ENS 40664: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 04/10/2004 11:50 PDT
| event date = 04/10/2004 11:50 PDT
| last update date = 04/10/2004
| last update date = 04/10/2004
| title = Manual Reactor Trip Due To Loss Of Both Main Feedwater Pumps
| title = Manual Reactor Trip Due to Loss of Both Main Feedwater Pumps
| event text = San Onofre Unit 2 was manually tripped from 97% power due to the loss of feed water pumps.  After both feedwater pumps tripped, the operators manually tripped the reactor.  Both trains of the emergency feed water system actuated as expected due to the initial power level.  The plant is stable at NOP/NOT.  The cause of the feed water pump trips is being evaluated.  All control rods fully inserted and all safety systems worked properly.  The steam generators are discharging steam to the main condenser using the turbine bypass valves.  AFW pumps are running to maintain steam generator water levels.
| event text = San Onofre Unit 2 was manually tripped from 97% power due to the loss of feed water pumps.  After both feedwater pumps tripped, the operators manually tripped the reactor.  Both trains of the emergency feed water system actuated as expected due to the initial power level.  The plant is stable at NOP/NOT.  The cause of the feed water pump trips is being evaluated.  All control rods fully inserted and all safety systems worked properly.  The steam generators are discharging steam to the main condenser using the turbine bypass valves.  AFW pumps are running to maintain steam generator water levels.
The Licensee notified the NRC Resident Inspector.
The Licensee notified the NRC Resident Inspector.

Latest revision as of 22:23, 1 March 2018

ENS 40664 +/-
Where
San Onofre Southern California Edison icon.png
California (NRC Region 4)
Reporting
10 CFR 50.72(b)(2)(iv)(B), RPS Actuation

10 CFR 50.72(b)(3)(iv)(A), System Actuation
Time - Person (Reporting Time:+-1.93 h-0.0804 days <br />-0.0115 weeks <br />-0.00264 months <br />)
Opened: Joel Barnett
16:54 Apr 10, 2004
NRC Officer: Bill Gott
Last Updated: Apr 10, 2004
40664 - NRC Website
Loading map...