40 39 14 04H  
-0.94  
<TS 318 B
40 41 11 04H 0.85  
<TS 319 B
40 51 14 01H 0.93  
<TS 320 B
40 55 10 03H  
-0.85  
<TS 321 B
40 115 12 03C 0.81  
<TS 322 B
40 115 12 04C 0.88  
<TS 323 B
40 117 19 03C 0.83  
<TS 324 B
40 121 27 VS4 0.83  
<TS 325 B
40 121 20 VS4  
-0.74  
<TS 326 B
40 123 19 VS4 0.81  
<TS 327 B
40 123 12 03C  
-0.9  
<TS 328 B
40 125 19 02C  
-0.83  
<TS 329 B
40 129 14 04C  
-0.91  
<TS 330 B
40 143 18 05H 1.01  
<TS 331 B
41 6
11 01C 0.86  
<TS 332 B
41 6
9 01C  
-1.08  
<TS 333 B
41 8
19 04C 0.82  
<TS 334 B
41 12 9
VS4  
-0.87  
<TS 335 B
41 12 13 VS4  
-0.11  
<TS 336 B
41 12 21 VS4 0.75  
<TS 337 B
41 12 16 05C 0.02  
<TS 338 B
41 14 21 VS4 0.26  
<TS 339 B
41 14 16 VS4 0.75  
<TS 340 B
41 28 13 05H 0.96  
<TS 341 B
41 32 9
VS4 0.75  
<TS 342 B
41 32 18 VS4  
-0.07  
<TS 343 B
41 34 11 04H 0.92  
<TS 344 B
41 36 12 03H  
-0.49  
<TS 345 B
41 40 8
02C  
-0.18  
<TS 346 B
41 48 11 03H 0.94  
<TS 347 B
41 48 12 VS4  
-0.88  
<TS 348 B
41 54 19 VS4  
-0.77  
<TS 349 B
41 54 31 VS4 0.86  
<TS 350 B
41 56 14 02H 0.94  
<TS 351 B
41 60 13 03H  
-0.86  
<TS 100 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 352     B       41       120         20       05C       -0.92   <TS 353     B       41       120         9       05C       0.55   <TS 354     B       41       122         15       VS4       -0.84   <TS 355     B       41       122         16       VS4       0.77   <TS 356     B       41       128         7       04C       -0.15   <TS 357     B       41       128         14       04C       -1.03   <TS 358     B       41       130         11       05C       -0.88   <TS 359     B       41       132         20       VS4       0.83   <TS 360     B       41       132         12       04C       0.15   <TS 361     B       41       132         10       03C       -0.92   <TS 362     B       41       132         10       02C       -0.15   <TS 363     B       41       134         12       03C       0.92   <TS 364     B       42       27         22       VS4       -0.82   <TS 365     B       42       37         17       VS4         0   <TS 366     B       42       39         17       VS4       0.18   <TS 367     B       42       41         9       04H       -0.86   <TS 368     B       42       41         28       VS4       0.18   <TS 369     B       42       41         36       VS4       0.77   <TS 370     B       42       45         13       VS4       0.73   <TS 371     B       42       47         13       03H       -0.82   <TS 372     B       42       51         38       VS4       -0.75   <TS 373     B       42       51         15       VS4       -0.14   <TS 374     B       42       51         20       VS4         0.8   <TS 375     B       42       57         19       VS4       0.19   <TS 376     B       42       57         36       VS4       0.74   <TS 377     B       42       123         26       VS4       0.94   <TS 378     B       42       133         11       02H       -0.84   <TS 379     B       43       6         11       05H       -0.32   <TS 380     B       43       6         26       02C       -0.15   <TS 381     B       43       6         13       02C       -1.01   <TS 382     B       43       8         13       03C         0.9   <TS 383     B       43       40         11       02C       -0.88   <TS 384     B       43       42         14       05C       0.88   <TS 385     B       43       46         17       03C       -0.86   <TS 386     B       43       48         21       05C       0.93   <TS 387     B       43       126         17       04C       -0.82   <TS 388     B       43       132         14       VS4       0.91   <TS 389     B       43       134         12       03C         -1   <TS 390     B       43       160         15       01H       -0.81   <TS 101 of 156
Percent No SG Row Column in Depth Location Elevation TS 352 B
41 120 20 05C  
-0.92  
<TS 353 B
41 120 9
05C 0.55  
<TS 354 B
41 122 15 VS4  
-0.84  
<TS 355 B
41 122 16 VS4 0.77  
<TS 356 B
41 128 7
04C  
-0.15  
<TS 357 B
41 128 14 04C  
-1.03  
<TS 358 B
41 130 11 05C  
-0.88  
<TS 359 B
41 132 20 VS4 0.83  
<TS 360 B
41 132 12 04C 0.15  
<TS 361 B
41 132 10 03C  
-0.92  
<TS 362 B
41 132 10 02C  
-0.15  
<TS 363 B
41 134 12 03C 0.92  
<TS 364 B
42 27 22 VS4  
-0.82  
<TS 365 B
42 37 17 VS4 0  
<TS 366 B
42 39 17 VS4 0.18  
<TS 367 B
42 41 9
04H  
-0.86  
<TS 368 B
42 41 28 VS4 0.18  
<TS 369 B
42 41 36 VS4 0.77  
<TS 370 B
42 45 13 VS4 0.73  
<TS 371 B
42 47 13 03H  
-0.82  
<TS 372 B
42 51 38 VS4  
-0.75  
<TS 373 B
42 51 15 VS4  
-0.14  
<TS 374 B
42 51 20 VS4 0.8  
<TS 375 B
42 57 19 VS4 0.19  
<TS 376 B
42 57 36 VS4 0.74  
<TS 377 B
42 123 26 VS4 0.94  
<TS 378 B
42 133 11 02H  
-0.84  
<TS 379 B
43 6
11 05H  
-0.32  
<TS 380 B
43 6
26 02C  
-0.15  
<TS 381 B
43 6
13 02C  
-1.01  
<TS 382 B
43 8
13 03C 0.9  
<TS 383 B
43 40 11 02C  
-0.88  
<TS 384 B
43 42 14 05C 0.88  
<TS 385 B
43 46 17 03C  
-0.86  
<TS 386 B
43 48 21 05C 0.93  
<TS 387 B
43 126 17 04C  
-0.82  
<TS 388 B
43 132 14 VS4 0.91  
<TS 389 B
43 134 12 03C  
-1  
<TS 390 B
43 160 15 01H  
-0.81  
<TS 101 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 391     B       44       19       12       VS4       0.18   <TS 392     B       44       21       24       VS4       -0.89   <TS 393     B       44       21       30       VS4       0.77   <TS 394     B       44       23       15       VS4       0.82   <TS 395     B       44       23       27       DBH       -1.61   <TS 396     B       44       27       25       VS4       -0.8   <TS 397     B       44       27       25       VS4       0.95   <TS 398     B       44       27       12       DBC       -1.32   <TS 399     B       44       29       14       VS4       -0.83   <TS 400     B       44       29       31       VS4       -0.02   <TS 401     B       44       29       12       VS4       0.79   <TS 402     B       44       31       37       VS4       -0.79   <TS 403     B       44       31       21       VS4       0.02   <TS 404     B       44       31       20       DBC       1.19   <TS 405     B       44       31         17       02C       0.86   <TS 406     B       44       33       11       VS4       0.22   <TS 407     B       44       33         11       VS4       0.93   <TS 408     B       44       37         19       VS4       0.77   <TS 409     B       44       37         25       VS4       0.22   <TS 410     B       44       41         16       02C       -0.15   <TS 411     B       44       45         24       VS4       0.79   <TS 412     B       44       45         21       04C       0.44   <TS 413     B       44       45         16       03C       0.88   <TS 414     B       44       47         23       VS4       -0.68   <TS 415     B       44       47         21       VS4       0.02   <TS 416     B       44       53         11       VS4       -0.68   <TS 417     B       44       57         21       VS4       -0.78   <TS 418     B       44       57         15       VS4       0.11   <TS 419     B       44       57         9       VS4       0.82   <TS 420     B       44       59         15       VS4       0.81   <TS 421     B       44       59         25       VS4         0   <TS 422     B       44       61         10       02H       -0.11   <TS 423     B       44       63         12       VS4       -0.93   <TS 424     B       44       63         24       VS4       0.83   <TS 425     B       44       65         23       VS4         0     <TS 426     B       44       65         21       VS4       0.82   <TS 427     B       44       99         14       DBH       1.85   <TS 428     B       44       101       12       04C       0.8   <TS 429     B       44       103       34       VS4       0.89   <TS 102 of 156
Percent No SG Row Column in Depth Location Elevation TS 391 B
44 19 12 VS4 0.18  
<TS 392 B
44 21 24 VS4  
-0.89  
<TS 393 B
44 21 30 VS4 0.77  
<TS 394 B
44 23 15 VS4 0.82  
<TS 395 B
44 23 27 DBH  
-1.61  
<TS 396 B
44 27 25 VS4  
-0.8  
<TS 397 B
44 27 25 VS4 0.95  
<TS 398 B
44 27 12 DBC  
-1.32  
<TS 399 B
44 29 14 VS4  
-0.83  
<TS 400 B
44 29 31 VS4  
-0.02  
<TS 401 B
44 29 12 VS4 0.79  
<TS 402 B
44 31 37 VS4  
-0.79  
<TS 403 B
44 31 21 VS4 0.02  
<TS 404 B
44 31 20 DBC 1.19  
<TS 405 B
44 31 17 02C 0.86  
<TS 406 B
44 33 11 VS4 0.22  
<TS 407 B
44 33 11 VS4 0.93  
<TS 408 B
44 37 19 VS4 0.77  
<TS 409 B
44 37 25 VS4 0.22  
<TS 410 B
44 41 16 02C  
-0.15  
<TS 411 B
44 45 24 VS4 0.79  
<TS 412 B
44 45 21 04C 0.44  
<TS 413 B
44 45 16 03C 0.88  
<TS 414 B
44 47 23 VS4  
-0.68  
<TS 415 B
44 47 21 VS4 0.02  
<TS 416 B
44 53 11 VS4  
-0.68  
<TS 417 B
44 57 21 VS4  
-0.78  
<TS 418 B
44 57 15 VS4 0.11  
<TS 419 B
44 57 9
VS4 0.82  
<TS 420 B
44 59 15 VS4 0.81  
<TS 421 B
44 59 25 VS4 0  
<TS 422 B
44 61 10 02H  
-0.11  
<TS 423 B
44 63 12 VS4  
-0.93  
<TS 424 B
44 63 24 VS4 0.83  
<TS 425 B
44 65 23 VS4 0  
<TS 426 B
44 65 21 VS4 0.82  
<TS 427 B
44 99 14 DBH 1.85  
<TS 428 B
44 101 12 04C 0.8  
<TS 429 B
44 103 34 VS4 0.89  
<TS 102 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 430     B       44       107       16       VS4       -0.91   <TS 431     B       44       107       28       VS4       0.89   <TS 432     B       44       107         8       06C       0.11   <TS 433     B       44       113       11       DBH       1.56   <TS 434     B       44       121       10       03C       0.81   <TS 435     B       44       127       20       02C       0.88   <TS 436     B       44       131       12       VS4       0.84   <TS 437     B       44       131       16       03C         0.9   <TS 438     B       44       137       17       04C       -0.78   <TS 439     B       44       159       15       01H       -0.95   <TS 440     B       45         6         20       02C       -0.15   <TS 441     B       45         6         25       02C       -0.94   <TS 442     B       45         8         10       01C       -0.11   <TS 443     B       45         16         6       DBH       -1.59   <TS 444     B       45       32         23       VS4       -0.84   <TS 445     B       45       32         20       VS4       0.24   <TS 446     B       45       32         15       VS4       1.01   <TS 447     B       45       34         32       VS4       0.07   <TS 448     B       45       34         18       VS4       -0.77   <TS 449     B       45       34         11       VS4         0.8   <TS 450     B       45       34         14       06H       1.19   <TS 451     B       45       36         13       04H       -0.81   <TS 452     B       45       36         27       VS4         0   <TS 453     B       45       36         18       VS4       0.82   <TS 454     B       45       38         10       VS4       -0.71   <TS 455     B       45       38         12       VS4       0.22   <TS 456     B       45       42         24       VS4       -0.84   <TS 457     B       45       42         17       VS4       0.9   <TS 458     B       45       48         13       VS4       -0.81   <TS 459     B       45       48         19       VS4       0.15   <TS 460     B       45       48         19       VS4       0.66   <TS 461     B       45       56         16       03H       0.85   <TS 462     B       45       64         16       DBC       -1.85   <TS 463     B       45       66         15       VS4       0.81   <TS 464     B       45       66         16       VS4         0   <TS 465     B       45       108         7       03H       0.11   <TS 466     B       45       108       12       04C         0   <TS 467     B       45       110       13       02C       0.87   <TS 468     B       45       114       11       03C       0.83   <TS 103 of 156
Percent No SG Row Column in Depth Location Elevation TS 430 B
44 107 16 VS4  
-0.91  
<TS 431 B
44 107 28 VS4 0.89  
<TS 432 B
44 107 8
06C 0.11  
<TS 433 B
44 113 11 DBH 1.56  
<TS 434 B
44 121 10 03C 0.81  
<TS 435 B
44 127 20 02C 0.88  
<TS 436 B
44 131 12 VS4 0.84  
<TS 437 B
44 131 16 03C 0.9  
<TS 438 B
44 137 17 04C  
-0.78  
<TS 439 B
44 159 15 01H  
-0.95  
<TS 440 B
45 6
20 02C  
-0.15  
<TS 441 B
45 6
25 02C  
-0.94  
<TS 442 B
45 8
10 01C  
-0.11  
<TS 443 B
45 16 6
DBH  
-1.59  
<TS 444 B
45 32 23 VS4  
-0.84  
<TS 445 B
45 32 20 VS4 0.24  
<TS 446 B
45 32 15 VS4 1.01  
<TS 447 B
45 34 32 VS4 0.07  
<TS 448 B
45 34 18 VS4  
-0.77  
<TS 449 B
45 34 11 VS4 0.8  
<TS 450 B
45 34 14 06H 1.19  
<TS 451 B
45 36 13 04H  
-0.81  
<TS 452 B
45 36 27 VS4 0  
<TS 453 B
45 36 18 VS4 0.82  
<TS 454 B
45 38 10 VS4  
-0.71  
<TS 455 B
45 38 12 VS4 0.22  
<TS 456 B
45 42 24 VS4  
-0.84  
<TS 457 B
45 42 17 VS4 0.9  
<TS 458 B
45 48 13 VS4  
-0.81  
<TS 459 B
45 48 19 VS4 0.15  
<TS 460 B
45 48 19 VS4 0.66  
<TS 461 B
45 56 16 03H 0.85  
<TS 462 B
45 64 16 DBC  
-1.85  
<TS 463 B
45 66 15 VS4 0.81  
<TS 464 B
45 66 16 VS4 0  
<TS 465 B
45 108 7
03H 0.11  
<TS 466 B
45 108 12 04C 0  
<TS 467 B
45 110 13 02C 0.87  
<TS 468 B
45 114 11 03C 0.83  
<TS 103 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 469     B       45       118       24       06H       -0.2   <TS 470     B       45       120       18       VS4       -0.83   <TS 471     B       45       120       15       VS4         0.9   <TS 472     B       45       120       12       02C       -0.76   <TS 473     B       45       122       23       VS4       -0.96   <TS 474     B       45       122       29       VS4       0.88   <TS 475     B       45       122       15       06C       -0.66   <TS 476     B       45       126       17       020       0.86   <TS 477     B       45       128       12       03H       -0.98   <TS 478     B       45       130       12       VS4       0.81   <TS 479     B       45       132       17       VS4         0.9   <TS 480     B       45       140       12       VS4       -0.85   <TS 481     B       45       140       26       VS4       0.87   <TS 482     B       45       140       17       DBH       -1.69   <TS 483     B       45       140       13       06C       -0.57   <TS 484     B       45       148       17       VS4       0.75   <TS 485     B       45       148       19       06C       -0.88   <TS 486     B       45       160         9       01H       -0.9   <TS 487     B       45       160       11       01H       0.85   <TS 488     B       46         7         7       010       0.85   <TS 489     B       46         7         21       010       -0.15   <TS 490     B       46       21         11       VS4       0.79   <TS 491     B       46       23         19       VS4       -0.95   <TS 492     B       46       23         23       VS4       0.93   <TS 493     B       46       25         16       VS4       -0.66   <TS 494     B       46       33         27       VS4       -0.81   <TS 495     B       46       33         13       VS4       0.02   <TS 496     B       46       33         12       DBC       -1.63   <TS 497     B       46       35         23       VS4       -0.8   <TS 498     B       46       37         13       02H       0.92   <TS 499     B       46       37         14       VS4       -0.95   <TS 500     B       46       37         20       VS4       0.86   <TS 501     B       46       37         12       DBC       -1.37   <TS 502     B       46       39         25       VS4       0.73   <TS 503     B       46       39         14       VS4       0.11   <TS 504     B       46       41         14       04H       0.91   <TS 505     B       46       47         12       02H       -0.19   <TS 506     B       46       59         13       02H       1.07   <TS 507     B       46       59         13       030       0.89   <TS 104 of 156
Percent No SG Row Column in Depth Location Elevation TS 469 B
45 118 24 06H  
-0.2  
<TS 470 B
45 120 18 VS4  
-0.83  
<TS 471 B
45 120 15 VS4 0.9  
<TS 472 B
45 120 12 02C  
-0.76  
<TS 473 B
45 122 23 VS4  
-0.96  
<TS 474 B
45 122 29 VS4 0.88  
<TS 475 B
45 122 15 06C  
-0.66  
<TS 476 B
45 126 17 020 0.86  
<TS 477 B
45 128 12 03H  
-0.98  
<TS 478 B
45 130 12 VS4 0.81  
<TS 479 B
45 132 17 VS4 0.9  
<TS 480 B
45 140 12 VS4  
-0.85  
<TS 481 B
45 140 26 VS4 0.87  
<TS 482 B
45 140 17 DBH  
-1.69  
<TS 483 B
45 140 13 06C  
-0.57  
<TS 484 B
45 148 17 VS4 0.75  
<TS 485 B
45 148 19 06C  
-0.88  
<TS 486 B
45 160 9
01H  
-0.9  
<TS 487 B
45 160 11 01H 0.85  
<TS 488 B
46 7
7 010 0.85  
<TS 489 B
46 7
21 010  
-0.15  
<TS 490 B
46 21 11 VS4 0.79  
<TS 491 B
46 23 19 VS4  
-0.95  
<TS 492 B
46 23 23 VS4 0.93  
<TS 493 B
46 25 16 VS4  
-0.66  
<TS 494 B
46 33 27 VS4  
-0.81  
<TS 495 B
46 33 13 VS4 0.02  
<TS 496 B
46 33 12 DBC  
-1.63  
<TS 497 B
46 35 23 VS4  
-0.8  
<TS 498 B
46 37 13 02H 0.92  
<TS 499 B
46 37 14 VS4  
-0.95  
<TS 500 B
46 37 20 VS4 0.86  
<TS 501 B
46 37 12 DBC  
-1.37  
<TS 502 B
46 39 25 VS4 0.73  
<TS 503 B
46 39 14 VS4 0.11  
<TS 504 B
46 41 14 04H 0.91  
<TS 505 B
46 47 12 02H  
-0.19  
<TS 506 B
46 59 13 02H 1.07  
<TS 507 B
46 59 13 030 0.89  
<TS 104 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear'*
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear'*
Percent No   SG     Row   Column     in Depth Location Elevation TS 508     B       46       69         17       DBH       -1.76 <TS 509     B       46       103         14       04C         0.83 <TS 510     B       46       115         11       02C         0.87 <TS 511     B       46       125         8       02C       -0.94 <TS 512     B       46       129         16       VS4         0.92 <TS 513     B       46       129         12       03C         0.85 <TS 514     B       46       131         14       VS4         0.02 <TS 515     B       46       131         11       VS4       -0.88 <TS 516     B       46       135         12       03H       -0.87 <TS 517     B       46       135         13       VS4       -0.84 <TS 518     B       46       143         15       DBC         1.39 <TS 519     B       46       151         32       VS4         0.87 <TS 520     B       46       159         15       01C         0.13 <TS 521     B       47         8         10       01H         0.9 <TS 522     B       47       12         19       VS4       -0.81 <TS 523     B       47       12         24       VS4         0.9 <TS 524     B       47       14         23       VS4         0.09 <TS 525     B       47       14         26       VS4         0.79 <TS 526     B       47       20         26       VS4       -0.88 <TS 527     B       47       20         28       VS4         0.82 <TS 528     B       47       22         19       VS4       -0.82 <TS 529     B       47       22         18       VS4         1.04 <TS 530     B       47       34         13       VS4         0.96 <TS 531     B       47       40         12       06C       -0.75 <TS 532     B       47       42         14       DBC         1.53 <TS 533     B       47       46         23       VS4       -0.77 <TS 534     B       47       46         20       VS4       -0.02 <TS 535     B       47       46         12       VS4         0.95 <TS 536     B       47       48         14       06C         0.75 <TS 537     B       47       56         17       VS4       -0.77 <TS 538     B       47       56         29       VS4         0.83 <TS 539     B       47       58         17       VS4         0.91 <TS 540     B       47       70         17       VS4       -0.66 <TS 541     B       47       96         23       VS4         0.77 <TS 542     B       47       96         16       VS4       -0.88 <TS 543     B       47       96         11       06C       -0.07 <TS 544     B       47       96         7       DBH         1.79 <TS 545     B       47       98         23       VS4         0.87 <TS 546     B       47       102         12       VS4       -0.89 <TS 105 of 156
Percent No SG Row Column in Depth Location Elevation TS 508 B
46 69 17 DBH  
-1.76  
<TS 509 B
46 103 14 04C 0.83  
<TS 510 B
46 115 11 02C 0.87  
<TS 511 B
46 125 8
02C  
-0.94  
<TS 512 B
46 129 16 VS4 0.92  
<TS 513 B
46 129 12 03C 0.85  
<TS 514 B
46 131 14 VS4 0.02  
<TS 515 B
46 131 11 VS4  
-0.88  
<TS 516 B
46 135 12 03H  
-0.87  
<TS 517 B
46 135 13 VS4  
-0.84  
<TS 518 B
46 143 15 DBC 1.39  
<TS 519 B
46 151 32 VS4 0.87  
<TS 520 B
46 159 15 01C 0.13  
<TS 521 B
47 8
10 01H 0.9  
<TS 522 B
47 12 19 VS4  
-0.81  
<TS 523 B
47 12 24 VS4 0.9  
<TS 524 B
47 14 23 VS4 0.09  
<TS 525 B
47 14 26 VS4 0.79  
<TS 526 B
47 20 26 VS4  
-0.88  
<TS 527 B
47 20 28 VS4 0.82  
<TS 528 B
47 22 19 VS4  
-0.82  
<TS 529 B
47 22 18 VS4 1.04  
<TS 530 B
47 34 13 VS4 0.96  
<TS 531 B
47 40 12 06C  
-0.75  
<TS 532 B
47 42 14 DBC 1.53  
<TS 533 B
47 46 23 VS4  
-0.77  
<TS 534 B
47 46 20 VS4  
-0.02  
<TS 535 B
47 46 12 VS4 0.95  
<TS 536 B
47 48 14 06C 0.75  
<TS 537 B
47 56 17 VS4  
-0.77  
<TS 538 B
47 56 29 VS4 0.83  
<TS 539 B
47 58 17 VS4 0.91  
<TS 540 B
47 70 17 VS4  
-0.66  
<TS 541 B
47 96 23 VS4 0.77  
<TS 542 B
47 96 16 VS4  
-0.88  
<TS 543 B
47 96 11 06C  
-0.07  
<TS 544 B
47 96 7
DBH 1.79  
<TS 545 B
47 98 23 VS4 0.87  
<TS 546 B
47 102 12 VS4  
-0.89  
<TS 105 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 547     B       47       108         27       06H       1.03   <TS 548     B       47       108         16       VS4       -0.38   <TS 549     B       47       108         19       VS4       -0.85   <TS 550     B       47       108         23       VS4       0.76   <TS 551     B       47       114         14       06C       1.03   <TS 552     B       47       116         16       04C       -0.91   <TS 553     B       47       126         28       VS4       0.88   <TS 554     B       47       126         27       VS4       -0.77   <TS 555     B       47       128         24       VS4       -0.78   <TS 556     B       47       132         13       VS4       0.83   <TS 557     B       47       132         10       VS4       -0.78   <TS 558     B       47       132         11       03C       -0.89   <TS 559     B       47       134         9       02C       -0.16   <TS 560     B       47       138         12       DBH       -1.58   <TS 561     B       47       140         16       VS4       0.81   <TS 562     B       47       148         16       04C       0.87   <TS 563     B       47       156         7       01C       0.07   <TS 564     B       48       7         13       01H         0.9   <TS 565     B       48       9         34       VS4       -0.73   <TS 566     B       48       9         34       VS4       -0.04   <TS 567     B       48       9         21       VS4       0.77   <TS 568     B       48       13         22       VS4       -0.77   <TS 569     B       48       13         29       VS4         0.2   <TS 570     B       48       13         21       VS4       0.77   <TS 571     B       48       13         17       VS4       -0.18   <TS 572     B       48       39         13       04H       0.91   <TS 573     B       48       61         13       04H       0.91   <TS 574     B       48       65         26       VS4       -0.82   <TS 575     B       48       67         15       VS4       0.25   <TS 576     B       48       67         14       VS4       0.83   <TS 577     B       48       99         16       03C       0.92   <TS 578     B       48       107         16       04C       0.92   <TS 579     B       48       107         10       02C       0.86   <TS 580     B       48       111         14       04C         0.8   <TS 581     B       48       119         21       04C       -0.87   <TS 582     B       48       123         14       VS4       0.88   <TS 583     B       48       125         15       03C       0.87   <TS 584     B       48       129         13       03C       -0.13   <TS 585     B       48       133         6       04C       0.13   <TS 106 of 156
Percent No SG Row Column in Depth Location Elevation TS 547 B
47 108 27 06H 1.03  
<TS 548 B
47 108 16 VS4  
-0.38  
<TS 549 B
47 108 19 VS4  
-0.85  
<TS 550 B
47 108 23 VS4 0.76  
<TS 551 B
47 114 14 06C 1.03  
<TS 552 B
47 116 16 04C  
-0.91  
<TS 553 B
47 126 28 VS4 0.88  
<TS 554 B
47 126 27 VS4  
-0.77  
<TS 555 B
47 128 24 VS4  
-0.78  
<TS 556 B
47 132 13 VS4 0.83  
<TS 557 B
47 132 10 VS4  
-0.78  
<TS 558 B
47 132 11 03C  
-0.89  
<TS 559 B
47 134 9
02C  
-0.16  
<TS 560 B
47 138 12 DBH  
-1.58  
<TS 561 B
47 140 16 VS4 0.81  
<TS 562 B
47 148 16 04C 0.87  
<TS 563 B
47 156 7
01C 0.07  
<TS 564 B
48 7
13 01H 0.9  
<TS 565 B
48 9
34 VS4  
-0.73  
<TS 566 B
48 9
34 VS4  
-0.04  
<TS 567 B
48 9
21 VS4 0.77  
<TS 568 B
48 13 22 VS4  
-0.77  
<TS 569 B
48 13 29 VS4 0.2  
<TS 570 B
48 13 21 VS4 0.77  
<TS 571 B
48 13 17 VS4  
-0.18  
<TS 572 B
48 39 13 04H 0.91  
<TS 573 B
48 61 13 04H 0.91  
<TS 574 B
48 65 26 VS4  
-0.82  
<TS 575 B
48 67 15 VS4 0.25  
<TS 576 B
48 67 14 VS4 0.83  
<TS 577 B
48 99 16 03C 0.92  
<TS 578 B
48 107 16 04C 0.92  
<TS 579 B
48 107 10 02C 0.86  
<TS 580 B
48 111 14 04C 0.8  
<TS 581 B
48 119 21 04C  
-0.87  
<TS 582 B
48 123 14 VS4 0.88  
<TS 583 B
48 125 15 03C 0.87  
<TS 584 B
48 129 13 03C  
-0.13  
<TS 585 B
48 133 6
04C 0.13  
<TS 106 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 586     B       48       139       16       03H       0.96   <TS 587     B       48       141       14       03H       -0.92   <TS 588     B       48       159       11       01H       -0.93   <TS 589     B       48       159       12       01C       -1.01   <TS 590     B       49       8         24       VS4       0.88   <TS 591     B       49       8         5       DBC       -1.67   <TS 592     B       49       10       24       01C       0.93   <TS 593     B       49       12         8       DBC       1.76   <TS 594     B       49       26       16       03H       0.92   <TS 595     B       49       34       12       VS4       -0.81   <TS 596     B       49       34       39       VS4       0.84   <TS 597     B       49       46         21       VS4       -0.82   <TS 598     B       49       56         9       03H       -0.91   <TS 599     B       49       74       27       DBH         -2   <TS 600     B       49       106       14       VS4       0.31   <TS 601     B       49       122       12       04C       0.89   <TS 602     B       49       124       21       VS4       -0.76   <TS 603     B       49       126       12       02C       -0.87   <TS 604     B       49       132       16       03C       -0.86   <TS 605     B       49       144       16       02H       0.93   <TS 606     B       49       158       16       01C       0.09   <TS 607     B       50       7         12       DBH       1.79   <TS 608     B       50       9         12       01C       -0.89   <TS 609     B       50       63         15       DBH       -1.32   <TS 610     B       50       109         9       03C       0.93   <TS 611     B       50       127       13       03C       -0.87   <TS 612     B       50       157       20       01H       -0.9   <TS 613     B       50       159       13       01C       0.88   <TS 614     B       51       36         11       03C       0.86   <TS 615     B       51       36         15       03C       -0.9   <TS 616     B       51       58         12       01H         0.9   <TS 617     B       51       58         14       03H       0.87   <TS 618     B       51       64         17       02C       0.91   <TS 619     B       51       72         13       VS3       -0.7   <TS 620     B       51       116       15       VS3       -0.85   <TS 621     B       51       116       13       02C       -0.89   <TS 622     B       51       134       12       03C       -0.89   <TS 623     B       51       136       13       03C       -0.92   <TS 624     B       51       138         9       02C       -0.13   <TS 107 of 156
Percent No SG Row Column in Depth Location Elevation TS 586 B
48 139 16 03H 0.96  
<TS 587 B
48 141 14 03H  
-0.92  
<TS 588 B
48 159 11 01H  
-0.93  
<TS 589 B
48 159 12 01C  
-1.01  
<TS 590 B
49 8
24 VS4 0.88  
<TS 591 B
49 8
5 DBC  
-1.67  
<TS 592 B
49 10 24 01C 0.93  
<TS 593 B
49 12 8
DBC 1.76  
<TS 594 B
49 26 16 03H 0.92  
<TS 595 B
49 34 12 VS4  
-0.81  
<TS 596 B
49 34 39 VS4 0.84  
<TS 597 B
49 46 21 VS4  
-0.82  
<TS 598 B
49 56 9
03H  
-0.91  
<TS 599 B
49 74 27 DBH  
-2  
<TS 600 B
49 106 14 VS4 0.31  
<TS 601 B
49 122 12 04C 0.89  
<TS 602 B
49 124 21 VS4  
-0.76  
<TS 603 B
49 126 12 02C  
-0.87  
<TS 604 B
49 132 16 03C  
-0.86  
<TS 605 B
49 144 16 02H 0.93  
<TS 606 B
49 158 16 01C 0.09  
<TS 607 B
50 7
12 DBH 1.79  
<TS 608 B
50 9
12 01C  
-0.89  
<TS 609 B
50 63 15 DBH  
-1.32  
<TS 610 B
50 109 9
03C 0.93  
<TS 611 B
50 127 13 03C  
-0.87  
<TS 612 B
50 157 20 01H  
-0.9  
<TS 613 B
50 159 13 01C 0.88  
<TS 614 B
51 36 11 03C 0.86  
<TS 615 B
51 36 15 03C  
-0.9  
<TS 616 B
51 58 12 01H 0.9  
<TS 617 B
51 58 14 03H 0.87  
<TS 618 B
51 64 17 02C 0.91  
<TS 619 B
51 72 13 VS3  
-0.7  
<TS 620 B
51 116 15 VS3  
-0.85  
<TS 621 B
51 116 13 02C  
-0.89  
<TS 622 B
51 134 12 03C  
-0.89  
<TS 623 B
51 136 13 03C  
-0.92  
<TS 624 B
51 138 9
02C  
-0.13  
<TS 107 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 625     B       51       138         8       02C       -0.94   <TS 626     B       51       156       22       VS5       -0.84   <TS 627     B       52       11       10       01C       -0.15   <TS 628     B       52       11         8       01C       -0.95   <TS 629     B       52       25         13       02H       0.82   <TS 630     B       52       65         12       03C       0.87   <TS 631     B       52       107       14       02C       0.87   <TS 632     B       52       123       10       03C       -0.08   <TS 633     B       52       125       10       03C       0.87   <TS 634     B       52       131       27       VS5       -0.55   <TS 635     B       53       8         14       01C       0.79   <TS 636     B       53       32         17       05C       0.68   <TS 637     B       53       50         11       04H       0.91   <TS 638     B       53       56         15       03H       0.87   <TS 639     B       53       60         13       04H       0.99   <TS 640     B       53       80         22       03C       0.77   <TS 641     B       53       106       12       04C       0.83   <TS 642     B       53       108       10       03C       0.86   <TS 643     B       53       118       14       02C       -0.13   <TS 644     B       53       120       11       04C       0.9   <TS 645     B       53       128       17       03C       0.94   <TS 646     B       53       132       14       02C       0.92   <TS 647     B       53       134       12       03C       0.87   <TS 648     B       53       138       12       VS3       -0.93   <TS 649     B       54       17         12       VS3       -0.88   <TS 650     B       54       17         12       VS3       0.9   <TS 651     B       54       61         11       05H       0.96   <TS 652     B       54       69         11       03H         1   <TS 653     B       54       71         13       02H       0.94   <TS 654     B       54       103       11       04C       0.81   <TS 655     B       54       103       12       VS3       -0.85   <TS 656     B       54       117       14       02C       0.89   <TS 657     B       54       121       15       04C       -0.96   <TS 658     B       54       143       13       VS3       -0.87   <TS 659     B       55       14         12       VS5       -0.86   <TS 660     B       55       32         14       VS3       -0.59   <TS 661     B       55       54         14       VS3       -0.75   <TS 662     B       55       56         11       03H       0.91   <TS 663     B       55       60         14       04H       0.91   <TS 108 of 156
Percent No SG Row Column in Depth Location Elevation TS 625 B
51 138 8
02C  
-0.94  
<TS 626 B
51 156 22 VS5  
-0.84  
<TS 627 B
52 11 10 01C  
-0.15  
<TS 628 B
52 11 8
01C  
-0.95  
<TS 629 B
52 25 13 02H 0.82  
<TS 630 B
52 65 12 03C 0.87  
<TS 631 B
52 107 14 02C 0.87  
<TS 632 B
52 123 10 03C  
-0.08  
<TS 633 B
52 125 10 03C 0.87  
<TS 634 B
52 131 27 VS5  
-0.55  
<TS 635 B
53 8
14 01C 0.79  
<TS 636 B
53 32 17 05C 0.68  
<TS 637 B
53 50 11 04H 0.91  
<TS 638 B
53 56 15 03H 0.87  
<TS 639 B
53 60 13 04H 0.99  
<TS 640 B
53 80 22 03C 0.77  
<TS 641 B
53 106 12 04C 0.83  
<TS 642 B
53 108 10 03C 0.86  
<TS 643 B
53 118 14 02C  
-0.13  
<TS 644 B
53 120 11 04C 0.9  
<TS 645 B
53 128 17 03C 0.94  
<TS 646 B
53 132 14 02C 0.92  
<TS 647 B
53 134 12 03C 0.87  
<TS 648 B
53 138 12 VS3  
-0.93  
<TS 649 B
54 17 12 VS3  
-0.88  
<TS 650 B
54 17 12 VS3 0.9  
<TS 651 B
54 61 11 05H 0.96  
<TS 652 B
54 69 11 03H 1  
<TS 653 B
54 71 13 02H 0.94  
<TS 654 B
54 103 11 04C 0.81  
<TS 655 B
54 103 12 VS3  
-0.85  
<TS 656 B
54 117 14 02C 0.89  
<TS 657 B
54 121 15 04C  
-0.96  
<TS 658 B
54 143 13 VS3  
-0.87  
<TS 659 B
55 14 12 VS5  
-0.86  
<TS 660 B
55 32 14 VS3  
-0.59  
<TS 661 B
55 54 14 VS3  
-0.75  
<TS 662 B
55 56 11 03H 0.91  
<TS 663 B
55 60 14 04H 0.91  
<TS 108 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 664     B       55       62         13       03C       0.13   <TS 665     B       55       64         17       02C       0.91   <TS 666     B       55       78       13       01C       0.98   <TS 667     B       55       78       11       04H       0.92   <TS 668     B       55       80         9       03H       0.88   <TS 669     B       55       86       11       06C       0.81   <TS 670     B       55       96       10       01C       0.89   <TS 671     B       55       114       17       03C       0.86   <TS 672     B       55       114       11       03C       0.11   <TS 673     B       55       120       14       04H       -0.85   <TS 674     B       55       126       11       03C       0.07   <TS 675     B       55       144       20       VS3       -0.67   <TS 676     B       56       55       12       VS4       -0.71   <TS 677     B       56       59       12       04H       0.87   <TS 678     B       56       77       11       02C       0.81   <TS 679     B       56       77       10       03H       -0.82   <TS 680     B       56       85       21       03C       0.83   <TS 681     B       56       85       14       02C       -0.9   <TS 682     B       56       97         16       04C       0.87   <TS 683     B       56       103       16       DBH       0.24   <TS 684     B       56       129       17       03C       0.82   <TS 685     B       56       129       13       VS3       0.76   <TS 686     B       56       145       17       04C       -0.75   <TS 687     B       56       151       15       06C       0.99   <TS 688     B       56       151         6       06C         0   <TS 689     B       57       16       15       06H       -0.15   <TS 690     B       57       16         8       06H       -1.01   <TS 691     B       57       26       13       06H       0.99   <TS 692     B       57       62         17       04H       0.84   <TS 693     B       57       62         9       02H       -0.88   <TS 694     B       57       62         9       DBC       0.68   <TS 695     B       57       78         9       03H       -0.86   <TS 696     B       57       80         16       03C       0.87   <TS 697     B       57       90         19       03C         0.8   <TS 698     B       57       90         14       03C       -0.89   <TS 699     B       57       118       11       03C       -0.22   <TS 700     B       57       120         8       05C       0.86   <TS 701     B       57       120         9       04C       -0.07   <TS 702     B       57       142       13       VS3       0.76   <TS 109 of 156
Percent No SG Row Column in Depth Location Elevation TS 664 B
55 62 13 03C 0.13  
<TS 665 B
55 64 17 02C 0.91  
<TS 666 B
55 78 13 01C 0.98  
<TS 667 B
55 78 11 04H 0.92  
<TS 668 B
55 80 9
03H 0.88  
<TS 669 B
55 86 11 06C 0.81  
<TS 670 B
55 96 10 01C 0.89  
<TS 671 B
55 114 17 03C 0.86  
<TS 672 B
55 114 11 03C 0.11  
<TS 673 B
55 120 14 04H  
-0.85  
<TS 674 B
55 126 11 03C 0.07  
<TS 675 B
55 144 20 VS3  
-0.67  
<TS 676 B
56 55 12 VS4  
-0.71  
<TS 677 B
56 59 12 04H 0.87  
<TS 678 B
56 77 11 02C 0.81  
<TS 679 B
56 77 10 03H  
-0.82  
<TS 680 B
56 85 21 03C 0.83  
<TS 681 B
56 85 14 02C  
-0.9  
<TS 682 B
56 97 16 04C 0.87  
<TS 683 B
56 103 16 DBH 0.24  
<TS 684 B
56 129 17 03C 0.82  
<TS 685 B
56 129 13 VS3 0.76  
<TS 686 B
56 145 17 04C  
-0.75  
<TS 687 B
56 151 15 06C 0.99  
<TS 688 B
56 151 6
06C 0  
<TS 689 B
57 16 15 06H  
-0.15  
<TS 690 B
57 16 8
06H  
-1.01  
<TS 691 B
57 26 13 06H 0.99  
<TS 692 B
57 62 17 04H 0.84  
<TS 693 B
57 62 9
02H  
-0.88  
<TS 694 B
57 62 9
DBC 0.68  
<TS 695 B
57 78 9
03H  
-0.86  
<TS 696 B
57 80 16 03C 0.87  
<TS 697 B
57 90 19 03C 0.8  
<TS 698 B
57 90 14 03C  
-0.89  
<TS 699 B
57 118 11 03C  
-0.22  
<TS 700 B
57 120 8
05C 0.86  
<TS 701 B
57 120 9
04C  
-0.07  
<TS 702 B
57 142 13 VS3 0.76  
<TS 109 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 703     B       57       142       16       04C       0.82   <TS 704     B       57       144       15       04C         0.8   <TS 705     B       57       144       14       03C       0.76   <TS 706     B       57       146         9       DBH       1.89   <TS 707     B       57       148       16       04C       0.92   <TS 708     B       58       9         10       05H       0.88   <TS 709     B       58       25         11       06H       0.91   <TS 710     B       58       27         18       05H       0.84   <TS 711     B       58       29         12       VS3       -0.87   <TS 712     B       58       47         12       VS5       -1.1   <TS 713     B       58       47         12       03C       -0.88   <TS 714     B       58       57         11       06C       0.75   <TS 715     B       58       59         11       02H       -0.1   <TS 716     B       58       63         12       04H       0.86   <TS 717     B       58       65         10       04H       -0.13   <TS 718     B       58       71         11       04H       -0.81   <TS 719     B       58       71         11       04H       -0.17   <TS 720     B       58       117       13       06C       0.83   <TS 721     B       58       117       13       03C       0.87   <TS 722     B       58       155       12       01C       -0.93   <TS 723     B       59       26         12       04H       0.88   <TS 724     B       59       26         12       03C       0.81   <TS 725     B       59       48         15       06H       0.97   <TS 726     B       59       48         22       03C       0.9   <TS 727     B       59       56         8       03H       0.13   <TS 728     B       59       66         16       02H       -0.83   <TS 729     B       59       70         11       03H       -0.84   <TS 730     B       59       72         16       03H       0.84   <TS 731     B       59       88         12       03C       0.92   <TS 732     B       59       116       11       03C       0.87   <TS 733     B       59       118       14       03C       -0.91   <TS 734     B       59       120       14       04H       -0.91   <TS 735     B       59       120       14       03C       -0.89   <TS 736     B       59       122       13       03C       -0.18   <TS 737     B       60       39         11       04H       0.87   <TS 738     B       60       41         20       02H       -0.06   <TS 739     B       60       63         13       05H       0.98   <TS 740     B       60       63         11       03H       -0.84   <TS 741     B       60       63         8       02H       -0.13   <TS 110 of 156
Percent No SG Row Column in Depth Location Elevation TS 703 B
57 142 16 04C 0.82  
<TS 704 B
57 144 15 04C 0.8  
<TS 705 B
57 144 14 03C 0.76  
<TS 706 B
57 146 9
DBH 1.89  
<TS 707 B
57 148 16 04C 0.92  
<TS 708 B
58 9
10 05H 0.88  
<TS 709 B
58 25 11 06H 0.91  
<TS 710 B
58 27 18 05H 0.84  
<TS 711 B
58 29 12 VS3  
-0.87  
<TS 712 B
58 47 12 VS5  
-1.1  
<TS 713 B
58 47 12 03C  
-0.88  
<TS 714 B
58 57 11 06C 0.75  
<TS 715 B
58 59 11 02H  
-0.1  
<TS 716 B
58 63 12 04H 0.86  
<TS 717 B
58 65 10 04H  
-0.13  
<TS 718 B
58 71 11 04H  
-0.81  
<TS 719 B
58 71 11 04H  
-0.17  
<TS 720 B
58 117 13 06C 0.83  
<TS 721 B
58 117 13 03C 0.87  
<TS 722 B
58 155 12 01C  
-0.93  
<TS 723 B
59 26 12 04H 0.88  
<TS 724 B
59 26 12 03C 0.81  
<TS 725 B
59 48 15 06H 0.97  
<TS 726 B
59 48 22 03C 0.9  
<TS 727 B
59 56 8
03H 0.13  
<TS 728 B
59 66 16 02H  
-0.83  
<TS 729 B
59 70 11 03H  
-0.84  
<TS 730 B
59 72 16 03H 0.84  
<TS 731 B
59 88 12 03C 0.92  
<TS 732 B
59 116 11 03C 0.87  
<TS 733 B
59 118 14 03C  
-0.91  
<TS 734 B
59 120 14 04H  
-0.91  
<TS 735 B
59 120 14 03C  
-0.89  
<TS 736 B
59 122 13 03C  
-0.18  
<TS 737 B
60 39 11 04H 0.87  
<TS 738 B
60 41 20 02H  
-0.06  
<TS 739 B
60 63 13 05H 0.98  
<TS 740 B
60 63 11 03H  
-0.84  
<TS 741 B
60 63 8
02H  
-0.13  
<TS 110 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 742     B       60       71         6       03H       -0.75   <TS 743     B       60       81         12       02H       0.92   <TS 744     B       60       119         13       03C       0.84   <TS 745     B       60       119         15       VS5       -0.87   <TS 746     B       60       133         15       03C       -0.91   <TS 747     B       61       12         15       06H       -0.24   <TS 748     B       61       28         18       DBC         2   <TS 749     B       61       28         13       04H       -0.86   <TS 750     B       61       42         14       VS3       0.89   <TS 751     B       61       48         12       VS3       -1.02   <TS 752     B       61       48         15       03C       0.86   <TS 753     B       61       62         11       03H       -0.81   <TS 754     B       61       68         16       02H       -0.88   <TS 755     B       61       82         12       02C       -0.92   <TS 756     B       61       102         16       05C       -0.11   <TS 757     B       61       114         17       04C       0.83   <TS 758     B       61       120         16       02C       -0.88   <TS 759     B       61       124         13       02C       0.86   <TS 760     B       61       142         15       03C       0.88   <TS 761     B       61       144         15       06H       0.86   <TS 762     B       61       154         16       VS5       1.01   <TS 763     B       61       156         11       01H         0.8   <TS 764     B       62       11         10       04H       0.87   <TS 765     B       62       17         18       VS5       0.91   <TS 766     B       62       17         17       VS4       -0.73   <TS 767     B       62       23         14       VS5       0.93   <TS 768     B       62       39         11       04H       -0.17   <TS 769     B       62       47         15       03C       0.86   <TS 770     B       62       47         10       DBC       -1.04   <TS 771     B       62       53         10       06H         1   <TS 772     B       62       57         14       02H       -0.93   <TS 773     B       62       57         13       02C       0.82   <TS 774     B       62       59         13       02C       0.91   <TS 775     B       62       75         12       03H         0.9   <TS 776     B       62       85         11       DBC       -1.73   <TS 777     B       62       107         13       02C       -0.86   <TS 778     B       62       111         15       03H       0.13   <TS 779     B       62       123         15       DBC       -1.75   <TS 780     B       62       155         12       01H       -0.81   <TS 111 of 156
Percent No SG Row Column in Depth Location Elevation TS 742 B
60 71 6
03H  
-0.75  
<TS 743 B
60 81 12 02H 0.92  
<TS 744 B
60 119 13 03C 0.84  
<TS 745 B
60 119 15 VS5  
-0.87  
<TS 746 B
60 133 15 03C  
-0.91  
<TS 747 B
61 12 15 06H  
-0.24  
<TS 748 B
61 28 18 DBC 2  
<TS 749 B
61 28 13 04H  
-0.86  
<TS 750 B
61 42 14 VS3 0.89  
<TS 751 B
61 48 12 VS3  
-1.02  
<TS 752 B
61 48 15 03C 0.86  
<TS 753 B
61 62 11 03H  
-0.81  
<TS 754 B
61 68 16 02H  
-0.88  
<TS 755 B
61 82 12 02C  
-0.92  
<TS 756 B
61 102 16 05C  
-0.11  
<TS 757 B
61 114 17 04C 0.83  
<TS 758 B
61 120 16 02C  
-0.88  
<TS 759 B
61 124 13 02C 0.86  
<TS 760 B
61 142 15 03C 0.88  
<TS 761 B
61 144 15 06H 0.86  
<TS 762 B
61 154 16 VS5 1.01  
<TS 763 B
61 156 11 01H 0.8  
<TS 764 B
62 11 10 04H 0.87  
<TS 765 B
62 17 18 VS5 0.91  
<TS 766 B
62 17 17 VS4  
-0.73  
<TS 767 B
62 23 14 VS5 0.93  
<TS 768 B
62 39 11 04H  
-0.17  
<TS 769 B
62 47 15 03C 0.86  
<TS 770 B
62 47 10 DBC  
-1.04  
<TS 771 B
62 53 10 06H 1  
<TS 772 B
62 57 14 02H  
-0.93  
<TS 773 B
62 57 13 02C 0.82  
<TS 774 B
62 59 13 02C 0.91  
<TS 775 B
62 75 12 03H 0.9  
<TS 776 B
62 85 11 DBC  
-1.73  
<TS 777 B
62 107 13 02C  
-0.86  
<TS 778 B
62 111 15 03H 0.13  
<TS 779 B
62 123 15 DBC  
-1.75  
<TS 780 B
62 155 12 01H  
-0.81  
<TS 111 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 781     B       62       155         13       01H       -0.1   <TS 782     B       62       155         15       01H       0.84   <TS 783     B       63       18         13       DBC       -0.77   <TS 784     B       63       28         12       06H       -0.97   <TS 785     B       63       42         13       VS3       0.95   <TS 786     B       63       56         14       03H       -0.88   <TS 787     B       63       56         9       04H       -0.89   <TS 788     B       63       56         12       03C       0.84   <TS 789     B       63       58         12       04H       -0.92   <TS 790     B       63       60         12       03C       -0.95   <TS 791     B       63       70         19       04H         0.9   <TS 792     B       63       78         12       03H       -0.82   <TS 793     B       63       82         24       VS4       0.94   <TS 794     B       63       82         12       VS5       -0.28   <TS 795     B       63       82         23       VS5       0.98   <TS 796     B       63       86         11       02C       -0.86   <TS 797     B       63       106         14       03H       0.86   <TS 798     B       63       110         14       03H       -0.13   <TS 799     B       63       114         12       03C       0.11   <TS 800     B       63       114         11       03C       0.86   <TS 801     B       63       124         12       04C       -0.92   <TS 802     B       63       126         11       VS3       0.94   <TS 803     B       63       128         14       06C       0.87   <TS 804     B       63       132         24       VS3         1.1   <TS 805     B       63       136         17       VS5       0.97   <TS 806     B       63       136         17       03C         1   <TS 807     B       63       138         16       03C         1   <TS 808     B       63       140         14       06C       -0.22   <TS 809     B       63       140         16       03C         0.9   <TS 810     B       63       140         10       03C       0.11   <TS 811     B       63       146         13       06C       0.86   <TS 812     B       64       35         10       DBC       -1.9   <TS 813     B       64       37         13       06H       -0.15   <TS 814     B       64       51         17       VS5       -0.04   <TS 815     B       64       51         12       VS5       0.71   <TS 816     B       64       81           5       06H       -0.89   <TS 817     B       64       103         10       04C       0.89   <TS 818     B       64       103         6       04C       -0.93   <TS 819     B       64       111         10       03H       0.92   <TS 112 of 156
Percent No SG Row Column in Depth Location Elevation TS 781 B
62 155 13 01H  
-0.1  
<TS 782 B
62 155 15 01H 0.84  
<TS 783 B
63 18 13 DBC  
-0.77  
<TS 784 B
63 28 12 06H  
-0.97  
<TS 785 B
63 42 13 VS3 0.95  
<TS 786 B
63 56 14 03H  
-0.88  
<TS 787 B
63 56 9
04H  
-0.89  
<TS 788 B
63 56 12 03C 0.84  
<TS 789 B
63 58 12 04H  
-0.92  
<TS 790 B
63 60 12 03C  
-0.95  
<TS 791 B
63 70 19 04H 0.9  
<TS 792 B
63 78 12 03H  
-0.82  
<TS 793 B
63 82 24 VS4 0.94  
<TS 794 B
63 82 12 VS5  
-0.28  
<TS 795 B
63 82 23 VS5 0.98  
<TS 796 B
63 86 11 02C  
-0.86  
<TS 797 B
63 106 14 03H 0.86  
<TS 798 B
63 110 14 03H  
-0.13  
<TS 799 B
63 114 12 03C 0.11  
<TS 800 B
63 114 11 03C 0.86  
<TS 801 B
63 124 12 04C  
-0.92  
<TS 802 B
63 126 11 VS3 0.94  
<TS 803 B
63 128 14 06C 0.87  
<TS 804 B
63 132 24 VS3 1.1  
<TS 805 B
63 136 17 VS5 0.97  
<TS 806 B
63 136 17 03C 1  
<TS 807 B
63 138 16 03C 1  
<TS 808 B
63 140 14 06C  
-0.22  
<TS 809 B
63 140 16 03C 0.9  
<TS 810 B
63 140 10 03C 0.11  
<TS 811 B
63 146 13 06C 0.86  
<TS 812 B
64 35 10 DBC  
-1.9  
<TS 813 B
64 37 13 06H  
-0.15  
<TS 814 B
64 51 17 VS5  
-0.04  
<TS 815 B
64 51 12 VS5 0.71  
<TS 816 B
64 81 5
06H  
-0.89  
<TS 817 B
64 103 10 04C 0.89  
<TS 818 B
64 103 6
04C  
-0.93  
<TS 819 B
64 111 10 03H 0.92  
<TS 112 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 820     B       64       113         10       06C       0.91   <TS 821     B       64       121         14       03C       0.88   <TS 822     B       64       135         14       VS3       -0.89   <TS 823     B       64       135         13       VS4       -0.83   <TS 824     B       64       143         13       06H       0.98   <TS 825     B       64       147         11       DBH       1.78   <TS 826     B       64       153         9       01C       -0.88   <TS 827     B       65       16         11       06H       -0.26   <TS 828     B       65       16         13       VS3       -0.82   <TS 829     B       65       32         13       VS3       -0.86   <TS 830     B       65       62         20       04H       -1.18   <TS 831     B       65       110         21       03H       0.81   <TS 832     B       65       118         15       02C       0.85   <TS 833     B       65       122         14       06C       0.81   <TS 834     B       65       122         12       02C       0.88   <TS 835     B       65       130         11       03C       0.99   <TS 836     B       65       144         12       VS4         0.9   <TS 837     B       65       150         11       DBH       1.98   <TS 838     B       66       17         18       06H       0.91   <TS 839     B       66       17         9       06C       0.77   <TS 840     B       66       21         21       06H       0.89   <TS 841     B       66       27         11       06C       0.82   <TS 842     B       66       27         10       06H       -0.86   <TS 843     B       66       29         12       06C       -0.91   <TS 844     B       66       31         11       06C       0.87   <TS 845     B       66       35         17       06C       0.93   <TS 846     B       66       35         17       DBC       1.31   <TS 847     B       66       39         17       VS5       -0.82   <TS 848     B       66       41         16       VS3       -0.78   <TS 849     B       66       41         12       VS3       -0.2   <TS 850     B       66       41         15       VS4       -0.84   <TS 851     B       66       41         11       DBC       -1.55   <TS 852     B       66       45         14       06C       0.84   <TS 853     B       66       47         11       06C       -0.18   <TS 854     B       66       51         11       06C       0.89   <TS 855     B       66       51         13       04C       -0.15   <TS 856     B       66       51         14       06H       0.89   <TS 857     B       66       59         13       04C       0.95   <TS 858     B       66       77         12       VS3       -0.75   <TS 113 of 156
Percent No SG Row Column in Depth Location Elevation TS 820 B
64 113 10 06C 0.91  
<TS 821 B
64 121 14 03C 0.88  
<TS 822 B
64 135 14 VS3  
-0.89  
<TS 823 B
64 135 13 VS4  
-0.83  
<TS 824 B
64 143 13 06H 0.98  
<TS 825 B
64 147 11 DBH 1.78  
<TS 826 B
64 153 9
01C  
-0.88  
<TS 827 B
65 16 11 06H  
-0.26  
<TS 828 B
65 16 13 VS3  
-0.82  
<TS 829 B
65 32 13 VS3  
-0.86  
<TS 830 B
65 62 20 04H  
-1.18  
<TS 831 B
65 110 21 03H 0.81  
<TS 832 B
65 118 15 02C 0.85  
<TS 833 B
65 122 14 06C 0.81  
<TS 834 B
65 122 12 02C 0.88  
<TS 835 B
65 130 11 03C 0.99  
<TS 836 B
65 144 12 VS4 0.9  
<TS 837 B
65 150 11 DBH 1.98  
<TS 838 B
66 17 18 06H 0.91  
<TS 839 B
66 17 9
06C 0.77  
<TS 840 B
66 21 21 06H 0.89  
<TS 841 B
66 27 11 06C 0.82  
<TS 842 B
66 27 10 06H  
-0.86  
<TS 843 B
66 29 12 06C  
-0.91  
<TS 844 B
66 31 11 06C 0.87  
<TS 845 B
66 35 17 06C 0.93  
<TS 846 B
66 35 17 DBC 1.31  
<TS 847 B
66 39 17 VS5  
-0.82  
<TS 848 B
66 41 16 VS3  
-0.78  
<TS 849 B
66 41 12 VS3  
-0.2  
<TS 850 B
66 41 15 VS4  
-0.84  
<TS 851 B
66 41 11 DBC  
-1.55  
<TS 852 B
66 45 14 06C 0.84  
<TS 853 B
66 47 11 06C  
-0.18  
<TS 854 B
66 51 11 06C 0.89  
<TS 855 B
66 51 13 04C  
-0.15  
<TS 856 B
66 51 14 06H 0.89  
<TS 857 B
66 59 13 04C 0.95  
<TS 858 B
66 77 12 VS3  
-0.75  
<TS 113 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 859     B       66       97         12       01C       0.85   <TS 860     B       66       105       14       VS5       0.85   <TS 861     B       66       107       12       02H       -0.82   <TS 862     B       66       107       10       02C       0.83   <TS 863     B       66       109       23       VS3         0   <TS 864     B       66       125       16       02C       0.94   <TS 865     B       66       137       11       03C         0.9   <TS 866     B       66       137         7       03C       0.11   <TS 867     B       66       143       15       VS5       0.79   <TS 868     B       66       147       17       VS5       -0.62   <TS 869     B       66       147       13       VS3       -0.84   <TS 870     B       66       147       14       VS3       0.84   <TS 871     B       66       149       20       06H       0.83   <TS 872     B       66       153       13       04C       -0.98   <TS 873     B       66       153       18       VS3         0.7   <TS 874     B       67         36       13       06H       0.86   <TS 875     B       67       46         12       DBC       1.63   <TS 876     B       67         52         9       04H       0.88   <TS 877     B       67         56         9       02H         0.9   <TS 878     B       67         56       12       04H       -0.85   <TS 879     B       67         56       13       03C       0.86   <TS 880     B       67         56       12       02C       0.71   <TS 881     B       67         58       18       03C       0.79   <TS 882     B       67         58         9       03C       0.09   <TS 883     B       67       62         18       03C       0.79   <TS 884     B       67       62         14       02C       -0.24   <TS 885     B       67         74         9       04H       -0.86   <TS 886     B       67         76       13       02H       -0.86   <TS 887     B       67         78       11       03H         0.9   <TS 888     B       67       96         13       06C       -0.17   <TS 889     B       67       104       13       03H       0.93   <TS 890     B       67       104       11       04H         0.8   <TS 891     B       67       104       21       06C       -0.15   <TS 892     B       67       108       13       03H       0.93   <TS 893     B       67       112       13       02C       -0.92   <TS 894     B       67       128       21       VS3       0.93   <TS 895     B       67       128       13       06H       0.22   <TS 896     B       67       134       27       06C       -0.97   <TS 897     B       67       134       15       03C       0.88   <TS 114 of 156
Percent No SG Row Column in Depth Location Elevation TS 859 B
66 97 12 01C 0.85  
<TS 860 B
66 105 14 VS5 0.85  
<TS 861 B
66 107 12 02H  
-0.82  
<TS 862 B
66 107 10 02C 0.83  
<TS 863 B
66 109 23 VS3 0  
<TS 864 B
66 125 16 02C 0.94  
<TS 865 B
66 137 11 03C 0.9  
<TS 866 B
66 137 7
03C 0.11  
<TS 867 B
66 143 15 VS5 0.79  
<TS 868 B
66 147 17 VS5  
-0.62  
<TS 869 B
66 147 13 VS3  
-0.84  
<TS 870 B
66 147 14 VS3 0.84  
<TS 871 B
66 149 20 06H 0.83  
<TS 872 B
66 153 13 04C  
-0.98  
<TS 873 B
66 153 18 VS3 0.7  
<TS 874 B
67 36 13 06H 0.86  
<TS 875 B
67 46 12 DBC 1.63  
<TS 876 B
67 52 9
04H 0.88  
<TS 877 B
67 56 9
02H 0.9  
<TS 878 B
67 56 12 04H  
-0.85  
<TS 879 B
67 56 13 03C 0.86  
<TS 880 B
67 56 12 02C 0.71  
<TS 881 B
67 58 18 03C 0.79  
<TS 882 B
67 58 9
03C 0.09  
<TS 883 B
67 62 18 03C 0.79  
<TS 884 B
67 62 14 02C  
-0.24  
<TS 885 B
67 74 9
04H  
-0.86  
<TS 886 B
67 76 13 02H  
-0.86  
<TS 887 B
67 78 11 03H 0.9  
<TS 888 B
67 96 13 06C  
-0.17  
<TS 889 B
67 104 13 03H 0.93  
<TS 890 B
67 104 11 04H 0.8  
<TS 891 B
67 104 21 06C  
-0.15  
<TS 892 B
67 108 13 03H 0.93  
<TS 893 B
67 112 13 02C  
-0.92  
<TS 894 B
67 128 21 VS3 0.93  
<TS 895 B
67 128 13 06H 0.22  
<TS 896 B
67 134 27 06C  
-0.97  
<TS 897 B
67 134 15 03C 0.88  
<TS 114 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 898     B       67       136       19       DBH       -1.64   <TS 899     B       67       138       28       VS3       0.11   <TS 900     B       67       138       29       03C       0.54   <TS 901     B       67       148       19       DBH       1.71   <TS 902     B       67       148       16       VS3       0.77   <TS 903     B       67       150       17       VS3       -0.8   <TS 904     B       67       150       20       VS3       0.91   <TS 905     B       68       17         9       04H       0.92   <TS 906     B       68       21       13       VS5       -0.84   <TS 907     B       68       41         18       04H       0.88   <TS 908     B       68       45         10       DBC       -1.26   <TS 909     B       68       51       10       02H       0.89   <TS 910     B       68       85         13       02C       -0.88   <TS 911     B       68       91         12       03C       -0.88   <TS 912     B       68       93         17       04C       -0.89   <TS 913     B       68       93         12       04C       -0.17   <TS 914     B       68       107       13       02H         0.9   <TS 915     B       68       109       15       02H         0.9   <TS 916     B       68       113       12       03H       0.88   <TS 917     B       68       113         9       04H       -0.92   <TS 918     B       68       113       21       04H         0.9   <TS 919     B       68       117       15       04H       0.97   <TS 920     B       68       139       12       VS3       -0.84   <TS 921     B       68       143       18       06H       0.91   <TS 922     B       68       151       18       VS3       -0.62   <TS 923     B       68       151       16       VS5       0.79   <TS 924     B       69       16       13       VS3       -0.75   <TS 925     B       69       28         14       06H       -0.97   <TS 926     B       69       28         16       06C       0.82   <TS 927     B       69       28         12       06H       -0.15   <TS 928     B       69       32         13       VS4       -0.8   <TS 929     B       69       32         12       VS4       0.86   <TS 930     B       69       34         18       06C       -0.89   <TS 931     B       69       34         16       06C       0.84   <TS 932     B       69       34         20       DBC       1.29   <TS 933     B       69       36         13       04C       0.86   <TS 934     B       69       36         13       DBC         1.5   <TS 935     B       69       48         9       04C       0.13   <TS 936     B       69       52         22       VS3       -0.07   <TS 115 of 156
Percent No SG Row Column in Depth Location Elevation TS 898 B
67 136 19 DBH  
-1.64  
<TS 899 B
67 138 28 VS3 0.11  
<TS 900 B
67 138 29 03C 0.54  
<TS 901 B
67 148 19 DBH 1.71  
<TS 902 B
67 148 16 VS3 0.77  
<TS 903 B
67 150 17 VS3  
-0.8  
<TS 904 B
67 150 20 VS3 0.91  
<TS 905 B
68 17 9
04H 0.92  
<TS 906 B
68 21 13 VS5  
-0.84  
<TS 907 B
68 41 18 04H 0.88  
<TS 908 B
68 45 10 DBC  
-1.26  
<TS 909 B
68 51 10 02H 0.89  
<TS 910 B
68 85 13 02C  
-0.88  
<TS 911 B
68 91 12 03C  
-0.88  
<TS 912 B
68 93 17 04C  
-0.89  
<TS 913 B
68 93 12 04C  
-0.17  
<TS 914 B
68 107 13 02H 0.9  
<TS 915 B
68 109 15 02H 0.9  
<TS 916 B
68 113 12 03H 0.88  
<TS 917 B
68 113 9
04H  
-0.92  
<TS 918 B
68 113 21 04H 0.9  
<TS 919 B
68 117 15 04H 0.97  
<TS 920 B
68 139 12 VS3  
-0.84  
<TS 921 B
68 143 18 06H 0.91  
<TS 922 B
68 151 18 VS3  
-0.62  
<TS 923 B
68 151 16 VS5 0.79  
<TS 924 B
69 16 13 VS3  
-0.75  
<TS 925 B
69 28 14 06H  
-0.97  
<TS 926 B
69 28 16 06C 0.82  
<TS 927 B
69 28 12 06H  
-0.15  
<TS 928 B
69 32 13 VS4  
-0.8  
<TS 929 B
69 32 12 VS4 0.86  
<TS 930 B
69 34 18 06C  
-0.89  
<TS 931 B
69 34 16 06C 0.84  
<TS 932 B
69 34 20 DBC 1.29  
<TS 933 B
69 36 13 04C 0.86  
<TS 934 B
69 36 13 DBC 1.5  
<TS 935 B
69 48 9
04C 0.13  
<TS 936 B
69 52 22 VS3  
-0.07  
<TS 115 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 937     B       69       52         16       VS5       -0.78   <TS 938     B       69       52         19       VS5         0.8   <TS 939     B       69       52         23       VS4       -0.73   <TS 940     B       69       52         15       VS4       -0.09   <TS 941     B       69       56         15       VS3       0.75   <TS 942     B       69       56         8       VS3       0.13   <TS 943     B       69       56         14       VS5       -0.78   <TS 944     B       69       56         13       VS5       0.73   <TS 945     B       69       66         13       02H       0.92   <TS 946     B       69       72         15       06C       -0.95   <TS 947     B       69       76         16       VS5       0.99   <TS 948     B       69       102         10       03H         0.8   <TS 949     B       69       106         16       06H       -0.87   <TS 950     B       69       110         15       03C       0.94   <TS 951     B       69       114         17       04H       0.88   <TS 952     B       69       120         17       03C       0.88   <TS 953     B       69       120         13       03C       0.09   <TS 954     B       69       122         9       04H       0.95   <TS 955     B       69       124         11       03C       -0.92   <TS 956     B       69       126         17       03H       0.92   <TS 957     B       69       128         21       03C       0.92   <TS 958     B       69       132         16       04H       0.98   <TS 959     B       69       134         16       VS3       -0.83   <TS 960     B       69       134         35       VS4       -0.9   <TS 961     B       69       134         28       VS4       0.97   <TS 962     B       69       134         15       VS5       -0.83   <TS 963     B       69       134         15       VS5         0.7   <TS 964     B       69       136         18       VS5       -0.79   <TS 965     B       69       136         13       VS5       0.82   <TS 966     B       69       140         14       VS3       0.84   <TS 967     B       69       140         15       VS4       0.88   <TS 968     B       69       140         20       VS5       -0.79   <TS 969     B       69       140         16       VS5       0.86   <TS 970     B       69       144         19       VS3       -0.86   <TS 971     B       69       144         26       VS5       -0.81   <TS 972     B       69       150         30       VS3       -0.86   <TS 973     B       69       150         23       VS3       0.83   <TS 974     B       69       150         13       VS4       1.03   <TS 975     B       69       150         23       VS5       0.79   <TS 116 of 156
Percent No SG Row Column in Depth Location Elevation TS 937 B
69 52 16 VS5  
-0.78  
<TS 938 B
69 52 19 VS5 0.8  
<TS 939 B
69 52 23 VS4  
-0.73  
<TS 940 B
69 52 15 VS4  
-0.09  
<TS 941 B
69 56 15 VS3 0.75  
<TS 942 B
69 56 8
VS3 0.13  
<TS 943 B
69 56 14 VS5  
-0.78  
<TS 944 B
69 56 13 VS5 0.73  
<TS 945 B
69 66 13 02H 0.92  
<TS 946 B
69 72 15 06C  
-0.95  
<TS 947 B
69 76 16 VS5 0.99  
<TS 948 B
69 102 10 03H 0.8  
<TS 949 B
69 106 16 06H  
-0.87  
<TS 950 B
69 110 15 03C 0.94  
<TS 951 B
69 114 17 04H 0.88  
<TS 952 B
69 120 17 03C 0.88  
<TS 953 B
69 120 13 03C 0.09  
<TS 954 B
69 122 9
04H 0.95  
<TS 955 B
69 124 11 03C  
-0.92  
<TS 956 B
69 126 17 03H 0.92  
<TS 957 B
69 128 21 03C 0.92  
<TS 958 B
69 132 16 04H 0.98  
<TS 959 B
69 134 16 VS3  
-0.83  
<TS 960 B
69 134 35 VS4  
-0.9  
<TS 961 B
69 134 28 VS4 0.97  
<TS 962 B
69 134 15 VS5  
-0.83  
<TS 963 B
69 134 15 VS5 0.7  
<TS 964 B
69 136 18 VS5  
-0.79  
<TS 965 B
69 136 13 VS5 0.82  
<TS 966 B
69 140 14 VS3 0.84  
<TS 967 B
69 140 15 VS4 0.88  
<TS 968 B
69 140 20 VS5  
-0.79  
<TS 969 B
69 140 16 VS5 0.86  
<TS 970 B
69 144 19 VS3  
-0.86  
<TS 971 B
69 144 26 VS5  
-0.81  
<TS 972 B
69 150 30 VS3  
-0.86  
<TS 973 B
69 150 23 VS3 0.83  
<TS 974 B
69 150 13 VS4 1.03  
<TS 975 B
69 150 23 VS5 0.79  
<TS 116 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 976   B       70       31         12       06C       0.89   <TS 977   B       70       45         14       03H       0.92   <TS 978   B       70       47         11       04C       0.02   <TS 979   B       70       51         15       03C       0.88   <TS 980   B       70       75         18       03H       -0.5   <TS 981   B       70       83         11       02C       0.84   <TS 982   B       70       107       12       02H       -0.88   <TS 983   B       70       115       14       04H       0.95   <TS 984   B       70       117       12       03C       -0.93   <TS 985   B       70       129       21       06C       -0.93   <TS 986   B       70       141       21       VS3       -0.86   <TS 987   B       70       143       11       DBC         1.3   <TS 988   B       70       147       15       VS3       -0.89   <TS 989   B       70       153       16       VS4       -0.94   <TS 990   B       70       153       17       VS4       0.97   <TS 991   B       70       153       19       03C       0.15   <TS 992   B       71       14       16       VS4       0.97   <TS 993   B       71       14       12       02H       -0.87   <TS 994   B       71       20         17       DBH       -1.57   <TS 995   B       71       20         17       VS5       0.88   <TS 996   B       71       20         16       DBC       1.46   <TS 997   B       71       36         16       VS3       0.09   <TS 998   B       71       36         17       VS3       0.82   <TS 999   B       71       36         19       VS4         0.8   <TS 1000   B       71       36         14       VS5       -0.69   <TS 1001   B       71       36         26       VS5       0.02   <TS 1002   B       71       36         9       DBC         2   <TS 1003   B       71       36         11       DBC         -2   <TS 1004   B       71       36         9       VS4       -0.83   <TS 1005   B       71       38         16       05H       0.99   <TS 1006   B       71       42         9       04H       -0.79   <TS 1007   B       71       46         13       04H       -0.85   <TS 1008   B       71       52         13       03C       0.88   <TS 1009   B       71       52         8       02C       -0.9   <TS 1010   B       71       58         11       02C       -0.09   <TS 1011   B       71       62         14       03C       -0.22   <TS 1012   B       71       62         10       02C       -0.22   <TS 1013   B       71       80         9       03C       0.13   <TS 1014   B       71       86         15       VS5       -0.84   <TS 117 of 156
Percent No SG Row Column in Depth Location Elevation TS 976 B
70 31 12 06C 0.89  
<TS 977 B
70 45 14 03H 0.92  
<TS 978 B
70 47 11 04C 0.02  
<TS 979 B
70 51 15 03C 0.88  
<TS 980 B
70 75 18 03H  
-0.5  
<TS 981 B
70 83 11 02C 0.84  
<TS 982 B
70 107 12 02H  
-0.88  
<TS 983 B
70 115 14 04H 0.95  
<TS 984 B
70 117 12 03C  
-0.93  
<TS 985 B
70 129 21 06C  
-0.93  
<TS 986 B
70 141 21 VS3  
-0.86  
<TS 987 B
70 143 11 DBC 1.3  
<TS 988 B
70 147 15 VS3  
-0.89  
<TS 989 B
70 153 16 VS4  
-0.94  
<TS 990 B
70 153 17 VS4 0.97  
<TS 991 B
70 153 19 03C 0.15  
<TS 992 B
71 14 16 VS4 0.97  
<TS 993 B
71 14 12 02H  
-0.87  
<TS 994 B
71 20 17 DBH  
-1.57  
<TS 995 B
71 20 17 VS5 0.88  
<TS 996 B
71 20 16 DBC 1.46  
<TS 997 B
71 36 16 VS3 0.09  
<TS 998 B
71 36 17 VS3 0.82  
<TS 999 B
71 36 19 VS4 0.8  
<TS 1000 B
71 36 14 VS5  
-0.69  
<TS 1001 B
71 36 26 VS5 0.02  
<TS 1002 B
71 36 9
DBC 2  
<TS 1003 B
71 36 11 DBC  
-2  
<TS 1004 B
71 36 9
VS4  
-0.83  
<TS 1005 B
71 38 16 05H 0.99  
<TS 1006 B
71 42 9
04H  
-0.79  
<TS 1007 B
71 46 13 04H  
-0.85  
<TS 1008 B
71 52 13 03C 0.88  
<TS 1009 B
71 52 8
02C  
-0.9  
<TS 1010 B
71 58 11 02C  
-0.09  
<TS 1011 B
71 62 14 03C  
-0.22  
<TS 1012 B
71 62 10 02C  
-0.22  
<TS 1013 B
71 80 9
03C 0.13  
<TS 1014 B
71 86 15 VS5  
-0.84  
