Title | Agreement State Report - Process Gauge Shutter Handle Broke |
Event Description | On the afternoon of 3/17/09, while closing the shutter of a Ohmart/Vega SH-F1 level detection gauge, the handle separated from the shutter closure device. The gauge contains a 10 milliCurie Cesium (Cs) - 137 source serial # 5747 GK. The license can not confirm the exact position of the shutter, but they are sure that it is not closed yet. Lubricants have been used on the shutter mechanism to aid in its operation. The licensee will continue their attempts to close the shutter on 3/18/09. If unable to close, they will request assistance from the manufacturer. Additional information will be provided as it is received.
Texas Event: I-8620
The Radiation Safety Officer notified the [State of Texas] that the gauge had not been fully closed yet, but area dose rates were normal therefore the gauge does not create additional risk of exposure to their workers. Notified R4DO (Hay) and FSME EO (Camper).
The licensee reported [to the State of Texas] that on April 28, 2009, a technician from the manufacturer installed a shield over the source and removed the gauge from the vessel. The gauge has been placed in a radioactive material storage area until it can be packaged and returned to the manufacturer. Notified R4DO (Pick) and FSME EO (McIntosh). |
Where | |
---|---|
Union Carbide Corporation Seadrift, Texas (NRC Region 4) | |
License number: | 00051 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+28.73 h1.197 days <br />0.171 weeks <br />0.0394 months <br />) | |
Opened: | Art Tucker 09:44 Mar 18, 2009 |
NRC Officer: | Mark Abramovitz |
Last Updated: | May 5, 2009 |
44912 - NRC Website | |
Union Carbide Corporation with Agreement State | |
WEEKMONTHYEARENS 569172024-01-09T06:00:0009 January 2024 06:00:00
[Table view]Agreement State Agreement State - Shutter Stuck in Open Position ENS 566212023-07-12T05:00:00012 July 2023 05:00:00 Agreement State Stuck Open Shutter ENS 557012022-01-10T21:35:00010 January 2022 21:35:00 Agreement State Nuclear Gauge Holder Broken Handle ENS 509062015-03-17T05:00:00017 March 2015 05:00:00 Agreement State Agreement State Report - Ohmart Sh-F2 Gauge Shutter Handle Pin Sheared ENS 509052015-03-04T05:00:0004 March 2015 05:00:00 Agreement State Agreement State Report - Ohmart Shlm-Cr3 Cable Detached from Source ENS 502012014-06-16T05:00:00016 June 2014 05:00:00 Agreement State Agreement State Report - Stuck Shutters ENS 500352014-04-11T05:00:00011 April 2014 05:00:00 Agreement State Agreement State Report - Stuck Shutter ENS 468502011-05-11T05:00:00011 May 2011 05:00:00 Agreement State Agreement State Report - Shutter Stuck Open on Nuclear Gauge ENS 468102011-05-01T05:00:0001 May 2011 05:00:00 Agreement State Agreement State Report - Stuck Shutter on Ohmart/Vega Model Gauge ENS 449122009-03-17T05:00:00017 March 2009 05:00:00 Agreement State Agreement State Report - Process Gauge Shutter Handle Broke ENS 444522008-08-29T05:00:00029 August 2008 05:00:00 Agreement State Agreement State Report - Level Gauge Shutter Malfunction 2024-01-09T06:00:00 | |