ML18145A249: Difference between revisions
StriderTol (talk | contribs) Created page by program invented by StriderTol |
StriderTol (talk | contribs) Created page by program invented by StriderTol |
||
| Line 17: | Line 17: | ||
=Text= | =Text= | ||
{{#Wiki_filter:Adam C. Heflin, President, Chief Executive Officer, and Chief Nuclear Officer UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 1600 EAST LAMAR BOULEVARD ARLINGTON, TEXAS 76011-4511 May 29, 2018 Wolf Creek Nuclear Operating Corporation P.O. Box411 Burlington, KS 66839 SUBJECT: ERRATA FOR WOLF CREEK NUCLEAR OPERATING CORPORATION -NOTIFICATION OF INSPECTION (NRC INSPECTION REPORT 05000482/2018002) AND REQUEST FOR INFORMATION Dear Mr. Heflin: It was identified that the notification sent to you dated April 25, 2018 (NRC's Agencywide Documents Access and Management System (ADAMS) Accession No. ML18116A613) improperly listed the inspection report number as 05000482/2018002. The correct inspection report number is 05000482/2018003. Please note none of the content of the request for information has changed. The NRC has reissued the notification in its entirety to correct this error. This fetter, its enclosure, and your response (if any) will be made available for public inspection and copying at http:/!www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, "Public Inspections, Exemptions, Requests for Withholding." Docket No. 50-482 License No. NPF-42 Enclosure: Sincerely, IRA/ Vincent G. Gaddy, Chief Operations Branch Division of Reactor Safety WOLF CREEK NUCLEAR OPERA TING CORPORATION -NOTIFICATION OF INSPECTION (NRC INSPECTION REPORT 05000482/2018003) AND REQUEST FOR INFORMATION cc: Electronic Distribution | {{#Wiki_filter:Adam C. Heflin, President, | ||
Chief Executive | |||
Officer, | |||
and Chief Nuclear Officer UNITED STATES NUCLEAR REGULATORY | |||
COMMISSION | |||
REGION IV 1600 EAST LAMAR BOULEVARD | |||
ARLINGTON, | |||
TEXAS 76011-4511 | |||
May 29, 2018 Wolf Creek Nuclear Operating | |||
Corporation | |||
P.O. Box411 Burlington, | |||
KS 66839 SUBJECT: | |||
ERRATA FOR WOLF CREEK NUCLEAR OPERATING | |||
CORPORATION | |||
-NOTIFICATION | |||
OF INSPECTION | |||
(NRC INSPECTION | |||
REPORT 05000482/2018002) | |||
AND REQUEST FOR INFORMATION | |||
Dear Mr. Heflin: It was identified | |||
that the notification | |||
sent to you dated April 25, 2018 (NRC's Agencywide | |||
Documents | |||
Access and Management | |||
System (ADAMS) Accession | |||
No. ML18116A613) | |||
improperly | |||
listed the inspection | |||
report number as 05000482/2018002. | |||
The correct inspection | |||
report number is 05000482/2018003. | |||
Please note none of the content of the request for information has changed. | |||
The NRC has reissued | |||
the notification | |||
in its entirety | |||
to correct this error. This fetter, its enclosure, | |||
and your response | |||
(if any) will be made available | |||
for public inspection | |||
and copying at http:/!www.nrc.gov/reading-rm/adams.html | |||
and at the NRC Public Document | |||
Room in accordance | |||
with 10 CFR 2.390, "Public Inspections, | |||
Exemptions, | |||
Requests | |||
for Withholding." | |||
Docket No. 50-482 License No. NPF-42 Enclosure: | |||
Sincerely, | |||
IRA/ Vincent G. Gaddy, Chief Operations | |||
Branch Division | |||
of Reactor Safety WOLF CREEK NUCLEAR OPERA TING CORPORATION | |||
-NOTIFICATION | |||
OF INSPECTION | |||
(NRC INSPECTION | |||
REPORT 05000482/2018003) | |||
AND REQUEST FOR INFORMATION | |||
cc: Electronic | |||
Distribution | |||
A. Heflin 2 ERRATA FOR WOLF CREEK NUCLEAR OPERATING | |||
CORPORATION | |||
-NOTIFICATION | |||
OF INSPECTION | |||
(NRC INSPECTION | |||
REPORT 05000482/2018002) | |||
AND REQUEST FOR INFORMATION- | |||
DATED MAY 29, 2018 DISTRIBUTION: | |||
KKennedy, | |||
ORA SMorris, | |||
ORA TVegel, DRP Rlantz, DRP MShaffer, | |||
DRS JClark, DRS DDodson, | |||
DRP FThomas, | |||
DRP NTaylor, | |||
DRP DProulx, | |||
DRP JMelfi,DRP | |||
ECombs, DRP SGalemore, | |||
DRP VDricks, | |||
ORA BSingal, | |||
NRR GGeorge, | |||
DRS EUribe, DRS MHerrera, | |||
DRMA R4Enforcement | |||
SKirkwood, | |||
OGC JWeil, OWFN AMoreno, | |||
OWFN JBowen, OEDO BMaier, ORA ADAMS ACCESSION | |||
NUMBER: ML 18145A249 SUNSI Review [&] Non-Sensitive Publicly | |||
Available | |||
Bv: JCK CJ Sensitive | |||
CJ Non-Publiclv | |||
Available OFFICE SOE:OB | |||
C:OB NAME JKiridand | |||
VGaddy SIGNATURE | |||
IRA/ IRA/ DATE 05/29/18 | |||
05/29/18 | |||
OFFICIAL | |||
RECORD COPY Keyword: | |||
NRC-002 | |||
Adam C. Heflin, President, | |||
Chief Executive | |||
Officer, | |||
and Chief Nuclear Officer UNITED STATES NUCLEAR REGULATORY | |||
COMMISSION | |||
REGJON IV 1600 EAST LAMAR BOULEVARD | |||
ARLINGTON. | |||
TEXAS 76011-4511 | |||
May 29, 2018 Wolf Creek Nuclear Operating | |||
Corporation | |||
P.O. Box411 Burlington, | |||
KS 66839 SUBJECT: | |||
WOLF CREEK NUCLEAR OPERATING | |||
CORPORATION | |||
-NOTIFICATION | |||
OF INSPECTION | |||
(NRC INSPECTION | |||
REPORT 05000482/2018003) | |||
AND REQUEST FOR INFORMATION | |||
Dear Mr. Heflin: The purpose of this letter is to notify you that the U.S. Nuclear Regulatory | |||
Commission | |||
(NRC) staff will conduct a biennial | |||
requalification | |||
inspection | |||
at the Wolf Creek Nuclear Operating | |||
Corporation | |||
from June 4 -7, 2018. The inspection | |||
will consist of two reactor inspectors | |||
from the NRC's Region IV office for one week. The inspection | |||
will be conducted | |||
in accordance | |||
with the NRC Inspection | |||
Procedure | |||
{IP) 71111.11 | |||
B, "Licensed | |||
Operator | |||
Requalification | |||
Program." | |||
Experience | |||
has shown that this inspection | |||
is a resource | |||
intensive | |||
inspection | |||
both for the NRC inspectors | |||
and your staff. In order to minimize | |||
the impact to your on-site resources | |||
and to ensure a productive | |||
inspection, | |||
we have enclosed | |||
a request for documents | |||
needed for this inspection. | |||
These documents | |||
have been divided into three groups. The first group (Section | |||
A of the enclosure) | |||
identifies | |||
information | |||
to be provided | |||
prior to the inspection | |||
to ensure that the inspectors | |||
are adequately | |||
prepared. | |||
The second group (Section | |||
B of the enclosure) | |||
identifies | |||
the information | |||
the inspectors | |||
will need upon arrival at the site. The third group {Section | |||
C of this enclosure) | |||
identifies | |||
the items which are necessary | |||
to close out the inspection | |||
and are usually sent a few weeks after the team has left the site. It is important | |||
that all of these documents | |||
are up-to-date | |||
and complete | |||
in order to minimize | |||
the number of additional | |||
documents | |||
requested | |||
during the preparation | |||
and/or the on-site portions | |||
of the inspection. | |||
We have discussed | |||
the schedule | |||
for these inspection | |||
activities | |||
with your staff and understand | |||
that our regulatory | |||
contact for this inspection | |||
will be Ms. Lucille Stone. Our inspection | |||
dates are subject to change based on your updated schedule | |||
of examination | |||
activities. | |||
If there are any questions | |||
about this inspection | |||
or the material | |||
requested, | |||
please contact the lead inspector | |||
, John Kirkland, | |||
at (817) 200-1771 | |||
(John.Kirkland@nrc.gov | |||
). This letter does not contain new or amended information | |||
collection | |||
requirements | |||
subject To the Paperwork | |||
Reduction | |||
Act of 1995 (44 U.S.C. 3501 et seq.). Existing | |||
information | |||
collection | |||
requirements | |||
were approved | |||
by the Office of Management | |||
and Budget, control number 3150-0018. | |||
A. Heflin 2 The NRC may not conduct or sponsor, | |||
and a person is not required | |||
to respond to, a request for information | |||
or an information | |||
collection | |||
requirement | |||
unless the requesting | |||
document | |||
displays | |||
a currently | |||
valid Office of Management | |||
and Budget control number. In accordance | |||
with 10 CFR 2.390 of the NRC's "Agency Rules of Practice," | |||
a copy of this letter and its enclosure | |||
will be available | |||
electronically | |||
for public inspection | |||
in the NRC Public Document | |||
Room or from the Publicly | |||
Available | |||
Records (PARS) component | |||
of NRC's document | |||
system (ADAMS). | |||
ADAMS is accessible | |||
from the NRC web site at | |||
rm/adams.html | |||
(the Public Electronic | |||
Reading Room). Docket No. 50-482 License No. NPF-42 Enclosure: | |||
Request for Information | |||
cc: Electronic | |||
Distribution | |||
Sincerely, | |||
IRA! Vincent G. Gaddy, Chief Operations | |||
Branch Division | |||
of Reactor Safety | |||
Inspection | |||
Report: Inspection | |||
Dates: Initial Request for Information | |||
Biennial | |||
Requalification | |||
Inspection | |||
Wolf Creek Generating | |||
Station 05000482/2018003 | |||
June 4-7, 2018 Inspection | |||
Procedure: | |||
IP 71111.11 | |||
B, "Licensed | |||
Operator | |||
Requalification | |||
Program" | |||
Lead Inspector: | |||
John Kirkland, | |||
Senior Operations | |||
Engineer | |||
A. The following | |||
information | |||
is requested | |||
In order to support inspection | |||
preparation | |||
activities. | |||
These items are fisted by section as they appear in the inspection | |||
module (ie 2.02, 2.04, | |||
etc). Requested | |||
materf als should be sent either electronically | |||
or CD/DVD ( do not send USB drives) in order to arrive at the Region IV office no later than May 14, 2018. * Electronically: | |||
To: John.Kirkland@nrc.gov | |||
cc: Clyde.Osterholtz@nrc.gov | |||
* CD/DVD to: U.S. Nuclear Regulatory | |||
Commission | |||
Region IV General Bequests: | |||
ATTN: John Kirkland | |||
1600 E. Lamar Blvd Arlington, | |||
TX 76011 * List of licensed | |||
operators | |||
(SRO and RO) by crew (operating | |||
and staff) * Training | |||
and Operations | |||
Department | |||
organization | |||
charts (with qualified | |||
LOR evaluators | |||
identified) | |||
* Procedures | |||
that identify | |||
process for revising | |||
and maintaining | |||
LO continuing | |||
training | |||
program up-to-date | |||
* List of outstanding | |||
LOR program changes * List of plant events and industry | |||
operating | |||
experience | |||
incorporated | |||
into LOR program since last BRQ * Audits and/or self-assessment | |||
reports addressing | |||
the licensed | |||
operator | |||
requalification | |||
training | |||
program * Last 2-years of simulator | |||
review committee | |||
(or equivalent) | |||
meeting minutes Enclosure | |||
* Last 2-years of CRC (or equivalent) | |||
meeting minutes 2.3 Biennial | |||
Regualification | |||
Written Examination | |||
Qual!h'. | |||
* The current and approved | |||
biennial | |||
written examination | |||
schedule | |||
* The current requalification | |||
cycle written examination | |||
results for both SRO and RO that have already been administered | |||
up to the week prior to the inspection | |||
team arrival on-site * All.written | |||
examinations | |||
that have been approved | |||
for administration | |||
up to and including | |||
the week before the inspection | |||
team is on-site. | |||
This will need to have adequate | |||
password | |||
protection | |||
if e-mailed | |||
or double envelope | |||
protection | |||
if mailed via regular mail per NUREG-1021. | |||
* The current requalification | |||
cycle examination | |||
methodology | |||
(sample plan} 2.4 Annual Regualification | |||
Operating | |||
Test Quality 2.5 2.6 * The schedule | |||
for the operating | |||
tests (JPMs and scenarios) | |||
to be given the week of June 4, 2018 * The operating | |||
tests (JPMs and scenarios) | |||
(password | |||
protected | |||
and provide separately | |||
via telephone | |||
at later date) to be given the week of June 4, 2018 * Current requalification | |||
cycle operating | |||
tests (SRO and RO) and results up to the week prior to the inspection | |||
team arrival on-site (NIA if the inspection | |||
week is the first week of testing) | |||
* All.of the previous | |||
year's NRC required | |||
annual operating | |||
tests * Current requalification | |||
cycle operating | |||
test methodology | |||
(sample plan) * All portions | |||
of the updated Final Safety Analysis | |||
Report (FSAR) that identify | |||
operator | |||
response | |||
times for time critical | |||
operator | |||
actions Licensee | |||
Admin of Requalification | |||
Exams * All procedures | |||
used to administer | |||
the annual operating | |||
test * All procedures | |||
used to assess operator | |||
perfomiance | |||
* All procedures | |||
that describe | |||
conduct of simulator | |||
training | |||
* All procedures | |||
used to test, operate, | |||
and maintain | |||
the simulator | |||
Regualification | |||
Examination | |||
Secur~ * Submit any tracking | |||
tools that you use as a means to prevent excessive | |||
overlap on the written examinations | |||
and also meet the intent of sampling | |||
all required | |||
topics on a periodic | |||
basis * Submit any tracking | |||
tools that you use as a means to prevent excessive | |||
overlap on 2 | |||
the operating | |||
tests and also meet the intent of sampling | |||
