ML19257D694: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
 
Created page by program invented by StriderTol
 
Line 6: Line 6:
| number = ML19257D701
| number = ML19257D701
| issue date = 01/30/1980
| issue date = 01/30/1980
| title = Forwards LER 80-003/01T-0
| title = LER 80-003/01T-0:on 800116,during Inservice Insp on Core Spray Sparger Piping for Sys Ii,Two Indications of Cracks Discovered.Ultrasonic Test Revealed through-wall Cracks. Possibly Caused by Sparger Installation Method
| author name = Ross D
| author name = Ross D
| author affiliation = JERSEY CENTRAL POWER & LIGHT CO.
| author affiliation = JERSEY CENTRAL POWER & LIGHT CO.

Latest revision as of 14:45, 23 January 2020

Forwards LER 80-003/01T-0
Date released: 09/28/2019 Download: ML19257D694


LER 80-003/01T-0:on 800116,during Inservice Insp on Core Spray Sparger Piping for Sys Ii,Two Indications of Cracks Discovered.Ultrasonic Test Revealed through-wall Cracks. Possibly Caused by Sparger Installation Method
ML19257D701
Person / Time
Site: Oyster Creek
Issue date: 01/30/1980
From: Ross D
JERSEY CENTRAL POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19257D701 (3)
Forwards LER 80-003/01T-0
ML19257D693
Person / Time
Site: Oyster Creek
Issue date: 01/30/1980
From: Finfrock I
JERSEY CENTRAL POWER & LIGHT CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19257D693 (1)