<TS 117 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1015   B       71       86         10       02C       -0.13   <TS 1016   B       71       86         15       02C       -0.83   <TS 1017   B       71       102       12       05C       0.85   <TS 1018   B       71       104       13       02H       0.82   <TS 1019   B       71       110       12       04H       -0.77   <TS 1020   B       71       112       11       04C       0.84   <TS 1021   B       71       114       10       02C       -0.9   <TS 1022   B       71       116         8       03C       -0.89   <TS 1023   B       71       118         9       020       -0.13   <TS 1024   B       71       132       16       VS5       0.86   <TS 1025   B       71       136       14       060       -0.07   <TS 1026   B       71       136       22       06C       -0.9   <TS 1027   B       71       142       10       06H       -1.06   <TS 1028   B       71       142       11       DBC         0.9   <TS 1029   B       71       144       28       VS3       -0.93   <TS 1030   B       71       144       17       VS3       0.95   <TS 1031   B       71       144       16       DBC       1.63   <TS 1032   B       71       144       14       DBH       1.79   <TS 1033   B       71       146       14       06H       0.22   <TS 1034   B       71       146       10       VS3       0.24   <TS 1035   B       71       146       20       VS4       0.88   <TS 1036   B       71       146       30       VS5       -0.79   <TS 1037   B       71       152       16       VS5       0.86   <TS 1038   B       71       152       10       VS4       0.86   <TS 1039   B       72       17       21       DBH       1.53   <TS 1040   B       72       19       13       VS3       0.15   <TS 1041   B       72       23         13       VS3       0.7   <TS 1042   B       72       25         20       VS3       -0.86   <TS 1043   B       72       25         10       VS3       -0.13   <TS 1044   B       72       41         23       060       0.89   <TS 1045   B       72       47         11       030       -0.93   <TS 1046   B       72       49         27       030       0.95   <TS 1047   B       72       55         15       VS3       -0.99   <TS 1048   B       72       57         10       03C       -0.8   <TS 1049   B       72       59         15       04C       0.82   <TS 1050   B       72       61         16       020       0.81   <TS 1051   B       72       63         12       020       0.85   <TS 1052   B       72       85         14       05C       0.84   <TS 1053   B       72       91         11       02C       0.88   <TS 118 of 156
Percent No SG Row Column in Depth Location Elevation TS 1015 B
71 86 10 02C  
-0.13  
<TS 1016 B
71 86 15 02C  
-0.83  
<TS 1017 B
71 102 12 05C 0.85  
<TS 1018 B
71 104 13 02H 0.82  
<TS 1019 B
71 110 12 04H  
-0.77  
<TS 1020 B
71 112 11 04C 0.84  
<TS 1021 B
71 114 10 02C  
-0.9  
<TS 1022 B
71 116 8
03C  
-0.89  
<TS 1023 B
71 118 9
020  
-0.13  
<TS 1024 B
71 132 16 VS5 0.86  
<TS 1025 B
71 136 14 060  
-0.07  
<TS 1026 B
71 136 22 06C  
-0.9  
<TS 1027 B
71 142 10 06H  
-1.06  
<TS 1028 B
71 142 11 DBC 0.9  
<TS 1029 B
71 144 28 VS3  
-0.93  
<TS 1030 B
71 144 17 VS3 0.95  
<TS 1031 B
71 144 16 DBC 1.63  
<TS 1032 B
71 144 14 DBH 1.79  
<TS 1033 B
71 146 14 06H 0.22  
<TS 1034 B
71 146 10 VS3 0.24  
<TS 1035 B
71 146 20 VS4 0.88  
<TS 1036 B
71 146 30 VS5  
-0.79  
<TS 1037 B
71 152 16 VS5 0.86  
<TS 1038 B
71 152 10 VS4 0.86  
<TS 1039 B
72 17 21 DBH 1.53  
<TS 1040 B
72 19 13 VS3 0.15  
<TS 1041 B
72 23 13 VS3 0.7  
<TS 1042 B
72 25 20 VS3  
-0.86  
<TS 1043 B
72 25 10 VS3  
-0.13  
<TS 1044 B
72 41 23 060 0.89  
<TS 1045 B
72 47 11 030  
-0.93  
<TS 1046 B
72 49 27 030 0.95  
<TS 1047 B
72 55 15 VS3  
-0.99  
<TS 1048 B
72 57 10 03C  
-0.8  
<TS 1049 B
72 59 15 04C 0.82  
<TS 1050 B
72 61 16 020 0.81  
<TS 1051 B
72 63 12 020 0.85  
<TS 1052 B
72 85 14 05C 0.84  
<TS 1053 B
72 91 11 02C 0.88  
<TS 118 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1054   B       72       109         13       02H       0.86   <TS 1055   B       72       109         14       03H       -0.9   <TS 1056   B       72       113         13       02H       -0.88   <TS 1057   B       72       113         9       02H         0.9   <TS 1058   B       72       113         11       04H       0.82   <TS 1059   B       72       113         12       04C       0.88   <TS 1060   B       72       125         22       06C       0.92   <TS 1061   B       72       129         18       VS5       -0.82   <TS 1062   B       72       139         10       VS3       0.87   <TS 1063   B       72       149         18       VS3       0.93   <TS 1064   B       72       149         26       DBH       1.79   <TS 1065   B       73       14         11       VS4       0.26   <TS 1066   B       73       14         10       VS4       -0.99   <TS 1067   B       73       20         16       VS5         0.8   <TS 1068   B       73       40         9       05H       1.01   <TS 1069   B       73       46         8       04C       -0.91   <TS 1070   B       73       58         12       02C       -0.18   <TS 1071   B       73       58         14       06C       -0.2   <TS 1072   B       73       86         13       02C       -0.9   <TS 1073   B       73       104         18       06C       -0.96   <TS 1074   B       73       106         12       03H       0.92   <TS 1075   B       73       132         13       06H       0.88   <TS 1076   B       73       152         10       VS4       -1.03   <TS 1077   B       73       152         8       VS4       0.33   <TS 1078   B       74       17         30       VS3       -0.89   <TS 1079   B       74       17         16       VS3       0.89   <TS 1080   B       74       17         28       VS4       -0.97   <TS 1081   B       74       19         12       DBC       -1.33   <TS 1082   B       74       19         15       VS4       -0.95   <TS 1083   B       74       21         12       VS3       1.18   <TS 1084   B       74       23         21       VS3       -1.01   <TS 1085   B       74       23         20       VS4       -0.89   <TS 1086   B       74       23         20       DBC         1.2   <TS 1087   B       74       29         13       05H       0.95   <TS 1088   B       74       35         17       DBH       1.38   <TS 1089   B       74       37         14       06H       0.93   <TS 1090   B       74       37         13       04C       -0.89   <TS 1091   B       74       37         11       DBC       1.49   <TS 1092   B       74       43         14       VS3       -0.84   <TS 119 of 156
Percent No SG Row Column in Depth Location Elevation TS 1054 B
72 109 13 02H 0.86  
<TS 1055 B
72 109 14 03H  
-0.9  
<TS 1056 B
72 113 13 02H  
-0.88  
<TS 1057 B
72 113 9
02H 0.9  
<TS 1058 B
72 113 11 04H 0.82  
<TS 1059 B
72 113 12 04C 0.88  
<TS 1060 B
72 125 22 06C 0.92  
<TS 1061 B
72 129 18 VS5  
-0.82  
<TS 1062 B
72 139 10 VS3 0.87  
<TS 1063 B
72 149 18 VS3 0.93  
<TS 1064 B
72 149 26 DBH 1.79  
<TS 1065 B
73 14 11 VS4 0.26  
<TS 1066 B
73 14 10 VS4  
-0.99  
<TS 1067 B
73 20 16 VS5 0.8  
<TS 1068 B
73 40 9
05H 1.01  
<TS 1069 B
73 46 8
04C  
-0.91  
<TS 1070 B
73 58 12 02C  
-0.18  
<TS 1071 B
73 58 14 06C  
-0.2  
<TS 1072 B
73 86 13 02C  
-0.9  
<TS 1073 B
73 104 18 06C  
-0.96  
<TS 1074 B
73 106 12 03H 0.92  
<TS 1075 B
73 132 13 06H 0.88  
<TS 1076 B
73 152 10 VS4  
-1.03  
<TS 1077 B
73 152 8
VS4 0.33  
<TS 1078 B
74 17 30 VS3  
-0.89  
<TS 1079 B
74 17 16 VS3 0.89  
<TS 1080 B
74 17 28 VS4  
-0.97  
<TS 1081 B
74 19 12 DBC  
-1.33  
<TS 1082 B
74 19 15 VS4  
-0.95  
<TS 1083 B
74 21 12 VS3 1.18  
<TS 1084 B
74 23 21 VS3  
-1.01  
<TS 1085 B
74 23 20 VS4  
-0.89  
<TS 1086 B
74 23 20 DBC 1.2  
<TS 1087 B
74 29 13 05H 0.95  
<TS 1088 B
74 35 17 DBH 1.38  
<TS 1089 B
74 37 14 06H 0.93  
<TS 1090 B
74 37 13 04C  
-0.89  
<TS 1091 B
74 37 11 DBC 1.49  
<TS 1092 B
74 43 14 VS3  
-0.84  
<TS 119 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1093   B       74       43         20       VS4       -0.8   <TS 1094   B       74       45         20       VS5       -0.77   <TS 1095   B       74       47         9       06C       0.09   <TS 1096   B       74       51         11       03C       -0.89   <TS 1097   B       74       53         11       VS3       -0.8   <TS 1098   B       74       55         20       04C       0.84   <TS 1099   B       74       55         14       04C       -0.97   <TS 1100   B       74       71         13       03H       0.92   <TS 1101   B       74       75         15       VS4       -0.64   <TS 1102   B       74       107         14       04H       -0.94   <TS 1103   B       74       111         16       02C       -0.9   <TS 1104   B       74       115         11       04C       0.91   <TS 1105   B       74       117         10       VS4       -0.77   <TS 1106   B       74       117         14       VS3       -1.1   <TS 1107   B       74       119         16       03H       0.81   <TS 1108   B       74       119         19       04H         1   <TS 1109   B       74       127         21       DBH       -1.49   <TS 1110   B       74       141         19       VS5       -0.7   <TS 1111   B       74       151         11       VS3       -0.9   <TS 1112   B       75       16         13       02H       0.88   <TS 1113   B       75       16         13       06H         0.9   <TS 1114   B       75       24         16       VS3         0.8   <TS 1115   B       75       24         15       VS3       0.15   <TS 1116   B       75       24         12       VS4       0.77   <TS 1117   B       75       24         14       DBC       -1.38   <TS 1118   B       75       36         18       VS3         0.8   <TS 1119   B       75       42         17       04C       0.86   <TS 1120   B       75       54         10       04C       0.88   <TS 1121   B       75       60         14       03C       0.82   <TS 1122   B       75       84         15       020       -0.83   <TS 1123   B       75       84           8       02C       0.83   <TS 1124   B       75       102         13       04H       0.89   <TS 1125   B       75       104         18       03H       0.91   <TS 1126   B       75       106         13       02H       -0.92   <TS 1127   B       75       106         10       05H       -0.81   <TS 1128   B       75       106         13       04C       -0.88   <TS 1129   B       75       110         13       04C       -0.92   <TS 1130   B       75       112         9       03H       -0.83   <TS 1131   B       75       132         12       06H       -0.88   <TS 120 of 156
Percent No SG Row Column in Depth Location Elevation TS 1093 B
74 43 20 VS4  
-0.8  
<TS 1094 B
74 45 20 VS5  
-0.77  
<TS 1095 B
74 47 9
06C 0.09  
<TS 1096 B
74 51 11 03C  
-0.89  
<TS 1097 B
74 53 11 VS3  
-0.8  
<TS 1098 B
74 55 20 04C 0.84  
<TS 1099 B
74 55 14 04C  
-0.97  
<TS 1100 B
74 71 13 03H 0.92  
<TS 1101 B
74 75 15 VS4  
-0.64  
<TS 1102 B
74 107 14 04H  
-0.94  
<TS 1103 B
74 111 16 02C  
-0.9  
<TS 1104 B
74 115 11 04C 0.91  
<TS 1105 B
74 117 10 VS4  
-0.77  
<TS 1106 B
74 117 14 VS3  
-1.1  
<TS 1107 B
74 119 16 03H 0.81  
<TS 1108 B
74 119 19 04H 1  
<TS 1109 B
74 127 21 DBH  
-1.49  
<TS 1110 B
74 141 19 VS5  
-0.7  
<TS 1111 B
74 151 11 VS3  
-0.9  
<TS 1112 B
75 16 13 02H 0.88  
<TS 1113 B
75 16 13 06H 0.9  
<TS 1114 B
75 24 16 VS3 0.8  
<TS 1115 B
75 24 15 VS3 0.15  
<TS 1116 B
75 24 12 VS4 0.77  
<TS 1117 B
75 24 14 DBC  
-1.38  
<TS 1118 B
75 36 18 VS3 0.8  
<TS 1119 B
75 42 17 04C 0.86  
<TS 1120 B
75 54 10 04C 0.88  
<TS 1121 B
75 60 14 03C 0.82  
<TS 1122 B
75 84 15 020  
-0.83  
<TS 1123 B
75 84 8
02C 0.83  
<TS 1124 B
75 102 13 04H 0.89  
<TS 1125 B
75 104 18 03H 0.91  
<TS 1126 B
75 106 13 02H  
-0.92  
<TS 1127 B
75 106 10 05H  
-0.81  
<TS 1128 B
75 106 13 04C  
-0.88  
<TS 1129 B
75 110 13 04C  
-0.92  
<TS 1130 B
75 112 9
03H  
-0.83  
<TS 1131 B
75 132 12 06H  
-0.88  
<TS 120 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1132   B       75       132         10       DBH       -1.76   <TS 1133   B       75       142         10       DBC       1.01   <TS 1134   B       75       150         15       040       0.91   <TS 1135   B       76       15         22       DBH       1.92   <TS 1136   B       76       21         13       VS3       1.04   <TS 1137   B       76       21         14       VS4       -0.84   <TS 1138   B       76       21         26       VS4         0.9   <TS 1139   B       76       25         12       06H       0.95   <TS 1140   B       76       27         8       06H       -0.88   <TS 1141   B       76       29         10       DBC       1.31   <TS 1142   B       76       29         22       VS4       0.04   <TS 1143   B       76       29         19       VS3       0.64   <TS 1144   B       76       29         20       VS3       0.09   <TS 1145   B       76       29         14       VS3       -0.82   <TS 1146   B       76       33         17       DBH       2.06   <TS 1147   B       76       35         19       DBH         1.7   <TS 1148   B       76       41         11       03C       -0.09   <TS 1149   B       76       41         10       05C       -0.95   <TS 1150   B       76       51         19       VS3       1.04   <TS 1151   B       76       53         8       03C       -0.13   <TS 1152   B       76       55         14       DBH       1.63   <TS 1153   B       76       59         12       05H       1.03   <TS 1154   B       76       59         15       VS3       -0.86   <TS 1155   B       76       65         11       VS4       -0.18   <TS 1156   B       76       73           8       02H       -0.08   <TS 1157   B       76       111         11       04C       0.84   <TS 1158   B       76       113         8       04H       0.17   <TS 1159   B       76       115         7       03H       -0.15   <TS 1160   B       76       117         11       DBC         -1   <TS 1161   B       76       121         16       040       0.86   <TS 1162   B       76       123         9       03H       0.89   <TS 1163   B       76       127         11       DBH       -1.63   <TS 1164   B       76       135         13       VS5       0.83   <TS 1165   B       76       141         27       DBH       1.78   <TS 1166   B       76       151         14       04C       0.88   <TS 1167   B       77       34         12       VS3       0.09   <TS 1168   B       77       34         24       VS3       0.78   <TS 1169   B       77       48         16       VS4       0.95   <TS 1170   B       77       50         13       05H       -0.99   <TS 121 of 156
Percent No SG Row Column in Depth Location Elevation TS 1132 B
75 132 10 DBH  
-1.76  
<TS 1133 B
75 142 10 DBC 1.01  
<TS 1134 B
75 150 15 040 0.91  
<TS 1135 B
76 15 22 DBH 1.92  
<TS 1136 B
76 21 13 VS3 1.04  
<TS 1137 B
76 21 14 VS4  
-0.84  
<TS 1138 B
76 21 26 VS4 0.9  
<TS 1139 B
76 25 12 06H 0.95  
<TS 1140 B
76 27 8
06H  
-0.88  
<TS 1141 B
76 29 10 DBC 1.31  
<TS 1142 B
76 29 22 VS4 0.04  
<TS 1143 B
76 29 19 VS3 0.64  
<TS 1144 B
76 29 20 VS3 0.09  
<TS 1145 B
76 29 14 VS3  
-0.82  
<TS 1146 B
76 33 17 DBH 2.06  
<TS 1147 B
76 35 19 DBH 1.7  
<TS 1148 B
76 41 11 03C  
-0.09  
<TS 1149 B
76 41 10 05C  
-0.95  
<TS 1150 B
76 51 19 VS3 1.04  
<TS 1151 B
76 53 8
03C  
-0.13  
<TS 1152 B
76 55 14 DBH 1.63  
<TS 1153 B
76 59 12 05H 1.03  
<TS 1154 B
76 59 15 VS3  
-0.86  
<TS 1155 B
76 65 11 VS4  
-0.18  
<TS 1156 B
76 73 8
02H  
-0.08  
<TS 1157 B
76 111 11 04C 0.84  
<TS 1158 B
76 113 8
04H 0.17  
<TS 1159 B
76 115 7
03H  
-0.15  
<TS 1160 B
76 117 11 DBC  
-1  
<TS 1161 B
76 121 16 040 0.86  
<TS 1162 B
76 123 9
03H 0.89  
<TS 1163 B
76 127 11 DBH  
-1.63  
<TS 1164 B
76 135 13 VS5 0.83  
<TS 1165 B
76 141 27 DBH 1.78  
<TS 1166 B
76 151 14 04C 0.88  
<TS 1167 B
77 34 12 VS3 0.09  
<TS 1168 B
77 34 24 VS3 0.78  
<TS 1169 B
77 48 16 VS4 0.95  
<TS 1170 B
77 50 13 05H  
-0.99  
<TS 121 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1171   B       77       56       10       DBH       1.13   <TS 1172   B       77       86         15       02C       0.83   <TS 1173   B       77       86         8       02C       -0.92   <TS 1174   B       77       104       20       05H       0.87   <TS 1175   B       77       104       20       05C       0.85   <TS 1176   B       77       116       17       04H       -0.92   <TS 1177   B       77       122       13       03H       0.87   <TS 1178   B       77       150       18       DBH       1.43   <TS 1179   B       77       150       13       VS3       -0.79   <TS 1180   B       77       150       18       VS4       -0.88   <TS 1181   B       77       150       24       VS4         0.9   <TS 1182   B       78       23         20       DBH       -1.51   <TS 1183   B       78       33         16       03C       0.89   <TS 1184   B       78       35         16       DBH       -1.18   <TS 1185   B       78       47         20       02C       0.89   <TS 1186   B       78       57         21       03C       0.92   <TS 1187   B       78       61         22       VS3       -0.92   <TS 1188   B       78       79         13       VS4       0.91   <TS 1189   B       78       81         11       03H       0.89   <TS 1190   B       78       87         13       03C       -0.83   <TS 1191   B       78       91         17       07H       1.52   <TS 1192   B       78       105       12       02H       -0.89   <TS 1193   B       78       109       11       02H       -0.81   <TS 1194   B       78       109       11       03H       0.15   <TS 1195   B       78       109       15       03H       0.87   <TS 1196   B       78       137       13       04C       -0.9   <TS 1197   B       78       139       12       DBH       1.76   <TS 1198   B       78       141       12       VS3       -0.86   <TS 1199   B       78       141       10       VS4       -0.77   <TS 1200   B       78       145       14       VS5       0.13   <TS 1201   B       79       24         15       VS3       -0.78   <TS 1202   B       79       24         15       VS3       0.92   <TS 1203   B       79       24         28       VS4         0   <TS 1204   B       79       24         30       VS4       0.74   <TS 1205   B       79       30         11       DBC       1.56   <TS 1206   B       79       44         10       04C       -0.86   <TS 1207   B       79       44         12       03C       0.86   <TS 1208   B       79       52         13       02C       -0.26   <TS 1209   B       79       54         12       03C       0.82   <TS 122 of 156
Percent No SG Row Column in Depth Location Elevation TS 1171 B
77 56 10 DBH 1.13  
<TS 1172 B
77 86 15 02C 0.83  
<TS 1173 B
77 86 8
02C  
-0.92  
<TS 1174 B
77 104 20 05H 0.87  
<TS 1175 B
77 104 20 05C 0.85  
<TS 1176 B
77 116 17 04H  
-0.92  
<TS 1177 B
77 122 13 03H 0.87  
<TS 1178 B
77 150 18 DBH 1.43  
<TS 1179 B
77 150 13 VS3  
-0.79  
<TS 1180 B
77 150 18 VS4  
-0.88  
<TS 1181 B
77 150 24 VS4 0.9  
<TS 1182 B
78 23 20 DBH  
-1.51  
<TS 1183 B
78 33 16 03C 0.89  
<TS 1184 B
78 35 16 DBH  
-1.18  
<TS 1185 B
78 47 20 02C 0.89  
<TS 1186 B
78 57 21 03C 0.92  
<TS 1187 B
78 61 22 VS3  
-0.92  
<TS 1188 B
78 79 13 VS4 0.91  
<TS 1189 B
78 81 11 03H 0.89  
<TS 1190 B
78 87 13 03C  
-0.83  
<TS 1191 B
78 91 17 07H 1.52  
<TS 1192 B
78 105 12 02H  
-0.89  
<TS 1193 B
78 109 11 02H  
-0.81  
<TS 1194 B
78 109 11 03H 0.15  
<TS 1195 B
78 109 15 03H 0.87  
<TS 1196 B
78 137 13 04C  
-0.9  
<TS 1197 B
78 139 12 DBH 1.76  
<TS 1198 B
78 141 12 VS3  
-0.86  
<TS 1199 B
78 141 10 VS4  
-0.77  
<TS 1200 B
78 145 14 VS5 0.13  
<TS 1201 B
79 24 15 VS3  
-0.78  
<TS 1202 B
79 24 15 VS3 0.92  
<TS 1203 B
79 24 28 VS4 0  
<TS 1204 B
79 24 30 VS4 0.74  
<TS 1205 B
79 30 11 DBC 1.56  
<TS 1206 B
79 44 10 04C  
-0.86  
<TS 1207 B
79 44 12 03C 0.86  
<TS 1208 B
79 52 13 02C  
-0.26  
<TS 1209 B
79 54 12 03C 0.82  
<TS 122 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1210   B       79       60       12       03C       -0.95   <TS 1211   B       79       62       12       04C       -0.96   <TS 1212   B       79       62         11       02C       -0.2   <TS 1213   B       79       78       10       VS5       0.86   <TS 1214   B       79       86         14       03H       0.84   <TS 1215   B       79       86         12       03C       0.86   <TS 1216   B       79       108       15       05H       0.74   <TS 1217   B       79       122       20       03H       1.02   <TS 1218   B       79       128       13       03C       0.86   <TS 1219   B       79       150       10       03C       -0.9   <TS 1220   B       80       17       30       DBH       1.59   <TS 1221   B       80       49         15       VS3       -0.82   <TS 1222   B       80       49         13       VS4       -0.77   <TS 1223   B       80       95         12       02H       0.82   <TS 1224   B       80       95         16       03H       0.87   <TS 1225   B       80       95         18       04H       0.88   <TS 1226   B       80       97         14       VS3       -0.2   <TS 1227   B       80       115       14       VS3       0.91   <TS 1228   B       80       115       19       VS4       -0.87   <TS 1229   B       80       129       13       03H         0.9   <TS 1230   B       80       145       29       VS4       -0.73   <TS 1231   B       80       145       16       VS5       0.84   <TS 1232   B       80       145       12       VS5       -0.89   <TS 1233   B       80       149       15       01H       -0.84   <TS 1234   B       81       22         29       VS3       0.89   <TS 1235   B       81       22         28       VS4       0.8   <TS 1236   B       81       24         16       VS3       -0.85   <TS 1237   B       81       24         13       VS3       0.89   <TS 1238   B       81       52         31       VS3       0.84   <TS 1239   B       81       60         15       03C       0.81   <TS 1240   B       81       92         13       02C       -0.88   <TS 1241   B       81       110       12       03H       0.88   <TS 1242   B       81       112       16       02H       0.9   <TS 1243   B       81       114       14       03H       0.81   <TS 1244   B       81       124       12       03C       -0.86   <TS 1245   B       81       126       20       07C       0.77   <TS 1246   B       81       148       15       VS4       -0.86   <TS 1247   B       81       148       17       VS4       0.9   <TS 1248   B       81       148       17       04C       0.88   <TS 123 of 156
Percent No SG Row Column in Depth Location Elevation TS 1210 B
79 60 12 03C  
-0.95  
<TS 1211 B
79 62 12 04C  
-0.96  
<TS 1212 B
79 62 11 02C  
-0.2  
<TS 1213 B
79 78 10 VS5 0.86  
<TS 1214 B
79 86 14 03H 0.84  
<TS 1215 B
79 86 12 03C 0.86  
<TS 1216 B
79 108 15 05H 0.74  
<TS 1217 B
79 122 20 03H 1.02  
<TS 1218 B
79 128 13 03C 0.86  
<TS 1219 B
79 150 10 03C  
-0.9  
<TS 1220 B
80 17 30 DBH 1.59  
<TS 1221 B
80 49 15 VS3  
-0.82  
<TS 1222 B
80 49 13 VS4  
-0.77  
<TS 1223 B
80 95 12 02H 0.82  
<TS 1224 B
80 95 16 03H 0.87  
<TS 1225 B
80 95 18 04H 0.88  
<TS 1226 B
80 97 14 VS3  
-0.2  
<TS 1227 B
80 115 14 VS3 0.91  
<TS 1228 B
80 115 19 VS4  
-0.87  
<TS 1229 B
80 129 13 03H 0.9  
<TS 1230 B
80 145 29 VS4  
-0.73  
<TS 1231 B
80 145 16 VS5 0.84  
<TS 1232 B
80 145 12 VS5  
-0.89  
<TS 1233 B
80 149 15 01H  
-0.84  
<TS 1234 B
81 22 29 VS3 0.89  
<TS 1235 B
81 22 28 VS4 0.8  
<TS 1236 B
81 24 16 VS3  
-0.85  
<TS 1237 B
81 24 13 VS3 0.89  
<TS 1238 B
81 52 31 VS3 0.84  
<TS 1239 B
81 60 15 03C 0.81  
<TS 1240 B
81 92 13 02C  
-0.88  
<TS 1241 B
81 110 12 03H 0.88  
<TS 1242 B
81 112 16 02H 0.9  
<TS 1243 B
81 114 14 03H 0.81  
<TS 1244 B
81 124 12 03C  
-0.86  
<TS 1245 B
81 126 20 07C 0.77  
<TS 1246 B
81 148 15 VS4  
-0.86  
<TS 1247 B
81 148 17 VS4 0.9  
<TS 1248 B
81 148 17 04C 0.88  
<TS 123 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1249   B       81       148         10       03C       0.85   <TS 1250   B       82       19         18       03H       0.85   <TS 1251   B       82       19         18       04H       0.84   <TS 1252   B       82       19         13       VS4       0.84   <TS 1253   B       82       21         14       VS5       -0.85   <TS 1254   B       82       41         21       VS3       1.02   <TS 1255   B       82       43         8       VS3       -0.69   <TS 1256   B       82       43         20       VS3       0.18   <TS 1257   B       82       43         22       VS3       0.75   <TS 1258   B       82       43         12       VS4       -0.86   <TS 1259   B       82       43         8       VS4       -0.16   <TS 1260   B       82       43         16       VS4       0.73   <TS 1261   B       82       43         28       VS5       -0.73   <TS 1262   B       82       43         21       VS5       -0.16   <TS 1263   B       82       43         24       VS5       0.16   <TS 1264   B       82       43         16       VS5       0.78   <TS 1265   B       82       53         11       05C       0.95   <TS 1266   B       82       59         15       02C         0.9   <TS 1267   B       82       79         13       04H       0.86   <TS 1268   B       82       91         15       04C       -0.79   <TS 1269   B       82       105         10       02H       0.96   <TS 1270   B       82       111         14       04C       -0.9   <TS 1271   B       82       129         15       DBH       1.78   <TS 1272   B       82       137         16       DBH       1.82   <TS 1273   B       82       143         28       VS3       -0.86   <TS 1274   B       82       143         15       VS4       -0.84   <TS 1275   B       82       145         23       VS3       -0.83   <TS 1276   B       82       145         21       VS3       0.94   <TS 1277   B       82       145         17       VS4       -0.9   <TS 1278   B       82       145         29       VS4       0.88   <TS 1279   B       83       26         8       06H       -1.04   <TS 1280   B       83       28         20       VS6         -1   <TS 1281   B       83       28         16       VS6       0.84   <TS 1282   B       83       52         9       02C       -0.9   <TS 1283   B       83       54         14       04H       0.93   <TS 1284   B       83       64         16       03C       0.94   <TS 1285   B       83       78         13       02C       0.86   <TS 1286   B       83       78         13       01C       0.84   <TS 1287   B       83       106         14       03H         0.9   <TS 124 of 156
Percent No SG Row Column in Depth Location Elevation TS 1249 B
81 148 10 03C 0.85  
<TS 1250 B
82 19 18 03H 0.85  
<TS 1251 B
82 19 18 04H 0.84  
<TS 1252 B
82 19 13 VS4 0.84  
<TS 1253 B
82 21 14 VS5  
-0.85  
<TS 1254 B
82 41 21 VS3 1.02  
<TS 1255 B
82 43 8
VS3  
-0.69  
<TS 1256 B
82 43 20 VS3 0.18  
<TS 1257 B
82 43 22 VS3 0.75  
<TS 1258 B
82 43 12 VS4  
-0.86  
<TS 1259 B
82 43 8
VS4  
-0.16  
<TS 1260 B
82 43 16 VS4 0.73  
<TS 1261 B
82 43 28 VS5  
-0.73  
<TS 1262 B
82 43 21 VS5  
-0.16  
<TS 1263 B
82 43 24 VS5 0.16  
<TS 1264 B
82 43 16 VS5 0.78  
<TS 1265 B
82 53 11 05C 0.95  
<TS 1266 B
82 59 15 02C 0.9  
<TS 1267 B
82 79 13 04H 0.86  
<TS 1268 B
82 91 15 04C  
-0.79  
<TS 1269 B
82 105 10 02H 0.96  
<TS 1270 B
82 111 14 04C  
-0.9  
<TS 1271 B
82 129 15 DBH 1.78  
<TS 1272 B
82 137 16 DBH 1.82  
<TS 1273 B
82 143 28 VS3  
-0.86  
<TS 1274 B
82 143 15 VS4  
-0.84  
<TS 1275 B
82 145 23 VS3  
-0.83  
<TS 1276 B
82 145 21 VS3 0.94  
<TS 1277 B
82 145 17 VS4  
-0.9  
<TS 1278 B
82 145 29 VS4 0.88  
<TS 1279 B
83 26 8
06H  
-1.04  
<TS 1280 B
83 28 20 VS6  
-1  
<TS 1281 B
83 28 16 VS6 0.84  
<TS 1282 B
83 52 9
02C  
-0.9  
<TS 1283 B
83 54 14 04H 0.93  
<TS 1284 B
83 64 16 03C 0.94  
<TS 1285 B
83 78 13 02C 0.86  
<TS 1286 B
83 78 13 01C 0.84  
<TS 1287 B
83 106 14 03H 0.9  
<TS 124 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1288   B       83       108         12       04C       -0.89   <TS 1289   B       83       114         11       02H       0.88   <TS 1290   B       83       130         10       DBC       -1.21   <TS 1291   B       83       130         10       DBH         1.5   <TS 1292   B       83       140         11       VS3       -0.84   <TS 1293   B       83       148         28       VS4       -1.02   <TS 1294   B       84       19         19       07H       -0.99   <TS 1295   B       84       25         7       VS2       -0.75   <TS 1296   B       84       47         11       VS6       0.71   <TS 1297   B       84       49         8       04C       -0.91   <TS 1298   B       84       55         14       02C       0.82   <TS 1299   B       84       73         13       04H       0.94   <TS 1300   B       84       77         13       05C       -0.9   <TS 1301   B       84       79         8       03H       0.94   <TS 1302   B       84       81         10       02C       0.85   <TS 1303   B       84       87         15       03H       0.89   <TS 1304   B       84       87         13       04C       0.92   <TS 1305   B       84       93         15       02C       -0.9   <TS 1306   B       84       103         7       04C       0.44   <TS 1307   B       84       107         13       02H       -0.83   <TS 1308   B       84       111         12       04H       -0.92   <TS 1309   B       84       111         8       05H       0.96   <TS 1310   B       84       125         12       04H       -0.92   <TS 1311   B       84       125         9       VS2       -0.92   <TS 1312   B       84       145         14       03C       -0.86   <TS 1313   B       84       147         11       07H       0.77   <TS 1314   B       84       147         26       DBH       1.77   <TS 1315   B       85       20         14       VS4       -0.84   <TS 1316   B       85       20         17       VS4       0.91   <TS 1317   B       85       36         15       04H       -0.88   <TS 1318   B       85       36         21       VS6       -0.91   <TS 1319   B       85       78         14       05H       0.93   <TS 1320   B       85       80         10       01H       0.87   <TS 1321   B       85       82         12       VS6       -0.83   <TS 1322   B       85       110         16       04C       0.87   <TS 1323   B       85       112         14       03H       0.49   <TS 1324   B       85       140         14       040       0.86   <TS 1325   B       85       142         20       03C       -0.85   <TS 1326   B       85       144         17       03C       -0.88   <TS 125 of 156
Percent No SG Row Column in Depth Location Elevation TS 1288 B
83 108 12 04C  
-0.89  
<TS 1289 B
83 114 11 02H 0.88  
<TS 1290 B
83 130 10 DBC  
-1.21  
<TS 1291 B
83 130 10 DBH 1.5  
<TS 1292 B
83 140 11 VS3  
-0.84  
<TS 1293 B
83 148 28 VS4  
-1.02  
<TS 1294 B
84 19 19 07H  
-0.99  
<TS 1295 B
84 25 7
VS2  
-0.75  
<TS 1296 B
84 47 11 VS6 0.71  
<TS 1297 B
84 49 8
04C  
-0.91  
<TS 1298 B
84 55 14 02C 0.82  
<TS 1299 B
84 73 13 04H 0.94  
<TS 1300 B
84 77 13 05C  
-0.9  
<TS 1301 B
84 79 8
03H 0.94  
<TS 1302 B
84 81 10 02C 0.85  
<TS 1303 B
84 87 15 03H 0.89  
<TS 1304 B
84 87 13 04C 0.92  
<TS 1305 B
84 93 15 02C  
-0.9  
<TS 1306 B
84 103 7
04C 0.44  
<TS 1307 B
84 107 13 02H  
-0.83  
<TS 1308 B
84 111 12 04H  
-0.92  
<TS 1309 B
84 111 8
05H 0.96  
<TS 1310 B
84 125 12 04H  
-0.92  
<TS 1311 B
84 125 9
VS2  
-0.92  
<TS 1312 B
84 145 14 03C  
-0.86  
<TS 1313 B
84 147 11 07H 0.77  
<TS 1314 B
84 147 26 DBH 1.77  
<TS 1315 B
85 20 14 VS4  
-0.84  
<TS 1316 B
85 20 17 VS4 0.91  
<TS 1317 B
85 36 15 04H  
-0.88  
<TS 1318 B
85 36 21 VS6  
-0.91  
<TS 1319 B
85 78 14 05H 0.93  
<TS 1320 B
85 80 10 01H 0.87  
<TS 1321 B
85 82 12 VS6  
-0.83  
<TS 1322 B
85 110 16 04C 0.87  
<TS 1323 B
85 112 14 03H 0.49  
<TS 1324 B
85 140 14 040 0.86  
<TS 1325 B
85 142 20 03C  
-0.85  
<TS 1326 B
85 144 17 03C  
-0.88  
<TS 125 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1327   B       85       146         12       04C       -0.92   <TS 1328   B       85       146         16       03C       -0.9   <TS 1329   B       86       21         16       01C       -0.88   <TS 1330   B       86       31         12       06H       0.84   <TS 1331   B       86       33         14       06H       0.89   <TS 1332   B       86       51         19       03C         0.9   <TS 1333   B       86       61         8       02C       0.13   <TS 1334   B       86       67         11       03C       -0.87   <TS 1335   B       86       79         12       04H         0.9   <TS 1336   B       86       89         15       03C       0.81   <TS 1337   B       86       91         7       03C       -0.88   <TS 1338   B       86       111         13       04C       -0.87   <TS 1339   B       86       145         16       03C         0.9   <TS 1340   B       87       20         16       VS4       -0.86   <TS 1341   B       87       30         13       04H       0.94   <TS 1342   B       87       38         15       VS6       -0.69   <TS 1343   B       87       62         12       04C       -0.9   <TS 1344   B       87       74         10       07H       0.94   <TS 1345   B       87       82         15       03H       0.89   <TS 1346   B       87       84         13       02C         0.9   <TS 1347   B       87       88         20       04C       -0.86   <TS 1348   B       87       106         11       03H       -0.79   <TS 1349   B       87       116         15       04C       0.84   <TS 1350   B       87       146         20       VS4       -0.93   <TS 1351   B       87       146         16       VS4       0.95   <TS 1352   B       87       146         32       03C         0.8   <TS 1353   B       88       27         11       04H       0.81   <TS 1354   B       88       27         21       DBH       1.99   <TS 1355   B       88       29         14       06H       0.86   <TS 1356   B       88       67         12       VS2       -0.86   <TS 1357   B       88       67         15       VS2       0.83   <TS 1358   B       88       79         13       07C       0.88   <TS 1359   B       88       87         15       05C       0.86   <TS 1360   B       88       95         21       03C       0.86   <TS 1361   B       88       107         14       04C       -0.92   <TS 1362   B       88       117         12       04C       -0.9   <TS 1363   B       88       133         10       04H       -0.04   <TS 1364   B       89       38           9       05H       -0.86   <TS 1365   B       89       38         12       VS2       -0.97   <TS 126 of 156
Percent No SG Row Column in Depth Location Elevation TS 1327 B
85 146 12 04C  
-0.92  
<TS 1328 B
85 146 16 03C  
-0.9  
<TS 1329 B
86 21 16 01C  
-0.88  
<TS 1330 B
86 31 12 06H 0.84  
<TS 1331 B
86 33 14 06H 0.89  
<TS 1332 B
86 51 19 03C 0.9  
<TS 1333 B
86 61 8
02C 0.13  
<TS 1334 B
86 67 11 03C  
-0.87  
<TS 1335 B
86 79 12 04H 0.9  
<TS 1336 B
86 89 15 03C 0.81  
<TS 1337 B
86 91 7
03C  
-0.88  
<TS 1338 B
86 111 13 04C  
-0.87  
<TS 1339 B
86 145 16 03C 0.9  
<TS 1340 B
87 20 16 VS4  
-0.86  
<TS 1341 B
87 30 13 04H 0.94  
<TS 1342 B
87 38 15 VS6  
-0.69  
<TS 1343 B
87 62 12 04C  
-0.9  
<TS 1344 B
87 74 10 07H 0.94  
<TS 1345 B
87 82 15 03H 0.89  
<TS 1346 B
87 84 13 02C 0.9  
<TS 1347 B
87 88 20 04C  
-0.86  
<TS 1348 B
87 106 11 03H  
-0.79  
<TS 1349 B
87 116 15 04C 0.84  
<TS 1350 B
87 146 20 VS4  
-0.93  
<TS 1351 B
87 146 16 VS4 0.95  
<TS 1352 B
87 146 32 03C 0.8  
<TS 1353 B
88 27 11 04H 0.81  
<TS 1354 B
88 27 21 DBH 1.99  
<TS 1355 B
88 29 14 06H 0.86  
<TS 1356 B
88 67 12 VS2  
-0.86  
<TS 1357 B
88 67 15 VS2 0.83  
<TS 1358 B
88 79 13 07C 0.88  
<TS 1359 B
88 87 15 05C 0.86  
<TS 1360 B
88 95 21 03C 0.86  
<TS 1361 B
88 107 14 04C  
-0.92  
<TS 1362 B
88 117 12 04C  
-0.9  
<TS 1363 B
88 133 10 04H  
-0.04  
<TS 1364 B
89 38 9
05H  
-0.86  
<TS 1365 B
89 38 12 VS2  
-0.97  
<TS 126 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1366   B       89       42         13       VS6       0.91   <TS 1367   B       89       44         15       VS2       -0.86   <TS 1368   B       89       44         15       VS6       -0.86   <TS 1369   B       89       54         12       06H       -0.89   <TS 1370   B       89       56         12       02C       0.92   <TS 1371   B       89       56         9       02C       -0.18   <TS 1372   B       89       58         8       DBC       1.75   <TS 1373   B       89       60         16       04C       -0.92   <TS 1374   B       89       78         14       07C       0.85   <TS 1375   B       89       82         14       07C       0.88   <TS 1376   B       89       84         16       03H       0.86   <TS 1377   B       89       92         20       04C       0.46   <TS 1378   B       89       100         12       03H       0.89   <TS 1379   B       89       104         13       05C       -0.9   <TS 1380   B       89       104         15       04C       -0.86   <TS 1381   B       89       104         13       04H       0.89   <TS 1382   B       89       134         16       04H       0.94   <TS 1383   B       89       140         11       DBC       1.46   <TS 1384   B       89       144         13       01H       -0.8   <TS 1385   B       90       23         14       VS4       -0.98   <TS 1386   B       90       31         12       VS2       -0.93   <TS 1387   B       90       55         16       VS2       0.97   <TS 1388   B       90       55         11       02C       -0.88   <TS 1389   B       90       57         14       02C       0.88   <TS 1390   B       90       65         16       03C       0.83   <TS 1391   B       90       69         12       07H       -1.01   <TS 1392   B       90       87         11       02C       -0.88   <TS 1393   B       90       87         12       02C       -0.2   <TS 1394   B       90       89         11       03H       0.91   <TS 1395   B       90       95         18       04C       0.94   <TS 1396   B       90       97         14       04C       0.92   <TS 1397   B       90       115         13       03H       -0.87   <TS 1398   B       90       127         18       04H       -0.87   <TS 1399   B       90       131         12       07H       0.92   <TS 1400   B       91       22         28       VS6       0.97   <TS 1401   B       91       26         13       02C       0.91   <TS 1402   B       91       32         16       02C       -0.91   <TS 1403   B       91       38         14       03H       -0.9   <TS 1404   B       91       54         12       02C       0.91   <TS 127 of 156
Percent No SG Row Column in Depth Location Elevation TS 1366 B
89 42 13 VS6 0.91  
<TS 1367 B
89 44 15 VS2  
-0.86  
<TS 1368 B
89 44 15 VS6  
-0.86  
<TS 1369 B
89 54 12 06H  
-0.89  
<TS 1370 B
89 56 12 02C 0.92  
<TS 1371 B
89 56 9
02C  
-0.18  
<TS 1372 B
89 58 8
DBC 1.75  
<TS 1373 B
89 60 16 04C  
-0.92  
<TS 1374 B
89 78 14 07C 0.85  
<TS 1375 B
89 82 14 07C 0.88  
<TS 1376 B
89 84 16 03H 0.86  
<TS 1377 B
89 92 20 04C 0.46  
<TS 1378 B
89 100 12 03H 0.89  
<TS 1379 B
89 104 13 05C  
-0.9  
<TS 1380 B
89 104 15 04C  
-0.86  
<TS 1381 B
89 104 13 04H 0.89  
<TS 1382 B
89 134 16 04H 0.94  
<TS 1383 B
89 140 11 DBC 1.46  
<TS 1384 B
89 144 13 01H  
-0.8  
<TS 1385 B
90 23 14 VS4  
-0.98  
<TS 1386 B
90 31 12 VS2  
-0.93  
<TS 1387 B
90 55 16 VS2 0.97  
<TS 1388 B
90 55 11 02C  
-0.88  
<TS 1389 B
90 57 14 02C 0.88  
<TS 1390 B
90 65 16 03C 0.83  
<TS 1391 B
90 69 12 07H  
-1.01  
<TS 1392 B
90 87 11 02C  
-0.88  
<TS 1393 B
90 87 12 02C  
-0.2  
<TS 1394 B
90 89 11 03H 0.91  
<TS 1395 B
90 95 18 04C 0.94  
<TS 1396 B
90 97 14 04C 0.92  
<TS 1397 B
90 115 13 03H  
-0.87  
<TS 1398 B
90 127 18 04H  
-0.87  
<TS 1399 B
90 131 12 07H 0.92  
<TS 1400 B
91 22 28 VS6 0.97  
<TS 1401 B
91 26 13 02C 0.91  
<TS 1402 B
91 32 16 02C  
-0.91  
<TS 1403 B
91 38 14 03H  
-0.9  
<TS 1404 B
91 54 12 02C 0.91  
<TS 127 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1405   B       91       58         16       03C       0.85   <TS 1406   B       91       60         11       03C       -0.92   <TS 1407   B       91       60         9       04C       -0.9   <TS 1408   B       91       64         20       03C       -0.9   <TS 1409   B       91       70         10       04H       0.94   <TS 1410   B       91       70         10       06C       -0.92   <TS 1411   B       91       86         15       VS6       0.92   <TS 1412   B       91       88         16       04H       -0.9   <TS 1413   B       91       88         10       03C       0.86   <TS 1414   B       91       94         13       06C       -0.88   <TS 1415   B       91       98         11       03C       0.86   <TS 1416   B       91       124         17       04C         0.9   <TS 1417   B       91       140         12       04H       0.83   <TS 1418   B       91       144         15       VS4       -0.9   <TS 1419   B       91       144         16       VS4       0.83   <TS 1420   B       92       23         9       VS4       -0.9   <TS 1421   B       92       23         11       VS4       0.73   <TS 1422   B       92       23         12       02C       0.79   <TS 1423   B       92       23         8       02C       -0.61   <TS 1424   B       92       23         9       03H       -0.86   <TS 1425   B       92       31         16       VS2         -1   <TS 1426   B       92       31         12       VS2       0.98   <TS 1427   B       92       35         9       05H       0.85   <TS 1428   B       92       49         13       05H       0.96   <TS 1429   B       92       55         14       03C       0.83   <TS 1430   B       92       57         14       04H       0.79   <TS 1431   B       92       61         11       03C       -0.92   <TS 1432   B       92       69         15       04C       0.92   <TS 1433   B       92       73         8       VS2       0.86   <TS 1434   B       92       75           7       05H       0.93   <TS 1435   B       92       81           7       DBH       -1.8   <TS 1436   B       92       83         19       05H       0.93   <TS 1437   B       92       85         10       03H       -0.89   <TS 1438   B       92       89         12       04H       0.85   <TS 1439   B       92       97         11       04C       0.09   <TS 1440   B       92       97         17       04C       0.88   <TS 1441   B       92       99         11       04C       -0.83   <TS 1442   B       92       105         13       04C       -0.86   <TS 1443   B       92       111         10       07C       0.83   <TS 128 of 156
Percent No SG Row Column in Depth Location Elevation TS 1405 B
91 58 16 03C 0.85  
<TS 1406 B
91 60 11 03C  
-0.92  
<TS 1407 B
91 60 9
04C  
-0.9  
<TS 1408 B
91 64 20 03C  
-0.9  
<TS 1409 B
91 70 10 04H 0.94  
<TS 1410 B
91 70 10 06C  
-0.92  
<TS 1411 B
91 86 15 VS6 0.92  
<TS 1412 B
91 88 16 04H  
-0.9  
<TS 1413 B
91 88 10 03C 0.86  
<TS 1414 B
91 94 13 06C  
-0.88  
<TS 1415 B
91 98 11 03C 0.86  
<TS 1416 B
91 124 17 04C 0.9  
<TS 1417 B
91 140 12 04H 0.83  
<TS 1418 B
91 144 15 VS4  
-0.9  
<TS 1419 B
91 144 16 VS4 0.83  
<TS 1420 B
92 23 9
VS4  
-0.9  
<TS 1421 B
92 23 11 VS4 0.73  
<TS 1422 B
92 23 12 02C 0.79  
<TS 1423 B
92 23 8
02C  
-0.61  
<TS 1424 B
92 23 9
03H  
-0.86  
<TS 1425 B
92 31 16 VS2  
-1  
<TS 1426 B
92 31 12 VS2 0.98  
<TS 1427 B
92 35 9
05H 0.85  
<TS 1428 B
92 49 13 05H 0.96  
<TS 1429 B
92 55 14 03C 0.83  
<TS 1430 B
92 57 14 04H 0.79  
<TS 1431 B
92 61 11 03C  
-0.92  
<TS 1432 B
92 69 15 04C 0.92  
<TS 1433 B
92 73 8
VS2 0.86  
<TS 1434 B
92 75 7
05H 0.93  
<TS 1435 B
92 81 7
DBH  
-1.8  
<TS 1436 B
92 83 19 05H 0.93  
<TS 1437 B
92 85 10 03H  
-0.89  
<TS 1438 B
92 89 12 04H 0.85  
<TS 1439 B
92 97 11 04C 0.09  
<TS 1440 B
92 97 17 04C 0.88  
<TS 1441 B
92 99 11 04C  
-0.83  
<TS 1442 B
92 105 13 04C  
-0.86  
<TS 1443 B
92 111 10 07C 0.83  
<TS 128 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1444   B       92       125         13       VS2       0.85   <TS 1445   B       93       30         18       VS4       -0.91   <TS 1446   B       93       42         13       VS2       0.75   <TS 1447   B       93       56         12       02C         0.9   <TS 1448   B       93       62         14       03C       0.94   <TS 1449   B       93       62         12       02C         0.9   <TS 1450   B       93       80         12       03C       -0.72   <TS 1451   B       93       98         10       04C       -0.9   <TS 1452   B       93       104         14       04H       -0.82   <TS 1453   B       93       112         11       03H       0.85   <TS 1454   B       93       112         16       VS6       0.68   <TS 1455   B       93       130         10       04H         0.9   <TS 1456   B       93       132         15       04H         0.9   <TS 1457   B       93       136         11       03C       0.86   <TS 1458   B       94       37         16       VS2       -0.86   <TS 1459   B       94       53         13       05H       -0.84   <TS 1460   B       94       57         13       03C       0.79   <TS 1461   B       94       57         16       02C       0.75   <TS 1462   B       94       81         12       02C       0.86   <TS 1463   B       94       93         13       03C       -0.86   <TS 1464   B       94       93         13       04C       -0.11   <TS 1465   B       94       93         10       04C       -0.88   <TS 1466   B       94       101         16       06H       -0.93   <TS 1467   B       94       111         18       VS6       -0.77   <TS 1468   B       94       115         11       04C       -0.94   <TS 1469   B       94       129         17       04H       0.88   <TS 1470   B       94       131         14       03C       -0.86   <TS 1471   B       94       137         13       VS4       -0.84   <TS 1472   B       95       24         19       VS4       -0.78   <TS 1473   B       95       24         12       VS4       -0.13   <TS 1474   B       95       24         14       VS4       0.72   <TS 1475   B       95       36         16       VS4       -0.88   <TS 1476   B       95       36         17       VS4       0.91   <TS 1477   B       95       42         19       DBC       -0.33   <TS 1478   B       95       70         12       04H       0.85   <TS 1479   B       95       70         17       VS6       -0.97   <TS 1480   B       95       84         11       07C       0.07   <TS 1481   B       95       84         17       07C       0.9   <TS 1482   B       95       88         12       02C       0.83   <TS 129 of 156
Percent No SG Row Column in Depth Location Elevation TS 1444 B
92 125 13 VS2 0.85  
<TS 1445 B
93 30 18 VS4  
-0.91  
<TS 1446 B
93 42 13 VS2 0.75  
<TS 1447 B
93 56 12 02C 0.9  
<TS 1448 B
93 62 14 03C 0.94  
<TS 1449 B
93 62 12 02C 0.9  
<TS 1450 B
93 80 12 03C  
-0.72  
<TS 1451 B
93 98 10 04C  
-0.9  
<TS 1452 B
93 104 14 04H  
-0.82  
<TS 1453 B
93 112 11 03H 0.85  
<TS 1454 B
93 112 16 VS6 0.68  
<TS 1455 B
93 130 10 04H 0.9  
<TS 1456 B
93 132 15 04H 0.9  
<TS 1457 B
93 136 11 03C 0.86  
<TS 1458 B
94 37 16 VS2  
-0.86  
<TS 1459 B
94 53 13 05H  
-0.84  
<TS 1460 B
94 57 13 03C 0.79  
<TS 1461 B
94 57 16 02C 0.75  
<TS 1462 B
94 81 12 02C 0.86  
<TS 1463 B
94 93 13 03C  
-0.86  
<TS 1464 B
94 93 13 04C  
-0.11  
<TS 1465 B
94 93 10 04C  
-0.88  
<TS 1466 B
94 101 16 06H  
-0.93  
<TS 1467 B
94 111 18 VS6  
-0.77  
<TS 1468 B
94 115 11 04C  
-0.94  
<TS 1469 B
94 129 17 04H 0.88  
<TS 1470 B
94 131 14 03C  
-0.86  
<TS 1471 B
94 137 13 VS4  
-0.84  
<TS 1472 B
95 24 19 VS4  
-0.78  
<TS 1473 B
95 24 12 VS4  
-0.13  
<TS 1474 B
95 24 14 VS4 0.72  
<TS 1475 B
95 36 16 VS4  
-0.88  
<TS 1476 B
95 36 17 VS4 0.91  
<TS 1477 B
95 42 19 DBC  
-0.33  
<TS 1478 B
95 70 12 04H 0.85  
<TS 1479 B
95 70 17 VS6  
-0.97  
<TS 1480 B
95 84 11 07C 0.07  
<TS 1481 B
95 84 17 07C 0.9  
<TS 1482 B
95 88 12 02C 0.83  
<TS 129 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 1483   B       95       102       17       05H       0.82   <TS 1484   B       95       104       15       03H       -0.87   <TS 1485   B       95       104         9       03C       0.13   <TS 1486   B       95       106       19       04C       -0.87   <TS 1487   B       95       116       20       VS2       -1.08   <TS 1488   B       95       126       11       04H       0.91   <TS 1489   B       95       134       18       VS2         0.9   <TS 1490   B       95       134       12       VS2       0.12   <TS 1491   B       95       136       19       03C       -0.37   <TS 1492   B       95       138       39       VS4       0.92   <TS 1493   B       95       138       14       03C       0.79   <TS 1494   B       95       138       19       VS4       -0.79   <TS 1495   B       95       138       16       VS2       0.13   <TS 1496   B       95       140       17       03C       -0.94   <TS 1497   B       95       142       22       VS4       0.75   <TS 1498   B       95       142       14       VS6       -0.79   <TS 1499   B       96       25         11       02H       -1.02   <TS 1500   B       96       29         17       VS4         0.8   <TS 1501   B       96       53         13       05H       0.83   <TS 1502   B       96       57         13       02H       0.84   <TS 1503   B       96       57         16       VS4       1.14   <TS 1504   B       96       61         13       02H       0.87   <TS 1505   B       96       65         13       04C       0.81   <TS 1506   B       96       65         13       02C       0.77   <TS 1507   B       96       71         9       04H       -0.09   <TS 1508   B       96       71         16       04H       -0.94   <TS 1509   B       96       79         9       VS2         0.7   <TS 1510   B       96       95         21       VS2       -0.97   <TS 1511   B       96       95         13       VS2       0.11   <TS 1512   B       96       95         21       VS2       0.75   <TS 1513   B       96       103         15       04C         0.9   <TS 1514   B       96       117         19       VS2       0.85   <TS 1515   B       96       133         9       03H       -0.96   <TS 1516   B       96       133         8       04H       -0.06   <TS 1517   B       96       137         15       VS4       -0.26   <TS 1518   B       96       137         23       VS4         0.9   <TS 1519   B       96       137         18       04C       -0.15   <TS 1520   B       96       137         13       03C       0.89   <TS 1521   B       96       139         19       03C       -0.94   <TS 130 of 156
Percent No SG Row Column in Depth Location Elevation TS 1483 B
95 102 17 05H 0.82  
<TS 1484 B
95 104 15 03H  
-0.87  
<TS 1485 B
95 104 9
03C 0.13  
<TS 1486 B
95 106 19 04C  
-0.87  
<TS 1487 B
95 116 20 VS2  
-1.08  
<TS 1488 B
95 126 11 04H 0.91  
<TS 1489 B
95 134 18 VS2 0.9  
<TS 1490 B
95 134 12 VS2 0.12  
<TS 1491 B
95 136 19 03C  
-0.37  
<TS 1492 B
95 138 39 VS4 0.92  
<TS 1493 B
95 138 14 03C 0.79  
<TS 1494 B
95 138 19 VS4  
-0.79  
<TS 1495 B
95 138 16 VS2 0.13  
<TS 1496 B
95 140 17 03C  
-0.94  
<TS 1497 B
95 142 22 VS4 0.75  
<TS 1498 B
95 142 14 VS6  
-0.79  
<TS 1499 B
96 25 11 02H  
-1.02  
<TS 1500 B
96 29 17 VS4 0.8  
<TS 1501 B
96 53 13 05H 0.83  
<TS 1502 B
96 57 13 02H 0.84  
<TS 1503 B
96 57 16 VS4 1.14  
<TS 1504 B
96 61 13 02H 0.87  
<TS 1505 B
96 65 13 04C 0.81  
<TS 1506 B
96 65 13 02C 0.77  
<TS 1507 B
96 71 9
04H  
-0.09  
<TS 1508 B
96 71 16 04H  
-0.94  
<TS 1509 B
96 79 9
VS2 0.7  
<TS 1510 B
96 95 21 VS2  
-0.97  
<TS 1511 B
96 95 13 VS2 0.11  
<TS 1512 B
96 95 21 VS2 0.75  
<TS 1513 B
96 103 15 04C 0.9  
<TS 1514 B
96 117 19 VS2 0.85  
<TS 1515 B
96 133 9
03H  
-0.96  
<TS 1516 B
96 133 8
04H  
-0.06  
<TS 1517 B
96 137 15 VS4  
-0.26  
<TS 1518 B
96 137 23 VS4 0.9  
<TS 1519 B
96 137 18 04C  
-0.15  
<TS 1520 B
96 137 13 03C 0.89  
<TS 1521 B
96 139 19 03C  
-0.94  
<TS 130 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1522   B       96       141         17       VS2       0.79   <TS 1523   B       96       141         22       VS4         1   <TS 1524   B       97       26         17       VS4       -0.72   <TS 1525   B       97       28         22       03C         0.9   <TS 1526   B       97       34         12       VS6       -0.84   <TS 1527   B       97       38         10       05H       0.87   <TS 1528   B       97       40         15       VS2       -0.77   <TS 1529   B       97       42         13       VS2       -0.93   <TS 1530   B       97       46         11       VS4       0.89   <TS 1531   B       97       54         11       07C       0.86   <TS 1532   B       97       60         17       VS2       0.98   <TS 1533   B       97       60         16       06C         0.9   <TS 1534   B       97       72         11       04H       0.94   <TS 1535   B       97       84         16       07C       -0.88   <TS 1536   B       97       84         10       07C       -0.11   <TS 1537   B       97       86         11       03C       0.83   <TS 1538   B       97       100         13       VS2       0.73   <TS 1539   B       97       130         14       04H       0.85   <TS 1540   B       97       140         13       03H       0.74   <TS 1541   B       97       140         9       DBH       1.54   <TS 1542   B       97       140         14       VS4       -0.86   <TS 1543   B       98       27         15       VS4       -0.91   <TS 1544   B       98       27         21       04C       -0.96   <TS 1545   B       98       39         16       VS4         0.8   <TS 1546   B       98       41         12       VS2       -0.93   <TS 1547   B       98       41         21       VS2       0.82   <TS 1548   B       98       41         25       VS4       0.77   <TS 1549   B       98       49         19       VS2       -0.57   <TS 1550   B       98       51         10       04H       0.89   <TS 1551   B       98       55         29       VS2       -0.9   <TS 1552   B       98       59         16       VS2       -0.94   <TS 1553   B       98       59         14       VS2       0.94   <TS 1554   B       98       71         16       VS2       0.92   <TS 1555   B       98       71         8       VS2       -0.86   <TS 1556   B       98       79         13       03C       0.87   <TS 1557   B       98       79         10       03C       0.09   <TS 1558   B       98       81         15       VS2       0.86   <TS 1559   B       98       93         18       03C       0.88   <TS 1560   B       98       117         15       VS2       0.88   <TS 131 of 156
Percent No SG Row Column in Depth Location Elevation TS 1522 B
96 141 17 VS2 0.79  
<TS 1523 B
96 141 22 VS4 1  
<TS 1524 B
97 26 17 VS4  
-0.72  
<TS 1525 B
97 28 22 03C 0.9  
<TS 1526 B
97 34 12 VS6  
-0.84  
<TS 1527 B
97 38 10 05H 0.87  
<TS 1528 B
97 40 15 VS2  
-0.77  
<TS 1529 B
97 42 13 VS2  
-0.93  
<TS 1530 B
97 46 11 VS4 0.89  
<TS 1531 B
97 54 11 07C 0.86  
<TS 1532 B
97 60 17 VS2 0.98  
<TS 1533 B
97 60 16 06C 0.9  
<TS 1534 B
97 72 11 04H 0.94  
<TS 1535 B
97 84 16 07C  
-0.88  
<TS 1536 B
97 84 10 07C  
-0.11  
<TS 1537 B
97 86 11 03C 0.83  
<TS 1538 B
97 100 13 VS2 0.73  
<TS 1539 B
97 130 14 04H 0.85  
<TS 1540 B
97 140 13 03H 0.74  
<TS 1541 B
97 140 9
DBH 1.54  
<TS 1542 B
97 140 14 VS4  
-0.86  
<TS 1543 B
98 27 15 VS4  
-0.91  
<TS 1544 B
98 27 21 04C  
-0.96  
<TS 1545 B
98 39 16 VS4 0.8  
<TS 1546 B
98 41 12 VS2  
-0.93  
<TS 1547 B
98 41 21 VS2 0.82  
<TS 1548 B
98 41 25 VS4 0.77  
<TS 1549 B
98 49 19 VS2  
-0.57  
<TS 1550 B
98 51 10 04H 0.89  
<TS 1551 B
98 55 29 VS2  
-0.9  
<TS 1552 B
98 59 16 VS2  
-0.94  
<TS 1553 B
98 59 14 VS2 0.94  
<TS 1554 B
98 71 16 VS2 0.92  
<TS 1555 B
98 71 8
VS2  
-0.86  
<TS 1556 B
98 79 13 03C 0.87  
<TS 1557 B
98 79 10 03C 0.09  
<TS 1558 B
98 81 15 VS2 0.86  
<TS 1559 B
98 93 18 03C 0.88  
<TS 1560 B
98 117 15 VS2 0.88  
<TS 131 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1561   B       98       133       17       02C       0.79   <TS 1562   B       98       135       22       VS2         0   <TS 1563   B       98       135       24       VS4       -0.72   <TS 1564   B       98       135       28       VS4       0.94   <TS 1565   B       98       139       17       VS4       0.85   <TS 1566   B       98       139       21       VS4       0.22   <TS 1567   B       98       139       14       03C       -0.91   <TS 1568   B       98       139       13       04H       -0.15   <TS 1569   B       99       32         14       02C       0.84   <TS 1570   B       99       40         11       02H       0.81   <TS 1571   B       99       44         9       05H       0.92   <TS 1572   B       99       50         20       05H       0.54   <TS 1573   B       99       52       12       03C       0.86   <TS 1574   B       99       82         13       VS2       -0.83   <TS 1575   B       99       86         11       VS6         0.2   <TS 1576   B       99       132       26       VS2       -0.72   <TS 1577   B       99       132       13       VS2       -0.22   <TS 1578   B       99       132       31       VS2       0.72   <TS 1579   B       99       132       23       VS4         0.9   <TS 1580   B       99       136       18       04C       0.79   <TS 1581   B       99       138         8       DBH       1.98   <TS 1582   B       100     27         22       VS4       -0.97   <TS 1583   B       100     27         12       VS4       0.86   <TS 1584   B       100     29         15       VS6       -0.88   <TS 1585   B       100     29         17       03C       0.82   <TS 1586   B       100     89         12       VS4       0.79   <TS 1587   B       100     103       13       VS2       0.81   <TS 1588   B       100     109       22       VS2       -0.72   <TS 1589   B       100     115       12       03C       0.87   <TS 1590   B       100     121       13       06C       0.92   <TS 1591   B       100     125       31       VS2       -0.7   <TS 1592   B       100     125       35       VS2       -0.07   <TS 1593   B       100     125       17       VS2         0.7   <TS 1594   B       100     125       14       VS4       -0.7   <TS 1595   B       100     125       25       VS4         0.9   <TS 1596   B       100     125       15       VS6       -0.11   <TS 1597   B       100     125       19       VS6       0.97   <TS 1598   B       100     125       13       DBC       -1.8   <TS 1599   B       100     133       16       VS4       -0.72   <TS 132 of 156
Percent No SG Row Column in Depth Location Elevation TS 1561 B
98 133 17 02C 0.79  
<TS 1562 B
98 135 22 VS2 0  
<TS 1563 B
98 135 24 VS4  
-0.72  
<TS 1564 B
98 135 28 VS4 0.94  
<TS 1565 B
98 139 17 VS4 0.85  
<TS 1566 B
98 139 21 VS4 0.22  
<TS 1567 B
98 139 14 03C  
-0.91  
<TS 1568 B
98 139 13 04H  
-0.15  
<TS 1569 B
99 32 14 02C 0.84  
<TS 1570 B
99 40 11 02H 0.81  
<TS 1571 B
99 44 9
05H 0.92  
<TS 1572 B
99 50 20 05H 0.54  
<TS 1573 B
99 52 12 03C 0.86  
<TS 1574 B
99 82 13 VS2  
-0.83  
<TS 1575 B
99 86 11 VS6 0.2  
<TS 1576 B
99 132 26 VS2  
-0.72  
<TS 1577 B
99 132 13 VS2  
-0.22  
<TS 1578 B
99 132 31 VS2 0.72  
<TS 1579 B
99 132 23 VS4 0.9  
<TS 1580 B
99 136 18 04C 0.79  
<TS 1581 B
99 138 8
DBH 1.98  
<TS 1582 B
100 27 22 VS4  
-0.97  
<TS 1583 B
100 27 12 VS4 0.86  
<TS 1584 B
100 29 15 VS6  
-0.88  
<TS 1585 B
100 29 17 03C 0.82  
<TS 1586 B
100 89 12 VS4 0.79  
<TS 1587 B
100 103 13 VS2 0.81  
<TS 1588 B
100 109 22 VS2  
-0.72  
<TS 1589 B
100 115 12 03C 0.87  
<TS 1590 B
100 121 13 06C 0.92  
<TS 1591 B
100 125 31 VS2  
-0.7  
<TS 1592 B
100 125 35 VS2  
-0.07  
<TS 1593 B
100 125 17 VS2 0.7  
<TS 1594 B
100 125 14 VS4  
-0.7  
<TS 1595 B
100 125 25 VS4 0.9  
<TS 1596 B
100 125 15 VS6  
-0.11  
<TS 1597 B
100 125 19 VS6 0.97  
<TS 1598 B
100 125 13 DBC  
-1.8  
<TS 1599 B
100 133 16 VS4  
-0.72  
<TS 132 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1600   B       100     135         13       03H       0.94   <TS 1601   B       101       28         17       VS4       -0.82   <TS 1602   B       101       28         13       VS4       -0.09   <TS 1603   B       101       30         20       04C       0.86   <TS 1604   B       101       30         13       03C       0.87   <TS 1605   B       101       30         20       03C       -0.93   <TS 1606   B       101       30         11       02C       0.84   <TS 1607   B       101       30         12       03H       -0.89   <TS 1608   B       101       32         23       VS2       0.71   <TS 1609   B       101       32         11       VS4       0.93   <TS 1610   B       101       36         12       05H         0.9   <TS 1611   B       101       36         11       03C       0.89   <TS 1612   B       101       38         8       DBC       1.43   <TS 1613   B       101       54         18       02C         0.9   <TS 1614   B       101       66         13       VS4       1.19   <TS 1615   B       101       78         7       05H       0.88   <TS 1616   B       101     98         15       04C       -1.01   <TS 1617   B       101     104         21       DBH       1.36   <TS 1618   B       101     130         12       04C       0.46   <TS 1619   B       101     136         16       03H       0.92   <TS 1620   B       101     138         14       03H       0.86   <TS 1621   B       101     138         11       VS4       -0.88   <TS 1622   B       102     29         13       04C       0.84   <TS 1623   B       102       31         18       02C       -0.89   <TS 1624   B       102       33         22       03C       -0.89   <TS 1625   B       102       35         22       03C       0.89   <TS 1626   B       102       37         11       02C       -0.88   <TS 1627   B       102     41         18       06H       0.86   <TS 1628   B       102     41           9       06H       -0.86   <TS 1629   B       102     49         14       VS2       0.82   <TS 1630   B       102       51         18       07C       0.88   <TS 1631   B       102     85         28       VS6       -0.83   <TS 1632   B       102     93         11       04C       -0.15   <TS 1633   B       102     93         10       04C       -0.92   <TS 1634   B       102     99         17       07C         0.9   <TS 1635   B       102     99         11       07C       0.07   <TS 1636   B       102     113         14       DBH       1.67   <TS 1637   B       102     123         11       04H       0.92   <TS 1638   B       102     127         13       VS4       0.81   <TS 133 of 156
Percent No SG Row Column in Depth Location Elevation TS 1600 B
100 135 13 03H 0.94  
<TS 1601 B
101 28 17 VS4  
-0.82  
<TS 1602 B
101 28 13 VS4  
-0.09  
<TS 1603 B
101 30 20 04C 0.86  
<TS 1604 B
101 30 13 03C 0.87  
<TS 1605 B
101 30 20 03C  
-0.93  
<TS 1606 B
101 30 11 02C 0.84  
<TS 1607 B
101 30 12 03H  
-0.89  
<TS 1608 B
101 32 23 VS2 0.71  
<TS 1609 B
101 32 11 VS4 0.93  
<TS 1610 B
101 36 12 05H 0.9  
<TS 1611 B
101 36 11 03C 0.89  
<TS 1612 B
101 38 8
DBC 1.43  
<TS 1613 B
101 54 18 02C 0.9  
<TS 1614 B
101 66 13 VS4 1.19  
<TS 1615 B
101 78 7
05H 0.88  
<TS 1616 B
101 98 15 04C  
-1.01  
<TS 1617 B
101 104 21 DBH 1.36  
<TS 1618 B
101 130 12 04C 0.46  
<TS 1619 B
101 136 16 03H 0.92  
<TS 1620 B
101 138 14 03H 0.86  
<TS 1621 B
101 138 11 VS4  
-0.88  
<TS 1622 B
102 29 13 04C 0.84  
<TS 1623 B
102 31 18 02C  
-0.89  
<TS 1624 B
102 33 22 03C  
-0.89  
<TS 1625 B
102 35 22 03C 0.89  
<TS 1626 B
102 37 11 02C  
-0.88  
<TS 1627 B
102 41 18 06H 0.86  
<TS 1628 B
102 41 9
06H  
-0.86  
<TS 1629 B
102 49 14 VS2 0.82  
<TS 1630 B
102 51 18 07C 0.88  
<TS 1631 B
102 85 28 VS6  
-0.83  
<TS 1632 B
102 93 11 04C  
-0.15  
<TS 1633 B
102 93 10 04C  
-0.92  
<TS 1634 B
102 99 17 07C 0.9  
<TS 1635 B
102 99 11 07C 0.07  
<TS 1636 B
102 113 14 DBH 1.67  
<TS 1637 B
102 123 11 04H 0.92  
<TS 1638 B
102 127 13 VS4 0.81  
<TS 133 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1639   B       102     131       14       DBC       1.32   <TS 1640   B       102     137       13       VS4       -0.86   <TS 1641   B       102     137       19       VS4       0.92   <TS 1642   B       103       30       14       06C       -0.86   <TS 1643   B       103       30       12       01C       0.11   <TS 1644   B       103       36       13       07H       0.97   <TS 1645   B       103       36       14       07C       0.88   <TS 1646   B       103       38       14       02C       -0.86   <TS 1647   B       103       48       17       VS4       -0.86   <TS 1648   B       103       48         9       DBC       -1.3   <TS 1649   B       103       48       12       07C       -0.02   <TS 1650   B       103       58       16       VS2       -0.9   <TS 1651   B       103       62       16       03C       0.86   <TS 1652   B       103       64       28       VS2       0.81   <TS 1653   B       103       82       13       VS2       0.82   <TS 1654   B       103       94       19       VS2       -0.9   <TS 1655   B       103     100       15       07C       0.86   <TS 1656   B       103     108       23       VS6       -0.74   <TS 1657   B       103     120       19       03H       0.92   <TS 1658   B       103     120         8       03H       -0.93   <TS 1659   B       103     122       20       03H         0.9   <TS 1660   B       103     126       18       04H       0.93   <TS 1661   B       103     126       24       VS2       0.15   <TS 1662   B       103     126       19       VS4       -0.7   <TS 1663   B       103     126       35       VS6       0.83   <TS 1664   B       103     128       14       04C         0.9   <TS 1665   B       103     130       20       VS2       -0.13   <TS 1666   B       103     130       11       VS2       0.77   <TS 1667   B       103     132       20       VS2       -0.04   <TS 1668   B       103     132       12       04H       0.96   <TS 1669   B       103     136       19       VS4       -0.88   <TS 1670   B       103     136       23       VS4       0.88   <TS 1671   B       104       31       20       VS4       0.82   <TS 1672   B       104       31       10       DBC       -1.59   <TS 1673   B       104       31       16       02C       -0.2   <TS 1674   B       104       33       12       03H       0.13   <TS 1675   B       104       59       13       VS4       0.94   <TS 1676   B       104       59       12       VS6       -0.9   <TS 1677   B       104       79       12       VS6       -0.83   <TS 134 of 156
Percent No SG Row Column in Depth Location Elevation TS 1639 B
102 131 14 DBC 1.32  
<TS 1640 B
102 137 13 VS4  
-0.86  
<TS 1641 B
102 137 19 VS4 0.92  
<TS 1642 B
103 30 14 06C  
-0.86  
<TS 1643 B
103 30 12 01C 0.11  
<TS 1644 B
103 36 13 07H 0.97  
<TS 1645 B
103 36 14 07C 0.88  
<TS 1646 B
103 38 14 02C  
-0.86  
<TS 1647 B
103 48 17 VS4  
-0.86  
<TS 1648 B
103 48 9
DBC  
-1.3  
<TS 1649 B
103 48 12 07C  
-0.02  
<TS 1650 B
103 58 16 VS2  
-0.9  
<TS 1651 B
103 62 16 03C 0.86  
<TS 1652 B
103 64 28 VS2 0.81  
<TS 1653 B
103 82 13 VS2 0.82  
<TS 1654 B
103 94 19 VS2  
-0.9  
<TS 1655 B
103 100 15 07C 0.86  
<TS 1656 B
103 108 23 VS6  
-0.74  
<TS 1657 B
103 120 19 03H 0.92  
<TS 1658 B
103 120 8
03H  
-0.93  
<TS 1659 B
103 122 20 03H 0.9  
<TS 1660 B
103 126 18 04H 0.93  
<TS 1661 B
103 126 24 VS2 0.15  
<TS 1662 B
103 126 19 VS4  
-0.7  
<TS 1663 B
103 126 35 VS6 0.83  
<TS 1664 B
103 128 14 04C 0.9  
<TS 1665 B
103 130 20 VS2  
-0.13  
<TS 1666 B
103 130 11 VS2 0.77  
<TS 1667 B
103 132 20 VS2  
-0.04  
<TS 1668 B
103 132 12 04H 0.96  
<TS 1669 B
103 136 19 VS4  
-0.88  
<TS 1670 B
103 136 23 VS4 0.88  
<TS 1671 B
104 31 20 VS4 0.82  
<TS 1672 B
104 31 10 DBC  
-1.59  
<TS 1673 B
104 31 16 02C  
-0.2  
<TS 1674 B
104 33 12 03H 0.13  
<TS 1675 B
104 59 13 VS4 0.94  
<TS 1676 B
104 59 12 VS6  
-0.9  
<TS 1677 B
104 79 12 VS6  
-0.83  
<TS 134 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1678   B       104     91         13       VS2       -0.79   <TS 1679   B       104     95         20       VS2       -0.73   <TS 1680   B       104     95         14       VS2       -0.09   <TS 1681   B       104     95         18       VS2       0.73   <TS 1682   B       104     117       13       05C         0.9   <TS 1683   B       104     127       10       04H       0.82   <TS 1684   B       104     129       14       06C       0.83   <TS 1685   B       104     131       15       03C       0.85   <TS 1686   B       104     133         8       05C         0.9   <TS 1687   B       104     135       14       VS4       0.95   <TS 1688   B       105     30         14       VS4       0.15   <TS 1689   B       105     30         31       VS4       0.71   <TS 1690   B       105     30         20       02C       0.79   <TS 1691   B       105     32         9       VS4       -1.04   <TS 1692   B       105     32         13       VS4       1.02   <TS 1693   B       105     32         11       01H       0.91   <TS 1694   B       105     34         16       07C       -0.96   <TS 1695   B       105     34         16       03C       -0.91   <TS 1696   B       105     34         23       02C       0.13   <TS 1697   B       105     36         11       04H       -0.19   <TS 1698   B       105     38         18       03C       0.89   <TS 1699   B       105     40         12       03C       -0.91   <TS 1700   B       105     42         12       07C         0.9   <TS 1701   B       105     54         24       VS6       -0.88   <TS 1702   B       105     58         21       VS2       -0.9   <TS 1703   B       105     58         12       VS2       0.96   <TS 1704   B       105     58         17       VS4       -0.7   <TS 1705   B       105     58         16       VS4       0.11   <TS 1706   B       105     58         21       VS6       0.77   <TS 1707   B       105     68         15       VS2         0   <TS 1708   B       105     76         15       VS2       1.05   <TS 1709   B       105     78         9       VS2       -0.26   <TS 1710   B       105     78         11       VS2       1.06   <TS 1711   B       105     78         25       VS6       -0.75   <TS 1712   B       105     78         26       VS6       0.99   <TS 1713   B       105     80         24       VS2       -0.24   <TS 1714   B       105     88         10       VS2       -0.97   <TS 1715   B       105     88         8       07C       -0.13   <TS 1716   B       105     88         12       07C       -0.81   <TS 135 of 156
Percent No SG Row Column in Depth Location Elevation TS 1678 B
104 91 13 VS2  
-0.79  
<TS 1679 B
104 95 20 VS2  
-0.73  
<TS 1680 B
104 95 14 VS2  
-0.09  
<TS 1681 B
104 95 18 VS2 0.73  
<TS 1682 B
104 117 13 05C 0.9  
<TS 1683 B
104 127 10 04H 0.82  
<TS 1684 B
104 129 14 06C 0.83  
<TS 1685 B
104 131 15 03C 0.85  
<TS 1686 B
104 133 8
05C 0.9  
<TS 1687 B
104 135 14 VS4 0.95  
<TS 1688 B
105 30 14 VS4 0.15  
<TS 1689 B
105 30 31 VS4 0.71  
<TS 1690 B
105 30 20 02C 0.79  
<TS 1691 B
105 32 9
VS4  
-1.04  
<TS 1692 B
105 32 13 VS4 1.02  
<TS 1693 B
105 32 11 01H 0.91  
<TS 1694 B
105 34 16 07C  
-0.96  
<TS 1695 B
105 34 16 03C  
-0.91  
<TS 1696 B
105 34 23 02C 0.13  
<TS 1697 B
105 36 11 04H  
-0.19  
<TS 1698 B
105 38 18 03C 0.89  
<TS 1699 B
105 40 12 03C  
-0.91  
<TS 1700 B
105 42 12 07C 0.9  
<TS 1701 B
105 54 24 VS6  
-0.88  
<TS 1702 B
105 58 21 VS2  
-0.9  
<TS 1703 B
105 58 12 VS2 0.96  
<TS 1704 B
105 58 17 VS4  
-0.7  
<TS 1705 B
105 58 16 VS4 0.11  
<TS 1706 B
105 58 21 VS6 0.77  
<TS 1707 B
105 68 15 VS2 0  
<TS 1708 B
105 76 15 VS2 1.05  
<TS 1709 B
105 78 9
VS2  
-0.26  
<TS 1710 B
105 78 11 VS2 1.06  
<TS 1711 B
105 78 25 VS6  
-0.75  
<TS 1712 B
105 78 26 VS6 0.99  
<TS 1713 B
105 80 24 VS2  
-0.24  
<TS 1714 B
105 88 10 VS2  
-0.97  
<TS 1715 B
105 88 8
07C  
-0.13  
<TS 1716 B
105 88 12 07C  
-0.81  
<TS 135 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1717   B       105     90         16       VS2       0.88   <TS 1718   B       105     90         19       VS4       0.92   <TS 1719   B       105     90         17       07C       0.92   <TS 1720   B       105     90         17       03C       0.53   <TS 1721   B       105     96         13       04C       -0.92   <TS 1722   B       105     110       23       DBH       0.99   <TS 1723   B       105     116       17       03H       0.79   <TS 1724   B       105     118       11       03H       0.83   <TS 1725   B       105     118       12       DBH       1.84   <TS 1726   B       105     120       16       03H       -0.91   <TS 1727   B       105     130       21       03C       0.93   <TS 1728   B       105     130       13       VS2       0.29   <TS 1729   B       105     130       15       VS2       -0.73   <TS 1730   B       105     132       11       04H         0.9   <TS 1731   B       105     134       18       VS4       1.03   <TS 1732   B       105     134       22       02C         0.9   <TS 1733   B       105     136       12       01H       0.93   <TS 1734   B       105     136       11       VS4       -0.99   <TS 1735   B       106     31         27       VS4       0.82   <TS 1736   B       106     31         20       03C       0.89   <TS 1737   B       106     31         17       02C       0.84   <TS 1738   B       106     31         17       VS4       0.18   <TS 1739   B       106     33         12       VS4       -0.73   <TS 1740   B       106     33         15       03C       0.11   <TS 1741   B       106     35         15       03H       0.84   <TS 1742   B       106     35         19       04H       0.86   <TS 1743   B       106     35         16       03C         0.8   <TS 1744   B       106     35         16       02C       -0.18   <TS 1745   B       106     37         20       VS2       -0.69   <TS 1746   B       106     39         24       VS2         -1   <TS 1747   B       106     39         25       03C       0.91   <TS 1748   B       106     49         11       04H       -0.09   <TS 1749   B       106     51         17       07C         0.9   <TS 1750   B       106     51         12       VS2         1   <TS 1751   B       106     57         19       VS2       0.94   <TS 1752   B       106     63         13       VS4       -0.92   <TS 1753   B       106     63         24       VS2         0   <TS 1754   B       106     71         13       VS2       -0.44   <TS 1755   B       106     75         15       VS2       1.05   <TS 136 of 156
Percent No SG Row Column in Depth Location Elevation TS 1717 B
105 90 16 VS2 0.88  
<TS 1718 B
105 90 19 VS4 0.92  
<TS 1719 B
105 90 17 07C 0.92  
<TS 1720 B
105 90 17 03C 0.53  
<TS 1721 B
105 96 13 04C  
-0.92  
<TS 1722 B
105 110 23 DBH 0.99  
<TS 1723 B
105 116 17 03H 0.79  
<TS 1724 B
105 118 11 03H 0.83  
<TS 1725 B
105 118 12 DBH 1.84  
<TS 1726 B
105 120 16 03H  
-0.91  
<TS 1727 B
105 130 21 03C 0.93  
<TS 1728 B
105 130 13 VS2 0.29  
<TS 1729 B
105 130 15 VS2  
-0.73  
<TS 1730 B
105 132 11 04H 0.9  
<TS 1731 B
105 134 18 VS4 1.03  
<TS 1732 B
105 134 22 02C 0.9  
<TS 1733 B
105 136 12 01H 0.93  
<TS 1734 B
105 136 11 VS4  
-0.99  
<TS 1735 B
106 31 27 VS4 0.82  
<TS 1736 B
106 31 20 03C 0.89  
<TS 1737 B
106 31 17 02C 0.84  
<TS 1738 B
106 31 17 VS4 0.18  
<TS 1739 B
106 33 12 VS4  
-0.73  
<TS 1740 B
106 33 15 03C 0.11  
<TS 1741 B
106 35 15 03H 0.84  
<TS 1742 B
106 35 19 04H 0.86  
<TS 1743 B
106 35 16 03C 0.8  
<TS 1744 B
106 35 16 02C  
-0.18  
<TS 1745 B
106 37 20 VS2  
-0.69  
<TS 1746 B
106 39 24 VS2  
-1  
<TS 1747 B
106 39 25 03C 0.91  
<TS 1748 B
106 49 11 04H  
-0.09  
<TS 1749 B
106 51 17 07C 0.9  
<TS 1750 B
106 51 12 VS2 1  
<TS 1751 B
106 57 19 VS2 0.94  
<TS 1752 B
106 63 13 VS4  
-0.92  
<TS 1753 B
106 63 24 VS2 0  
<TS 1754 B
106 71 13 VS2  
-0.44  
<TS 1755 B
106 75 15 VS2 1.05  
<TS 136 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1756   B       106       77         23       VS2       0.88   <TS 1757   B       106     101         15       VS2       -0.75   <TS 1758   B       106     101         11       VS2       -0.26   <TS 1759   B       106     113         17       VS2         0   <TS 1760   B       106     129         17       04C       0.86   <TS 1761   B       106     131         14       03C       -0.18   <TS 1762   B       107       32         15       VS4       -0.84   <TS 1763   B       107       34         11       VS6       -0.86   <TS 1764   B       107       36         22       VS2       0.86   <TS 1765   B       107       36         15       VS6       -0.73   <TS 1766   B       107       36         11       VS6       0.11   <TS 1767   B       107       40         16       VS2       0.91   <TS 1768   B       107       42         33       VS2       -0.93   <TS 1769   B       107       42         36       VS2       0.93   <TS 1770   B       107       42         23       VS4       0.27   <TS 1771   B       107       42         33       VS4       0.82   <TS 1772   B       107       42         20       VS6       -0.86   <TS 1773   B       107       42         14       VS6       0.93   <TS 1774   B       107       44         18       07C       0.13   <TS 1775   B       107       44         15       06C       -0.15   <TS 1776   B       107       46         20       VS6       -0.88   <TS 1777   B       107     46           9       VS6       0.77   <TS 1778   B       107       52         17       VS6       -0.55   <TS 1779   B       107       52         15       07C       0.88   <TS 1780   B       107       58         15       DBH       1.47   <TS 1781   B       107       74         12       060       -0.88   <TS 1782   B       107       78         13       VS2       -0.88   <TS 1783   B       107       78         17       VS2       0.97   <TS 1784   B       107       82         32       VS2       -0.92   <TS 1785   B       107       82         29       VS2       0.97   <TS 1786   B       107       82         13       VS4       0.13   <TS 1787   B       107       96         24       VS2       0.99   <TS 1788   B       107       96         13       VS4       0.07   <TS 1789   B       107     114         9       VS2       0.26   <TS 1790   B       107     116         29       VS2       -0.83   <TS 1791   B       107     116         28       VS2       0.09   <TS 1792   B       107     116         29       VS2       0.79   <TS 1793   B       107     120         20       DBC       1.61   <TS 1794   B       107     124         13       04C       0.83   <TS 137 of 156
Percent No SG Row Column in Depth Location Elevation TS 1756 B
106 77 23 VS2 0.88  
<TS 1757 B
106 101 15 VS2  
-0.75  
<TS 1758 B
106 101 11 VS2  
-0.26  
<TS 1759 B
106 113 17 VS2 0  
<TS 1760 B
106 129 17 04C 0.86  
<TS 1761 B
106 131 14 03C  
-0.18  
<TS 1762 B
107 32 15 VS4  
-0.84  
<TS 1763 B
107 34 11 VS6  
-0.86  
<TS 1764 B
107 36 22 VS2 0.86  
<TS 1765 B
107 36 15 VS6  
-0.73  
<TS 1766 B
107 36 11 VS6 0.11  
<TS 1767 B
107 40 16 VS2 0.91  
<TS 1768 B
107 42 33 VS2  
-0.93  
<TS 1769 B
107 42 36 VS2 0.93  
<TS 1770 B
107 42 23 VS4 0.27  
<TS 1771 B
107 42 33 VS4 0.82  
<TS 1772 B
107 42 20 VS6  
-0.86  
<TS 1773 B
107 42 14 VS6 0.93  
<TS 1774 B
107 44 18 07C 0.13  
<TS 1775 B
107 44 15 06C  
-0.15  
<TS 1776 B
107 46 20 VS6  
-0.88  
<TS 1777 B
107 46 9
VS6 0.77  
<TS 1778 B
107 52 17 VS6  
-0.55  
<TS 1779 B
107 52 15 07C 0.88  
<TS 1780 B
107 58 15 DBH 1.47  
<TS 1781 B
107 74 12 060  
-0.88  
<TS 1782 B
107 78 13 VS2  
-0.88  
<TS 1783 B
107 78 17 VS2 0.97  
<TS 1784 B
107 82 32 VS2  
-0.92  
<TS 1785 B
107 82 29 VS2 0.97  
<TS 1786 B
107 82 13 VS4 0.13  
<TS 1787 B
107 96 24 VS2 0.99  
<TS 1788 B
107 96 13 VS4 0.07  
<TS 1789 B
107 114 9
VS2 0.26  
<TS 1790 B
107 116 29 VS2  
-0.83  
<TS 1791 B
107 116 28 VS2 0.09  
<TS 1792 B
107 116 29 VS2 0.79  
<TS 1793 B
107 120 20 DBC 1.61  
<TS 1794 B
107 124 13 04C 0.83  
<TS 137 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 1795   B       107       130       16       02H       0.89   <TS 1796   B       107       130       21       03H       0.86   <TS 1797   B       107       132       16       07C       0.92   <TS 1798   B       107       132       23       04C       0.79   <TS 1799   B       107       132       33       03C       0.81   <TS 1800   B       107       132       19       02C       0.87   <TS 1801   B       108       33       34       VS4       0.91   <TS 1802   B       108       33       15       DBH       -1.33   <TS 1803   B       108       33       25       08H       0.62   <TS 1804   B       108       35       25       04H       0.86   <TS 1805   B       108       35       14       VS2       -0.88   <TS 1806   B       108       35       14       VS2       0.93   <TS 1807   B       108       35         18       VS4       -0.8   <TS 1808   B       108       35         12       VS4       0.73   <TS 1809   B       108       35         16       04C       0.88   <TS 1810   B       108       35         18       04C       -0.91   <TS 1811   B       108       37         11       04C       -0.93   <TS 1812   B       108       37         24       03C       -0.33   <TS 1813   B       108       37         13       02C       0.88   <TS 1814   B       108       43         20       VS4       -0.86   <TS 1815   B       108       45         15       07C       0.84   <TS 1816   B       108       47         25       VS2       -0.71   <TS 1817   B       108       49         12       05H       0.94   <TS 1818   B       108       51         25       VS2       -0.73   <TS 1819   B       108       51         15       VS2       0.92   <TS 1820   B       108       59         18       VS2       -0.81   <TS 1821   B       108       59         18       VS2       0.86   <TS 1822   B       108       63         12       07H       0.13   <TS 1823   B       108       69         14       05H       0.89   <TS 1824   B       108       95         16       04C       0.84   <TS 1825   B       108       103       13       VS2       -0.79   <TS 1826   B       108       103       13       07C         0.9   <TS 1827   B       108       111       14       VS2       -0.15   <TS 1828   B       108       113       21       VS4       -0.92   <TS 1829   B       108       113       22       VS4         0.9   <TS 1830   B       108       115       17       07C         0.9   <TS 1831   B       108       129       11       04H       -0.06   <TS 1832   B       108       131       21       02C         0.9   <TS 1833   B       108       131       15       03C       0.04   <TS 138 of 156
Percent No SG Row Column in Depth Location Elevation TS 1795 B
107 130 16 02H 0.89  
<TS 1796 B
107 130 21 03H 0.86  
<TS 1797 B
107 132 16 07C 0.92  
<TS 1798 B
107 132 23 04C 0.79  
<TS 1799 B
107 132 33 03C 0.81  
<TS 1800 B
107 132 19 02C 0.87  
<TS 1801 B
108 33 34 VS4 0.91  
<TS 1802 B
108 33 15 DBH  
-1.33  
<TS 1803 B
108 33 25 08H 0.62  
<TS 1804 B
108 35 25 04H 0.86  
<TS 1805 B
108 35 14 VS2  
-0.88  
<TS 1806 B
108 35 14 VS2 0.93  
<TS 1807 B
108 35 18 VS4  
-0.8  
<TS 1808 B
108 35 12 VS4 0.73  
<TS 1809 B
108 35 16 04C 0.88  
<TS 1810 B
108 35 18 04C  
-0.91  
<TS 1811 B
108 37 11 04C  
-0.93  
<TS 1812 B
108 37 24 03C  
-0.33  
<TS 1813 B
108 37 13 02C 0.88  
<TS 1814 B
108 43 20 VS4  
-0.86  
<TS 1815 B
108 45 15 07C 0.84  
<TS 1816 B
108 47 25 VS2  
-0.71  
<TS 1817 B
108 49 12 05H 0.94  
<TS 1818 B
108 51 25 VS2  
-0.73  
<TS 1819 B
108 51 15 VS2 0.92  
<TS 1820 B
108 59 18 VS2  
-0.81  
<TS 1821 B
108 59 18 VS2 0.86  
<TS 1822 B
108 63 12 07H 0.13  
<TS 1823 B
108 69 14 05H 0.89  
<TS 1824 B
108 95 16 04C 0.84  
<TS 1825 B
108 103 13 VS2  
-0.79  
<TS 1826 B
108 103 13 07C 0.9  
<TS 1827 B
108 111 14 VS2  
-0.15  
<TS 1828 B
108 113 21 VS4  
-0.92  
<TS 1829 B
108 113 22 VS4 0.9  
<TS 1830 B
108 115 17 07C 0.9  
<TS 1831 B
108 129 11 04H  
-0.06  
<TS 1832 B
108 131 21 02C 0.9  
<TS 1833 B
108 131 15 03C 0.04  
<TS 138 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1834   B       108     133         18       02C       0.13   <TS 1835   B       109       34         22       VS4       -0.78   <TS 1836   B       109       34         23       04C       0.11   <TS 1837   B       109       40         19       VS2       -0.84   <TS 1838   B       109       40         19       VS2       1.13   <TS 1839   B       109       40         23       VS4       0.02   <TS 1840   B       109       48         12       VS4       -0.95   <TS 1841   B       109       52         18       VS2       -0.88   <TS 1842   B       109       52         37       VS2       0.95   <TS 1843   B       109       52         14       VS6       0.99   <TS 1844   B       109       54         12       06H       0.81   <TS 1845   B       109       62         18       07C       0.83   <TS 1846   B       109       64         12       08C       -0.89   <TS 1847   B       109       78         18       04C       -0.97   <TS 1848   B       109       84         11       04H       -0.13   <TS 1849   B       109       92         12       07C       0.88   <TS 1850   B       109       96         15       VS2       -0.9   <TS 1851   B       109     104         27       VS2       0.92   <TS 1852   B       109     112         19       07H         0.9   <TS 1853   B       109     112         15       VS2         -1   <TS 1854   B       109     112         16       07C       0.87   <TS 1855   B       109     112         9       06C       0.81   <TS 1856   B       109     114         14       VS2       -0.72   <TS 1857   B       109     114         28       VS2       -0.15   <TS 1858   B       109     114         16       VS2       0.15   <TS 1859   B       109     114         37       VS4       -0.87   <TS 1860   B       109     114         31       VS6       -0.9   <TS 1861   B       109     114         10       VS6       0.68   <TS 1862   B       109     120         15       04C       -0.94   <TS 1863   B       109     126         21       04H       0.85   <TS 1864   B       109     128         15       04H       0.87   <TS 1865   B       109     130         26       02C         0.8   <TS 1866   B       109     130         16       03C       0.95   <TS 1867   B       109     130         13       04C       0.88   <TS 1868   B       109     132         21       04C         0   <TS 1869   B       109     132         18       05C       0.81   <TS 1870   B       109     132         13       08C       -0.48   <TS 1871   B       109     132         10       DBH       1.19   <TS 1872   B       110       37         13       03C       -0.84   <TS 139 of 156
Percent No SG Row Column in Depth Location Elevation TS 1834 B
108 133 18 02C 0.13  
<TS 1835 B
109 34 22 VS4  
-0.78  
<TS 1836 B
109 34 23 04C 0.11  
<TS 1837 B
109 40 19 VS2  
-0.84  
<TS 1838 B
109 40 19 VS2 1.13  
<TS 1839 B
109 40 23 VS4 0.02  
<TS 1840 B
109 48 12 VS4  
-0.95  
<TS 1841 B
109 52 18 VS2  
-0.88  
<TS 1842 B
109 52 37 VS2 0.95  
<TS 1843 B
109 52 14 VS6 0.99  
<TS 1844 B
109 54 12 06H 0.81  
<TS 1845 B
109 62 18 07C 0.83  
<TS 1846 B
109 64 12 08C  
-0.89  
<TS 1847 B
109 78 18 04C  
-0.97  
<TS 1848 B
109 84 11 04H  
-0.13  
<TS 1849 B
109 92 12 07C 0.88  
<TS 1850 B
109 96 15 VS2  
-0.9  
<TS 1851 B
109 104 27 VS2 0.92  
<TS 1852 B
109 112 19 07H 0.9  
<TS 1853 B
109 112 15 VS2  
-1  
<TS 1854 B
109 112 16 07C 0.87  
<TS 1855 B
109 112 9
06C 0.81  
<TS 1856 B
109 114 14 VS2  
-0.72  
<TS 1857 B
109 114 28 VS2  
-0.15  
<TS 1858 B
109 114 16 VS2 0.15  
<TS 1859 B
109 114 37 VS4  
-0.87  
<TS 1860 B
109 114 31 VS6  
-0.9  
<TS 1861 B
109 114 10 VS6 0.68  
<TS 1862 B
109 120 15 04C  
-0.94  
<TS 1863 B
109 126 21 04H 0.85  
<TS 1864 B
109 128 15 04H 0.87  
<TS 1865 B
109 130 26 02C 0.8  
<TS 1866 B
109 130 16 03C 0.95  
<TS 1867 B
109 130 13 04C 0.88  
<TS 1868 B
109 132 21 04C 0  
<TS 1869 B
109 132 18 05C 0.81  
<TS 1870 B
109 132 13 08C  
-0.48  
<TS 1871 B
109 132 10 DBH 1.19  
<TS 1872 B
110 37 13 03C  
-0.84  
<TS 139 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1873   B       110       37         17       04C       -0.82   <TS 1874   B       110       41         13       02C       0.09   <TS 1875   B       110       51         12       05H       0.89   <TS 1876   B       110       55         31       VS2       -0.86   <TS 1877   B       110       55         13       VS2       0.84   <TS 1878   B       110       69         9       06H       -0.82   <TS 1879   B       110       79         20       VS2       -0.02   <TS 1880   B       110       97         17       VS2       -0.81   <TS 1881   B       110       97         16       08H         1.6   <TS 1882   B       110     115         14       03H       -0.87   <TS 1883   B       110     131         18       02C       0.85   <TS 1884   B       110     131         11       02C       -0.91   <TS 1885   B       110     131         26       03C       0.84   <TS 1886   B       110     131         13       03C       -0.94   <TS 1887   B       111       40         10       DBC       -1.64   <TS 1888   B       111       50         20       VS2       0.86   <TS 1889   B       111       56         14       08H       0.07   <TS 1890   B       111       66         9       07H       0.81   <TS 1891   B       111       74         13       05H       0.87   <TS 1892   B       111       84         11       04H       -0.89   <TS 1893   B       111     118         14       04H       0.88   <TS 1894   B       111     120         14       04H         0.9   <TS 1895   B       111     122         12       03C       -0.13   <TS 1896   B       111     122         14       03C       -0.93   <TS 1897   B       111     126         16       03C       0.85   <TS 1898   B       111     128         12       03H       -0.8   <TS 1899   B       111     130         17       02H       0.15   <TS 1900   B       111     130         26       VS4       0.88   <TS 1901   B       112       37         32       04C       -0.95   <TS 1902   B       112       39         12       02H       0.88   <TS 1903   B       112       43         21       VS2       -0.89   <TS 1904   B       112       43         18       VS2       1.02   <TS 1905   B       112       43         16       VS4       -0.84   <TS 1906   B       112       45         13       VS2       -0.86   <TS 1907   B       112       45         10       03H       0.84   <TS 1908   B       112       47         28       VS2       -0.86   <TS 1909   B       112       47         17       VS2       0.93   <TS 1910   B       112       47         24       VS4       0.99   <TS 1911   B       112       49         10       VS4       0.46   <TS 140 of 156
Percent No SG Row Column in Depth Location Elevation TS 1873 B
110 37 17 04C  
-0.82  
<TS 1874 B
110 41 13 02C 0.09  
<TS 1875 B
110 51 12 05H 0.89  
<TS 1876 B
110 55 31 VS2  
-0.86  
<TS 1877 B
110 55 13 VS2 0.84  
<TS 1878 B
110 69 9
06H  
-0.82  
<TS 1879 B
110 79 20 VS2  
-0.02  
<TS 1880 B
110 97 17 VS2  
-0.81  
<TS 1881 B
110 97 16 08H 1.6  
<TS 1882 B
110 115 14 03H  
-0.87  
<TS 1883 B
110 131 18 02C 0.85  
<TS 1884 B
110 131 11 02C  
-0.91  
<TS 1885 B
110 131 26 03C 0.84  
<TS 1886 B
110 131 13 03C  
-0.94  
<TS 1887 B
111 40 10 DBC  
-1.64  
<TS 1888 B
111 50 20 VS2 0.86  
<TS 1889 B
111 56 14 08H 0.07  
<TS 1890 B
111 66 9
07H 0.81  
<TS 1891 B
111 74 13 05H 0.87  
<TS 1892 B
111 84 11 04H  
-0.89  
<TS 1893 B
111 118 14 04H 0.88  
<TS 1894 B
111 120 14 04H 0.9  
<TS 1895 B
111 122 12 03C  
-0.13  
<TS 1896 B
111 122 14 03C  
-0.93  
<TS 1897 B
111 126 16 03C 0.85  
<TS 1898 B
111 128 12 03H  
-0.8  
<TS 1899 B
111 130 17 02H 0.15  
<TS 1900 B
111 130 26 VS4 0.88  
<TS 1901 B
112 37 32 04C  
-0.95  
<TS 1902 B
112 39 12 02H 0.88  
<TS 1903 B
112 43 21 VS2  
-0.89  
<TS 1904 B
112 43 18 VS2 1.02  
<TS 1905 B
112 43 16 VS4  
-0.84  
<TS 1906 B
112 45 13 VS2  
-0.86  
<TS 1907 B
112 45 10 03H 0.84  
<TS 1908 B
112 47 28 VS2  
-0.86  
<TS 1909 B
112 47 17 VS2 0.93  
<TS 1910 B
112 47 24 VS4 0.99  
<TS 1911 B
112 49 10 VS4 0.46  
<TS 140 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 1912   B       112       53       16       VS2       -0.86   <TS 1913   B       112       53       14       VS2       0.92   <TS 1914   B       112       55       13       04H       -0.94   <TS 1915   B       112       57       11       VS2       -0.79   <TS 1916   B       112       59       12       VS2       0.81   <TS 1917   B       112       59       11       VS2       0.13   <TS 1918   B       112       71       14       VS2       -0.9   <TS 1919   B       112       79       19       04H       -0.82   <TS 1920   B       112       79       23       VS2       0.66   <TS 1921   B       112     119       12       03H       -0.88   <TS 1922   B       112     121       19       02C       0.84   <TS 1923   B       112     127       26       03C       0.15   <TS 1924   B       113       36       12       04H       -0.93   <TS 1925   B       113       36       13       08H       0.82   <TS 1926   B       113       36       16       VS2       0.78   <TS 1927   B       113       36       15       VS2       -0.67   <TS 1928   B       113       36       20       VS6       -0.89   <TS 1929   B       113       36       14       VS6       0.69   <TS 1930   B       113       36       18       02C         0.8   <TS 1931   B       113       38       11       VS4       -0.88   <TS 1932   B       113     40         21       03C       -0.61   <TS 1933   B       113     40         13       04H       -0.11   <TS 1934   B       113     40         17       VS4       -0.85   <TS 1935   B       113     42         11       05H       0.02   <TS 1936   B       113     42         15       VS4         0.9   <TS 1937   B       113     42         8       030       -0.15   <TS 1938   B       113     44         18       01H       0.89   <TS 1939   B       113     48         41       VS2       -0.91   PLG 1940   B       113     48         16       VS2       0.93   <TS 1941   B       113     48         36       VS4       -0.74   <TS 1942   B       113     48         8       VS4       0.65   <TS 1943   B       113     66         11       06H       0.83   <TS 1944   B       113       70       17       07C       0.86   <TS 1945   B       113       70       15       07C       0.11   <TS 1946   B       113     84         13       02H       -0.93   <TS 1947   B       113     84         12       04H       -0.86   <TS 1948   B       113     110       14       VS2       0.77   <TS 1949   B       113     110       17       04C         0.9   <TS 1950   B       113     122       12       03C       -1.04   <TS 141 of 156
Percent No SG Row Column in Depth Location Elevation TS 1912 B
112 53 16 VS2  
-0.86  
<TS 1913 B
112 53 14 VS2 0.92  
<TS 1914 B
112 55 13 04H  
-0.94  
<TS 1915 B
112 57 11 VS2  
-0.79  
<TS 1916 B
112 59 12 VS2 0.81  
<TS 1917 B
112 59 11 VS2 0.13  
<TS 1918 B
112 71 14 VS2  
-0.9  
<TS 1919 B
112 79 19 04H  
-0.82  
<TS 1920 B
112 79 23 VS2 0.66  
<TS 1921 B
112 119 12 03H  
-0.88  
<TS 1922 B
112 121 19 02C 0.84  
<TS 1923 B
112 127 26 03C 0.15  
<TS 1924 B
113 36 12 04H  
-0.93  
<TS 1925 B
113 36 13 08H 0.82  
<TS 1926 B
113 36 16 VS2 0.78  
<TS 1927 B
113 36 15 VS2  
-0.67  
<TS 1928 B
113 36 20 VS6  
-0.89  
<TS 1929 B
113 36 14 VS6 0.69  
<TS 1930 B
113 36 18 02C 0.8  
<TS 1931 B
113 38 11 VS4  
-0.88  
<TS 1932 B
113 40 21 03C  
-0.61  
<TS 1933 B
113 40 13 04H  
-0.11  
<TS 1934 B
113 40 17 VS4  
-0.85  
<TS 1935 B
113 42 11 05H 0.02  
<TS 1936 B
113 42 15 VS4 0.9  
<TS 1937 B
113 42 8
030  
-0.15  
<TS 1938 B
113 44 18 01H 0.89  
<TS 1939 B
113 48 41 VS2  
-0.91 PLG 1940 B
113 48 16 VS2 0.93  
<TS 1941 B
113 48 36 VS4  
-0.74  
<TS 1942 B
113 48 8
VS4 0.65  
<TS 1943 B
113 66 11 06H 0.83  
<TS 1944 B
113 70 17 07C 0.86  
<TS 1945 B
113 70 15 07C 0.11  
<TS 1946 B
113 84 13 02H  
-0.93  
<TS 1947 B
113 84 12 04H  
-0.86  
<TS 1948 B
113 110 14 VS2 0.77  
<TS 1949 B
113 110 17 04C 0.9  
<TS 1950 B
113 122 12 03C  
-1.04  
<TS 141 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 1951   B       113     130         19       VS4       -0.85   <TS 1952   B       114       37         15       04C       0.88   <TS 1953   B       114       37         30       VS4       0.97   <TS 1954   B       114       37         19       VS4       -0.73   <TS 1955   B       114       37         23       VS2       -0.75   <TS 1956   B       114       37         30       VS2       0.11   <TS 1957   B       114       37         25       DBH       1.26   <TS 1958   B       114       39         23       VS2       -0.88   <TS 1959   B       114       39         35       VS4         0.8   <TS 1960   B       114       39         12       02C         0.8   <TS 1961   B       114       43         10       07H       0.84   <TS 1962   B       114     119         14       VS4       0.96   <TS 1963   B       114     127         17       05C       0.83   <TS 1964   B       114     127         14       04C       0.86   <TS 1965   B       114     127         25       03C       0.83   <TS 1966   B       114     129         11       VS4       -0.78   <TS 1967   B       115       38         38       01C       0.38   <TS 1968   B       115       38         17       02C       0.93   <TS 1969   B       115       38         15       08H       0.88   <TS 1970   B       115       38         19       VS4       -0.8   <TS 1971   B       115       58         12       07H       -0.88   <TS 1972   B       115     68         10       05H       0.93   <TS 1973   B       115     84         13       03H       -0.86   <TS 1974   B       115     86         16       03H       0.93   <TS 1975   B       115     104         11       04H       -0.84   <TS 1976   B       115     114         13       07H       0.83   <TS 1977   B       115     122         15       07H         1   <TS 1978   B       115     124         17       05C       -0.92   <TS 1979   B       115     126         16       04H       0.93   <TS 1980   B       115     126         21       03C       0.83   <TS 1981   B       115     126         17       03C       -0.87   <TS 1982   B       116     43         19       VS4       0.93   <TS 1983   B       116     45         12       06H       0.95   <TS 1984   B       116     45         16       VS2       -0.04   <TS 1985   B       116     45         16       VS4       0.88   <TS 1986   B       116     47         15       VS4         0.9   <TS 1987   B       116     55         13       VS2       -0.88   <TS 1988   B       116     55         18       VS4       0.93   <TS 1989   B       116     55         14       04C       0.86   <TS 142 of 156
Percent No SG Row Column in Depth Location Elevation TS 1951 B
113 130 19 VS4  
-0.85  
<TS 1952 B
114 37 15 04C 0.88  
<TS 1953 B
114 37 30 VS4 0.97  
<TS 1954 B
114 37 19 VS4  
-0.73  
<TS 1955 B
114 37 23 VS2  
-0.75  
<TS 1956 B
114 37 30 VS2 0.11  
<TS 1957 B
114 37 25 DBH 1.26  
<TS 1958 B
114 39 23 VS2  
-0.88  
<TS 1959 B
114 39 35 VS4 0.8  
<TS 1960 B
114 39 12 02C 0.8  
<TS 1961 B
114 43 10 07H 0.84  
<TS 1962 B
114 119 14 VS4 0.96  
<TS 1963 B
114 127 17 05C 0.83  
<TS 1964 B
114 127 14 04C 0.86  
<TS 1965 B
114 127 25 03C 0.83  
<TS 1966 B
114 129 11 VS4  
-0.78  
<TS 1967 B
115 38 38 01C 0.38  
<TS 1968 B
115 38 17 02C 0.93  
<TS 1969 B
115 38 15 08H 0.88  
<TS 1970 B
115 38 19 VS4  
-0.8  
<TS 1971 B
115 58 12 07H  
-0.88  
<TS 1972 B
115 68 10 05H 0.93  
<TS 1973 B
115 84 13 03H  
-0.86  
<TS 1974 B
115 86 16 03H 0.93  
<TS 1975 B
115 104 11 04H  
-0.84  
<TS 1976 B
115 114 13 07H 0.83  
<TS 1977 B
115 122 15 07H 1  
<TS 1978 B
115 124 17 05C  
-0.92  
<TS 1979 B
115 126 16 04H 0.93  
<TS 1980 B
115 126 21 03C 0.83  
<TS 1981 B
115 126 17 03C  
-0.87  
<TS 1982 B
116 43 19 VS4 0.93  
<TS 1983 B
116 45 12 06H 0.95  
<TS 1984 B
116 45 16 VS2  
-0.04  
<TS 1985 B
116 45 16 VS4 0.88  
<TS 1986 B
116 47 15 VS4 0.9  
<TS 1987 B
116 55 13 VS2  
-0.88  
<TS 1988 B
116 55 18 VS4 0.93  
<TS 1989 B
116 55 14 04C 0.86  
<TS 142 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row     Column     in Depth   Location Elevation TS 1990   B       116       77       17       VS2       0.77   <TS 1991   B       116       81         18       VS7       -0.88   <TS 1992   B       116       81         10       07C       -0.15   <TS 1993   B       116       81         14       07C       -0.9   <TS 1994   B       116       93         10       04C       -0.96   <TS 1995   B       116       97         9       04C       -0.2   <TS 1996   B       116       103       20       05C       0.88   <TS 1997   B       116       111       15       05H       -0.96   <TS 1998   B       116       111         9       05H       0.96   <TS 1999   B       116       111       11       08C       0.87   <TS 2000   B       116       111       20       04C       -0.96   <TS 2001   B       116       115       22       VS4       0.85   <TS 2002   B       116       117       19       030       -0.15   <TS 2003   B       116       117       13       03C       -0.9   <TS 2004   B       116       125       14       05C       0.86   <TS 2005   B       116       125       15       04C       0.86   <TS 2006   B       116       125       11       040       0.02   <TS 2007   B       116       125       33       03C       1.05   <TS 2008   B       117       40         12       050       0.78   <TS 2009   B       117       40         21       03C       -0.89   <TS 2010   B       117       40       22       020       -0.84   <TS 2011   B       117       40       14       02C       -0.11   <TS 2012   B       117       40       11       01C       -0.86   <TS 2013   B       117       40       19       040       -0.2   <TS 2014   B       117       40       16       020         0.8   <TS 2015   B       117       44       15       02C       0.82   <TS 2016   B       117       48       15       030       -0.88   <TS 2017   B       117       66       10       06H       0.94   <TS 2018   B       117       66       13       070         0.9   <TS 2019   B       117       68       11       05H       0.98   <TS 2020   B       117       82         9       06H       -0.91   <TS 2021   B       117       90       14       VS4       0.29   <TS 2022   B       117       90       18       08C       0.92   <TS 2023   B       117       108       14       03H       -0.87   <TS 2024   B       117       108       13       04H       0.98   <TS 2025   B       117       112       19       04H         1   <TS 2026   B       118       41       14       02H       0.88   <TS 2027   B       118       41       14       03C       -0.22   <TS 2028   B       118       43       16       VS4         0.9   <TS 143 of 156
Percent No SG Row Column in Depth Location Elevation TS 1990 B
116 77 17 VS2 0.77  
<TS 1991 B
116 81 18 VS7  
-0.88  
<TS 1992 B
116 81 10 07C  
-0.15  
<TS 1993 B
116 81 14 07C  
-0.9  
<TS 1994 B
116 93 10 04C  
-0.96  
<TS 1995 B
116 97 9
04C  
-0.2  
<TS 1996 B
116 103 20 05C 0.88  
<TS 1997 B
116 111 15 05H  
-0.96  
<TS 1998 B
116 111 9
05H 0.96  
<TS 1999 B
116 111 11 08C 0.87  
<TS 2000 B
116 111 20 04C  
-0.96  
<TS 2001 B
116 115 22 VS4 0.85  
<TS 2002 B
116 117 19 030  
-0.15  
<TS 2003 B
116 117 13 03C  
-0.9  
<TS 2004 B
116 125 14 05C 0.86  
<TS 2005 B
116 125 15 04C 0.86  
<TS 2006 B
116 125 11 040 0.02  
<TS 2007 B
116 125 33 03C 1.05  
<TS 2008 B
117 40 12 050 0.78  
<TS 2009 B
117 40 21 03C  
-0.89  
<TS 2010 B
117 40 22 020  
-0.84  
<TS 2011 B
117 40 14 02C  
-0.11  
<TS 2012 B
117 40 11 01C  
-0.86  
<TS 2013 B
117 40 19 040  
-0.2  
<TS 2014 B
117 40 16 020 0.8  
<TS 2015 B
117 44 15 02C 0.82  
<TS 2016 B
117 48 15 030  
-0.88  
<TS 2017 B
117 66 10 06H 0.94  
<TS 2018 B
117 66 13 070 0.9  
<TS 2019 B
117 68 11 05H 0.98  
<TS 2020 B
117 82 9
06H  
-0.91  
<TS 2021 B
117 90 14 VS4 0.29  
<TS 2022 B
117 90 18 08C 0.92  
<TS 2023 B
117 108 14 03H  
-0.87  
<TS 2024 B
117 108 13 04H 0.98  
<TS 2025 B
117 112 19 04H 1  
<TS 2026 B
118 41 14 02H 0.88  
<TS 2027 B
118 41 14 03C  
-0.22  
<TS 2028 B
118 43 16 VS4 0.9  
<TS 143 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2029   B       118       43         17       VS6       -0.02   <TS 2030   B       118       73         12       VS6       -0.92   <TS 2031   B       118       73         12       VS7       -0.83   <TS 2032   B       118       87         14       VS2       0.94   <TS 2033   B       118       89         26       VS2       0.99   <TS 2034   B       118       89         16       VS4       0.68   <TS 2035   B       118       97         12       VS2       -0.9   <TS 2036   B       118     101         11       08C       0.86   <TS 2037   B       118     105         15       VS4       -0.55   <TS 2038   B       118     117         17       04C       -0.15   <TS 2039   B       118     121         11       03H       -0.88   <TS 2040   B       118     123         23       04C       -0.92   <TS 2041   B       118     123         14       03C       0.83   <TS 2042   B       118     123         13       02C       0.82   <TS 2043   B       119     42         14       02H       0.88   <TS 2044   B       119     42         19       VS7       -0.84   <TS 2045   B       119     42         14       05C       0.84   <TS 2046   B       119     42         22       04C       -0.48   <TS 2047   B       119     42         19       03C       0.46   <TS 2048   B       119     44         17       02H       0.81   <TS 2049   B       119     44         13       01C       0.78   <TS 2050   B       119     46         20       02C       0.79   <TS 2051   B       119     88         23       08C         0.9   <TS 2052   B       119     88           9       08C       -0.15   <TS 2053   B       119     104         14       VS1       -0.74   <TS 2054   B       119     110         16       04C       0.87   <TS 2055   B       119     112         19       04C       0.89   <TS 2056   B       119     112         16       03C       0.85   <TS 2057   B       119     112         12       03C       -0.86   <TS 2058   B       119     122         15       04H       -0.92   <TS 2059   B       120     43         11       02H       0.86   <TS 2060   B       120     43         19       01C       -0.91   <TS 2061   B       120     43           9       01C       0.86   <TS 2062   B       120     45         11       02C       0.77   <TS 2063   B       120     47         26       03C       0.86   <TS 2064   B       120     47           8       03C       -0.95   <TS 2065   B       120     49         11       03C       -0.9   <TS 2066   B       120     55         12       07C       -0.9   <TS 2067   B       120     61         14       08C         0.9   <TS 144 of 156
Percent No SG Row Column in Depth Location Elevation TS 2029 B
118 43 17 VS6  
-0.02  
<TS 2030 B
118 73 12 VS6  
-0.92  
<TS 2031 B
118 73 12 VS7  
-0.83  
<TS 2032 B
118 87 14 VS2 0.94  
<TS 2033 B
118 89 26 VS2 0.99  
<TS 2034 B
118 89 16 VS4 0.68  
<TS 2035 B
118 97 12 VS2  
-0.9  
<TS 2036 B
118 101 11 08C 0.86  
<TS 2037 B
118 105 15 VS4  
-0.55  
<TS 2038 B
118 117 17 04C  
-0.15  
<TS 2039 B
118 121 11 03H  
-0.88  
<TS 2040 B
118 123 23 04C  
-0.92  
<TS 2041 B
118 123 14 03C 0.83  
<TS 2042 B
118 123 13 02C 0.82  
<TS 2043 B
119 42 14 02H 0.88  
<TS 2044 B
119 42 19 VS7  
-0.84  
<TS 2045 B
119 42 14 05C 0.84  
<TS 2046 B
119 42 22 04C  
-0.48  
<TS 2047 B
119 42 19 03C 0.46  
<TS 2048 B
119 44 17 02H 0.81  
<TS 2049 B
119 44 13 01C 0.78  
<TS 2050 B
119 46 20 02C 0.79  
<TS 2051 B
119 88 23 08C 0.9  
<TS 2052 B
119 88 9
08C  
-0.15  
<TS 2053 B
119 104 14 VS1  
-0.74  
<TS 2054 B
119 110 16 04C 0.87  
<TS 2055 B
119 112 19 04C 0.89  
<TS 2056 B
119 112 16 03C 0.85  
<TS 2057 B
119 112 12 03C  
-0.86  
<TS 2058 B
119 122 15 04H  
-0.92  
<TS 2059 B
120 43 11 02H 0.86  
<TS 2060 B
120 43 19 01C  
-0.91  
<TS 2061 B
120 43 9
01C 0.86  
<TS 2062 B
120 45 11 02C 0.77  
<TS 2063 B
120 47 26 03C 0.86  
<TS 2064 B
120 47 8
03C  
-0.95  
<TS 2065 B
120 49 11 03C  
-0.9  
<TS 2066 B
120 55 12 07C  
-0.9  
<TS 2067 B
120 61 14 08C 0.9  
<TS 144 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2068   B       120     103         16       07H       0.97   <TS 2069   B       120     105         23       VS2       -0.83   <TS 2070   B       120     113         22       VS2       -0.94   <TS 2071   B       120     113         16       VS2       0.86   <TS 2072   B       120     115         26       03C       0.89   <TS 2073   B       120     121         12       03H       0.82   <TS 2074   B       121       44         18       01H       0.89   <TS 2075   B       121       44         13       03C       0.84   <TS 2076   B       121     104         14       03H       0.88   <TS 2077   B       121     104         18       05H         0.8   <TS 2078   B       121     104         12       04H       0.86   <TS 2079   B       121     114         13       03C       0.94   <TS 2080   B       121     114         18       VS4       -0.96   <TS 2081   B       121     114         13       04C       -0.92   <TS 2082   B       121     118         19       02C       0.82   <TS 2083   B       121     120         15       02C       -0.13   <TS 2084   B       121     122         11       02H       0.88   <TS 2085   B       122       71         11       05H       0.89   <TS 2086   B       122       71         11       VS2       -0.75   <TS 2087   B       122     111         10       06C       0.88   <TS 2088   B       123       52         16       02C       0.86   <TS 2089   B       123       72         13       VS4       -0.88   <TS 2090   B       123       72         13       VS7       0.88   <TS 2091   B       123       78         20       05H       -1.1   <TS 2092   B       123       84         11       04H       -0.13   <TS 2093   B       123       98         12       07C         0.9   <TS 2094   B       123       98         10       06C       0.81   <TS 2095   B       123     116         37       VS6       -0.76   <TS 2096   B       123     116         18       05C       -0.95   <TS 2097   B       123     116         12       04C       0.89   <TS 2098   B       123     116         11       03C       0.91   <TS 2099   B       123     118         35       VS6       -0.93   <TS 2100   B       123     118         22       VS7       -0.95   <TS 2101   B       123     118         14       08C       0.85   <TS 2102   B       124       47         13       03C       0.88   <TS 2103   B       124       47         9       01C       -0.13   <TS 2104   B       124       49         17       02C       -0.95   <TS 2105   B       124       51         13       VS4       0.64   <TS 2106   B       124       55         11       05H       -0.17   <TS 145 of 156
Percent No SG Row Column in Depth Location Elevation TS 2068 B
120 103 16 07H 0.97  
<TS 2069 B
120 105 23 VS2  
-0.83  
<TS 2070 B
120 113 22 VS2  
-0.94  
<TS 2071 B
120 113 16 VS2 0.86  
<TS 2072 B
120 115 26 03C 0.89  
<TS 2073 B
120 121 12 03H 0.82  
<TS 2074 B
121 44 18 01H 0.89  
<TS 2075 B
121 44 13 03C 0.84  
<TS 2076 B
121 104 14 03H 0.88  
<TS 2077 B
121 104 18 05H 0.8  
<TS 2078 B
121 104 12 04H 0.86  
<TS 2079 B
121 114 13 03C 0.94  
<TS 2080 B
121 114 18 VS4  
-0.96  
<TS 2081 B
121 114 13 04C  
-0.92  
<TS 2082 B
121 118 19 02C 0.82  
<TS 2083 B
121 120 15 02C  
-0.13  
<TS 2084 B
121 122 11 02H 0.88  
<TS 2085 B
122 71 11 05H 0.89  
<TS 2086 B
122 71 11 VS2  
-0.75  
<TS 2087 B
122 111 10 06C 0.88  
<TS 2088 B
123 52 16 02C 0.86  
<TS 2089 B
123 72 13 VS4  
-0.88  
<TS 2090 B
123 72 13 VS7 0.88  
<TS 2091 B
123 78 20 05H  
-1.1  
<TS 2092 B
123 84 11 04H  
-0.13  
<TS 2093 B
123 98 12 07C 0.9  
<TS 2094 B
123 98 10 06C 0.81  
<TS 2095 B
123 116 37 VS6  
-0.76  
<TS 2096 B
123 116 18 05C  
-0.95  
<TS 2097 B
123 116 12 04C 0.89  
<TS 2098 B
123 116 11 03C 0.91  
<TS 2099 B
123 118 35 VS6  
-0.93  
<TS 2100 B
123 118 22 VS7  
-0.95  
<TS 2101 B
123 118 14 08C 0.85  
<TS 2102 B
124 47 13 03C 0.88  
<TS 2103 B
124 47 9
01C  
-0.13  
<TS 2104 B
124 49 17 02C  
-0.95  
<TS 2105 B
124 51 13 VS4 0.64  
<TS 2106 B
124 55 11 05H  
-0.17  
<TS 145 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2107   B       124       57       12       VS7       -1.08   <TS 2108   B       124       73       12       VS2       0.83   <TS 2109   B       124       85       13       VS2       0.22   <TS 2110   B       124       85       12       VS2         0.7   <TS 2111   B       124       85       16       VS4       -0.66   <TS 2112   B       124       87       16       VS4       0.88   <TS 2113   B       124     93         17       VS1       0.61   <TS 2114   B       124     93         31       VS2         0   <TS 2115   B       124     93         11       VS2       0.72   <TS 2116   B       124     93         18       VS2       -0.72   <TS 2117   B       124     93         12       VS4       0.92   <TS 2118   B       124     95         20       VS2       -0.02   <TS 2119   B       124     95         15       VS4       -0.9   <TS 2120   B       124     95         20       VS4       0.92   <TS 2121   B       124     97         14       06C       0.86   <TS 2122   B       124     101       12       04C       -0.85   <TS 2123   B       124     105       13       06C       0.86   <TS 2124   B       124     111       10       02C       -0.13   <TS 2125   B       124     113       12       03C       0.87   <TS 2126   B       124     113         9       03C       -0.2   <TS 2127   B       124     117       13       VS4       0.78   <TS 2128   B       124     117       20       VS7       -0.2   <TS 2129   B       124     117       11       06C       0.83   <TS 2130   B       124     117       10       06C       -0.89   <TS 2131   B       124     117       21       04C       0.83   <TS 2132   B       124     119       12       08C       -0.15   <TS 2133   B       124     119       12       08C       0.91   <TS 2134   B       125     48         7       VS4       -1.01   <TS 2135   B       125     48         16       VS4         0.9   <TS 2136   B       125     48         16       VS6         0.9   <TS 2137   B       125     78         12       03H       -0.89   <TS 2138   B       125     82         11       05H       -0.87   <TS 2139   B       125     82         13       VS1       -0.79   <TS 2140   B       125     94         23       VS2       -0.7   <TS 2141   B       125     94         18       VS2       -0.15   <TS 2142   B       125     100       16       08C       0.88   <TS 2143   B       125     104       20       07H       0.86   <TS 2144   B       125     104       23       070       -0.2   <TS 2145   B       125     112       21       02C       0.85   <TS 146 of 156
Percent No SG Row Column in Depth Location Elevation TS 2107 B
124 57 12 VS7  
-1.08  
<TS 2108 B
124 73 12 VS2 0.83  
<TS 2109 B
124 85 13 VS2 0.22  
<TS 2110 B
124 85 12 VS2 0.7  
<TS 2111 B
124 85 16 VS4  
-0.66  
<TS 2112 B
124 87 16 VS4 0.88  
<TS 2113 B
124 93 17 VS1 0.61  
<TS 2114 B
124 93 31 VS2 0  
<TS 2115 B
124 93 11 VS2 0.72  
<TS 2116 B
124 93 18 VS2  
-0.72  
<TS 2117 B
124 93 12 VS4 0.92  
<TS 2118 B
124 95 20 VS2  
-0.02  
<TS 2119 B
124 95 15 VS4  
-0.9  
<TS 2120 B
124 95 20 VS4 0.92  
<TS 2121 B
124 97 14 06C 0.86  
<TS 2122 B
124 101 12 04C  
-0.85  
<TS 2123 B
124 105 13 06C 0.86  
<TS 2124 B
124 111 10 02C  
-0.13  
<TS 2125 B
124 113 12 03C 0.87  
<TS 2126 B
124 113 9
03C  
-0.2  
<TS 2127 B
124 117 13 VS4 0.78  
<TS 2128 B
124 117 20 VS7  
-0.2  
<TS 2129 B
124 117 11 06C 0.83  
<TS 2130 B
124 117 10 06C  
-0.89  
<TS 2131 B
124 117 21 04C 0.83  
<TS 2132 B
124 119 12 08C  
-0.15  
<TS 2133 B
124 119 12 08C 0.91  
<TS 2134 B
125 48 7
VS4  
-1.01  
<TS 2135 B
125 48 16 VS4 0.9  
<TS 2136 B
125 48 16 VS6 0.9  
<TS 2137 B
125 78 12 03H  
-0.89  
<TS 2138 B
125 82 11 05H  
-0.87  
<TS 2139 B
125 82 13 VS1  
-0.79  
<TS 2140 B
125 94 23 VS2  
-0.7  
<TS 2141 B
125 94 18 VS2  
-0.15  
<TS 2142 B
125 100 16 08C 0.88  
<TS 2143 B
125 104 20 07H 0.86  
<TS 2144 B
125 104 23 070  
-0.2  
<TS 2145 B
125 112 21 02C 0.85  
<TS 146 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2146   B       125     114       17       03C       0.85   <TS 2147   B       125     116       17       02H       0.89   <TS 2148   B       125     116       12       03H       0.83   <TS 2149   B       125     116       18       VS4       -0.87   <TS 2150   B       125     116         7       VS4       0.89   <TS 2151   B       125     118       13       05H       -1.04   <TS 2152   B       126       51       12       01C       0.83   <TS 2153   B       126       55       17       02C       0.88   <TS 2154   B       126       55       13       06H       0.92   <TS 2155   B       126       61       15       VS1       0.88   <TS 2156   B       126       81       11       VS4       -0.86   <TS 2157   B       126       83       17       VS1       -0.18   <TS 2158   B       126       91         8       VS4       -0.86   <TS 2159   B       126       91       21       VS2       0.04   <TS 2160   B       126       95       19       VS6       1.05   <TS 2161   B       126       95       25       VS4       -0.9   <TS 2162   B       126       95       16       VS2       -0.02   <TS 2163   B       126       99       19       08C       0.85   <TS 2164   B       126       99       14       07C       0.83   <TS 2165   B       126     103       17       VS4       0.85   <TS 2166   B       126     109       14       04H       0.87   <TS 2167   B       126     115         9       02C       0.11   <TS 2168   B       126     115       20       02C       0.83   <TS 2169   B       127       52       12       01H       -0.06   <TS 2170   B       127       54       19       01H       -0.83   <TS 2171   B       127       72       10       05H       0.89   <TS 2172   B       127       92       22       08C       -0.15   <TS 2173   B       127       92       11       VS6       -1.01   <TS 2174   B       127     102       13       07C       -0.15   <TS 2175   B       127     104       14       06C       0.85   <TS 2176   B       127     106       21       07C       -0.19   <TS 2177   B       127     108       13       06C       0.92   <TS 2178   B       127     110       16       02C       0.81   <TS 2179   B       127     112       20       02C       0.87   <TS 2180   B       127     112       13       04C       -1.02   <TS 2181   B       127     114       18       01H       -0.88   <TS 2182   B       127     114       13       02H       0.83   <TS 2183   B       127     114       12       02C       0.85   <TS 2184   B       127     114         8       03C       0.85   <TS 147 of 156
Percent No SG Row Column in Depth Location Elevation TS 2146 B
125 114 17 03C 0.85  
<TS 2147 B
125 116 17 02H 0.89  
<TS 2148 B
125 116 12 03H 0.83  
<TS 2149 B
125 116 18 VS4  
-0.87  
<TS 2150 B
125 116 7
VS4 0.89  
<TS 2151 B
125 118 13 05H  
-1.04  
<TS 2152 B
126 51 12 01C 0.83  
<TS 2153 B
126 55 17 02C 0.88  
<TS 2154 B
126 55 13 06H 0.92  
<TS 2155 B
126 61 15 VS1 0.88  
<TS 2156 B
126 81 11 VS4  
-0.86  
<TS 2157 B
126 83 17 VS1  
-0.18  
<TS 2158 B
126 91 8
VS4  
-0.86  
<TS 2159 B
126 91 21 VS2 0.04  
<TS 2160 B
126 95 19 VS6 1.05  
<TS 2161 B
126 95 25 VS4  
-0.9  
<TS 2162 B
126 95 16 VS2  
-0.02  
<TS 2163 B
126 99 19 08C 0.85  
<TS 2164 B
126 99 14 07C 0.83  
<TS 2165 B
126 103 17 VS4 0.85  
<TS 2166 B
126 109 14 04H 0.87  
<TS 2167 B
126 115 9
02C 0.11  
<TS 2168 B
126 115 20 02C 0.83  
<TS 2169 B
127 52 12 01H  
-0.06  
<TS 2170 B
127 54 19 01H  
-0.83  
<TS 2171 B
127 72 10 05H 0.89  
<TS 2172 B
127 92 22 08C  
-0.15  
<TS 2173 B
127 92 11 VS6  
-1.01  
<TS 2174 B
127 102 13 07C  
-0.15  
<TS 2175 B
127 104 14 06C 0.85  
<TS 2176 B
127 106 21 07C  
-0.19  
<TS 2177 B
127 108 13 06C 0.92  
<TS 2178 B
127 110 16 02C 0.81  
<TS 2179 B
127 112 20 02C 0.87  
<TS 2180 B
127 112 13 04C  
-1.02  
<TS 2181 B
127 114 18 01H  
-0.88  
<TS 2182 B
127 114 13 02H 0.83  
<TS 2183 B
127 114 12 02C 0.85  
<TS 2184 B
127 114 8
03C 0.85  
<TS 147 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation   TS 2185   B       128       53         16       01H       -0.11     <TS 2186   B       128       55         20       01C       -0.53     <TS 2187   B       128       57         12       01H       -0.86     <TS 2188   B       128       73         24       VS1       0.18     <TS 2189   B       128       73         14       VS4       0.88     <TS 2190   B       128       73         11       06H       0.02     <TS 2191   B       128       73         14       06H       0.94     <TS 2192   B       128       99         12       07C       0.85   .<TS 2193   B       128     101         23       05C       0.87     <TS 2194   B       128     109         14       02C       -0.11     <TS 2195   B       128     113         25       02C       -0.87     <TS 2196   B       129       56         21       01H       0.89     <TS 2197   B       129       56         19       01C       0.85     <TS 2198   B       129       58         11       01H       -0.84     <TS 2199   B       129       64         9       VS7       -0.83     <TS 2200   B       129       68         10       02H       -0.84     <TS 2201   B       129       84         18       06H       0.86     <TS 2202   B       129     102         22       08C       -0.97     <TS 2203   B       129     102         9       06C       -0.24     <TS 2204   B       129     102         13       08C       0.11     <TS 2205   B       129     104         15       07C       -0.2     <TS 2206   B       129     106         12       06C       0.82     <TS 2207   B       129     106         8       08C       -0.2     <TS 2208   B       129     106         20       08C       0.85     <TS 2209   B       129     108         6       06C       0.85     <TS 2210   B       129     108         11       02C       0.88     <TS 2211   B       129     110         17       02C       0.79     <TS 2212   B       130       55         19       01H       0.98     <TS 2213   B       130       55         19       02C       0.85     <TS 2214   B       130       65         15       VS4       0.61     <TS 2215   B       130       65         26       VS7         0.9     <TS 2216   B       130       65         10       VS2       -0.24     <TS 2217   B       130       69         12       05H       0.84     <TS 2218   B       130       79         10       VS2       -0.94     <TS 2219   B       130       91         22       DBC       1.31     <TS 2220   B       130     107         18       DBC       -1.75     <TS 2221   B       130     109         11       04H       0.85     <TS 2222   B       131       58         33       01C       0.83     <TS 2223   B       131       60         12       VS6       0.83     <TS 148 of 156
Percent No SG Row Column in Depth Location Elevation TS 2185 B
128 53 16 01H  
-0.11  
<TS 2186 B
128 55 20 01C  
-0.53  
<TS 2187 B
128 57 12 01H  
-0.86  
<TS 2188 B
128 73 24 VS1 0.18  
<TS 2189 B
128 73 14 VS4 0.88  
<TS 2190 B
128 73 11 06H 0.02  
<TS 2191 B
128 73 14 06H 0.94  
<TS 2192 B
128 99 12 07C 0.85  
.<TS 2193 B
128 101 23 05C 0.87  
<TS 2194 B
128 109 14 02C  
-0.11  
<TS 2195 B
128 113 25 02C  
-0.87  
<TS 2196 B
129 56 21 01H 0.89  
<TS 2197 B
129 56 19 01C 0.85  
<TS 2198 B
129 58 11 01H  
-0.84  
<TS 2199 B
129 64 9
VS7  
-0.83  
<TS 2200 B
129 68 10 02H  
-0.84  
<TS 2201 B
129 84 18 06H 0.86  
<TS 2202 B
129 102 22 08C  
-0.97  
<TS 2203 B
129 102 9
06C  
-0.24  
<TS 2204 B
129 102 13 08C 0.11  
<TS 2205 B
129 104 15 07C  
-0.2  
<TS 2206 B
129 106 12 06C 0.82  
<TS 2207 B
129 106 8
08C  
-0.2  
<TS 2208 B
129 106 20 08C 0.85  
<TS 2209 B
129 108 6
06C 0.85  
<TS 2210 B
129 108 11 02C 0.88  
<TS 2211 B
129 110 17 02C 0.79  
<TS 2212 B
130 55 19 01H 0.98  
<TS 2213 B
130 55 19 02C 0.85  
<TS 2214 B
130 65 15 VS4 0.61  
<TS 2215 B
130 65 26 VS7 0.9  
<TS 2216 B
130 65 10 VS2  
-0.24  
<TS 2217 B
130 69 12 05H 0.84  
<TS 2218 B
130 79 10 VS2  
-0.94  
<TS 2219 B
130 91 22 DBC 1.31  
<TS 2220 B
130 107 18 DBC  
-1.75  
<TS 2221 B
130 109 11 04H 0.85  
<TS 2222 B
131 58 33 01C 0.83  
<TS 2223 B
131 60 12 VS6 0.83  
<TS 148 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2224   B       131       64       23       VS7       0.99   <TS 2225   B       131       70       14       03C       0.85   <TS 2226   B       131       78       16       VS6       -0.88   <TS 2227   B       131       82       17       08H       -0.84   <TS 2228   B       131       88       13       07C       0.88   <TS 2229   B       131       96       12       08H       -0.11   <TS 2230   B       131       96       22       04C       0.86   <TS 2231   B       131     98         33       VS6       0.88   <TS 2232   B       131     98         31       VS7       0.72   <TS 2233   B       131     98         16       DBC       1.79   <TS 2234   B       131     100         9       06C       0.85   <TS 2235   B       131     102       21       06C       -0.96   <TS 2236   B       131     102       17       05C       0.83   <TS 2237   B       131     102       13       04C       0.89   <TS 2238   B       131     104       29       VS7       0.88   <TS 2239   B       131     104       15       DBC       1.68   <TS 2240   B       131     108       13       07H       -1.09   <TS 2241   B       132     61         12       01H       1.01   <TS 2242   B       132     75         11       02H       0.86   <TS 2243   B       132     81         12       05H       0.89   <TS 2244   B       132     91         14       DBC       1.32   <TS 2245   B       132     97         14       VS1       0.81   <TS 2246   B       132     97         22       VS2       -0.75   <TS 2247   B       132     97         8       VS2       -0.11   <TS 2248   B       132     97         15       VS4       -0.94   <TS 2249   B       132     97         6       VS4       0.53   <TS 2250   B       132     97         11       VS7       0.94   <TS 2251   B       132     101       15       VS7       0.79   <TS 2252   B       132     101       20       06C       0.85   <TS 2253   B       132     101       14       06C       -0.2   <TS 2254   B       132     103       16       VS7       -0.88   <TS 2255   B       132     103       12       DBC       -1.93   <TS 2256   B       132     107       26       02C       -0.9   <TS 2257   B       133     68         13       02H       0.88   <TS 2258   B       133     74         15       03H       0.86   <TS 2259   B       133     76         14       07C       0.85   <TS 2260   B       133     90         14       DBC       -1.93   <TS 2261   B       133     100       19       VS7       -0.15   <TS 2262   B       133     102       17       VS7       -0.83   <TS 149 of 156
Percent No SG Row Column in Depth Location Elevation TS 2224 B
131 64 23 VS7 0.99  
<TS 2225 B
131 70 14 03C 0.85  
<TS 2226 B
131 78 16 VS6  
-0.88  
<TS 2227 B
131 82 17 08H  
-0.84  
<TS 2228 B
131 88 13 07C 0.88  
<TS 2229 B
131 96 12 08H  
-0.11  
<TS 2230 B
131 96 22 04C 0.86  
<TS 2231 B
131 98 33 VS6 0.88  
<TS 2232 B
131 98 31 VS7 0.72  
<TS 2233 B
131 98 16 DBC 1.79  
<TS 2234 B
131 100 9
06C 0.85  
<TS 2235 B
131 102 21 06C  
-0.96  
<TS 2236 B
131 102 17 05C 0.83  
<TS 2237 B
131 102 13 04C 0.89  
<TS 2238 B
131 104 29 VS7 0.88  
<TS 2239 B
131 104 15 DBC 1.68  
<TS 2240 B
131 108 13 07H  
-1.09  
<TS 2241 B
132 61 12 01H 1.01  
<TS 2242 B
132 75 11 02H 0.86  
<TS 2243 B
132 81 12 05H 0.89  
<TS 2244 B
132 91 14 DBC 1.32  
<TS 2245 B
132 97 14 VS1 0.81  
<TS 2246 B
132 97 22 VS2  
-0.75  
<TS 2247 B
132 97 8
VS2  
-0.11  
<TS 2248 B
132 97 15 VS4  
-0.94  
<TS 2249 B
132 97 6
VS4 0.53  
<TS 2250 B
132 97 11 VS7 0.94  
<TS 2251 B
132 101 15 VS7 0.79  
<TS 2252 B
132 101 20 06C 0.85  
<TS 2253 B
132 101 14 06C  
-0.2  
<TS 2254 B
132 103 16 VS7  
-0.88  
<TS 2255 B
132 103 12 DBC  
-1.93  
<TS 2256 B
132 107 26 02C  
-0.9  
<TS 2257 B
133 68 13 02H 0.88  
<TS 2258 B
133 74 15 03H 0.86  
<TS 2259 B
133 76 14 07C 0.85  
<TS 2260 B
133 90 14 DBC  
-1.93  
<TS 2261 B
133 100 19 VS7  
-0.15  
<TS 2262 B
133 102 17 VS7  
-0.83  
<TS 149 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth Location Elevation TS 2263   B       133     102         20       07C       -1.01   <TS 2264   B       133     104         23       VS7         0.9   <TS 2265   B       133     104         12       VS7       -0.81   <TS 2266   B       133     104         15       DBC       1.89   <TS 2267   B       134       63         15       07C       0.83   <TS 2268   B       134       63         18       DBH       -1.68   <TS 2269   B       134       65         19       02H       0.86   <TS 2270   B       134       65         12       VS2       -0.72   <TS 2271   B       134       69         27       VS7       0.92   <TS 2272   B       134       69         17       04H       0.86   <TS 2273   B       134       95         21       DBC       1.72   <TS 2274   B       134       95         12       06C       0.83   <TS 2275   B       134       97         13       VS6       -0.87   <TS 2276   B       134       97         15       VS6       0.83   <TS 2277   B       134       99         12       VS4       -0.89   <TS 2278   B       134       99         15       VS6       -0.76   <TS 2279   B       134     99         26       VS6       0.98   <TS 2280   B       134     101         24       VS7       0.92   <TS 2281   B       135     68         13       02H       -0.96   <TS 2282   B       135     68         24       VS7       0.92   <TS 2283   B       135       72         21       VS7       -0.9   <TS 2284   B       135       76         22       VS7       -0.92   <TS 2285   B       135       76         16       08C       0.83   <TS 2286   B       135       76         19       08C       -0.96   <TS 2287   B       135     80         18       07H       -0.77   <TS 2288   B       135     82         22       VS7       -0.9   <TS 2289   B       135     82         23       VS7       0.95   <TS 2290   B       135     90         31       VS7         0.7   <TS 2291   B       135     92         37       VS7       -0.61   <TS 2292   B       135     92         33       08C       0.87   <TS 2293   B       135     92         25       07C       0.78   <TS 2294   B       135     94         26       DBC       1.75   <TS 2295   B       135     96         14       04C       0.83   <TS 2296   B       135     98         16       VS6       -0.8   <TS 2297   B       136     69         20       DBC         1.9   <TS 2298   B       136     77         18       03H       0.91   <TS 2299   B       136     87         15       08C       -1.01   <TS 2300   B       136     91         13       08C       -0.18   <TS 2301   B       136     91         23       DBC       1.88   <TS 150 of 156
Percent No SG Row Column in Depth Location Elevation TS 2263 B
133 102 20 07C  
-1.01  
<TS 2264 B
133 104 23 VS7 0.9  
<TS 2265 B
133 104 12 VS7  
-0.81  
<TS 2266 B
133 104 15 DBC 1.89  
<TS 2267 B
134 63 15 07C 0.83  
<TS 2268 B
134 63 18 DBH  
-1.68  
<TS 2269 B
134 65 19 02H 0.86  
<TS 2270 B
134 65 12 VS2  
-0.72  
<TS 2271 B
134 69 27 VS7 0.92  
<TS 2272 B
134 69 17 04H 0.86  
<TS 2273 B
134 95 21 DBC 1.72  
<TS 2274 B
134 95 12 06C 0.83  
<TS 2275 B
134 97 13 VS6  
-0.87  
<TS 2276 B
134 97 15 VS6 0.83  
<TS 2277 B
134 99 12 VS4  
-0.89  
<TS 2278 B
134 99 15 VS6  
-0.76  
<TS 2279 B
134 99 26 VS6 0.98  
<TS 2280 B
134 101 24 VS7 0.92  
<TS 2281 B
135 68 13 02H  
-0.96  
<TS 2282 B
135 68 24 VS7 0.92  
<TS 2283 B
135 72 21 VS7  
-0.9  
<TS 2284 B
135 76 22 VS7  
-0.92  
<TS 2285 B
135 76 16 08C 0.83  
<TS 2286 B
135 76 19 08C  
-0.96  
<TS 2287 B
135 80 18 07H  
-0.77  
<TS 2288 B
135 82 22 VS7  
-0.9  
<TS 2289 B
135 82 23 VS7 0.95  
<TS 2290 B
135 90 31 VS7 0.7  
<TS 2291 B
135 92 37 VS7  
-0.61  
<TS 2292 B
135 92 33 08C 0.87  
<TS 2293 B
135 92 25 07C 0.78  
<TS 2294 B
135 94 26 DBC 1.75  
<TS 2295 B
135 96 14 04C 0.83  
<TS 2296 B
135 98 16 VS6  
-0.8  
<TS 2297 B
136 69 20 DBC 1.9  
<TS 2298 B
136 77 18 03H 0.91  
<TS 2299 B
136 87 15 08C  
-1.01  
<TS 2300 B
136 91 13 08C  
-0.18  
<TS 2301 B
136 91 23 DBC 1.88  
<TS 150 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No   SG     Row   Column     in Depth   Location Elevation TS 2302   B       136       95       21       03C       0.88   <TS 2303   B       136       97       30       VS7       -0.79   <TS 2304   B       136       97       12       08C       0.11   <TS 2305   B       136       97       16       08C       -0.92   <TS 2306   B       136       97       13       07C       0.87   <TS 2307   B       136     97         19       03C       0.88   <TS 2308   B       136     97         15       VS7         0.9   <TS 2309   B       137       74       15       06H       0.81   <TS 2310   B       137       76       12       05H       0.84   <TS 2311   B       137       78       13       03H       -0.84   <TS 2312   B       137     80         19       08H       0.88   <TS 2313   B       137     90         23       DBH       1.75   <TS 2314   B       137     90         11       VS1       -0.81   <TS 2315   B       137     90         15       VS4       0.18   <TS 2316   B       137     90         11       VS4         0.7   <TS 2317   B       137     90         16       VS6       -0.66   <TS 2318   B       137     90         17       VS7       -0.88   <TS 2319   B       137     90         17       VS7       0.88   <TS 2320   B       137     90         18       DBC       1.97   <TS 2321   B       137     92         18       VS6       -0.85   <TS 2322   B       137     92         21       VS6       0.94   <TS 2323   B       137     92         23       VS7       -0.68   <TS 2324   B       137     92         15       08C       -1.03   <TS 2325   B       137     92         17       07C       0.07   <TS 2326   B       137     92         10       04C       0.83   <TS 2327   B       138     75         9       08H       -0.13   <TS 2328   B       138     77         20       02H       0.92   <TS 2329   B       138     77         13       03H       -0.92   <TS 2330   B       138     77         21       VS4       0.94   <TS 2331   B       138     79         15       03H       0.88   <TS 2332   B       138     79         23       VS1       -0.66   <TS 2333   B       138     79         23       VS2       0.79   <TS 2334   B       138     79         20       VS4       0.94   <TS 2335   B       138     79         19       VS6       -0.9   <TS 2336   B       138     79         20       VS6       0.96   <TS 2337   B       138     81         22       VS4       -0.88   <TS 2338   B       138     81         14       08C       -1.07   <TS 2339   B       138     85         14       08H       0.85   <TS 2340   B       138     85         27       DBH       1.79   <TS 151 of 156
Percent No SG Row Column in Depth Location Elevation TS 2302 B
136 95 21 03C 0.88  
<TS 2303 B
136 97 30 VS7  
-0.79  
<TS 2304 B
136 97 12 08C 0.11  
<TS 2305 B
136 97 16 08C  
-0.92  
<TS 2306 B
136 97 13 07C 0.87  
<TS 2307 B
136 97 19 03C 0.88  
<TS 2308 B
136 97 15 VS7 0.9  
<TS 2309 B
137 74 15 06H 0.81  
<TS 2310 B
137 76 12 05H 0.84  
<TS 2311 B
137 78 13 03H  
-0.84  
<TS 2312 B
137 80 19 08H 0.88  
<TS 2313 B
137 90 23 DBH 1.75  
<TS 2314 B
137 90 11 VS1  
-0.81  
<TS 2315 B
137 90 15 VS4 0.18  
<TS 2316 B
137 90 11 VS4 0.7  
<TS 2317 B
137 90 16 VS6  
-0.66  
<TS 2318 B
137 90 17 VS7  
-0.88  
<TS 2319 B
137 90 17 VS7 0.88  
<TS 2320 B
137 90 18 DBC 1.97  
<TS 2321 B
137 92 18 VS6  
-0.85  
<TS 2322 B
137 92 21 VS6 0.94  
<TS 2323 B
137 92 23 VS7  
-0.68  
<TS 2324 B
137 92 15 08C  
-1.03  
<TS 2325 B
137 92 17 07C 0.07  
<TS 2326 B
137 92 10 04C 0.83  
<TS 2327 B
138 75 9
08H  
-0.13  
<TS 2328 B
138 77 20 02H 0.92  
<TS 2329 B
138 77 13 03H  
-0.92  
<TS 2330 B
138 77 21 VS4 0.94  
<TS 2331 B
138 79 15 03H 0.88  
<TS 2332 B
138 79 23 VS1  
-0.66  
<TS 2333 B
138 79 23 VS2 0.79  
<TS 2334 B
138 79 20 VS4 0.94  
<TS 2335 B
138 79 19 VS6  
-0.9  
<TS 2336 B
138 79 20 VS6 0.96  
<TS 2337 B
138 81 22 VS4  
-0.88  
<TS 2338 B
138 81 14 08C  
-1.07  
<TS 2339 B
138 85 14 08H 0.85  
<TS 2340 B
138 85 27 DBH 1.79  
<TS 151 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)
Percent No     SG       Row       Column     in Depth   Location   Elevation     TS 2341     B       138         87         20         VS1         -0.81       <TS 2342     B       138         87         18         VS4         -0.79       <TS 2343     B       138         87         13         VS1         0.92       <TS 2344     B       138         89         19         VS4         -0.63       <TS 2345     B       138         89         12         VS6         0.85       <TS 2346     B       138         89         16         VS7         -0.79       <TS 2347     B       138         89         33         VS7         0.92       <TS 2348     B       138         89         14         07C         0.77       <TS 2349     B       138         89         12         VS6         -0.98       <TS 2350     B       138         91         18         DBH         1.97       <TS 2351     B       138         91         16         VS7         1.07       <TS Table 4D Wear Indication Summary Diagonal Bar Wear     Vertical Strap Wear I     Eggcrate Wear     [ Foreign Object Wear Tubes   Indications     Tubes   Indications   Tubes   Indications   Tubes   Indications SGA   175       184         473         787       1387       1949         3         3 SGB   131       137         515         842       1085       1372     1   2         3 152 of 156
Percent No SG Row Column in Depth Location Elevation TS 2341 B
138 87 20 VS1  
-0.81  
<TS 2342 B
138 87 18 VS4  
-0.79  
<TS 2343 B
138 87 13 VS1 0.92  
<TS 2344 B
138 89 19 VS4  
-0.63  
<TS 2345 B
138 89 12 VS6 0.85  
<TS 2346 B
138 89 16 VS7  
-0.79  
<TS 2347 B
138 89 33 VS7 0.92  
<TS 2348 B
138 89 14 07C 0.77  
<TS 2349 B
138 89 12 VS6  
-0.98  
<TS 2350 B
138 91 18 DBH 1.97  
<TS 2351 B
138 91 16 VS7 1.07  
<TS Table 4D Wear Indication Summary Diagonal Bar Wear Vertical Strap Wear I Eggcrate Wear
[ Foreign Object Wear Tubes Indications Tubes Indications Tubes Indications Tubes Indications SGA 175 184 473 787 1387 1949 3
3 SGB 131 137 515 842 1085 1372 1
2 3
152 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 5 Tube Plugging Summary by Damage Mechanism TUBE PLUGGING  
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 5 Tube Plugging Summary by Damage Mechanism TUBE PLUGGING  