all required | |||
malfunctions | |||
(including | |||
major events, instrument/component | |||
malfunctions, | |||
TS calls, etc.) on a periodic | |||
basis * All procedures | |||
that describe | |||
examination | |||
security, | |||
including | |||
procedures | |||
used to develop the examinations | |||
that include guidelines | |||
on overlap between examinations | |||
in current exam cycle tests and prior year examinations | |||
* List of all condition | |||
reports since the last biennial | |||
requalification | |||
inspection | |||
related to examination | |||
security | |||
and overlap 2.7 Licensee | |||
Remedial | |||
Training | |||
Program 2.8 2.9 * List of remedial | |||
training | |||
conducted | |||
or planned since last requalification | |||
exams (includes | |||
training | |||
provided | |||
to operators | |||
to enable passing requalification | |||
exams and training | |||
provided | |||
to correct generic or individual | |||
weaknesses | |||
observed | |||
during previous | |||
requalification | |||
exam cycle) * Remediation | |||
plans (lesson plans, reference | |||
materials, | |||
and attendance | |||
documentation) | |||
Conformance | |||
with Operator | |||
License Conditions | |||
* All procedures | |||
and program documentation | |||
for maintaining | |||
active operator | |||
licenses, | |||
tracking | |||
training | |||
attendance, | |||
and ensuring | |||
medical fitness of licensed | |||
operators | |||
* All procedures | |||
and associated | |||
documentation | |||
that supports | |||
reactivation | |||
of any SRO/RO license (operating | |||
or staff crew) since the last biennial | |||
inspection | |||
Simulator | |||
Performance | |||
* For the following | |||
cases, send the most recent transient | |||
test packages, | |||
which may be electronic | |||
or in paper single test packages, | |||
and shall be complete | |||
with test procedures | |||
for each test, the acceptance | |||
criteria, | |||
and results. | |||
For each transient | |||
test, the reference chart | |||
should be included | |||
or an equivalent | |||
subject matter expert review versus the simulator | |||
results with a write-up | |||
for any differences | |||
beyond the ANSI 3.5 standard | |||
requirements. | |||
o Transient | |||
test 1, manual reactor trip o Transient | |||
test 5, trip of any single reactor coolant pump o Transient | |||
test 8, maximum size RCS rupture combined | |||
with loss of all offsite power o Steady state tests for low power * SBT Packages | |||
for any three scenarios | |||
used for the 2017 Annual Requalification | |||
Operating | |||
Test 3 | |||
* All Simulator | |||
Management | |||
and Configuration | |||
Procedures | |||
if not already provided | |||
for Section 02.05 above * Simulator | |||
Discrepancy | |||
Report (DR) summacx list for all open DRs. For closed DRs, summary list for those items closed between June 2016 to May 2018 * Malfunction | |||
tests for loss of condenser | |||
vacuum and reactor pressure | |||
control system failure. | |||
If these are included | |||
in an SBT package then the review of that package would be acceptable | |||
* Two examples | |||
of primary parameters | |||
tested in order to verify core physics parameters. | |||
The applicable | |||
reference | |||
grf}phs from the plant physics data book (electronic | |||
or other means as available) | |||
should also be included | |||
as well as the test procedures | |||
used and the acceptance | |||
criteria | |||
with results. | |||
* All simulator | |||
modification | |||
packages | |||
that are on hold, delayed, | |||
or just not completed | |||
in the last 2-years * A list of simulator | |||
modification | |||
packages | |||
completed | |||
in the last 2-year window 2.10 Problem Identification | |||
and Resolution * A summary report of all condition | |||
reports related to operator | |||
actions/errors | |||
in the control room * Any revised requalification | |||
training | |||
that was based on licensed | |||
operator | |||
performance | |||
issues B. The following | |||
information | |||
is requested | |||
in order to support the on-site inspection | |||
activities. | |||
Requested | |||
materials | |||
should be available | |||
to the inspection | |||
team, either electronically | |||
or hardcopy, | |||
upon site arrival on June 4, 2018. 2.2 2.8 2.9 Exam Results / 02.03 and 02.04: Written Exam and Op Test Qualit'l | |||
* All Operating | |||
