NG-17-0093, License Amendment Request (TSCR-168), Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:NEXTeraM ENERGY~
{{#Wiki_filter:}}
DUANE ARNOLD June 9, 2017                                                                                NG-17-0093 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, DC 20555 Duane Arnold Energy Center Docket No. 50-331 Renewed Facility Operating License No. DPR-49 License Amendment Request (TSCR-168), Application to Revise Technical Specifications to Adopt TSTF-542, "Reactor Pressure Vessel Water Inventory Control" Pursuant to 10 CFR 50.90, NextEra Energy Duane Arnold, LLC (NextEra) is submitting a request for an amendment to the Technical Specifications (TS) for the Duane Arnold Energy Center (DAEC). The proposed change replaces existing Technical Specifications requirements related to "operations with a potential for draining the reactor vessel" (OPDRVs) with new requirements on Reactor Pressure Vessel Water Inventory Control (RPV WIC) to protect Safety Limit 2.1.1.3.
Safety Limit 2.1.1.3 requires reactor vessel water level to be greater than the top of active irradiated fuel.
Attachment 1 provides a description and assessment of the proposed changes. Attachment 2 provides the existing TS pages marked to show the proposed changes. Attachment 3 provides revised (clean) TS pages. Attachment 4 provides existing TS Bases pages marked to show the proposed changes for information only.
NextEra requests approval of the proposed amendment by June 1, 2018. Once approved, the amendment shall be implemented within 90 days.
In accordance with 10 CFR 50.91, a copy of this application, with enclosures, is being provided to the designated State of Iowa official.
As discussed in Attachment 1, the proposed change does not involve a significant hazards consideration pursuant to 10 CFR 50.92, and there are no significant environmental impacts associated with the change. The DAEC Onsite Review Group has reviewed the proposed license amendment request.
This letter contains no new or revised regulatory commitments.
If you have any questions or require additional information, please contact J. Michael Davis, Licensing Manager, at 319-851-7032.
NextEra Energy Duane Arnold, LLC , 3277 DAEC Road, Palo, IA 52324
 
Document Control Desk NG-17-0093 Page 2of2 I declare under penalty of perjury that the foregoing is hue and correct.
Executed on June    J_, 2017
~'4(2 Dean Curtland Director, Site Operations N extEra Energy Duane Arnold, LLC Attachments: 1. Description and Assessment
: 2. Proposed Technical Specification Changes (Mark-Up)
: 3. Revised Technical Specification Pages
: 4. Proposed Technical Specification Bases Changes (Mark-Up) cc:    Regional Administrator, USNRC, Region III, Project Manager, USNRC, Duane Arnold Energy Center Resident Inspector, USNRC, Duane Arnold Energy Center A. Leek (State of Iowa)
 
NG-17-0093 Attachment 1 Page 1of7 ATTACHMENT 1- DESCRIPTION AND ASSESSMENT
 
==1.0 DESCRIPTION==
 
The proposed change replaces existing Technical Specifications (TS) requirements related to "operations which have the potential for draining the reactor vessel" (OPDRVs) with new requirements on Reactor Pressure Vessel Water Inventory Control (RPV WIC) to protect Safety Limit 2.1.1.3. Safety Limit 2.1.1.3 requires reactor vessel water level to be greater than the top of active irradiated fuel.
2.0 ASSESSMENT 2.1 Applicability of Published Safety Evaluation NextEra Energy Duane Arnold, LLC (NextEra) has reviewed the safety evaluation provided to the Technical Specifications Task Force (TSTF) on December 20, 2016, as well as the information provided in TSTF-542. NextEra has concluded that the justifications presented in TSTF-542 and the safety evaluation prepared by the NRC staff are applicable to the Duane Arnold Energy Center (DAEC) and justify this amendment for incorporation of the changes to the DAEC TS.
The following DAEC TS references are related to OPDRVs and are affected by the proposed change:
3.3.5.1    Emergency Core Cooling System (ECCS) Instrumentation 3.3.6.1    Primary Containment Isolation Instrumentation 3.3.6.2    Secondary Containment Isolation Instrumentation 3.3.7.1    Standby Filter Unit System Instrumentation 3.5.2      ECCS - Shutdown 3.6.1.3    Primary Containment Isolation Valves (PCIVs) 3.6.4.1    Secondary Containment 3.6.4.2    Secondary Containment Isolation Valves/Dampers (SCIV /Ds) 3.6.4.3    Standby Gas Treatment (SGT) System 3.7.4      Standby Filter Unit System (SFU) System 3.7.5      Control Building Chiller (CBC) System 3.8.2      AC Sources - Shutdown 3.8.5      DC Sources - Shutdown 3.8.8      Distribution Systems - Shutdown
 
NG-17-0093 Attachment 1 Page 2of7 2.2 Variations NextEra is proposing the following variations from the TS changes described in TSTF-542 or the applicable parts of the NRC staffs safety evaluation. These variations do not affect the applicability of TSTF-542 or the NRC staff's safety evaluation to the proposed license amendment.
: a. The DAEC TS utilize different numbering and titles than the Standard TS on which TSTF-542 was based. The table below shows the differences between the plant-specific TS numbering and titles and the TSTF-542 numbering and titles. These differences are administrative and do not affect the applicability ofTSTF-542 to the DAEC TS.
TSTF-542 TS Numbering and Titles                        DAEC TS Numbering and Titles TS 3.3.7.1    [Main Control Room                        TS 3.3.7.1 Standby Filer Unit (SFU) System Environmental Control (MCREC)]                        Instrumentation System Instrumentation TS 3.6.4.2    Secondary Containment Isolation          TS 3.6.4.2  Secondary Containment Isolation Valves (SCIVs)                                        Valves/Dampers(SCIV /Ds)
TS 3.7.4      [Main Control Room                        TS 3.7.4    Standby Filter Unit (SFU) System Environmental Control (MCREC)]
System TS 3.7.5      [ Control Room Air Conditioning          TS 3.7.5    Control Building Chiller (CBC)
(AC)] System                                          System TS 3.8.10    Distribution Systems - Shutdown          TS 3.8.8    Distribution Systems - Shutdown
: b. TS 3.5.2, Reactor Pressure Vessel Water Inventoty Control, in TSTF-542 includes a note regarding manual realignment to the low pressure coolant injection (LPCI) mode that modifies tlle limiting condition for operation (LCO). The note allows a required LPCI subsystem to be considered operable during alignment and operation for decay heat removal if capable of being manually realigned to the LPCI mode and not otl1envise inoperable. In the DAEC TS, the same note modifies surveillance requirement (SR) 3.5.2.4, which verifies that each power operated and automatic valve that is not locked, sealed or othe1wise secured in position is in its correct position, rather than the LCO. By modifying tl1e SR, the note allows a required LPCI subsystem to be considered operable during alignment and operation for decay heat removal if capable of being manually realigned to tlle LPCI mode and not otl1envise inoperable. While the location of the note in tlle DAEC TS is different from TSTF-542, tlle note se1ves the same purpose. Therefore, this difference has no effect on the adoption of TSTF-542 and is acceptable.
: c. TSTF-542 and the associated safety evaluation discuss the applicable regulatoty requirements and guidance, including the 10 CFR 50, Appendix A, General Design Criteria (GDC).
DAEC was not licensed to the 10 CFR 50, Appendix A, GDC. The DAEC Updated Final Safety Analysis Report, section 3.1, contains an evaluation of the DAEC design basis as measured against the AEC General Design Criteria (GDC) for nuclear power plants, Appendix A, of 10 CFR 50 effective May 21, 1971, and subsequently amended July 7, 1971.
 
NG-17-0093 Attachment 1 Page 3of7 This difference does not alter the conclusion that the proposed change is applicable to DAEC.
: d. The DAEC TS contain a Surveillance Frequency Control Program (SFCP). Therefore, the SR Frequencies for Specifications 3.3.5.2 and 3.5.2 are "In accordance with the Surveillance Frequency Control Program." For new SRs added by this proposed amendment, the SFCP will initially establish Frequencies consistent with those specified in TSTF-542.
: e. DAEC TS 3.6.1.3, PCIVs, is currently applicable in Modes 1, 2, and 3, and Modes 4 and 5 for the shutdown cooling system isolation valves when required by LCO 3.3.6.1, "Primary Containment Isolation Instrumentation." However, TSTF-542 deletes from Table 3.3.6.1-1 the Modes 4 and 5 requirement for shutdown cooling system isolation. As a result, TS 3.6.1.3 will no longer require any PCIVs to be operable in Modes 4 or 5. Therefore, NextEra proposes to revise tl1e Applicability to Modes 1, 2, and 3 and delete LCO Condition G, which is applicable in Modes 4 and 5, and the associated Required Actions from TS 3.6.1.3. In addition, the unnecessary reference to Modes 1, 2, or 3 in Condition Fis deleted since LCO 3.6.1.3 is applicable only in Modes 1, 2 and 3. These changes are administrative in nature and are justified on the basis that TSTF-542 removed the Mode 4 and 5 Applicability from LCO 3.6.1.3.
: f. DAEC does not have the capability to perform channel checks for the following functions in proposed Table 3.3.5.2-1, "RPV Water Inventoi-y Control Instrumentation": Function 1.a, "Reactor Steam Dome Pressure - Low (Injection Permissive),'' Function 1.b, "Core Spray Pump Discharge Flow -Low (Bypass),'' Function 2.a, "Reactor Steam Dome Pressure
    - Low (Injection Permissive)," and Function 2.b, "Low Pressure Coolant Injection Pump Discharge Flow - Low (Bypass)." The current TS do not include channel checks for these functions and sinlllarly, channel checks are not included for these functions in proposed Table 3.3.5.2-1.
: g. The DAEC LPCI system consists of two loops with two pumps in each loop. Function 2.f, "Low Pressure Coolant Injection Pump Discharge Flow - Low (Bypass)," in current TS Table 3.3.5.1-1 requires one operable channel per loop. NextEra proposes to include tl1e one channel per loop requirement for Function 2.b in proposed Table 3.3.5.2-1 rather than one channel per pump as included in TSTF-542 because each LPCI loop has only one flow instrument.
: h. DAEC current TS 3.6.4.1, "Seconda1y Containment," and TS 3.6.4.3, "Standby Gas Treatment System,'' are applicable in Modes 1, 2, and 3, and during OPDRVs. Consistent with TSTF-542, the applicability during OPDRVsis removed, so the TS applicability becomes Modes 1, 2, and 3. Condition A in TS 3.6.4.1 and Conditions Band Din TS 3.6.4.3 apply to conditions tliat occur in Modes 1, 2, and 3; e.g., secondary containment inoperable in Mode 1, 2, or 3. Since the applicability of these TS is changed to Modes 1, 2, and 3, it is no longer necessary for the Conditions to repeat the applicability. Therefore, NextEra proposes to remove the words "in MODE 1, 2, or 3" from Condition A in TS 3.6.4.1 and Conditions B and D in TS 3.6.4.3. This is an administrative change that does not affect the applicability ofTSTF-542 to the DAEC TS.
 
NG-17-0093 Attachment 1 Page 4of7
: 1. DAEC TS Table 3.3.5.1-1, "Emergency Core Cooling System Instrumentation," does not include functions for manual initiation of CS and LPCI. Since the design does not include this feature, proposed Table 3.3.5.2-1 does not include manual initiation functions for CS and LPCI. In addition, TS 3.3.5.2 does not include a surveillance requirement (SR) for a logic system functional test since the SR applies only to the manual initiation function.
Likewise, the changes to TS 3.5.2, RPV Water Inventmy Control, do not include SR 3.5.2.8, which demonstrates ECCS injection/ spray actuation on a manual initiation signal.
J*  DAEC TS LCO 3.3.6.1 currently requires Shutdown Cooling System (SDC) Isolation on reactor vessel water level-low in Modes 3, 4, and 5. TSTF-542 deletes tlle Modes 4 and 5 requirement for this function and includes tlus function in new TS 3.3.5.2 with an Applicability of "When automatic isolation of the associated penetration flow path(s) is credited in calculating DRAIN TIME." However, TS 3.3.6.1 retains tlle Applicability of Mode 3 for SDC Isolation to prevent tlus potential flow path from lowering the reactor vessel level to the top of the fuel in Mode 3.
The current TS 3.3.6.1 Required Actions for inoperability of this function are J.1, immediately initiate action to restore the channel to operable status; or J.2, inlmediately initiate action to isolate the Residual Heat Removal (RHR) Shutdown Cooling System.
TSTF-542 deletes Required Action J.2; however, NextEra proposes to retain Required Action J.2 to account for SDC system isolation in Mode 3. Since Required Action J.2 currently applies in Modes 3, 4, and 5 and TSTF-542 deletes only the Modes 4 and 5 applicability; retaining the Required Action for application in Mode 3 is appropriate.
The DAEC TS contain requirements that differ from the Standard Technical Specifications on which TSTF-542 was based, but are encompassed in the TSTF-542 justification:
* There are DAEC specific instrnmentation functions that differ from the Standard Technical Specifications (STS). DAEC TS Table 3.3.5.1-1 includes Functions 1.f and 2.k, 4.16 kV emergency bus sequential loading relay for tlle core spray (CS) and low-pressure coolant injection (LPCI) systems, which are applicable in Modes 1 through 5. These functions withhold the start permissive signal from the circuits that start the CS and LPCI pumps during accident conditions if an unde1voltage condition exists on an emergency bus. These functions are unnecessary for manual operation; therefore, the Modes 4 and 5 Applicability of these functions can be elinllnated because the ECCS subsystem required by TS 3.5.2 in Modes 4 and 5 is proposed to be started by manual operation.
DAEC TS Table 3.3.5.1-1 also includes Function 1.e, "Core Spray Pump Start Time Delay Relay,'' which is required in Modes 1 through 5. The purpose of the time delay relay is to stagger the start of the CS pumps to limit the transient on the 4.16 kV emergency buses, sinlllar to the purpose of the LPCI time delay relays in STS Table 3.3.5.1-1, Function 2.f.
Changes to this instrumentation function are justified by the discussion in Section 3.4.1 of the TSTF-542 justification. This staggering is unnecessary for manual operation of the ECCS subsystem required by TS 3.5.2 in Modes 4 and 5 ; therefore, the requirement for this function in Modes 4 and 5 can be removed from the TS.
 
NG-17-0093 Attachment 1 Page 5of7
 
==3.0 REGULATORY ANALYSIS==
 
3.1 No Significant Hazards Consideration Analysis NextEra Energy Duane Arnold, LLC (NextEra) requests adoption ofTSTF-542 "Reactor Pressure Vessel Water Inventory Control," which is an approved change to the Standard Technical Specifications (STS), into the Duane Arnold Energy Center Technical Specifications (TS). The proposed amendment replaces the existing requirements in the TS related to "operations with a potential for draining the reactor vessel" (OPDRVs) with new requirements on Reactor Pressure Vessel Water Inventory Control (RPV WIC) to protect Safety Li.nut 2.1.1.3. Safety Limit 2.1.1.3 requires reactor vessel water level to be greater than the top of active irradiated fuel.
NextEra has evaluated whether or not a significant hazards consideration is involved with the proposed amendment(s) by focusing on the three standards set forth in 10 CFR 50.92, "Issuance of amendment," as discussed below:
: 1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?
Response: No The proposed change replaces existing TS requirements related to OPDRVs with new requirements on RPV WIC that will protect Safety Limit 2.1.1.3. Draining of RPV water inventory in Mode 4 (i.e., cold shutdown) and Mode 5 (i.e., refueling) is not an accident previously evaluated and, therefore, replacing the existing TS controls to prevent or nlitigate such an event with a new set of controls has no effect on any accident previously evaluated.
RPV water inventmy control in Mode 4 or Mode 5 is not an initiator of any accident previously evaluated. The existing OPDRV controls or the proposed RPV WIC controls are not nlitigating actions assumed in any accident previously evaluated.
The proposed change reduces the probability of an unexpected draining event (which is not a previously evaluated accident) by imposing new requirements on the limiting time in which an unexpected draining event could result in the reactor vessel water level dropping to the top of the active fuel (TAF). These controls require cognizance of the plant configuration and control of configurations with unacceptably short drain times. These requirements reduce the probability of an unexpected draining event. The current TS requirements are only nlitigating actions and impose no requirements that reduce the probability of an unexpected draining event.
The proposed change reduces the consequences of an unexpected draining event (which is not a previously evaluated accident) by requiring an Emergency Core Cooling System (ECCS) subsystem to be operable at all times in Modes 4 and 5. The current TS requirements do not require any water injection systems, ECCS or othenvise, to be Operable in certain conditions in Mode 5. The change in requirement from two ECCS subsystems to one ECCS subsystem in Modes 4 and 5 does not significantly affect the consequences of an unexpected draining event because the proposed Actions ensure equipment is available within the linUting drain time that is
 
NG-17-0093 Attachment 1 Page 6of7 as capable of mitigating the event as the current requirements. The proposed controls provide escalating compensatoq measures to be established as calculated drain times decrease, such as verification of a second method of water injection and additional confirmations that containment and/ or filtration would be available if needed.
The proposed change reduces or eliminates some requirements that were determined to be unnecessary to manage the consequences of an unexpected draining event, such as automatic initiation of an ECCS subsystem and control room ventilation. These changes do not affect the consequences of any accident previously evaluated since a draining event in Modes 4 and 5 is not a previously evaluated accident and the requirements are not needed to adequately respond to a draining event.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
: 2. Does the proposed amendment create the possibility of a new or different kind of accident from any previously evaluated?
Response: No The proposed change replaces existing TS requirements related to OPDRVs with new requirements on RPV WIC that will protect Safety Limit 2.1.1.3. The proposed change will not alter the design function of the equipment involved. Under the proposed change, some systems that are currently required to be operable during OPDRVs would be required to be available witliin the limiting drain time or to be in service depending on the limiting drain time. Should those systems be unable to be placed into service, the consequences are no different than if those systems were unable to perform their function under the current TS requirements.
The event of concern under the current requirements and tl1e proposed change is an unexpected draining event. The proposed change does not create new failure mechanisms, malfunctions, or accident initiators that would cause a draining event or a new or different kind of accident not previously evaluated or included in the design and licensing bases.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.
: 3. Does the proposed amendment involve a significant reduction in a margin of safety?
Response: No The proposed change replaces existing TS requirements related to OPDRVs with new requirements on RPV WIC. The current requirements do not have a stated safety basis and no margin of safety is established in the licensing basis. The safety basis for the new requirements is to protect Safety Limit 2.1.1.3. New requirements are added to determine the limiting time in which the RPV water invento1y could drain to the top of the fuel in tl1e reactor vessel should an unexpected draining event occur. Plant configurations that could result in lowering the RPV
 
NG-17-0093 Attachment 1 Page 7of7 water level to the TAF within one hour are now prohibited. New escalating compensatory measures based on the limiting drain time replace the current controls. The proposed TS establish a safety margin by providing defense-in-depth to ensure that the Safety Limit is protected and to protect the public health and safety. While some less restrictive requirements are proposed for plant configurations with long calculated drain times, the overall effect of the change is to improve plant safety and to add safety margin.
Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, NextEra concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.
4.0 ENVIRONMENTAL EVALUATION The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or smveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.
 
ATTACHMENT 2 to NG-17-0093 Proposed Technical Specification Changes (Mark-Up) 46 Pages Follow
 
Definitions 1.1 1.1 Definitions (continued)
CORE OPERATING LIMITS      The COLR is the unit specific document that provides REPORT (COLR)              cycle specific parameter limits for the current reload cycle.
These cycle specific limits shall be determined for each reload cycle in accordance with Specification 5.6.5. Plant operation within these limits is addressed in individual Specifications.
DOSE EQUIVALENT 1-131        DOSE EQUIVALENT 1-131 shall be that concentration of 1-131 (microcuries/ml), that alone would produce the same dose as the quantity and isotopic mixture of            1 1-131, 1-132, 1-133, 1-134, and 1-135 actually present.
The dose conversion factors used for this calculation          {'
shall be those listed in Federal Guidance Report (FGR) 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion," 1989 and FGR 12, "External Exposure to Radionuclides in Air, Water, and Soil," 1993.
!INSERT 1 !--7 END OF CYCLE                The EOC RPT SYSTEM RESPONSE TIME shall be that RECIRCULATION PUMP          time interval from initial signal generation by the TRIP (EOC RPT) SYSTEM      associated turbine stop valve limit switch or from when RESPONSE TIME              the turbine control valve hydraulic oil control oil pressure drops below the pressure switch setpolnt to actuation of the breaker secondary (auxiliary) contact. The response time may be measured by means of any series of sequential, overlapping, or total steps so that the entire response time is measured.
(continued)
DAEC                                1.1-3                            Amendment ~
 
INSERT1 DRAIN TIME The DRAIN TIME is the time It would take for the water inventory in and above the Reactor Pressure Vessel (RPV) to drain to the top of the active fuel (TAF) seated in the RPV assuming:
a)    The water inventory above the TAF is divided by the limiting drain rate; b)    The limiting drain rate is the larger of the drain rate through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g., seismic event, loss of normal power, single human error), for all penetration flow paths below the TAF except:
: 1. Penetration flow paths connected to an intact closed system, or isolated by manual or automatic valves that are locked, sealed, or otherwise secured In the closed position, blank flanges, or other devices that prevent flow of reactor coolant through the penetration flow paths;
: 2.      Penetration flow paths capable of being isolated by valves that will close automatically without offslte power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation Instrumentation; or
: 3.      Penetration flow paths with isolation devices that can be closed prior to the RPV water level being equal to the TAF by a dedicated operator trained in the task, who is in continuous communication with the control room, is stationed at the controls, and is capable of closing the penetration flow path isolation device without offsite power.
c)    The penetration flow paths required to be evaluated per paragraph b) are assumed to open Instantaneously and are not subsequently isolated, and no water is assumed to be subsequently added to the RPV water inventory; d)    No additional draining events occur; and e)    Realistic cross-sectional areas and drain rates are used.
A bounding DRAIN TIME may be used in lieu of a calculated value.
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION                      COMPLETION TIME
: 8. As required by      8.1 --------------NOTES----------
Required Action A.1        1. Only applicable in and referenced in              MOOEg 1, 2, and Table 3.3.5.1 -1                3:-
2-:  Only applicable for Functions 1.a, 1.b, 2.a, and 2.b.
Declare supported                  1 hour from discovery of feature(s) inoperable            loss of initiation when redundant                    capability for feature(s) feature(s) ECCS                  in two or more low Initiation capability Is          pressure ECCS inoperable.                      subsystems AND
: 8. 2 --------------N 0 TE------------
On ly applicable for Functions 3.a and 3.b.
Declare High Pressure            1 hour from discovery of Coolant Injection (HPCI)          loss of HPCI initiation System inoperable.                capability 8.3  Place channel in trip.            24 hours (continued)
DAEC                          3.3-33                                Amendment ~
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION              REQUIRED ACTION                  COMPLETION TIME C. As required by      C.1 ------------NOTEg.. ________ _
Required Action A.1      1. Only applicable in and referenced in              MODES 1, 2, and Table 3.3.5.1-1.              3:-
                              ~    Only applicable for Functions 1.c, 1.e, 2.c and 2.e.
Declare supported              1 hour from feature(s) inoperable.          discovery of loss of initiation capability for two or more low pressure ECCS subsystems AND C.2 -------------NOTES-------
: 1. Only applicable in Modes 1, 2, and 3.
                            ~    Only applicable for Functions 2.g, 2.h, 2.1, and 2.j.
Declare Low Pressure            1 hour from Coolant Injection              discovery of loss of (LPCI) subsystem                Loop Selection inoperable.                    capability C.3 Restore channel to              24 hours OPERABLE status.
(continued)
DAEC                        3.3-34                                Amendment ~
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION                      COMPLETION TIME E. As required by      E.1  ----------NOTES---------
Required Action A.1        1. ORiy a1313lisal:lls iR and referenced in              MODES 1, 2, aRd Table 3.3.5.1 -1.              ~
fr.. Only applicable for Functions 1.d and 2.f.
Declare supported                1 hour from discovery of feature(s) inoperable.          loss of initiation capability for two or more minimum flow valves In the low pressure ECCS subsystems AND E.2  Restore channel t_    o        7 days OPERABLE status.
F. As required by      F.1  Restore channel to                1 hour Required Action A.1      OPERABLE status.
and referenced in Table 3.3.5.1-1.
(continued)
DAEC                          3.3-36                              Amendment ~
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1 -1(page1 of5)
Emergency Core Cooling System Instrumentation APPLICABLE                            CONDITIONS MODES          REQUIRED          REFERENCED OR OTHER        CHANNELS                FROM SPECIFIED            PER              REQUIRED            SURVEILLANCE              ALLOWABLE FUNCTION                CONDITIONS        FUNCTION            ACTIONA.1            REQUIREMENTS              VALUE
: 1. Core Spray System
                                                            ")
: a. Reactor Vessel Water              1,2,3,                                  B            SR  3.3.5.1.1      ?. 36.3 Inches Level - Low Low Low                                                                    SR  3.3.5.1.3 4~&(al                                                  SR  3.3.5.1.6 SR  3.3.5.1.9
: b. Drywell Pressure -                1,2,3            4(b)                B              SR 3.3.5.1.3      ~  2.19 pslg High                                                                                  SR 3.3.5.1.6 SR 3.3.5.1 .9
: c. Reactor Steam Dome              1,2,3              4                  c              SR 3.3.5.1 .3    ?. 363.3 psig Pressure - Low                                                                          SR 3.3.5.1.6      and ~ 465.1 psig (Injection Permissive)                                                                  SR 3.3.5.1.9 4~&(al                4                  B              SR 3.3.IU .3      .. 363.3 Jl6l!'I SR 3.3.li .U SR 3.3.li .1.Q    aREI < 481i .1 iislg
: d. Core Spray Pump                  1,2,3,          1 per                  E              SR 3.3.5.1.3      ?.256.6 gpm Discharge Flow - Low                            pump                                  SR 3.3.5.1 .6    and 4~&(al (Bypass)                                                                              SR 3.3.5.1.9      ~2362.1    gpm
: e. Core Spray Pump Start            1,2,3,          1 per                  c              SR 3.3.5.1.6      ?. 2.6 seconds Time Delay Relay                                pump                                  SR 3.3.5.1.9      and ~ 6.6 seconds 4~&(al
: f. 4.16 kV Emergency Bus            1,2,3,          1 per                  F              SR 3.3.5.1.5      ~3500V Sequential Loading                              pump                                  SR 3.3.5.1 .6 Relay 4~i(al SR 3.3.5.1 .9
: 2. Low Pressure Coolant Injection (LPCI) System
: a. Reactor Vessel Water            1,2,3,              4                  B              SR 3.3.5.1 .1    ?. 36.3 Inches Level- Low Low Low                                                                    SR 3.3.5.1 .3 4~&(a)                                                  SR 3.3.5.1 .6 SR 3.3.5.1.9
: b. Drywell Pressure -                1,2,3              4                  B              SR 3.3.5.1.3      ~  2.19 psig High                                                                                  SR 3.3.5.1.6 SR 3.3.5.1.9 continued
!a) WlleR asseelaleEI ECCS s111lsyslem!s) are re1111lr0EI le Ile OPER.'1,QbE Jl0F bCO 3.li.:!, ECCS Sl!Yllle*NR .
(b) Also required to Initiate the associated Diesel Generator (DG).
~
DAEC                                                                3.3-41                                            Amendment ~
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 2 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                              CONDITIONS MODES            REQUIRED        REFERENCED OR OTHER              CHANNELS              FROM SPECIFIED                PER            REQUIRED            SURVEILLANCE          ALLOWABLE FUNCTION                            CONDITIONS            FUNCTION          ACTION A.1          REQUIREMENTS          VALUE
: 2. LPCI System (continued)
: c. Reactor Steam Dome                                1,2,3                4                  c              SR 3.3.5.1.3    ,:: 363.3 pslg and Pressure - Low                                                                                          SR 3.3.5.1.8    !: 485.1 pslg (Injection Permissive)                                                                                  SR 3.3.5.1.9
                                                                                                                                ,:! 363.3 JlSi!j 4                  B              SR 3.:UA .3    aREI  ~ 489.1 JlSi!l SR 3.3.li .1.8 SR 3.3.5.1.Q
: d. Reactor Vessel Shroud                            1,2,3                4                  B            SR  3.3.5.1.1    ,:: -40.89 inches Level- Low                                                                                              SR  3.3.5.1.2 SR  3.3.5.1.4 SR  3.3.5.1.9
: e. Low Pressure Coolant                                                1 per                c            SR 3.3.5.1 .8 Injection Pump                                                      pump                              SR 3.3.5.1.9 Start - Time Delay Relay Pumps A& B                                                                                                              ,:: 8.8 seconds and
                                                                                                                              !: 11 .2 seconds
                                                                                                                              ,:: 13.8 seconds Pumps C & D                                                                                                              and
                                                                                                                              !: 33.5 seconds
: f. Low Pressure                                                          1 per                E            SR 3.3.5.1 .3  ,::471.8 gpm Coolant Injection Pump                                                loop                              SR 3.3.5.1.8    and Discharge Flow - Low                                                                                    SR 3.3.5.1.9    !: 3676.6 gpm (Bypass)
: g. LPCI Loop Select-                                1,2,3                4                  c            SR  3.3.5.1.1  ,:: 112.65 Inches Reactor Vessel Water                                                                                    SR  3.3.5.1.2 Level - Low-Low                                                                                        SR  3.3.5.1.6 SR  3.3.5.1.9
: h. LPCI Loop Select -                                1,2,3                4                  c            SR 3.3.5.1.2    ,:: 887 psig Reactor Steam Dome                                                                                      SR 3.3.5.1.4 Pressure - Low                                                                                          SR 3.3.5.1 .9 (continued)
(a) WlleA assaelateEI EGGS si,illsysteFR(S) aFe Feqi,iJreEI ta Ile OPERABLE JleF LGO 3.9.2, EGGS    Sll!JIEIB'HA.
DAEC                                                                3.3-42                                                    Amendment ~
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1(page3 of5)
Emergency Core Cooling System Instrumentation APPLICABLE                            CONDITIONS MODES OR            REQUIRED      REFERENCED OTHER              CHANNELS            FROM SPECIFIED                PER          REQUIRED        SURVEILLANCE            ALLOWABLE FUNCTION                          CONDITIONS            FUNCTION        ACTION A.1      REQUIREMENTS            VALUE
: 2. LPCI System (continued)
: i. LPCI Loop Select -                            1,2,3              4 per              c          SR    3.3.5.1.1  :s 7.8 psid Recirculation Pump                                                pump                          SR    3.3.5.1 .2 Differential Pressure                                                                          SR    3.3.5.1 .8 SR    3.3.5.1 .9 j . LPCI Loop Select -                            1,2,3                4                c          SR    3.3.5.1 .1  .:: 0.13 psid Recirculation Riser                                                                            SR    3.3.5.1.2        :s and 2.07 psid Differential Pressure                                                                          SR    3.3.5.1.4 SR    3.3.5.1.9
: k. 4.16 kV Emergency Bus                        1,2,3                  2                F          SR 3.3.5.1 .5    :s 3500 v Sequential Loading                                                                            SR 3.3.5.1.6 Relay                                                                                          SR 3.3.5.1.9 SR 3.:H.1.ii SR J .J .5.1.6 SR J .3.5.1.9
: 3. High Pressure Coolant Injection (HPCI) System
: a. Reactor Vessel Water                                                  4                B          SR  3.3.5.1.1  .:: 112.65 inches Level - Low Low                                                                                SR  3.3.5.1.3 SR  3.3.5.1.6 SR  3.3.5.1.9
: b. Drywell Pressure -                                                    4                B          SR 3.3.5.1.3    :s 2.19 psig High                                                                                            SR 3.3.5.1 .6 SR 3.3.5.1.9
: c. Reactor Vessel Water                                                  2                c          SR  3.3.5.1.1  :s 214.6 Inches Level- High                                                                                    SR  3.3.5.1 .3 SR  3.3.5.1.6 SR  3.3.5.1.9
: d. Condensate Storage                                                    2                D          SR 3.3.5.1.3    .:: 11.6 Inches Tank Level - Low                                                                                SR 3.3.5.1.6 SR 3.3.5.1.9 (continued)
(a) WheR tfole asseslateEI eCCS s111lsyslem(s) are re(jllirea te Ile OPERABblO per bCO J .5.2, eCCS S"111IElewfl.
(e) Wilh reactor steam dome pressure> 150 pslg.
~
DAEC                                                                3.3-43                                              Amendment~
 
ECCS Instrumentation 3.3.5.1 Table 3.3. 5.1-1 (page 4 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                            CONDITIONS MODES OR          REQUIRED          REFERENCED OTHER          CHANNELS                FROM SPECIFIED              PER            REQUIRED    SURVEILLANCE              ALLOWABLE FUNCTION                        CONDITIONS        FUNCTION            ACTION A.1  REQUIREMENTS              VALUE
: 3. HPCI System (continued)
: e. Suppression Pool                            1,                  2                  D    SR 3.3.5.1.3        .::: 5.9 inches Water Level - High                                                                    SR 3.3.5.1.6 2<9. 3!Gl                                      SR 3.3.5,1.9
: f. High Pressure Coolant Injection Pump                                                                    E    SR 3. 3.5.1.3      :::_ 264 .2 gpm Discharge Flow - Low                                                                    SR 3.3.5.1 .6        and (Bypass)                                                                                SR 3.3.5.1.9        .::: 2025.1 gpm
: 4. Automatic Depressurization System (ADS) Trip Logic A
: a. Reactor Vessel Water                                            2                  G    SR  3.3.5.1 .1    :::_ 36.3 inches Level - Low Low Low                                                                      SR  3.3.5.1.3 SR  3.3.5.1.6 SR  3.3.5.1.9
: b. Automatic                                                                          H    SR 3. 3.5.1.3      .::: 125 seconds Depressurization                                                                        SR 3.3.5.1 .6 System Timer                                                                            SR 3.3.5.1.9
: c. Reactor Vessel Water                                                                G    SR 3.3.5.1.1      :::_ 166.1 inches Level -Low                                                                              SR 3.3.5.1.3 (Confirmatory)                                                                          SR 3.3.5.1.6 SR 3.3.5.1.9
: d. Core Spray Pump                                                  2                  H    SR 3.3.5.1.3      :::_ 114.2 psig Discharge                                                                                SR 3.3.5.1.6      and Pressure - High                                                                          SR 3.3.5.1.9      .::: 177.0 psig
: e. Low Pressure Coolant                                            4                  H    SR 3.3.5.1 .3    :::_ 103.6 psig Injection Pump                                                                          SR 3.3.5.1 .6      and Discharge Pressure -                                                                    SR 3.3.5.1.9      .::: 147.o psig High (continued)
~s)  With reactor steam dome pressure > 150 psig.
~ '"'h re~O* *00om do~        P'M"" > 100 P**
DAEC                                                        3.3-44                                            Amendment            Ne:~
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 5 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                        CONDITIONS .
MODES OR        REQUIRED        REFERENCED OTHER        CHANNELS              FROM SPECIFIED          PER            REQUIRED    SURVEILLANCE              ALLOWABLE FUNCTION                        CONDITIONS      FUNCTION          ACTION A.1    REQUIREMENTS              VALUE
: 5. ADS Trip Logic B
: a. Reactor Vessel Water                                          2                G      SR  3.3.5.1.1      :::_ 38.3 inches Level - Low Low Low                                                                    SR  3.3.5.1.3 SR  3.3.5.1.8 SR  3.3.5.1 .9
: b. Automatic                                                                      H      SR 3.3.5.1.3      ::: 125 seconds Depressurization                                                                      SR 3.3.5.1.8 System Timer                                                                          SR 3.3.5.1 .9
: c. Reactor Vessel Water                                                            G      SR  3.3.5.1.1      :::_ 166.1 inches Level- Low                                                                              S_E 3.3.5.1.3 (Confirmatory)                                                                          SR  3".3i5.1.8 SR  3.3.5.1.9
: d. Core Spray Pump                                              2                  H      SR 3.3.5.1.3      :::_ 114.2 psig Discharge                                                                              SR 3.3.5.1 .8      and Pressure - High                                                                        SR 3.3.5.1.9      ::: 177.0 psig
: e. Low Pressure Coolant                                        4                  H      SR 3.3.5.1.3      :::_ 103.8 psig Injection Pump                                                                          SR 3.3.5.1.8      and
* Discharge                                                                              SR 3.3.5.1.9      ::: 147.0 psig Pressure - High (6) With reactor steam dome pressure > 100 psig.
1'
@]
DAEC                                                        3.3-45                                            Amendment -Ne:-~
 
