ENS 45188
ENS Event | |
|---|---|
04:54 Jul 7, 2009 | |
| Title | 4-Hour Report Due to Notification of Ohio Epa Because of Boiler Opacity Limit Being Exceeded |
| Event Description | At 2130 hours0.0247 days <br />0.592 hours <br />0.00352 weeks <br />8.10465e-4 months <br />, 07/06/09, the PORTS Plant Shift Superintendent's (PSS) Office was notified of an operational upset at the X-600 Steam Plant Facility due to a loss of power on the #3 (operating) Boiler. The operational upset resulted in three separate six minute periods, where the permissible opacity limit was exceeded, while power was being restored to the boiler. The PORTS PSS Office notified the Ohio Environmental Protection Agency (OEPA) of this incident, at 0054 hours6.25e-4 days <br />0.015 hours <br />8.928571e-5 weeks <br />2.0547e-5 months <br />, 07/07/09. This notification to another government agency is reportable to the NRC as a 4-hour Event, per the United States Enrichment Corporation (USEC) Nuclear Regulatory Event Reporting Procedure UE2-RA-RE1030, Appendix D, Section P (Miscellaneous) which states: 'USEC shall notify NRC of any event or situation, related to the health and safety of the public or on-site personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made. Such an event may include an on-site fatality or inadvertent release of radioactively contaminated materials'.
The licensee notified the Paducah NRC Resident Inspector.
PORTS [Nuclear Regulatory Affairs] NRA has reviewed the basis for the above NRC event notification and recommends that event notification#45188 be retracted. The following provides the basis for this recommendation. NUREG-1022, Event Reporting Guidelines 10 CFR 50.72 and 50.73 was reviewed. In essence, the following sentence from the NUREG provides sufficient clarification of the reporting criteria to assess the applicability of the steam plant opacity exceedances: 'The purpose of this criterion is to ensure the NRC is made aware of issues that will cause heightened public or government concern related to the radiological health and safety of the public or on-site personnel or protection of the environment.' The significance of opacity exceedances as they might impact the public or on-site workers was discussed with environmental compliance personnel. It was concluded that beyond any regulatory issues, opacity exceedances of limited duration pose no significant health or environmental concerns. Based on the specifics of this event and the additional guidance provided by the NRC, more specifically that NRC is most concerned about events or situations that would cause heightened public or government concern, the opacity exceedances reported to the OEPA should not trigger a 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> NRC report. The licensee notified the NRC Resident Inspector. Notified R2DO(Nease) and NMSS EO(Tschiltz) |
| Where | |
|---|---|
| Portsmouth Piketon, Ohio (NRC Region 2) | |
| License number: | GDP-2 |
| Reporting | |
| Other Unspec Reqmnt | |
| Time - Person (Reporting Time:+-2.95 h-0.123 days <br />-0.0176 weeks <br />-0.00404 months <br />) | |
| Opened: | Ron Crabtree 01:57 Jul 7, 2009 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Jul 9, 2009 |
| 45188 - NRC Website
Loading map... | |
Portsmouth Gaseous Diffusion Plant with Other Unspec Reqmnt | |
WEEKMONTHYEARENS 459252010-05-13T20:02:00013 May 2010 20:02:00
[Table view]Other Unspec Reqmnt Notification of Ohio Environmental Protection Agency Due to Exceeding Npdes Discharge Permit Value ENS 459172010-05-11T21:09:00011 May 2010 21:09:00 Other Unspec Reqmnt Offsite Notification ENS 457522010-03-08T05:00:0008 March 2010 05:00:00 Other Unspec Reqmnt Potential Release of Contaminated Materals Off-Site ENS 451882009-07-07T04:54:0007 July 2009 04:54:00 Other Unspec Reqmnt 4-Hour Report Due to Notification of Ohio Epa Because of Boiler Opacity Limit Being Exceeded ENS 437832007-11-14T13:30:00014 November 2007 13:30:00 Other Unspec Reqmnt 24-Hr Incident Report - Safety System Actuation ENS 436712007-09-28T15:16:00028 September 2007 15:16:00 Other Unspec Reqmnt Smoke from Steam Plant Startup Requiring State Notification ENS 435782007-08-18T06:10:00018 August 2007 06:10:00 Other Unspec Reqmnt Feed Facility Autoclave O-Ring Failure ENS 435492007-08-04T14:25:0004 August 2007 14:25:00 Other Unspec Reqmnt X-342 Facility Containment Shutdown ENS 421702005-11-26T02:20:00026 November 2005 02:20:00 Other Unspec Reqmnt Oil Spill on Plant Site ENS 416232005-04-22T01:13:00022 April 2005 01:13:00 Other Unspec Reqmnt Autoclave Shutdown Due to High Condensate ENS 413912005-02-09T17:03:0009 February 2005 17:03:00 Other Unspec Reqmnt Offsite Notification Due to Reportable Quantity Spill Contained on Site ENS 406762004-04-15T14:30:00015 April 2004 14:30:00 Other Unspec Reqmnt Hazardous Material Spill ENS 405992004-03-19T14:10:00019 March 2004 14:10:00 Other Unspec Reqmnt Safety System Actuation at Portsmouth Gdp ENS 401242003-09-02T01:45:0002 September 2003 01:45:00 Other Unspec Reqmnt Manual Actuation of Safety Equipment for Autoclave Containment 2010-05-13T20:02:00 | |