{{#Wiki_filter:ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES FNP-2
{{#Wiki_filter:ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES FNP-2 1.
: 1.     Table 3.8-1, pg. 3/4 8-20 through 3/4 8-28D
Table 3.8-1, pg. 3/4 8-20 through 3/4 8-28D 2.
: 2.     Section 3/4.6.1.7, pg. 3/4 6 -10
Section 3/4.6.1.7, pg. 3/4 6 -10 3.
: 3.     Table 3.7-4b, pg 3/4 7-49 through 3/4 7-49bb e
Table 3.7-4b, pg 3/4 7-49 through 3/4 7-49bb e
l 8211290663 821124 PDR ADOCK 05000364 PDR
l 8211290663 821124 PDR ADOCK 05000364 PDR


TABLC 3.8-1 CONTAIN;;ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                       BACKUP PROTECTION **
TABLC 3.8-1 CONTAIN;;ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip     Response                                  Trip set        Response Setpoint      Time            Device Number          Point            Time                    System Davice Number                                                                            (Ampere)        (Sec/ Cycles)              Powered 4
Trip
i and Location                      (Ampere)  (Sec/ Cycles)        and Location
: 1. 4160VAC Switchgears (NOTE: Response includes relay initiation time & breaker clearing time.)
18480            .39/9.2      Reactor Coolant Pump 2A DA04                    10560      .09/5.4            DA01 Reactor Coolant Pump 2B D803                    10560      .09/5.4            0B01                  16500            39/9.2 15310            .39/9.2      Reactor Coolant Pump 2C DC03                    10560      .09/5.4            DC04
: 2. 600VAC Load Centers EA04                    2750        .18/11              EPPC-2A    CP-1      MSCP Type X        N/A        Reactor Polar Crane i                                                                                                                          Containment Cooler 2A (Normal)
EA10                    1980        .10/6              EPPC-2A    CP-2      MSCP Type X        N/A i
E805                    1980        .10/6                EPPC-2A  CP-6      MSCP Type X        N/A        Containment Cooler 28 (Normal)
EB06                    1980        .10/6              EPPC-2E    CP-2      MSCP Type X        N/A        Containment Cooler 2C (Normal)
EC12                      1980        .10/6              EPPC-2D  CP-1      MSCP Type X        N/A        Containment Cooler 2D (Normal) 1320        .10/6              EPPC-2A    CP-3      MSCP Type X        N/A        CRDM Cooler Fan 2A ED11 1650        .10/6              EPPC-2A  CP-4      MSCP Type X        N/A        Containment Cooler 2A ED15                                                                                                        (Emergency) 1650        .10/6              EPPC-2A  CP-5      MSCP Type X        N/A      Containment Cooler 2B ED16                                                                                                        (Emergency) 1650        .10/6              EPPC-2D  CP-2      MSCP Type X        N/A      Containment Cooler 2C EE08                                                                                                          (Emergency) l 1320        .10/6              EPPC-2D  CP-3        MSCP Type X        N/A      CRDM Cooler Fan 28 EE13 1650        .10/6              EPPC-2D  CP-4        MSCP Type X        N/A      Containment Cooler 2D EE16                                                                                                          (Emergency)
: 3. 600VAC Motor Control Centers EPPC-28    CP-1      MSCP Type S        N/A      Reactor Cavity C1g Fan Mtr.
FA-F7                    231        .012/.72                                                                Reactor Cavity Cool Fan Mov FA-16                      11        012/.72          EPPC-2B    CP-2      MSCP Type S        N/A EPPC-2B    CP-3      MSCP Type S        N/A        CTMT Post LOCA Air Mixing FA-15                    116        .012/.72                                                              Fan 2D EPPC-2B    CP-4      MSCP Type S        N/A        CTMT Post LOCA Air Mixing FA-J5                    116        .012/.72                                                              fan 2C FARLEY - UNIT 2                                                  3/4 8-20 i


TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                         BACKUP PROTECTION **
===Response===
Trip   Response                                   Trip set         Response Setpoint       Time           Device Number             Point           Time                     System Device Number                                                                        (Ampere)     (Sec/ Cycles)                 Powered and Location                   (Ampere) (Sec/ Cycles)       and Location.
Trip set
EPPC-2F     CP-1         MSCP Type S       N/A       CTMT Post LOCA Air Mixing FB-13                  116       012/ 72 Fan 2B CP-2         MSCP Type S       N/A       CTMT Post LOCA Air Mixing FB-!4                  116      .012/.72          EPPC-2F Fan 2A 770         012/.72         EPPC-2G     CP-1         MSCP Type S       N/A       CTMT G1B Crane (N2T31K005-N)
 
FD-H7R                                                                                                  Reactor Cavity Cig Fan Mtr.
===Response===
231       012/.72         EPPC-2F     CP-3         MSCP Type S       N/A FB-J7                                                                      MSCP Type S        N/A        CTMT Elevator No. 3 Control FB-A4R               770     .012/.72           EPPC-2F     CP-4 012/.72         EPPC-2C     CP-1/2       MSCP Type S       N/A       CTMT Dome Recire. Fan 2A FC-P3                116 012/.72         EPPC-2C     CP-3/4       MSCP Type S       N/A       CTMT Dome Recirc. Fan 2B FC-P4                116                                                                      ---      RCP Motor Space Heaters FC-!2*               770     .012/.72           -------    ------
Davice Number Setpoint Time Device Number Point Time System i
RCP BRG Oil Lif t Pump 138      .012/.72           EPPC-2C     CP-5         MSCP Type S         N/A FC-14                                                                    MSCP Type S                  RCP BRG 011 Lift Pump 138         012/.72         EPPC-2C     CP-6                             N/A FC-N3                                                                                        ---      Refueling Wtr Surf ace Supply FC-J3*               232         012/.72         -------    ------      - ------- -
and Location (Ampere)
                                                                                        ----- -----        ---      Refueling Wtr Surface Exhaust FC-M5*               693         012/.72         -------    ------
(Sec/ Cycles) and Location (Ampere)
CTMT Pre-Access Fan Motors 363         012/.72         EPPC-2C     CP-7         MSCP Type S         N/A FC-J5                                                                    -----------        ---      RCP Mtr Space Heaters 2C FC-N4*               770         012/.72         -------    ------
(Sec/ Cycles)
                                                                                        -----------        ---      Receptacles Term. Box 2A FC-J6Li             1100         012/.72         ----- -    --- --
Powered 4
                                                                                        -----------        ---      Reactor Cavity Filter Pmp FC-J6R*             770       .012/.72         -------    --- --
1.
Recep.
4160VAC Switchgears (NOTE: Response includes relay initiation time & breaker clearing time.)
                                                                                                            ---      Up Ending Frame Winch str FC-S3L*             770       .012/.72         ----- -    --- --      -----------
DA04 10560
CTMT GIB Crane (N2T31K004-N) 770         012/.72         EPPC-2C     CP-8         MSCP Type S         N/A FC-M4L                                                                                        ---      Reactor Cavity Manipulator FC-N2L*             770       .012/.72         -------    ------        --------- -
.09/5.4 DA01 18480
Crane 770         012/.72         EPPC-2C     CP-9         MSCP Type $         N/A     CTMT GIB Crane (N2T31K006-N)
.39/9.2 Reactor Coolant Pump 2A D803 10560
FC-53R                                                                    -----------        ---      SW Port Drain Pump Recept.
.09/5.4 0B01 16500 39/9.2 Reactor Coolant Pump 2B DC03 10560
FC-C5R*             770       .012/.72           -------    ------
.09/5.4 DC04 15310
RCP BRG 011 Lift Pump 138      .012/.72         EPPC-2G     CP-2         MSCP Type S         N/A FD-D6                                                                                                    CTMT Dome Recirculation 116     .012/ 72           EPPC-2G     CP-3/4       MSCP Type S         N/A FD-E3                                                                                                    Fan 2D 363     .012/.72           EPPC-2G     CP-5         MSCP Type S         N/A       Reactor Cool Drain Tank FD-84                                                                                                    Pump 2B CP-6         MSCP Type S         N/A       CTMT Sump Pump Mtr 2A FD-C2                138      .012/.72          EPPC-2G CTMT Sump Pump Mtr 28 138       012/.72         EPPC-2G     CP-7         MSCP Type S         N/A FD-D2                                                                                                    CTMT Pre-Access Fan Mtrs 363       .012/.72         EPPC-2G     CP-8         MSCP Type S         N/A FD-C4                                                                                          ---      RCP Mtr Space Heaters 2B FO-G3*               770       012/.72         -------    ----        -----------
.39/9.2 Reactor Coolant Pump 2C 2.
Receptacles Term Box 2C FD-A3Li             1100       .012/.72         -------    ----          -----------        ---
600VAC Load Centers i
3/4 8-21 FARLEY - UNIT 2
EA04 2750
.18/11 EPPC-2A CP-1 MSCP Type X N/A Reactor Polar Crane i
EA10 1980
.10/6 EPPC-2A CP-2 MSCP Type X N/A Containment Cooler 2A (Normal)
E805 1980
.10/6 EPPC-2A CP-6 MSCP Type X N/A Containment Cooler 28 (Normal)
EB06 1980
.10/6 EPPC-2E CP-2 MSCP Type X N/A Containment Cooler 2C (Normal)
EC12 1980
.10/6 EPPC-2D CP-1 MSCP Type X N/A Containment Cooler 2D (Normal)
ED11 1320
.10/6 EPPC-2A CP-3 MSCP Type X N/A CRDM Cooler Fan 2A ED15 1650
.10/6 EPPC-2A CP-4 MSCP Type X N/A Containment Cooler 2A (Emergency)
ED16 1650
.10/6 EPPC-2A CP-5 MSCP Type X N/A Containment Cooler 2B (Emergency)
EE08 1650
.10/6 EPPC-2D CP-2 MSCP Type X N/A Containment Cooler 2C (Emergency)
EE13 1320
.10/6 EPPC-2D CP-3 MSCP Type X N/A CRDM Cooler Fan 28 l
EE16 1650
.10/6 EPPC-2D CP-4 MSCP Type X N/A Containment Cooler 2D (Emergency) 3.
600VAC Motor Control Centers FA-F7 231
.012/.72 EPPC-28 CP-1 MSCP Type S N/A Reactor Cavity C1g Fan Mtr.
FA-16 11 012/.72 EPPC-2B CP-2 MSCP Type S N/A Reactor Cavity Cool Fan Mov FA-15 116
.012/.72 EPPC-2B CP-3 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2D FA-J5 116
.012/.72 EPPC-2B CP-4 MSCP Type S N/A CTMT Post LOCA Air Mixing fan 2C FARLEY - UNIT 2 3/4 8-20 i
 
TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip
 
===Response===
Trip set
 
===Response===
Device Number Setpoint Time Device Number Point Time System and Location (Ampere)
(Sec/ Cycles) and Location.
(Ampere)
(Sec/ Cycles)
Powered FB-13 116 012/ 72 EPPC-2F CP-1 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2B FB-!4 116
.012/.72 EPPC-2F CP-2 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2A FD-H7R 770 012/.72 EPPC-2G CP-1 MSCP Type S N/A CTMT G1B Crane (N2T31K005-N)
FB-J7 231 012/.72 EPPC-2F CP-3 MSCP Type S N/A Reactor Cavity Cig Fan Mtr.
FB-A4R 770
.012/.72 EPPC-2F CP-4 MSCP Type S N/A CTMT Elevator No. 3 Control FC-P3 116 012/.72 EPPC-2C CP-1/2 MSCP Type S N/A CTMT Dome Recire. Fan 2A FC-P4 116 012/.72 EPPC-2C CP-3/4 MSCP Type S N/A CTMT Dome Recirc. Fan 2B RCP Motor Space Heaters FC-!2*
770
.012/.72 FC-14 138
.012/.72 EPPC-2C CP-5 MSCP Type S N/A RCP BRG Oil Lif t Pump FC-N3 138 012/.72 EPPC-2C CP-6 MSCP Type S N/A RCP BRG 011 Lift Pump Refueling Wtr Surf ace Supply FC-J3*
232 012/.72 Refueling Wtr Surface Exhaust FC-M5*
693 012/.72 FC-J5 363 012/.72 EPPC-2C CP-7 MSCP Type S N/A CTMT Pre-Access Fan Motors RCP Mtr Space Heaters 2C FC-N4*
770 012/.72 Receptacles Term. Box 2A FC-J6Li 1100 012/.72 Reactor Cavity Filter Pmp FC-J6R*
770
.012/.72 Recep.
Up Ending Frame Winch str FC-S3L*
770
.012/.72 FC-M4L 770 012/.72 EPPC-2C CP-8 MSCP Type S N/A CTMT GIB Crane (N2T31K004-N)
Reactor Cavity Manipulator FC-N2L*
770
.012/.72 Crane FC-53R 770 012/.72 EPPC-2C CP-9 MSCP Type $
N/A CTMT GIB Crane (N2T31K006-N)
SW Port Drain Pump Recept.
FC-C5R*
770
.012/.72 FD-D6 138
.012/.72 EPPC-2G CP-2 MSCP Type S N/A RCP BRG 011 Lift Pump FD-E3 116
.012/ 72 EPPC-2G CP-3/4 MSCP Type S N/A CTMT Dome Recirculation Fan 2D FD-84 363
.012/.72 EPPC-2G CP-5 MSCP Type S N/A Reactor Cool Drain Tank Pump 2B FD-C2 138
.012/.72 EPPC-2G CP-6 MSCP Type S N/A CTMT Sump Pump Mtr 2A FD-D2 138 012/.72 EPPC-2G CP-7 MSCP Type S N/A CTMT Sump Pump Mtr 28 FD-C4 363
.012/.72 EPPC-2G CP-8 MSCP Type S N/A CTMT Pre-Access Fan Mtrs RCP Mtr Space Heaters 2B FO-G3*
770 012/.72 Receptacles Term Box 2C FD-A3Li 1100
.012/.72 3/4 8-21 FARLEY - UNIT 2
 
TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMAkV PROTECTION BACKUP PROTECTION **
Trip


TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMAkV PROTECTION                                        BACKUP PROTECTION **
===Response===
Trip    Response                                  Trip set         Response Setpoint      Time          Device Number              Point            Time                    System Davice Number                                                                      (Ampere)                                    Powered and Location                  (Amperel  (Sec/ Cycles)      and Location                          (Sec / Cycl es.).
Trip set
FE-A6                363      .012/.72          EPPC-2G      CP-9      MSCP Type 5          M/A        Reactor Cool Drain Tank Pump 2A FE-A4Lt              1100      .012/.72          -------      ----      -----------        ---        Receptacles Term Box 2B FE-C3L              1100      .012/.72          EPPC-2G      CP-10    MSCP Type S          N/A        Incore Det. Drive & Cont. Pni.
FE-HS                116      .012/.72          EPPC-2G      CP-11/12 MSCP Type S          N/A        CTMT Dome Recirc. Fan 2C FU-G2                  32        012/.72        EPPC-28      CP-5      MSCP Type $          N/A        RHR Pumps Inlet Mov FU-H2                  13        012/.72        EPPC-28      CP-6      MSCP Type S        N/A        CTMT Air Cooling Fan Mov FU-H3                  13      .012/.72          EPPC-2B      CP-7      MSCP Type S        N/A        CTMT Air Cooling Fan Mov FU-H4                  11        012/.72        EPPC-2B      CP-8      MSCP Type S        N/A        RCP Motor Cooler Disch Mov FU-J4                  11        012/.72        EPPC-2B      CP-9      MSCP Type S        N/A        CTMT To Atmos Diff Press Mov FU-K4                  25      .012/.72          EPPC-2B      CP-10      MSCP Type S        N/A        Pressurizer to Relief Tank MOV FU-K6                  11      .012/.72          EPPC-2B      CP-11      MSCP Type S        N/A        CTMT Cooler Disch MOV CP-12      MSCP Type S        N/A        Post ACDT Air Sampler From FU-L4                  13      .012/.72          EPPC-2B CTMT Mov FU-L5                  13      .012/.72          EPPC-2B      CP-13      MSCP Type S        N/A        Post ACDT Air Sampler From CTMT Mov FU-T4                  25      .012/.72          EPPC-2B      CP-14      MSCP Type S          N/A        RCP Seal Water Return Isol.
FU-M4                  13      .012/.72          EPPC-28      CP-15      MSCP Type S          N/A        Post ACDT Air Sampler Return Mov FU-RS                  18      .012/.72          EPPC-2B      CP-16      MSCP Type S          N/A        CTMT Air Sampler Mov.
FU-V4                  13      .012/.72          EPPC-2B      CP-17      MSCP Type S          N/A        CRDM Cool Fan Damprs Mov.
FU-W2                  18      .012/.72          EPPC-28      CP-18      MSCP Type S          N/A        CTMT Air Cooler Disch Mov.
FU-W4                  32      .012/.72          EPPC-2B      CP-19      MSCP Type S          N/A        Reactor Cavity H2 Dilution Fan VLV 2A FU-T5                  50        .012/.72        EPPC-2B      CP-20      MSCP Type S          N/A        RHR System Inlet Isoi. V1v.
FU-Z2                523        012/.72        Q2R188032-A              1100            012/.72      Accumulator 2A Disch. Viv.
FU-23                523      .012/.72          Q2R18B031-A              1100            .012/.72      Accumulator 2C Disch. V1v.
FV-M3                  13        012/.72          EPPC-2F      CP-5      MSCP Type S          N/A        Post ACDT Air Sampler Return Mov.
FV-H4                  13      .012/.72          EPPC-2F      CP-6        MSCP Type S        N/A        Post ACDT Air Sampler From CTMT Mov FV-HS                  13      .012/.72          EPPC-2F      CP-7        MSCP Type S        N/A        Post ACDT Air Sampler From CTMT Mov FARLEY - UNIT 2                                              3/4 8-22


TABLE 3.8-1 CONTAIN TENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                                               BACKUP PROTECTION **
===Response===
W Trip             Response                                         Trip set       Response Setpoint                           Time             Device Number           Point           Time                   System Device Number                                                                                                                          (Sec/ Cycles)                Powered and Location                                   (Ampere)         (Sec/ Cycles)                     and Location         { Ampere)
Davice Number Setpoint Time Device Number Point Time System and Location (Amperel (Sec/ Cycles) and Location (Ampere)
FV-Y4                             13                       012/.72             EPPC-2F   CP-8       MSCP Type S         N/A       Post LOCA CTMT Vent Mov FV-YS                           32                   .012/.72                 EPPC-2F   CP-9       MSCP Type S         N/A       Instr. Air Line Disch. Mov.
(Sec / Cycl es.).
CP-10       MSCP Type S       N/A       CRDM Cool Fan Damper FV-12                            13                  .012/.72                EPPC-2F FV-J4                           18                 .012/.72                 EPPC-2F   CP-11     MSCP Type S         N/A       CTMT Air Cooler Disch. Mov.
Powered FE-A6 363
FV-J5                           18                   .012/.72               EPPC-2F   CP-12       MSCP Type S       N/A       CTMT Air Cooler Disch. Mov.
.012/.72 EPPC-2G CP-9 MSCP Type 5 M/A Reactor Cool Drain Tank Pump 2A Receptacles Term Box 2B FE-A4Lt 1100
FV-N2                           32                       012/.72             EPPC-2F   CP-13       MSCP Type S       N/A       Reac. Cavity H2 Dilution Fan Viv. 2B FV-52                         523                   .012/.72               Q2R188035-B           1100           .012/.72     Accumulator 18 Disch. Viv.
.012/.72 FE-C3L 1100
FV-V3                           50                   .012/.72               EPPC-2F   CP-14       MSCP Type S         N/A     RHR System Inlet 1s01. V1v.
.012/.72 EPPC-2G CP-10 MSCP Type S N/A Incore Det. Drive & Cont. Pni.
FV-W4                           25                       012/.72           EPPC-2F   CP-15       MSCP Type S       N/A       Pressurizer to Relief Isol.
FE-HS 116
.012/.72 EPPC-2G CP-11/12 MSCP Type S N/A CTMT Dome Recirc. Fan 2C FU-G2 32 012/.72 EPPC-28 CP-5 MSCP Type $
N/A RHR Pumps Inlet Mov FU-H2 13 012/.72 EPPC-28 CP-6 MSCP Type S N/A CTMT Air Cooling Fan Mov FU-H3 13
.012/.72 EPPC-2B CP-7 MSCP Type S N/A CTMT Air Cooling Fan Mov FU-H4 11 012/.72 EPPC-2B CP-8 MSCP Type S N/A RCP Motor Cooler Disch Mov FU-J4 11 012/.72 EPPC-2B CP-9 MSCP Type S N/A CTMT To Atmos Diff Press Mov FU-K4 25
.012/.72 EPPC-2B CP-10 MSCP Type S N/A Pressurizer to Relief Tank MOV FU-K6 11
.012/.72 EPPC-2B CP-11 MSCP Type S N/A CTMT Cooler Disch MOV FU-L4 13
.012/.72 EPPC-2B CP-12 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FU-L5 13
.012/.72 EPPC-2B CP-13 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FU-T4 25
.012/.72 EPPC-2B CP-14 MSCP Type S N/A RCP Seal Water Return Isol.
FU-M4 13
.012/.72 EPPC-28 CP-15 MSCP Type S N/A Post ACDT Air Sampler Return Mov FU-RS 18
.012/.72 EPPC-2B CP-16 MSCP Type S N/A CTMT Air Sampler Mov.
FU-V4 13
.012/.72 EPPC-2B CP-17 MSCP Type S N/A CRDM Cool Fan Damprs Mov.
FU-W2 18
.012/.72 EPPC-28 CP-18 MSCP Type S N/A CTMT Air Cooler Disch Mov.
FU-W4 32
.012/.72 EPPC-2B CP-19 MSCP Type S N/A Reactor Cavity H2 Dilution Fan VLV 2A FU-T5 50
.012/.72 EPPC-2B CP-20 MSCP Type S N/A RHR System Inlet Isoi. V1v.
FU-Z2 523 012/.72 Q2R188032-A 1100 012/.72 Accumulator 2A Disch. Viv.
FU-23 523
.012/.72 Q2R18B031-A 1100
.012/.72 Accumulator 2C Disch. V1v.
FV-M3 13 012/.72 EPPC-2F CP-5 MSCP Type S N/A Post ACDT Air Sampler Return Mov.
FV-H4 13
.012/.72 EPPC-2F CP-6 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FV-HS 13
.012/.72 EPPC-2F CP-7 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FARLEY - UNIT 2 3/4 8-22
 
TABLE 3.8-1 CONTAIN TENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
W Trip
 
===Response===
Trip set
 
===Response===
Device Number Setpoint Time Device Number Point Time System and Location (Ampere)
(Sec/ Cycles) and Location
{ Ampere)
(Sec/ Cycles)
Powered FV-Y4 13 012/.72 EPPC-2F CP-8 MSCP Type S N/A Post LOCA CTMT Vent Mov FV-YS 32
.012/.72 EPPC-2F CP-9 MSCP Type S N/A Instr. Air Line Disch. Mov.
FV-12 13
.012/.72 EPPC-2F CP-10 MSCP Type S N/A CRDM Cool Fan Damper FV-J4 18
.012/.72 EPPC-2F CP-11 MSCP Type S N/A CTMT Air Cooler Disch. Mov.
FV-J5 18
.012/.72 EPPC-2F CP-12 MSCP Type S N/A CTMT Air Cooler Disch. Mov.
FV-N2 32 012/.72 EPPC-2F CP-13 MSCP Type S N/A Reac. Cavity H2 Dilution Fan Viv. 2B FV-52 523
.012/.72 Q2R188035-B 1100
.012/.72 Accumulator 18 Disch. Viv.
FV-V3 50
.012/.72 EPPC-2F CP-14 MSCP Type S N/A RHR System Inlet 1s01. V1v.
FV-W4 25 012/.72 EPPC-2F CP-15 MSCP Type S N/A Pressurizer to Relief Isol.
Mov.
Mov.
50                   .012/.72               EPPC-2F   CP-16       MSCP Type S         N/A     RHR System Outlet Isol. Viv.
FV-V2 50
FV-V2                                                                                                                            RCP CCW Return from 011 Clr FV-C3                           25                   .012/.72               EPPC-2F   CP-17       MSCP Type S         N/A CP-IP       MSCP Type S         N/A     CTMT Air Cooling Fan Mov.
.012/.72 EPPC-2F CP-16 MSCP Type S N/A RHR System Outlet Isol. Viv.
FV-F2                            13                   .012/.72               EPPC-2F CTMT Air Coo 11ag Fan MOV.
FV-C3 25
FV-F3                            13                    .012/.72             EPPC-2F    CP-19      MSCP Type S        N/A EPPC-2F   CP-21       MSCP Type S         N/A     Reactor Cav Cooling Fan MOV.
.012/.72 EPPC-2F CP-17 MSCP Type S N/A RCP CCW Return from 011 Clr FV-F2 13
FB-02                            50                    .012/.72 4   208 VAC Motor Control Centers HA-03                         116                         012/.72           EPPC-2B   CP-23       MSCP Type N         N/A     Reac. Cavity H2 Dilution Fan 2A HB-N7                           116                       012/.72           EPPC-2F   CP-23       MSCP Type N         N/A     Reac. Cavity H2 Dilution Fan 2B 1100                         012/.72             Rod Pos. Ind         2000           .015/ 9     Digital Rod Position Control HB-L7R/HD-N6L                                                                                                                      and Indication (40ABKR) Distr.
.012/.72 EPPC-2F CP-IP MSCP Type S N/A CTMT Air Cooling Fan Mov.
Pnl.
FV-F3 13
: 5. 600VAC Pressurizer Distr. Pn1 2A                           '
.012/.72 EPPC-2F CP-19 MSCP Type S N/A CTMT Air Coo 11ag Fan MOV.
Circuit Bkrs.
FB-02 50
BKR #1                       1760                       .316/1' BKR #2                       1750                         016/1                                                                   Pressurizer Htr Group 2A BKR #3                       1760                       .016/1               EA-11                 3300           .18/11 BKR #4                       1760                       .016/1     t Terminal Box N2TB010 BKR #5                      1760
.012/.72 EPPC-2F CP-21 MSCP Type S N/A Reactor Cav Cooling Fan MOV.
                                                                                                                  .016/1]
4 208 VAC Motor Control Centers HA-03 116 012/.72 EPPC-2B CP-23 MSCP Type N N/A Reac. Cavity H2 Dilution Fan 2A HB-N7 116 012/.72 EPPC-2F CP-23 MSCP Type N N/A Reac. Cavity H2 Dilution Fan 2B HB-L7R/HD-N6L 1100 012/.72 Rod Pos. Ind 2000
                                                                                                                      \
.015/ 9 Digital Rod Position Control (40ABKR) Distr.
and Indication Pnl.
5.
600VAC Pressurizer Distr. Pn1 2A Circuit Bkrs.
BKR #1 1760
.316/1' BKR #2 1750 016/1 BKR #3 1760
.016/1 EA-11 3300
.18/11 Pressurizer Htr Group 2A Terminal Box N2TB010 BKR #4 1760
.016/1 t
.016/1]
BKR #5 1760
\\
i g
i g
5 FARLEY - UNIT 2                                                                      ;
5 3/4 8-23 FARLEY - UNIT 2 J
3/4 8-23 J     -


