| title = | | title = LER 79-030/01T-0:on 791002,rigid Hanger Failed Due to Contact Between Two of Four Bolts & Base Plate.Caused by Improper Installation.Two shell-type Bolts Were Replaced W/ wedge-type Bolts & Plate Washers Were Installed | ||
| author name = Cooney M | | author name = Cooney M | ||
| author affiliation = PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC | | author affiliation = PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
Latest revision as of 13:54, 23 January 2020
Date released: 09/30/2019 | Download: ML19259D684 |
---|---|
ML19259D691 | |
Person / Time | |
---|---|
Site: | Peach Bottom ![]() |
Issue date: | 10/17/1979 |
From: | Cooney M PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
References | |
Download: ML19259D691 (1) | |
ML19259D683 | |
Person / Time | |
---|---|
Site: | Peach Bottom ![]() |
Issue date: | 10/17/1979 |
From: | Cooney M PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
To: | GRIER B H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |