The following is a synopsis of information received via facsimile:
Valcor Engineering Corporation (VEC) identified a defect with Valcor solenoid valves with part number V52600-5890-1 on October 23, 2023. The defect identified is that stroke matching of internal components was not performed in accordance with internal procedures causing valve flow coefficient (Cv) to be only approximately 50 percent of the minimum required Cv of 2. Substantial safety hazard could be created if the flow rate through the solenoid valve exceeded a certain threshold.
VEC has identified two of these solenoid valves at LaSalle County Nuclear Generating Station (LaSalle) with serial numbers 33 and 34.
For corrective actions, VEC repaired and returned the valve with serial number 34 to LaSalle. To prevent recurrence, VEC intends to improve the training program for production personnel and, if needed, review and revise the stroke matching procedure including enhancing quality assurance oversight of that process. VEC estimates it will take 30 days to complete corrective actions.
Currently, LaSalle is the only known affected facility. Valcor is in the process of identifying and notifying affected customers.