(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
Line 16: Line 16:
| event date = 01/02/2004 02:30 CST
| event date = 01/02/2004 02:30 CST
| last update date = 01/02/2004
| last update date = 01/02/2004
| title = Failure Of Autoclave Isolation System
| title = Failure of Autoclave Isolation System
| event text = At 0230 on 01-02-04 the Plant Shift Superintendent (PSS) was notified of a failure of the C-360 #3 Autoclave High Pressure Isolation System.  Steam was observed leaking from the autoclave head-to-shell interface between the eleven and one o'clock position shortly after initiating a cylinder heat cycle.  At the time of discovery, the autoclave was in TSR [Technical Safety Requirements] mode 5 and the High Pressure Isolation System was required to be operable while in this mode.  This system is designed to provide containment of the autoclave and prevent an external release of UF6 during a system breach while heating a UF6 cylinder.  The PSS declared the system inoperable and TSR LCO 2.1.3.1.C1 actions were implemented to remove the autoclave from service and place it in Mode 2, "Out of Service".  The event is reportable as a 24 hour event, as required by 10 CFR 76.120(c)(2)(i); An event in which equipment is disabled or fails to function as designed when the equipment is required by a TSR to prevent releases, prevent exposures to radiation and radioactive materials exceeding specified limits, mitigate the consequences of an accident, or restore this facility to a pre-established safe condition after an accident.  The equipment was required by TSR to be available and operable and no redundant equipment was available to perform the required safety function.
| event text = At 0230 on 01-02-04 the Plant Shift Superintendent (PSS) was notified of a failure of the C-360 #3 Autoclave High Pressure Isolation System.  Steam was observed leaking from the autoclave head-to-shell interface between the eleven and one o'clock position shortly after initiating a cylinder heat cycle.  At the time of discovery, the autoclave was in TSR [Technical Safety Requirements] mode 5 and the High Pressure Isolation System was required to be operable while in this mode.  This system is designed to provide containment of the autoclave and prevent an external release of UF6 during a system breach while heating a UF6 cylinder.  The PSS declared the system inoperable and TSR LCO 2.1.3.1.C1 actions were implemented to remove the autoclave from service and place it in Mode 2, "Out of Service".  The event is reportable as a 24 hour event, as required by 10 CFR 76.120(c)(2)(i); An event in which equipment is disabled or fails to function as designed when the equipment is required by a TSR to prevent releases, prevent exposures to radiation and radioactive materials exceeding specified limits, mitigate the consequences of an accident, or restore this facility to a pre-established safe condition after an accident.  The equipment was required by TSR to be available and operable and no redundant equipment was available to perform the required safety function.
The Senior NRC Resident Inspector has been notified of this event.
The Senior NRC Resident Inspector has been notified of this event.

Revision as of 21:24, 1 March 2018

ENS 40423 +/-
Where
Paducah Gaseous Diffusion Plant
Paducah, Kentucky (NRC Region 2)
License number: Gdp-1
Reporting
10 CFR 76.120(c)(2)
Time - Person (Reporting Time:+1.55 h0.0646 days <br />0.00923 weeks <br />0.00212 months <br />)
Opened: Tony Hudson
10:03 Jan 2, 2004
NRC Officer: Mike Ripley
Last Updated: Jan 2, 2004
40423 - NRC Website