Drawing - Dak 250-g: Purdue Linear Power Channel - Block Diagram
ML17172A645
Person / Time
Site: Purdue University
Issue date: 06/29/2016
From:
Mirion Technologies Corp
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17172A634 List:
References
Download: ML17172A645 (1)


Text

Channel 3 DAK 250-g main electronic rack NZ 21.22 Linear Power change rate remark:

linear full scale:

change FS := "150%"

current/frequ.

uncompensated rate 80%FS = "120%"

converter ion chamber 73.3%FS = "110%" (default) 3.3%FS = "zero" (default)

NV 102 NI 11 low pass, log. power S NT 64 I counter lin./log.

f scaling 4 to 20 mA RTP 3000 U 0.1 pA to 1mA range, test range lin. power test (NZ12) 0 to 150% in 16 lin. ranges test (NZ12)

NH 32.51 NB 22 0...+1kV decoder detector voltage detector voltage monitoring up/down range range 2 enable control 4 bit information NR 31 relay 1 out of 16 16 relays RTP 3000 switches range indicator NB 28 2 fixed trip alarms 8x DPDT relay BO2.1 110% (73.3%FS) setback trip chg.over alarms BO2.2 120% (80% FS) pow. trip NN43 NN 53 internal voltage Power Supply monitoring fault Vs = 115 / 230 VAC status par-EPROM 80C32 RAM remark:

Due to automatic switching, the not on scale S-BUS alarm is only relevant for the lowest range 16.

Its expected to switch at approx. 1 pA.

up/down NZ 12 NB 21 enable BO1.6 alarms 8 relays NB 21 operator's BO1.1 not on scale access, adjustable 4 binary functional alarms test inputs monitoring, and BO1.7 system test status failure (to RTP 3000) re- signals BO1.8 calculation test test NS 01 Release NS 01 2 key channel fault relay (Keys) parameter settings switches Relais system fault board control loop chg. over (to RTP 3000) 2016-06-29 DBR DAK 250-g: Purdue Linear Power Channel - Block Diagram PJ0000396 P23 ed.1 reviewed: approved: