ENS 41623: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 04/21/2005 20:13 EST | | event date = 04/21/2005 20:13 EST | ||
| last update date = 04/22/2005 | | last update date = 04/22/2005 | ||
| title = Autoclave Shutdown Due | | title = Autoclave Shutdown Due to High Condensate | ||
| event text = On 04/21/05 at 2013 hours, Autoclave #2 in the X-343 Facility experienced a Steam Shutdown due to high condensate level alarms (A) and (B) actuating. The autoclave was in an applicable TSR mode (Mode II, Heating) at the time of the alarm actuations. The autoclave was placed in Mode VII (Shutdown) and declared INOPERABLE by the Plant Shift Superintendent (PSS). An investigation is underway to determine the cause of the actuations. No release of radioactive material occurred as a result of this incident. This event is being reported in accordance with UE2-RA RE1030, Appendix D. J. 2. Safety System Actuations. NRC, Region II has been notified of this event. | | event text = On 04/21/05 at 2013 hours, Autoclave #2 in the X-343 Facility experienced a Steam Shutdown due to high condensate level alarms (A) and (B) actuating. The autoclave was in an applicable TSR mode (Mode II, Heating) at the time of the alarm actuations. The autoclave was placed in Mode VII (Shutdown) and declared INOPERABLE by the Plant Shift Superintendent (PSS). An investigation is underway to determine the cause of the actuations. No release of radioactive material occurred as a result of this incident. This event is being reported in accordance with UE2-RA RE1030, Appendix D. J. 2. Safety System Actuations. NRC, Region II has been notified of this event. | ||
| URL = http://www.nrc.gov/reading-rm/doc-collections/event-status/event/2005/20050425en.html#en41623 | | URL = http://www.nrc.gov/reading-rm/doc-collections/event-status/event/2005/20050425en.html#en41623 |
Revision as of 22:21, 1 March 2018
Where | |
---|---|
Portsmouth Gaseous Diffusion Plant Piketon, Ohio (NRC Region 2) | |
License number: | Gdp-2 |
Reporting | |
Other Unspec Reqmnt | |
Time - Person (Reporting Time:+9.7 h0.404 days <br />0.0577 weeks <br />0.0133 months <br />) | |
Opened: | Eric Spaeth 10:55 Apr 22, 2005 |
NRC Officer: | Pete Snyder |
Last Updated: | Apr 22, 2005 |
41623 - NRC Website
| |