ENS 46052
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
09:00 Jun 29, 2010 | |
Title | Lock Malfunction on a Radiography Camera |
Event Description | On June 29th [at approximately 0100], the radiography crew working the Alpine Oil Field on the North Slope of Alaska experienced a malfunctioning locking system on an Industrial Nuclear Corporation (INC) IR-100 exposure device (serial number 4814).
During the night shift the locking mechanism on the exposure device would not operate properly. When the locking latch was depressed the source could not be moved to the exposed position. When retract pressure was applied, the locking device would not 'pop up', it had to be moved manually. The source never left the safe and secure position. The trained radiographer who can work on the locking mechanism decided that the camera would be tagged out and returned to the manufacturer for repair. The camera will be shipped [on today]. There was no exposure to the crew or the General Public during this incident. The IR-100 unit uses a 52 Curie Ir-192 source. Source S/N: P311. The licensee has informed Region 4. |
Where | |
---|---|
Kakivik Asset Management North Slope, Alaska (NRC Region 4) | |
License number: | 50-27667-01 |
Organization: | Kakivik Asset Management |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+4.07 h0.17 days <br />0.0242 weeks <br />0.00558 months <br />) | |
Opened: | Keenan Remele 13:04 Jun 29, 2010 |
NRC Officer: | Eric Simpson |
Last Updated: | Jun 29, 2010 |
46052 - NRC Website | |
Kakivik Asset Management with 10 CFR 30.50(b)(2) | |
WEEKMONTHYEARENS 540502019-05-05T08:18:0005 May 2019 08:18:00
[Table view]10 CFR 30.50(b)(2) Stuck Radiography Camera Source ENS 526912017-04-18T10:30:00018 April 2017 10:30:00 10 CFR 30.50(b)(2) Failure of the Radiography Camera Locking Mechanism ENS 525962017-03-07T05:00:0007 March 2017 05:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Did Not Lock in the Shielded Position When Retracted ENS 515822015-12-01T10:00:0001 December 2015 10:00:00 10 CFR 30.50(b)(2) Radiography Camera Fails to Lock Source Automatically When Retracted ENS 481192012-07-02T07:45:0002 July 2012 07:45:00 10 CFR 30.50(b)(2) Unable to Retract Source Into Radiography Camera ENS 474282011-11-10T20:10:00010 November 2011 20:10:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Completely Retract ENS 474182011-11-06T07:00:0006 November 2011 07:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Lock Malfunction ENS 465332011-01-11T08:59:00011 January 2011 08:59:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 463232010-10-10T00:00:00010 October 2010 00:00:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 462332010-09-04T08:00:0004 September 2010 08:00:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 460522010-06-29T09:00:00029 June 2010 09:00:00 10 CFR 30.50(b)(2) Lock Malfunction on a Radiography Camera ENS 460512010-06-29T08:00:00029 June 2010 08:00:00 10 CFR 30.50(b)(2) Source Locking Malfunction of Radiography Camera ENS 456482010-01-22T09:00:00022 January 2010 09:00:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 456092010-01-06T10:50:0006 January 2010 10:50:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 455442009-12-07T13:30:0007 December 2009 13:30:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 455242009-11-27T17:00:00027 November 2009 17:00:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 454962009-11-13T00:30:00013 November 2009 00:30:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 454692009-10-27T08:45:00027 October 2009 08:45:00 10 CFR 30.50(b)(2) Radiography Source Unable to Fully Retract ENS 453842009-09-27T10:00:00027 September 2009 10:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Fully Retract Into Camera ENS 437692007-11-03T23:00:0003 November 2007 23:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Fully Retract Into Camera ENS 431172007-01-13T21:30:00013 January 2007 21:30:00 10 CFR 30.50(b)(2) Failure of Radiography Camera Source to Fully Retract ENS 430672006-12-28T11:30:00028 December 2006 11:30:00 10 CFR 30.50(b)(2) Failure of Radiography Camera Source to Fully Retract ENS 426822006-03-08T08:00:0008 March 2006 08:00:00 10 CFR 30.50(b)(2) Radiography Source Pigtail Disconnected from Drive Cable 2019-05-05T08:18:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_46052&oldid=425187"