ML19209C418: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19209C421 | | number = ML19209C421 | ||
| issue date = 10/11/1979 | | issue date = 10/11/1979 | ||
| title = | | title = LER 79-081/03L-0:on 790926,both Doors to Reactor Bldg Breezeway Airlock Could Be Opened Simultaneously.Caused by Loose Door Position Solenoids Preventing Interlock Feature from Working.Lock Washers Installed to Ensure Tightness | ||
| author name = Tollison A | | author name = Tollison A | ||
| author affiliation = CAROLINA POWER & LIGHT CO. | | author affiliation = CAROLINA POWER & LIGHT CO. |
Latest revision as of 06:17, 24 January 2020
Date released: 08/11/2019 | Download: ML19209C418 |
---|---|
ML19209C421 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 10/11/1979 |
From: | Tollison A CAROLINA POWER & LIGHT CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19209C421 (1) | |
ML19209C417 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 10/11/1979 |
From: | Banks H CAROLINA POWER & LIGHT CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19209C417 (1) | |