| Event Description | The following report was received via fax from the State of Nebraska:
The licensee uses fixed industrial gauges for measuring densities in flyash hoppers at the Stations precipitator building. The Industrial gauges contain a Cesium 137 sealed source. The Cesium 137 sources were originally installed in 1984 and at the time contained 50 millicuries per source. The sources were manufactured and installed by Kay Ray Inc. The gauge housing Model No. is 7080. The licensee was performing the semi-annual 'Shutter Function Test' on Unit #4's precipitator sources. The 'external' source closure mechanism for the 4FA-1B & 2B hoppers did not operate as designed and the shutter did not close when the handle on the floor was operated. The external closure cable had detached from the cable clamp on the side of the hopper. In this condition, when the shutter closure mechanism was moved, the cable that operates the source shutter mechanism 20 feet above the floor, bent instead of sliding the cable to the closed position. No personnel were exposed to radiation during this event. This was the fourth similar event at the licensee's plant (March 25, 27, May 6, & June 30, 2010). On June 17, a NE DHHS (Nebraska Department of Health and Human Services), Radioactive Material inspector performed a follow-up investigation on-site. At this plant, OPPD (Omaha Public Power District) has 58 installed operating nuclear fixed gauges. At the time of the investigation, OPPD had replaced 20 of the old shutter cables with a new redesigned direct replacement cable. OPPD plans to replace all of the 58 shutter cables when they fail to operate or as time permits. |
| Where | |
|---|---|
| Omaha Public Power District Omaha, Nebraska (NRC Region 4) | |
| License number: | 01-39-04 |
| Organization: | Ne Div Of Radioactive Materials |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+0.07 h0.00292 days <br />4.166667e-4 weeks <br />9.5886e-5 months <br />) | |
| Opened: | Randy Lambert 16:04 Jun 30, 2010 |
| NRC Officer: | John Knoke |
| Last Updated: | Jun 30, 2010 |
| 46058 - NRC Website
Loading map... | |
Omaha Public Power District with Agreement State | |
WEEKMONTHYEARENS 507802015-01-30T14:20:00030 January 2015 14:20:00
[Table view]Agreement State Agreement State Report - Fixed Gauge Shutter Failed to Close ENS 504932014-09-23T16:50:00023 September 2014 16:50:00 Agreement State Agreement State Report - Failure of a Process Gauge Shutter ENS 497972014-02-05T16:30:0005 February 2014 16:30:00 Agreement State Agreement State Report - Malfunctioning Source Shutter Failed to Close ENS 492382013-08-05T14:50:0005 August 2013 14:50:00 Agreement State Agreement State Report - Shutter Stuck on a Process Gauge ENS 466322011-02-20T14:30:00020 February 2011 14:30:00 Agreement State Agreement State Report - Fly Ash Gauge Shutter Failure ENS 464202010-11-15T17:30:00015 November 2010 17:30:00 Agreement State Agreement State Report - Fly Ash Density Gauge Shutter Fails Open ENS 464042010-11-08T16:15:0008 November 2010 16:15:00 Agreement State Agreement State Report - Process Gauge Shutter Could Not Be Locked Closed ENS 460582010-06-30T16:00:00030 June 2010 16:00:00 Agreement State Agreement State Report - Shutter on Fixed Industrial Gauge Failed to Close ENS 459072010-05-06T18:46:0006 May 2010 18:46:00 Agreement State Agreement State Report - Process Gauge Shutter Malfunction ENS 458012010-03-27T14:50:00027 March 2010 14:50:00 Agreement State Agreement State Report - Fixed Density Gauge Stuck Shutter ENS 457942010-03-25T16:35:00025 March 2010 16:35:00 Agreement State Process Gauge Shutter Malfunction ENS 440012008-01-29T06:00:00029 January 2008 06:00:00 Agreement State Agreement State Report - Missing Tritium Sign 2015-01-30T14:20:00 | |