<e BALTIMORE G AS AND ELECTRIC COMPANY l | |||
P.O. B O x 14 7 5 | |||
l | ) | ||
B A LTIMOR E, M A R YL A N D 212o3 NUCLEAR POWER DEPARTMENT CALVERT CLIFFS NUCLEAR POWER PL ANT LUSB*, MARYLAND 20657 October 15,1985 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, DC 20555 ATTENTION: | |||
Mr. David H. Jaffe, Project Manager Operating Reactor Branch #3 | |||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 27: | Line 27: | ||
==REFERENCE:== | ==REFERENCE:== | ||
NRC Letter from H. | NRC Letter from H. | ||
R. | |||
Denton, to A. E. Lundvall, J r., | |||
dated September 18,1985, with enclosed Safety Evaluation Gentlemen: | |||
This is to clarify the alternate examinations specified in the referenced letter's enclosed Safety Evaluation per a recent telephone conference. | This is to clarify the alternate examinations specified in the referenced letter's enclosed Safety Evaluation per a recent telephone conference. | ||
Your letter correctly stated our proposed alternate examinations as: | Your letter correctly stated our proposed alternate examinations as: | ||
The reactor coolant pumps will be examined in accordance with ASME Code Section XI 1974 edition with addenda through Summer 1975, Article IWA-5240 during the hydrostatic test. One pump per unit will receive a visual inspection of the casing exterior surface in accordance with Article IWA-2210; this examination will not be | ... (1) pump interior examination to the extent practical in the event that a pump is disassembled, (2) hydrostatic testing, ~and (3) surface examination of one reactor coolant pump's casing welds, per unit, and a 100% visual examination of this pump's exterior.... " Page 6 of the enclosed Safety Evaluation restated part of our proposed examinations incorrectly | ||
1m 851010005685ggg7 | "... a visual inspection of the casing exterior surface will be performed during the as: | ||
hydrostatic test of the reactor coolant system...." | |||
The reactor coolant pumps will be examined in accordance with ASME Code Section XI 1974 edition with addenda through Summer 1975, Article IWA-5240 during the hydrostatic test. | |||
One pump per unit will receive a visual inspection of the casing exterior surface in accordance with Article IWA-2210; this examination will not be d | |||
performed during the hydrostatic test. | |||
1m 851010005685ggg7 | |||
:[ | :[ | ||
G | PDR ADOCK PDR G | ||
l | l i | ||
i | Mr. David H. Jaffe October 15,1985 Page 2 | ||
Mr. David H. Jaffe | + | ||
October 15,1985 Page 2 | |||
1 Should you have further questions regarding this matter, please do not hesitate to contact us. | 1 Should you have further questions regarding this matter, please do not hesitate to contact us. | ||
Very truly yours, i | Very truly yours, i | ||
A l | A P | ||
J l | |||
R. E. Denton General Supervisor-Training & Technical Services RED /BCR/gla cc: D. A. Brune, Esquire G. F. Trowbridge, Esquire 1 | |||
T. Foley 1 | |||
4 l | 4 l | ||
s L | s L | ||
.+}} | |||
Latest revision as of 08:04, 12 December 2024
| ML20133H651 | |
| Person / Time | |
|---|---|
| Site: | Calvert Cliffs |
| Issue date: | 10/15/1985 |
| From: | Denton R BALTIMORE GAS & ELECTRIC CO. |
| To: | Jaffe D Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8510180056 | |
| Download: ML20133H651 (2) | |
Text
'
<e BALTIMORE G AS AND ELECTRIC COMPANY l
P.O. B O x 14 7 5
)
B A LTIMOR E, M A R YL A N D 212o3 NUCLEAR POWER DEPARTMENT CALVERT CLIFFS NUCLEAR POWER PL ANT LUSB*, MARYLAND 20657 October 15,1985 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, DC 20555 ATTENTION:
Mr. David H. Jaffe, Project Manager Operating Reactor Branch #3
SUBJECT:
Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Inservice Inspection Program
REFERENCE:
NRC Letter from H.
R.
Denton, to A. E. Lundvall, J r.,
dated September 18,1985, with enclosed Safety Evaluation Gentlemen:
This is to clarify the alternate examinations specified in the referenced letter's enclosed Safety Evaluation per a recent telephone conference.
Your letter correctly stated our proposed alternate examinations as:
... (1) pump interior examination to the extent practical in the event that a pump is disassembled, (2) hydrostatic testing, ~and (3) surface examination of one reactor coolant pump's casing welds, per unit, and a 100% visual examination of this pump's exterior.... " Page 6 of the enclosed Safety Evaluation restated part of our proposed examinations incorrectly
"... a visual inspection of the casing exterior surface will be performed during the as:
hydrostatic test of the reactor coolant system...."
The reactor coolant pumps will be examined in accordance with ASME Code Section XI 1974 edition with addenda through Summer 1975, Article IWA-5240 during the hydrostatic test.
One pump per unit will receive a visual inspection of the casing exterior surface in accordance with Article IWA-2210; this examination will not be d
performed during the hydrostatic test.
1m 851010005685ggg7
- [
l i
Mr. David H. Jaffe October 15,1985 Page 2
+
1 Should you have further questions regarding this matter, please do not hesitate to contact us.
Very truly yours, i
A P
J l
R. E. Denton General Supervisor-Training & Technical Services RED /BCR/gla cc: D. A. Brune, Esquire G. F. Trowbridge, Esquire 1
T. Foley 1
4 l
s L
.+