{{#Wiki_filter:Channel 4                                        DGK 250                                                                              main electronic rack Safety uncompensated                                  NA 31 P-1680005 ion chamber                                                                    NZ 21 (10kW)
S    0 to 1 mA NT 64 det.signal                                          reactor power            4 to 20 mA cal.                                                                                      RTP 3000 U
check                                                                                            0 to 150 %Pn 0/100%
up to                              NB 28                          P > 110%
BO2.1                                110% setback NH 32                              6 trips 8x DPDT 0...+1kV                                                                          for                                                              P > 120%
HV                                                        BO2.2 monitoring      RPS                                                                              120% power trip detector voltage error supply volt. & check monitoring      flags check &
param.
locking Par-EPROM        80C32 RAM NN 53 NZ 21 test Power Supply                                                            S-BUS Vs = 115 / 230 VAC                                                                failure NZ 12                                            NB 21 8 relays BO1.6 NB 21                                                            alarms                          add. config. alarms op. access,        adjustabele                      BO1.1-5                                (not used) 4 binary                functional            trips,              test inputs                monitoring,          status                          BO1.7                                system test re-              signals            failure                                              (to RTP 3000) calculation                                            BO1.8 recalibration,            NS 01 Release parameters,                2 key (Keys)                                                                                              channel fault    NS 01        relay test                      switches                                                                                                            system fault board control loop              Relais      chg. over                      (to RTP 3000) 2016-06-29    DBR DGK 250: Purdue Safety Channel - Block Diagram                                                                                            PJ0000396 P24 ed.1 reviewed:        approved:}}

Latest revision as of 02:54, 30 October 2019

Drawing - Dgk 250: Purdue Safety Channel - Block Diagram
ML17172A646
Person / Time
Site: Purdue University
Issue date: 06/29/2016
From:
Mirion Technologies Corp
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17172A634 List:
References
Download: ML17172A646 (1)


Text

Channel 4 DGK 250 main electronic rack Safety uncompensated NA 31 P-1680005 ion chamber NZ 21 (10kW)

S 0 to 1 mA NT 64 det.signal reactor power 4 to 20 mA cal. RTP 3000 U

check 0 to 150 %Pn 0/100%

up to NB 28 P > 110%

BO2.1 110% setback NH 32 6 trips 8x DPDT 0...+1kV for P > 120%

HV BO2.2 monitoring RPS 120% power trip detector voltage error supply volt. & check monitoring flags check &

param.

locking Par-EPROM 80C32 RAM NN 53 NZ 21 test Power Supply S-BUS Vs = 115 / 230 VAC failure NZ 12 NB 21 8 relays BO1.6 NB 21 alarms add. config. alarms op. access, adjustabele BO1.1-5 (not used) 4 binary functional trips, test inputs monitoring, status BO1.7 system test re- signals failure (to RTP 3000) calculation BO1.8 recalibration, NS 01 Release parameters, 2 key (Keys) channel fault NS 01 relay test switches system fault board control loop Relais chg. over (to RTP 3000) 2016-06-29 DBR DGK 250: Purdue Safety Channel - Block Diagram PJ0000396 P24 ed.1 reviewed: approved: