KANSAS GAS AND ELECTRIC COMPANY T>-E ELE cts *C COMPANY GLENN L MOESTER vec t ** ts+0taeY souct e as August 22, 1983 Mr. W.C. Seidle , Chief                                                 gg                       [p q Reactor Projects Branch 2                                                             . - 1._ _f    all U.S. Nuclear Regulatory Commission                                           s !                      I Region IV 611 Ryan Plaza Drive, Suite 1000 l[}' , _ _ _, g g n3
KANSAS GAS AND ELECTRIC COMPANY T>-E ELE cts *C COMPANY GLENN L MOESTER vec t ** ts+0taeY souct e as August 22, 1983 Mr. W.C. Seidle, Chief gg
                                                                                                                                )
[p q Reactor Projects Branch 2
Arlington, Texas           76011                                           i ilj KMLNRC 83-109 Re:     Docket No. STN 50-482 Ref: 1) Interim Report KMLNRC 83-026 dated 3/17/83 from GLKoester, KG&E, to WCSeidle, NRC
. - 1.__f all U.S. Nuclear Regulatory Commission I
: 2) Interim Report KMLNRC 83-065 dated 6/3/83 f rom GLKoes ter , KG&E , to WCSeidle , NRC Subj: Withdrawal of Potential 10CFR50.55 (e) - Workmanship on Swagelok Fittings
s Region IV l[}', _ _ _, g g 611 Ryan Plaza Drive, Suite 1000 n3
)
ilj Arlington, Texas 76011 i
KMLNRC 83-109 Re:
Docket No. STN 50-482 Ref: 1) Interim Report KMLNRC 83-026 dated 3/17/83 from GLKoester, KG&E, to WCSeidle, NRC
: 2) Interim Report KMLNRC 83-065 dated 6/3/83 f rom GLKoes ter, KG&E, to WCSeidle, NRC Subj: Withdrawal of Potential 10CFR50.55 (e) - Workmanship on Swagelok Fittings


==Dear Mr. Seidle:==
==Dear Mr. Seidle:==
 
This letter withdraws the potential 10CFR50.55(e) report concerning work-manship on Swagelok Fittings and tubing installation at the Wolf Creek j
This letter withdraws the potential 10CFR50.55(e) report concerning work-manship on Swagelok Fittings and tubing installation at the Wolf Creek j                       job site. This matter was initially reported on February 5,1983, with suppleme ital information provided in References 1) and 2).
job site.
I                       As stated in Reference 2) , information obtained from inspections and l
This matter was initially reported on February 5,1983, with suppleme ital information provided in References 1) and 2).
I As stated in Reference 2), information obtained from inspections and l
testing of various tubing installations was transmitted to the Architect /
testing of various tubing installations was transmitted to the Architect /
Engineer (A/E) for evaluation. The A/E has now completed the e valuation and determined that the tubing installation in question does not represent a safety concern and would not adversely affect safety of operations.
Engineer (A/E) for evaluation. The A/E has now completed the e valuation and determined that the tubing installation in question does not represent a safety concern and would not adversely affect safety of operations.
Therefore, KG&E has concluded that this matter is not reportable pursuant to 10CFR50.55(e).
Therefore, KG&E has concluded that this matter is not reportable pursuant to 10CFR50.55(e).
If you have any questions concerning this subject, please contact me or Mr. Otto Maynard of my staff.
If you have any questions concerning this subject, please contact me or Mr. Otto Maynard of my staff.
Yours very truly,
Yours very truly, gl b
                                                                                        '                          b ffy       c   gl GLK:bb cc: RCDeYoung HRoberds/WSchum                                                                                         j 8308300366 830822                                                                                 -
ffy c
DR ADOCK 05000482                                                                             LL ~ 17 PDR                                                                               (g 201 N. Market -Wichita, Kansas - Marl Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 2616451}}
GLK:bb cc: RCDeYoung HRoberds/WSchum j
8308300366 830822 DR ADOCK 05000482 LL ~ 17 PDR
( g 201 N. Market -Wichita, Kansas - Marl Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 2616451}}

Latest revision as of 22:24, 14 December 2024

Final Deficiency Rept Re Workmanship on Swagelok Fittings & Tubing Installation.Initially Reported on 830205.Tubing Installation Not Safety Concern.Item Determined Not Reportable Per 10CFR50.55e
ML20080D344
Person / Time
Site: Wolf Creek 
Issue date: 08/22/1983
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, KMLNRC-83-109, NUDOCS 8308300366
Download: ML20080D344 (1)


Text

-_

KANSAS GAS AND ELECTRIC COMPANY T>-E ELE cts *C COMPANY GLENN L MOESTER vec t ** ts+0taeY souct e as August 22, 1983 Mr. W.C. Seidle, Chief gg

[p q Reactor Projects Branch 2

. - 1.__f all U.S. Nuclear Regulatory Commission I

s Region IV l[}', _ _ _, g g 611 Ryan Plaza Drive, Suite 1000 n3

)

ilj Arlington, Texas 76011 i

KMLNRC 83-109 Re:

Docket No. STN 50-482 Ref: 1) Interim Report KMLNRC 83-026 dated 3/17/83 from GLKoester, KG&E, to WCSeidle, NRC

2) Interim Report KMLNRC 83-065 dated 6/3/83 f rom GLKoes ter, KG&E, to WCSeidle, NRC Subj: Withdrawal of Potential 10CFR50.55 (e) - Workmanship on Swagelok Fittings

Dear Mr. Seidle:

This letter withdraws the potential 10CFR50.55(e) report concerning work-manship on Swagelok Fittings and tubing installation at the Wolf Creek j

job site.

This matter was initially reported on February 5,1983, with suppleme ital information provided in References 1) and 2).

I As stated in Reference 2), information obtained from inspections and l

testing of various tubing installations was transmitted to the Architect /

Engineer (A/E) for evaluation. The A/E has now completed the e valuation and determined that the tubing installation in question does not represent a safety concern and would not adversely affect safety of operations.

Therefore, KG&E has concluded that this matter is not reportable pursuant to 10CFR50.55(e).

If you have any questions concerning this subject, please contact me or Mr. Otto Maynard of my staff.

Yours very truly, gl b

ffy c

GLK:bb cc: RCDeYoung HRoberds/WSchum j

8308300366 830822 DR ADOCK 05000482 LL ~ 17 PDR

( g 201 N. Market -Wichita, Kansas - Marl Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 2616451