<e BALTIMORE G AS AND ELECTRIC COMPANY l

P.O. B O x 14 7 5

)

B A LTIMOR E, M A R YL A N D 212o3 NUCLEAR POWER DEPARTMENT CALVERT CLIFFS NUCLEAR POWER PL ANT LUSB*, MARYLAND 20657 October 15,1985 U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, DC 20555 ATTENTION:

Mr. David H. Jaffe, Project Manager Operating Reactor Branch #3

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Inservice Inspection Program

REFERENCE:

NRC Letter from H.

R.

Denton, to A. E. Lundvall, J r.,

dated September 18,1985, with enclosed Safety Evaluation Gentlemen:

This is to clarify the alternate examinations specified in the referenced letter's enclosed Safety Evaluation per a recent telephone conference.

Your letter correctly stated our proposed alternate examinations as:

... (1) pump interior examination to the extent practical in the event that a pump is disassembled, (2) hydrostatic testing, ~and (3) surface examination of one reactor coolant pump's casing welds, per unit, and a 100% visual examination of this pump's exterior.... " Page 6 of the enclosed Safety Evaluation restated part of our proposed examinations incorrectly

"... a visual inspection of the casing exterior surface will be performed during the as:

hydrostatic test of the reactor coolant system...."

The reactor coolant pumps will be examined in accordance with ASME Code Section XI 1974 edition with addenda through Summer 1975, Article IWA-5240 during the hydrostatic test.

One pump per unit will receive a visual inspection of the casing exterior surface in accordance with Article IWA-2210; this examination will not be d

performed during the hydrostatic test.

1m 851010005685ggg7

[

PDR ADOCK PDR G

l i

Mr. David H. Jaffe October 15,1985 Page 2

+

1 Should you have further questions regarding this matter, please do not hesitate to contact us.

Very truly yours, i

A P

J l

R. E. Denton General Supervisor-Training & Technical Services RED /BCR/gla cc: D. A. Brune, Esquire G. F. Trowbridge, Esquire 1

T. Foley 1

4 l

s L

.+