RPV Water Inventory Control Instrumentation 3.3.5.2 3.3 INSTRUMENTATION 3.3.5.2    Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation LCO 3.3.5.2    The RPV Water Inventory Control instrumentation for each Function in Table 3.3.5.2-1 shall be OPERABLE.
APPLICABILITY:        According to Table 3.3.5.2-1.
ACTIONS
--------------------------------------NOTE----------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                    REQUIRED ACTION                COMPLETION TIME A One or more channels        A.1      Enter the Condition          Immediately inoperable.                        referenced in Table 3.3.5.2-1 for the channel.
B. As required by Required    B.1      Declare associated          Immediately Action A.1 and                      penetration flow path(s) referenced in                      incapable of automatic Table 3.3.5.2-1.                    isolation.
AND B.2    Calculate DRAIN TIME.        Immediately C. As required by Required    C.1    Place channel in trip.        1 hour Action A.1 and referenced in Table 3.3.5.2-1.
D. As required by Required    D.1    Restore channel to            24 hours Action A.1 and                      OPERABLE status.
referenced in Table 3.3.5.2-1.
DAEC                                        3.3.5.2-1                            Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 ACTIONS (continued)
CONDITION                      REQUIRED ACTION                COMPLETION TIME E. Required Action and          E.1    Declare associated low      Immediately associated Completion                pressure ECCS Time of Condition C or D            injection/spray subsystem not met.                            inoperable.
SURVEILLANCE REQUIREMENTS
----------------------------------------NOTE----------------------------------------
Refer to Table 3.3.5.2-1 to determine which SRs apply for each ECCS Function.
SURVEILLANCE                                    FREQUENCY SR 3.3.5.2.1        Perform CHANNEL CHECK.
In accordance with the Surveillance Frequency Control Program SR 3.3.5.2.2        Perform CHANNEL FUNCTIONAL TEST.                    In accordance with the Surveillance Frequency Control Program DAEC                                        3.3.5.2-2                            Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 Table 3.3.5.2-1 (page 1 of 1)
RPV Water Inventory Control Instrumentation APPLICABLE                  CONDITIONS MODES      REQUIRED      REFERENCED OR OTHER    CHANNELS          FROM SPECIFIED        PER        REQUIRED          SURVEILLANCE          ALLOWABLE FUNCTION              CONDITIONS    FUNCTION      ACTIONA.1          REQUIREMENTS              VALUE
: 1. Core Spray System                                                                                              I
: a. Reactor Steam Dome        4, 5            4              c            SR 3.3.5.2.2          s485.1 psig A'essure - Low (Injection Pernissive)
: b. Core Spray Pump          4, 5          1 per            D            SR 3.3.5.2.2          <: 256.6 gpm Discharge Flow - Low                  pump( a)                                                    and (Bypass)                                                                                  s 2382.1  gpm
: 2. Low A'essure Coolant Injection (LFCI) System
: a. Reactor Steam Dome        4, 5            4              c            SR 3.3.5.2.2      s 485.1    psig A'essure - Low (Injection Pernissive)
: b. Low A'essure              4, 5          1 per            D            SR 3.3.5.2.2        <: 471.8 gpm Coolant Injection                      loop( a)                                          and Pump Discharge Flow                                                                        s 3676.6 gpm
              *Low (Bypass)
: 3. RHR System Isolation
: a. Reactor VesselWater        (b)    2 in one trip          B            SR 3.3.5.2.1      <: 165.6 inches Level* Low                            system                          SR 3.3.5.2.2
: 4. Reactor Water Cleanup (RWCU) System Isolation
: a. Reactor VesselWater        (b)      2 in one trip        B            SR 3.3.5.2.1      <: 112.65 Level
* Low Low,                      system                          SR 3.3.5.2.2      inches (a) Associated with an ECCS subsystem required to be OPERABLE by LCO 3.5.2, "Reactor A'essure Vessel Water Inventory Control."
(b) When automatic isolation of the associated penetration flow path(s) is credited in calculating DRAIN TIME.
DAEC                                                3.3.5.2-3                                          Amendment
 
RCIC System Instrumentation 3.3.5.i 0 3.3 INSTRUMENTATION 3.3.5.~  Reactor Core Isolation Cooling (RCIC) System Instrumentation LCO    3.3.5.~          The RCIC System instrumentation for each Function in Table
            ~:!.-1 shall be OPERABLE.
APPLICABILITY:            MODE 1, MODES 2 and 3 with reactor steam dome pressure> 150 psig.
ACTIONS
-------------------------------------------------NOTE------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                            REQUIRED ACTION                  COMPLETION TIME A.      One or more channels                A.1    Enter the Condition          Immediately inoperable.                              referenced In Table 3 . 3.5.~ 1 for the channel.
B. As required by                              eclare RCIC                1 hour from discovery Required Action A.1                        System inoperable.          of loss of RCIC and reference In                                                        initiation capability Table 3.3.5.~- .
24 hours B.2    Place channel in trip.
(continued)
DAEC                                            3.3-46                              Amendment ~
 
RCIC System Instrumentation 3.3.5 .~
ACTIONS (continued) 0 CONDITION              REQUIRED ACTION                    COMPLETION TIME C. As required by        C.1    Restore channel to            24 hours Required Action A.1            OPERABLE status.
and referenced in Table 3.3.5.~
3 D. Asreq~d Action A.1 nd D.1    -----------NOTE---------
Only applicable If referen    din Table          RCIC pump suction is 3.3.5.~ 1.                    not aligned to the suppression pool.
Declare RCIC                  1 hour from discovery of System Inoperable.            loss of RCIC suction transfer capability AND 24 hours D.2.1  Place channel In trip.
OR 24 hours D.2.2 Align RCIC pump suction to the suppression pool.
E. Required Action and    E.1    Declare RCIC                  Immediately associated Completion          System inoperable.
Time of Condition B, C, or D not met.
DAEC                              3.3-47                              Amendment ~
 
RCIC System Instrumentation 3.3.5~
SURVEILLANCE REQUIREMENTS                                                                      lD
-----------------------------------~------N()TES--------------------------------------------------
: 1. Refer to Table    3.3.5.~ 1  to determine which SRs apply for each RCIC Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours for Functions 2 and 3; and (b) for up to 6 hours for Function 1 provided the associated Function maintains RCIC initiation capability.
SURVEILLANCE                              FREQUENCY SR 3.3.5.;?;.1              Perform CHANNEL CHECK.                      In accordance with the Surveillance Frequency Control Program Perform CHANNEL FUNCTIONAL TEST.            In accordance with the Surveillance Frequency Control Program Perform CHANNEL CALIBRATION.                In accordance with the Surveillance Frequency Control Program Perform CHANNEL CALIBRATION.                In accordance with the Surveillance Frequency Control Program SR 3.3.5.;?;.5            Perform LOGIC SYSTEM FUNCTIONAL              In accordance with TEST.                                        the Surveillance Frequency Control Program DAEC                                        3.3-48                        Amendment ~
 
RCIC System Instrumentation 3.3.5. ~
Table 3.3.5.:1,-1 (page 1 of 1)
Reactor Core Isolation Cooling System Instrumentation
                                                                                                                      \J CONDITIONS REQUIRED            REFERENCED CHANNELS        FROM REQUIRED                SURVEILLANCE        ALLOWABLE FUNCTION        PER FUNCTION            ACTIONA.1              REQUIREMENTS        VALUE
: 1. Reactor Vessel Water          4                    B                    SR 3.3.5.2.1  ?: 112.65 inches Level - Low Low                                                          SR 3.3.5.2.2 SR 3.3.5.2.3 SR 3.3.5.2.5                    SR 3.3.5.3.1
: 2. Reactor Vessel Water          2                    c                    SR 3.3.5.2.1  ~ 214.8 Inches  SR 3.3.5.3.2 Level - High                                                            SR 3.3.5.2.2 ~------iSR 3.3.5.3.3 SR 3.3.5.2.3 SR 3.3.5.2.5                    SR 3.3.5.3.5
: 3. Condensate Storage Tank      2                    D                    SR 3.3.5.2.2 Level- Low                                                              SR 3.3.5.2.4 SR 3.3.5.2.5 DAEC                                          3.3-49                                              Amendment ~
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 5 of 5)
Primary Containment Isolation Instrumentation APPLICABLE                                CONDITIONS MODES OR              REQUIRED          REFERENCED OTHER              CHANNELS                FROM SPECIFIED              PER TRIP          REQUIRED                SURVEILLANCE        ALLOWABLE FUNCTION                                CONDITIONS                SYSTEM            ACTIONC .1              REQUIREMENTS        VALUE
: 5. Reactor Water Cleanup (RWCU) System Isolation
: a. Differential Flow*                                    1,2,3                                        F                SR  3.3.6.1.2  .::: 59 gpm High                                                                                                                SR  3.3.6.1.4 SR 3.3.6.1.8 SR 3.3.6.1.9
: b. Area Temperature* High                                1,2,3                                        F                SR 3.3.6.1.2  _::: 133.3&deg;F SR 3.3.6.1.4 SR 3.3.6.1 .8 SR 3.3.6. 1.9
: c. Area Ventilation                                      1,2,3                                        F                SR 3.3.6.1.2 Differential                                                                                                        SR 3.3.6.1.4 Temperature - High                                                                                                  SR 3.3.6.1.6 SR 3.3.6.1.9 RWCU    Pump Room                                                                                                                  _::: 22.5&deg;F RWCU    Pump A Room                                                                                                                .::; 23.5&deg;F RWCU    Pump B Room                                                                                                              .::; 34 .5&deg;F RWCU    Heat Exch. Room                                                                                                            _.:::51 .5&deg;F d . SLC System Initiation                                  1,2                                                          SR 3.3.6.1.9    NA
: e. Reactor Vessel Water                                  1,2,3                                        F                SR  3.3.6 .1.1  > 112.65 Level - Low Low                                                                                                    SR  3.3.6.1.4  inches SR  3.3.6.1.7 SR  3.3.6.1.9
: f. Area Near TIP Room                                    1,2,3                                        F                SR  3.3.6.1.2  .::; 115.7&deg;F Ambient Temperature -                                                                                              SR  3.3.6.1.4 High                                                                                                                SR  3.3.6.1.6 SR  3.3.6.1.9
: 6. Shutdown Cooling System Isolation a . Reactor Steam Dome                                    1,2,3                                        F                SR 3.3.6.1.4  .::: 152.7 psig Pressure
* High                                                                                                    SR 3.3.6.1.5 SR 3.3.6.1.9
: b. Reactor Vessel Water                                  3,4;&                                        J                SR  3.3.6.1.1  ?. 165.6 inches Level-Low                                                                                                          SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9
: c. Drywall Pressure -                                    1,2,3                  2                    F                SR 3.3.6.1.4  _:::2.2 psig High                                                                                                                SR 3.3.6.1.8 SR 3.3.6.1.9
: 7. Containment Cooling System Isolation
: a. Containment Pressure -                                1,2,3                  4                    K                SR 3.3.6.1.3  ?.1 .25 psig High                                                                                                                SR 3.3.6.1.8 SR 3.3.6.1.9 (d) Each Trip System must have either an OPERABLE Function 5.b or an OPERABLE Function 5.c channel in both the RWCU pump area and in the RWCU heat exchanger area .
(e) SLC System Initiation only Inputs into one of the two trip systems.
(fj ORiy BAB lri11 sysleffl FBEjljifeEI iR MOE:llOS 4 aREI Ii WilBR Rl-IR SJl!jlEIB'.YR CBBliR!j Sysleffl iRIS!JFily RlaiRlalRBEI.
DAEC                                                                      3.3-61                                                            Amendment ~
 
Secondary Containment Isolation Instrumentation 3.3.6.2 Table 3.3.6.2-1 (page 1 of 1)
Secondary Containment Isolation Instrumentation APPLICABLE MODES OR            REQUIRED OTHER            CHANNELS SPECIFIED                PER              SURVEILLANCE        ALLOWABLE FUNCTION                      CONDITIONS          TRIP SYSTEM            REQUIREMENTS        VALUE
: 1. Reactor Vessel Water                        1,2,3,                2            SR  3.3.6.2.1        .:: 165.6 inches Level- Low                                  w                                  SR SR 3.3.6.2.3 3.3.6.2.4 SR  3.3.6.2.5
: 2. Drywell Pressure - High                    1,2,3                  2            SR 3.3.6.2.3          .:;.2.2 psig SR 3.3.6.2.4 SR 3.3.6.2.5
: 3. Reactor Building Exhaust                    1,2,3,                              SR  3.3.6.2.2        .:;.12.8 mR/hr Shaft - High Radiation                      w                                  SR SR 3.3.6.2.3 3.3.6.2.4 SR  3.3.6.2.5
: 4. Refueling Floor Exhaust                    1,2,3,                              SR  3.3.6.2.2        .:;. 10.6 mR/hr Duct - High Radiation                        w                                  SR SR 3.3.6.2.3 3.3.6.2.4 SR  3.3.6.2.5 (a) DllFIA&sect; 9Jl9Fati9RS willl a iieteRtial feF eFaiRIAg Ille Feaeter \'essel.
DAEC                                                                    3.3-65                                            Amendmentm
 
SFU System Instrumentation 3.3.7.1 3.3 INSTRUMENTATION 3.3.7.1 Standby Filter Unit (SFU) System Instrumentation LCO 3.3.7.1              Two channels of the Control Building Intake Area Radiation - High Function shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE ALTERATIONS, During Operations with a Potential for Draining the Reactor Vessel (OPDRVs).
ACTIONS
------------------------------------------------NOTE--------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                          REQUIRED ACTION                    COMPLETION TIME A.      One or both channels                A.1    Declare associated            1 hour inoperable.                                SFU subsystem(s) inoperable.
OR A.2    Place associated SFU          1 hour subsystem(s) in the isolation mode.
DAEC                                            3.3-70                                Amendment ~
 
      , RPV WATER INVENTORY CONTROL, ECCS- Operating 3.5.1 3.5 EMERGENCY CORE COOLING SYSTEMS (ECC                                    AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM 3.5.1 ECCS -        Operating LCO 3.5.1                Each ECCS injection/spray subsystem and the Automatic Depressurization System (ADS) function of four safety/relief valves .
shall be OPERABLE.
APPLICABILITY:            MODE 1, MODES 2 and 3, except High Pressure Coolant Injection (HPCI) is not required to be OPERABLE with reactor steam dome pressure ~ 150 psig and ADS valves are not required to be OPERABLE with reactor steam dome pressure~ 100 psig.
ACTIONS
--------------------------------------------------------NOTE-----------------------------------~----------------1 LCO 3.0.4.b is not applicable to HPCI.
----------------------------------------------------------------------------------~----------------------------------
CONDITION                            REQUIRED ACTION                        COMPLETION TIME A.      One Residual Heat                  A.1      Restore RHR pump to              30 Days Removal (RHR) pump                          OPERABLE status.
inoperable.
B.      One low pressure ECCS B.1                    Restore low pressure              7 days subsystem inoperable for                    ECCS subsystem to reasons other than                          OPERABLE status.
Condition A.
C.      One Core Spray                      C.1      Restore Core Spray                72 hours subsystem inoperable.                        subsystem to OPERABLE status.
AND One or two RHR                      OR pump(s) inoperable.                                                            72 hours C.2      Restore RHR pump(s) to OPERABLE status.
D.      Both Core Spray                      D.1      Restore one Core                  72 hours subsystems inoperable.                        Spray subsystem to OPERABLE status.
(continued)
DAEC                                              3.5-1                            Amendment AM8            ~
 
DRAIN TIME of RPV water inventory to the top of active fuel              jRPV Water Inventory Control (TAF) shall be ~ 36 hours.
                                                                                        ~      EGGS        Shutdown 3.5.2 One I*
RPV WATER INVENTORY CONTROL, AND
  ....___ _ _      3-.5- E
_M _E_R_G_E_N_C_Y_C_O_R_E_C_O_O_L_IN_G_S_Y__,STEMS (ECCS)\4..ND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM I
Shutdown Reactor Pressure Vessel (RPV) Water Inventory Control
                                          +we low pressure ECCS subsystems shall be OPERABLE.
APPLICABILITY:          MODE 4, l MODES 4 and 5            !
MODE 5, xcept with the spen fuel storage pool gates removed and water level ~ 21 ft 1 inch over the top of the reactor pressure vessel flange .
ACTIONS
            !Required      l  CONDITION                        REQUIRED ACTION                COMPLETION TIME
                              ~
A.      One required ECCS                A.1    Restore required          4 hours subsystem Inoperable.                  ECCS subsystem to OPERABLE status.
B.      Required Action and              B.1    lnlUate asUon to            Immediately associated Completion                  suspend Operations Time of Condition A                    With a Potential for ~ Initiate action to establish a not met.                                Draining the Reactor      , method of water injection
                                                                  )Jessel (QPDRVs~ .          capable of operating without offsite electrical power.
                  ~        gotl=I required EGGS            G4      Initiate action to          Immediately subsystems Inoperable.                  suspend OPDRVs.
ANG
                                                          ~      Restore one eCGS            4 hours INSERT C (3.5.2)        I                                        subsystem to OPERAgbe status.
(continued)
DAEC                                          3.5-8                            Amendment ~
 
INSERT C (3.5.2)
C. DRAIN TIME< 36 hours C.1  Verify secondary 4 hours and<:: 8 hours.          containment boundary is capable of being established in less than the DRAIN TIME.
AND C.2 Verify each secondary        4 hours containment penetration flow path is capable of being isolated in less than the DRAIN TIME.
AND C.3 Verify one standby gas        4 hours treatment subsystem Is capable of being placed in operation In less than the DRAIN TIME.
 
                                  ~jR_P_v_w_a_te_r_ln_v_e_nt_o_ry_c_o_n_tr_o_I_ ___.~ F-E"-C"""'C..S..-"""
                                                                                                  ;:i S~h.wu...tEIHo1o111o
                                                                                                                    -l wr++n 3.5.2 ACTIONS (continued)
CONDITION                            REQUIRED ACTION                  COMPLETION TIME RequireEI Action C.2            M          Initiate action to            lmmeEliately anEI associateEI                          restore SeconElary Completion Time not                        Containment to met,.                                      OPERABLE status.
INSERT D (3.5.2)  I
                                                      ~          Initiate action to          lmmeEliately restore one StanElby Gas Treatment subsystem to OPERABLE status.
                                                      ~          Initiate action to          lmmeEliately restore Isolation capability In each requireEI SeconElary Containment penetration flow path not isolateEI.
SURVEILLANCE REQUIREMENTS
            .....                        SURVEILLANCE                                            FREQUENCY it/a SR 3.5.2.4          Verify, for eaffi required Low Pressure                    In accordance with
                      ~
Coolant Injection (LPCI) subsystem, the                    the Surveillance suppression pool water level is~ 7.0 ft.                  Frequency Control*
Program (continued)
ISR 3.5.2.1  Verify DRAIN TIME 2! 36 hours.                                    In accordance with the Surveillance Frequency Control Program DAEC                                            3.5-9                              Amendment ~
 
INSERT D (3.5.2)
D. DRAIN TIME< 8 hours.      D.1  ----------- NOTE ---------------
Required ECCS injection/spray subsystem or additional method of water injection shall be capable of operating without offsite electrical power.
Initiate action to establish          Immediately an additional method of water injection with water sources capable of maintaining RPV water level > TAF for~ 36 hours.
AND D.2  Initiate action to establish          Immediately secondary containment boundary.
AND D.3  Initiate action to isolate            Immediately each secondary containment penetration flow path or verify It can be manually isolated from the control room.
AND D.4  Initiate action to verify one        Immediately standby gas treatment subsystem is capable of being placed in operation.
E. Required Action and      E.1  Initiate action to restore Immediately associated Completion        DRAIN TIME to ~ 36 hours.
Time of Condition C or D not met.
OR DRAIN TIME< 1 hour.
 
IRPV Water Inventory Control
                                                                            ~ EGGS        Shutdown 3.5.2 SURVEILLANCE REQUIREMENTS continued SURVEILLANCE                                          FREQUENCY
                                  ~a SR 3.5.2. ~      Verify, for ea6R required Core Spray (CS)                      In accordance subsystem, the:                                                with the
        ~        a.      Suppression pool water level is;::: 8.0 ft; or Surveillance Frequency Control Program
: b.                          f>JOTE Only one requ ired CS subsystem may take srodit Jar this option during OPDRVs.
Condensate storage tank water level in one CST Is 2 11 ft or ;::: 7 ft in both CSTs.
SR 3.5.2.3      Verify, for eaGl:l required ECCS injection/spray subsystem, locations susceptible to gas accumulation are sufficiently filled with water.
In accordance with the Surveillance r
Frequency Control Program SR 3.5.2.4          ------------------------N()TE----------------------------
t@]    GRS LPCI subsystem may be considered
()PERABLE during alignment and operation for decay heat removal if capable of being manually realigned and not otherwise inoperable.
                ---------------------------N()TE----------------------------
Not required to be met for system vent flow paths opened under administrative control.
          ~'                                                        Jeach
          "-----Verifyea6R required ECCS subsystem                              In accordance power operated and automatic valve in the                      with the flow path, that is not locked, sealed, or                      Surveillance otherwise secured in position, is in the                        Frequency correct position.                                              Control Program (continued)
DAEC                                        3.5-10                            Amendment ~
 
IRPV Water Inventory Control      r--->4- EGGS          Shutdown 3.5.2 SURVEILLANCE REQUIREMENTS (continued)
                          -~                SURVEILLANCE                                          FREQUENCY r
SR 3.5.2.&        Verify each required EGGS pump develops the specified flow rate against a system head corresponding to tho              In specified reactor pressure .                                    accordance Operate the required ECCS injection/
with the lnservice spray subsystem through the                                              SYSTEM HEAD            Testing recirculation line for 2:. 10 minutes.                          WQ.      CORRESPONDING          Program
                                                                ~        TO A REACTOR SYSTEM FLOVV RATE            PUMPS PRESSURE OF r 2718 gpm      4-      r 113 psig
                                                ?:: 4320 gpm    4-      ?:: 20 psig SR 3.5.2.6                                      NOTES 4-:-  Vessel Injection/spray may be excluded .
                                  ~      For tho LPCI System, tho survoillanoo may be met by any series of sequential and/or overlapplng steps, such that the LPCI Loop Seleot function Is tested .
Verify each required EGGS subsystem actuates on an              In accordance actual or simulated automatic initiation signal.                'Nith the Survoillanoo Frequency Control Program SR 3.5.2 .7    Verify each valve credited for automatically isolating a      In accordance penetration flow path actuates to the isolation position on an actual or      with the simulated isolation signal.                                                  Surveillance
,_____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ______.Control                    Frequency Program DAEC                                        3.5-11                            Amendment ~
 
                                                  , RPV Water Inventory                      RCIC System Control ,                                            3.5.3 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM 3.5.3 RCIC System LCO 3.5.3                The RCIC System shall be OPERABLE .
APPLICABILITY:            MODE 1, MODES 2 and 3 with reactor steam dome pressure > 150 psig.
ACTIONS
----------------------------------------------------NOTE----------------------------------------------------
LCO 3.0.4 .b is not applicable to RCIC .
CONDITION                              REQUIRED ACTION                  COMPLETION TIME A.      RCIC System                        A.1    Verify by administrative      Immediately inoperable.                                means High Pressure Coolant Injection System is OPERABLE.
AND A.2    Restore RCIC System            14 days to OPERABLE status.
B.      Required Action and                B.1    Be in MODE 3.                  12 hours associated Completion Time not met.                      AND B.2    Reduce reactor                36 hours steam dome pressure to s 150 psig.
DAEC                                              3.5-12                    Amendment AM8 ~
 
PC IVs 3.6.1.3 3.6 CONTAINMENT SYSTEMS 3.6.1.3 Primary Containment Isolation Valves (PCIVs)
LCO 3.6.1.3              Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3 MODES 4 anEI 5 for ShutElown Cooling Systsm Isolation Valves when tho associatsEI instrumsntation is roquirsEI to bs OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."
ACTIONS
-------------------------------------------------------NOTES--------------------------------------------------
: 1. Penetration flow paths may be unisolated intermittently under administrative controls.
: 2. Separate Condition entry is allowed for each penetration flow path.
: 3. Enter applicable Conditions and Required Actions for systems made inoperable by PC IVs.
: 4. Enter applicable Conditions and Required Actions of LCO 3.6.1.1, "Primary Containment," when PCIV leakage results in exceeding overall containment leakage rate acceptance criteria in MODES 1, 2, and 3.
CONDITION                            REQUIRED ACTION                COMPLETION TIME A.      -------------NOTE-----------        A.1      Isolate the affected        4 hours except for Only applicable to                          penetration flow path        main steam line penetration flow paths                      by use of at least one with two PCIVs.                              closed and de-              AND
        --------------------------------            activated automatic valve, closed manual        8 hours for main One or more                                  valve, blind flange, or    steam line penetration flow paths                      check valve with flow with one PCIV                                through the valve inoperable except for                        secured.
MSIV or purge valve leakage not within limits.          AND (continued)
DAEC                                              3.6-8                              Amendment ~
 
PC IVs 3.6.1.3 ACTIONS CONDITION                  REQUIRED ACTION                  COMPLETION TIME E.    (continued)              E.3    ----------NOTES----------
: 2. Isolation devices that are locked,                                    I sealed, or otherwise secured                                1 may be verified by use of administrative means.
Verify the affected              Once per 31 days for penetration flow path is isolation device isolated.                        outside containment 12 hours F. Required Action and      F.1    Be in MODE 3.
associated Completion    AND Time of Condition A, B,                                          36 hours C, D, or E not met ff:l  F.2    Be in MODE 4.
IVIGl;>e ~ , ~ . 9F 3.
~  ReE1UiFeEI AsUeA aAEI    G:-4  IAitiate astieA te              lmmeEllately assesiateEI Gem13letieA          sus13eAEI GPl;>RVs
    +ime ef GeAElitieA A, B,        witl=liA tl=le ResiElual G, 1;> , eF e Aet met feF        Fleat Rems1o1al (RFIR~
PGIV(s) F8E1UiFeEI te 9e        Sl=lutElewA GeeliAg GPeRABLe EluFiAg                System.
IVIGl;>e 4 SF a.
GR
                              ~I')
                              ~.-
l~ ! L!-L- ~-L!--
valve(s) ts GPeRABLe L- ---L---
                                                                      *~---' * -*-**
                                                                                    ''J status.
DAEC                              3.6-12                            Amendment No. ~
 
Secondary Containment 3.6.4.1 3.6 CONTAINMENT SYSTEMS 3.6.4.1 Secondary Containment LCO 3.6.4.1        The secondary containment shall be OPERABLE.
APPLICABILITY:      MODES 1, 2, and 3, During Operations with a Potential for Draining the Reactor Vessel {
(OPDRVs) .
ACTIONS CONDITION                REQUIRED ACTION              COMPLETION TIME A.      Secondary containment    A.1    Restore secondary        4 hours inoperable in MODE: 1,            containment to
        ~ . or a.                        OPERABLE status .
B.      Required Action and      B.1    Be in MODE 3.            12 hours associated Completion Time of Condition A not  AND met.
B.2    Be in MODE 4.            36 hours G-:    SeconElaPJ containment    G-:+              NO+E:
inoperable Eluring                LCO a.a.a is not OPDRVs.                          applicable .
Initiate action to      lmmeEliately suspena OPDR}Js.                                  I I
(continued)
DAEC                                  3.6-35                          Amendment ~
 
SCIV/Ds 3.6.4.2 3.6 CONTAINMENT SYSTEMS 3.6.4.2 Secondary Containment Isolation Valves/Dampers (SCIV/Ds)
LCO 3.6.4.2              Each SCIV/D shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3, During Operations with a Potential for Draining the Reactor Vessel ,(
(OPDRVs).
ACTIONS
--------------------------------------------------------NOTES--------------------------------------------------
: 1. -Penetration flow paths may be unisolated intermittently under administrative controls .
: 2. Separate Condition entry is allowed for each penetration flow path .
: 3. Enter applicable Conditions and Required Actions for systems made inoperable by SCIV/Ds.
CONDITION                            REQUIRED ACTION                  COMPLETION TIME A.        One or more                      A.1      Isolate the affected        8 hours penetration flow                            penetration flow path paths with one                              by use of at least one SCIV/D Inoperable.                          closed and de-activated automatic valve/damper, closed manual valve, or blind flange.
(continued)
DAEC                                            3.6-37                              Amendment ~
 
SCIV/Ds 3.6.4.2 ACTIONS (continued)
CONDITION              REQUIRED ACTION    COMPLETION TIME
~    Requ ired Action and    D.1            NOTE associated Completion        LCO a.O.a is not Time of Condition A or B    applicable.
not mot during OPDRVs.
I I
Initiate action to Immediately suspend OPDRVs.
DAEC                          3.6-39                Amendment ~
 
SBGT System 3.6.4.3 3.6 CONTAINMENT SYSTEMS 3.6.4.3 Standby Gas Treatment (SBGT) System LCO 3.6.4.3        Two SBGT subsystems shall be OPERABLE.
APPLICABILITY:      MODES 1, 2, and 3, During Operations with a Potential for Draining tho Roaster Vessel  -f (OPDRVs).
ACTIONS CONDITION                      REQUIRED ACTION              COMPLETION TIME A. One SBGT subsystem          A.1    Restore SBGT              7 days inoperable.                        subsystem to OPERABLE status.
B. Required Action and        B.1    Be In MODE 3.              12 hours associated Completion Time of Condition A not    AND met in MO(;H~ ~ , ~ . or
      ~-                          B.2    Be In MODE4.              36 hours
~      Roquiroe >A~stion ane                    ~JO+e assosiatoe Completion      LCO d.0.d is not applisablo.
      +Imo of Conaition A not mot during OPDRVs.
G:4    Plass OPeRABLe          lmmoaiately aBG+ subsystem in operation .
og (continued)
DAEC                                  3.6-41                          Amendment ~
 
SBGT System 3.6.4.3 ACTIONS CONDITION                  REQUIRED ACTION        COMPLETION TIME
~    (sontinued)                ~        Initiate astion to  Immed iately            ll suspend QPQRVs.                          I G. Two SBGT subsystems inoperable in MOQE 1 , [Q
                                ?*1      Enter LCO 3.0.3. Immediately
      ~ . OF 3.
~    +1110  gBG+ suasystems    -:-+              NO+E inopeFaale dUFing                  LCQ 3.0.3 is not QPQRVs.                            app lisaale.
Initiate astio n to Immediately            l!
suspend QPQR~Js .                        I (continued)
DAEC                                3.6-42                    Amendment ~
 
SFU System 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Standby Filter Unit (SFU) System LCO 3.7.4                Two SFU subsystems shall be OPERABLE.
-------------------------------------------------------NOTE--------------------------------------------------
The control building envelope (CBE) boundary may be opened intermittently under administrative control.
APPLICABILITY:            MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE ALTERATIONS.
During Operations with a Potential for Drain ing the Reastor Vessel (OPDRVs).
ACTIONS CONDITION                            REQUIRED ACTION                      COMPLETION TIME A      One SFU subsystem                  A.1        Restore SFU subsystem          7 days Inoperable for reasons                      to OPERABLE status.
other than Condition B.
B. One or more SFU                    B.1      Initiate actions to            Immediately subsystems                                  implement mitigating Inoperable due to                            actions.
inoperable CBE                    AND boundary in MODES 1, 2, and 3.                        B.2      Verify mitigating actions        24 hours ensure CBE occupant exposures to radiological I
hazards will not exceed limits and verify by administrative means that CBE occupants are protected from smoke and chemical hazards.
AND B.3      Restore CBE boundary            90 days to OPERABLE status.
(continued)
DAEC                                              3.7-7                        Amendment No. ~
 
SFU System 3.7.4 ACTIONS (continued)
CONDITION                    REQUIRED ACTION                    COMPLETION TIME C. Required Action and      C.1      Be in MODE 3.                    12 hours associated Completion Time of Condition A or    AND B not met in MODE 1,      C.2      Be in MODE 4.                    36 hours 2, or 3.
D. Required Action and    ------------------NOTE---------------
associated Completion  LCO 3.0.3 is not applicable.
Time of Condition A    -----------------------------------------
not met during          D.1      Place OPERABLE SFU                Immediately movement of                      subsystem in the irradiated fuel                  isolation mode.
assemblies In the        OR secondary contalnment,during      D.2.1 Suspend movement of                  Immediately CORE                              Irradiated fuel AL TERATIONS,""*                  assemblies In the during OPDRVs.                    secondary containment.
AND D.2.2 Suspend CORE                        Immediately ALTERATIONS .
ANG n ')
                              -*-*-'2  lni+i~'~ ~~" ~~ '~ "' '"~~~r1
                                            -*- - * --* -    -  -r -  -*      --  - _.,,
1~----' ' -L-1 .
OPDRVs.
E. Both SFU subsystems      E.1      Enter LCO 3.0.3                  Immediately inoperable in MODE 1, 2 or 3 for reasons other than Condition B.
(continued)
DAEC                              3.7-8                              Amendment No. ~
 
SFU System 3.7.4 ACTIONS (continued)
CONDITION                      REQUIRED ACTION                      COMPLETION TIME F. Both SFU subsystems      ----------------1\!0TE----------------
inoperable during        LCO 3.0.3 is not applicable.
movement of irradiated  -----------------------------------------
fuel assembles in the secondary                F.1 Suspend movement of                    Immediately containment, during            irradiated fuel assemblies CORE ALTERATIONS,                in the secondary or during OPDRVs.              containment.
OR                        AND One or more SFU          F.2 Suspend CORE                          Immediately subsystems inoperable          ALTERATIONS.
due to an inoperable CBE boundary during      ANG movement of Irradiated fuel assemblies In the    F.a  Initiate aotion to suspend          Immediately secondary                      OPDRVs.
containment, during CORE ALTERATIONS, or during OPDR\ls.
SURVEILLANCE REQUIREMENTS SR 3.7.4.1
                  ~
SURVEILLANCE Operate each SFU subsystem for 15 minutes.
FREQUENCY In accordance with the Surveillance Frequency Control Program 1
SR 3.7.4.2        Perform required SFU filter testing In                  In accordance with the accordance with the Ventilation Filter Testing          VFTP Program (VFTP).
(continued)
DAEC                                  3.7-9                                Amendment ~
 
CBC System 3.7.5 3.7 PLANT SYSTEMS 3.7.5 Control Building Chiller (CBC) System LCO 3.7.5          Two CBC subsystems shall be OPERABLE.
APPLICABILITY:      MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE ALTERATIONS, During Opsrations 111ith a Potential f-Or Draining the Reactor Vessel (OPDR'ls).
ACTIONS CONDITION                    REQUIRED ACTION                COMPLETION TIME A. One CBC subsystem          A.1    Restore CBC                30 days Inoperable.                        subsystem to OPERABLE status.
B. Two CBC subsystems          B.1    Verify control building    Once per 4 hours inoperable.                          area temperatures
                                          < 90&deg;F.
AND B.2    Restore one CBC            72 hours subsystem to OPERABLE status.
C. Required Action and          C.1    Be in MODE 3.              12 hours associated Completion Time of Condition A or B    AND not met In MODE 1, 2, or 3.                        C.2    Be in MODE 4.              36 hours (continued)
DAEC                                  3.7-11                          Amendment ~        (
 
CBC System 3.7.5 ACTIONS (continued)
CONDITION                REQUIRED ACTION                    COMPLETION TIME D. Required Action and  ------------------NOTE---------------                        1 associated Completion LCO 3.0.3 is not applicable.
Time of Condition A  -----------------------------------------
not met during        D.1      Place OPERABLE CBC              Immediately movement of                    subsystem in operation.
Irradiated fuel assemblies in the      OR secondary containment, during    D.2.1 Suspend movement of                Immediately CORE                            irradiated fuel AL TERATIONS,-9f                assemblies in the duriRg QPgRvs.                  secondary containment.
AND D.2.2 Suspend CORE                        Immediately ALTERATIONS.
AfID g.~.a    IRiUate astieR te                Immediately sus13eRd QPgRvs.
(continued)
DAEC                          3.7-12                                  Amendment ~
 
CBC System 3.7.5 ACTIONS (continued)
CONDITION                        REQUIRED ACTION                  COMPLETION TIME E. Required Action and            ------------------NOTE---------------
associated Completion          LCO 3.0.3 is not applicable.
Time of Condition B not met during movement            E.1      Suspend movement              Immediately of irradiated fuel                      of irradiated fuel assemblies in the                      assemblies in the secondary containment,                  secondary during CORE                            containment.
AL TERATIONS,-ei:
during OPDRVs.                AND E.2      Suspend CORE                  Immediately ALTERATIONS.
                                    -:-3    Initiate astlon to            Immediately suspend OPDRVs.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                        FREQUENCY SR 3.7.5.1          Verify each CBC subsystem has the                    In accordance with the capability to remove the available heat load.        Surveillance Frequency Control Program DAEC                                      3.7-13                          Amendment ~
 
