ENS 43117
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
21:30 Jan 13, 2007 | |
Title | Failure of Radiography Camera Source to Fully Retract |
Event Description | On January 13, 2006, at 12:30 am local time, while performing a radiography at the facility in Kuparuk, Alaska, the radiography camera source failed to fully retract into the shielded position. The radiographer contacted the Level 2 Radiographer who shielded the camera and was able to fully retract the source. No over-exposures occurred.
The camera is a INC Model IR-100, serial number 6631 with a source serial number of J744. The typical original Ir-192 source strength of this type of radiography camera is about 100 curies. Kakivik Asset Management has contacted the manufacturer of the camera about this occurrence and other similar occurrences. |
Where | |
---|---|
Kakivik Asset Management Anchorage, Alaska (NRC Region 4) | |
License number: | 50-27667-01 |
Organization: | Kakivik Asset Management |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+256.58 h10.691 days <br />1.527 weeks <br />0.351 months <br />) | |
Opened: | Larry Russell 14:05 Jan 24, 2007 |
NRC Officer: | Pete Snyder |
Last Updated: | Jan 24, 2007 |
43117 - NRC Website | |
Kakivik Asset Management with 10 CFR 30.50(b)(2) | |
WEEKMONTHYEARENS 540502019-05-05T08:18:0005 May 2019 08:18:00
[Table view]10 CFR 30.50(b)(2) Stuck Radiography Camera Source ENS 526912017-04-18T10:30:00018 April 2017 10:30:00 10 CFR 30.50(b)(2) Failure of the Radiography Camera Locking Mechanism ENS 525962017-03-07T05:00:0007 March 2017 05:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Did Not Lock in the Shielded Position When Retracted ENS 515822015-12-01T10:00:0001 December 2015 10:00:00 10 CFR 30.50(b)(2) Radiography Camera Fails to Lock Source Automatically When Retracted ENS 481192012-07-02T07:45:0002 July 2012 07:45:00 10 CFR 30.50(b)(2) Unable to Retract Source Into Radiography Camera ENS 474282011-11-10T20:10:00010 November 2011 20:10:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Completely Retract ENS 474182011-11-06T07:00:0006 November 2011 07:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Lock Malfunction ENS 465332011-01-11T08:59:00011 January 2011 08:59:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 463232010-10-10T00:00:00010 October 2010 00:00:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 462332010-09-04T08:00:0004 September 2010 08:00:00 10 CFR 30.50(b)(2) Locking Mechanism Malfunction on Radiography Camera ENS 460522010-06-29T09:00:00029 June 2010 09:00:00 10 CFR 30.50(b)(2) Lock Malfunction on a Radiography Camera ENS 460512010-06-29T08:00:00029 June 2010 08:00:00 10 CFR 30.50(b)(2) Source Locking Malfunction of Radiography Camera ENS 456482010-01-22T09:00:00022 January 2010 09:00:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 456092010-01-06T10:50:0006 January 2010 10:50:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 455442009-12-07T13:30:0007 December 2009 13:30:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 455242009-11-27T17:00:00027 November 2009 17:00:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 454962009-11-13T00:30:00013 November 2009 00:30:00 10 CFR 30.50(b)(2) Failure to Fully Retract the Source of a Radiography Camera ENS 454692009-10-27T08:45:00027 October 2009 08:45:00 10 CFR 30.50(b)(2) Radiography Source Unable to Fully Retract ENS 453842009-09-27T10:00:00027 September 2009 10:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Fully Retract Into Camera ENS 437692007-11-03T23:00:0003 November 2007 23:00:00 10 CFR 30.50(b)(2) Radiography Camera Source Fails to Fully Retract Into Camera ENS 431172007-01-13T21:30:00013 January 2007 21:30:00 10 CFR 30.50(b)(2) Failure of Radiography Camera Source to Fully Retract ENS 430672006-12-28T11:30:00028 December 2006 11:30:00 10 CFR 30.50(b)(2) Failure of Radiography Camera Source to Fully Retract ENS 426822006-03-08T08:00:0008 March 2006 08:00:00 10 CFR 30.50(b)(2) Radiography Source Pigtail Disconnected from Drive Cable 2019-05-05T08:18:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_43117&oldid=427076"