APPENDIX A NOTICE OF VIOLATION Nebraska Public Power District | APPENDIX A NOTICE OF VIOLATION Nebraska Public Power District Docket: | ||
50-298 Cooper Nuclear Station License: OPR-46 DLeing an NRC inspection conducted October 1-31, 1988, a violation of NRC requiremencs was identified. | |||
The violation involved inadequate access control. | |||
In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, AppenA C (1988), the violation l | |||
1s listed below; Inadequate Access Control l | 1s listed below; Inadequate Access Control l | ||
l Technical Specification 6.3.2.B requires that security jrocedures shall be established and implemented. | l Technical Specification 6.3.2.B requires that security jrocedures shall l | ||
be established and implemented. | |||
Plant Services Procedure 1.1, "Station Security," Revision 9, dated October 3,1988, Section V.D.3.b requires that the Security Department temporarily inactivate an individual's badge when retraining requirements have not been accomplished. | I Plant Services Procedure 1.1, "Station Security," Revision 9, dated October 3,1988, Section V.D.3.b requires that the Security Department temporarily inactivate an individual's badge when retraining requirements have not been accomplished. | ||
Contrary to the above, on October 23 and 24,1988, the licensee did not temporarily inactivate the badge of an individual whuse retraining requirements had not been accomplished, and the individual was allowed unescorted access to protected and vital areas. | Contrary to the above, on October 23 and 24,1988, the licensee did not temporarily inactivate the badge of an individual whuse retraining requirements had not been accomplished, and the individual was allowed unescorted access to protected and vital areas. | ||
This is a Severity Level IV violation. | This is a Severity Level IV violation. | ||
Pursuanc to the provicions of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit to this office, within 30 days of the date of the letter transmitting this Hotice, a written statement or explanation in reply, incirding for each violation: (1) the reason for the violatio- if admitted, (2) the corrective steps which have been taken and the resuito achieved, (3) the corrective steps which will be taken to avoid further violations, and (4) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time. | (Supplement III)(298/8831-01) | ||
Dated at Arlington, Texas | Pursuanc to the provicions of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit to this office, within 30 days of the date of the letter transmitting this Hotice, a written statement or explanation in reply, incirding for each violation: | ||
(1) the reason for the violatio-if admitted, (2) the corrective steps which have been taken and the resuito achieved, (3) the corrective steps which will be taken to avoid further violations, and (4) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time. | |||
Dated at Arlington, Texas | |||
/fg day of fhnt[EA.1988 this gpmn $4h" O | |||
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _}} | |||
Latest revision as of 00:34, 7 December 2024
| ML20206L789 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 11/18/1988 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | |
| Shared Package | |
| ML20206L780 | List: |
| References | |
| 50-298-88-31, NUDOCS 8811300246 | |
| Download: ML20206L789 (1) | |
Text
. _ _ _ _ _ _ _ _ _ _ _ _
APPENDIX A NOTICE OF VIOLATION Nebraska Public Power District Docket:
50-298 Cooper Nuclear Station License: OPR-46 DLeing an NRC inspection conducted October 1-31, 1988, a violation of NRC requiremencs was identified.
The violation involved inadequate access control.
In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, AppenA C (1988), the violation l
1s listed below; Inadequate Access Control l
l Technical Specification 6.3.2.B requires that security jrocedures shall l
be established and implemented.
I Plant Services Procedure 1.1, "Station Security," Revision 9, dated October 3,1988,Section V.D.3.b requires that the Security Department temporarily inactivate an individual's badge when retraining requirements have not been accomplished.
Contrary to the above, on October 23 and 24,1988, the licensee did not temporarily inactivate the badge of an individual whuse retraining requirements had not been accomplished, and the individual was allowed unescorted access to protected and vital areas.
This is a Severity Level IV violation.
(Supplement III)(298/8831-01)
Pursuanc to the provicions of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit to this office, within 30 days of the date of the letter transmitting this Hotice, a written statement or explanation in reply, incirding for each violation:
(1) the reason for the violatio-if admitted, (2) the corrective steps which have been taken and the resuito achieved, (3) the corrective steps which will be taken to avoid further violations, and (4) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time.
Dated at Arlington, Texas
/fg day of fhnt[EA.1988 this gpmn $4h" O
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _