| title = Part 21 - Non-Conforming Cover Machining | | title = Part 21 - Non-Conforming Cover Machining on Solenoid Valve | ||
| event text = The following is a synopsis of the Part 21 report that was received via fax: | | event text = The following is a synopsis of the Part 21 report that was received via fax: | ||
Cover Machining is installed on upper section of Solenoid Valve and it allows for the electrical connection to the valve solenoid and protects inside wiring of the solenoid from environmental condition. Cover machining part number V52636-567 has 0.190 radius (Drawing V52620-50 Zone D3) which was machined too deep removing material from surface needed for proper O-ring seal. The lack of material exposes part of the sealing O-ring which could diminish the O-ring sealing capability. With O-ring sealing capability diminished, Valcor cannot ensure that valves with Cover Machining Installed on Solenoid Assembly will perform its safety function during all postulated events. | Cover Machining is installed on upper section of Solenoid Valve and it allows for the electrical connection to the valve solenoid and protects inside wiring of the solenoid from environmental condition. Cover machining part number V52636-567 has 0.190 radius (Drawing V52620-50 Zone D3) which was machined too deep removing material from surface needed for proper O-ring seal. The lack of material exposes part of the sealing O-ring which could diminish the O-ring sealing capability. With O-ring sealing capability diminished, Valcor cannot ensure that valves with Cover Machining Installed on Solenoid Assembly will perform its safety function during all postulated events. | ||
Latest revision as of 20:43, 1 March 2018
| Where | |
|---|---|
| Valcor Engineering Corporation, Valcor Springfield, New Jersey (NRC Region 1) | |
| Organization: | Valcor Engineering Corporation |
| Reporting | |
| 10 CFR 21.21(d)(3)(i), Failure to Comply or Defect | |
| Time - Person (Reporting Time:+9.15 h0.381 days <br />0.0545 weeks <br />0.0125 months <br />) | |
| Opened: | Fran Lucano 14:09 Dec 5, 2016 |
| NRC Officer: | Steven Vitto |
| Last Updated: | Dec 5, 2016 |