Line 16: Line 16:
| event date = 02/05/2014 10:30 CST
| event date = 02/05/2014 10:30 CST
| last update date = 02/05/2014
| last update date = 02/05/2014
| title = Agreement State Report - Malfunctioning Source Shutter Failed To Close
| title = Agreement State Report - Malfunctioning Source Shutter Failed to Close
| event text = The following information was received via facsimile from the State of Nebraska:
| event text = The following information was received via facsimile from the State of Nebraska:
The Nebraska Department of Health and Human Services was notified by a representative of the Omaha Public Power District that a Kay Ray fixed gauge Model Number 7080 source shutter failed to close.  The device contains approximately 25.5 millicuries of Cesium-137.  The gauge is mounted between two fly ash hoppers approximately 20 feet off of the floor. The source closure mechanism on the gauge is connected to a handle located at floor level by a flexible cable.  The closure cable is secured so that when the floor handle is operated, the control cable slides inside of the sheath opening/closing the shutter. The shutter closure cable became loose where the sheath attaches to the source closure mechanism which prevented the shutter from closing. The licensee disconnected the lower part from the cable and the on/off handle. By holding on to the lower part of the sheath and sliding the internal cable, the licensee was able to close the shutter. No personnel were exposed to radiation during this event.
The Nebraska Department of Health and Human Services was notified by a representative of the Omaha Public Power District that a Kay Ray fixed gauge Model Number 7080 source shutter failed to close.  The device contains approximately 25.5 millicuries of Cesium-137.  The gauge is mounted between two fly ash hoppers approximately 20 feet off of the floor. The source closure mechanism on the gauge is connected to a handle located at floor level by a flexible cable.  The closure cable is secured so that when the floor handle is operated, the control cable slides inside of the sheath opening/closing the shutter. The shutter closure cable became loose where the sheath attaches to the source closure mechanism which prevented the shutter from closing. The licensee disconnected the lower part from the cable and the on/off handle. By holding on to the lower part of the sheath and sliding the internal cable, the licensee was able to close the shutter. No personnel were exposed to radiation during this event.

Latest revision as of 20:51, 1 March 2018

ENS 49797 +/-
Where
Omaha Public Power District
Omaha, Nebraska (NRC Region 4)
License number: 01-39-04
Organization: Ne Div Of Radioactive Materials
Reporting
Agreement State
Time - Person (Reporting Time:+0.62 h0.0258 days <br />0.00369 weeks <br />8.49276e-4 months <br />)
Opened: Jim Defrain
17:07 Feb 5, 2014
NRC Officer: Jeff Rotton
Last Updated: Feb 5, 2014
49797 - NRC Website
Loading map...