tests (JPMs and scenarios) | |||
to be given in all subsequent | |||
weeks after on-site week * All results up to the day the team leaves the site Conformance | |||
with Operator | |||
License Conditions | |||
* Access to licensed | |||
operators' | |||
records ( operating | |||
and staff crews) * Access to licensed | |||
operators' | |||
training | |||
attendance | |||
records * Access to licensed | |||
operators' | |||
medical records Simulator | |||
Performance | |||
* Simulator | |||
discrepancy | |||
reports (DRs) from June 2016 to May 2018. This should include all open DR's and DR's that have been closed, including | |||
the documentation/justification | |||
for closure. | |||
4 | |||
* Acceptance | |||
test documentation, | |||
including | |||
hardware | |||
and software | |||
model revisions | |||
at the time of acceptance | |||
(as available) | |||
* Documentation | |||
that validates | |||
current models, including | |||
the thermal*hydraulics | |||
and neutronics | |||
models, to the actual plant * All current model deficiencies, | |||
including | |||
FSAR vs. Design differences | |||
in the simulator | |||
(any documentation | |||
on this) * Summary list of modifications | |||
from June 2016 to May 2018 * Plant modifications | |||
(both hardware | |||
and software) | |||
completed | |||
on the simulator | |||
by due date from June 2016 to May 2018 * Simulator | |||
Differences | |||
Lesson plan used in training | |||
(current | |||
to June 4, 2018) * The complete | |||
book of all simulator | |||
annual performance | |||
test packages | |||
(usually | |||
in a single book, but may be electronic | |||
or in single test packages), | |||
complete | |||
with all transient | |||
tests, steady state tests, and malfunction | |||
tests. This should also include the test procedures | |||
for each test, the acceptance | |||
criteria, | |||
and results. | |||
For each transient | |||
test, the reference | |||
chart should be included | |||
or an equivalent | |||
subject matter expert review versus the simulator | |||
results with a write-up | |||
for any differences | |||
beyond the ANSI standard | |||
requirements. | |||
* All test packages | |||
used to verify core physics parameters. | |||
The applicable | |||
reference | |||
graphs from the plant physics data book ( electronic | |||
or other means as available) | |||
should also be included | |||
as well as the test procedures | |||
used and the acceptance | |||
criteria | |||
with results. | |||
* All simulator | |||
test, configuration | |||
management, | |||
and related documents | |||
available | |||
in the room for inspectors | |||
to review. This includes | |||
training | |||
needs analysis | |||
packages, | |||
simulator | |||
review committee | |||
meeting minutes, | |||
etc. * Current copy of ANSI 3.5 standard | |||
you are committed | |||
to for simulator | |||
testing 2.10 Problem Identification | |||
and Resolution | |||
* All condition | |||
reports related to operator | |||
actions/errors | |||
in the control room C. Wolf Creek Nuclear Operating | |||
Corporation | |||
is required | |||
to send the final results summary, | |||
and any remaining | |||
exams and operating | |||
tests that have not been reviewed | |||
to the Regional | |||
office lead inspector | |||
for this inspection | |||
for final review and comparison | |||
against the significance | |||
determination | |||
tools in order to communicate | |||
the exit results for the inspection. | |||
5 | |||
}} | }} | ||
Revision as of 22:15, 28 June 2018
| ML18145A249 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 05/29/2018 |
| From: | Vincent Gaddy Operations Branch IV |
| To: | Heflin A C Wolf Creek |
| References | |
| IR 2018002 | |
| Download: ML18145A249 (9) | |
See also: IR 05000482/2018002
Text
Adam C. Heflin, President,
Chief Executive
Officer,
and Chief Nuclear Officer UNITED STATES NUCLEAR REGULATORY
COMMISSION
REGION IV 1600 EAST LAMAR BOULEVARD
ARLINGTON,
TEXAS 76011-4511
May 29, 2018 Wolf Creek Nuclear Operating
Corporation
P.O. Box411 Burlington,
KS 66839 SUBJECT:
ERRATA FOR WOLF CREEK NUCLEAR OPERATING
CORPORATION
-NOTIFICATION
OF INSPECTION
(NRC INSPECTION
REPORT 05000482/2018002)
AND REQUEST FOR INFORMATION
Dear Mr. Heflin: It was identified
that the notification
sent to you dated April 25, 2018 (NRC's Agencywide
Documents
Access and Management
System (ADAMS) Accession
No. ML18116A613)
improperly
listed the inspection
report number as 05000482/2018002.
The correct inspection
report number is 05000482/2018003.
Please note none of the content of the request for information has changed.
The NRC has reissued
the notification
in its entirety
to correct this error. This fetter, its enclosure,
and your response
(if any) will be made available
for public inspection
and copying at http:/!www.nrc.gov/reading-rm/adams.html
and at the NRC Public Document
Room in accordance
with 10 CFR 2.390, "Public Inspections,
Exemptions,
Requests
for Withholding."
Docket No. 50-482 License No. NPF-42 Enclosure:
Sincerely,
IRA/ Vincent G. Gaddy, Chief Operations
Branch Division
of Reactor Safety WOLF CREEK NUCLEAR OPERA TING CORPORATION
-NOTIFICATION
OF INSPECTION
(NRC INSPECTION
REPORT 05000482/2018003)
AND REQUEST FOR INFORMATION
cc: Electronic
Distribution
A. Heflin 2 ERRATA FOR WOLF CREEK NUCLEAR OPERATING
CORPORATION
-NOTIFICATION
OF INSPECTION
(NRC INSPECTION
REPORT 05000482/2018002)
AND REQUEST FOR INFORMATION-
DATED MAY 29, 2018 DISTRIBUTION:
KKennedy,
ORA SMorris,
ORA TVegel, DRP Rlantz, DRP MShaffer,
DRP FThomas,
DRP NTaylor,
DRP DProulx,
ECombs, DRP SGalemore,
DRP VDricks,
ORA BSingal,
NRR GGeorge,
DRMA R4Enforcement
SKirkwood,
OWFN JBowen, OEDO BMaier, ORA ADAMS ACCESSION
NUMBER: ML 18145A249 SUNSI Review [&] Non-Sensitive Publicly
Available
Bv: JCK CJ Sensitive
CJ Non-Publiclv
Available OFFICE SOE:OB
C:OB NAME JKiridand
VGaddy SIGNATURE
IRA/ IRA/ DATE 05/29/18
05/29/18
OFFICIAL
RECORD COPY Keyword:
Adam C. Heflin, President,
Chief Executive
Officer,
and Chief Nuclear Officer UNITED STATES NUCLEAR REGULATORY
COMMISSION
REGJON IV 1600 EAST LAMAR BOULEVARD
ARLINGTON.
TEXAS 76011-4511
May 29, 2018 Wolf Creek Nuclear Operating
Corporation
P.O. Box411 Burlington,
KS 66839 SUBJECT:
WOLF CREEK NUCLEAR OPERATING
CORPORATION
-NOTIFICATION
OF INSPECTION
(NRC INSPECTION
REPORT 05000482/2018003)
AND REQUEST FOR INFORMATION
Dear Mr. Heflin: The purpose of this letter is to notify you that the U.S. Nuclear Regulatory
Commission
(NRC) staff will conduct a biennial
requalification
inspection
at the Wolf Creek Nuclear Operating
Corporation
from June 4 -7, 2018. The inspection
will consist of two reactor inspectors
from the NRC's Region IV office for one week. The inspection
will be conducted
in accordance
with the NRC Inspection
Procedure
{IP) 71111.11
B, "Licensed
Operator
Requalification
Program."
Experience
has shown that this inspection
is a resource
intensive
inspection
both for the NRC inspectors
and your staff. In order to minimize
the impact to your on-site resources
and to ensure a productive
inspection,
we have enclosed
a request for documents
needed for this inspection.
These documents
have been divided into three groups. The first group (Section
A of the enclosure)
identifies
information
to be provided
prior to the inspection
to ensure that the inspectors
are adequately
prepared.
The second group (Section
B of the enclosure)
identifies
the information
the inspectors
will need upon arrival at the site. The third group {Section
C of this enclosure)
identifies
the items which are necessary
to close out the inspection
and are usually sent a few weeks after the team has left the site. It is important
that all of these documents
are up-to-date
and complete
in order to minimize
the number of additional
documents
requested
during the preparation
and/or the on-site portions
of the inspection.
We have discussed
the schedule
for these inspection
activities
with your staff and understand
that our regulatory
contact for this inspection
will be Ms. Lucille Stone. Our inspection
dates are subject to change based on your updated schedule
of examination
activities.
If there are any questions
about this inspection
or the material
requested,
please contact the lead inspector
at (817) 200-1771
(John.Kirkland@nrc.gov
). This letter does not contain new or amended information
collection
requirements
subject To the Paperwork
Reduction
Act of 1995 (44 U.S.C. 3501 et seq.). Existing
information
collection
requirements
were approved
by the Office of Management
and Budget, control number 3150-0018.
