ML16341A850: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 2: | Line 2: | ||
| number = ML16341A850 | | number = ML16341A850 | ||
| issue date = 10/24/2016 | | issue date = 10/24/2016 | ||
| title = | | title = 7 to Updated Final Safety Analysis Report, Chapter 5, Table 5.2-5 - Summary of Analyses-Jet Forces Impacting on Internal Structures. Page 1 of 2 | ||
| author name = | | author name = | ||
| author affiliation = Indiana Michigan Power Co | | author affiliation = Indiana Michigan Power Co | ||
| Line 17: | Line 17: | ||
=Text= | =Text= | ||
{{#Wiki_filter: | {{#Wiki_filter:IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: | ||
17 Table: | |||
5.2-5 Page: | |||
1 of 2 | |||
==SUMMARY== | ==SUMMARY== | ||
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL | OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft) | ||
23. | Critical Target Normal Operating Pressure Psia. | ||
# | Jet Effect Remarks Break #1 29"I.D. | ||
42.0(2)Operating | 614'-0" Note 1 (2) 2250 c | ||
# | #2 27.5"I.D. | ||
# | 614'-0" Note (1) (2) 2250 c | ||
# | #3 29"I.D. | ||
# | 615'-0"+ | ||
Encl 1020 d 1 Jet blocked; restraints prevent further movement. | 23.02 Crane Wall 2250 c | ||
#4 31"I.D. | |||
612'-9"+ | |||
37.0 (2) | |||
Operating Deck 2250 d | |||
#5 31"I.D. | |||
607'-9"+ | |||
42.0(2) | |||
Operating Deck 2250 d | |||
#6 27.5"I.D. | |||
614'-0" 11.0(2) | |||
Crane Wall 2250 d | |||
#7 29"I.D. | |||
615'-3+ | |||
39.5(2) | |||
Operating Deck 2250 c | |||
#8 31"I.D. | |||
607'-9"+ | |||
42.0(2) | |||
Operating Deck 2250 d | |||
#9 31"I.D. | |||
603-8 1/4 13.0(2) | |||
Crane Wall 2250 d | |||
#10 27.5"I.D. | |||
614'-0" 14.0 Crane Wall 2250 d | |||
#113 29"I.D. | |||
614'-0" 19.54 Crane Wall 2250 c | |||
#125 29"I.D. | |||
614'-0" 20.0 Crane Wall 2250 c | |||
#13 11"I.D. | |||
620'-0"+ | |||
6.0(4) | |||
Pressurizer Slab 2250 d | |||
#14 30"I.D. | |||
686'-10 3/16" 16.0 Steam Gen. | |||
Encl 1020 d | |||
1 Jet blocked; restraints prevent further movement. | |||
2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes. | 2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes. | ||
3 Surge line connection on loop 3 only. | 3 Surge line connection on loop 3 only. | ||
4 Unit 2 only. LBB accepted for Unit 1. | 4 Unit 2 only. LBB accepted for Unit 1. | ||
5 14 | 5 14 connection on loop 2 only. | ||
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: | |||
17 Table: | |||
5.2-5 Page: | |||
2 of 2 | |||
==SUMMARY== | ==SUMMARY== | ||
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL | OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft) | ||
Critical Target Normal Operating Pressure Psia. | |||
Jet Effect Remarks | |||
#15 28"I.D. | |||
635'-0" 4.0 Containment Wall 1020 d}} | |||
Latest revision as of 18:19, 9 January 2025
| ML16341A850 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 10/24/2016 |
| From: | Indiana Michigan Power Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16336A263 | List:
|
| References | |
| AEP-NRC-2016-42 | |
| Download: ML16341A850 (2) | |
Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
1 of 2
SUMMARY
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks Break #1 29"I.D.
614'-0" Note 1 (2) 2250 c
- 2 27.5"I.D.
614'-0" Note (1) (2) 2250 c
- 3 29"I.D.
615'-0"+
23.02 Crane Wall 2250 c
- 4 31"I.D.
612'-9"+
37.0 (2)
Operating Deck 2250 d
- 5 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
- 6 27.5"I.D.
614'-0" 11.0(2)
Crane Wall 2250 d
- 7 29"I.D.
615'-3+
39.5(2)
Operating Deck 2250 c
- 8 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
- 9 31"I.D.
603-8 1/4 13.0(2)
Crane Wall 2250 d
- 10 27.5"I.D.
614'-0" 14.0 Crane Wall 2250 d
- 113 29"I.D.
614'-0" 19.54 Crane Wall 2250 c
- 125 29"I.D.
614'-0" 20.0 Crane Wall 2250 c
- 13 11"I.D.
620'-0"+
6.0(4)
Pressurizer Slab 2250 d
- 14 30"I.D.
686'-10 3/16" 16.0 Steam Gen.
Encl 1020 d
1 Jet blocked; restraints prevent further movement.
2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes.
3 Surge line connection on loop 3 only.
4 Unit 2 only. LBB accepted for Unit 1.
5 14 connection on loop 2 only.
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
2 of 2
SUMMARY
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks
- 15 28"I.D.
635'-0" 4.0 Containment Wall 1020 d