                                                                                                                                ..\
..\\
                                                                                                                                                                                                                                                  .~..
. ~..
c
(
(                t j
c t
                                            \,,                   -;                          [.Y,
\\,,
                '3   \
[.Y, j
                                    }*         I      -
N}-
                                                                        '                                                            1               T_ABLE 3.8 1 N}-                -
'3
e                         t. 1 A
}*
s   '
1 T_ABLE 3.8 1 1
                                                                        's      \
\\
f' i           ' gNTAtleMENT PENETRATION CONDUCTC,R
I e
                                                                                                                                                                                                                                            ~
t.
U      'N { - ,f {
's
                                                                                                                                                                                                                                                                                                    't uvERCURRENT PROTECTIVE DEVICLS                                                                                                                               '
\\
                                                                                                                                                                                                                                                    \
f' i
' gNTAtleMENT PENETRATION CONDUCTC,R
~
'N { -,f {
't A
s uvERCURRENT PROTECTIVE DEVICLS U
\\
BT,CKUP PROTECTION **
BT,CKUP PROTECTION **
* O            . _N_                                                                                                                                                                                -
P21 MARY P40 TECTI'N _(y x' Response Trip set
P21 MARY                                   P40x' TECTI'N                              .N _(y


===Response===
===Response===
Trip set                          Response Trip                      -
O
System Device Number                          ;      Point                              Time                9gg
. _N_
        ' Device Number                                           Setpoint_ i                             .i {ime s
.N Trip
Qmpere)                       (Sec/ Cycles)s K                             ) Poweref (Ampere)                             ylde/ Cycles), 's and Location _                                                 t.                               s                          N, m' a_nd Location                                                                                - -                                        -
' Device Number Setpoint_ i
                                                                                                                                                                                            ,                                            1 cx t.
.i {ime Device Number Point Time 9gg System Qmpere)
                                                                                                                                                                                                                                                                                  ')           1.g-g               ,
(Sec/ Cycles)s K
d ' 6. 600VAC Pressurizer
) Poweref s
                                                                                                                                ,              N                                                                                    N                          **        N--
a_nd Location (Ampere) ylde/ Cycles),
3; N                                                         ~"               '
's and Location _
          's   N'f,istr. Pn1 2B                                                     . , ' '                                      '
t.
                                                                                                                                                      ~
N, m' s
N - '!Cftcuit Bkrs.' %N                                                                (     ,3       -s
1
                                                                                                                                                                                                                    .s                                 's - )         M
')
                                                                                                                                                                                                                                                                      ,    J-          g(        '-
N--
1. g - g t.
d ' 6.
600VAC Pressurizer N
cx 3 ;
N N
~"
's N'f,istr. Pn1 2B
~
, J-g(
's M
N - '!Cftcuit Bkrs.' %
(
,3
- s
.s N ',
- )
s
s
                                                                                                                                                                                                                                                                                          -.)             ,
-.)
r                                         .
r
                ;x EKR #1                                         1/60                                         016/1                                                                                                                                       N s                         ,.
;x EKR #1
                                            *\                    D CO - - ,                                 010/1
*\\
                                                                                                                                                                      'N                           s 'N i                                       -
1/60 016/1 s
Pressbjzer Htr Croup b-7-            BKR #2 BKR #3
D CO - -,
                                              ,            s
010/1
                                                        ' N.174"                                             .G~df i                           ' EC-11
'N s 'N i N
                                                                                                                                                                          \1                     i300             K
Pressbjzer Htr Croup b-s BKR #3
                                                                                                                                                                                                                                    .18/11 Terminar geox N2TB011 016/1
' N.174"
                                                      ~\
.G~df i
                                                                                                                                                                            ,4) ,
' EC-11
BKR #4                                   J 7$ ,                                                                                  ,.
\\1 i300 K
                                                            \ t760                                             .016/1
.18/11 7-BKR #2 Terminar eox N2TB011
                                                                                                                                                                      -4,
~\\
                                                                                                                                                                                                        ~                              .              q SKR #5                                                     ,
J 7$,
;            7. 600VAC Pressurizer                                                                                                                                                                       ,
016/1
s                .       ,
,4),
                                                                                                                                                                                                                                                                                  . 'i       .(g H L'r. D t s t r '. Pn l 2C Circut; Bkrs.
~
                                                                                                                                                .' s.'
g BKR #4
                                                                                                                                                                                                .\        ,\
\\ t760
T
.016/1
                                                                                                                                                                                .s 3
-4, q
  '                                                                                                          .018/1.1 \                                 ,, k 3                            '
SKR #5 s
                                                                                                                                                                                                \ ,'          s PER #1                                   1540                                                                                 4 1     x                          I 4
7.
BKR #2                                   1540                                         018/1.1                                         s BKR #3                                   1940                                     .018/1.1                                                     (         .1         4400                             .18/11               Pressurizer Htr Group 2C -
600VAC Pressurizer
1540                                        018/1.1                            EF-04                  5 BKR #4                                                                                                                                        ',                                                                                Terminal Box N2TB008 BKR #4                                   1540                                       .018/1.1                                                                                         j BKR #5                                   1540                                   ( .018/1.1 018/1.1               -
.\\
'                          BKR #6 BXR #7 1540 1540                                      .018/1.1                                                                                       )I
,\\
: 8. 600VAC Pressurizer Htr. Distr. Pn1 2D Circuit Bkrs.
. 'i.(
BKR #1                                     1540                                     .018/1.1                                                                                                             .18/11                Pressurizer Htr Group 2D
H L'r. D t s t r '. Pn l 2C T
                                                                                                                .018/1.1                             EM-05                                         3300 BKR #2                                    1540                                                                                                                                                                                Terminal Box N2TB007 BKR #3                                     1540                                       018/1.1                                                   (
g Circut; Bkrs.
BKR #4                                     1540                                     .108/1.1                                                 s j
.' s.'
i FARLEY - UNIT 2                                                                                                                           3/4 8-24 i
,, k 3
.s
\\,'
3 s
PER #1 1540
.018/1.1 \\
I 4
BKR #2 1540 018/1.1 4
1 x
s BKR #3 1940
.018/1.1
(
.1 BKR #4 1540 018/1.1 EF-04 5
4400
.18/11 Pressurizer Htr Group 2C -
Terminal Box N2TB008 BKR #4 1540
.018/1.1 j
BKR #5 1540
(.018/1.1 BKR #6 1540 018/1.1
)I BXR #7 1540
.018/1.1 8.
600VAC Pressurizer Htr. Distr. Pn1 2D Circuit Bkrs.
BKR #1 1540
.018/1.1 BKR #2 1540
.018/1.1 EM-05 3300
.18/11 Pressurizer Htr Group 2D Terminal Box N2TB007 BKR #3 1540 018/1.1
(
BKR #4 1540
.108/1.1 j
s i
FARLEY - UNIT 2 3/4 8-24 i
i
i


TABLE 3.8-1 CONTAIN ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                                       BACKUP PROTECTION **
TABLE 3.8-1 CONTAIN ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip                   Response                                     Trip set             Response Device Number                     Setpoint                   Time               Device Number           Point                     Time                             System and Location                     (Ampere)                 (Sec/ Cycles)         and Location           (Ampere)             (Sec/ Cycles)                           Powered
Trip
: 9. 600VAC Pressurizer l       HTR. Distr. Pn1 2E Circuit Bkrs.
 
BKR #1                 1540                     .018/1.1 4
===Response===
BKR #2                 1540                       018/1.1 i               BKR #3                 1540                       018/1.1             EN-07 (Unit 1)         3300                   .18/11                 Pressurizer Htr Group 2E BKR #4                 1540                       018/1.1                                                                                   Terminal Box N2TB009 l             BKR #5                 1540                     .018/1.1 1                                                                                                                                                             .
Trip set
1     10. 125VDC Sol. Vivs.                                                                                           '
 
j         Power Fuses ,                                                        ,
===Response===
                                                .                                                                                                                o
Device Number Setpoint Time Device Number Point Time System and Location (Ampere)
  ,            FBI (TC-OSA)               3                       N/A         DC Dist Pn1 2A CKT fil       770                     012/.72               PRZR PWR Relief VLV (4454) 2A j               FBI (TC-254)               3                       N/A         at Dist Pn1 2D CKT #7         770                   .012/.72               PRZR PWR Relief VLV (444B) 28 FB5 (TC-06A)               3                       N/A         OC Dist.Pn1 2A CKT #17       770                   .012/.72               Letdown Line Isol. Viv. (459)
(Sec/ Cycles) and Location (Ampere)
FB5 (TC-06A)               3   ,                  N/A         DC.Ditt Pn1 2A CKT #17       770                     012/.72-           ' Letdown Line Isol. Viv. (460)
(Sec/ Cycles)
FB5 (TC-05A)               3                       N/A         DC Dist Pnl 2A CKT #11       770                   .C12/.72-               Reac. Cool Drn Tank Pump )
Powered 9.
600VAC Pressurizer l
HTR. Distr. Pn1 2E Circuit Bkrs.
BKR #1 1540
.018/1.1 BKR #2 1540 018/1.1 4
i BKR #3 1540 018/1.1 EN-07 (Unit 1) 3300
.18/11 Pressurizer Htr Group 2E BKR #4 1540 018/1.1 Terminal Box N2TB009 l
BKR #5 1540
.018/1.1 1
1 10.
125VDC Sol. Vivs.
j Power Fuses,
o FBI (TC-OSA) 3 N/A DC Dist Pn1 2A CKT fil 770 012/.72 PRZR PWR Relief VLV (4454) 2A j
FBI (TC-254) 3 N/A at Dist Pn1 2D CKT #7 770
.012/.72 PRZR PWR Relief VLV (444B) 28 FB5 (TC-06A) 3 N/A OC Dist.Pn1 2A CKT #17 770
.012/.72 Letdown Line Isol. Viv. (459)
FB5 (TC-06A) 3 N/A DC.Ditt Pn1 2A CKT #17 770 012/.72-
' Letdown Line Isol. Viv. (460)
FB5 (TC-05A) 3 N/A DC Dist Pnl 2A CKT #11 770
.C12/.72-Reac. Cool Drn Tank Pump )
Disch. Viv (100)
Disch. Viv (100)
FB6 (TC-05A)               3                       N/A         DC Dist Pn1 2A CKT #11       770                   .012/.72-               Reac. Cool Drn. Tank Venc Isol. Viv. (712)
FB6 (TC-05A) 3 N/A DC Dist Pn1 2A CKT #11 770
FB3 (TC-06A)               3                       N/A         DC Dist Pnl 2A CKT #17       770                   .012/.72               RMW to RCP Standpipe Fili       -
.012/.72-Reac. Cool Drn. Tank Venc Isol. Viv. (712)
                                                                                                                      ,                                      (8168C)                     --
FB3 (TC-06A) 3 N/A DC Dist Pnl 2A CKT #17 770
FB4 (TC-258)               3                       N/A         DC Dist Pn1 2D CKT #7         770     ~,            012/.72               PRZR Rel. Tnk to RMW 1s01.           l Viv. (8030)
.012/.72 RMW to RCP Standpipe Fili (8168C)
FB5 (TC 258)               3                       N/A         DC _Dist Pnt 2D CKT #7       770                   .012/.72               PRZR Rel. Tnk Drn to WPS Drn.
FB4 (TC-258) 3 N/A DC Dist Pn1 2D CKT #7 770 012/.72 PRZR Rel. Tnk to RMW 1s01.
~,
l Viv. (8030)
FB5 (TC 258) 3 N/A DC _Dist Pnt 2D CKT #7 770
.012/.72 PRZR Rel. Tnk Drn to WPS Drn.
Tek (8030)
Tek (8030)
FB6 (TC-278)               3                       N/A         DC
FB6 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770
                                                                                  ~
.012/.72 Excess Letdown Isol. Viv.
Dist Pn1 2D CKT #15     770                   .012/.72               Excess Letdown Isol. Viv.
~
(8153)
(8153)
FB5 (TC-278)               3                       N/A         DC Dist Pn1 20 CKT #18       770                     012/.72               RCS PRZR Aux. Spray V1v.
FB5 (TC-278) 3 N/A DC Dist Pn1 20 CKT #18 770 012/.72 RCS PRZR Aux. Spray V1v.
(8145) fB7 (TC-278)       .        3                       N/A         DC Dist Pnl 2D CKT #15       770                   .012/.72               " Excess Letdown Isol. Viv.
(8145) fB7 (TC-278) 3 N/A DC Dist Pnl 2D CKT #15 770
                                                                              ,                                                                              (8154) 4 e                           !~                                                                                                               -.
.012/.72
                                    /                                                                                     <
" Excess Letdown Isol. Viv.
(8154) 4 e
!~
/
0
0
                                              .w
.w
                                                  /                                                                                                               f' p.
/
                                                                                                          ~
f' p.
                                                                                                                                                      ~
FARLEY - UNIT'2 -
FARLEY - UNIT'2 -                                                               3/4 8-25                                                             ^
3/4 8-25
9                                                                                                                                                         ' eme(
~
nh,                                                                   ,      -                                 _",                                  ,  _Y
~
^
9
' eme(
nh, Y
 
m 4
TABLE 3.8-1 I
/
CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECT!vE DEVICES BACKUP PROTECTIGu **
PRIMARY PROTECTION Trip
 
===Response===
Trip set
 
===Response===
Device Number Setpoint Time Device Number Point Time System and Location (Amoere)
(Sec/ Cycles) and Location.
(Ampere)
(Sec/ Cycles)
Powered FB2 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770
.012/.72 RMW to RCP Standpipe Fill (8168A)
FB3 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770
.012/.72 RMW to RCP Standpipe Fill (81688)
Supply & Vent Isol.
Accum. N FB2 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 (8875A) 2Supply & Vent 1501.
Accum. N FB6 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 (8875C) 2 FB4 (TC-08A) 3 N/A DC Dist Pnl 2A CKT #13 770
.012/.72 Accum. Line Test 1501.
(8877A)
F08 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 Accum. Line Test Isol.
(8877C)
FB3 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 Accum. Fill Line Isol.
(8878A)
FB7 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770 012/.72 Accum Fill Line Isol (8878C)
FB5 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 Accum. Inject Test Line Isol. (88795)
FB9 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770
.012/.72 Accum. Inject. Test Line Isol. (8879C)
FB2 (TC-298) 3 N/A DC Dist Pnl 2D CKT #9 770 012/.7e Accum. N2 Supply & Vent Isol (8875B)
FB4 (TC-298) 3 N/A DC Dfst Pn1 2D CKT #9 770 012/.72 Accum. Test Line Isol.
(88778)
FB3 (TC-298) 3 N/A DC Dist Pn1 2D CKT #9 770 012/.72 Accum. Fill Line 1s01.
(88788)
FB5 (TC-298) 3 N/A DC Dist Pn1 2D CKT #9 770 012/.72 Accum. Inject. Test Line Isol (88798)
FBI (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 RCP Seal Leak Off 1s00 (1841A)
FBI (TC-298) 3 N/A DC Dist Pn1 2D CKT #8 770 012/.72 Damper Sol. Vivs. CTMT Purge Isol (3196)
FB9 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 Letdown Orifice Isol. Viv.
(81498) 3/4 8-26 FARLEY - UNIT 2
 
TABLE 3.8 1 CONTAINMENV PENEVRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip


m  _.
===Response===
4 TABLE 3.8-1 I
Trip set
                                                                                      /
CONTAINMENT PENETRATION CONDUCTOR                                    -
                  -                                      OVERCURRENT PROTECT!vE DEVICES                                                    ,
BACKUP PROTECTIGu **                            ,,
PRIMARY PROTECTION Trip set       Response Trip    Response                                                                            System Device Number          Point            Time Setpoint      Time                                                (Sec/ Cycles)
Powered Device Number                              (Sec/ Cycles)        and Location.        (Ampere) and Location                    (Amoere) 770          .012/.72    RMW to RCP Standpipe Fill 3          N/A        DC Dist Pn1 2D CKT #15 FB2 (TC-278)                                                                                            (8168A) 770          .012/.72    RMW to RCP Standpipe Fill 3            N/A      DC Dist Pn1 2D CKT #15 FB3 (TC-278)                                                                                            (81688) 770          .012/.72    Accum. N    Supply & Vent Isol.
N/A        DC Dist Pn1 2A CKT #13 FB2 (TC-08A)              3                                                                            (8875A) 2 770          .012/.72    Accum. N Supply & Vent 1501.
N/A        DC Dist Pn1 2A CKT #13 FB6 (TC-08A)                3                                                                          (8875C) 2 DC Dist Pnl 2A CKT #13      770          .012/.72  Accum. Line Test 1501.
3          N/A                                                              (8877A)
FB4 (TC-08A)
DC Dist Pn1 2A CKT #13      770          .012/.72  Accum. Line Test Isol.
3          N/A                                                              (8877C)
F08 (TC-08A)
DC Dist Pn1 2A CKT #13      770          .012/.72    Accum. Fill Line Isol.
3          N/A                                                              (8878A)
FB3 (TC-08A)
DC Dist Pn1 2A CKT #13      770            012/.72  Accum Fill Line FB7 (TC-08A)              3          N/A                                                              Isol (8878C) 770          .012/.72    Accum. Inject Test Line N/A        DC Dist Pn1 2A CKT #13 FB5 (TC-08A)              3                                                                            Isol. (88795) 770          .012/.72  Accum. Inject. Test Line N/A        DC Dist Pn1 2A CKT #13 FB9 (TC-08A)                3                                                                            Isol. (8879C) 770            012/.7e  Accum. N2 Supply & Vent N/A      DC Dist Pnl 2D CKT #9 FB2 (TC-298)                3                                                                            Isol (8875B)
DC Dfst Pn1 2D CKT #9        770            012/.72    Accum. Test Line Isol.
'                                        3          N/A                                                              (88778)
FB4 (TC-298)
DC Dist Pn1 2D CKT #9      770            012/.72    Accum. Fill Line 1s01.
3          N/A                                                              (88788)
FB3 (TC-298) 770            012/.72    Accum. Inject. Test Line N/A        DC Dist Pn1 2D CKT #9 FB5 (TC-298)                3                                                                            Isol (88798) 770            012/.72  RCP Seal Leak Off 1s00 3          N/A        DC Dist Pn1 2A CKT #17 FBI (TC-06A)                                                                                            (1841A) 770            012/.72  Damper Sol. Vivs. CTMT Purge 3          N/A        DC Dist Pn1 2D CKT #8                                  Isol (3196)
FBI (TC-298)
DC Dist Pn1 2A CKT #17      770            012/.72    Letdown Orifice Isol. Viv.
FB9 (TC-06A)                3          N/A                                                              (81498) 3/4 8-26 FARLEY - UNIT 2


TABLE 3.8 1 CONTAINMENV PENEVRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                                                  BACKUP PROTECTION **
===Response===
Trip                Response                                                Trip set        Response Setpoint                   Time           Device Number                         Point             Time                       System Deutce Number                                                                                                                  (Sec/ Cycles)                   Powered and Location                     (Ampere)           (Sec/ Cycles)        and Location                          (Ampere)
Deutce Number Setpoint Time Device Number Point Time System and Location (Ampere)
FB2 (TC-06A)                 3                   N/A     DC Dist Pn1 2A CKT #17                       770           .012/.72       RCP Seal Leak Off Isol.
(Sec/ Cycles) and Location (Ampere)
(Sec/ Cycles)
Powered FB2 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770
.012/.72 RCP Seal Leak Off Isol.
(8141C)
(8141C)
FBI (TC-278)                 3                   N/A     DC Dist Pn1 2D CKT #15                       770           .012/.72         RCP Seal Leak Off Isol.
FBI (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770
.012/.72 RCP Seal Leak Off Isol.
(8141B)
(8141B)
FBI (TC-06A)                 3                   N/A     DC Dist Pn1 2A CKT #18                       770           .012/.72         RCS Alternate Charging Line (8147)
FBI (TC-06A) 3 N/A DC Dist Pn1 2A CKT #18 770
N/A     DC Dist Pn1 2D CKT #14                       770             012/.72       RCS Normal Charging Line FBI (TC-278)                  3 (8146)
.012/.72 RCS Alternate Charging Line (8147)
FB7 (TC-25B)                 3                   N/A     DC Dist Pn1 2D CKT #7                       770             012/.72       Reac. Ves:e1 Leak Off Isol. (8032)
FBI (TC-278) 3 N/A DC Dist Pn1 2D CKT #14 770 012/.72 RCS Normal Charging Line (8146)
FB2 (TC-258)                 3                   N/A     DC Dist Pn1 2D CKT #7                       770           .012/.72         PRZR Rel. Tnk to RMW Supply Isol (4047) 3                   N/A     DC Dist Pn1 2D CKT #15                       770           .012/.72         RCP Seals Wtr By-pass FB8 (TC-27B) 1 sol. V1v. (8142)
FB7 (TC-25B) 3 N/A DC Dist Pn1 2D CKT #7 770 012/.72 Reac. Ves:e1 Leak Off Isol. (8032)
FB5 (TC-278)                 3                   N/A     DC Dist Pn1 2D CKT #15                       770             012/.72         Excess L'Down to VCT or RC l                                                                                                                                                   DrnTk (8143)
FB2 (TC-258) 3 N/A DC Dist Pn1 2D CKT #7 770
:          FB10 (TC-06a)                 3                   N/A     DC Dist Pn1 2A CKT #17                       770             012/.72         Letdown Orifice Isol. V1v.
.012/.72 PRZR Rel. Tnk to RMW Supply Isol (4047)
FB8 (TC-27B) 3 N/A DC Dist Pn1 2D CKT #15 770
.012/.72 RCP Seals Wtr By-pass 1 sol. V1v. (8142)
FB5 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770 012/.72 Excess L'Down to VCT or RC l
DrnTk (8143)
FB10 (TC-06a) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 Letdown Orifice Isol. V1v.
(8149A)
(8149A)
FB8 (TC-06A)                 3                     N/A     DC Dist Pn1 2A CKT #17                       770           .012/.72         Letdown Orifice Isol. V1v.
FB8 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770
l                                                                                                                                                   (8149C)
.012/.72 Letdown Orifice Isol. V1v.
FBI (TC-08A)                 3                     N/A     DC Dist Pn1 2A CKT #13                       770             012/.72         Accum. Test Line Isol. V1v.
l (8149C)
(8871) 3                     N/A     DC Dist Pn1 20 CKT #12                       770           .012/.72         RCP Comp. Cool (3184)
FBI (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770 012/.72 Accum. Test Line Isol. V1v.
FB4 (TC-318)
(8871)
FBI (TC-09A)                 3                     N/A     DC Dist Pn1 2A CKT #6                         770           .012/.72         Excess Letdown Hx Cool Disch.
FB4 (TC-318) 3 N/A DC Dist Pn1 20 CKT #12 770
.012/.72 RCP Comp. Cool (3184)
FBI (TC-09A) 3 N/A DC Dist Pn1 2A CKT #6 770
.012/.72 Excess Letdown Hx Cool Disch.
(3443)
(3443)
FAN (NBL27028-B)             3                     N/A     DC Dist Pn1 2E CKT #5                         770           .012/.72         SG2A Blowdown (3179C)
FAN (NBL27028-B) 3 N/A DC Dist Pn1 2E CKT #5 770
FAM (NBL27028-B)             3                     N/A     DC Dist Pn1 2E CKT #5                         770             012/.72         SG2B Blowdown (3180C)
.012/.72 SG2A Blowdown (3179C)
FAL (NBL27078-B)             3                     N/A     DC Dist Pn1 2E CKT #5                         770           .012/.72         SG2C Blowdown (3181C)
FAM (NBL27028-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 SG2B Blowdown (3180C)
FAC (NBL27028-B)             3                     N/A     DC Dist Pn12E CKT #5                         770           .012/.72 FAB NBL2702B-B               3                     N/A     DC Dist Pn1 2E LKT #5                         770           .012/.72         SG2A    Blowdown SG2B Blowdown   3952B (3951B)J FAA NBL27028-B               3                   N/A     DC Dist Pn12ii CKT #5                         770             012/.72         SG2C Blowdown 3953B)
FAL (NBL27078-B) 3 N/A DC Dist Pn1 2E CKT #5 770
FAD NBL2702B-B               3                     N/A     DC Dist Pn1 2E CKT #5                         770             012/.72         CVCS Letdown Line Viv.
.012/.72 SG2C Blowdown (3181C)
FAC (NBL27028-B) 3 N/A DC Dist Pn12E CKT #5 770
.012/.72 SG2A Blowdown (3951B)J FAB NBL2702B-B 3
N/A DC Dist Pn1 2E LKT #5 770
.012/.72 SG2B Blowdown 3952B FAA NBL27028-B 3
N/A DC Dist Pn12ii CKT #5 770 012/.72 SG2C Blowdown 3953B)
FAD NBL2702B-B 3
N/A DC Dist Pn1 2E CKT #5 770 012/.72 CVCS Letdown Line Viv.
(39508)
(39508)
FD (NBL2702A-A)             3                     N/A     DC Dist Pn1 2B CKT #5                         770           .012/.72         CVCS Letdown Line Viv.
FD (NBL2702A-A) 3 N/A DC Dist Pn1 2B CKT #5 770
.012/.72 CVCS Letdown Line Viv.
(3950A)
(3950A)
FARLEY - UNIT 2 1
FARLEY - UNIT 2 1


TABLE 3.8-1 CONTAINAENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES BACKUP PROTECTION **
TABLE 3.8-1 CONTAINAENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES BACKUP PROTECTION **
PRIMARY PROTECTION Trip set        Response Trip   Response                                                                         System Device humber         Point               Time Setpoint    Time                                              (Sec/ Cycles)               Powered D3vice Number                                (Sec/ Cycles)     and Location         (Ampere)
PRIMARY PROTECTION Trip
(Ampere) and Location OC Dist Pn128 CKT #5       770             012/.72     SG2A Blowdown (3951A) 3        N/A                                                  012/.72    SG2B Blowdown (3952A)
 
FC (NBL2702A-A)                         N/A       DC Dist Pn1 28 CKT #5     770 3                                                                          SG2C Blowdown (3953A)
===Response===
FB (NBL2702A-A)                         N/A       DC Dist Pnl 2B CKT #5     770             012/.72 3                                                                          SG2A Blowdown (7697A)
Trip set
FA (NBL2702A-A)                         N/A       DC Dist Pn1 28 CKT #5     770             012/.72 3                                                              012/.72    SG2B Blowdown (7698A FK (NBL2702A-A)                                   DC Dist Pol 2B CKT #5       770 FJ (NBL2702A-A)               3         N/A N/A      DC Dist Pnl 28 CKT #5       770           012/.72     SG2CBlowdown(1699A)i 3                                                              012/.72    SG2A Blowdown (7697BJ FH (NBL2707A-A)               3         N/A       DC Ofst Pn1 2E CKT #5     770 FAK (NBL27028-B)                                                            770             012/.72   SG2B Blowdown (76988) 3         N/A     DC Dist Pnl 2E CKT #5                                 SG2C Blowdown (76998)
 
FAJ (NBL27028-B)                                   DC Dist Pn1 2E CKT #5     770             012/.72 FAH (NBL2702B-B)             3         N/A 770             012/.72   Press. Stm Space Sampler 3         N/A       DC Dist Pnl 2E CKT #5 FAS (NBL2702B-B)                                                                                        (3880) 770               012/.72 Press. Liq Space Sampler 3         N/A       DC Dist Pn1 2E CKT #5 FAR (NBL2702B-B)                                                                                        (3881) 770               012/.72 Accumulator Sampler (3766) 3        N/A      DC Dist Pol 2C CKT #6                                SG2ABlowdownSampler(3179A[
===Response===
F/3766(NFSS2607A-A)                               DC Dist Pn1 2C CKT #6     770               012/.72 F/3179A(NFSS2607A A)         3         N/A 770               012/.72 SG2A Blowdown Sampler (31798J 3        N/A      DC Dist Pnl 2C CKT #6                                  SG2B Blowdown Sampler (3180Aj F/3179B(NFSS2607A-A)                             DC Dist Pn1 2C CKT #6     770               012/.72 F/3180A(NFSS2607A-A)         3         N/A 770               012/.72   SG2B Blowdown Sampler (31808) 3         N/A       DC Dist Pn1 2C CKT #6                                 SG2C Blowdown Sampler (3818AJ F/3180B(NFSS2607A-A)                             DC Dist Pn1 2C CKT #6       770               012/.72 F /3181 A(NF SS2607 A- A)    3        N/A 012/.72 SG2C Blowdown Sampler (3181B?
D3vice Number Setpoint Time Device humber Point Time System and Location (Ampere)
DC Dist Pnl 2C CKT #6      770 F/3181B(NFSS2607A-A)         3         N/A 770           .012/.72     Accum. Tank 2A Sampler (3162?
(Sec/ Cycles) and Location (Ampere)
3       N/A       DC Dist Pn1 2C CKT #6                                 Accum. Tank 2G Sampler (3163)
(Sec/ Cycles)
F/3162(NFSS2607A-A)                              DC Dist Pn1 2C CKT #6       770               012/.72 F/3163(NFSS2607A-A)            3        N/A 770              012/.72  Accum. Tank 2C Sampler (3164) 3         N/A     DC Dist Pnl 2C CKT #6                                  Reac. Coolant Hot Leg (3101)
Powered FC (NBL2702A-A) 3 N/A OC Dist Pn128 CKT #5 770 012/.72 SG2A Blowdown (3951A)
F/3164(NFSS2607A-A                               DC Dist Pnl 2F CKT #10     770               012/.72 F/3101(NFSS2607B-B            3        N/A 770          .012/.72     Reac. Coolant Hot Leg (3102) 3         N/A     DC Dist Pn1 2F CKT #10                                CTMT Sump Disch. (3376)
FB (NBL2702A-A) 3 N/A DC Dist Pn1 28 CKT #5 770 012/.72 SG2B Blowdown (3952A)
F/3102(NFSS26078-B                                DC Dist Pn1 2D CKT #16     770               012/.72 3        N/A                                                    012/.72  CTMTCoolerDrainsq3395A)
FA (NBL2702A-A) 3 N/A DC Dist Pnl 2B CKT #5 770 012/.72 SG2C Blowdown (3953A)
FA(NGB25040)                                     DC Dist Pn1 2G CKT #12     770 3        N/A                                                            CTMT Cooler Drains I 3395B)
FK (NBL2702A-A) 3 N/A DC Dist Pn1 28 CKT #5 770 012/.72 SG2A Blowdown (7697A)
!            FA(NGB25040)
SG2CBlowdown(1699A)i SG2B Blowdown (7698A FJ (NBL2702A-A) 3 N/A DC Dist Pol 2B CKT #5 770 012/.72 FH (NBL2707A-A) 3 N/A DC Dist Pnl 28 CKT #5 770 012/.72 FAK (NBL27028-B) 3 N/A DC Ofst Pn1 2E CKT #5 770 012/.72 SG2A Blowdown (7697BJ FAJ (NBL27028-B) 3 N/A DC Dist Pnl 2E CKT #5 770 012/.72 SG2B Blowdown (76988)
N/A     DC Dist Pn1 2G CKT #12     770           .012/.72 FD(NGB25040)                  3 770          .012/.72     CTMT Cooler Drains 3        N/A      DC Dist Pn1 2G CKT #12                                CTMT Cooler Drains   33950 ((3395C FC(NGB25040)                                     DC Dist Pnl 2G CKT #12     770           .012/.72 FB(NGB25040)                 3         N/A 770           .012/.72   PRZR Liquid Sampler (3103 3       N/A       DC Dist Pn1 2C CKT #6                                 PRZR Liquid Sampler (3104)
FAH (NBL2702B-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 SG2C Blowdown (76998)
F/3103(NFSS26078-B)                               DC Dist Pnl 2C CKT #6       770             012/.72 F/3104(NFSS26078-B)           3       N/A 770             .012/.72   Reac. Hot Leg Sampler (3765) 3        N/A      DC Dist Pn1 2C CKT #6 F/3765(NFSS2607B-B) l I
FAS (NBL2702B-B) 3 N/A DC Dist Pnl 2E CKT #5 770 012/.72 Press. Stm Space Sampler (3880)
FARLEY - UNIT 2                                                 3/4 8-28A
FAR (NBL2702B-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 Press. Liq Space Sampler (3881)
F/3766(NFSS2607A-A) 3 N/A DC Dist Pol 2C CKT #6 770 012/.72 Accumulator Sampler (3766)
F/3179A(NFSS2607A A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2ABlowdownSampler(3179A[
F/3179B(NFSS2607A-A) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 SG2A Blowdown Sampler (31798J F/3180A(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2B Blowdown Sampler (3180Aj F/3180B(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2B Blowdown Sampler (31808)
F /3181 A(NF SS2607 A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2C Blowdown Sampler (3818AJ F/3181B(NFSS2607A-A) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 SG2C Blowdown Sampler (3181B?
F/3162(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770
.012/.72 Accum. Tank 2A Sampler (3162?
F/3163(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 Accum. Tank 2G Sampler (3163)
F/3164(NFSS2607A-A 3
N/A DC Dist Pnl 2C CKT #6 770 012/.72 Accum. Tank 2C Sampler (3164)
F/3101(NFSS2607B-B 3
N/A DC Dist Pnl 2F CKT #10 770 012/.72 Reac. Coolant Hot Leg (3101)
F/3102(NFSS26078-B 3
N/A DC Dist Pn1 2F CKT #10 770
.012/.72 Reac. Coolant Hot Leg (3102)
FA(NGB25040) 3 N/A DC Dist Pn1 2D CKT #16 770 012/.72 CTMT Sump Disch. (3376)
FA(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770 012/.72 CTMTCoolerDrainsq3395A)
FD(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770
.012/.72 CTMT Cooler Drains I 3395B)
CTMT Cooler Drains ((3395C CTMT Cooler Drains FC(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770
.012/.72 33950 FB(NGB25040) 3 N/A DC Dist Pnl 2G CKT #12 770
.012/.72 F/3103(NFSS26078-B) 3 N/A DC Dist Pn1 2C CKT #6 770
.012/.72 PRZR Liquid Sampler (3103 F/3104(NFSS26078-B) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 PRZR Liquid Sampler (3104)
F/3765(NFSS2607B-B) 3 N/A DC Dist Pn1 2C CKT #6 770
.012/.72 Reac. Hot Leg Sampler (3765) l I
FARLEY - UNIT 2 3/4 8-28A
 
l TABLE 3.8 1 CONTAINMENT PrNETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip
 
===Response===
Trip set


l TABLE 3.8 1 CONTAINMENT PrNETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                            BACKUP PROTECTION **
===Response===
Trip    Response                                Trip set        Response Setpoint           Time             Device Number         Point                 Time                 System Davice Number                                                                                  (Ampere)     (Sec/ Cycles)                 Powered and Location                         (Ampere)         (Sec/ Cycles)       and Location
Davice Number Setpoint Time Device Number Point Time System and Location (Ampere)
: 11. 120VAC Sol. Vivs. Power Fuses 3         N/A         AC Dist Pn1 2J CKT #2   3000           .016/1           Reac. Cavity Cooling (3999A)
(Sec/ Cycles) and Location (Ampere)
FM(NGB2504M)                                                                                                        Reac. Cavity Cooling (39998)
(Sec/ Cycles)
FF(NGB25040)                         3         N/A         AC Dist Pn1 2K CKT #2   3000           .016/1
Powered 11.
: 12. Variable D.C.
120VAC Sol. Vivs. Power Fuses FM(NGB2504M) 3 N/A AC Dist Pn1 2J CKT #2 3000
Voltage CRDM Fuses (125 V Max) 10         N/A       RC Power Cas FU1/2/3       30                     N/A   Mechanism #1 Sta. Gripper FU13/A22                                                                                                             Group A 10         N/A       RC Power Cab FU1/2/3       30                     N/A   Mechanism #2 Sta. Gripper FU14/A22                                                                                                             Group A 10         N/A       RC Power Cab FU1/2/3       30                     N/A   Mechanism f3 Sta. Gripper FU15/A22                                                                                                             Group A 10         N/A       RC Power Cab FU1/2/3         30                     N/A   Mechanism #4 Sta. Gripper FU16/A22                                                                                                            Group A RC Power Cab FU4/5/6         30                     N/A   Mechanism #1 Sta. Gripper FU25/A23                           10         N/A Group B RC power Cab FU4/5/6         30                     N/A   Mechanism #2 Sta. Gripper FU26/A23                           10         N/A Group B 10          N/A        RC Power Cab FU4/5/6         30                     N/A   Mechanism #3 Sta. Gripper FU27/A23                                                                                                             Group B RC Power Cab FU4/5/6         30                     N/A   Mechanism #4 Sta. Gripper FU28/A23                            10          N/A Group B                     i 10         N/A       RC Power Cab FU7/8/9         30                     N/A   Mechanism #1 Sta. Gripper FU41/A24                                                                                                             Group C RC Power Cab FU7/8/9         30                     N/A   Mechanism #2 Sta. Gripper FU42/A24                           10          N/A Group C 10         N/A       RC Power Cab FU7/8/9         30                     N/A   Mechanism #3 Sta. Gripper FU43/A24                                                                                                           Group C RC Power Cab FU7/8/9         30                     N/A   Mechanism f4 Sta. Gripper FU44/A24                            10        N/A Group C FARLEY - UNIT 2                                                         3/4 8-288
.016/1 Reac. Cavity Cooling (3999A)
FF(NGB25040) 3 N/A AC Dist Pn1 2K CKT #2 3000
.016/1 Reac. Cavity Cooling (39998) 12.
Variable D.C.
Voltage CRDM Fuses (125 V Max)
FU13/A22 10 N/A RC Power Cas FU1/2/3 30 N/A Mechanism #1 Sta. Gripper Group A FU14/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism #2 Sta. Gripper Group A FU15/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism f3 Sta. Gripper Group A FU16/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism #4 Sta. Gripper Group A FU25/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #1 Sta. Gripper Group B FU26/A23 10 N/A RC power Cab FU4/5/6 30 N/A Mechanism #2 Sta. Gripper Group B FU27/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #3 Sta. Gripper Group B FU28/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #4 Sta. Gripper Group B i
FU41/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #1 Sta. Gripper Group C FU42/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #2 Sta. Gripper Group C FU43/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #3 Sta. Gripper Group C FU44/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism f4 Sta. Gripper Group C FARLEY - UNIT 2 3/4 8-288


VABLE 3.8-1 CONTAINMENV PENETRAVION CON 00CVOR OVERCURRENT PROTFCTIVE DEVICM PRIMARY PROTECTION                                   BACKUP PROTECTION **
VABLE 3.8-1 CONTAINMENV PENETRAVION CON 00CVOR OVERCURRENT PROTFCTIVE DEVICM PRIMARY PROTECTION BACKUP PROTECTION **
Trip     Response                               Trip set       Response Device Number                 Setpoint     Time             Device Number         Point           Time                   System and Location                 (Ampere) (Sec/ Cycles)       and Location         (Ampere)     (Sec/ Cycles)             Powered 50         N/A                                   150             N/A       Mechanism #1 Lift Group A FU1/A51 50         N/A                                   150             N/A       Mechanism #2 Lift  Group A FU2/A51                                                                                            Mechanism #3  Lift Group A F01/A52               50         N/A                                   150             N/A 50         N/A                                   150             N/A       Mechanism #4 Lift Group A FU2/A52 50         N/A                                   150             N/A       Mechanism #1 Lift Group B FU1/A53 FU2/A53               50         N/A       Fusible Olsconnect         150             N/A       Mechanism #2 Lift Group B 50         N/A       Bus Duct Plug-In           150             N/A       Mechanism #3 List Group B FU1/A54 50         N/A       Unit A-101                 150             N/A       Mechanism #4 List Group B FU2/A54                                                                                            Mechanism #1  Lift  Group C FU1/A55               50         N/A                                   150             N/A 50         N/A                                   150             N/A       Mechanism #2 Lift Group C FU2/A55 50         N/A                                   150             N/A       Mechanism f3 Lift Group C FU1/A56 50         N/A                                   150             N/A       Mechanism #4 Lift Group C FU2/A56 FU21/A25               10         N/A                                   30             N/A       Mechanism #1 Moving Gripper Group A FU22/A25               10         N/A                                   30             N/A       Mechanism #2 Moving Gripper Group A FU23/A25               10         N/A 30             N/A       Mechanism f 3 Moving Gripper Group A FU24/A25               10         N/A                                   30             N/A       Mechanism #4 Moving Gripper Group A FU33/A26               10         N/A                                   30             N/A       Mechanism #1 Moving Gripper Group B FU34/A26               10         N/A                                   30             N/A       Mechanism #2 Moving Gripper Group B FU35/A26               10         N/A       Fusible Disconnect           30             N/A       Mechanism #3 Moving Gripper Bus Duct Plug-In                                     Group B FU36/A26               10         N/A       Unit A-102                   30             N/A       Mechanism f 4 Moving Gripper Group B FU49/A27               10         N/A                                   30             N/A       Mechanism #1 Moving Gripper Group C FU50/A27               10           N/A                                   30             N/A       Mechanism #2 Moving Gripper Group C FU51/A27             10           N/A                                   30             N/A       Mechanism #3 Moving Gripper Group C FU52/A27             10           N/A                                   30             N/A       Mechanism #4 Moving Gripper Group C FARLEY - UNIT 2
Trip
 
===Response===
Trip set
 
===Response===
Device Number Setpoint Time Device Number Point Time System and Location (Ampere)
(Sec/ Cycles) and Location (Ampere)
(Sec/ Cycles)
Powered FU1/A51 50 N/A 150 N/A Mechanism #1 Lift Group A FU2/A51 50 N/A 150 N/A Mechanism #2 Lift Group A F01/A52 50 N/A 150 N/A Mechanism #3 Lift Group A FU2/A52 50 N/A 150 N/A Mechanism #4 Lift Group A FU1/A53 50 N/A 150 N/A Mechanism #1 Lift Group B FU2/A53 50 N/A Fusible Olsconnect 150 N/A Mechanism #2 Lift Group B FU1/A54 50 N/A Bus Duct Plug-In 150 N/A Mechanism #3 List Group B FU2/A54 50 N/A Unit A-101 150 N/A Mechanism #4 List Group B FU1/A55 50 N/A 150 N/A Mechanism #1 Lift Group C FU2/A55 50 N/A 150 N/A Mechanism #2 Lift Group C FU1/A56 50 N/A 150 N/A Mechanism f3 Lift Group C FU2/A56 50 N/A 150 N/A Mechanism #4 Lift Group C FU21/A25 10 N/A 30 N/A Mechanism #1 Moving Gripper Group A FU22/A25 10 N/A 30 N/A Mechanism #2 Moving Gripper Group A FU23/A25 10 N/A 30 N/A Mechanism f 3 Moving Gripper Group A FU24/A25 10 N/A 30 N/A Mechanism #4 Moving Gripper Group A FU33/A26 10 N/A 30 N/A Mechanism #1 Moving Gripper Group B FU34/A26 10 N/A 30 N/A Mechanism #2 Moving Gripper Group B FU35/A26 10 N/A Fusible Disconnect 30 N/A Mechanism #3 Moving Gripper Bus Duct Plug-In Group B FU36/A26 10 N/A Unit A-102 30 N/A Mechanism f 4 Moving Gripper Group B FU49/A27 10 N/A 30 N/A Mechanism #1 Moving Gripper Group C FU50/A27 10 N/A 30 N/A Mechanism #2 Moving Gripper Group C FU51/A27 10 N/A 30 N/A Mechanism #3 Moving Gripper Group C FU52/A27 10 N/A 30 N/A Mechanism #4 Moving Gripper Group C FARLEY - UNIT 2
[
[
t                                                                                                                                   __
t
 
TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **
Trip
 
===Response===
Trip set


TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION                                                BACKUP PROTECTION **                                          .
===Response===
Trip            Response                                  Trip set        Response Time             Device Number           Point             Time                 System Device Number                      Setpoint (Ampere)         (Sec/ Cycles)       and location           (Ampere)     (Sec/ Cycles)               Powered and Location
Device Number Setpoint Time Device Number Point Time System and Location (Ampere)
: 13. 480/277 VAC                                                                                                                                               ,
(Sec/ Cycles) and location (Ampere)
Lighting Cables 825             .012/.72           EB09                   3300           .1/6       Lighting Panel 2R(N2T51L001A)
(Sec/ Cycles)
LCP-2R N2T51 LOO 3A-N                                                                                              Lighting Panel 20(N2T51L001D LCP-20 N2T51 LOO 3D-N     825             .012/.72           EB09                   3300           .1/6 825             .012/.72           EC13                   3300           .1/6       Lighting Panel 2Q(N2T51L001B LCP-2Q N2751 LOO 38-N                                                                                              Lighting Panel 2P(N2T51 LOGIC LCP-2P N2T51 LOO 3C-N     825             .012/.72           EC13                   3300           .1/6
Powered 13.
                                                                                                                    ----        Receptacle Panel FE-C3Rf                 1100               .012/.72           ----                  ----
480/277 VAC Lighting Cables LCP-2R N2T51 LOO 3A-N 825
2.' "2T51 LOO 2A-N) 14   480 VAC 30. H2 Recombiner Power Supply FAL3L                   1100               .012/.72           ED10                   6600           .18/11     H2 Recombiner HTRS (Q2E17G001A-A)
.012/.72 EB09 3300
FB-H6R                   1100               .012/.72           EE10                   9900           .18/11     H2 Recombiner HTRS (Q2E17G0018-B) i i
.1/6 Lighting Panel 2R(N2T51L001A)
j
LCP-20 N2T51 LOO 3D-N 825
* Not required in modes 1-4
.012/.72 EB09 3300
      #  May be energized under administrative control when required for maintenance.
.1/6 Lighting Panel 20(N2T51L001D LCP-2Q N2751 LOO 38-N 825
    **  This portion of the table is not valid until after the second refueling outage except for the backup protection devices that have been installed prior to startup following the first refueling outage.
.012/.72 EC13 3300
FARLEY - UNIT 2                                                         3/4 8-28D
.1/6 Lighting Panel 2Q(N2T51L001B LCP-2P N2T51 LOO 3C-N 825
.012/.72 EC13 3300
.1/6 Lighting Panel 2P(N2T51 LOGIC Receptacle Panel FE-C3Rf 1100
.012/.72 2.'
"2T51 LOO 2A-N) 14 480 VAC 30. H2 Recombiner Power Supply FAL3L 1100
.012/.72 ED10 6600
.18/11 H2 Recombiner HTRS (Q2E17G001A-A)
FB-H6R 1100
.012/.72 EE10 9900
.18/11 H2 Recombiner HTRS (Q2E17G0018-B) i i
j Not required in modes 1-4 May be energized under administrative control when required for maintenance.
This portion of the table is not valid until after the second refueling outage except for the backup protection devices that have been installed prior to startup following the first refueling outage.
FARLEY - UNIT 2 3/4 8-28D


i l
l CONTAINMENT SYSTEMS CONTAINMENT VENTILATION SYSTEM LIMITING CONDITION FOR OPERATION 3.6.1.7 The 48-inch containment purge supply and exhaust isolation valves 6-inch containment I
l l
(CBV-HV-3198A, 31980, 3196, 3197) shall be closed.
CONTAINMENT SYSTEMS                                                                   l CONTAINMENT VENTILATION SYSTEM LIMITING CONDITION FOR OPERATION 3.6.1.7 The 48-inch containment purge supply and exhaust isolation valves (CBV-HV-3198A, 31980, 3196, 3197) shall be closed.           6-inch containment  I supply and exhaust isolation valves may be open. The)$
The)$
APPLICABILITY:   MODES 1, 2, 3, and 4.
supply and exhaust isolation valves may be open.
APPLICABILITY:
MODES 1, 2, 3, and 4.
ACTION:
ACTION:
With one 48-inch containment purge supply and/or one exhaust isolation valve open, close the open valve (s) within one hour or be in at least HOT STAND 8Y within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
With one 48-inch containment purge supply and/or one exhaust isolation valve open, close the open valve (s) within one hour or be in at least HOT STAND 8Y within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
SURVEILLANCE REQUIREMENTS 4.6.1.7.1 The 48-inch containment purge supply and exhaust isolation valves shall be determined closed at least once per 31 days.
SURVEILLANCE REQUIREMENTS 4.6.1.7.1 The 48-inch containment purge supply and exhaust isolation valves shall be determined closed at least once per 31 days.
R       WnD 4.6.1.7.2 The valve seals of the 48-inch and the J6-inch pwege supply and       k exhaust isolation valves shall be replaced at least once per 5 years.
R WnD 4.6.1.7.2 The valve seals of the 48-inch and the J6-inch pwege supply and k
h FARLEY-UNIT 2                         3/4 6-10 L
exhaust isolation valves shall be replaced at least once per 5 years.
h FARLEY-UNIT 2 3/4 6-10 L


