TXX-4890, Interim Deficiency Rept CP-86-13 Re Computer Entry Error Resulting in Potential Invalidation of Jet Impingement Load Review for High Energy Piping.Initially Reported on 860305. Evaluation Continuing.Next Rept by 861021

From kanterella
(Redirected from TXX-4890)
Jump to navigation Jump to search
Interim Deficiency Rept CP-86-13 Re Computer Entry Error Resulting in Potential Invalidation of Jet Impingement Load Review for High Energy Piping.Initially Reported on 860305. Evaluation Continuing.Next Rept by 861021
ML20202C960
Person / Time
Site: Comanche Peak 
Issue date: 07/03/1986
From: Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
CP-86-13, TXX-4890, NUDOCS 8607110489
Download: ML20202C960 (1)


Text

Log 0 TXX-4890 File # 10110 903.11 TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER. 400 NORTH OLIVE arrREET. I.B. S 8. DALLAS. TEXAS 75201 July 3, 1986

% @ @ @ OD $_ 'N WILLIAM G COUNSIL Enscuviva vics Passesnt Mr. Eric H. Johnson, Director Division of Reactor Safety and Projects U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76012

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NO. 50-445 JET IMPINGEMENT LOAD REVIEW SDAR:

CP-86-13 (INTERIM REPORT)

Dear Mr. Johnson:

On March 5,1986, we verbally notified your Mr. T.F. Westerman of a deficiency involving a computer entry error which could invalidate portions of the jet impingement load review for high energy piping. This is an interim report of a potentially-reportable item under the provisions of 10CFR50.55(e). We have submitted interim reports logged TXX-4753, TXX-4807, and TXX-4833, dated April 4, 1986, May 16, 1986 and June 2, 1986, respectively.

We are continuing our evaluation and anticipate submitting our next report by October 21, 1986.

Very truly yours, Y

ct+1Y W. G. Co i

By: /_,L.

G.S. Keeley Q

Manager, Nuclear idcensing JCH/gj c - NRC Region IV (0 + 1 Copy)

Director, Inspection & Enforcement (15 copies)

U. S. Nuclear Regulatory Commission Washington, D.C.

20555 8607110489 860703 PDR ADOCK 05000445 S

PDR l

p

. - - -