AC Sources - Shutdown 3.8.2 ACTIONS
---------------------------------------------------N()TE:----------------------------------------------------------
LC() 3.0.3 is not applicable.
C()NDITl()N                            RE:QUIRE:D ACTl()N                  COMPLE:Tl()N TIME:
A.        ()ne required offsite              ----------------NOTE:------------------
circuit inoperable.                E:nter applicable Condition and Required Actions of LC() 3.8.8, with one required division de-energized as a result of Condition A.
A.1        Declare affected                Immediately required feature(s),
with no offsite power available, Inoperable.
()R A.2.1      Suspend C()RE:                  Immediately ALTE:RATl()NS.
AND A.2.2      Suspend movement                Immediately of Irradiated fuel assemblies in the secondary containment.
ANQ.
                                            ~          Initiate action to              Immediately suspend Operations with a Potential for Draining the Reactor Vessel (OPDRVs).
AND A.2.4      Initiate action to restore      Immediately
                                                  'i'    required offsite power
                                                  @] circuit to OPE:RABLE:
status.
(continued)
DAE:C                                            3.8-12                                    Amendment ~
 
AC Sources - Shutdown 3.8.2 ACTIONS (continued)
CONDITION                          REQUIRED ACTION                COMPLETION TIME B.      One required DG              B.1        Suspend CORE                Immediately inoperable.                            ALTERATIONS.
AND B.2      Suspend movement            Immediately of irradiated fuel assemblies in secondary containment ANG
                                      ~        IRitiats astieR te          lmmsdiatsly suspsRd Ofi>DRVs.
AND B.4        Initiate action to restore Immediately required DG to
                                      ~        OPERABLE status.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                          FREQUENCY SR 3.8.2.1      -------------------------NOTES----------------------------
: 1. The following SRs are not required to be performed: SR 3.8.1 .3, SR 3.8.1 .9 through SR 3.8.1.13.
: 2. SR 3.8.1.13 is considered to be met without the ECCS initiation signals OPERABLE when the ECCS initiation signals are not required to be OPERABLE per Table 3.3.5.1-1.
For AC sources required to be OPERABLE, the                In accordance SRs of Specification 3.8.1, except SR 3.8.1.8,              with applicable are applicable.                                            SRs DAEC                                      3.8-13                          Amendment No.    ~
 
DC Sources -    Shutdown 3.8.5 ACTIONS CONDITION                        REQUIRED ACTION                  COMPLETION TIME A.      (continued)                  ~          Initiate action to          Immediately suspend operations with a potential for draining tho reactor vessel .
A.2.4    Initiate action to          Immediately
                                        ~
restore required DC electrical power subsystems to OPERABLE status.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                          FREQUENCY SR 3.8.5.1      -------------------------NOTE-----------------------------
The following SRs are not required to be performed : SR 3.8.4.7 and SR 3.8.4.8.
For DC electrical power subsystems required                In accordance to be OPERABLE the following SRs are                        with applicable applicable:                                                SRs SR 3.8.4.1        SR 3.8.4.4      SR 3.8.4.7 SR 3.8.4.2        SR 3.8.4.5      SR 3.8.4.8.
SR 3.8.4 .3      SR 3.8.4.6 DAEC                                      3.8-22                                Amendment ~
 
Distribution Systems -      Shutdown 3.8.8 3.8 ELECTRICAL POWER SYSTEMS 3.8.8 Distribution Systems -            Shutdown LCO 3.8.8                The necessary portions of the AC and DC electrical power distribution subsystems shall be OPERABLE to support equipment required to be OPERABLE.
APPLICABILITY:            MODES 4 and 5.
During movement of irradiated fuel assemblies in the secondary containment.
ACTIONS
-----------------------------------------------------------NOTE-------------------------------------------------------
LCO 3.0.3 is not applicable.
CONDITION                              REQUIRED ACTION                      COMPLETION TIME A.        One or more required              A.1          Declare associated          Immediately AC or DC electrical                            supported required power distribution                              feature(s) Inoperable.
subsytems Inoperable.
OR Immediately A.2.1        Suspend CORE ALTERATIONS.
AND A.2.2        Suspend movement            Immediately of irradiated fuel assemblies in the secondary containment.
ANQ.
                                            ~            Initiate action to          Immediately sblspend operations with a potential for draining tho reactor vessel .
(continued)
DAEC                                            3.8-30                              Amendment ~
 
Distribution Systems -  Shutdown 3.8.8 ACTIONS (continued)
CONDITION                    REQUIRED ACTION                  COMPLETION TIME A.      (continued)            A.2 .4    Initiate actions to        Immediately restore required AC 3
and DC electfrcal power distribution subsytems to OPERABLE status.
AND A.2.a      Declare associated          Immediately t
required shutdown cooling subsystem(s) inoperable.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                      FREQUENCY SR 3.8 .8.1        Verify correct breaker alignments and              In accordance with the indicated power availability to required AC        Surveillance and DC electrical power distribution              Frequency Control subsystems.                                        Program DAEC                                3.8-31                            Amendment ~
 
ATTACHMENT 3 TO NG-17-0093 Revised Technical Specifications Pages 81 Pages Follow
 
Definitions 1.1 1.1 Definitions (continued)
CORE OPERATING LIMITS      The COLR is the unit specific document that provides REPORT (COLR)              cycle specific parameter limits for the current reload cycle.
These cycle specific limits shall be determined for each reload cycle in accordance with Specification 5.6.5. Plant operation within these limits is addressed in individual Specifications.
DOSE EQUIVALENT 1-131 shall be that concentration of DOSE EQUIVALENT 1-131 1-131 (microcuries/ml), that alone would produce the same dose as the quantity and isotopic mixture of 1-131, 1-132, 1-133, 1-134, and 1-135 actually present.
The dose conversion factors used for this calculation shall be those listed in Federal Guidance Report (FGR) 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion," 1989 and FGR 12, "External Exposure to Radionuclides in Air, Water, and Soil," 1993.
DRAIN TIME                The DRAIN TIME is the time it would take for the water inventory in and above the Reactor Pressure Vessel (RPV) to drain to the top of the active fuel (TAF) seated in the RPV assuming:
a) The water inventory above the TAF is divided by the limiting drain rate; (cont'd)
(continued)
DAEC                              1.1-3                                Amendment
 
Definitions 1.1 1.1 Definitions (continued)
DRAIN TIME (cont'd)        b) The limiting drain rate is the larger of the drain rate through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g., seismic event, loss of normal power, single human error), for all penetration flow paths below the TAF except:
: 1. Penetration flow paths connected to an intact closed system, or isolated by manual or automatic valves that are locked, sealed, or otherwise secured in the closed position, blank flanges, or other devices that prevent flow of reactor coolant through the penetration flow paths;
: 2. Penetration flow paths capable of being isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation; or
: 3. Penetration flow paths with isolation devices that can be closed prior to the RPV water level being equal to the TAF by a dedicated operator trained in the task, who is in continuous communication with the control room, is stationed at the controls, and is capable of closing the penetration flow path isolation device without offsite power.
c) The penetration flow paths required to be evaluated per paragraph b) are assumed to open instantaneously and are not subsequently isolated, and no water is assumed to be subsequently added to the RPV water inventory; d) No additional draining events occur; and e) Realistic cross-sectional areas and drain rates are used.
A bounding DRAIN TIME may be used in lieu of a calculated value.
(continued)
DAEC                          1.1-4                                  Amendment
 
Definitions 1.1 1.1 Definitions (continued)
END OF CYCLE              The EOG RPT SYSTEM RESPONSE TIME shall be that RECIRCULATION PUMP        time interval from initial signal generation by the TRIP (EOG RPT) SYSTEM      associated turbine stop valve limit switch or from when RESPONSE TIME              the turbine control valve hydraulic oil control oil pressure drops below the pressure switch setpoint to actuation of the breaker secondary (auxiliary) contact. The response time may be measured by means of any series of sequential, overlapping, or total steps so that the entire response time is measured.
(continued)
DAEC                              1.1-5                                  Amendment
 
Definitions 1.1 1.1 Definitions (continued)
LEAKAGE                    LEAKAGE shall be:
: a. Identified LEAKAGE
: 1. LEAKAGE into the drywell, such as that from pump seals or valve packing, that is captured and conducted to a sump or collecting tank; or
: 2. LEAKAGE into the drywell atmosphere from sources that are both specifically located and known not to interfere with the operation of leakage detection systems;
: b. Unidentified LEAKAGE All LEAKAGE into the drywell that is not identified LEAKAGE;
: c. Total LEAKAGE Sum of the identified and unidentified LEAKAGE.
LOGIC SYSTEM              A LOGIC SYSTEM FUNCTIONAL TEST shall be a test FUNCTIONAL TEST            of all logic components required for OPERABILITY of a logic circuit, from as close to the sensor as practicable up to, but not including, the actuated device, to verify OPERABILITY. The LOGIC SYSTEM FUNCTIONAL TEST may be performed by means of any series of sequential, overlapping, or total system steps so that the entire logic system is tested.
MINIMUM CRITICAL            The MCPR shall be the smallest critical power POWER RATIO (MCPR)          ratio (CPR) that exists in the core for each class of fuel.
The CPR is that power in the assembly that is calculated by application of the appropriate correlation(s) to cause some point in the assembly to experience transition boiling, divided by the actual assembly operating power.
Transition boiling means the boiling regime between nucleate and film boiling. Transition boiling is the regime in which both nucleate and (continued)
DAEC                                1.1-6                          Amendment 234 Repaginated per Amendment_
 
Definitions 1.1 1.1  Definitions (continued)
MINIMUM CRITICAL            film boiling occur intermittently with neither type being POWER RATIO (MCPR)          completely stable.
MODE                        A MODE shall correspond to any one inclusive combination of mode switch position, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Table 1.1-1 with fuel in the reactor vessel.
OPERABLE- OPERABILITY A system, subsystem, division, component, or device shall be OPERABLE or have OPERABILITY when it is capable of performing its specified safety function(s) and when all necessary attendant instrumentation, controls, normal or emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, division, component, or device to perform its specified safety function(s) are also capable of performing their related support function(s).
PRESSURE AND                  The PTLR is the unit specific document that provides TEMPERATURE LIMITS            the reactor vessel pressure and temperature limits, REPORT (PTLR)                including heatup and cooldown rates, for the current reactor vessel fluence period. These pressure and temperature limits shall be determined for each fluence period in accordance with Specification 5.6. 7.
RATED THERMAL                RTP shall be a total reactor core heat transfer rate to POWER (RTP)                  the reactor coolant of 1912 MWt.
REACTOR                      The RPS RESPONSE TIME shall be that time interval PROTECTION SYSTEM            from when the monitored parameter exceeds its RPS (RPS) RESPONSE              trip setpoint at the channel sensor until de-TIME                        energization of the scram pilot valve solenoids. The response time may be measured by means of any series of sequential, overlapping, or total steps so that the entire response time is measured.
(continued)
DAEC                                1.1-7                            Amendment 294 Repaginated per Amendment_
 
Definitions 1.1 1.1 Definitions (continued)
SHUTDOWN MARGIN            SOM shall be the amount of reactivity by which the (SOM)                      reactor is subcritical or would be subcritical throughout the operating cycle assuming that:
: a. The reactor is xenon free;
: b. The moderator temperature is ~ 68&deg;F (20&deg;C),
corresponding to the most reactive state; and
: c. All control rods are fully inserted except for the single control rod of highest reactivity worth, which is assumed to be fully withdrawn with the core in its most reactive state during the operating cycle. With control rods not capable of being fully inserted, the reactivity worth of these control rods must be accounted for in the determination of SOM.
(continued)
OAEC                              1.1-8                          Amendment 288 Repaginated per Amendment_
 
Definitions 1.1 1.1  Definitions (continued)
THERMAL POWER                THERMAL POWER shall be the total reactor core heat transfer rate to the reactor coolant.
TURBINE BYPASS SYSTEM        The TURBINE BYPASS SYSTEM RESPONSE TIME                RESPONSE TIME consists of two components:
: a. The time from initial movement of the main turbine stop valve or control valve until 80% of the turbine bypass capacity is established; and
: b. The time from initial movement of the main turbine stop valve or control valve until initial movement of the turbine bypass valve.
The response time may be measured by means of any series of sequential, overlapping, or total steps so that the entire response time is measured.
(continued)
DAEC                              1.1-9                            Amendment 223 Repaginated per Amendment_
 
Definitions 1.1 Table 1.1-1 (page 1 of 1)
MODES REACTOR MODE                    AVERAGE SWITCH                    REACTOR MODE            TITLE POSITION                    COOLANT TEMPERATURE (&deg;F) 1        Power Operation          Run                                NA 2        Startup                  Refuel(a) or Startup/Hot          NA Standby 3        Hot Shutdown(a)          Shutdown                          > 212 4        Cold Shutdown(a)          Shutdown                          :::;; 212 5        Refueling(b)              Shutdown or Refuel                NA (a)  All reactor vessel head closure bolts fully tensioned.
(b)  One or more reactor vessel head closure bolts less than fully tensioned.
DAEC                                  1.1-10                          Amendment 223 Repaginated per Amendment_
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION                    COMPLETION TIME B. As required by      B.1  --------------NOTE-----------
Required Action A.1        Only applicable for and referenced in          Functions 1.a, 1.b, 2.a, Table 3.3.5.1-1            and 2.b.
Declare supported              1 hour from discovery of feature(s) inoperable          loss of initiation when redundant                capability for feature(s) feature(s) ECCS                in two or more low initiation capability is      pressure ECCS inoperable.                    subsystems AND B.2    --------------NOTE------------
Only applicable for Functions 3.a and 3.b.
Declare High Pressure          1 hour from discovery of Coolant Injection (HPCI)      loss of HPCI initiation System inoperable.            capability AND B.3    Place channel in trip.        24 hours (continued)
DAEC                            3.3-33                                Amendment
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION              REQUIRED ACTION                      COMPLETION TIME C. As required by      C.1 ------------NOTE----------
Required Action A.1      Only applicable for and referenced in        Functions 1.c, 1.e, 2.c Table 3.3.5.1-1.        and 2.e.
Declare supported                1 hour from feature(s) inoperable.            discovery of loss of initiation capability for two or more low pressure ECCS subsystems AND C.2  -------------NOTE--------
Only applicable for Functions 2.g, 2.h, 2.i, and 2.j.
Declare Low Pressure              1 hour from Coolant Injection                discovery of loss of (LPCI) subsystem                  Loop Selection inoperable.                      capability AND C.3  Restore channel to                24 hours OPERABLE status.
(continued)
DAEC                          3.3-34                                      Amendment
 
ECCS Instrumentation 3.3.5.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION                      COMPLETION TIME E. As required by      E.1  ----------N 0 TE----------
Required Action A.1      Only applicable for and referenced in        Functions 1.d and 2.f.
Table 3.3.5.1-1.          -------------------------------
Declare supported                1 hour from discovery of feature(s) inoperable.          loss of initiation capability for two or more minimum flow valves in the low pressure ECCS subsystems AND E.2  Restore channel to              7 days OPERABLE status.
F. As required by      F.1  Restore channel to                1 hour Required Action A.1      OPERABLE status.
and referenced in Table 3.3.5.1-1.
(continued)
DAEC                            3.3-36                                  Amendment
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 1 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                          CONDITIONS MODES        REQUIRED          REFERENCED OR OTHER        CHANNELS              FROM SPECIFIED          PER            REQUIRED          SURVEILLANCE                ALLOWABLE CONDITIONS        FUNCTION          ACTION A.1        REQUIREMENTS                VALUE FUNCTION
: 1. Core Spray System
: a. Reactor Vessel Water              1,2,3,            4(a)                B            SR  3.3.5.1.1    ?. 38.3 inches Level - Low Low Low                                                                SR  3.3.5.1.3 SR  3.3.5.1.8 SR  3.3.5.1.9
: b. Drywell Pressure -                1,2,3            4(a)                B            SR 3.3.5.1.3    _:::2.19 psig High                                                                              SR 3.3.5.1.8 SR 3.3.5.1.9
: c. Reactor Steam Dome                1,2,3            4                  c            SR 3.3.5.1.3    ?. 363.3 psig Pressure - Low                                                                    SR 3.3.5.1.8    and_::: 485.1 psig (Injection Permissive)                                                            SR 3.3.5.1.9
: d. Core Spray Pump                  1,2,3          1 per                E            SR 3.3.5.1.3    ?. 256.6 gpm Discharge Flow - Low                          pump                                SR 3.3.5.1.8      and (Bypass)                                                                          SR 3.3.5.1.9    _:::2382.1 gpm
: e. Core Spray Pump Start            1,2,3          1 per                c            SR 3.3.5.1.8      ?. 2.6 seconds Time Delay Relay                              pump                              SR 3.3.5.1.9      and _::: 6.8 seconds
: f. 4.16 kV Emergency Bus            1,2,3          1 per                  F          SR 3.3.5.1.5      ::: 3500 v Sequential Loading                            pump                              SR 3.3.5.1.6 Relay                                                                            SR 3.3.5.1.9
: 2. Low Pressure Coolant Injection (LPCI) System
: a. Reactor Vessel Water            1,2,3            4                  B            SR  3.3.5.1.1    ?. 38.3 inches Level- Low Low Low                                                                SR  3.3.5.1.3 SR  3.3.5.1.8 SR  3.3.5.1.9
: b. Drywell Pressure -              1,2,3            4                  B            SR 3.3.5.1.3      _::: 2.19 psig High                                                                              SR 3.3.5.1.8 SR 3.3.5.1.9 continued (a) Also required to initiate the associated Diesel Generator (DG).
DAEC                                                              3.3-41                                                    Amendment
 
EGGS Instrumentation 3.3.5.1 Table 3.3.5.1-1(page2 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                      CONDITIONS MODES          REQUIRED        REFERENCED OR OTHER        CHANNELS              FROM REQUIRED    SURVEILLANCE          ALLOWABLE SPECIFIED          PER FUNCTION                                          ACTION A.1    REQUIREMENTS          VALUE CONDITIONS        FUNCTION
: 2. LPCI System (continued)
: c. Reactor Steam Dome          1,2,3              4                c      SR 3.3.5.1.3  ."'. 363.3 psig and Pressure - Low                                                        SR 3.3.5.1.8  _::: 485.1 psig (Injection Permissive)                                                SR 3.3.5.1.9
: d. Reactor Vessel Shroud      1,2,3              4                B      SR  3.3.5.1.1 ."'. -40.89 inches Level - Low                                                            SR  3.3.5.1.2 SR  3.3.5.1.4 SR  3.3.5.1.9
: e. Low Pressure Coolant        1,2,3            1 per              c      SR 3.3.5.1.8 Injection Pump                              pump                      SR 3.3.5.1.9 Start - Time Delay Relay
                                                                                            ."'. 8.8 seconds Pumps A & B                                                                          and
_::: 11.2 seconds
                                                                                            ."'. 13.8 seconds and Pumps C & D                                                                          _::: 33.5 seconds
: f. Low Pressure                1,2,3            1 per              E      SR 3.3.5.1.3  ."'. 471.8 gpm Coolant Injection Pump                      loop                      SR 3.3.5.1.8    and Discharge Flow - Low                                                  SR 3.3.5.1.9    _:::3676.6 gpm (Bypass)
: g. LPCI Loop Select-          1,2,3              4                c      SR  3.3.5.1.1  ."'. 112.65 inches Reactor Vessel Water                                                  SR  3.3.5.1.2 Level - Low-Low                                                      SR  3.3.5.1.6 SR  3.3.5.1.9
: h. LPCI Loop Select -          1,2,3              4                c      SR 3.3.5.1.2  ."'. 887 psig Reactor Steam Dome                                                    SR 3.3.5.1.4 Pressure - Low                                                        SR 3.3.5.1.9 (continued)
DAEC                                        3.3-42                                                      Amendment
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 3 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                              CONDITIONS MODES OR            REQUIRED          REFERENCED OTHER            CHANNELS                FROM SURVEILLANCE          ALLOWABLE SPECIFIED                PER            REQUIRED ACTION A.1 REQUIREMENTS          VALUE FUNCTION                      CONDITIONS            FUNCTION
: 2. LPCI System (continued)
LPCI Loop Select -                        1,2,3              4 per                c  SR  3.3.5.1.1  ::: 7.8 psid Recirculation Pump                                            pump                      SR  3.3.5.1.2 Differential Pressure                                                                    SR  3.3.5.1.8 SR  3.3.5.1.9
: j. LPCI Loop Select -                          1,2,3                  4                  c  SR  3.3.5.1.1  .o:0.13psid SR  3.3.5.1.2  and ::: 2. 07 psid Recirculation Riser Differential Pressure                                                                  SR  3.3.5.1.4 SR  3.3.5.1.9
: k. 4.16 kV Emergency Bus                      1,2,3                2                  F  SR 3.3.5.1.5    S 3500V Sequential Loading                                                                      SR 3.3.5.1.6 Relay                                                                                  SR 3.3.5.1.9
: 3. High Pressure Coolant Injection (HPCI) System 1,                  4                  B  SR  3.3.5.1.1  .'.: 112.65 inches
: a. Reactor Vessel Water Level - Low Low                                                                        SR  3.3.5.1.3 2(b)' 3(b)
SR  3.3.5.1.6 SR  3.3.5.1.9 1,                  4                  B  SR 3.3.5.1.3    ::;2.19 psig
: b. Drywell Pressure -
High                                                                                  SR 3.3.5.1.8 2(b)' 3(b)
SR 3.3.5.1.9
: c. Reactor Vessel Water                        1,                  2                c  SR  3.3.5.1.1  ::: 214.8 inches Level - High                                                                            SR  3.3.5.1.3 2(b)' 3(b)
SR  3.3.5.1.6 SR  3.3.5.1.9 1,                  2                  D  SR 3.3.5.1.3    .'.: 11.6 inches
: d. Condensate Storage Tank Level - Low                                                                        SR 3.3.5.1.8 2(b)' 3(b)
SR 3.3.5.1.9 (continued)
(b) With reactor steam dome pressure> 150 psig.
DAEC                                                          3.3-43                                                      Amendment
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1(page4 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                          CONDITIONS MODES OR            REQUIRED        REFERENCED OTHER          CHANNELS              FROM REQUIRED  SURVEILLANCE          ALLOWABLE SPECIFIED              PER FUNCTION                                                              ACTIONA.1  REQUIREMENTS            VALUE CONDITIONS            FUNCTION
: 3. HPCI System (continued)
: e. Suppression Pool                              1,                2                D  SR 3.3.5.1.3  .::: 5.9 inches Water Level - High                                                                    SR 3.3.5.1.8 2(b)' 3(b)                                  SR 3.3.5.1.9
: f. High Pressure Coolant                          1, Injection Pump                          2(b)' 3(b)                              E  SR 3.3.5.1.3  ;::_264.2 gpm Discharge Flow - Low                                                                  SR 3.3.5.1.8  and (Bypass)                                                                              SR 3.3.5.1.9  .::: 2025.1 gpm
: 4. Automatic Depressurization System (ADS) Trip Logic A
: a. Reactor Vessel Water                                            2                G  SR  3.3.5.1.1  ;::. 38.3 inches Level - Low Low Low                                                                  SR  3.3.5.1.3 SR  3.3.5.1.8 SR  3.3.5.1.9
: b. Automatic                                                                          H  SR 3.3.5.1.3    _::: 125 seconds Depressurization                                                                    SR 3.3.5.1.8 System Timer                                                                        SR 3.3.5.1.9
: c. Reactor Vessel Water                                                              G  SR  3.3.5.1.1  ;::. 166.1 inches Level-Low                                                                            SR  3.3.5.1.3 (Confirmatory)                                                                      SR  3.3.5.1.8 SR  3.3.5.1.9
: d. Core Spray Pump                                                  2                H  SR 3.3.5.1.3    ;::. 114.2 psig Discharge                                                                            SR 3.3.5.1.8    and Pressure - High                                                                      SR 3.3.5.1.9    .::: 177.0 psig
: e. Low Pressure Coolant                                              4                H  SR 3.3.5.1.3    ;::. 103.8 psig Injection Pump                                                                        SR 3.3.5.1.8    and Discharge Pressure -                                                                  SR 3.3.5.1.9    .::: 147.0 psig High (continued)
(b) With reactor steam dome pressure> 150 psig.
(c) With reactor steam dome pressure > 100 psig.
DAEC                                                          3.3-44                                                  Amendment
 
ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1(page5 of 5)
Emergency Core Cooling System Instrumentation APPLICABLE                        CONDITIONS MODES OR        REQUIRED        REFERENCED OTHER        CHANNELS            FROM SPECIFIED          PER          REQUIRED      SURVEILLANCE      ALLOWABLE FUNCTION                        CONDITIONS        FUNCTION        ACTIONA.1    REQUIREMENTS        VALUE
: 5. ADS Trip Logic B
: a. Reactor Vessel Water                                          2                G        SR 3.3.5.1.1 ;:: 38.3 inches Level - Low Low Low                                                                    SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9
: b. Automatic                                                                      H        SR 3.3.5.1.3 ::= 125 seconds Depressurization                                                                        SR 3.3.5.1.8 System Timer                                                                            SR 3.3.5.1.9
: c. Reactor Vessel Water                                                          G        SR 3.3.5.1.1 ;:: 166.1 inches Level-Low                                                                              SR 3.3.5.1.3 (Confirmatory)                                                                          SR 3.3.5.1.8 SR 3.3.5.1.9
: d. Core Spray Pump                                              2                H        SR 3.3.5.1.3 ;:: 114.2 psig Discharge                                                                              SR 3.3.5.1.8  and Pressure - High                                                                        SR 3.3.5.1.9 ::= 177.0 psig
: e. Low Pressure Coolant                                          4                H        SR 3.3.5.1.3 ;:: 103.8 psig Injection Pump                                                                          SR 3.3.5.1.8  and Discharge                                                                              SR 3.3.5.1.9 ::= 147.0 psig Pressure - High (c) With reactor steam dome pressure> 100 psig.
DAEC                                                      3.3-45                                                    Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 3.3 INSTRUMENTATION 3.3.5.2 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation LCO 3.3.5.2              The RPV Water Inventory Control instrumentation for each Function in Table 3.3.5.2-1 shall be OPERABLE.
APPLICABILITY:            According to Table 3.3.5.2-1 ACTIONS
-------------------------------------------------NOTE------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                          REQUIRED ACTION                  COMPLETION TIME A.      One or more channels                A.1    Enter the Condition          Immediately inoperable.                                referenced in Table 3.3.5.2-1 for the channel.
B.      As required by                      B.1    Declare associated          Immediately Required Action A.1                        penetration flow and referenced in                          path(s) incapable of Table 3.3.5.2-1.                            automatic isolation.
AND B.2    Calculate DRAIN              Immediately TIME.
C.      As required by Required              C. 1    Place Channel in            1 hour Action A. 1 and                              trip.
referenced in Table 3.3.5.2-1.
(continued)
DAEC                                            3.3-46                                    Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 ACTIONS (continued)
CONDITION              REQUIRED ACTION            COMPLETION TIME D. As required by Required D.1  Restore channel to    24 hours Action A. 1 and              OPERABLE status.
referenced in Table 3.3.5.2-1.
E. Required Action and    E.1  Declare associated    Immediately associated Completion        ECCS Time of Condition C or        injections/spray D not met.                    subsystem inoperable.
DAEC                            3.3-47                            Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 SURVEILLANCE REQUIREMENTS
-------------------------------------------------------N()TES--------------------------------------------------
Refer to Table 3.3.5.2-1 to determine which SRs apply for each ECCS Function.
SURVEILLANCE                                                FREQUENCY SR 3.3.5.2.1                Perform CHANNEL CHECK.                                      In accordance with the Surveillance Frequency Control Program SR 3.3.5.2.2                Perform CHANNEL FUNCTl()NAL TEST.                            In accordance with the Surveillance Frequency Control Program DAEC                                              3.3-48                                        Amendment
 
RPV Water Inventory Control Instrumentation 3.3.5.2 Table 3.3.5.2-1 (page 1 of 1)
RPV Water Inventory Control Instrumentation APPLICABLE                          CONDITIONS MODES          REQUIRED          REFERENCED OR OTHER        CHANNELS              FROM SPECIFIED            PER            REQUIRED              SURVEILLANCE                  ALLOWABLE FUNCTION                CONDITIONS        FUNCTION            ACTION A.1            REQUIREMENTS                    VALUE
: 1. Core Spray System
: a. Reactor Steam Dome                4,5                4                c                SR 3.3.5.2.2          ::: 485.1 psig Pressure - Low (Injection Permissive)
: b. Core Spray Pump                  4, 5            1 per                D              SR 3.3.5.2.2          ~256.6    gpm Discharge Flow - Low                          Pump1*>                                                      and (Bypass)                                                                                                    ::: 2382.1 gpm
: 2. Low Pressure Coolant Injection (LPCI) System
: a. Reactor Steam Dome                4,5                4                c                SR 3.3.5.2.2          ::: 485.1 psig Pressure - Low (Injection Permissive)
: b. Low Pressure                      4, 5            1 per                D              SR 3.3.5.2.2          ~ 471.8 gpm and Coolant Injection Pump                            loop                                                      ::: 3676.6 gpm Discharge Flow -
Low (Bypass)
: 3. RHR System Isolation
: a. Reactor Vessel Water              (b)        2 in one trip            B              SR 3.3.5.2.1          ~    165.6 inches Level-Low                                        system                                SR 3.3.5.2.2
: 4. Reactor Water Cleanup (RWCU) System Isolation
: a. Reactor Vessel Water              (b)        2 in one trip            B              SR 3.3.5.2.1          ~  112.65 inches Level - Low Low                                  system                                SR 3.3.5.2.2 (a)    Associated with an ECCS subsystem required to be OPERABLE by LCO 3.5.2, "Reactor Pressure Vessel Water Inventory Control."
(b)    When automatic isolation of the associated penetration flow path(s) is credited in calculating DRAIN TIME.
DAEC                                                              3.3-49                                                              Amendment
 
RCIC System Instrumentation 3.3.5.3 3.3 INSTRUMENTATION 3.3.5.3 Reactor Core Isolation Cooling (RCIC) System Instrumentation LCO 3.3.5.3              The RCIC System instrumentation for each Function in Table 3.3.5.3-1 shall be OPERABLE.
APPLICABILITY:            MODE 1, MODES 2 and 3 with reactor steam dome pressure > 150 psig.
ACTIONS
-------------------------------------------------NOTE------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                          REQUIRED ACTION                  COMPLETION TIME A.      One or more channels                A.1  Enter the Condition            Immediately inoperable.                              referenced in Table 3.3.5.3-1 for the channel.
B.      As required by                      B.1    Declare RCIC                  1 hour from discovery Required Action A.1                        System inoperable.            of loss of RCIC and referenced in                                                        initiation capability Table 3.3.5.3-1.
AND 24 hours B.2    Place channel in trip.
(continued)
DAEC                                            3.3-50                                    Amendment
 
RCIC System Instrumentation 3.3.5.3 ACTIONS (continued)
CONDITION              REQUIRED ACTION                    COMPLETION TIME C. As required by        C.1    Restore channel to          24 hours Required Action A.1          OPERABLE status.
and referenced in Table 3.3.5.3-1.
D. As required by Required D.1    -----------N 0 TE---------
Action A.1 and                Only applicable if referenced in Table            RCIC pump suction is 3.3.5.3-1.                    not aligned to the suppression pool.
Declare RCIC                  1 hour from discovery of System inoperable.            loss of RCIC suction transfer capability AND D.2.1  Place channel in trip.        24 hours OR D.2.2 Align RCIC pump                24 hours suction to the suppression pool.
E. Required Action and    E.1    Declare RCIC                Immediately associated Completion          System inoperable.
Time of Condition B, C, or D not met.
DAEC                              3.3-51                                  Amendment
 
RCIC System Instrumentation 3.3.5.3 SURVEILLANCE REQUIREMENTS
-------------------------------------------------------N{)TES--------------------------------------------------
: 1. Refer to Table 3.3.5.3-1 to determine which SRs apply for each RCIC Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours for Functions 2 and 3; and (b) for up to 6 hours for Function 1 provided the associated Function maintains RCIC initiation capability.
SURVEILLANCE                                          FREQUENCY SR 3.3.5.3.1                Perform CHANNEL CHECK.                                  In accordance with the Surveillance Frequency Control Program SR 3.3.5.3.2                Perform CHANNEL FUNCTl()NAL TEST.                      In accordance with the Surveillance Frequency Control Program SR 3.3.5.3.3                Perform CHANNEL CALIBRATl()N.                          In accordance with the Surveillance Frequency Control Program SR 3.3.5.3.4                Perform CHANNEL CALIBRATl()N.                          In accordance with the Surveillance Frequency Control Program SR 3.3.5.3.5                Perform L()GIC SYSTEM FUNCTl()NAL                      In accordance with TEST.                                                    the Surveillance Frequency Control Program DAEC                                              3.3-52                                    Amendment
 
RCIC System Instrumentation 3.3.5.3 Table 3.3.5.3-1 (page 1 of 1)
Reactor Core Isolation Cooling System Instrumentation CONDITIONS REQUIRED            REFERENCED CHANNELS          FROM REQUIRED            SURVEILLANCE      ALLOWABLE FUNCTION          PER FUNCTION            ACTIONA.1            REQUIREMENTS      VALUE
: 1. Reactor Vessel Water          4                      B                SR 3.3.5.3.1 <: 112.65 inches Level - Low Low                                                        SR 3.3.5.3.2 SR 3.3.5.3.3 SR 3.3.5.3.5
: 2. Reactor Vessel Water          2                      c                SR 3.3.5.3.1 s 214.8 inches Level- High                                                            SR 3.3.5.3.2 SR 3.3.5.3.3 SR 3.3.5.3.5
: 3. Condensate Storage Tank      2                      D                SR 3.3.5.3.2 <: 11.6 inches Level- Low                                                            SR 3.3.5.3.4 SR 3.3.5.3.5 DAEC                                          3.3-53                                                Amendment
 
Primary Containment Isolation Instrumentation 3.3.6.1 3.3 INSTRUMENTATION 3.3.6.1 Primary Containment Isolation Instrumentation LCO 3.3.6.1              The primary containment isolation instrumentation for each Function in Table 3.3.6.1-1 shall be OPERABLE.
APPLICABILITY:            According to Table 3.3.6.1-1.
ACTIONS
-------------------------------------------------------NOTE-----------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                            REQUIRED ACTION                    COMPLETION TIME A.      One or more required                A.1      Place channel in trip.      12 hours for channels inoperable.                                                      Functions 2.a, 2.b, 6.b, and 6.c AND 24 hours for Functions other than Functions 2.a, 2.b, and 6.b, and 6.c AND A.2        ----------NOTE---------
Only applicable for Function 7.a.
Inhibit containment        24 hours spray system.
(continued)
DAEC                                              3.3-54                                Amendment 223 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION            COMPLETION TIME B. One or more automatic    B.1    Restore isolation      1 hour Functions with isolation        capability.
capability not maintained.
C. Required Action and      C.1    Enter the Condition    Immediately associated Completion          referenced in Time of Condition A or          Table 3.3.6.1-1 for B not met.                      the channel.
D. As required by Required  D.1    Isolate associated    12 hours Action C.1 and                  main steam line referenced in Table            (MSL).
3.3.6.1-1.
OR D.2.1 Be in MODE 3.          12 hours AND D.2.2 Be in MODE 4.          36 hours E. As required by Required  E.1  Be in MODE 2.          8 hours Action C.1 and referenced in Table 3.3.6.1-1.
(continued)
DAEC                              3.3-55                      Amendment 223 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 ACTIONS (continued)
CONDITION                  REQUIRED ACTION            COMPLETION TIME F. As required by Required      F.1  Isolate the affected    1 hour Action C.1 and                    penetration flow referenced in Table                path(s).
3.3.6.1-1.
G. [Deleted]
H. As required by Required    H.1    Be in MODE 3.            12 hours Action C.1 and referenced in Table        AND 3.3.6.1-1.
H.2      Be in MODE4.            36 hours OR Required Action and associated Completion Time for Condition F not met.
I. As required by Required  1.1      Declare Standby Liquid  1 hour Action C.1 and                    Control (SLC) System referenced in Table                inoperable.
3.3.6.1-1.
OR 1.2      Isolate the Reactor      1 hour Water Cleanup System.
(continued)
DAEC                                3.3-56                    Amendment No. 231 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 ACTIONS (continued)
CONDITION                REQUIRED ACTION                        COMPLETION TIME J. As required by Required J.1  Initiate action to restore        Immediately Action C.1 and                channel to OPERABLE referenced in Table          status.
3.3.6.1-1.
OR J.2    Initiate action to isolate      Immediately the Residual Heat Removal (RHR)
Shutdown Cooling System.
K. As required by          K.1    -----------NOTE------------
Required Action C.1            Only applicable if and referenced in              inoperable channel is Table 3.3.6.1-1.                not in trip.
Declare associated              Immediately Suppression Pool Cooling/Spray subsystem(s) inoperable.
OR K.2    ----------NOTE------------
Only applicable if inoperable channel is in trip.
Declare Primary                Immediately Containment inoperable.
(continued)
DAEC                            3.3-57                                Amendment 223 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 ACTIONS (continued)
CONDITION              REQUIRED ACTION            COMPLETION TIME L. As required by      L.1  Isolate the primary      1 hour Required Action C.1      containment vent and and referenced in        purge penetration flow Table 3.3.6.1-1.        paths.
OR L.2  Establish                1 hour administrative control of the primary containment vent and purge valves using continuous monitoring of alternate instrumentation.
DAEC                          3.3-58                        Amendment 223 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 SURVEILLANCE REQUIREMENTS
----------------------------------------------------N()TES------------------------------------------------------
: 1. Refer to Table 3.3.6.1-1 to determine which SRs apply for each Primary Containment Isolation Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours for Function 5.a; and (b) for up to 6 hours for Functions other than 5.a provided the associated Function maintains isolation capability.
SURVEILLANCE                                        FREQUENCY SR 3.3.6.1.1              Perform CHANNEL CHECK.                                  In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.2                Perform CHANNEL CHECK.                                In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.3                Perform CHANNEL FUNCTIONAL TEST.                      In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.4                Perform CHANNEL FUNCTl()NAL TEST.                      In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.5                Perform CHANNEL CALIBRATl()N.                          In accordance with the Surveillance Frequency Control Program (continued)
DAEC                                            3.3-59                                Amendment 280 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE                          FREQUENCY SR 3.3.6.1.6  Perform CHANNEL CALIBRATION.            In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.7  Perform CHANNEL CALIBRATION.              In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.8    Perform CHANNEL CALIBRATION.            In accordance with the Surveillance Frequency Control Program SR 3.3.6.1.9    Perform LOGIC SYSTEM FUNCTIONAL          In accordance with TEST.                                    the Surveillance Frequency Control Program DAEC                        3.3-60                          Amendment 280 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1(page1of5)
Primary Containment Isolation Instrumentation APPLICABLE                        CONDITIONS MODES OR        REQUIRED        REFERENCED OTHER        CHANNELS            FROM SPECIFIED        PER TRIP        REQUIRED            SURVEILLANCE        ALLOWABLE FUNCTION                CONDITIONS        SYSTEM          ACTION C.1          REQUIREMENTS      VALUE
: 1. Main Steam Line Isolation
: a. Reactor Vessel Water            1,2,3            2                D              SR  3.3.6.1.1    ~    38.3 inches Level - Low Low Low                                                                SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9
: b. Main Steam Line                                    2                E              SR 3.3.6.1.4      ~    821 psig Pressure - Low                                                                    SR 3.3.6.1.5 SR 3.3.6.1.9
: c. Main Steam Line                  1,2,3          2 per              D              SR  3.3.6.1.1    .'.': 138% rated Flow- High                                      MSL                                SR  3.3.6.1.4      steam ftow SR  3.3.6.1.5 SR  3.3.6.1.9
: d. Condenser                      1, 2(a),          2                D              SR 3.3.6.1.4      ~    7.2 inches Backpressure - High                                                                SR 3.3.6.1.8        Hg vacuum 3(a)
SR 3.3.6.1.9
: e. Main Steam Line Tunnel          1,2,3            4                D              SR  3.3.6.1.2    .'.': 205.1&deg;F Temperature - High                                                                SR  3.3.6.1.4 SR  3.3.6.1.7 SR  3.3.6.1.9 f.. Turbine Building                1,2,3            4                D              SR  3.3.6.1.2    .'.': 205.1&deg;F Temperature - High                                                                SR  3.3.6.1.4 SR  3.3.6.1.7 SR  3.3.6.1.9 (continued)
(a) When any turbine stop valve is greater than 90% open or when the key-locked bypass switch is in the NORM Position.
DAEC                                                        3.3-61                                                  Amendment No. 261 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 2 of 5)
Primary Containment Isolation Instrumentation APPLICABLE                        CONDITIONS MODES OR      REQUIRED        REFERENCED OTHER        CHANNELS              FROM SPECIFIED      PER TRIP          REQUIRED          SURVEILLANCE                ALLOWABLE CONDITIONS          SYSTEM          ACTION C.1        REQUIREMENTS                    VALUE FUNCTION
: 2. Primary Containment Isolation 1,2,3              2                  H            SR  3.3.6.1.1  '.".. 165.6 inches
: a. Reactor Vessel Water Level-Low                                                                        SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9 1,2,3            2                  H            SR 3.3.6.1.4    ~2.2    psig
: b. Drywell Pressure - High SR 3.3.6.1.8 SR 3.3.6.1.9 L            SR  3.3.6.1.2    (b}
: c. Offgas Vent Stack -
High Radiation                                                                    SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9 1,2,3                                H            SR  3.3.6.1.2    ~  12.8 mR/hr
: d. Reactor Building Exhaust Shaft -                                                                    SR  3.3.6.1.4 High Radiation                                                                    SR  3.3.6.1.8 SR  3.3.6.1.9 1,2,3                                H            SR  3.3.6.1.2    ~    10.6 mR/hr
: e. Refueling Floor Exhaust Duct -                                                                    SR  3.3.6.1.4 High Radiation                                                                    SR  3.3.6.1.8 SR  3.3.6.1.9
: 3. High Pressure Coolant Injection (HPCI) System Isolation 1,2,3                                F            SR 3.3.6.1.4      ~  409 inches
: a. HPCI Steam Line Flow -
SR 3.3.6.1.8        (inboard)
High SR 3.3.6.1.9      ~ 110 inches (outboard)
(continued)
(b) Allowable value is determined in accordance with the ODAM.
(c) During venting or purging of primary containment.
DAEC                                                          3.3-62                                                      Amendment 223 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 3 of 5)
Primary Containment Isolation Instrumentation APPLICABLE                  CONDITIONS MODES OR  REQUIRED        REFERENCED OTHER    CHANNELS            FROM SPECIFIED  PER TRIP          REQUIRED            SURVEILLANCE    ALLOWABLE FUNCTION          CONDITIONS  SYSTEM          ACTION C.1          REQUIREMENTS    VALUE
: 3. HPCI System Isolation (continued)
: b. HPCI Steam Supply Line    1,2,3        2                  F              SR 3.3.6.1.4      ::. 50 psig and Pressure - Low                                                          SR 3.3.6.1.8        ::: 147.1 psig SR 3.3.6.1.9
: c. HPCI Turbine              1,2,3        2                  F              SR 3.3.6.1.4    ::._2.5 psig Exhaust Diaphragm                                                        SR 3.3.6.1.8 Pressure - High                                                        SR 3.3.6.1.9
: d. Drywell Pressure -        1,2,3                          F              SR 3.3.6.1.4    ::: 2.2 psig High                                                                    SR 3.3.6.1.8 SR 3.3.6.1.9
: e. Suppression Pool          1,2,3                          F              SR  3.3.6.1.2  ::: 153.3&deg;F Area Ambient                                                            SR  3.3.6.1.4 Temperature - High                                                      SR  3.3.6.1.8 SR  3.3.6.1.9
: f. HPCI Leak Detection      1,2,3                          F              SR 3.3.6.1.4      N/A Time Delay                                                              SR 3.3.6.1.8 SR 3.3.6.1.9
: g. Suppression Pool          1,2,3                          F              SR  3.3.6.1.2  .'.". 51.5&deg;F Area Ventilation                                                        SR  3.3.6.1.4 Differential                                                            SR  3.3.6.1.8 Temperature - High                                                      SR  3.3.6.1.9
: h. HPCI Equipment Room      1,2,3                          F              SR  3.3.6.1.2  ::: 178.3&deg;F Temperature - High                                                      SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9
: i. HPCI Room Ventilation    1,2,3                          F              SR  3.3.6.1.2  ::: 51.5&deg;F Differential                                                            SR  3.3.6.1.4 Temperature - High                                                      SR  3.3.6.1.8 SR  3.3.6.1.9 (continued)
DAEC                                              3.3-63                                    Amendment No. 231 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 4 of 5)
Primary Containment Isolation Instrumentation APPLICABLE                  CONDITIONS MODES OR  REQUIRED        REFERENCED OTHER    CHANNELS              FROM SPECIFIED  PER TRIP          REQUIRED            SURVEILLANCE    ALLOWABLE FUNCTION          CONDITIONS  SYSTEM          ACTION C.1          REQUIREMENTS    VALUE
: 4. Reactor Core Isolation Cooling (RCIC) System Isolation
: a. RCIC Steam Line            1,2,3                          F              SR 3.3.6.1.4    ::= 164 inches Flow-High                                                                SR 3.3.6.1.8    (inboard)
SR 3.3.6.1.9    ::= 159 inches (outboard)
: b. RCIC Steam Supply          1,2,3        2                  F            SR 3.3.6.1.4    ::. 50.3 psig Line Pressure - Low                                                      SR 3.3.6.1.8 SR 3.3.6.1.9
: c. RCIC Turbine              1,2,3        2                  F            SR 3.3.6.1.4    ::. 3.3 psig Exhaust Diaphragm                                                        SR 3.3.6.1.6 Pressure - High                                                          SR 3.3.6.1.9
: d. Drywell Pressure -          1,2,3                          F              SR 3.3.6.1.4    ::= 2.2 psig High                                                                      SR 3.3.6.1.8 SR 3.3.6.1.9
: e. RCIC Suppression            1,2,3                          F              SR  3.3.6.1.2  ::: 153.3&deg;F Pool Area Ambient                                                        SR  3.3.6.1.4 Temperature - High                                                        SR  3.3.6.1.8 SR  3.3.6.1.9
: f. RCIC Leak Detection        1,2,3                          F              SR 3.3.6.1.4      N/A Time Delay                                                                SR 3.3.6.1.8 SR 3.3.6.1.9
: g. RCIC Suppression          1,2,3                          F              SR  3.3.6.1.2    .'." 51.5&deg;F Pool Area Ventilation                                                    SR  3.3.6.1.4 Differential                                                            SR  3.3.6.1.8 Temperature - High                                                        SR  3.3.6.1.9
: h. RCIC Equipment Room        1,2,3                          F              SR  3.3.6.1.2    .'." 178.3&deg;F Temperature - High                                                        SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9 RCIC Room                  1,2,3                          F            SR  3.3.6.1.2    .'." 51.5&deg;F Ventilation                                                              SR  3.3.6.1.4 Differential                                                              SR  3.3.6.1.8 Temperature - High                                                        SR  3.3.6.1.9 (continued)
DAEC                                                3.3-64                                                Amendment No. 231 Repaginated by Amendment_
 
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 5 of 5)
Primary Containment Isolation Instrumentation APPLICABLE                            CONDITIONS MODES OR            REQUIRED        REFERENCED OTHER            CHANNELS              FROM PER TRIP                    SURVEILLANCE          ALLOWABLE SPECIFIED                              REQUIRED SYSTEM          ACTION C.1  REQUIREMENTS        VALUE FUNCTION                        CONDITIONS
: 5. Reactor Water Cleanup (RWCU) System Isolation 1,2,3                                    F    SR  3.3.6.1.2  _'.':59 gpm
: a. Differential Flow -
SR  3.3.6.1.4 High SR  3.3.6.1.8 SR  3.3.6.1.9
: b. Area Temperature - High                        1,2,3                                  F    SR  3.3.6.1.2  .'.': 133.3&deg;F SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9
: c. Area Ventilation                              1,2,3                                  F    SR  3.3.6.1.2 SR  3.3.6.1.4 Differential Temperature - High                                                                          SR  3.3.6.1.8 SR  3.3.6.1.9 RWCU    Pump Room                                                                                          .'.': 22.5&deg;F RWCU    Pump A Room                                                                                        _'.':23.5&deg;F RWCU    Pump B Room                                                                                        .'.': 34.5&deg;F RWCU    Heat Exch. Room                                                                                    .'.': 51.5&deg;F 1,2                                        SR 3.3.6.1.9      NA
: d. SLC System Initiation 1,2,3                2                  F    SR  3.3.6.1.1    ."'._ 112.65
: e. Reactor Vessel Water SR  3.3.6.1.4    inches Level - Low Low SR  3.3.6.1.7 SR  3.3.6.1.9
: f. Area Near TIP Room                              1,2,3                                  F    SR  3.3.6.1.2    .'.': 115.?&deg;F Ambient Temperature -                                                                      SR  3.3.6.1.4 SR  3.3.6.1.8 High SR  3.3.6.1.9
: 6. Shutdown Cooling System Isolation 1,2,3                                  F    SR 3.3.6.1.4      .'.': 152.7 psig
: a. Reactor Steam Dome Pressure - High                                                                            SR 3.3.6.1.5 SR 3.3.6.1.9 3                2                  J    SR  3.3.6.1.1    ."'.. 165.6 inches
: b. Reactor Vessel Water Level-Low                                                                                  SR  3.3.6.1.4 SR  3.3.6.1.8 SR  3.3.6.1.9 1,2,3                2                  F    SR 3.3.6.1.4      .'.': 2.2 psig
: c. Drywell Pressure -
SR 3.3.6.1.8 High SR 3.3.6.1.9
: 7. Containment Cooling System Isolation 1,2,3              4                  K    SR 3.3.6.1.3        ."'.. 1.25 psig
: a. Containment Pressure -
SR 3.3.6.1.8 High SR 3.3.6.1.9 (d) Each Trip System must have either an OPERABLE Function 5.b or an OPERABLE Function 5.c channel in both the RWCU pump area and in the RWCU heat exchanger area.
(e) SLC System Initiation only inputs into one of the two trip systems.
DAEC                                                              3.3-65                                                          Amendment
 
Secondary Containment Isolation Instrumentation 3.3.6.2 3.3 INSTRUMENTATION 3.3.6.2 Secondary Containment Isolation Instrumentation LCO 3.3.6.2              The secondary containment isolation instrumentation for each Function in Table 3.3.6.2-1 shall be OPERABLE.
APPLICABILITY:            According to Table 3.3.6.2-1.
ACTIONS
-------------------------------------NOTE----------------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                        REQUIRED ACTION                      COMPLETION TIME A. One or more channels              A.1      Place channel in trip.            12 hours for inoperable.                                                                  Functions 1 and 2 AND 24 hours for Functions 3 and 4 B. One or more Functions            B.1      Restore secondary                1 hour with secondary                            containment isolation containment isolation                      capability.
capability not maintained.
(continued)
DAEC                                          3.3-66                                  Amendment 223 Repaginated by Amendment_
 
Secondary Containment Isolation Instrumentation 3.3.6.2 ACTIONS (continued)
CONDITION                REQUIRED ACTION            COMPLETION TIME C. Required Action and    C.1.1  Isolate secondary      1 hour associated Completion          containment.
Time of Condition A or B not met.                OR C.1.2  Declare associated      1 hour Secondary Containment Isolation Valves/Dampers (SCIV/Ds) inoperable.
C.2.1 Place the associated      1 hour Standby Gas Treatment (SBGT) subsystem(s) in operation.
1 hour C.2.2 Declare associated SBGT subsystem(s) inoperable.
DAEC                              3.3-67                        Amendment 223 Repaginated by Amendment_
 
Secondary Containment Isolation Instrumentation 3.3.6.2 SURVEILLANCE REQUIREMENTS
----------------------------------------------------N()TES-----------------------------------------------------
: 1. Refer to Table 3.3.6.2-1 to determine which SRs apply for each Secondary Containment Isolation Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours provided the associated Function maintains secondary containment isolation capability.
SURVEILLANCE                                        FREQUENCY SR 3.3.6.2.1                  Perform CHANNEL CHECK.                                In accordance with the Surveillance Frequency Control Program SR 3.3.6.2.2                  Perform CHANNEL CHECK.                                In accordance with the Surveillance Frequency Control Program SR 3.3.6.2.3                Perform CHANNEL FUNCTl()NAL TEST.                    In accordance with the Surveillance Frequency Control Program SR 3.3.6.2.4                Perform CHANNEL CALIBRATl()N.                        In accordance with the Surveillance Frequency Control Program SR 3.3.6.2.5                Perform L()GIC SYSTEM FUNCTl()NAL                    In accordance with TEST.                                                the Surveillance Frequency Control Program DAEC                                              3.3-68                                Amendment 280 Repaginated by Amendment_
 
Secondary Containment Isolation Instrumentation 3.3.6.2 Table 3.3.6.2-1 (page 1 of 1)
Secondary Containment Isolation Instrumentation APPLICABLE MODES OR      REQUIRED OTHER        CHANNELS SPECIFIED        PER              SURVEILLANCE            ALLOWABLE FUNCTION        CONDITIONS    TRIP SYSTEM          REQUIREMENTS          VALUE
: 1. Reactor Vessel Water        1,2,3            2            SR  3.3.6.2.1          ~    165.6 inches Level - Low                                                SR  3.3.6.2.3 SR  3.3.6.2.4 SR  3.3.6.2.5
: 2. Drywell Pressure - High    1,2,3            2            SR 3.3.6.2.3            .'.': 2.2 psig SR 3.3.6.2.4 SR 3.3.6.2.5
: 3. Reactor Building Exhaust    1,2,3                          SR  3.3.6.2.2          .'.': 12.8 mR/hr Shaft - High Radiation                                      SR  3.3.6.2.3 SR  3.3.6.2.4 SR  3.3.6.2.5
: 4. Refueling Floor Exhaust    1,2,3                          SR  3.3.6.2.2          .'.': 10.6 mR/hr Duct - High Radiation                                      SR  3.3.6.2.3 SR  3.3.6.2.4 SR  3.3.6.2.5 DAEC                                              3.3-69                                                Amendment
 
LLS Instrumentation 3.3.6.3 3.3 INSTRUMENTATION 3.3.6.3 Low-Low Set (LLS) Instrumentation LCO 3.3.6.3            The LLS valve instrumentation for each Function in Table 3.3.6.3-1 shall be OPERABLE.
APPLICABILITY:          MODES 1, 2, and 3.
ACTIONS CONDITION                        REQUIRED ACTION            COMPLETION TIME A. One LLS valve                    A.1    Restore channel(s) to    24 hours inoperable due to                        OPERABLE status.
inoperable channel(s).
B. One or more Safety                B.1    Restore channel(s) to    Prior to entering    I Relief Valves (SRVs)                    OPERABLE status.        MODE 2 or 3 from with one Function 3                                              MODE4 channel inoperable.
C.    -------------NOTE------------ C.1        Restore at least two    14 days Separate Condition entry                channels per SRV to is allowed for each SRV.                OPERABLE status.
One or more SRVs with two or more Function 3 channels inoperable.
(continued)
DAEC                                        3.3-70                        Amendment 255 Repaginated by Amendment_
 
LLS Instrumentation 3.3.6.3 ACTIONS (continued)
CONDITION                            REQUIRED ACTION                COMPLETION TIME D.      Required Action and                  D.1    Declare the                  Immediately associated Completion                        associated LLS Time of Condition A, B,                      valve(s) inoperable.
or C not met.
OR Both LLS valves inoperable due to inoperable channels.
SURVEILLANCE REQUIREMENTS
-----------------------------------------------------NOTES-----------------------------------------------------
: 1. Refer to Table 3.3.6.3-1 to determine which SRs apply for each Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours provided the associated Function maintains LLS initiation capability.
SURVEILLANCE                                          FREQUENCY SR 3.3.6.3.1                Perform CHANNEL FUNCTIONAL TEST for                      In accordance portion of the channel outside primary                    with the containment.                                              Surveillance Frequency Control Program SR 3.3.6.3.2              Perform CHANNEL FUNCTIONAL TEST.                          In accordance with the Surveillance Frequency Control Program (continued)
DAEC                                              3.3-71                            Amendment 280 Repaginated by Amendment_
 
LLS Instrumentation 3.3.6.3 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE                            FREQUENCY SR 3.3.6.3.3  Perform CHANNEL CALIBRATION.            In accordance with the Surveillance Frequency Control Program SR 3.3.6.3.4    Perform CHANNEL CALIBRATION.          In accordance with the Surveillance Frequency Control Program SR 3.3.6.3.5    Perform CHANNEL CALIBRATION.            In accordance with the Surveillance Frequency Control Program SR 3.3.6.3.6    Perform LOGIC SYSTEM FUNCTIONAL        In accordance TEST.                                  with the Surveillance Frequency Control Program DAEC                        3.3-72                  Amendment 280 Repaginated by Amendment_
 
LLS Instrumentation 3.3.6.3 Table 3.3.6.3-1 (page 1 of 1)
Low-Low Set Instrumentation REQUIRED CHANNELS PER              SURVEILLANCE  ALLOWABLE FUNCTION              REQUIREMENTS  VALUE FUNCTION 1 per LLS valve          SR 3.3.6.3.2  '."'. 1069.21 psig
: 1. Reactor Vessel Steam Dome Pressure - High                                          SR 3.3.6.3.3 SR 3.3.6.3.6 2 per LLS valve          SR 3.3.6.3.2    Low:
: 2. Low-Low Set Pressure Setpoints SR 3.3.6.3.4          Open~    1014 psig SR 3.3.6.3.6              and '."'. 1 045 psig Close~ 893.4 psig and '."'. 925 psig High:
Open~      1019 psig and '."'. 1050 psig Close ~ 893.4 psig and '."'. 930 psig 3 perSRV              SR 3.3.6.3.1    '."'. 99 psig
: 3. Tailpipe High Pressure SR 3.3.6.3.5 SR 3.3.6.3.6 DAEC                                            3.3-73                                        Amendment 223 Repaginated by Amendment_
 
SFU System Instrumentation 3.3.7.1 3.3 INSTRUMENTATION 3.3.7.1 Standby Filter Unit (SFU) System Instrumentation LCO 3.3.7.1              Two channels of the Control Building Intake Area Radiation - High Function shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE ALTERATIONS.
ACTIONS
------------------------------------------------NOTE--------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                            REQUIRED ACTION                      COMPLETION TIME A. One or both channels                  A.1    Declare associated                1 hour inoperable.                                  SFU subsystem(s) inoperable.
OR A.2      Place associated SFU            1 hour subsystem(s) in the isolation mode.
DAEC                                            3.3-74                                          Amendment
 
SFU System Instrumentation 3.3.7.1 SURVEILLANCE REQUIREMENTS
-----------------------------------------------------N()TE---------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours provided the other channel is ()PERABLE.
SURVEILLANCE                                          FREQUENCY SR 3.3.7.1.1                Perform CHANNEL CHECK.                                    In accordance with the Surveillance Frequency Control Program SR 3.3.7.1.2                Perform CHANNEL FUNCTl()NAL TEST.                          In accordance with the Surveillance Frequency Control Program SR 3.3.7.1.3                Perform CHANNEL CALIBRATl()N. The                          In accordance Allowable Value shall be :::; 5 mR/hr.                    with the Surveillance Frequency Control Program SR 3.3.7.1.4                Perform L()GIC SYSTEM FUNCTl()NAL                          In accordance TEST.                                                      with the Surveillance Frequency Control Program DAEC                                              3.3-75                                Amendment 280 Repaginated by Amendment_
 
LOP Instrumentation 3.3.8.1 3.3 INSTRUMENTATION 3.3.8.1 Loss of Power (LOP) Instrumentation LCO 3.3.8.1              The LOP instrumentation for each Function in Table 3.3.8.1-1 shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3, When the associated Diesel Generator is required to be OPERABLE by LCO 3.8.2, "AC Sources - Shutdown."
ACTIONS
--------------------------------------------------------NOTE---------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION                            REQUIRED ACTION                    COMPLETION TIME A.      One or more Function 1              A.1      Place channel in trip.        1 hour or 3 channels inoperable.
B.      One or more Function 2              B.1      Declare associated            1 hour from discovery channels inoperable.                        Diesel Generator (DG)        of loss of initiation inoperable.                  capability for feature(s) in one or both divisions AND                                    24 hours B.2      Place channel in trip.
(continued)
DAEC                                              3.3-76                              Amendment 223 Repaginated by Amendment_
 
LOP Instrumentation 3.3.8.1 ACTIONS (continued)
CONDITION              REQUIRED ACTION            COMPLETION TIME C. Required Action and  C.1    Declare associated DG  Immediately associated Completion        inoperable.
Time not met.
DAEC                          3.3-77                        Amendment 223 Repaginated by Amendment_
 
LOP Instrumentation 3.3.8.1 SURVEILLANCE REQUIREMENTS
----------------------------------------------------NOTES-----------------------------------------------------
: 1. Refer to Table 3.3.8.1-1 to determine which SRs apply for each LOP Function.
: 2. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 2 hours provided the associated Function maintains DG initiation capability.
SURVEILLANCE                                        FREQUENCY SR 3.3.8.1.1                  Perform CHANNEL FUNCTIONAL TEST.                        In accordance with the Surveillance Frequency Control Program SR 3.3.8.1.2                  Perform CHANNEL FUNCTIONAL TEST.                        In accordance with the Surveillance Frequency Control Program SR 3.3.8.1.3                  Perform CHANNEL CALIBRATION.                            In accordance with the Surveillance Frequency Control Program SR 3.3.8.1.4                  Perform CHANNEL CALIBRATION.                            In accordance with the Surveillance Frequency Control Program SR 3.3.8.1.5                  Perform LOGIC SYSTEM FUNCTIONAL                        In accordance with TEST.                                                  the Surveillance Frequency Control Program DAEC                                              3.3-78                              Amendment 280 Repaginated by Amendment_
 
LOP Instrumentation 3.3.8.1 Table 3.3.8.1-1 (page 1 of 1)
Loss of Power Instrumentation REQUIRED CHANNELS            SURVEILLANCE          ALLOWABLE FUNCTION              PER BUS            REQUIREMENTS          VALUE
: 1. 4.16 kV Emergency Bus Undervoltage (Loss of Voltage)
: a. Bus Undervoltage                                  SR 3.3.8.1.2            :'.'.. 595 Vand SR 3.3.8.1.4            _:::2275 v SR 3.3.8.1.5
: 2. 4.16 kV Emergency Bus Undervoltage (Degraded Voltage)
: a. Bus Undervoltage                  4              SR 3.3.8.1.1            :'.'.. 3780 Vand SR 3.3.8.1.3            _:::3822V SR 3.3.8.1.5
: b. Time Delay                        4              SR 3.3.8.1.1            :'.'.. 7.92 seconds and SR 3.3.8.1.3            ::: 8.5 seconds SR 3.3.8.1.5
: 3. 4.16 kV Emergency Transformer          2              SR 3.3.8.1.2            :'.'._2450V Supply Undervoltage                                  SR 3.3.8.1.3 SR 3.3.8.1.5 DAEC                                              3.3-79                                          Amendment 273 Repaginated by Amendment_
 
RPS Electric Power Monitoring 3.3.8.2 3.3 INSTRUMENTATION 3.3.8.2 Reactor Protection System (RPS) Electric Power Monitoring LCO 3.3.8.2        Two RPS Electrical Protection Assemblies (EPAs) shall be OPERABLE for each inservice RPS motor generator set or alternate power supply.
APPLICABILITY:      MODES 1 and 2, MODES 3, 4 and 5 with any control rod withdrawn from a core cell containing one or more fuel assemblies.
ACTIONS CONDITION                  REQUIRED ACTION            COMPLETION TIME A. One or both inservice      A.1    Remove associated      72 hours power supplies with one          inservice power EPA inoperable.                  supply(s) from service.
B. One or both inservice      B.1    Remove associated      1 hour power supplies with              inservice power both EPAs inoperable.            supply(s) from service.
C. Required Action and        C. 1    Be in MODE 3.          12 hours associated Completion Time of Condition A or B not met in MODE 1 or 2.
(continued)
DAEC                                  3.3-80                        Amendment 223 Repaginated by Amendment_
 
RPS Electric Power Monitoring 3.3.8.2 ACTIONS (continued)
CONDITION                          REQUIRED ACTION                  COMPLETION TIME D. Required Action and                  D.1    Initiate action to fully  Immediately associated Completion Time                  insert all insertable of Condition A or B not met                  control rods in core in MODE 3, 4 or 5 with any                  cells containing one control rod withdrawn from a                or more fuel core cell containing one or                  assemblies.
more fuel assemblies.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                      FREQUENCY SR 3.3.8.2.1    -------------------------NOTE---------------------------
Only required to be performed prior to entering MODE 2 or 3 from MODE 4, when in MODE 4 for z 24 hours.
Perform CHANNEL FUNCTIONAL TEST.                        In accordance with the Surveillance Frequency Control Program SR 3.3.8.2.2    Perform CHANNEL CALIBRATION. The                        In accordance with the Allowable Values shall be:                              Surveillance Frequency Control Program
: a. Overvoltage      ~  132 V.
: b. Undervoltage      z 108 V.
: c. Underfrequency z 57 Hz.
SR 3.3.8.2.3    Perform a system functional test.                        In accordance with the Surveillance Frequency Control Program DAEC                                      3.3-81                            Amendment 280 Repaginated by Amendment_
 
EGGS- Operating 3.5.1 3.5 EMERGENCY CORE COOLING SYSTEMS (EGGS), RPV WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM 3.5.1 EGGS -        Operating LCO 3.5.1                Each EGGS injection/spray subsystem and the Automatic Depressurization System (ADS) function of four safety/relief valves shall be OPERABLE.
APPLICABILITY:            MODE 1, MODES 2 and 3, except High Pressure Coolant Injection (HPCI) is not required to be OPERABLE with reactor steam dome pressure ~ 150 psig and ADS valves are not required to be OPERABLE with reactor steam dome pressure~ 100 psig.
ACTIONS
--------------------------------------------------------NOTE----------------------------------------------------
LCO 3.0.4.b is not applicable to HPCI.
CONDITION                            REQUIRED ACTION                    COMPLETION TIME A.      One Residual Heat                  A.1      Restore RHR pump to          30 Days Removal (RHR) pump                          OPERABLE status.
inoperable.
B.      One low pressure EGGS B.1                    Restore low pressure          7 days subsystem inoperable for                    EGGS subsystem to reasons other than                          OPERABLE status.
Condition A.
C.      One Core Spray                      C.1      Restore Core Spray            72 hours subsystem inoperable.                        subsystem to OPERABLE status.
AND One or two RHR                      OR pump(s) inoperable.                                                        72 hours C.2      Restore RHR pump(s) to OPERABLE status.
D.      Both Core Spray                      D.1    Restore one Core              72 hours subsystems inoperable.                        Spray subsystem to OPERABLE status.
(continued)
DAEC                                              3.5-1                                    Amendment
 
RPV Water Inventory Control 3.5.2 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS), RPV WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM 3.5.2 Reactor Pressure Vessel (RPV) Water Inventory Control LCO 3.5.2          DRAIN TIME of RPV water inventory to the top of active fuel (TAF) shall be ~ 36 hours.
AND One low pressure ECCS subsystems shall be OPERABLE.
APPLICABILITY:    MODES 4 and 5.
ACTIONS CONDITION                  REQUIRED ACTION              COMPLETION TIME A. Required ECCS              A.1    Restore required          4 hours subsystem inoperable.            ECCS subsystem to OPERABLE status.
B. Required Action and        B.1    Initiate action to        Immediately associated Completion            establish a method of Time of Condition A              water injection capable not met.                          of operating without offsite electrical power.
(continued)
DAEC                                  3.5-8                              Amendment
 
RPV Water Inventory Control 3.5.2 ACTIONS (continued)
CONDITION              REQUIRED ACTION            COMPLETION TIME C. DRAIN TIME < 36 hours C.1  Verify secondary          4 hours and > 8 hours.            containment boundary is capable of being established in less than the DRAIN TIME.
AND C.2  Verify each secondary    4 hours containment penetration flow path is capable of being isolated in less than the DRAIN TIME.
AND C.3  Verify one standby gas  4 hours treatment subsystem is capable of being placed in operation in less that the DRAIN TIME.
(continued)
DAEC                          3.5-9                            Amendment
 
RPV Water Inventory Control 3.5.2 ACTIONS (Continued)
D. DRAIN TIME< 8 D.1  ---------- NOTE ----------
hours.              Required ECCS injection/spray subsystem or additional method of water injection shall be capable of operating without offsite electrical power.
Initiate action to            Immediately establish an additional method of water injection with water sources capable of maintaining RPV water level > TAF for .::: 36 hours.
AND D.2  Initiate action to            Immediately establish secondary containment boundary.
AND D.3 Initiate action to isolate      Immediately each secondary containment penetration flow path or verify it can be manually isolated from the control room.
AND D.4 Initiate action to verify      Immediately one standby gas treatment subsystem is capable of being placed in operation.
(continued)
DAEC                    3.5-10                              Amendment
 
RPV Water Inventory Control 3.5.2 ACTIONS (Continued)
E.      Required Action and        E.1    Initiate action to      Immediately associated Completion            restore DRAIN TIME Time of Condition C or            to > 36 hours.
D not met.
DRAIN TIME< 1 hour.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                FREQUENCY SR 3.5.2.1        Verify DRAIN TIME .:::_ 36 hours.            In accordance with the Surveillance Frequency Control Program SR 3.5.2.2        Verify, for a required Low Pressure          In accordance with Coolant Injection (LPCI) subsystem, the      the Surveillance suppression pool water level is~ 7.0 ft.      Frequency Control Program (continued)
DAEC                                  3.5-11                            Amendment
 
RPV Water Inventory Control 3.5.2 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE                                        FREQUENCY SR 3.5.2.3  Verify, for a required Core Spray (CS)                      In accordance subsystem, the:                                              with the Surveillance
: a. Suppression pool water level is ;:::: 8.0 ft; or      Frequency Control Program
: b. Condensate storage tank water level in one CST is 2: 11 ft or 2: 7 ft in both CSTs.
SR 3.5.2.4  Verify, for the required ECCS injection/spray                In accordance subsystem, locations susceptible to gas                      with the accumulation are sufficiently filled with water.            Surveillance Frequency Control Program SR 3.5.2.5  ---------------------------N()TE----------------------------
A LPCI subsystem may be considered
()PERABLE during alignment and operation for decay heat removal if capable of being manually realigned and not otherwise inoperable.
            ---------------------------N()TE----------------------------
Not required to be met for system vent flow paths opened under administrative control.
Verify for the required ECCS subsystem,                      In accordance each power operated and automatic valve in                  with the the flow path, that is not locked, sealed, or                Surveillance otherwise secured in position, is in the                    Frequency correct position.                                            Control Program (continued)
DAEC                                  3.5-12                              Amendment
 
RPV Water Inventory Control 3.5.2 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE                                        FREQUENCY SR 3.5.2.6  Operate the required ECCS injection/spray subsystem          In through the recirculation line for_::: 10 minutes.            accordance with the lnservice Testing Program SR 3.5.2.7  Verify each valve credited for automatically isolating a      In accordance penetration flow path actuates to the isolation position on  with the an actual or simulated isolation signal.                      Surveillance Frequency Control Program DAEC                            3.5-13                                Amendment
 
RCIC System 3.5.3 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS), RPV WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM 3.5.3 RCIC System LCO 3.5.3                The RCIC System shall be OPERABLE.
APPLICABILITY:            MODE 1, MODES 2 and 3 with reactor steam dome pressure > 150 psig.
ACTIONS
----------------------------------------------------NOTE----------------------------------------------------
LCO 3.0.4.b is not applicable to RCIC.
CONDITION                            REQUIRED ACTION                  COMPLETION TIME A.      RCIC System                        A.1    Verify by administrative      Immediately inoperable.                                means High Pressure Coolant Injection System is OPERABLE.
AND A.2    Restore RCIC System            14 days to OPERABLE status.
B. Required Action and                B.1    Be in MODE 3.                  12 hours associated Completion Time not met.                      AND B.2    Reduce reactor                36 hours steam dome pressure to~ 150 psig.
DAEC                                              3.5-14                                    Amendment
 
RCIC System 3.5.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE                                        FREQUENCY SR 3.5.3.1  Verify the RCIC System locations susceptible                  In accordance to gas accumulation are sufficiently filled with              with the water.                                                        Surveillance Frequency Control Program SR 3.5.3.2  ----------------------------N()TE---------------------------
Not required to be met for system vent flow paths opened under administrative control.
Verify each RCIC System power operated and                    In accordance automatic valve in the flow path, that is not                with the locked, sealed, or otherwise secured in position,            Surveillance is in the correct position.                                  Frequency Control Program SR 3.5.3.3  -----------------------------N()TE---------------------------
Not required to be performed until 12 hours after reactor steam pressure and flow are adequate to perform the test.
Verify, with reactor pressure s; 1025 psig and                In accordance
            ;::: 940 psig, the RCIC pump can develop a flow              with the rate ;::: 400 gpm against a system head                      lnservice Testing corresponding to reactor pressure.                            Program SR 3.5.3.4  ---------------------------N()TE-----------------------------
Not required to be performed until 12 hours after reactor steam pressure and flow are adequate to perform the test.
Verify, with reactor pressures; 160 psig, the                In accordance RCIC pump can develop a flow rate ;::: 400                  with the gpm against a system head corresponding to                    Surveillance reactor pressure.                                            Frequency Control Program (continued)
DAEC                                  3.5-15                        Amendment 290 Repaginated by Amendment_
 
RCIC System 3.5.3 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE                                          FREQUENCY SR 3.5.3.5  ---------------------------N()TE----------------------------
Vessel injection may be excluded.
Verify the RCIC System actuates on an actual                  In accordance or simulated automatic initiation signal.                    with the Surveillance Frequency Control Program DAEC                                  3.5-16                            Amendment 280 Repaginated by Amendment_
 
PC IVs 3.6.1.3 3.6 CONTAINMENT SYSTEMS 3.6.1.3 Primary Containment Isolation Valves (PCIVs)
LCO 3.6.1.3                Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3.
ACTIONS
-------------------------------------------------------NOTES--------------------------------------------------
: 1. Penetration flow paths may be unisolated intermittently under administrative controls.
: 2. Separate Condition entry is allowed for each penetration flow path.
: 3.      Enter applicable Conditions and Required Actions for systems made inoperable by PC IVs.
: 4.      Enter applicable Conditions and Required Actions of LCO 3.6.1.1, "Primary Containment," when PCIV leakage results in exceeding overall containment leakage rate acceptance criteria in MODES 1, 2, and 3.
CONDITION                          REQUIRED ACTION                COMPLETION TIME A.      -------------NOTE-----------      A.1      Isolate the affected        4 hours except for Only applicable to                          penetration flow path        main steam line penetration flow paths                      by use of at least one with two PCIVs.                            closed and de-              AND
          --------------------------------            activated automatic valve, closed manual        8 hours for main One or more                                valve, blind flange, or      steam line penetration flow paths                      check valve with flow with one PCIV                              through the valve inoperable except for                      secured.
MSIV or purge valve leakage not within limits.        AND (continued)
DAEC                                              3.6-8                                    Amendment
 
PC IVs 3.6.1.3 ACTIONS CONDITION                  REQUIRED ACTION                  COMPLETION TIME E.  (continued)              E.3  ----------NOTES----------
: 2. Isolation devices that are locked, sealed, or otherwise secured may be verified by use of administrative means.
Verify the affected            Once per 31 days for penetration flow path is        isolation device isolated.                      outside containment 12 hours F. Required Action and    F.1    Be in MODE 3.
associated Completion  AND Time of Condition A, B,                                        36 hours C, D, or E not met. F.2    Be in MODE4.
DAEC                            3.6-12                                Amendment No.
 
Secondary Containment 3.6.4.1 3.6 CONTAINMENT SYSTEMS 3.6.4.1 Secondary Containment LCO 3.6.4.1        The secondary containment shall be OPERABLE.
APPLICABILITY:    MODES 1, 2, and 3.
ACTIONS CONDITION                REQUIRED ACTION          COMPLETION TIME A. Secondary containment    A.1    Restore secondary    4 hours inoperable.                    containment to OPERABLE status.
B. Required Action and      B.1    Be in MODE 3.        12 hours associated Completion Time of Condition A not  AND met.
B.2    Be in MODE 4.        36 hours (continued)
DAEC                                3.6-35                        Amendment
 
SCIV/Ds 3.6.4.2 3.6 CONTAINMENT SYSTEMS 3.6.4.2 Secondary Containment Isolation Valves/Dampers (SCIV/Ds)
LCO 3.6.4.2              Each SCIV/D shall be OPERABLE.
APPLICABILITY:            MODES 1, 2, and 3.
ACTIONS
--------------------------------------------------------NOTES--------------------------------------------------
: 1. Penetration flow paths may be unisolated intermittently under administrative controls.
: 2. Separate Condition entry is allowed for each penetration flow path.
: 3. Enter applicable Conditions and Required Actions for systems made inoperable by SCIV/Ds.
CONDITION                            REQUIRED ACTION                  COMPLETION TIME A.        One or more                      A.1      Isolate the affected        8 hours penetration flow                            penetration flow path paths with one                              by use of at least one SCIV/D inoperable.                          closed and de-activated automatic valve/damper, closed manual valve, or blind flange.
AND (continued)
DAEC                                              3.6-37                                    Amendment
 
SCIV/Ds 3.6.4.2 ACTIONS CONDITION                        REQUIRED ACTION                    COMPLETION TIME A.  (continued)                        A.2  -----------NOTES------------
: 1. Isolation devices in high radiation areas may be verified by use of administrative means.
: 2. Isolation devices that are locked, sealed, or otherwise secured may be verified by use of administrative means.
Verify the affected              Once per 31 days penetration flow path is isolated.
B.  -------------NOTE--------------    B.1  Isolate the affected              4 hours Only applicable to                      penetration flow path penetration flow paths                  by use of at least one with two isolation                      closed and de-valves/dampers.                        activated automatic
    -----------------------------------      valve/damper, closed manual valve, or blind One or more                              flange.
penetration flow paths with two SCIV/Ds inoperable.
(continued)
DAEC                                      3.6-38                                    Amendment
 
SCIV/Ds 3.6.4.2 ACTIONS (continued)
C. Required Action and    C.1    Be in MODE 3. 12 hours associated Completion Time of Condition A or AND B not met in MODE 1, 2, or 3.                C.2    Be in MODE 4. 36 hours DAEC                          3.6-39                  Amendment
 
SBGT System 3.6.4.3 3.6 CONTAINMENT SYSTEMS 3.6.4.3 Standby Gas Treatment (SBGT) System LCO 3.6.4.3        Two SBGT subsystems shall be OPERABLE.
APPLICABILITY:    MODES 1, 2, and 3.
ACTIONS CONDITION                  REQUIRED ACTION      COMPLETION TIME A. One SBGT subsystem      A.1    Restore SBGT      7 days inoperable.                    subsystem to OPERABLE status.
B. Required Action and      B.1    Be in MODE 3.      12 hours associated Completion Time of Condition A not AND met.
B.2    Be in MODE4.      36 hours (continued)
DAEC                                3.6-41                      Amendment
 
SBGT System 3.6.4.3 ACTIONS CONDITION            REQUIRED ACTION      COMPLETION TIME C. Two SBGT subsystems C.1    Enter LCO 3.0.3. Immediately inoperable.
DAEC                        3.6-42                Amendment
 
SFU System 3.7.4
: 3. 7 PLANT SYSTEMS 3.7.4 Standby Filter Unit (SFU) System LCO 3.7.4                Two SFU subsystems shall be OPERABLE.
-------------------------------------------------------NOTE--------------------------------------------------
The control building envelope (CBE) boundary may be opened intermittently under administrative control.
APPLICABILITY:            MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE AL TERATIONS.
ACTIONS CONDITION                            REQUIRED ACTION                      COMPLETION TIME A.      One SFU subsystem                  A.1      Restore SFU subsystem          7 days inoperable for reasons                      to OPERABLE status.
other than Condition B.
B.      One or more SFU                    B.1      Initiate actions to            Immediately subsystems                                  implement mitigating inoperable due to                            actions.
inoperable CBE                    AND boundary in MODES 1, 2, and 3.                      B.2      Verify mitigating actions      24 hours ensure CBE occupant exposures to radiological hazards will not exceed limits and verify by administrative means that CBE occupants are protected from smoke and chemical hazards.
AND B.3      Restore CBE boundary            90 days to OPERABLE status.
(continued)
DAEC                                              3.7-7                              Amendment No.
 
SFU System 3.7.4 ACTIONS (continued)
CONDITION                    REQUIRED ACTION                    COMPLETION TIME C. Required Action and        C.1      Be in MODE 3.                    12 hours associated Completion Time of Condition A or    AND B not met in MODE 1, C.2      Be in MODE 4.                    36 hours 2, or 3.
D. Required Action and      ------------------NOTE---------------
associated Completion    LCO 3.0.3 is not applicable.
Time of Condition A      -----------------------------------------
not met during D.1      Place OPERABLE SFU              Immediately movement of subsystem in the irradiated fuel isolation mode.
assemblies in the OR secondary containment during D.2.1 Suspend movement of                Immediately I
CORE ALTERATIONS.
irradiated fuel                                    I assemblies in the secondary containment.
AND D.2.2 Suspend CORE                        Immediately ALTERATIONS.
E. Both SFU subsystems      E.1      Enter LCO 3.0.3                Immediately inoperable in MODE 1, 2 or 3 for reasons other than Condition B.
(continued)
DAEC                                3.7-8                                Amendment No.
 
SFU System 3.7.4 ACTIONS (continued)
CONDITION                      REQUIRED ACTION                COMPLETION TIME F. Both SFU subsystems      ----------------NOTE----------------
inoperable during        LCO 3.0.3 is not applicable.
movement of irradiated fuel assembles in the secondary containment    F. 1 Suspend movement of              Immediately during CORE                      irradiated fuel assemblies ALTERATIONS.                    in the secondary containment.
OR One or more SFU subsystems inoperable    F .2 Suspend CORE                    Immediately due to an inoperable            ALTERATIONS.
CBE boundary during movement of irradiated fuel assemblies in the secondary containment during CORE ALTERATIONS.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                    FREQUENCY SR 3.7.4.1        Operate each SFU subsystem for                      In accordance with the
                  ~ 15 minutes.                                      Surveillance Frequency Control Program SR 3.7.4.2        Perform required SFU filter testing in              In accordance with the accordance with the Ventilation Filter Testing      VFTP Program (VFTP).
(continued)
DAEC                                  3.7-9                                Amendment
 
CBC System 3.7.5 3.7 PLANT SYSTEMS 3.7.5 Control Building Chiller (CBC) System LCO 3.7.5          Two CBC subsystems shall be OPERABLE.
APPLICABILITY:      MODES 1, 2, and 3, During movement of irradiated fuel assemblies in the secondary containment, During CORE AL TERATIONS.
ACTIONS CONDITION                  REQUIRED ACTION            COMPLETION TIME A. One CBC subsystem          A.1    Restore CBC              30 days inoperable.                        subsystem to OPERABLE status.
B. Two CBC subsystems          B.1    Verify control building  Once per 4 hours inoperable.                        area temperatures
                                          < 90&deg;F.
AND B.2    Restore one CBC          72 hours subsystem to OPERABLE status.
C. Required Action and        C. 1    Be in MODE 3.            12 hours associated Completion Time of Condition A or B    AND not met in MODE 1, 2, or 3.                      C.2      Be in MODE 4.          36 hours (continued)
DAEC                                  3.7-11                            Amendment
 
CBC System 3.7.5 ACTIONS (continued)
CONDITION                REQUIRED ACTION                COMPLETION TIME D. Required Action and  ------------------NOTE---------------
associated Completion LCO 3.0.3 is not applicable.
Time of Condition A not met during        D.1      Place OPERABLE CBC          Immediately movement of                    subsystem in operation.
irradiated fuel assemblies in the    OR secondary containment during    D.2.1 Suspend movement of            Immediately CORE                            irradiated fuel ALTERATIONS.                    assemblies in the secondary containment.
AND D.2.2 Suspend CORE                    Immediately ALTERATIONS.
(continued)
DAEC                            3.7-12                                Amendment
 
CBC System 3.7.5 ACTIONS (continued)
CONDITION                      REQUIRED ACTION                      COMPLETION TIME E. Required Action and          ------------------NOTE---------------
associated Completion        LCO 3.0.3 is not applicable.
Time of Condition B not      -----------------------------------------
met during movement          E.1      Suspend movement                Immediately of irradiated fuel                    of irradiated fuel assemblies in the                      assemblies in the secondary containment                  secondary during CORE                            containment.
ALTERATIONS.
AND E.2      Suspend CORE                    Immediately ALTERATIONS.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                          FREQUENCY SR 3.7.5.1          Verify each CBC subsystem has the                      In accordance with the capability to remove the available heat load.          Surveillance Frequency Control Program DAEC                                    3.7-13                                  Amendment
 
AC Sources -        Shutdown 3.8.2 ACTIONS
---------------------------------------------------NOTE------------------------------------~-----------------~~--
LCO 3.0.3 is not applicable.
CONDITION                              REQUIRED ACTION                      COMPLETION TIME A.        One required offsite              ----------------NOTE------------------
circuit inoperable.              Enter applicabl~ Condition and Required Actions of LCO 3.8.8, with one required division de-energized as a result of Condition A.
A.1          Declare affected                Immediately required feature(s),
with no offsite power available, inoperable.
A.2.1        Suspend CORE                    Immediately ALTERATIONS.
AND A.2.2        Suspend movement                Immediately of irradiated fuel assemblies in the secondary containment.
AND A.2.3        Initiate action to restore    Immediately required offsite power circuit t6 OPERABLE status.
(continued)
DAEC                                            3.8-12                                          Amendment
 
AC Sources -    Shutdown 3.8.2 ACTIONS (continued)
CONDITION                          REQUIRED ACTION                  COMPLETION TIME B.      One required DG              B.1      Suspend CORE                  Immediately inoperable.                            ALTERATIONS.
AND B.2      Suspend movement              Immediately of irradiated fuel assemblies in secondary containment AND B.3      Initiate action to            Immediately restore required DG to OPERABLE status.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                          FREQUENCY SR 3.8.2.1        -------------------------NOTES----------------------------
: 1. The following SRs are not required to be performed: SR 3.8.1.3, SR 3.8.1.9 through SR 3.8.1.13.
: 2. SR 3.8.1.13 is considered to be met without the ECCS initiation signals OPERABLE when the ECCS initiation signals are not required to be OPERABLE per Table 3.3.5.1-1.
For AC sources required to be OPERABLE, the                In accordance SRs of Specification 3.8.1, except SR 3.8.1.8,              with applicable are applicable.                                            SRs DAEC                                      3.8-13                                    Amendment
 
DC Sources -      Shutdown 3.8.5 ACTIONS CONDITION                        REQUIRED ACTION                    COMPLETION TIME A.      (continued)                  A.2.3    Initiate action to            Immediately restore required DC electrical power susbsystems to OPERABLE status.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                          FREQUENCY SR 3.8.5.1        -------------------------NOTE-----------------------------
The following SRs are not required to be performed: SR 3.8.4.7 and SR 3.8.4.8.
For DC electrical power subsystems required                  In accordance to be OPERABLE the following SRs are                        with applicable applicable:                                                  SRs SR 3.8.4.1        SR 3.8.4.4    SR 3.8.4.7 SR 3.8.4.2        SR 3.8.4.5    SR 3.8.4.8.
SR 3.8.4.3        SR 3.8.4.6 DAEC                                      3.8-22                                    Amendment
 
Distribution Systems -      Shutdown 3.8.8 3.8 ELECTRICAL POWER SYSTEMS 3.8.8 Distribution Systems -            Shutdown LCO 3.8.8                The necessary portions of the AC and DC electrical power distribution subsystems shall be OPERABLE to support equipment required to be OPERABLE.
APPLICABILITY:            MODES 4 and 5.
During movement of irradiated fuel assemblies in the secondary containment.
ACTIONS
-----------------------------------------------------------NOTE-------------------------------------------------------
LCO 3.0.3 is not applicable.
CONDITION                              REQUIRED ACTION                      COMPLETION TIME A.        One or more required              A.1          Declare associated        Immediately AC or DC electrical                              supported required power distribution                              feature(s) inoperable.
subsytems inoperable.
OR Immediately A.2.1        Suspend CORE ALTERATIONS.
AND A.2.2        Suspend movement          Immediately of irradiated fuel assemblies in the secondary containment.
A.2.3        Initiate action to        Immediately restore required AC and DC electrical power distribution subsystems to OPERABLE status.
(continued)
DAEC                                            3.8-30                                    Amendment
 
Distribution Systems -  Shutdown 3.8.8 ACTIONS (continued)
CONDITION                  REQUIRED ACTION                COMPLETION TIME A.      (continued)            A.2.4    Declare associated        Immediately required shutdown cooling subsystem(s) inoperable.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                  FREQUENCY SR 3.8.8.1        Verify correct breaker alignments and          In accordance with the indicated power availability to required AC    Surveillance and DC electrical power distribution            Frequency Control subsystems.                                    Program DAEC                                3.8-31                              Amendment
 
ATTACHMENT 4 TO NG-17-0093 Proposed Technical Specification Bases Changes (Mark-Up) 80 Pages Follow
 
ECCS Instrumentation B 3.3.5.1 BASES (continued)
APPLICABLE        The actions of the ECCS are explicitly assumed in the safety SAFETY            analyses of References 1, 2 and 3. The ECCS is initiated to ANALYSES,        preserve the integrity of the fuel cladding by limiting the post LCO, and          LOCA peak cladding temperature to less than the 10 CFR 50.46 APPLICABILITY    limits.
ECCS instrumentation satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
The OPERABILITY of the ECCS instrumentation is dependent upon the OPERABILITY of the individual instrumentation channel Functions specified in Table 3.3.5.1-1. Each Function must have a required number of OPERABLE channels, with their setpoints within the specified Allowable Values, where appropriate. The actual setpoint is calibrated consistent with applicable setpoint la footnote which        methodology assumptions. Table 3.3.5.1 -1 is modified by twe footnotes . Footnote (a) is added to clarify that the associated Functions are Fequired to be OPERABLE in MODES 4 and 5 only when their supported EGGS are required to be OPERABLE per LGO 3.5.2, EGGS Shutdown . Footnote (b), is added to show that certain ECCS instrumentation Functions also perform DG initiation.
Allowable Values are specified for each ECCS Function specified in the Table. Nominal trip setpoints are specified in the setpoint calculations. The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS. Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. Trip setpoints are those predetermined values of output at which an action should take place. The setpoints are compared to the actual process parameter (e.g., reactor vessel waterlevel), and when the measured output value of the process parameter exceeds the setpoint, the associated device (e.g., on-off sensor or bi-stable trip circuit) changes state. Analytical Limits, where established, are the limiting values of the process parameters used in safety analysis to define the margin to unacceptable consequences.
Margin is provided between the Allowable Value and the Analytical Limits to allow for process, calibration (i.e., M&TE) and some instrument uncertainties. Additional margin (continued)
DAEC                              B 3.3-105                              Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE    1.a. 2.a Reactor Vessel Water Level - Low Low Low SAFETY        (continued)
: ANALYSES, LCO, and      Reactor Vessel Water Level - Low Low Low signals are initiated APPLICABILITY from four level switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. The Reactor Vessel Water Level - Low Low Low Allowable Value is chosen to allow time for the low pressure core flooding LCO, and systems to activate and provide adequate cooling .
Four channels of Reactor Vessel Water Level - Low Low Low Function are only required to be OPERABLE when the ECCS are required to be OPERABLE to ensure that no single instrument failure can preclude ECCS initiation. Per Footnote (a) to Taelo 3.3.6.1 1, tho Roaotor Vessel Water Level Low, Low, Low, Level 1 Funstion is only required to ee OPERABLE in MODES 4 and 6 whenever tho assosiatod EGGS is required to eo OPERABLE per LCO 3.5.2. Refer to LCO 3.5.1 and LCO 3.5.2, "EGGS B Shutdmvn," for Applisaeillty Bases for the low press1:1ro EGGS s1:1esystoms; LCO 3.8.1, "AC So1:1rsos            Operating"; and LCO 3JL2 , "AC 801:1rsos 08hutdown ," for Applicaeility Bases for tho DGs.
1.b, 2.b. Drvwell Pressure -  High High pressure in the drywell could indicate a break in the Reactor Coolant Pressure Boundary (RCPB). The low pressure ECCS and associated DGs are initiated upon receipt of the Drywell Pressure - High Function in order to minimize the possibility of fuel damage. The Drywell Pressure - High Function, along with the Reactor Water Level - Low Low Low Function, is directly assumed in the analysis of the recirculation line break (Ref. 2).      y The core cooling function of the ECCS, along with the scram          II action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.
High drywell pressure signals are initiated from four pressure switches that sense drywell pressure. The Allowable Value was selected to be as low as possible and be indicative of a LOCA inside primary containment.
(continued)
DAEC                        B 3.3-107                                TSCR Q44A
 
ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE    1.c, 2.c. Reactor Steam Dome Pressure - Low (Injection SAFETY        Permissive) (continued)
: ANALYSES, LCO, and      Four channels of Reactor Steam Dome Pressure - Low Function APPLICABILITY are only required to be OPERABLE when the ECCS is required to be OPERABLE to ensure that no single instrument failure can preclude ECCS initiation. Refer to LCO 3.5.1 and LCO 3.5.2 for Applicability Bases for the low pressure ECCS subsystems.
1.d, 2.f. Core Spray and Low Pressure Coolant Injection Pump Discharge Flow- Low (Bypass)
The minimum flow instruments are provided to protect the associated low pressure ECCS pump(s) from overheating when the pump is operating and the associated injection valve is not fully open. The minimum flow line valves (normally open for the CS System and normally closed for the LPCI System) receive an open signal when low flow is sensed, and automatically close when the flow rate is adequate to protect the associated pump.
The LPCI and CS Pump Discharge Flow - Low Functions are assumed to be OPERABLE and capable of closing the minimum flow valves to ensure that the low pressure ECCS flow rates assumed during the transients and accidents analyzed in References 1, 2, and 3 are met. The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.
One flow switch per CS pump and one differential pressure switch for the two RHR pumps in each division are used to detect the associated subsystems' flow rates. The logic is arranged such that each differential pressure switch or flow switch causes its associated minimum flow valve to receive an open signal. The logic will close the minimum flow valve once the closure setpoint is exceeded. The LPCI minimum flow valves are time delayed such that the valves will not open for 10 seconds after the switches detect low flow. The time delay is provided by design to limit reactor vessel inventory loss during the startup of the RHR shutdown cooling mode although, typically, the minimum flow valves are prevented from opening when operating in the shutdown cooling mode. The Pump Discharge Flow - Low Allowable Values are high enough to ensure that the pump flow rate is sufficient to protect the pump, yet low enough to ensure (continued)
DAEC                          B 3.3-109                          Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE    1.d, 2.f. Core Spray and Low Pressure Coolant lniection Pump SAFETY        Discharge Flow-Low (Bypass) (continued)
: ANALYSES, LCO, and      that the closure of the minimum flow valve is initiated to allow the APPLICABILITY assumed flow into the core. Each channel of Pump Discharge Flow - Low Function (two CS channels, one per pump and two LPCI channels, one per loop) is only required to be OPERABLE when the associated ECCS is required to be OPERABLE to ensure that no single instrument failure can preclude the ECCS function.* Refer to LCO 3.5.1 and LCO 3.5.2 for Applicability          t t
Bases for the low pressure ECCS subsystems.
* Per footnote (e) to Function 1d in Table 3.3.5.1 1, the CS minimum flow path instrumentation is not required to be OPER/\gLE in MODES 4 and 5 during RFO 23.
2.d. Reactor Vessel Shroud Level - Low The Reactor Vessel Shroud Level-Low Function is provided as a permissive to allow the RH.R System to be manually aligned from the LPCI mode to the suppression pool cooling/spray or drywell spray modes with a LPCI initiation signal still present. This function ensures: 1) that the permissive is removed prior to reaching two thirds core height when vessel level ls decreasing, and 2) that the permissive is not restored until two thirds core height is reached when vessel level is increasing. This ensures that LPCI is available to prevent or minimize fuel damage. This function may be overridden during accident conditions as allowed by plant procedures to allow containment cooling/spray regardless of the level present in the shroud.
Reactor Vessel Shroud Level - Low signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. The Reactor Vessel Shroud Level - Low Allowable Value is chosen to allow the low pressure core flooding systems to activate and provide adequate cooling before allowing a manual transfer.
Four channels of the Reactor Vessel Shroud Level - Low Function are only required to be OPERABLE in MODES 1, 2, and 3. In MODES 4 and 5, the specified initiation time of the LPCI subsystems is not assumed, and other administrative controls are adequate to control the valves that this Function Isolates (since the containment cooling mode of RHR is not required to be OPERABLE in MODES 4 and 5 and is normally not used).
(continued)
DAEC                          B3.3-110                                    TSCR 135
 
ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE    1.e, 2.e Core Spray Pump Startup - Time Delay Relay and Low SAFETY        Pressure Coolant Injection Pump Start - Time Delay Relay
: ANALYSES, LCO, and      The purpose of these time delay relays is to stagger the start of APPLICABILITY the CS pumps and LPCI pumps that are in each of Divisions 1 and 2, thus limiting the starting transients on the 4.16 kV emergency buses. This Function is only necessary when power is being supplied from the standby power sources (DG). However, since the time delay does not degrade ECCS operation, it remains in the pump start logic at all times. The CS Pump and LPCI Pump Start - Time Delay Relays are assumed to be OPERABLE in the accident and transient analyses requiring ECCS initiation. That is, the analyses assume that the pumps will initiate when required and excess loading will not cause failure of the standby power sources.
There are two CS Pump Start - Time Delay Relays and four LPCI Pump Start - Time Delay Relays, one in each of the CS and RHR pump start logic circuits. While each time delay relay is dedicated to a single pump start logic, a single failure of a CS Pump Start -
Time Delay Relay or of a LPCI Pump Start - Time Delay Relay could result in the failure of the three low pressure ECCS pumps, powered from the same emergency bus if the emergency bus is being powered by its associated DG, to perform their intended function within the assumed time (e.g., as in the case where two or more ECCS pumps on one emergency bus start simultaneously due to an inoperable time delay relay which, In turn cause the associated DG output breaker to trip open due to undervoltage conditions). This still leaves three of the six low pressure ECCS pumps OPERABLE; thus, the single failure criterion is met (i.e.,
loss of one instrument does not preclude ECCS initiation). The Allowable Value for the CS Pump Start-Time Delay Relay and each LPCI Pump          Start - Time Delay Relay is chosen to be long enough so that most of the starting transient of one pump is complete before starting another pump on the same 4.16 kV emergency bus and short enough so that ECCS operation is not degraded.
Each CS Pump Start - Time Delay Relay and each LPCI Pump Start - Time Delay Relay Function is required to be OPERABLE only when the associated CS or LPCI System is required to be OPERABLE. Refer to LCO 3.5.1 and LGO d.5.2 for Applicability Bases for the CS and LPCI Systems.
(continued)
DAEC                          B 3.3-111                            Amendment 22d
 
ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE    1.f 2.k 4.16 kV Emergency Bus Sequential Loading Relay SAFETY ANALYSES,    An undervoltage condition on an emergency bus indicates that LCO, and      sufficient power (from either the offsite or onsite sources) is not APPLICABILITY available to allow starting of the low pressure ECCS pumps.
(continued) Therefore, if this condition exists, the start permissive signal is withheld from the circuits that start both the Core Spray (CS) and Low Pressure Coolant Injection (LPCI) pumps during accident conditions , and the CS and LPCI pumps powered from the respective emergency bus are prevented from starting. This ensures that the low pressure ECCS pumps are not started during accident conditions unless adequate power is available.
Each emergency bus is monitored by a single relay, which inputs into a one-out-of-two once logic for each division. Each logic channel supports one CS and two LPCI pumps. An instrument channel consists of the common bus monitoring relay and the associated relay contacts for each ECCS pump.
The 4.16 kV Emergency Bus Sequential Loading Relay Allowable Values are low enough to prevent low pressure ECCS pump starting unless adequate power is available, but high enough so that low pressure ECCS pump starting is not unnecessarily prohibited or delayed and is within the maximum adjustable range of the relay.
To ensure that no single failure can prevent successful operation of the combined low pressure ECCS, two channels of the 4.16 kV Emergency Bus Sequential Loading Relay Function are required to be OPERABLE whenever the LPCI System is required to be OPERABLE (i.e., MODES 1, 2, and 3), and one channel is reqblired to be OPERABLE whenever the associated LPCI pblmp(s) is reqblired to be OPERABLE by LCO 3.5.2, "EGGS Shbltdown ." One channel of 4.16 kV Emergency Bbls Seqblential Loading Relay Fblnction is reqblired to be OPERABLE whenever the associated CS Sblbsystem (i.e ., pblmp) is reqblired to be OPERABLE. To ensblre this Fblnction is available when reqblired ,
the 4.16 l<V emergency Bbls Seqblential Loading Relay is roqblirod to be OPERABLE in MODES 1, 2, and 3, and when the associated lmv pressblre EGGS is reqblired to be OPERABLE by LGO 3.5.2, "EGGS Shbltdown ." Refer to LCO 3.5.1 and LCO
              ~for Applicability Bases for the CS and LPCI Systems.
(continued)
DAEC                          B3.3-112                              Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES ACTIONS B.1. B.2 and B.3 (continued)
For Required Action B.2, automatic initiation capability is lost if certain combinations of Function 3.a or Function 3.b channels are inoperable and untripped. In this situation (loss of automatic initiation capability), the 24 hour allowance of Required Action B.3 is not appropriate and the feature(s) associated with the inoperable, untripped channels must be declared inoperable within 1 hour. As noted (~Jots 1 to RSEfblirsd Action g _1), RSEfblirsd Action g _1 is only applicable in MODES 1, 2, and a. In MODES 4 and 5, the specific initiation time of the low prsssblrs EGGS is not assblmsd and the probability of a LOGA is lower. Thbls, a total loss of initiation capability f-Or 24 hoblrs (as allowed by RSEf blirsd Aotion g _a) is allowed during MODES 4 and 5. There is no similar Nots provided f-Or RSEfblirsd Action g_2 sines HPGI instFblmsntation is not rSEf blirsd in MODES 4 and 5; thbls, a Nots is not necessary.
Notes are ffise    pr~ote          2- to Required Action B.1 and the Note to Required Action B.2) to delineate which Required Action is applicable for each Function that requires entry into Condition B if an associated channel is inoperable. This ensures that the proper loss of Initiation capability check Is performed. Required Action B.1 (the Required Action for certain Inoperable channels in the low pressure ECCS subsystems) is not applicable to Function 2.d, since this Function provides backup to administrative controls ensuring that operators do not divert LPCI flow from injecting into the core when needed. Thus, a total loss of Function 2.d capability for 24 hours is allowed, since the LPCI System remains capable of performing its intended function.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowable out of service time "clock." For Required Action B.1, the Completion Time only begins upon discovery that a redundant feature in two or more low pressure ECCS subsystems (i.e., both CS subsystems or either CS subsystem in combination with the LPCI subsystem) cannot automatically initiate their supported features due to inoperable, untripped channels within the same Function as described in the paragraph above.
(continued)
DAEC                      B 3.3-126                            Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES ACTIONS C.1. C.2 and C.3 (continued)
(d) two or more Function 2.i channels for the same recirculation pump are inoperable in both trip systems, (e) two Function 2.j channels are inoperable in both trip systems, or (f) two or more Function 1.e or 2.e channels are inoperable in different divisions.
In these situations (loss of redundant automatic initiation capability), the 24 hour allowance of Required Action C.3 is not appropriate and the feature(s) associated with the inoperable channels must be declared inoperable within 1 hour. Since each inoperable channel would have Required Action C.1 or C.2, as appropriate, applied separately (refer to ACTIONS Note), each inoperable channel would only require the affected portion of the associated system to be declared inoperable. However, since channels for either both divisions of LPCI loop select logic or for two or more low pressure ECCS subsystems are inoperable (e.g.,
both CS subsystems or either CS subsystem in combination with the LPCI subsystem), and the Completion Times started concurrently for the channels in both subsystems, this results in the affected portions in both subsystems being concurrently declared inoperable. For Functions 1.c, 1.e, and 2.e, the affected portions are the associated low pressure ECCS pumps. For Functions 2.g, 2.h, 2.i, and 2.j, the affected portion is the LPCI subsystem. As noted (~Jote 1), ReEtuired Actions G.1 and G.2 are only applioable in MODES 1, 2, and      a. In MODES 4 and 5, the specific initiation time of the EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of automatic initiation capability for 24 hours (as allowed by ReEtuired Action G.3) is allowed during MODES 4 and 5.          ~
Note ~ to Required Action C.1 states that Require~~~~n C.1 is only applicable for Functions 1.c, 2.c, 1.e, and 2.e. Note ~ to Required Action C.2 states that Required Action C.2 is only applicable for Functions 2.g, 2.h, 2.i, and 2.j. Required Actions C.1 and C.2 are not applicable to Function 3.c (which also requires entry into this Condition if a channel in this Function is inoperable), since the loss of one channel results in a loss of the Function (two-out-of-two logic). This loss was considered during the development of Reference 5 and considered acceptable for the 24 hours allowed by Required Action C.3.
(continued)
DAEC                    B 3.3-128                            Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES ACTIONS      E.1 and E.2 (continued)
Required Action E.1 is intended to ensure that appropriate actions are taken if multiple, inoperable channels within the Core Spray and Low Pressure Coolant Injection Pump Discharge Flow -
Low Bypass Functions result in redundant automatic initiation capability being lost for the feature(s). For Required Action E.1, the features would be those that are initiated by Functions 1.d and 2.f (e.g., low pressure ECCS). Redundant automatic initiation capability is lost if either the automatic opening or closing function for two or more low pressure ECCS minimum flow valves is inoperable. Since each of the four minimum flow valves is initiated by a corresponding instrument channel, redundant automatic initiation capability is lost if any two of the four Function 1.d and 2.f channels are inoperable. Since each inoperable channel would have Required Action E.1 applied separately (refer to ACTIONS Note), each inoperable channel would only require the affected low pressure ECCS pump(s) to be declared inoperable. However, since channels for two or more minimum flow valves in the low pressure ECCS subsystems are inoperable, and the Completion Times started concurrently for the channels of the low pressure ECCS minimum flow valves, this results in the affected low pressure ECCS pump(s) being concurrently declared inoperable.
In this situation (loss of redundant automatic initiation capability),
the 7 day allowance of Required Action E.2 is not appropriate and the system or subsystem associated with each inoperable channel must be declared inoperable within 1 hour. As noted (Note 1 to Required Action E.1 ), Required ,l\ction E.1 is only applicable in MODES 1, 2, and 3. In MODES 4 and 5, the specific initiation time of the EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of initiation capability for 7 days (as allowed by Required Action E.2) Is allo ned during MODES 4 1
and 5. A Note is also provided ote ~ to Required Action E.1) to delineate that Required Action        is only applicable to low pressure ECCS Functions. Req *red Action E.1 is not applicable to HPCI Function 3.f since the los of one channel results in a loss of the Function (one-out-of-one log c). This loss was considered during the development of Referen 5 and considered acceptable for the 7 days allowed b Required Action E.2.
(continued)
DAEC                          B 3.3-131                              Amendment 223
 
ECCS Instrumentation B 3.3.5.1 BASES ACTIONS                E.1 (continued)
With a Function 1.f (2.k) channel inoperable, the 4.16 kV Emergency Bus Sequential Loading Relay is not cable of providing a start permissive signal for the low pressure ECCS pumps in the affected division , and the associated low pressure ECCS are not capable of performing their intended functions.
Placing a channel in the tripped condition makes the associated ECCS pump(s) inoperable, since the pump(s) is prevented from automatically starting . In fact, tripping the bus power monitor relay will cause the associated DG to start, as it is common to the bus undervoltage logic. Consequently, one hour is provided to restore OPERABILITY of the channel. Otherwise, the affected
!subsystems    ~            low pressure ECCS (e .g., tho CS subsystem in tho attested
* r----~.::,,,. division, tho LPCI System if either division is affosted in Modes 1, 2 or 3, and tho LPCI pump(s) in tho a#ostod division for Modes 4 and 5) are declared inoperable immediately. This requires entry into LCO 3.5.1 or LCO 3.5.2, which provide~      appropriate actions for inoperable low pressure ECCS Systems a subsystems.
G.1 and G.2                                        s Required Action G.1 is intended to ensure that appropriate actions are taken If multiple, Inoperable, untripped channels within similar ADS trip logic A and B Functions result in redundant automatic initiation capability being lost for the ADS . Redundant automatic initiation capability is lost if either (a) one Function 4.a channel and one Function 5.a channel are inoperable and untripped, or (b) one Function 4.c channel and one Function 5.c channel are inoperable and untripped .
In this situation (loss of automatic initiation capability), the 96 hour or 8 day allowance, as applicable, of Required Action G.2 is not appropriate and all ADS valves must be declared inoperable within 1 hour after discovery of loss of ADS initiation capability.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilitles. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowable out of service time "clock."
(continued)
DAEC                                  B 3.3-133                              Amendment ~
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 B 3.3 INSTRUMENTATION B 3.3.5.2 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation BASES BACKGROUND          The RPV contains penetrations below the top of the active fuel (T AF) that have the potential to drain the reactor coolant inventory to below the T AF.
If the water level should drop below the TAF, the ability to remove decay heat is reduced, which could lead to elevated cladding temperatures and clad perforation. Safety Limit 2.1.1.3 requires the RPV vvater level to be above the top of the active irradiated fuel at all times to prevent such elevated cladding temperatures.
Technical Specifications are required by 10 CFR 50.36 to include limiting safety system settings (LSSS) for variables that have significant safety functions. LSSS are defined by the regulation as "Where a LSSS is specified for a variable on which a safety limit has been placed, the setting must be chosen so that automatic protective actions will correct the abnormal situation before a Safety Limit (SL) is exceeded." The Analytical Limit is the limit of the process variable at which a safety action is initiated to ensure that a SL is not exceeded. Any automatic protection action that occurs on reaching the Analytical Limit therefore ensures that the SL is not exceeded. Ho\ll/9ver, in practice, the actual settings for automatic protection channels must be chosen to be more conservative than the Analytical Limit to account for instrument loop uncertainties related to the setting at which the automatic protective action would actually occur. The actual settings for the automatic isolation channels are the same as those established for the same functions in MODES 1, 2, and 3 in LCO 3.3.5.1, "Emergency Core Cooling System (ECCS)
Instrumentation," or LCO 3.3.6.1, "Primary Containment Isolation instrumentation".
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses.
RPV vvater inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur. Under the definition of DRAIN TIME, some penetration flow paths may be excluded from the DRAIN TIME calculation if they will be isolated by valves that will close automatically without offsite po\ll/9r prior to the RPV vvater level being equal to the T AF when actuated by RPV vvater level isolation instrumentation.
DAEC                                  B 3.3.5.2A-1
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES BACKGROUND (continued)
The purpose of the RPVWater Inventory Control Instrumentation is to support the requirements of LCO 3.5.2, "Reactor Pressure Vessel (RPV)
Water Inventory Control," and the definition of DRAIN TIME. There are functions that are required for manual initiation or operation of the ECCS injection/spray subsystem required to be OPERABLE by LCO 3.5.2 and other functions that support automatic isolation of Residual Heat Removal subsystem and Reactor Water Cleanup system penetration flow path(s) on low RPV water level.
The RPV Water Inventory Control Instrumentation supports operation of core spray (CS) and low pressure coolant injection (LPCI). The equipment involved with each of these systems is described in the Bases for LCO 3.5.2.
APPLICABLE        With the unit in MODE 4 or 5, RPV water inventory control is not required SAFETY            to mitigate any events or accidents evaluated in the safety analyses. RPV ANALYSES, LCO,    water Inventory control is required in MODES 4 and 5 to protect and APPLICABILITY Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure, reduced piping stresses, and ductile piping systems. Instead, an event is postulated in which a single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g.,
seismic event, loss of normal power, single human error). It is assumed, based on engineering judgment, that while in MODES 4 and 5, one low pressure ECCS injection/spray subsystem can be manually initiated to maintain adequate reactor vessel water level.
As discussed in References 1, 2, 3, 4, and 5, operating experience has shown RPV water inventory to be significant to public health and safety.
Therefore, RPV Water Inventory Control satisfies Criterion 4 of 10 CFR 50.36( c)(2)(ii).
Permissive and interlock setpoints are generally considered as nominal values without regard to measurement accuracy.
DAEC                                B 3.3.5.2A-2
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
Core Spray and Low Pressure Coolant Injection Systems 1.a. 2.a. Reactor Steam Dome Pressure - Low(lnjection Permissive)
Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. This function ensures that, prior to opening the injection valves of the low pressure ECCS subsystems, the reactor pressure has fallen to a value below these subsystems' maximum design pressure. While it is assured during MODES 4 and 5 that the reactor steam dome pressure will be below the ECCS maximum design pressure, the Reactor Steam Dome Pressure - Low signals are assumed to be OPERABLE and capable of permitting initiation of the ECCS.
The Reactor Steam Dome Pressure - Low signals are initiated from four pressure switches that sense the reactor dome pressure. The pressure switches are connected to relays whose contacts are arranged In a one-out-of-two taken twice logic.
The Allowable Value is low enough to prevent overpressuring the equipment in the low pressure ECCS.
The four channels of Reactor Steam Dome Pressure - Low Function are required to be OPERABLE in MODES 4 and 5.
1.b. 2.b. Core Spray and Low Pressure Coolant Injection Pump Discharae Flow- Low (Bypass)
The minimum flow instruments are provided to protect the associated low pressure ECCS pump from overheating when the pump is operating and the associated injection valve is not fully open. The minimum flow line valve is opened when low flow is sensed, and the valve is automatically closed when the flow rate is adequate to protect the pump.
One flow transmitter for each Core Spray subsystem and each LPCI subsystem is used to detect the associated subsystems' flow rates. The logic is arranged such that each transmitter causes its associated minimum flow valve to open. The logic will close the minimum flow valve once the closure setpoint is exceeded. The LPCI minimum flow valves are time delayed such that the valves will not open for 10 seconds after the switches detect low flow. The time delay is DAEC                            B 3.3.5.2A-3
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued) provided to limit reactor vessel inventory loss during the startup of the Residual Heat Removal (RHR) shutdown cooling mode.
The Pump Discharge Flow- Low Allowable Values are high enough to ensure that the pump flow rate is sufficient to protect the pump, yet low enough to ensure that the closure of the minimum flow valve is initiated to allow full flow into the core.
One channel of the Pump Discharge Flow- Low Function is required to be OPERABLE in MODES 4 and 5 when the associated Core Spray or LPCI pump is required to be OPERABLE by LCO 3.5.2 to ensure the subsystem is capable of injecting into the Reactor Pressure Vessel when manually initiated.
RHR System Isolation 3.a - Reactor Vessel Water Level - Low The definition of Drain Time allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite po\Aler prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation Instrumentation. The ReactorVessel Water Level- Low Function associated with RHR System isolation may be credited for automatic isolation of penetration flow paths associated with the RHR System.
Reactor Vessel Water Level - Low signals are initiated from four level indicating switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level - Low Function are available, only two channels (all in the same trip system) are required to be OPERABLE.
DAEC                              B 3.3.5.2A-4
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
The Reactor Vessel Water Level - Low Allowable Value was chosen to be the same as the Primary Containment Isolation Instrumentation Reactor Vessel Water Level - Low Allowable Value (LCO 3.3.6.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level- Low Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
This Function isolates the Group 4 valves.
Reactor Water Cleanup (RWCU) System Isolation 4.a - Reactor Vessel Water level - Low Low The definition of Drain Time allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite povver prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation. The ReactorVessel Water Level- Low Low Function associated with RWCU System isolation may be credited for automatic isolation of penetration flow paths associated with the RWCU System.
Reactor Vessel Water Level - Low Low signals are initiated from four level Indicating switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) In the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level - Low Function are available, only two channels (all in the same trip system) are required to be OPERABLE.
The Reactor Vessel Water Level - Low Low Allowable Value was chosen to be the same as the ECCS Reactor Vessel Water Level - Low_Low Allowable Value (LCO 3.3.5.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low Low Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
This Function isolates the Group 5 valves.
DAEC                              B 3.3.5.2A-5
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES ACTIONS A Note has been provided to modify the ACTIONS related to RPV Water Inventory Control instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable RPV Water Inventory Control instrumentation channels provide appropriate compensatory measures for separate inoperable Condition entry for each inoperable RPV Water Inventory Control instrumentation channel.
Required Action A.1 directs entry into the appropriate Condition referenced in Table 3.3.5.2-1. The applicable Condition referenced in the Table is Function dependent. Each time a channel Is discovered inoperable, Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
B.1 and B.2 RHR System Isolation, Reactor Vessel Water Level- Low and Reactor Water Cleanup System, Reactor Vessel Water Level - Low Low functions are applicable when automatic isolation of the associated penetration flow path is credited in calculating Drain Time. If the instrumentation is inoperable, Required Action B.1 directs an immediate declaration that the associated penetration flowpath(s) are incapable of automatic isolation.
Required Action B.2 directs calculation of DRAIN TIME. The calculation cannot credit automatic isolation of the affected penetration flow paths.
DAEC                      B 3.3.5.2A-6
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES ACTIONS (continued)
C.1 Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. If the permissive is inoperable, manual initiation of ECCS is prohibited. Therefore, the permissive must be placed in the trip condition
                  \Alithin 1 hour. With the permissive in the trip condition, manual initiation may be performed.
The Completion Time of 1 hour is intended to allow the operator time to evaluate any discovered inoperabilities and to place the channel in trip.
If a Core Spray or Low Pressure Coolant Injection Pump Discharge Flow-Low bypass function is inoperable, there is a risk that the associated low pressure ECCS pump could overheat when the pump ls operating and the associated injection valve ls not fully open. In this condition, the operator can take manual control of the pump and the injection valve to ensure the pump does not overheat.
The 24 hour Completion Time was chosen to allow time for the operator to evaluate and repair any discovered inoperabilities. The Completion Time is appropriate given the ability to manually start the ECCS pumps and open the injection valves and to manually ensure the pump does not overheat.
With the Required Action and associated Completion Time of Condition C or D not met, the associated low pressure ECCS injection/spray subsystem may be incapable of performing the intended function, and must be declared inoperable immediately.
DAEC                                B 3.3.5.2A-7
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES SURVEILLANCE  As noted in the beginning of the SRs, the SRs for each RPVWater
,REQUIREMENTS Inventory Control instrument Function are found in the SRs column of Table 3.3.5.2-1.
SR 3.3.5.2.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a similar parameter on other channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK guarantees that undetected outright channel failure is limited; thus, it is key to verifying the instrumentation continues to operate properly betvveen each CHANNEL FUNCTIONAL TEST.
Agreement criteria are determined by the plant staff, based on a combination of the channel instrument uncertainties, including indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The CHANNEL CHECK supplements less formal, but more frequen~
checks of channels during normal operational use of the displays associated with the channels required by the LCO.
DAEC                            B 3.3.5.2A-8
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.3.5.2.2 A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function. A successful test of the required contact(s) of a channel relay may be performed by the verification of the change of state of a single contact of the relay. This clarifies what is an acceptable CHANNEL FUNCTIONAL TEST of a relay. This is acceptable because all of the other required contacts of the relay are verified by other Technical Specifications and non-Technical Specifications tests.
Any setpoint adjustment shall be consistent with the assumptions of the current plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
sR a.a.e.2.a Tlie LOGIC 6&#xa5;STEM FUNCTIO~~L TEST demonstretes tlie OPERABILITY of tlie required initiatien legic f.or a speeifie ohannel. Tho system functional testing perfoAlled in LGO 3.5.2 overlaps this 8u1 veilla1 ice to eo11iplete testing of tlie assumed safetyfunetien.
Hie Sur'o*eillance Frequeney is eontrolled under the Survoillan~
Frequency Control Program.
DAEC                                B 3.3.5.2A-9
 
RPV Water Inventory Control Instrumentation B 3.3.5.2 BASES SURVEILLANCE REQUIREMENTS (continued)
REFERENCES      1. Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup,"
November 1984.
: 2. Information Notice 86-7 4, "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves," August 1986.
: 3. Generic Letter 92-04, "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10 CFR 50.54(F), "August 1992.
: 4. NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs," May 1993.
: 5. Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1," July 1994.
DAEC                          B 3.3.5.2A-10
 
--=y RCIC System Instrumentation B 3.3.5 .~
B 3.3 INSTRUMENTATION
                                                                                          ~
B 3.3.5.~ Reactor Core Isolation Cooling (RCIC) System Instrumentation BASES ~
BACKGROUND          The purpose of the RCIC System instrumentation is to initiate actions to ensure adequate core cooling when the reactor vessel is isolated from its primary heat sink (the main condenser) and normal coolant makeup flow from the Reactor Feedwater System is unavailable, such that initiation of the low pressure Emergency Core Cooling Systems (ECCS) pumps does not occur. A more complete discussion of RCIC System operation is provided in the Bases of LCO 3.5.3, "RCIC System."
The RCIC System may be initiated by either automatic or manual means, although manual initiation requires manipulation of individual component control switches. Automatic initiation occurs for conditions of reactor vessel low low water level. The variable is monitored by four level switches that are connected to relays whose contacts are arranged in a one-out-of-two taken twice logic arrangement. Once initiated, the RCIC logic seals in and can be reset by the operator only when the reactor vessel water level signals have cleared.
The RCIC test return valve is closed on a RCIC initiation signal to allow full system flow to the Reactor Pressure Vessel (RPV).
However, this design feature is not assumed in any transient analyses. Transient analyses are performed assuming the RCIC System is in the standby readiness condition when the transient occurs.
The RCIC System also monitors the water levels in the Condensate Storage Tank (CST) since this is the preferred source of water for RCIC operation. Upon receipt of a RCIC initiation signal, the CST suction valve is automatically signaled to open (it is normally in the open position) unless the pump suction from the suppression pool valves is open. If the water level in the CST falls below a preselected level, first the suppression pool suction valves automatically open, and then the CST suction valve automatically closes. Two level switches are used to detect low water level in the CST. Either switch can cause the suppression pool suction valves to open and the CST suction valve to close (i.e., one-out-of-two once logic).
(continued)
DAEC                                B 3.3-140                            Amendment ~
 
RCIC System Instrumentation B 3.3.5.~
BASES
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ill BACKGROUND    To prevent losing suction to the pump, the suction valves are (continued) interlocked so that one suction path must be open before the other automatically closes.
The RCIC System provides makeup water to the reactor until the reactor vessel water level reaches the RPV high water level trip (two-out-of-two once logic), at which time the RCIC steam supply valve closes (the injection valve also closes due to the closure of the steam supply valve). The RCIC System restarts if vessel level again drops to the low low level initiation point.
APPLICABLE    The function of the RCIC System, to provide makeup coolant to SAFETY
: ANALYSES, LCO, and APPLICABILITY the reactor, is used to respond to transient events. The RCIC System is not an ECCS System, although the RCIC System Operation is credited during Loss of Feedwater events. Based on its contribution to the reduction of overall plant risk, however, the system, and therefore its instrumentation meets Criterion 4 of 10 t
CFR 50.36(c)(2)(ii). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
3 The OPERABILITY of the RCIC System instrumentation is dependent upon the OPERABILITY of the individual instrumentation channel Functions specified in Table 3.3.5.~ 1.
Each Function must have a required number of OPERABLE channels with their setpoints within the specified Allowable Values. The actual setpoint is calibrated consistent with applicable setpoint methodology assumptions.
Allowable Values are specified for each RCIC System instrumentation Function specified in the Table. Nominal trip setpoints are specified in the setpoint calculations. The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS.
Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. Trip Setpoints are those predetermined values of output at which an action should take place.
(continued)
DAEC                          B 3.3-141                                    TSCR 150
 
RCIC System Instrumentation ~
B 3.3 . 5 .~
BASES APPLICABLE    The setpoints are compared to the actual process parameter (e.g.,
SAFETY        reactor vessel water level), and when the measured output value ANALYSES,    of the process parameter exceeds the setpoint, the associated LCO, and      device (e.g., on-off sensor, bi-stable trip circuit, or trip unit)
APPLICABILITY changes state. Margin is provided to allow for process, calibration (continued)  (i.e., M&TE) and some instrument uncertainties (e.g., drift).
Allowable Values derived in this manner provide adequate protection because instrumentation uncertainties, process effects, calibration tolerances, instrument drift, and severe environment errors (for channels that must function in harsh environments as defined by 10 CFR 50.49) are accounted for.
The individual Functions are required to be OPERABLE in MODE 1, and in MODES 2 and 3 with reactor steam dome pressure > 150 psig since this is when RCIC is required to be OPERABLE. (Refer to LCO 3.5.3 for Applicability Bases for the RCIC System .)
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
: 1. Reactor Vessel Water Level -      Low Low Low RPV water level indicates that normal feedwater flow is insufficient to maintain reactor vessel water level and that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, the RCIC System is initiated at Reactor Vessel Water Level - Low Low to assist in maintaining water level above the top of the active fuel.
Reactor Vessel Water Level - Low Low signals are initiated from four level switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level - Low Low Allowable Value is set high enough such that for complete loss of feedwater flow, the RCIC System flow with the High Pressure Coolant Injection assumed to fail will be sufficient to maintain adequate core cooling. However, the prevention of the (continued)
DAEC                        B 3.3-142                                      TSCR 044
 
RCIC System    Instrumentation~
B 3.3.5.~
BASES APPLICABLE    1. Reactor Vessel Water Level -    Low Low (continued)
SAFETY ANALYSES,    initiation of low pressure ECCS at Reactor Vessel Water Level -
LCO, and      Low Low Low is not assured.
APPLICABILITY Four channels of Reactor Vessel Water Level - Low Low Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
: 2. Reactor Vessel Water Level -    High High RPV water level indicates that sufficient cooling water inventory exists in the reactor vessel such that there is no danger to the fuel. Therefore, the Reactor Vessel Water Level - High signal is used to close the RCIC steam supply valve to prevent overflow into the Main Steam Lines (MSLs). (The injection valve also closes due to the closure of the steam supply valve.)
Reactor Vessel Water Level - High signals for RCIC are initiated from two level switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level - High Allowable Value is high enough to preclude isolating the injection valve of the RCIC during normal operation, yet low enough to trip the RCIC System prior to water overflowing into the MSLs.
Two channels of Reactor Vessel Water Level - High Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
: 3. Condensate Storage Tank Level -      Low Low level in the CST indicates the unavailability of an adequate supply of makeup water from this preferred source. Normally, the suction valve between the RCIC pump and the CST is open and, upon receiving a RCIC initiation signal, (continued)
DAEC                          B 3.3-143                                TSCR 044
 
RCIC System Instrumentation ~
B3.3.5. ~
BASES APPLICABLE    3. Condensate Storage Tank Level -        Low (continued)
SAFETY ANALYSES,    water for RCIC injection would be taken from the CST. However, if LCO, and      the water level in the CST falls below a preselected level, first the APPLICABILITY suppression pool suction valves automatically open, and then the CST suction valve automatically closes. This ensures that an adequate supply of makeup water is available to the RCIC pump.
To prevent losing suction to the pump, the suction valves are interlocked so that the suppression pool suction valves must be open before the CST suction valve automatically closes.
Two level switches are used to detect low water level in the CSTs.
The Condensate Storage Tank Level - Low Function Allowable Value is set high enough to ensure adequate pump suction head while water is being taken from the CST.
Two channels of Condensate Storage Tank Level - Low Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC swap to suppression pool source. Refer to LCO 3.5.3 for RCIC Applicability Bases.
ACTIONS      A Note has been provided to modify the ACTIONS related to RCIC System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition.
Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable RCIC System instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, the Note has been provided to allow separate Condition entry for each inoperable RCIC System instrumentation channel.
(continued)
DAEC                          B 3.3-144                            Amendment 22d
 
RCIC System Instrumentation B 3.3.5. ~
BASES ACTIONS      A.1 (continued)
Required Action A.1 directs          into the appropriate Condition referenced in Table 3.3.5.2-      The applicable Condition referenced in the Table is Function dependent. Each time a channel is discovered to be inoperable, Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
B.1 and B.2 Required Action B.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in a complete loss of automatic initiation capability for the RCIC System. In this case, automatic initiation capability is lost if certain combinations of two Function 1 channels are inoperable and untripped . In this situation (loss of automatic initiation capability), the 24 hour allowance of Required Action B.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour after discovery of loss of RCIC initiation capability.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowable out of service time "clock".
For Required Action B.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically initiated due to the required combination of two inoperable, untripped Reactor Vessel Water Level - Low Low channels. The 1 hour Completion Time from discovery of loss of initiation capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
Because of the redundancy of sensors available to provide initiation signals and the fact that the RCIC System is not assumed in any accident analysis, an allowable out of service time of 24 hours has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status.
(continued)
DAEC                          B 3.3-145                            Amendment 22a
 
RCIC System Instrumentation B 3.3.5.~
BASES                                                                            ~
ACTIONS B.1 and B.2 (continued)
If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed in the tripped condition per Required Action B.2. Placing the inoperable channel in trip would conservatively compensate for the inoperability, restore capability to accommodate a single failure, and allow operation to continue. Alternately, if it is not desired to place the channel in trip (e.g., as in the case where placing the inoperable channel in trip would result in an initiation),
Condition E must be entered and its Required Action taken .
A risk based analysis was performed and determined that an allowable out of service time of 24 hours (Ref. 1) is acceptable to permit restoration of any inoperable channel to OPERABLE status (Required Action C.1 ). A Required Action (similar to Required Action B.1) limiting the allowable out of service time, if a loss of automatic RCIC initiation capability exists, is not required. This Condition applies to the Reactor Vessel Water Level - High Function whose logic is arranged such that any inoperable channel will result in a loss of automatic RCIC shutdown on high level capability. As stated above, this loss of automatic RCIC shutdown capability was analyzed and determined to be acceptable.
D.1. D.2.1. and D.2.2 Required Action D.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in automatic suction transfer capability being lost. The automatic suction transfer capability is lost if two Function 3 channels are inoperable and untripped. In this situation (loss of automatic suction transfer), the 24 hour allowance of Required Actions D.2.1 and D.2.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour from discovery of loss of RCIC suction transfer capability. As noted, Required Action D.1 is only applicable if the RCIC pump suction is not aligned to the suppression pool since, if aligned, the Function is already performed.
(continued)
DAEC                    B 3.3-146                            Amendment 223
 
RCIC System Instrumentation 83.3.5.~~
BASES ACTIONS D.1. D.2.1. and D.2.2 (continued)
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowable out of service time "clock." For Required Action D.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically aligned to the suppression pool due to two inoperable, untripped channels in the same Function . The 1 hour Completion Time from discovery of loss of suction transfer capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
Because of the redundancy of sensors available to provide suction transfer signals and the fact that the RCIC System is not assumed in any accident analysis, an allowable out of service time of 24 hours has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed In the tripped condition per Required Action D.2.1, which performs the intended function of the channel (shifting the suction source to the suppression pool).
Alternatively, Required Action D.2.2 allows the manual alignment of the RCIC suction to the suppression pool, which also performs the Intended function. If Required Action D.2.1 or D.2.2 is performed, measures should be taken to ensure that the RCIC System piping remains filled with water. If it is not desired to perform Required Actions D.2.1 and D.2.2 (e.g., as in the case where shifting the suction source could drain down the RCIC discharge piping), Condition E must be entered and its Required Action taken.
With any Required Action and associated Completion Time not met, the RCIC System may be incapable of performing the intended function, and the RCIC System must be declared inoperable immediately.
(continued)
DAEC                    B 3.3-147                            AmsnElmsnt 223
 
RCIC System Instrumentation B 3.3. .~
BASES (continued)
SURVEILLANCE      As noted in the beginning of the        , e SRs for each RCIC REQUIREMENTS      System instrumentation F        on are found in the SRs column of Table 3.3.5. ~-1 .
The S eillances are modified by a Note to indicate that when a ch nel is placed in an inoperable status solely for performance of quired Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours for Functions 2 and 3; and (b) for up to 6 hours for Function 1, provided the associated Function maintains trip capability. Upon completion of the Surveillance, or expiration of the 6 hour allowance, the channel must be returned to status or the applicable Condition entered and Required Actions taken. This Note is based on the reliability analysis (Ref. 1) assumption of the average time required to perform channel surveillance. That analysis demonstrated that the 6 hour testing allowance does not significantly reduce the probability that the RCIC will initiate when necessary. Because the Ref. 1 analysis made no assumptions regarding the elapsed time between testing of consecutive channels in the same logic, it is not necessary to remove mpers/relay blocks or reconnect lifted leads used to prevent a uation of the trip logic during testing of logic channels with inst ments in series solely for the purpose of administering the AOT ocks, provided that the AOT allowance is not exceeded on a per in trument channel basis.
SR  3.3.5.~ .1 Performance of the CHANNEL CHECK ensures that a gross                  {
failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a parameter on other similar channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.
(continued)
DAEC                              B 3.3-148                                  TSGR 120
 
BASES 83.3.5.\
RCIC System Instrumentation SURVEILLANCE REQUIREMENTS Agreem nt criteria are determined by the plant staff based on a combi tion of the channel instrument uncertainties, including indic ion and readability. If a channel is outside the criteria, it may e an indication that the instrument has drifted outside its limi.
T e Surveillance Frequency is controlled under the Surveillance requency Control Program. The Frequency is based upon r
operating experience that demonstrates channel failure is rare .
The CHANNEL CHECK supplements less formal, but more frequent, checks of channels during normal operational use of the displays associated with the channels required by the LCO.
A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the channel will perform the intended function . A successful test of the required contact(s) of a channel relay may be performed by the verification of the change of state of a single contact of the relay. This clarifies what is an acceptable CHANNEL FUNCTIONAL TEST of a relay. This is acceptable because all of the other required contacts of the relay are verified by other Technical Specifications and non-Technical Specifications tests at least once per refueling interval with plicable extenstions.
The        illance Frequency is controlled under the Surveillance      y Freq ncy          trol Program. The Frequency is based on the          *1 reliabili analysis        eference 1.
A CHANNEL CALIBRATION is a complete check of the instrument loop and the sensor. This test verifies the channel responds to the measured parameter within the necessary range and accuracy. CHANNEL CALIBRATION leaves the channel adjusted to account for instrument drifts between successive calibrations consistent with the plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance          I_,,,
Frequency Control Program. The Frequency is based upon the            1 magnitude of equipment drift in the setpoint analysis.
(continued)
DAEC                          B 3.3-149                                  TSGR 120
 
