| title = Safe Shutdown Analysis Reveals Noncompliance For A Fire Outside Diesel Room
| title = Safe Shutdown Analysis Reveals Noncompliance for a Fire Outside Diesel Room
| event text = During the performance of a focused area self assessment (FASA) for the Clinton Power Station Fire Protection Program, the FASA team identified a noncompliance with the Safe Shutdown Analysis for a fire outside the Diesel Generator (DG) rooms (i.e., Fire Zone CB-1e, CB-1f, CB-2 and CB-4).  The CO2 panels for each DG train are all located in the same area outside the DG engine bay rooms (i.e., 737' Control Building) and a fire in this area could cause fire damage to all three CO2 panels and/or wiring such that a trip (short) could be initiated to all three DG Ventilation (VD) fans. Loss of the VD fans (1VD01CA, B and C) results in loss of cooling in the DG rooms and ultimately loss of the diesels.  This constitutes an Unanalyzed Condition that Significantly Affects Plant Safety.
| event text = During the performance of a focused area self assessment (FASA) for the Clinton Power Station Fire Protection Program, the FASA team identified a noncompliance with the Safe Shutdown Analysis for a fire outside the Diesel Generator (DG) rooms (i.e., Fire Zone CB-1e, CB-1f, CB-2 and CB-4).  The CO2 panels for each DG train are all located in the same area outside the DG engine bay rooms (i.e., 737' Control Building) and a fire in this area could cause fire damage to all three CO2 panels and/or wiring such that a trip (short) could be initiated to all three DG Ventilation (VD) fans. Loss of the VD fans (1VD01CA, B and C) results in loss of cooling in the DG rooms and ultimately loss of the diesels.  This constitutes an Unanalyzed Condition that Significantly Affects Plant Safety.
Compensatory measures are in-place that will allow these VD trips to be overridden and the VD fans to be restarted from the Main Control Room.
Compensatory measures are in-place that will allow these VD trips to be overridden and the VD fans to be restarted from the Main Control Room.

Latest revision as of 22:00, 1 March 2018

ENS 49373 +/-
Where
Clinton Constellation icon.png
Illinois (NRC Region 3)
Reporting
10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition