ENS 52935
ENS Event | |
---|---|
05:00 Aug 28, 2017 | |
Title | Part 21 Report - Flow Scanner 6.6 Code Error |
Event Description | The following information was received via e-mail:
Fisher Information Notice: FIN 2017-04: Erroneous Rotary Seating Torque Calculation in FlowScanner Software This Fisher Information Notice (FIN) applies only to the equipment identified in Appendix A, which lists serial numbers and order numbers that were delivered to customers. Specifically, it applies to FlowScanner 6.6 (build 6.6.000.29) and 6.6 SP1 (build 6.6.000.67). Appendix B of this document includes a decision tree to help customers further determine if this FIN applies to any work performed. The purpose of this FIN is to alert affected customers that, as of 29 June 2017, Fisher Controls International LLC (Fisher) became aware of a situation which may affect the performance of the aforementioned equipment. Fisher is informing affected customers of this circumstance in accordance with Section 21.21 (b) of 10 CFR 21. In the process of updating a customer's older FlowScanner software version to 6.6.000.67 (SP1), the customer performed additional software acceptance validation and discovered a discrepancy between the two software versions when calculating Seating Torque values for Rotary Valve assemblies with Lever Arm linkage type. An equation in 6.6.000.67 is the cause for the discrepancy. This equation was incorrectly written in code with a lack of an additional set of parentheses to order the execution of mathematical functions correctly. In code writing, this is considered a typographical error. When FlowScanner 6.6 was in development, there was a need to incorporate a new actuator design into the FlowScanner torque calculations. Because of the design of this actuator, the torque equations and configuration database in FlowScanner required modification. This code was modified on 7 November 2012. FlowScanner 6.6 (build 6.6.000.29) and 6.6 SP1 (build 6.6.000.67) were released subsequent this date and contained the erroneous calculation. Shipments of software were stopped on 30 July 2017 and no shipments took place between 29 June 2017 and 30 July 2017. This code was not transferred to the QUIKLOOK FS software utilized on the QUIKLOOK 3-FS diagnostic system. Thus, this error does not extend into QUIKLOOK FS software. The equation has been corrected and full-installation CDs will be ready for distribution to affected customers by 1 December 2017. In addition, a Corrective Action Request (CAR 2017-009) has been initiated by Fisher to prevent reoccurrence of this issue. Additionally, Software Error Notice SEN17-01 was created and released to affected customers on 2 August 2017. Fisher requests that the recipient of this FlN review it and take appropriate action in accordance with 10 CFR 21. If there are any technical questions or concerns, please contact: Guy Scaggs Quality Manager Emerson Automation Solutions Fisher Lifecycle Services 757 Old Clemson Rd Columbia, SC 29229 Phone: (803) 462-6203 Guy.Scaggs@Emerson.com Appendix A - List of Affected Equipment Table 1: FlowScanner 6000 Safety Related Orders with V6.6 Supplied FISHER CONTROLS INTERNATIONAL - Marshalltown EXELON POWERLABS LLC - COATESVILLE FLORIDA POWER AND LIGHT CO - SEABROOK STATION NEXTERA ENERGY - DUANE ARNOLD Table 2: Stand Alone Software Orders- Safety Related V6.6 DOMINION NUCLEAR CONNECTICUT INC. - Millstone Power Station OMAHA PUBLIC POWER DISTRICT - Fort Calhoun Nuclear Station FISHER CONTROLS INTERNATIONAL LLC - Fisher Controls International LLC SOUTHERN CO - Southern Company NEXTERA ENERGY POINT BEACH LLC - Point Beach Nuclear Plant Appendix B - Decision Tree for Applicability How to determine if this FIN applies to you: Are you using FlowScanner 6.6 or 6.6 SP1? If 'YES', do you use FlowScanner 6.6 or 6.6 SP1 to complete a 'Dynamic Scan' test on rotary valves with lever arm linkages? Such as any TAG configured with 'LEVER ARM' in the 'Linkage Type' field for example Fisher Types 1052, 2052, and 1061 If 'YES', do you manually select the significant points for Seating Torque and Break Out Torque from the 'Dynamic Scan' test? If 'YES', do you use the Seating Torque result value provided by FlowScanner for any qualification, validation, or acceptance activities? If you answered 'NO' to ALL of these questions, this software error does not affect your usage of the FlowScanner 6.6 or 6.6 SP1 software. If you answered 'YES' to ANY of the questions, further evaluation of the affected Seating Torque test results may be necessary. A workaround has been issued to affected customers. |
Where | |
---|---|
Fisher Controls International, Llc Marshalltown, Iowa (NRC Region 3) | |
Organization: | Fisher Controls International, Llc |
Reporting | |
10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
Time - Person (Reporting Time:+12.75 h0.531 days <br />0.0759 weeks <br />0.0175 months <br />) | |
Opened: | George Baitinger 17:45 Aug 28, 2017 |
NRC Officer: | Mark Abramovitz |
Last Updated: | Aug 28, 2017 |
52935 - NRC Website | |
Fisher Controls International, Llc with 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
WEEKMONTHYEARENS 529352017-08-28T05:00:00028 August 2017 05:00:00
[Table view]10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Flow Scanner 6.6 Code Error ENS 518102016-01-22T05:00:00022 January 2016 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Plug/Stem Assembly ENS 517002016-01-05T06:00:0005 January 2016 06:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Improper Accessory Mounting Bracket Processing ENS 506352014-10-06T05:00:0006 October 2014 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Type 67 Afr Regulators with Improperly Dedicated Diaphragm Valve Seats ENS 496642013-12-17T06:00:00017 December 2013 06:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 - Fisher Type 377 Trip Valves Not Processed as Required ENS 493372013-08-02T05:00:0002 August 2013 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report - Improper Dedication of Actuator Parts ENS 484922012-11-07T06:00:0007 November 2012 06:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Part 21 Report- Commercial Grade Dedication Not Properly Applied to Butterfly Valves ENS 478462012-04-18T05:00:00018 April 2012 05:00:00 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect Fisher Type 9500 Butterfly Valves Contain Non Dedicated Parts 2017-08-28T05:00:00 | |