1 i                                                                                             TABLE 3.7-4b SAFETY RELATED MECilAi4ICAL SNUBBERS
1 i
TABLE 3.7-4b SAFETY RELATED MECilAi4ICAL SNUBBERS
* l i
* l i
!                                                                                                                            HIGH RADIATION
HIGH RADIATION
'm             HANGER         NUMBER OF                   SYSTEM SNUBBER INSTALLED                     ACCESSIBLE OR                   ZONE             ESPECIALLY DIFFICULT
'm HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT
.E             NUMBER         SNUBBERS               ON, LOCATION AND ELEVATION                       INACCESSIBLE       DURING SHUTDOWN **                 TO REMOVE l{                                                                                                           (A or I)           (Yes or No)                   (Yes or No)
. E NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO REMOVE l{
(A or I)
(Yes or No)
(Yes or No)
}'
}'
; E AUX. STEAM
; E AUX. STEAM
,    -4
-4
)no       SS-13247                 2               Aux. Bl dg. El . 134' 1" and                                     A                   No                           No j                                                     135' 4 1/4", Room 2241                                                                                                     -
)no SS-13247 2
SS-13250               1               Aux. Bldg. El. 133' 2"                                           A                   No                           No
Aux. Bl dg. El. 134' 1" and A
]'                                                  Room 2241
No No j
'w         SS-13253               2               Aux. Bldg. Ei.133' 9" and                                       A                   No                           No ls                                             135' O 1/4", Room 2241 u
135' 4 1/4", Room 2241
L SS-13255               1               Aux. Bldg. El. 133' 3 1/2"                                       A                   No                           No Room 2241 SS-13721               2               Aux. Bldg. El. 101' 8 3/4"                                       A                   No                           No Room 2193 1
]'
SS-13250 1
Aux. Bldg. El. 133' 2" A
No No Room 2241
'w SS-13253 2
Aux. Bldg. Ei.133' 9" and A
No No ls 135' O 1/4", Room 2241 u
, L SS-13255 1
Aux. Bldg. El. 133' 3 1/2" A
No No Room 2241 SS-13721 2
Aux. Bldg. El. 101' 8 3/4" A
No No Room 2193 1
1 3
1 3
5             .
5
]
]
4 1
4 1
Line 334: Line 654:
4
4


                                                                          . . . - . . . - .        .-      -  .-.  . _- = , -        . --.        .-
. _ =, -
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* l HIGH RADIATION HANGER       NUMBER OF             SYSTEM SNUBBER INSTALLED                 ACCESSIBLE OR                 ZONE         ESPECIALLY DIFFICULT i j                   NUMBER       SNUBBERS             ON, LOCATION AND ELEVATION                 INACCESSIBLE     DURING SHUTDOWN **             TO REMOVE
* l HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i j NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
]g (A or I)             (Yes or No)           (Yes or No) je   CHEMICAL AND i
TO REMOVE
g VOLUME CONTROL
]g (A or I)
[     SS-11894                     1             CTMT Bldg. El. 118' 0"                               I                       Yes                   No NW Quadrant i
(Yes or No)
i       SS-11899                     2             CTMT Bldg. El. 117' 8"                               I                       Yes                   No l                                                     NW Quadrant j
(Yes or No) je CHEMICAL AND g VOLUME CONTROL i
'$y SS-11902                     2             CTMT Bldg. El. 113' 9" NW Quadrant I                       Yes                   No
[
.        SS-11974                     1             CTMT Bldg. El. 128' 10"                             I                       Yes                   No SW Quadrant SS-11991                     1             CTMT Bldg. El. 128' 8"                               I                       Yes                   No NE Quadrant SS-12002                     1             CTMT Bldg. El. 128' 4"                               I                       Yes                   No I
SS-11894 1
NW Quadrant j       SS-12003                     1             CTMT Bldg. El. 128' 10"                             I                       Yes                   No NW Quadrant
CTMT Bldg. El. 118' 0" I
)       SS-12010                     1             CTMT Bldg. El. 129' 2"                               I                       Yes                   No NE Quadrant
Yes No NW Quadrant i
i SS-11899 2
CTMT Bldg. El. 117' 8" I
Yes No l
NW Quadrant SS-11902 2
CTMT Bldg. El. 113' 9" I
Yes No j
NW Quadrant y
SS-11974 1
CTMT Bldg. El. 128' 10" I
Yes No SW Quadrant SS-11991 1
CTMT Bldg. El. 128' 8" I
Yes No NE Quadrant SS-12002 1
CTMT Bldg. El. 128' 4" I
Yes No I
NW Quadrant j
SS-12003 1
CTMT Bldg. El. 128' 10" I
Yes No NW Quadrant
)
SS-12010 1
CTMT Bldg. El. 129' 2" I
Yes No
]
]
SS-12011                     1             CTMT Bldg. El. 133' 0"                               I                       Yes                   No NE Quadrant l
NE Quadrant SS-12011 1
CTMT Bldg. El. 133' 0" I
Yes No NE Quadrant l
1
1


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* l i
* l i
j                                                                                                                                         HIGH RADIATION
j HIGH RADIATION s
;        s              HANGER         NUMBER OF                               SYSTEM SNUBBER INSTALLED ON, LOCATION AND ELEVATION ACCESSIBLE OR INACCESSIBLE ZONE DURING SHUTDOWN **
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT j
ESPECIALLY DIFFICULT TO REMOVE j         p2            NUMBER        SNUBBERS j        Q                                                                                                             (A or I)           (Yes or No)               (Yes or No) e I
p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
i         C i         5           SS-12013             2                         CTMT Bldg. El. 133' 0" and                           I                   Yes                         No
TO REMOVE j
          -d                                                          133' 9 5/8", NW Quadrant j
Q (A or I)
I m
(Yes or No)
SS-12114             1                         CTMT Bldg. El. 128' 10"                               I                   Yes                         No               ,
(Yes or No)
SW Quadrant SS-12146             1                         CTMT Bldg. El. 128' 10"                               I                   Yes                         No
I e
,        w                                                          SW Quadrant s
i C
i b          SS-12147             1                         CTMT Bldg. El. 128' 10"                               I                   Yes                         No l         E                                                           SW Quadrant l                     SS-12175             1                         CTMT Bldg. El. 125' 8 5/16"                           I                   Yes                         No SW Quadrant SS-12183             1                           CTMT Bldg. El. 128' 6"                               I                   Yes                         No SW Quadrant j                     SS-12184             1                         CTMT Bldg. El. 128' 6"                               I                   Yes                         No i                                                                     SW Quadrant SS-12185             1                           CTMT Bldg. El. 128' 6"                               I                   Yes                       No j                                                                     SW Quadrant
i 5
,                    SS-12213             1                           CTMT Bldg. El. 128' 8"                               I                     Yes                       No
SS-12013 2
  !                                                                    NE Quadrant SS-12231             1                         CTMT Bldg. El. 128' 5"                               I                   Yes         ,            No j                                                                     SE Quadrant l
CTMT Bldg. El. 133' 0" and I
Yes No j
133' 9 5/8", NW Quadrant
-d I
m SS-12114 1
CTMT Bldg. El. 128' 10" I
Yes No SW Quadrant SS-12146 1
CTMT Bldg. El. 128' 10" I
Yes No SW Quadrant w
s b
SS-12147 i
1 CTMT Bldg. El. 128' 10" I
Yes No l
E SW Quadrant l
SS-12175 1
CTMT Bldg. El. 125' 8 5/16" I
Yes No SW Quadrant SS-12183 1
CTMT Bldg. El. 128' 6" I
Yes No SW Quadrant j
SS-12184 1
CTMT Bldg. El. 128' 6" I
Yes No i
SW Quadrant SS-12185 1
CTMT Bldg. El. 128' 6" I
Yes No j
SW Quadrant SS-12213 1
CTMT Bldg. El. 128' 8" I
Yes No NE Quadrant SS-12231 1
CTMT Bldg. El. 128' 5" I
Yes No j
SE Quadrant l
1 1
1 1


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS *
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
^
^
HIGH RADIATION 5     HANGER       NUMBER OF             SYSTEM SNUBBER INSTALLED               ACCESSIBLE OR               ZONE         ESPECIALLY DIFFICULT P     NUMBER       SNUBBERS             ON, LOCATION AND ELEVATION             INACCESSIBLE     ~~
5 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT P
DURING SHUTDOWN **             TO REMOVE Q                                                                                   (A or I)             (Yes or No)               (Yes or No) i c:
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
SS-12237           1                 CTMT Bldg. El. 128' 5 7/8"                         I               Yes                         No
TO REMOVE Q
;                                          SE Quadrant SS-12242           1                 CTMT Bldg. El. 128' 9 1/2"                         I                 Yes                         No SE Quadrant SS-12269           1                 CTMT Bldg. El. 129' 8 3/4"                         I               Yes                         No NE Quadrant b S$-12274           1                 CTMT Bldg. El. 128' 2 3/4"                         I                 Yes                         No y                                       NW Quadrant i
(A or I)
j k   SS-12296           1                 CTMT Bldg. El. 115' 6"                             I               Yes                         No SE Quadrant SS-12346           1                 CTMT Bldg. El. 131' 6"                             I                 Yes                         No SE Quadrant
(Yes or No)
;      SS-12357           1                 CTMT Bldg. El. 124' 8 1/2"                         I               Yes                         No l                                           SE Quadrant SS-12368           1                 CTMT Bldg. El. 173' 1 5/16"                       I                 Yes                         No
(Yes or No)
;                                          NW Quadrant SS-12369           2                 CTMT Bldg. El. 169' 0 11/16"                       I               Yes                         No NW Quadrant SS-12370           2                 CTMT Bldg. El. 159' 9 3/16"                         I               Yes                         No NW Quadrant
~~
                                                ,                                          ..w.
i c:
SS-12237 1
CTMT Bldg. El. 128' 5 7/8" I
Yes No SE Quadrant SS-12242 1
CTMT Bldg. El. 128' 9 1/2" I
Yes No SE Quadrant SS-12269 1
CTMT Bldg. El. 129' 8 3/4" I
Yes No NE Quadrant b
S$-12274 1
CTMT Bldg. El. 128' 2 3/4" I
Yes No y
NW Quadrant j k SS-12296 i
1 CTMT Bldg. El. 115' 6" I
Yes No SE Quadrant SS-12346 1
CTMT Bldg. El. 131' 6" I
Yes No SE Quadrant SS-12357 1
CTMT Bldg. El. 124' 8 1/2" I
Yes No l
SE Quadrant SS-12368 1
CTMT Bldg. El. 173' 1 5/16" I
Yes No NW Quadrant SS-12369 2
CTMT Bldg. El. 169' 0 11/16" I
Yes No NW Quadrant SS-12370 2
CTMT Bldg. El. 159' 9 3/16" I
Yes No NW Quadrant
..w.


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION
,i   HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR         ZONE     ESPECIALLY DIFFICULT 35   NUMBER SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE DURING SHUTDOWN **     TO REMOVE
,i HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
}e (A or I)       (Yes or No)       (Yes or No)
TO REMOVE
E SS-12372     1     CTMT Bldg. El. 138' 11 5/16"           I               Yes               No Q                     NW Quadrant m
}
SS-12456     1     CTMT Bldg. El. 115' 10 1/4"           I               Yes               No SW Quadrant SS-12459     1     CTMT Bldg. El. 114' 10 5/8"           I               Yes               No 3g                     SW Quadrant u
(A or I)
-a SS-12473     2     CTMT Bldg. El. 120' 6 1/2"             I               Yes               No h                     SW Quadrant a.
(Yes or No)
SS-12474     1     CTMT Bldg. El.120' 0"                 I               Yes               No SW Quadrant SS-12476     1     CTMT Bldg. El. 120' 0"                 I               Yes               No SW Quadrant SS-12477     1     CTMT Bldg. El. 120' 0"                 I               Yes               No SW Quadrant SS-12482     1     ClMT Bldg. El. 125' 0"                 I               Yes               No SW Quadrant SS-12483     1     CTMT Bldg. El. 125' 0"                 I               Yes               No SW Quadrant SS-12484     2     CTMT Bldg. El. 125' 0"                 I               Yes               No NW Quadrant
(Yes or No) e E SS-12372 1
CTMT Bldg. El. 138' 11 5/16" I
Yes No Q
NW Quadrant m
SS-12456 1
CTMT Bldg. El. 115' 10 1/4" I
Yes No SW Quadrant SS-12459 1
CTMT Bldg. El. 114' 10 5/8" I
Yes No 3g SW Quadrant u
-a SS-12473 2
CTMT Bldg. El. 120' 6 1/2" I
Yes No h
SW Quadrant a.
SS-12474 1
CTMT Bldg. El.120' 0" I
Yes No SW Quadrant SS-12476 1
CTMT Bldg. El. 120' 0" I
Yes No SW Quadrant SS-12477 1
CTMT Bldg. El. 120' 0" I
Yes No SW Quadrant SS-12482 1
ClMT Bldg. El. 125' 0" I
Yes No SW Quadrant SS-12483 1
CTMT Bldg. El. 125' 0" I
Yes No SW Quadrant SS-12484 2
CTMT Bldg. El. 125' 0" I
Yes No NW Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER-INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 N'JMB ER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
  ,    HANGER     NUMBER OF                 SYSTEM SNUBBER-INSTALLED     ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT 35     N'JMB ER   SNUBBERS                 ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE
TO REMOVE
}e (A or I)       (Yes or No)       (Yes or No)
}
E    SS-12526         2                     CTMT Bldg. El.109' 7"                 I               Yes               No El                                         112' 0", SE Quadrant to SS-12527         2                     CTMT Bldg. El. 111' 4 1/2"             I               Yes               No 112' 0", SE Quadrant SS-12528         1                     CTMT Bldg. El. 112' 0"                 I               Yes               No ya                                         SE Quadrant a
(A or I)
w   SS-12373         1                     CTMT Bldg. El. 138' 11 5/16"           I               Yes               No j;                                         NW Quadrant a
(Yes or No)
Ss-12543         1                     CTMT Bldg. El.108' 6"                 I               Yes               No NE Quadrant 55-12545         1                     CTMT Bldg. El. 108' 6"                 I               Yes               No NE Quadrant SS-12547         1                     CTMT Bldg. El. 110' 0"                 I               Yes               No NE Quadrant SS-12634         1                     CTMT Bldg. El. 122' 10 1/2"           I               Yes               No SE Quadrant SS-12639         1                     CTMT Bldg. El.123' 0"                 I               Yes               No SE Quadrant SS-12648         1                     CTMT Bldg. El. 128' 6"                 I               Yes               No SE Quadrant
(Yes or No) e E
SS-12526 2
CTMT Bldg. El.109' 7" I
Yes No El 112' 0", SE Quadrant to SS-12527 2
CTMT Bldg. El. 111' 4 1/2" I
Yes No 112' 0", SE Quadrant SS-12528 1
CTMT Bldg. El. 112' 0" I
Yes No ya SE Quadrant a
w SS-12373 1
CTMT Bldg. El. 138' 11 5/16" I
Yes No j;
NW Quadrant a
Ss-12543 1
CTMT Bldg. El.108' 6" I
Yes No NE Quadrant 55-12545 1
CTMT Bldg. El. 108' 6" I
Yes No NE Quadrant SS-12547 1
CTMT Bldg. El. 110' 0" I
Yes No NE Quadrant SS-12634 1
CTMT Bldg. El. 122' 10 1/2" I
Yes No SE Quadrant SS-12639 1
CTMT Bldg. El.123' 0" I
Yes No SE Quadrant SS-12648 1
CTMT Bldg. El. 128' 6" I
Yes No SE Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION l ,,    HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT i
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT l
3;   NUMBER SNUBBERS   ON, LOCATION AND ELEVATION   INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE
3; NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
{I (A or I)       (Yes or No)       (Yes or No)
TO REMOVE i {
Ei SS-12677     1     CTMT Bldg. El. 125' 2 1/2"           I               Yes               No q                     SE Quadrant n
(A or I)
SS-12684     1     CTMT Bldg. El. 129' 2"               I               Yes               No NE Quadrant SS-12685     1     CTMT Bldg. El. 132' 8 3/4"           I               Yes               No w                      NE Quadrant 2
(Yes or No)
SS-12686     1     CTMT Bldg. El. 129' 9 1/2"           I               Yes               No g                     NE Quadrant SS-12687   'l     CTMT Bldg. El. 132' 7"               I               Yes               No NE Quadrant SS-12700     1     CTMT Bldg. El. 122' 10 5/8"           I               Yes               No SW Quadrant SS-12701     1     CTMT Bldg. El.122' 10 5/8''           I               Yes               No SW Quadrant SS-12703     1     CTMT Bldg. El. 122' 3"               I               Yes               No SW Quadrant SS-12705     1     CTMT Bldg. El. 122' 3"               I               Yes               No SW Quadrant SS-12713     1     CTMT Bldg. El. 124' O 15/16"         I               Yes               No NW Quadrant
(Yes or No)
I Ei SS-12677 1
CTMT Bldg. El. 125' 2 1/2" I
Yes No q
SE Quadrant n
SS-12684 1
CTMT Bldg. El. 129' 2" I
Yes No NE Quadrant SS-12685 1
CTMT Bldg. El. 132' 8 3/4" I
Yes No NE Quadrant w2 SS-12686 1
CTMT Bldg. El. 129' 9 1/2" I
Yes No y
g NE Quadrant SS-12687
'l CTMT Bldg. El. 132' 7" I
Yes No NE Quadrant SS-12700 1
CTMT Bldg. El. 122' 10 5/8" I
Yes No SW Quadrant SS-12701 1
CTMT Bldg. El.122' 10 5/8''
I Yes No SW Quadrant SS-12703 1
CTMT Bldg. El. 122' 3" I
Yes No SW Quadrant SS-12705 1
CTMT Bldg. El. 122' 3" I
Yes No SW Quadrant SS-12713 1
CTMT Bldg. El. 124' O 15/16" I
Yes No NW Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION y     HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT p2   NUMBER SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **       TO REMOVE Q                                                         (A or I)       (Yes or No)         (Yes or No)
* HIGH RADIATION y
-4 SS-12714     1     CTMT Bldg. El.124' O 15/16"           I               Yes                 No NW Quadrant ro SS-127I6     1     CTMT Bldg. El. 124' O 15/16"           I               Yes                 No NW Quadrant SS-12717     1     CTMT Bldg. El. 124' 0 15/16"           I               Yes                 No w                      NW Quadrant 2
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
SS-12720     1     CTMT Bldg. El. 122' 6"                 I               Yes                 No g                     NW Quadrant c
TO REMOVE Q
SS-12721     1     CTMT Bldg. El.123' 3"                 I               Yes                 No NW Quadrant SS-12/22     1     CTMT Bldg. El. 123' 3"                 I               Yes                 No NW Quadrant SS-12723     1     CTMT Bldg. El .123' 3"                 I               Yes                 No NW Quadrant SS-12762     2     CTMT Bldg. El. 107' 11 7/8"           I               Yes                 No and 108' O 1/8", SE Quadrant SS-12763     2     CTMT Bldg. El. 108' 0"                 I               Yes                 No SE Quadrant SS-12766     1     CTMT Bldg. El. 121' 7"                 I               Yes                 No SE Quadrant
(A or I)
(Yes or No)
(Yes or No)
SS-12714 1
CTMT Bldg. El.124' O 15/16" I
Yes No
-4 NW Quadrant ro SS-127I6 1
CTMT Bldg. El. 124' O 15/16" I
Yes No NW Quadrant SS-12717 1
CTMT Bldg. El. 124' 0 15/16" I
Yes No NW Quadrant w2 SS-12720 1
CTMT Bldg. El. 122' 6"
I Yes No y
g NW Quadrant c
SS-12721 1
CTMT Bldg. El.123' 3" I
Yes No NW Quadrant SS-12/22 1
CTMT Bldg. El. 123' 3" I
Yes No NW Quadrant SS-12723 1
CTMT Bldg. El.123' 3" I
Yes No NW Quadrant SS-12762 2
CTMT Bldg. El. 107' 11 7/8" I
Yes No and 108' O 1/8", SE Quadrant SS-12763 2
CTMT Bldg. El. 108' 0" I
Yes No SE Quadrant SS-12766 1
CTMT Bldg. El. 121' 7" I
Yes No SE Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION 32     HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT p2     NUMBER SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE Q                                                           (A or I)       (Yes or No)       (Yes or No) i SS-12478     1     CfMT Bldg. El. 120' 0"                 I               Yes               No SW Quadrant ro SS-12718     1     CTMT Bldg. El. 122' 6"                 I               Yes               No NW Quadrant SS-12350     1     CTMT Bldg. El. 132' 3 5/8"             I               Yes               No w                      SE Quadrant 5
* HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
SS-12344     1     CTMT Bldg. El. 129' 6"                 I               Yes               No g                       SE Quadrant r
TO REMOVE Q
SS-13704     1     Aux. Bldg. El . 136' 3 1/2"           A                 Yes               No Room 2206
(A or I)
(Yes or No)
(Yes or No) i SS-12478 1
CfMT Bldg. El. 120' 0" I
Yes No SW Quadrant ro SS-12718 1
CTMT Bldg. El. 122' 6"
I Yes No NW Quadrant SS-12350 1
CTMT Bldg. El. 132' 3 5/8" I
Yes No SE Quadrant w5 SS-12344 1
CTMT Bldg. El. 129' 6" I
Yes No y
g SE Quadrant r
SS-13704 1
Aux. Bldg. El. 136' 3 1/2" A
Yes No Room 2206


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION g       HANGER     NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT p       NUMBER   SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE g                                                               (A or I)         (Yes or No)       (Yes or No) 1 E COMPONENT COOLING WATER N   SS-12129         1     CTMT Bldg. El. 133' 5 3/4"           I                 Yes               No SW Quadrant SS-12131           1     CTMT Bldg. El. 133' 5 3/4"             I               Yes               No SW Quadrant
* HIGH RADIATION g
$$  SS-12135         1     CTMT Bldg. El. 132' 8 3/4"           I                 Yes               No SW Quadrant
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p
SS-12152         1     CTMT Bldg. El. 133' 0"               I                 Yes               No SW Quadrant SS-12154         1     CTMT Bldg. El. 126' 2 5/16"           I                 Yes               No SW Quadrant SS-12155         1     CTMT Bldg. El. 133' 0"               I                 Yes               No SW Quadrant SS-12249         1     CTMT Bldg. El. 133' 8 3/4"           I                 Yes               No NW Quadrant SS-12254         1     CTMT Bldg. El. 126' 2 5/16"           I                 Yes               No SE Quadrant SS-12516         1       CTMT Bldg. El. 132' 3"               I                 Yes               No NW Quadrant
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO REMOVE g
(A or I)
(Yes or No)
(Yes or No) 1 E COMPONENT COOLING WATER N
SS-12129 1
CTMT Bldg. El. 133' 5 3/4" I
Yes No SW Quadrant SS-12131 1
CTMT Bldg. El. 133' 5 3/4" I
Yes No SW Quadrant SS-12135 1
CTMT Bldg. El. 132' 8 3/4" I
Yes No SW Quadrant SS-12152 1
CTMT Bldg. El. 133' 0" I
Yes No SW Quadrant SS-12154 1
CTMT Bldg. El. 126' 2 5/16" I
Yes No SW Quadrant SS-12155 1
CTMT Bldg. El. 133' 0" I
Yes No SW Quadrant SS-12249 1
CTMT Bldg. El. 133' 8 3/4" I
Yes No NW Quadrant SS-12254 1
CTMT Bldg. El. 126' 2 5/16" I
Yes No SE Quadrant SS-12516 1
CTMT Bldg. El. 132' 3" I
Yes No NW Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* i
* i HIGH RADIATION
;                                                                                                  HIGH RADIATION
: 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i E2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
: 32         HANGER       NUMBER OF     SYSTEM SNUBBER INSTALLED             ACCESSIBLE OR                     ZONE ESPECIALLY DIFFICULT i E2         NUMBER       SNUBBERS     ON, LOCATION AND ELEVATION             INACCESSIBLE     DURING SHUTDOWN **       TO REMOVE C2                                                                               (A or I)     (Yes or No)           (Yes or No) i C
TO REMOVE C2 (A or I)
~5     SS-12517               1     CTMT 81dg. El. 132' 1"                             I                       Yes           No
(Yes or No)
  ' -d i                                     NW Quadrant N
(Yes or No) i C
l eem i
~ 5 SS-12517 1
CTMT 81dg. El. 132' 1" I
Yes No
' -d i
NW Quadrant N
l e
em i
8 m.
8 m.
4 1
4 1
Line 431: Line 973:


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION HANGER     NUMBER OF                                         SYSTEM SNUBBER INSTALLED         ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
  $      NUMBER     SNUBBERS                               ON, LOCATION AND ELEVATION                 INACCESSIBLE DURING SHUTDOWN **       TO REMOVE
TO REMOVE
  -}                                                                                                         (A or I)     (Yes or No)         (Yes or No)
-}
CONTAINMENT SPRAY Z   2CS-R198               2                     CTMT Bldg. E1. 273' 0"                                   I             No                   Yes m                                                   SW Quadrant 2CS-R199               2                       CTMT Bldg. E1. 273' 0"                                   I             No                   Yes SW Quadrant w   2CS-R202               2                       CTMT Bldg. El. 255' 0"                                   I             No                   Yes 3s                                                   SE Qt'adrant u
(A or I)
E   2CS-R203             2                       CTMT Bldg. E1. 255' 0"                                   I             No                   Yes
(Yes or No)
  #                                                  NE Quadrar.t 2CS-R254               2                       CTMT Bldg. El. 268' 0"                                   I             No                   Yes SE Quadrant 2CS-R266             2                       CTMT Bldg. El. 266' 7"                                   I             No                   Yes SW Quadrant i
(Yes or No)
CONTAINMENT SPRAY Z
2CS-R198 2
CTMT Bldg. E1. 273' 0" I
No Yes m
SW Quadrant 2CS-R199 2
CTMT Bldg. E1. 273' 0" I
No Yes SW Quadrant w
2CS-R202 2
CTMT Bldg. El. 255' 0" I
No Yes 3s SE Qt'adrant u
E 2CS-R203 2
CTMT Bldg. E1. 255' 0" I
No Yes NE Quadrar.t 2CS-R254 2
CTMT Bldg. El. 268' 0" I
No Yes SE Quadrant 2CS-R266 2
CTMT Bldg. El. 266' 7" I
No Yes SW Quadrant i
4
4
_ _ _ _ _ _ . _ _ _ _ . _m._. __________ __ _              --_.---_._a_
: m..
--.---. a


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION 32               HANGER                     NUMBER OF   SYSTEM SNUBBER INSTALLED           ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT P!               NUMBER                     SNUBBERS   ON, LOCATION AND ELEVATION       -
* HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT P!
INACCESSIBLE   DURING SHUTDOWN **       TO REMOVE C2                                                                                             (A or I)       (Yes or No)       (Yes.or No)
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO REMOVE C2 (A or I)
(Yes or No)
(Yes.or No)
't C
't C
* LIQUID WASTE DISPOSAL SS-12494                         1     CTMT Bldg. El.108' 6"                       I               Yes                   No SW Quadrant SS-12496                         1     CTNT Bldg. El. 108' 1"                       I               Yes                   No SW Quadrant b           SS-12521                         1     CTMT Bldg. El. 107' 9 7/8"                   I               Yes                   No y                                                     NW Quadrant b           SS-12523                         2     CTMT Bldg. El. 107' 1"                       I               Yes                   No NW Quadrant SS-12533                         1     CTMT Bldg. El. 107' 8 3/4"                   I               Yes                   No NW Quadrant SS-12534                         1     CTMT Bldg. El. 107' 8 3/4"                   I               Yes                   No NW Quadrant SS-12659                         1     CTMT Bldg. El. 108' 6"                       I               Yes                   No SE Quadrant SS-12660                         1     CTMT Bldg. El. 107' 6 1/2"                   I               Yes-                 No SE Quadrant SS-12662                         1     CTMT Bldg. El. 107' 5 1/8"                   I               Yes                   No SE Quadrant
* LIQUID WASTE DISPOSAL SS-12494 1
CTMT Bldg. El.108' 6" I
Yes No SW Quadrant SS-12496 1
CTNT Bldg. El. 108' 1" I
Yes No SW Quadrant b
SS-12521 1
CTMT Bldg. El. 107' 9 7/8" I
Yes No y
NW Quadrant b
SS-12523 2
CTMT Bldg. El. 107' 1" I
Yes No NW Quadrant SS-12533 1
CTMT Bldg. El. 107' 8 3/4" I
Yes No NW Quadrant SS-12534 1
CTMT Bldg. El. 107' 8 3/4" I
Yes No NW Quadrant SS-12659 1
CTMT Bldg. El. 108' 6" I
Yes No SE Quadrant SS-12660 1
CTMT Bldg. El. 107' 6 1/2" I
Yes-No SE Quadrant SS-12662 1
CTMT Bldg. El. 107' 5 1/8" I
Yes No SE Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* 31 ??
* 31
C!
??
HIGH RADIATION
i C!
    $    HANGER.         NUMBER OF           SYSTEM SNUBBER INSTALLED                   ACCESSIBLE OR               ZONE     ESPECIALLY DIFFICULT
HIGH RADIATION HANGER.
    -4   NUMBER         SNUBBERS           ON, LOCATION AND ELEVATION                 INACCESSIBLE       DURING SHUTDOWN **           TO REMOVE N                                                                                        (A or I)         (Yes or No)             (Yes or No) i SS-12522               1             CTMT Bldg. El. 107' 9 3/4"                         I                   Yes                     No NW Quadrant 2
NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT
SS-13660               1             Aux. Bldg. El. 103' 10"                             A                   No                       No j                                           Room 2184 2WP-BR70               1             ClMT Bldg. El. 106' 11 1/4"                         I                   Yes                     No Se                                       SW Quadrant N
-4 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO REMOVE (A or I)
(Yes or No)
(Yes or No)
N i
SS-12522 1
CTMT Bldg. El. 107' 9 3/4" I
Yes No NW Quadrant 2
SS-13660 1
Aux. Bldg. El. 103' 10" A
No No j
Room 2184 2WP-BR70 1
ClMT Bldg. El. 106' 11 1/4" I
Yes No Se SW Quadrant N
a i
a i
l l
l l
Line 462: Line 1,059:
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* i i
* i i
HIGH RADIATION
HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT B
  ,                HANGER         NUMBER OF             SYSTEM SNUBBER INSTALLED                                     ACCESSIBLE OR               ZONE                           ESPECIALLY DIFFICULT B               NUMBER         SNUBBERS             ON, LOCATION AND ELEVATION                                   INACCESSIBLE       DURING SHUTDOWN **                             TO REMOVE ip                                                                                                                      (A or I)           (Yes or No)                             (Yes or No) j -c
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO REMOVE i p (A or I)
(Yes or No)
(Yes or No)
-c j
!Ej MAIN STEAM Q
!Ej MAIN STEAM Q
j no       SS-13177                           1       Aux. Bldg. El. 128' 3 1/4"                                           A                     No                                         No Room 2241
j no SS-13177 1
* l          SS-13179                           2       Aux. Bldg. El. 127' 9"                                               A                     No                                         No Room 2241
Aux. Bldg. El. 128' 3 1/4" A
  $$      SS-13213                           1       Au x. Bld g. El . 128' 8"                                           A                     No                                         No
No No Room 2241 l
.y                                                   Room 2241 l L.
SS-13179 2
,y         SS-13217                           1       Aux. Bldg. El. 128' 8"                                               A                     No                                         No i                                                     Room 2241 SS-13242                           2       Aux. Bldg. El. 127' 7"                                               A                     No                                         No 1                                                      dnd 127' 3 3/4", Room 2241 SS-13367                           1       Aux. Bldg. El. 127' 3 3/4"                                           A                     No                                         No 3
Aux. Bldg. El. 127' 9"
Room 2241
A No No Room 2241 SS-13213 1
,          SS-13725                           1       Au x. Bldg. El .12 /' 8 3/8"                                         A                     No                                         No Room 2241 J
Au x. Bld g. El. 128' 8" A
SS-14790                         1       Aux. Bldg. El. 127' 3 3/4"                                           A                     No                                         No Rcom 2241 l                                                                                                         ,
No No Room 2241
.y l L.
,y SS-13217 1
Aux. Bldg. El. 128' 8" A
No No i
Room 2241 SS-13242 2
Aux. Bldg. El. 127' 7" A
No No dnd 127' 3 3/4", Room 2241 1
SS-13367 1
Aux. Bldg. El. 127' 3 3/4" A
No No Room 2241 3
SS-13725 1
Au x. Bldg. El.12 /' 8 3/8" A
No No Room 2241 J
SS-14790 1
Aux. Bldg. El. 127' 3 3/4" A
No No Rcom 2241 l
i t
i t
1
1


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION s     HANGER NUMBER OF   SYSTEM SNUBBER INSTALI.E3     ACCESSIBLE OR         ZONE     ESPECIALLY DIFFICULT
* HIGH RADIATION s
#    NUMBER SNUBBERS   ON, LOCATION AND ELEVATION   RACCESSIBLE   DURING SHUTDOWN **     TO REMOVE Q                                                         (A or I)       (Yes or No)       (Yes or No) i b
HANGER NUMBER OF SYSTEM SNUBBER INSTALI.E3 ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT NUMBER SNUBBERS ON, LOCATION AND ELEVATION RACCESSIBLE DURING SHUTDOWN **
SS-15757     1     Aux. Bldg. El. 127' 3 3/4"           A               No                 No Room 2241 m
TO REMOVE Q
SS-15772     1     Aux. Bldg. El. 129' 3"               A               No                 No Roo:a 2241 w
(A or I)
(Yes or No)
(Yes or No) i b
SS-15757 1
Aux. Bldg. El. 127' 3 3/4" A
No No Room 2241 m
SS-15772 1
Aux. Bldg. El. 129' 3" A
No No Roo:a 2241 w
b N
b N
8'
8'
Line 486: Line 1,111:
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* 4 l
* 4 l
HIGH RADIATION
HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i E NUMBER SNUBBERS ON, LCCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
      ,            HANGER   NUMBER OF           SYSTEM SNUBBER INSTALLED               ACCESSIBLE OR                       ZONE         ESPECIALLY DIFFICULT iE                NUMBER   SNUBBERS           ON, LCCATION AND ELEVATION               INACCESSIBLE         DURING SHUTDOWN **               TO REMOVE (A or I)
TO REMOVE (A or I)
      @                                                                                                          (Yes or No)                 (Yes or No)
(Yes or No)
]'     2 REACTOR COOLANT
(Yes or No)
,      Z   2RC-BR1             1             CTMT Bldg. El. 172' 1"                             I                         Yes                     No m                                      NW Quadrant i
]'
!          2RC-R116             2             CTMT Bldg. El. 168' 5"                             I                         Yes                       No j
REACTOR COOLANT 2
NW Quadrant 2
Z 2RC-BR1 1
2RC-R6               1             CTMT Bldg. El. 174' 1 5/16"                       I                         Yes                     No c3                                           NW Quadrant
CTMT Bldg. El. 172' 1"
  ,u
I Yes No NW Quadrant m
! I.       2RC-R7               2             CTMT Bldg. El.175' 2"                             I                         Yes                       No
i 2RC-R116 2
CTMT Bldg. El. 168' 5" I
Yes No j
NW Quadrant w
2RC-R6 1
CTMT Bldg. El. 174' 1 5/16" I
Yes No 2
c3 NW Quadrant
,u
! I.
2RC-R7 2
CTMT Bldg. El.175' 2" I
Yes No
! if NW Quadrant l
! if NW Quadrant l
i         2RC-R8               2             CTMT Bldg. El. 161' 1"                             I                         Yes                     No NW Quadrant 2RC-R9               1             CTMT Bldg. El. 174' 4 1/8"                         I                         Yes                       No NW Quadrant 2RC-R11             2             CTMT Bldg. E1         171' 1"                     I                         Yes                     No NW Quadrant 2RC-R18             2             CTMT Bldg. El. 163' 0"                             I                         Yes                       No NW Quadrant 2RC-R94             1             CTMT Bldg. El. 171' 4 1/8"                         I                         Yes                     No i
i 2RC-R8 2
j NW Quadrant i
CTMT Bldg. El. 161' 1" I
Yes No NW Quadrant 2RC-R9 1
CTMT Bldg. El. 174' 4 1/8" I
Yes No NW Quadrant 2RC-R11 2
CTMT Bldg. E1 171' 1" I
Yes No NW Quadrant 2RC-R18 2
CTMT Bldg. El. 163' 0" I
Yes No NW Quadrant 2RC-R94 1
CTMT Bldg. El. 171' 4 1/8" I
Yes No NW Quadrant i
j i


J                                                                           TABLE 3.7-4b i
J TABLE 3.7-4b i
SAFETY RELATED MECHANICAL SNUBBERS
SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION HANGER         NUMBER OF     SYSTEM SNUBBER INSTALLED       ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT 5       NUMBER         SNUBBERS     ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE f                                                                         (A or I)       (Yes or No)       (Yes or No)
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 5
              -e
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
2RC-R95                 1       CTMT Bldg. El. 171' 4 1/8"               I               Yes               No g;                                 NW Quadrant
TO REMOVE f
              "  2RC-R98                 2       CTMT Bldg. E l .160' 5"                 I               Yes               No NW Quadrant 2RC-R117               1       CTMT Bldg. El. 169' 10"                 I               Yes               No NW Quadrant f( 2RC-R123X               1       CTMT Bldg. El. 169' 10"                 I               Yes               No NW Quadrant jf2RC-R133X                 1       CTMT Bldg. Ei. 169' 10"                 I               Yes               No j                                                 NW Quadrant 2RC-R139               2       CTMT Bldg. 21. 167' 10 1/2"             I               Yes               No NW Quadrant                                                                             ,
(A or I)
2RC-R129X               2       CTMT Bldg. El. 159' 5"                   I               Yes               No NW Quadrant 2RC-R128X             2       CTMT Bldg. El. 151' 9 1/2"               I               Yes               No NW Quadrant l                 2RC-R127X               2       CTMT Bldg. El. 146' 0"                   I               Yes               No
(Yes or No)
.                                                NW Quadrant 2RC-R10               2       CTMT Bldg. El. 173' 9"                   I               Yes               No NW Quadrant d
(Yes or No)
-e 2RC-R95 1
CTMT Bldg. El. 171' 4 1/8" I
Yes No g;
NW Quadrant 2RC-R98 2
CTMT Bldg. E l.160' 5" I
Yes No NW Quadrant 2RC-R117 1
CTMT Bldg. El. 169' 10" I
Yes No NW Quadrant f( 2RC-R123X 1
CTMT Bldg. El. 169' 10" I
Yes No NW Quadrant jf2RC-R133X 1
CTMT Bldg. Ei. 169' 10" I
Yes No j
NW Quadrant 2RC-R139 2
CTMT Bldg. 21. 167' 10 1/2" I
Yes No NW Quadrant 2RC-R129X 2
CTMT Bldg. El. 159' 5" I
Yes No NW Quadrant 2RC-R128X 2
CTMT Bldg. El. 151' 9 1/2" I
Yes No NW Quadrant l
2RC-R127X 2
CTMT Bldg. El. 146' 0" I
Yes No NW Quadrant 2RC-R10 2
CTMT Bldg. El. 173' 9" I
Yes No NW Quadrant d
v
v


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
,      HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED         ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT 35     NUMBER SNUBBERS   ON, LOCATION AND ELEVATION       INACCESSIBLE DURING SHUTDOWN **     TO REMOVE h                                                             (A or I)     (Yes or No)         (Yes or No) 2RC-R141     1     CTMT Bldg. El. 172' 6 5/8"                 I             Yes                 No
TO REMOVE h
!!                      NW Quadrant a
(A or I)
m 2RC-R144       1     CTMT Bldg. El. 172' 4 1/8"                 I             Yes                 No NW Quadrant 2RC-R12     1     CTMT Bldg. El. 171' 4"                     I             Yes                 No NW Quadrant 2RC-R113     2     CTMT Bldg. El. 159' 4"                   I             Yes                 No y                       NW Quadrant
(Yes or No)
(Yes or No) 2RC-R141 1
CTMT Bldg. El. 172' 6 5/8" I
Yes No NW Quadrant a
m 2RC-R144 1
CTMT Bldg. El. 172' 4 1/8" I
Yes No NW Quadrant 2RC-R12 1
CTMT Bldg. El. 171' 4" I
Yes No NW Quadrant 2RC-R113 2
CTMT Bldg. El. 159' 4" I
Yes No y
NW Quadrant
.o.
.o.
T 2RC-R147       2     CTMT Bldg. El. 167' 10 1/2"               I             Yes                 No NW Quadrant 2RC-R136     2     CTMT Bldg. El. 167' 10 1/2"               I             Yes                 No NW Quadrant 2RC-R142     1     CTMT Bldg. El. 172' 11 1/2"               I             Yes                 No NW Quadrant 2RC-R132X   2     CTMT Bldg. El. 169' 10"                   I             Yes                 No NW Quadrant 2RC-R124X   2     CTMT Bldg. El. 169' 10"                   I             Yes               No NW Quadrant 2RTD-R191   1     CTMT Bldg. El. 127' 1"                   I             Yes               No NE Quadrant
T 2RC-R147 2
CTMT Bldg. El. 167' 10 1/2" I
Yes No NW Quadrant 2RC-R136 2
CTMT Bldg. El. 167' 10 1/2" I
Yes No NW Quadrant 2RC-R142 1
CTMT Bldg. El. 172' 11 1/2" I
Yes No NW Quadrant 2RC-R132X 2
CTMT Bldg. El. 169' 10" I
Yes No NW Quadrant 2RC-R124X 2
CTMT Bldg. El. 169' 10" I
Yes No NW Quadrant 2RTD-R191 1
CTMT Bldg. El. 127' 1"
I Yes No NE Quadrant


                                                              -,as.
-,as.
TABLE 3.7-4b                                     -
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION                   "' ?'
"' ?'
  ,      HANGER     NUMBER OF   SYSTEM SNUBBER INSTALLED         ACCESSIBLE OR           ZONE       ESPECIALLY DIFFICULT E         NUMBER     SNUBBERS   ON, LOCATION AND ELEVATION       INACCESSIBLE   DURING SHUTDOWN **       TO REMOVE
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E
@                                                                      (A or I)       (Yes or No)         (Yes or No) 2RTD-R190         1     CTMT Bldg. El. 125' 6"                   I                 Yes                 No E                     .        NE Quadrant "1
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
    '2kTD-R173                 CTMT Bldg. El. 123' 10"                 I                 Yes                 No             'N
TO REMOVE (A or I)
_                SW Quadrant                                                                               ,
(Yes or No)
T      2RTD-R175 .s .
(Yes or No) 2RTD-R190 1
1    CTMT Bldg. El. 123' 10"u                 I       ~         Yes                 No SW Quadrant                                   _
CTMT Bldg. El. 125' 6" I
2RTD-R172         1     CTMT Bldg. El. 123' 10"                 I                 Yes                 No y                               SW Quadrant
Yes No E
NE Quadrant
'2kTD-R173 "1
CTMT Bldg. El. 123' 10" I
Yes No
'N SW Quadrant
.s 1
CTMT Bldg. El. 123' 10"u I
~
Yes No T
2RTD-R175 SW Quadrant 2RTD-R172 1
CTMT Bldg. El. 123' 10" I
Yes No y
SW Quadrant
.c.
.c.
E 2RTD-R157               1     CTMT Bldg. El. 126' 6"                   I                 Yes                 Yes             ..
E 2RTD-R157 1
NW Quadrant 2RTD-R183         1     CTMT Bldg. El. 124' 3"                   I                 Yes                 No SE Quadrant 2RTD-R182         1     CTMT Bldg. El. 124' 3"                   I                 Yes                 No SE Quadrant 2RTD-R187         1     CTMT Bldg. El. 124' 10"                 I                 Yes                 No NE Quadrant 2RTD-R192         1     CTMT Bldg. El. 126' 8"                   I                 Yes                 No NE Quadrant 2RTD-R177         1     CTMT Bldg. El. 126' 6"                   I                 Yes                 No SE Quadrant
CTMT Bldg. El. 126' 6" I
Yes Yes NW Quadrant 2RTD-R183 1
CTMT Bldg. El. 124' 3" I
Yes No SE Quadrant 2RTD-R182 1
CTMT Bldg. El. 124' 3"
I Yes No SE Quadrant 2RTD-R187 1
CTMT Bldg. El. 124' 10" I
Yes No NE Quadrant 2RTD-R192 1
CTMT Bldg. El. 126' 8" I
Yes No NE Quadrant 2RTD-R177 1
CTMT Bldg. El. 126' 6" I
Yes No SE Quadrant


            .-                                -        _                            . _ .                            .= .
.=
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION m      HANGER     NUMBER OF   SYSTEM SNUBBER INSTALLED                 ACCESSIBLE OR                         ZONE             ESPECIALLY DIFFICULT L"     NUMBER     SNUBBERS   ON, LOCATION AND ELEVATION               INACCESSIBLE                 DURING SHUTDOWN **                 TO REMOVE
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT m
    }'
L" NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
(A or I)                       (Yes or No)               (Yes or No)
TO REMOVE
,      2RTD-R180       1     CTMT Bldg. El. 126' 6"                             I                             Yes                           No E                           SE Quadrant
}
  .w N 2RTD-R185       1     CTMT Bldg. El.124' 3"                             I                             Yes                           No                           .
(A or I)
SE Quadrant                                                                                                                           -
(Yes or No)
                                                                                                                                                                            ~
(Yes or No) 2RTD-R180 1
2RTD-BR9                                                                   I CTMT. Bldg. El. 126' 6" s    1                                                                    -
CTMT Bldg. El. 126' 6" I
Yes                           No           .
Yes No E
SE Quadrant
.w N
2RTD-R185 1
CTMT Bldg. El.124' 3" I
Yes No SE Quadrant
~
2RTD-BR9 1
CTMT. Bldg. El. 126' 6" I
Yes No s
SE Quadrant
SE Quadrant
                                                                                                            /
/
ea                                                                                                                                 .
ea
    'a 2RTD-BR10       1 CTMT Bldg._El. 124' 3"                             I                             Yes                           No       -
'a 2RTD-BR10 1
y                          SE Quadrant a
CTMT Bldg._El. 124' 3" I
    #  2RTD-BR2         1     CTMT Bldg. El. 124' 2"                             I                             Yss           -
Yes No y
No                 ,
SE Quadrant a#
NE Quadrant                             ,
2RTD-BR2 1
7
CTMT Bldg. El. 124' 2" I
                                                                              ~                                                      '
Yss No NE Quadrant 7
2RTD-BR4'       1     CTMT Bldg. El. 123' 10"                           I                             Yes                           N o '-
2RTD-BR4' 1
SW Quadrant                                                                                           ~
CTMT Bldg. El. 123' 10"
2RTD-BR6         1     CTMT Bldg. El. 124' 10"                           I                             Yes                           No                           '
~
                  -            NE Quadrant 2RTD-BR11       1     CTMT Bldg. El. 126' 6"                             I                             Yes                           Yes NW Quadrant                                                                                               .
I Yes N o '-
s
SW Quadrant
                                                                                                                                                                  .e.
~
l                 4 A,                ,
2RTD-BR6 1
                                            ,                      ;~                         _
CTMT Bldg. El. 124' 10" I
              .&                                      .4                                             -                                                                    4
Yes No NE Quadrant 2RTD-BR11 1
CTMT Bldg. El. 126' 6" I
Yes Yes NW Quadrant s
.e.
l 4
A,
;~
.4 4


                                                  ?
a.
a.
TABLE 3.7-4b       _:
?
                                          ' SAFETY RELATED MECHANICAL SNUBBERS *
TABLE 3.7-4b
* HIGH RADIATION m   HANGER     NUMBER OF     SYSTEM SNUBBER INSTALLED         ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT E   NUMBER     SNUBBERS     ON, LOCATION AND ELEVATION         INACCESSIBLE   DURING SHUTDOWN **     TO-REMOVE h                                                                     (A or I)       (Yes or No)       (Yes or No)
' SAFETY RELATED MECHANICAL SNUBBERS
[ SS-11924         2       CTMT Bldg. El. 128' 6 3/16" and             I               Yes               No z                            129' 2 11/16", SW Quadrant H
* HIGH RADIATION m
N SS-11933         2       CTMT Bldg. El. 128' 7" and                 I               Yes               No 129' 3 1/2", NW Quadrant SS-11945         2       CTMT Bldg. El. 128' 7 7/8"                 I               Yes               No and 129' 4 3/8", SE Quadrant SS-12536         1       CTMT Bldg. El. 140' 5"                       I               Yes               No y                           NW Quadrant a
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E
E SS-12553         1       CTMT Bldg. El. 154' 1 5/8"                 I               Yes               No NW Quadrant SS-12559         1       CTMT Bldg. El. 162' 1 1/16"                 I               Yes               Yes NW Quadrant SS-12754         1       CTMT Bldg. El. 119' 3"                     I               Yes               No SW Quadrant SS-12316         1       CTMT Bldg. El.111' 3"                       I               Yes               No NE Quadrant SS-12324         1       CTMT Bldg. El. 109' 1"                     I               Yes               No SE Quadrant
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
TO-REMOVE h
(A or I)
(Yes or No)
(Yes or No)
[
SS-11924 2
CTMT Bldg. El. 128' 6 3/16" and I
Yes No 129' 2 11/16", SW Quadrant z
H N
SS-11933 2
CTMT Bldg. El. 128' 7" and I
Yes No 129' 3 1/2", NW Quadrant SS-11945 2
CTMT Bldg. El. 128' 7 7/8" I
Yes No and 129' 4 3/8", SE Quadrant SS-12536 1
CTMT Bldg. El. 140' 5" I
Yes No y
NW Quadrant a
E SS-12553 1
CTMT Bldg. El. 154' 1 5/8" I
Yes No NW Quadrant SS-12559 1
CTMT Bldg. El. 162' 1 1/16" I
Yes Yes NW Quadrant SS-12754 1
CTMT Bldg. El. 119' 3" I
Yes No SW Quadrant SS-12316 1
CTMT Bldg. El.111' 3" I
Yes No NE Quadrant SS-12324 1
CTMT Bldg. El. 109' 1" I
Yes No SE Quadrant


TABLE 3.7-4b-SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b-SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION g       HANGER   NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT p2     NUMBER   SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE DURING SHUTDOWN **     TO REMOVE Q                                                             (A or I)       (Yes or No)       (Yes or No) h SAFETY INJECTION 5
* HIGH RADIATION g
-4   2SI-BR7         1     CTMT Bldg. E1. 114' 9"                 I             Yes                 No N
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
SW Quadrant 2SI-BR9         1     CTMT Bldg. El.113' 10"                 I             Yes                 No SW Quadrant M.
TO REMOVE Q
(A or I)
(Yes or No)
(Yes or No) h SAFETY INJECTION 5
-4 2SI-BR7 1
CTMT Bldg. E1. 114' 9" I
Yes No N
SW Quadrant 2SI-BR9 1
CTMT Bldg. El.113' 10" I
Yes No SW Quadrant M.
.a Y
.a Y
hRESIDUALHEATREMOVAL SS-10319       1     Aux. Bldg. El. 103' 6"                 A             No                 -No Room 2184
hRESIDUALHEATREMOVAL SS-10319 1
Aux. Bldg. El. 103' 6" A
No
-No Room 2184


i TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS *
i TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
  ,                                                                                              HIGH RADIATION im           HANGER     NUMBER OF               SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR           ZONE       ESPECIALLY DIFFICULT
* HIGH RADIATION im HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT
( h!       NUMBER     SNUBBERS               ON, LOCATION AND ELEVATION   INACCESSIBLE     DURING SHUTDOWN **     TO REMOVE lq                                                                               (A or I)       (Yes or No)         (Yes or No) l E STEAM GENERATOR BLOWDOWN N     SS-12793         1                   CTMT Bldg. El. 123' 6"                     I           Yes-               No SE Quadrant SS-12794         1                   CTMT Bldg. El. 122' 6"                     I           Yes                 No
( h!
;                                              SE Quadrant
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
}$$     SS-12797         1                   CTMT Bldg. El. 123' 6"                     I           Yes                 No y                                          SE Quadrant SS-12798         1                   CTMT Bldg. El. 123' 6"                     I           Yes                 No SE Quadrant SS-12799         1                   CTMT Bldg. El.128' 1"                       I           Yes                 No SE Quadrant i'        SS-12802         1                   CTMT Bldg. El. 138' 2 1/4"                 I           Yes                 No SE Quadrant j         SS-12806         2                   CTMT Bldg. El. 151' 0"                     I           Yes                 No SE Quadrant S5-12827         2                   CTMT Bldg. El. 151' 0"                     I           Yes                 No SW Quadrant SS-12830         1                   CTMT Bldg. El. 139' 0 1/2"                 I           Yes                 No SW Quadrant
TO REMOVE lq (A or I)
(Yes or No)
(Yes or No) l E STEAM GENERATOR BLOWDOWN N
SS-12793 1
CTMT Bldg. El. 123' 6" I
Yes-No SE Quadrant SS-12794 1
CTMT Bldg. El. 122' 6" I
Yes No SE Quadrant
}$$
SS-12797 1
CTMT Bldg. El. 123' 6" I
Yes No SE Quadrant
< y SS-12798 1
CTMT Bldg. El. 123' 6" I
Yes No SE Quadrant SS-12799 1
CTMT Bldg. El.128' 1" I
Yes No SE Quadrant i
SS-12802 1
CTMT Bldg. El. 138' 2 1/4" I
Yes No SE Quadrant j
SS-12806 2
CTMT Bldg. El. 151' 0" I
Yes No SE Quadrant S5-12827 2
CTMT Bldg. El. 151' 0" I
Yes No SW Quadrant SS-12830 1
CTMT Bldg. El. 139' 0 1/2" I
Yes No SW Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 3;
  ,,    HANGER       NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR             ZONE       ESPECIALLY DIFFICULT 3;   NUMBER       SNUBBERS   ON, LOCATION AND ELEVATION     INACCESSIBLE   DURING SHUTDOWN **           TO REMOVE (A or I)         (Yes or No)         (Yes or No)
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
I E SS-12833           1     CTMT Bldg. El. 125' 3"                 I                 Yes                   Yes Z                             SW Quadrant i m SS-12834           1     CTMT Bldg. El. 125' 4 1/4"             I                 Yes                   Yes l                               SW Quadrant SS-12835           1     CTMT Bldg. El.128' 6"                 I                 Yes                   Yes
TO REMOVE (A or I)
,3                               SW Quadrant y  SS-12848           10     CTMT Bldg. El. 134' 1 5/16"           I                 Yes                   No g                             SE Quadrant
(Yes or No)
,x SS-12862           1     CTMT Bldg. El.123' 4"                 I                 Yes                   No SW Quadrant SS-12863           1     CTMT Bldg. El. 126' 3"                 I                 Yes                   No SW Quadrant SS-12866           1     CTMT Bldg. El. 122' 6"                 I                 Yes                   Yes SW Quadrant SS-12867           2     CTMT Bldg. El. 131' 8"                 I                 Yes                 No SE Quadrant SS-12871           1     CTMT Bldg. El. 124' 9"                 I                   Yes                 No NE Quadrant SS-12872             1     CTMT Bldg. El. 121' 7"                 I                 Yes                 No NE Quadrant
(Yes or No)
I E
SS-12833 1
CTMT Bldg. El. 125' 3" I
Yes Yes Z
SW Quadrant i m SS-12834 1
CTMT Bldg. El. 125' 4 1/4" I
Yes Yes l
SW Quadrant SS-12835 1
CTMT Bldg. El.128' 6" I
Yes Yes SW Quadrant
,3 SS-12848 10 CTMT Bldg. El. 134' 1 5/16" I
Yes No y
g SE Quadrant
,x SS-12862 1
CTMT Bldg. El.123' 4" I
Yes No SW Quadrant SS-12863 1
CTMT Bldg. El. 126' 3" I
Yes No SW Quadrant SS-12866 1
CTMT Bldg. El. 122' 6" I
Yes Yes SW Quadrant SS-12867 2
CTMT Bldg. El. 131' 8" I
Yes No SE Quadrant SS-12871 1
CTMT Bldg. El. 124' 9" I
Yes No NE Quadrant SS-12872 1
CTMT Bldg. El. 121' 7"
I Yes No NE Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 3;
  ,,    HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR         ZONE     ESPECIALLY DIFFICULT 3;     NUMBER SNUBBERS   ON, LOCATION AND ELEVATION     JNACCESSIBLE DURING SHUTDOWN **     TO REMOVE
NUMBER SNUBBERS ON, LOCATION AND ELEVATION JNACCESSIBLE DURING SHUTDOWN **
{1 (A or I)       (Yes or No)       (Yes or No)
TO REMOVE
Ei SS-12877     1     CTMT Bldg. El. 121' 7"                 I               Yes               No Z                       NW Quadrant N
{
SS-12878     1     CTMT Bldg. El. 121' 1"                 I               Yes               No NW Quadrant SS-12882     2     CTMT Bldg. El. 134' 0 9/16"           I               Yes               No 3a                     NE Quadrant
(A or I)
  =
(Yes or No)
SS-12883     2     CTMT Bldg. El. 134' 4 1/16"           I               Yes               No g                       NE Quadrant w
(Yes or No) 1 Ei SS-12877 1
SS-12886     1     CTMT Bldg. El. 151' 0"                 I               Yes               No NE Quadrant SS-12887     1     CTMT Bldg. El. 151' 0"               I               Yes               No NE Quadrant SS-12888     2     CTMT Bldg. El. 151' 0"                 I               Yes               Yes NE Quadrant SS-12889     1     CTMT Bldg. El. 151' 0"                 I               Yes               Yes NE Quadrant SS-12891     1     CTMT Bldg. El. 150' 0"                 I               Yes               Yes l                         NE Quadrant SS-12896     1     CTMT Bldg. El. 128' 4"                 I               Yes               No NE Quadrant
CTMT Bldg. El. 121' 7" I
Yes No Z
NW Quadrant N
SS-12878 1
CTMT Bldg. El. 121' 1" I
Yes No NW Quadrant SS-12882 2
CTMT Bldg. El. 134' 0 9/16" I
Yes No 3a NE Quadrant
=
SS-12883 2
CTMT Bldg. El. 134' 4 1/16" I
Yes No y
g NE Quadrant w
SS-12886 1
CTMT Bldg. El. 151' 0" I
Yes No NE Quadrant SS-12887 1
CTMT Bldg. El. 151' 0"
I Yes No NE Quadrant SS-12888 2
CTMT Bldg. El. 151' 0" I
Yes Yes NE Quadrant SS-12889 1
CTMT Bldg. El. 151' 0" I
Yes Yes NE Quadrant SS-12891 1
CTMT Bldg. El. 150' 0" I
Yes Yes l
NE Quadrant SS-12896 1
CTMT Bldg. El. 128' 4" I
Yes No NE Quadrant


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E
  ,,    HANGER NUMBER OF   SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR           ZONE     ESPECIALLY DIFFICULT E     NUMBER SNUBBERS   ON, LOCATION AND ELEVATION   INACCESSIBLE   DURING SHUTDOWN **     TO REMOVE
NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
  }.
TO REMOVE
(A or I)       (Yes or No)       (Yes or No)
}
Ei SS-12897     1     CTMT Bldg. El. 128' 4"               I               Yes               No y                       NE Quadrant ro SS-12899     1     CTMT Bldg. El. 131' 7 1/16"           I               Yes               No NE Quadrant SS-12900     2     CTMT Bldg. El. 144' 0"               I               Yes               Yes NE Quadrant a
(A or I)
SS-12906     1     CTMT Bldg. El. 106' O 1/4"           I               Yes               No g                       SW Quadrant N
(Yes or No)
SS-12940     1     CTMT Bldg. El. 127' 4"               I               Yes               No SW Quadrant SS-12942     2     CTMT Bldg. El. 127' 4"               I               Yes               Yes SW Quadrant SS-12944     3     CTMT Bldg. El.127' 4"                 I               Yes               Yes SW Quadrant SS-12946     1     CTMT Bldg. El. 127' 4"               I               Yes               No SW Quadrant SS-12951     3     CTMT Bldg. El. 128' 4 1/2"           I               Yes               Yes SW Quadrant SS-13536     3     Aux. Bldg. El. 134' 9 1/4"           A               No                 No 135' 0", Raom 2237
(Yes or No)
Ei SS-12897 1
CTMT Bldg. El. 128' 4" I
Yes No y
NE Quadrant ro SS-12899 1
CTMT Bldg. El. 131' 7 1/16" I
Yes No NE Quadrant SS-12900 2
CTMT Bldg. El. 144' 0" I
Yes Yes NE Quadrant a
SS-12906 1
CTMT Bldg. El. 106' O 1/4" I
Yes No y
g SW Quadrant N
SS-12940 1
CTMT Bldg. El. 127' 4" I
Yes No SW Quadrant SS-12942 2
CTMT Bldg. El. 127' 4" I
Yes Yes SW Quadrant SS-12944 3
CTMT Bldg. El.127' 4" I
Yes Yes SW Quadrant SS-12946 1
CTMT Bldg. El. 127' 4" I
Yes No SW Quadrant SS-12951 3
CTMT Bldg. El. 128' 4 1/2" I
Yes Yes SW Quadrant SS-13536 3
Aux. Bldg. El. 134' 9 1/4" A
No No 135' 0", Raom 2237


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION 32       HANGER NUMBER OF       SYSTEM SNUBBER INSTALLED     ACCESSIBLE OR         ZONE     ESPECIALLY DIFFICULT p2       NUMBER SNUBBERS       ON, LOCATION AND ELEVATION     INACCESSIBLE DURING SHUTDOWN **     TO REMOVE Q                                                               (A or I)       (Yes or No)       (Yes or No)
* HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
I
TO REMOVE Q
!!    SS-13538     3         Aux. Bldg. El. 130' 9"               A               No                 No
(A or I)
-i                           Room 2237 m
(Yes or No)
SS-13546     3         Aux. Bldg. El. 134' 6"               A               No                 No Room 2188 SS-13810     1         Aux. Bldg. El. 136' 3"               A               No                 No u,                           Room 2608
(Yes or No)
-1
I SS-13538 3
.y    SS-13812     1         Aux. Bldg. El. 130' 9 1/2"           A               No                 No 1,                           Room 2608 8
Aux. Bldg. El. 130' 9"
* SS-13819     1         Aux. Bldg. El. 135' 2 1/4"           A               Yes               No Room 2223 SS-13826     3         Aux. Bldg. El. 133' 0"               A               Yes               No Room 2223 SS-15064     1         Aux. Bldg. El. 132' 10 5/8"           A               No                 No Room 2609 SS-15065     1         Aux. Bldg. El. 132' 10 5/8"           A               No                 No Room 2609 SS-15066     1         Aux. Bldg. El. 132' 10 5/8"           A               No                 No Room 2609 SS-15067     1         Aux. Bldg. El. 132' 5 3/8"           A               No                 No Room 2609
A No No
-i Room 2237 m
SS-13546 3
Aux. Bldg. El. 134' 6" A
No No Room 2188 SS-13810 1
Aux. Bldg. El. 136' 3" A
No No Room 2608 u,
-1 SS-13812 1
Aux. Bldg. El. 130' 9 1/2" A
No No
.y 1,
Room 2608 8
SS-13819 1
Aux. Bldg. El. 135' 2 1/4" A
Yes No Room 2223 SS-13826 3
Aux. Bldg. El. 133' 0" A
Yes No Room 2223 SS-15064 1
Aux. Bldg. El. 132' 10 5/8" A
No No Room 2609 SS-15065 1
Aux. Bldg. El. 132' 10 5/8" A
No No Room 2609 SS-15066 1
Aux. Bldg. El. 132' 10 5/8" A
No No Room 2609 SS-15067 1
Aux. Bldg. El. 132' 5 3/8" A
No No Room 2609


TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS
* HIGH RADIATION
* HIGH RADIATION s
,  s            HANGER       NUMBER OF       SYSTEM SNUBBER INSTALLED           ACCESSIBLE OR         ZONE       ESPECIALLY DIFFICULT F2           NUMBER       SNUBBERS     ON, LOCATION AND ELEVATION             INACCESSIBLE DURING SHUTDOWN **     TO REMOVE
HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT F2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **
[]                                                                               (A or I)     (Yes or No)         (Yes or No) i b
TO REMOVE
SS-15068             1       Aux. Bldg. El. 132' 5 3/8"                   A               No                 No   '  -
[]
Room 2609 ro SS-15069             1       Aux. Bldg. El. 132' 5 3/8"                   A               No                 No         --
(A or I)
Room 2609 i
(Yes or No)
kt a
(Yes or No) i b
u i
SS-15068 1
Aux. Bldg. El. 132' 5 3/8" A
No No Room 2609 ro SS-15069 1
Aux. Bldg. El. 132' 5 3/8" A
No No Room 2609 kt i
a u
b i
b i
l
i l
* Snubbers may be added to safety related systems without prior License Amendment to Table 3.7-4b provided that a revision to Table 3.7-4b is included with the next License Amendment request.
Snubbers may be added to safety related systems without prior License Amendment to Table 3.7-4b provided that a revision to Table 3.7-4b is included with the next License Amendment request.
!        **    Modifications to this column due to changes in high radiation areas may be made without prior License Amendment provided that a revision to Table 3.7-4b is included with the next License Amendment request.
Modifications to this column due to changes in high radiation areas may be made without prior License Amendment provided that a revision to Table 3.7-4b is included with the next License Amendment request.
t i
t i
_ . -}}
_. -}}

Latest revision as of 11:45, 16 December 2024

Proposed Tech Spec Changes Re Containment Penetration Overcurrent Protection,Containment Vent Valves & safety- Related Mechanical Snubbers
ML20066K830
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 11/24/1982
From:
ALABAMA POWER CO.
To:
Shared Package
ML20066K814 List:
References
NUDOCS 8211290663
Download: ML20066K830 (43)


Text

ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES FNP-2 1.

Table 3.8-1, pg. 3/4 8-20 through 3/4 8-28D 2.

Section 3/4.6.1.7, pg. 3/4 6 -10 3.

Table 3.7-4b, pg 3/4 7-49 through 3/4 7-49bb e

l 8211290663 821124 PDR ADOCK 05000364 PDR

TABLC 3.8-1 CONTAIN;;ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Davice Number Setpoint Time Device Number Point Time System i

and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered 4

1.

4160VAC Switchgears (NOTE: Response includes relay initiation time & breaker clearing time.)

DA04 10560

.09/5.4 DA01 18480

.39/9.2 Reactor Coolant Pump 2A D803 10560

.09/5.4 0B01 16500 39/9.2 Reactor Coolant Pump 2B DC03 10560

.09/5.4 DC04 15310

.39/9.2 Reactor Coolant Pump 2C 2.

600VAC Load Centers i

EA04 2750

.18/11 EPPC-2A CP-1 MSCP Type X N/A Reactor Polar Crane i

EA10 1980

.10/6 EPPC-2A CP-2 MSCP Type X N/A Containment Cooler 2A (Normal)

E805 1980

.10/6 EPPC-2A CP-6 MSCP Type X N/A Containment Cooler 28 (Normal)

EB06 1980

.10/6 EPPC-2E CP-2 MSCP Type X N/A Containment Cooler 2C (Normal)

EC12 1980

.10/6 EPPC-2D CP-1 MSCP Type X N/A Containment Cooler 2D (Normal)

ED11 1320

.10/6 EPPC-2A CP-3 MSCP Type X N/A CRDM Cooler Fan 2A ED15 1650

.10/6 EPPC-2A CP-4 MSCP Type X N/A Containment Cooler 2A (Emergency)

ED16 1650

.10/6 EPPC-2A CP-5 MSCP Type X N/A Containment Cooler 2B (Emergency)

EE08 1650

.10/6 EPPC-2D CP-2 MSCP Type X N/A Containment Cooler 2C (Emergency)

EE13 1320

.10/6 EPPC-2D CP-3 MSCP Type X N/A CRDM Cooler Fan 28 l

EE16 1650

.10/6 EPPC-2D CP-4 MSCP Type X N/A Containment Cooler 2D (Emergency) 3.

600VAC Motor Control Centers FA-F7 231

.012/.72 EPPC-28 CP-1 MSCP Type S N/A Reactor Cavity C1g Fan Mtr.

FA-16 11 012/.72 EPPC-2B CP-2 MSCP Type S N/A Reactor Cavity Cool Fan Mov FA-15 116

.012/.72 EPPC-2B CP-3 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2D FA-J5 116

.012/.72 EPPC-2B CP-4 MSCP Type S N/A CTMT Post LOCA Air Mixing fan 2C FARLEY - UNIT 2 3/4 8-20 i

TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location.

(Ampere)

(Sec/ Cycles)

Powered FB-13 116 012/ 72 EPPC-2F CP-1 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2B FB-!4 116

.012/.72 EPPC-2F CP-2 MSCP Type S N/A CTMT Post LOCA Air Mixing Fan 2A FD-H7R 770 012/.72 EPPC-2G CP-1 MSCP Type S N/A CTMT G1B Crane (N2T31K005-N)

FB-J7 231 012/.72 EPPC-2F CP-3 MSCP Type S N/A Reactor Cavity Cig Fan Mtr.

FB-A4R 770

.012/.72 EPPC-2F CP-4 MSCP Type S N/A CTMT Elevator No. 3 Control FC-P3 116 012/.72 EPPC-2C CP-1/2 MSCP Type S N/A CTMT Dome Recire. Fan 2A FC-P4 116 012/.72 EPPC-2C CP-3/4 MSCP Type S N/A CTMT Dome Recirc. Fan 2B RCP Motor Space Heaters FC-!2*

770

.012/.72 FC-14 138

.012/.72 EPPC-2C CP-5 MSCP Type S N/A RCP BRG Oil Lif t Pump FC-N3 138 012/.72 EPPC-2C CP-6 MSCP Type S N/A RCP BRG 011 Lift Pump Refueling Wtr Surf ace Supply FC-J3*

232 012/.72 Refueling Wtr Surface Exhaust FC-M5*

693 012/.72 FC-J5 363 012/.72 EPPC-2C CP-7 MSCP Type S N/A CTMT Pre-Access Fan Motors RCP Mtr Space Heaters 2C FC-N4*

770 012/.72 Receptacles Term. Box 2A FC-J6Li 1100 012/.72 Reactor Cavity Filter Pmp FC-J6R*

770

.012/.72 Recep.

Up Ending Frame Winch str FC-S3L*

770

.012/.72 FC-M4L 770 012/.72 EPPC-2C CP-8 MSCP Type S N/A CTMT GIB Crane (N2T31K004-N)

Reactor Cavity Manipulator FC-N2L*

770

.012/.72 Crane FC-53R 770 012/.72 EPPC-2C CP-9 MSCP Type $

N/A CTMT GIB Crane (N2T31K006-N)

SW Port Drain Pump Recept.

FC-C5R*

770

.012/.72 FD-D6 138

.012/.72 EPPC-2G CP-2 MSCP Type S N/A RCP BRG 011 Lift Pump FD-E3 116

.012/ 72 EPPC-2G CP-3/4 MSCP Type S N/A CTMT Dome Recirculation Fan 2D FD-84 363

.012/.72 EPPC-2G CP-5 MSCP Type S N/A Reactor Cool Drain Tank Pump 2B FD-C2 138

.012/.72 EPPC-2G CP-6 MSCP Type S N/A CTMT Sump Pump Mtr 2A FD-D2 138 012/.72 EPPC-2G CP-7 MSCP Type S N/A CTMT Sump Pump Mtr 28 FD-C4 363

.012/.72 EPPC-2G CP-8 MSCP Type S N/A CTMT Pre-Access Fan Mtrs RCP Mtr Space Heaters 2B FO-G3*

770 012/.72 Receptacles Term Box 2C FD-A3Li 1100

.012/.72 3/4 8-21 FARLEY - UNIT 2

TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMAkV PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Davice Number Setpoint Time Device Number Point Time System and Location (Amperel (Sec/ Cycles) and Location (Ampere)

(Sec / Cycl es.).

Powered FE-A6 363

.012/.72 EPPC-2G CP-9 MSCP Type 5 M/A Reactor Cool Drain Tank Pump 2A Receptacles Term Box 2B FE-A4Lt 1100

.012/.72 FE-C3L 1100

.012/.72 EPPC-2G CP-10 MSCP Type S N/A Incore Det. Drive & Cont. Pni.

FE-HS 116

.012/.72 EPPC-2G CP-11/12 MSCP Type S N/A CTMT Dome Recirc. Fan 2C FU-G2 32 012/.72 EPPC-28 CP-5 MSCP Type $

N/A RHR Pumps Inlet Mov FU-H2 13 012/.72 EPPC-28 CP-6 MSCP Type S N/A CTMT Air Cooling Fan Mov FU-H3 13

.012/.72 EPPC-2B CP-7 MSCP Type S N/A CTMT Air Cooling Fan Mov FU-H4 11 012/.72 EPPC-2B CP-8 MSCP Type S N/A RCP Motor Cooler Disch Mov FU-J4 11 012/.72 EPPC-2B CP-9 MSCP Type S N/A CTMT To Atmos Diff Press Mov FU-K4 25

.012/.72 EPPC-2B CP-10 MSCP Type S N/A Pressurizer to Relief Tank MOV FU-K6 11

.012/.72 EPPC-2B CP-11 MSCP Type S N/A CTMT Cooler Disch MOV FU-L4 13

.012/.72 EPPC-2B CP-12 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FU-L5 13

.012/.72 EPPC-2B CP-13 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FU-T4 25

.012/.72 EPPC-2B CP-14 MSCP Type S N/A RCP Seal Water Return Isol.

FU-M4 13

.012/.72 EPPC-28 CP-15 MSCP Type S N/A Post ACDT Air Sampler Return Mov FU-RS 18

.012/.72 EPPC-2B CP-16 MSCP Type S N/A CTMT Air Sampler Mov.

FU-V4 13

.012/.72 EPPC-2B CP-17 MSCP Type S N/A CRDM Cool Fan Damprs Mov.

FU-W2 18

.012/.72 EPPC-28 CP-18 MSCP Type S N/A CTMT Air Cooler Disch Mov.

FU-W4 32

.012/.72 EPPC-2B CP-19 MSCP Type S N/A Reactor Cavity H2 Dilution Fan VLV 2A FU-T5 50

.012/.72 EPPC-2B CP-20 MSCP Type S N/A RHR System Inlet Isoi. V1v.

FU-Z2 523 012/.72 Q2R188032-A 1100 012/.72 Accumulator 2A Disch. Viv.

FU-23 523

.012/.72 Q2R18B031-A 1100

.012/.72 Accumulator 2C Disch. V1v.

FV-M3 13 012/.72 EPPC-2F CP-5 MSCP Type S N/A Post ACDT Air Sampler Return Mov.

FV-H4 13

.012/.72 EPPC-2F CP-6 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FV-HS 13

.012/.72 EPPC-2F CP-7 MSCP Type S N/A Post ACDT Air Sampler From CTMT Mov FARLEY - UNIT 2 3/4 8-22

TABLE 3.8-1 CONTAIN TENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

W Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location

{ Ampere)

(Sec/ Cycles)

Powered FV-Y4 13 012/.72 EPPC-2F CP-8 MSCP Type S N/A Post LOCA CTMT Vent Mov FV-YS 32

.012/.72 EPPC-2F CP-9 MSCP Type S N/A Instr. Air Line Disch. Mov.