A. Heflin 2 The NRC may not conduct or sponsor,
and a person is not required
to respond to, a request for information
or an information
collection
requirement
unless the requesting
document
displays
a currently
valid Office of Management
and Budget control number. In accordance
with 10 CFR 2.390 of the NRC's "Agency Rules of Practice,"
a copy of this letter and its enclosure
will be available
electronically
for public inspection
in the NRC Public Document
Room or from the Publicly
Available
Records (PARS) component
of NRC's document
system (ADAMS).
ADAMS is accessible
from the NRC web site at
rm/adams.html
(the Public Electronic
Reading Room). Docket No. 50-482 License No. NPF-42 Enclosure:
Request for Information
cc: Electronic
Distribution
Sincerely,
IRA! Vincent G. Gaddy, Chief Operations
Branch Division
of Reactor Safety
Inspection
Report: Inspection
Dates: Initial Request for Information
Biennial
Requalification
Inspection
Wolf Creek Generating
Station 05000482/2018003
June 4-7, 2018 Inspection
Procedure:
B, "Licensed
Operator
Requalification
Program"
Lead Inspector:
Senior Operations
Engineer
A. The following
information
is requested
In order to support inspection
preparation
activities.
These items are fisted by section as they appear in the inspection
module (ie 2.02, 2.04,
etc). Requested
materf als should be sent either electronically
or CD/DVD ( do not send USB drives) in order to arrive at the Region IV office no later than May 14, 2018. * Electronically:
To: John.Kirkland@nrc.gov
cc: Clyde.Osterholtz@nrc.gov
- CD/DVD to: U.S. Nuclear Regulatory
Commission
Region IV General Bequests:
ATTN: John Kirkland
1600 E. Lamar Blvd Arlington,
TX 76011 * List of licensed
operators
(SRO and RO) by crew (operating
and staff) * Training
and Operations
Department
organization
charts (with qualified
LOR evaluators
identified)
- Procedures
that identify
process for revising
and maintaining
LO continuing
training
program up-to-date
- List of outstanding
LOR program changes * List of plant events and industry
operating
experience
incorporated
into LOR program since last BRQ * Audits and/or self-assessment
reports addressing
the licensed
operator
requalification
training
program * Last 2-years of simulator
review committee
(or equivalent)
meeting minutes Enclosure
- Last 2-years of CRC (or equivalent)
meeting minutes 2.3 Biennial
Regualification
Written Examination
Qual!h'.
- The current and approved
biennial
written examination
schedule
- The current requalification
cycle written examination
results for both SRO and RO that have already been administered
up to the week prior to the inspection
team arrival on-site * All.written
examinations
that have been approved
for administration
up to and including
the week before the inspection
team is on-site.
This will need to have adequate
password
protection
if e-mailed
or double envelope
protection
if mailed via regular mail per NUREG-1021.
- The current requalification
cycle examination
methodology
(sample plan} 2.4 Annual Regualification
Operating
Test Quality 2.5 2.6 * The schedule
for the operating
tests (JPMs and scenarios)
to be given the week of June 4, 2018 * The operating
tests (JPMs and scenarios)
(password
protected
and provide separately
via telephone
at later date) to be given the week of June 4, 2018 * Current requalification
cycle operating
tests (SRO and RO) and results up to the week prior to the inspection
team arrival on-site (NIA if the inspection
week is the first week of testing)
- All.of the previous
year's NRC required
annual operating
tests * Current requalification
cycle operating
test methodology
(sample plan) * All portions
of the updated Final Safety Analysis
Report (FSAR) that identify
operator
response
times for time critical
operator
actions Licensee
Admin of Requalification
Exams * All procedures
used to administer
the annual operating
test * All procedures
used to assess operator
perfomiance
- All procedures
that describe
conduct of simulator
training
- All procedures
used to test, operate,
and maintain
the simulator
Regualification
Examination
Secur~ * Submit any tracking
tools that you use as a means to prevent excessive
overlap on the written examinations
and also meet the intent of sampling
all required
topics on a periodic
basis * Submit any tracking
tools that you use as a means to prevent excessive
overlap on 2
the operating
tests and also meet the intent of sampling
all required
malfunctions
(including
major events, instrument/component
malfunctions,
TS calls, etc.) on a periodic
basis * All procedures
that describe
examination
security,
including
procedures
used to develop the examinations
that include guidelines
on overlap between examinations
in current exam cycle tests and prior year examinations
- List of all condition
reports since the last biennial
requalification
inspection
related to examination
security
and overlap 2.7 Licensee
Remedial
Training
Program 2.8 2.9 * List of remedial
training
conducted
or planned since last requalification
exams (includes
training
provided
to operators
to enable passing requalification
exams and training
provided
to correct generic or individual
weaknesses
observed
during previous
requalification
exam cycle) * Remediation
plans (lesson plans, reference
materials,
and attendance
documentation)
Conformance
with Operator
License Conditions
- All procedures
and program documentation
for maintaining
active operator
licenses,
tracking
training
attendance,
and ensuring
medical fitness of licensed
operators
- All procedures
and associated
documentation
that supports
reactivation
of any SRO/RO license (operating
or staff crew) since the last biennial
inspection
Simulator
Performance
- For the following
cases, send the most recent transient
test packages,
which may be electronic
or in paper single test packages,
and shall be complete
with test procedures
for each test, the acceptance
criteria,
and results.
