{{#Wiki_filter:Page 1 of 1 PUBLIC SUBMISSION Docket: NRC-2016-0224 Restart of a Nuclear Power Plant Shut Down by a Seismic Event Comment On: NRC-2016-0224-0003 As of: 3/3/17 11:41 AM Received:
{{#Wiki_filter:Page 1 of 1 As of: 3/3/17 11:41 AM Received: February 28, 2017 Status: Pending_Post PUBLIC SUBMISSION                                                        Tracking No. lkl-8uzq-4ars Comments Due: February 28, 2017 Submission Type: Web Docket: NRC-2016-0224 Restart of a Nuclear Power Plant Shut Down by a Seismic Event                                      11P/~1~
February 28, 2017 Status: Pending_Post Tracking No. lkl-8uzq-4ars Comments Due: February 28, 2017 Submission Type: Web Guidance:
Comment On: NRC-2016-0224-0003                                                        ~;r;:_/'(,? ~::;
Restart of a Nuclear Power Plant Shut Down by a Seismic Event eJ Document:
Guidance: Restart of a Nuclear Power Plant Shut Down by a Seismic Event Document: NRC-2016-0224-DRAFT-0005 Comment on FR Doc# 2016-30895
NRC-2016-0224-DRAFT-0005 Comment on FR Doc# 2016-30895 Submitter Information Name: T. Stewart --.-, _) .. _) .-*n _ . ., "* ) t .. , i **----._,, -i-1 --, '.f ...... ' '.../ .... :-.J ! w : --=r.-;: -'---* ::C1 r--r" rr Cf; ', .. -*-* .. -..., '-, :--i General Comment :. ) --::*-,_.,..., w (0 (_;') Virgil C. Summer Nuclear Station (VCSNS) Unit 1 revised its station procedures concerning earthquake and incorporated guidance provided in Regulatory Guide (RG) 1.167 Revision 0 and EPRI NP-6695, "Guidance for Nuclear Power Plan Response to an Earthquake," in addressing INPO IER L2 12-12, "Greater than Basis Earthquake Results in a Loss of Off Site Power and Reactor SCRAM" and INPO IER L4 13-3, "Recovering froma Beyond-Design-Basis Natural Event -Lessons Learned." VCSNS J]nit 1 requests that the NRC does not approve any imposition or backfitting of the guidance provided in RG 1.167 Revision 1 for existing licensees who have incorporated previous guidance into their earthquake response. ) SUNSI Review Complete Template = ADM -013 E-RIDS= ADM-03 Add=
                                                                                              --.-,
https://www.fdms.gov/fdms/getcontent?objectld=09000064824dfc4b&format=xml&showorig=false 03/03/2017 . I}}
_).. _)
eJ  '.f      ~                ::C1 Submitter Information                            .-*n
_..,
                                                                                                                ......
                                                                                                              ....
                                                                                                                        '
                                                                                                                      '.../
r--
r" rr Cf;
                                                                                                    )"*      :-.J
                                                                                                      ..,        !
Name: T. Stewart                                                                            t i          w                     ',    ..
                                                                                                                                          -*-*..
                                                                                              **---
                                                                                              -._,,
                                                                                            -i-1
                                                                                                              --
                                                                                                            =r.-;:
:
                                                                                                                                -'-  ~
                                                                                                                                        -...,
                                                                                                            --*
                                                                                                                                    ~-
                                                                                                                                    '-   ,
                                                                                            --,                                   :--i General Comment                             :.,_.,...,)
w (0
                                                                                                                                    --::*-
r*r~1
(_;')
Virgil C. Summer Nuclear Station (VCSNS) Unit 1 revised its station procedures concerning earthquake
    ~esponse and incorporated guidance provided in Regulatory Guide (RG) 1.167 Revision 0 and EPRI NP-6695, "Guidance for Nuclear Power Plan Response to an Earthquake," in addressing INPO IER L2 12-12, "Greater than D~sign Basis Earthquake Results in a Loss of Off Site Power and Reactor SCRAM" and INPO IER L4 13-3, "Recovering froma Beyond-Design-Basis Natural Event - Lessons Learned." VCSNS J]nit 1 requests that the NRC does not approve any imposition or backfitting of the guidance provided in RG 1.167 Revision 1 for existing licensees who have incorporated previous guidance into their earthquake response.
                        )
SUNSI Review Complete Template = ADM - 013 E-RIDS= ADM-03 Add=   ;D-f)~(:.;Xo) https://www.fdms.gov/fdms/getcontent?objectld=09000064824dfc4b&format=xml&showorig=false                                     03/03/2017
      . I}}

Revision as of 06:59, 30 October 2019

Comment (5) of T. Stewart on Behalf of Virgil C. Summer Nuclear Station Unit 1 on Restart of a Nuclear Power Plant Shut Down by a Seismic Event
ML17067A114
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 02/28/2017
From: Stewart T
South Carolina Electric & Gas Co
To:
Rules, Announcements, and Directives Branch
References
81FR76633 00005, NRC-2016-0224
Download: ML17067A114 (1)


Text

Page 1 of 1 As of: 3/3/17 11:41 AM Received: February 28, 2017 Status: Pending_Post PUBLIC SUBMISSION Tracking No. lkl-8uzq-4ars Comments Due: February 28, 2017 Submission Type: Web Docket: NRC-2016-0224 Restart of a Nuclear Power Plant Shut Down by a Seismic Event 11P/~1~

Comment On: NRC-2016-0224-0003 ~;r;:_/'(,? ~::;

Guidance: Restart of a Nuclear Power Plant Shut Down by a Seismic Event Document: NRC-2016-0224-DRAFT-0005 Comment on FR Doc# 2016-30895

--.-,

_).. _)

eJ '.f ~  ::C1 Submitter Information .-*n

_..,

......

....

'

'.../

r--

r" rr Cf;

)"*  :-.J

..,  !

Name: T. Stewart t i w ', ..

-*-*..

    • ---

-._,,

-i-1

--

=r.-;:

-'- ~

-...,

--*

~-

'- ,

--,  :--i General Comment  :.,_.,...,)

w (0

--::*-

r*r~1

(_;')

Virgil C. Summer Nuclear Station (VCSNS) Unit 1 revised its station procedures concerning earthquake

~esponse and incorporated guidance provided in Regulatory Guide (RG) 1.167 Revision 0 and EPRI NP-6695, "Guidance for Nuclear Power Plan Response to an Earthquake," in addressing INPO IER L2 12-12, "Greater than D~sign Basis Earthquake Results in a Loss of Off Site Power and Reactor SCRAM" and INPO IER L4 13-3, "Recovering froma Beyond-Design-Basis Natural Event - Lessons Learned." VCSNS J]nit 1 requests that the NRC does not approve any imposition or backfitting of the guidance provided in RG 1.167 Revision 1 for existing licensees who have incorporated previous guidance into their earthquake response.

)

SUNSI Review Complete Template = ADM - 013 E-RIDS= ADM-03 Add= ;D-f)~(:.;Xo) https://www.fdms.gov/fdms/getcontent?objectld=09000064824dfc4b&format=xml&showorig=false 03/03/2017