RCIC System Instrumentation B 3.3.5.~
BASES                                                                      ~
~~~~~===========--=========8                                            ~{
SURVEILLANCE SR    3.3.5.~~
REQUIREMENTS (continued)  The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic for a specific channel. The system functional testing performed in LCO 3.5.3 overlaps this Surveillance to provide complete testing of the safety function.
The Surveillance Frequency is controlled under the Surveillance      V Frequency Control Program. The Frequency is based on the            1 need to perform this Surveillance under the conditions that apply during a plant outage and the potential for an unplanned transient if the Surveillance were performed with the reactor at power.
Operating experience has shown that these components usually pass the Surveillance when performed at this Frequency.            {
REFERENCES  1. GENE-770-06-2, "Addendum to Bases for Changes to Surveillance Test Intervals and Allowed Out-of-Service Times for Selected Instrumentation Technical Specifications," February 1991.
DAEC                        B 3.3-150                                TSCR 120
 
Primary Containment Isolation Instrumentation B 3.3.6.1 BASES APPLICABLE    6.a. Reactor Steam Dome Pressure - High (continued)
SAFETY ANALYSES,    present), yet high enough to preclude spurious isolations of LCO, and      shutdown cooling during system startup and operation and to APPLICABILITY provide sufficient overlap with the low pressure isolations of the HPCI and RCIC turbines to allow the transition to shutdown cooling during plant shutdowns.
This Function isolates the Group 4 valves.
6.b. Reactor Vessel Water Level -      Low Low RPV water level indicates that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, isolation of some reactor vessel interfaces occurs to begin isolating the potential sources of a break. The Reactor Vessel Water Level - Low Function associated with RHR Shutdown Cooling System isolation is not directly assumed in safety analyses because a break of the RHR Shutdown Cooling System is bounded by breaks of the Recirculation Suction and MSL. The RHR Shutdown Cooling System Isolation on Reactor Vessel Water Level-Low supports actions to ensure that the RPV water level does not drop below the top of the active fuel during a vessel draindown event caused by a leak (e.g., pipe break or inadvertent valve opening) in the RHR Shutdown Cooling System when the system is in operation (i.e., the shutdown cooling suction valves are automatically isolated, and if both of the RHR shutdown cooling suction valves are not fully closed and reactor steam dome pressure Is less than 135 psig (nominal), then the two inboard LPCI injection valves are also automatically isolated if a low reactor vessel water level signal is received).
Reactor Vessel Water Level - Low signals are initiated from four level indicating switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels (two channels per trip system) of the Reactor Vessel Water Level - Low Function are available and are required to be OPERABLE to ensure that no single instrument failure can preclude the isolation function. As noted (footnote (f) to Table 3.3.6.1 1 ), only two channels of the Reactor Vessel
              \f\later Level    Low Function are required to be OPERABLE in MODES 4 and 6 (and must be capable of providing input to initiate the isolation of the same division of isolation valves, i.e., both tho (continued)
DAEC                          B 3.3-174                                    TSGR 003
 
Primary Containment Isolation Instrumentation B 3.3.6.1 BASES APPLICABLE    6.b. Reactor Vessel Water Level -      Low (continued)
SAFETY ANALYSES,    /\1 and B1 ohannols or both tho /\2 and B2 ohannols are required LCO, and      to be OPERABLE), provided tho RHR Shutdown Cooling System APPLICABILITY integrity is maintained . System integrity is maintained provided tho pi13ing is intaot and no 013orations with tho potential for draining tho roaster vessel through tho system are being performed.
The Reactor Vessel Water Level - Low Allowable Value was chosen to be the same as the RPS Reactor Vessel Water Level - Low Allowable Value (LCO 3.3.1.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low Function is only required to be OPERABLE in MODE& 3, 4, and 5 to prevent this potential flow path from lowering the reactor vessel level to the top of the fuel. In MODES 1 and 2, another isolation (i.e., Reactor Steam Dome Pressure - High) and administrative controls ensure that this flow path remains isolated to prevent unexpected loss of inventory via this flow path.
This Function isolates the Group 4 valves.
6.c. Drywell Pressure - High High drywell pressure Indicates that the RHR Shutdown Cooling System piping downstream of the inboard isolation valve located in the drywell may have experienced a break. In order to prevent the level in the RPV from dropping below the top of active fuel If this were to occur, this Function will cause the RHR Shutdown Cooling System to isolate if the system is in use (i.e., the shutdown cooling suction valves are automatically isolated, and if both of the RHR shutdown cooling suction valves are not fully closed and reactor steam dome pressure is less than 135 psig (nominal), then the two inboard LPCI injection valves are also automatically isolated if a high drywell pressure signal is received). The Drywell Pressure - High Function associated with the RHR Shutdown Cooling System isolation is not directly assumed in safety analyses because a break of the RHR Shutdown Cooling system is bounded by breaks of the Recirculation System and MSL.
(continued)
DAEC                          B 3.3-175                                    TSCR 003
 
Secondary Containment Isolation Instrumentation B 3.3.6.2 BASES APPLICABLE    1. Reactor Vessel Water Level-    . Low (continued)
SAFETY ANALYSES,    release. The Reactor Vessel Water Level - Low Function is one LCO, and      of the Functions assumed to be OPERABLE and capable of APPLICABILITY providing isolation and initiation signals. The isolation and initiation systems on and Reactor Vessel Water Level - Low support actions to ensure that any offsite releases are within the limits calculated in the safety analysis.
Reactor Vessel Water Level - Low signals are initiated from level switches that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level - Low Function are available and are requ ired to be OPERABLE to ensure that no single instrument failure can preclude the isolation function .
The Reactor Vessel Water Level-Low Allowable Value was chosen to be the same as the Reactor Protection System Reactor Vessel Level-Low Allowable Value (LCO 3.3.1.1 ), since this provides an early indication that the capability to cool the fuel is being threatened.
The Reactor Vessel Water Level - Low Function is required to be OPERABLE in MODES 1, 2, and 3 where considerable energy exists in the Reactor Coolant System (RCS); thus, there is a probability of pipe breaks resulting in significant releases of radioactive steam and gas. In MODES 4 and 5, the probability and consequences of these events are low due to the RCS pressure and temperature limitations of these MODES; thus, this Function is not required . In addition , tho ~blnction is also roqblirod to bo OPER/\BLE dblring Operations with a Potential for Draining tho Reactor Vassal (OPDRVs) bocablso tho capability of isolating potential soblrcos of leakage mblst bo provided to onsblro that offsito doss limits aro not oxcoodod if corn damage occblrs.
: 2. Drvwell Pressure - High High drywell pressure can indicate a break in the Reactor Coolant Pressure Boundary (RCPB). An isolation of the secondary containment and actuation of the SBGT System are initiated in order to minimize the potential of an offsite dose release.
(continued)
DAEC                          B 3.3-193                              /\mendment 223
 
SFU System Instrumentation B 3.3.7.1 BASES APPLICABLE    Control Building Intake Area Radiation -      High (continued)
SAFETY ANALYSES,    The Control Building Intake Area Radiation - High Function is LCO, and      required to be OPERABLE in MODES 1, 2, and 3 and during APPLICABILITY CORE ALTERATIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, to ensure that control room personnel are protected during a LOCA, fuel handling event, or vessel draindown event. During MODES 4 and 5, when these specified conditions are not in progress (e.g., CORE AL TERATIONS), the probability of a LOCA or fuel damage is low; thus, the Function is not required.
ACTIONS      A Note has been provided to modify the ACTIONS related to SFU System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate entry Into the Condition.
Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable SFU System instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable SFU System instrumentation channel.
A.1. and A.2 With a Control Building Intake Area Radiation-High Channel inoperable, the initiation capability of the associated SFU subsystem is lost. Therefore, the associated SFU subsystem(s) must be declared inoperable within 1 hour per Required Action A.1, or must be placed in the isolation mode of operation, (i.e., the SFU in operation and the Control Building Ventilation System isolated, within 1 hour per Required Action A.2. Placing the subsystem in the isolation mode ensures that control room personnel will be protected in the event of a Design Basis Accident. The method used to place the SFU subsystem(s) in operation must provide for automatically re-initiating the subsystem(s) upon restoration of power following a loss of power to the SFU subsystem(s).
(continued)
DAEC                          B 3.3-211                              Amendment 22d
 
I RPV WATER INVENTORY CONTROL,                                              ECCS -Operating B 3.5.1 B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM B 3.5.1 ECCS -  Operating BASES BACKGROUND        The ECCS is designed, in conjunction with the primary and secondary containment, to limit the release of radioactive materials to the environment following a Loss of Coolant Accident (LOCA). The ECCS uses two independent methods (flooding and spraying) to cool the core during a LOCA. The ECCS network consists of the High Pressure Coolant Injection (HPCI) System, the Core Spray (CS) System, the Low Pressure Coolant Injection (LPCI) mode of the Residual Heat Removal (RHR) System, and the Automatic Depressurization System (ADS). The suppression pool provides the required source of water for the ECCS.
Although no credit is taken in the safety analyses for the Condensate Storage Tank (CST), it is capable of providing a source of water for the HPCI and CS systems.
On receipt of an initiation signal, after the appropriate time delays for the Diesel Generators (DGs) to start and provide power to the 4160 VAC bus, assuming the concurrent Loss of Offsite Power (LOOP), ECCS pumps automatically start; the system aligns and the pumps inject water, taken either from the CST or suppression pool, into the Reactor Coolant System (RCS) as RCS pressure is overcome by the discharge pressure of the ECCS pumps.
Although the system is initiated, ADS action is delayed, allowing the operator to interrupt the timed sequence if the system is not needed. The HPCI pump discharge pressure almost immediately exceeds that of the RCS, and the pump injects coolant into the vessel to cool the core. If the break is small, the HPCI System will maintain coolant inventory as well as vessel level while the RCS is still pressurized. If HPCI fails, it is backed up by ADS in combination with LPCI and CS. In this event, the ADS timed sequence would be allowed to time out and open the selected Safety Relief Valves (SRVs) depressurizing the RCS, thus allowing the LPCI and CS to overcome RCS pressure and inject coolant into the vessel. If the break is large, RCS pressure initially drops rapidly precluding HPCI from injecting to the vessel, and the LPCI and CS subsystems cool the core.
(continued)
DAEC                                B 3.5-1                              Amendment 223
 
ECCS -  Operating B 3.5.1 BASES LCO          Each ECCS injection/spray subsystem and four ADS valves are required to be OPERABLE. The ECCS injection/spray subsystems are defined as the two CS subsystems, the LPCI System, and one HPCI System. The low pressure ECCS subsystems are defined as the two CS subsystems and the LPCI System. Management of gas voids is important to ECCS injection/spray subsystem OPERABILITY.
t With less than the required number of ECCS subsystems OPERABLE, the potential exists that during a limiting design basis LOCA concurrent with the worst case single failure, the limits specified in Reference 1O could be exceeded. All ECCS subsystems must therefore be OPERABLE to satisfy the single failure criterion required by Reference 10.
The LPCI System may be considered OPERABLE during alignment and operation for decay heat removal (i.e.- Shutdown Cooling) when below the actual RHR Shutdown Cooling interlock pressure in MODE 3, if capable of being manually realigned (remote or local) to the LPCI mode and not otherwise inoperable.
At these low pressures and decay heat levels, a reduced complement of ECCS subsystems should provide the required core cooling, thereby allowing operation of RHR shutdown cooling when necessary. In addition, the risk of a LOCA during the transition from the RHR interlock pressure to cold shutdown is minimal.
APPLICABILITY All ECCS subsystems are required to be OPERABLE during MODES 1, 2, and 3, when there is considerable energy in the reactor core and core cooling would be required to prevent fuel damage in the event of a break in the primary system piping. In MODES 2 and 3, when reactor steam dome pressure is
:::; 150 psig, HPCI is not required to be OPERABLE because the low pressure ECCS subsystems can provide sufficient flow below this pressure. In MODES 2 and 3, when reactor steam dome pressure is :::; 100 psig, ADS is not required to be OPERABLE because the low pressure ECCS subsystems can provide sufficient flow below this pressure. ECCS requirements for MODES 4 and 5 are specified in LCO 3.5.2, "EGGS Shutdown ."
                                            "RPV Water Inventory Control."
(continued)
DAEC                            B3.5-6                                  TSGR 146
 
INSERT B-1 (3.5.2 Analyses)
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses. RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material to the environment should an unexpected draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure, reduced piping stresses, and ductile piping systems. Instead, an event is considered in which single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g., seismic event, loss of normal power, single human error). It is assumed, based on engineering judgment, that while in MODES 4 and 5, one low pressure ECCS injection/spray subsystem can maintain adequate reactor vessel water level.
As discussed in References 1, 2, 3, 4, and 5, operating experience has shown RPV water inventory to be significant to public health and safety. Therefore, RPV Water Inventory Control satisfies Criterion 4of10 CFR 50.36(c)(2)(ii).
INSERT B-2 (3.5.2 LCO)
The RPV water level must be controlled in MODES 4 and 5 to ensure that if an unexpected draining event should occur, the reactor coolant water level remains above the top of the active irradiated fuel as required by Safety Limit 2.1.1.3 The Limiting Condition for Operation (LCO) requires the DRAIN TIME of RPV water inventory to the TAF to be c:: 36 hours. A DRAIN TIME of 36 hours is considered reasonable to identify and initiate action to mitigate unexpected draining of reactor coolant. An event that could cause loss of RPV water inventory and result in the RPVwater level reaching the TAF in greaterthan 36 hours does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
One low pressure ECCS injection/spray subsystem is required to be OPERABLE and capable of being manually started to provide defense-in- depth should an unexpected draining event occur. A low pressure ECCS injection/spray subsystem consists of either one Core Spray (CS) subsystem or one Low Pressure Coolant Injection (LPCI) subsystem. Each CS subsystem consists of one motor driven pump, piping, and valves to transfer water from the suppression pool or condensate storage tank (CST) to the RPV. Each LPCI subsystem consists of one motor driven pump, piping, and valves to transfer water from the suppression pool to the RPV.
In MODES 4 and 5, the RHR System cross tie valve is not required to be closed.
The LCO is modified by a Note which allows a required LPCI subsystem to be considered OPERABLE during alignment and operation for decay heat removal if capable of being manually realigned (remote or local) to the LPCI mode and is not otherwise inoperable.
Alignment and operation for decay heat removal includes when the required RHR pump is not operating or when the system is realigned from or to the RHR shutdown cooling mode. This allowance is necessary since the RHR System may be required to operate in the shutdown cooling mode to remove decay heat and sensible heatfrom the reactor. Because of the restrictions on DRAIN TIME, sufficient time will be available following an unexpected draining event to manually align and initiate LPCI subsystem operation to maintain RPV water inventory prior to the RPV water level reaching the TAF.
 
INSERT B-3 (3.5.2 ACTIONS)
A.1 and B.1 If the required low pressure ECCS injection/spray subsystem is inoperable, it must be restored to OPERABLE status within 4 hours. In this Condition, the LCO controls on DRAIN TIME minimize the possibility that an unexpected draining event could necessitate the use of the ECCS injection/spray subsystem, however the defense-in-depth provided by the ECCS injection/spray subsystem is lost. The 4 hour Completion Time for restoring the required low pressure ECCS injection/spray subsystem to OPERABLE status is based on engineering judgment that considers the LCO controls on DRAIN TIME and the low probability of an unexpected draining event that would result in loss of RPV water inventory.
If the inoperable ECCS injection/spray subsystem is not restored to OPERABLE status within the required Completion Time, action must be initiated immediately to establish a method of water injection capable of operating without offsite electrical power. The method of water injection includes the necessary instrumentation and controls, water sources, and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The method of water injection may be manually initiated and may consist of one or more systems or subsystems, and must be able to access water inventory capable of maintaining the RPV water level above the TAF for;;::: 36 hours. If recirculation of injected water would occur, it may be credited in determining the necessary water volume.
C.1. C.2. and C.3 With the DRAIN TIME less than 36 hours but greaterthan or equal to 8 hours, compensatory measures should be taken to ensure the ability to implement mitigating actions should an unexpected draining event occur. Should a draining event lower the reactor coolant level to below the T AF, there is potential for damage to the reactor fuel cladding and release of radioactive material. Additional actions are taken to ensure that radioactive material will be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a controlled volume in which fission products can be contained, diluted, and processed prior to release to the environment. Required Action C.1 requires verification of the capability to establish the secondary containment boundary in less than the DRAIN TIME. The required verification confirms actions to establish the secondary containment boundary are preplanned and necessary materials are available. The secondary containment boundary is considered established when one Standby Gas Treatment (SBGT) subsystem is capable of maintaining a negative pressure in the secondary containment with respect to the environment.
Verification that the secondary containment boundary can be established must be performed within 4 hours. The required verification is an administrative activity and does not require manipulation or testing of equipment. Secondary containment penetration flow paths form a part of the secondary containment boundary. Required Action C.2 requires verification of the capability to isolate each secondary containment penetration flow path in less than the DRAIN TIME. The required verification confirms actions to isolate the secondary containment penetration flow paths are preplanned and necessary
 
materials are available. Power operated valves are not required to receive automatic isolation signals if they can be closed manually \Mthin the required time. Verification that the secondary containment penetration flow paths can be isolated must be performed within 4 hours. The required verification is an administrative activity and does not require manipulation or testing of equipment.
One SBGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action C.3 requires verification of the capability to place one SBGT subsystem in operation in less than the DRAIN TIME. The required verification confirms actions to place a SBGT subsystem in operation are preplanned and necessary materials are available. Verification that a SBGT subsystem can be placed in operation must be performed within 4 hours. The required verification is an administrative activity and does not require manipulation or testing of equipment.
D.1. D.2. D.3. and D.4 With the DRAIN TIME less than 8 hours, mitigating actions are implemented in case an unexpected draining event should occur. Note that ifthe DRAIN TIME is less than 1 hour, Required Action E.1 is also applicable.
Required Action D.1 requires immediate action to establish an additional method of water injection augmenting the ECCS injection/spray subsystem required by the LCO.
The additional method of water injection includes the necessary instrumentation and controls, water sources, and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The Note to Required Action D.1 states that either the ECCS injection/spray subsystem or the additional method of water injection must be capable of operating \Mthout offsite electrical power.
The additional method of water Injection may be manually initiated and may consist of one or more systems or subsystems. The additional method of water injection must be able to access water inventory capable of being injected to maintain the RPV water level above the TAF for~ 36 hours. The additional method of water injection and the ECCS Injection/spray subsystem may share all or part of the same water sources. If recirculation of injected water would occur, it may be credited in determining the required water volume.
Should a draining event lower the reactor coolant level to below the TAF, there is potential for damage to the reactor fuel cladding and release of radioactive material.
Additional actions are taken to ensure that radioactive material \1\411 be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a control volume in which fission products can be contained, diluted, and processed prior to release to the environment. Required Action D.2 requires that actions be immediately initiated to establish the secondary containment boundary. With the secondary containment boundary established, one SBGT subsystem is capable of maintaining a negative pressure in the secondary containment
\Mth respect to the environment.
The secondary containment penetrations form a part of the secondary containment boundary. Required Action D.3 requires that actions be immediately initiated to verify that each secondary containment penetration flow path is isolated or to verify that it can be manually isolated from the control room.
 
One SBGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action D.4 requires that actions be immediately initiated to verify that at least one SBGT subsystem is capable of being placed in operation. The required verification is an administrative activity and does not require manipulation or testing of equipment.
E.1 If the Required Actions and associated Completion times of Conditions C or Dare not met or ifthe DRAIN TIME is less than 1 hour, actions must be initiated immediately to restore the DRAIN TIME to;:::: 36 hours. In this condition, there may be insufficient time to respond to an unexpected draining eventto preventthe RPV water inventory from reaching the TAF. Note that Required Actions D.1, D.2, D.3, and D.4 are also applicable when DRAIN TIME is less than 1 hour.
INSERT B-4 (SR3.5.2.1}
This Surveillance verifies that the DRAIN TIME of RPV water inventory to the TAF is
    ;:::: 36 hours. The period of 36 hours is considered reasonable to identify and initiate action to mitigate draining of reactor coolant. Loss of RPV water inventory that would result in the RPV water level reaching the TAF in greater than 36 hours does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
The definition of DRAIN TIME states that realistic cross-sectional areas and drain rates are used in the calculation. A realistic drain rate may be determined using a single, step-wise, or Integrated calculation considering the changing RPV water level during a draining event. For a Control Rod RPV penetration flow path with the Control Rod Drive Mechanism removed and not replaced with a blank flange, the realistic cross-sectional area is based on the control rod blade seated in the control rod guide tube. If the control rod blade will be raised from the penetration to adjust or verify seating of the blade, the exposed cross-sectional area of the RPV penetration flow path is used.
The definition of DRAIN TIME excludes from the calculation those penetration flow paths connected to an intact closed system, or isolated by manual or automatic valves that are locked, sealed, or otherwise secured in the closed position, blank flanges, or other devices that prevent flow of reactor coolant through the penetration flow paths. A blank flange or other bolted device must be connected with a sufficient number of bolts to prevent draining In the event of an Operating Basis Earthquake. Normal or expected leakage from closed systems or past isolation devices is permitted. Determination that a system is intact and closed or isolated must consider the status of branch lines and ongoing plant maintenance and testing activities.
The Residual Heat Removal (RHR) Shutdov...n Cooling System is only considered an intact closed system when misalignment issues (Reference 6) have been precluded by functional valve interlocks or by isolation devices, such that redirection of RPV water out of an RHR subsystem is precluded. Further, RHR Shutdov...n Cooling System is only considered an intact closed system if its controls have not been transferred to Remote Shutdov...n, which disables the interlocks and isolation signals.
 
The exclusion of penetration flow paths from the determination of DRAIN TIME must consider the potential effects of a single operator error or initiating event on items supporting maintenance and testing (rigging, scaffolding, temporary shielding, piping plugs, snubber removal, freeze seals, etc.). If failure of such items could result and would cause a draining event from a closed system or between the RPV and the isolation device, the penetration flow path may not be excluded from the DRAIN TIME calculation.
Surveillance Requirement3.0.1 requires SRs to be met between performances.
Therefore, any changes in plant conditions that would change the DRAIN TIME requires that a new DRAIN TIME be determined.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
INSERT B-5 (SR 3.5.2.6-8)
SR 3.5.2.6 Verifying that the required ECCS injection/spray subsystem can be manually started and operate for at least 1O minutes demonstrates that the subsystem is available to mitigate a draining event. Testing the ECCS injection/spray subsystem through the recirculation line is necessary to avoid overfilling the refueling cavity. The minimum operating time of 10 minutes was based on engineering judgment. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.7 Verifying that each valve credited for automatically isolating a penetration flow path actuates to the isolation position on an actual or simulated RPV water level isolation signal is required to prevent RPV water inventory from dropping below the T AF should an unexpected draining event occur. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
 
INSERT B-6 (3.5.2 REF)
: 1. Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup," November 1984.
: 2. Information Notice 86-74, "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves," August 1986.
: 3. Generic Letter 92-04, "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10CFR50.54(f), "August 1992.
: 4. NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs," May 1993.
: 5. Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1," July 1994.
: 6. General Electric Service Information Letter No. 388, "RHR Valve Misalignment During Shutdown Cooling Operation for BWR 3/4/5/6," February 1983.
 
jRPV Water Inventory Control ~
                                      , RPV WATER INVENTORY                                  EGGS      Shutdown CONTROL,                                                            B 3.5.2 B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM B 3.5.2 EGGS          Shutdown      .?----iReactor Pressure Vessel (RPV)
Water Inventory Control BASES BACKGROU ~              A description of tho Coro Spray (CS) System is provided in tho Bases for LCO 3.5.1, "EGGS Operating".                              .
The RPV contains penetrations below the top of the a~tive fuel _(TAF) that      Tho Low Pressure Coolant Injection (LPCI) Mode of tho Residual have the potential to dram the reactor                                                    .  .        .
coolant inventory to below the TAF If      Heat Removal (RHR) System, for tho application of this the water level should drop below the      specification , takes on a ~ifforont dofinit~on}han is doscr!bo~ in TAF, the ability to remove decay heat      tho Bases for LCO 3.5.1 EGGS Operating . In tho appllcat10~ of is reduced , which could lead to .          "EGGS Shutdown", tho 10 .v pressure EGGS subsystems consist of 1
elevated cladding temperatures and          two CS subsystems and two LPCI subsystems. Each LPCI clad perforation . Safety Limit 2 .1.1.3    subsystem consists of one motor driven RHR pump, piping , and requires the RPV water level to be          valves to transfer water from tho suppression pool to tho Reactor above the top of the active irradiated      Pressure Vessel (RPV). Only a single RHR pump is required per fuel at all times to prevent such          subsystem because of tho larger injection capacity in relation to a elevated cladding temperatures              cs subsystem.
APPLICABLE              Tho EGGS performance is evaluated for tho entire spectrum of SAFETY                  break sizes for a postulated Loss of Coolant Aeeidont (LOCA).
ANALYSES                Tho long term cooling analysis following a design basis LOCA (Ref. 1) demonstrates that only one low pressure EGGS pump is required , post LOCA, to maintain adequate roaster vessel water lo\<ol. It is reasonable to assume , based on engineering judgement, that Vv'hile in MODES 4 and 5, one low pressure EGGS subsystem can maintain adequate reactor vessel water level. To provide redundancy, a minimum of two loi.v pressure EGGS subsystems are required to be OPERABLE in MODES 4 and 5.
Tho low pressure EGGS subsystems satisfy Criterion 3 of 10 CfR 50.3e(c)(2)(ii).
LCO                      Two low pressure EGGS subsystems are required to be OPERABLE. for this specification, tho lov1 pressure EGGS jiNSERT B-2 (3.5.2 LCO) ~                subsystems consist of two CS subsystems and two LPCI subsystems. Each CS subsystem consists of one motor driven pump, piping, and valves to transfer water from tho suppression pool or Condensate Storage Tank (CST) to tho Reactor Pressure (continued)
DAEC                                      B 3.5-21                          Amendment 223
 
IRPV Water Inventory Control
                                                                                                ~ EGGS              Sh!:Atdown B 3.5.2 BASES LCO                Vessel (RPV)*. Eash LPCI subsystem sonsists of one motor (continued)      driven Rl=4R pump, piping , and valves to transfer water from tho suppression pool to tho RPV. Only a single Rl=4R pump is required per s1:Absystom bosa1:Aso of tho larger injection capacity in relation to a CS s1:Absystem . In MODES 4 and 5, the Rl=4R System cross tie valve is not roq1:Airod to be open . Management of gas voids is important to EGGS injection/spray subsystem OPERABILITY. Tho necessary portions of Emergency Service 1
                                  'Nater are also roq1:Airod to provide appropriate cooling to each roq1:Aired CS Sl:Absystom. Ono LPCI s1:Absystom may be aligned for decay heat removal and considered OPERABLE for tho EGGS fl:Anction , if it can be man1:Aally realigned (remote or local) to tho LPCI mode and is not otherwise inoperable. Boca1:Aso of low pressure and low tomporat1:Aro conditions in MODES 4 and 5, Sl:Afficiont time 'Nill be available to man1:Aally align and initiate LPCI Sl:Absystom operation to provide core cooling prior to post1:Alatod fl:AOl l:AnCOVOry.
* Qi,iriA1 Rsfi,isl Gi,itaJs (RFG) 2a , tl:is Ga FRiAiFRt,tFR flew patl:i is Ast reE:Ji,iireel ts Bs availaBls fer Ga te Bs seAsielereEl GPeRAQbe.
OPERABILITY of tho low pressure EGGS subsystems is required in MODES 4 and 5 to ensure adequate soolant inventory and RPV water inventory control is suffisiont heat removal sapability for the irradiated fuel in the sore required in MODES 4 and 5.
in sase of an inadvertent draindown of the vessel. Requirements Requirements on water inventory    for EGGS OPERABILITY dl:Aring MODES 1, 2, and aare control in other MODES are        dissussod in tho Applisability sestion of tho Bases for LCO a.5.1.
contained in LCOs in Section 3.3,  EGGS sl:Absystoms are not roq1:Airod to be OPERABLE d1:Aring Instrumentation, and other LCOs    MODE 5 with tho spent fl:Aol storage pool gates removed and tho in Section 3.5, ECCS, RCIC , and  water level maintained at~ 211=t 1 inch above tho RPV flange .
RPV Water Inventory Control.      This provides sl:Afficiont coolant inventory to allow operator astion RPV water inventory control is    to terminate tho inventory loss prior to fl:Aol l:Ancovor in case of an required to protect Safety Limit    inadvertent draindown.                                                                      *.
2.1.1.3 which is applicable whenever irradiated fuel is in the  Tho Automatic Doprossl:Arization System is not roq1:Airod to be reactor vessel.
OPERABLE dl:Aring MODES 4 and 5 bocal:ASO tho RPV prossl:ArO is
                                    ~ 100 psig , and tho CS and LPCI Sl:Absystoms san provide core cooling .vitho1:At any dopross1:Arization of tho primary system.
1 Tho 1=4igh Pressure Coolant Injection System is not required to be OPERABLE during MODES 4 and 5 since tho low prossl:Aro EGGS subsystems san provide Sl:Affisiont flow to tho vessel and bosa1:Aso ins1:Afficiont reactor pressure is available to drive tho 1=4PCI t1:Arbino.
(continued)
DAEC                                      B 3.5-22                                                  TSCR 146
 
RPV Water Inventory          ~ \.
I
                            ~.c_o_n_tr_ol~~~~~~~~I            ~ E~ c~
c~g..--~g~h~u~
td~o~
w~n B 3.5.2 INSERT B-3 (3.5.2 ACTIONS)
BASES (continued)
ACTIONS          A.1 and B.1 If any one required low pressure Eccg subsystem is inoperable, the inoperable subsystem must be restored to OPER/\BLE status in 4 hours. In this condition , tho remaining OPERABLE subsystem can provide sut=ficiont vessel flooding capability to recover from an inadvertent vessel draindown. However, O'Jorall system reliability is reduced because a single failure in tho remaining OPERABLE subsystem concurrent with a vessel draindown could result in tho Eccg not being able to perform its intended function . Tho 4 hour Completion Time for restoring tho required low pressure Eccg subsystem to OPERABLE status is based on engineering judgment that considered tho remaining available subsystem and tho lov,i probability of a vessel draindown event.
With tho inoperable subsystem not restored to OPERABLE status in tho required Completion Time, action must be immediately initiated to suspend Operations with a Potential for Draining tho Reactor Vessel (OPDRVs) to minimize tho probability of a vessel draindown and the subsequent potential for fission product release . Actions must continue until OPDRVs are suspended .
c .1. c .2. 0 .1. 0 .2. and o.a With both of tho required Eccg subsystems inoperable, all coolant inventory malmup oapability may be unavailable .
Therefore, actions must immediately be initiated to suspend OPDR\,Ls to minimize tho probability of a vessel draindown and tho subsequent potential for fission product release. Actions must continue until OPDR'Js are suspended . Ono Eccg subsystem must also bo restored to OPERABLE status within 4 hours.
If at least one low pressure Eccg subsystem is not restored to OPERABLE status within tho 4 hour Completion Time, additional actions are required to minimize any potential fission product release to tho environment. This includes ensuring secondary containment is OPERABLE; one standby gas treatment subsystem is OPERABLE; and secondary containment isolation capability for each associated secondary containment penetration flow path not isolated that is assumed to be isolated to mitigate (continued)
DAEC                                B 3.5-23                        Amendment 223
 
                                                                    ~e\G-: :> G..aS  1c:i ...--.S:!t -ht : 1u~td:H:iO,. . 'l1n+
IRPV Water Inventory Control B 3.5.2 BASES ACTIONS          G.1, G.2. D.1. D.2. and D.a (sontinued) radioastivity releases is available (i.e., at least one sosondary sontainment isolation valve or damper and assosiated instrumentation are OPERABLE, or other assoptablo administrative controls to assure isolation capability. Those administrative controls consist of stationing a dedicated operator who is in continuous communications with tho control room , at tho controls of tho isolation device . In this way, tho penetration can be rapidly isolated i,vhon a nood for secondary containment isolation is indicated). OPERABILITY may bo verified by an administrative chock, or by examining logs or other information, to dotormino 1Nhothor tho components aro out of service for maintenance or othor reasons . It is not necessary to perform tho Surveillances needed to demonstrate tho OPERABILITY of tho components. If, however, any required component is inoperable, then it must bo rostorod to OPERABLE status. In this caso , tho Surveillance may nood to bo performed to restore the component to OPERABLE status. Actions must continue until all required components are OPERABLE.
Tho 4 hour Gomplotion Time to restore at least one low pressure EGGS subsystem to OPERABLE status ensures that prompt action will be tal(on to provide the required cooling capacity or to initiate actions to place the plant in a condition that minimizes any potential fission product release to tho environment.
!INSERT B-4(SR3.5.2.1)1-I- -)-+            &#xa3;]                ~
SURVEILLANCE    SR 3.5.2.4-and SR 3.5 . 2.~
REQUIREMENTS The minimum water level of 7.0 ft required for the suppression pool is periodically verified to ensure that the suppression pool will provide adequate Net Positive Suction Head (NPSH) for the LPCI
    !subsystem pump 1----7) System pumps, recirculation volume, and vortex prevention. With the suppression pool water level less than the required limit, the LPCI subsystem(s) is (aro) inoperable.                                    ~
                                                ~                                                        ~
(continued)
DAEC                              B 3.5-24                              Amendment 223
 
IRPV Water Inventory Control            ~
EGGS      Sh1:1tdown B 3.5.2 BASES SURVEILLANCE            SR 3.5.2.4 and SR 3.5.2. ~ (continued)                required CS subsystem REQUIREMENTS When suppression pool level is < 8.0 ft, e CS S;istem is considered OPERABLE only if it can ta e suction from the CST, and the CST water level is sufficient t provide the required NPSH for the CS pump. Therefore, a verifi ation that either the suppression pool water level is 2 8. ft or that GS-is aligned to take suction from the CSTs and th CSTs co                  in 2 75,000 gallons of water, equiv            nt to 11 ft i one CST or 2 7 ft in both CSTs, ensures that the GS S;istem can upply at least 75,000 gallons of makeup water to the RPV. f=l-Qwe-Y-SF-:-al~:HS43":-
The flow path piping has the potential to develop voids and pockets of entrained air. Maintaining the pump a required CS subsystem discharge lines of the required ECCS injection/spray subsystems full of        The Surveillance Frequency is controlled under the Surveillance water ensures that the ECCS              Frequency Control Program. Tho F'roq1:1onc;i of those SRs was subsystem will perform properly. This    developed considering operating experience related to may also prevent a water hammer s1:1ppression pool water level and CST water levol 111ariations following an ECCS initiation signal.
One acceptable method of ensuring d1:1ring tho applicable MODES. F'1:1rthermoro, tho F'roq1:1onc;i is that the lines are full is to vent at the oonsidered adequate in 1iew of other indications available in tho 1
high points. The Surveillance            oontrol room to alert the operator to an abnormal s1:1ppression pool Frequency is controlled under the        or CST water level oondltion .
Surveillance Frequency Control Program.                                                                                    JJ!J SR 3.6.2.3, SR 3.6.2.6, and SR 3.5.2.e Tho Bases provided for SR 3.5.1.1, SR 3.5.1.4 , and SR 3.5.1.7 are applicable to SR 3.5.2.3, SR 3.5.2.5, and SR 3.5.2.6, respoctivol;i.
SR 3.5.2.4 ~
                                                                          !subsystem I Verifying th ,_o_r""-re-c-.-.vgnment for power operated and automatic valves in the ECCS ow paths provides assurance that the proper y flow paths w* 0*ist for ECCS operation.L This SR does not apply ' I to valve      a are locked, sealed, or otherwise secured in position, si        ese valves were verified to be in the correct position prior be available      o locking, sealing, or securing. A valve that receives an initiation signal is allowed to be in a nonaccident position provided the
                                          ~n&sect; Refl:tel 01:1ta&sect;e (RFO) 2J, the CS FRiniFRl:lFR flaw 13ath is net req1:1ireel to ~
ee availaele fer CS ta ee eansielereel OP!!RABL!!.                                1 (continued)
DAEC                                      B 3.5-25                                        TSCR 135
 
IRPV Water Inventory Control    ~
EGGS      Shutdown B 3.5.2 BASES                        ,
SURVEILLANCE      SR 3.5.2.4-(continued)
REQUIREMENTS valve will automatically reposition in the proper stroke time. This SR does not require any testing or valve manipulation; rather, it involves verification that those valves capable of potentially being mispositioned are in the correct position. This SR does not apply to manual valves unless the valves are being manipulated to serve as all or part of a system vent flow path opened under administrative control, as described in the SR Note (and Bases paragraph below). In this case, the SR Note allows the licensee to credit administratively controlled manual action to close the system vent flow path in order to maintain system Operability during system venting and performance of the gas accumulation SR. This SR does not apply to valves that cannot be inadvertently misaligned, such as check valves. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
* The Frequency is appropriate because the valves are operated under procedural control and the probability of their being mispositioned during this time period is low.
The Surveillance is modified by a Note which exempts system vent flow paths opened under administrative control. The administrative control should be proceduralized and include a stationing of a dedicated individual at the system vent flow path who is in continuous communication with the operators in the control room. This individual will have a method to rapidly close the system vent flow path if directed.
la required    In Modes 4 and 5, the RHR System may be required to operate in e shutdown cooling mode to remove decay heat and sensible hea      m the reactor. Therefore, this SR is modified by a Note the restrictions on DRAIN TIME ,
that allo    GR&-LPCI subsystem to be considered OPERABLE sufficient time will be available    during alignment and operation for decay heat removal, if capable following an unexpected draining    of being manually realigned (remote or local) to the LPCI mode event to manually align and initiate and not otherwise inoperable. Alignment and operation for decay LPCI subsystem operation to maintain heat removal includes when the required RHR pump is not RPV water inventory prior to the RPV operating or when the system is realigned from or to the RHR water level reaching the TAF          hutdown cooling mode. Because of the lovv pressure and low
                                                                                ' subsystem operation available to manually align and initiate LPGI to provide com coverage prior to postulated fuel uncoveF)'. This jiNSERT B-5 (SR 3.5.2.6-8)          will ensure adequate core cooling if an inadvertent RPV draindovim should~
INSERT B-6 (3.5.2 REF)
I REFERENCES      +.  ~Section 15.2.1.1.
DAEC                              B 3.5-26                                  TSGR 167
 
        , RPV WATER INVENTORY CONTROL, RCIC System B 3.5.3 B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM B 3.5.3 RCIC System BASES BACKGROUND        The RCIC System is not part of the ECCS; however, the RCIC System is included with the ECCS section because of their similar functions.
The RCIC System is designed to operate either automatically or manually following Reactor Pressure Vessel (RPV) isolation accompanied by a loss of coolant flow from the Feedwater System to provide adequate core cooling and control of the RPV water level. Under these conditions, the High Pressure Coolant Injection (HPCI) and RCIC Systems perform similar functions.
The RCIC System design requirements ensure that the criteria of Reference 1 are satisfied.
The RCIC System (Ref. 2) consists of a steam driven turbine pump unit, piping, and valves to provide steam to the turbine, as well as piping and valves to transfer water from the suction source to the core via the Feedwater System line, where the coolant is distributed within the RPV through the Feedwater sparger.
Suction piping is provided from the Condensate Storage Tank (CST) and the suppression pool. Pump suction is normally aligned to the CST to minimize injection of suppression pool water into the RPV. However, if the CST water supply is low, an automatic transfer to the suppression pool water source ensures a water supply for continuous operation of the RCIC System. The steam supply to the turbine Is piped from a main steam line upstream of the associated inboard Main Steam line Isolation Valve.
The RCIC System is designed to provide core cooling for a wide range of reactor pressures 150 psig to 1120 psig. Upon receipt of an initiation signal, the RCIC turbine accelerates to a specified speed. As the RCIC flow increases, the turbine control valve is automatically adjusted to maintain design flow. Exhaust steam from the RCIC turbine is discharged to the suppression pool. A full flow test line is provided to route water from and to the CST to allow testing of the RCIC System during normal operation without injecting water into the RPV.
(continued)
DAEC                                B 3.5-27                            Amendment 22d
 
RCIC System B 3.5.3 BASES BACKGROUND          The RCIC pump is provided with a minimum flow bypass line, (continued)      which discharges to the suppression pool. The valve in this line automatically opens to prevent pump damage due to overheating when other discharge line valves are closed. To ensure rapid delivery of water to the RPV and to minimize water hammer effects, the RCIC System discharge piping is kept full of water.
The RCIC System is normally aligned to the CST. The height of water in the CST is sufficient to maintain the piping full of water up to the first isolation valve. The relative height of the feedwater line connection for RCIC is such that the water in the feedwater lines keeps the remaining portion of the RCIC discharge line full of water. Therefore, RCIC does not require a "keep fill" system when its suction is aligned to the CST. When RCIC suction is aligned to the suppression pool and the system is not in operation, an alternate means of keeping the discharge piping full is required to support system OPERABILITY.
APPLICABLE          The function of the RCIC System is to respond to transient events SAFETY              by providing makeup coolant to the reactor. The RCIC System is ANALYSES            not an Engineered Safety Feature System and no credit is taken in the safety analyses of design basis events for RCIC System operation. Based on its contribution to the reduction of overall plant risk, however, the system satisfies Criterion 4 of 10 CFR 50.36(c)(2)(ii).
LCO                The OPERABILITY of the RCIC System provides adequate core cooling in the event of RPV isolation accompanied by a loss of Feedwater flow. The RCIC System has sufficient capacity for maintaining RPV inventory during an isolation event. Management            X of gas voids is important to RCIC System OPERABILITY.                    /  I APPLICABILITY the low pressure ECCS injection/spray subsystems RPV water inventory control                              can provide sufficient flow to is required by LCO 3.5.2,                                the RPV.
              "RPV Water Level Inventory                                          (continued)
- - - -----iControl .
DAEC                                  B 3.5-28                                    TSGR 146
 
PC IVs B 3.6.1.3 BASES ACTIONS      F.1 and F.2 (continued)
If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours and to MODE 4 within 36 hours. The allowed Completion Times are reasonable, based on operating experience, to reach the required experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
G.1 and G.2 If any Required Action and associated Completion Time cannot be met for PCIVs required to be OPERABLE in MODES 4 or 5, the unit must be placed in a condition in which the LCO does not apply. Action must be immediately initiated to suspend operations with a potential for draining the reactor vessel (OPDRVs) within the Rl9R Shutdown Cooling System boundary to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions m1:1st continue until OPDRVs are suspended and valve(s) are restored to OPERABLE status. If suspending an OPDRV wo1:1ld result in closing the residual heat removal (Rl9R) shutdown cooling Isolation valves, an alternative Required Action is provided to immediately initiate action to restore the valve(s) to OPERl\BU! status. This allmvs Rl9R shutdown cooling to remain in service while actions are being taken to restore the valve.
SURVEILLANCE SR 3.6.1.3.1 REQUIREMENTS This SR ensures that the primary containment purge valves are closed as required or, if open, open for an allowable reason. If a purge valve is open in violation of this SR, the valve is considered inoperable.
If the inoperable valve is not otherwise known to have excessive leakage when closed, it is not considered to have leakage outside of limits. The SR is modified by a Note stating that the SR is not required to be met when the purge valves are open for the stated reasons. The Note states that these valves may be opened for (continued)
DAEC                          B 3.6-25                                    TSCR 104
 
Suppression Pool Water Level B 3.6.2.2 BASES (continued)
APPLICABLE        Initial suppression pool water level affects suppression pool SAFETY            temperature response calculations, calculated drywell pressure ANALYSES          during vent clearing for a OBA, calculated pool swell loads for a OBA LOCA, and calculated loads due to SRV discharges.
Suppression pool water level must be maintained within the limits specified so that the safety analysis of Reference 1 remains valid.
Suppression Pool Water Level satisfies Criteria 2 and 3 of 10 CFR 50.36(c)(2)(ii).
LCO              A limit that suppression pool water level be ~ 10.11 ft and ~ 10.43 ft is required to ensure that the primary containment cond itions assumed for the safety analyses are met. Either the high or low water level limits were used in the safety analyses, depending upon which is more conservative for a particular calculation.
The level requirements also ensure that downcomer submergence is sufficient to ensure condensation effectiveness and prevent steam bypass to the suppression chamber air space and that loads and structural integrity are acceptable.
APPLICABILITY    In MODES 1, 2, and 3, a OBA would cause significant loads on the primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES. The requirements for maintaining suppression pool water level within limits in MODE 4 or 5 is addressed in LCO 3.5.2, "EGGS Shutdown ."
RPV Water Inventory Control (continued)
DAEC                                B 3.6-56                          AITIOAdR'lent 22a
 
Secondary Containment B 3.6.4.1 BASES (continued)
LCO              An OPERABLE secondary containment provides a control volume into which fission products that bypass or leak from primary containment, or are released from the reactor coolant pressure boundary components located in secondary containment, can be diluted and processed prior to release to the environment. For the secondary containment to be considered OPERABLE, it must have adequate leak tightness to ensure that the required vacuum can be established and maintained .
APPLICABILITY    In MODES 1, 2, and 3, a LOCA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, secondary containment OPERABILITY is required during the same operating conditions that require primary containment OPERABILITY.
In MODES 4 and 5, the probability and consequences of the LOCA are reduced due to the pressure and temperature limitations in these MODES. Therefore, maintaining secondary containment OPERABLE is not required in MODE 4 or 5 to ensure a control volume, oxsopt for other situations for whish signifisant releases of radioastive material san be postulated , sush as during Operations with a Potential for Draining tho Roastor Vossol (OPDR\ls).                                                          /'(
ACTIONS          A.1 If secondary containment is inoperable, it must be restored to OPERABLE status within 4 hours. The 4 hour Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining secondary containment during MODES 1, 2, and 3. This time period also ensures that the probability of an accident (requiring secondary containment OPERABILITY) occurring during periods where secondary containment is inoperable is minimal.
(continued)
DAEC                              B 3.6-79                                T8GR 037
 
Secondary Containment B 3.6.4.1 BASES ACTIONS      B.1 and B.2 (continued)
If secondary containment cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours and to MODE 4 within 36 hours. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
OPDRVs can bo postulated to cause fission product reloaso to tho .{
secondary containment. In such cases , tho secondary containment is tho only barrier to tho roloaso of fission products to tho onvironmont.                                                        1' Action must bo immodiatoly initiated to suspend OPDRVs to              ,{
minimize the probability of a vessel drain down and subsequent potential for fission product roloaso . .6tctions must continue until f
OPDRVs aro suspended.
LGO  a.a.a  is not applicable in MODE 4 or 5 when OPDRVs can ooour. Roquirod Action G.1 has been modified by a ~ote stating that LGO  a.a.a  is not applicable.
SURVEILLANCE SR 3.6.4.1.1 and SR 3.6.4.1.2 REQUIREMENTS Verifying that secondary containment equipment hatches (e.g.,
the Refueling Floor roof hatch and the HPCl/RCIC room roof hatches) and that either the outer door(s) or the inner door(s) in each access opening are closed ensures that the infiltration of outside air of such a magnitude as to prevent maintaining the desired negative pressure does not occur. Verifying that all such openings are closed provides adequate assurance that exfiltration from the secondary containment will not occur. Maintaining secondary containment OPERABILITY requires verifying that either the outer door(s) or the inner door(s) in each access opening are closed. However, each secondary containment access door is normally kept closed, except when the access (continued)
DAEC                          B 3.6-80
 
SCIV/Ds B 3.6.4.2 BASES (continued)
APPLICABILITY    In MODES 1, 2, and 3, a OBA could lead to a fission product release to the primary containment that leaks to the secondary containment. Therefore, the OPERABILITY of SCIV/Ds is required.
In MODES 4 and 5, the probability and consequences of these events are reduced due to pressure and temperature limitations in these MODES. Therefore, maintaining SCIV/Ds OPERABLE is not required in MODE 4 or 5, mmept for other sitblations binder which significant radioactive releases can be postbllated, sblch as dblring Operations with a Potential for Draining the Reactor          )"'
Vessel (OPDRVs).                                                        I ACTIONS          The ACTIONS are modified by three Notes. The first Note allows penetration flow paths to be unisolated intermittently under administrative controls. For isolation devices requiring local operation, these controls consist of stationing a dedicated operator, who is in continuous communication with the control room, at the controls of the isolation device. In this way, the penetration can be rapidly Isolated when a need for secondary containment isolation is indicated. For isolation devices that can be operated remotely from the control room, the isolation device handswitch is tagged per plant procedures, identifying that the isolation device is open under administrative control and must be closed should an isolation signal occur. In the event of an isolation signal, plant procedures direct control room operators to verify all automatic actions occur, and to manually initiate those automatic actions that should have occurred but did not. This will ensure the control room operators verify any isolation devices open under administrative control close in response to an isolation signal. If any of the open isolation devices are unable or fail to close automatically, the control room operators will manually close them.
Note 1 also expands upon the allowance of LCO 3.0.5, which would only allow the penetration to be opened for testing, by allowing the penetration to be opened for other operational reasons, such as draining, venting, etc. The second Note provides clarification that for the purpose of this LCO separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition (continued)
DAEC                              B 3.6-85                                  TSGR 0d7
 
SCIV/Ds B 3.6.4.2 BASES (continued)
ACTIONS          C.1 and C.2 (continued)
The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
If any Required Action and associated Completion Time are not met, the plant must be plaoed in a condition in 'Nhich the LCO does not apply. Actions must be immediately initiated to suspend OPDRVs in order to minimize the probability of a vessel draindoi.vn and the subsequent potential for fission product release . Actions must continue until OPDRVs are suspended .
LCO  a.o.a  is not applicable while in MODE 4 or 5 when OPDRVs can occu r. Required Action D.1 has been modified by a ~Jots stating that LCO    a.o.a is not applicable .
SURVEILLANCE      SR 3.6.4.2.1 REQUIREMENTS Verifying that the isolation time of each power operated automatic SCIV/D is within limits Is required to demonstrate OPERABILITY.
The isolation time test ensures that the SCIV/D will isolate in a time period less than or equal to that assumed in the safety analyses. The Surveillance Frequency is controlled under the        .%
Surveillance Frequency Control Program.
* I SR 3.6.4.2.2 Verifying that each automatic SCIV/D closes on a secondary containment isolation signal is required to prevent leakage of radioactive material from secondary containment following a OBA or which are released during certain operations when primary containment is not required to be OPERABLE or take place outside primary containment. This SR ensures that each automatic SCIV/D will actuate to the isolation position on a secondary containment isolation signal. The LOGIC SYSTEM FUNCTIONAL TEST in LCO 3.3.6.2, "Secondary Containment Isolation Instrumentation," overlaps this SR to provide complete testing of the safety function. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
1 The Frequency is based (continued)
DAEC                                B 3.6-88                                TSCR 120
 
SBGT System B 3.6.4.3 BASES (continued)
LCO                Following a OBA, a minimum of one SBGT subsystem is required to maintain the secondary containment at a negative pressure with respect to the environment and to process gaseous releases.
Meeting the LCO requirements for two OPERABLE subsystems ensures operation of at least one SBGT subsystem in the event of a single active failure.
APPLICABILITY    In MODES 1, 2, and 3, a OBA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, SBGT System OPERABILITY is required during these MODES .
In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES. Therefore, maintaining the SBGT System in OPERABLE status is not required in MODE 4 or 5, except for other situations under which significant releases of radioactive material can be postulated, such as during Operations    j 1
A1ith a Potential for Draining the Reactor Vessel (OPDRVs).
ACTIONS          A.1 With one SBGT subsystem inoperable, the inoperable subsystem must be restored to OPERABLE status in 7 days. In this Condition, the remaining OPERABLE SBGT subsystem is adequate to perform the required radioactivity release control function. However, the overall system reliability is reduced because a single failure in the OPERABLE subsystem could result in the radioactivity release control function not being adequately performed. The 7 day Completion Time is based on consideration of such factors as the availability of the OPERABLE redundant SBGT subsystem and the low probability of a OBA occurring during this period.
(continued)
DAEC                                B 3.6-92                            Amendment 22d
 
SBGT System B 3.6.4.3 BASES ACTIONS      B.1 and B.2 (continued)
If the SBGT subsystem cannot be restored to OPERABLE status within the required Completion Time in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours and to MODE 4 within 36 hours. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
C.1 and C.2                                                                ,,(
During OPDRVs, when Required Action A.1 cannot be completed                ,f within tho required Completion Time, tho OPERAgLE sgGT subsystem should Immediately be placed in operation. This action ensures that tho remaining subsystem is OPERAgLE, that no failures that co1::1ld prevent a1::1tomatic actuation have occurred ,
and that any other fail1::1ro .vo1::1ld be readily detected.
1 An alternative to Roq1::1ired Action C.1 is to Immediately s1::1spond aotivities that represent a potential for releasing radioactive material to the secondary containment, thus placing tho plant in a oondition that minimizes risk. If applloable, aotions must                ,,r Immediately be initiated to suspend OPDRVs in order to minimize tho probability of a vessel draindown and s1::1bsoq1::1ont potential for fission produot release . /\otions must oontinue until OPDRVs are s1::1spondod .
LCO 3.0.3 is not applicable in MODE 4 or 5 when OPDRVs can occ1::1r. Tho Roq1::1irod Actions of Condition C ha110 boon modified by a f:>Joto stating that LCO 3.0.3 is not applicable.
If both SBGT subsystems are inoperable in MODE 1, 2, or 3, the SBGT System may not be capable of supporting the required radioactivity release control function. Therefore, actions are required to enter LCO 3.0.3 Immediately.
(continued)
DAEC                            B 3.6-93                                    TSCR 037
 
SBGT System B 3.6.4.3 BASES ACTIONS      g (continued)
When two eBGT subsystems are inoperable, if applioable, aotions must Immediately ee initiated to suspend OPDRVs in order to minimi:z:e the probability of a vessel draindown and subsequent potential for fission produot release . Actions must continue until OPDRVs are suspended .
LCO 3.0.3 is not applicable in MODE 4 or 5 when OPDRVs can occur. Required Action E.1 has boon modified by a ~Joto stating that LCO 3.0.3 is not applicable.
SURVEILLANCE SR 3.6.4.3.1 REQUIREMENTS Operating each SBGT subsystem ensures that both subsystems are OPERABLE and that all associated controls are functioning properly. It also ensures that blockage or fan or motor failure, can be detected for corrective action. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The Frequency was developed in consideration of the known t
reliability of fan motors and controls and the redundancy available in the system, however these components are not the most-limiting for overall system reliability at this SR Frequency.          ~
SR 3.6.4.3.2 This SR verifies that the required SBGT filter testing is performed In accordance with Specification 5.5.7, Ventilation Filter Testing Program (VFTP). The VFTP includes testing HEPA filter performance, charcoal adsorber efficiency, system flow capability, and the physical properties of the activated charcoal (general use and following specific operations). Specific test frequencies and additional information are discussed in detail in the VFTP.
(continued)
DAEC                          B 3.6-94                                  TeCR 142
 
SFU System B 3.7.4 BASES LCO          In order for the SFU subsystems to be considered OPERABLE, (continued)  the CBE boundary must be maintained such that the CBE occupant dose from a large radioactive release does not exceed the calculated dose in the licensing basis consequence analyses for DBAs. In the event of an inoperable CBE boundary in MODES 1, 2, or 3, mitigating actions are required to ensure CBE occupants are protected from hazardous chemicals and smoke.
DAEC does not have automatic SFU actuation for hazardous chemicals or smoke. Current practices at DAEC do not utilize chemicals in sufficient quantity to present a chemical hazard to the CBE. Smoke is not considered in the DAEC safety analysis.
Therefore, there are no specific limits at DAEC for hazardous chemicals or smoke.
The LCO is modified by a Note allowing the CBE boundary to be opened intermittently under administrative controls. This Note only applies to openings in the CBE boundary that can be rapidly restored to the design condition, such as doors, hatches, floor plugs, and access panels. For entry and exit through the doors the administrative control of the opening is performed by the person(s) entering or exiting the area. For other openings these controls should be proceduralized and consist of stationing a dedicated individual at the opening who is in continuous communication with the operators in the CBE. This individual will have a method to rapidly close the opening and to restore the CBE boundary to a condition equivalent to the design condition when a need for CBE isolation is indicated.
APPLICABILITY In MODES 1, 2, and 3, the SFU System must be OPERABLE to ensure that the CBE will remain habitable during and following a 1
OBA, since the OBA could lead to a fission product release.
In MODES 4 and 5, the probability and consequences of a OBA are reduced because of the pressure and temperature limitations in these MODES. Therefore, maintaining the SFU System OPERABLE is not required in MODE 4 or 5, except for the following situations under which significant radioactive releases can be postulated:
During Operations with a Potential for Draining the Reaotor Vessel (OPDRVs);
J (continued)
DAEC                          B 3.7-21                                  TSGR 092
 
SFU System B 3.7.4 BASES f31
              ~
APPLICABILITY    &.-      During CORE ALTERATIONS; and (continued)
During movement of irradiated fuel assemblies in the
            ~~          secondary containment.
ACTIONS          A.1 With one SFU subsystem inoperable, for reasons other than an            J t
inoperable CBE boundary, the inoperable SFU subsystem must              *1 be restored to OPERABLE status within 7 days. With the unit in this condition, the remaining OPERABLE SFU subsystem is adequate to perform the CBE occupant protection function.
However, the overall reliability is reduced because a failure in the OPERABLE subsystem could result in loss of the SFU System function. The 7 day Completion Time is based on the low probability of a DBA occurring during this time period, and that the remaining subsystem can provide the required capabilities.
B.1. B.2. and B.3 If the unfiltered inleakage of potentially contaminated air past the CBE boundary and into the CBE can result in CBE occupant radiological dose greater than the calculated dose of the licensing basis analyses of DBA consequences (allowed to be up to 5 rem TEDE), the CBE boundary is inoperable. As discussed in the Applicable Safety Analyses section, the DAEC licensing basis identifies that CBE inleakage limits for hazardous chemicals and smoke are not necessary to protect the CBE occupants. Allowing verification by administrative means for hazardous chemicals and smoke is considered acceptable, since the limit established for radiological events is the limiting value for determining entry into Condition B for an inoperable CBE boundary. These administrative controls consist of the following:
* Verification that the periodic check of onsite and offsite hazardous chemical sources has been performed within the last year; and
* Verification that the smoke analysis of Reference 7 remains valid and current.
(continued)
DAEC                              B 3.7-22                                  TSCR QQ2
 
SFU System B 3.7.4 BASES ACTIONS      C.1 and C.2 continued)
(continued)                and conditions f om ull power conditions in an orderly manner and without ch lenging unit systems.
D.1, D.2.1. D.2.2. and D.2.3 LCO 3.0.3 is not applicable in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Required Actions of Condition D are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require a reactor shutdown.
0 During  move~l ~f    Jradiated fuel assemblies in the secondary containment; during CORE ALTERATIONS, or during OPDRVs, if the inoperable SFU subsystem cannot be restored to OPERABLE status within the required Completion Time, the OPERABLE SFU subsystem may be placed in the isolation mode (i.e., one SFU subsystem in operation with the control building isolated). This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent automatic actuation will occur, and that any active failure will be readily detected. An alternative to Required Action D.1 is to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the CBE. This places the unit in a condition that          A' minimizes the accident risk.                                          ' I If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also; if applicable, action must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and the subsequent potential for fission product release . Action must oontinue until the OPDRVs are suspended .
* If both SFU subsystems are inoperable in MODE 1, 2, or 3                y for reasons other than an inoperable CBE boundary (i.e.,              /j Condition B), the SFU System may not be capable of performing the intended function and the unit is in a condition outside of the    {'
accident analyses. Therefore, LCO 3.0.3 must be entered immediately.
(continued)
DAEC                          B 3.7-24                                    T8GR 092
 
SFU System B 3.7.4 land      I BASES ACTIONS i
F.1 1 F.2. and F.~
(continued)
LCO 3.0.3 is not applicable in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Required Actions of Condition F are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require a reactors utdown.
or During move      nt of irradiated fuel assemblies in the secondary containment, uring CORE ALTERATIONS, or during OPDRVs, with two SFU subsystems inoperable, or with one or more SFU subsystems inoperable due to an inoperable CBE boundary, action must be taken immediately to suspend activities that present a potential for releasing radioactivity that might require isolation of the CBE. This places the unit in a condition that minimizes the accident risk.
If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. If applicable, action must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release. Action must continue until the OPDRVs are suspended.
SURVEILLANCE    SR 3.7.4.1 REQUIREMENTS Operating each SFU subsystem for z 15 minutes ensures that both subsystems are OPERABLE and that all associated controls are functioning properly. It also ensures that blockage or fan or motor failure, can be detected for corrective action. Since the SFU charcoal is tested at a Relative Humidity z 95%, extended operation of the electric heaters is not required. Thus, each subsystem need only be operated for z 15 minutes to demonstrate the function of each subsystem. The function of the SFU electric heaters is to pre-heat incoming air to above 40&deg;F to ensure adsorption occurs within the temperature range that charcoal testing is performed . The Surveillance Frequency is controlled        y under the Surveillance Frequency Control Program. The                  'I Frequency was developed in consideration of the known reliability of fan motors and controls and the redundancy available in the system.
(continued)
DAEC                            B 3.7-24A                                  TSCR 120
 
CBC System B 3.7.5 BASES (continued)
LCO              Two independent and redundant subsystems of the CBC System are required to be OPERABLE to ensure that at least one is available, assuming a single failure disables the other subsystem.
Total system failure could result in the equipment operating temperature exceeding limits.
The CBC System is considered OPERABLE when the individual components necessary to maintain the control building temperature are OPERABLE in both subsystems. These components include the cooling coils, fans, chillers, compressors, ductwork, dampers, and associated instrumentation and controls.
A CBC is considered inoperable if it trips and cannot be promptly restarted. Therefore, a CBC that spuriously trips and can subsequently be restarted in a reasonable period of time, is not considered inoperable. In addition, during conditions in MODES other than MODES 1, 2, and 3 when the CBC System is required to be OPERABLE (e.g., during CORE ALTERATIONS), the necessary portions of the ESW System, RWS System, and the Ultimate Heat Sink are also required as part of the OPERABILITY requirements covered by this LCO.
APPLICABILITY    In MODE 1, 2, or 3, the CBC System must be OPERABLE to ensure that the control building temperature will not exceed equipment OPERABILITY limits.
In MODES 4 and 5, the probability and consequences of a Design Basis Accident (OBA) are reduced due to the pressure and temperature limitations in these MODES. Therefore, maintaining the CBC System OPERABLE is not required in MODE 4 or 5, except for the following situations under which significant radioactive releases can be postulated:
Dblring Operations with a Potential for Draining the Reactor Vessel (OPDRVs);
During CORE ALTERATIONS; and During movement of irradiated fuel assemblies in the secondary containment.
(continued)
DAEC                              B 3.7-26                            /\rnendrnent 223
 
CBC System B 3.7.5 land BASES ACTIONS
                          \ll D.1. D.2.1. D.2.2. and D.2.d (continued)
LCO 3.0.3 is not applicable in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Required Actions of Condition D are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while r
in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require a reactor shutdown.
Durin~ent            of irradiated fuel assemblies in the secondary containment, during CORE ALTERATIONS, or during OPDRVs, if Required Action A.1 cannot be completed within the required Completion Time, the OPERABLE CBC subsystem may be placed immediately in operation. This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent actuation will occur, and that any active failure will be readily detected.
An alternative to Required Action D.1 is to immediately suspend            ~
activities that present a potential for releasing radioactivity that might requ ire isolation of the control room. This places the unit in a condition that minimizes risk.
If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. /\Isa, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release . Actions must continue until tho
              ~Riis BF9 S"S~9A<l9G.                                                      )
E.1, E.2. and E.d LCO 3.0.3 is not applicable in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Required Actions of Condition E are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not a sufficient reason to require a reactor shutdown .
(continued)
DAEC                          B 3.7-28                                    TSGR 068
 
CBC System B 3.7.5 BASES ACTIONS      E.1. E.2. and E.d    continued) or During movem t o irradiated fuel assemblies in the secondary containment, uring CORE ALTERATIONS, or during OPDRVs, if Required Actions B.1 and B.2 cannot be met within the required Completion Times, action must be taken to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the control building. This places the unit in a condition that minimizes risk.
If applicable, CORE ALTERATIONS and handling of irradiated fuel in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Affio.;
if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release . Actions must continue until the OPDRVs are suspended .
SURVEILLANCE SR 3.7.5.1 REQUIREMENTS This SR verifies that the heat removal capability of the system is sufficient to remove available control building heat load. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program. The Frequency is appropriate since 1
significant degradation of the CBC System is not expected over this time period.
REFERENCES  1.      UFSAR, Section 9.4.4.2.
DAEC                          B 3.7-29                                    TSGR 120
 
AC Sources - Shutdown B 3.8.2 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.2 AC Sources - Shutdown BASES BACKGROUND          A description of the AC sources is provided in the Bases for LCO 3.8.1, "AC Sources - Operating."
APPLICABLE          The OPERABILITY of the minimum AC sources during MODES 4 SAFETY              and 5 and during movement of irradiated fuel assemblies in the ANALYSES            secondary containment ensures that:
: a. The facility can be maintained in the shutdown or refueling condition for extended periods;
: b.      Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
: c. Adequate AC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of tho vessel or a fuel handling accident.
In general, when the unit is shutdown the Technical Specifications requirements ensure that the unit has the capability to mitigate the consequences of postulated accidents. However, assuming a single failure and concurrent loss of all offsite or loss of all onsite power is not required. The rationale for this is based on the fact that many Design Basis Accidents (DBAs) that are analyzed in MODES 1, 2, and 3 have no specific analyses in MODES 4 and 5.
Worst case bounding events are deemed not credible in MODES 4 and 5 because the energy contained within the reactor pressure boundary, reactor coolant temperature and pressure, and corresponding stresses result in the probabilities of occurrences significantly reduced or eliminated, and minimal consequences. These deviations from OBA analysis assumptions and design requirements during shutdown conditions are allowed by the LCO for required systems.
During MODES 1, 2, and 3, various deviations from the analysis assumptions and design requirements are allowed within the (continued)
DAEC                                B 3.8-26                              Alflendlflont 22a
 
AC Sources -    Shutdown B 3.8.2 BASES LCO          manner and to mitigate the consequences of postulated events (continued) during shutdown (e.g., fuel handling accidents and reactor vessel draindown). Automatic initiation of the required DG during shutdown conditions is specified in LCO 3.3.5.1, "eCCS Instrumentation," and LCO 3.3.8.1, "LOP Instrumentation".
The qualified offsite circuit(s) must be capable of maintaining rated frequency and voltage while connected to their respective essential bus( es), and of accepting required loads during an accident. Qualified offsite circuits are those that are described in the UFSAR and are part of the licensing basis for the unit. The required offsite circuit consists of either: 1) the incoming autotransformer (T1) and disconnect (1401, 6782, 2812 or 4731 ),
the incoming circuit breaker (8490) and disconnect (8491 ), the underground 34.5 kV line, the standby transformer (1X4), the 4160 volt supply line and one of the two supply circuit breakers (1A301 or 1A401) to essential buses 1A3 or 1A4, respectively, or
: 2) the incoming circuit breaker (5550 or 5560) and disconnect (5551 or 5555, respectively), the overhead 161 kV line, the startup transformer (1 X3), one of the two 4160 volt supply lines and one of the two supply circuit breakers (1A302 or 1A402) to essential buses 1A3 or 1A4, respectively, if required by LCO 3.8.8.
The required DG must be capable of starting, accelerating to rated speed and voltage, connecting to its respective essential bus on detection of bus undervoltage, and accepting required loads. This sequence must be accomplished within 1O seconds. Each DG must also be capable of accepting required loads within the assumed loading sequence intervals, and must continue to operate until offsite power can be restored to the essential buses.
The necessary portions of Emergency Service Water are also required to provide appropriate cooling to each required DG.
Proper sequencing of loads, including non-essential load shedding capability, is a required function for DG OPERABILITY.
In addition, proper timed logic sequence operation, is an integral part of offsite circuit OPERABILITY since its inoperability could impact the ability to start and maintain energized loads required OPERABLE by LCO 3.8.8. No automatic transfer capability is required for offsite circuits to be considered OPERABLE during shutdown conditions.
(continued)
DAEC                          B 3.8-28                              P.mendment 223
 
AC Sources - Shutdown B 3.8.2 that provide core cooling are
_B_A_S_E_S____(c_o_n_ti_nu_e_d__)_ __ _ _ _---1available APPLICABILITY                    The AC sources are quired to be OPERABLE in MODES 4 and 5 and during m vement of irradiated fuel assemblies in the secondary contai        ent to provide assurance that:
: a.      Systems providing adequate ooolant inventory mal<0up are available for the irradiated fuel assemblies in tho coro in caso of an inadvortont draindown of tho roaster vossol ;
: b.      Systems needed to mitigate a fuel handling accident are available;
: c.      Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
: d.      Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
AC power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.1 .
ACTIONS                          LCO 3.0.3 is not applicable while in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Actions have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action . If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be sufficient reason to require a reactor shutdown.
An offsite circuit is considered inoperable if it is not available to supply power to either of the essential buses. If both essential 4.16 kV buses are required per LCO 3.8.8, one division with offsite power available may be capable of supporting sufficient required features to allow continuation of CORE AL TERATIONS, land fuel movement, and operations with a potential for draining tho reaotor vossol. By the allowance of the option to declare required (continued)
DAEC                                              B 3.8-29                              /\mendment 223
 
AC Sources -          Shutdown B 3.8.2 BASES (continued)
ACTIONS          A.1 (continued) features inoperable that are not powered from offsite power, appropriate restrictions can be implemented in accordance with the affected required feature(s) LCOs' ACTIONS .
Required features remaining powered from a qualified offsite power circuit, even if that circuit is considered inoperable because it is not powering other required features, are not declared inoperable by this Required Action . . ~
A .2.1, A.2.2, A.2 .3, ~ B.1,      B.2, f. 3. ~.4 With the required offsite circuit not available to either division, the option still exists to declare all affected required features inoperable per required Action A.1 . Since this option may involve undesired administrative efforts, the allowance for sufficiently conservative actions is made. With the required DG inoperable, the minimum required diversity of AC power sources is not available. It is, therefore , required to suspend CORE AL TERATIONS movement of irradiated fuel assemblies in the secondary conta        ent, and aotivities that 001:1 ld res1:1 lt in Suspension of these                shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to Immediately initiate action to restore the required AC sources and to continue this action until restoration is accomplished in order to provide the necessary AC power to the plant safety systems.
The Completion Time of Immediately is consistent with the required times for ACTIONS requiring prompt attention. The restoration of the required AC electrical power sources should be completed as quickly as possible in order to minimize the time (continued)
DAEC                                B 3.8-30                                        TSGR 026A
 
AC Sources -  Shutdown B 3.8.2 BASES ACTIONS      A.2 .1. A.2.2. A.2 .3. ~ B.1. B.2. B.3. and B.4 (continued) during which the plant safety systems may be without sufficient power. Pursuant to LCO 3.0.6, the Distribution System ACTIONS would not be entered even if all AC sources to it are inoperable, resulting in de-energization. Therefore, the Required Actions of Condition A have been modified by a Note to indicate that when Condition A is entered with no AC power to any required essential bus, ACTIONS for LCO 3.8.8 must be Immediately entered . This Note allows Condition A to provide requirements for the loss of the offsite circuit whether or not a division is de-energized. LCO 3.8.8 provides the appropriate restrictions for the situation involving a de-energized division.
SURVEILLANCE SR 3.8.2.1 REQUIREMENTS SR 3.8.2.1 requires the SRs from LCO 3.8.1 that are necessary for ensuring the OPERABILITY of the AC sources in other than MODES 1, 2, and 3. SR 3.8.1.8 Is not required to be met since only one offsite circuit is required to be OPERABLE. Refer to the corresponding Bases for LCO 3.8.1 for a discussion of each SR.
This SR Is modified by two Notes. The reason for Note 1 is to          {
preclude requiring the OPERABLE DG(s) from being paralleled with the offsite power network or otherwise rendered inoperable during the performance of SRs, and to preclude deenergizing a required 4160 Vessential bus or disconnecting a required offsite circuit during performance of SRs. With limited AC sources available, a single event could compromise both the required circuit and the DG. It is the intent that these SRs must still be capable of being met, but actual performance is not required during periods when the DG and offslte circuit is required to be OPERABLE.
Note 2 states that SR 3.8.1.13 is considered to be met without the ECCS initiation signals OPERABLE when the ECCS initiation signals are not required to be OPERABLE per Table 3.3.5.1-1.
This SR demonstrates the DG response to an ECCS signal (either alone or in conjunction with a loss-of-power signal). This is consistent with the ECCS instrumentation requirements of Table 3.3.5.1-1 that do not require the ECCS signals to be OPERABLE in MODES 4 and 5 when ECCS is not required to be OPERABLE per LGO 3.5.2, "EGGS Shutdown''.
REFERENCES    None.
DAEC                          B 3.8-31
 
DC Sources -    Shutdown B 3.8.5 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.5 DC Sources -    Shutdown BASES BACKGROUND          A description of the DC sources is provided in the Bases for LCO 3.8.4, "DC Sources - Operating."
APPLICABLE          The initial conditions of Design Basis Accident and transient            t.,....--
SAFETY              analyses in the UFSAR, Chapter 15 (Ref. 1), assume that                'I ANALYSES            Engineered Safety Feature Systems are OPERABLE. The 125 VDC Electrical Power System provides normal and emergency DC electrical power for the Diesel Generators (DGs), emergency auxiliaries, and control and switching during all MODES of operation and during movement of irradiated fuel assemblies in the Secondary Containment.
The OPERABILITY of the DC subsystems is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum DC electrical power sources during MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment ensures that:
: a.      The facility can be maintained in the shutdown or refueling condition for extended periods;
: b.      Sufficient instrumentation and control capability Is available for monitoring and maintaining the unit status; and
: c.      Adequate DC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindo&#xa5;m of the vessel or a fuel handling accident.
The DC sources satisfy Criterion 3 of 10 CFR 50.36(c)(2)(ii).
(continued)
DAEC                                  B 3.8-52                                TSGR 044/\
 
DC Sources -    Shutdown B 3.8.5 BASES (continued)
LCO              The DC electrical power subsystems - with: Division I and Division II 125 VDC subsystems each consisting of one 125 V battery, the associated battery charger or the swing battery charger and the corresponding control equipment and interconnecting cabling supply power to the associated distribution system; and, the 250 VDC subsystem consisting of the 250V battery, one of the two battery chargers and the corresponding control equipment and interconnecting cabling sufficient to provide electrical power to the outboard RHR-SDC suction isolation valve (M0-1909), are required to be OPERABLE to support required DC distribution subsystems required OPERABLE by LCO 3.8.8, "Distribution Systems -Shutdown." This requirement ensures the availability of sufficient DC electrical power sources to operate the unit in a safe manner and to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and inadvertent reactor vessel draindown).
APPLICABILITY    The DC electrical power sources required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that:
core cooling Required features to provide adeqblate coolant inventory mal~oblp are available fer the irradiated fblol assemblies in tho core in ease sf an inadvertent draindewn of the roaster vessel ;
: b.      Required features needed to mitigate a fuel handling accident are available;
: c.      Required features necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
: d.      Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
The DC electrical power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.4.
(continued)
DAEC                              B 3.8-53                              /\mendment 22a
 
DC Sources -    Shutdown B 3.8.5 BASES (continued)
ACTIONS          LCO 3.0.3 is not applicable while in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Actions have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action . If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be sufficient reason to require a reactor shutdown.                            ~
A.1. A.2.1, A.2.2, ~ and      A.2.4 If more than one DC distribution subsystem is required according to LCO 3.8.8, the DC electrical power subsystems remaining OPERABLE with one or more DC electrical power subsystems land inoperable may be capable of supporting sufficient requl[e~
features to allow continuation of CORE AL TERATIONS,:iniel movement, and operations with a potential for draining the reactor vessel. By allowance of the option to declare requ ired features Inoperable with associated DC electrical power subsystems inoperable, appropriate restrictions are implemented in accordance with the affected system LCOs' ACTIONS. However, In many instances, this option may Involve undesired administrative efforts. Therefore, the allowance for sufficiently conservative actions is made (i.e., to suspend CORE AL TERATION~ movement of irradiated fuel assemblies in the f.e0r:~~F:&#xa5;:!:fe:::). '~a1 se.1e re**lt i*
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required DC electrical power subsystems and to continue this action until restoration is accomplished in order to provide the necessary DC electrical power to the plant safety systems.
(continued)
DAEC                              B 3.8-54                            Amendment 22a
 
Distribution Systems -  Shutdown B 3.8.8 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.8 Distribution Systems -    Shutdown BASES BACKGROUND            A description of the AC and DC Electrical Power Distribution System is provided in the Bases for LCO 3.8.7, "Distribution Systems - Operating."
APPLICABLE            The initial conditions of Design Basis Accident and transient          v SAFETY                analyses in the UFSAR, Chapter 15 (Ref. 1), assume Engineered /f ANALYSES              Safety Feature (ESF) Systems are OPERABLE. The AC and DC Electrical Power Distribution Systems are designed to provide sufficient capacity, capability, redundancy, and reliability to ensure the availability of necessary power to ESF Systems so that the fuel, Reactor Coolant System, and containment design limits are not exceeded.
The OPERABILITY of the AC and DC Electrical Power Distribution System is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum AC and DC electrical power sources and associated power distribution subsystems during MODES 4 and 5, and during movement of irradiated fuel assemblies in the secondary containment ensures that:
: a.      The facility can be maintained in the shutdown or refueling condition for extended periods;
: b.      Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
: c.      Adequate power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of the vessel or a fuel handling accident.
The AC and DC electrical power distribution systems satisfy Criterion 3 of 1o CFR 50.36(c)(2)(ii).
(continued)
DAEC                                    B 3.8-74                                TSGR 044A
 
Distribution Systems - Shutdown B 3.8.8 BASES (continued)
LCO              Various combinations of subsystems, equipment, and components are required OPERABLE by other LCOs, depending on the specific plant condition. Implicit in those requirements is the required OPERABILITY of necessary support required features. This LCO explicitly requires energization of the portions of the Electrical Distribution System necessary to support OPERABILITY of Technical Specifications required systems, equipment, and components - both specifically addressed by their own LCO, and implicitly required by the definition of OPERABILITY. In addition, it is acceptable for required buses to be cross-tied during shutdown conditions, permitting a single source to supply multiple redundant buses, provided the source is capable of maintaining proper frequency (if required) and voltage.
Maintaining these portions of the Distribution System energized ensures the availability of sufficient power to operate the plant in a safe manner to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and inadvertent reactor vessel draindown).
APPLICABILITY    The AC and DC electrical power distribution subsystems required to be OPERABLE In MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that: ~that provide core cooling            I
: a.      Systems to prsvido adequate ooolant inventory mal<eup are available k>r tho irradiated fuel in tho core in case of an inadvertent draindown of the reaotor vessel;
: b.      Systems needed to mitigate a fuel handling accident are available;
: c.      Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
: d.      Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
(continued)
DAEC                              B 3.8-75                              /\mendment  22~
 
Distribution Systems -  Shutdown B 3.8.8 BASES (continued)
APPLICABILITY    The AC and DC electrical power distribution subsystem (continued)    requirements for MODES 1, 2, and 3 are covered in LCO 3.8.7.
ACTIONS          LCO 3.0.3 is not applicable while in MODE 4 or 5. However, since irradiated fuel assembly movement can occur in MODE 1, 2, or 3, the Actions have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in r
either case, inability to suspend movement of irradiated fuel assemblies would not be sufficient reason to require a reactor shutdown.
A.1. A.2.1. A.2.2. A.2.3. ~ and A.2.a and Although redundant required features may r ui e redundant Divisions of electrical power distribution su yst ms to be OPERABLE, one OPERABLE distributio subsy tern division may be capable of supporting sufficient requ d feat res to allow continuation of CORE AL TERATIONS; fuel mov ment.,..aM
                          .    .            .                                  . By allowing the option to declare required features ssociated with an inoperable distribution subsystem inoperable, a propriate restrictions are implemented in accordance wit the affected distribution subsystem LCO's Required Actions In many instances this option may involve undesired ad inistrative efforts.
Therefore, the allowance for sufficiently conse      tive actions is made, (i.e., to suspend CORE ALTERATIONS; movement of irradiated fuel assemblies in the secondary containment, and any activities that could result in inadvertent draining of tho reactor vessel).
(continued)
DAEC                              B 3.8-76                                    TSGR 005
 
Distribution Systems -    Shutdown B 3.8.8 BASES (continued)                                          ~
ACTIONS          A.1. A.2.1. A.2 .2. A.2.3. ~ and A.2.e (continued)
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition . These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required AC and DC electrical power distribution subsystems and to continue this action until restoration is accomplished in order to provide the necessary power to t e plant safety systems.
3 Not withstanding performance o        e above conservative Required Actions, a required Residual eat Removal-Shutdown Cooling (RHR-SDC) subsystem ma be inoperable. In this case, Required Actions A.2.1 through A.2.4 do not adequately address the concerns relating to coolant circulation and heat removal.
Pursuant to LCO 3.0.6, the RHR-SDC ACTIONS would not be entered. Therefore, Required Action A.2.e is provided to direct declaring RHR-SDC inoperable, which resdf\_s' in taking the appropriate RHR-SDC ACTIONS.                    "[]
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required distribution subsystems should be completed as quickly as possible in order to minimize the time the plant safety systems may be without power.
(continued)
DAEC                              B 3.8-77                                    TSGR 005
 
System Leakage and Hydrostatic Testing Operation B 3.10.1 In the unlikely event of any primary system leak that
_B_A_S_E_S_ ____, could result in draining the RPV, APPLICABLE              these requirements will conservatively limit radiation releases to SAFETY                  the environment.
ANALYSES (continued) depressu rize',;"'ta+H:AAt-HAa-:EAe~N-efSS~FEH:>eA~*>fifRG~~ms-Ee oporato. The capability of tho low prossuro coolant injection and RPV Water Inventory 1--__          eeooro spray subsystems, as required in MODE 4 by LCO 3.5.2, I
Control
...._~~~~~~----'
I  ~CCS                  Shutdovm ," would be more than adequate to keep the
                                ':;:,Gi9'FS-~9QEf9 under this low decay heat load condition. Small system leaks would be detected by leakage inspections before significant inventory loss occurred.
RPV water level above the TAF For the purposes of this test, the protection provided by normally required MODE 4 applicable LCOs, in addition to the secondary containment requirements required to be met by this Special Operations LCO, will ensure acceptable consequences during normal hydrostatic test conditions and during postulated accident conditions.
As described In LCO 3.0.7, compliance with Special Operations LCOs is optional, and therefore, no criteria of 10 CFR 50.36(c)(2)(ii) apply. Special Operations LCOs provide flexibility to perform certain operations by appropriately modifying requirements of other LCOs. A discussion of the criteria satisfied for the other LCOs is provided in their respective Bases.
LCO                      As described in LCO 3.0.7, compliance with this Special Operations LCO is optional. Operation at reactor coolant temperatures > 212&deg;F can be in accordance with Table 1.1-1 for MODE 3 operation without meeting this Special Operations LCO or its ACTIONS. This option may be required due to PIT limits, however, which require testing at temperatures> 212&deg;F, while some system leakage or hydrostatic testing may require the safety/relief valves to be gagged, preventing their OPERABILITY.
Additionally, even with required minimum reactor coolant temperature:::; 212&deg;F, RCS temperatures may drift above 212&deg;F during the performance of system leakage and hydrostatic testing or during subsequent control rod scram time testing, which is typically performed in conjunction with a system leakage or hydrostatic test. While this Special Operations LCO is provided for system leakage and hydrostatic testing, and for scram time testing initiated in conjunction with a system leakage or (continued)
DAEC                                        B 3.10-3                              TSCR 078}}

Latest revision as of 19:21, 8 January 2025

License Amendment Request (TSCR-168), Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control
ML17164A076
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 06/09/2017
From: Dean Curtland
NextEra Energy Duane Arnold
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NG-17-0093, TSCR-168
Download: ML17164A076 (219)


Text