==SUMMARY==
==SUMMARY==
SG E-50A       SG E-50B Wear- Vertical Straps                       0             1 Wear- Diagonal Bar                         0             0 Wear - Eggcrate                             0             0 Wear- Loose Part                           2             1 Wear- Dent                                 0             0 Wear - Tube to Tube (TBP)                   0             0 Wear - Volumetric                           0             0 Circumferential ODSCC TTS                   5             2 Axial ODSCC TTS                             1             2 Axial ODSCC Freespan Ding                   0             0 Axial ODSCC Eggcrate & Vertical Strap       1             3 Axial ODSCC in Greater Than 5 Volt Dents   0             0 Axial ODSCC in Less Than 5 Volt Dents       0             0 Axial PWSCC Tubesheet                       0             0 Circumferential PWSCC Tubesheet             0             0 Axial ODSCC in U-bend                       0             0 Restricted Tube                             0             0 Administrative                             4             1 2014 Outage Total                           13             10 Pre-service Tubes Plugged                   308           309 Effective Tubes Plugged                     537           446 Effective Tubes Plugged Percentage         6.5%           5.4%
SG E-50A SG E-50B Wear-Vertical Straps 0
SG Total Number of Tubes                   8219           8219 153 of 156
1 Wear-Diagonal Bar 0
0 Wear - Eggcrate 0
0 Wear-Loose Part 2
1 Wear-Dent 0
0 Wear - Tube to Tube (TBP) 0 0
Wear - Volumetric 0
0 Circumferential ODSCC TTS 5
2 Axial ODSCC TTS 1
2 Axial ODSCC Freespan Ding 0
0 Axial ODSCC Eggcrate & Vertical Strap 1
3 Axial ODSCC in Greater Than 5 Volt Dents 0
0 Axial ODSCC in Less Than 5 Volt Dents 0
0 Axial PWSCC Tubesheet 0
0 Circumferential PWSCC Tubesheet 0
0 Axial ODSCC in U-bend 0
0 Restricted Tube 0
0 Administrative 4
1 2014 Outage Total 13 10 Pre-service Tubes Plugged 308 309 Effective Tubes Plugged 537 446 Effective Tubes Plugged Percentage 6.5%
5.4%
SG Total Number of Tubes 8219 8219 153 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 6 Condition Monitoring Results Identification of Tubes Plugged (all conditions for tubes that were plugged in the 2014 refueling outage)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 6 Condition Monitoring Results Identification of Tubes Plugged (all conditions for tubes that were plugged in the 2014 refueling outage)
SG     Row Column           Location                 Reason For Plugging E-50A     23       118       01H-0.81                           SAI No Stabilization E-50A     24       49       TSH+0.17                           SCI Stabilization E-50A     33       52       TSH+0.38                           SAI No Stabilization E-50A     40       51       TSH-0.11                           SCl Stabilization E-50A     56       59       TSH-0.10                           SCI Stabilization E-50A     76       79       TSH+0.11                           SCI Stabilization E-50A     105       104       TSH+0.01                           SCI Stabilization E-50A     132       73       ADMIN                             PTP Stabilization E-50A     133       74       TSH+0.01                           SVI Stabilization E-50A     134       73       ADMIN                             PTP Stabilization E-50A     134       75       TSH+0.00                           SVI Stabilization E-50A     135       74         ADMIN                             PTP Stabilization E-50A     136       75         ADMIN                             PTP Stabilization E-50B       3       112       ADMIN                             PTP No Stabilization E-50B     23       46       TSH+0.42                           SAI No Stabilization E-50B     23       110       01H-0.23                           SAI No Stabilization E-50B     28       51       TSH+0.1 1                         SCI Stabilization E-50B     29       106       01H-0.28                           SAI No Stabilization E-50B     74       75       TSH-0.09                           SCI Stabilization E-50B     76       95       TSH+1.40                           SAI No Stabilization E-50B     82       115       01H-0.97                           SAI No Stabilization E-50B     108       35       TSC+0.00                           SVI Stabilization E-50B     113       48       VS2-0.91                       WAR (41%)
SG Row Column Location Reason For Plugging E-50A 23 118 01H-0.81 SAI No Stabilization E-50A 24 49 TSH+0.17 SCI Stabilization E-50A 33 52 TSH+0.38 SAI No Stabilization E-50A 40 51 TSH-0.11 SCl Stabilization E-50A 56 59 TSH-0.10 SCI Stabilization E-50A 76 79 TSH+0.11 SCI Stabilization E-50A 105 104 TSH+0.01 SCI Stabilization E-50A 132 73 ADMIN PTP Stabilization E-50A 133 74 TSH+0.01 SVI Stabilization E-50A 134 73 ADMIN PTP Stabilization E-50A 134 75 TSH+0.00 SVI Stabilization E-50A 135 74 ADMIN PTP Stabilization E-50A 136 75 ADMIN PTP Stabilization E-50B 3
I_                 I             I                 No Stabilization 154 of 156
112 ADMIN PTP No Stabilization E-50B 23 46 TSH+0.42 SAI No Stabilization E-50B 23 110 01H-0.23 SAI No Stabilization E-50B 28 51 TSH+0.1 1 SCI Stabilization E-50B 29 106 01H-0.28 SAI No Stabilization E-50B 74 75 TSH-0.09 SCI Stabilization E-50B 76 95 TSH+1.40 SAI No Stabilization E-50B 82 115 01H-0.97 SAI No Stabilization E-50B 108 35 TSC+0.00 SVI Stabilization E-50B 113 48 VS2-0.91 WAR (41%)
I_
I I
No Stabilization 154 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7A Steam Generator Support Structure Nomenclature Name           Description           Name           Description TEH   Tube End - Hot Side             VS4 Fourth Vertical Strap TSH   Top of Tubesheet - Hot Side     VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side       VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side       VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side       DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side       08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side       07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side       06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side     05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side       04C Fourth Eggcrate - Cold Side DBH   Diagonal Strap - Hot Side       03C Third Eggcrate - Cold Side VS1   First Vertical Strap             02C Second Eggcrate - Cold Side VS2   Second Vertical Strap           01C First Eggcrate - Cold Side VS3   Third Vertical Strap             TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side 155 of 156
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7A Steam Generator Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side 05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side 155 of 156


Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7B Acronyms and Abbreviations Acronym       Definition AVB         Anti Vibration Bar BED           Burst Equivalent Depth BEL           Burst Equivalent Length CMOA         Condition Monitoring and Operational Assessment DDI           Dent or Ding with Indication DSI           Distorted Support Indication ETSS         Examination Technique Specification Sheet FDMS         AREVA Data Management System LP           Loose Part MRPC         Motorized Rotating Pancake Coil (+Pt. TM)
Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7B Acronyms and Abbreviations Acronym Definition AVB Anti Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DDI Dent or Ding with Indication DSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AREVA Data Management System LP Loose Part MRPC Motorized Rotating Pancake Coil (+Pt. TM)
MBM           Manufacturing Burnish Mark NDD           No Degradation Detected NDE           Non Destructive Examination NQI           Non-Quantifiable Indication NTE           No Tube Expansion ODSCC         Outside Diameter Stress Corrosion Cracking PDA           Percent Degraded Area PLG         Tube Is Plugged PLP           Possible Loose Part PTE           Partial Tube Expansion PTP           Preventative Tube Plug PVN           Permeability Variation PWSCC         Primary Water Stress Corrosion Cracking SAI         Single Axial Indication SCI           Single Circumferential Indication SVI         Single Volumetric Indication TBP         To Be Plugged TSP         Tube Support Plate TTS         Top of Tubesheet TW           Through Wall
MBM Manufacturing Burnish Mark NDD No Degradation Detected NDE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWSCC Primary Water Stress Corrosion Cracking SAI Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication TBP To Be Plugged TSP Tube Support Plate TTS Top of Tubesheet TW Through Wall
    <TS           Less Than Technical Specification WAR         Wear Indication 156 of 156}}
<TS Less Than Technical Specification WAR Wear Indication 156 of 156}}

Latest revision as of 13:56, 10 January 2025

2014 Refueling Outage Steam Generator Inspection Report - Response to Request for Additional Information
ML15068A352
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/04/2015
From: Hardy J
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PNP 2015-010
Download: ML15068A352 (165)


Text

Entergy Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530 Tel 269 764 2000 Jeffery A. Hardy Regulatory Assurance Manager PNP 2015-010 March 04, 2015 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Response to Request for Additional Information - Palisades Nuclear Plant 2014 Refueling Outage Steam Generator Inspection Report Palisades Nuclear Plant Docket 50-255 License No. DPR-20

References:

1. ENO letter to NRC, PNP 2014-072, "2014 Steam Generator Tube Inspection Report," dated August 5, 2014 (ADAMS Accession Number ML14218A548)
2. NRC e-mail to ENO, "Request for Additional Information - Palisades Nuclear Plant 2014 Steam Generator Tube Inspection Report -

MF4569," dated December 16, 2014 (ADAMS Accession Number ML14350B371)

Dear Sir or Madam:

Entergy Nuclear Operations, Inc. (ENO) submitted Reference 1 to the Nuclear Regulatory Commission (NRC) providing the results of steam generator tube inspections conducted during the 2014 Palisades Nuclear Plant (PNP) refueling outage.

ENO received an electronic request for additional information (RAI) from the NRC in Reference 2. ENO and the NRC held a conference call on December 16, 2014 to clarify the RAI.

Attached is the ENO response to the RAI.

This letter contains no new or revised commitments.

Sincerely, jah/jpm

PNP 2015-010 Page 2 of 2 : Response to "Request for Additional Information Regarding the January-February 2014 Steam Generator Tube Inspections" : Errata Information, "Replacement Information for the Palisades Nuclear Plant Steam Generator Tube Inspection Report for the 2014 Refueling Outage, 1 R23" cc:

Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC

ATTACHMENT 1 RESPONSE TO "REQUEST FOR ADDITIONAL INFORMATION REGARDING THE JANUARY-FEBRUARY 2014 STEAM GENERATOR TUBE INSPECTIONS" A request for additional information (RAI) regarding the January-February 2014 Steam Generator Tube Inspections Palisades Nuclear Plant Docket No. 50-255 was received by electronic mail on December 16, 2014.

By letter dated August 5, 2014 (Agency wide Documents Access and Management System (ADAMS) Accession No. ML14218A548), Entergy Nuclear Operations, Inc. (the licensee) submitted information summarizing the results of the 2014 steam generator tube inspections performed at Palisades Nuclear Plant. These inspections were performed during refueling outage 23 in January-February, 2014. In a letter dated April 30, 2014 (ADAMS Accession No. ML14093A243), the U.S. Nuclear Regulatory Commission (NRC) staff summarized a conference call with the licensee regarding the January-February 2014 steam generator tube inspections. The NRC staff reviewed the information provided and determined that additional information is required in order to complete its review.

Nuclear Regulatory Commission (NRC) Request

1. There are several instances in the report where it does not appear the results were properly communicated and/or the technical details were not fully understood. Please clarify the following:
a. Item "g" on page 3 of 156 indicates, in part, that the results of the condition monitoring are provided in Table 6. Table 6 does not have the indicated information; however, it appears the results are provided further down on the page.

ENO Response

a. Items "a" through "h" listed in page 3 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" are quoted from Palisades Technical Specification Section 5.6.8, "Steam Generator Tube Inspection Report," with the addition of report table references in parenthesis. Entergy Nuclear Operations, Inc. (ENO) revised Item "g" to clarify that table 6 includes the as found condition of tubes that were plugged and that the remaining condition monitoring results are provided in the body of the report. The revised wording is provided below and in Attachment 2 to this RAI response.

Page 1 of 6

"g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6-as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below),

and" NRC Request In addition, on page 3 of 156 there is a discussion about the accident induced leakage performance criteria. The following statements were made:

Leakage did not exceed the 0.3 gallon per minute (gpm) accident induced leakage limit. Primary-to-secondary leak rate measured using condenser off-gas (Xenon-135) was measured at 0.0003 gpm for the start of operating cycle 23, finished at <0.0001 gpm and had a decreasing trend over the cycle.

No leakage was predicted for either operating or accident conditions for the 2012 to 2014 operating cycle due to observed SG tube degradation in the 2014 refueling outage. All plugs installed were Alloy 690 in the Palisades SGs post-operation and are either Westinghouse ribbed mechanical plugs or Areva mechanically rolled plugs. The Westinghouse plugs are leak-tight for all plant conditions.

The Areva roll expansion provides a leak-limiting seal between the plug and tube wall.

Accident induced leakage is the primary-to-secondary leakage that occurs during a design basis accident. As a result, this value is calculated based, in part, on inspection results. Other sources of accident induced primary-to-secondary leakage are leakage past plugs and other repairs. In addition, implementation of alternate repair criteria may also be a source of accident induced leakage particularly when the criteria eliminates the need to inspect certain locations of the tube.

1)

Therefore, please clarify whether or not the first sentence in the above quote was intended to indicate that the calculated leakage from all potential sources of accident induced leakage did not exceed the 0.3 gpm accident induced leakage limit.

2)

Please confirm that the second sentence in the above quote was simply a statement regarding operational leakage.

3)

Please clarify that the third sentence in the above quote only includes the contribution to the accident induced leakage associated with the observed degradation mechanisms.

Page 2 of 6

4)

Please confirm that the accident induced leakage associated with the Areva roll expanded plugs (i.e., leak limiting plugs) was combined with the accident induced leakage associated with implementation of the C* alternate repair criteria and the accident induced leakage from all other sources (presumably zero for the observed degradation mechanisms based on the third sentence in the above quote) for comparison against the 0.3 gpm accident induced leakage limit.

ENO Response

1)

Yes, the first sentence was intended, in summary, to indicate that leakage from all potential sources was included in the calculation of accident induced leakage and the resultant value did not exceed the 0.3 gpm accident induced leakage limit.

2)

Yes, the second sentence is a statement of operational leakage over the 2012 to 2014 operating cycle.

3)

Yes, the third sentence was intended to state the accident induced leakage contribution associated with the 2014 refueling outage inspection's observed steam generator (SG) tube degradation mechanisms only.

4)

Yes, the accident induced leakage calculation did include predicted leakage from Areva roll expanded plugs (i.e., leak limiting plugs),

implementation of C* alternative repair criteria, and all other potential sources for comparison against the 0.3 gpm accident induced leakage limit.

NRC Request

b.

Please clarify that Tables 4A, 4B, and 4C provide all of the service induced indications. If not, please provide any service induced indications not included in those tables (e.g., the wear indications associated with possible loose parts). Please ensure the location, orientation (if linear), and measured sizes (if available) of all service induced indications are provided (since it does not appear that such information was provided for some of the indications such as wear associated with possible loose parts). The staff notes that the statements that "Table 4A provides the location and measured sizes of service induced indications" and the majority "are a result of axial and circumferential outside diameter stress corrosion cracking" indications is misleading since Table 4A only provides a subset of service induced indications and only includes axial and circumferential outside diameter stress corrosion cracking indications.

Page 3 of 6

ENO Response

b.

Additional information was added to Table 4A to include volumetric indications with loose parts present. Page 4 and 16 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised. The revised wording is provided below and in Attachment 2 of this RAI response.

Page 4, "Service Induced Indications,"

There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes were affected by this part.

Page 16, "Table 4A,"

Volumetric Indications with Loose Part Present NDE Sizing Maximum Circumferential NDE Axial SG Row Col.

Location ETSS

(%Dp)

Length (deg.)

Length (in.)

(Note 1)

SG TSH A

133 74 400 27901.1 37 58 0.33 A

+0.0i SG TSH A

134 75

+00 27901.1 51 70 0.30 A

+0.00 SG I rT SC t111 B

108 35

+0.00 10908.4 11 54 0.23 Nuclear Regulatory Commission (NRC) Request

c.

Please confirm that the tubes in SG A row 134, column 75 and SG A row 133, column 74 had wear attributed to a loose part since the last sentence indicates that "these tubes had no wear indications from the loose part." It was not clear which tubes were being referred to by the reference to "these tubes."

ENO Response

c.

Page 4 of "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised to clarify that "these tubes" is referring to SG A Row 134 Column 75 and SG A Row 133 Column 74. The revised wording is provided below and in to this RAI response.

Page 4 of 6

"There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future."

NRC Request

d.

The headings for the tables on pages 152 through 156 reference the 2012 refueling outage. Please clarify.

ENO Response

d.

The headings for the tables on pages 153 through 156 have been revised in "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" to reference 2014 rather than 2012. The revised wording is provided in Attachment 2 to this RAI response.

Note that due to other document revisions and formatting the above referenced page numbers have been revised to pages 153 through 156.

NRC Request

2. Please discuss the nature of the restriction in the tube in row 3, column 112 in steam generator E-50B. For example, has the condition changed with time?

ENO Response

2.

Page 4 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised better describe the nature of the restriction in row 3, column 112. The revised wording is provided below and in Attachment 2 to this RAI response.

"Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of Page 5 of 6

SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1 R21, 1 R22, and 1 R23 inspections."

NRC Request

3. Please summarize the number of indications of wear detected and how many tubes are affected (e.g., 10 indications of wear at the eggcrate supports in 8 tubes, 35 indications of wear at the diagonal bars in 22 tubes, etc.).

ENO Response

3. Table 4D "Wear Indication Summary" was added to page 152 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23". The new table is provided below and in to this RAI response.

Table 4D Wear Indication Summary Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear Foreign Object Wear Tubes Indications Tubes Indications Tubes Indications Tubes Indications SGA 175 184 473 787 1387 1949 3

3 SGB 131 137 515 842 1085 1372 2

3 NRC Request

4. Please discuss whether an inspection of the plugs was performed. If so, please discuss the results of the inspection (e.g., all plugs were present in the proper location and no degradation was observed).

ENO Response

4.

Page 4 paragraph 1 of the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1 R23" was revised discuss the visual inspection that was performed on the tube plugs. The revised wording is provided below and in Attachment 2 to this RAI response.

"A 100% visual inspection of the previously installed plugs was performed with no anomalies identified. Plug location was also verified."

Page 6 of 6

ATTACHMENT 2 ERRATA INFORMATION REPLACEMENT INFORMATION FOR THE PALSAIDES NUCLEAR PLANT STEAM GENERATOR TUBE INSPECTION REPORT FOR THE 2014 REFUELING OUTAGE, 1R23 Replace this report in its entirety due to content and format changes.

Content changes were made on the following pages as indicated below:

Report Pages: 2, 3, 4, 5, 17, 152, 153, 154, 155, and 156 Report Tables: 4A and 4D Changes to the information submitted in the "Palisades Nuclear Plant Steam Generator Tube inspection Report for the 2014 Refueling Outage, 1R23" are indicated by vertical lines in the right hand column.

156 Pages Follow

Steam Generator Tube Inspection Report for the 2014 Refueling Outage PALISADES NUCLEAR PLANT STEAM GENERATOR TUBE INSPECTION REPORT for the 2014 REFUELING OUTAGE, 1R23 EC 54968 1 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage TABLE OF CONTENTS Inspection Summary 3

Table A Refueling Outage (RFO) Information since Steam Generator Replacement 6

Table 1 Scope and Extent of Tubes Inspected 7

Table 2 Active Damage Mechanisms 7

Table 3 Eddy Current Techniques 8

Table 4A Location and Measured Sizes of Service Induced Indications 14 Table 4B Steam Generator E-50A Indications 17 Table 4C Steam Generator E-50B Indications 92 Table 4D Wear Indication Summary 152 Table 5 Tube Plugging Summary by Damage Mechanism 153 Table 6 Condition Monitoring Results Identification of Tubes Plugged 154 Table 7A Steam Generator Support Structure Nomenclature 155 Table 7B Acronyms and Abbreviations 156 2 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Inspection Summary Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports, requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report shall include:

a. The scope of inspections performed on each SG (Table 1),
b. Active degradation mechanisms found (Table 2),
c. Nondestructive examination techniques utilized for each degradation mechanism (Table 3),
d. Location, orientation (if linear), and measured sizes (if available) of service induced indications (Tables 4A, 4B and 4C),
e. Number of tubes plugged during the inspection outage for each active degradation mechanism (Table 5),
f. Total number and percentage of tubes plugged to date (Table 5),
g. The results of condition monitoring, including the results of tube pulls and in-situ testing, (Table 6-as found condition; structural integrity, accident induced leakage, in-situ testing, and tube pulls provided below), and
h. The effective tube plugging percentage for all plugging in each SG (Table 5).

ENO performed an inspection of its two Combustion Engineering (CE) SGs in January-February 2014 during refueling outage 1R23. This inspection was the 1 5 th in-service inspection (ISI) following SG installation in 1990 and the 2 nd of 4 scheduled inspections in the 4th sequential inspection period. The unit initially entered mode 4 following this inspection on March 13, 2014.

The TS section 5.5.8b.1 steam generator tube integrity structural integrity performance criterion was satisfied. The TS section 5.5.8b.2 steam generator tube integrity accident induced leakage performance criterion was satisfied.

Leakage did not exceed the 0.3 gallon per minute (gpm) accident induced leakage limit. Primary-to-secondary leak rate measured using condenser off-gas (Xenon-1 35) was measured at 0.0003 gpm for the start of operating cycle 23, finished at < 0.0001 gpm and had a decreasing trend over the cycle.

No leakage was predicted for either operating or accident conditions for the 2012 to 2014 operating cycle due to observed SG tube degradation in the 2014 refueling outage. All plugs installed were Alloy 690 in the Palisades SGs post-operation and are either Westinghouse ribbed mechanical plugs or Areva mechanically rolled plugs. The Westinghouse plugs are leak-tight for all plant conditions. The Areva roll expansion provides a leak-limiting seal between the plug and tube wall.

3 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage The Palisades SGs also contain 308 tubes plugged pre-service in SG E-50A, and 309 tubes plugged pre-service in SG E-50B. Of the tubes plugged pre-service, one tube in SG E-50A and four tubes in SG E-50B are plugged using welded plugs, which are leak tight. The remaining tubes plugged pre-service are plugged using CE Alloy 690 roll plugs. There have been no reported industry events related to corrosion degradation of these Alloy 690 plugs. A 100% visual inspection of the previously installed plugs was performed with no anomalies identified. Plug location was also verified.

Thirteen tubes were plugged in SG E-50A and ten tubes in SG E-50B during the 2014 refueling outage.. Refer to Tables 5 and 6 for details.

There were no new damage mechanisms identified in the steam generator eddy current inspection in 2014.

Service Induced Indications Table 4A provides the location and measured sizes of service induced indications. The majority of these indications are a result of tube indications from axial and circumferential outside diameter stress corrosion cracking (ODSCC).

The remaining indications were from tube wear by support structures.

There was one loose part location in SG A which caused wear. SG A Row 134 Column 75 and SG A Row 133 Column 74 have single volumetric indication (SVI). SG A Row 134 Column 75 and SG A Row 133 Column 74 along with four adjoining tubes, Row 132 Column 73, Row 134 Column 73, Row 135 Column 74, and Row 136 Column 75 were plugged and stabilized as a result. The part was not able to be removed. SG A Row 132 Column 73, SG A Row 134 Column 73, SG A Row 135 Column 74, and SG A Row 136 Column 75 had no wear indications from the loose part but were stabilized and removed from service by tube plugging to prevent issues due to wear from the loose part in the future.

There was one loose part location in SG B which caused wear. SG B Row 108 Column 35 has a single volumetric indication (SVI). The part was not able to be removed. No other inservice tubes are affected by this part.

Tube Row 3 Column 112 in SG E-50B was preventatively plugged due to being restrictive and difficult to acquire eddy current data. Similar difficulties acquiring data in this location has been observed during previous inspections. There has been no significant change in the degree of difficulty in data acquisition however to preclude repeating the same difficulties during future inspections the subject tube was preventively plugged. Additionally, eddy current data was acquired over the full length of SG B Row 3 Column 112 tube with No Degradation Detected (NDD) during 1 R21, 1 R22, and 1 R23 inspections.

4 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Tables 4B & 4C provide listings of service induced indications with their location, orientation (if linear), and measured sizes. These two tables list all the wear indications for SG E-50A and SG E-50B identified in eddy current testing including those removed from service by tube plugging.

Tube Plugging Summary Table 5 provides a summary of the tubes plugged during 1 R23 for each active degradation mechanism in each steam generator. This table also includes the total number and percentage of tubes plugged to date along with the effective percentage for all plugging in each SG. No repairs other than plugging (e.g.

sleeving) have been performed in the Palisades SGs so the effective plugging is equal to the total plugging. Table 6 provides a list of the individual tubes plugged during 1 R23.

Tube Pulls and In-Situ Pressure Testing No tubes were pulled in either SG. No tubes required in-situ pressure testing per eddy current inspection results in the 2014 refueling outage.

5 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table A Refueling Outage (RFO) Information since Steam Generator Replacement First Second Third Fourth Outage Cycle Cumulative Inspection Inspection Inspection Inspection Outage Year EFPD EFPY Period Period Period Period (EFPMs)

(EFPMs)

(EFPMs)

(EFPMs) 1 R9 1992 298.5 0.82 9.84 1R10 1993 356.8 1.79 11.72 1R11 1995 430.5 2.97 25.87 1R12 1996 407.4 4.09 39.25 1R13 1998 419.6 5.24 53.04 1R14 1999 449.3 6.47 7.80 1R15 2001 401.3 7.57 20.98 1R16 2003 444.3 8.78 35.58 1R17 2004 493.1 10.13 51.78 1R18 2006 487.9 11.47 7.81 1R19 2007 459.3 12.73 22.90 1R20 2009 499.8 14.09 39.32 1R21 2010 507.7 15.48 56.00 1R22 2012 504.0 16.84 12.54 1R23 2014 513.3 18.25 29.14 EFPD = effective full power days EFPM = effective full power months EFPY = effective full power years 6 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 1 Scope and Extent of Tubes Inspected Scope Probe Type SG E-50A SG E-50B Full LengthO Bobbin 100%

100%

Row 1 through 3 U-bends MRPC 100%

100%

Hot Leg Tubesheets TTS+3"/-1 3.5" MRPC 100%

100%

Cold Leg Outer Three Periphery Tubes TTS+3"/-2" for detection of MRPC 12.0%

12.1%

possible loose parts or wear signals Freespan Dings > 5.0 Volts between MRPC 100%

100%

TSH and TSC in both SGs Vertical Strap, Diagonal Bar Dents &

MRPC 100%

100%

Eggcrate Dents > 2.0 Volts Historical Wear at Eggcrates MRPC 100%

100%

Historical Wear at Diagonal Bars MRPC 25%

25%

and Vertical Straps SupplementalO MRPC 100%

100%

Plug Visual N/A 100%

100%

D Except the bend portion of rows 1 through 3 0 All DDI, DSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications.

Table 2 Active Damage Mechanisms SG Location Damage Mechanism E-50A&B Diagonal bar (DB) support wear Wear E-50A&B Vertical strap (VS) support wear Wear E-50A&B Eggcrate (EC) support wear Wear E-50A&B Foreign object (FO) wear Wear Axial outer diameter stress corrosion E-50A&B cracking (ODSCC) at hot leg EC Axial ODSCC intersections E-50A&B Axial ODSCC at hot leg top-of-tubesheet Axial ODSCC (TTS) locations E-5OA&B Circumferential ODSCC at hot leg top-of-Circumferential ODSCC tubesheet (TTS) locations Nondestructive Examination Techniques Beginning on the next page, Table 3 lists the nondestructive examination techniques utilized for each degradation mechanism.

7 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation P

T Demonstrated Extended Mechanism PbTe_

[Applicability Applicability Detection Sizing BOBBIN Tube to Tube 13091.1 Freespan tube-Bobbin to-tube wear None Yes CMOA Wear Rev. 0at10kz_____

at 190 kHz Freespan (excluding u-128413 bend), eggcrate, Axial ODSCC Bobbin Rev. 3 sludge pile, &

None Yes No broached TSPs with or without dents <2Vpp 24013.1 Freespan Axial ODSCC Bobbin Rev. 2 including dings None Yes No R 25v Foreign object wear Extended for Fo r

Bobbin 27091.2 (part not 1-600 tubing Yes CMOA Frei r Rev. 1 present); 1-690 tubing 96004.1 AVBs, TSPs, Support Wear Bobbin Rev. 13 vertical and None Yes CMOA diagonal straps 8 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 EdvCurrntDemonstate Plsde 1xt23e Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability 96005.2 Freespan in the Pitting Bobbin Rev. 9 presence of Sludge Pile Yes CMOA copper Axial ODSCC 128424 Rev. 3 TSP (with or BED:

without dents CMOA Axial ODSCC

+PointTM (ect; whotdnsNone Yes CO 128431

<=2vpp) and Rev. 2 sludge pile BEL: CMOA (sizing) 128425 Freespan Rev. 3 (excluding u-BED:

(detect) bend), eggcrate, CMOA Axial ODSCC

+PointTM

& broached None Yes 128432 TSPs with or BEL: CMOA Rev.2 without dents (sizing)

<2Vpp Axial ODSCC

+Point TM 10411.1 Low Row U-Higher Row Yes CMOA Rev. 0 bends U-bends 9 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1 R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Support PDA:

structures, Information Axial ODSCC

+Point TM 21409.1

freespan, U-bends Yes Rev. 7 sludge pile, &

tubesheet Length:

crevice Information Depth:

22401.1 Freespan Information Axial ODSCC

+PointTM Rev. 4 Dented TSPs dings &

Yes dented AVBs Length:

CMOA PDA:

Expansion Tubesheet &

Information Axial PWSCC

+PointTM 20511.1 pansion non-dented Yes Rev. 8 Transitions spot egh supports Length:

CMOA Depth:

96703.1 Tubesheet &

CMOA Axial PWSCC

+PointM 960.1 Dents non-dented Yes Rev. 17 supports Length:

CMOA Axial PWSCC

+Point TM 96511.2 Low Row U-Higher Row Yes CMOA Rev. 16 bends U-bends Axial PWSCC

+Point TM 99997.2 Low Row U-Higher Row Yes CMOA Rev. 10 bends U-bends 10 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Circ ODSCC Depth:

Information Circ ODSCC

+Point TM 21410.1 Expansion None Yes PDA:

Rev. 6 Transitions CMOA Length:

CMOA Circ ODSCC

+Point TM 22842.1 Dented Freespan Yes CMOA Rev. 4 Supports dings EPRI PDA:

EPI Expansion NnSing CMOA Circ ODSCC

+Point TM TR-1 07197-Transitions None Sizing Depth:

P1 CMOA Circ PWSCC Circ PWSCC

+PointTM 111524 Expansion None Yes No Rev. 0 Transitions Circ PWSCC

+PointTM 20510.1 Expansion U-bends Yes CMOA Rev. 7 Transitions S96511.2 Low Row U-Higher Row For Circ PWSCC

+PointTM 16 Low R U

H er o

Yes information Rev. 16 bends U-bends olonly Circ PWSCC

+PointTM 96701.1 Expansion Dents and Yes CMOA Rev. 12 Transitions tubesheet 11 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 Eddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Detection Sizing Mechanism Applicability Applicability Detection Sizing S99997.2 Low Row U-Higher Row For Circ PWSCC

+PointTM Rev. 10 Row U Hier o Yes information Rev. 10 bends U-bends ol only Wear Pitting tTM 21998.1 Volumetric in Pitting

+Poin Rev. 4 freespan Sludge Pile Yes CMOA Specialty Probes Both:

CMOA 20407.1 Support Axial ODSCC Ghent**

Rev. 7 structures &

None Yes Avg. Depth/

freespan Length applies to technique 12 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 3 ddy Current Technique Palisades 1R23 Degradation Probe Type EPRI ETSS Demonstrated Extended Mechanism Probe Applicability Applicability Detection Sizing CMOA Axial PWSCC Ghent**

20508.1 Expansion None Yes Length Rev. 6 Transitions applies to technique Axial PWSCC Ghent**

20509.1 Dented support None Yes Not Rev. 5 structures qualified CMOA Top of Circ ODSCC Ghent**

20406.1 tubesheet &

None Yes Depth/

Rev. 7 expansion Length/

transitions PDA apply to technique Circ PWSCC Ghent**

20507.1 Expansion None Yes CMOA Rev. 6 Transitions

  • There are multiple ETSSs available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used. If foreign object wear (with no part present) is reported, an appropriate +Point TM or pancake coil technique will be selected for performing CMOA. The associated NDE uncertainties and CMOA limits will be documented in the CMOA report.
    • The Ghent probe will only be used if needed for clarification of the eddy current response or for additional sizing information associated with unusual or unexpected indications.

13 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Axial ODSCC Indications

+Point 300 NDE Maximum Structural kHz NDEEMaximumSStructura SG Row Col.

Location

+on Depth (%TW)

NDE Axial Structural Depth (%TW)

Amplitude (Note 1)

Length (in.)

Length (in.)

(Note 1)

(Vpp)

1)

(Note_1)

SGA 23 118 01H -0.81 0.30 42.81 0.27 SGA 33 52 TSH +0.35 0.225*

42.21 0.24 0.19 35.3 SGA 33 52 TSH +0.63 0.73*

61.69 0.28 0.19 53.9 SGB 23 46 TSH +0.43 0.615*

58.85 0.20 0.14 52.0 SGB 23 110 01H -0.23 0.27 40.61 0.96 SGB 29 106 01H -0.28 0.35*

46.03 1.51 0.6 41.0 SGB 76 95 TSH +1.40 0.41 52.14 0.39 SGB 82 115 01H -0.97 0.38 47.75 0.14 Note 1) The NDE maximum depth values were calculated using the Appendix I regression techniques (%TW as function of NDE voltage) and then reduced by 11 %TW as identified in the Entergy Appendix I deviation. Both the NDE Maximum Depth and Structural Depth values, shown in this table, reflect the 11 %TW reduction.

  • The average voltage (average of lead-in and lead-out) was used for the indications that received line by line sizing; hence, these voltages are not be found in FDMS and can result in three digits.

14 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Circumferential ODSCC Indications NDE Percent

+Point 300 kHz Degraded Area Circumferential Amplitude (Vpp)

(PDA)

Length (deg.)

(Note 1)

SGA 24 49 TSH +0.24 0.43 4.90 54 SGA 40 51 TSH +0.12 0.39 6.38 101 SGA 40 51 TSH -0.08 0.30 4.90 50 SGA 56 59 TSH -0.15 0.30 9.33 77 SGA 76 79 TSH +0.13 0.29 9.38 70 SGA 105 104 TSH -0.03 0.25 2.92 54 SGB 28 51 TSH +0.07 0.40 11.7 77 SGB 74 75 TSH -0.05 0.35 2.2 50 Note 1) All Circumferential indications were sized using the EPRI Draw Program which measured depths circumferentially from which a Percent Degraded Area (PDA) was calculated.

15 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4A Location and Measured Sizes of Service Induced Indications Volumetric Indications with Loose Part Present Sizing Circumferential NDE Axial SG Row Col.

Location ETSS Depth (%TW)

Length (deg.)

Length (in.)

(Note 1)

SGA 133 74 TSH +0.01 27901.1 37 58 0.33 SGA 134 75 TSH +0.00 27901.1 51 70 0.30 SGB 1 108 35 TSC+0.00 10908.4 11 54 0.23 16 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1

A 1

2 12 04C

-1.04

<TS 2

A 1

2 9

02H 0.87

<TS 3

A 1

128 11 02C 0.92

<TS 4

A 1

136 13 02H

-0.95

<TS 5

A 1

140 6

DBH

-0.99

<TS 6

A 1

150 18 02C 0.87

<TS 7

A 1

150 12 01C

-0.15

<TS 8

A 1

162 10 01C 0.88

<TS 9

A 2

7 9

02H 0.76

<TS 10 A

2 9

11 02C

-0.98

<TS 11 A

2 31 11 03H 0.85

<TS 12 A

2 127 19 05C 0.44

<TS 13 A

2 127 10 DBH 1.19

<TS 14 A

2 159 11 03C

-0.13

<TS 15 A

3 14 10 04C 0.86

<TS 16 A

3 128 15 02C 0.85

<TS 17 A

3 144 10 04H 0.81

<TS 18 A

3 164 10 03H

-0.89

<TS 19 A

3 164 12 02C 0.83

<TS 20 A

4 55 14 DBC 0.38

<TS 21 A

4 115 13 04C 0.87

<TS 22 A

4 137 13 02C 0.87

<TS 23 A

4 157 13 02C 0.89

<TS 24 A

4 157 10 02C

-0.17

<TS 25 A

5 38 11 03H 0.92

<TS 26 A

5 130 13 02C 0.91

<TS 27 A

5 132 9

03C

-0.91

<TS 28 A

6 131 6

02H

-0.06

<TS 29 A

6 147 12 04H

-0.91

<TS 30 A

8 161 11 02C

-0.91

<TS 31 A

9 2

17 02C 0.19

<TS 32 A

9 4

9 02C

-0.17

<TS 33 A

9 32 14 DBC 1.42

<TS 34 A

9 36 13 02H

-0.86

<TS 35 A

10 7

12 02C 0.83

<TS 36 A

10 21 12 04H 0.9

<TS 37 A

10 29 9

02H 0.87

<TS 38 A

10 39 12 05H

-0.06

<TS 39 A

10 165 13 DBH 1.59

<TS 17 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 40 A

11 4

8 02C

-0.19

<TS 41 A

11 146 13 03C 0.92

<TS 42 A

12 3

15 02C 0.82

<TS 43 A

12 7

8 02C

-0.9

<TS 44 A

12 123 15 DBH 0.96

<TS 45 A

12 133 10 03C 0.17

<TS 46 A

12 137 10 02H

-0.8

<TS 47 A

12 159 10 05H 0.94

<TS 48 A

13 2

20 02H 0.89

<TS 49 A

13 2

13 02H

-0.86

<TS 50 A

13 4

16 02C 0.81

<TS 51 A

13 8

7 03C 0.79

<TS 52 A

13 8

8 02C

-0.25

<TS 53 A

13 32 24 05C

-0.26

<TS 54 A

13 34 17 03C

-0.98

<TS 55 A

13 36 13 05C 0.78

<TS 56 A

13 146 15 DBC

-1.17

<TS 57 A

13 158 10 03H 0.88

<TS 58 A

14 3

26 02C 0.96

<TS 59 A

14 59 19 05H 0.83

<TS 60 A

14 59 10 02H 0.92

<TS 61 A

15 2

9 03C

-0.15

<TS 62 A

15 14 10 05C 0.84

<TS 63 A

15 28 11 05H 1

<TS 64 A

15 36 8

02C

-0.87

<TS 65 A

15 62 11 04C

-0.13

<TS 66 A

15 154 13 DBC 1.5

<TS 67 A

15 156 8

03H

-0.13

<TS 68 A

16 9

9 03C 0.84

<TS 69 A

16 11 10 02H

-0.77

<TS 70 A

17 2

12 04H 0.85

<TS 71 A

17 58 14 02C 0.83

<TS 72 A

17 60 11 02C

-0.81

<TS 73 A

18 3

12 02H 0.83

<TS 74 A

18 3

11 02H

-0.86

<TS 75 A

18 23 10 VS4

-0.87

<TS 76 A

18 25 13 VS4

-0.92

<TS 77 A

18 49 11 VS4

-1.01

<TS 78 A

18 51 16 VS4

-0.94

<TS 18 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 79 A

18 53 14 DBH

-0.72

<TS 80 A

18 59 9

02H 0.9

<TS 81 A

19 56 17 DBC 0.98

<TS 82 A

19 64 20 DBC

-1.58

<TS 83 A

19 64 17 DBH

-1.58

<TS 84 A

19 64 7

DBH 1.72

<TS 85 A

19 112 13 04C 0.83

<TS 86 A

19 144 11 04C 0.9

<TS 87 A

20 3

10 02C

-0.85

<TS 88 A

20 57 10 02H 0.89

<TS 89 A

20 59 7

03C

-0.98

<TS 90 A

20 103 9

04H

-0.11

<TS 91 A

20 163 11 02C 0.13

<TS 92 A

20 163 10 02C 0.88

<TS 93 A

21 2

11 04H 0.83

<TS 94 A

21 60 11 04C

-0.9

<TS 95 A

21 64 13 DBH

-1.68

<TS 96 A

21 114 9

02H 0.11

<TS 97 A

22 3

14 02C

-0.92

<TS 98 A

22 9

11 02C

-0.9

<TS 99 A

22 53 14 DBH 0.42

<TS 100 A

22 159 12 02H 0.91

<TS 101 A

22 161 9

02H 0.9

<TS 102 A

22 163 13 02H

-0.8

<TS 103 A

23 4

12 02C

-0.87

<TS 104 A

23 40 12 VS4 0.91

<TS 105 A

23 40 21 VS4

-1.12

<TS 106 A

23 58 6

04C 0.94

<TS 107 A

23 60 7

02H

-0.87

<TS 108 A

23 62 13 02C 0.84

<TS 109 A

23 104 6

03C 0.18

<TS 110 A

23 104 9

03C

-0.9

<TS 111 A

23 122 13 VS4 0.83

<TS 112 A

24 33 11 01H 0.85

<TS 113 A

24 41 12 VS4

-0.94

<TS 114 A

24 61 15 03C

-0.88

<TS 115 A

24 161 15 02C 0.84

<TS 116 A

24 161 12 02C

-0.81

<TS 117 A

24 163 18 02C 0.8

<TS 19 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 118 A

25 56 11 03C

-0.94

<TS 119 A

25 60 13 03C 0.93

<TS 120 A

25 110 16 04C 0.75

<TS 121 A

26 3

17 02C

-0.85

<TS 122 A

26 5

13 02H

-0.15

<TS 123 A

26 5

13 02H

-0.8

<TS 124 A

26 51 10 02H 0.93

<TS 125 A

26 121 13 VS4

-0.73

<TS 126 A

26 121 16 VS4

-0.18

<TS 127 A

26 125 13 VS4

-0.05

<TS 128 A

26 161 15 03H 0.74

<TS 129 A

26 163 15 01H 0.95

<TS 130 A

27 6

10 02H

-0.84

<TS 131 A

27 8

14 02C

-0.92

<TS 132 A

27 10 7

05H

-0.13

<TS 133 A

27 10 8

05H 0.92

<TS 134 A

27 58 11 02H 0.93

<TS 135 A

28 3

13 02C

-0.92

<TS 136 A

28 5

14 DBC 1.51

<TS 137 A

28 19 21 VS4

-1.01

<TS 138 A

28 31 22 VS4

-0.93

<TS 139 A

28 35 13 DBH 0.86

<TS 140 A

28 43 10 VS4

-1.12

<TS 141 A

28 63 12 05H 0.99

<TS 142 A

28 63 18 VS4

-1.08

<TS 143 A

28 105 10 03C 0.15

<TS 144 A

28 161 9

01H

-0.91

<TS 145 A

29 64 13 05H 0.95

<TS 146 A

29 122 9

02H 0.91

<TS 147 A

29 162 14 01H

-0.76

<TS 148 A

30 35 9

02H 0.9

<TS 149 A

30 55 8

03H 0.9

<TS 150 A

30 57 8

04H 0.91

<TS 151 A

30 59 11 02C

-0.85

<TS 152 A

30 59 12 04C 0.87

<TS 153 A

31 4

12 02H

-0.84

<TS 154 A

31 42 8

02C 0.86

<TS 155 A

31 44 12 02C 0.92

<TS 156 A

31 60 8

02H 0.82

<TS 20 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 157 A

31 126 18 VS4

-0.77

<TS 158 A

31 126 11 VS4 0.29

<TS 159 A

31 128 20 VS4

-0.76

<TS 160 A

31 128 20 VS4 0.94

<TS 161 A

32 7

22 02C

-0.9

<TS 162 A

32 37 17 03H 0.92

<TS 163 A

32 37 10 03H 0.06

<TS 164 A

32 59 18 DBH 0.39

<TS 165 A

32 109 10 VS4

-0.24

<TS 166 A

32 145 20 VS4

-0.98

<TS 167 A

32 161 13 03H

-0.19

<TS 168 A

33 22 14 DBH 1.99

<TS 169 A

33 38 14 03H

-0.83

<TS 170 A

33 46 14 02H 0.83

<TS 171 A

33 48 12 02H 0.9

<TS 172 A

33 58 8

04H 0.91

<TS 173 A

33 62 12 04C

-0.78

<TS 174 A

33 116 10 02H

-0.78

<TS 175 A

33 116 9

03H 0.87

<TS 176 A

33 124 13 VS4 0.66

<TS 177 A

33 124 13 03C 0.92

<TS 178 A

34 15 14 VS4

-0.69

<TS 179 A

34 39 7

02H 0.85

<TS 180 A

34 57 11 04C 0.86

<TS 181 A

34 57 10 04H 0.97

<TS 182 A

34 59 10 04H 0.88

<TS 183 A

34 59 10 04H

-0.13

<TS 184 A

34 63 15 04C 0.88

<TS 185 A

34 63 15 DBC 1.3

<TS 186 A

34 109 16 04H 0.97

<TS 187 A

34 117 11 03C

-0.9

<TS 188 A

34 119 13 03H 0.92

<TS 189 A

34 121 12 03C 0.94

<TS 190 A

34 131 10 05C

-0.15

<TS 191 A

35 48 13 03C

-0.91

<TS 192 A

35 48 6

02C

-0.83

<TS 193 A

35 114 15 DBC 1.95

<TS 194 A

36 47 12 DBH

-1.5

<TS 195 A

36 49 16 02C

-0.89

<TS 21 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 196 A

36 59 10 03H 0.86

<TS 197 A

36 61 15 04H

-0.22

<TS 198 A

36 61 12 DBH 1.69

<TS 199 A

36 105 12 02C 0.85

<TS 200 A

36 109 11 VS4 0.09

<TS 201 A

36 117 11 03C 0.11

<TS 202 A

36 117 16 02H 0.83

<TS 203 A

37 6

12 02C

-0.9

<TS 204 A

37 6

9 02C 0.88

<TS 205 A

37 24 14 05C 0.93

<TS 206 A

37 30 8

05H

-0.88

<TS 207 A

37 30 9

05H 0.93

<TS 208 A

37 34 20 DBC 1.6

<TS 209 A

37 34 12 04H 0.91

<TS 210 A

37 36 12 04H

-0.09

<TS 211 A

37 36 10 04H

-0.81

<TS 212 A

37 38 19 03C 1

<TS 213 A

37 42 12 02H 0.84

<TS 214 A

37 48 13 04H

-0.84

<TS 215 A

37 50 10 04C 0.2

<TS 216 A

37 50 10 04H

-0.9

<TS 217 A

37 50 14 04H 0.92

<TS 218 A

37 52 16 04C

-0.88

<TS 219 A

37 56 12 04C

-0.99

<TS 220 A

37 56 13 05C

-0.13

<TS 221 A

37 56 12 05H 0.94

<TS 222 A

37 56 22 04H 1.03

<TS 223 A

37 60 14 03H

-0.9

<TS 224 A

37 62 18 04H 0.94

<TS 225 A

37 62 16 05H

-0.81

<TS 226 A

37 106 18 03C

-0.79

<TS 227 A

37 116 15 03C 0.87

<TS 228 A

37 128 15 VS4

-0.86

<TS 229 A

37 128 20 VS4 0.82

<TS 230 A

37 134 11 05H 0.88

<TS 231 A

38 11 11 05H 0.87

<TS 232 A

38 13 9

05C 0.89

<TS 233 A

38 17 16 05H

-0.15

<TS 234 A

38 35 18 03H 0.88

<TS 22 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 235 A

38 35 23 04H 0.86

<TS 236 A

38 35 20 05H 0.96

<TS 237 A

38 39 12 02C 0.82

<TS 238 A

38 45 12 03C

-0.94

<TS 239 A

38 47 9

03C

-0.2

<TS 240 A

38 47 12 02H 0.87

<TS 241 A

38 49 11 04C 0.88

<TS 242 A

38 49 13 DBC 1.49

<TS 243 A

38 51 30 04C 0.83

<TS 244 A

38 53 10 04H 0.89

<TS 245 A

38 53 9

05C

-0.97

<TS 246 A

38 59 13 05H

-0.17

<TS 247 A

38 59 15 04H 0.88

<TS 248 A

38 61 9

04H

-0.07

<TS 249 A

38 115 11 02C 0.87

<TS 250 A

38 115 5

02C

-0.9

<TS 251 A

38 119 13 02C 0.85

<TS 252 A

38 123 10 02C

-0.86

<TS 253 A

38 127 16 03H 0.92

<TS 254 A

39 10 14 DBH 1.94

<TS 255 A

39 14 13 05H

-0.19

<TS 256 A

39 26 6

04H 1

<TS 257 A

39 36 9

05H

-0.79

<TS 258 A

39 40 7

02H 0.96

<TS 259 A

39 42 11 04H

-0.77

<TS 260 A

39 42 12 03C

-0.99

<TS 261 A

39 46 12 04H

-0.79

<TS 262 A

39 58 12 04H

-0.91

<TS 263 A

39 62 9

05H 0.18

<TS 264 A

39 62 14 05H 1

<TS 265 A

39 104 12 04H 0.83

<TS 266 A

39 104 14 03C

-0.85

<TS 267 A

39 104 12 02C

-0.22

<TS 268 A

39 106 8

03C

-0.24

<TS 269 A

39 112 15 02C 0.94

<TS 270 A

39 120 19 04H 0.85

<TS 271 A

39 126 18 03C 0.9

<TS 272 A

39 130 11 DBC

-1.56

<TS 273 A

40 5

11 01C

-0.93

<TS 23 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*

Percent No SG Row Column in Depth Location Elevation TS 274 A

40 7

11 02C 0.91

<TS 275 A

40 35 12 02C 0.15

<TS 276 A

40 35 12 04H 0.87

<TS 277 A

40 49 12 04H 0.92

<TS 278 A

40 51 10 03H

-0.86

<TS 279 A

40 51 9

04H 0.84

<TS 280 A

40 51 8

03C 0.86

<TS 281 A

40 55 10 VS4 0.88

<TS 282 A

40 57 7

03H 0.95

<TS 283 A

40 59 15 05H 1.1

<TS 284 A

40 115 12 02C 0.83

<TS 285 A

40 117 10 03C

-0.24

<TS 286 A

40 125 15 02C 0.87

<TS 287 A

40 147 23 VS4

-0.15

<TS 288 A

40 147 28 VS4

-0.81

<TS 289 A

40 161 10 01H 0.84

<TS 290 A

41 6

13 02C

-0.11

<TS 291 A

41 8

12 02C

-0.17

<TS 292 A

41 16 12 05H

-0.85

<TS 293 A

41 20 11 05H 1.11

<TS 294 A

41 22 9

05H

-0.87

<TS 295 A

41 34 12 03H

-0.88

<TS 296 A

41 40 9

05C

-0.15

<TS 297 A

41 44 14 03C

-0.92

<TS 298 A

41 44 15 05C

-0.88

<TS 299 A

41 50 13 02C

-0.85

<TS 300 A

41 52 28 VS4

-0.9

<TS 301 A

41 52 11 03H 0.9

<TS 302 A

41 54 14 04C

-0.86

<TS 303 A

41 60 26 05H 0.92

<TS 304 A

41 60 9

04H 0.99

<TS 305 A

41 64 12 04H 0.89

<TS 306 A

41 108 15 03C 0.85

<TS 307 A

41 120 8

03C 0.94

<TS 308 A

41 126 14 02C

-0.85

<TS 309 A

41 160 12 03C

-0.15

<TS 310 A

41 160 9

03C 0.69

<TS 311 A

41 160 18 01H 0.88

<TS 312 A

42 5

12 02H 0.87

<TS 24 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 313 A

42 5

12 VS4

-0.89

<TS 314 A

42 5

8 VS4

-0.16

<TS 315 A

42 7

21 02C 0.91

<TS 316 A

42 7

9 02C 0.11

<TS 317 A

42 33 8

DBH

-1.54

<TS 318 A

42 33 13 DBC

-1.43

<TS 319 A

42 35 11 05C 0.99

<TS 320 A

42 41 29 VS4 0.81

<TS 321 A

42 41 35 VS4

-1

<TS 322 A

42 43 9

03C 0.92

<TS 323 A

42 43 11 VS4

-0.97

<TS 324 A

42 43 19 04H 0.85

<TS 325 A

42 45 10 04H 0.85

<TS 326 A

42 45 14 02H 0.83

<TS 327 A

42 55 8

03H

-0.91

<TS 328 A

42 57 13 03H 0.92

<TS 329 A

42 59 16 04H 0.88

<TS 330 A

42 59 11 VS4 0.88

<TS 331 A

42 63 11 02H 0.83

<TS 332 A

42 117 15 02C 0.88

<TS 333 A

42 123 19 DBH

-0.11

<TS 334 A

43 36 11 VS4 1.09

<TS 335 A

43 44 11 04C 0.89

<TS 336 A

43 46 17 DBH 2.12

<TS 337 A

43 46 10 VS4

-0.09

<TS 338 A

43 46 10 03H

-0.86

<TS 339 A

43 46 28 VS4

-0.79

<TS 340 A

43 46 14 VS4 1.03

<TS 341 A

43 52 8

03H

-0.91

<TS 342 A

43 60 12 VS4 0.57

<TS 343 A

43 106 13 03C 0.74

<TS 344 A

43 126 31 VS4 0.98

<TS 345 A

43 126 11 DBC 1.58

<TS 346 A

44 15 12 DBH

-1.63

<TS 347 A

44 21 27 VS4

-0.79

<TS 348 A

44 21 23 VS4

-0.14

<TS 349 A

44 21 26 VS4 0.72

<TS 350 A

44 37 12 05C

-0.88

<TS 351 A

44 41 20 VS4

-0.36

<TS 25 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 352 A

44 47 11 VS4

-0.69

<TS 353 A

44 49 23 05C

-0.88

<TS 354 A

44 49 30 VS4

-0.7

<TS 355 A

44 49 27 VS4

-0.15

<TS 356 A

44 49 19 04H 0.79

<TS 357 A

44 59 9

03H 0.84

<TS 358 A

44 109 15 03C 0.11

<TS 359 A

44 123 19 VS4

-0.72

<TS 360 A

44 123 21 VS4

-0.11

<TS 361 A

44 123 13 VS4 0.79

<TS 362 A

44 123 15 06H

-0.07

<TS 363 A

44 125 12 VS4

-0.57

<TS 364 A

44 127 13 03C

-0.22

<TS 365 A

44 127 10 03C

-1.05

<TS 366 A

44 129 12 03C 0.81

<TS 367 A

44 131 13 05C 0.87

<TS 368 A

44 143 14 05C 0.82

<TS 369 A

45 6

13 DBH 2

<TS 370 A

45 12 17 DBH 2

<TS 371 A

45 30 13 04H

-0.92

<TS 372 A

45 30 10 04H

-0.02

<TS 373 A

45 42 13 VS4 0.59

<TS 374 A

45 52 15 03H 0.88

<TS 375 A

45 60 13 06H 0.53

<TS 376 A

45 60 14 04H 0.92

<TS 377 A

45 62 9

05H 0.95

<TS 378 A

45 104 13 03C 0.83

<TS 379 A

45 104 9

02C 0.79

<TS 380 A

45 108 21 03C 0.83

<TS 381 A

45 122 15 03C

-0.85

<TS 382 A

45 124 10 02C

-0.83

<TS 383 A

45 124 15 VS4 0.88

<TS 384 A

45 128 9

03H

-0.17

<TS 385 A

45 132 12 03C

-0.88

<TS 386 A

45 134 17 03C 0.85

<TS 387 A

46 7

13 VS4 0.9

<TS 388 A

46 17 12 VS4

-0.22

<TS 389 A

46 37 8

03H 0.9

<TS 390 A

46 41 8

04H 0.92

<TS 26 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 391 A

46 47 15 02H 0.9

<TS 392 A

46 51 15 03H 0.86

<TS 393 A

46 53 27 VS4

-0.83

<TS 394 A

46 53 21 VS4 0.85

<TS 395 A

46 55 13 VS4

-0.9

<TS 396 A

46 55 18 VS4 0.88

<TS 397 A

46 57 12 VS4 0.92

<TS 398 A

46 65 26 VS4 0.9

<TS 399 A

46 69 15 VS4

-0.48

<TS 400 A

46 111 11 02C 0.9

<TS 401 A

46 111 7

02C

-0.9

<TS 402 A

46 125 13 VS4

-0.13

<TS 403 A

46 125 10 VS4 0.17

<TS 404 A

46 125 9

VS4 0.83

<TS 405 A

46 127 11 02C 0.88

<TS 406 A

46 141 15 04C 0.87

<TS 407 A

47 8

15 01H

-0.86

<TS 408 A

47 12 11 DBC 1.88

<TS 409 A

47 24 11 04H

-0.85

<TS 410 A

47 24 10 VS4 0.5

<TS 411 A

47 24 6

DBC

-1.55

<TS 412 A

47 34 13 03C 0.99

<TS 413 A

47 50 14 VS4 0.94

<TS 414 A

47 68 12 06H 0.75

<TS 415 A

47 70 17 04H 0.91

<TS 416 A

47 112 17 02C 0.9

<TS 417 A

47 122 33 VS4 0.79

<TS 418 A

47 122 27 VS4 0.17

<TS 419 A

47 124 23 VS4 0

<TS 420 A

47 124 26 VS4 0.79

<TS 421 A

47 124 10 VS4

-0.64

<TS 422 A

47 126 25 VS4

-0.8

<TS 423 A

47 126 26 VS4

-0.02

<TS 424 A

47 126 11 04C 0.09

<TS 425 A

48 7

24 01C 0.87

<TS 426 A

48 19 12 05H

-0.82

<TS 427 A

48 19 39 VS4

-0.9

<TS 428 A

48 19 29 VS4 0.81

<TS 429 A

48 21 27 VS4

-0.94

<TS 27 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 430 A

48 29 14 04H 0.83

<TS 431 A

48 29 18 03C 0.91

<TS 432 A

48 37 16 06H 0.84

<TS 433 A

48 41 36 VS4

-0.92

<TS 434 A

48 41 15 VS4 0.92

<TS 435 A

48 43 35 VS4

-0.85

<TS 436 A

48 43 10 VS4 0.15

<TS 437 A

48 43 19 VS4 0.83

<TS 438 A

48 43 9

02H 0.86

<TS 439 A

48 45 9

06H 0.79

<TS 440 A

48 53 10 VS4

-0.92

<TS 441 A

48 55 11 04H 0.88

<TS 442 A

48 69 15 VS4

-0.81

<TS 443 A

48 69 35 VS4 0.92

<TS 444 A

48 97 30 VS4 0.88

<TS 445 A

48 111 13 02C 0.85

<TS 446 A

48 123 11 04C 0.76

<TS 447 A

48 125 17 02C 0.77

<TS 448 A

48 125 18 02C 0.13

<TS 449 A

48 133 10 02C 0.85

<TS 450 A

48 159 8

01H 0.9

<TS 451 A

48 159 12 01H

-0.04

<TS 452 A

48 159 6

01H

-0.83

<TS 453 A

49 10 19 VS4 0.9

<TS 454 A

49 16 17 02C

-1.05

<TS 455 A

49 20 30 VS4

-0.83

<TS 456 A

49 20 24 VS4 0.94

<TS 457 A

49 24 14 VS4

-0.86

<TS 458 A

49 28 11 03C 0.99

<TS 459 A

49 32 7

DBC 1.46

<TS 460 A

49 36 15 03C 0.93

<TS 461 A

49 66 10 VS4

-0.66

<TS 462 A

49 66 15 VS4 0.04

<TS 463 A

49 66 18 VS4 0.81

<TS 464 A

49 68 9

04H

-0.15

<TS 465 A

49 70 18 VS4 0.92

<TS 466 A

49 70 11 DBC 1.89

<TS 467 A

49 74 19 VS4

-0.88

<TS 468 A

49 74 14 DBC 1.78

<TS 28 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 469 A

49 92 16 DBC 1.79

<TS 470 A

49 92 13 03C

-0.96

<TS 471 A

49 94 7

VS4 0.9

<TS 472 A

49 94 11 03C 0.18

<TS 473 A

49 94 10 02C 0.86

<TS 474 A

49 96 14 03C 0.83

<TS 475 A

49 96 10 02C

-0.94

<TS 476 A

49 98 6

03C 0.86

<TS 477 A

49 98 7

02C 0.83

<TS 478 A

49 112 11 VS4

-0.61

<TS 479 A

49 112 17 VS4

-0.2

<TS 480 A

49 122 8

04C 0.81

<TS 481 A

49 122 10 04C

-0.99

<TS 482 A

49 130 10 02C

-0.98

<TS 483 A

49 132 15 02C 0.88

<TS 484 A

49 134 12 03C

-0.68

<TS 485 A

49 138 9

04H

-1

<TS 486 A

49 138 8

04H

-0.19

<TS 487 A

49 158 10 01H 0.8

<TS 488 A

50 17 13 VS4

-0.93

<TS 489 A

50 19 13 VS4 0.68

<TS 490 A

50 19 8

DBC 1.41

<TS 491 A

50 21 18 DBH 1.66

<TS 492 A

50 21 9

DBC 1.61

<TS 493 A

50 29 11 04C 0.81

<TS 494 A

50 29 7

05H 0.99

<TS 495 A

50 39 10 04H 0.89

<TS 496 A

50 45 11 03H 0.89

<TS 497 A

50 45 12 VS5

-0.86

<TS 498 A

50 49 6

05H

-0.78

<TS 499 A

50 51 12 03H 0.9

<TS 500 A

50 55 10 05H 0.95

<TS 501 A

50 57 16 04H 0.58

<TS 502 A

50 57 10 05H 0.99

<TS 503 A

50 65 13 02H

-0.89

<TS 504 A

50 71 10 03H 0.82

<TS 505 A

50 91 12 VS4 0.94

<TS 506 A

50 97 13 02C 0.86

<TS 507 A

50 105 12 04C

-0.93

<TS 29 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 508 A

50 115 9

03C

-0.85

<TS 509 A

50 123 16 04C 0.09

<TS 510 A

50 127 12 03C

-0.88

<TS 511 A

50 127 8

03C 0.17

<TS 512 A

50 153 17 VS5 0.83

<TS 513 A

50 157 21 VS3 0.7

<TS 514 A

50 157 35 VS3

-0.72

<TS 515 A

51 16 19 VS4

-0.84

<TS 516 A

51 18 6

DBC

-1.74

<TS 517 A

51 18 6

DBC 1.57

<TS 518 A

51 20 28 VS3

-0.8

<TS 519 A

51 20 12 VS5

-0.07

<TS 520 A

51 24 7

02C

-0.93

<TS 521 A

51 30 10 06H

-0.95

<TS 522 A

51 38 8

04H

-0.79

<TS 523 A

51 40 19 DBH 1.86

<TS 524 A

51 54 10 04H 0.92

<TS 525 A

51 60 7

04H 0.88

<TS 526 A

51 64 12 05H 0.88

<TS 527 A

51 66 12 04H

-0.89

<TS 528 A

51 66 11 05H 0.95

<TS 529 A

51 70 14 05H 0.9

<TS 530 A

51 90 15 04C

-0.18

<TS 531 A

51 92 14 02C 0.88

<TS 532 A

51 102 14 03C 0.9

<TS 533 A

51 104 10 04C

-0.88

<TS 534 A

51 108 10 03C

-0.99

<TS 535 A

51 116 8

04C

-0.17

<TS 536 A

51 116 7

05H 0.92

<TS 537 A

51 118 17 02C

-0.88

<TS 538 A

51 122 14 02C

-0.2

<TS 539 A

51 124 14 04C

-0.87

<TS 540 A

51 126 13 03C

-0.88

<TS 541 A

51 126 17 02C 0.09

<TS 542 A

51 126 12 02C 0.81

<TS 543 A

51 126 6

03C 0.96

<TS 544 A

51 134 12 VS3

-0.72

<TS 545 A

51 134 7

04C 0.11

<TS 546 A

51 134 7

04C 0.85

<TS 30 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 547 A

51 154 11 VS5

-0.79

<TS 548 A

51 154 11 VS3

-1.05

<TS 549 A

52 9

9 01C

-0.97

<TS 550 A

52 19 8

06H

-0.22

<TS 551 A

52 23 11 02C 0.81

<TS 552 A

52 25 10 04H 0.98

<TS 553 A

52 31 16 03C 0.93

<TS 554 A

52 33 10 06H 0.88

<TS 555 A

52 53 11 03H 0.81

<TS 556 A

52 55 12 03H

-0.85

<TS 557 A

52 89 10 06C 0.88

<TS 558 A

52 89 8

03C 0.86

<TS 559 A

52 91 9

05H

-0.81

<TS 560 A

52 97 15 02C

-0.92

<TS 561 A

52 97 12 VS5

-0.73

<TS 562 A

52 109 9

04C

-0.98

<TS 563 A

52 111 20 02C 0.87

<TS 564 A

52 115 9

04C

-0.81

<TS 565 A

52 117 21 02C 0.9

<TS 566 A

52 125 12 VS5

-0.68

<TS 567 A

52 127 9

VS5

-0.7

<TS 568 A

52 149 14 VS4

-0.87

<TS 569 A

52 149 18 VS3 0.87

<TS 570 A

53 10 13 01H

-0.78

<TS 571 A

53 10 10 VS4

-0.84

<TS 572 A

53 10 9

01C

-0.2

<TS 573 A

53 10 15 01C

-0.97

<TS 574 A

53 24 7

DBH

-1.67

<TS 575 A

53 52 11 04H

-0.85

<TS 576 A

53 56 16 03H 0.85

<TS 577 A

53 80 7

02H

-0.91

<TS 578 A

53 80 8

03H

-0.97

<TS 579 A

53 80 9

03H 0.78

<TS 580 A

53 88 10 03C

-0.9

<TS 581 A

53 90 11 03C 0.53

<TS 582 A

53 92 16 03C 0.81

<TS 583 A

53 94 9

04C 0.83

<TS 584 A

53 94 8

03C 0.88

<TS 585 A

53 94 11 03C 0.15

<TS 31 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 586 A

53 100 10 02C

-0.92

<TS 587 A

53 104 12 03C 0.85

<TS 588 A

53 112 9

04C

-0.9

<TS 589 A

53 118 15 02C 0.85

<TS 590 A

53 122 10 04C 0.87

<TS 591 A

53 122 19 02C

-0.13

<TS 592 A

53 122 5

04C

-0.92

<TS 593 A

53 136 6

DBC 1.77

<TS 594 A

53 142 13 03C 0.46

<TS 595 A

54 9

11 01C

-0.15

<TS 596 A

54 21 8

DBC 1.43

<TS 597 A

54 21 7

06H

-0.22

<TS 598 A

54 23 9

03H 0.83

<TS 599 A

54 29 16 02C 0.73

<TS 600 A

54 33 12 03H 0.85

<TS 601 A

54 39 9

05H 0.88

<TS 602 A

54 39 9

03H 0.9

<TS 603 A

54 63 9

02H 0.84

<TS 604 A

54 81 20 DBH 1.48

<TS 605 A

54 83 9

02H 0.9

<TS 606 A

54 83 15 03H 0.98

<TS 607 A

54 83 11 04H

-0.06

<TS 608 A

54 83 17 DBH

-0.35

<TS 609 A

54 93 8

04C

-0.9

<TS 610 A

54 93 8

03C 0.88

<TS 611 A

54 93 13 02C 0.9

<TS 612 A

54 95 10 02C

-0.9

<TS 613 A

54 99 11 VS4 0.86

<TS 614 A

54 105 15 02C 0.85

<TS 615 A

54 109 11 04C 0.92

<TS 616 A

54 119 14 02C 0.89

<TS 617 A

54 139 8

DBC 1.75

<TS 618 A

54 143 12 04C 0.9

<TS 619 A

55 8

15 01C

-0.22

<TS 620 A

55 38 6

05C

-0.09

<TS 621 A

55 46 13 04H

-0.93

<TS 622 A

55 78 9

04H 0.91

<TS 623 A

55 80 9

02H 0.89

<TS 624 A

55 82 12 02H

-0.89

<TS 32 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 625 A

55 84 9

02C 0.11

<TS 626 A

55 86 10 DBH 1.98

<TS 627 A

55 88 13 02C

-0.9

<TS 628 A

55 96 10 03C

-0.92

<TS 629 A

55 96 11 02C

-0.22

<TS 630 A

55 106 12 06H 0.88

<TS 631 A

55 112 9

03C

-0.13

<TS 632 A

55 112 10 04C

-0.94

<TS 633 A

55 114 14 02C 0.83

<TS 634 A

55 114 10 03C 0.77

<TS 635 A

55 114 7

03C

-0.96

<TS 636 A

55 120 12 02C

-0.23

<TS 637 A

55 122 14 02C

-0.15

<TS 638 A

55 140 19 06C

-0.09

<TS 639 A

56 27 11 03H

-0.89

<TS 640 A

56 29 9

06H

-0.81

<TS 641 A

56 33 9

03H

-0.89

<TS 642 A

56 39 11 04H

-0.09

<TS 643 A

56 41 11 02H

-0.13

<TS 644 A

56 59 10 03H 0.86

<TS 645 A

56 59 10 04H 0.88

<TS 646 A

56 81 17 DBH 1.79

<TS 647 A

56 83 7

04C 0.86

<TS 648 A

56 115 13 03C

-0.92

<TS 649 A

56 115 18 02C 0.83

<TS 650 A

56 137 17 03C 0.13

<TS 651 A

56 141 13 04C 0.94

<TS 652 A

57 10 12 01C

-0.18

<TS 653 A

57 18 13 VS3

-0.92

<TS 654 A

57 32 10 06H

-0.09

<TS 655 A

57 64 12 02H 0.95

<TS 656 A

57 90 9

03C

-0.2

<TS 657 A

57 90 10 04C

-0.2

<TS 658 A

57 110 13 02C 0.86

<TS 659 A

57 110 8

02C

-0.18

<TS 660 A

57 114 12 03C

-0.9

<TS 661 A

57 136 9

03C

-0.81

<TS 662 A

57 138 11 02C 0.88

<TS 663 A

57 142 14 04C

-0.94

<TS 33 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 664 A

57 142 13 04C

-0.13

<TS 665 A

57 142 16 03C 0.87

<TS 666 A

58 33 15 DBH 1.62

<TS 667 A

58 33 11 04H

-0.87

<TS 668 A

58 57 7

04H 0.9

<TS 669 A

58 57 7

03H 1.03

<TS 670 A

58 81 10 03H 0

<TS 671 A

58 81 10 02H

-0.15

<TS 672 A

58 85 12 03H 0.91

<TS 673 A

58 85 8

02H

-0.89

<TS 674 A

58 87 15 02C

-0.77

<TS 675 A

58 105 8

05H 0

<TS 676 A

58 113 10 04C 0.9

<TS 677 A

58 115 10 04C 0.88

<TS 678 A

58 121 10 03C 0.78

<TS 679 A

58 121 13 02C 0.83

<TS 680 A

58 123 10 03C 0

<TS 681 A

58 127 22 04C 0.83

<TS 682 A

58 127 8

04C 0

<TS 683 A

58 143 11 03C 0.82

<TS 684 A

59 30 15 03C 0.78

<TS 685 A

59 30 6

03H 0.94

<TS 686 A

59 30 10 03H

-0.89

<TS 687 A

59 38 11 03H 0.81

<TS 688 A

59 50 13 06H 0.87

<TS 689 A

59 56 14 DBH

-0.92

<TS 690 A

59 56 10 VS4 0.83

<TS 691 A

59 60 7

04H 0.85

<TS 692 A

59 66 14 06C 0.86

<TS 693 A

59 70 7

03H

-0.82

<TS 694 A

59 70 9

03H 0.95

<TS 695 A

59 82 15 03H 0.79

<TS 696 A

59 90 13 02C

-0.92

<TS 697 A

59 106 14 02C 0.81

<TS 698 A

59 114 11 03C

-1.03

<TS 699 A

59 114 15 03C 0.77

<TS 700 A

59 118 10 02C

-0.24

<TS 701 A

59 118 11 02C 0.83

<TS 702 A

59 120 11 02C

-0.88

<TS 34 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 703 A

59 126 11 06H 0.85

<TS 704 A

59 144 13 04C 0.89

<TS 705 A

60 11 11 01C 0.13

<TS 706 A

60 25 14 04H 0.86

<TS 707 A

60 27 10 03C 0.85

<TS 708 A

60 29 18 04H 0.94

<TS 709 A

60 31 10 03H 0.87

<TS 710 A

60 33 16 DBC 1.49

<TS 711 A

60 39 12 04H 0.92

<TS 712 A

60 39 9

05H

-0.06

<TS 713 A

60 39 14 06H 0.94

<TS 714 A

60 83 10 DBH

-1.89

<TS 715 A

60 85 11 02C 0.9

<TS 716 A

60 103 11 05H 0.93

<TS 717 A

60 119 21 02C 0.88

<TS 718 A

60 121 20 02C 0.9

<TS 719 A

61 20 11 DBC 1.43

<TS 720 A

61 34 13 03H 0.87

<TS 721 A

61 34 8

04H 0.91

<TS 722 A

61 36 9

03H

-0.78

<TS 723 A

61 40 10 04H 0.85

<TS 724 A

61 44 12 04H

-0.13

<TS 725 A

61 48 13 06H 0.86

<TS 726 A

61 54 10 03H

-0.85

<TS 727 A

61 56 10 03H

-0.98

<TS 728 A

61 86 12 03C

-0.13

<TS 729 A

61 104 7

02C

-0.9

<TS 730 A

61 108 10 03H

-0.88

<TS 731 A

61 112 15 04C

-0.97

<TS 732 A

61 120 11 VS4

-0.92

<TS 733 A

61 120 11 04C

-0.91

<TS 734 A

61 120 10 03C 0.95

<TS 735 A

61 138 14 DBC 1.45

<TS 736 A

61 138 13 04C 0.94

<TS 737 A

61 144 10 DBH 1.8

<TS 738 A

61 150 13 DBC 1.16

<TS 739 A

62 11 14 01C

-0.95

<TS 740 A

62 15 10 06C 0.79

<TS 741 A

62 19 12 06H 1.04

<TS 35 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 742 A

62 33 19 03H 0.92

<TS 743 A

62 35 13 03H 0.9

<TS 744 A

62 49 15 05H 0.91

<TS 745 A

62 59 9

04H 0.85

<TS 746 A

62 73 11 04H

-0.09

<TS 747 A

62 89 10 03C

-1.04

<TS 748 A

62 95 9

04C

-0.94

<TS 749 A

62 109 11 04H

-0.79

<TS 750 A

62 111 10 03H 0.19

<TS 751 A

62 121 13 02C 0.88

<TS 752 A

63 12 13 o1C

-0.93

<TS 753 A

63 40 7

DBC

-1.5

<TS 754 A

63 44 12 06C

-0.88

<TS 755 A

63 52 16 06C 0.88

<TS 756 A

63 58 11 03H 0.91

<TS 757 A

63 60 11 03H 0.97

<TS 758 A

63 62 12 04C 0.81

<TS 759 A

63 66 12 04H

-0.95

<TS 760 A

63 80 11 03H 0.93

<TS 761 A

63 82 10 06H 0.83

<TS 762 A

63 82 22 03H 0.89

<TS 763 A

63 82 8

02H

-0.92

<TS 764 A

63 84 10 DBH

-1.82

<TS 765 A

63 86 14 03C

-0.92

<TS 766 A

63 86 10 05C 0.86

<TS 767 A

63 86 15 02C

-0.88

<TS 768 A

63 102 14 04H 0.86

<TS 769 A

63 104 16 03C 0.85

<TS 770 A

63 104 12 04C

-0.22

<TS 771 A

63 104 11 05C

-0.9

<TS 772 A

63 106 15 03H 0.94

<TS 773 A

63 118 18 03C 0.9

<TS 774 A

63 122 20 03C 0.85

<TS 775 A

63 124 15 04C 0.87

<TS 776 A

63 124 8

04C

-0.15

<TS 777 A

63 126 16 04C 0.85

<TS 778 A

63 134 10 05C 0.92

<TS 779 A

63 134 13 03C 0.9

<TS 780 A

63 136 14 03C

-0.89

<TS 36 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 781 A

63 136 15 06H

-0.61

<TS 782 A

63 140 17 DBC 1.91

<TS 783 A

63 142 15 04C 0.88

<TS 784 A

64 11 30 VS4

-0.95

<TS 785 A

64 11 8

VS4 0.62

<TS 786 A

64 11 12 06H 0.84

<TS 787 A

64 11 18 VS5 0.71

<TS 788 A

64 13 15 04H 0.96

<TS 789 A

64 13 20 VS4

-0.93

<TS 790 A

64 19 7

06H 0

<TS 791 A

64 25 12 06C 0.84

<TS 792 A

64 29 10 DBC 1.74

<TS 793 A

64 37 12 VS3 0.24

<TS 794 A

64 37 10 VS4

-0.88

<TS 795 A

64 37 17 VS5 0.8

<TS 796 A

64 57 10 05H 0.89

<TS 797 A

64 57 14 06C 0.85

<TS 798 A

64 59 11 05C 0.92

<TS 799 A

64 59 6

04C 0.86

<TS 800 A

64 67 9

06C

-0.18

<TS 801 A

64 71 14 VS5 0.86

<TS 802 A

64 71 14 VS5

-0.9

<TS 803 A

64 83 13 03H 0.97

<TS 804 A

64 111 11 02H 0.92

<TS 805 A

64 123 16 04C 0.87

<TS 806 A

64 139 12 03C 0.96

<TS 807 A

64 153 11 01C

-0.93

<TS 808 A

65 12 20 06H 0.84

<TS 809 A

65 14 10 06H 0.81

<TS 810 A

65 16 12 05H 0.85

<TS 811 A

65 24 14 VS5 0.64

<TS 812 A

65 24 7

VS5

-0.82

<TS 813 A

65 32 8

DBC

-1.55

<TS 814 A

65 32 9

DBC 1.66

<TS 815 A

65 32 10 04H 0.87

<TS 816 A

65 40 12 03H 0.91

<TS 817 A

65 56 14 06C 0.86

<TS 818 A

65 56 10 03C

-0.92

<TS 819 A

65 60 10 02H

-0.91

<TS 37 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 820 A

65 60 7

04H

-0.86

<TS 821 A

65 60 10 03C 0.88

<TS 822 A

65 62 12 05C

-0.92

<TS 823 A

65 66 13 06H 0.9

<TS 824 A

65 76 11 02H

-0.19

<TS 825 A

65 88 10 02C

-0.9

<TS 826 A

65 90 13 02C 0.88

<TS 827 A

65 92 11 03C 0.81

<TS 828 A

65 92 8

02C 1.01

<TS 829 A

65 104 10 03H 0.48

<TS 830 A

65 104 6

04H 0.84

<TS 831 A

65 106 12 06C 0.88

<TS 832 A

65 106 18 04C 0.83

<TS 833 A

65 106 13 03C 0.85

<TS 834 A

65 106 17 02C 0.87

<TS 835 A

65 106 8

01C 0.13

<TS 836 A

65 108 17 03H

-0.9

<TS 837 A

65 110 13 03H

-0.86

<TS 838 A

65 116 14 VS3 0.85

<TS 839 A

65 120 11 03C 0.88

<TS 840 A

65 120 10 03C

-0.98

<TS 841 A

65 124 7

03C 1

<TS 842 A

65 126 17 06C

-0.9

<TS 843 A

65 138 26 04C

-0.13

<TS 844 A

65 152 20 VS3 0.98

<TS 845 A

66 13 10 VS4

-0.86

<TS 846 A

66 13 10 01C

-0.88

<TS 847 A

66 25 12 04H 0.87

<TS 848 A

66 27 15 06C 0.82

<TS 849 A

66 31 10 05H

-0.91

<TS 850 A

66 31 18 04H 0.93

<TS 851 A

66 35 13 04H 0.86

<TS 852 A

66 35 12 03H 0.9

<TS 853 A

66 37 9

06H

-0.09

<TS 854 A

66 39 7

05H 0.92

<TS 855 A

66 45 10 05H 0.99

<TS 856 A

66 49 9

05H 1

<TS 857 A

66 55 12 02H 0.88

<TS 858 A

66 59 14 06C 0.77

<TS 38 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 859 A

66 61 12 04H 0.87

<TS 860 A

66 63 7

02H

-0.84

<TS 861 A

66 63 10 06C 0.84

<TS 862 A

66 75 11 05H 0.89

<TS 863 A

66 77 10 06C 0.81

<TS 864 A

66 77 5

DBC

-1.94

<TS 865 A

66 79 8

03H

-0.83

<TS 866 A

66 79 10 01H

-0.17

<TS 867 A

66 83 12 06C 0.86

<TS 868 A

66 89 13 04C

-0.92

<TS 869 A

66 89 9

03C 0.02

<TS 870 A

66 107 15 03H 0.11

<TS 871 A

66 107 14 02C

-0.96

<TS 872 A

66 109 15 03H

-0.79

<TS 873 A

66 109 15 04C 0.92

<TS 874 A

66 109 14 04C 0.11

<TS 875 A

66 109 20 02C 0.87

<TS 876 A

66 111 10 02H

-0.9

<TS 877 A

66 111 13 02H 0.91

<TS 878 A

66 113 17 03H 0.92

<TS 879 A

66 113 15 02C 0.85

<TS 880 A

66 123 10 06C

-0.88

<TS 881 A

66 123 9

03C 0.92

<TS 882 A

66 129 8

DBH

-1.63

<TS 883 A

66 137 12 06C

-0.85

<TS 884 A

66 147 11 03C

-0.2

<TS 885 A

66 153 14 02C 0.88

<TS 886 A

66 153 10 02C

-0.87

<TS 887 A

67 12 11 03H 0.89

<TS 888 A

67 14 25 05H 0.74

<TS 889 A

67 20 16 VS5 0.71

<TS 890 A

67 24 22 06H 0.82

<TS 891 A

67 24 10 06C 0.84

<TS 892 A

67 24 8

06H 0.18

<TS 893 A

67 30 14 06C

-0.97

<TS 894 A

67 32 10 06H 0.88

<TS 895 A

67 34 10 06C 0.75

<TS 896 A

67 38 11 06H 0.92

<TS 897 A

67 38 6

06H

-0.15

<TS 39 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 898 A

67 50 13 03C 0.9

<TS 899 A

67 50 9

03C 0.11

<TS 900 A

67 56 11 VS3 0.97

<TS 901 A

67 58 12 04C 0.92

<TS 902 A

67 58 15 03C 0.09

<TS 903 A

67 58 15 02C 0.94

<TS 904 A

67 106 13 03H 0.88

<TS 905 A

67 106 10 02H 0.93

<TS 906 A

67 106 10 05C 0.79

<TS 907 A

67 106 8

03C 0.86

<TS 908 A

67 110 10 04H

-0.84

<TS 909 A

67 110 8

03C 0.88

<TS 910 A

67 112 12 VS3 0.85

<TS 911 A

67 112 12 04C

-0.85

<TS 912 A

67 114 12 03C

-0.92

<TS 913 A

67 114 24 02C 0.92

<TS 914 A

67 118 17 03C 0.92

<TS 915 A

67 120 11 06H

-0.09

<TS 916 A

67 120 11 06H 0.87

<TS 917 A

67 120 15 VS5 0.85

<TS 918 A

67 130 14 DBH 2.1

<TS 919 A

67 136 20 VS3 0.95

<TS 920 A

67 136 13 04C 0.92

<TS 921 A

67 138 14 03C 0.85

<TS 922 A

67 154 15 04C 0.86

<TS 923 A

67 154 17 02C 0.84

<TS 924 A

67 154 18 01C

-0.61

<TS 925 A

68 15 8

05H

-0.2

<TS 926 A

68 17 16 VS3

-0.75

<TS 927 A

68 17 7

VS4

-0.97

<TS 928 A

68 17 13 VS4 0.8

<TS 929 A

68 21 12 VS3

-0.83

<TS 930 A

68 21 22 VS4

-0.9

<TS 931 A

68 21 22 VS4 0.88

<TS 932 A

68 21 18 VS5 0.76

<TS 933 A

68 27 7

VS3

-0.93

<TS 934 A

68 39 6

VS3 0.92

<TS 935 A

68 41 14 04H 0.91

<TS 936 A

68 45 15 06H 0.94

<TS 40 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 937 A

68 53 12 04H

-0.22

<TS 938 A

68 61 10 03C

-0.88

<TS 939 A

68 61 12 06H 0.83

<TS 940 A

68 81 19 03H 0.88

<TS 941 A

68 87 10 03C

-0.86

<TS 942 A

68 103 10 02H

-0.9

<TS 943 A

68 105 9

04H 0.07

<TS 944 A

68 107 9

03H

-0.11

<TS 945 A

68 111 12 03H

-0.86

<TS 946 A

68 111 11 04H

-0.85

<TS 947 A

68 139 32 VS3

-0.85

<TS 948 A

68 139 16 VS5

-0.85

<TS 949 A

68 139 38 VS5 0.72

<TS 950 A

68 141 22 DBH 1.77

<TS 951 A

69 22 17 VS3 0.8

<TS 952 A

69 22 26 VS4

-0.93

<TS 953 A

69 22 27 VS4 0.8

<TS 954 A

69 22 9

VS4

-0.24

<TS 955 A

69 22 27 VS5 0.76

<TS 956 A

69 30 13 DBC 1.48

<TS 957 A

69 34 14 DBH 1.92

<TS 958 A

69 34 12 06C 0.84

<TS 959 A

69 40 12 04H 0.89

<TS 960 A

69 40 8

DBH 1.96

<TS 961 A

69 50 11 DBH 1.54

<TS 962 A

69 54 15 03C

-0.87

<TS 963 A

69 56 8

06H 0.88

<TS 964 A

69 56 10 03C 0.86

<TS 965 A

69 58 8

02C 0.86

<TS 966 A

69 60 6

06H

-0.95

<TS 967 A

69 60 12 06H 0.88

<TS 968 A

69 68 12 05C

-0.88

<TS 969 A

69 76 11 04H

-0.89

<TS 970 A

69 76 6

04H 0.33

<TS 971 A

69 80 6

03H

-0.84

<TS 972 A

69 86 15 06C 0.86

<TS 973 A

69 90 10 03C

-0.84

<TS 974 A

69 102 7

04H 0.93

<TS 975 A

69 106 14 VS5 0.83

<TS 41 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 976 A

69 106 14 05C 0.9

<TS 977 A

69 108 15 04H 0.86

<TS 978 A

69 110 12 03C 0.94

<TS 979 A

69 112 14 06C 0.88

<TS 980 A

69 112 14 02C 0.94

<TS 981 A

69 116 10 03H 0.11

<TS 982 A

69 122 12 04C 0.85

<TS 983 A

69 126 10 DBC 1.75

<TS 984 A

69 132 15 03C 0.87

<TS 985 A

69 134 19 06C

-0.85

<TS 986 A

69 136 12 VS3

-0.96

<TS 987 A

69 136 13 VS5 0.76

<TS 988 A

69 152 24 VS3 0.94

<TS 989 A

69 152 23 VS3

-0.86

<TS 990 A

70 15 12 VS4

-0.9

<TS 991 A

70 19 10 05H 1.11

<TS 992 A

70 29 6

DBC 1.94

<TS 993 A

70 53 11 04H 0.81

<TS 994 A

70 53 9

05H

-0.17

<TS 995 A

70 53 19 03C 0.11

<TS 996 A

70 53 13 02C

-0.84

<TS 997 A

70 55 21 03C

-0.98

<TS 998 A

70 57 6

DBH

-1.82

<TS 999 A

70 59 11 DBC 1.75

<TS 1000 A

70 61 11 04C 0.86

<TS 1001 A

70 65 8

04C 1.01

<TS 1002 A

70 69 10 05H

-0.17

<TS 1003 A

70 81 10 03H 0.92

<TS 1004 A

70 81 12 VS5

-0.72

<TS 1005 A

70 81 17 DBC 1.77

<TS 1006 A

70 85 13 03H 0.87

<TS 1007 A

70 107 16 04C

-0.85

<TS 1008 A

70 107 9

04H 0.13

<TS 1009 A

70 109 15 03C 0.88

<TS 1010 A

70 115 13 DBH 1.62

<TS 1011 A

70 115 13 03H 0.95

<TS 1012 A

70 119 16 04C 0.85

<TS 1013 A

70 123 13 03C

-0.85

<TS 1014 A

70 129 12 DBC 1.75

<TS 42 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1015 A

70 137 17 06H 0.85

<TS 1016 A

70 143 14 DBH 1.95

<TS 1017 A

70 145 13 DBC

-1.91

<TS 1018 A

70 145 13 VS3 0.81

<TS 1019 A

70 153 24 VS3

-0.91

<TS 1020 A

70 153 15 VS3 0.91

<TS 1021 A

70 153 11 02C

-0.82

<TS 1022 A

70 153 13 DBH

-1.64

<TS 1023 A

71 34 9

03H

-0.84

<TS 1024 A

71 40 9

06C 0.86

<TS 1025 A

71 54 15 03C 0.83

<TS 1026 A

71 54 13 04H 1.04

<TS 1027 A

71 58 13 04C

-0.99

<TS 1028 A

71 78 17 06C

-0.9

<TS 1029 A

71 82 11 03H 0.86

<TS 1030 A

71 90 6

05C 0.9

<TS 1031 A

71 104 11 VS3 0.9

<TS 1032 A

71 108 11 06C 0.86

<TS 1033 A

71 108 12 05C 0.88

<TS 1034 A

71 108 11 04C 0.13

<TS 1035 A

71 108 11 03C

-0.94

<TS 1036 A

71 108 13 02C

-0.15

<TS 1037 A

71 110 12 03H

-0.17

<TS 1038 A

71 110 15 04H 0.81

<TS 1039 A

71 116 10 03C 0.86

<TS 1040 A

71 122 13 03C 0.79

<TS 1041 A

71 126 22 05C 0.88

<TS 1042 A

71 126 8

05C 0.13

<TS 1043 A

71 126 11 VS5

-0.85

<TS 1044 A

71 126 9

VS5 0.83

<TS 1045 A

71 134 18 VS3

-0.77

<TS 1046 A

71 150 14 06H 0.91

<TS 1047 A

72 29 7

DBC 1.98

<TS 1048 A

72 47 9

04C

-0.22

<TS 1049 A

72 53 8

04C 0.91

<TS 1050 A

72 53 13 04C

-0.94

<TS 1051 A

72 53 16 02C 0.86

<TS 1052 A

72 55 13 04C

-0.18

<TS 1053 A

72 55 15 03C

-0.92

<TS 43 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1054 A

72 61 15 04C

-0.88

<TS 1055 A

72 85 10 05C 0.13

<TS 1056 A

72 89 10 02C 0.88

<TS 1057 A

72 109 10 04H 0.15

<TS 1058 A

72 111 10 04H 0.92

<TS 1059 A

72 127 16 VS4

-0.07

<TS 1060 A

72 127 18 04C 0.88

<TS 1061 A

72 131 12 DBH 1.93

<TS 1062 A

72 143 20 DBC 1.99

<TS 1063 A

72 149 17 DBH 1.97

<TS 1064 A

72 151 11 01H

-0.11

<TS 1065 A

73 14 14 05H

-0.98

<TS 1066 A

73 14 18 VS4

-1

<TS 1067 A

73 14 15 VS4 0.89

<TS 1068 A

73 44 20 06C

-0.96

<TS 1069 A

73 44 16 04H 0.91

<TS 1070 A

73 46 10 04H 0.94

<TS 1071 A

73 56 13 05C

-0.9

<TS 1072 A

73 66 17 04C 0.79

<TS 1073 A

73 110 11 03H

-0.86

<TS 1074 A

73 112 12 03C 0.9

<TS 1075 A

73 124 13 06C 0.92

<TS 1076 A

73 134 17 06C

-0.83

<TS 1077 A

73 152 15 VS3

-0.83

<TS 1078 A

73 152 15 VS3 0.98

<TS 1079 A

74 15 19 VS4 1.1

<TS 1080 A

74 15 11 01C

-0.95

<TS 1081 A

74 19 12 DBC 1.43

<TS 1082 A

74 33 12 DBC 1.48

<TS 1083 A

74 59 7

02C 0.9

<TS 1084 A

74 79 13 05C

-0.88

<TS 1085 A

74 121 13 03H

-0.86

<TS 1086 A

74 123 9

04H

-0.84

<TS 1087 A

74 123 11 05C

-0.92

<TS 1088 A

74 123 15 04C 0.94

<TS 1089 A

74 125 14 03H

-0.9

<TS 1090 A

74 127 12 03C 1

<TS 1091 A

74 129 10 VS5

-0.86

<TS 1092 A

74 145 14 DBC 1.8

<TS 44 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1093 A

74 149 11 DBC 1.51

<TS 1094 A

75 16 17 03H 0.43

<TS 1095 A

75 16 29 VS5

-1

<TS 1096 A

75 16 15 06C 0.02

<TS 1097 A

75 20 14 03H 0.87

<TS 1098 A

75 20 14 04H

-0.81

<TS 1099 A

75 28 15 DBH 1.81

<TS 1100 A

75 32 12 DBH 1.76

<TS 1101 A

75 40 12 06C 0.85

<TS 1102 A

75 44 37 VS3

-1.01

<TS 1103 A

75 44 22 VS3 0.99

<TS 1104 A

75 48 10 DBH

-1.59

<TS 1105 A

75 48 14 01C

-0.84

<TS 1106 A

75 50 24 VS3

-0.86

<TS 1107 A

75 50 18 VS3 0.86

<TS 1108 A

75 56 14 03C 0.84

<TS 1109 A

75 58 14 VS3 1.01

<TS 1110 A

75 68 15 02C 0.85

<TS 1111 A

75 76 13 02H 0.9

<TS 1112 A

75 76 12 02H

-0.91

<TS 1113 A

75 82 11 03H 0.89

<TS 1114 A

75 92 11 06H

-0.78

<TS 1115 A

75 104 14 02C

-0.85

<TS 1116 A

75 110 12 DBC

-1.48

<TS 1117 A

75 114 15 VS3

-0.83

<TS 1118 A

75 120 15 03C 0.81

<TS 1119 A

75 126 12 DBH 1.8

<TS 1120 A

75 128 14 VS5 0.9

<TS 1121 A

75 136 15 04C 0.9

<TS 1122 A

75 136 8

04C

-0.11

<TS 1123 A

75 148 12 06C 0.88

<TS 1124 A

75 150 17 02C 0.81

<TS 1125 A

75 150 13 04C 0.84

<TS 1126 A

76 15 34 DBC

-1.76

<TS 1127 A

76 15 11 DBC 1.98

<TS 1128 A

76 15 11 06C 0.85

<TS 1129 A

76 15 12 01C 0.2

<TS 1130 A

76 15 11 03H

-0.2

<TS 1131 A

76 15 10 04H

-0.8

<TS 45 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1132 A

76 17 14 DBC 1.66

<TS 1133 A

76 19 11 DBC 1.7

<TS 1134 A

76 21 12 03H 0.87

<TS 1135 A

76 21 13 04H 0.84

<TS 1136 A

76 37 9

06H

-0.13

<TS 1137 A

76 51 14 VS4 0.95

<TS 1138 A

76 51 6

VS3 0.95

<TS 1139 A

76 51 8

VS3

-0.9

<TS 1140 A

76 51 11 04C 0.11

<TS 1141 A

76 53 14 03C 0.9

<TS 1142 A

76 55 21 03C 0.9

<TS 1143 A

76 57 11 05C

-0.9

<TS 1144 A

76 57 14 02C 0.79

<TS 1145 A

76 65 10 04C

-0.11

<TS 1146 A

76 69 14 04H

-0.21

<TS 1147 A

76 79 11 03H 0.92

<TS 1148 A

76 91 16 02C 0.83

<TS 1149 A

76 97 8

04C

-0.92

<TS 1150 A

76 97 11 04C 0.9

<TS 1151 A

76 101 15 02H

-0.88

<TS 1152 A

76 101 13 03H 0.88

<TS 1153 A

76 103 10 03H

-0.04

<TS 1154 A

76 107 9

05C 0.92

<TS 1155 A

76 111 14 05C 0.81

<TS 1156 A

76 111 18 04C 0.9

<TS 1157 A

76 131 15 VS4 0.99

<TS 1158 A

76 151 12 VS4 0.89

<TS 1159 A

77 16 29 VS4

-0.97

<TS 1160 A

77 16 14 DBC 1.63

<TS 1161 A

77 18 16 05H

-0.99

<TS 1162 A

77 18 10 07C

-0.02

<TS 1163 A

77 18 12 06H

-0.55

<TS 1164 A

77 20 10 06H

-0.24

<TS 1165 A

77 20 11 DBC

-1.28

<TS 1166 A

77 22 14 06H 0.93

<TS 1167 A

77 22 10 03H 0.9

<TS 1168 A

77 24 16 06H 1

<TS 1169 A

77 24 9

03H 0.9

<TS 1170 A

77 24 9

04H

-0.15

<TS 46 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1171 A

77 28 9

06H 0.93

<TS 1172 A

77 44 23 VS5 0.97

<TS 1173 A

77 44 12 VS4 0.15

<TS 1174 A

77 44 13 VS4

-0.22

<TS 1175 A

77 44 19 VS3 0.79

<TS 1176 A

77 50 13 07C 0.4

<TS 1177 A

77 52 12 02C 1.01

<TS 1178 A

77 52 9

03C

-0.87

<TS 1179 A

77 52 10 06C

-0.86

<TS 1180 A

77 62 16 03C 0.88

<TS 1181 A

77 68 12 02H 0.92

<TS 1182 A

77 76 10 VS5 0.95

<TS 1183 A

77 82 14 05C 0.9

<TS 1184 A

77 92 15 02C

-0.92

<TS 1185 A

77 98 7

03H

-0.06

<TS 1186 A

77 98 6

03H

-0.91

<TS 1187 A

77 102 12 03H 0.89

<TS 1188 A

77 116 10 04H

-0.92

<TS 1189 A

77 122 18 06C 0.79

<TS 1190 A

77 124 16 03C 0.88

<TS 1191 A

77 124 12 03C

-0.9

<TS 1192 A

77 126 14 06H 0.9

<TS 1193 A

77 138 17 07C

-1.23

<TS 1194 A

77 144 10 04C 0.81

<TS 1195 A

77 148 24 03C 0.81

<TS 1196 A

77 148 16 07H

-0.99

<TS 1197 A

77 150 17 02C 0.88

<TS 1198 A

78 17 15 DBH

-1.57

<TS 1199 A

78 19 11 DBC

-1.78

<TS 1200 A

78 25 13 05C

-0.9

<TS 1201 A

78 25 11 DBC

-1.62

<TS 1202 A

78 75 13 02H 0.19

<TS 1203 A

78 87 12 01C 0.81

<TS 1204 A

78 101 14 03H 0.9

<TS 1205 A

78 105 14 VS3 0.83

<TS 1206 A

78 105 12 02H

-0.88

<TS 1207 A

78 109 9

04H

-0.09

<TS 1208 A

78 113 21 02C 0.85

<TS 1209 A

78 119 14 03H 0.88

<TS 47 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1210 A

78 119 13 02C 0.91

<TS 1211 A

78 127 11 03C 0.85

<TS 1212 A

78 147 15 02C

-0.18

<TS 1213 A

78 149 11 DBC

-1.66

<TS 1214 A

79 18 17 VS4

-0.97

<TS 1215 A

79 18 10 VS4 0.99

<TS 1216 A

79 18 13 DBC 1.7

<TS 1217 A

79 20 12 05H 0.87

<TS 1218 A

79 22 11 07C 0.93

<TS 1219 A

79 30 10 DBH

-1.7

<TS 1220 A

79 48 13 04C

-0.18

<TS 1221 A

79 68 14 07H 0.92

<TS 1222 A

79 68 13 04C

-0.9

<TS 1223 A

79 72 15 04H 0.87

<TS 1224 A

79 72 17 VS3

-0.09

<TS 1225 A

79 72 6

05H

-0.87

<TS 1226 A

79 74 11 05C

-0.9

<TS 1227 A

79 78 10 05C 0.84

<TS 1228 A

79 82 15 03H 0.86

<TS 1229 A

79 82 8

05C 0.88

<TS 1230 A

79 86 11 01C 0.86

<TS 1231 A

79 90 15 04C

-0.13

<TS 1232 A

79 94 12 03C

-0.92

<TS 1233 A

79 100 8

02H 0.86

<TS 1234 A

79 100 13 03H 0.88

<TS 1235 A

79 100 9

05H 0.87

<TS 1236 A

79 104 13 05H 0.91

<TS 1237 A

79 104 7

05H

-0.04

<TS 1238 A

79 114 11 02H

-0.8

<TS 1239 A

79 114 10 05C

-0.87

<TS 1240 A

79 116 11 03H

-0.86

<TS 1241 A

79 116 15 03C

-0.92

<TS 1242 A

79 120 11 04H 0.82

<TS 1243 A

79 128 22 04C 0.9

<TS 1244 A

79 144 15 VS5

-0.86

<TS 1245 A

79 144 24 VS5 0.89

<TS 1246 A

79 148 12 02C 0.86

<TS 1247 A

79 150 21 VS4 0.87

<TS 1248 A

79 150 14 02C 0.9

<TS 48 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1249 A

79 150 17 02C 0.09

<TS 1250 A

80 17 10 VS4 0.62

<TS 1251 A

80 27 13 VS3 0.95

<TS 1252 A

80 57 11 04H 0.11

<TS 1253 A

80 57 16 04H 0.93

<TS 1254 A

80 59 9

04C 0.83

<TS 1255 A

80 65 12 04C 0.81

<TS 1256 A

80 71 10 04H

-0.8

<TS 1257 A

80 77 18 04H 0.84

<TS 1258 A

80 77 10 02H

-0.91

<TS 1259 A

80 77 11 02H 0.89

<TS 1260 A

80 99 10 07C 0.9

<TS 1261 A

80 107 18 DBH 1.73

<TS 1262 A

80 119 10 03C 0.79

<TS 1263 A

80 125 13 05H 0.15

<TS 1264 A

80 133 9

04H

-0.9

<TS 1265 A

80 133 11 04H 0.88

<TS 1266 A

80 143 13 05C 0.85

<TS 1267 A

80 145 10 02C

-0.2

<TS 1268 A

80 147 17 07H 0.81

<TS 1269 A

80 149 18 VS4

-0.85

<TS 1270 A

81 18 12 01H 0.95

<TS 1271 A

81 18 12 VS4

-0.73

<TS 1272 A

81 18 9

DBC

-1.9

<TS 1273 A

81 20 11 04H 0.87

<TS 1274 A

81 20 9

04H

-0.21

<TS 1275 A

81 22 9

DBC

-1.32

<TS 1276 A

81 24 10 DBC

-1.06

<TS 1277 A

81 46 15 VS3 0.02

<TS 1278 A

81 46 14 VS3 0.88

<TS 1279 A

81 46 11 VS4

-0.88

<TS 1280 A

81 46 20 VS5 0.88

<TS 1281 A

81 54 14 05C

-0.9

<TS 1282 A

81 56 9

05C

-0.92

<TS 1283 A

81 70 13 VS4

-0.77

<TS 1284 A

81 84 28 VS4 0.86

<TS 1285 A

81 84 19 07C

-0.11

<TS 1286 A

81 84 12 05C

-0.9

<TS 1287 A

81 84 11 04C

-0.88

<TS 49 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1288 A

81 94 11 DBH 1.86

<TS 1289 A

81 94 11 02C

-0.9

<TS 1290 A

81 94 8

02C

-0.2

<TS 1291 A

81 94 10 VS4 0.88

<TS 1292 A

81 100 11 05H 0.89

<TS 1293 A

81 102 9

07C

-0.13

<TS 1294 A

81 102 13 07C

-0.9

<TS 1295 A

81 106 13 05C 0.86

<TS 1296 A

81 118 9

VS3

-0.99

<TS 1297 A

81 118 11 04C

-0.92

<TS 1298 A

81 118 9

03C

-0.83

<TS 1299 A

81 118 6

04C 0.96

<TS 1300 A

81 118 10 03C 0.79

<TS 1301 A

81 130 20 VS3

-0.72

<TS 1302 A

81 130 18 VS3

-0.13

<TS 1303 A

81 148 20 02C 0.8

<TS 1304 A

81 148 21 05C 0.07

<TS 1305 A

82 19 7

VS4

-0.97

<TS 1306 A

82 19 12 VS4 0.62

<TS 1307 A

82 33 17 VS3 0.9

<TS 1308 A

82 35 7

VS3 0.22

<TS 1309 A

82 61 12 VS3

-0.83

<TS 1310 A

82 71 10 VS3 0.9

<TS 1311 A

82 79 14 07C 0.79

<TS 1312 A

82 83 13 03C

-0.92

<TS 1313 A

82 89 18 05C 0.9

<TS 1314 A

82 91 11 07C 0.84

<TS 1315 A

82 101 10 DBH

-1.99

<TS 1316 A

82 101 9

05H

-0.11

<TS 1317 A

82 107 14 04H 0.87

<TS 1318 A

82 121 12 05H 0.91

<TS 1319 A

82 121 9

07C 0.9

<TS 1320 A

82 123 11 03C

-0.87

<TS 1321 A

82 135 17 VS3

-0.92

<TS 1322 A

82 141 19 VS3

-0.79

<TS 1323 A

83 50 13 05C 0.86

<TS 1324 A

83 54 12 07C

-0.9

<TS 1325 A

83 74 12 05H 0.91

<TS 1326 A

83 76 16 02H 0.96

<TS 50 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1327 A

83 84 10 04H

-0.8

<TS 1328 A

83 84 11 05H 0.93

<TS 1329 A

83 84 13 02C 0.83

<TS 1330 A

83 86 13 04H 0.89

<TS 1331 A

83 88 18 04C 0.9

<TS 1332 A

83 88 8

04C

-0.83

<TS 1333 A

83 90 17 07H 0.92

<TS 1334 A

83 90 10 05H

-0.13

<TS 1335 A

83 100 7

03H

-0.9

<TS 1336 A

83 100 17 04H 0.88

<TS 1337 A

83 100 9

05H 0.91

<TS 1338 A

83 102 13 05C

-0.87

<TS 1339 A

83 102 15 05C

-0.15

<TS 1340 A

83 108 10 04H 1.07

<TS 1341 A

83 112 16 02C

-0.15

<TS 1342 A

83 114 16 VS2

-0.79

<TS 1343 A

83 116 11 VS2

-0.24

<TS 1344 A

83 116 10 VS2 0.92

<TS 1345 A

83 118 13 03H 0.94

<TS 1346 A

83 120 9

04C 0.81

<TS 1347 A

83 122 18 VS2 0.83

<TS 1348 A

83 128 11 DBH 1.73

<TS 1349 A

83 136 11 DBH 1.58

<TS 1350 A

83 146 15 04C

-0.87

<TS 1351 A

83 148 15 VS4

-1.14

<TS 1352 A

83 148 15 VS4

-0.74

<TS 1353 A

83 148 14 07C 0.81

<TS 1354 A

83 148 20 03C

-0.9

<TS 1355 A

84 19 18 01H

-0.45

<TS 1356 A

84 19 12 VS3 0.31

<TS 1357 A

84 19 24 VS4

-0.95

<TS 1358 A

84 19 23 VS4 0.73

<TS 1359 A

84 19 18 VS5 0.95

<TS 1360 A

84 19 16 VS2 0.71

<TS 1361 A

84 25 9

VS2 0.64

<TS 1362 A

84 29 16 VS2 0.69

<TS 1363 A

84 29 12 05C

-0.97

<TS 1364 A

84 33 19 VS2

-0.82

<TS 1365 A

84 37 18 VS2

-0.8

<TS 51 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1366 A

84 39 10 VS2

-0.81

<TS 1367 A

84 39 18 VS3

-0.77

<TS 1368 A

84 41 13 07H 0.84

<TS 1369 A

84 45 13 VS6

-0.81

<TS 1370 A

84 47 10 06H 0.88

<TS 1371 A

84 51 11 VS2 0.62

<TS 1372 A

84 51 12 VS5 0.9

<TS 1373 A

84 53 24 VS2

-0.73

<TS 1374 A

84 61 11 03C 0.13

<TS 1375 A

84 61 29 03C 0.94

<TS 1376 A

84 73 14 05C 0.88

<TS 1377 A

84 73 7

05C 0.11

<TS 1378 A

84 73 11 04H 0.86

<TS 1379 A

84 73 9

02H 0.13

<TS 1380 A

84 75 9

06C

-0.9

<TS 1381 A

84 81 10 04H 0.87

<TS 1382 A

84 85 11 02H 0.89

<TS 1383 A

84 85 10 02H

-0.86

<TS 1384 A

84 85 11 04H

-0.87

<TS 1385 A

84 85 18 04H 0.87

<TS 1386 A

84 93 12 05C

-0.92

<TS 1387 A

84 93 11 04C

-0.88

<TS 1388 A

84 97 8

05H 0.22

<TS 1389 A

84 99 16 VS2

-0.88

<TS 1390 A

84 119 10 04C 0.98

<TS 1391 A

84 125 13 04C

-0.94

<TS 1392 A

84 141 23 04C 0.85

<TS 1393 A

84 143 13 03C 0.87

<TS 1394 A

84 147 25 VS3 0.77

<TS 1395 A

84 147 14 VS5 0.92

<TS 1396 A

85 20 25 VS4

-0.93

<TS 1397 A

85 20 23 VS4 0.62

<TS 1398 A

85 26 19 03H 0.8

<TS 1399 A

85 28 10 VS3

-0.78

<TS 1400 A

85 30 12 VS3

-0.89

<TS 1401 A

85 32 12 03C

-0.95

<TS 1402 A

85 32 14 VS5 0.84

<TS 1403 A

85 40 7

VS5

-0.99

<TS 1404 A

85 62 20 04C 0.5

<TS 52 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1405 A

85 84 12 05H 0.85

<TS 1406 A

85 92 16 02C 0.88

<TS 1407 A

85 94 10 02C 0.09

<TS 1408 A

85 104 13 03C 0.92

<TS 1409 A

85 116 16 03C 0.39

<TS 1410 A

85 124 11 03C 0.9

<TS 1411 A

85 130 12 04C

-0.94

<TS 1412 A

85 146 17 02C 0.79

<TS 1413 A

85 146 22 03C

-0.94

<TS 1414 A

86 21 14 VS4

-0.93

<TS 1415 A

86 35 13 VS6

-0.75

<TS 1416 A

86 35 13 VS6

-0.73

<TS 1417 A

86 51 10 VS2 0.88

<TS 1418 A

86 55 16 06C 0.9

<TS 1419 A

86 57 8

05C 0.88

<TS 1420 A

86 59 11 03C 0.87

<TS 1421 A

86 59 8

02C 0.92

<TS 1422 A

86 63 13 06C 0.9

<TS 1423 A

86 65 12 05H 0.89

<TS 1424 A

86 67 10 04C

-0.89

<TS 1425 A

86 67 8

02C 0.9

<TS 1426 A

86 69 10 06C

-0.9

<TS 1427 A

86 81 8

02H

-0.84

<TS 1428 A

86 85 7

05H

-0.13

<TS 1429 A

86 97 16 03H 0.88

<TS 1430 A

86 99 12 VS6

-0.35

<TS 1431 A

86 101 11 05C

-0.87

<TS 1432 A

86 101 15 04H

-0.92

<TS 1433 A

86 107 13 04H 0.85

<TS 1434 A

86 111 10 03H

-0.9

<TS 1435 A

86 111 12 04H 0.02

<TS 1436 A

86 111 17 05C 0.85

<TS 1437 A

86 115 12 02C

-0.99

<TS 1438 A

86 117 10 03H 0.85

<TS 1439 A

86 117 13 06C 0.89

<TS 1440 A

86 143 15 03C

-0.87

<TS 1441 A

86 145 13 03C

-0.87

<TS 1442 A

86 145 8

03C 0.92

<TS 1443 A

86 145 17 04C 0.86

<TS 53 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1444 A

86 145 10 02C 0.65

<TS 1445 A

87 20 15 VS4

-0.22

<TS 1446 A

87 20 23 VS4 0.64

<TS 1447 A

87 20 12 VS4

-0.91

<TS 1448 A

87 22 11 01H 0.9

<TS 1449 A

87 22 12 04H 0.83

<TS 1450 A

87 22 18 VS4

-0.93

<TS 1451 A

87 36 9

07C 0.82

<TS 1452 A

87 36 11 DBH 1.99

<TS 1453 A

87 40 16 07H

-0.95

<TS 1454 A

87 40 7

07H

-0.22

<TS 1455 A

87 40 9

VS2

-0.93

<TS 1456 A

87 40 16 07C 0.79

<TS 1457 A

87 40 8

VS4 0.6

<TS 1458 A

87 56 11 05H 0.91

<TS 1459 A

87 56 14 04C 0.92

<TS 1460 A

87 58 15 VS2

-0.9

<TS 1461 A

87 60 17 VS2

-0.84

<TS 1462 A

87 60 10 03C 0.88

<TS 1463 A

87 60 12 02C 0.84

<TS 1464 A

87 82 13 05H 0.95

<TS 1465 A

87 82 8

05C 0.9

<TS 1466 A

87 88 9

04H 0.31

<TS 1467 A

87 90 9

02C

-0.2

<TS 1468 A

87 90 10 04H 0.93

<TS 1469 A

87 92 10 02C 0.88

<TS 1470 A

87 92 18 04C 0.83

<TS 1471 A

87 92 15 05C 0.85

<TS 1472 A

87 92 10 04H 0.95

<TS 1473 A

87 92 11 04H

-0.74

<TS 1474 A

87 100 13 04H 0.84

<TS 1475 A

87 100 9

05C

-0.88

<TS 1476 A

87 102 20 05H 0.88

<TS 1477 A

87 102 10 04H

-0.09

<TS 1478 A

87 102 9

03H 0.83

<TS 1479 A

87 104 11 06H 0.94

<TS 1480 A

87 106 12 03H 0.85

<TS 1481 A

87 106 12 06H 0.24

<TS 1482 A

87 108 12 VS2 0.74

<TS 54 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1483 A

87 110 14 03H 0.77

<TS 1484 A

87 112 14 04H 0.88

<TS 1485 A

87 114 11 06H 0.15

<TS 1486 A

87 116 19 04C 0.83

<TS 1487 A

87 116 14 03C

-0.11

<TS 1488 A

87 120 12 VS2 0.17

<TS 1489 A

87 120 18 VS2 0.72

<TS 1490 A

87 120 11 05H

-0.15

<TS 1491 A

87 124 12 04C

-0.99

<TS 1492 A

87 136 10 03C

-0.97

<TS 1493 A

87 138 13 03H 0.87

<TS 1494 A

87 142 9

03C

-0.96

<TS 1495 A

87 144 22 03C

-0.86

<TS 1496 A

87 144 17 04C 0.88

<TS 1497 A

87 146 18 VS4

-0.96

<TS 1498 A

87 146 22 VS4 0.57

<TS 1499 A

87 146 14 02C 0.77

<TS 1500 A

88 21 25 VS4

-1

<TS 1501 A

88 21 8

VS4 0.2

<TS 1502 A

88 25 10 VS4

-0.68

<TS 1503 A

88 33 10 04H 0.84

<TS 1504 A

88 53 18 VS4 0.9

<TS 1505 A

88 53 22 07C 0.92

<TS 1506 A

88 57 13 06H 0.88

<TS 1507 A

88 57 15 VS6 0.72

<TS 1508 A

88 57 20 07C 0.94

<TS 1509 A

88 59 16 05C 0.86

<TS 1510 A

88 59 15 05C 0.15

<TS 1511 A

88 59 10 04C 0.84

<TS 1512 A

88 59 8

03C 0.93

<TS 1513 A

88 61 23 02C 0.9

<TS 1514 A

88 61 24 03C 0.46

<TS 1515 A

88 61 13 06C 0.9

<TS 1516 A

88 73 20 02H

-0.15

<TS 1517 A

88 81 13 02C 0.9

<TS 1518 A

88 83 15 04H

-0.76

<TS 1519 A

88 83 14 05H

-0.74

<TS 1520 A

88 89 16 06H 0.88

<TS 1521 A

88 89 9

05H 0.11

<TS 55 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1522 A

88 91 14 05C 0.13

<TS 1523 A

88 91 12 04H 0.94

<TS 1524 A

88 93 9

04H 0.89

<TS 1525 A

88 99 10 06H

-0.95

<TS 1526 A

88 107 9

04C 0.15

<TS 1527 A

88 117 13 06H 0.83

<TS 1528 A

88 125 12 03C

-0.89

<TS 1529 A

88 125 14 04C

-0.85

<TS 1530 A

88 145 22 VS4 0.77

<TS 1531 A

88 145 22 04C

-0.98

<TS 1532 A

88 145 33 02C 0.18

<TS 1533 A

89 26 16 VS6 0.84

<TS 1534 A

89 28 9

VS6 0.88

<TS 1535 A

89 34 11 04H

-0.92

<TS 1536 A

89 38 8

04H

-0.92

<TS 1537 A

89 42 9

07H

-1.06

<TS 1538 A

89 42 9

07H 0.86

<TS 1539 A

89 60 7

04H

-0.84

<TS 1540 A

89 70 12 05C

-0.9

<TS 1541 A

89 70 7

05C 0.18

<TS 1542 A

89 70 16 06C 0.88

<TS 1543 A

89 72 15 01C 0.83

<TS 1544 A

89 78 16 07H 0.98

<TS 1545 A

89 78 8

07H

-0.83

<TS 1546 A

89 84 11 04H

-0.85

<TS 1547 A

89 84 6

03H 0.91

<TS 1548 A

89 108 11 04H 1

<TS 1549 A

89 108 15 05H 0.92

<TS 1550 A

89 108 22 06H 0.86

<TS 1551 A

89 112 13 05H

-0.91

<TS 1552 A

89 112 14 05H 0.15

<TS 1553 A

89 112 16 05H 0.89

<TS 1554 A

89 114 11 03H

-0.89

<TS 1555 A

89 128 15 03H 0.86

<TS 1556 A

89 128 13 05H 0.91

<TS 1557 A

89 136 15 03H 0.92

<TS 1558 A

90 23 13 VS4

-0.9

<TS 1559 A

90 25 13 VS4 0.95

<TS 1560 A

90 25 6

VS4

-0.93

<TS 56 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1561 A

90 31 10 04H 0.87

<TS 1562 A

90 35 9

05H 0.92

<TS 1563 A

90 55 13 04C

-0.92

<TS 1564 A

90 59 7

04H

-0.15

<TS 1565 A

90 59 9

04H 0.88

<TS 1566 A

90 79 8

05H 1.01

<TS 1567 A

90 79 10 06C 0.83

<TS 1568 A

90 81 11 06H 0.9

<TS 1569 A

90 87 15 03H 0.95

<TS 1570 A

90 87 19 06H 0.55

<TS 1571 A

90 87 15 02C 0.88

<TS 1572 A

90 87 11 04C 0.33

<TS 1573 A

90 91 12 03C 0.94

<TS 1574 A

90 93 12 04C 0.9

<TS 1575 A

90 93 19 03C 0.75

<TS 1576 A

90 95 10 02C

-0.94

<TS 1577 A

90 95 18 04C 0.88

<TS 1578 A

90 95 18 06C 0.88

<TS 1579 A

90 95 11 07C 0.13

<TS 1580 A

90 99 10 07H

-0.9

<TS 1581 A

90 101 10 03H

-0.88

<TS 1582 A

90 101 16 02C 0.46

<TS 1583 A

90 103 7

04H 0.86

<TS 1584 A

90 105 21 05C 0.85

<TS 1585 A

90 107 13 04H 0.91

<TS 1586 A

90 107 15 05C 0.86

<TS 1587 A

90 109 12 05H

-0.85

<TS 1588 A

90 115 16 VS6

-0.77

<TS 1589 A

90 115 12 VS6

-0.22

<TS 1590 A

90 115 11 07C 0.83

<TS 1591 A

90 115 10 03C

-0.9

<TS 1592 A

90 115 18 VS2

-0.88

<TS 1593 A

90 115 9

VS2 0.92

<TS 1594 A

90 133 11 03C

-0.99

<TS 1595 A

90 135 13 04H 0.92

<TS 1596 A

90 135 15 04C 0.9

<TS 1597 A

90 137 16 06C 0.83

<TS 1598 A

90 137 9

04C 0.07

<TS 1599 A

90 143 21 02C

-0.88

<TS 57 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1600 A

90 143 18 02C 0.13

<TS 1601 A

90 143 18 03C

-0.81

<TS 1602 A

90 143 11 03C 0.02

<TS 1603 A

91 22 33 VS4 0.64

<TS 1604 A

91 22 13 VS6

-0.93

<TS 1605 A

91 26 8

03H 0.91

<TS 1606 A

91 36 10 06H

-0.89

<TS 1607 A

91 40 7

DBH 1.86

<TS 1608 A

91 48 16 07C 0.11

<TS 1609 A

91 48 13 05C

-0.9

<TS 1610 A

91 54 11 03C

-0.92

<TS 1611 A

91 60 10 03C

-0.95

<TS 1612 A

91 60 11 02C

-0.18

<TS 1613 A

91 66 17 05C 0.88

<TS 1614 A

91 70 12 VS6 1.01

<TS 1615 A

91 70 7

06H

-0.09

<TS 1616 A

91 80 12 07C 0.87

<TS 1617 A

91 80 14 05C 0.87

<TS 1618 A

91 86 12 05H 0.17

<TS 1619 A

91 90 19 03C 0.83

<TS 1620 A

91 90 9

04C 0.86

<TS 1621 A

91 90 15 05H 0.54

<TS 1622 A

91 92 10 05H 0.93

<TS 1623 A

91 94 11 05C 0.13

<TS 1624 A

91 94 7

06H 0.15

<TS 1625 A

91 94 12 05H 0.19

<TS 1626 A

91 96 11 02C 0.75

<TS 1627 A

91 106 14 03C 0.77

<TS 1628 A

91 110 11 04C

-0.9

<TS 1629 A

91 114 17 VS2

-0.87

<TS 1630 A

91 116 28 VS2

-0.72

<TS 1631 A

91 128 12 04H

-0.91

<TS 1632 A

91 134 12 04H

-1.03

<TS 1633 A

91 134 10 06C 0.48

<TS 1634 A

91 136 12 04C 0.79

<TS 1635 A

91 138 12 05C

-0.93

<TS 1636 A

91 138 13 04C 0.84

<TS 1637 A

91 138 14 VS2

-0.82

<TS 1638 A

91 138 7

04C

-0.94

<TS 58 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1639 A

91 144 13 VS4 0.66

<TS 1640 A

91 144 10 03C

-0.85

<TS 1641 A

92 23 11 04H 0.87

<TS 1642 A

92 23 19 VS2 0.55

<TS 1643 A

92 23 17 VS2 0.91

<TS 1644 A

92 23 24 VS6 1.09

<TS 1645 A

92 23 7

VS6 0.66

<TS 1646 A

92 25 12 VS4 0.93

<TS 1647 A

92 25 9

VS4

-0.99

<TS 1648 A

92 29 12 03H 0.87

<TS 1649 A

92 33 10 04H 0.87

<TS 1650 A

92 35 14 06H 0.97

<TS 1651 A

92 37 11 04H 0.89

<TS 1652 A

92 51 11 05C 0.07

<TS 1653 A

92 59 12 VS4 0.9

<TS 1654 A

92 59 11 VS6 1.1

<TS 1655 A

92 59 12 VS4

-0.9

<TS 1656 A

92 59 7

VS4 0.22

<TS 1657 A

92 69 14 05C 0.13

<TS 1658 A

92 69 12 05C 0.88

<TS 1659 A

92 77 12 06C

-0.96

<TS 1660 A

92 77 16 05C

-0.81

<TS 1661 A

92 81 12 05H 0.9

<TS 1662 A

92 81 13 06H

-0.8

<TS 1663 A

92 85 15 VS6 0.99

<TS 1664 A

92 87 13 05C 0.84

<TS 1665 A

92 87 11 03H 0.98

<TS 1666 A

92 89 17 04C 0.86

<TS 1667 A

92 89 15 05C 0.92

<TS 1668 A

92 89 15 06H 0.88

<TS 1669 A

92 93 16 04H 0.95

<TS 1670 A

92 93 12 02C 0.92

<TS 1671 A

92 97 9

05C

-0.02

<TS 1672 A

92 101 15 VS2 0.94

<TS 1673 A

92 101 16 VS2

-0.77

<TS 1674 A

92 105 11 04C 0.88

<TS 1675 A

92 107 11 04H

-0.13

<TS 1676 A

92 109 12 05C

-0.92

<TS 1677 A

92 111 12 04H 0.89

<TS 59 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1678 A

92 115 14 04C 0.79

<TS 1679 A

92 117 14 VS4

-0.81

<TS 1680 A

92 117 12 VS4 0.85

<TS 1681 A

92 125 11 03H 0.85

<TS 1682 A

92 127 10 04H 0

<TS 1683 A

92 129 11 07H

-0.83

<TS 1684 A

92 131 14 04H 0.93

<TS 1685 A

92 133 18 07H 0.87

<TS 1686 A

92 133 16 05C

-0.87

<TS 1687 A

92 133 20 04C 0.9

<TS 1688 A

92 133 14 03C

-0.92

<TS 1689 A

92 135 18 04C 0.81

<TS 1690 A

92 137 11 04C 0.85

<TS 1691 A

92 141 15 04C 0.88

<TS 1692 A

92 141 14 02C

-0.11

<TS 1693 A

93 26 13 VS4

-0.86

<TS 1694 A

93 26 11 VS4 0.86

<TS 1695 A

93 26 10 DBC 0.95

<TS 1696 A

93 52 18 04C 0.42

<TS 1697 A

93 60 12 VS6 1.01

<TS 1698 A

93 60 15 VS6

-0.98

<TS 1699 A

93 60 18 VS2 1.03

<TS 1700 A

93 60 16 VS2

-0.87

<TS 1701 A

93 70 12 04H 0.92

<TS 1702 A

93 70 14 02H

-0.83

<TS 1703 A

93 76 19 VS4 0.09

<TS 1704 A

93 76 17 VS4 0.76

<TS 1705 A

93 76 11 07C

-0.87

<TS 1706 A

93 82 9

VS2 0.92

<TS 1707 A

93 82 9

05C

-0.9

<TS 1708 A

93 84 9

03H

-0.78

<TS 1709 A

93 84 12 04H

-0.85

<TS 1710 A

93 88 14 03H 0.04

<TS 1711 A

93 94 11 04C

-0.66

<TS 1712 A

93 94 10 04C 0.84

<TS 1713 A

93 96 10 04C

-0.13

<TS 1714 A

93 100 13 VS2

-0.7

<TS 1715 A

93 104 35 VS4

-0.74

<TS 1716 A

93 104 13 DBH 1.67

<TS 60 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1717 A

93 104 27 VS6 0.94

<TS 1718 A

93 104 13 VS6

-0.94

<TS 1719 A

93 104 13 02C

-0.88

<TS 1720 A

93 106 21 VS2

-0.72

<TS 1721 A

93 106 8

VS2 0.07

<TS 1722 A

93 114 21 VS6 0.9

<TS 1723 A

93 114 16 03C

-0.81

<TS 1724 A

93 114 12 VS6

-0.9

<TS 1725 A

93 116 11 DBH 1.53

<TS 1726 A

93 118 7

DBH 1.73

<TS 1727 A

93 130 15 03H

-0.86

<TS 1728 A

93 130 12 04H

-0.81

<TS 1729 A

93 130 21 VS2

-0.76

<TS 1730 A

93 130 16 VS2 0.9

<TS 1731 A

93 130 20 VS4

-0.87

<TS 1732 A

93 130 38 VS4 0.98

<TS 1733 A

93 132 11 04H

-0.9

<TS 1734 A

93 134 11 04H

-0.83

<TS 1735 A

93 136 15 03C 0.82

<TS 1736 A

93 136 19 03C

-0.86

<TS 1737 A

93 138 17 05C 0.83

<TS 1738 A

94 25 15 VS4

-0.95

<TS 1739 A

94 25 6

VS4 0.15

<TS 1740 A

94 25 11 03H

-0.54

<TS 1741 A

94 27 14 03H 0.84

<TS 1742 A

94 31 21 VS4

-0.94

<TS 1743 A

94 51 16 04C 0.46

<TS 1744 A

94 57 12 VS6

-0.92

<TS 1745 A

94 57 12 05C 0.9

<TS 1746 A

94 61 11 04H 0.95

<TS 1747 A

94 67 20 VS6

-0.97

<TS 1748 A

94 67 14 VS6 0.75

<TS 1749 A

94 71 9

05C

-0.9

<TS 1750 A

94 77 16 VS2

-0.85

<TS 1751 A

94 77 28 VS2 0.92

<TS 1752 A

94 77 12 VS6

-0.9

<TS 1753 A

94 85 12 02C 0.84

<TS 1754 A

94 89 12 05C 0.64

<TS 1755 A

94 91 12 05H

-0.84

<TS 61 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1756 A

94 95 19 07C

-0.88

<TS 1757 A

94 101 20 04C

-0.94

<TS 1758 A

94 107 8

03H

-0.87

<TS 1759 A

94 109 14 04C

-0.9

<TS 1760 A

94 111 10 04H

-0.97

<TS 1761 A

94 129 10 03H

-0.88

<TS 1762 A

94 135 14 04C 0.85

<TS 1763 A

94 139 12 03C

-0.88

<TS 1764 A

94 141 16 03C 0.75

<TS 1765 A

95 24 28 VS4

-1.02

<TS 1766 A

95 24 18 VS4 0.31

<TS 1767 A

95 26 8

VS4 0.91

<TS 1768 A

95 30 34 VS4

-0.93

<TS 1769 A

95 30 29 VS4 0.86

<TS 1770 A

95 30 10 VS6

-0.07

<TS 1771 A

95 32 9

04H

-0.11

<TS 1772 A

95 48 8

07C 0.13

<TS 1773 A

95 48 19 06C 0.92

<TS 1774 A

95 48 11 07H 0.9

<TS 1775 A

95 48 7

06H 0.92

<TS 1776 A

95 48 8

07H

-0.86

<TS 1777 A

95 48 8

06C 0.11

<TS 1778 A

95 54 11 05C 0.09

<TS 1779 A

95 56 13 06C 0.86

<TS 1780 A

95 58 9

04H 1.16

<TS 1781 A

95 58 11 VS2

-0.92

<TS 1782 A

95 58 8

05C

-0.86

<TS 1783 A

95 60 12 06H 0.93

<TS 1784 A

95 72 14 07C 0.11

<TS 1785 A

95 72 11 07C 0.88

<TS 1786 A

95 74 12 06C

-0.91

<TS 1787 A

95 84 19 05C 0.88

<TS 1788 A

95 94 10 DBC 1.64

<TS 1789 A

95 94 13 04C 0

<TS 1790 A

95 104 13 02C 0.09

<TS 1791 A

95 104 10 04C 0.11

<TS 1792 A

95 110 12 04C 0.88

<TS 1793 A

95 110 14 02C

-0.94

<TS 1794 A

95 110 9

04H 0.91

<TS 62 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1795 A

95 118 13 VS2

-0.09

<TS 1796 A

95 124 19 VS2

-0.83

<TS 1797 A

95 124 23 VS2 0.92

<TS 1798 A

95 126 16 VS2 0.98

<TS 1799 A

95 130 11 04H 0.99

<TS 1800 A

95 130 11 VS2 0.02

<TS 1801 A

95 130 20 VS2 0.77

<TS 1802 A

95 130 6

VS2

-0.59

<TS 1803 A

95 132 11 VS4 0.98

<TS 1804 A

95 132 16 07C

-0.92

<TS 1805 A

95 132 13 06C

-0.85

<TS 1806 A

95 132 13 03C

-0.86

<TS 1807 A

95 132 19 VS2 0.96

<TS 1808 A

95 134 24 04C

-0.94

<TS 1809 A

95 134 13 03C

-0.98

<TS 1810 A

95 136 18 VS2

-0.89

<TS 1811 A

95 136 23 VS2 0.89

<TS 1812 A

95 140 21 04C 0.88

<TS 1813 A

95 142 15 02C 0.11

<TS 1814 A

95 142 16 02C 1.03

<TS 1815 A

96 25 16 02H 0.8

<TS 1816 A

96 25 12 04H 0.83

<TS 1817 A

96 25 35 VS4 0.77

<TS 1818 A

96 27 11 VS4 1.1

<TS 1819 A

96 31 14 VS6

-0.69

<TS 1820 A

96 31 10 VS4 0.82

<TS 1821 A

96 33 9

VS4

-0.92

<TS 1822 A

96 33 10 06H

-0.96

<TS 1823 A

96 37 16 VS6

-0.73

<TS 1824 A

96 39 10 VS6 0.2

<TS 1825 A

96 41 14 04C 0.86

<TS 1826 A

96 41 16 VS6 0.95

<TS 1827 A

96 41 11 VS6

-0.26

<TS 1828 A

96 59 12 07C

-0.72

<TS 1829 A

96 59 8

06C

-0.92

<TS 1830 A

96 59 16 04C

-0.94

<TS 1831 A

96 61 20 06C 0.09

<TS 1832 A

96 61 14 06H 0.9

<TS 1833 A

96 61 12 04H 0.09

<TS 63 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1834 A

96 63 23 04C 0.83

<TS 1835 A

96 65 13 05H

-0.92

<TS 1836 A

96 69 11 04H 0.92

<TS 1837 A

96 73 7

05H 0.91

<TS 1838 A

96 87 13 05H 0.91

<TS 1839 A

96 87 17 05C 0.86

<TS 1840 A

96 89 12 05H

-0.89

<TS 1841 A

96 89 10 04H 0.89

<TS 1842 A

96 91 7

04H

-0.81

<TS 1843 A

96 91 10 06H

-0.85

<TS 1844 A

96 91 10 04H

-0.13

<TS 1845 A

96 93 10 01C 0.09

<TS 1846 A

96 97 9

06C 0.87

<TS 1847 A

96 97 10 06C

-0.85

<TS 1848 A

96 99 11 04H

-0.13

<TS 1849 A

96 99 10 04H

-0.92

<TS 1850 A

96 103 13 05C 0.9

<TS 1851 A

96 105 8

07H 0.97

<TS 1852 A

96 105 17 VS6

-0.75

<TS 1853 A

96 109 18 04C 0.88

<TS 1854 A

96 111 20 05C 0.81

<TS 1855 A

96 111 17 04C 0.81

<TS 1856 A

96 111 12 04C 0.07

<TS 1857 A

96 113 8

VS6

-0.77

<TS 1858 A

96 117 13 VS6

-0.72

<TS 1859 A

96 117 9

VS6

-0.22

<TS 1860 A

96 119 11 05H 0.87

<TS 1861 A

96 121 20 VS6 1.07

<TS 1862 A

96 131 9

05C 0.85

<TS 1863 A

96 131 20 04C

-1.08

<TS 1864 A

96 131 10 03C 0.79

<TS 1865 A

96 141 15 VS4 1.02

<TS 1866 A

96 141 14 VS4

-0.9

<TS 1867 A

97 26 17 VS4 0.55

<TS 1868 A

97 26 15 VS4

-0.84

<TS 1869 A

97 28 10 VS4

-0.6

<TS 1870 A

97 28 12 VS4 0.93

<TS 1871 A

97 46 13 VS6

-0.77

<TS 1872 A

97 46 13 VS6

-0.22

<TS 64 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1873 A

97 46 9

VS4 0.9

<TS 1874 A

97 48 9

DBC 2

<TS 1875 A

97 48 16 VS6 0.81

<TS 1876 A

97 48 14 VS6

-0.86

<TS 1877 A

97 48 16 VS4 0.92

<TS 1878 A

97 48 14 VS4

-0.97

<TS 1879 A

97 50 27 VS2

-0.9

<TS 1880 A

97 50 19 VS4

-0.86

<TS 1881 A

97 50 19 VS4 0.86

<TS 1882 A

97 50 19 VS6 0.77

<TS 1883 A

97 50 12 VS2 0.9

<TS 1884 A

97 52 18 VS2 0.88

<TS 1885 A

97 52 9

VS2

-0.84

<TS 1886 A

97 52 28 VS4

-0.81

<TS 1887 A

97 52 25 VS6 0.79

<TS 1888 A

97 54 13 05C 0.9

<TS 1889 A

97 54 16 05C

-0.51

<TS 1890 A

97 58 17 07C 0.94

<TS 1891 A

97 62 18 05C

-0.96

<TS 1892 A

97 62 20 06C 0.81

<TS 1893 A

97 64 19 06C

-0.88

<TS 1894 A

97 64 10 05H 0.99

<TS 1895 A

97 68 10 05H 0.95

<TS 1896 A

97 70 12 07H 0.88

<TS 1897 A

97 80 10 01C 0.83

<TS 1898 A

97 82 13 05C 0.88

<TS 1899 A

97 90 15 VS2 0.79

<TS 1900 A

97 90 10 VS4 0.85

<TS 1901 A

97 90 13 VS2 0.02

<TS 1902 A

97 90 14 05C 0.75

<TS 1903 A

97 90 22 VS6

-0.73

<TS 1904 A

97 90 8

VS4

-0.86

<TS 1905 A

97 90 12 VS4

-0.11

<TS 1906 A

97 96 9

VS2 0.77

<TS 1907 A

97 96 11 VS2 0.18

<TS 1908 A

97 96 12 04C

-0.86

<TS 1909 A

97 100 11 VS2 0.15

<TS 1910 A

97 106 25 VS4

-0.92

<TS 1911 A

97 106 18 VS4 0.9

<TS 65 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1912 A

97 112 12 VS2 0.88

<TS 1913 A

97 112 14 VS4

-0.88

<TS 1914 A

97 112 13 VS4 0.95

<TS 1915 A

97 112 10 05C 0.9

<TS 1916 A

97 114 17 VS4

-0.9

<TS 1917 A

97 116 17 VS4

-0.89

<TS 1918 A

97 116 18 05C 0.83

<TS 1919 A

97 118 23 VS4 0.66

<TS 1920 A

97 120 15 VS2

-0.9

<TS 1921 A

97 120 29 VS2 0.94

<TS 1922 A

97 120 13 VS4 0.7

<TS 1923 A

97 124 13 VS2

-0.87

<TS 1924 A

97 124 11 VS2 0.9

<TS 1925 A

97 126 15 VS4 0.13

<TS 1926 A

97 132 11 DBH 1.88

<TS 1927 A

97 132 16 VS4 0.85

<TS 1928 A

97 132 14 04C

-0.94

<TS 1929 A

97 134 21 VS4 0.92

<TS 1930 A

97 134 12 VS4

-0.88

<TS 1931 A

97 136 14 04C

-0.97

<TS 1932 A

97 138 18 02C 0.86

<TS 1933 A

97 140 13 03C

-0.95

<TS 1934 A

98 27 20 VS2 0.69

<TS 1935 A

98 27 10 VS6

-0.82

<TS 1936 A

98 27 17 VS6 0.89

<TS 1937 A

98 35 12 05H 0.83

<TS 1938 A

98 39 11 05H 0.85

<TS 1939 A

98 45 9

05H

-0.22

<TS 1940 A

98 49 11 07C 0.86

<TS 1941 A

98 51 17 05C 0.73

<TS 1942 A

98 55 18 05H 0.93

<TS 1943 A

98 55 13 DBC

-1.75

<TS 1944 A

98 59 13 05C

-0.95

<TS 1945 A

98 63 13 05C

-0.94

<TS 1946 A

98 65 20 VS2

-0.75

<TS 1947 A

98 71 8

07C 0.09

<TS 1948 A

98 75 17 06C 0.88

<TS 1949 A

98 85 10 VS6

-0.86

<TS 1950 A

98 85 10 DBC 1.63

<TS 66 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1951 A

98 85 15 06C 0.79

<TS 1952 A

98 87 24 06C 0.85

<TS 1953 A

98 87 11 06C

-0.9

<TS 1954 A

98 95 12 03C 0.83

<TS 1955 A

98 105 22 04C 0.83

<TS 1956 A

98 105 18 05C

-0.96

<TS 1957 A

98 109 13 04H 0.91

<TS 1958 A

98 109 18 05H

-1.02

<TS 1959 A

98 109 15 07H

-0.9

<TS 1960 A

98 109 16 05C 0.86

<TS 1961 A

98 111 15 07H 0.13

<TS 1962 A

98 111 11 VS2

-0.18

<TS 1963 A

98 111 16 VS2 0.61

<TS 1964 A

98 113 12 VS2 0.61

<TS 1965 A

98 119 12 VS6 0.7

<TS 1966 A

98 125 14 VS4 0.81

<TS 1967 A

98 127 20 07H 0.81

<TS 1968 A

98 133 16 04C 0.87

<TS 1969 A

98 135 12 03C 0.11

<TS 1970 A

98 139 16 02C

-0.22

<TS 1971 A

99 26 17 VS4

-0.84

<TS 1972 A

99 26 18 VS4

-0.51

<TS 1973 A

99 28 11 VS4 0.86

<TS 1974 A

99 28 10 VS4

-0.53

<TS 1975 A

99 30 11 VS4

-0.9

<TS 1976 A

99 30 9

VS4 0.75

<TS 1977 A

99 36 13 VS4 0.86

<TS 1978 A

99 60 12 03H

-0.84

<TS 1979 A

99 70 9

06H

-0.17

<TS 1980 A

99 84 16 VS6

-0.92

<TS 1981 A

99 84 10 VS6 0.92

<TS 1982 A

99 94 16 03C 0.88

<TS 1983 A

99 96 11 07C 0.09

<TS 1984 A

99 104 16 02C

-0.92

<TS 1985 A

99 104 11 02C 0.13

<TS 1986 A

99 104 11 05C

-0.9

<TS 1987 A

99 106 13 02C

-0.94

<TS 1988 A

99 112 18 04C 0.9

<TS 1989 A

99 116 13 VS4

-0.9

<TS 67 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1990 A

99 118 9

04H 0.15

<TS 1991 A

99 136 12 VS4

-0.9

<TS 1992 A

99 136 8

VS4 0.72

<TS 1993 A

99 138 13 03H 0.86

<TS 1994 A

99 138 16 VS4 0.09

<TS 1995 A

99 138 19 VS4 0.76

<TS 1996 A

99 138 14 02C 0.07

<TS 1997 A

99 138 15 02C

-0.96

<TS 1998 A

99 138 17 03C

-0.44

<TS 1999 A

99 140 28 VS4

-0.83

<TS 2000 A

99 140 17 03C

-0.15

<TS 2001 A

99 140 16 03C

-0.97

<TS 2002 A

100 27 23 VS4

-0.88

<TS 2003 A

100 27 14 VS4

-0.2

<TS 2004 A

100 27 12 VS4 0.99

<TS 2005 A

100 29 12 04H 0.87

<TS 2006 A

100 29 14 05H 0.85

<TS 2007 A

100 29 15 06H 0.91

<TS 2008 A

100 29 11 VS2

-0.86

<TS 2009 A

100 29 19 VS2 0.91

<TS 2010 A

100 29 15 VS4 0.93

<TS 2011 A

100 29 11 VS4 0.07

<TS 2012 A

100 31 14 VS2

-0.89

<TS 2013 A

100 31 13 06H

-0.09

<TS 2014 A

100 31 10 06H

-0.89

<TS 2015 A

100 31 12 04H 0.84

<TS 2016 A

100 33 10 VS2

-0.86

<TS 2017 A

100 35 12 03H

-0.8

<TS 2018 A

100 35 8

05C 0.15

<TS 2019 A

100 41 12 06C 0.75

<TS 2020 A

100 49 12 05C 0.88

<TS 2021 A

100 51 9

06H

-0.06

<TS 2022 A

100 61 12 03H

-0.86

<TS 2023 A

100 65 11 06H

-0.91

<TS 2024 A

100 67 28 VS6

-0.95

<TS 2025 A

100 75 10 06C 0.9

<TS 2026 A

100 87 10 05C 0.86

<TS 2027 A

100 87 10 04H

-0.74

<TS 2028 A

100 89 14 03C 0.85

<TS 68 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2029 A

100 89 10 04C

-0.94

<TS 2030 A

100 89 17 VS2

-0.79

<TS 2031 A

100 99 14 05C 0.87

<TS 2032 A

100 103 14 05C

-0.97

<TS 2033 A

100 103 18 02C 0.88

<TS 2034 A

100 107 21 VS4

-0.9

<TS 2035 A

100 107 12 04C 0.9

<TS 2036 A

100 113 15 DBH 1.92

<TS 2037 A

100 115 17 05H

-0.87

<TS 2038 A

100 115 12 03C 0.83

<TS 2039 A

100 119 23 VS2

-0.79

<TS 2040 A

100 119 25 VS2 0

<TS 2041 A

100 119 14 VS4

-0.9

<TS 2042 A

100 119 15 VS6 0.94

<TS 2043 A

100 119 10 VS2 0.75

<TS 2044 A

100 131 10 05C 0.83

<TS 2045 A

100 133 14 DBH 1.99

<TS 2046 A

100 137 13 VS4

-0.9

<TS 2047 A

100 137 12 VS4 0.83

<TS 2048 A

100 137 18 05C

-0.92

<TS 2049 A

100 137 13 04C 0.83

<TS 2050 A

100 137 34 03C

-0.6

<TS 2051 A

100 139 19 VS4

-0.9

<TS 2052 A

100 139 15 03C

-0.13

<TS 2053 A

101 28 10 03H 0.93

<TS 2054 A

101 28 17 VS4

-0.83

<TS 2055 A

101 28 20 VS4 0.7

<TS 2056 A

101 30 17 04H

-0.17

<TS 2057 A

101 30 13 VS4

-0.92

<TS 2058 A

101 30 10 VS4 0.73

<TS 2059 A

101 36 10 03H 0.86

<TS 2060 A

101 40 9

05H 0.11

<TS 2061 A

101 44 13 VS2 0.81

<TS 2062 A

101 48 14 DBC 1.78

<TS 2063 A

101 56 13 06C

-0.99

<TS 2064 A

101 68 12 06H 0.83

<TS 2065 A

101 70 12 07C

-0.22

<TS 2066 A

101 70 14 05H 0.87

<TS 2067 A

101 78 8

07H

-0.83

<TS 69 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2068 A

101 78 7

07H 0.2

<TS 2069 A

101 86 10 07C 0.77

<TS 2070 A

101 102 12 04C 0.09

<TS 2071 A

101 104 9

05C

-0.11

<TS 2072 A

101 106 13 04C 0.86

<TS 2073 A

101 108 12 VS2 0.77

<TS 2074 A

101 110 8

VS2 0.18

<TS 2075 A

101 110 13 VS2 0.79

<TS 2076 A

101 112 13 06H 0.86

<TS 2077 A

101 114 10 VS2

-0.92

<TS 2078 A

101 114 14 07C

-0.9

<TS 2079 A

101 114 14 03C

-0.83

<TS 2080 A

101 118 15 DBH 1.64

<TS 2081 A

101 120 11 03C 0.87

<TS 2082 A

101 124 16 07C 0.85

<TS 2083 A

101 128 13 04H

-0.9

<TS 2084 A

101 132 10 03C 0.88

<TS 2085 A

101 136 13 03C

-0.87

<TS 2086 A

101 136 14 02C 0

<TS 2087 A

101 138 20 VS4 0.85

<TS 2088 A

101 138 9

07C 0.79

<TS 2089 A

102 29 20 VS4

-0.95

<TS 2090 A

102 29 12 VS4

-0.11

<TS 2091 A

102 29 13 04C

-0.9

<TS 2092 A

102 31 8

02C 0.86

<TS 2093 A

102 31 10 07C 0.75

<TS 2094 A

102 31 9

03H 0.88

<TS 2095 A

102 49 9

06H 0.88

<TS 2096 A

102 55 12 03C

-0.9

<TS 2097 A

102 67 10 07C 0.04

<TS 2098 A

102 67 13 07H 0.9

<TS 2099 A

102 73 13 07C

-0.9

<TS 2100 A

102 75 11 VS2

-0.94

<TS 2101 A

102 83 10 01C 0.81

<TS 2102 A

102 85 8

05C 0.77

<TS 2103 A

102 89 8

03H 0.91

<TS 2104 A

102 89 17 04C 0.81

<TS 2105 A

102 91 11 04C

-0.88

<TS 2106 A

102 95 14 02C

-0.85

<TS 70 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2107 A

102 95 14 05C

-0.15

<TS 2108 A

102 105 9

02C 0.09

<TS 2109 A

102 105 8

03C 0.07

<TS 2110 A

102 105 13 03C

-0.9

<TS 2111 A

102 105 16 05C 0.81

<TS 2112 A

102 107 12 VS2 0.66

<TS 2113 A

102 113 12 05C 0.83

<TS 2114 A

102 115 14 VS2

-0.81

<TS 2115 A

102 115 20 VS2

-0.07

<TS 2116 A

102 117 24 03H 0.88

<TS 2117 A

102 121 25 VS4

-0.92

<TS 2118 A

102 133 13 03C

-0.93

<TS 2119 A

102 135 15 04C 0.81

<TS 2120 A

102 135 15 03C

-0.2

<TS 2121 A

102 135 7

02C 0.74

<TS 2122 A

102 137 14 04C

-0.94

<TS 2123 A

103 30 11 05H

-0.89

<TS 2124 A

103 30 10 07H

-0.93

<TS 2125 A

103 30 17 VS4 0.62

<TS 2126 A

103 30 7

05C 0.84

<TS 2127 A

103 30 8

06H

-1.03

<TS 2128 A

103 30 10 VS4

-0.11

<TS 2129 A

103 32 12 02C

-0.18

<TS 2130 A

103 32 9

03C 0.07

<TS 2131 A

103 32 18 VS4

-0.91

<TS 2132 A

103 32 7

VS4 0.58

<TS 2133 A

103 36 7

VS2

-0.91

<TS 2134 A

103 36 9

VS2 0.95

<TS 2135 A

103 36 10 05C

-0.91

<TS 2136 A

103 54 13 05H 0.95

<TS 2137 A

103 54 10 04H

-0.97

<TS 2138 A

103 82 15 06H 0.92

<TS 2139 A

103 82 8

06H

-0.11

<TS 2140 A

103 82 17 05H

-0.06

<TS 2141 A

103 82 11 05H

-0.85

<TS 2142 A

103 84 10 07H 0.92

<TS 2143 A

103 86 19 VS2 0.15

<TS 2144 A

103 86 15 VS2 0.66

<TS 2145 A

103 92 9

04C

-0.88

<TS 71 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2146 A

103 92 11 04C 0.85

<TS 2147 A

103 92 16 05C 0.85

<TS 2148 A

103 96 13 05C 0.9

<TS 2149 A

103 100 9

05C

-0.86

<TS 2150 A

103 102 11 03C

-0.15

<TS 2151 A

103 108 17 07C

-0.15

<TS 2152 A

103 118 13 04C

-0.99

<TS 2153 A

103 122 10 07C 0.9

<TS 2154 A

103 122 18 DBC 1.69

<TS 2155 A

103 134 12 04C 0.92

<TS 2156 A

103 134 14 04C 0.07

<TS 2157 A

103 136 13 02C 0.87

<TS 2158 A

104 31 20 VS4

-0.93

<TS 2159 A

104 31 21 VS4 0.84

<TS 2160 A

104 33 12 03C

-0.86

<TS 2161 A

104 33 11 04C

-0.83

<TS 2162 A

104 61 14 06C 0.9

<TS 2163 A

104 63 12 05C

-0.9

<TS 2164 A

104 63 14 07C

-0.92

<TS 2165 A

104 69 11 07H

-0.94

<TS 2166 A

104 71 12 DBH 1.99

<TS 2167 A

104 77 11 06C 0.88

<TS 2168 A

104 85 13 VS2

-0.88

<TS 2169 A

104 85 18 04C

-0.94

<TS 2170 A

104 85 12 04C 0.79

<TS 2171 A

104 87 11 04C

-0.2

<TS 2172 A

104 87 22 04C

-0.9

<TS 2173 A

104 89 15 02C

-0.9

<TS 2174 A

104 93 12 06H 0.9

<TS 2175 A

104 95 17 VS2

-0.77

<TS 2176 A

104 97 10 03C 0

<TS 2177 A

104 97 12 03C 0.89

<TS 2178 A

104 97 20 04C

-0.94

<TS 2179 A

104 99 15 06C 0.88

<TS 2180 A

104 103 13 05C 0.92

<TS 2181 A

104 103 7

DBC

-1.77

<TS 2182 A

104 109 16 VS6

-0.66

<TS 2183 A

104 121 13 07C 0.85

<TS 2184 A

104 121 16 06C 0.85

<TS 72 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2185 A

104 123 11 03C

-0.83

<TS 2186 A

104 123 14 04C 0.94

<TS 2187 A

104 133 13 05C

-0.15

<TS 2188 A

104 135 27 03C 0.88

<TS 2189 A

105 30 23 VS4

-0.58

<TS 2190 A

105 32 14 01C 0.09

<TS 2191 A

105 32 12 04H

-0.86

<TS 2192 A

105 90 15 05C 0.84

<TS 2193 A

105 92 12 07C

-0.9

<TS 2194 A

105 112 16 05H 0.95

<TS 2195 A

105 112 8

06H

-0.04

<TS 2196 A

105 120 11 04C 0.9

<TS 2197 A

105 120 12 03C

-0.96

<TS 2198 A

105 122 13 06C 0.85

<TS 2199 A

105 132 20 03C 0.85

<TS 2200 A

105 136 15 VS4

-0.9

<TS 2201 A

105 136 13 VS4 0.96

<TS 2202 A

106 31 12 01C

-0.9

<TS 2203 A

106 31 13 03C 0.87

<TS 2204 A

106 31 19 04C 0.77

<TS 2205 A

106 31 28 VS6 0.84

<TS 2206 A

106 31 14 VS6 0.29

<TS 2207 A

106 31 32 VS6

-0.86

<TS 2208 A

106 31 12 VS4 0.95

<TS 2209 A

106 31 8

VS2 0.11

<TS 2210 A

106 33 13 VS4

-1.06

<TS 2211 A

106 33 18 VS4

-0.75

<TS 2212 A

106 33 12 04C

-0.94

<TS 2213 A

106 35 18 03C 0.95

<TS 2214 A

106 35 15 03C 0.09

<TS 2215 A

106 43 10 07H

-0.95

<TS 2216 A

106 45 9

05H

-0.15

<TS 2217 A

106 47 11 DBC 1.63

<TS 2218 A

106 47 11 04C 0.09

<TS 2219 A

106 47 15 04C 0.84

<TS 2220 A

106 57 18 07H 0.92

<TS 2221 A

106 59 24 VS4

-1.15

<TS 2222 A

106 59 35 VS4 0.84

<TS 2223 A

106 59 18 VS6

-0.71

<TS 73 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2224 A

106 59 13 VS2

-0.88

<TS 2225 A

106 59 10 DBH 1.61

<TS 2226 A

106 63 13 VS4

-1.03

<TS 2227 A

106 63 14 VS4 0.33

<TS 2228 A

106 67 20 VS6 0.39

<TS 2229 A

106 67 12 VS4

-0.7

<TS 2230 A

106 69 12 07C

-0.13

<TS 2231 A

106 69 15 VS2 0.24

<TS 2232 A

106 69 11 VS6 0.94

<TS 2233 A

106 69 12 VS4

-1.19

<TS 2234 A

106 95 12 DBH

-1.69

<TS 2235 A

106 101 17 04H 0.91

<TS 2236 A

106 101 9

06C 0.09

<TS 2237 A

106 111 15 DBC 1.6

<TS 2238 A

106 117 14 VS2

-0.26

<TS 2239 A

106 117 17 06C

-0.92

<TS 2240 A

106 117 8

04H 0.64

<TS 2241 A

106 119 14 VS4 1.03

<TS 2242 A

106 119 9

04C

-0.88

<TS 2243 A

106 119 8

VS4

-1.09

<TS 2244 A

106 121 17 04C 0.88

<TS 2245 A

106 121 9

04C 0.13

<TS 2246 A

106 121 15 05C 0.11

<TS 2247 A

106 125 9

06C 0.86

<TS 2248 A

106 131 11 04H

-0.88

<TS 2249 A

106 131 20 03C

-0.53

<TS 2250 A

106 133 20 DBC 1.64

<TS 2251 A

106 133 12 03C 0.85

<TS 2252 A

106 135 9

01H 0.08

<TS 2253 A

106 135 24 VS4

-0.81

<TS 2254 A

106 135 13 03C

-0.83

<TS 2255 A

107 32 13 03C 0.98

<TS 2256 A

107 32 13 04C

-0.24

<TS 2257 A

107 32 5

04C

-1

<TS 2258 A

107 32 11 VS4

-0.29

<TS 2259 A

107 32 33 VS4

-0.8

<TS 2260 A

107 34 9

VS4 0.88

<TS 2261 A

107 34 10 01H 0.86

<TS 2262 A

107 36 10 03C 0.84

<TS 74 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*

Percent No SG Row Column in Depth Location Elevation TS 2263 A

107 40 9

VS2

-0.92

<TS 2264 A

107 44 13 05H

-0.95

<TS 2265 A

107 44 14 05H

-0.17

<TS 2266 A

107 44 13 VS2 0.79

<TS 2267 A

107 44 8

VS4 0.88

<TS 2268 A

107 62 13 VS4 0.77

<TS 2269 A

107 84 11 05C

-0.87

<TS 2270 A

107 92 14 05C 0.83

<TS 2271 A

107 94 10 04C

-0.94

<TS 2272 A

107 98 9

04C

-0.11

<TS 2273 A

107 98 8

03C

-0.07

<TS 2274 A

107 114 9

03C 0.11

<TS 2275 A

107 118 10 04C

-0.92

<TS 2276 A

107 120 13 DBH 1.89

<TS 2277 A

107 122 11 03C

-0.15

<TS 2278 A

107 124 15 03C

-0.9

<TS 2279 A

107 124 9

VS2

-0.84

<TS 2280 A

107 124 15 VS2

-0.09

<TS 2281 A

107 124 11 VS2 0.66

<TS 2282 A

107 128 15 04C

-1.01

<TS 2283 A

107 130 21 VS2

-0.72

<TS 2284 A

107 130 11 VS2 0.9

<TS 2285 A

107 130 11 03C

-0.88

<TS 2286 A

107 134 17 03H 0.82

<TS 2287 A

107 134 24 VS4

-0.99

<TS 2288 A

107 134 17 VS4 0.79

<TS 2289 A

107 134 24 02C

-0.94

<TS 2290 A

107 134 11 03C

-0.95

<TS 2291 A

108 33 24 VS4 0.95

<TS 2292 A

108 33 29 VS4

-0.88

<TS 2293 A

108 35 12 VS4

-0.95

<TS 2294 A

108 35 10 VS4 0.91

<TS 2295 A

108 35 18 01C 0.86

<TS 2296 A

108 35 27 01C 0.09

<TS 2297 A

108 39 9

04H 0.95

<TS 2298 A

108 41 16 VS4 0.95

<TS 2299 A

108 63 20 VS2 0.83

<TS 2300 A

108 63 11 VS2 0.2

<TS 2301 A

108 65 18 DBH 1.93

<TS 75 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2302 A

108 67 10 06C

-0.99

<TS 2303 A

108 69 13 07C 0.83

<TS 2304 A

108 87 11 05C 0.84

<TS 2305 A

108 89 12 06C

-0.94

<TS 2306 A

108 93 13 06C 0.37

<TS 2307 A

108 95 11 03C 0.84

<TS 2308 A

108 99 10 DBH 1.96

<TS 2309 A

108 115 15 05H 0.95

<TS 2310 A

108 117 17 05C 0.85

<TS 2311 A

108 119 12 03C 0.44

<TS 2312 A

108 123 16 VS2

-0.96

<TS 2313 A

108 131 14 02C

-0.87

<TS 2314 A

108 133 12 04C 0.82

<TS 2315 A

108 133 16 04C

-0.9

<TS 2316 A

109 34 9

01C 0.86

<TS 2317 A

109 34 31 VS4 0.64

<TS 2318 A

109 34 10 VS4

-0.91

<TS 2319 A

109 34 12 05H

-0.82

<TS 2320 A

109 34 12 04H

-0.91

<TS 2321 A

109 34 10 01H 0.94

<TS 2322 A

109 42 8

03H 0.92

<TS 2323 A

109 62 15 06C 0.89

<TS 2324 A

109 90 10 07C

-0.88

<TS 2325 A

109 90 11 07C

-0.09

<TS 2326 A

109 98 30 VS2

-0.79

<TS 2327 A

109 114 19 06C 0.83

<TS 2328 A

109 114 12 03C 0.99

<TS 2329 A

109 116 11 04H

-0.89

<TS 2330 A

109 118 15 04C

-0.94

<TS 2331 A

109 120 21 03C

-0.13

<TS 2332 A

109 124 9

02C 0.85

<TS 2333 A

109 124 11 08C

-1.12

<TS 2334 A

109 128 10 04C 0.87

<TS 2335 A

109 132 20 04C 0.85

<TS 2336 A

110 35 10 VS4 0.9

<TS 2337 A

110 35 15 01H 0.92

<TS 2338 A

110 39 15 VS2 0.86

<TS 2339 A

110 47 11 05C 0.9

<TS 2340 A

110 79 11 06C

-0.18

<TS 76 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2341 A

110 83 16 06C 0.9

<TS 2342 A

110 91 13 04C

-0.9

<TS 2343 A

110 109 7

DBC

-0.24

<TS 2344 A

110 109 15 05C 1.16

<TS 2345 A

110 109 10 04C 0.9

<TS 2346 A

110 115 12 08H 0.92

<TS 2347 A

110 115 9

04C 0.9

<TS 2348 A

110 123 21 08H

-1.05

<TS 2349 A

110 125 22 VS2 0.9

<TS 2350 A

110 131 15 01H 0.11

<TS 2351 A

110 131 31 DBH

-1.73

<TS 2352 A

110 131 15 04C

-0.9

<TS 2353 A

110 131 19 03C 0.81

<TS 2354 A

110 131 11 05C

-0.02

<TS 2355 A

111 44 16 06C

-0.15

<TS 2356 A

111 50 9

04H

-0.87

<TS 2357 A

111 62 19 VS2

-0.82

<TS 2358 A

111 82 8

02H 0.85

<TS 2359 A

111 86 11 02C 0.9

<TS 2360 A

111 100 11 05C 0.85

<TS 2361 A

111 104 11 04C

-0.18

<TS 2362 A

111 110 17 VS4

-0.9

<TS 2363 A

111 116 14 03C 0.83

<TS 2364 A

111 116 13 03H 0.91

<TS 2365 A

111 126 14 04C 0.85

<TS 2366 A

111 126 8

04C 0.13

<TS 2367 A

111 128 11 VS4 0.96

<TS 2368 A

111 128 12 03C 0.86

<TS 2369 A

111 128 20 03C

-0.87

<TS 2370 A

111 130 19 04C

-0.2

<TS 2371 A

111 130 12 03H

-0.92

<TS 2372 A

112 37 10 DBH

-1.52

<TS 2373 A

112 37 20 02C

-0.92

<TS 2374 A

112 39 9

VS6 0.93

<TS 2375 A

112 41 12 VS6

-0.86

<TS 2376 A

112 41 20 VS4

-0.95

<TS 2377 A

112 59 21 VS4

-0.79

<TS 2378 A

112 59 24 VS4 0.02

<TS 2379 A

112 59 33 VS6 0.94

<TS 77 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2380 A

112 65 12 VS4 0.74

<TS 2381 A

112 65 14 VS4

-0.79

<TS 2382 A

112 69 12 VS2 0.81

<TS 2383 A

112 69 16 VS2

-0.02

<TS 2384 A

112 89 10 04C

-0.9

<TS 2385 A

112 89 15 VS4

-0.87

<TS 2386 A

112 103 12 VS2 0.9

<TS 2387 A

112 103 12 04H 0.89

<TS 2388 A

112 103 14 VS2

-0.92

<TS 2389 A

112 115 13 04C

-0.89

<TS 2390 A

112 119 14 04H 0.92

<TS 2391 A

112 121 17 VS2

-0.81

<TS 2392 A

112 125 11 05C

-0.89

<TS 2393 A

112 125 12 04C 0.89

<TS 2394 A

112 127 16 05C

-0.96

<TS 2395 A

113 36 11 01H 0.9

<TS 2396 A

113 36 9

01H

-0.09

<TS 2397 A

113 36 18 VS4

-0.79

<TS 2398 A

113 38 14 02C 0.86

<TS 2399 A

113 38 12 01C

-0.95

<TS 2400 A

113 42 14 VS4 0.95

<TS 2401 A

113 42 15 VS4

-0.88

<TS 2402 A

113 64 12 07H 0.83

<TS 2403 A

113 68 15 VS2

-0.77

<TS 2404 A

113 68 13 VS6 1.05

<TS 2405 A

113 68 11 VS4

-1.05

<TS 2406 A

113 76 16 VS6 0.85

<TS 2407 A

113 90 14 03C

-0.92

<TS 2408 A

113 90 10 VS6

-0.74

<TS 2409 A

113 90 12 VS4

-0.59

<TS 2410 A

113 118 15 04C 0.13

<TS 2411 A

113 128 12 03H 0.94

<TS 2412 A

113 128 17 04H

-0.87

<TS 2413 A

113 130 22 VS4

-0.83

<TS 2414 A

113 130 22 VS4

-0.48

<TS 2415 A

114 45 8

VS2 0.53

<TS 2416 A

114 47 11 05H 0.91

<TS 2417 A

114 51 11 04C 0.88

<TS 2418 A

114 53 9

04H 0.91

<TS 78 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2419 A

114 53 9

04C 0.95

<TS 2420 A

114 65 14 VS4 0.83

<TS 2421 A

114 75 11 06H 0.97

<TS 2422 A

114 79 8

05H 0.91

<TS 2423 A

114 119 14 07C 0.76

<TS 2424 A

114 119 16 03C 0.76

<TS 2425 A

114 121 14 04C 0.81

<TS 2426 A

114 121 11 03C

-0.91

<TS 2427 A

114 123 12 04C

-0.94

<TS 2428 A

114 123 20 03C

-0.89

<TS 2429 A

114 129 8

03H 1.01

<TS 2430 A

114 129 12 08H

-0.97

<TS 2431 A

114 129 25 VS4

-0.91

<TS 2432 A

114 129 10 VS4 0.97

<TS 2433 A

115 38 15 02C 0.09

<TS 2434 A

115 38 10 02C

-0.86

<TS 2435 A

115 38 12 DBC 1.31

<TS 2436 A

115 38 11 VS4 0.51

<TS 2437 A

115 38 10 VS4 0.89

<TS 2438 A

115 46 16 VS4

-0.88

<TS 2439 A

115 50 10 VS4

-0.77

<TS 2440 A

115 78 17 06H

-0.87

<TS 2441 A

115 82 13 05H 0.82

<TS 2442 A

115 82 8

05H

-0.04

<TS 2443 A

115 90 9

VS2

-0.79

<TS 2444 A

115 90 39 VS4

-0.88

<TS 2445 A

115 92 27 VS1 0.79

<TS 2446 A

115 124 12 05C 1.01

<TS 2447 A

115 124 17 04C

-0.95

<TS 2448 A

115 124 10 03C 0.88

<TS 2449 A

115 128 11 05H 0.8

<TS 2450 A

115 128 9

VS4

-0.64

<TS 2451 A

116 39 30 02C

-0.86

<TS 2452 A

116 39 13 01C

-0.49

<TS 2453 A

116 39 15 VS6

-0.57

<TS 2454 A

116 45 12 VS7 0.75

<TS 2455 A

116 45 15 02H 0.82

<TS 2456 A

116 51 11 05H

-0.19

<TS 2457 A

116 51 17 07H 0.88

<TS 79 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2458 A

116 53 12 05C 0.9

<TS 2459 A

116 55 12 05H

-0.82

<TS 2460 A

116 61 11 VS4 0.83

<TS 2461 A

116 63 14 VS6

-0.79

<TS 2462 A

116 71 11 VS4 0.94

<TS 2463 A

116 81 12 05H 0.89

<TS 2464 A

116 81 14 VS6

-0.85

<TS 2465 A

116 81 10 06C 0.87

<TS 2466 A

116 81 11 06C

-0.92

<TS 2467 A

116 95 13 07C

-0.92

<TS 2468 A

116 95 10 06C 0.81

<TS 2469 A

116 105 23 VS4

-1.05

<TS 2470 A

116 111 15 05C 0.04

<TS 2471 A

116 119 21 03C 0.81

<TS 2472 A

116 121 11 03C

-0.88

<TS 2473 A

116 121 22 04C 0.82

<TS 2474 A

116 121 12 VS7 0.96

<TS 2475 A

116 121 7

04C

-0.09

<TS 2476 A

116 123 15 06C 0.04

<TS 2477 A

117 40 21 VS4

-0.95

<TS 2478 A

117 40 24 02C 0.88

<TS 2479 A

117 40 10 02C

-0.15

<TS 2480 A

117 42 36 01C

-0.93

<TS 2481 A

117 42 12 02C 0.81

<TS 2482 A

117 44 10 02C 0.86

<TS 2483 A

117 50 12 VS4

-0.88

<TS 2484 A

117 58 15 06C 0.83

<TS 2485 A

117 70 11 06C 0.75

<TS 2486 A

117 72 11 07H 0.46

<TS 2487 A

117 76 10 07H 0.13

<TS 2488 A

117 78 11 04H 0.88

<TS 2489 A

117 82 13 05H

-0.97

<TS 2490 A

117 90 12 VS2 0.83

<TS 2491 A

117 94 9

03C 0.88

<TS 2492 A

117 110 13 03C 0.86

<TS 2493 A

117 114 14 03C

-0.88

<TS 2494 A

117 120 12 03H 0.84

<TS 2495 A

117 120 13 02C 0.83

<TS 2496 A

117 122 14 VS4

-0.02

<TS 80 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2497 A

117 122 12 04C

-0.2

<TS 2498 A

118 41 9

01H 0.89

<TS 2499 A

118 41 16 VS4

-0.92

<TS 2500 A

118 41 26 02C 0

<TS 2501 A

118 43 35 01C

-0.91

<TS 2502 A

118 43 11 02C

-0.94

<TS 2503 A

118 43 8

02C 0.77

<TS 2504 A

118 43 10 06H

-0.91

<TS 2505 A

118 43 12 03H 0.88

<TS 2506 A

118 45 10 VS6 0.99

<TS 2507 A

118 47 14 02H 0.73

<TS 2508 A

118 51 13 06C 0.84

<TS 2509 A

118 53 10 VS6

-0.86

<TS 2510 A

118 63 16 VS4

-0.94

<TS 2511 A

118 63 9

VS4 0.92

<TS 2512 A

118 97 13 VS2

-0.99

<TS 2513 A

118 99 17 VS2 0.83

<TS 2514 A

118 101 11 04H

-0.13

<TS 2515 A

118 101 12 VS4 0.88

<TS 2516 A

118 105 15 04C 0.88

<TS 2517 A

118 125 21 VS7

-0.72

<TS 2518 A

119 42 12 VS4

-0.88

<TS 2519 A

119 44 11 02H 0.9

<TS 2520 A

119 52 26 06C 0.84

<TS 2521 A

119 60 15 VS4

-0.88

<TS 2522 A

119 60 15 VS4 0.93

<TS 2523 A

119 76 9

06C 0.83

<TS 2524 A

119 82 11 VS4 0.18

<TS 2525 A

119 98 6

07H 0.9

<TS 2526 A

119 110 21 04C

-0.86

<TS 2527 A

119 122 15 06H 0.92

<TS 2528 A

119 122 13 03C 0.77

<TS 2529 A

119 124 10 VS4

-0.86

<TS 2530 A

119 124 7

VS4 0.61

<TS 2531 A

120 45 11 02H 0.88

<TS 2532 A

120 75 12 VS4 0.98

<TS 2533 A

120 75 14 08C

-0.94

<TS 2534 A

120 77 8

07C 0.09

<TS 2535 A

120 81 10 VS4 1.07

<TS 81 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2536 A

120 81 18 07C 0.85

<TS 2537 A

120 81 17 07C 0.07

<TS 2538 A

120 81 13 06C 0.83

<TS 2539 A

120 89 14 06C

-0.88

<TS 2540 A

120 93 14 06C 0.81

<TS 2541 A

120 111 12 04C 0.07

<TS 2542 A

120 111 11 03C

-0.94

<TS 2543 A

120 115 14 04C 0.83

<TS 2544 A

120 115 14 05C

-0.89

<TS 2545 A

120 117 9

04C 0.75

<TS 2546 A

120 119 20 03C 0.83

<TS 2547 A

120 121 21 05C 0.81

<TS 2548 A

120 123 18 01H

-0.13

<TS 2549 A

121 44 18 VS4

-0.02

<TS 2550 A

121 44 9

VS4 0.66

<TS 2551 A

121 44 16 01C

-0.95

<TS 2552 A

121 44 10 VS7 0.9

<TS 2553 A

121 50 14 06C 0.79

<TS 2554 A

121 64 11 07H 0.86

<TS 2555 A

121 76 12 VS6 0.83

<TS 2556 A

121 88 13 07C

-0.92

<TS 2557 A

121 104 9

VS4 0.61

<TS 2558 A

121 104 11 VS6

-0.85

<TS 2559 A

121 104 11 VS6

-0.07

<TS 2560 A

121 106 8

02C 0.83

<TS 2561 A

121 112 22 VS7

-0.73

<TS 2562 A

121 116 15 04C

-0.88

<TS 2563 A

121 116 23 03C 0.84

<TS 2564 A

121 118 29 VS4

-0.73

<TS 2565 A

121 118 16 VS4 0.04

<TS 2566 A

121 118 19 VS4 0.77

<TS 2567 A

121 118 9

VS6 0.94

<TS 2568 A

121 118 8

VS7

-1.05

<TS 2569 A

121 118 25 03C 0.92

<TS 2570 A

121 120 14 05H 0.82

<TS 2571 A

121 120 15 06H 0.85

<TS 2572 A

122 45 11 01C 0.91

<TS 2573 A

122 53 12 06H 0.77

<TS 2574 A

122 63 15 05H 0.95

<TS 82 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2575 A

122 63 10 05H 0

<TS 2576 A

122 65 9

DBH 1.49

<TS 2577 A

122 65 12 VS6 0.83

<TS 2578 A

122 81 20 VS4 1.1

<TS 2579 A

122 105 8

04C 0.88

<TS 2580 A

122 105 9

04C 0.09

<TS 2581 A

122 111 14 05C

-1.01

<TS 2582 A

122 111 11 02C

-0.15

<TS 2583 A

122 117 10 VS2 0.02

<TS 2584 A

122 117 17 VS2

-0.83

<TS 2585 A

122 117 13 VS1 0.85

<TS 2586 A

123 48 9

05C 0.86

<TS 2587 A

123 52 11 06H

-0.91

<TS 2588 A

123 110 10 VS2 0.94

<TS 2589 A

123 110 7

06C

-0.07

<TS 2590 A

123 112 14 03C 0.9

<TS 2591 A

123 114 17 04C

-0.18

<TS 2592 A

123 120 15 02H 0.79

<TS 2593 A

123 120 9

04H

-0.84

<TS 2594 A

123 120 10 04H 0.88

<TS 2595 A

123 120 11 VS4

-0.79

<TS 2596 A

124 49 12 01H 0.91

<TS 2597 A

124 51 14 03H 0.86

<TS 2598 A

124 57 10 05C 0.9

<TS 2599 A

124 117 13 06C

-0.2

<TS 2600 A

124 117 13 03C 0

<TS 2601 A

124 119 9

02C

-0.9

<TS 2602 A

124 119 11 VS4

-0.9

<TS 2603 A

125 48 21 VS4

-0.93

<TS 2604 A

125 88 19 08H 0.89

<TS 2605 A

125 110 18 03C 0.83

<TS 2606 A

125 112 16 07H

-0.26

<TS 2607 A

125 112 16 VS6

-0.9

<TS 2608 A

125 112 11 04C

-0.92

<TS 2609 A

125 112 16 03C 0.13

<TS 2610 A

125 112 11 02C 0.88

<TS 2611 A

125 114 13 03H

-0.19

<TS 2612 A

125 114 11 02C 0.84

<TS 2613 A

125 118 12 VS4

-0.83

<TS 83 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear*

Percent No SG Row Column in Depth Location Elevation TS 2614 A

126 51 10 01H 0.09

<TS 2615 A

126 51 20 03H 0.85

<TS 2616 A

126 51 9

VS2 0.86

<TS 2617 A

126 61 7

07H

-0.99

<TS 2618 A

126 63 11 07H 0.85

<TS 2619 A

126 69 14 VS4

-0.9

<TS 2620 A

126 69 34 VS4 0.88

<TS 2621 A

126 69 10 08H

-0.88

<TS 2622 A

126 73 12 08C

-0.9

<TS 2623 A

126 77 13 VS1

-0.89

<TS 2624 A

126 77 15 VS1 0.91

<TS 2625 A

126 83 10 07H 0.09

<TS 2626 A

126 85 12 06C 0.89

<TS 2627 A

126 103 10 VS1 0.92

<TS 2628 A

126 103 31 VS4

-0.99

<TS 2629 A

126 109 10 05C 0.79

<TS 2630 A

126 109 6

05C 0.07

<TS 2631 A

126 109 9

03C 0.9

<TS 2632 A

126 109 7

03C 0.04

<TS 2633 A

126 111 12 VS6

-0.9

<TS 2634 A

126 111 15 VS7 0.92

<TS 2635 A

126 111 10 04C

-0.15

<TS 2636 A

126 111 13 03C

-0.92

<TS 2637 A

126 111 10 02C

-0.88

<TS 2638 A

126 115 9

05H 0.91

<TS 2639 A

126 115 14 VS6

-0.92

<TS 2640 A

126 115 16 04C 0.9

<TS 2641 A

126 115 7

03C 0.86

<TS 2642 A

126 115 16 02C

-0.88

<TS 2643 A

126 115 13 02C 0.29

<TS 2644 A

127 52 9

03C

-0.13

<TS 2645 A

127 52 9

02C

-0.94

<TS 2646 A

127 52 9

01C 0.96

<TS 2647 A

127 56 11 DBH 1.58

<TS 2648 A

127 56 15 VS1

-0.72

<TS 2649 A

127 56 10 VS1 0.77

<TS 2650 A

127 56 11 VS4 0.9

<TS 2651 A

127 56 16 VS6 0.88

<TS 2652 A

127 72 18 VS6

-0.37

<TS 84 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear Percent No SG Row Column in Depth Location Elevation TS 2653 A

127 76 13 VS1

-0.92

<TS 2654 A

127 76 9

VS4 1.05

<TS 2655 A

127 80 14 VS7 0.76

<TS 2656 A

127 80 17 06C 0.81

<TS 2657 A

127 90 11 08H

-0.88

<TS 2658 A

127 98 10 04C

-0.9

<TS 2659 A

127 106 13 VS4

-0.57

<TS 2660 A

127 108 21 05C

-0.9

<TS 2661 A

127 110 29 VS2

-0.88

<TS 2662 A

127 110 16 VS2 0.94

<TS 2663 A

127 110 14 VS4

-0.92

<TS 2664 A

127 110 15 VS4

-0.04

<TS 2665 A

127 112 25 03C

-0.9

<TS 2666 A

127 112 12 02C

-0.99

<TS 2667 A

127 114 18 VS4

-0.11

<TS 2668 A

127 114 16 05C

-0.09

<TS 2669 A

128 53 19 02H

-0.95

<TS 2670 A

128 55 7

VS1

-0.86

<TS 2671 A

128 55 11 VS7 1.19

<TS 2672 A

128 55 11 VS6 0.04

<TS 2673 A

128 69 15 08H 0.82

<TS 2674 A

128 71 18 VS1

-1.01

<TS 2675 A

128 71 31 VS1 0.92

<TS 2676 A

128 71 15 VS2 0.07

<TS 2677 A

128 77 16 07C 0.9

<TS 2678 A

128 85 14 DBH 1.84

<TS 2679 A

128 91 13 08C 0.85

<TS 2680 A

128 93 13 VS6

-0.73

<TS 2681 A

128 101 14 VS2

-0.85

<TS 2682 A

128 101 7

VS2 0.96

<TS 2683 A

128 103 13 VS2 0.85

<TS 2684 A

128 107 12 03C 0.83

<TS 2685 A

128 107 13 02C 0.86

<TS 2686 A

128 111 15 05C 0.83

<TS 2687 A

128 113 12 05C

-0.94

<TS 2688 A

129 54 25 02C

-0.92

<TS 2689 A

129 56 18 02H 0.99

<TS 2690 A

129 58 31 02H 0.84

<TS 2691 A

129 58 14 07H

-0.96

<TS 85 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2692 A

129 58 13 VS2

-0.79

<TS 2693 A

129 64 12 06C 0.88

<TS 2694 A

129 74 14 VS1

-0.92

<TS 2695 A

129 84 10 VS4 0.64

<TS 2696 A

129 86 10 DBH 1.89

<TS 2697 A

129 92 13 VS4

-0.88

<TS 2698 A

129 92 8

VS4 0.99

<TS 2699 A

129 94 12 VS4 0.59

<TS 2700 A

129 110 17 04C 0.09

<TS 2701 A

129 110 24 02C 0.86

<TS 2702 A

129 112 13 VS2

-0.83

<TS 2703 A

129 112 10 VS1

-0.9

<TS 2704 A

130 55 11 02H 0.92

<TS 2705 A

130 57 10 02H 0.9

<TS 2706 A

130 57 20 08H 0.77

<TS 2707 A

130 71 20 VS4

-0.92

<TS 2708 A

130 73 18 VS7 0.75

<TS 2709 A

130 73 11 VS6 0.95

<TS 2710 A

130 89 12 DBC

-1.99

<TS 2711 A

130 93 11 DBH 1.97

<TS 2712 A

130 95 23 VS4

-1.01

<TS 2713 A

130 99 24 03C

-0.18

<TS 2714 A

130 99 9

03C

-0.83

<TS 2715 A

130 107 13 03C

-0.29

<TS 2716 A

130 107 14 02C 0.92

<TS 2717 A

131 58 12 02H 0.86

<TS 2718 A

131 70 10 DBC 1.92

<TS 2719 A

131 76 12 06C 0.86

<TS 2720 A

131 86 12 08H 0.89

<TS 2721 A

131 94 11 08H

-1.01

<TS 2722 A

131 94 15 08H 0.97

<TS 2723 A

131 94 16 VS1 0.9

<TS 2724 A

131 96 19 06C 0.79

<TS 2725 A

131 98 12 03C 0.86

<TS 2726 A

131 106 12 03C

-0.83

<TS 2727 A

132 59 13 01C 0.81

<TS 2728 A

132 63 7

07H

-1.03

<TS 2729 A

132 63 9

VS6 0.88

<TS 2730 A

132 67 17 VS2

-0.92

<TS 86 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2731 A

132 67 12 VS2 0.92

<TS 2732 A

132 81 12 DBC 1.74

<TS 2733 A

132 87 9

DBH 1.61

<TS 2734 A

132 91 19 DBC

-1.99

<TS 2735 A

132 93 30 VS2 0.73

<TS 2736 A

132 95 32 VS7 0.79

<TS 2737 A

132 97 19 VS7

-0.75

<TS 2738 A

132 97 8

08C 0

<TS 2739 A

132 99 12 06C 0.83

<TS 2740 A

132 99 14 DBC 1.88

<TS 2741 A

132 107 13 04C 0.15

<TS 2742 A

132 107 11 03C 0.81

<TS 2743 A

132 107 14 03C

-0.99

<TS 2744 A

133 60 13 02H

-0.88

<TS 2745 A

133 60 11 02H 0.94

<TS 2746 A

133 60 11 VS4 0.58

<TS 2747 A

133 60 8

VS7

-0.84

<TS 2748 A

133 60 8

VS2

-0.04

<TS 2749 A

133 64 15 05H

-0.09

<TS 2750 A

133 64 13 VS1 0.92

<TS 2751 A

133 64 8

VS6 0.81

<TS 2752 A

133 66 14 VS4

-0.88

<TS 2753 A

133 70 11 08C 0.88

<TS 2754 A

133 74 19 VS4 0.11

<TS 2755 A

133 74 22 VS4 0.7

<TS 2756 A

133 84 12 08H

-0.18

<TS 2757 A

133 86 15 DBC

-1.85

<TS 2758 A

133 88 17 DBC 1.89

<TS 2759 A

133 92 23 VS6 0.92

<TS 2760 A

133 92 16 VS7 0

<TS 2761 A

133 94 15 VS2 0.79

<TS 2762 A

133 94 14 VS4

-0.75

<TS 2763 A

133 94 22 VS6

-0.99

<TS 2764 A

133 94 13 VS6 0.99

<TS 2765 A

133 94 11 DBC

-1.98

<TS 2766 A

133 94 13 DBC 1.3

<TS 2767 A

133 96 16 VS4

-0.02

<TS 2768 A

133 98 8

DBC 1.86

<TS 2769 A

133 104 14 05C 0.81

<TS 87 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2770 A

133 104 11 05C 0.13

<TS 2771 A

133 104 10 06C

-0.29

<TS 2772 A

133 104 11 07C 0.79

<TS 2773 A

133 104 11 08C 0.79

<TS 2774 A

133 104 10 08C

-0.8

<TS 2775 A

134 65 9

05H

-0.09

<TS 2776 A

134 65 10 06H 0.86

<TS 2777 A

134 65 22 07H

-0.15

<TS 2778 A

134 65 13 08H 0.9

<TS 2779 A

134 65 13 DBH

-1.69

<TS 2780 A

134 65 12 VS1 0.95

<TS 2781 A

134 69 9

VS6 0.97

<TS 2782 A

134 69 18 VS7 0.22

<TS 2783 A

134 69 27 VS7 0.77

<TS 2784 A

134 71 20 VS1 0.77

<TS 2785 A

134 71 8

VS1

-0.9

<TS 2786 A

134 71 16 VS1 0.15

<TS 2787 A

134 73 17 VS6 0.94

<TS 2788 A

134 87 10 VS7 0.86

<TS 2789 A

134 89 9

DBC

-1.99

<TS 2790 A

134 91 33 DBC 1.94

<TS 2791 A

134 91 13 VS6

-0.11

<TS 2792 A

134 91 15 VS1 0.87

<TS 2793 A

134 91 20 VS6

-0.74

<TS 2794 A

134 91 14 VS6 0.89

<TS 2795 A

134 91 30 VS7

-0.87

<TS 2796 A

134 95 28 VS2 0

<TS 2797 A

134 95 29 VS4

-0.95

<TS 2798 A

134 95 13 VS4 0.95

<TS 2799 A

134 95 32 VS6 0.95

<TS 2800 A

134 95 38 VS7 0.84

<TS 2801 A

134 99 14 04C

-0.93

<TS 2802 A

134 103 13 DBC

-2

<TS 2803 A

134 103 14 02C

-0.88

<TS 2804 A

135 68 12 07H 0.86

<TS 2805 A

135 72 27 VS1

-0.95

<TS 2806 A

135 72 14 VS1 0.93

<TS 2807 A

135 72 14 VS7 0.77

<TS 2808 A

135 74 16 VS4

-0.64

<TS 88 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2809 A

135 76 18 DBC 1.91

<TS 2810 A

135 78 15 VS1 0.96

<TS 2811 A

135 78 11 VS4 1.05

<TS 2812 A

135 78 9

VS4 0.07

<TS 2813 A

135 78 37 VS6 0.79

<TS 2814 A

135 78 9

VS7 0.76

<TS 2815 A

135 78 23 08C

-1.09

<TS 2816 A

135 78 7

08C 0.83

<TS 2817 A

135 82 15 08H 0.89

<TS 2818 A

135 82 14 VS4

-0.81

<TS 2819 A

135 82 11 08C

-1.05

<TS 2820 A

135 86 19 VS4 0.92

<TS 2821 A

135 86 16 DBC

-1.87

<TS 2822 A

135 90 22 08C 0.85

<TS 2823 A

135 94 11 VS4 0.93

<TS 2824 A

135 94 14 VS6

-0.79

<TS 2825 A

135 94 22 VS6 0.9

<TS 2826 A

135 94 25 VS7

-0.71

<TS 2827 A

135 94 26 DBC

-1.98

<TS 2828 A

135 98 9

03C

-0.95

<TS 2829 A

135 100 34 VS7

-0.73

<TS 2830 A

135 100 17 DBC 1.7

<TS 2831 A

135 100 17 04C

-0.92

<TS 2832 A

135 100 18 02C 0.86

<TS 2833 A

135 100 19 VS6

-0.84

<TS 2834 A

136 69 16 VS7

-0.86

<TS 2835 A

136 69 11 VS7 0.81

<TS 2836 A

136 69 13 DBC

-1.78

<TS 2837 A

136 69 11 DBC 1.8

<TS 2838 A

136 71 11 04H 0.87

<TS 2839 A

136 79 14 VS7

-0.7

<TS 2840 A

136 79 13 VS7 0.89

<TS 2841 A

136 79 12 08C

-1.07

<TS 2842 A

136 79 30 07C

-0.2

<TS 2843 A

136 79 12 07C

-1.02

<TS 2844 A

136 85 14 08H

-1.18

<TS 2845 A

136 85 8

07H 0.02

<TS 2846 A

136 89 10 DBC 1.57

<TS 2847 A

136 91 11 DBC 1.94

<TS 89 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2848 A

136 91 9

04C

-0.9

<TS 2849 A

136 91 12 05C

-1

<TS 2850 A

136 91 12 05C 0.07

<TS 2851 A

136 91 18 07C

-0.94

<TS 2852 A

136 91 21 08C

-0.96

<TS 2853 A

136 91 28 08C 0.81

<TS 2854 A

136 91 10 VS1 0.85

<TS 2855 A

136 91 25 06C

-0.7

<TS 2856 A

136 93 14 VS6 0.66

<TS 2857 A

137 74 9

VS1

-0.71

<TS 2858 A

137 74 23 VS1 0.07

<TS 2859 A

137 74 18 VS1 0.86

<TS 2860 A

137 74 12 DBH 1.99

<TS 2861 A

137 74 10 03H 0.91

<TS 2862 A

137 76 26 VS4

-0.77

<TS 2863 A

137 76 25 VS4

-0.09

<TS 2864 A

137 76 8

VS2

-0.75

<TS 2865 A

137 76 14 VS2

-0.07

<TS 2866 A

137 76 12 VS6

-0.04

<TS 2867 A

137 78 10 08C 0.79

<TS 2868 A

137 78 19 VS4

-0.77

<TS 2869 A

137 78 21 VS4 0.99

<TS 2870 A

137 78 14 VS7 0.77

<TS 2871 A

137 80 26 VS7 0.86

<TS 2872 A

137 80 16 VS7 0.2

<TS 2873 A

137 80 18 VS6

-0.92

<TS 2874 A

137 82 10 08C

-1.05

<TS 2875 A

137 88 16 VS6

-0.11

<TS 2876 A

137 88 12 VS6

-0.73

<TS 2877 A

137 88 13 VS4

-0.68

<TS 2878 A

137 90 15 DBC 0.88

<TS 2879 A

137 90 14 05H

-0.8

<TS 2880 A

137 92 16 02C 0.83

<TS 2881 A

137 92 8

03C 0.79

<TS 2882 A

137 92 15 04C 0.79

<TS 2883 A

137 92 28 05C 0.02

<TS 2884 A

137 92 11 06C

-0.92

<TS 2885 A

137 92 17 07C

-0.94

<TS 2886 A

137 92 17 08C

-0.94

<TS 90 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4B Steam Generator E-50A Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2887 A

137 92 27 08C 0.81

<TS 2888 A

137 92 16 VS6 0.92

<TS 2889 A

137 92 27 VS6

-0.07

<TS 2890 A

137 92 35 VS6

-0.81

<TS 2891 A

138 75 12 07H 0.88

<TS 2892 A

138 75 28 DBH 1.85

<TS 2893 A

138 75 15 08C 0.04

<TS 2894 A

138 75 10 07C 0.79

<TS 2895 A

138 75 10 08C

-1.03

<TS 2896 A

138 81 9

08H

-0.18

<TS 2897 A

138 81 14 08H 0.79

<TS 2898 A

138 81 29 DBH 2

<TS 2899 A

138 81 11 VS1

-0.99

<TS 2900 A

138 81 9

VS1 0.92

<TS 2901 A

138 81 10 VS2

-0.07

<TS 2902 A

138 81 15 VS4

-1.1

<TS 2903 A

138 81 19 VS4 0.96

<TS 2904 A

138 81 35 VS6

-0.94

<TS 2905 A

138 81 28 VS6 0.99

<TS 2906 A

138 81 17 VS7

-0.02

<TS 2907 A

138 81 16 VS7 0.96

<TS 2908 A

138 81 18 08C

-0.99

<TS 2909 A

138 83 13 08H

-1.08

<TS 2910 A

138 83 5

08H

-0.04

<TS 2911 A

138 83 11 VS1

-0.75

<TS 2912 A

138 83 23 DBH 2

<TS 2913 A

138 85 16 DBC

-1.67

<TS 2914 A

138 85 13 08C

-0.24

<TS 2915 A

138 85 26 VS7 0.81

<TS 2916 A

138 85 13 VS6 0.83

<TS 2917 A

138 85 13 08H

-1.08

<TS 2918 A

138 85 9

08C 0.86

<TS 2919 A

138 87 12 08C 0.77

<TS 2920 A

138 89 16 VS1 0.96

<TS I.

t t

t I*

+

I.

