ML19274D444: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 6: Line 6:
| number = ML19274D447
| number = ML19274D447
| issue date = 01/15/1979
| issue date = 01/15/1979
| title = Forwards LER 78-071/03L-0
| title = LER 78-071/03L-0 on 781224:failure of Sample Pump for Radiation Monitor RMA-6.Caused by Worn & Distorted Carbon Vanes in Pump
| author name = Cooper J
| author name = Cooper J
| author affiliation = FLORIDA POWER CORP.
| author affiliation = FLORIDA POWER CORP.

Latest revision as of 08:00, 23 January 2020

Forwards LER 78-071/03L-0
Date released: 10/15/2019 Download: ML19274D444


LER 78-071/03L-0 on 781224:failure of Sample Pump for Radiation Monitor RMA-6.Caused by Worn & Distorted Carbon Vanes in Pump
ML19274D447
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 01/15/1979
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19274D447 (2)
Forwards LER 78-071/03L-0
ML19274D443
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 01/19/1979
From: Stewart W
FLORIDA POWER CORP.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19274D443 (1)