ENS 46533: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 01/10/2011 23:59 YST
| event date = 01/10/2011 23:59 YST
| last update date = 01/11/2011
| last update date = 01/11/2011
| title = Locking Mechanism Malfunction On Radiography Camera
| title = Locking Mechanism Malfunction on Radiography Camera
| event text = On January 10th, the radiography crew working the Kuparuk Oil Field on the North Slope of Alaska experienced a malfunctioning locking system on an INC IR-100 exposure device (serial number 6631).
| event text = On January 10th, the radiography crew working the Kuparuk Oil Field on the North Slope of Alaska experienced a malfunctioning locking system on an INC IR-100 exposure device (serial number 6631).
During the shift the source was cranked in and the camera was surveyed per the proper procedure. There were no abnormal readings observed during the survey and the key was turned to the lock position.  When the crank assembly was removed it was noted that the pigtail was not fully seated.   
During the shift the source was cranked in and the camera was surveyed per the proper procedure. There were no abnormal readings observed during the survey and the key was turned to the lock position.  When the crank assembly was removed it was noted that the pigtail was not fully seated.   

Latest revision as of 22:08, 1 March 2018

ENS 46533 +/-
Where
Kakivik Asset Management
North Slope, Alaska (NRC Region 4)
Organization: Kakivik Asset Management
Reporting
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure
Time - Person (Reporting Time:+1.5 h0.0625 days <br />0.00893 weeks <br />0.00205 months <br />)
Opened: Keenan Remele
10:29 Jan 11, 2011
NRC Officer: John Shoemaker
Last Updated: Jan 11, 2011
46533 - NRC Website