{{#Wiki_filter:1 Northern States Power Company 414 Nacollet Malt Minneapolis. Minnesota 5540t Te% phone 1612) 330-5500 June 3,  1985 Director Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 Prairie Island Nuclear Generating Plant Docket Nos. 50-282 License Nos. DPR-42 50-306                  DPR-60 Supplement No. I to License Amendment Request Dated May 17, 1985 In our License Amendment Request dated May 17, 1985 we submitted proposed Technical Specification changes which would allow the use of steam generator tube sleeving repairs. The purpose of this letter is to supplement our May 17, 1985 request with proprietary versions of the two Westinghouse topical reports included as Appendices C and D of that submittal.
Enclosed are:
: 1. Eight copies of WCAP 10756, " Prairie Island Units 1 and 2 Steam Generator Sleeving (Mechanical Sleeves)", Westing-house Proprietary Class 2, January, 1985.
: 2. Eight copies of WCAP 10815, " Prairie Island Units 1 and 2 Steam Generator Sleeving (Brazed Sleeves)", Westinghouse Proprietary Class 2, January, 1985.
Aleo enclosed are Westinghouse authorization letters CAW-85-022 and CAW-85-027 and accompanying affidavits.
These reports contain information proprietary to Westinghouse Electric Corporation as .upported by the affidavit signed by Westinghouse, the owner of the information.        The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.
kok0lfjg83850603 P          K 05000282 PDR CONTAINS PROPRIETARY INFORMATION TO BE WITHHELD FROM PUBLIC DISCLOSURE IN ACCORDANCE WITH 10 CFR SECTION 2.790 i to cf1 d)Cr1 P. ID S15 f jfo(          y cys alm f ie'ir4 P l0 efS CM-294 f
 
                                                                                )
  .-                                                                              l 1
I Northem States Power Company Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 3ection 2.790. Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse affidavit should refer-ence the applicable Westinghouse authorization letter and be ad-dressed to R A Wiesemann, Manager, Regulatory & Legislative Af-fairs, Westinghouse Electric Corporation, PO Box 355, Pittsburgh, Pennsylvania 15230.
D$ ku, David Musolf Manager - Nuclear S  port Services Attachments c: Regional Administrator III, NRC (w/o attachments)
Resident Inspector, NRC          (w/o attachments)
G Charnoff                      (w/o attachments)
CONTAINS PROPRIETARY INFORMATION TO BE WITHHELD FROM PUBLIC DISCLOSURE IN ACCORANCE WITH 10 CFR SECTION 2.790 I' -.}}

Revision as of 02:03, 24 July 2020

Suppl 1 to Application for Amends to Licenses DPR-42 & DPR-60,revising Tech Specs to Authorize Use of Steam Generator Sleeves for Repair of Defective Steam Generator Tubes.Proprietary Repts Withheld (Ref 10CFR2.790)
ML20126A251
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 06/03/1985
From: Musolf D
NORTHERN STATES POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19344C015 List:
References
TAC-57847, TAC-57848, NUDOCS 8506130283
Download: ML20126A251 (2)


Text

1 Northern States Power Company 414 Nacollet Malt Minneapolis. Minnesota 5540t Te% phone 1612) 330-5500 June 3, 1985 Director Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 Prairie Island Nuclear Generating Plant Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Supplement No. I to License Amendment Request Dated May 17, 1985 In our License Amendment Request dated May 17, 1985 we submitted proposed Technical Specification changes which would allow the use of steam generator tube sleeving repairs. The purpose of this letter is to supplement our May 17, 1985 request with proprietary versions of the two Westinghouse topical reports included as Appendices C and D of that submittal.

Enclosed are:

1. Eight copies of WCAP 10756, " Prairie Island Units 1 and 2 Steam Generator Sleeving (Mechanical Sleeves)", Westing-house Proprietary Class 2, January, 1985.
2. Eight copies of WCAP 10815, " Prairie Island Units 1 and 2 Steam Generator Sleeving (Brazed Sleeves)", Westinghouse Proprietary Class 2, January, 1985.

Aleo enclosed are Westinghouse authorization letters CAW-85-022 and CAW-85-027 and accompanying affidavits.

These reports contain information proprietary to Westinghouse Electric Corporation as .upported by the affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

kok0lfjg83850603 P K 05000282 PDR CONTAINS PROPRIETARY INFORMATION TO BE WITHHELD FROM PUBLIC DISCLOSURE IN ACCORDANCE WITH 10 CFR SECTION 2.790 i to cf1 d)Cr1 P. ID S15 f jfo( y cys alm f ie'ir4 P l0 efS CM-294 f

)

.- l 1

I Northem States Power Company Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 3ection 2.790. Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse affidavit should refer-ence the applicable Westinghouse authorization letter and be ad-dressed to R A Wiesemann, Manager, Regulatory & Legislative Af-fairs, Westinghouse Electric Corporation, PO Box 355, Pittsburgh, Pennsylvania 15230.

D$ ku, David Musolf Manager - Nuclear S port Services Attachments c: Regional Administrator III, NRC (w/o attachments)

Resident Inspector, NRC (w/o attachments)

G Charnoff (w/o attachments)

CONTAINS PROPRIETARY INFORMATION TO BE WITHHELD FROM PUBLIC DISCLOSURE IN ACCORANCE WITH 10 CFR SECTION 2.790 I' -.