Text
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
1 of 2
SUMMARY
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks Break #1 29"I.D.
614'-0" Note 1 (2) 2250 c
- 2 27.5"I.D.
614'-0" Note (1) (2) 2250 c
- 3 29"I.D.
615'-0"+
23.02 Crane Wall 2250 c
- 4 31"I.D.
612'-9"+
37.0 (2)
Operating Deck 2250 d
- 5 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
- 6 27.5"I.D.
614'-0" 11.0(2)
Crane Wall 2250 d
- 7 29"I.D.
615'-3+
39.5(2)
Operating Deck 2250 c
- 8 31"I.D.
607'-9"+
42.0(2)
Operating Deck 2250 d
- 9 31"I.D.
603-8 1/4 13.0(2)
Crane Wall 2250 d
- 10 27.5"I.D.
614'-0" 14.0 Crane Wall 2250 d
- 113 29"I.D.
614'-0" 19.54 Crane Wall 2250 c
- 125 29"I.D.
614'-0" 20.0 Crane Wall 2250 c
- 13 11"I.D.
620'-0"+
6.0(4)
Pressurizer Slab 2250 d
- 14 30"I.D.
686'-10 3/16" 16.0 Steam Gen.
Encl 1020 d
1 Jet blocked; restraints prevent further movement.
2 This break does not require consideration of Jet Forces since LBB methodology adopted. Maintained for historical purposes.
3 Surge line connection on loop 3 only.
4 Unit 2 only. LBB accepted for Unit 1.
5 14 connection on loop 2 only.
IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:
17 Table:
5.2-5 Page:
2 of 2
SUMMARY
OF ANALYSES-JET FORCES IMPACTING ON INTERNAL STRUCTURES Source Diameter Elevation Jet Travel (ft)
Critical Target Normal Operating Pressure Psia.
Jet Effect Remarks
- 15 28"I.D.
635'-0" 4.0 Containment Wall 1020 d