| title = | | title = LER 80-003/01T-0:on 800116,during Inservice Insp on Core Spray Sparger Piping for Sys Ii,Two Indications of Cracks Discovered.Ultrasonic Test Revealed through-wall Cracks. Possibly Caused by Sparger Installation Method | ||
| author name = Ross D | | author name = Ross D | ||
| author affiliation = JERSEY CENTRAL POWER & LIGHT CO. | | author affiliation = JERSEY CENTRAL POWER & LIGHT CO. | ||
Latest revision as of 14:45, 23 January 2020
| Date released: 09/28/2019 | Download: ML19257D694 |
|---|---|
| ML19257D701 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 01/30/1980 |
| From: | Ross D JERSEY CENTRAL POWER & LIGHT CO. |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| Download: ML19257D701 (3) | |
| ML19257D693 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 01/30/1980 |
| From: | Finfrock I JERSEY CENTRAL POWER & LIGHT CO. |
| To: | GRIER B H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |