ML19257D856: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 6: Line 6:
| number = ML19257D864
| number = ML19257D864
| issue date = 01/29/1980
| issue date = 01/29/1980
| title = Forwards LER 80-003/03L-0
| title = LER 80-003/03L-0:on 800103,during Reactor Startup,Vessel Conductivity Exceeded 2 Umho for 31-h.Caused by Auxiliary Boilers Being Isolated for Months & Supply Lines Containing Stagnant,High Conductivity Water
| author name = Tollison A
| author name = Tollison A
| author affiliation = CAROLINA POWER & LIGHT CO.
| author affiliation = CAROLINA POWER & LIGHT CO.

Latest revision as of 15:39, 23 January 2020

Forwards LER 80-003/03L-0
Date released: 09/28/2019 Download: ML19257D856


LER 80-003/03L-0:on 800103,during Reactor Startup,Vessel Conductivity Exceeded 2 Umho for 31-h.Caused by Auxiliary Boilers Being Isolated for Months & Supply Lines Containing Stagnant,High Conductivity Water
ML19257D864
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 01/29/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19257D864 (2)
Forwards LER 80-003/03L-0
ML19257D855
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 01/29/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19257D855 (1)