ENS 49238
ENS Event | |
|---|---|
14:50 Aug 5, 2013 | |
| Title | Agreement State Report - Shutter Stuck on a Process Gauge |
| Event Description | The State of Nebraska submitted the following information via email:
The licensee uses fixed industrial gauges for measuring levels in fly ash hoppers at the station's precipitator building. The industrial fixed gauges contain a Cesium 137 sealed source. The Cesium 137 sources were originally installed in April, 1984, and at the time contained 50 millicuries per source. The sources were manufactured and installed by Kay Ray Inc. The gauge that experienced the event was Kay Ray Gauge, Housing Model #7080 and housing serial number 16784H. The source capsule manufacture was Amersham model no. CDC 800 and K-R Ref. Number serial number 15095 V. In accordance with their license conditions two of the station's chemists were securing the Unit #5's precipitator sources in preparation for an inspection of the precipitator. The 'external' source closure mechanism for Unit #5 precipitator's 5FA-3E & 4E hoppers did not operate as designed and the shutter did not close when the handle on the floor was operated. The radiation sources, which are part of a hopper level sensor, are mounted between two fly ash hoppers 20 feet off the floor. The source closure mechanisms are connected to a handle located at the floor level by a flexible cable. These closure cables are secured to the structures so that when the handles are operated the control cables slide inside a sheath. On the 5FA-3E & 4E source, the shutter closure cable became loose up at the source which allowed the whole cable to slide back and forth when the handle was operated to try and close the shutter. This type of failure has been seen in the past and is easily fixed by tightening the screw which secures the end of the cable to the structure. This required a scaffold to be built up to the source level. A contractor came on site at 12:30 pm [CDT] on 8/5/2013 and erected a scaffold so repairs could be made. |
| Where | |
|---|---|
| Omaha Public Power District Omaha, Nebraska (NRC Region 4) | |
| License number: | 01-39-04 |
| Organization: | Ne Div Of Radioactive Materials |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+1.03 h0.0429 days <br />0.00613 weeks <br />0.00141 months <br />) | |
| Opened: | Randy Lambert 15:52 Aug 5, 2013 |
| NRC Officer: | Pete Snyder |
| Last Updated: | Aug 5, 2013 |
| 49238 - NRC Website
Loading map... | |
Omaha Public Power District with Agreement State | |
WEEKMONTHYEARENS 507802015-01-30T14:20:00030 January 2015 14:20:00
[Table view]Agreement State Agreement State Report - Fixed Gauge Shutter Failed to Close ENS 504932014-09-23T16:50:00023 September 2014 16:50:00 Agreement State Agreement State Report - Failure of a Process Gauge Shutter ENS 497972014-02-05T16:30:0005 February 2014 16:30:00 Agreement State Agreement State Report - Malfunctioning Source Shutter Failed to Close ENS 492382013-08-05T14:50:0005 August 2013 14:50:00 Agreement State Agreement State Report - Shutter Stuck on a Process Gauge ENS 466322011-02-20T14:30:00020 February 2011 14:30:00 Agreement State Agreement State Report - Fly Ash Gauge Shutter Failure ENS 464202010-11-15T17:30:00015 November 2010 17:30:00 Agreement State Agreement State Report - Fly Ash Density Gauge Shutter Fails Open ENS 464042010-11-08T16:15:0008 November 2010 16:15:00 Agreement State Agreement State Report - Process Gauge Shutter Could Not Be Locked Closed ENS 460582010-06-30T16:00:00030 June 2010 16:00:00 Agreement State Agreement State Report - Shutter on Fixed Industrial Gauge Failed to Close ENS 459072010-05-06T18:46:0006 May 2010 18:46:00 Agreement State Agreement State Report - Process Gauge Shutter Malfunction ENS 458012010-03-27T14:50:00027 March 2010 14:50:00 Agreement State Agreement State Report - Fixed Density Gauge Stuck Shutter ENS 457942010-03-25T16:35:00025 March 2010 16:35:00 Agreement State Process Gauge Shutter Malfunction ENS 440012008-01-29T06:00:00029 January 2008 06:00:00 Agreement State Agreement State Report - Missing Tritium Sign 2015-01-30T14:20:00 | |