ML18038A898: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) Created page by program invented by StriderTol |
StriderTol (talk | contribs) Created page by program invented by StriderTol |
||
| Line 22: | Line 22: | ||
| issue date = 09/07/1994 | | issue date = 09/07/1994 | ||
| title = Part 21 Rept Re Defect in Latching Mechanism of Potter & Brumfield Relay on C&D High Voltage Shut Down Alarm Assembly Printed Circuit Boards.Pull Test on Relay Reset Button Incorporated Into Receiving Insp Procedures | | title = Part 21 Rept Re Defect in Latching Mechanism of Potter & Brumfield Relay on C&D High Voltage Shut Down Alarm Assembly Printed Circuit Boards.Pull Test on Relay Reset Button Incorporated Into Receiving Insp Procedures | ||
| author name = | | author name = Kinden T | ||
| author affiliation = C&D CHARTER POWER SYSTEMS, INC. (FORMERLY C&D POWER | | author affiliation = C&D CHARTER POWER SYSTEMS, INC. (FORMERLY C&D POWER | ||
| addressee name = | | addressee name = | ||
Revision as of 09:49, 25 June 2019
| Date released: 09/27/2018 | Download: ML18038A898 |
|---|---|
| ML18039A937 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 06/06/1994 |
| From: | NUCLEAR LOGISTICS, INC. (NLI) |
| To: | |
| References | |
| Download: ML18039A937 (14) | |
| ML18038A897 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 09/07/1994 |
| From: | Kinden T C&D CHARTER POWER SYSTEMS, INC. (FORMERLY C&D POWER |
| To: | NRC |
| References | |
| REF-PT21-94 | |
| Download: ML18038A897 (10) | |