TXX-4890, Interim Deficiency Rept CP-86-13 Re Computer Entry Error Resulting in Potential Invalidation of Jet Impingement Load Review for High Energy Piping.Initially Reported on 860305. Evaluation Continuing.Next Rept by 861021: Difference between revisions
StriderTol (talk | contribs) StriderTol Bot insert |
StriderTol (talk | contribs) StriderTol Bot change |
||
| Line 16: | Line 16: | ||
=Text= | =Text= | ||
{{#Wiki_filter:Log 0 TXX-4890 File # 10110 903.11 TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER . 400 NORTH OLIVE arrREET. I.B. S 8 . DALLAS. TEXAS 75201 July 3, 1986 | {{#Wiki_filter:Log 0 TXX-4890 File # 10110 903.11 TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER. 400 NORTH OLIVE arrREET. I.B. S 8. DALLAS. TEXAS 75201 July 3, 1986 | ||
Mr. Eric H. Johnson, Director | % @ @ @ OD $_ 'N WILLIAM G COUNSIL Enscuviva vics Passesnt Mr. Eric H. Johnson, Director Division of Reactor Safety and Projects U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012 | ||
Division of Reactor Safety and Projects U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012 | |||
==SUBJECT:== | ==SUBJECT:== | ||
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) | COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) | ||
DOCKET NO. 50-445 JET IMPINGEMENT LOAD REVIEW SDAR: | DOCKET NO. 50-445 JET IMPINGEMENT LOAD REVIEW SDAR: | ||
CP-86-13 (INTERIM REPORT) | |||
==Dear Mr. Johnson:== | ==Dear Mr. Johnson:== | ||
On March 5,1986, we verbally notified your Mr. T.F. Westerman of a deficiency involving a computer entry error which could invalidate portions of the jet impingement load review for high energy piping. This is an interim report of a potentially-reportable item under the provisions of 10CFR50.55(e). We have submitted interim reports logged TXX-4753, TXX-4807, and TXX-4833, dated April 4, 1986, May 16, 1986 and June 2, 1986, respectively. | On March 5,1986, we verbally notified your Mr. T.F. Westerman of a deficiency involving a computer entry error which could invalidate portions of the jet impingement load review for high energy piping. This is an interim report of a potentially-reportable item under the provisions of 10CFR50.55(e). We have submitted interim reports logged TXX-4753, TXX-4807, and TXX-4833, dated April 4, 1986, May 16, 1986 and June 2, 1986, respectively. | ||
We are continuing our evaluation and anticipate submitting our next report by October 21, 1986. | We are continuing our evaluation and anticipate submitting our next report by October 21, 1986. | ||
Very truly yours, Y | Very truly yours, Y | ||
ct+1Y W. G. Co i | |||
By: /_,L. | |||
G.S. Keeley Q | G.S. Keeley Q | ||
Manager, Nuclear idcensing JCH/gj c - NRC Region IV (0 + 1 Copy) | Manager, Nuclear idcensing JCH/gj c - NRC Region IV (0 + 1 Copy) | ||
Director, Inspection & Enforcement (15 copies) | Director, Inspection & Enforcement (15 copies) | ||
U. S. Nuclear Regulatory Commission Washington, D.C. 20555 8607110489 860703 PDR S | U. S. Nuclear Regulatory Commission Washington, D.C. | ||
20555 8607110489 860703 PDR ADOCK 05000445 S | |||
p}} | PDR l | ||
p | |||
. - - -}} | |||
Latest revision as of 04:17, 8 December 2024
| ML20202C960 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 07/03/1986 |
| From: | Counsil W, Keeley G TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | Johnson E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| CP-86-13, TXX-4890, NUDOCS 8607110489 | |
| Download: ML20202C960 (1) | |
Text
Log 0 TXX-4890 File # 10110 903.11 TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER. 400 NORTH OLIVE arrREET. I.B. S 8. DALLAS. TEXAS 75201 July 3, 1986
% @ @ @ OD $_ 'N WILLIAM G COUNSIL Enscuviva vics Passesnt Mr. Eric H. Johnson, Director Division of Reactor Safety and Projects U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NO. 50-445 JET IMPINGEMENT LOAD REVIEW SDAR:
CP-86-13 (INTERIM REPORT)
Dear Mr. Johnson:
On March 5,1986, we verbally notified your Mr. T.F. Westerman of a deficiency involving a computer entry error which could invalidate portions of the jet impingement load review for high energy piping. This is an interim report of a potentially-reportable item under the provisions of 10CFR50.55(e). We have submitted interim reports logged TXX-4753, TXX-4807, and TXX-4833, dated April 4, 1986, May 16, 1986 and June 2, 1986, respectively.
We are continuing our evaluation and anticipate submitting our next report by October 21, 1986.
Very truly yours, Y
ct+1Y W. G. Co i
By: /_,L.
G.S. Keeley Q
Manager, Nuclear idcensing JCH/gj c - NRC Region IV (0 + 1 Copy)
Director, Inspection & Enforcement (15 copies)
U. S. Nuclear Regulatory Commission Washington, D.C.
20555 8607110489 860703 PDR ADOCK 05000445 S
PDR l
p
. - - -