{{#Wiki_filter:Code of Federal Regulations
{{#Wiki_filter:SOUTHERN NUCLEAR OPERATING COMPANY, INC.
GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MEAG POWER SPVM, LLC MEAG POWER SPVJ, LLC MEAG POWER SPVP, LLC CITY OF DALTON, GEORGIA VOGTLE ELECTRIC GENERATING PLANT UNIT 3 DOCKET NO. 52-025 EXEMPTION FROM REGULATIONS SET FORTH IN APPENDIX D OF 10 CFR PART 52 Exemption License No. NPF-91
: 1. In a letter dated November 16, 2018, as supplemented by letter dated January 24, 2019, the Southern Nuclear Operating Company (SNC) requested from the Nuclear Regulatory Commission (NRC or Commission) an exemption to allow departures from Tier 1 information in the certified Design Control Document (DCD) incorporated by reference in Title 10 of the Code of Federal Regulations (10 CFR) Part 52, Appendix D, Design Certification Rule for the AP1000 Design, as part of license amendment request (LAR) 18-028, Routing of Class 1E Divisional Cables Supporting Passive Containment Cooling.
For the reasons set forth in Section 3.2 of the NRC staffs Safety Evaluation, which can be found at Agencywide Documents Access and Management System (ADAMS)
Accession Number ML19113A261, the Commission finds that:
A.      the exemption is authorized by law; B.      the exemption presents no undue risk to public health and safety; C.      the exemption is consistent with the common defense and security; D.      special circumstances are present in that the application of the rule in this circumstance is not necessary to serve the underlying purpose of the rule; E.      the special circumstances outweigh any decrease in safety that may result from the reduction in standardization caused by the exemption; and


    /RA/}}
F. the exemption will not result in a significant decrease in the level of safety otherwise provided by the design.
: 2. Accordingly, the SNC is granted an exemption from the certified DCD Tier 1 information, with corresponding changes to Appendix C of the Facility Combined License, as described in the licensees request dated November 16, 2018, as supplemented by letter dated January 24, 2019. This exemption is related to, and necessary for, the granting of License Amendment No. 161, which is being issued concurrently with this exemption.
: 3. As explained in Section 5.0 of the NRC staffs Safety Evaluation (ADAMS Accession Number ML19113A261), this exemption meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment needs to be prepared in connection with the issuance of the exemption.
: 4. This exemption is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION:
                                    /RA/
Anna H. Bradford, Deputy Director Division of Licensing, Siting, and Environmental Analysis Office of New Reactors Date of Issuance: May 20, 2019}}

Latest revision as of 21:12, 19 October 2019

Exemption - Vogtle Electric Generating Plant, Unit 3 (LAR 18-028)
ML19113A259
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 05/20/2019
From: Anna Bradford, Jennifer Dixon-Herrity, Peter Hearn
NRC/NRO/DLSE/LB2
To:
Georgia Power Co, MEAG Power, Oglethorpe Power Corp, Southern Nuclear Operating Co
HEARN P/NRO
Shared Package
ML19113A253 List:
References
EPID LL-2018--LLA-0300, LAR 18-028
Download: ML19113A259 (2)


Text

SOUTHERN NUCLEAR OPERATING COMPANY, INC.

GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MEAG POWER SPVM, LLC MEAG POWER SPVJ, LLC MEAG POWER SPVP, LLC CITY OF DALTON, GEORGIA VOGTLE ELECTRIC GENERATING PLANT UNIT 3 DOCKET NO.52-025 EXEMPTION FROM REGULATIONS SET FORTH IN APPENDIX D OF 10 CFR PART 52 Exemption License No. NPF-91

1. In a letter dated November 16, 2018, as supplemented by letter dated January 24, 2019, the Southern Nuclear Operating Company (SNC) requested from the Nuclear Regulatory Commission (NRC or Commission) an exemption to allow departures from Tier 1 information in the certified Design Control Document (DCD) incorporated by reference in Title 10 of the Code of Federal Regulations (10 CFR) Part 52, Appendix D, Design Certification Rule for the AP1000 Design, as part of license amendment request (LAR)18-028, Routing of Class 1E Divisional Cables Supporting Passive Containment Cooling.

For the reasons set forth in Section 3.2 of the NRC staffs Safety Evaluation, which can be found at Agencywide Documents Access and Management System (ADAMS)

Accession Number ML19113A261, the Commission finds that:

A. the exemption is authorized by law; B. the exemption presents no undue risk to public health and safety; C. the exemption is consistent with the common defense and security; D. special circumstances are present in that the application of the rule in this circumstance is not necessary to serve the underlying purpose of the rule; E. the special circumstances outweigh any decrease in safety that may result from the reduction in standardization caused by the exemption; and

F. the exemption will not result in a significant decrease in the level of safety otherwise provided by the design.

2. Accordingly, the SNC is granted an exemption from the certified DCD Tier 1 information, with corresponding changes to Appendix C of the Facility Combined License, as described in the licensees request dated November 16, 2018, as supplemented by letter dated January 24, 2019. This exemption is related to, and necessary for, the granting of License Amendment No. 161, which is being issued concurrently with this exemption.
3. As explained in Section 5.0 of the NRC staffs Safety Evaluation (ADAMS Accession Number ML19113A261), this exemption meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment needs to be prepared in connection with the issuance of the exemption.
4. This exemption is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION:

/RA/

Anna H. Bradford, Deputy Director Division of Licensing, Siting, and Environmental Analysis Office of New Reactors Date of Issuance: May 20, 2019