ENS 49337: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 08/02/2013 CDT
| event date = 08/02/2013 CDT
| last update date = 09/10/2013
| last update date = 09/10/2013
| title = Part 21 Report - Improper Dedication Of Actuator Parts
| title = Part 21 Report - Improper Dedication of Actuator Parts
| event text = Fisher issued an information notice (FIN 2013-03) to alert Palo Verde Nuclear Generating Station of an issue associated with two valve assemblies supplied to PVNGS by Fisher.  Fisher determined that the valves were provided with actuator parts that were not properly processed per active valve requirements specified in the purchase order.  Specifically, Fisher provided commercial grade parts instead of commercial grade dedicated items.
| event text = Fisher issued an information notice (FIN 2013-03) to alert Palo Verde Nuclear Generating Station of an issue associated with two valve assemblies supplied to PVNGS by Fisher.  Fisher determined that the valves were provided with actuator parts that were not properly processed per active valve requirements specified in the purchase order.  Specifically, Fisher provided commercial grade parts instead of commercial grade dedicated items.
Arrangements have been made with PVNGS to retrofit the correctly processed parts on the subject valves.
Arrangements have been made with PVNGS to retrofit the correctly processed parts on the subject valves.

Latest revision as of 21:00, 1 March 2018

ENS 49337 +/-
Where
Fisher Controls International, Llc
Marshalltown, Iowa (NRC Region 3)
Organization: Emerson Process Management
Reporting
10 CFR 21.21(d)(3)(i), Failure to Comply or Defect
Time - Person (Reporting Time:+944.6 h39.358 days <br />5.623 weeks <br />1.294 months <br />)
Opened: George Baitinger
13:36 Sep 10, 2013
NRC Officer: Donald Norwood
Last Updated: Sep 10, 2013
49337 - NRC Website