Line 16: Line 16:
| event date = 03/04/2015 CDT
| event date = 03/04/2015 CDT
| last update date = 03/24/2015
| last update date = 03/24/2015
| title = Agreement State Report - Ohmart Shlm-Cr3 Cable Detached From Source
| title = Agreement State Report - Ohmart Shlm-Cr3 Cable Detached from Source
| event text = The following report from the Texas Department of State Health Services was provided via email:
| event text = The following report from the Texas Department of State Health Services was provided via email:
On March 19, 2015, the licensee notified the Agency [Texas Department of State Health Services] that on March 4, 2015, while preparing for a shutdown for maintenance, it retracted a cesium-137 source back into its Ohmart SHLM-CR3 source holder when the cable came off of the source. The gauge contains a 2,400 milliCurie (original activity 04/1991) cesium-137 source.  The licensee performed a survey to confirm the source was in the fully shielded position and placed a lock on the shutter.  No individual received any exposure as a result of this event.  The licensee is coordinating with the manufacturer to have the gauge repaired.  An investigation into this event is ongoing.  More information will be provided as it is obtained in accordance with SA-300.
On March 19, 2015, the licensee notified the Agency [Texas Department of State Health Services] that on March 4, 2015, while preparing for a shutdown for maintenance, it retracted a cesium-137 source back into its Ohmart SHLM-CR3 source holder when the cable came off of the source. The gauge contains a 2,400 milliCurie (original activity 04/1991) cesium-137 source.  The licensee performed a survey to confirm the source was in the fully shielded position and placed a lock on the shutter.  No individual received any exposure as a result of this event.  The licensee is coordinating with the manufacturer to have the gauge repaired.  An investigation into this event is ongoing.  More information will be provided as it is obtained in accordance with SA-300.

Latest revision as of 20:48, 1 March 2018

ENS 50905 +/-
Where
Union Carbide Corporation
Port Lavaca, Texas (NRC Region 4)
License number: 00051
Organization: Texas Dept Of State Health Services
Reporting
Agreement State
Time - Person (Reporting Time:+370.75 h15.448 days <br />2.207 weeks <br />0.508 months <br />)
Opened: Karen Blanchard
14:45 Mar 19, 2015
NRC Officer: Jeff Herrera
Last Updated: Mar 24, 2015
50905 - NRC Website