{{#Wiki_filter:July 25, 2024 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD           20852
{{#Wiki_filter:July 25, 2024 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852


==SUBJECT:==
==SUBJECT:==
Line 24: Line 24:


==Dear Members of the Technical Specifications Task Force:==
==Dear Members of the Technical Specifications Task Force:==
By {{letter dated|date=May 31, 2024|text=letter dated May 31, 2024}} (Agencywide Do cuments Access and Management System (ADAMS) Accession No. ML24152A200), you subm itted a request to the U.S. Nuclear Regulatory Commission (NRC) to incorporate Traveler TSTF-601, Revision 0, Extend Shield Building Completion Time After Refueling, into the standard technical specifications.


By {{letter dated|date=May 31, 2024|text=letter dated May 31, 2024}} (Agencywide Do  cuments Access and Management System (ADAMS) Accession No. ML24152A200), you subm  itted a request to the U.S. Nuclear Regulatory Commission (NRC) to incorporate  Traveler TSTF-601, Revision 0, Extend Shield Building Completion Time After Refueling, into the standard technical specifications.
Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the re view. You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly. The NRC st aff estimates that the review will require approximately 470 staff hours including project management time.


Section 170.21 of Title 10 of the  Code of Federal Regulations  requires that Travelers are subject to fees based on the full cost of the re  view.        You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly.       The NRC st    aff estimates that the review will require approximately 470 staff hours including project management time.
The NRC staff has completed a preliminary review of your submission and determined it is sufficiently complete and appropriate to initiate a more comprehensive review. The review will generally follow the schedule below.


The NRC staff has completed a preliminary review  of your submission and determined it is sufficiently complete and appropriate to initiate a    more comprehensive review.        The review will generally follow the schedule below.
MILESTONE SCHEDULE DATE Issue Request for Additional Information October 28, 2024 Issue Draft Safety Evaluation July 25, 2025 Issue Final Safety Evaluation December 19, 2025


MILESTONE SCHEDULE DATE Issue Request for Additional Information                                                                                                                                                                                                                                                                                                                                                                                                        October 28, 2024 Issue Draft Safety Evaluation                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            July 25, 2025 Issue Final Safety Evaluation                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          December 19, 2025
If you have any questions, please contact me at (301) 415-1774 or via email to Michelle.Honcharik@nrc.gov.
 
If you have any questions, please contact   me at (301) 415-1774 or via email to Michelle.Honcharik@nrc.gov.


Sincerely,
Sincerely,


    /RA/
/RA/
Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation
Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation


Project No. 753 cc:           See next page
Project No. 753 cc: See next page


cc:
cc:


Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD       20852 Attention: Brian D. Mann Email: brian.mann@excelservices.com
Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD 20852 Attention: Brian D. Mann Email: brian.mann@excelservices.com


Drew Richards STP Nuclear Operating Company 12090 FM 521 Mail Code: N5016 Wadsworth, TX 77483 Email: amrichards@stpegs.com
Drew Richards STP Nuclear Operating Company 12090 FM 521 Mail Code: N5016 Wadsworth, TX 77483 Email: amrichards@stpegs.com
Line 50: Line 49:
Kevin Lueshen Constellation Energy Generation 4300 Winfield Road Warrenville IL 60555 Email: kevin.lueshen@constellation.com
Kevin Lueshen Constellation Energy Generation 4300 Winfield Road Warrenville IL 60555 Email: kevin.lueshen@constellation.com


Jordan L. Vaughan Duke Energy EC07C / P.O. Box 1006 Charlotte, NC           28202 Email: jordan.vaughan@duke-energy.com
Jordan L. Vaughan Duke Energy EC07C / P.O. Box 1006 Charlotte, NC 28202 Email: jordan.vaughan@duke-energy.com


Shane Jurek 2818 Provin Oaks Ct NE Grand Rapids, MI 49525 Email: Shane.Jurek@pseg.com
Shane Jurek 2818 Provin Oaks Ct NE Grand Rapids, MI 49525 Email: Shane.Jurek@pseg.com


Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-226-EC Birmingham, AL       35242 Email: wasparkm@southernco.com
Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-226-EC Birmingham, AL 35242 Email: wasparkm@southernco.com


ML24207A182 *via email                                                                                   NRR-106 OFFICE NRR/DSS/STSB 7/25/2024 MHoncharik*
ML24207A182 *via email NRR-106 OFFICE NRR/DSS/STSB 7/25/2024 MHoncharik*
DATE 7/25/2024}}
DATE 7/25/2024}}

Revision as of 11:01, 4 October 2024

TSTF-601, Extend Shield Building Completion Time After Refueling, Acceptance Review Letter
ML24207A182
Person / Time
Site: Technical Specifications Task Force
Issue date: 07/25/2024
From: Michelle Honcharik
Office of Nuclear Reactor Regulation
To:
Technical Specifications Task Force
References
EPID L-2024-PMP-0007
Download: ML24207A182 (3)


Text

July 25, 2024 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852

SUBJECT:

ACCEPTANCE FOR REVIEW REGARDING TRAVELER TSTF-601, REVISION 0, EXTEND SHIELD BUILDING COMPLETION TIME AFTER REFUELING (EPID: L-2024-PMP-0007)

Dear Members of the Technical Specifications Task Force:

By letter dated May 31, 2024 (Agencywide Do cuments Access and Management System (ADAMS) Accession No. ML24152A200), you subm itted a request to the U.S. Nuclear Regulatory Commission (NRC) to incorporate Traveler TSTF-601, Revision 0, Extend Shield Building Completion Time After Refueling, into the standard technical specifications.

Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the re view. You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly. The NRC st aff estimates that the review will require approximately 470 staff hours including project management time.

The NRC staff has completed a preliminary review of your submission and determined it is sufficiently complete and appropriate to initiate a more comprehensive review. The review will generally follow the schedule below.

MILESTONE SCHEDULE DATE Issue Request for Additional Information October 28, 2024 Issue Draft Safety Evaluation July 25, 2025 Issue Final Safety Evaluation December 19, 2025

If you have any questions, please contact me at (301) 415-1774 or via email to Michelle.Honcharik@nrc.gov.

Sincerely,

/RA/

Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation

Project No. 753 cc: See next page

cc:

Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 Rockville, MD 20852 Attention: Brian D. Mann Email: brian.mann@excelservices.com

Drew Richards STP Nuclear Operating Company 12090 FM 521 Mail Code: N5016 Wadsworth, TX 77483 Email: amrichards@stpegs.com

Kevin Lueshen Constellation Energy Generation 4300 Winfield Road Warrenville IL 60555 Email: kevin.lueshen@constellation.com

Jordan L. Vaughan Duke Energy EC07C / P.O. Box 1006 Charlotte, NC 28202 Email: jordan.vaughan@duke-energy.com

Shane Jurek 2818 Provin Oaks Ct NE Grand Rapids, MI 49525 Email: Shane.Jurek@pseg.com

Wesley Sparkman Southern Nuclear Operating Company 3535 Colonnade Parkway / Bin N-226-EC Birmingham, AL 35242 Email: wasparkm@southernco.com

ML24207A182 *via email NRR-106 OFFICE NRR/DSS/STSB 7/25/2024 MHoncharik*

DATE 7/25/2024