I.

t

+

+

I.

+

I

+

+

+

I-4 I

4

+

+

I.

4 91 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1

B 1

10 14 03C

-0.21

<TS 2

B 1

28 18 02C 0.87

<TS 3

B 1

36 15 03C 0.86

<TS 4

B 1

124 13 02C 0.81

<TS 5

B 1

130 11 03C 0.83

<TS 6

B 1

150 23 01C

-0.7

<TS 7

B 1

158 18 02C 0.86

<TS 8

B 1

160 13 03C

-0.15

<TS 9

B 1

160 15 04H 0.86

<TS 10 B

1 160 11 04H

-0.21

<TS 11 B

1 164 18 02C

-0.87

<TS 12 B

2 11 12 02C 0.83

<TS 13 B

2 141 14 03H

-0.87

<TS 14 B

2 143 12 02C 0.84

<TS 15 B

2 163 11 02H 0.91

<TS 16 B

2 165 18 01C 0.77

<TS 17 B

3 2

11 03H 0.85

<TS 18 B

3 6

19 02C 0.8

<TS 19 B

3 6

14 02C

-0.8

<TS 20 B

3 36 17 03C 0.85

<TS 21 B

3 42 22 03C 0.83

<TS 22 B

3 162 12 02H

-0.28

<TS 23 B

4 125 12 04C

-0.87

<TS 24 B

4 133 12 04C

-0.85

<TS 25 B

4 165 16 02C 0.88

<TS 26 B

4 165 11 02C

-0.91

<TS 27 B

5 138 14 02H

-0.94

<TS 28 B

6 23 13 04C 0.89

<TS 29 B

6 137 12 04C

-0.96

<TS 30 B

6 165 21 02C

-1.12

<TS 31 B

7 2

13 05H 0.96

<TS 32 B

7 26 12 01C

-0.82

<TS 33 B

7 140 14 04C 0.93

<TS 34 B

8 3

14 03C

-0.17

<TS 35 B

8 33 11 03H

-0.91

<TS 36 B

8 129 12 04C

-0.92

<TS 37 B

8 159 11 04C 0.8

<TS 38 B

8 159 8

04C

-0.13

<TS 39 B

8 161 13 03H 0.87

<TS 92 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 40 B

8 161 14 04H 0.88

<TS 41 B

8 165 16 02C

-1.06

<TS 42 B

9 2

10 03C

-0.13

<TS 43 B

9 46 17 DBH 0.57

<TS 44 B

9 140 14 03C 0.87

<TS 45 B

10 133 15 04C

-1.01

<TS 46 B

10 133 13 02C 0.87

<TS 47 B

10 165 16 02H 0.88

<TS 48 B

11 2

15 02H 0.88

<TS 49 B

11 32 11 04C

-0.9

<TS 50 B

11 32 11 DBH

-1.94

<TS 51 B

11 32 10 05H 0.94

<TS 52 B

11 112 9

DBC 1.61

<TS 53 B

11 136 12 02C

-0.19

<TS 54 B

11 164 25 04C 0.77

<TS 55 B

11 164 23 02C

-0.94

<TS 56 B

12 3

15 03C

-0.89

<TS 57 B

12 3

11 02C 0.83

<TS 58 B

13 2

11 04C

-0.13

<TS 59 B

13 4

16 02H

-0.84

<TS 60 B

13 6

14 03C 0.83

<TS 61 B

13 8

12 03C

-0.91

<TS 62 B

13 12 13 02C

-0.89

<TS 63 B

13 56 13 04H 0.9

<TS 64 B

13 62 16 05C

-0.96

<TS 65 B

13 140 16 02H 0.88

<TS 66 B

14 37 9

DBH 1.93

<TS 67 B

14 57 12 03H 0.89

<TS 68 B

14 57 19 DBC

-1.11

<TS 69 B

14 61 10 02H 0.87

<TS 70 B

14 121 10 05C 0.89

<TS 71 B

14 137 11 03H 0.96

<TS 72 B

14 157 14 02C 0.76

<TS 73 B

15 32 11 03H 0.12

<TS 74 B

15 130 24 05C

-0.9

<TS 75 B

15 154 19 04H 0.91

<TS 76 B

15 162 8

DBC

-1.52

<TS 77 B

15 164 16 02H 0.86

<TS 78 B

15 164 13 02C 0.84

<TS 93 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 79 B

16 3

11 02C 0.08

<TS 80 B

16 37 11 05C

-0.22

<TS 81 B

16 55 10 DBH

-1.69

<TS 82 B

16 131 11 03C 0.87

<TS 83 B

16 145 11 04C

-0.91

<TS 84 B

17 2

12 03C 0.83

<TS 85 B

17 2

7 03C

-0.88

<TS 86 B

17 36 13 04H

-0.9

<TS 87 B

17 60 12 02C 0.89

<TS 88 B

17 62 12 01C

-0.96

<TS 89 B

17 62 8

DBH 1.34

<TS 90 B

17 144 13 03H 0.94

<TS 91 B

17 152 12 02H 0.9

<TS 92 B

18 5

11 03C

-0.13

<TS 93 B

18 137 18 VS4 0.89

<TS 94 B

18 141 13 03C

-0.96

<TS 95 B

19 60 11 03H

-0.9

<TS 96 B

19 138 15 03C

-0.9

<TS 97 B

19 156 13 04C 0.77

<TS 98 B

19 164 27 02C 0.86

<TS 99 B

20 161 17 02C 0.82

<TS 100 B

21 4

12 03C 0.85

<TS 101 B

21 8

14 03C

-0.85

<TS 102 B

21 58 16 02C 0.87

<TS 103 B

21 64 16 DBC

-1.7

<TS 104 B

21 164 8

02C

-0.17

<TS 105 B

22 11 13 02C 0.92

<TS 106 B

22 115 9

04C

-0.86

<TS 107 B

22 133 20 VS4 0.84

<TS 108 B

22 133 6

VS4

-0.78

<TS 109 B

22 163 17 02C 0.83

<TS 110 B

23 106 11 VS4

-0.9

<TS 111 B

23 160 13 03C

-0.9

<TS 112 B

23 160 12 02C

-0.18

<TS 113 B

23 160 10 02C

-0.94

<TS 114 B

24 7

15 DBH 1.66

<TS 115 B

24 53 13 02C 0.88

<TS 116 B

25 6

14 04H 0.83

<TS 117 B

25 6

12 02C

-0.81

<TS 94 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 118 B

25 36 8

04H

-0.88

<TS 119 B

25 40 10 04H

-0.85

<TS 120 B

25 52 13 03H

-0.86

<TS 121 B

25 58 13 02C

-0.86

<TS 122 B

25 64 17 DBH

-1.9

<TS 123 B

25 136 13 VS4 0.83

<TS 124 B

25 148 19 02H 1.07

<TS 125 B

27 26 14 05H 0.92

<TS 126 B

27 64 17 DBH

-2

<TS 127 B

27 64 12 05H

-0.06

<TS 128 B

27 64 12 VS4 0.13

<TS 129 B

28 3

13 VS4

-0.9

<TS 130 B

28 39 21 VS4 0.97

<TS 131 B

28 63 8

VS4 0.53

<TS 132 B

29 44 7

VS4

-0.13

<TS 133 B

29 58 10 VS4

-0.11

<TS 134 B

29 120 19 03H 0.94

<TS 135 B

29 156 17 03C

-0.99

<TS 136 B

29 156 11 02H 0.94

<TS 137 B

30 5

11 02H

-0.19

<TS 138 B

30 7

12 03C 0.79

<TS 139 B

30 7

7 03C 0.06

<TS 140 B

30 9

13 02C 0.83

<TS 141 B

30 45 15 VS4 0.88

<TS 142 B

30 47 12 VS4 0.97

<TS 143 B

30 51 12 02H 0.84

<TS 144 B

30 53 14 02C 0.88

<TS 145 B

30 57 11 03C

-0.88

<TS 146 B

30 111 10 03C

-0.91

<TS 147 B

30 115 13 02H 0.84

<TS 148 B

30 127 11 05C 0.92

<TS 149 B

31 4

14 03C

-0.89

<TS 150 B

31 4

16 02C

-0.79

<TS 151 B

31 4

10 03C 0.07

<TS 152 B

31 14 13 05H

-1.06

<TS 153 B

31 46 13 03C 0.86

<TS 154 B

31 50 12 03C 0.84

<TS 155 B

31 160 12 03C 1.02

<TS 156 B

31 160 15 02C 0.88

<TS 95 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 157 B

32 5

13 04H 0.82

<TS 158 B

32 5

15 02C 0.77

<TS 159 B

32 7

11 02H 0.93

<TS 160 B

32 13 16 030 0.87

<TS 161 B

32 45 13 02H 0.85

<TS 162 B

32 45 13 03H 0.89

<TS 163 B

32 109 12 04C 0.85

<TS 164 B

32 151 19 VS4 0.98

<TS 165 B

32 157 17 DBH 1.41

<TS 166 B

33 4

13 010

-0.9

<TS 167 B

33 12 12 VS4 0.86

<TS 168 B

33 32 12 04H 0.96

<TS 169 B

33 52 13 03C 0.84

<TS 170 B

33 54 13 03C

-0.9

<TS 171 B

33 150 15 02H 0.72

<TS 172 B

33 158 17 020 0.81

<TS 173 B

33 160 12 02C

-0.86

<TS 174 B

33 162 16 03C 0.87

<TS 175 B

33 162 16 020

-0.92

<TS 176 B

34 11 14 DBC

-1.19

<TS 177 B

34 11 13 VS4 0.66

<TS 178 B

34 17 15 VS4

-0.4

<TS 179 B

34 31 19 VS4 0.53

<TS 180 B

34 43 11 03H 0.89

<TS 181 B

34 47 11 03H

-0.82

<TS 182 B

34 59 13 03H

-0.97

<TS 183 B

34 103 13 04H

-0.88

<TS 184 B

34 109 7

030 0.89

<TS 185 B

34 113 15 010 0.8

<TS 186 B

34 133 18 030 0.92

<TS 187 B

34 161 14 020 0.85

<TS 188 B

35 4

15 010

-0.88

<TS 189 B

35 4

11 DBC

-0.15

<TS 190 B

35 4

29 DBC 2

<TS 191 B

35 6

11 01H

-0.91

<TS 192 B

35 6

15 050

-0.44

<TS 193 B

35 6

14 030 0.85

<TS 194 B

35 36 12 03H 0.83

<TS 195 B

35 36 20 VS4 0.6

<TS 96 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 196 B

35 42 18 05H 0.98

<TS 197 B

35 46 12 03H

-0.8

<TS 198 B

35 46 14 03H 0.83

<TS 199 B

35 46 13 03C 0.86

<TS 200 B

35 48 10 05H

-0.85

<TS 201 B

35 52 20 DBC 1.22

<TS 202 B

35 52 19 05C 0.84

<TS 203 B

35 56 14 03H

-0.81

<TS 204 B

35 60 11 03H

-0.85

<TS 205 B

35 64 14 05H 1.01

<TS 206 B

36 5

9 03C 0.06

<TS 207 B

36 5

20 03C 0.71

<TS 208 B

36 41 14 03H

-0.85

<TS 209 B

36 45 21 VS4

-0.71

<TS 210 B

36 45 12 VS4 0.75

<TS 211 B

36 49 11 04H 0.89

<TS 212 B

36 49 16 VS4 0.22

<TS 213 B

36 51 10 VS4

-0.69

<TS 214 B

36 51 16 VS4 0.75

<TS 215 B

36 109 8

04C 0.87

<TS 216 B

36 113 9

03C 0.07

<TS 217 B

36 113 16 03C 0.83

<TS 218 B

36 119 13 03C

-0.85

<TS 219 B

36 149 20 VS4

-0.89

<TS 220 B

36 149 11 VS4 0.02

<TS 221 B

36 157 19 02C

-0.85

<TS 222 B

36 161 15 02H 0.97

<TS 223 B

36 161 13 04C

-0.15

<TS 224 B

37 6

16 01H

-0.79

<TS 225 B

37 6

17 03H 0.87

<TS 226 B

37 6

14 02C

-0.13

<TS 227 B

37 6

13 02C

-0.88

<TS 228 B

37 10 8

03C

-0.13

<TS 229 B

37 10 18 03C

-0.97

<TS 230 B

37 32 11 03H 0.94

<TS 231 B

37 36 9

03H

-0.83

<TS 232 B

37 46 10 04H

-0.87

<TS 233 B

37 48 13 02H

-0.8

<TS 234 B

37 50 13 02H

-0.89

<TS 97 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 235 B

37 54 15 02H 0.86

<TS 236 B

37 54 13 04C 0.9

<TS 237 B

37 112 11 02C

-0.94

<TS 238 B

37 122 27 VS4

-0.91

<TS 239 B

37 124 22 VS4 0.76

<TS 240 B

37 124 20 VS4

-0.81

<TS 241 B

37 128 20 VS4 0.92

<TS 242 B

37 128 18 VS4

-0.84

<TS 243 B

37 148 27 VS4

-0.93

<TS 244 B

37 150 14 05H 0.92

<TS 245 B

37 156 18 VS4 0.84

<TS 246 B

37 156 16 VS4

-0.91

<TS 247 B

37 160 13 02H 0.82

<TS 248 B

37 160 23 VS4 0.86

<TS 249 B

37 160 11 VS4

-0.45

<TS 250 B

38 5

13 02C

-0.77

<TS 251 B

38 9

9 03C

-1.05

<TS 252 B

38 9

7 03C

-0.2

<TS 253 B

38 13 18 VS4 0.62

<TS 254 B

38 39 15 02H 0.94

<TS 255 B

38 45 18 02C 0.17

<TS 256 B

38 45 11 01C 0.81

<TS 257 B

38 47 11 04C 0.89

<TS 258 B

38 47 10 01C

-0.22

<TS 259 B

38 49 21 VS4 0.07

<TS 260 B

38 49 25 VS4 0.6

<TS 261 B

38 49 12 02H

-0.86

<TS 262 B

38 51 17 VS4

-0.62

<TS 263 B

38 51 11 02C 0.92

<TS 264 B

38 53 16 03H

-1

<TS 265 B

38 53 22 VS4 0.02

<TS 266 B

38 53 17 VS4 0.82

<TS 267 B

38 107 15 02C 0.82

<TS 268 B

38 109 18 VS4

-0.68

<TS 269 B

38 111 9

04C

-0.82

<TS 270 B

38 115 11 04C 0.81

<TS 271 B

38 125 34 VS4 0.92

<TS 272 B

38 125 9

VS4 0.22

<TS 273 B

38 125 12 VS4

-0.88

<TS 98 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 274 B

38 127 14 02C

-0.92

<TS 275 B

38 127 7

04C 0.13

<TS 276 B

38 127 26 VS4 0.87

<TS 277 B

38 131 20 VS4 0.89

<TS 278 B

38 131 12 VS4

-0.9

<TS 279 B

38 133 14 VS4

-0.83

<TS 280 B

38 135 18 VS4 0.31

<TS 281 B

38 145 19 VS4 0.94

<TS 282 B

38 147 27 VS4

-0.84

<TS 283 B

38 147 17 VS4 0.89

<TS 284 B

38 161 22 02H 0.88

<TS 285 B

38 161 9

DBH 1.55

<TS 286 B

39 6

14 05H 0.88

<TS 287 B

39 6

15 02C

-0.57

<TS 288 B

39 6

12 02C 0.94

<TS 289 B

39 8

12 03C 0.81

<TS 290 B

39 8

15 03C

-0.99

<TS 291 B

39 10 17 03C 0.83

<TS 292 B

39 12 18 VS4

-0.57

<TS 293 B

39 22 14 DBC 1.2

<TS 294 B

39 50 11 VS4

-0.51

<TS 295 B

39 50 8

VS4 0.18

<TS 296 B

39 52 14 03H

-0.91

<TS 297 B

39 102 18 VS4

-0.68

<TS 298 B

39 108 10 DBH

-1.61

<TS 299 B

39 116 18 VS4

-0.84

<TS 300 B

39 116 33 VS4 0.83

<TS 301 B

39 120 19 VS4 0.89

<TS 302 B

39 120 10 VS4

-0.84

<TS 303 B

39 122 15 02C

-0.85

<TS 304 B

39 122 13 VS4 0.73

<TS 305 B

39 134 12 VS4 0.74

<TS 306 B

39 134 17 VS4

-0.88

<TS 307 B

39 146 12 DBC 1.79

<TS 308 B

39 150 20 VS4 0.83

<TS 309 B

39 150 17 VS4 0.07

<TS 310 B

39 160 17 02H 0.9

<TS 311 B

40 5

16 02C

-0.88

<TS 312 B

40 25 8

05H

-0.85

<TS 99 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 313 B

40 31 14 03H 0.85

<TS 314 B

40 31 15 VS4 0.73

<TS 315 B

40 33 12 VS4 0.24

<TS 316 B

40 35 10 04H

-0.13

<TS 317 B

40 39 14 04H

-0.94

<TS 318 B

40 41 11 04H 0.85

<TS 319 B

40 51 14 01H 0.93

<TS 320 B

40 55 10 03H

-0.85

<TS 321 B

40 115 12 03C 0.81

<TS 322 B

40 115 12 04C 0.88

<TS 323 B

40 117 19 03C 0.83

<TS 324 B

40 121 27 VS4 0.83

<TS 325 B

40 121 20 VS4

-0.74

<TS 326 B

40 123 19 VS4 0.81

<TS 327 B

40 123 12 03C

-0.9

<TS 328 B

40 125 19 02C

-0.83

<TS 329 B

40 129 14 04C

-0.91

<TS 330 B

40 143 18 05H 1.01

<TS 331 B

41 6

11 01C 0.86

<TS 332 B

41 6

9 01C

-1.08

<TS 333 B

41 8

19 04C 0.82

<TS 334 B

41 12 9

VS4

-0.87

<TS 335 B

41 12 13 VS4

-0.11

<TS 336 B

41 12 21 VS4 0.75

<TS 337 B

41 12 16 05C 0.02

<TS 338 B

41 14 21 VS4 0.26

<TS 339 B

41 14 16 VS4 0.75

<TS 340 B

41 28 13 05H 0.96

<TS 341 B

41 32 9

VS4 0.75

<TS 342 B

41 32 18 VS4

-0.07

<TS 343 B

41 34 11 04H 0.92

<TS 344 B

41 36 12 03H

-0.49

<TS 345 B

41 40 8

02C

-0.18

<TS 346 B

41 48 11 03H 0.94

<TS 347 B

41 48 12 VS4

-0.88

<TS 348 B

41 54 19 VS4

-0.77

<TS 349 B

41 54 31 VS4 0.86

<TS 350 B

41 56 14 02H 0.94

<TS 351 B

41 60 13 03H

-0.86

<TS 100 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 352 B

41 120 20 05C

-0.92

<TS 353 B

41 120 9

05C 0.55

<TS 354 B

41 122 15 VS4

-0.84

<TS 355 B

41 122 16 VS4 0.77

<TS 356 B

41 128 7

04C

-0.15

<TS 357 B

41 128 14 04C

-1.03

<TS 358 B

41 130 11 05C

-0.88

<TS 359 B

41 132 20 VS4 0.83

<TS 360 B

41 132 12 04C 0.15

<TS 361 B

41 132 10 03C

-0.92

<TS 362 B

41 132 10 02C

-0.15

<TS 363 B

41 134 12 03C 0.92

<TS 364 B

42 27 22 VS4

-0.82

<TS 365 B

42 37 17 VS4 0

<TS 366 B

42 39 17 VS4 0.18

<TS 367 B

42 41 9

04H

-0.86

<TS 368 B

42 41 28 VS4 0.18

<TS 369 B

42 41 36 VS4 0.77

<TS 370 B

42 45 13 VS4 0.73

<TS 371 B

42 47 13 03H

-0.82

<TS 372 B

42 51 38 VS4

-0.75

<TS 373 B

42 51 15 VS4

-0.14

<TS 374 B

42 51 20 VS4 0.8

<TS 375 B

42 57 19 VS4 0.19

<TS 376 B

42 57 36 VS4 0.74

<TS 377 B

42 123 26 VS4 0.94

<TS 378 B

42 133 11 02H

-0.84

<TS 379 B

43 6

11 05H

-0.32

<TS 380 B

43 6

26 02C

-0.15

<TS 381 B

43 6

13 02C

-1.01

<TS 382 B

43 8

13 03C 0.9

<TS 383 B

43 40 11 02C

-0.88

<TS 384 B

43 42 14 05C 0.88

<TS 385 B

43 46 17 03C

-0.86

<TS 386 B

43 48 21 05C 0.93

<TS 387 B

43 126 17 04C

-0.82

<TS 388 B

43 132 14 VS4 0.91

<TS 389 B

43 134 12 03C

-1

<TS 390 B

43 160 15 01H

-0.81

<TS 101 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 391 B

44 19 12 VS4 0.18

<TS 392 B

44 21 24 VS4

-0.89

<TS 393 B

44 21 30 VS4 0.77

<TS 394 B

44 23 15 VS4 0.82

<TS 395 B

44 23 27 DBH

-1.61

<TS 396 B

44 27 25 VS4

-0.8

<TS 397 B

44 27 25 VS4 0.95

<TS 398 B

44 27 12 DBC

-1.32

<TS 399 B

44 29 14 VS4

-0.83

<TS 400 B

44 29 31 VS4

-0.02

<TS 401 B

44 29 12 VS4 0.79

<TS 402 B

44 31 37 VS4

-0.79

<TS 403 B

44 31 21 VS4 0.02

<TS 404 B

44 31 20 DBC 1.19

<TS 405 B

44 31 17 02C 0.86

<TS 406 B

44 33 11 VS4 0.22

<TS 407 B

44 33 11 VS4 0.93

<TS 408 B

44 37 19 VS4 0.77

<TS 409 B

44 37 25 VS4 0.22

<TS 410 B

44 41 16 02C

-0.15

<TS 411 B

44 45 24 VS4 0.79

<TS 412 B

44 45 21 04C 0.44

<TS 413 B

44 45 16 03C 0.88

<TS 414 B

44 47 23 VS4

-0.68

<TS 415 B

44 47 21 VS4 0.02

<TS 416 B

44 53 11 VS4

-0.68

<TS 417 B

44 57 21 VS4

-0.78

<TS 418 B

44 57 15 VS4 0.11

<TS 419 B

44 57 9

VS4 0.82

<TS 420 B

44 59 15 VS4 0.81

<TS 421 B

44 59 25 VS4 0

<TS 422 B

44 61 10 02H

-0.11

<TS 423 B

44 63 12 VS4

-0.93

<TS 424 B

44 63 24 VS4 0.83

<TS 425 B

44 65 23 VS4 0

<TS 426 B

44 65 21 VS4 0.82

<TS 427 B

44 99 14 DBH 1.85

<TS 428 B

44 101 12 04C 0.8

<TS 429 B

44 103 34 VS4 0.89

<TS 102 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 430 B

44 107 16 VS4

-0.91

<TS 431 B

44 107 28 VS4 0.89

<TS 432 B

44 107 8

06C 0.11

<TS 433 B

44 113 11 DBH 1.56

<TS 434 B

44 121 10 03C 0.81

<TS 435 B

44 127 20 02C 0.88

<TS 436 B

44 131 12 VS4 0.84

<TS 437 B

44 131 16 03C 0.9

<TS 438 B

44 137 17 04C

-0.78

<TS 439 B

44 159 15 01H

-0.95

<TS 440 B

45 6

20 02C

-0.15

<TS 441 B

45 6

25 02C

-0.94

<TS 442 B

45 8

10 01C

-0.11

<TS 443 B

45 16 6

DBH

-1.59

<TS 444 B

45 32 23 VS4

-0.84

<TS 445 B

45 32 20 VS4 0.24

<TS 446 B

45 32 15 VS4 1.01

<TS 447 B

45 34 32 VS4 0.07

<TS 448 B

45 34 18 VS4

-0.77

<TS 449 B

45 34 11 VS4 0.8

<TS 450 B

45 34 14 06H 1.19

<TS 451 B

45 36 13 04H

-0.81

<TS 452 B

45 36 27 VS4 0

<TS 453 B

45 36 18 VS4 0.82

<TS 454 B

45 38 10 VS4

-0.71

<TS 455 B

45 38 12 VS4 0.22

<TS 456 B

45 42 24 VS4

-0.84

<TS 457 B

45 42 17 VS4 0.9

<TS 458 B

45 48 13 VS4

-0.81

<TS 459 B

45 48 19 VS4 0.15

<TS 460 B

45 48 19 VS4 0.66

<TS 461 B

45 56 16 03H 0.85

<TS 462 B

45 64 16 DBC

-1.85

<TS 463 B

45 66 15 VS4 0.81

<TS 464 B

45 66 16 VS4 0

<TS 465 B

45 108 7

03H 0.11

<TS 466 B

45 108 12 04C 0

<TS 467 B

45 110 13 02C 0.87

<TS 468 B

45 114 11 03C 0.83

<TS 103 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 469 B

45 118 24 06H

-0.2

<TS 470 B

45 120 18 VS4

-0.83

<TS 471 B

45 120 15 VS4 0.9

<TS 472 B

45 120 12 02C

-0.76

<TS 473 B

45 122 23 VS4

-0.96

<TS 474 B

45 122 29 VS4 0.88

<TS 475 B

45 122 15 06C

-0.66

<TS 476 B

45 126 17 020 0.86

<TS 477 B

45 128 12 03H

-0.98

<TS 478 B

45 130 12 VS4 0.81

<TS 479 B

45 132 17 VS4 0.9

<TS 480 B

45 140 12 VS4

-0.85

<TS 481 B

45 140 26 VS4 0.87

<TS 482 B

45 140 17 DBH

-1.69

<TS 483 B

45 140 13 06C

-0.57

<TS 484 B

45 148 17 VS4 0.75

<TS 485 B

45 148 19 06C

-0.88

<TS 486 B

45 160 9

01H

-0.9

<TS 487 B

45 160 11 01H 0.85

<TS 488 B

46 7

7 010 0.85

<TS 489 B

46 7

21 010

-0.15

<TS 490 B

46 21 11 VS4 0.79

<TS 491 B

46 23 19 VS4

-0.95

<TS 492 B

46 23 23 VS4 0.93

<TS 493 B

46 25 16 VS4

-0.66

<TS 494 B

46 33 27 VS4

-0.81

<TS 495 B

46 33 13 VS4 0.02

<TS 496 B

46 33 12 DBC

-1.63

<TS 497 B

46 35 23 VS4

-0.8

<TS 498 B

46 37 13 02H 0.92

<TS 499 B

46 37 14 VS4

-0.95

<TS 500 B

46 37 20 VS4 0.86

<TS 501 B

46 37 12 DBC

-1.37

<TS 502 B

46 39 25 VS4 0.73

<TS 503 B

46 39 14 VS4 0.11

<TS 504 B

46 41 14 04H 0.91

<TS 505 B

46 47 12 02H

-0.19

<TS 506 B

46 59 13 02H 1.07

<TS 507 B

46 59 13 030 0.89

<TS 104 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear'*

Percent No SG Row Column in Depth Location Elevation TS 508 B

46 69 17 DBH

-1.76

<TS 509 B

46 103 14 04C 0.83

<TS 510 B

46 115 11 02C 0.87

<TS 511 B

46 125 8

02C

-0.94

<TS 512 B

46 129 16 VS4 0.92

<TS 513 B

46 129 12 03C 0.85

<TS 514 B

46 131 14 VS4 0.02

<TS 515 B

46 131 11 VS4

-0.88

<TS 516 B

46 135 12 03H

-0.87

<TS 517 B

46 135 13 VS4

-0.84

<TS 518 B

46 143 15 DBC 1.39

<TS 519 B

46 151 32 VS4 0.87

<TS 520 B

46 159 15 01C 0.13

<TS 521 B

47 8

10 01H 0.9

<TS 522 B

47 12 19 VS4

-0.81

<TS 523 B

47 12 24 VS4 0.9

<TS 524 B

47 14 23 VS4 0.09

<TS 525 B

47 14 26 VS4 0.79

<TS 526 B

47 20 26 VS4

-0.88

<TS 527 B

47 20 28 VS4 0.82

<TS 528 B

47 22 19 VS4

-0.82

<TS 529 B

47 22 18 VS4 1.04

<TS 530 B

47 34 13 VS4 0.96

<TS 531 B

47 40 12 06C

-0.75

<TS 532 B

47 42 14 DBC 1.53

<TS 533 B

47 46 23 VS4

-0.77

<TS 534 B

47 46 20 VS4

-0.02

<TS 535 B

47 46 12 VS4 0.95

<TS 536 B

47 48 14 06C 0.75

<TS 537 B

47 56 17 VS4

-0.77

<TS 538 B

47 56 29 VS4 0.83

<TS 539 B

47 58 17 VS4 0.91

<TS 540 B

47 70 17 VS4

-0.66

<TS 541 B

47 96 23 VS4 0.77

<TS 542 B

47 96 16 VS4

-0.88

<TS 543 B

47 96 11 06C

-0.07

<TS 544 B

47 96 7

DBH 1.79

<TS 545 B

47 98 23 VS4 0.87

<TS 546 B

47 102 12 VS4

-0.89

<TS 105 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 547 B

47 108 27 06H 1.03

<TS 548 B

47 108 16 VS4

-0.38

<TS 549 B

47 108 19 VS4

-0.85

<TS 550 B

47 108 23 VS4 0.76

<TS 551 B

47 114 14 06C 1.03

<TS 552 B

47 116 16 04C

-0.91

<TS 553 B

47 126 28 VS4 0.88

<TS 554 B

47 126 27 VS4

-0.77

<TS 555 B

47 128 24 VS4

-0.78

<TS 556 B

47 132 13 VS4 0.83

<TS 557 B

47 132 10 VS4

-0.78

<TS 558 B

47 132 11 03C

-0.89

<TS 559 B

47 134 9

02C

-0.16

<TS 560 B

47 138 12 DBH

-1.58

<TS 561 B

47 140 16 VS4 0.81

<TS 562 B

47 148 16 04C 0.87

<TS 563 B

47 156 7

01C 0.07

<TS 564 B

48 7

13 01H 0.9

<TS 565 B

48 9

34 VS4

-0.73

<TS 566 B

48 9

34 VS4

-0.04

<TS 567 B

48 9

21 VS4 0.77

<TS 568 B

48 13 22 VS4

-0.77

<TS 569 B

48 13 29 VS4 0.2

<TS 570 B

48 13 21 VS4 0.77

<TS 571 B

48 13 17 VS4

-0.18

<TS 572 B

48 39 13 04H 0.91

<TS 573 B

48 61 13 04H 0.91

<TS 574 B

48 65 26 VS4

-0.82

<TS 575 B

48 67 15 VS4 0.25

<TS 576 B

48 67 14 VS4 0.83

<TS 577 B

48 99 16 03C 0.92

<TS 578 B

48 107 16 04C 0.92

<TS 579 B

48 107 10 02C 0.86

<TS 580 B

48 111 14 04C 0.8

<TS 581 B

48 119 21 04C

-0.87

<TS 582 B

48 123 14 VS4 0.88

<TS 583 B

48 125 15 03C 0.87

<TS 584 B

48 129 13 03C

-0.13

<TS 585 B

48 133 6

04C 0.13

<TS 106 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 586 B

48 139 16 03H 0.96

<TS 587 B

48 141 14 03H

-0.92

<TS 588 B

48 159 11 01H

-0.93

<TS 589 B

48 159 12 01C

-1.01

<TS 590 B

49 8

24 VS4 0.88

<TS 591 B

49 8

5 DBC

-1.67

<TS 592 B

49 10 24 01C 0.93

<TS 593 B

49 12 8

DBC 1.76

<TS 594 B

49 26 16 03H 0.92

<TS 595 B

49 34 12 VS4

-0.81

<TS 596 B

49 34 39 VS4 0.84

<TS 597 B

49 46 21 VS4

-0.82

<TS 598 B

49 56 9

03H

-0.91

<TS 599 B

49 74 27 DBH

-2

<TS 600 B

49 106 14 VS4 0.31

<TS 601 B

49 122 12 04C 0.89

<TS 602 B

49 124 21 VS4

-0.76

<TS 603 B

49 126 12 02C

-0.87

<TS 604 B

49 132 16 03C

-0.86

<TS 605 B

49 144 16 02H 0.93

<TS 606 B

49 158 16 01C 0.09

<TS 607 B

50 7

12 DBH 1.79

<TS 608 B

50 9

12 01C

-0.89

<TS 609 B

50 63 15 DBH

-1.32

<TS 610 B

50 109 9

03C 0.93

<TS 611 B

50 127 13 03C

-0.87

<TS 612 B

50 157 20 01H

-0.9

<TS 613 B

50 159 13 01C 0.88

<TS 614 B

51 36 11 03C 0.86

<TS 615 B

51 36 15 03C

-0.9

<TS 616 B

51 58 12 01H 0.9

<TS 617 B

51 58 14 03H 0.87

<TS 618 B

51 64 17 02C 0.91

<TS 619 B

51 72 13 VS3

-0.7

<TS 620 B

51 116 15 VS3

-0.85

<TS 621 B

51 116 13 02C

-0.89

<TS 622 B

51 134 12 03C

-0.89

<TS 623 B

51 136 13 03C

-0.92

<TS 624 B

51 138 9

02C

-0.13

<TS 107 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 625 B

51 138 8

02C

-0.94

<TS 626 B

51 156 22 VS5

-0.84

<TS 627 B

52 11 10 01C

-0.15

<TS 628 B

52 11 8

01C

-0.95

<TS 629 B

52 25 13 02H 0.82

<TS 630 B

52 65 12 03C 0.87

<TS 631 B

52 107 14 02C 0.87

<TS 632 B

52 123 10 03C

-0.08

<TS 633 B

52 125 10 03C 0.87

<TS 634 B

52 131 27 VS5

-0.55

<TS 635 B

53 8

14 01C 0.79

<TS 636 B

53 32 17 05C 0.68

<TS 637 B

53 50 11 04H 0.91

<TS 638 B

53 56 15 03H 0.87

<TS 639 B

53 60 13 04H 0.99

<TS 640 B

53 80 22 03C 0.77

<TS 641 B

53 106 12 04C 0.83

<TS 642 B

53 108 10 03C 0.86

<TS 643 B

53 118 14 02C

-0.13

<TS 644 B

53 120 11 04C 0.9

<TS 645 B

53 128 17 03C 0.94

<TS 646 B

53 132 14 02C 0.92

<TS 647 B

53 134 12 03C 0.87

<TS 648 B

53 138 12 VS3

-0.93

<TS 649 B

54 17 12 VS3

-0.88

<TS 650 B

54 17 12 VS3 0.9

<TS 651 B

54 61 11 05H 0.96

<TS 652 B

54 69 11 03H 1

<TS 653 B

54 71 13 02H 0.94

<TS 654 B

54 103 11 04C 0.81

<TS 655 B

54 103 12 VS3

-0.85

<TS 656 B

54 117 14 02C 0.89

<TS 657 B

54 121 15 04C

-0.96

<TS 658 B

54 143 13 VS3

-0.87

<TS 659 B

55 14 12 VS5

-0.86

<TS 660 B

55 32 14 VS3

-0.59

<TS 661 B

55 54 14 VS3

-0.75

<TS 662 B

55 56 11 03H 0.91

<TS 663 B

55 60 14 04H 0.91

<TS 108 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 664 B

55 62 13 03C 0.13

<TS 665 B

55 64 17 02C 0.91

<TS 666 B

55 78 13 01C 0.98

<TS 667 B

55 78 11 04H 0.92

<TS 668 B

55 80 9

03H 0.88

<TS 669 B

55 86 11 06C 0.81

<TS 670 B

55 96 10 01C 0.89

<TS 671 B

55 114 17 03C 0.86

<TS 672 B

55 114 11 03C 0.11

<TS 673 B

55 120 14 04H

-0.85

<TS 674 B

55 126 11 03C 0.07

<TS 675 B

55 144 20 VS3

-0.67

<TS 676 B

56 55 12 VS4

-0.71

<TS 677 B

56 59 12 04H 0.87

<TS 678 B

56 77 11 02C 0.81

<TS 679 B

56 77 10 03H

-0.82

<TS 680 B

56 85 21 03C 0.83

<TS 681 B

56 85 14 02C

-0.9

<TS 682 B

56 97 16 04C 0.87

<TS 683 B

56 103 16 DBH 0.24

<TS 684 B

56 129 17 03C 0.82

<TS 685 B

56 129 13 VS3 0.76

<TS 686 B

56 145 17 04C

-0.75

<TS 687 B

56 151 15 06C 0.99

<TS 688 B

56 151 6

06C 0

<TS 689 B

57 16 15 06H

-0.15

<TS 690 B

57 16 8

06H

-1.01

<TS 691 B

57 26 13 06H 0.99

<TS 692 B

57 62 17 04H 0.84

<TS 693 B

57 62 9

02H

-0.88

<TS 694 B

57 62 9

DBC 0.68

<TS 695 B

57 78 9

03H

-0.86

<TS 696 B

57 80 16 03C 0.87

<TS 697 B

57 90 19 03C 0.8

<TS 698 B

57 90 14 03C

-0.89

<TS 699 B

57 118 11 03C

-0.22

<TS 700 B

57 120 8

05C 0.86

<TS 701 B

57 120 9

04C

-0.07

<TS 702 B

57 142 13 VS3 0.76

<TS 109 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 703 B

57 142 16 04C 0.82

<TS 704 B

57 144 15 04C 0.8

<TS 705 B

57 144 14 03C 0.76

<TS 706 B

57 146 9

DBH 1.89

<TS 707 B

57 148 16 04C 0.92

<TS 708 B

58 9

10 05H 0.88

<TS 709 B

58 25 11 06H 0.91

<TS 710 B

58 27 18 05H 0.84

<TS 711 B

58 29 12 VS3

-0.87

<TS 712 B

58 47 12 VS5

-1.1

<TS 713 B

58 47 12 03C

-0.88

<TS 714 B

58 57 11 06C 0.75

<TS 715 B

58 59 11 02H

-0.1

<TS 716 B

58 63 12 04H 0.86

<TS 717 B

58 65 10 04H

-0.13

<TS 718 B

58 71 11 04H

-0.81

<TS 719 B

58 71 11 04H

-0.17

<TS 720 B

58 117 13 06C 0.83

<TS 721 B

58 117 13 03C 0.87

<TS 722 B

58 155 12 01C

-0.93

<TS 723 B

59 26 12 04H 0.88

<TS 724 B

59 26 12 03C 0.81

<TS 725 B

59 48 15 06H 0.97

<TS 726 B

59 48 22 03C 0.9

<TS 727 B

59 56 8

03H 0.13

<TS 728 B

59 66 16 02H

-0.83

<TS 729 B

59 70 11 03H

-0.84

<TS 730 B

59 72 16 03H 0.84

<TS 731 B

59 88 12 03C 0.92

<TS 732 B

59 116 11 03C 0.87

<TS 733 B

59 118 14 03C

-0.91

<TS 734 B

59 120 14 04H

-0.91

<TS 735 B

59 120 14 03C

-0.89

<TS 736 B

59 122 13 03C

-0.18

<TS 737 B

60 39 11 04H 0.87

<TS 738 B

60 41 20 02H

-0.06

<TS 739 B

60 63 13 05H 0.98

<TS 740 B

60 63 11 03H

-0.84

<TS 741 B

60 63 8

02H

-0.13

<TS 110 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 742 B

60 71 6

03H

-0.75

<TS 743 B

60 81 12 02H 0.92

<TS 744 B

60 119 13 03C 0.84

<TS 745 B

60 119 15 VS5

-0.87

<TS 746 B

60 133 15 03C

-0.91

<TS 747 B

61 12 15 06H

-0.24

<TS 748 B

61 28 18 DBC 2

<TS 749 B

61 28 13 04H

-0.86

<TS 750 B

61 42 14 VS3 0.89

<TS 751 B

61 48 12 VS3

-1.02

<TS 752 B

61 48 15 03C 0.86

<TS 753 B

61 62 11 03H

-0.81

<TS 754 B

61 68 16 02H

-0.88

<TS 755 B

61 82 12 02C

-0.92

<TS 756 B

61 102 16 05C

-0.11

<TS 757 B

61 114 17 04C 0.83

<TS 758 B

61 120 16 02C

-0.88

<TS 759 B

61 124 13 02C 0.86

<TS 760 B

61 142 15 03C 0.88

<TS 761 B

61 144 15 06H 0.86

<TS 762 B

61 154 16 VS5 1.01

<TS 763 B

61 156 11 01H 0.8

<TS 764 B

62 11 10 04H 0.87

<TS 765 B

62 17 18 VS5 0.91

<TS 766 B

62 17 17 VS4

-0.73

<TS 767 B

62 23 14 VS5 0.93

<TS 768 B

62 39 11 04H

-0.17

<TS 769 B

62 47 15 03C 0.86

<TS 770 B

62 47 10 DBC

-1.04

<TS 771 B

62 53 10 06H 1

<TS 772 B

62 57 14 02H

-0.93

<TS 773 B

62 57 13 02C 0.82

<TS 774 B

62 59 13 02C 0.91

<TS 775 B

62 75 12 03H 0.9

<TS 776 B

62 85 11 DBC

-1.73

<TS 777 B

62 107 13 02C

-0.86

<TS 778 B

62 111 15 03H 0.13

<TS 779 B

62 123 15 DBC

-1.75

<TS 780 B

62 155 12 01H

-0.81

<TS 111 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 781 B

62 155 13 01H

-0.1

<TS 782 B

62 155 15 01H 0.84

<TS 783 B

63 18 13 DBC

-0.77

<TS 784 B

63 28 12 06H

-0.97

<TS 785 B

63 42 13 VS3 0.95

<TS 786 B

63 56 14 03H

-0.88

<TS 787 B

63 56 9

04H

-0.89

<TS 788 B

63 56 12 03C 0.84

<TS 789 B

63 58 12 04H

-0.92

<TS 790 B

63 60 12 03C

-0.95

<TS 791 B

63 70 19 04H 0.9

<TS 792 B

63 78 12 03H

-0.82

<TS 793 B

63 82 24 VS4 0.94

<TS 794 B

63 82 12 VS5

-0.28

<TS 795 B

63 82 23 VS5 0.98

<TS 796 B

63 86 11 02C

-0.86

<TS 797 B

63 106 14 03H 0.86

<TS 798 B

63 110 14 03H

-0.13

<TS 799 B

63 114 12 03C 0.11

<TS 800 B

63 114 11 03C 0.86

<TS 801 B

63 124 12 04C

-0.92

<TS 802 B

63 126 11 VS3 0.94

<TS 803 B

63 128 14 06C 0.87

<TS 804 B

63 132 24 VS3 1.1

<TS 805 B

63 136 17 VS5 0.97

<TS 806 B

63 136 17 03C 1

<TS 807 B

63 138 16 03C 1

<TS 808 B

63 140 14 06C

-0.22

<TS 809 B

63 140 16 03C 0.9

<TS 810 B

63 140 10 03C 0.11

<TS 811 B

63 146 13 06C 0.86

<TS 812 B

64 35 10 DBC

-1.9

<TS 813 B

64 37 13 06H

-0.15

<TS 814 B

64 51 17 VS5

-0.04

<TS 815 B

64 51 12 VS5 0.71

<TS 816 B

64 81 5

06H

-0.89

<TS 817 B

64 103 10 04C 0.89

<TS 818 B

64 103 6

04C

-0.93

<TS 819 B

64 111 10 03H 0.92

<TS 112 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 820 B

64 113 10 06C 0.91

<TS 821 B

64 121 14 03C 0.88

<TS 822 B

64 135 14 VS3

-0.89

<TS 823 B

64 135 13 VS4

-0.83

<TS 824 B

64 143 13 06H 0.98

<TS 825 B

64 147 11 DBH 1.78

<TS 826 B

64 153 9

01C

-0.88

<TS 827 B

65 16 11 06H

-0.26

<TS 828 B

65 16 13 VS3

-0.82

<TS 829 B

65 32 13 VS3

-0.86

<TS 830 B

65 62 20 04H

-1.18

<TS 831 B

65 110 21 03H 0.81

<TS 832 B

65 118 15 02C 0.85

<TS 833 B

65 122 14 06C 0.81

<TS 834 B

65 122 12 02C 0.88

<TS 835 B

65 130 11 03C 0.99

<TS 836 B

65 144 12 VS4 0.9

<TS 837 B

65 150 11 DBH 1.98

<TS 838 B

66 17 18 06H 0.91

<TS 839 B

66 17 9

06C 0.77

<TS 840 B

66 21 21 06H 0.89

<TS 841 B

66 27 11 06C 0.82

<TS 842 B

66 27 10 06H

-0.86

<TS 843 B

66 29 12 06C

-0.91

<TS 844 B

66 31 11 06C 0.87

<TS 845 B

66 35 17 06C 0.93

<TS 846 B

66 35 17 DBC 1.31

<TS 847 B

66 39 17 VS5

-0.82

<TS 848 B

66 41 16 VS3

-0.78

<TS 849 B

66 41 12 VS3

-0.2

<TS 850 B

66 41 15 VS4

-0.84

<TS 851 B

66 41 11 DBC

-1.55

<TS 852 B

66 45 14 06C 0.84

<TS 853 B

66 47 11 06C

-0.18

<TS 854 B

66 51 11 06C 0.89

<TS 855 B

66 51 13 04C

-0.15

<TS 856 B

66 51 14 06H 0.89

<TS 857 B

66 59 13 04C 0.95

<TS 858 B

66 77 12 VS3

-0.75

<TS 113 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 859 B

66 97 12 01C 0.85

<TS 860 B

66 105 14 VS5 0.85

<TS 861 B

66 107 12 02H

-0.82

<TS 862 B

66 107 10 02C 0.83

<TS 863 B

66 109 23 VS3 0

<TS 864 B

66 125 16 02C 0.94

<TS 865 B

66 137 11 03C 0.9

<TS 866 B

66 137 7

03C 0.11

<TS 867 B

66 143 15 VS5 0.79

<TS 868 B

66 147 17 VS5

-0.62

<TS 869 B

66 147 13 VS3

-0.84

<TS 870 B

66 147 14 VS3 0.84

<TS 871 B

66 149 20 06H 0.83

<TS 872 B

66 153 13 04C

-0.98

<TS 873 B

66 153 18 VS3 0.7

<TS 874 B

67 36 13 06H 0.86

<TS 875 B

67 46 12 DBC 1.63

<TS 876 B

67 52 9

04H 0.88

<TS 877 B

67 56 9

02H 0.9

<TS 878 B

67 56 12 04H

-0.85

<TS 879 B

67 56 13 03C 0.86

<TS 880 B

67 56 12 02C 0.71

<TS 881 B

67 58 18 03C 0.79

<TS 882 B

67 58 9

03C 0.09

<TS 883 B

67 62 18 03C 0.79

<TS 884 B

67 62 14 02C

-0.24

<TS 885 B

67 74 9

04H

-0.86

<TS 886 B

67 76 13 02H

-0.86

<TS 887 B

67 78 11 03H 0.9

<TS 888 B

67 96 13 06C

-0.17

<TS 889 B

67 104 13 03H 0.93

<TS 890 B

67 104 11 04H 0.8

<TS 891 B

67 104 21 06C

-0.15

<TS 892 B

67 108 13 03H 0.93

<TS 893 B

67 112 13 02C

-0.92

<TS 894 B

67 128 21 VS3 0.93

<TS 895 B

67 128 13 06H 0.22

<TS 896 B

67 134 27 06C

-0.97

<TS 897 B

67 134 15 03C 0.88

<TS 114 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 898 B

67 136 19 DBH

-1.64

<TS 899 B

67 138 28 VS3 0.11

<TS 900 B

67 138 29 03C 0.54

<TS 901 B

67 148 19 DBH 1.71

<TS 902 B

67 148 16 VS3 0.77

<TS 903 B

67 150 17 VS3

-0.8

<TS 904 B

67 150 20 VS3 0.91

<TS 905 B

68 17 9

04H 0.92

<TS 906 B

68 21 13 VS5

-0.84

<TS 907 B

68 41 18 04H 0.88

<TS 908 B

68 45 10 DBC

-1.26

<TS 909 B

68 51 10 02H 0.89

<TS 910 B

68 85 13 02C

-0.88

<TS 911 B

68 91 12 03C

-0.88

<TS 912 B

68 93 17 04C

-0.89

<TS 913 B

68 93 12 04C

-0.17

<TS 914 B

68 107 13 02H 0.9

<TS 915 B

68 109 15 02H 0.9

<TS 916 B

68 113 12 03H 0.88

<TS 917 B

68 113 9

04H

-0.92

<TS 918 B

68 113 21 04H 0.9

<TS 919 B

68 117 15 04H 0.97

<TS 920 B

68 139 12 VS3

-0.84

<TS 921 B

68 143 18 06H 0.91

<TS 922 B

68 151 18 VS3

-0.62

<TS 923 B

68 151 16 VS5 0.79

<TS 924 B

69 16 13 VS3

-0.75

<TS 925 B

69 28 14 06H

-0.97

<TS 926 B

69 28 16 06C 0.82

<TS 927 B

69 28 12 06H

-0.15

<TS 928 B

69 32 13 VS4

-0.8

<TS 929 B

69 32 12 VS4 0.86

<TS 930 B

69 34 18 06C

-0.89

<TS 931 B

69 34 16 06C 0.84

<TS 932 B

69 34 20 DBC 1.29

<TS 933 B

69 36 13 04C 0.86

<TS 934 B

69 36 13 DBC 1.5

<TS 935 B

69 48 9

04C 0.13

<TS 936 B

69 52 22 VS3

-0.07

<TS 115 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 937 B

69 52 16 VS5

-0.78

<TS 938 B

69 52 19 VS5 0.8

<TS 939 B

69 52 23 VS4

-0.73

<TS 940 B

69 52 15 VS4

-0.09

<TS 941 B

69 56 15 VS3 0.75

<TS 942 B

69 56 8

VS3 0.13

<TS 943 B

69 56 14 VS5

-0.78

<TS 944 B

69 56 13 VS5 0.73

<TS 945 B

69 66 13 02H 0.92

<TS 946 B

69 72 15 06C

-0.95

<TS 947 B

69 76 16 VS5 0.99

<TS 948 B

69 102 10 03H 0.8

<TS 949 B

69 106 16 06H

-0.87

<TS 950 B

69 110 15 03C 0.94

<TS 951 B

69 114 17 04H 0.88

<TS 952 B

69 120 17 03C 0.88

<TS 953 B

69 120 13 03C 0.09

<TS 954 B

69 122 9

04H 0.95

<TS 955 B

69 124 11 03C

-0.92

<TS 956 B

69 126 17 03H 0.92

<TS 957 B

69 128 21 03C 0.92

<TS 958 B

69 132 16 04H 0.98

<TS 959 B

69 134 16 VS3

-0.83

<TS 960 B

69 134 35 VS4

-0.9

<TS 961 B

69 134 28 VS4 0.97

<TS 962 B

69 134 15 VS5

-0.83

<TS 963 B

69 134 15 VS5 0.7

<TS 964 B

69 136 18 VS5

-0.79

<TS 965 B

69 136 13 VS5 0.82

<TS 966 B

69 140 14 VS3 0.84

<TS 967 B

69 140 15 VS4 0.88

<TS 968 B

69 140 20 VS5

-0.79

<TS 969 B

69 140 16 VS5 0.86

<TS 970 B

69 144 19 VS3

-0.86

<TS 971 B

69 144 26 VS5

-0.81

<TS 972 B

69 150 30 VS3

-0.86

<TS 973 B

69 150 23 VS3 0.83

<TS 974 B

69 150 13 VS4 1.03

<TS 975 B

69 150 23 VS5 0.79

<TS 116 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 976 B

70 31 12 06C 0.89

<TS 977 B

70 45 14 03H 0.92

<TS 978 B

70 47 11 04C 0.02

<TS 979 B

70 51 15 03C 0.88

<TS 980 B

70 75 18 03H

-0.5

<TS 981 B

70 83 11 02C 0.84

<TS 982 B

70 107 12 02H

-0.88

<TS 983 B

70 115 14 04H 0.95

<TS 984 B

70 117 12 03C

-0.93

<TS 985 B

70 129 21 06C

-0.93

<TS 986 B

70 141 21 VS3

-0.86

<TS 987 B

70 143 11 DBC 1.3

<TS 988 B

70 147 15 VS3

-0.89

<TS 989 B

70 153 16 VS4

-0.94

<TS 990 B

70 153 17 VS4 0.97

<TS 991 B

70 153 19 03C 0.15

<TS 992 B

71 14 16 VS4 0.97

<TS 993 B

71 14 12 02H

-0.87

<TS 994 B

71 20 17 DBH

-1.57

<TS 995 B

71 20 17 VS5 0.88

<TS 996 B

71 20 16 DBC 1.46

<TS 997 B

71 36 16 VS3 0.09

<TS 998 B

71 36 17 VS3 0.82

<TS 999 B

71 36 19 VS4 0.8

<TS 1000 B

71 36 14 VS5

-0.69

<TS 1001 B

71 36 26 VS5 0.02

<TS 1002 B

71 36 9

DBC 2

<TS 1003 B

71 36 11 DBC

-2

<TS 1004 B

71 36 9

VS4

-0.83

<TS 1005 B

71 38 16 05H 0.99

<TS 1006 B

71 42 9

04H

-0.79

<TS 1007 B

71 46 13 04H

-0.85

<TS 1008 B

71 52 13 03C 0.88

<TS 1009 B

71 52 8

02C

-0.9

<TS 1010 B

71 58 11 02C

-0.09

<TS 1011 B

71 62 14 03C

-0.22

<TS 1012 B

71 62 10 02C

-0.22

<TS 1013 B

71 80 9

03C 0.13

<TS 1014 B

71 86 15 VS5

-0.84

<TS 117 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1015 B

71 86 10 02C

-0.13

<TS 1016 B

71 86 15 02C

-0.83

<TS 1017 B

71 102 12 05C 0.85

<TS 1018 B

71 104 13 02H 0.82

<TS 1019 B

71 110 12 04H

-0.77

<TS 1020 B

71 112 11 04C 0.84

<TS 1021 B

71 114 10 02C

-0.9

<TS 1022 B

71 116 8

03C

-0.89

<TS 1023 B

71 118 9

020

-0.13

<TS 1024 B

71 132 16 VS5 0.86

<TS 1025 B

71 136 14 060

-0.07

<TS 1026 B

71 136 22 06C

-0.9

<TS 1027 B

71 142 10 06H

-1.06

<TS 1028 B

71 142 11 DBC 0.9

<TS 1029 B

71 144 28 VS3

-0.93

<TS 1030 B

71 144 17 VS3 0.95

<TS 1031 B

71 144 16 DBC 1.63

<TS 1032 B

71 144 14 DBH 1.79

<TS 1033 B

71 146 14 06H 0.22

<TS 1034 B

71 146 10 VS3 0.24

<TS 1035 B

71 146 20 VS4 0.88

<TS 1036 B

71 146 30 VS5

-0.79

<TS 1037 B

71 152 16 VS5 0.86

<TS 1038 B

71 152 10 VS4 0.86

<TS 1039 B

72 17 21 DBH 1.53

<TS 1040 B

72 19 13 VS3 0.15

<TS 1041 B

72 23 13 VS3 0.7

<TS 1042 B

72 25 20 VS3

-0.86

<TS 1043 B

72 25 10 VS3

-0.13

<TS 1044 B

72 41 23 060 0.89

<TS 1045 B

72 47 11 030

-0.93

<TS 1046 B

72 49 27 030 0.95

<TS 1047 B

72 55 15 VS3

-0.99

<TS 1048 B

72 57 10 03C

-0.8

<TS 1049 B

72 59 15 04C 0.82

<TS 1050 B

72 61 16 020 0.81

<TS 1051 B

72 63 12 020 0.85

<TS 1052 B

72 85 14 05C 0.84

<TS 1053 B

72 91 11 02C 0.88

<TS 118 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1054 B

72 109 13 02H 0.86

<TS 1055 B

72 109 14 03H

-0.9

<TS 1056 B

72 113 13 02H

-0.88

<TS 1057 B

72 113 9

02H 0.9

<TS 1058 B

72 113 11 04H 0.82

<TS 1059 B

72 113 12 04C 0.88

<TS 1060 B

72 125 22 06C 0.92

<TS 1061 B

72 129 18 VS5

-0.82

<TS 1062 B

72 139 10 VS3 0.87

<TS 1063 B

72 149 18 VS3 0.93

<TS 1064 B

72 149 26 DBH 1.79

<TS 1065 B

73 14 11 VS4 0.26

<TS 1066 B

73 14 10 VS4

-0.99

<TS 1067 B

73 20 16 VS5 0.8

<TS 1068 B

73 40 9

05H 1.01

<TS 1069 B

73 46 8

04C

-0.91

<TS 1070 B

73 58 12 02C

-0.18

<TS 1071 B

73 58 14 06C

-0.2

<TS 1072 B

73 86 13 02C

-0.9

<TS 1073 B

73 104 18 06C

-0.96

<TS 1074 B

73 106 12 03H 0.92

<TS 1075 B

73 132 13 06H 0.88

<TS 1076 B

73 152 10 VS4

-1.03

<TS 1077 B

73 152 8

VS4 0.33

<TS 1078 B

74 17 30 VS3

-0.89

<TS 1079 B

74 17 16 VS3 0.89

<TS 1080 B

74 17 28 VS4

-0.97

<TS 1081 B

74 19 12 DBC

-1.33

<TS 1082 B

74 19 15 VS4

-0.95

<TS 1083 B

74 21 12 VS3 1.18

<TS 1084 B

74 23 21 VS3

-1.01

<TS 1085 B

74 23 20 VS4

-0.89

<TS 1086 B

74 23 20 DBC 1.2

<TS 1087 B

74 29 13 05H 0.95

<TS 1088 B

74 35 17 DBH 1.38

<TS 1089 B

74 37 14 06H 0.93

<TS 1090 B

74 37 13 04C

-0.89

<TS 1091 B

74 37 11 DBC 1.49

<TS 1092 B

74 43 14 VS3

-0.84

<TS 119 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1093 B

74 43 20 VS4

-0.8

<TS 1094 B

74 45 20 VS5

-0.77

<TS 1095 B

74 47 9

06C 0.09

<TS 1096 B

74 51 11 03C

-0.89

<TS 1097 B

74 53 11 VS3

-0.8

<TS 1098 B

74 55 20 04C 0.84

<TS 1099 B

74 55 14 04C

-0.97

<TS 1100 B

74 71 13 03H 0.92

<TS 1101 B

74 75 15 VS4

-0.64

<TS 1102 B

74 107 14 04H

-0.94

<TS 1103 B

74 111 16 02C

-0.9

<TS 1104 B

74 115 11 04C 0.91

<TS 1105 B

74 117 10 VS4

-0.77

<TS 1106 B

74 117 14 VS3

-1.1

<TS 1107 B

74 119 16 03H 0.81

<TS 1108 B

74 119 19 04H 1

<TS 1109 B

74 127 21 DBH

-1.49

<TS 1110 B

74 141 19 VS5

-0.7

<TS 1111 B

74 151 11 VS3

-0.9

<TS 1112 B

75 16 13 02H 0.88

<TS 1113 B

75 16 13 06H 0.9

<TS 1114 B

75 24 16 VS3 0.8

<TS 1115 B

75 24 15 VS3 0.15

<TS 1116 B

75 24 12 VS4 0.77

<TS 1117 B

75 24 14 DBC

-1.38

<TS 1118 B

75 36 18 VS3 0.8

<TS 1119 B

75 42 17 04C 0.86

<TS 1120 B

75 54 10 04C 0.88

<TS 1121 B

75 60 14 03C 0.82

<TS 1122 B

75 84 15 020

-0.83

<TS 1123 B

75 84 8

02C 0.83

<TS 1124 B

75 102 13 04H 0.89

<TS 1125 B

75 104 18 03H 0.91

<TS 1126 B

75 106 13 02H

-0.92

<TS 1127 B

75 106 10 05H

-0.81

<TS 1128 B

75 106 13 04C

-0.88

<TS 1129 B

75 110 13 04C

-0.92

<TS 1130 B

75 112 9

03H

-0.83

<TS 1131 B

75 132 12 06H

-0.88

<TS 120 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1132 B

75 132 10 DBH

-1.76

<TS 1133 B

75 142 10 DBC 1.01

<TS 1134 B

75 150 15 040 0.91

<TS 1135 B

76 15 22 DBH 1.92

<TS 1136 B

76 21 13 VS3 1.04

<TS 1137 B

76 21 14 VS4

-0.84

<TS 1138 B

76 21 26 VS4 0.9

<TS 1139 B

76 25 12 06H 0.95

<TS 1140 B

76 27 8

06H

-0.88

<TS 1141 B

76 29 10 DBC 1.31

<TS 1142 B

76 29 22 VS4 0.04

<TS 1143 B

76 29 19 VS3 0.64

<TS 1144 B

76 29 20 VS3 0.09

<TS 1145 B

76 29 14 VS3

-0.82

<TS 1146 B

76 33 17 DBH 2.06

<TS 1147 B

76 35 19 DBH 1.7

<TS 1148 B

76 41 11 03C

-0.09

<TS 1149 B

76 41 10 05C

-0.95

<TS 1150 B

76 51 19 VS3 1.04

<TS 1151 B

76 53 8

03C

-0.13

<TS 1152 B

76 55 14 DBH 1.63

<TS 1153 B

76 59 12 05H 1.03

<TS 1154 B

76 59 15 VS3

-0.86

<TS 1155 B

76 65 11 VS4

-0.18

<TS 1156 B

76 73 8

02H

-0.08

<TS 1157 B

76 111 11 04C 0.84

<TS 1158 B

76 113 8

04H 0.17

<TS 1159 B

76 115 7

03H

-0.15

<TS 1160 B

76 117 11 DBC

-1

<TS 1161 B

76 121 16 040 0.86

<TS 1162 B

76 123 9

03H 0.89

<TS 1163 B

76 127 11 DBH

-1.63

<TS 1164 B

76 135 13 VS5 0.83

<TS 1165 B

76 141 27 DBH 1.78

<TS 1166 B

76 151 14 04C 0.88

<TS 1167 B

77 34 12 VS3 0.09

<TS 1168 B

77 34 24 VS3 0.78

<TS 1169 B

77 48 16 VS4 0.95

<TS 1170 B

77 50 13 05H

-0.99

<TS 121 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1171 B

77 56 10 DBH 1.13

<TS 1172 B

77 86 15 02C 0.83

<TS 1173 B

77 86 8

02C

-0.92

<TS 1174 B

77 104 20 05H 0.87

<TS 1175 B

77 104 20 05C 0.85

<TS 1176 B

77 116 17 04H

-0.92

<TS 1177 B

77 122 13 03H 0.87

<TS 1178 B

77 150 18 DBH 1.43

<TS 1179 B

77 150 13 VS3

-0.79

<TS 1180 B

77 150 18 VS4

-0.88

<TS 1181 B

77 150 24 VS4 0.9

<TS 1182 B

78 23 20 DBH

-1.51

<TS 1183 B

78 33 16 03C 0.89

<TS 1184 B

78 35 16 DBH

-1.18

<TS 1185 B

78 47 20 02C 0.89

<TS 1186 B

78 57 21 03C 0.92

<TS 1187 B

78 61 22 VS3

-0.92

<TS 1188 B

78 79 13 VS4 0.91

<TS 1189 B

78 81 11 03H 0.89

<TS 1190 B

78 87 13 03C

-0.83

<TS 1191 B

78 91 17 07H 1.52

<TS 1192 B

78 105 12 02H

-0.89

<TS 1193 B

78 109 11 02H

-0.81

<TS 1194 B

78 109 11 03H 0.15

<TS 1195 B

78 109 15 03H 0.87

<TS 1196 B

78 137 13 04C

-0.9

<TS 1197 B

78 139 12 DBH 1.76

<TS 1198 B

78 141 12 VS3

-0.86

<TS 1199 B

78 141 10 VS4

-0.77

<TS 1200 B

78 145 14 VS5 0.13

<TS 1201 B

79 24 15 VS3

-0.78

<TS 1202 B

79 24 15 VS3 0.92

<TS 1203 B

79 24 28 VS4 0

<TS 1204 B

79 24 30 VS4 0.74

<TS 1205 B

79 30 11 DBC 1.56

<TS 1206 B

79 44 10 04C

-0.86

<TS 1207 B

79 44 12 03C 0.86

<TS 1208 B

79 52 13 02C

-0.26

<TS 1209 B

79 54 12 03C 0.82

<TS 122 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1210 B

79 60 12 03C

-0.95

<TS 1211 B

79 62 12 04C

-0.96

<TS 1212 B

79 62 11 02C

-0.2

<TS 1213 B

79 78 10 VS5 0.86

<TS 1214 B

79 86 14 03H 0.84

<TS 1215 B

79 86 12 03C 0.86

<TS 1216 B

79 108 15 05H 0.74

<TS 1217 B

79 122 20 03H 1.02

<TS 1218 B

79 128 13 03C 0.86

<TS 1219 B

79 150 10 03C

-0.9

<TS 1220 B

80 17 30 DBH 1.59

<TS 1221 B

80 49 15 VS3

-0.82

<TS 1222 B

80 49 13 VS4

-0.77

<TS 1223 B

80 95 12 02H 0.82

<TS 1224 B

80 95 16 03H 0.87

<TS 1225 B

80 95 18 04H 0.88

<TS 1226 B

80 97 14 VS3

-0.2

<TS 1227 B

80 115 14 VS3 0.91

<TS 1228 B

80 115 19 VS4

-0.87

<TS 1229 B

80 129 13 03H 0.9

<TS 1230 B

80 145 29 VS4

-0.73

<TS 1231 B

80 145 16 VS5 0.84

<TS 1232 B

80 145 12 VS5

-0.89

<TS 1233 B

80 149 15 01H

-0.84

<TS 1234 B

81 22 29 VS3 0.89

<TS 1235 B

81 22 28 VS4 0.8

<TS 1236 B

81 24 16 VS3

-0.85

<TS 1237 B

81 24 13 VS3 0.89

<TS 1238 B

81 52 31 VS3 0.84

<TS 1239 B

81 60 15 03C 0.81

<TS 1240 B

81 92 13 02C

-0.88

<TS 1241 B

81 110 12 03H 0.88

<TS 1242 B

81 112 16 02H 0.9

<TS 1243 B

81 114 14 03H 0.81

<TS 1244 B

81 124 12 03C

-0.86

<TS 1245 B

81 126 20 07C 0.77

<TS 1246 B

81 148 15 VS4

-0.86

<TS 1247 B

81 148 17 VS4 0.9

<TS 1248 B

81 148 17 04C 0.88

<TS 123 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1249 B

81 148 10 03C 0.85

<TS 1250 B

82 19 18 03H 0.85

<TS 1251 B

82 19 18 04H 0.84

<TS 1252 B

82 19 13 VS4 0.84

<TS 1253 B

82 21 14 VS5

-0.85

<TS 1254 B

82 41 21 VS3 1.02

<TS 1255 B

82 43 8

VS3

-0.69

<TS 1256 B

82 43 20 VS3 0.18

<TS 1257 B

82 43 22 VS3 0.75

<TS 1258 B

82 43 12 VS4

-0.86

<TS 1259 B

82 43 8

VS4

-0.16

<TS 1260 B

82 43 16 VS4 0.73

<TS 1261 B

82 43 28 VS5

-0.73

<TS 1262 B

82 43 21 VS5

-0.16

<TS 1263 B

82 43 24 VS5 0.16

<TS 1264 B

82 43 16 VS5 0.78

<TS 1265 B

82 53 11 05C 0.95

<TS 1266 B

82 59 15 02C 0.9

<TS 1267 B

82 79 13 04H 0.86

<TS 1268 B

82 91 15 04C

-0.79

<TS 1269 B

82 105 10 02H 0.96

<TS 1270 B

82 111 14 04C

-0.9

<TS 1271 B

82 129 15 DBH 1.78

<TS 1272 B

82 137 16 DBH 1.82

<TS 1273 B

82 143 28 VS3

-0.86

<TS 1274 B

82 143 15 VS4

-0.84

<TS 1275 B

82 145 23 VS3

-0.83

<TS 1276 B

82 145 21 VS3 0.94

<TS 1277 B

82 145 17 VS4

-0.9

<TS 1278 B

82 145 29 VS4 0.88

<TS 1279 B

83 26 8

06H

-1.04

<TS 1280 B

83 28 20 VS6

-1

<TS 1281 B

83 28 16 VS6 0.84

<TS 1282 B

83 52 9

02C

-0.9

<TS 1283 B

83 54 14 04H 0.93

<TS 1284 B

83 64 16 03C 0.94

<TS 1285 B

83 78 13 02C 0.86

<TS 1286 B

83 78 13 01C 0.84

<TS 1287 B

83 106 14 03H 0.9

<TS 124 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1288 B

83 108 12 04C

-0.89

<TS 1289 B

83 114 11 02H 0.88

<TS 1290 B

83 130 10 DBC

-1.21

<TS 1291 B

83 130 10 DBH 1.5

<TS 1292 B

83 140 11 VS3

-0.84

<TS 1293 B

83 148 28 VS4

-1.02

<TS 1294 B

84 19 19 07H

-0.99

<TS 1295 B

84 25 7

VS2

-0.75

<TS 1296 B

84 47 11 VS6 0.71

<TS 1297 B

84 49 8

04C

-0.91

<TS 1298 B

84 55 14 02C 0.82

<TS 1299 B

84 73 13 04H 0.94

<TS 1300 B

84 77 13 05C

-0.9

<TS 1301 B

84 79 8

03H 0.94

<TS 1302 B

84 81 10 02C 0.85

<TS 1303 B

84 87 15 03H 0.89

<TS 1304 B

84 87 13 04C 0.92

<TS 1305 B

84 93 15 02C

-0.9

<TS 1306 B

84 103 7

04C 0.44

<TS 1307 B

84 107 13 02H

-0.83

<TS 1308 B

84 111 12 04H

-0.92

<TS 1309 B

84 111 8

05H 0.96

<TS 1310 B

84 125 12 04H

-0.92

<TS 1311 B

84 125 9

VS2

-0.92

<TS 1312 B

84 145 14 03C

-0.86

<TS 1313 B

84 147 11 07H 0.77

<TS 1314 B

84 147 26 DBH 1.77

<TS 1315 B

85 20 14 VS4

-0.84

<TS 1316 B

85 20 17 VS4 0.91

<TS 1317 B

85 36 15 04H

-0.88

<TS 1318 B

85 36 21 VS6

-0.91

<TS 1319 B

85 78 14 05H 0.93

<TS 1320 B

85 80 10 01H 0.87

<TS 1321 B

85 82 12 VS6

-0.83

<TS 1322 B

85 110 16 04C 0.87

<TS 1323 B

85 112 14 03H 0.49

<TS 1324 B

85 140 14 040 0.86

<TS 1325 B

85 142 20 03C

-0.85

<TS 1326 B

85 144 17 03C

-0.88

<TS 125 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1327 B

85 146 12 04C

-0.92

<TS 1328 B

85 146 16 03C

-0.9

<TS 1329 B

86 21 16 01C

-0.88

<TS 1330 B

86 31 12 06H 0.84

<TS 1331 B

86 33 14 06H 0.89

<TS 1332 B

86 51 19 03C 0.9

<TS 1333 B

86 61 8

02C 0.13

<TS 1334 B

86 67 11 03C

-0.87

<TS 1335 B

86 79 12 04H 0.9

<TS 1336 B

86 89 15 03C 0.81

<TS 1337 B

86 91 7

03C

-0.88

<TS 1338 B

86 111 13 04C

-0.87

<TS 1339 B

86 145 16 03C 0.9

<TS 1340 B

87 20 16 VS4

-0.86

<TS 1341 B

87 30 13 04H 0.94

<TS 1342 B

87 38 15 VS6

-0.69

<TS 1343 B

87 62 12 04C

-0.9

<TS 1344 B

87 74 10 07H 0.94

<TS 1345 B

87 82 15 03H 0.89

<TS 1346 B

87 84 13 02C 0.9

<TS 1347 B

87 88 20 04C

-0.86

<TS 1348 B

87 106 11 03H

-0.79

<TS 1349 B

87 116 15 04C 0.84

<TS 1350 B

87 146 20 VS4

-0.93

<TS 1351 B

87 146 16 VS4 0.95

<TS 1352 B

87 146 32 03C 0.8

<TS 1353 B

88 27 11 04H 0.81

<TS 1354 B

88 27 21 DBH 1.99

<TS 1355 B

88 29 14 06H 0.86

<TS 1356 B

88 67 12 VS2

-0.86

<TS 1357 B

88 67 15 VS2 0.83

<TS 1358 B

88 79 13 07C 0.88

<TS 1359 B

88 87 15 05C 0.86

<TS 1360 B

88 95 21 03C 0.86

<TS 1361 B

88 107 14 04C

-0.92

<TS 1362 B

88 117 12 04C

-0.9

<TS 1363 B

88 133 10 04H

-0.04

<TS 1364 B

89 38 9

05H

-0.86

<TS 1365 B

89 38 12 VS2

-0.97

<TS 126 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1366 B

89 42 13 VS6 0.91

<TS 1367 B

89 44 15 VS2

-0.86

<TS 1368 B

89 44 15 VS6

-0.86

<TS 1369 B

89 54 12 06H

-0.89

<TS 1370 B

89 56 12 02C 0.92

<TS 1371 B

89 56 9

02C

-0.18

<TS 1372 B

89 58 8

DBC 1.75

<TS 1373 B

89 60 16 04C

-0.92

<TS 1374 B

89 78 14 07C 0.85

<TS 1375 B

89 82 14 07C 0.88

<TS 1376 B

89 84 16 03H 0.86

<TS 1377 B

89 92 20 04C 0.46

<TS 1378 B

89 100 12 03H 0.89

<TS 1379 B

89 104 13 05C

-0.9

<TS 1380 B

89 104 15 04C

-0.86

<TS 1381 B

89 104 13 04H 0.89

<TS 1382 B

89 134 16 04H 0.94

<TS 1383 B

89 140 11 DBC 1.46

<TS 1384 B

89 144 13 01H

-0.8

<TS 1385 B

90 23 14 VS4

-0.98

<TS 1386 B

90 31 12 VS2

-0.93

<TS 1387 B

90 55 16 VS2 0.97

<TS 1388 B

90 55 11 02C

-0.88

<TS 1389 B

90 57 14 02C 0.88

<TS 1390 B

90 65 16 03C 0.83

<TS 1391 B

90 69 12 07H

-1.01

<TS 1392 B

90 87 11 02C

-0.88

<TS 1393 B

90 87 12 02C

-0.2

<TS 1394 B

90 89 11 03H 0.91

<TS 1395 B

90 95 18 04C 0.94

<TS 1396 B

90 97 14 04C 0.92

<TS 1397 B

90 115 13 03H

-0.87

<TS 1398 B

90 127 18 04H

-0.87

<TS 1399 B

90 131 12 07H 0.92

<TS 1400 B

91 22 28 VS6 0.97

<TS 1401 B

91 26 13 02C 0.91

<TS 1402 B

91 32 16 02C

-0.91

<TS 1403 B

91 38 14 03H

-0.9

<TS 1404 B

91 54 12 02C 0.91

<TS 127 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1405 B

91 58 16 03C 0.85

<TS 1406 B

91 60 11 03C

-0.92

<TS 1407 B

91 60 9

04C

-0.9

<TS 1408 B

91 64 20 03C

-0.9

<TS 1409 B

91 70 10 04H 0.94

<TS 1410 B

91 70 10 06C

-0.92

<TS 1411 B

91 86 15 VS6 0.92

<TS 1412 B

91 88 16 04H

-0.9

<TS 1413 B

91 88 10 03C 0.86

<TS 1414 B

91 94 13 06C

-0.88

<TS 1415 B

91 98 11 03C 0.86

<TS 1416 B

91 124 17 04C 0.9

<TS 1417 B

91 140 12 04H 0.83

<TS 1418 B

91 144 15 VS4

-0.9

<TS 1419 B

91 144 16 VS4 0.83

<TS 1420 B

92 23 9

VS4

-0.9

<TS 1421 B

92 23 11 VS4 0.73

<TS 1422 B

92 23 12 02C 0.79

<TS 1423 B

92 23 8

02C

-0.61

<TS 1424 B

92 23 9

03H

-0.86

<TS 1425 B

92 31 16 VS2

-1

<TS 1426 B

92 31 12 VS2 0.98

<TS 1427 B

92 35 9

05H 0.85

<TS 1428 B

92 49 13 05H 0.96

<TS 1429 B

92 55 14 03C 0.83

<TS 1430 B

92 57 14 04H 0.79

<TS 1431 B

92 61 11 03C

-0.92

<TS 1432 B

92 69 15 04C 0.92

<TS 1433 B

92 73 8

VS2 0.86

<TS 1434 B

92 75 7

05H 0.93

<TS 1435 B

92 81 7

DBH

-1.8

<TS 1436 B

92 83 19 05H 0.93

<TS 1437 B

92 85 10 03H

-0.89

<TS 1438 B

92 89 12 04H 0.85

<TS 1439 B

92 97 11 04C 0.09

<TS 1440 B

92 97 17 04C 0.88

<TS 1441 B

92 99 11 04C

-0.83

<TS 1442 B

92 105 13 04C

-0.86

<TS 1443 B

92 111 10 07C 0.83

<TS 128 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1444 B

92 125 13 VS2 0.85

<TS 1445 B

93 30 18 VS4

-0.91

<TS 1446 B

93 42 13 VS2 0.75

<TS 1447 B

93 56 12 02C 0.9

<TS 1448 B

93 62 14 03C 0.94

<TS 1449 B

93 62 12 02C 0.9

<TS 1450 B

93 80 12 03C

-0.72

<TS 1451 B

93 98 10 04C

-0.9

<TS 1452 B

93 104 14 04H

-0.82

<TS 1453 B

93 112 11 03H 0.85

<TS 1454 B

93 112 16 VS6 0.68

<TS 1455 B

93 130 10 04H 0.9

<TS 1456 B

93 132 15 04H 0.9

<TS 1457 B

93 136 11 03C 0.86

<TS 1458 B

94 37 16 VS2

-0.86

<TS 1459 B

94 53 13 05H

-0.84

<TS 1460 B

94 57 13 03C 0.79

<TS 1461 B

94 57 16 02C 0.75

<TS 1462 B

94 81 12 02C 0.86

<TS 1463 B

94 93 13 03C

-0.86

<TS 1464 B

94 93 13 04C

-0.11

<TS 1465 B

94 93 10 04C

-0.88

<TS 1466 B

94 101 16 06H

-0.93

<TS 1467 B

94 111 18 VS6

-0.77

<TS 1468 B

94 115 11 04C

-0.94

<TS 1469 B

94 129 17 04H 0.88

<TS 1470 B

94 131 14 03C

-0.86

<TS 1471 B

94 137 13 VS4

-0.84

<TS 1472 B

95 24 19 VS4

-0.78

<TS 1473 B

95 24 12 VS4

-0.13

<TS 1474 B

95 24 14 VS4 0.72

<TS 1475 B

95 36 16 VS4

-0.88

<TS 1476 B

95 36 17 VS4 0.91

<TS 1477 B

95 42 19 DBC

-0.33

<TS 1478 B

95 70 12 04H 0.85

<TS 1479 B

95 70 17 VS6

-0.97

<TS 1480 B

95 84 11 07C 0.07

<TS 1481 B

95 84 17 07C 0.9

<TS 1482 B

95 88 12 02C 0.83

<TS 129 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1483 B

95 102 17 05H 0.82

<TS 1484 B

95 104 15 03H

-0.87

<TS 1485 B

95 104 9

03C 0.13

<TS 1486 B

95 106 19 04C

-0.87

<TS 1487 B

95 116 20 VS2

-1.08

<TS 1488 B

95 126 11 04H 0.91

<TS 1489 B

95 134 18 VS2 0.9

<TS 1490 B

95 134 12 VS2 0.12

<TS 1491 B

95 136 19 03C

-0.37

<TS 1492 B

95 138 39 VS4 0.92

<TS 1493 B

95 138 14 03C 0.79

<TS 1494 B

95 138 19 VS4

-0.79

<TS 1495 B

95 138 16 VS2 0.13

<TS 1496 B

95 140 17 03C

-0.94

<TS 1497 B

95 142 22 VS4 0.75

<TS 1498 B

95 142 14 VS6

-0.79

<TS 1499 B

96 25 11 02H

-1.02

<TS 1500 B

96 29 17 VS4 0.8

<TS 1501 B

96 53 13 05H 0.83

<TS 1502 B

96 57 13 02H 0.84

<TS 1503 B

96 57 16 VS4 1.14

<TS 1504 B

96 61 13 02H 0.87

<TS 1505 B

96 65 13 04C 0.81

<TS 1506 B

96 65 13 02C 0.77

<TS 1507 B

96 71 9

04H

-0.09

<TS 1508 B

96 71 16 04H

-0.94

<TS 1509 B

96 79 9

VS2 0.7

<TS 1510 B

96 95 21 VS2

-0.97

<TS 1511 B

96 95 13 VS2 0.11

<TS 1512 B

96 95 21 VS2 0.75

<TS 1513 B

96 103 15 04C 0.9

<TS 1514 B

96 117 19 VS2 0.85

<TS 1515 B

96 133 9

03H

-0.96

<TS 1516 B

96 133 8

04H

-0.06

<TS 1517 B

96 137 15 VS4

-0.26

<TS 1518 B

96 137 23 VS4 0.9

<TS 1519 B

96 137 18 04C

-0.15

<TS 1520 B

96 137 13 03C 0.89

<TS 1521 B

96 139 19 03C

-0.94

<TS 130 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1522 B

96 141 17 VS2 0.79

<TS 1523 B

96 141 22 VS4 1

<TS 1524 B

97 26 17 VS4

-0.72

<TS 1525 B

97 28 22 03C 0.9

<TS 1526 B

97 34 12 VS6

-0.84

<TS 1527 B

97 38 10 05H 0.87

<TS 1528 B

97 40 15 VS2

-0.77

<TS 1529 B

97 42 13 VS2

-0.93

<TS 1530 B

97 46 11 VS4 0.89

<TS 1531 B

97 54 11 07C 0.86

<TS 1532 B

97 60 17 VS2 0.98

<TS 1533 B

97 60 16 06C 0.9

<TS 1534 B

97 72 11 04H 0.94

<TS 1535 B

97 84 16 07C

-0.88

<TS 1536 B

97 84 10 07C

-0.11

<TS 1537 B

97 86 11 03C 0.83

<TS 1538 B

97 100 13 VS2 0.73

<TS 1539 B

97 130 14 04H 0.85

<TS 1540 B

97 140 13 03H 0.74

<TS 1541 B

97 140 9

DBH 1.54

<TS 1542 B

97 140 14 VS4

-0.86

<TS 1543 B

98 27 15 VS4

-0.91

<TS 1544 B

98 27 21 04C

-0.96

<TS 1545 B

98 39 16 VS4 0.8

<TS 1546 B

98 41 12 VS2

-0.93

<TS 1547 B

98 41 21 VS2 0.82

<TS 1548 B

98 41 25 VS4 0.77

<TS 1549 B

98 49 19 VS2

-0.57

<TS 1550 B

98 51 10 04H 0.89

<TS 1551 B

98 55 29 VS2

-0.9

<TS 1552 B

98 59 16 VS2

-0.94

<TS 1553 B

98 59 14 VS2 0.94

<TS 1554 B

98 71 16 VS2 0.92

<TS 1555 B

98 71 8

VS2

-0.86

<TS 1556 B

98 79 13 03C 0.87

<TS 1557 B

98 79 10 03C 0.09

<TS 1558 B

98 81 15 VS2 0.86

<TS 1559 B

98 93 18 03C 0.88

<TS 1560 B

98 117 15 VS2 0.88

<TS 131 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1561 B

98 133 17 02C 0.79

<TS 1562 B

98 135 22 VS2 0

<TS 1563 B

98 135 24 VS4

-0.72

<TS 1564 B

98 135 28 VS4 0.94

<TS 1565 B

98 139 17 VS4 0.85

<TS 1566 B

98 139 21 VS4 0.22

<TS 1567 B

98 139 14 03C

-0.91

<TS 1568 B

98 139 13 04H

-0.15

<TS 1569 B

99 32 14 02C 0.84

<TS 1570 B

99 40 11 02H 0.81

<TS 1571 B

99 44 9

05H 0.92

<TS 1572 B

99 50 20 05H 0.54

<TS 1573 B

99 52 12 03C 0.86

<TS 1574 B

99 82 13 VS2

-0.83

<TS 1575 B

99 86 11 VS6 0.2

<TS 1576 B

99 132 26 VS2

-0.72

<TS 1577 B

99 132 13 VS2

-0.22

<TS 1578 B

99 132 31 VS2 0.72

<TS 1579 B

99 132 23 VS4 0.9

<TS 1580 B

99 136 18 04C 0.79

<TS 1581 B

99 138 8

DBH 1.98

<TS 1582 B

100 27 22 VS4

-0.97

<TS 1583 B

100 27 12 VS4 0.86

<TS 1584 B

100 29 15 VS6

-0.88

<TS 1585 B

100 29 17 03C 0.82

<TS 1586 B

100 89 12 VS4 0.79

<TS 1587 B

100 103 13 VS2 0.81

<TS 1588 B

100 109 22 VS2

-0.72

<TS 1589 B

100 115 12 03C 0.87

<TS 1590 B

100 121 13 06C 0.92

<TS 1591 B

100 125 31 VS2

-0.7

<TS 1592 B

100 125 35 VS2

-0.07

<TS 1593 B

100 125 17 VS2 0.7

<TS 1594 B

100 125 14 VS4

-0.7

<TS 1595 B

100 125 25 VS4 0.9

<TS 1596 B

100 125 15 VS6

-0.11

<TS 1597 B

100 125 19 VS6 0.97

<TS 1598 B

100 125 13 DBC

-1.8

<TS 1599 B

100 133 16 VS4

-0.72

<TS 132 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1600 B

100 135 13 03H 0.94

<TS 1601 B

101 28 17 VS4

-0.82

<TS 1602 B

101 28 13 VS4

-0.09

<TS 1603 B

101 30 20 04C 0.86

<TS 1604 B

101 30 13 03C 0.87

<TS 1605 B

101 30 20 03C

-0.93

<TS 1606 B

101 30 11 02C 0.84

<TS 1607 B

101 30 12 03H

-0.89

<TS 1608 B

101 32 23 VS2 0.71

<TS 1609 B

101 32 11 VS4 0.93

<TS 1610 B

101 36 12 05H 0.9

<TS 1611 B

101 36 11 03C 0.89

<TS 1612 B

101 38 8

DBC 1.43

<TS 1613 B

101 54 18 02C 0.9

<TS 1614 B

101 66 13 VS4 1.19

<TS 1615 B

101 78 7

05H 0.88

<TS 1616 B

101 98 15 04C

-1.01

<TS 1617 B

101 104 21 DBH 1.36

<TS 1618 B

101 130 12 04C 0.46

<TS 1619 B

101 136 16 03H 0.92

<TS 1620 B

101 138 14 03H 0.86

<TS 1621 B

101 138 11 VS4

-0.88

<TS 1622 B

102 29 13 04C 0.84

<TS 1623 B

102 31 18 02C

-0.89

<TS 1624 B

102 33 22 03C

-0.89

<TS 1625 B

102 35 22 03C 0.89

<TS 1626 B

102 37 11 02C

-0.88

<TS 1627 B

102 41 18 06H 0.86

<TS 1628 B

102 41 9

06H

-0.86

<TS 1629 B

102 49 14 VS2 0.82

<TS 1630 B

102 51 18 07C 0.88

<TS 1631 B

102 85 28 VS6

-0.83

<TS 1632 B

102 93 11 04C

-0.15

<TS 1633 B

102 93 10 04C

-0.92

<TS 1634 B

102 99 17 07C 0.9

<TS 1635 B

102 99 11 07C 0.07

<TS 1636 B

102 113 14 DBH 1.67

<TS 1637 B

102 123 11 04H 0.92

<TS 1638 B

102 127 13 VS4 0.81

<TS 133 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1639 B

102 131 14 DBC 1.32

<TS 1640 B

102 137 13 VS4

-0.86

<TS 1641 B

102 137 19 VS4 0.92

<TS 1642 B

103 30 14 06C

-0.86

<TS 1643 B

103 30 12 01C 0.11

<TS 1644 B

103 36 13 07H 0.97

<TS 1645 B

103 36 14 07C 0.88

<TS 1646 B

103 38 14 02C

-0.86

<TS 1647 B

103 48 17 VS4

-0.86

<TS 1648 B

103 48 9

DBC

-1.3

<TS 1649 B

103 48 12 07C

-0.02

<TS 1650 B

103 58 16 VS2

-0.9

<TS 1651 B

103 62 16 03C 0.86

<TS 1652 B

103 64 28 VS2 0.81

<TS 1653 B

103 82 13 VS2 0.82

<TS 1654 B

103 94 19 VS2

-0.9

<TS 1655 B

103 100 15 07C 0.86

<TS 1656 B

103 108 23 VS6

-0.74

<TS 1657 B

103 120 19 03H 0.92

<TS 1658 B

103 120 8

03H

-0.93

<TS 1659 B

103 122 20 03H 0.9

<TS 1660 B

103 126 18 04H 0.93

<TS 1661 B

103 126 24 VS2 0.15

<TS 1662 B

103 126 19 VS4

-0.7

<TS 1663 B

103 126 35 VS6 0.83

<TS 1664 B

103 128 14 04C 0.9

<TS 1665 B

103 130 20 VS2

-0.13

<TS 1666 B

103 130 11 VS2 0.77

<TS 1667 B

103 132 20 VS2

-0.04

<TS 1668 B

103 132 12 04H 0.96

<TS 1669 B

103 136 19 VS4

-0.88

<TS 1670 B

103 136 23 VS4 0.88

<TS 1671 B

104 31 20 VS4 0.82

<TS 1672 B

104 31 10 DBC

-1.59

<TS 1673 B

104 31 16 02C

-0.2

<TS 1674 B

104 33 12 03H 0.13

<TS 1675 B

104 59 13 VS4 0.94

<TS 1676 B

104 59 12 VS6

-0.9

<TS 1677 B

104 79 12 VS6

-0.83

<TS 134 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1678 B

104 91 13 VS2

-0.79

<TS 1679 B

104 95 20 VS2

-0.73

<TS 1680 B

104 95 14 VS2

-0.09

<TS 1681 B

104 95 18 VS2 0.73

<TS 1682 B

104 117 13 05C 0.9

<TS 1683 B

104 127 10 04H 0.82

<TS 1684 B

104 129 14 06C 0.83

<TS 1685 B

104 131 15 03C 0.85

<TS 1686 B

104 133 8

05C 0.9

<TS 1687 B

104 135 14 VS4 0.95

<TS 1688 B

105 30 14 VS4 0.15

<TS 1689 B

105 30 31 VS4 0.71

<TS 1690 B

105 30 20 02C 0.79

<TS 1691 B

105 32 9

VS4

-1.04

<TS 1692 B

105 32 13 VS4 1.02

<TS 1693 B

105 32 11 01H 0.91

<TS 1694 B

105 34 16 07C

-0.96

<TS 1695 B

105 34 16 03C

-0.91

<TS 1696 B

105 34 23 02C 0.13

<TS 1697 B

105 36 11 04H

-0.19

<TS 1698 B

105 38 18 03C 0.89

<TS 1699 B

105 40 12 03C

-0.91

<TS 1700 B

105 42 12 07C 0.9

<TS 1701 B

105 54 24 VS6

-0.88

<TS 1702 B

105 58 21 VS2

-0.9

<TS 1703 B

105 58 12 VS2 0.96

<TS 1704 B

105 58 17 VS4

-0.7

<TS 1705 B

105 58 16 VS4 0.11

<TS 1706 B

105 58 21 VS6 0.77

<TS 1707 B

105 68 15 VS2 0

<TS 1708 B

105 76 15 VS2 1.05

<TS 1709 B

105 78 9

VS2

-0.26

<TS 1710 B

105 78 11 VS2 1.06

<TS 1711 B

105 78 25 VS6

-0.75

<TS 1712 B

105 78 26 VS6 0.99

<TS 1713 B

105 80 24 VS2

-0.24

<TS 1714 B

105 88 10 VS2

-0.97

<TS 1715 B

105 88 8

07C

-0.13

<TS 1716 B

105 88 12 07C

-0.81

<TS 135 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1717 B

105 90 16 VS2 0.88

<TS 1718 B

105 90 19 VS4 0.92

<TS 1719 B

105 90 17 07C 0.92

<TS 1720 B

105 90 17 03C 0.53

<TS 1721 B

105 96 13 04C

-0.92

<TS 1722 B

105 110 23 DBH 0.99

<TS 1723 B

105 116 17 03H 0.79

<TS 1724 B

105 118 11 03H 0.83

<TS 1725 B

105 118 12 DBH 1.84

<TS 1726 B

105 120 16 03H

-0.91

<TS 1727 B

105 130 21 03C 0.93

<TS 1728 B

105 130 13 VS2 0.29

<TS 1729 B

105 130 15 VS2

-0.73

<TS 1730 B

105 132 11 04H 0.9

<TS 1731 B

105 134 18 VS4 1.03

<TS 1732 B

105 134 22 02C 0.9

<TS 1733 B

105 136 12 01H 0.93

<TS 1734 B

105 136 11 VS4

-0.99

<TS 1735 B

106 31 27 VS4 0.82

<TS 1736 B

106 31 20 03C 0.89

<TS 1737 B

106 31 17 02C 0.84

<TS 1738 B

106 31 17 VS4 0.18

<TS 1739 B

106 33 12 VS4

-0.73

<TS 1740 B

106 33 15 03C 0.11

<TS 1741 B

106 35 15 03H 0.84

<TS 1742 B

106 35 19 04H 0.86

<TS 1743 B

106 35 16 03C 0.8

<TS 1744 B

106 35 16 02C

-0.18

<TS 1745 B

106 37 20 VS2

-0.69

<TS 1746 B

106 39 24 VS2

-1

<TS 1747 B

106 39 25 03C 0.91

<TS 1748 B

106 49 11 04H

-0.09

<TS 1749 B

106 51 17 07C 0.9

<TS 1750 B

106 51 12 VS2 1

<TS 1751 B

106 57 19 VS2 0.94

<TS 1752 B

106 63 13 VS4

-0.92

<TS 1753 B

106 63 24 VS2 0

<TS 1754 B

106 71 13 VS2

-0.44

<TS 1755 B

106 75 15 VS2 1.05

<TS 136 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1756 B

106 77 23 VS2 0.88

<TS 1757 B

106 101 15 VS2

-0.75

<TS 1758 B

106 101 11 VS2

-0.26

<TS 1759 B

106 113 17 VS2 0

<TS 1760 B

106 129 17 04C 0.86

<TS 1761 B

106 131 14 03C

-0.18

<TS 1762 B

107 32 15 VS4

-0.84

<TS 1763 B

107 34 11 VS6

-0.86

<TS 1764 B

107 36 22 VS2 0.86

<TS 1765 B

107 36 15 VS6

-0.73

<TS 1766 B

107 36 11 VS6 0.11

<TS 1767 B

107 40 16 VS2 0.91

<TS 1768 B

107 42 33 VS2

-0.93

<TS 1769 B

107 42 36 VS2 0.93

<TS 1770 B

107 42 23 VS4 0.27

<TS 1771 B

107 42 33 VS4 0.82

<TS 1772 B

107 42 20 VS6

-0.86

<TS 1773 B

107 42 14 VS6 0.93

<TS 1774 B

107 44 18 07C 0.13

<TS 1775 B

107 44 15 06C

-0.15

<TS 1776 B

107 46 20 VS6

-0.88

<TS 1777 B

107 46 9

VS6 0.77

<TS 1778 B

107 52 17 VS6

-0.55

<TS 1779 B

107 52 15 07C 0.88

<TS 1780 B

107 58 15 DBH 1.47

<TS 1781 B

107 74 12 060

-0.88

<TS 1782 B

107 78 13 VS2

-0.88

<TS 1783 B

107 78 17 VS2 0.97

<TS 1784 B

107 82 32 VS2

-0.92

<TS 1785 B

107 82 29 VS2 0.97

<TS 1786 B

107 82 13 VS4 0.13

<TS 1787 B

107 96 24 VS2 0.99

<TS 1788 B

107 96 13 VS4 0.07

<TS 1789 B

107 114 9

VS2 0.26

<TS 1790 B

107 116 29 VS2

-0.83

<TS 1791 B

107 116 28 VS2 0.09

<TS 1792 B

107 116 29 VS2 0.79

<TS 1793 B

107 120 20 DBC 1.61

<TS 1794 B

107 124 13 04C 0.83

<TS 137 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1795 B

107 130 16 02H 0.89

<TS 1796 B

107 130 21 03H 0.86

<TS 1797 B

107 132 16 07C 0.92

<TS 1798 B

107 132 23 04C 0.79

<TS 1799 B

107 132 33 03C 0.81

<TS 1800 B

107 132 19 02C 0.87

<TS 1801 B

108 33 34 VS4 0.91

<TS 1802 B

108 33 15 DBH

-1.33

<TS 1803 B

108 33 25 08H 0.62

<TS 1804 B

108 35 25 04H 0.86

<TS 1805 B

108 35 14 VS2

-0.88

<TS 1806 B

108 35 14 VS2 0.93

<TS 1807 B

108 35 18 VS4

-0.8

<TS 1808 B

108 35 12 VS4 0.73

<TS 1809 B

108 35 16 04C 0.88

<TS 1810 B

108 35 18 04C

-0.91

<TS 1811 B

108 37 11 04C

-0.93

<TS 1812 B

108 37 24 03C

-0.33

<TS 1813 B

108 37 13 02C 0.88

<TS 1814 B

108 43 20 VS4

-0.86

<TS 1815 B

108 45 15 07C 0.84

<TS 1816 B

108 47 25 VS2

-0.71

<TS 1817 B

108 49 12 05H 0.94

<TS 1818 B

108 51 25 VS2

-0.73

<TS 1819 B

108 51 15 VS2 0.92

<TS 1820 B

108 59 18 VS2

-0.81

<TS 1821 B

108 59 18 VS2 0.86

<TS 1822 B

108 63 12 07H 0.13

<TS 1823 B

108 69 14 05H 0.89

<TS 1824 B

108 95 16 04C 0.84

<TS 1825 B

108 103 13 VS2

-0.79

<TS 1826 B

108 103 13 07C 0.9

<TS 1827 B

108 111 14 VS2

-0.15

<TS 1828 B

108 113 21 VS4

-0.92

<TS 1829 B

108 113 22 VS4 0.9

<TS 1830 B

108 115 17 07C 0.9

<TS 1831 B

108 129 11 04H

-0.06

<TS 1832 B

108 131 21 02C 0.9

<TS 1833 B

108 131 15 03C 0.04

<TS 138 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1834 B

108 133 18 02C 0.13

<TS 1835 B

109 34 22 VS4

-0.78

<TS 1836 B

109 34 23 04C 0.11

<TS 1837 B

109 40 19 VS2

-0.84

<TS 1838 B

109 40 19 VS2 1.13

<TS 1839 B

109 40 23 VS4 0.02

<TS 1840 B

109 48 12 VS4

-0.95

<TS 1841 B

109 52 18 VS2

-0.88

<TS 1842 B

109 52 37 VS2 0.95

<TS 1843 B

109 52 14 VS6 0.99

<TS 1844 B

109 54 12 06H 0.81

<TS 1845 B

109 62 18 07C 0.83

<TS 1846 B

109 64 12 08C

-0.89

<TS 1847 B

109 78 18 04C

-0.97

<TS 1848 B

109 84 11 04H

-0.13

<TS 1849 B

109 92 12 07C 0.88

<TS 1850 B

109 96 15 VS2

-0.9

<TS 1851 B

109 104 27 VS2 0.92

<TS 1852 B

109 112 19 07H 0.9

<TS 1853 B

109 112 15 VS2

-1

<TS 1854 B

109 112 16 07C 0.87

<TS 1855 B

109 112 9

06C 0.81

<TS 1856 B

109 114 14 VS2

-0.72

<TS 1857 B

109 114 28 VS2

-0.15

<TS 1858 B

109 114 16 VS2 0.15

<TS 1859 B

109 114 37 VS4

-0.87

<TS 1860 B

109 114 31 VS6

-0.9

<TS 1861 B

109 114 10 VS6 0.68

<TS 1862 B

109 120 15 04C

-0.94

<TS 1863 B

109 126 21 04H 0.85

<TS 1864 B

109 128 15 04H 0.87

<TS 1865 B

109 130 26 02C 0.8

<TS 1866 B

109 130 16 03C 0.95

<TS 1867 B

109 130 13 04C 0.88

<TS 1868 B

109 132 21 04C 0

<TS 1869 B

109 132 18 05C 0.81

<TS 1870 B

109 132 13 08C

-0.48

<TS 1871 B

109 132 10 DBH 1.19

<TS 1872 B

110 37 13 03C

-0.84

<TS 139 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1873 B

110 37 17 04C

-0.82

<TS 1874 B

110 41 13 02C 0.09

<TS 1875 B

110 51 12 05H 0.89

<TS 1876 B

110 55 31 VS2

-0.86

<TS 1877 B

110 55 13 VS2 0.84

<TS 1878 B

110 69 9

06H

-0.82

<TS 1879 B

110 79 20 VS2

-0.02

<TS 1880 B

110 97 17 VS2

-0.81

<TS 1881 B

110 97 16 08H 1.6

<TS 1882 B

110 115 14 03H

-0.87

<TS 1883 B

110 131 18 02C 0.85

<TS 1884 B

110 131 11 02C

-0.91

<TS 1885 B

110 131 26 03C 0.84

<TS 1886 B

110 131 13 03C

-0.94

<TS 1887 B

111 40 10 DBC

-1.64

<TS 1888 B

111 50 20 VS2 0.86

<TS 1889 B

111 56 14 08H 0.07

<TS 1890 B

111 66 9

07H 0.81

<TS 1891 B

111 74 13 05H 0.87

<TS 1892 B

111 84 11 04H

-0.89

<TS 1893 B

111 118 14 04H 0.88

<TS 1894 B

111 120 14 04H 0.9

<TS 1895 B

111 122 12 03C

-0.13

<TS 1896 B

111 122 14 03C

-0.93

<TS 1897 B

111 126 16 03C 0.85

<TS 1898 B

111 128 12 03H

-0.8

<TS 1899 B

111 130 17 02H 0.15

<TS 1900 B

111 130 26 VS4 0.88

<TS 1901 B

112 37 32 04C

-0.95

<TS 1902 B

112 39 12 02H 0.88

<TS 1903 B

112 43 21 VS2

-0.89

<TS 1904 B

112 43 18 VS2 1.02

<TS 1905 B

112 43 16 VS4

-0.84

<TS 1906 B

112 45 13 VS2

-0.86

<TS 1907 B

112 45 10 03H 0.84

<TS 1908 B

112 47 28 VS2

-0.86

<TS 1909 B

112 47 17 VS2 0.93

<TS 1910 B

112 47 24 VS4 0.99

<TS 1911 B

112 49 10 VS4 0.46

<TS 140 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1912 B

112 53 16 VS2

-0.86

<TS 1913 B

112 53 14 VS2 0.92

<TS 1914 B

112 55 13 04H

-0.94

<TS 1915 B

112 57 11 VS2

-0.79

<TS 1916 B

112 59 12 VS2 0.81

<TS 1917 B

112 59 11 VS2 0.13

<TS 1918 B

112 71 14 VS2

-0.9

<TS 1919 B

112 79 19 04H

-0.82

<TS 1920 B

112 79 23 VS2 0.66

<TS 1921 B

112 119 12 03H

-0.88

<TS 1922 B

112 121 19 02C 0.84

<TS 1923 B

112 127 26 03C 0.15

<TS 1924 B

113 36 12 04H

-0.93

<TS 1925 B

113 36 13 08H 0.82

<TS 1926 B

113 36 16 VS2 0.78

<TS 1927 B

113 36 15 VS2

-0.67

<TS 1928 B

113 36 20 VS6

-0.89

<TS 1929 B

113 36 14 VS6 0.69

<TS 1930 B

113 36 18 02C 0.8

<TS 1931 B

113 38 11 VS4

-0.88

<TS 1932 B

113 40 21 03C

-0.61

<TS 1933 B

113 40 13 04H

-0.11

<TS 1934 B

113 40 17 VS4

-0.85

<TS 1935 B

113 42 11 05H 0.02

<TS 1936 B

113 42 15 VS4 0.9

<TS 1937 B

113 42 8

030

-0.15

<TS 1938 B

113 44 18 01H 0.89

<TS 1939 B

113 48 41 VS2

-0.91 PLG 1940 B

113 48 16 VS2 0.93

<TS 1941 B

113 48 36 VS4

-0.74

<TS 1942 B

113 48 8

VS4 0.65

<TS 1943 B

113 66 11 06H 0.83

<TS 1944 B

113 70 17 07C 0.86

<TS 1945 B

113 70 15 07C 0.11

<TS 1946 B

113 84 13 02H

-0.93

<TS 1947 B

113 84 12 04H

-0.86

<TS 1948 B

113 110 14 VS2 0.77

<TS 1949 B

113 110 17 04C 0.9

<TS 1950 B

113 122 12 03C

-1.04

<TS 141 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1951 B

113 130 19 VS4

-0.85

<TS 1952 B

114 37 15 04C 0.88

<TS 1953 B

114 37 30 VS4 0.97

<TS 1954 B

114 37 19 VS4

-0.73

<TS 1955 B

114 37 23 VS2

-0.75

<TS 1956 B

114 37 30 VS2 0.11

<TS 1957 B

114 37 25 DBH 1.26

<TS 1958 B

114 39 23 VS2

-0.88

<TS 1959 B

114 39 35 VS4 0.8

<TS 1960 B

114 39 12 02C 0.8

<TS 1961 B

114 43 10 07H 0.84

<TS 1962 B

114 119 14 VS4 0.96

<TS 1963 B

114 127 17 05C 0.83

<TS 1964 B

114 127 14 04C 0.86

<TS 1965 B

114 127 25 03C 0.83

<TS 1966 B

114 129 11 VS4

-0.78

<TS 1967 B

115 38 38 01C 0.38

<TS 1968 B

115 38 17 02C 0.93

<TS 1969 B

115 38 15 08H 0.88

<TS 1970 B

115 38 19 VS4

-0.8

<TS 1971 B

115 58 12 07H

-0.88

<TS 1972 B

115 68 10 05H 0.93

<TS 1973 B

115 84 13 03H

-0.86

<TS 1974 B

115 86 16 03H 0.93

<TS 1975 B

115 104 11 04H

-0.84

<TS 1976 B

115 114 13 07H 0.83

<TS 1977 B

115 122 15 07H 1

<TS 1978 B

115 124 17 05C

-0.92

<TS 1979 B

115 126 16 04H 0.93

<TS 1980 B

115 126 21 03C 0.83

<TS 1981 B

115 126 17 03C

-0.87

<TS 1982 B

116 43 19 VS4 0.93

<TS 1983 B

116 45 12 06H 0.95

<TS 1984 B

116 45 16 VS2

-0.04

<TS 1985 B

116 45 16 VS4 0.88

<TS 1986 B

116 47 15 VS4 0.9

<TS 1987 B

116 55 13 VS2

-0.88

<TS 1988 B

116 55 18 VS4 0.93

<TS 1989 B

116 55 14 04C 0.86

<TS 142 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 1990 B

116 77 17 VS2 0.77

<TS 1991 B

116 81 18 VS7

-0.88

<TS 1992 B

116 81 10 07C

-0.15

<TS 1993 B

116 81 14 07C

-0.9

<TS 1994 B

116 93 10 04C

-0.96

<TS 1995 B

116 97 9

04C

-0.2

<TS 1996 B

116 103 20 05C 0.88

<TS 1997 B

116 111 15 05H

-0.96

<TS 1998 B

116 111 9

05H 0.96

<TS 1999 B

116 111 11 08C 0.87

<TS 2000 B

116 111 20 04C

-0.96

<TS 2001 B

116 115 22 VS4 0.85

<TS 2002 B

116 117 19 030

-0.15

<TS 2003 B

116 117 13 03C

-0.9

<TS 2004 B

116 125 14 05C 0.86

<TS 2005 B

116 125 15 04C 0.86

<TS 2006 B

116 125 11 040 0.02

<TS 2007 B

116 125 33 03C 1.05

<TS 2008 B

117 40 12 050 0.78

<TS 2009 B

117 40 21 03C

-0.89

<TS 2010 B

117 40 22 020

-0.84

<TS 2011 B

117 40 14 02C

-0.11

<TS 2012 B

117 40 11 01C

-0.86

<TS 2013 B

117 40 19 040

-0.2

<TS 2014 B

117 40 16 020 0.8

<TS 2015 B

117 44 15 02C 0.82

<TS 2016 B

117 48 15 030

-0.88

<TS 2017 B

117 66 10 06H 0.94

<TS 2018 B

117 66 13 070 0.9

<TS 2019 B

117 68 11 05H 0.98

<TS 2020 B

117 82 9

06H

-0.91

<TS 2021 B

117 90 14 VS4 0.29

<TS 2022 B

117 90 18 08C 0.92

<TS 2023 B

117 108 14 03H

-0.87

<TS 2024 B

117 108 13 04H 0.98

<TS 2025 B

117 112 19 04H 1

<TS 2026 B

118 41 14 02H 0.88

<TS 2027 B

118 41 14 03C

-0.22

<TS 2028 B

118 43 16 VS4 0.9

<TS 143 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2029 B

118 43 17 VS6

-0.02

<TS 2030 B

118 73 12 VS6

-0.92

<TS 2031 B

118 73 12 VS7

-0.83

<TS 2032 B

118 87 14 VS2 0.94

<TS 2033 B

118 89 26 VS2 0.99

<TS 2034 B

118 89 16 VS4 0.68

<TS 2035 B

118 97 12 VS2

-0.9

<TS 2036 B

118 101 11 08C 0.86

<TS 2037 B

118 105 15 VS4

-0.55

<TS 2038 B

118 117 17 04C

-0.15

<TS 2039 B

118 121 11 03H

-0.88

<TS 2040 B

118 123 23 04C

-0.92

<TS 2041 B

118 123 14 03C 0.83

<TS 2042 B

118 123 13 02C 0.82

<TS 2043 B

119 42 14 02H 0.88

<TS 2044 B

119 42 19 VS7

-0.84

<TS 2045 B

119 42 14 05C 0.84

<TS 2046 B

119 42 22 04C

-0.48

<TS 2047 B

119 42 19 03C 0.46

<TS 2048 B

119 44 17 02H 0.81

<TS 2049 B

119 44 13 01C 0.78

<TS 2050 B

119 46 20 02C 0.79

<TS 2051 B

119 88 23 08C 0.9

<TS 2052 B

119 88 9

08C

-0.15

<TS 2053 B

119 104 14 VS1

-0.74

<TS 2054 B

119 110 16 04C 0.87

<TS 2055 B

119 112 19 04C 0.89

<TS 2056 B

119 112 16 03C 0.85

<TS 2057 B

119 112 12 03C

-0.86

<TS 2058 B

119 122 15 04H

-0.92

<TS 2059 B

120 43 11 02H 0.86

<TS 2060 B

120 43 19 01C

-0.91

<TS 2061 B

120 43 9

01C 0.86

<TS 2062 B

120 45 11 02C 0.77

<TS 2063 B

120 47 26 03C 0.86

<TS 2064 B

120 47 8

03C

-0.95

<TS 2065 B

120 49 11 03C

-0.9

<TS 2066 B

120 55 12 07C

-0.9

<TS 2067 B

120 61 14 08C 0.9

<TS 144 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2068 B

120 103 16 07H 0.97

<TS 2069 B

120 105 23 VS2

-0.83

<TS 2070 B

120 113 22 VS2

-0.94

<TS 2071 B

120 113 16 VS2 0.86

<TS 2072 B

120 115 26 03C 0.89

<TS 2073 B

120 121 12 03H 0.82

<TS 2074 B

121 44 18 01H 0.89

<TS 2075 B

121 44 13 03C 0.84

<TS 2076 B

121 104 14 03H 0.88

<TS 2077 B

121 104 18 05H 0.8

<TS 2078 B

121 104 12 04H 0.86

<TS 2079 B

121 114 13 03C 0.94

<TS 2080 B

121 114 18 VS4

-0.96

<TS 2081 B

121 114 13 04C

-0.92

<TS 2082 B

121 118 19 02C 0.82

<TS 2083 B

121 120 15 02C

-0.13

<TS 2084 B

121 122 11 02H 0.88

<TS 2085 B

122 71 11 05H 0.89

<TS 2086 B

122 71 11 VS2

-0.75

<TS 2087 B

122 111 10 06C 0.88

<TS 2088 B

123 52 16 02C 0.86

<TS 2089 B

123 72 13 VS4

-0.88

<TS 2090 B

123 72 13 VS7 0.88

<TS 2091 B

123 78 20 05H

-1.1

<TS 2092 B

123 84 11 04H

-0.13

<TS 2093 B

123 98 12 07C 0.9

<TS 2094 B

123 98 10 06C 0.81

<TS 2095 B

123 116 37 VS6

-0.76

<TS 2096 B

123 116 18 05C

-0.95

<TS 2097 B

123 116 12 04C 0.89

<TS 2098 B

123 116 11 03C 0.91

<TS 2099 B

123 118 35 VS6

-0.93

<TS 2100 B

123 118 22 VS7

-0.95

<TS 2101 B

123 118 14 08C 0.85

<TS 2102 B

124 47 13 03C 0.88

<TS 2103 B

124 47 9

01C

-0.13

<TS 2104 B

124 49 17 02C

-0.95

<TS 2105 B

124 51 13 VS4 0.64

<TS 2106 B

124 55 11 05H

-0.17

<TS 145 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2107 B

124 57 12 VS7

-1.08

<TS 2108 B

124 73 12 VS2 0.83

<TS 2109 B

124 85 13 VS2 0.22

<TS 2110 B

124 85 12 VS2 0.7

<TS 2111 B

124 85 16 VS4

-0.66

<TS 2112 B

124 87 16 VS4 0.88

<TS 2113 B

124 93 17 VS1 0.61

<TS 2114 B

124 93 31 VS2 0

<TS 2115 B

124 93 11 VS2 0.72

<TS 2116 B

124 93 18 VS2

-0.72

<TS 2117 B

124 93 12 VS4 0.92

<TS 2118 B

124 95 20 VS2

-0.02

<TS 2119 B

124 95 15 VS4

-0.9

<TS 2120 B

124 95 20 VS4 0.92

<TS 2121 B

124 97 14 06C 0.86

<TS 2122 B

124 101 12 04C

-0.85

<TS 2123 B

124 105 13 06C 0.86

<TS 2124 B

124 111 10 02C

-0.13

<TS 2125 B

124 113 12 03C 0.87

<TS 2126 B

124 113 9

03C

-0.2

<TS 2127 B

124 117 13 VS4 0.78

<TS 2128 B

124 117 20 VS7

-0.2

<TS 2129 B

124 117 11 06C 0.83

<TS 2130 B

124 117 10 06C

-0.89

<TS 2131 B

124 117 21 04C 0.83

<TS 2132 B

124 119 12 08C

-0.15

<TS 2133 B

124 119 12 08C 0.91

<TS 2134 B

125 48 7

VS4

-1.01

<TS 2135 B

125 48 16 VS4 0.9

<TS 2136 B

125 48 16 VS6 0.9

<TS 2137 B

125 78 12 03H

-0.89

<TS 2138 B

125 82 11 05H

-0.87

<TS 2139 B

125 82 13 VS1

-0.79

<TS 2140 B

125 94 23 VS2

-0.7

<TS 2141 B

125 94 18 VS2

-0.15

<TS 2142 B

125 100 16 08C 0.88

<TS 2143 B

125 104 20 07H 0.86

<TS 2144 B

125 104 23 070

-0.2

<TS 2145 B

125 112 21 02C 0.85

<TS 146 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2146 B

125 114 17 03C 0.85

<TS 2147 B

125 116 17 02H 0.89

<TS 2148 B

125 116 12 03H 0.83

<TS 2149 B

125 116 18 VS4

-0.87

<TS 2150 B

125 116 7

VS4 0.89

<TS 2151 B

125 118 13 05H

-1.04

<TS 2152 B

126 51 12 01C 0.83

<TS 2153 B

126 55 17 02C 0.88

<TS 2154 B

126 55 13 06H 0.92

<TS 2155 B

126 61 15 VS1 0.88

<TS 2156 B

126 81 11 VS4

-0.86

<TS 2157 B

126 83 17 VS1

-0.18

<TS 2158 B

126 91 8

VS4

-0.86

<TS 2159 B

126 91 21 VS2 0.04

<TS 2160 B

126 95 19 VS6 1.05

<TS 2161 B

126 95 25 VS4

-0.9

<TS 2162 B

126 95 16 VS2

-0.02

<TS 2163 B

126 99 19 08C 0.85

<TS 2164 B

126 99 14 07C 0.83

<TS 2165 B

126 103 17 VS4 0.85

<TS 2166 B

126 109 14 04H 0.87

<TS 2167 B

126 115 9

02C 0.11

<TS 2168 B

126 115 20 02C 0.83

<TS 2169 B

127 52 12 01H

-0.06

<TS 2170 B

127 54 19 01H

-0.83

<TS 2171 B

127 72 10 05H 0.89

<TS 2172 B

127 92 22 08C

-0.15

<TS 2173 B

127 92 11 VS6

-1.01

<TS 2174 B

127 102 13 07C

-0.15

<TS 2175 B

127 104 14 06C 0.85

<TS 2176 B

127 106 21 07C

-0.19

<TS 2177 B

127 108 13 06C 0.92

<TS 2178 B

127 110 16 02C 0.81

<TS 2179 B

127 112 20 02C 0.87

<TS 2180 B

127 112 13 04C

-1.02

<TS 2181 B

127 114 18 01H

-0.88

<TS 2182 B

127 114 13 02H 0.83

<TS 2183 B

127 114 12 02C 0.85

<TS 2184 B

127 114 8

03C 0.85

<TS 147 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2185 B

128 53 16 01H

-0.11

<TS 2186 B

128 55 20 01C

-0.53

<TS 2187 B

128 57 12 01H

-0.86

<TS 2188 B

128 73 24 VS1 0.18

<TS 2189 B

128 73 14 VS4 0.88

<TS 2190 B

128 73 11 06H 0.02

<TS 2191 B

128 73 14 06H 0.94

<TS 2192 B

128 99 12 07C 0.85

.<TS 2193 B

128 101 23 05C 0.87

<TS 2194 B

128 109 14 02C

-0.11

<TS 2195 B

128 113 25 02C

-0.87

<TS 2196 B

129 56 21 01H 0.89

<TS 2197 B

129 56 19 01C 0.85

<TS 2198 B

129 58 11 01H

-0.84

<TS 2199 B

129 64 9

VS7

-0.83

<TS 2200 B

129 68 10 02H

-0.84

<TS 2201 B

129 84 18 06H 0.86

<TS 2202 B

129 102 22 08C

-0.97

<TS 2203 B

129 102 9

06C

-0.24

<TS 2204 B

129 102 13 08C 0.11

<TS 2205 B

129 104 15 07C

-0.2

<TS 2206 B

129 106 12 06C 0.82

<TS 2207 B

129 106 8

08C

-0.2

<TS 2208 B

129 106 20 08C 0.85

<TS 2209 B

129 108 6

06C 0.85

<TS 2210 B

129 108 11 02C 0.88

<TS 2211 B

129 110 17 02C 0.79

<TS 2212 B

130 55 19 01H 0.98

<TS 2213 B

130 55 19 02C 0.85

<TS 2214 B

130 65 15 VS4 0.61

<TS 2215 B

130 65 26 VS7 0.9

<TS 2216 B

130 65 10 VS2

-0.24

<TS 2217 B

130 69 12 05H 0.84

<TS 2218 B

130 79 10 VS2

-0.94

<TS 2219 B

130 91 22 DBC 1.31

<TS 2220 B

130 107 18 DBC

-1.75

<TS 2221 B

130 109 11 04H 0.85

<TS 2222 B

131 58 33 01C 0.83

<TS 2223 B

131 60 12 VS6 0.83

<TS 148 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2224 B

131 64 23 VS7 0.99

<TS 2225 B

131 70 14 03C 0.85

<TS 2226 B

131 78 16 VS6

-0.88

<TS 2227 B

131 82 17 08H

-0.84

<TS 2228 B

131 88 13 07C 0.88

<TS 2229 B

131 96 12 08H

-0.11

<TS 2230 B

131 96 22 04C 0.86

<TS 2231 B

131 98 33 VS6 0.88

<TS 2232 B

131 98 31 VS7 0.72

<TS 2233 B

131 98 16 DBC 1.79

<TS 2234 B

131 100 9

06C 0.85

<TS 2235 B

131 102 21 06C

-0.96

<TS 2236 B

131 102 17 05C 0.83

<TS 2237 B

131 102 13 04C 0.89

<TS 2238 B

131 104 29 VS7 0.88

<TS 2239 B

131 104 15 DBC 1.68

<TS 2240 B

131 108 13 07H

-1.09

<TS 2241 B

132 61 12 01H 1.01

<TS 2242 B

132 75 11 02H 0.86

<TS 2243 B

132 81 12 05H 0.89

<TS 2244 B

132 91 14 DBC 1.32

<TS 2245 B

132 97 14 VS1 0.81

<TS 2246 B

132 97 22 VS2

-0.75

<TS 2247 B

132 97 8

VS2

-0.11

<TS 2248 B

132 97 15 VS4

-0.94

<TS 2249 B

132 97 6

VS4 0.53

<TS 2250 B

132 97 11 VS7 0.94

<TS 2251 B

132 101 15 VS7 0.79

<TS 2252 B

132 101 20 06C 0.85

<TS 2253 B

132 101 14 06C

-0.2

<TS 2254 B

132 103 16 VS7

-0.88

<TS 2255 B

132 103 12 DBC

-1.93

<TS 2256 B

132 107 26 02C

-0.9

<TS 2257 B

133 68 13 02H 0.88

<TS 2258 B

133 74 15 03H 0.86

<TS 2259 B

133 76 14 07C 0.85

<TS 2260 B

133 90 14 DBC

-1.93

<TS 2261 B

133 100 19 VS7

-0.15

<TS 2262 B

133 102 17 VS7

-0.83

<TS 149 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2263 B

133 102 20 07C

-1.01

<TS 2264 B

133 104 23 VS7 0.9

<TS 2265 B

133 104 12 VS7

-0.81

<TS 2266 B

133 104 15 DBC 1.89

<TS 2267 B

134 63 15 07C 0.83

<TS 2268 B

134 63 18 DBH

-1.68

<TS 2269 B

134 65 19 02H 0.86

<TS 2270 B

134 65 12 VS2

-0.72

<TS 2271 B

134 69 27 VS7 0.92

<TS 2272 B

134 69 17 04H 0.86

<TS 2273 B

134 95 21 DBC 1.72

<TS 2274 B

134 95 12 06C 0.83

<TS 2275 B

134 97 13 VS6

-0.87

<TS 2276 B

134 97 15 VS6 0.83

<TS 2277 B

134 99 12 VS4

-0.89

<TS 2278 B

134 99 15 VS6

-0.76

<TS 2279 B

134 99 26 VS6 0.98

<TS 2280 B

134 101 24 VS7 0.92

<TS 2281 B

135 68 13 02H

-0.96

<TS 2282 B

135 68 24 VS7 0.92

<TS 2283 B

135 72 21 VS7

-0.9

<TS 2284 B

135 76 22 VS7

-0.92

<TS 2285 B

135 76 16 08C 0.83

<TS 2286 B

135 76 19 08C

-0.96

<TS 2287 B

135 80 18 07H

-0.77

<TS 2288 B

135 82 22 VS7

-0.9

<TS 2289 B

135 82 23 VS7 0.95

<TS 2290 B

135 90 31 VS7 0.7

<TS 2291 B

135 92 37 VS7

-0.61

<TS 2292 B

135 92 33 08C 0.87

<TS 2293 B

135 92 25 07C 0.78

<TS 2294 B

135 94 26 DBC 1.75

<TS 2295 B

135 96 14 04C 0.83

<TS 2296 B

135 98 16 VS6

-0.8

<TS 2297 B

136 69 20 DBC 1.9

<TS 2298 B

136 77 18 03H 0.91

<TS 2299 B

136 87 15 08C

-1.01

<TS 2300 B

136 91 13 08C

-0.18

<TS 2301 B

136 91 23 DBC 1.88

<TS 150 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2302 B

136 95 21 03C 0.88

<TS 2303 B

136 97 30 VS7

-0.79

<TS 2304 B

136 97 12 08C 0.11

<TS 2305 B

136 97 16 08C

-0.92

<TS 2306 B

136 97 13 07C 0.87

<TS 2307 B

136 97 19 03C 0.88

<TS 2308 B

136 97 15 VS7 0.9

<TS 2309 B

137 74 15 06H 0.81

<TS 2310 B

137 76 12 05H 0.84

<TS 2311 B

137 78 13 03H

-0.84

<TS 2312 B

137 80 19 08H 0.88

<TS 2313 B

137 90 23 DBH 1.75

<TS 2314 B

137 90 11 VS1

-0.81

<TS 2315 B

137 90 15 VS4 0.18

<TS 2316 B

137 90 11 VS4 0.7

<TS 2317 B

137 90 16 VS6

-0.66

<TS 2318 B

137 90 17 VS7

-0.88

<TS 2319 B

137 90 17 VS7 0.88

<TS 2320 B

137 90 18 DBC 1.97

<TS 2321 B

137 92 18 VS6

-0.85

<TS 2322 B

137 92 21 VS6 0.94

<TS 2323 B

137 92 23 VS7

-0.68

<TS 2324 B

137 92 15 08C

-1.03

<TS 2325 B

137 92 17 07C 0.07

<TS 2326 B

137 92 10 04C 0.83

<TS 2327 B

138 75 9

08H

-0.13

<TS 2328 B

138 77 20 02H 0.92

<TS 2329 B

138 77 13 03H

-0.92

<TS 2330 B

138 77 21 VS4 0.94

<TS 2331 B

138 79 15 03H 0.88

<TS 2332 B

138 79 23 VS1

-0.66

<TS 2333 B

138 79 23 VS2 0.79

<TS 2334 B

138 79 20 VS4 0.94

<TS 2335 B

138 79 19 VS6

-0.9

<TS 2336 B

138 79 20 VS6 0.96

<TS 2337 B

138 81 22 VS4

-0.88

<TS 2338 B

138 81 14 08C

-1.07

<TS 2339 B

138 85 14 08H 0.85

<TS 2340 B

138 85 27 DBH 1.79

<TS 151 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 4C Steam Generator E-50B Indications (all indications due to tube wear)

Percent No SG Row Column in Depth Location Elevation TS 2341 B

138 87 20 VS1

-0.81

<TS 2342 B

138 87 18 VS4

-0.79

<TS 2343 B

138 87 13 VS1 0.92

<TS 2344 B

138 89 19 VS4

-0.63

<TS 2345 B

138 89 12 VS6 0.85

<TS 2346 B

138 89 16 VS7

-0.79

<TS 2347 B

138 89 33 VS7 0.92

<TS 2348 B

138 89 14 07C 0.77

<TS 2349 B

138 89 12 VS6

-0.98

<TS 2350 B

138 91 18 DBH 1.97

<TS 2351 B

138 91 16 VS7 1.07

<TS Table 4D Wear Indication Summary Diagonal Bar Wear Vertical Strap Wear I Eggcrate Wear

[ Foreign Object Wear Tubes Indications Tubes Indications Tubes Indications Tubes Indications SGA 175 184 473 787 1387 1949 3

3 SGB 131 137 515 842 1085 1372 1

2 3

152 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 5 Tube Plugging Summary by Damage Mechanism TUBE PLUGGING

SUMMARY

SG E-50A SG E-50B Wear-Vertical Straps 0

1 Wear-Diagonal Bar 0

0 Wear - Eggcrate 0

0 Wear-Loose Part 2

1 Wear-Dent 0

0 Wear - Tube to Tube (TBP) 0 0

Wear - Volumetric 0

0 Circumferential ODSCC TTS 5

2 Axial ODSCC TTS 1

2 Axial ODSCC Freespan Ding 0

0 Axial ODSCC Eggcrate & Vertical Strap 1

3 Axial ODSCC in Greater Than 5 Volt Dents 0

0 Axial ODSCC in Less Than 5 Volt Dents 0

0 Axial PWSCC Tubesheet 0

0 Circumferential PWSCC Tubesheet 0

0 Axial ODSCC in U-bend 0

0 Restricted Tube 0

0 Administrative 4

1 2014 Outage Total 13 10 Pre-service Tubes Plugged 308 309 Effective Tubes Plugged 537 446 Effective Tubes Plugged Percentage 6.5%

5.4%

SG Total Number of Tubes 8219 8219 153 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 6 Condition Monitoring Results Identification of Tubes Plugged (all conditions for tubes that were plugged in the 2014 refueling outage)

SG Row Column Location Reason For Plugging E-50A 23 118 01H-0.81 SAI No Stabilization E-50A 24 49 TSH+0.17 SCI Stabilization E-50A 33 52 TSH+0.38 SAI No Stabilization E-50A 40 51 TSH-0.11 SCl Stabilization E-50A 56 59 TSH-0.10 SCI Stabilization E-50A 76 79 TSH+0.11 SCI Stabilization E-50A 105 104 TSH+0.01 SCI Stabilization E-50A 132 73 ADMIN PTP Stabilization E-50A 133 74 TSH+0.01 SVI Stabilization E-50A 134 73 ADMIN PTP Stabilization E-50A 134 75 TSH+0.00 SVI Stabilization E-50A 135 74 ADMIN PTP Stabilization E-50A 136 75 ADMIN PTP Stabilization E-50B 3

112 ADMIN PTP No Stabilization E-50B 23 46 TSH+0.42 SAI No Stabilization E-50B 23 110 01H-0.23 SAI No Stabilization E-50B 28 51 TSH+0.1 1 SCI Stabilization E-50B 29 106 01H-0.28 SAI No Stabilization E-50B 74 75 TSH-0.09 SCI Stabilization E-50B 76 95 TSH+1.40 SAI No Stabilization E-50B 82 115 01H-0.97 SAI No Stabilization E-50B 108 35 TSC+0.00 SVI Stabilization E-50B 113 48 VS2-0.91 WAR (41%)

I_

I I

No Stabilization 154 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7A Steam Generator Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side 05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side 155 of 156

Steam Generator Tube Inspection Report for the 2014 Refueling Outage Table 7B Acronyms and Abbreviations Acronym Definition AVB Anti Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DDI Dent or Ding with Indication DSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AREVA Data Management System LP Loose Part MRPC Motorized Rotating Pancake Coil (+Pt. TM)

MBM Manufacturing Burnish Mark NDD No Degradation Detected NDE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWSCC Primary Water Stress Corrosion Cracking SAI Single Axial Indication SCI Single Circumferential Indication SVI Single Volumetric Indication TBP To Be Plugged TSP Tube Support Plate TTS Top of Tubesheet TW Through Wall

<TS Less Than Technical Specification WAR Wear Indication 156 of 156