| title = Locking Mechanism Malfunction | | title = Locking Mechanism Malfunction on Radiography Camera | ||
| event text = On January 10th, the radiography crew working the Kuparuk Oil Field on the North Slope of Alaska experienced a malfunctioning locking system on an INC IR-100 exposure device (serial number 6631). | | event text = On January 10th, the radiography crew working the Kuparuk Oil Field on the North Slope of Alaska experienced a malfunctioning locking system on an INC IR-100 exposure device (serial number 6631). | ||
During the shift the source was cranked in and the camera was surveyed per the proper procedure. There were no abnormal readings observed during the survey and the key was turned to the lock position. When the crank assembly was removed it was noted that the pigtail was not fully seated. | During the shift the source was cranked in and the camera was surveyed per the proper procedure. There were no abnormal readings observed during the survey and the key was turned to the lock position. When the crank assembly was removed it was noted that the pigtail was not fully seated. |
Latest revision as of 22:08, 1 March 2018
Where | |
---|---|
Kakivik Asset Management North Slope, Alaska (NRC Region 4) | |
Organization: | Kakivik Asset Management |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+1.5 h0.0625 days <br />0.00893 weeks <br />0.00205 months <br />) | |
Opened: | Keenan Remele 10:29 Jan 11, 2011 |
NRC Officer: | John Shoemaker |
Last Updated: | Jan 11, 2011 |