FV-12 13

.012/.72 EPPC-2F CP-10 MSCP Type S N/A CRDM Cool Fan Damper FV-J4 18

.012/.72 EPPC-2F CP-11 MSCP Type S N/A CTMT Air Cooler Disch. Mov.

FV-J5 18

.012/.72 EPPC-2F CP-12 MSCP Type S N/A CTMT Air Cooler Disch. Mov.

FV-N2 32 012/.72 EPPC-2F CP-13 MSCP Type S N/A Reac. Cavity H2 Dilution Fan Viv. 2B FV-52 523

.012/.72 Q2R188035-B 1100

.012/.72 Accumulator 18 Disch. Viv.

FV-V3 50

.012/.72 EPPC-2F CP-14 MSCP Type S N/A RHR System Inlet 1s01. V1v.

FV-W4 25 012/.72 EPPC-2F CP-15 MSCP Type S N/A Pressurizer to Relief Isol.

Mov.

FV-V2 50

.012/.72 EPPC-2F CP-16 MSCP Type S N/A RHR System Outlet Isol. Viv.

FV-C3 25

.012/.72 EPPC-2F CP-17 MSCP Type S N/A RCP CCW Return from 011 Clr FV-F2 13

.012/.72 EPPC-2F CP-IP MSCP Type S N/A CTMT Air Cooling Fan Mov.

FV-F3 13

.012/.72 EPPC-2F CP-19 MSCP Type S N/A CTMT Air Coo 11ag Fan MOV.

FB-02 50

.012/.72 EPPC-2F CP-21 MSCP Type S N/A Reactor Cav Cooling Fan MOV.

4 208 VAC Motor Control Centers HA-03 116 012/.72 EPPC-2B CP-23 MSCP Type N N/A Reac. Cavity H2 Dilution Fan 2A HB-N7 116 012/.72 EPPC-2F CP-23 MSCP Type N N/A Reac. Cavity H2 Dilution Fan 2B HB-L7R/HD-N6L 1100 012/.72 Rod Pos. Ind 2000

.015/ 9 Digital Rod Position Control (40ABKR) Distr.

and Indication Pnl.

5.

600VAC Pressurizer Distr. Pn1 2A Circuit Bkrs.

BKR #1 1760

.316/1' BKR #2 1750 016/1 BKR #3 1760

.016/1 EA-11 3300

.18/11 Pressurizer Htr Group 2A Terminal Box N2TB010 BKR #4 1760

.016/1 t

.016/1]

BKR #5 1760

\\

i g

5 3/4 8-23 FARLEY - UNIT 2 J

..\\

. ~..

(

c t

\\,,

[.Y, j

N}-

'3

}*

1 T_ABLE 3.8 1 1

\\

I e

t.

's

\\

f' i

' gNTAtleMENT PENETRATION CONDUCTC,R

~

'N { -,f {

't A

s uvERCURRENT PROTECTIVE DEVICLS U

\\

BT,CKUP PROTECTION **

P21 MARY P40 TECTI'N _(y x' Response Trip set

Response

O

. _N_

.N Trip

' Device Number Setpoint_ i

.i {ime Device Number Point Time 9gg System Qmpere)

(Sec/ Cycles)s K

) Poweref s

a_nd Location (Ampere) ylde/ Cycles),

's and Location _

t.

N, m' s

1

')

N--

1. g - g t.

d ' 6.

600VAC Pressurizer N

cx 3 ;

N N

~"

's N'f,istr. Pn1 2B

~

, J-g(

's M

N - '!Cftcuit Bkrs.' %

(

,3

- s

.s N ',

- )

s

-.)

r

x EKR #1
  • \\

1/60 016/1 s

D CO - -,

010/1

'N s 'N i N

Pressbjzer Htr Croup b-s BKR #3

' N.174"

.G~df i

' EC-11

\\1 i300 K

.18/11 7-BKR #2 Terminar eox N2TB011

~\\

J 7$,

016/1

,4),

~

g BKR #4

\\ t760

.016/1

-4, q

SKR #5 s

7.

600VAC Pressurizer

.\\

,\\

. 'i.(

H L'r. D t s t r '. Pn l 2C T

g Circut; Bkrs.

.' s.'

,, k 3

.s

\\,'

3 s

PER #1 1540

.018/1.1 \\

I 4

BKR #2 1540 018/1.1 4

1 x

s BKR #3 1940

.018/1.1

(

.1 BKR #4 1540 018/1.1 EF-04 5

4400

.18/11 Pressurizer Htr Group 2C -

Terminal Box N2TB008 BKR #4 1540

.018/1.1 j

BKR #5 1540

(.018/1.1 BKR #6 1540 018/1.1

)I BXR #7 1540

.018/1.1 8.

600VAC Pressurizer Htr. Distr. Pn1 2D Circuit Bkrs.

BKR #1 1540

.018/1.1 BKR #2 1540

.018/1.1 EM-05 3300

.18/11 Pressurizer Htr Group 2D Terminal Box N2TB007 BKR #3 1540 018/1.1

(

BKR #4 1540

.108/1.1 j

s i

FARLEY - UNIT 2 3/4 8-24 i

i

TABLE 3.8-1 CONTAIN ENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered 9.

600VAC Pressurizer l

HTR. Distr. Pn1 2E Circuit Bkrs.

BKR #1 1540

.018/1.1 BKR #2 1540 018/1.1 4

i BKR #3 1540 018/1.1 EN-07 (Unit 1) 3300

.18/11 Pressurizer Htr Group 2E BKR #4 1540 018/1.1 Terminal Box N2TB009 l

BKR #5 1540

.018/1.1 1

1 10.

125VDC Sol. Vivs.

j Power Fuses,

o FBI (TC-OSA) 3 N/A DC Dist Pn1 2A CKT fil 770 012/.72 PRZR PWR Relief VLV (4454) 2A j

FBI (TC-254) 3 N/A at Dist Pn1 2D CKT #7 770

.012/.72 PRZR PWR Relief VLV (444B) 28 FB5 (TC-06A) 3 N/A OC Dist.Pn1 2A CKT #17 770

.012/.72 Letdown Line Isol. Viv. (459)

FB5 (TC-06A) 3 N/A DC.Ditt Pn1 2A CKT #17 770 012/.72-

' Letdown Line Isol. Viv. (460)

FB5 (TC-05A) 3 N/A DC Dist Pnl 2A CKT #11 770

.C12/.72-Reac. Cool Drn Tank Pump )

Disch. Viv (100)

FB6 (TC-05A) 3 N/A DC Dist Pn1 2A CKT #11 770

.012/.72-Reac. Cool Drn. Tank Venc Isol. Viv. (712)

FB3 (TC-06A) 3 N/A DC Dist Pnl 2A CKT #17 770

.012/.72 RMW to RCP Standpipe Fili (8168C)

FB4 (TC-258) 3 N/A DC Dist Pn1 2D CKT #7 770 012/.72 PRZR Rel. Tnk to RMW 1s01.

~,

l Viv. (8030)

FB5 (TC 258) 3 N/A DC _Dist Pnt 2D CKT #7 770

.012/.72 PRZR Rel. Tnk Drn to WPS Drn.

Tek (8030)

FB6 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770

.012/.72 Excess Letdown Isol. Viv.

~

(8153)

FB5 (TC-278) 3 N/A DC Dist Pn1 20 CKT #18 770 012/.72 RCS PRZR Aux. Spray V1v.

(8145) fB7 (TC-278) 3 N/A DC Dist Pnl 2D CKT #15 770

.012/.72

" Excess Letdown Isol. Viv.

(8154) 4 e

!~

/

0

.w

/

f' p.

FARLEY - UNIT'2 -

3/4 8-25

~

~

^

9

' eme(

nh, Y

m 4

TABLE 3.8-1 I

/

CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECT!vE DEVICES BACKUP PROTECTIGu **

PRIMARY PROTECTION Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Amoere)

(Sec/ Cycles) and Location.

(Ampere)

(Sec/ Cycles)

Powered FB2 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770

.012/.72 RMW to RCP Standpipe Fill (8168A)

FB3 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770

.012/.72 RMW to RCP Standpipe Fill (81688)

Supply & Vent Isol.

Accum. N FB2 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 (8875A) 2Supply & Vent 1501.

Accum. N FB6 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 (8875C) 2 FB4 (TC-08A) 3 N/A DC Dist Pnl 2A CKT #13 770

.012/.72 Accum. Line Test 1501.

(8877A)

F08 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 Accum. Line Test Isol.

(8877C)

FB3 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 Accum. Fill Line Isol.

(8878A)

FB7 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770 012/.72 Accum Fill Line Isol (8878C)

FB5 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 Accum. Inject Test Line Isol. (88795)

FB9 (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770

.012/.72 Accum. Inject. Test Line Isol. (8879C)

FB2 (TC-298) 3 N/A DC Dist Pnl 2D CKT #9 770 012/.7e Accum. N2 Supply & Vent Isol (8875B)

FB4 (TC-298) 3 N/A DC Dfst Pn1 2D CKT #9 770 012/.72 Accum. Test Line Isol.

(88778)

FB3 (TC-298) 3 N/A DC Dist Pn1 2D CKT #9 770 012/.72 Accum. Fill Line 1s01.

(88788)

FB5 (TC-298) 3 N/A DC Dist Pn1 2D CKT #9 770 012/.72 Accum. Inject. Test Line Isol (88798)

FBI (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 RCP Seal Leak Off 1s00 (1841A)

FBI (TC-298) 3 N/A DC Dist Pn1 2D CKT #8 770 012/.72 Damper Sol. Vivs. CTMT Purge Isol (3196)

FB9 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 Letdown Orifice Isol. Viv.

(81498) 3/4 8-26 FARLEY - UNIT 2

TABLE 3.8 1 CONTAINMENV PENEVRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Deutce Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered FB2 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770

.012/.72 RCP Seal Leak Off Isol.

(8141C)

FBI (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770

.012/.72 RCP Seal Leak Off Isol.

(8141B)

FBI (TC-06A) 3 N/A DC Dist Pn1 2A CKT #18 770

.012/.72 RCS Alternate Charging Line (8147)

FBI (TC-278) 3 N/A DC Dist Pn1 2D CKT #14 770 012/.72 RCS Normal Charging Line (8146)

FB7 (TC-25B) 3 N/A DC Dist Pn1 2D CKT #7 770 012/.72 Reac. Ves:e1 Leak Off Isol. (8032)

FB2 (TC-258) 3 N/A DC Dist Pn1 2D CKT #7 770

.012/.72 PRZR Rel. Tnk to RMW Supply Isol (4047)

FB8 (TC-27B) 3 N/A DC Dist Pn1 2D CKT #15 770

.012/.72 RCP Seals Wtr By-pass 1 sol. V1v. (8142)

FB5 (TC-278) 3 N/A DC Dist Pn1 2D CKT #15 770 012/.72 Excess L'Down to VCT or RC l

DrnTk (8143)

FB10 (TC-06a) 3 N/A DC Dist Pn1 2A CKT #17 770 012/.72 Letdown Orifice Isol. V1v.

(8149A)

FB8 (TC-06A) 3 N/A DC Dist Pn1 2A CKT #17 770

.012/.72 Letdown Orifice Isol. V1v.

l (8149C)

FBI (TC-08A) 3 N/A DC Dist Pn1 2A CKT #13 770 012/.72 Accum. Test Line Isol. V1v.

(8871)

FB4 (TC-318) 3 N/A DC Dist Pn1 20 CKT #12 770

.012/.72 RCP Comp. Cool (3184)

FBI (TC-09A) 3 N/A DC Dist Pn1 2A CKT #6 770

.012/.72 Excess Letdown Hx Cool Disch.

(3443)

FAN (NBL27028-B) 3 N/A DC Dist Pn1 2E CKT #5 770

.012/.72 SG2A Blowdown (3179C)

FAM (NBL27028-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 SG2B Blowdown (3180C)

FAL (NBL27078-B) 3 N/A DC Dist Pn1 2E CKT #5 770

.012/.72 SG2C Blowdown (3181C)

FAC (NBL27028-B) 3 N/A DC Dist Pn12E CKT #5 770

.012/.72 SG2A Blowdown (3951B)J FAB NBL2702B-B 3

N/A DC Dist Pn1 2E LKT #5 770

.012/.72 SG2B Blowdown 3952B FAA NBL27028-B 3

N/A DC Dist Pn12ii CKT #5 770 012/.72 SG2C Blowdown 3953B)

FAD NBL2702B-B 3

N/A DC Dist Pn1 2E CKT #5 770 012/.72 CVCS Letdown Line Viv.

(39508)

FD (NBL2702A-A) 3 N/A DC Dist Pn1 2B CKT #5 770

.012/.72 CVCS Letdown Line Viv.

(3950A)

FARLEY - UNIT 2 1

TABLE 3.8-1 CONTAINAENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES BACKUP PROTECTION **

PRIMARY PROTECTION Trip

Response

Trip set

Response

D3vice Number Setpoint Time Device humber Point Time System and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered FC (NBL2702A-A) 3 N/A OC Dist Pn128 CKT #5 770 012/.72 SG2A Blowdown (3951A)

FB (NBL2702A-A) 3 N/A DC Dist Pn1 28 CKT #5 770 012/.72 SG2B Blowdown (3952A)

FA (NBL2702A-A) 3 N/A DC Dist Pnl 2B CKT #5 770 012/.72 SG2C Blowdown (3953A)

FK (NBL2702A-A) 3 N/A DC Dist Pn1 28 CKT #5 770 012/.72 SG2A Blowdown (7697A)

SG2CBlowdown(1699A)i SG2B Blowdown (7698A FJ (NBL2702A-A) 3 N/A DC Dist Pol 2B CKT #5 770 012/.72 FH (NBL2707A-A) 3 N/A DC Dist Pnl 28 CKT #5 770 012/.72 FAK (NBL27028-B) 3 N/A DC Ofst Pn1 2E CKT #5 770 012/.72 SG2A Blowdown (7697BJ FAJ (NBL27028-B) 3 N/A DC Dist Pnl 2E CKT #5 770 012/.72 SG2B Blowdown (76988)

FAH (NBL2702B-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 SG2C Blowdown (76998)

FAS (NBL2702B-B) 3 N/A DC Dist Pnl 2E CKT #5 770 012/.72 Press. Stm Space Sampler (3880)

FAR (NBL2702B-B) 3 N/A DC Dist Pn1 2E CKT #5 770 012/.72 Press. Liq Space Sampler (3881)

F/3766(NFSS2607A-A) 3 N/A DC Dist Pol 2C CKT #6 770 012/.72 Accumulator Sampler (3766)

F/3179A(NFSS2607A A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2ABlowdownSampler(3179A[

F/3179B(NFSS2607A-A) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 SG2A Blowdown Sampler (31798J F/3180A(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2B Blowdown Sampler (3180Aj F/3180B(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2B Blowdown Sampler (31808)

F /3181 A(NF SS2607 A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 SG2C Blowdown Sampler (3818AJ F/3181B(NFSS2607A-A) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 SG2C Blowdown Sampler (3181B?

F/3162(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770

.012/.72 Accum. Tank 2A Sampler (3162?

F/3163(NFSS2607A-A) 3 N/A DC Dist Pn1 2C CKT #6 770 012/.72 Accum. Tank 2G Sampler (3163)

F/3164(NFSS2607A-A 3

N/A DC Dist Pnl 2C CKT #6 770 012/.72 Accum. Tank 2C Sampler (3164)

F/3101(NFSS2607B-B 3

N/A DC Dist Pnl 2F CKT #10 770 012/.72 Reac. Coolant Hot Leg (3101)

F/3102(NFSS26078-B 3

N/A DC Dist Pn1 2F CKT #10 770

.012/.72 Reac. Coolant Hot Leg (3102)

FA(NGB25040) 3 N/A DC Dist Pn1 2D CKT #16 770 012/.72 CTMT Sump Disch. (3376)

FA(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770 012/.72 CTMTCoolerDrainsq3395A)

FD(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770

.012/.72 CTMT Cooler Drains I 3395B)

CTMT Cooler Drains ((3395C CTMT Cooler Drains FC(NGB25040) 3 N/A DC Dist Pn1 2G CKT #12 770

.012/.72 33950 FB(NGB25040) 3 N/A DC Dist Pnl 2G CKT #12 770

.012/.72 F/3103(NFSS26078-B) 3 N/A DC Dist Pn1 2C CKT #6 770

.012/.72 PRZR Liquid Sampler (3103 F/3104(NFSS26078-B) 3 N/A DC Dist Pnl 2C CKT #6 770 012/.72 PRZR Liquid Sampler (3104)

F/3765(NFSS2607B-B) 3 N/A DC Dist Pn1 2C CKT #6 770

.012/.72 Reac. Hot Leg Sampler (3765) l I

FARLEY - UNIT 2 3/4 8-28A

l TABLE 3.8 1 CONTAINMENT PrNETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Davice Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered 11.

120VAC Sol. Vivs. Power Fuses FM(NGB2504M) 3 N/A AC Dist Pn1 2J CKT #2 3000

.016/1 Reac. Cavity Cooling (3999A)

FF(NGB25040) 3 N/A AC Dist Pn1 2K CKT #2 3000

.016/1 Reac. Cavity Cooling (39998) 12.

Variable D.C.

Voltage CRDM Fuses (125 V Max)

FU13/A22 10 N/A RC Power Cas FU1/2/3 30 N/A Mechanism #1 Sta. Gripper Group A FU14/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism #2 Sta. Gripper Group A FU15/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism f3 Sta. Gripper Group A FU16/A22 10 N/A RC Power Cab FU1/2/3 30 N/A Mechanism #4 Sta. Gripper Group A FU25/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #1 Sta. Gripper Group B FU26/A23 10 N/A RC power Cab FU4/5/6 30 N/A Mechanism #2 Sta. Gripper Group B FU27/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #3 Sta. Gripper Group B FU28/A23 10 N/A RC Power Cab FU4/5/6 30 N/A Mechanism #4 Sta. Gripper Group B i

FU41/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #1 Sta. Gripper Group C FU42/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #2 Sta. Gripper Group C FU43/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism #3 Sta. Gripper Group C FU44/A24 10 N/A RC Power Cab FU7/8/9 30 N/A Mechanism f4 Sta. Gripper Group C FARLEY - UNIT 2 3/4 8-288

VABLE 3.8-1 CONTAINMENV PENETRAVION CON 00CVOR OVERCURRENT PROTFCTIVE DEVICM PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and Location (Ampere)

(Sec/ Cycles)

Powered FU1/A51 50 N/A 150 N/A Mechanism #1 Lift Group A FU2/A51 50 N/A 150 N/A Mechanism #2 Lift Group A F01/A52 50 N/A 150 N/A Mechanism #3 Lift Group A FU2/A52 50 N/A 150 N/A Mechanism #4 Lift Group A FU1/A53 50 N/A 150 N/A Mechanism #1 Lift Group B FU2/A53 50 N/A Fusible Olsconnect 150 N/A Mechanism #2 Lift Group B FU1/A54 50 N/A Bus Duct Plug-In 150 N/A Mechanism #3 List Group B FU2/A54 50 N/A Unit A-101 150 N/A Mechanism #4 List Group B FU1/A55 50 N/A 150 N/A Mechanism #1 Lift Group C FU2/A55 50 N/A 150 N/A Mechanism #2 Lift Group C FU1/A56 50 N/A 150 N/A Mechanism f3 Lift Group C FU2/A56 50 N/A 150 N/A Mechanism #4 Lift Group C FU21/A25 10 N/A 30 N/A Mechanism #1 Moving Gripper Group A FU22/A25 10 N/A 30 N/A Mechanism #2 Moving Gripper Group A FU23/A25 10 N/A 30 N/A Mechanism f 3 Moving Gripper Group A FU24/A25 10 N/A 30 N/A Mechanism #4 Moving Gripper Group A FU33/A26 10 N/A 30 N/A Mechanism #1 Moving Gripper Group B FU34/A26 10 N/A 30 N/A Mechanism #2 Moving Gripper Group B FU35/A26 10 N/A Fusible Disconnect 30 N/A Mechanism #3 Moving Gripper Bus Duct Plug-In Group B FU36/A26 10 N/A Unit A-102 30 N/A Mechanism f 4 Moving Gripper Group B FU49/A27 10 N/A 30 N/A Mechanism #1 Moving Gripper Group C FU50/A27 10 N/A 30 N/A Mechanism #2 Moving Gripper Group C FU51/A27 10 N/A 30 N/A Mechanism #3 Moving Gripper Group C FU52/A27 10 N/A 30 N/A Mechanism #4 Moving Gripper Group C FARLEY - UNIT 2

[

t

TABLE 3.8-1 CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES PRIMARY PROTECTION BACKUP PROTECTION **

Trip

Response

Trip set

Response

Device Number Setpoint Time Device Number Point Time System and Location (Ampere)

(Sec/ Cycles) and location (Ampere)

(Sec/ Cycles)

Powered 13.

480/277 VAC Lighting Cables LCP-2R N2T51 LOO 3A-N 825

.012/.72 EB09 3300

.1/6 Lighting Panel 2R(N2T51L001A)

LCP-20 N2T51 LOO 3D-N 825

.012/.72 EB09 3300

.1/6 Lighting Panel 20(N2T51L001D LCP-2Q N2751 LOO 38-N 825

.012/.72 EC13 3300

.1/6 Lighting Panel 2Q(N2T51L001B LCP-2P N2T51 LOO 3C-N 825

.012/.72 EC13 3300

.1/6 Lighting Panel 2P(N2T51 LOGIC Receptacle Panel FE-C3Rf 1100

.012/.72 2.'

"2T51 LOO 2A-N) 14 480 VAC 30. H2 Recombiner Power Supply FAL3L 1100

.012/.72 ED10 6600

.18/11 H2 Recombiner HTRS (Q2E17G001A-A)

FB-H6R 1100

.012/.72 EE10 9900

.18/11 H2 Recombiner HTRS (Q2E17G0018-B) i i

j Not required in modes 1-4 May be energized under administrative control when required for maintenance.

This portion of the table is not valid until after the second refueling outage except for the backup protection devices that have been installed prior to startup following the first refueling outage.

FARLEY - UNIT 2 3/4 8-28D

l CONTAINMENT SYSTEMS CONTAINMENT VENTILATION SYSTEM LIMITING CONDITION FOR OPERATION 3.6.1.7 The 48-inch containment purge supply and exhaust isolation valves 6-inch containment I

(CBV-HV-3198A, 31980, 3196, 3197) shall be closed.

The)$

supply and exhaust isolation valves may be open.

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTION:

With one 48-inch containment purge supply and/or one exhaust isolation valve open, close the open valve (s) within one hour or be in at least HOT STAND 8Y within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.7.1 The 48-inch containment purge supply and exhaust isolation valves shall be determined closed at least once per 31 days.

R WnD 4.6.1.7.2 The valve seals of the 48-inch and the J6-inch pwege supply and k

exhaust isolation valves shall be replaced at least once per 5 years.

h FARLEY-UNIT 2 3/4 6-10 L

1 i

TABLE 3.7-4b SAFETY RELATED MECilAi4ICAL SNUBBERS

  • l i

HIGH RADIATION

'm HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT

. E NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE l{

(A or I)

(Yes or No)

(Yes or No)

}'

E AUX. STEAM

-4

)no SS-13247 2

Aux. Bl dg. El. 134' 1" and A

No No j

135' 4 1/4", Room 2241

]'

SS-13250 1

Aux. Bldg. El. 133' 2" A

No No Room 2241

'w SS-13253 2

Aux. Bldg. Ei.133' 9" and A

No No ls 135' O 1/4", Room 2241 u

, L SS-13255 1

Aux. Bldg. El. 133' 3 1/2" A

No No Room 2241 SS-13721 2

Aux. Bldg. El. 101' 8 3/4" A

No No Room 2193 1

1 3

5

]

4 1

1 1

4

. _ =, -

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • l HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i j NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

]g (A or I)

(Yes or No)

(Yes or No) je CHEMICAL AND g VOLUME CONTROL i

[

SS-11894 1

CTMT Bldg. El. 118' 0" I

Yes No NW Quadrant i

i SS-11899 2

CTMT Bldg. El. 117' 8" I

Yes No l

NW Quadrant SS-11902 2

CTMT Bldg. El. 113' 9" I

Yes No j

NW Quadrant y

SS-11974 1

CTMT Bldg. El. 128' 10" I

Yes No SW Quadrant SS-11991 1

CTMT Bldg. El. 128' 8" I

Yes No NE Quadrant SS-12002 1

CTMT Bldg. El. 128' 4" I

Yes No I

NW Quadrant j

SS-12003 1

CTMT Bldg. El. 128' 10" I

Yes No NW Quadrant

)

SS-12010 1

CTMT Bldg. El. 129' 2" I

Yes No

]

NE Quadrant SS-12011 1

CTMT Bldg. El. 133' 0" I

Yes No NE Quadrant l

1

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • l i

j HIGH RADIATION s

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT j

p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE j

Q (A or I)

(Yes or No)

(Yes or No)

I e

i C

i 5

SS-12013 2

CTMT Bldg. El. 133' 0" and I

Yes No j

133' 9 5/8", NW Quadrant

-d I

m SS-12114 1

CTMT Bldg. El. 128' 10" I

Yes No SW Quadrant SS-12146 1

CTMT Bldg. El. 128' 10" I

Yes No SW Quadrant w

s b

SS-12147 i

1 CTMT Bldg. El. 128' 10" I

Yes No l

E SW Quadrant l

SS-12175 1

CTMT Bldg. El. 125' 8 5/16" I

Yes No SW Quadrant SS-12183 1

CTMT Bldg. El. 128' 6" I

Yes No SW Quadrant j

SS-12184 1

CTMT Bldg. El. 128' 6" I

Yes No i

SW Quadrant SS-12185 1

CTMT Bldg. El. 128' 6" I

Yes No j

SW Quadrant SS-12213 1

CTMT Bldg. El. 128' 8" I

Yes No NE Quadrant SS-12231 1

CTMT Bldg. El. 128' 5" I

Yes No j

SE Quadrant l

1 1

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION

^

5 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT P

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No)

~~

i c:

SS-12237 1

CTMT Bldg. El. 128' 5 7/8" I

Yes No SE Quadrant SS-12242 1

CTMT Bldg. El. 128' 9 1/2" I

Yes No SE Quadrant SS-12269 1

CTMT Bldg. El. 129' 8 3/4" I

Yes No NE Quadrant b

S$-12274 1

CTMT Bldg. El. 128' 2 3/4" I

Yes No y

NW Quadrant j k SS-12296 i

1 CTMT Bldg. El. 115' 6" I

Yes No SE Quadrant SS-12346 1

CTMT Bldg. El. 131' 6" I

Yes No SE Quadrant SS-12357 1

CTMT Bldg. El. 124' 8 1/2" I

Yes No l

SE Quadrant SS-12368 1

CTMT Bldg. El. 173' 1 5/16" I

Yes No NW Quadrant SS-12369 2

CTMT Bldg. El. 169' 0 11/16" I

Yes No NW Quadrant SS-12370 2

CTMT Bldg. El. 159' 9 3/16" I

Yes No NW Quadrant

..w.