For each transient
test, the reference chart
should be included
or an equivalent
subject matter expert review versus the simulator
results with a write-up
for any differences
beyond the ANSI 3.5 standard
requirements.
test 1, manual reactor trip o Transient
test 5, trip of any single reactor coolant pump o Transient
test 8, maximum size RCS rupture combined
with loss of all offsite power o Steady state tests for low power * SBT Packages
for any three scenarios
used for the 2017 Annual Requalification
Operating
Test 3
- All Simulator
Management
and Configuration
Procedures
if not already provided
for Section 02.05 above * Simulator
Discrepancy
Report (DR) summacx list for all open DRs. For closed DRs, summary list for those items closed between June 2016 to May 2018 * Malfunction
tests for loss of condenser
vacuum and reactor pressure
control system failure.
If these are included
in an SBT package then the review of that package would be acceptable
- Two examples
of primary parameters
tested in order to verify core physics parameters.
The applicable
reference
grf}phs from the plant physics data book (electronic
or other means as available)
should also be included
as well as the test procedures
used and the acceptance
criteria
with results.
- All simulator
modification
packages
that are on hold, delayed,
or just not completed
in the last 2-years * A list of simulator
modification
packages
completed
in the last 2-year window 2.10 Problem Identification
and Resolution * A summary report of all condition
reports related to operator
actions/errors
in the control room * Any revised requalification
training
that was based on licensed
operator
performance
issues B. The following
information
is requested
in order to support the on-site inspection
activities.
Requested
materials
should be available
to the inspection
team, either electronically
or hardcopy,
upon site arrival on June 4, 2018. 2.2 2.8 2.9 Exam Results / 02.03 and 02.04: Written Exam and Op Test Qualit'l
- All Operating
tests (JPMs and scenarios)
to be given in all subsequent
weeks after on-site week * All results up to the day the team leaves the site Conformance
with Operator
License Conditions
- Access to licensed
operators'
records ( operating
and staff crews) * Access to licensed
operators'
training
attendance
records * Access to licensed
operators'
medical records Simulator
Performance
- Simulator
discrepancy
reports (DRs) from June 2016 to May 2018. This should include all open DR's and DR's that have been closed, including
the documentation/justification
for closure.
4
- Acceptance
test documentation,
including
hardware
and software
model revisions
at the time of acceptance
(as available)
- Documentation
that validates
current models, including
the thermal*hydraulics
and neutronics
models, to the actual plant * All current model deficiencies,
including
FSAR vs. Design differences
in the simulator
(any documentation
on this) * Summary list of modifications
from June 2016 to May 2018 * Plant modifications
(both hardware
and software)
completed
on the simulator
by due date from June 2016 to May 2018 * Simulator
Differences
Lesson plan used in training
(current
to June 4, 2018) * The complete
book of all simulator
annual performance
test packages
(usually
in a single book, but may be electronic
or in single test packages),
complete
with all transient
tests, steady state tests, and malfunction
tests. This should also include the test procedures
for each test, the acceptance
criteria,
and results.
For each transient
test, the reference
chart should be included
or an equivalent
subject matter expert review versus the simulator
results with a write-up
for any differences
beyond the ANSI standard
requirements.
- All test packages
used to verify core physics parameters.
The applicable
reference
graphs from the plant physics data book ( electronic
or other means as available)
should also be included
as well as the test procedures
used and the acceptance
criteria
with results.
- All simulator
test, configuration
management,
and related documents
available
in the room for inspectors
to review. This includes
training
needs analysis
packages,
simulator
review committee
meeting minutes,
etc. * Current copy of ANSI 3.5 standard
you are committed
to for simulator
testing 2.10 Problem Identification
and Resolution
- All condition
reports related to operator
actions/errors
in the control room C. Wolf Creek Nuclear Operating
Corporation
is required
to send the final results summary,
and any remaining
exams and operating
tests that have not been reviewed
to the Regional
office lead inspector
for this inspection
for final review and comparison
against the significance
determination
tools in order to communicate
the exit results for the inspection.
5