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION

,i HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

}

(A or I)

(Yes or No)

(Yes or No) e E SS-12372 1

CTMT Bldg. El. 138' 11 5/16" I

Yes No Q

NW Quadrant m

SS-12456 1

CTMT Bldg. El. 115' 10 1/4" I

Yes No SW Quadrant SS-12459 1

CTMT Bldg. El. 114' 10 5/8" I

Yes No 3g SW Quadrant u

-a SS-12473 2

CTMT Bldg. El. 120' 6 1/2" I

Yes No h

SW Quadrant a.

SS-12474 1

CTMT Bldg. El.120' 0" I

Yes No SW Quadrant SS-12476 1

CTMT Bldg. El. 120' 0" I

Yes No SW Quadrant SS-12477 1

CTMT Bldg. El. 120' 0" I

Yes No SW Quadrant SS-12482 1

ClMT Bldg. El. 125' 0" I

Yes No SW Quadrant SS-12483 1

CTMT Bldg. El. 125' 0" I

Yes No SW Quadrant SS-12484 2

CTMT Bldg. El. 125' 0" I

Yes No NW Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER-INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 N'JMB ER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

}

(A or I)

(Yes or No)

(Yes or No) e E

SS-12526 2

CTMT Bldg. El.109' 7" I

Yes No El 112' 0", SE Quadrant to SS-12527 2

CTMT Bldg. El. 111' 4 1/2" I

Yes No 112' 0", SE Quadrant SS-12528 1

CTMT Bldg. El. 112' 0" I

Yes No ya SE Quadrant a

w SS-12373 1

CTMT Bldg. El. 138' 11 5/16" I

Yes No j;

NW Quadrant a

Ss-12543 1

CTMT Bldg. El.108' 6" I

Yes No NE Quadrant 55-12545 1

CTMT Bldg. El. 108' 6" I

Yes No NE Quadrant SS-12547 1

CTMT Bldg. El. 110' 0" I

Yes No NE Quadrant SS-12634 1

CTMT Bldg. El. 122' 10 1/2" I

Yes No SE Quadrant SS-12639 1

CTMT Bldg. El.123' 0" I

Yes No SE Quadrant SS-12648 1

CTMT Bldg. El. 128' 6" I

Yes No SE Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT l

3; NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE i {

(A or I)

(Yes or No)

(Yes or No)

I Ei SS-12677 1

CTMT Bldg. El. 125' 2 1/2" I

Yes No q

SE Quadrant n

SS-12684 1

CTMT Bldg. El. 129' 2" I

Yes No NE Quadrant SS-12685 1

CTMT Bldg. El. 132' 8 3/4" I

Yes No NE Quadrant w2 SS-12686 1

CTMT Bldg. El. 129' 9 1/2" I

Yes No y

g NE Quadrant SS-12687

'l CTMT Bldg. El. 132' 7" I

Yes No NE Quadrant SS-12700 1

CTMT Bldg. El. 122' 10 5/8" I

Yes No SW Quadrant SS-12701 1

CTMT Bldg. El.122' 10 5/8

I Yes No SW Quadrant SS-12703 1

CTMT Bldg. El. 122' 3" I

Yes No SW Quadrant SS-12705 1

CTMT Bldg. El. 122' 3" I

Yes No SW Quadrant SS-12713 1

CTMT Bldg. El. 124' O 15/16" I

Yes No NW Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION y

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No)

SS-12714 1

CTMT Bldg. El.124' O 15/16" I

Yes No

-4 NW Quadrant ro SS-127I6 1

CTMT Bldg. El. 124' O 15/16" I

Yes No NW Quadrant SS-12717 1

CTMT Bldg. El. 124' 0 15/16" I

Yes No NW Quadrant w2 SS-12720 1

CTMT Bldg. El. 122' 6"

I Yes No y

g NW Quadrant c

SS-12721 1

CTMT Bldg. El.123' 3" I

Yes No NW Quadrant SS-12/22 1

CTMT Bldg. El. 123' 3" I

Yes No NW Quadrant SS-12723 1

CTMT Bldg. El.123' 3" I

Yes No NW Quadrant SS-12762 2

CTMT Bldg. El. 107' 11 7/8" I

Yes No and 108' O 1/8", SE Quadrant SS-12763 2

CTMT Bldg. El. 108' 0" I

Yes No SE Quadrant SS-12766 1

CTMT Bldg. El. 121' 7" I

Yes No SE Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No) i SS-12478 1

CfMT Bldg. El. 120' 0" I

Yes No SW Quadrant ro SS-12718 1

CTMT Bldg. El. 122' 6"

I Yes No NW Quadrant SS-12350 1

CTMT Bldg. El. 132' 3 5/8" I

Yes No SE Quadrant w5 SS-12344 1

CTMT Bldg. El. 129' 6" I

Yes No y

g SE Quadrant r

SS-13704 1

Aux. Bldg. El. 136' 3 1/2" A

Yes No Room 2206

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION g

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE g

(A or I)

(Yes or No)

(Yes or No) 1 E COMPONENT COOLING WATER N

SS-12129 1

CTMT Bldg. El. 133' 5 3/4" I

Yes No SW Quadrant SS-12131 1

CTMT Bldg. El. 133' 5 3/4" I

Yes No SW Quadrant SS-12135 1

CTMT Bldg. El. 132' 8 3/4" I

Yes No SW Quadrant SS-12152 1

CTMT Bldg. El. 133' 0" I

Yes No SW Quadrant SS-12154 1

CTMT Bldg. El. 126' 2 5/16" I

Yes No SW Quadrant SS-12155 1

CTMT Bldg. El. 133' 0" I

Yes No SW Quadrant SS-12249 1

CTMT Bldg. El. 133' 8 3/4" I

Yes No NW Quadrant SS-12254 1

CTMT Bldg. El. 126' 2 5/16" I

Yes No SE Quadrant SS-12516 1

CTMT Bldg. El. 132' 3" I

Yes No NW Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • i HIGH RADIATION
32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i E2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE C2 (A or I)

(Yes or No)

(Yes or No) i C

~ 5 SS-12517 1

CTMT 81dg. El. 132' 1" I

Yes No

' -d i

NW Quadrant N

l e

em i

8 m.

4 1

i 3

I J

h

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

-}

(A or I)

(Yes or No)

(Yes or No)

CONTAINMENT SPRAY Z

2CS-R198 2

CTMT Bldg. E1. 273' 0" I

No Yes m

SW Quadrant 2CS-R199 2

CTMT Bldg. E1. 273' 0" I

No Yes SW Quadrant w

2CS-R202 2

CTMT Bldg. El. 255' 0" I

No Yes 3s SE Qt'adrant u

E 2CS-R203 2

CTMT Bldg. E1. 255' 0" I

No Yes NE Quadrar.t 2CS-R254 2

CTMT Bldg. El. 268' 0" I

No Yes SE Quadrant 2CS-R266 2

CTMT Bldg. El. 266' 7" I

No Yes SW Quadrant i

4

m..

--.---. a

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT P!

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE C2 (A or I)

(Yes or No)

(Yes.or No)

't C

  • LIQUID WASTE DISPOSAL SS-12494 1

CTMT Bldg. El.108' 6" I

Yes No SW Quadrant SS-12496 1

CTNT Bldg. El. 108' 1" I

Yes No SW Quadrant b

SS-12521 1

CTMT Bldg. El. 107' 9 7/8" I

Yes No y

NW Quadrant b

SS-12523 2

CTMT Bldg. El. 107' 1" I

Yes No NW Quadrant SS-12533 1

CTMT Bldg. El. 107' 8 3/4" I

Yes No NW Quadrant SS-12534 1

CTMT Bldg. El. 107' 8 3/4" I

Yes No NW Quadrant SS-12659 1

CTMT Bldg. El. 108' 6" I

Yes No SE Quadrant SS-12660 1

CTMT Bldg. El. 107' 6 1/2" I

Yes-No SE Quadrant SS-12662 1

CTMT Bldg. El. 107' 5 1/8" I

Yes No SE Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • 31

??

i C!

HIGH RADIATION HANGER.

NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT

-4 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

N i

SS-12522 1

CTMT Bldg. El. 107' 9 3/4" I

Yes No NW Quadrant 2

SS-13660 1

Aux. Bldg. El. 103' 10" A

No No j

Room 2184 2WP-BR70 1

ClMT Bldg. El. 106' 11 1/4" I

Yes No Se SW Quadrant N

a i

l l

}

.)

I l

4

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • i i

HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT B

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE i p (A or I)

(Yes or No)

(Yes or No)

-c j

!Ej MAIN STEAM Q

j no SS-13177 1

Aux. Bldg. El. 128' 3 1/4" A

No No Room 2241 l

SS-13179 2

Aux. Bldg. El. 127' 9"

A No No Room 2241 SS-13213 1

Au x. Bld g. El. 128' 8" A

No No Room 2241

.y l L.

,y SS-13217 1

Aux. Bldg. El. 128' 8" A

No No i

Room 2241 SS-13242 2

Aux. Bldg. El. 127' 7" A

No No dnd 127' 3 3/4", Room 2241 1

SS-13367 1

Aux. Bldg. El. 127' 3 3/4" A

No No Room 2241 3

SS-13725 1

Au x. Bldg. El.12 /' 8 3/8" A

No No Room 2241 J

SS-14790 1

Aux. Bldg. El. 127' 3 3/4" A

No No Rcom 2241 l

i t

1

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION s

HANGER NUMBER OF SYSTEM SNUBBER INSTALI.E3 ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT NUMBER SNUBBERS ON, LOCATION AND ELEVATION RACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No) i b

SS-15757 1

Aux. Bldg. El. 127' 3 3/4" A

No No Room 2241 m

SS-15772 1

Aux. Bldg. El. 129' 3" A

No No Roo:a 2241 w

b N

8'

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • 4 l

HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT i E NUMBER SNUBBERS ON, LCCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

]'

REACTOR COOLANT 2

Z 2RC-BR1 1

CTMT Bldg. El. 172' 1"

I Yes No NW Quadrant m

i 2RC-R116 2

CTMT Bldg. El. 168' 5" I

Yes No j

NW Quadrant w

2RC-R6 1

CTMT Bldg. El. 174' 1 5/16" I

Yes No 2

c3 NW Quadrant

,u

! I.

2RC-R7 2

CTMT Bldg. El.175' 2" I

Yes No

! if NW Quadrant l

i 2RC-R8 2

CTMT Bldg. El. 161' 1" I

Yes No NW Quadrant 2RC-R9 1

CTMT Bldg. El. 174' 4 1/8" I

Yes No NW Quadrant 2RC-R11 2

CTMT Bldg. E1 171' 1" I

Yes No NW Quadrant 2RC-R18 2

CTMT Bldg. El. 163' 0" I

Yes No NW Quadrant 2RC-R94 1

CTMT Bldg. El. 171' 4 1/8" I

Yes No NW Quadrant i

j i

J TABLE 3.7-4b i

SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 5

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE f

(A or I)

(Yes or No)

(Yes or No)

-e 2RC-R95 1

CTMT Bldg. El. 171' 4 1/8" I

Yes No g;

NW Quadrant 2RC-R98 2

CTMT Bldg. E l.160' 5" I

Yes No NW Quadrant 2RC-R117 1

CTMT Bldg. El. 169' 10" I

Yes No NW Quadrant f( 2RC-R123X 1

CTMT Bldg. El. 169' 10" I

Yes No NW Quadrant jf2RC-R133X 1

CTMT Bldg. Ei. 169' 10" I

Yes No j

NW Quadrant 2RC-R139 2

CTMT Bldg. 21. 167' 10 1/2" I

Yes No NW Quadrant 2RC-R129X 2

CTMT Bldg. El. 159' 5" I

Yes No NW Quadrant 2RC-R128X 2

CTMT Bldg. El. 151' 9 1/2" I

Yes No NW Quadrant l

2RC-R127X 2

CTMT Bldg. El. 146' 0" I

Yes No NW Quadrant 2RC-R10 2

CTMT Bldg. El. 173' 9" I

Yes No NW Quadrant d

v

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 35 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE h

(A or I)

(Yes or No)

(Yes or No) 2RC-R141 1

CTMT Bldg. El. 172' 6 5/8" I

Yes No NW Quadrant a

m 2RC-R144 1

CTMT Bldg. El. 172' 4 1/8" I

Yes No NW Quadrant 2RC-R12 1

CTMT Bldg. El. 171' 4" I

Yes No NW Quadrant 2RC-R113 2

CTMT Bldg. El. 159' 4" I

Yes No y

NW Quadrant

.o.

T 2RC-R147 2

CTMT Bldg. El. 167' 10 1/2" I

Yes No NW Quadrant 2RC-R136 2

CTMT Bldg. El. 167' 10 1/2" I

Yes No NW Quadrant 2RC-R142 1

CTMT Bldg. El. 172' 11 1/2" I

Yes No NW Quadrant 2RC-R132X 2

CTMT Bldg. El. 169' 10" I

Yes No NW Quadrant 2RC-R124X 2

CTMT Bldg. El. 169' 10" I

Yes No NW Quadrant 2RTD-R191 1

CTMT Bldg. El. 127' 1"

I Yes No NE Quadrant

-,as.

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION

"' ?'

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE (A or I)

(Yes or No)

(Yes or No) 2RTD-R190 1

CTMT Bldg. El. 125' 6" I

Yes No E

NE Quadrant

'2kTD-R173 "1

CTMT Bldg. El. 123' 10" I

Yes No

'N SW Quadrant

.s 1

CTMT Bldg. El. 123' 10"u I

~

Yes No T

2RTD-R175 SW Quadrant 2RTD-R172 1

CTMT Bldg. El. 123' 10" I

Yes No y

SW Quadrant

.c.

E 2RTD-R157 1

CTMT Bldg. El. 126' 6" I

Yes Yes NW Quadrant 2RTD-R183 1

CTMT Bldg. El. 124' 3" I

Yes No SE Quadrant 2RTD-R182 1

CTMT Bldg. El. 124' 3"

I Yes No SE Quadrant 2RTD-R187 1

CTMT Bldg. El. 124' 10" I

Yes No NE Quadrant 2RTD-R192 1

CTMT Bldg. El. 126' 8" I

Yes No NE Quadrant 2RTD-R177 1

CTMT Bldg. El. 126' 6" I

Yes No SE Quadrant

.=

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT m

L" NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

}

(A or I)

(Yes or No)

(Yes or No) 2RTD-R180 1

CTMT Bldg. El. 126' 6" I

Yes No E

SE Quadrant

.w N

2RTD-R185 1

CTMT Bldg. El.124' 3" I

Yes No SE Quadrant

~

2RTD-BR9 1

CTMT. Bldg. El. 126' 6" I

Yes No s

SE Quadrant

/

ea

'a 2RTD-BR10 1

CTMT Bldg._El. 124' 3" I

Yes No y

SE Quadrant a#

2RTD-BR2 1

CTMT Bldg. El. 124' 2" I

Yss No NE Quadrant 7

2RTD-BR4' 1

CTMT Bldg. El. 123' 10"

~

I Yes N o '-

SW Quadrant

~

2RTD-BR6 1

CTMT Bldg. El. 124' 10" I

Yes No NE Quadrant 2RTD-BR11 1

CTMT Bldg. El. 126' 6" I

Yes Yes NW Quadrant s

.e.

l 4

A,

~

.4 4

a.

?

TABLE 3.7-4b

' SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION m

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO-REMOVE h

(A or I)

(Yes or No)

(Yes or No)

[

SS-11924 2

CTMT Bldg. El. 128' 6 3/16" and I

Yes No 129' 2 11/16", SW Quadrant z

H N

SS-11933 2

CTMT Bldg. El. 128' 7" and I

Yes No 129' 3 1/2", NW Quadrant SS-11945 2

CTMT Bldg. El. 128' 7 7/8" I

Yes No and 129' 4 3/8", SE Quadrant SS-12536 1

CTMT Bldg. El. 140' 5" I

Yes No y

NW Quadrant a

E SS-12553 1

CTMT Bldg. El. 154' 1 5/8" I

Yes No NW Quadrant SS-12559 1

CTMT Bldg. El. 162' 1 1/16" I

Yes Yes NW Quadrant SS-12754 1

CTMT Bldg. El. 119' 3" I

Yes No SW Quadrant SS-12316 1

CTMT Bldg. El.111' 3" I

Yes No NE Quadrant SS-12324 1

CTMT Bldg. El. 109' 1" I

Yes No SE Quadrant

TABLE 3.7-4b-SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION g

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No) h SAFETY INJECTION 5

-4 2SI-BR7 1

CTMT Bldg. E1. 114' 9" I

Yes No N

SW Quadrant 2SI-BR9 1

CTMT Bldg. El.113' 10" I

Yes No SW Quadrant M.

.a Y

hRESIDUALHEATREMOVAL SS-10319 1

Aux. Bldg. El. 103' 6" A

No

-No Room 2184

i TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION im HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT

( h!

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE lq (A or I)

(Yes or No)

(Yes or No) l E STEAM GENERATOR BLOWDOWN N

SS-12793 1

CTMT Bldg. El. 123' 6" I

Yes-No SE Quadrant SS-12794 1

CTMT Bldg. El. 122' 6" I

Yes No SE Quadrant

}$$

SS-12797 1

CTMT Bldg. El. 123' 6" I

Yes No SE Quadrant

< y SS-12798 1

CTMT Bldg. El. 123' 6" I

Yes No SE Quadrant SS-12799 1

CTMT Bldg. El.128' 1" I

Yes No SE Quadrant i

SS-12802 1

CTMT Bldg. El. 138' 2 1/4" I

Yes No SE Quadrant j

SS-12806 2

CTMT Bldg. El. 151' 0" I

Yes No SE Quadrant S5-12827 2

CTMT Bldg. El. 151' 0" I

Yes No SW Quadrant SS-12830 1

CTMT Bldg. El. 139' 0 1/2" I

Yes No SW Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 3;

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

I E

SS-12833 1

CTMT Bldg. El. 125' 3" I

Yes Yes Z

SW Quadrant i m SS-12834 1

CTMT Bldg. El. 125' 4 1/4" I

Yes Yes l

SW Quadrant SS-12835 1

CTMT Bldg. El.128' 6" I

Yes Yes SW Quadrant

,3 SS-12848 10 CTMT Bldg. El. 134' 1 5/16" I

Yes No y

g SE Quadrant

,x SS-12862 1

CTMT Bldg. El.123' 4" I

Yes No SW Quadrant SS-12863 1

CTMT Bldg. El. 126' 3" I

Yes No SW Quadrant SS-12866 1

CTMT Bldg. El. 122' 6" I

Yes Yes SW Quadrant SS-12867 2

CTMT Bldg. El. 131' 8" I

Yes No SE Quadrant SS-12871 1

CTMT Bldg. El. 124' 9" I

Yes No NE Quadrant SS-12872 1

CTMT Bldg. El. 121' 7"

I Yes No NE Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT 3;

NUMBER SNUBBERS ON, LOCATION AND ELEVATION JNACCESSIBLE DURING SHUTDOWN **

TO REMOVE

{

(A or I)

(Yes or No)

(Yes or No) 1 Ei SS-12877 1

CTMT Bldg. El. 121' 7" I

Yes No Z

NW Quadrant N

SS-12878 1

CTMT Bldg. El. 121' 1" I

Yes No NW Quadrant SS-12882 2

CTMT Bldg. El. 134' 0 9/16" I

Yes No 3a NE Quadrant

=

SS-12883 2

CTMT Bldg. El. 134' 4 1/16" I

Yes No y

g NE Quadrant w

SS-12886 1

CTMT Bldg. El. 151' 0" I

Yes No NE Quadrant SS-12887 1

CTMT Bldg. El. 151' 0"

I Yes No NE Quadrant SS-12888 2

CTMT Bldg. El. 151' 0" I

Yes Yes NE Quadrant SS-12889 1

CTMT Bldg. El. 151' 0" I

Yes Yes NE Quadrant SS-12891 1

CTMT Bldg. El. 150' 0" I

Yes Yes l

NE Quadrant SS-12896 1

CTMT Bldg. El. 128' 4" I

Yes No NE Quadrant

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT E

NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

}

(A or I)

(Yes or No)

(Yes or No)

Ei SS-12897 1

CTMT Bldg. El. 128' 4" I

Yes No y

NE Quadrant ro SS-12899 1

CTMT Bldg. El. 131' 7 1/16" I

Yes No NE Quadrant SS-12900 2

CTMT Bldg. El. 144' 0" I

Yes Yes NE Quadrant a

SS-12906 1

CTMT Bldg. El. 106' O 1/4" I

Yes No y

g SW Quadrant N

SS-12940 1

CTMT Bldg. El. 127' 4" I

Yes No SW Quadrant SS-12942 2

CTMT Bldg. El. 127' 4" I

Yes Yes SW Quadrant SS-12944 3

CTMT Bldg. El.127' 4" I

Yes Yes SW Quadrant SS-12946 1

CTMT Bldg. El. 127' 4" I

Yes No SW Quadrant SS-12951 3

CTMT Bldg. El. 128' 4 1/2" I

Yes Yes SW Quadrant SS-13536 3

Aux. Bldg. El. 134' 9 1/4" A

No No 135' 0", Raom 2237

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION 32 HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT p2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE Q

(A or I)

(Yes or No)

(Yes or No)

I SS-13538 3

Aux. Bldg. El. 130' 9"

A No No

-i Room 2237 m

SS-13546 3

Aux. Bldg. El. 134' 6" A

No No Room 2188 SS-13810 1

Aux. Bldg. El. 136' 3" A

No No Room 2608 u,

-1 SS-13812 1

Aux. Bldg. El. 130' 9 1/2" A

No No

.y 1,

Room 2608 8

SS-13819 1

Aux. Bldg. El. 135' 2 1/4" A

Yes No Room 2223 SS-13826 3

Aux. Bldg. El. 133' 0" A

Yes No Room 2223 SS-15064 1

Aux. Bldg. El. 132' 10 5/8" A

No No Room 2609 SS-15065 1

Aux. Bldg. El. 132' 10 5/8" A

No No Room 2609 SS-15066 1

Aux. Bldg. El. 132' 10 5/8" A

No No Room 2609 SS-15067 1

Aux. Bldg. El. 132' 5 3/8" A

No No Room 2609

TABLE 3.7-4b SAFETY RELATED MECHANICAL SNUBBERS

  • HIGH RADIATION s

HANGER NUMBER OF SYSTEM SNUBBER INSTALLED ACCESSIBLE OR ZONE ESPECIALLY DIFFICULT F2 NUMBER SNUBBERS ON, LOCATION AND ELEVATION INACCESSIBLE DURING SHUTDOWN **

TO REMOVE

[]

(A or I)

(Yes or No)

(Yes or No) i b

SS-15068 1

Aux. Bldg. El. 132' 5 3/8" A

No No Room 2609 ro SS-15069 1

Aux. Bldg. El. 132' 5 3/8" A

No No Room 2609 kt i

a u

b i

i l

Snubbers may be added to safety related systems without prior License Amendment to Table 3.7-4b provided that a revision to Table 3.7-4b is included with the next License Amendment request.

Modifications to this column due to changes in high radiation areas may be made without prior License Amendment provided that a revision to Table 3.7-4b is included with the next License Amendment request.

t i